WorldWideScience

Sample records for residential efficiency measures

  1. Exploring the range of energy savings likely from energy efficiency retrofit measures in Ireland's residential sector

    International Nuclear Information System (INIS)

    Dineen, D.; Ó Gallachóir, B.P.

    2017-01-01

    This paper estimates the potential energy savings in the Irish residential sector by 2020 due to the introduction of an ambitious retrofit programme. We estimate the technical energy savings potential of retrofit measures targeting energy efficiency of the space and water heating end uses of the 2011 stock of residential dwellings between 2012 and 2020. We build eight separate scenarios, varying the number of dwellings retrofitted and the depth of retrofit carried out in order to investigate the range of energy savings possible. In 2020 the estimated technical savings potential lies in the range from 1713 GWh to 10,817 GWh, but is more likely to fall within the lower end of this range, i.e. between 1700 and 4360 GWh. When rebound effects are taken into account this reduces further to 1100 GWh and 2800 GWh per annum. The purpose of this paper was to test the robustness of the NEEAP target savings for residential retrofit, i.e. 3000 GWh by 2020. We conclude that this target is technically feasible but very challenging and unlikely to be achieved based on progress to date. It will require a significant shift towards deeper retrofit measures compared to what has been achieved by previous schemes. - Highlights: • Paper estimates range of energy savings likely from Irish residential retrofit. • Achieving NEEAP target savings of 3000 GWh by 2020 is feasible but very challenging. • Likely savings of 1100–2800 GWh per annum in 2020, including rebound. • NEEAP target unlikely to be achieved based on current trends.

  2. Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stewart, James [Cadmus, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-11-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral and social sciences to influence household energy use. These may include providing households with real-time or delayed feedback about their energy use; supplying energy efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5 percent. Utilities will continue to implement residential BB programs as large-scale, randomized control trials (RCTs); however, some are now experimenting with alternative program designs that are smaller scale; involve new communication channels such as the web, social media, and text messaging; or that employ novel strategies for encouraging behavior change (for example, Facebook competitions). These programs will create new evaluation challenges and may require different evaluation methods than those currently employed to verify any savings they generate. Quasi-experimental methods, however, require stronger assumptions to yield valid savings estimates and may not measure savings with the same degree of validity and accuracy as randomized experiments.

  3. Marginal costs of intensified energy-efficiency measures in residential buildings; Grenzkosten bei forcierten Energie-Effizienzmassnahmen in Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Jakob, M.; Jochem, E. [Eidgenoessische Technische Hochschule (ETH), Centre for Energy Policy and Economics (CEPE), Zuerich (Switzerland); Kristen, K. [Eidgenoessische Technische Hochschule (ETH), Architektur und Baurealisation, Zuerich (Switzerland)

    2002-07-01

    This detailed report for the Swiss Federal Office of Energy (SFOE) examines the large potential for increasing the energy efficiency of residential buildings in Switzerland. The aims of the research project are described including investigation of costs and marginal costs for thermal insulation and efficiency measures, the updating of technical parameters for cost - efficiency characteristics on an empirical basis, a transparent presentation of cost/benefit ratios for different concepts. Another aim is to obtain a more detailed overview of costs and benefits that could be of use for planners, building owners and technology companies. The methodology used for the collection of data for the study is described. The report also takes a look at the indirect advantages of improving the thermal insulation of buildings and examines the initial economic and technical situation. A detailed review of the costs and benefits is given for the various elements of a building such as walls, floors and windows and a reference development scenario for the period 2000 -2030 is presented. Marginal cost curves for various categories of buildings are presented for thermal insulation and ventilation measures.

  4. Indoor air-quality measurements in energy-efficient residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  5. Impact of energy efficiency measures on the CO{sub 2} emissions in the residential sector, a large scale analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hens, H.; Verbeeck, G.; Verdonck, B. [Department of Civil Engineering, Laboratory for Building Physics, Leuven (Belgium)

    2000-07-01

    Like all industrialised countries, Belgium accepted to diminish its greenhouse gas emissions in the frame of the Kyoto agreement. On top of the list figures CO{sub 2}. A major emission source for CO{sub 2} is burning fossil fuels. As the residential sector accounts for 28% of the country's annual energy consumption and as this consumption mainly concerns fossil fuels, it has an equally important share in the CO{sub 2} release. Hence, at first sight, the best policy for a decrease is by improving the energy efficiency. The question to be solved, however, is which improvement could generate the reduction needed? This study discusses a methodology and comments simulations that help in answering that question. The results are not as simple as one should like. The housing stock in fact acts as a conservatory system. For the case being, the impact of energy efficient new construction on the CO{sub 2} release remains quite marginal if the period considered does not extend beyond a decade. The effect becomes significant only over a longer period, on condition that more stringent energy efficiency measures are combined with a shift from new construction to retrofit and reconstruction. Also a diminishing increase in the number of households may help in reducing energy consumption and CO{sub 2} release. (author)

  6. Dataset on energy efficiency assessment and measurement method for child-friendly space in cold residential area

    Directory of Open Access Journals (Sweden)

    Kai Ren

    2017-10-01

    Full Text Available The data related in this paper are related to “Environmental-behavior studies of sustainable construction of the third place – based on outdoor environment-behavior cross-feed symbiotic analysis and verification of selective activities” (Ren, 2017 [1]. The dataset was from a field sub-time extended investigation to children of Hohhot West Inner Mongolia Electric Power Community Residential Area in Inner Mongolia of China that belongs to cold region of ID area according to Chinese design code for buildings. This filed data provided descriptive statistics about outdoor time, behavior scale specificity, age exclusivity and self-centeredness for children in different ages (babies, preschool children, school age children. This data provided five measurement elements of child-friendly space and their weight ratio. The field data set is made publicly available to enable critical or extended analyzes.

  7. Estimation of energy efficiency of residential buildings

    Directory of Open Access Journals (Sweden)

    Glushkov Sergey

    2017-01-01

    Full Text Available Increasing energy performance of the residential buildings by means of reducing heat consumption on the heating and ventilation is the last segment in the system of energy resources saving. The first segments in the energy saving process are heat producing and transportation over the main lines and outside distribution networks. In the period from 2006 to 2013. by means of the heat-supply schemes optimization and modernization of the heating systems. using expensive (200–300 $US per 1 m though hugely effective preliminary coated pipes. the economy reached 2.7 mln tons of fuel equivalent. Considering the multi-stage and multifactorial nature (electricity. heat and water supply of the residential sector energy saving. the reasonable estimate of the efficiency of the saving of residential buildings energy should be performed in tons of fuel equivalent per unit of time.

  8. A new approach to measuring the rebound effect associated to energy efficiency improvements: An application to the US residential energy demand

    International Nuclear Information System (INIS)

    Orea, Luis; Llorca, Manuel; Filippini, Massimo

    2015-01-01

    This paper brings attention to the fact that the energy demand frontier model introduced by Filippini and Hunt (2011, 2012) is closely connected to the measurement of the so-called rebound effect associated with improvements in energy efficiency. In particular, we show that their model implicitly imposes a zero rebound effect, which contradicts most of the available empirical evidence on this issue. We relax this restrictive assumption through the modelling of a rebound-effect function that mitigates or intensifies the effect of an efficiency improvement on energy consumption. We illustrate our model with an empirical application that aims to estimate a US frontier residential aggregate energy demand function using panel data for 48 states over the period 1995 to 2011. Average values of the rebound effect in the range of 56–80% are found. Therefore, policymakers should be aware that most of the expected energy reduction from efficiency improvements may not be achieved. - Highlights: • A new approach to measuring rebound effects in energy consumption is presented. • We illustrate our proposal with an application to US residential energy demand. • Relatively large rebound effects in the range of 56–80% are found. • Energy-inefficient states tend to exhibit low rebound effects. • We identify states where energy-saving policies should be more effective

  9. Chapter 6: Residential Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dimetrosky, Scott [Apex Analytics, LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics, LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics, LLC, Boulder, CO (United States)

    2017-10-19

    Given new regulations, increased complexity in the market, and the general shift from CFLs to LEDs, this evaluation protocol was updated in 2017 to shift the focus of the protocols toward LEDs and away from CFLs and to resolve evaluation uncertainties affecting residential lighting incentive programs.

  10. Optimisation of a Swedish district heating system with reduced heat demand due to energy efficiency measures in residential buildings

    International Nuclear Information System (INIS)

    Åberg, M.; Henning, D.

    2011-01-01

    The development towards more energy efficient buildings, as well as the expansion of district heating (DH) networks, is generally considered to reduce environmental impact. But the combined effect of these two progressions is more controversial. A reduced heat demand (HD) due to higher energy efficiency in buildings might hamper co-production of electricity and DH. In Sweden, co-produced electricity is normally considered to displace electricity from less efficient European condensing power plants. In this study, a potential HD reduction due to energy efficiency measures in the existing building stock in the Swedish city Linköping is calculated. The impact of HD reduction on heat and electricity production in the Linköping DH system is investigated by using the energy system optimisation model MODEST. Energy efficiency measures in buildings reduce seasonal HD variations. Model results show that HD reductions primarily decrease heat-only production. The electricity-to-heat output ratio for the system is increased for HD reductions up to 30%. Local and global CO 2 emissions are reduced. If co-produced electricity replaces electricity from coal-fired condensing power plants, a 20% HD reduction is optimal for decreasing global CO 2 emissions in the analysed DH system. - Highlights: ► A MODEST optimisation model of the Linköping district heating system is used. ► The impact of heat demand reduction on heat and electricity production is examined. ► Model results show that heat demand reductions decrease heat-only production. ► Local and global CO 2 emissions are reduced. ► The system electricity-to-heat output increases for reduced heat demand up to 30%.

  11. Performance-based potential for residential energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Performance-based potential for residential energy efficiency

    2013-01-15

    Energy performance contracts (EPCs) have proven an effective mechanism for increasing energy efficiency in nearly all sectors of the economy since their introduction nearly 30 years ago. In the modern form, activities undertaken as part of an EPC are scoped and implemented by experts with specialized technical knowledge, financed by commercial lenders, and enable a facility owner to limit risk and investment of time and resources while receiving the rewards of improved energy performance. This report provides a review of the experiences of the US with EPCs and discusses the possibilities for the residential sector to utilize EPCs. Notably absent from the EPC market is the residential segment. Historically, research has shown that the residential sector varies in several key ways from markets segments where EPCs have proven successful, including: high degree of heterogeneity of energy use characteristics among and within households, comparatively small quantity of energy consumed per residence, limited access to information about energy consumption and savings potential, and market inefficiencies that constrain the value of efficiency measures. However, the combination of recent technological advances in automated metering infrastructure, flexible financing options, and the expansion of competitive wholesale electricity markets to include energy efficiency as a biddable supply-side resource present an opportunity for EPC-like efforts to successfully engage the residential sector, albeit following a different model than has been used in EPCs traditionally.(Author)

  12. 2011 Residential Energy Efficiency Technical Update Meeting Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-11-01

    This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

  13. Identifying Cost-Effective Residential Energy Efficiency Opportunities for the Kauai Island Utility Cooperative

    Energy Technology Data Exchange (ETDEWEB)

    Busche, S.; Hockett, S.

    2010-06-01

    This analysis is an update to the 2005 Energy Efficiency Potential Study completed by KEMA for the Kauai Island Utility Cooperative (KIUC) and identifies potential energy efficiency opportunities in the residential sector on Kauai (KEMA 2005). The Total Resource Cost (TRC) test is used to determine which of the energy efficiency measures analyzed in the KEMA report are cost effective for KIUC to include in a residential energy efficiency program. This report finds that there remains potential energy efficiency savings that could be cost-effectively incentivized through a utility residential demand-side management program on Kauai if implemented in such a way that the program costs per measure are consistent with the current residential program costs.

  14. Residential Energy Efficiency Research Planning Meeting Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2012-02-01

    This report summarizes key findings and outcomes from the U.S. Department of Energy's Building America Residential Energy Efficiency Research Planning meeting, held on October 28-29, 2011, in Washington, D.C.

  15. The performance of energy efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.

    1996-08-01

    The adequacy and durability of residential building envelope systems under actual field conditions were evaluated. A building envelope offers protection from cold, heat, moisture, wind and noise. However, they are exposed to thermal, structural, and moisture stresses and their performance can degrade over time. Envelope performance was evaluated at 20 energy efficient and four conventional, detached modern homes in Winnipeg, Canada. The three complementary measurement tools were wood moisture content (WMC) of framing members, thermographic examinations, and airtightness tests. As expected, energy efficient building envelope systems performed better than the conventional systems. No evidence of envelope degradation was found in any of the energy efficient houses. The building envelopes using polyethylene air barriers performed slightly better than those which used the airtight drywall approach, although both were considered satisfactory. WMC levels were a bit lower in the polyethylene-clad house. 1 ref., 1 tab.

  16. US residential energy demand and energy efficiency: A stochastic demand frontier approach

    International Nuclear Information System (INIS)

    Filippini, Massimo; Hunt, Lester C.

    2012-01-01

    This paper estimates a US frontier residential aggregate energy demand function using panel data for 48 ‘states’ over the period 1995 to 2007 using stochastic frontier analysis (SFA). Utilizing an econometric energy demand model, the (in)efficiency of each state is modeled and it is argued that this represents a measure of the inefficient use of residential energy in each state (i.e. ‘waste energy’). This underlying efficiency for the US is therefore observed for each state as well as the relative efficiency across the states. Moreover, the analysis suggests that energy intensity is not necessarily a good indicator of energy efficiency, whereas by controlling for a range of economic and other factors, the measure of energy efficiency obtained via this approach is. This is a novel approach to model residential energy demand and efficiency and it is arguably particularly relevant given current US energy policy discussions related to energy efficiency.

  17. Energy efficient residential house wall system

    International Nuclear Information System (INIS)

    Aldawi, Fayez; Date, Abhijit; Alam, Firoz; Khan, Iftekhar; Alghamdi, Mohammed

    2013-01-01

    The energy consumption and greenhouse gas emission by the residential housing sector are considered to be one of the largest in economically developed countries. The larger energy consumption and greenhouse gas emission not only put additional pressure on finite fossil fuel resources but also cause global warming and climate change. Additionally, the residential housing sector will be consuming more energy as the house demand and average house floor area are progressively increasing. With currently used residential house wall systems, it is hard to reduce energy consumption for ongoing house space heating and cooling. A smart house wall envelope with optimal thermal masses and insulation materials is vital for reducing our increasing energy consumption. The major aim of this study is to investigate thermal performance and energy saving potential of a new house wall system for variable climate conditions. The thermal performance modelling was carried out using commercially developed software AccuRate ® . The findings indicate that a notable energy savings can be accomplished if a smart house wall system is used. -- Highlights: • Smart house wall system. • Thermal performance modelling and star energy rating. • Energy savings and greenhouse gas reduction

  18. Residential Electrostatic Precipitator - Performance at efficient and poor combustion conditions

    Energy Technology Data Exchange (ETDEWEB)

    Baefver, Linda; Yngvesson, Johan; Niklasson, Fredrik

    2012-07-01

    The performance of a pilot residential electrostatic precipitator R{sub E}SP (Applied Plasma Physics AS), was investigated at laboratory. Measurements of TSP (Total Suspended Particles), content of organic and elemental carbon, and mass size distribution of particles upstream and downstream of ESP were performed. Values for PM1 (particles < 1 {mu}m) were calculated from the particle size distributions. Concentrations and size distributions with respect to particle numbers were measured in separate tests. Gas concentrations, temperatures and boiler parameters were also measured. The TSP concentrations upstream of the R{sub E}SP were varied in range of 15-390 mg/m{sub N}{sup 3}. Up to concentrations of about 300 mg/m{sub N}{sup 3}, the TSP-concentrations out from the ESP were less than 20 mg/m{sub N}{sup 3}, which is well below the German emission limit for wood stoves. The removal efficiencies with respect to mass were about 87% at efficient combustion and 93% at poor combustion. Corresponding values with respect to number concentrations were about 97% at efficient combustion and almost 99% at poor combustion. The better performance at poor combustion may be explained by lower flue gas temperature, leading to longer residence time in the ESP. High removal efficiencies were also found with respect to particulate organic and elemental carbon.

  19. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...... the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  20. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Heating and Cooling Equipment-Efficiency Upgrade Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jacobson, David [Jacobson Energy Research, Providence, RI (United States); Metoyer, Jarred [DNV GL, Madison, WI (United States)

    2017-11-02

    The specific measure described here involves improving the overall efficiency in air-conditioning systems as a whole (compressor, evaporator, condenser, and supply fan). The efficiency rating is expressed as the energy efficiency ratio (EER), seasonal energy efficiency ratio (SEER), and integrated energy efficiency ratio (IEER). The higher the EER, SEER or IEER, the more efficient the unit is.

  1. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jacobson, David [Jacobson Energy Research, Providence, RI (United States)

    2017-09-01

    The high-efficiency boiler and furnace measure produces gas heating savings resulting from installation of more energy-efficient heating equipment in a residence. Such equipment, which ranges in size from 60 kBtu/hr to 300 kBtu/hr, is installed primarily in single-family homes and multifamily buildings with individual heating systems for each dwelling unit. This protocol does not cover integrated heating and water heating units which can be used in lieu of space heating only equipment.

  2. An innovative educational program for residential energy efficiency. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Laquatra, J.; Chi, P.S.K.

    1996-09-01

    Recognizing the importance of energy conservation, under sponsorship of the US Department of Energy, Cornell University conducted a research and demonstration project entitled An Innovative Educational Program for Residential Energy Efficiency. The research project examined the amount of residential energy that can be saved through changes in behavior and practices of household members. To encourage these changes, a workshop was offered to randomly-selected households in New York State. Two surveys were administered to household participants (Survey 1 and Survey 2, Appendix A) and a control group; and a manual was developed to convey many easy but effective ways to make a house more energy efficient (see Residential Manual, Appendix B). Implementing methods of energy efficiency will help reduce this country`s dependence on foreign energy sources and will also reduce the amount of money that is lost on inefficient energy use. Because Cornell Cooperative Extension operates as a component of the land-grant university system throughout the US, the results of this research project have been used to develop a program that can be implemented by the Cooperative Extension Service nationwide. The specific goals and objectives for this project will be outlined, the population and sample for the research will be described, and the instruments utilized for the survey will be explained. A description of the workshop and manual will also be discussed. This report will end with a summary of the results from this project and any observed changes and/or recommendations for future surveys pertaining to energy efficiency.

  3. A Method for Determining Optimal Residential Energy Efficiency Packages

    Energy Technology Data Exchange (ETDEWEB)

    Polly, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gestwick, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bianchi, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Anderson, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Horowitz, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Judkoff, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-04-01

    This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location.

  4. Exploring efficacy of residential energy efficiency programs in Florida

    Science.gov (United States)

    Taylor, Nicholas Wade

    Electric utilities, government agencies, and private interests in the U.S. have committed and continue to invest substantial resources in the pursuit of energy efficiency and conservation through demand-side management (DSM) programs. Program investments, and the demand for impact evaluations that accompany them, are projected to grow in coming years due to increased pressure from state-level energy regulation, costs and challenges of building additional production capacity, fuel costs and potential carbon or renewable energy regulation. This dissertation provides detailed analyses of ex-post energy savings from energy efficiency programs in three key sectors of residential buildings: new, single-family, detached homes; retrofits to existing single-family, detached homes; and retrofits to existing multifamily housing units. Each of the energy efficiency programs analyzed resulted in statistically significant energy savings at the full program group level, yet savings for individual participants and participant subgroups were highly variable. Even though savings estimates were statistically greater than zero, those energy savings did not always meet expectations. Results also show that high variability in energy savings among participant groups or subgroups can negatively impact overall program performance and can undermine marketing efforts for future participation. Design, implementation, and continued support of conservation programs based solely on deemed or projected savings is inherently counter to the pursuit of meaningful energy conservation and reductions in greenhouse gas emissions. To fully understand and optimize program impacts, consistent and robust measurement and verification protocols must be instituted in the design phase and maintained over time. Furthermore, marketing for program participation must target those who have the greatest opportunity for savings. In most utility territories it is not possible to gain access to the type of large scale

  5. Analysis of Installed Measures and Energy Savings for Single-Family Residential Better Buildings Projects

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Polly, B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-04-30

    This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.

  6. Energy efficiency in U.S. residential rental housing: Adoption rates and impact on rent

    International Nuclear Information System (INIS)

    Im, Jongho; Seo, Youngme; Cetin, Kristen S.; Singh, Jasmeet

    2017-01-01

    Highlights: •Rental units listings collected and analyzed for 10 U.S. cities. •Energy efficient features included in 5.3–21.6% of rental units in each city. •The most common efficient features are lighting and appliance upgrades. •Propensity score matching and conditional mean comparison methods used. •Generally, energy efficient features increases the units’ rent, overall from 6% to 14%. -- Abstract: For 118 million residential housing units in the U.S., there is currently a gap between the potential energy savings that can be achieved through the use of existing energy efficiency technologies, and the actual level of energy savings realized, particularly for the 37% of housing units that are considered residential rental properties. Additional quantifiable benefits are needed beyond energy savings to help further motivate residential property owners to invest in energy efficiency upgrades. This research focuses on assessing the adoption of energy efficient upgrades in U.S. residential housing and the impact on rental prices. Ten U.S. cities are chosen for analysis; these cities vary in size across multiple climate zones, and represent a diverse set of housing market conditions. Data was collected for over 159,000 rental property listings, their characteristics, and their energy efficiency measures listed in rental housing postings across each city. Following an extensive data quality control process, over thirty different types energy efficient features were identified. The level of adoption was determined for each city, ranging from 5.3% to 21.6%. Efficient lighting and appliances were among the most common, with many features doubling as energy efficient and other desirable aesthetic or comfort improvements. Then using propensity score matching and conditional mean comparison methods, the relative impact on rent charged in each city was calculated, which ranged from a 6% to 14.1% increase in rent for properties with energy efficient features

  7. Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

    Energy Technology Data Exchange (ETDEWEB)

    Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

    2011-04-01

    Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

  8. Impacts of US federal energy efficiency standards for residential appliances

    International Nuclear Information System (INIS)

    Meyers, S.; McMahon, J.E.; McNeil, M.; Liu, X.

    2003-01-01

    This study estimated energy, environmental, and consumer impacts of US federal residential energy efficiency standards taking effect in the 1988-2007 period. These standards have been the subject of in-depth analyses conducted as part of the US Department of Energy's (DOE's) standards rulemaking process. This study drew on those analyses, but updated key data and developed a common framework and assumptions for all of the products. We estimate that the considered standards will reduce residential primary energy consumption and carbon dioxide (CO 2 ) emissions by 8-9% in 2020 compared to the levels expected without any standards. The standards will save a cumulative total of 26-32 EJ (25-30 quads) by the year 2015, and 63 EJ (60 quads) by 2030. The estimated cumulative net present value of consumer benefit amounts to nearly US$80 billion by 2015, and grows to US$130 billion by 2030. The overall benefit/cost ratio of cumulative consumer impacts in the 1987-2050 period is 2.75:1. The cumulative cost of the DOE's program to establish and implement the standards is in the range of US$200-US$250 million. (author)

  9. Impact of energy policy instruments on the estimated level of underlying energy efficiency in the EU residential sector

    International Nuclear Information System (INIS)

    Filippini, Massimo; Hunt, Lester C.; Zorić, Jelena

    2014-01-01

    The promotion of energy efficiency is seen as one of the top priorities of EU energy policy (EC, 2010). In order to design and implement effective energy policy instruments, it is necessary to have information on energy demand price and income elasticities in addition to sound indicators of energy efficiency. This research combines the approaches taken in energy demand modelling and frontier analysis in order to econometrically estimate the level of energy efficiency for the residential sector in the EU-27 member states for the period 1996 to 2009. The estimates for the energy efficiency confirm that the EU residential sector indeed holds a relatively high potential for energy savings from reduced inefficiency. Therefore, despite the common objective to decrease ‘wasteful’ energy consumption, considerable variation in energy efficiency between the EU member states is established. Furthermore, an attempt is made to evaluate the impact of energy-efficiency measures undertaken in the EU residential sector by introducing an additional set of variables into the model and the results suggest that financial incentives and energy performance standards play an important role in promoting energy efficiency improvements, whereas informative measures do not have a significant impact. - Highlights: • The level of energy efficiency of the EU residential sector is estimated. • Considerable potential for energy savings from reduced inefficiency is established. • The impact of introduced energy-efficiency policy measures is also evaluated. • Financial incentives are found to promote energy efficiency improvements. • Energy performance standards also play an important role

  10. Energy efficiency standards for residential and commercial equipment: Additional opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Greg; McNeil, Michael; Iyer, Maithili; Meyers, Steve; McMahon, Jim

    2004-08-02

    Energy efficiency standards set minimum levels of energy efficiency that must be met by new products. Depending on the dynamics of the market and the level of the standard, the effect on the market for a given product may be small, moderate, or large. Energy efficiency standards address a number of market failures that exist in the buildings sector. Decisions about efficiency levels often are made by people who will not be responsible for the energy bill, such as landlords or developers of commercial buildings. Many buildings are occupied for their entire lives by very temporary owners or renters, each unwilling to make long-term investments that would mostly reward subsequent users. And sometimes what looks like apathy about efficiency merely reflects inadequate information or time invested to evaluate it. In addition to these sector-specific market failures, energy efficiency standards address the endemic failure of energy prices to incorporate externalities. In the U.S., energy efficiency standards for consumer products were first implemented in California in 1977. National standards became effective starting in 1988. By the end of 2001, national standards were in effect for over a dozen residential appliances, as well as for a number of commercial sector products. Updated standards will take effect in the next few years for several products. Outside the U.S., over 30 countries have adopted minimum energy performance standards. Technologies and markets are dynamic, and additional opportunities to improve energy efficiency exist. There are two main avenues for extending energy efficiency standards. One is upgrading standards that already exist for specific products. The other is adopting standards for products that are not covered by existing standards. In the absence of new and upgraded energy efficiency standards, it is likely that many new products will enter the stock with lower levels of energy efficiency than would otherwise be the case. Once in the stock

  11. The effect of economic factors and energy efficiency programs on residential electricity consumption

    Science.gov (United States)

    Sakai, Mihoko

    Many countries have implemented policies to correct market and behavioral failures that lead to inefficient energy use. It is important to know what factors and policies can effectively overcome such failures and improve energy efficiency; however, a comprehensive analysis has been difficult because of data limitations. Using state scores compiled by American organizations recently, and adopting fixed-effects regression models, I analyze the joint impacts of relevant factors and policy programs on residential electricity consumption in each U.S. state. The empirical results reveal that increases in electricity price have small and negative effects, and increases in personal income have positive effects on residential electricity sales per capita (a measure of energy efficiency). The results suggest that it may take time for economic factors to affect electricity sales. The effects of personal income suggest the difficulty of controlling residential electricity consumption; however, they also imply that there is some room in households to reduce electricity use. The study also finds that programs and budgets of several policies seem to be associated with electricity sales. The estimates from a model including interaction terms suggest the importance of including multiple policies when analyzing and designing policies to address electricity efficiency. The results also imply the possibility of rebound effects of some policies, whereby improvements in energy efficiency lead to increases in energy consumption due to the associated lower per unit cost. Future studies should analyze both short-term and long-term effects of economic factors and policies, based on improved and accumulated time series and panel data, in order to design more effective policies for improving residential electricity efficiency.

  12. Summary of Gaps and Barriers for Implementing Residential Building Energy Efficiency Strategies

    Energy Technology Data Exchange (ETDEWEB)

    2010-08-01

    This report presents the key gaps and barriers to implementing residential energy efficiency strategies in the U.S. market, as identified in sessions at the U.S. Department of Energy's Building America 2010 Residential Energy Efficiency Meeting held in Denver, Colorado, on July 20-22, 2010.

  13. 2011 Residential Energy Efficiency Technical Update Meeting Summary Report: Denver, Colorado - August 9-11, 2011

    Energy Technology Data Exchange (ETDEWEB)

    2011-11-01

    This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

  14. Field performance of energy-efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Prowskiw, G.

    1992-05-01

    The air tightness of 24 new houses was measured on a regular basis over periods up to three years to evaluate the structures' air barrier systems and to study the possibility of air barrier degradation, as would be indicated by an increase in the measured leakage rate. Ten of the houses were built with the polyethylene air barrier system and 14 using an early version of the Airtight Drywall Approach (ADA). The 24 project houses were architecturally similar and of approximately equal size and general layout. The airtightness of the polyethylene air barrier houses was found to remain stable over their respective monitoring periods. It was concluded that no evidence could be found to indicate polyethylene is unsuited for use as an air barrier material in residential construction. Although 2 of the 10 houses demonstrated possible, albeit slight, evidence of airtightness degradation, the magnitude of these changes was small and judged not to be of practical significance. All but one of the polyethylene houses met the airtightness requirements of the R-2000 program at the end of their monitoring periods. The project houses with the lowest measured leakage rates were those built with the double wall system and polyethylene barriers. The study also found that the airtightness of the 14 ADA houses remained stable during the monitoring period and it was concluded that no evidence could be found to indicate that the ADA system is unsuited for use in residential construction. Although 6 of the 15 houses displayed possible, but also slight, evidence of airtightness degradation, the magnitude of the changes was small and not of practical significance. All 14 houses met the airtightness requirements of the R-2000 program at the end of their respective monitoring periods. 19 refs., 191 figs., 39 tabs.

  15. Factors influencing energy efficiency investments in existing Swedish residential buildings

    International Nuclear Information System (INIS)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna

    2010-01-01

    We used the data from a survey conducted in 2008 of 3,000 owners of detached houses to analyse the factors that influence the adoption of investment measures to improve the energy efficiency of their buildings. For the majority of Swedish homeowners, it was important to reduce their household energy use, and most of them undertook no-cost measures as compared to investment measures. Personal attributes such as income, education, age and contextual factors, including age of the house, thermal discomfort, past investment, and perceived energy cost, influence homeowners' preference for a particular type of energy efficiency measure. The implications for promoting the implementation of energy efficiency investment measures are discussed.

  16. Residential air-conditioner usage in China and efficiency standardization

    International Nuclear Information System (INIS)

    Wu, Jianghong; Liu, Chaopeng; Li, Hongqi; Ouyang, Dong; Cheng, Jianhong; Wang, Yuanxia; You, Shaofang

    2017-01-01

    Determining the real energy consumption and usage pattern of a room air-conditioner (RAC) are important issues from the point of view of both RAC design and evaluation of its energy efficiency. An air-conditioner's running time is fundamental data for the calculation of SEER and APF values. Therefore, in 2010, a nationwide investigation of RAC usage was conducted and 400 selected air-conditioning-units were monitored for a full year to obtain data on their cooling and heating usage. Two running time curves (cooling and heating) were obtained for the air-conditioners as a function of outdoor air temperatures using statistical analysis. The results show that the 27–30 °C temperature range accounts for more than 52% of the cooling time. Conversely, the 0–8 °C temperature range is associated with more than 75% of the heating time. The research presented in this paper has significantly contributed to China's new variable-speed RAC efficiency standard (GB21455-2013). It also has far-reaching implications for both the air-conditioner industry and energy policy in China due to its different method of calculating energy efficiency. - Highlights: • A nationwide survey to realize China's residential air-conditions usage behaviors. • Air-conditioner running time-environment temperature curves are obtained. • The peak heating demand and peak cooling demand happen at 28 °C and 4 °C, respectively. • The temperature of 27 °C–30 °C accounts for over 52% refrigeration time. • The temperature of 0 °C–8 °C occupies more than 75% heating time.

  17. Characterizing Synergistic Water and Energy Efficiency at the Residential Scale Using a Cost Abatement Curve Approach

    Science.gov (United States)

    Stillwell, A. S.; Chini, C. M.; Schreiber, K. L.; Barker, Z. A.

    2015-12-01

    Energy and water are two increasingly correlated resources. Electricity generation at thermoelectric power plants requires cooling such that large water withdrawal and consumption rates are associated with electricity consumption. Drinking water and wastewater treatment require significant electricity inputs to clean, disinfect, and pump water. Due to this energy-water nexus, energy efficiency measures might be a cost-effective approach to reducing water use and water efficiency measures might support energy savings as well. This research characterizes the cost-effectiveness of different efficiency approaches in households by quantifying the direct and indirect water and energy savings that could be realized through efficiency measures, such as low-flow fixtures, energy and water efficient appliances, distributed generation, and solar water heating. Potential energy and water savings from these efficiency measures was analyzed in a product-lifetime adjusted economic model comparing efficiency measures to conventional counterparts. Results were displayed as cost abatement curves indicating the most economical measures to implement for a target reduction in water and/or energy consumption. These cost abatement curves are useful in supporting market innovation and investment in residential-scale efficiency.

  18. Economic and environmental impacts of community-based residential building energy efficiency investment

    International Nuclear Information System (INIS)

    Choi, Jun-Ki; Morrison, Drew; Hallinan, Kevin P.; Brecha, Robert J.

    2014-01-01

    A systematic framework for evaluating the local economic and environmental impacts of investment in building energy efficiency is developed. Historical residential building energy data, community-wide economic input–output data, and emission intensity data are utilized. The aim of this study is to show the comprehensive insights and connection among achieving variable target reductions for a residential building energy use, economic and environmental impacts. Central to this approach for the building energy reduction goal is the creation of individual energy models for each building based upon historical energy data and available building data. From these models, savings estimates and cost implications can be estimated for various conservation measures. A ‘worst to first’ (WF) energy efficient investment strategy is adopted to optimize the level of various direct, indirect, and induced economic impacts on the local community. This evaluation helps to illumine opportunities to establish specific energy reduction targets having greatest economic impact in the community. From an environmental perspective, short term economy-wide CO 2 emissions increase because of the increased community-wide economic activities spurred by the production and installation of energy efficiency measures, however the resulting energy savings provide continuous CO 2 reduction for various target savings. - Highlights: • WF energy efficient strategy helps to optimize various level of economic impacts. • Greatest community benefits are achieved from specific energy reduction targets. • Community-wide economic impacts vary for different energy conservation measures

  19. Residential energy efficiency: Progress since 1973 and future potential

    Science.gov (United States)

    Rosenfeld, Arthur H.

    1985-11-01

    Today's 85 million U.S. homes use 100 billion of fuel and electricity (1150/home). If their energy intensity (resource energy/ft2) were still frozen at 1973 levels, they would use 18% more. With well-insulated houses, need for space heat is vanishing. Superinsulated Saskatchewan homes spend annually only 270 for space heat, 150 for water heat, and 400 for appliances, yet they cost only 2000±1000 more than conventional new homes. The concept of Cost of Conserved Energy (CCE) is used to rank conservation technologies for existing and new homes and appliances, and to develop supply curves of conserved energy and a least cost scenario. Calculations are calibrated with the BECA and other data bases. By limiting investments in efficiency to those whose CCE is less than current fuel and electricity prices, the potential residential plus commercial energy use in 2000 AD drops to half of that estimated by DOE, and the number of power plants needed drops by 200. For the whole buildings sector, potential savings by 2000 are 8 Mbod (worth 50B/year), at an average CCE of 10/barrel.

  20. Measuring urban tree loss dynamics across residential landscapes.

    Science.gov (United States)

    Ossola, Alessandro; Hopton, Matthew E

    2018-01-15

    The spatial arrangement of urban vegetation depends on urban morphology and socio-economic settings. Urban vegetation changes over time because of human management. Urban trees are removed due to hazard prevention or aesthetic preferences. Previous research attributed tree loss to decreases in canopy cover. However, this provides little information about location and structural characteristics of trees lost, as well as environmental and social factors affecting tree loss dynamics. This is particularly relevant in residential landscapes where access to residential parcels for field surveys is limited. We tested whether multi-temporal airborne LiDAR and multi-spectral imagery collected at a 5-year interval can be used to investigate urban tree loss dynamics across residential landscapes in Denver, CO and Milwaukee, WI, covering 400,705 residential parcels in 444 census tracts. Position and stem height of trees lost were extracted from canopy height models calculated as the difference between final (year 5) and initial (year 0) vegetation height derived from LiDAR. Multivariate regression models were used to predict number and height of tree stems lost in residential parcels in each census tract based on urban morphological and socio-economic variables. A total of 28,427 stems were lost from residential parcels in Denver and Milwaukee over 5years. Overall, 7% of residential parcels lost one stem, averaging 90.87 stems per km 2 . Average stem height was 10.16m, though trees lost in Denver were taller compared to Milwaukee. The number of stems lost was higher in neighborhoods with higher canopy cover and developed before the 1970s. However, socio-economic characteristics had little effect on tree loss dynamics. The study provides a simple method for measuring urban tree loss dynamics within and across entire cities, and represents a further step toward high resolution assessments of the three-dimensional change of urban vegetation at large spatial scales. Published by

  1. Factors influencing energy efficiency investments in existing Swedish residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna [Ecotechnology, Mid Sweden University, SE-83125 Oestersund (Sweden)

    2010-06-15

    We used the data from a survey conducted in 2008 of 3,000 owners of detached houses to analyse the factors that influence the adoption of investment measures to improve the energy efficiency of their buildings. For the majority of Swedish homeowners, it was important to reduce their household energy use, and most of them undertook no-cost measures as compared to investment measures. Personal attributes such as income, education, age and contextual factors, including age of the house, thermal discomfort, past investment, and perceived energy cost, influence homeowners' preference for a particular type of energy efficiency measure. The implications for promoting the implementation of energy efficiency investment measures are discussed. (author)

  2. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    generation characteristics, heat transfer and thermal dynamics of sustainable residential buildings and load scheduling potentials of household appliances with associated constraints. Through various simulation studies under different working scenarios with real data, different system constraints and user...

  3. Efficient and inefficient aspects of residential energy behaviour: What are the policy instruments for change?

    Energy Technology Data Exchange (ETDEWEB)

    Linden, Anna-Lisa [Department of Sociology, Lund University, P.O. Box 114, SE-221 00 Lund (Sweden)]. E-mail: anna-lisa.linden@soc.lu.se; Carlsson-Kanyama, Annika [Department of Environmental Strategies Research, FOI, SE-172 90 Stockholm (Sweden); Eriksson, Bjoern [Department of Environmental Strategies Research, FOI, SE-172 90 Stockholm (Sweden)

    2006-09-15

    The empirical part of this study is based on a survey of 600 Swedish households and a number of interviews where questions about residential energy behaviour and possible policy instruments for change were raised. The study provides insight into current behavioural patterns and gives a bottom-up perspective on the realistic perspective potentials for change and ways to achieve them. Residential energy use accounts for a fifth of the total in Northern nations and patterns of behaviour may influence levels of energy use to the same extent as choice of appliances. The study revealed those behavioural patterns that are efficient and those that need to be improved for energy conservation. Several policy instruments for change were identified in the study and they include combinations of information, economic measures, administrative measures and more user friendly technology as well as equipment with sufficient esthetic quality. Policy instruments that have fostered energy efficient behaviour in Sweden include the massive information campaigns during the oil crises in the 1970s as well as energy labelling of appliances. Still, many households are 'energy-unaware' and several energy efficient behaviours are motivated not by energy conservation concern but of a perceived lack of time. This shows that it is important to have a broad perspective in energy conservation, to evaluate trends and to use policy instruments timely to support or discourage them.

  4. Efficient and inefficient aspects of residential energy behaviour: What are the policy instruments for change?

    International Nuclear Information System (INIS)

    Linden, Anna-Lisa; Carlsson-Kanyama, Annika; Eriksson, Bjoern

    2006-01-01

    The empirical part of this study is based on a survey of 600 Swedish households and a number of interviews where questions about residential energy behaviour and possible policy instruments for change were raised. The study provides insight into current behavioural patterns and gives a bottom-up perspective on the realistic perspective potentials for change and ways to achieve them. Residential energy use accounts for a fifth of the total in Northern nations and patterns of behaviour may influence levels of energy use to the same extent as choice of appliances. The study revealed those behavioural patterns that are efficient and those that need to be improved for energy conservation. Several policy instruments for change were identified in the study and they include combinations of information, economic measures, administrative measures and more user friendly technology as well as equipment with sufficient esthetic quality. Policy instruments that have fostered energy efficient behaviour in Sweden include the massive information campaigns during the oil crises in the 1970s as well as energy labelling of appliances. Still, many households are 'energy-unaware' and several energy efficient behaviours are motivated not by energy conservation concern but of a perceived lack of time. This shows that it is important to have a broad perspective in energy conservation, to evaluate trends and to use policy instruments timely to support or discourage them

  5. Evaluation of flow hood measurements for residential register flows; TOPICAL

    International Nuclear Information System (INIS)

    Walker, I.S.; Wray, C.P.; Dickerhoff, D.J.; Sherman, M.H.

    2001-01-01

    Flow measurement at residential registers using flow hoods is becoming more common. These measurements are used to determine if the HVAC system is providing adequate comfort, appropriate flow over heat exchangers and in estimates of system energy losses. These HVAC system performance metrics are determined by using register measurements to find out if individual rooms are getting the correct airflow, and in estimates of total air handler flow and duct air leakage. The work discussed in this paper shows that commercially available flow hoods are poor at measuring flows in residential systems. There is also evidence in this and other studies that flow hoods can have significant errors even when used on the non-residential systems they were originally developed for. The measurement uncertainties arise from poor calibrations and the sensitivity of exiting flow hoods to non-uniformity of flows entering the device. The errors are usually large-on the order of 20% of measured flow, which is unacceptably high for most applications. Active flow hoods that have flow measurement devices that are insensitive to the entering airflow pattern were found to be clearly superior to commercially available flow hoods. In addition, it is clear that current calibration procedures for flow hoods may not take into account any field application problems and a new flow hood measurement standard should be developed to address this issue

  6. Energy and exergy utilization efficiencies in the Japanese residential/commercial sectors

    International Nuclear Information System (INIS)

    Kondo, Kumiko

    2009-01-01

    Unlike the manufacturing sector, the residential/commercial sectors of Japan struggle to meet their environmental requirements. For instance, their CO 2 emission levels have increased tremendously since 1990. This research estimates energy and 'exergy (available energy)' efficiencies in Japan's residential/commercial sectors during the period 1990-2006. Since an exergy analysis reveals 'available energy losses', it is an effective tool to achieve sustainable societies. The primary objective of this paper is to examine the potential for advancing the 'true' energy efficiency in Japan's residential/commercial sectors-by observing energy and exergy efficiency disparities. The results show large differences between the overall energy and exergy efficiencies in the residential (60.12%, 6.33%)/commercial sectors (51.78%, 5.74%) in 2006. This implies great potential for energy savings in both sectors. Furthermore, this research suggests that the residential sector may face more difficulties than the commercial sector, although the latter appears to be less energy-efficient, according to recent statistics. This is because the disparity between energy and exergy efficiencies has expanded in the residential sector since 2000. This study illustrates the importance of exergy analyses in promoting sustainable energy policies and new adaptation strategies.

  7. Measuring radon source magnitude in residential buildings

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Nero, A.V.

    1981-08-01

    A description is given of procedures used in residences for rapid grab-sample and time-dependent measurements of the air-exchange rate and radon concentration. The radon source magnitude is calculated from the results of simultaneous measurements of these parameters. Grab-sample measurements in three survey groups comprising 101 US houses showed the radon source magnitude to vary approximately log-normally with a geometric mean of 0.37 and a range of 0.01 to 6.0 pCi 1 -1 h -1 . Successive measurements in six houses in the northeastern United States showed considerable variability in source magnitude within a given house. In two of these houses the source magnitude showed a strong correlation with the air-exchange rate, suggesting that soil gas influx can be an important transport process for indoor radon

  8. Measure Guideline. High Efficiency Natural Gas Furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Rose, W. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States)

    2012-10-01

    This measure guideline covers installation of high-efficiency gas furnaces, including: when to install a high-efficiency gas furnace as a retrofit measure; how to identify and address risks; and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation of information provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

  9. Measure Guideline: High Efficiency Natural Gas Furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L.; Rose, W.

    2012-10-01

    This Measure Guideline covers installation of high-efficiency gas furnaces. Topics covered include when to install a high-efficiency gas furnace as a retrofit measure, how to identify and address risks, and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation of information provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

  10. 78 FR 9631 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2013-02-11

    ... Efficiency Program for Consumer Products: Energy Conservation Standards for Residential Boilers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of public meeting.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J...

  11. A Case Study in Market Transformation for Residential Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Building Technologies Office

    2017-09-01

    This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.

  12. Prioritizing investment in residential energy efficiency and renewable energy-A case study for the U.S. Midwest

    International Nuclear Information System (INIS)

    Brecha, R.J.; Mitchell, A.; Hallinan, K.; Kissock, K.

    2011-01-01

    Residential building energy use is an important contributor to greenhouse gas emissions and in the United States represents about 20% of total energy consumption. A number of previous macro-scale studies of residential energy consumption and energy-efficiency improvements are mainly concerned with national or international aggregate potential savings. In this paper we look into the details of how a collection of specific homes in one region might reduce energy consumption and carbon emissions, with particular attention given to some practical limits to what can be achieved by upgrading the existing residential building stock. Using a simple model of residential, single-family home construction characteristics, estimates are made for the efficacy of (i) changes to behavioral patterns that do not involve building shell modifications; (ii) straightforward air-infiltration mitigation measures, and (iii) insulation measures. We derive estimates of net lifetime savings resulting from these measures, in terms of energy, carbon emissions and dollars. This study points out explicitly the importance of local and regional patterns in decision-making about what fraction of necessary regional or national emissions reduction might be accomplished through energy-efficiency measures and how much might need to concentrate more heavily on renewable or other carbon-free sources of energy. - Highlights: → Macro-scale estimates of building energy efficiency measures are not adequate for implementing policy decisions. → Measures taken to implement building energy efficiency upgrades will likely encounter practical limits given the existing building stock. → Energy efficiency measures combined with increases in renewable energy use will be necessary for climate change mitigation. → Regional and local variations in building energy use must be taken into account in energy and climate policy.

  13. Measuring efficiency in logistics

    Directory of Open Access Journals (Sweden)

    Milan Milovan Andrejić

    2013-06-01

    Full Text Available Dynamic market and environmental changes greatly affect operating of logistics systems. Logistics systems have to realize their activities and processes in an efficient way. The main objective of this paper is to analyze different aspects of efficiency measurement in logistics and to propose appropriate models of measurement. Measuring efficiency in logistics is a complex process that requires consideration of all subsystems, processes and activities as well as the impact of various financial, operational, environmental, quality and other factors. The proposed models have a basis in the Data Envelopment Analysis method. They could help managers in decision making and corrective actions processes. The tests and results of the model show the importance of input and output variables selection.

  14. Energy efficiency to reduce residential electricity and natural gas use under climate change.

    Science.gov (United States)

    Reyna, Janet L; Chester, Mikhail V

    2017-05-15

    Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.

  15. Maximizing Information from Residential Measurements of Volatile Organic Compounds

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Li, Na [Berkeley Analytical Associates, Richmond, CA (United States); Hodgson, Alfred [Berkeley Analytical Associates, Richmond, CA (United States); Offermann, Francis [Indoor Environmental Engineering, San Francisco, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-02-01

    Continually changing materials used in home construction and finishing can introduce new chemicals or changes in the VOC profile in residential air and the trend towards tighter homes can lead to higher exposure concentrations for many indoor sources. However, the complex mixture of VOCs in residential air makes it difficult to discover emerging contaminants and/or trends in pollutant profiles. The purpose of this study is to prepare a comprehensive library of chemicals found in homes, along with a semi-quantitative approach to maximize the information gained from VOC measurements. We carefully reviewed data from 108 new California homes and identified 238 individual compounds. The majority of the identified VOCs originated indoors. Only 31% were found to have relevant health based exposure guidelines and less than 10% had a chronic reference exposure level (CREL). The finding highlights the importance of extending IAQ studies to include a wider range of VOCs

  16. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In this paper, an effective energy management system (EMS) for application in integrated building and microgrid system is introduced and implemented as a multi-objective optimization problem. The proposed architecture covers different key modelling aspects such as distributed heat and electricity......’s objectives, the effectiveness and applicability of the proposed model is studied and validated compared to the existing residential EMSs. The simulation results demonstrate that the proposed EMS has the capability not only to conserve energy in sustainable homes and microgrid system and to reduce energy...

  17. 76 FR 63211 - Energy Efficiency Program: Test Procedures for Residential Water Heaters, Direct Heating...

    Science.gov (United States)

    2011-10-12

    ... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2011-BT-TP-0042] RIN 1904-AC53 Energy Efficiency Program: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool Heaters AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Request for...

  18. Exploring utility organization electricity generation, residential electricity consumption, and energy efficiency: A climatic approach

    International Nuclear Information System (INIS)

    Craig, Christopher A.; Feng, Song

    2017-01-01

    Highlights: • Study examined impact of electricity fuel sources and consumption on emissions. • 97.2% of variability in emissions explained by coal and residential electricity use. • Increasing cooling degree days significantly related to increased electricity use. • Effectiveness of state-level energy efficiency programs showed mixed results. - Abstract: This study examined the impact of electricity generation by fuel source type and electricity consumption on carbon emissions to assess the role of climatic variability and energy efficiency (EE) in the United States. Despite high levels of greenhouse gas emissions, residential electricity consumption continues to increase in the United States and fossil fuels are the primary fuel source of electricity generation. 97.2% of the variability in carbon emissions in the electricity industry was explained by electricity generation from coal and residential electricity consumption. The relationships between residential electricity consumption, short-term climatic variability, long-term climatic trends, short-term reduction in electricity from EE programs, and long-term trends in EE programs was examined. This is the first study of its nature to examine these relationships across the 48 contiguous United States. Inter-year and long-term trends in cooling degree days, or days above a baseline temperature, were the primary climatic drivers of residential electricity consumption. Cooling degree days increased across the majority of the United States during the study period, and shared a positive relationship with residential electricity consumption when findings were significant. The majority of electricity reduction from EE programs was negatively related to residential electricity consumption where findings were significant. However, the trend across the majority of states was a decrease in electricity reduction from EE while residential electricity consumption increased. States that successfully reduced consumption

  19. Complex analysis of energy efficiency in operated high-rise residential building: Case study

    Directory of Open Access Journals (Sweden)

    Korniyenko Sergey

    2018-01-01

    Full Text Available Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects. Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.

  20. Complex analysis of energy efficiency in operated high-rise residential building: Case study

    Science.gov (United States)

    Korniyenko, Sergey

    2018-03-01

    Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects). Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.

  1. Analyzing Residential End-Use Energy Consumption Data to Inform Residential Consumer Decisions and Enable Energy Efficiency Improvements

    Science.gov (United States)

    Carlson, Derrick R.

    While renewable energy is in the process of maturing, energy efficiency improvements may provide an opportunity to reduce energy consumption and consequent greenhouse gas emissions to bridge the gap between current emissions and the reductions necessary to prevent serious effects of climate change and will continue to be an integral part of greenhouse gas emissions policy moving forward. Residential energy is a largely untapped source of energy reductions as consumers, who wish to reduce energy consumption for monetary, environmental, and other reasons, face barriers. One such barrier is a lack of knowledge or understanding of how energy is consumed in a home and how to reduce this consumption effectively through behavioral and technological changes. One way to improve understanding of residential energy consumption is through the creation of a model to predict which appliances and electronics will be present and significantly contribute to the electricity consumption of a home on the basis of various characteristics of that home. The basis of this model is publically available survey data from the Residential Energy Consumption Survey (RECS). By predicting how households are likely to consume energy, homeowners, policy makers, and other stakeholders have access to valuable data that enables reductions in energy consumption in the residential sector. This model can be used to select homes that may be ripe for energy reductions and to predict the appliances that are the basis of these potential reductions. This work suggests that most homes in the U.S. have about eight appliances that are responsible for about 80% of the electricity consumption in that home. Characteristics such as census region, floor space, income, and total electricity consumption affect which appliances are likely to be in a home, however the number of appliances is generally around 8. Generally it takes around 4 appliances to reach the 50% threshold and 12 appliances to reach 90% of electricity

  2. Measuring Tax Efficiency

    DEFF Research Database (Denmark)

    Raimondos-Møller, Pascalis; Woodland, Alan D.

    2004-01-01

    This paper introduces an index of tax optimality thatmeasures the distance of some current tax structure from the optimal taxstructure in the presence of public goods. In doing so, we derive a [0, 1]number that reveals immediately how far the current tax configurationis from the optimal one and......, thereby, the degree of efficiency of a taxsystem. We call this number the Tax Optimality Index. We show howthe basic method can be altered in order to derive a revenue equivalentuniform tax, which measures the size of the public sector. A numericalexample is used to illustrate the method developed.......JEL Code: H21, H41.Keywords: Tax optimality index, excess burden, distance function.Authors Affiliations: Raimondos-Møller: Copenhagen Business School, CEPR,CESifo, and EPRU. Woodland: University of Sydney....

  3. Residential carbon dioxide emissions in Canada. Impact of efficiency improvements and fuel substitution

    International Nuclear Information System (INIS)

    Ugursal, V.I.; FUng, A.S.

    1998-01-01

    The effect of improving house envelope, heating system and appliance efficiencies, and fuel substitution on the atmospheric emissions of carbon dioxide in the Canadian residential sector is studied based on simulation studies. The findings clearly indicate that improving appliance efficiency reduces the overall end-use energy consumption in the residential sector as well as the associated carbon dioxide emissions. However, the magnitude of the reduction in carbon dioxide emissions as a result of improving only appliance efficiencies is quite small. Significantly larger reductions can be obtained by improving house envelopes and heating/cooling systems in addition to improving appliance efficiencies. Fuel substitution for space and domestic hot water heating can also present a potential to reduce carbon dioxide emissions depending on the fuel substitution scenario adopted. (author)

  4. Residential energy efficiency retrofits: How program design affects participation and outcomes

    International Nuclear Information System (INIS)

    Hoicka, Christina E.; Parker, Paul; Andrey, Jean

    2014-01-01

    Better methods of characterizing and addressing heterogeneity in preferences and decision making are needed to stimulate reductions in household greenhouse gas emissions. Four residential energy efficiency programs were delivered consecutively in the Region of Waterloo, Canada, between 1999 and 2011, and each offered a unique combination of information, financial reward structure, and price. A natural quasi-experimental intervention design was employed to assess differences in outcomes across these program structures. Participation at the initial (evaluation by an energy advisor) and follow-up (verification of retrofit) stages, and the material characteristics (e.g., energy performance) were measured and compared between the groups of houses included in each program at each stage. The programs appealed to people with different types of material concerns; each phase of the program was associated with houses with a different mix of material characteristics and depths of recommended and achieved changes. While a performance-based reward attracted fewer houses at each stage than a larger list-based reward, older houses with poorer energy performance were included at each stage. The findings support experimentation with program designs to target sub-populations of housing stock; future program designs should experiment more carefully and with larger performance-based rewards and test parallels with potential carbon market structures. - Highlights: • Multi-program data over 12 years detailing residential energy retrofits. • Natural experimental intervention research design for program evaluation. • Number and attributes of participating households differed by program design. • Financial rewards attracted more participants to the verification stage. • Performance-based incentives have the largest potential for energy savings

  5. Development of a new energy efficiency rating system for existing residential buildings

    International Nuclear Information System (INIS)

    Koo, Choongwan; Hong, Taehoon; Lee, Minhyun; Seon Park, Hyo

    2014-01-01

    Building energy efficiency rating systems have been established worldwide to systematically manage the energy consumption of existing buildings. This study aimed to develop a new energy efficiency rating system for existing residential buildings from two perspectives: (i) establishment of reasonable and fair criteria for the building energy efficiency rating system; and (ii) establishment of comparative incentive and penalty programs to encourage the voluntary participation of all residents in the energy saving campaign. Based on the analysis of the conventional energy efficiency rating system for existing residential buildings, this study was conducted in five steps: (i) data collection and analysis; (ii) correlation analysis between the household size and the CO 2 emission density (i.e., CO 2 emission per unit area); (iii) cluster formation based on results of the correlation analysis using a decision tree; (iv) establishment of a new energy efficiency rating system for existing buildings; and (v) establishment of incentive and penalty programs using advanced case-based reasoning. The proposed system can allow a policymaker to establish a reasonable and fair energy efficiency rating system for existing residential buildings and can encourage the voluntary participation of all residents in the energy saving campaign. - Highlights: • A new energy efficiency rating system for the residential building was developed. • The incentive and penalty programs were established using an advanced CBR model. • The new system was established using reasonable and fair standards. • It allows all residents to voluntarily participate in the energy saving campaign. • It can be applied to any country or sector in the global environment

  6. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  7. Capture Efficiency of Cooking-Related Fine and Ultrafine Particles by Residential Exhaust Hoods

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa M.; Delp, William W.

    2014-06-05

    Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80percent. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38percent for low (51?68 L s-1) and 54?72percent for high (109?138 L s-1) settings. CEs for 0.3?2.0 ?m particles during front burner stir-frying were 3?11percent on low and 16?70percent on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80percent both for burner combustion products and for cooking-related particles.

  8. Capture efficiency of cooking-related fine and ultrafine particles by residential exhaust hoods.

    Science.gov (United States)

    Lunden, M M; Delp, W W; Singer, B C

    2015-02-01

    Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking-generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80%. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38% for low (51-68 l/s) and 54-72% for high (109-138 l/s) settings. CEs for 0.3-2.0 μm particles during front burner stir-frying were 3-11% on low and 16-70% on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80% both for burner combustion products and for cooking-related particles. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  9. Is Efficiency Enough? Towards a New Framework for Carbon Savingsin the California Residential Sector

    Energy Technology Data Exchange (ETDEWEB)

    Moezzi, Mithra; Diamond, Rick

    2005-10-01

    The overall implementation of energy efficiency in the United States is not adequately aligned with the environmental benefits claimed for efficiency, because it does not consider absolute levels of energy use, pollutant emissions, or consumption. In some ways, promoting energy efficiency may even encourage consumption. A more effective basis for environmental policy could be achieved by recognizing the degree and nature of the synchronization between environmental objectives and efficiency. This research seeks to motivate and initiate exploration of alternative ways of defining efficiency or otherwise moderating energy use toward reaching environmental objectives, as applicable to residential electricity use in California. The report offers three main recommendations: (1) produce definitions of efficiency that better integrate absolute consumption, (2) attend to the deeper social messages of energy efficiency communications, and (3) develop a more critical perspective on benefits and limitations of energy efficiency for delivering environmental benefits. In keeping with the exploratory nature of this project, the report also identifies ten questions for further investigation.

  10. Field performance of energy-efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    The airtightness of 24 new houses was measured on a regular basis over periods of up to three years to evaluate the structures' air barrier systems and to study the possibility of air barrier degradation, as would be indicated by an increase in the measured air leakage rate. Ten of the houses were built with the polyethylene air barrier system and 14 using an early version of the airtight drywall approach (ADA). The 24 project houses were architecturally similar and of approximately equal size and general layout; stucco was the predominate wall finish.

  11. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

    2011-06-01

    Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The

  12. Fire Situations and Prevention Measures of residential building

    Directory of Open Access Journals (Sweden)

    Zhou Baixia

    2017-01-01

    Full Text Available The proportion of residential building is the largest in all buildings. With the development of urbanization, residential building fires are at high momentum. The paper lists the residential building fires and the number of casualties’ proportion to total fires from 2011 to 2014, analyzing the high incidence causes of the fires and casualties and putting forward suggestions and countermeasures including carrying out fire safety education to improve the fire safety awareness of residents, fulfilling responsibility to enhancing fire safety management capabilities, perfecting fire apparatus to develop fire safety environment and enhancing public awareness of fire safety, equipping evacuation equipments to promote response ability to deal with disasters etc.

  13. Measuring Group Care Worker Interventions in Residential Youth Care

    NARCIS (Netherlands)

    Bastiaanssen, I.L.W.; Kroes, G.; Nijhof, K.S.; Delsing, M.J.M.H.; Engels, R.C.M.E.; Veerman, J.W.

    2012-01-01

    Background By interacting with children, group care workers shape daily living environments to influence treatment. Current literature provides little knowledge about the content of youth residential care. Objective In this study, a questionnaire called the Group care worker Intervention

  14. Solar cell efficiency measurements

    International Nuclear Information System (INIS)

    Ostoja, P.

    1989-01-01

    Solar cells (and solar modules) have to be tested for their performance by means of sound reliable measurement procedures. The need for such measurements arises at various stages of research, of production, and of photovoltaic systems sizing and dimensioning. In fact, accurate measurements are necessary to the researcher, who studies new materials and new processes, to the manufacturer, who has to control his product and, finally, to the user, who needs sound measurements, in order to be in a position to make effective decisions about what kink of product will be needed and with what critical characteristics. In short, standard measurements that allow cells and modules to be characterized serve as a common language, allowing effective communication about products and requirements. 3 refs

  15. Smart density: A more accurate method of measuring rural residential density for health-related research.

    Science.gov (United States)

    Owens, Peter M; Titus-Ernstoff, Linda; Gibson, Lucinda; Beach, Michael L; Beauregard, Sandy; Dalton, Madeline A

    2010-02-12

    Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. We compared residential density (units/acre) in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block) with two GIS buffer measures: a 1-kilometer (km) circle around the school and a 1-km circle intersected with a 100-meter (m) road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  16. Smart density: a more accurate method of measuring rural residential density for health-related research

    Directory of Open Access Journals (Sweden)

    Gibson Lucinda

    2010-02-01

    Full Text Available Abstract Background Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. Objective We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. Methods We compared residential density (units/acre in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block with two GIS buffer measures: a 1-kilometer (km circle around the school and a 1-km circle intersected with a 100-meter (m road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Results Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Conclusion Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  17. Valuing Residential Energy Efficiency in Two Alaska Real Estate Markets: A Hedonic Approach

    Science.gov (United States)

    Pride, Dominique J.

    Alaska households have high home energy consumption and expenditures. Improving the energy efficiency of the housing stock can reduce home energy consumption, thereby reducing home energy expenditures and CO2 emissions. Improving the energy efficiency of a home may also increase its transaction price if the energy efficiency improvements are capitalized into the value of the home. The relationship between energy efficiency and transaction prices in the Fairbanks and Anchorage, Alaska residential real estate markets is examined. Using a hedonic pricing framework and difference-in-differences analysis, the impact of the Alaska Home Energy Rebate program on the transaction prices of single-family homes in the Fairbanks and Anchorage housing markets from 2008 through 2015 is examined. The results indicate that compared to homes that did not complete the program, homes that completed the program sell for a statistically significant price premium between 15.1% and 15.5% in the Fairbanks market and between 5% and 11% in the Anchorage market. A hedonic pricing framework is used to relate energy efficiency ratings and transaction prices of homes in the Fairbanks and Anchorage residential real estate markets from 2008 through 2015. The results indicate that homes with above-average energy efficiency ratings sell for a statistically significant price premium between 6.9% and 17.5% in the Fairbanks market and between 1.8% and 6.0% in the Anchorage market.

  18. Refining the COPES to Measure Social Climate in Therapeutic Residential Youth Care

    Science.gov (United States)

    Leipoldt, Jonathan D.; Kayed, Nanna S.; Harder, Annemiek T.; Grietens, Hans; Rimehaug, Tormod

    2018-01-01

    Background: Previous studies have shown that social climate in therapeutic residential youth care (TRC) is important to the welfare of residents, staff, and assessing treatment outcomes. The most influential theory on social climate in residential settings is the theory of Moos. The measurement of the concepts and aspects of this theory using the…

  19. Residential Energy Efficiency Research Planning Meeting Summary Report: Washington, D.C. - October 27-28, 2011

    Energy Technology Data Exchange (ETDEWEB)

    2012-02-01

    This report summarizes key findings and outcomes from the U.S. Department of Energy's Building America Residential Energy Efficiency Research Planning meeting, held on October 28-29, 2011, in Washington, D.C.

  20. Essays in economics of energy efficiency in residential buildings - An empirical analysis[Dissertation 17157

    Energy Technology Data Exchange (ETDEWEB)

    Jakob, M.

    2007-07-01

    Energy efficiency in the building sector is a key element of cost-effective climate change and energy policies in most countries throughout the world. (...) However, a gap between the cost-effectiveness of energy efficiency measures, their benefits, the necessities from a societal point of view on the one hand and the actual investments in the building stock - particularly in the moment of re-investment and refurbishing - on the other hand became more and more evident. The research questions that arose against this background were whether this gap and the low energy efficiency levels and rates could be confirmed empirically and if yes, how the gap could be explained and how it could be overcome by adequate policy measures. To address these questions, the multi-functional character of buildings (i.e. well conditioned and quiet living rooms and working space) had to be considered. Associated benefits arise on the societal level (ancillary benefits) and on the private level (co-benefits), the latter being increasingly addressed by different building labels such as 'Minergie', 'Passive House', and others. It was assumed that these co-benefits are of economic relevance, but empirical evidence regarding their economic value was missing. Thus, putting these benefits into an appropriate economic appraisal framework was at stake to make use of them in market information and policy instruments, preventing uninformed and biased cost benefit analyses and decisions on the private and on the societal level. The research presented in this PhD thesis had the goal to provide a sound empirical basis about costs and benefits of energy efficiency investments in residential buildings, with a special emphasis on the economic valuation of their co-benefits from a building user perspective (owner-occupiers, purchasers and tenants). In view of long time-horizons in the building sector, the techno-economic dynamics should also be addressed. The results should be useful

  1. From energy efficiency to integrated sustainable urbanism in residential development in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhichang Cai

    2010-06-15

    China has adopted Sustainable Development as a national strategy for all industries. In civil construction sector, sustainability is regarded as the development of Green Building in China. Since 2000, China has introduced a series of policies and laws to promote Green Building. Green Building was defined as buildings that are 'energy-efficient, land-efficient, water-efficient, and material-efficient' and emit 'minimal pollution' in during its entire life cycle, and meets a specified standard for indoor environment at the same time. However, energy efficiency is the central issue of current Green Building development in China, while issues of resources and pollution are neglected, which is partly due to China's energy structure. Social and economic aspects are also always ignored. The main aim of this thesis is to map pathways towards more comprehensive frameworks for how residential areas in China could be constructed in a more sustainable way in hot summer and cold-winter area. Case study was the main method used to examine the specifications of Green Residential Building in China. This paper offers a general overview of the current green trend in China and presents a specific analysis on three cases to search for the proper approach for China's unique situation by three specific cases representing three types of Green Building: Modern Vernacular Architecture, Eco-office and Mass-housing, according to their features in scale, location and function. This paper then presents a specific integrated sustainability analysis of the Landsea Housing Project in Nanjing, a hot-summer/cold-winter zone. Hammarby Sjoestad, a cutting edge project in Stockholm, is also discussed as a reference area from which experiences can be drawn for China. The aim was to improve the framework for construction of residential buildings in China in a more sustainable way, from energy efficiency to integrated sustainability. The paper also discusses the relationship

  2. Energy efficiency policies and measures

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This document makes a review of the energy efficiency and demand side management (DSM) policies and measures in European Union countries and Norway in 1999: institutional changes, measures and programmes, budget, taxation, existence of a national DSM programme, national budgets for DSM programmes, electricity pricing: energy/environment tax, national efficiency standards and regulation for new electrical appliances, implementation of Commission directives, efficiency requirements, labelling, fiscal and economic incentives. (J.S.)

  3. A method of identifying and weighting indicators of energy efficiency assessment in Chinese residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yulan [Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment under Ministry of Education, Chongqing University, Chongqing (China); College of Civil Engineering and Architecture, Zhejiang University of Technology, Hangzhou (China); Li Baizhan [Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment under the Ministry of Education, Chongqing University, Chongqing (China); Yao Runming, E-mail: r.yao@reading.ac.u [School of Construction Management and Engineering, University of Reading, Reading (United Kingdom); Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment under Ministry of Education, Chongqing University, Chongqing (China)

    2010-12-15

    This paper describes a method of identifying and weighting indicators for assessing the energy efficiency of residential buildings in China. A list of indicators of energy efficiency assessment in residential buildings in the hot summer and cold winter zone in China has been proposed, which supplies an important reference for policy makings in energy efficiency assessment in buildings. The research method applies a wide-ranging literature review and a questionnaire survey involving experts in the field. The group analytic hierarchy process (group AHP) has been used to weight the identified indicators. The size of survey samples are sufficient to support the results, which has been validated by consistency estimation. The proposed method could also be extended to develop the weighted indicators for other climate zones in China. - Research highlights: {yields}Method of identifying indicators of building energy efficiency assessment. {yields}The group AHP method for weighting indicators. {yields}Method of solving multi-criteria decision making problems of choice and prioritisation in policy makings.

  4. Estimating the energy and exergy utilization efficiencies for the residential-commercial sector: an application

    International Nuclear Information System (INIS)

    Utlu, Zafer; Hepbasli, Arif

    2006-01-01

    The main objectives in carrying out the present study are twofold, namely to estimate the energy and exergy utilization efficiencies for the residential-commercial sector and to compare those of various countries with each other. In this regard, Turkey is given as an illustrative example with its latest figures in 2002 since the data related to the following years are still being processed. Total energy and exergy inputs in this year are calculated to be 3257.20 and 3212.42 PJ, respectively. Annual fuel consumptions in space heating, water heating and cooking activities as well as electrical energy uses by appliances are also determined. The energy and exergy utilization efficiency values for the Turkish residential-commercial sector are obtained to be 55.58% and 9.33%, respectively. Besides this, Turkey's overall energy and exergy utilization efficiencies are found to be 46.02% and 24.99%, respectively. The present study clearly indicates the necessity of the planned studies toward increasing exergy utilization efficiencies in the sector studied

  5. A method of identifying and weighting indicators of energy efficiency assessment in Chinese residential buildings

    International Nuclear Information System (INIS)

    Yang Yulan; Li Baizhan; Yao Runming

    2010-01-01

    This paper describes a method of identifying and weighting indicators for assessing the energy efficiency of residential buildings in China. A list of indicators of energy efficiency assessment in residential buildings in the hot summer and cold winter zone in China has been proposed, which supplies an important reference for policy makings in energy efficiency assessment in buildings. The research method applies a wide-ranging literature review and a questionnaire survey involving experts in the field. The group analytic hierarchy process (group AHP) has been used to weight the identified indicators. The size of survey samples are sufficient to support the results, which has been validated by consistency estimation. The proposed method could also be extended to develop the weighted indicators for other climate zones in China. - Research highlights: →Method of identifying indicators of building energy efficiency assessment. →The group AHP method for weighting indicators. →Method of solving multi-criteria decision making problems of choice and prioritisation in policy makings.

  6. Measuring preferences for parking facilities in old residential areas

    NARCIS (Netherlands)

    Borgers, A.W.J.; Kemperman, A.D.A.M.; Toll, L.M.M.; Timmermans, H.J.P.

    2010-01-01

    One of the problems in restructuring old residential areas in European cities is parking. The narrow streets and lack of open spaces challenge city planners to find solutions to this problem. Insight in preferences regarding possible parking solutions may facilitate the development of restructure

  7. Incentive mechanism design for the residential building energy efficiency improvement of heating zones in North China

    International Nuclear Information System (INIS)

    Zhong, Y.; Cai, W.G.; Wu, Y.; Ren, H.

    2009-01-01

    Starting with analyzing the investigation results by Ministry of Housing and Urban-Rural Development of China in 2005, more than half of the 10,236 participants are willing to improve the residential building energy efficiency and accept an additional cost of less than 10% of the total cost, the authors illustrate that incenting actions are necessary to improve building energy efficiency and build a central government-local government-market model. As a result of the model analysis, to pursue good execution effects brought by the incentive policies, the executors are required to distinguish the differences of incentive objects' economic activities and strongly respect the incenting on the energy conservation performance. A case study on the incentive policies of existing residential building energy efficiency improvement in heating zones in North China is given as well. Finally, it is strongly recommended to give the first priority to performance-based incentives so that to reduce the lazy behaviors of the incented objects and ensure the targets to be achieved.

  8. Pattern analysis and suggestion of energy efficiency retrofit for existing residential buildings in China's northern heating region

    International Nuclear Information System (INIS)

    Lv Shilei; Wu Yong; Sun Jinying

    2009-01-01

    In China, Energy Efficiency Retrofit for Existing Residential Buildings (EERFERB) is faced with a fast development status. The Central Government decided to prompt the retrofit of 1.5x10 8 m 2 existing residential buildings in China's northern heating region during the '11th Five-Years Plan'. But, at present, the relative incentive policies and measurements are very insufficient. Especially, on the aspect of the retrofit pattern about the organization, retrofit content, investing and financing mode, the policy and management and other factors, no existing successful one can be spreaded into the whole northern heating region. This research not only analyzed the foreign advanced methods, drew lessons from their retrofit in Germany and Poland, but contrasted and analyzed energy efficiency retrofit demonstrations from Harbin, Tianjin, Tangshan and Baotou in China to get our domestic successful patterns and experience. Finally, some recommended retrofit patterns are presented, which can be applied for the instruction and decision-making for the Chinese local governments.

  9. The Boom of Electricity Demand in the Residential Sector in the Developing World and the Potential for Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie; McNeil, Michael A.

    2008-05-13

    With the emergence of China as the world's largest energy consumer, the awareness of developing country energy consumption has risen. According to common economic scenarios, the rest of the developing world will probably see an economic expansion as well. With this growth will surely come continued rapid growth in energy demand. This paper explores the dynamics of that demand growth for electricity in the residential sector and the realistic potential for coping with it through efficiency. In 2000, only 66% of developing world households had access to electricity. Appliance ownership rates remain low, but with better access to electricity and a higher income one can expect that households will see their electricity consumption rise significantly. This paper forecasts developing country appliance growth using econometric modeling. Products considered explicitly - refrigerators, air conditioners, lighting, washing machines, fans, televisions, stand-by power, water heating and space heating - represent the bulk of household electricity consumption in developing countries. The resulting diffusion model determines the trend and dynamics of demand growth at a level of detail not accessible by models of a more aggregate nature. In addition, the paper presents scenarios for reducing residential consumption through cost-effective and/or best practice efficiency measures defined at the product level. The research takes advantage of an analytical framework developed by LBNL (BUENAS) which integrates end use technology parameters into demand forecasting and stock accounting to produce detailed efficiency scenarios, which allows for a realistic assessment of efficiency opportunities at the national or regional level. The past decades have seen some of the developing world moving towards a standard of living previously reserved for industrialized countries. Rapid economic development, combined with large populations has led to first China and now India to emerging as &apos

  10. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  11. Field Testing of Energy-Efficient Flood-Damage-Resistant Residential Envelope Systems Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Aglan, H.

    2005-08-04

    The primary purpose of the project was to identify materials and methods that will make the envelope of a house flood damage resistant. Flood damage resistant materials and systems are intended to be used to repair houses subsequent to flooding. This project was also intended to develop methods of restoring the envelopes of houses that have been flooded but are repairable and may be subject to future flooding. Then if the house floods again, damage will not be as extensive as in previous flood events and restoration costs and efforts will be minimized. The purpose of the first pair of field tests was to establish a baseline for typical current residential construction practice. The first test modules used materials and systems that were commonly found in residential envelopes throughout the U.S. The purpose of the second pair of field tests was to begin evaluating potential residential envelope materials and systems that were projected to be more flood-damage resistant and restorable than the conventional materials and systems tested in the first pair of tests. The purpose of testing the third slab-on-grade module was to attempt to dry flood proof the module (no floodwater within the structure). If the module could be sealed well enough to prevent water from entering, then this would be an effective method of making the interior materials and systems flood damage resistant. The third crawl space module was tested in the same manner as the previous modules and provided an opportunity to do flood tests of additional residential materials and systems. Another purpose of the project was to develop the methodology to collect representative, measured, reproducible (i.e. scientific) data on how various residential materials and systems respond to flooding conditions so that future recommendations for repairing flood damaged houses could be based on scientific data. An additional benefit of collecting this data is that it will be used in the development of a standard test

  12. Evaluating Cool Impervious Surfaces: Application to an Energy-Efficient Residential Roof and to City Pavements

    Science.gov (United States)

    Rosado, Pablo Javier

    Summer urban heat island (UHI) refers to the phenomenon of having higher urban temperatures compared to the those in surrounding suburban and rural areas. Higher urban air temperatures lead to increased cooling demand, accelerates the formation of smog, and contributes to the generation of greenhouse gas emissions. Dark-colored impervious surfaces cover a significant fraction of an urban fabric, and as hot and dry surfaces, are a major contributor to the UHI effect. Adopting solar-reflective ("cool") roofs and cool pavements, and increasing the urban vegetation, are strategies proven to mitigate urban heat islands. These strategies often have an "indirect" effect (ambient cooling) and "direct" effect (change in solar energy flux entering the conditioned space) on the energy use of buildings. This work investigates some elements of the UHI mitigation strategies, specifically the annual direct effect of a cool roof, and the direct and indirect effects of cool pavements. The first topic researched in this paper consists in an experimental assessment of the direct effects from replacing a conventional dark roof with a highly energy-efficient cool roof. The study measures and calculates the annual benefits of the cool roof on the cooling and heating energy uses, and the associated emission reductions. The energy savings attributed to the cool roof are validated by measuring the difference between the homes in the heat loads that entered the conditioned space through the ceiling and HVAC ducts. Fractional annual cooling energy savings (26%) were 2.6 times the 10% daily cooling energy savings measured in a previous study that used a white coating to increase the albedo of an asphalt shingle roof by the same amount (0.44). The improved cooling energy savings (26% vs. 10%) may be attributed to the cool tile's above-sheathing ventilation, rather than to its high thermal mass. The roof also provided energy savings during the heating season, yielding fractional annual gas

  13. The effectiveness of energy efficiency improvement in a developing country: Rebound effect of residential electricity use in South Korea

    International Nuclear Information System (INIS)

    Jin, Sang-Hyeon

    2007-01-01

    The government of South Korea considers an energy efficiency improvement policy an effective economic measure for climate change like many other governments. But it is unaware of any 'rebound effect', the unexpected result of energy efficiency improvement. So the rebound effect of residential electricity use in South Korea was estimated using two different scales in this paper. At the macro level, the rebound effect was estimated indirectly by using price elasticity, and at the micro level, the rebound effect of individual home appliances was estimated directly by using a non-linear relationship between energy efficiency and energy use. At the macro level, the long- and short-term results of rebound effect were estimated at 30% and 38%, respectively. Also at the micro level, the rebound effect of air conditioners was 57-70%; while refrigerators showed only a composite of rebound and income effects. Finally, there was no backfire effect, and efficiency improvement brought energy reduction. In conclusion, these suggest that rebound effect is an important factor that the government of South Korea must consider when planning its energy efficiency improvement policy. (author)

  14. Efficiency Analyses of a DC Residential Power Distribution System for the Modern Home

    Directory of Open Access Journals (Sweden)

    GELANI, H. E.

    2015-02-01

    Full Text Available The electric power system started as DC back in the nineteenth century. However, the DC paradigm was soon ousted by AC due to inability of DC to change its voltage level. Now, after many years, with the development of power electronic converters capable of stepping-up and down DC voltage and converting it to-and-from AC, DC appears to be challenging AC and attempting a comeback. We now have DC power generation by solar cells, fuel cells and wind farms, DC power transmission in the form of HVDC (High Voltage DC transmission, DC power utilization by various modern electronic loads and DC power distribution that maybe regarded as still in research phase. This paper is an attempt to investigate feasibility of DC in the distribution portion of electrical power system. Specifically, the efficiency of a DC distribution system for residential localities is determined while keeping in view the concept of daily load variation. The aim is to bring out a more practical value of system efficiency as the efficiencies of DC/DC converters making up the system vary with load variation. This paper presents the modeling and simulation of a DC distribution system and efficiency results for various scenarios are presented.

  15. Promoting high efficiency residential HVAC equipment: Lessons learned from leading utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Neme, C.; Peters, J.; Rouleau, D.

    1998-07-01

    The Consortium for Energy Efficiency recently sponsored a study of leading electric utility efforts to promote high efficiency residential HVAC equipment. Given growing concerns from some utilities about the level of expenditures associated with rebate programs, special emphasis was placed on assessing the success of financing and other non-rebate options for promoting efficiency. Emphasis was also placed on review of efforts--rebate or otherwise--to push the market to very high levels of efficiency (i.e., SEER 13). This paper presents the results of the study. It includes discussion of key lessons from the utility programs analyzed. It also examines program participation rates and other potential indicators of market impacts. One notable conclusion is that several utility programs have pushed market shares for SEER 12 equipment to about 50% (the national average is less than 20%). At least one utility program has achieved a 50% market share for SEER 13 equipment (the national average is less than 3%). In general, financing does not appear to have as broad an appeal as consumer rebates. However, one unique utility program which combines the other of customer financing with modest incentives to contractors--in the form of frequent seller points that can be redeemed for advertising, technician training, travel and other merchandise--offers some promise that high participation rates can be achieved without customer rebates.

  16. Efficiency measures for industrial organization

    NARCIS (Netherlands)

    ten Raa, Thijs; Ray, Subhash C.; Kumbhakar, Subal C.; Dua, Pami

    2015-01-01

    The aim of the paper is to measure the efficiency of an industry, and to decompose it in firm efficiencies—which indicate how close firms approximate best practices—and an organization efficiency—which indicates the degree of optimality of the number of firms and their distribution. The latter

  17. LABORATORY EVALUATION OF AIR FLOW MEASUREMENT METHODS FOR RESIDENTIAL HVAC RETURNS

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-02-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  18. Assessing National Employment Impacts of Investment in Residential and Commercial Sector Energy Efficiency: Review and Example Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, David M.; Belzer, David B.; Livingston, Olga V.; Scott, Michael J.

    2014-06-18

    Pacific Northwest National Laboratory (PNNL) modeled the employment impacts of a major national initiative to accelerate energy efficiency trends at one of two levels: • 15 percent savings by 2030. In this scenario, efficiency activities save about 15 percent of the Annual Energy Outlook (AEO) Reference Case electricity consumption by 2030. It is assumed that additional energy savings in both the residential and commercial sectors begin in 2015 at zero, and then increase in an S-shaped market penetration curve, with the level of savings equal to about 7.0 percent of the AEO 2014 U.S. national residential and commercial electricity consumption saved by 2020, 14.8 percent by 2025, and 15 percent by 2030. • 10 percent savings by 2030. In this scenario, additional savings begin at zero in 2015, increase to 3.8 percent in 2020, 9.8 percent by 2025, and 10 percent of the AEO reference case value by 2030. The analysis of the 15 percent case indicates that by 2030 more than 300,000 new jobs would likely result from such policies, including an annual average of more than 60,000 jobs directly supporting the installation and maintenance of energy efficiency measures and practices. These are new jobs resulting initially from the investment associated with the construction of more energy-efficient new buildings or the retrofit of existing buildings and would be sustained for as long as the investment continues. Based on what is known about the current level of building-sector energy efficiency jobs, this would represent an increase of more than 10 percent from the current estimated level of over 450,000 such jobs. The more significant and longer-lasting effect comes from the redirection of energy bill savings toward the purchase of other goods and services in the general economy, with its attendant influence on increasing the total number of jobs. This example analysis utilized PNNL’s ImSET model, a modeling framework that PNNL has used over the past two decades to assess

  19. Green signalling effects in the market for energy-efficient residential buildings

    International Nuclear Information System (INIS)

    Fuerst, Franz; Oikarinen, Elias; Harjunen, Oskari

    2016-01-01

    Highlights: • Energy efficiency (EE) levels are hypothesised to affect house transaction prices. • We estimate a hedonic model using Energy Performance Certificates from Finland. • A price premium is found for the most energy-efficient properties. • The empirical results are suggestive of a green signalling effect. • Demand for EE high performers appears to be segmented from lower tiers. - Abstract: Empirical evidence from recent studies suggests that the price premium on energy-efficient buildings is potentially higher than the pure capitalisation of energy savings but the empirical evidence on the size of the non-savings components is scant. This study aims to fill this research gap by investigating whether the mandatory energy efficiency ratings for residential properties imply benefits that go beyond energy savings. Using a sample of several thousand apartment transactions from Helsinki, Finland, we first test if higher ratings were significantly associated with higher prices. In addition to a large number of property and neighbourhood characteristics, this dataset contains information on building-level energy usage which allows us to distinguish between the cost savings effect of energy consumption and the value of more intangible factors associated with the energy label. The hedonic model yields a statistically significant 3.3% price premium for apartments in the top three energy-efficiency categories and 1.5% when a set of detailed neighbourhood characteristics are included. When maintenance costs containing energy usage costs are added, a robust and significant price premium of 1.3% persists whereas no differentiation is found for the medium and lower rating categories. These findings may be indicative of energy-efficient buildings having signalling value – and therefore an additional incentive to invest in such buildings – for ‘green’ consumers. However, a favourable energy rating did not appear to speed up the sales process in the

  20. INTERNATIONAL COMPARISON OF RESIDENTIAL ENERGY USE: INDICATORS OF RESIDENTIAL ENERGY USE AND EFFICIENCY PART ONE: THE DATA BASE

    Energy Technology Data Exchange (ETDEWEB)

    Schipper, L.; Ketoff, A.; Meyers, S.

    1981-05-01

    This summary report presents information on the end-uses of energy in the residential sector of seven major OECD countries over the period 1960-1978. Much of the information contained herein has never been published before. We present data on energy consumption by energy type and end-use for three to five different years for each country. Each year table is complemented by a set of indicators, which are assembled for the entire 20-year period at the end of each country listing. Finally, a set of key indicators from each country is displayed together in a table, allowing comparison for three periods: early (1960-63), pre-embargo (1970-73), and recent (1975-78). Analysis of these results, smoothing and interpolation of the data, addition of further data, and analytical comparison of in-country and cross-country trends will follow in the next phase of our work.

  1. Efficient measurement of radon daughters

    International Nuclear Information System (INIS)

    Rolle, R.

    1992-01-01

    In environmental control there is an increasing need for efficient measurement of radon and thoron daughters in air. Measuring instruments should be rugged and portable for field use, while also permitting unattended operation for several days. Simple operating procedures should permit evaluation of rapidly changing concentrations over extended periods. These requirements demand careful balance in the design of hardware and measuring procedures. The design principles for a continuous flow-through spectrometer, that has been developed for precision sequential measurement of radon and thoron daughters, are described. Because of the high precision of measurement, this type of instrument should find application in environments from technologically enhanced natural radiation to the very lowest natural background situations. (author)

  2. Summary of Needs and Opportunities from the 2011 Residential Energy Efficiency Meeting: Atlanta, Georgia, March 16-18, 2011

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-05-01

    This meeting brought together more than 200 professionals representing organizations with vested interest in energy efficiency improvements in residential buildings. Participants identified or reinforced a wide variety of needs and issues associated with delivering high-performance homes in both new and existing home scenarios,

  3. The evaluation of retrofit measures in a tall residential building

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, M.M.; McLain, H.A.

    1995-07-01

    As part of a joint demonstration effort involving the US Department of Energy (DOE), the US Department of Housing and Urban Development (HUD), Boston Edison Company (BECo), and the Chelsea Housing Authority, Oak Ridge National Laboratory (ORNL) participated in the evaluation of energy and demand saving retrofits for a tall residential building located in Boston. The thirteen story all-electric building underwent window, lighting, and control renovations in December, 1992. annual energy consumption was reduced by 15% and peak demand fell by 17%. Hourly should building consumption data were available for the comparison of pre- and post- conditions and for calibration of a DOE-2.1D simulation model. The analysis found the window retrofit accounted for 90% of total energy savings and 95% of average demand savings, due to reductions in both conduction and infiltration. Benefits from lighting retrofits were low in cooling months and negligible in winter months due to the increase in the demand for electric resistance heating which was proportional to the reduction in lighting capacity. Finally, the simulation model verified that heating system controls had not been used as intended, and that the utility rate structure would not allow cost savings from the original control strategy. These results and other interesting lessons learned are presented.

  4. Efficiency Analysis of Independent and Centralized Heating Systems for Residential Buildings in Northern Italy

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2011-11-01

    Full Text Available The primary energy consumption in residential buildings is determined by the envelope thermal characteristics, air change, outside climatic data, users’ behaviour and the adopted heating system and its control. The new Italian regulations strongly suggest the installation of centralized boilers in renovated buildings with more than four apartments. This work aims to investigate the differences in primary energy consumption and efficiency among several independent and centralized heating systems installed in Northern Italy. The analysis is carried out through the following approach: firstly building heating loads are evaluated using the software TRNSYS® and, then, heating system performances are estimated through a simplified model based on the European Standard EN 15316. Several heating systems have been analyzed, evaluating: independent and centralized configurations, condensing and traditional boilers, radiator and radiant floor emitters and solar plant integration. The heating systems are applied to four buildings dating back to 2010, 2006, 1960s and 1930s. All the combinations of heating systems and buildings are analyzed in detail, evaluating efficiency and primary energy consumption. In most of the cases the choice between centralized and independent heating systems has minor effects on primary energy consumption, less than 3%: the introduction of condensing technology and the integration with solar heating plant can reduce energy consumption by 11% and 29%, respectively.

  5. Energy efficiency campaign for residential housing at the Fort Lewis army installation

    Energy Technology Data Exchange (ETDEWEB)

    AH McMakin; RE Lundgren; EL Malone

    2000-02-23

    In FY1999, Pacific Northwest National Laboratory conducted an energy efficiency campaign for residential housing at the Fort Lewis Army Installation near Tacoma, Washington. Preliminary weather-corrected calculations show energy savings of 10{percent} from FY98 for energy use in family housing. This exceeded the project's goal of 3{percent}. The work was funded by the U.S. DOEs Federal Energy Management Program (FEMP), Office of Energy Efficiency and Renewable Energy. The project adapted FEMP's national ``You Have the Power Campaign'' at the local level, tailoring it to the military culture. The applied research project was designed to demonstrate the feasibility of tailored, research-based strategies to promote energy conservation in military family housing. In contrast to many energy efficiency efforts, the campaign focused entirely on actions residents could take in their own homes, as opposed to technology or housing upgrades. Behavioral change was targeted because residents do not pay their own utility bills; thus other motivations must drive personal energy conservation. This campaign augments ongoing energy savings from housing upgrades carried out by Fort Lewis. The campaign ran from September 1998 through August 1999. The campaign strategy was developed based on findings from previous research and on input from residents and officials at Fort Lewis. Energy use, corrected to account for weather differences, was compared with the previous year's use. Survey responses from 377 of Fort Lewis residents of occupied housing showed that the campaign was moderately effective in promoting behavior change. Of those who were aware of the campaign, almost all said they were now doing one or more energy-efficient things that they had not done before. Most people were motivated by the desire to do the right thing and to set a good example for their children. They were less motivated by other factors.

  6. Grid Load Shifting and Performance Assessments of Residential Efficient Energy Technologies, a Case Study in Japan

    Directory of Open Access Journals (Sweden)

    Yanxue Li

    2018-06-01

    Full Text Available The increasing penetration of renewable energy decreases grid flexibility; thus, decentralized energy management or demand response are emerging as the main approaches to resolve this limitation and to provide flexibility of resources. This research investigates the performance of high energy efficiency appliances and grid-integrated distributed generators based on real monitored data from a social demonstration project. The analysis not only explores the potential cost savings and environmental benefits of high energy efficiency systems in the private sector, but also evaluates public grid load leveling potential from a bottom-up approach. This research provides a better understanding of the behavior of high decentralized efficient energy and includes detailed scenarios of monitored power generation and consumption in a social demonstration project. The scheduled heat pump effectively lifts valley load via transforming electricity to thermal energy, its daily electricity consumption varies from 4 kWh to 10 kWh and is concentrated in the early morning over the period of a year. Aggregated vehicle to home (V2H brings flexible resources to the grid, by discharging energy to cover the residential night peak load, with fuel cost savings attributed to 90% of profit. The potential for grid load leveling via integrating the power utility and consumer is examined using a bottom-up approach. Five hundred thousand contributions from scheduled electrical vehicles (EVs and fuel cells provide 5.0% of reliable peak power capacity at 20:00 in winter. The outcome illustrates the energy cost saving and carbon emission reduction scenarios of each of the proposed technologies. Relevant subsidies for heat pump water heater systems and cogeneration are essential customers due to the high initial capital investment. Optimal mixes in structure and coordinated control of high efficiency technologies enable customers to participate in grid load leveling in terms of

  7. Measurement error in mobile source air pollution exposure estimates due to residential mobility during pregnancy.

    Science.gov (United States)

    Pennington, Audrey Flak; Strickland, Matthew J; Klein, Mitchel; Zhai, Xinxin; Russell, Armistead G; Hansen, Craig; Darrow, Lyndsey A

    2017-09-01

    Prenatal air pollution exposure is frequently estimated using maternal residential location at the time of delivery as a proxy for residence during pregnancy. We describe residential mobility during pregnancy among 19,951 children from the Kaiser Air Pollution and Pediatric Asthma Study, quantify measurement error in spatially resolved estimates of prenatal exposure to mobile source fine particulate matter (PM 2.5 ) due to ignoring this mobility, and simulate the impact of this error on estimates of epidemiologic associations. Two exposure estimates were compared, one calculated using complete residential histories during pregnancy (weighted average based on time spent at each address) and the second calculated using only residence at birth. Estimates were computed using annual averages of primary PM 2.5 from traffic emissions modeled using a Research LINE-source dispersion model for near-surface releases (RLINE) at 250 m resolution. In this cohort, 18.6% of children were born to mothers who moved at least once during pregnancy. Mobile source PM 2.5 exposure estimates calculated using complete residential histories during pregnancy and only residence at birth were highly correlated (r S >0.9). Simulations indicated that ignoring residential mobility resulted in modest bias of epidemiologic associations toward the null, but varied by maternal characteristics and prenatal exposure windows of interest (ranging from -2% to -10% bias).

  8. Do homes that are more energy efficient consume less energy?: A structural equation model of the English residential sector

    International Nuclear Information System (INIS)

    Kelly, Scott

    2011-01-01

    Energy consumption from the residential sector is a complex socio-technical problem that can be explained using a combination of physical, demographic and behavioural characteristics of a dwelling and its occupants. A structural equation model (SEM) is introduced to calculate the magnitude and significance of explanatory variables on residential energy consumption. The benefit of this approach is that it explains the complex relationships that exist between manifest variables and their overall effect though direct, indirect and total effects. Using the English House Condition Survey (EHCS) consisting of 2531 unique cases, the main drivers behind residential energy consumption are found to be the number of household occupants, floor area, household income, dwelling efficiency (SAP), household heating patterns and living room temperature. In the multivariate case, SAP explains very little of the variance of residential energy consumption. However, this procedure fails to account for simultaneity bias between energy consumption and SAP. Using SEM its shown that dwelling energy efficiency (SAP), has reciprocal causality with dwelling energy consumption and the magnitude of these two effects are calculable. When non-recursivity between SAP and energy consumption is allowed for, SAP is shown to have a negative effect on energy consumption but conversely, homes with a propensity to consume more energy also have higher SAP rates. -- Highlights: → A Structural Equation Model (SEM) is developed to explain residential energy demand. → Key variables that drive residential energy consumption are empirically identified. → Direct, indirect and total effects are determined. → It is found that occupancy and household income are strongly mediated by floor area. → A non-recursive relationship is found to exist between energy consumption and SAP.

  9. Assessing energy techniques and measures in residential buildings: a multidisciplinary perspective

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus

    2013-01-01

    Many Energy Techniques and Measures (ETMs) are available to reduce the fossil energy use of residential buildings. However, the rate at which these ETMs are implemented is relatively low. Bram Entrop (1980) addresses, in this design-oriented research, the influence that ETMs have on the energy

  10. Transforming the market for residential windows: design considerations for DOE's Efficient Window Collaborative

    Energy Technology Data Exchange (ETDEWEB)

    Eto, J.; Arasteh, D.; Selkowitz, S.

    1998-08-01

    Market adoption of recent, commercially available technological advances that improve the energy performance of windows will lead to immediate economic and energy savings benefits to the nation. This paper is a scoping study intended to inform the design of a major DOE initiative to accelerate market adoption of these windows in the residential sector. We describe the structure of the US residential window market and the interests of the various market players. We then briefly review five recent market transformation initiatives. Finally, we summarize our findings in a list of considerations we believe will be important for the DOE's initiative to transform the US residential window market.

  11. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  12. The Consortium of Advanced Residential Buildings (CARB) - A Building America Energy Efficient Housing Partnership

    Energy Technology Data Exchange (ETDEWEB)

    Robb Aldrich; Lois Arena; Dianne Griffiths; Srikanth Puttagunta; David Springer

    2010-12-31

    This final report summarizes the work conducted by the Consortium of Advanced Residential Buildings (CARB) (http://www.carb-swa.com/), one of the 'Building America Energy Efficient Housing Partnership' Industry Teams, for the period January 1, 2008 to December 31, 2010. The Building America Program (BAP) is part of the Department of Energy (DOE), Energy Efficiency and Renewable Energy, Building Technologies Program (BTP). The long term goal of the BAP is to develop cost effective, production ready systems in five major climate zones that will result in zero energy homes (ZEH) that produce as much energy as they use on an annual basis by 2020. CARB is led by Steven Winter Associates, Inc. with Davis Energy Group, Inc. (DEG), MaGrann Associates, and Johnson Research, LLC as team members. In partnership with our numerous builders and industry partners, work was performed in three primary areas - advanced systems research, prototype home development, and technical support for communities of high performance homes. Our advanced systems research work focuses on developing a better understanding of the installed performance of advanced technology systems when integrated in a whole-house scenario. Technology systems researched included: - High-R Wall Assemblies - Non-Ducted Air-Source Heat Pumps - Low-Load HVAC Systems - Solar Thermal Water Heating - Ventilation Systems - Cold-Climate Ground and Air Source Heat Pumps - Hot/Dry Climate Air-to-Water Heat Pump - Condensing Boilers - Evaporative condensers - Water Heating CARB continued to support several prototype home projects in the design and specification phase. These projects are located in all five program climate regions and most are targeting greater than 50% source energy savings over the Building America Benchmark home. CARB provided technical support and developed builder project case studies to be included in near-term Joule Milestone reports for the following community scale projects: - SBER Overlook at

  13. Forecasting jobs in the supply chain for investments in residential energy efficiency retrofits in Florida

    Science.gov (United States)

    Fobair, Richard C., II

    This research presents a model for forecasting the numbers of jobs created in the energy efficiency retrofit (EER) supply chain resulting from an investment in upgrading residential buildings in Florida. This investigation examined material supply chains stretching from mining to project installation for three product types: insulation, windows/doors, and heating, ventilating, and air conditioning (HVAC) systems. Outputs from the model are provided for the project, sales, manufacturing, and mining level. The model utilizes reverse-estimation to forecast the numbers of jobs that result from an investment. Reverse-estimation is a process that deconstructs a total investment into its constituent parts. In this research, an investment is deconstructed into profit, overhead, and hard costs for each level of the supply chain and over multiple iterations of inter-industry exchanges. The model processes an investment amount, the type of work and method of contracting into a prediction of the number of jobs created. The deconstruction process utilizes data from the U.S. Economic Census. At each supply chain level, the cost of labor is reconfigured into full-time equivalent (FTE) jobs (i.e. equivalent to 40 hours per week for 52 weeks) utilizing loaded labor rates and a typical employee mix. The model is sensitive to adjustable variables, such as percentage of work performed per type of product, allocation of worker time per skill level, annual hours for FTE calculations, wage rate, and benefits. This research provides several new insights into job creation. First, it provides definitions that can be used for future research on jobs in supply chains related to energy efficiency. Second, it provides a methodology for future investigators to calculate jobs in a supply chain resulting from an investment in energy efficiency upgrades to a building. The methodology used in this research is unique because it examines gross employment at the sub-industry level for specific

  14. Country Review of Energy-Efficiency Financial Incentives in the Residential Sector

    Energy Technology Data Exchange (ETDEWEB)

    Can, Stephane de la Rue du; Shah, Nihar; Phadke, Amol

    2011-07-13

    A large variety of energy-efficiency policy measures exist. Some are mandatory, some are informative, and some use financial incentives to promote diffusion of efficient equipment. From country to country, financial incentives vary considerably in scope and form, the type of framework used to implement them, and the actors that administer them. They range from rebate programs administered by utilities under an Energy-Efficiency Resource Standards (EERS) regulatory framework (California, USA) to the distribution of Eco-points rewarding customers for buying highly efficient appliances (Japan). All have the primary objective of transforming the current market to accelerate the diffusion of efficient technologies by addressing up-front cost barriers faced by consumers; in most instances, efficient technologies require a greater initial investment than conventional technologies. In this paper, we review the different market transformation measures involving the use of financial incentives in the countries belonging to the Major Economies Forum. We characterize the main types of measures, discuss their mechanisms, and provide information on program impacts to the extent that ex-ante or ex-post evaluations have been conducted. Finally, we identify best practices in financial incentive programs and opportunities for coordination between Major Economies Forum countries as envisioned under the Super Efficient Appliance Deployment (SEAD) initiative.

  15. Targeting energy justice: Exploring spatial, racial/ethnic and socioeconomic disparities in urban residential heating energy efficiency

    International Nuclear Information System (INIS)

    Reames, Tony Gerard

    2016-01-01

    Fuel poverty, the inability of households to afford adequate energy services, such as heating, is a major energy justice concern. Increasing residential energy efficiency is a strategic fuel poverty intervention. However, the absence of easily accessible household energy data impedes effective targeting of energy efficiency programs. This paper uses publicly available data, bottom-up modeling and small-area estimation techniques to predict the mean census block group residential heating energy use intensity (EUI), an energy efficiency proxy, in Kansas City, Missouri. Results mapped using geographic information systems (GIS) and statistical analysis, show disparities in the relationship between heating EUI and spatial, racial/ethnic, and socioeconomic block group characteristics. Block groups with lower median incomes, a greater percentage of households below poverty, a greater percentage of racial/ethnic minority headed-households, and a larger percentage of adults with less than a high school education were, on average, less energy efficient (higher EUIs). Results also imply that racial segregation, which continues to influence urban housing choices, exposes Black and Hispanic households to increased fuel poverty vulnerability. Lastly, the spatial concentration and demographics of vulnerable block groups suggest proactive, area- and community-based targeting of energy efficiency assistance programs may be more effective than existing self-referral approaches. - Highlights: • Develops statistical model to predict block group (BG) residential heating energy use intensity (EUI), an energy efficiency proxy. • Bivariate and multivariate analyses explore racial/ethnic and socioeconomic relationships with heating EUI. • BGs with more racial/ethnic minority households had higher heating EUI. • BGs with lower socioeconomics had higher heating EUI. • Mapping heating EUI can facilitate effective energy efficiency intervention targeting.

  16. Direct and indirect co-benefits from energy-efficient residential buildings

    International Nuclear Information System (INIS)

    Ott, W.; Baur, M.; Jakob, M.

    2006-01-01

    Co-benefits of energy efficiency investments such as increased comfort of living, reduced noise exposure, and improved indoor air quality are of considerable evidence. However in investment decisions these co-benefits are rarely taken into account. Using various economic estimation methods (discrete choice, hedonic regression, contingent valuation), this study identifies and quantifies in monetary terms the most important co-benefits of energy efficiency measures. The results show that regarding energy efficiency measures, comfort of living plays a major role and that inhabitants express a non-negligible willingness to pay for it. The willingness to pay is larger than the costs of the energy efficiency measures in most cases and for a large part of the population. To utilise this willingness to pay in the market place it is necessary to establish transparency regarding comfort-of-living aspects and to raise awareness about these aspects among all involved actors (inhabitants, investors, architects, planners, promoters, vendors) by adequate information and communication measures. In view of the high relevance and the noticed economic valuation of the qualitative co-benefits, energy efficiency measures have to be promoted with their related enhancements in terms of comfort of living. (author)

  17. Direct and indirect co-benefits from energy-efficient residential buildings - Appendix

    International Nuclear Information System (INIS)

    Ott, W.; Baur, M.; Jakob, M.

    2006-01-01

    Co-benefits of energy efficiency investments such as increased comfort of living, reduced noise exposure, and improved indoor air quality are of considerable evidence. However in investment decisions these co-benefits are rarely taken into account. Using various economic estimation methods (discrete choice, hedonic regression, contingent valuation), this study identifies and quantifies in monetary terms the most important co-benefits of energy efficiency measures. The results show that regarding energy efficiency measures, comfort of living plays a major role and that inhabitants express a non-negligible willingness to pay for it. The willingness to pay is larger than the costs of the energy efficiency measures in most cases and for a large part of the population. To utilise this willingness to pay in the market place it is necessary to establish transparency regarding comfort of living aspects and to raise awareness about these aspect among all involved actors (inhabitants, investors, architects, planners, promoters, vendors) by adequate information and communication measures. In view of the high relevance and the noticed economic valuation of the qualitative co-benefits energy efficiency measures have to be promoted with their related enhancements in terms of comfort of living. (author)

  18. Cost-effectiveness of high-efficiency appliances in the U.S. residential sector: A case study

    International Nuclear Information System (INIS)

    McNeil, Michael A.; Bojda, Nicholas

    2012-01-01

    This paper presents an analysis of the cost-effectiveness of high-efficiency appliances in the U.S. residential sector using cost and efficiency data developed as part of the regulatory process of the U.S. Department of Energy's Appliances and Commercial Equipment Standards Program. These data are presented as a case study in the development of an ‘efficiency technology database’ which can be expanded and published as a resource to other researchers and policy makers seeking scenarios that optimize efficiency policies and forecast their likely impacts on energy demand and greenhouse gas emissions. The use of this data to evaluate cost-effectiveness according to a variety of metrics is demonstrated using the example of one refrigerator–freezer product class. Cost-effectiveness is then evaluated in terms of cost of conserved energy for refrigerators, room air conditioners, water heaters, cooking equipment, central air conditioners and gas furnaces. The resulting potential of cost-effective improvement ranges from 1% to 53% of energy savings, with a typical potential of 15–20%. - Highlights: ► We determined the potential for cost-effective efficiency for residential appliances. ► We cover 6 appliance groups using cost of conserved energy as a metric for cost-effectiveness. ► Data are source from the DOE's Appliance and Commercial Equipment Standards Program. ► Between 15% and 20% additional cost-effective efficiency improvement is possible.

  19. Renewable energy and conservation measures for non-residential buildings

    Science.gov (United States)

    Grossman, Andrew James

    The energy demand in most countries is growing at an alarming rate and identifying economically feasible building retrofit solutions to decrease the need for fossil fuels so as to mitigate their environmental and societal impacts has become imperative. Two approaches are available for identifying feasible retrofit solutions: 1) the implementation of energy conservation measures; and 2) the production of energy from renewable sources. This thesis focuses on the development of retrofit software planning tools for the implementation of solar photovoltaic systems, and lighting system retrofits for mid-Michigan institutional buildings. The solar planning tool exploits the existing blueprint of a building's rooftop, and via image processing, the layouts of the solar photovoltaic arrays are developed based on the building's geographical location and typical weather patterns. The resulting energy generation of a PV system is estimated and is utilized to determine levelized energy costs. The lighting system retrofit analysis starts by a current utilization assessment of a building to determine the amount of energy used by the lighting system. Several LED lighting options are evaluated on the basis of color correlation temperature, color rendering index, energy consumption, and financial feasibility, to determine a retrofit solution. Solar photovoltaic installations in mid-Michigan are not yet financially feasible, but with the anticipated growth and dynamic complexity of the solar photovoltaic market, this solar planning tool is able to assist building proprietors make executive decisions regarding their energy usage. Additionally, a lighting system retrofit is shown to have significant financial and health benefits.

  20. Strategies for carbon dioxide emissions reductions: Residential natural gas efficiency, economic, and ancillary health impacts in Maryland

    International Nuclear Information System (INIS)

    Ruth, Matthias; Blohm, Andrew; Mauer, Joanna; Gabriel, Steven A.; Kesana, Vijay G.; Chen Yihsu; Hobbs, Benjamin F.; Irani, Daraius

    2010-01-01

    As part of its commitments to the Regional Greenhouse Gas Initiative (RGGI), the State of Maryland, USA, auctions emission permits to electric utilities, creating revenue that can be used to benefit consumers and the environment. This paper explores the CO 2 emissions reductions that may be possible by allocating some of that revenue to foster efficiency improvements in the residential sector's use of natural gas. Since these improvements will require changes to the capital stock of houses and end use equipment, efficiency improvements may be accompanied by economic and ancillary health impacts, both of which are quantified in this paper.

  1. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, Joseph [Building Science Corporation, Westford, MA (United States)

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamily units that satisfies the requirements of ASHRAE 62.2-2016.

  2. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  3. A measure to manage approach to characterizing the energy impact of residential building stocks

    Directory of Open Access Journals (Sweden)

    Afamia Elnakat

    2016-05-01

    Full Text Available The city of San Antonio is the seventh largest in the United States by population and the second in the state of Texas, with a population of over 1.3 million people. As one of the fastest growing cities, the San Antonio residential real estate market has expanded to meet the demands of the growing population. Managing the energy footprint of single-family houses can be enhanced by big data analysis of combined metered energy consumption and building infrastructure characteristics. This study analyzes the energy intensity of 389,160 single family detached homes and identifies energy utilization trends across various residential building stock size and vintage categories. Supported by the “measure to manage” premise, this study highlights the value of this characterization as a forecasting and planning tool for sustainable growth and a more engaged consumer.

  4. Response of residential electricity demand to price: The effect of measurement error

    International Nuclear Information System (INIS)

    Alberini, Anna; Filippini, Massimo

    2011-01-01

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: → Updated information on price elasticities for the US energy policy. → Taking into account measurement error in the price variable increase price elasticity. → Room for discouraging residential electricity consumption using price increases.

  5. Response of residential electricity demand to price: The effect of measurement error

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, Anna [Department of Agricultural Economics, University of Maryland (United States); Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Gibson Institute and Institute for a Sustainable World, School of Biological Sciences, Queen' s University Belfast, Northern Ireland (United Kingdom); Filippini, Massimo, E-mail: mfilippini@ethz.ch [Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Department of Economics, University of Lugano (Switzerland)

    2011-09-15

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: > Updated information on price elasticities for the US energy policy. > Taking into account measurement error in the price variable increase price elasticity. > Room for discouraging residential electricity consumption using price increases.

  6. Residential Energy Efficiency Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rutter, A. [Sustainability Solutions LLC (Guam); Briggs, D. [Naval Base Guam, Santa Rita (Guam)

    2014-03-01

    In order to meet its energy goals, the Department of Defense (DOD) has partnered with the Department of Energy (DOE) to rapidly demonstrate and deploy cost-effective renewable energy and energy-efficiency technologies. The scope of this project was to demonstrate tools and technologies to reduce energy use in military housing, with particular emphasis on measuring and reducing loads related to consumer electronics (commonly referred to as 'plug loads'), hot water, and whole-house cooling.

  7. Conceptual provisions of the implementation of energy saving measures in the residential facilities

    Directory of Open Access Journals (Sweden)

    Meshcheryakova Tatiana

    2017-01-01

    Full Text Available Research purpose is identification of sales problems of energy saving actions for residential sector of economy, including with use of the power service contract. The choice of the object of the study is related to the general issues on energy saving of residential facilities and increasing the number of unresolved problems. Unfortunately, the efficiency of energy consumption of housing stock is extremely low that directly leads to an increase in citizens’ payments for public utilities (housing and communal services. There are many problems associated with the aging of fixed assets: it becomes especially evident in winter seasons. The level of quality of delivery, distribution and consumption of expensive heat resources that has the greatest impact on a residence comfort and sometimes human life and health, is very low. Our population faces to year overheating or freezing, to leakages through worn pipes and the subsequent disconnection of water and heat. Despite the public declaration of the of the active processes of modernization of the housing municipal economy in the Russian Federation, the implementation of the necessary energy-saving elements in the housing sector is evolving very slowly. The article presents conceptual positions, which will bring the issues related to energy saving and efficiency to a new level.

  8. Objectively measured residential environment and self-reported health: a multilevel analysis of UK census data.

    Directory of Open Access Journals (Sweden)

    Frank Dunstan

    Full Text Available Little is known about the association between health and the quality of the residential environment. What is known is often based on subjective assessments of the environment rather than on measurements by independent observers. The aim of this study, therefore, was to determine the association between self-reported general health and an objectively assessed measure of the residential environment. We studied over 30,000 residents aged 18 or over living in 777 neighbourhoods in south Wales. Built environment quality was measured by independent observers using a validated tool, the Residential Environment Assessment Tool (REAT, at unit postcode level. UK Census data on each resident, which included responses to a question which assessed self-reported general health, was linked to the REAT score. The Census data also contained detailed information on socio-economic and demographic characteristics of all respondents and was also linked to the Welsh Index of Multiple Deprivation. After adjusting for both the individual characteristics and area deprivation, respondents in the areas of poorest neighbourhood quality were more likely to report poor health compared to those living in areas of highest quality (OR 1.36, 95% confidence interval 1.22-1.49. The particular neighbourhood characteristics associated with poor health were physical incivilities and measures of how well the residents maintained their properties. Measures of green space were not associated with self-reported health. This is the first full population study to examine such associations and the results demonstrate the importance for health of the quality of the neighbourhood area in which people live and particularly the way in which residents behave towards their own and their neighbours' property. A better understanding of causal pathways that allows the development of interventions to improve neighbourhood quality would offer significant potential health gains.

  9. An Exploration of the Relationship between Improvements in Energy Efficiency and Life-Cycle Energy and Carbon Emissions using the BIRDS Low-Energy Residential Database.

    Science.gov (United States)

    Kneifel, Joshua; O'Rear, Eric; Webb, David; O'Fallon, Cheyney

    2018-02-01

    To conduct a more complete analysis of low-energy and net-zero energy buildings that considers both the operating and embodied energy/emissions, members of the building community look to life-cycle assessment (LCA) methods. This paper examines differences in the relative impacts of cost-optimal energy efficiency measure combinations depicting residential buildings up to and beyond net-zero energy consumption on operating and embodied flows using data from the Building Industry Reporting and Design for Sustainability (BIRDS) Low-Energy Residential Database. Results indicate that net-zero performance leads to a large increase in embodied flows (over 40%) that offsets some of the reductions in operational flows, but overall life-cycle flows are still reduced by over 60% relative to the state energy code. Overall, building designs beyond net-zero performance can partially offset embodied flows with negative operational flows by replacing traditional electricity generation with solar production, but would require an additional 8.34 kW (18.54 kW in total) of due south facing solar PV to reach net-zero total life-cycle flows. Such a system would meet over 239% of operational consumption of the most energy efficient design considered in this study and over 116% of a state code-compliant building design in its initial year of operation.

  10. Residential energy-efficient technology adoption, energy conservation, knowledge, and attitudes: An analysis of European countries

    International Nuclear Information System (INIS)

    Mills, Bradford; Schleich, Joachim

    2012-01-01

    Relationships between measures of household energy use behavior and household characteristics are estimated using a unique dataset of approximately 5000 households in 10 EU countries and Norway. Family age-composition patterns are found to have a distinct impact on household energy use behavior. Households with young children are more likely to adopt energy-efficient technologies and energy conservation practices and place primary importance on energy savings for environmental reasons. By contrast, households with a high share of elderly members place more importance on financial savings, and have lower levels of technology adoption, energy conservation practice use, and knowledge about household energy use. Education levels also matter, with higher levels associated with energy-efficient technology adoption and energy conservation practice use. Similarly, university education increases the stated importance of energy savings for greenhouse gas reductions and decreases the stated importance for financial reasons. Education impacts also vary greatly across survey countries and there is some evidence of an Eastern–Western European divide with respect to attitudes towards energy savings. These cross-country differences highlight the need to balance a common EU energy-efficiency policy framework with flexibility for country specific policies to address unique constraints to energy-efficient technology and conservation practice adoption. - Highlights: ► Household energy use behavior is explored with data from 11 European countries. ► Household age structure and education influence household energy use behavior and attitudes. ► Significant country differences in household energy use behavior exist. ► The EU needs to balance a common energy-efficiency policy framework with country specific policies.

  11. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  12. Energy saving in residential and tertiary sectors: regulations, inciting measures and consumer attitude

    International Nuclear Information System (INIS)

    Arnaud, P.; Aubert, D.; Grel, P.; Herant, P.; Molia, J.P.; Thelinge, H.

    2007-01-01

    Energy saving regulations in the residential and tertiary sectors are under permanent evolution. What are the most significant rules already existing and under preparation? What is the position of the natural gas industry with respect to this regulatory environment? Is there more specific regulatory measures that would be needed to reach the CO 2 abatement goals? What are the means to sensibilize consumers? What are the contributions of the building industry and of energy services? This workshop gathered five experts and a chairman who debated these different points. (J.S.)

  13. Performance Evaluation of Public-Private Partnership Projects from the Perspective of Efficiency, Economic, Effectiveness, and Equity: A Study of Residential Renovation Projects in China

    Directory of Open Access Journals (Sweden)

    Xuhui Cong

    2018-06-01

    Full Text Available The performance evaluation index system was established on the basis of 4E (Efficiency, Economic, Effectiveness, Equity theory to improve performance evaluation of Public-Private Partnership Projects for Residential Renovation (4P2R. Moreover, the index weighting model was demonstrated based on Ordered Weighted Averaging (OWA. Finally, the cloud model was used for performance evaluation, through the cloud uncertainty reasoning to determine the quantitative performance evaluation index value, the positive reverse cloud to calculate the qualitative performance evaluation index value, and the normal cloud to measure the project performance. The proof-of-concept application shows that the performance evaluation index system and evaluation model can better identify the deficiencies in the project, and provide targeted improvement measures for similar projects in the future.

  14. A novel field measurement method for determining fine particle and gas emissions from residential wood combustion

    Science.gov (United States)

    Tissari, Jarkko; Hytönen, Kati; Lyyränen, Jussi; Jokiniemi, Jorma

    Emission data from residential wood combustion are usually obtained on test stands in the laboratory but these measurements do not correspond to the operational conditions in the field because of the technological boundary conditions (e.g. testing protocol, environmental and draught conditions). The field measurements take into account the habitual practice of the operators and provide the more reliable results needed for emission inventories. In this study, a workable and compact method for measuring emissions from residential wood combustion in winter conditions was developed. The emissions for fine particle, gaseous and PAH compounds as well as particle composition in real operational conditions were measured from seven different appliances. The measurement technique worked well and was evidently suitable for winter conditions. It was easy and fast to use, and no construction scaffold was needed. The dilution of the sample with the combination of a porous tube diluter and an ejector diluter was well suited to field measurement. The results indicate that the emissions of total volatile organic carbon (TVOC) (17 g kg -1 (of dry wood burned)), carbon monoxide (CO) (120 g kg -1) and fine particle mass (PM 1) (2.7 g kg -1) from the sauna stove were higher than in the other measured appliances. In the masonry heaters, baking oven and stove, the emissions were 2.9-9 g kg -1 TVOC, 28-68 g kg -1 CO and 0.6-1.6 g kg -1 PM 1. The emission of 12 PAHs (PAH 12) from the sauna stove was 164 mg kg -1 and consisted mainly of PAHs with four benzene rings in their structure. PAH 12 emission from other appliances was, on average, 21 mg kg -1 and was dominated by 2-ring PAHs. These results indicate that despite the non-optimal operational practices in the field, the emissions did not differ markedly from the laboratory measurements.

  15. Predicting personal exposure to airborne carbonyls using residential measurements and time/activity data

    Science.gov (United States)

    Liu, Weili; Zhang, Junfeng (Jim); Korn, Leo R.; Zhang, Lin; Weisel, Clifford P.; Turpin, Barbara; Morandi, Maria; Stock, Tom; Colome, Steve

    As a part of the Relationships of Indoor, Outdoor, and Personal Air (RIOPA) study, 48 h integrated residential indoor, outdoor, and personal exposure concentrations of 10 carbonyls were simultaneously measured in 234 homes selected from three US cities using the Passive Aldehydes and Ketones Samplers (PAKS). In this paper, we examine the feasibility of using residential indoor concentrations to predict personal exposures to carbonyls. Based on paired t-tests, the means of indoor concentrations were not different from those of personal exposure concentrations for eight out of the 10 measured carbonyls, indicating indoor carbonyls concentrations, in general, well predicted the central tendency of personal exposure concentrations. In a linear regression model, indoor concentrations explained 47%, 55%, and 65% of personal exposure variance for formaldehyde, acetaldehyde, and hexaldehyde, respectively. The predictability of indoor concentrations on cross-individual variability in personal exposure for the other carbonyls was poorer, explainingexposure concentrations. It was found that activities related to driving a vehicle and performing yard work had significant impacts on personal exposures to a few carbonyls.

  16. Residential characteristics and radiofrequency electromagnetic field exposures from bedroom measurements in Germany

    DEFF Research Database (Denmark)

    Breckenkamp, J; Blettner, M; Schüz, J

    2012-01-01

    The objectives of this study were to assess total exposure to radiofrequency electromagnetic fields (RF-EMF) in bedrooms and the contribution of different radioservices (FM radio, analogue TV and DVB-T, TETRA, GSM900 downlink, GSM1800 downlink, UMTS downlink, DECT, and wireless LAN and blue tooth......) to the total exposure. Additional aims were to describe the proportion of measuring values above the detection limit of the dosimeters and to characterize the differences in exposure patterns associated with self-reported residential characteristics. Exposure to RF sources in bedrooms was measured using...... Antennessa(®) EME Spy 120 dosimeters in 1,348 households in Germany; 280 measures were available for each frequency band per household. Mean electrical field strengths and power flux densities were calculated. Power flux densities allow the calculation of proportions of different radioservices on total...

  17. Economic potential of energy-efficient retrofitting in the Swiss residential building sector: The effects of policy instruments and energy price expectations

    International Nuclear Information System (INIS)

    Amstalden, Roger W.; Kost, Michael; Nathani, Carsten; Imboden, Dieter M.

    2007-01-01

    The aim of this paper is to analyse the profitability of energy-efficient retrofit investments in the Swiss residential building sector from the house owner's perspective. Different energy price expectations, policy instruments such as subsidies, income tax deduction and a carbon tax, as well as potential future cost degression of energy efficiency measures were taken into account. The discounted cash flow method was used for the investment analysis of different retrofit packages applied to a model building scheduled for renovation, i.e. a single-family house constructed between 1948 and 1975. The results show that present Swiss policy instruments push investments for energy-efficient retrofitting to profitability. Cost degression has a minor significance for investment profitability. However, the most relevant factor for the investment analysis is the expected energy price. Expecting a future fuel oil price at the level of 2005, efficiency investments are close to profitability even without policy support. If higher energy prices were expected, energy-efficient retrofitting would be an attractive investment opportunity

  18. Energy Efficiency Modelling of Residential Air Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Cong Toan Tran

    2016-03-01

    Full Text Available The heat pump water heater is one of the most energy efficient technologies for heating water for household use. The present work proposes a simplified model of coefficient of performance and examines its predictive capability. The model is based on polynomial functions where the variables are temperatures and the coefficients are derived from the Australian standard test data, using regression technics. The model enables to estimate the coefficient of performance of the same heat pump water heater under other test standards (i.e. US, Japanese, European and Korean standards. The resulting estimations over a heat-up phase and a full test cycle including a draw off pattern are in close agreement with the measured data. Thus the model allows manufacturers to avoid the need to carry out physical tests for some standards and to reduce product cost. The limitations of the methodology proposed are also discussed.

  19. Do measures matter? Comparing surface-density-derived and census-tract-derived measures of racial residential segregation

    Directory of Open Access Journals (Sweden)

    Waller Lance A

    2010-06-01

    Full Text Available Abstract Background Racial residential segregation is hypothesized to affect population health by systematically patterning health-relevant exposures and opportunities according to individuals' race or income. Growing interest into the association between residential segregation and health disparities demands more rigorous appraisal of commonly used measures of segregation. Most current studies rely on census tracts as approximations of the local residential environment when calculating segregation indices of either neighborhoods or metropolitan areas. Because census tracts are arbitrary in size and shape, reliance on this geographic scale limits understanding of place-health associations. More flexible, explicitly spatial derivations of traditional segregation indices have been proposed but have not been compared with tract-derived measures in the context of health disparities studies common to social epidemiology, health demography, or medical geography. We compared segregation measured with tract-derived as well as GIS surface-density-derived indices. Measures were compared by region and population size, and segregation measures were linked to birth record to estimate the difference in association between segregation and very preterm birth. Separate analyses focus on metropolitan segregation and on neighborhood segregation. Results Across 231 metropolitan areas, tract-derived and surface-density-derived segregation measures are highly correlated. However overall correlation obscures important differences by region and metropolitan size. In general the discrepancy between measure types is greatest for small metropolitan areas, declining with increasing population size. Discrepancies in measures are greatest in the South, and smallest in Western metropolitan areas. Choice of segregation index changed the magnitude of the measured association between segregation and very preterm birth. For example among black women, the risk ratio for very

  20. Energize New York -- Residential Energy Efficiency Market Transformation in New York

    Energy Technology Data Exchange (ETDEWEB)

    Bregman, Thomas M.

    2013-12-31

    Energize New York (ENY) is focused on addressing known barriers to widespread energy efficiency (EE) adoption by property owners. In simple terms ENY works to; 1) increase homeowner trust by using known and trusted community leaders to communicate their own positive experiences with EE and ENY, 2) reduce friction points by integrating support staff and creative use of technology that ease a homeowner’s way forward through the EE upgrade process, 3) increase homeowner knowledge and trust of specific EE benefits through access to the ENY energy coach, 4) provide information on available financing options that show benefits (e.g. positive cash flow), and 5) provide tools and mechanisms that give homeowners greater comfort in evaluating and selecting the right contractor. These five fundamental program aspects are supported by a hyper-local communications and outreach model and a “lead by example” philosophy that requires community leaders to step forward and model energy efficiency behavior by example. In the communities where the program has successfully engaged local leadership and “trusted community sources” there has been a significant increase in the uptake of energy efficiency work. Quantitatively this growth translated into an increase of 240% in completed Home Performance projects from the two year pre-pilot period (2009-10) to the two year post-pilot period (2012-13). Additionally, the program has seen measureable increases in the output and performance of contractors who are members of the Energize Comfort Corps, a program innovation which included a subset of the NYSERDA approved and Building Performance Institute accredited home performance contractors. This innovation, launched in the later stages of the pilot, is paired with the Energize Contractor Ratings Index (CRI) and helps frame the provider market by giving homeowners a mechanism to provide and receive feedback on their contractor experience. The data incorporated into the CRI along with

  1. Inter-relationships between objective and subjective measures of the residential environment among urban African American women.

    Science.gov (United States)

    Sealy-Jefferson, Shawnita; Messer, Lynne; Slaughter-Acey, Jaime; Misra, Dawn P

    2017-03-01

    The inter-relationships between objective (census based) and subjective (resident reported) measures of the residential environment is understudied in African American (AA) populations. Using data from the Life Influences on Fetal Environments Study (2009-2011; n = 1387) of AA women, we quantified the area-level variation in subjective reports of residential healthy food availability, walkability, safety, and disorder that can be accounted for with an objective neighborhood disadvantage index (NDI). Two-level generalized linear models estimated associations between objective and subjective measures of the residential environment, accounting for individual-level covariates. In unconditional models, intraclass correlation coefficients for block-group variance in subjective reports ranged from 11% (healthy food availability) to 30% (safety). Models accounting for the NDI (vs. both NDI and individual-level covariates) accounted for more variance in healthy food availability (23% vs. 8%) and social disorder (40% vs. 38%). The NDI and individual-level variables accounted for 39% and 51% of the area-level variation in walkability and safety, respectively. Associations between subjective and objective measures of the residential environment were significant and in the expected direction. Future studies on neighborhood effects on health, especially among AAs, should include a wide range of residential environment measures, including subjective, objective, and spatial contextual variables. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Cost-benefit assessment of energy efficiency investments: Accounting for future resources, savings and risks in the Australian residential sector

    International Nuclear Information System (INIS)

    Morrissey, J.; Meyrick, B.; Sivaraman, D.; Horne, R.E.; Berry, M.

    2013-01-01

    This article focuses on the impact of the discount rate on cost-benefit assessment of investment options for residential building efficiency. An integrated thermal modeling, life cycle costing approach is applied to an extensive sample of dominant house designs for Australian conditions. The relative significance of predicted thermal performance and the applied discount rate on the Present Value of energy savings from alternative investment scenarios is investigated. Costs and benefits are also evaluated at the economy-wide scale, including carbon pricing considerations, and for a test-case household faced with alternative investment options at the point of construction. The influence of the applied discount rate on produced cost-benefit calculations is investigated, as is the interaction between critical cost-benefit input parameters. Findings support that the discounting framework is the primary driver of difference in estimates about costs and benefits of higher standards of efficiency in the residential sector. Results demonstrate that agreement on a low discount rate based on sustainability principals would prioritise those projects with significant environmental benefits. - Highlights: ► High thermal efficiency is a key strategy to limit energy use in buildings. ► Integrated thermal modeling—life-cycle costing methods are applied to dominant house designs. ► The discounting framework is the primary driver of difference in observed costs. ► The selection of optimal performance investment options depends on the discount rate. ► Application of a discount rate of 3.5% or lower favours energy saving projects

  3. ENERGY-EFFICIENT REGIMES FOR HEATING-SUPPLY OF THE RESIDENTIAL BUILDINGS

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2015-01-01

    Full Text Available Rise in comfort and inhabitation safety is one of the main requirements of the general maintenance, reconstruction of the old and construction of the new residential houses. One of the essential factors of it is substitution in the household hot-water preparing sources: from the individual domestic gas  water-heaters to  the common  entire-building hot-water supply at the expense of the centralized heat supply. Extremely erratic hot-water daily consumption by tenants leads to the necessity of sharp increase in central heat-supply level during a few hours of the day, which requires a significant increase of the source heat-power. On that score, the authors propose to direct a significant part (up to 50 % of the centralized heating and ventilation heat power-consumption to the hot water preparation during the period of short-term hot water consumption peak.Substitution  of  the  individual  domestic  gas  water-heaters  with  the  common  entirebuilding hot-water supply releases a huge amount of natural gas which can be utilized not only for production of the necessary heat power but as well for electric power producing. This substitution is especially advantageous if heat-power is delivered to the residential area from a НРС where significant part of heat especially in a relatively warm season of the year is thrown out into the air. The content of the article is based on several patents received earlier.

  4. Willingness to pay for energy-saving measures in residential buildings

    International Nuclear Information System (INIS)

    Banfi, Silvia; Farsi, Mehdi; Jakob, Martin; Filippini, Massimo

    2008-01-01

    This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)

  5. 76 FR 57612 - Energy Efficiency Program for Consumer Products: Test Procedures for Residential Refrigerators...

    Science.gov (United States)

    2011-09-15

    ...-Freezers, and Freezers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy... FURTHER INFORMATION CONTACT: Mr. Lucas Adin, U.S. Department of Energy, Office of Energy Efficiency and... public comments, contact Ms. Brenda Edwards, U.S. Department of Energy, Office of Energy Efficiency and...

  6. Priorities for energy efficiency measures in agriculture

    NARCIS (Netherlands)

    Visser, de C.L.M.

    2013-01-01

    This report provides research gaps and priorities for energy efficiency measures in agriculture across Europe, based on the analysis of the Coordination and Support Action AGREE (Agriculture & Energy Efficiency) funded by the 7th research framework of the EU (www.agree.aua.gr). The analysis from

  7. Measurement Of Technical Efficiency In Irrigated Vegetable ...

    African Journals Online (AJOL)

    This study measured technical efficiency and identified its determinants in irrigated vegetable production in Nasarawa State of Nigeria using a stochastic frontier model. A complete enumeration of 193 NADP-registered vegetable farmers was done. The predicted farm technical efficiency ranges from 25.94 to 96.24 per cent ...

  8. Turkey’s Strategic Energy Efficiency Plan – An ex ante impact assessment of the residential sector

    International Nuclear Information System (INIS)

    Elsland, Rainer; Divrak, Can; Fleiter, Tobias; Wietschel, Martin

    2014-01-01

    Turkey’s energy demand has been growing by 4.5% per year over the last decade. As a reaction to this, the Turkish government has implemented the Strategic Energy Efficiency Plan (SEEP), which provides a guideline for energy efficiency policies in all sectors. The aim of this study is to analyse the potential of the SEEP on final energy demand in the Turkish residential sector until 2030. Three scenarios are developed based on a detailed bottom-up modelling approach using a vintage stock model to simulate the energy demand of heating systems and appliances. The results show a decreasing final energy demand in the reference scenario from about 944 PJ in 2008 to 843 PJ in 2030. This reflects a structural break, which is mainly caused by a high building demolition rate and low efficiency in the existing building stock. The SEEP achieves additional savings of around 111 PJ until 2030, while a scenario with even higher efficiency shows further savings of 91 PJ. Electricity demand increases in all scenarios – mainly due to growing ownership rates of appliances. The SEEP will achieve around 10 TWh of electricity savings in 2030 compared to the reference scenario, mainly through more ambitious end-use standards

  9. Achievements and suggestions of heat metering and energy efficiency retrofit for existing residential buildings in northern heating regions of China

    International Nuclear Information System (INIS)

    Yan Ding; Zhe Tian; Yong Wu; Neng Zhu

    2011-01-01

    In order to promote energy efficiency and emission reduction, the importance of improving building energy efficiency received sufficient attention from Chinese Government. The heat metering and energy efficiency retrofit for existing residential buildings of 0.15 billion m 2 in northern heating regions of China was initiated in 2007 and completed successfully at the end of 2010. This article introduced the background and outline of the retrofit project during the period of 11th five-year plan. Numerous achievements that received by retrofit such as environmental protection effect, improvement of indoor environment, improvement of heating system, investment guidance effect, promotion of relevant industries and increasing chances of employment were concluded. Valuable experience that acquired from the retrofit project during the period of 11th five-year plan was also summarized in this article. By analyzing the main problems emerged in the past, pertinent suggestions were put forward to promote a larger scale and more efficient retrofit project in the period of 12th five-year plan. - Highlights: →Successful implementation of a retrofit project in China is introduced. → Significance of the project contributing to emission reduction is analyzed. →Achievements are summarized and future suggestions are put forward.

  10. Fiscal and tax policy support for energy efficiency retrofit for existing residential buildings in China's northern heating region

    International Nuclear Information System (INIS)

    Li Dongyan

    2009-01-01

    Energy efficiency retrofit for existing residential buildings (EERERB) in China's northern heating region is an important component of the national energy strategy. The main content and related subject in EERERB performance is the basis of understanding and developing targeted policies. So, this paper designed the content system of EERERB. And then, provided a cost-benefit analysis on related subjects, assessed the government's function in EERERB, and come to the conclusion that the Chinese government should increase fiscal fund investment and implement more fiscal and tax incentive policies. Moreover, in view of China's current policy, which lacks long-term mechanism and flexibility, this paper proposed specific policy recommendations, including clarifying the government's corresponding responsibilities at all levels and increasing the intensity of the central government's transfer payments. It further proposed targeted financial and tax policies for supporting and encouraging heating enterprises and owners, as well as policies to cultivate energy-saving service markets and to support the ESCO.

  11. Energy Efficiency and Sustainability Evaluation of Space and Water Heating in Urban Residential Buildings of the Hot Summer and Cold Winter Zone in China

    OpenAIRE

    Xiao Chen; Yongquan Wen; Nanyang Li

    2016-01-01

    With the urbanization process of the hot summer and cold winter (HSCW) zone in China, the energy consumption of space and water heating in urban residential buildings of the HSCW zone has increased rapidly. This study presents the energy efficiency and sustainability evaluation of various ways of space and water heating taking 10 typical cities in the HSCW zone as research cases. Two indicators, primary energy efficiency (PEE) and sustainability index based on exergy efficiency, are adopted t...

  12. Walking beam pumping unit system efficiency measurements

    International Nuclear Information System (INIS)

    Kilgore, J.J.; Tripp, H.A.; Hunt, C.L. Jr.

    1991-01-01

    The cost of electricity used by walking beam pumping units is a major expense in producing crude oil. However, only very limited information is available on the efficiency of beam pumping systems and less is known about the efficiency of the various components of the pumping units. This paper presents and discusses measurements that have been made on wells at several Shell locations and on a specially designed walking beam pump test stand at Lufkin Industries. These measurements were made in order to determine the overall system efficiency and efficiency of individual components. The results of this work show that the overall beam pumping system efficiency is normally between 48 and 58 percent. This is primarily dependent on the motor size, motor type, gearbox size, system's age, production, pump size, tubing size, and rod sizes

  13. Measuring cardiac efficiency using PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grand [Lawrence Berkeley National Laboratory (United States); Aparici, Carina Mari; Brooks, Gabriel [University of California San Francisco (United States); Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes [Lawrence Berkeley National Laboratory (United States)

    2015-05-18

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  14. Measuring cardiac efficiency using PET/MRI

    International Nuclear Information System (INIS)

    Gullberg, Grand; Aparici, Carina Mari; Brooks, Gabriel; Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes

    2015-01-01

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  15. Energy efficiency of lighting systems in residential buildings; Energieeffizienzsteigerung der Beleuchtungstechnik in Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Troeger, Andreas [Technische Univ. Dresden (Germany). Elektrotechnisches Inst.; Wittig, Michael; Schlosser, Roman; Wuerfel, Matthias [Westsaechsische Hochschule Zwickau (Germany). Fakultaet Elektrotechnik

    2011-07-01

    Due to political demands such as the law of an eco-friendly-design of Energy Using Products (EBPG), the production and thus the long-term use of conventional light bulbs is no longer possible within the European Union. Energy saving light bulbs are preferred as replacement for those bulbs. However, these lighting systems have unfavourable properties for certain areas of applications, such as low luminance during the heating phase or a low lifetime if used under strongly fluctuating stress. Therefore, using conventional light bulbs in stairwells, their properties are of great disadvantage. The paper examines possible applications for LED lighting systems (Light Emitting Diode), meeting the standards. Investigations of possible on-demand switching or dimming of LED lighting have been executed with the help of presence or movement sensors and by using smart grids such as the KNX-compliant components. Furthermore, technical requirements, economic viability and energetic advantages and disadvantages of separate DC power networks for the operating of the LED lights have been tested. Since energy storage increased in rental buildings, the storage system DC supply can be used for DC power of such consumers. In this way, the AC and the rectifier losses can be avoided and thus the energy efficiency of lighting can be increased in rental buildings. To implement the project a model of a staircase has been created by using the simulation software DIALux. Furthermore the given lighting conditions have been measured in the stairwell. Thus, the staircase model yields comparative results. (orig.)

  16. Life-cycle cost analysis of energy efficiency design options for residential furnaces and boilers

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, J.; Lekov, A.; Chan, P.; Dunham Whitehead, C.; Meyers, S.; McMahon, J. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States). Environmental Energy Technologies Div.

    2006-03-01

    In 2001, the US Department of Energy (DOE) initiated a rulemaking process to consider whether to amend the existing energy efficiency standards for furnaces and boilers. A key factor in DOE's consideration of new standards is the economic impacts on consumers of possible revisions to energy-efficiency standards. Determining cost-effectiveness requires an appropriate comparison of the additional first cost of energy efficiency design options with the savings in operating costs. DOE's preferred approach involves comparing the total life-cycle cost (LCC) of owning and operating a more efficient appliance with the LCC for a baseline design. This study describes the method used to conduct the LCC analysis and presents the estimated change in LCC associated with more energy-efficient equipment. The results indicate that efficiency improvement relative to the baseline design can reduce the LCC in each of the product classes considered. (author)

  17. Life-cycle cost analysis of energy efficiency design options for residential furnaces and boilers

    International Nuclear Information System (INIS)

    Lutz, James; Lekov, Alex; Chan, Peter; Whitehead, Camilla Dunham; Meyers, Steve; McMahon, James

    2006-01-01

    In 2001, the US Department of Energy (DOE) initiated a rulemaking process to consider whether to amend the existing energy efficiency standards for furnaces and boilers. A key factor in DOE's consideration of new standards is the economic impacts on consumers of possible revisions to energy-efficiency standards. Determining cost-effectiveness requires an appropriate comparison of the additional first cost of energy efficiency design options with the savings in operating costs. DOE's preferred approach involves comparing the total life-cycle cost (LCC) of owning and operating a more efficient appliance with the LCC for a baseline design. This study describes the method used to conduct the LCC analysis and presents the estimated change in LCC associated with more energy-efficient equipment. The results indicate that efficiency improvement relative to the baseline design can reduce the LCC in each of the product classes considered

  18. Future air conditioning energy consumption in developing countries and what can be done about it: the potential of efficiency in the residential sector

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Letschert, Virginie E. [Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory (United States)

    2007-07-01

    The dynamics of air conditioning are of particular interest to energy analysts, both because of the high energy consumption of this product, but also its disproportionate impact on peak load. This paper addresses the special role of this end use as a driver of residential electricity consumption in rapidly developing economies. Recent history has shown that air conditioner ownership grows more rapidly than economic growth in warm-climate countries. In 1990, less than a percent of urban Chinese households owned an air conditioner; by 2003 this number rose to 62 %. The evidence suggests a similar explosion of air conditioner use in many other countries is not far behind. Room air conditioner purchases in India are currently growing at 20 % per year, with about half of these purchases attributed to the residential sector. This paper draws on two distinct methodological elements to assess future residential air conditioner 'business as usual' electricity consumption by country/region and to consider specific alternative 'high efficiency' scenarios. The first component is an econometric ownership and use model based on household income, climate and demographic parameters. The second combines ownership forecasts and stock accounting with geographically specific efficiency scenarios within a unique analysis framework (BUENAS) developed by LBNL. The efficiency scenario module considers current efficiency baselines, available technologies, and achievable timelines for development of market transformation programs, such as minimum efficiency performance standards (MEPS) and labeling programs. The result is a detailed set of consumption and emissions scenarios for residential air conditioning.

  19. Impact of ancestry categorisations on residential segregation measures using Swedish register data.

    Science.gov (United States)

    Jarvis, Benjamin; Kawalerowicz, Juta; Valdez, Sarah

    2017-07-01

    Country-of-birth data contained in registers are often aggregated to create broad ancestry group categories. We examine how measures of residential segregation vary according to levels of aggregation. We use Swedish register data to calculate pairwise dissimilarity indices from 1990 to 2012 for ancestry groups defined at four nested levels of aggregation: (1) micro-groups containing 50 categories, (2) meso-groups containing 16 categories, (3) macro-groups containing six categories and (4) a broad Western/non-Western binary. We find variation in segregation levels between ancestry groups that is obscured by data aggregation. This study demonstrates that the practice of aggregating country-of-birth statistics in register data can hinder the ability to identify highly segregated groups and therefore design effective policy to remedy both intergroup and intergenerational inequalities.

  20. Phase Change Materials as a solution to improve energy efficiency in Portuguese residential buildings

    Science.gov (United States)

    Araújo, C.; Pinheiro, A.; Castro, M. F.; Bragança, L.

    2017-10-01

    The buildings sector contributes to 30% of annual greenhouse gas emissions and consumes about 40% of energy. However, this consumption can be reduced by between 30% and 80% through commercially available technologies. The consumption of energy in the dwellings is mostly associated with the heating and cooling of the interior environment. One solution to reduce these consumptions is the implementation of technologies and Phase Change Materials (PCMs) for Thermal Energy Storage (TES). So, the aim of this work is to analyse the advantages, in terms of decreasing energy consumption, associated with the application of PCMs in Portuguese residential buildings. For this, eight PCMs with different melting ranges were analysed. These materials were analysed through a dynamic simulation performed with EnergyPlus software. The results achieved, showed that the materials studied allow to reduce up to 13% of the heating needs and up to 92% of the cooling needs of a building located in the North of Portugal, at an altitude higher than 100m.

  1. A Canadian loan fund for residential energy efficiency and renewable energy

    International Nuclear Information System (INIS)

    Tampier, M.

    2008-01-01

    Financing is a major need in the residential sector. Only a few programs in Canada provide low-interest financing for renewable energy. This presentation discussed the leveraging of cheap capital that could be used to enable public and private offers. With financial incentives, the renewable energy market was expected to at least double. A financial incentive fund could be one of several tools to achieve net zero energy housing, and address fuel poverty. A business plan is also required to move closer towards realization. The presentation described a report that outlines similar programs within and outside Canada, and presented estimates on future market size. Key data that was provided in the presentation included market potential; start-up capital for the fund; and average loan size to intermediaries. Next steps were also discussed with particular reference to lobbying the federal government to pick up this idea; having provincial governments and utilities join in this effort; and involvement of industry associations who have a tangible product. 1 fig

  2. Efficient quantum computing with weak measurements

    International Nuclear Information System (INIS)

    Lund, A P

    2011-01-01

    Projective measurements with high quantum efficiency are often assumed to be required for efficient circuit-based quantum computing. We argue that this is not the case and show that the fact that they are not required was actually known previously but was not deeply explored. We examine this issue by giving an example of how to perform the quantum-ordering-finding algorithm efficiently using non-local weak measurements considering that the measurements used are of bounded weakness and some fixed but arbitrary probability of success less than unity is required. We also show that it is possible to perform the same computation with only local weak measurements, but this must necessarily introduce an exponential overhead.

  3. Measuring social climate in Norwegian residential youth care : A revision of the community oriented programs environment scale

    NARCIS (Netherlands)

    Leipoldt, Jonathan David; Rimehaug, Tormod; Harder, A.T.; Kayed, Nanna; Grietens, Hans

    2016-01-01

    Introduction and objectives: Social climate is an understudied factor in residential youth care (RYC) institutions. Already in the 1950’s, the World Health Organization stated that “atmosphere” is an important factor in psychiatric treatment, but a very difficult element to measure. Assessing the

  4. Combined heat and power and thermally insulating measures in residential housing stock; Kraft-Waerme-Kopplung und Daemmmassnahmen im Wohngebaeudebestand

    Energy Technology Data Exchange (ETDEWEB)

    Buller, Michael [Gas- und Waerme-Institut Essen e.V., Essen (Germany)

    2013-02-15

    The author of the contribution under consideration reports on the economic, ecologic and primary energetic potential of micro-combined heat and power (micro-CHP) in the residential housing stock under consideration of possible correlations between CHP and thermally insulating measures.

  5. In-situ real time measurements of thermal comfort and comparison with the adaptive comfort theory in Dutch residential dwellings

    NARCIS (Netherlands)

    Ioannou, A.; Itard, L.C.M.; Agarwal, Tushar

    2018-01-01

    Indoor thermal comfort is generally assessed using the PMV or the adaptive model. This research presents the results obtained by in-situ real time measurements of thermal comfort and thermal comfort perception in 17 residential dwellings in the Netherlands. The study demonstrates the new

  6. Measures for energy efficiency improvement of buildings

    Directory of Open Access Journals (Sweden)

    Vukadinović Ana V.

    2015-01-01

    Full Text Available The increase in energy consumption in buildings causes the need to propose energy efficiency improvement measures. Urban planning in accordance with micro location conditions can lead to energy consumption reduction in buildings through the passive solar design. While satisfying the thermal comfort to the user space purpose, energy efficiency can be achieved by optimizing the architectural and construction parameters such as shape of the building, envelope structure and the percentage of glazing. The improvement of the proposed measures, including the use of renewable energy sources, can meet requirements of Directive 2010/31 / EU of 'nearly zero energy buildings'.

  7. An Efficient Approach for Energy Consumption Optimization and Management in Residential Building Using Artificial Bee Colony and Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    Fazli Wahid

    2016-01-01

    Full Text Available The energy management in residential buildings according to occupant’s requirement and comfort is of vital importance. There are many proposals in the literature addressing the issue of user’s comfort and energy consumption (management with keeping different parameters in consideration. In this paper, we have utilized artificial bee colony (ABC optimization algorithm for maximizing user comfort and minimizing energy consumption simultaneously. We propose a complete user friendly and energy efficient model with different components. The user set parameters and the environmental parameters are inputs of the ABC, and the optimized parameters are the output of the ABC. The error differences between the environmental parameters and the ABC optimized parameters are inputs of fuzzy controllers, which give the required energy as the outputs. The purpose of the optimization algorithm is to maximize the comfort index and minimize the error difference between the user set parameters and the environmental parameters, which ultimately decreases the power consumption. The experimental results show that the proposed model is efficient in achieving high comfort index along with minimized energy consumption.

  8. The role of energy and investment literacy for residential electricity demand and end-use efficiency

    NARCIS (Netherlands)

    Blasch, J.E.; Boogen, Nina; Filippini, Massimo; Kumar, Nilkanth

    2017-01-01

    This paper estimates the level of transient and persistent efficiency in the use of electricity in Swiss households using the newly developed generalized true random effects model (GTREM). An unbalanced panel dataset of 1, 994 Swiss households from 2010 to 2014 collected via a household survey is

  9. SiC-based High Efficiency Bidirectional Battery Converter for Smart PV Residential Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Biris, Valeriu-Ciprian; Teodorescu, Remus

    2013-01-01

    Smart PV inverters are essential components of future grids. Beside conventional functionalities they can communicate with the grid, supports the grid with reactive power and with active power from internal battery storage. To maximize internal consumption, a high efficiency bidirectional DC-DC c...

  10. High efficiency battery converter with SiC devices for residential PV systems

    DEFF Research Database (Denmark)

    Pham, Cam; Teodorescu, Remus; Kerekes, Tamas

    2013-01-01

    The demand for high efficiency and higher power density is a challenge for Si-based semiconductors due to the physical characteristics of material. These can be overcome by employing wide-band-gap materials like SiC. This paper compares a second generator SiC MOSFETs against a normally-on Trench...

  11. A framework to characterize energy efficiency measures

    International Nuclear Information System (INIS)

    Trianni, Andrea; Cagno, Enrico; De Donatis, Alessio

    2014-01-01

    Highlights: • A novel framework to characterize energy efficiency measures is proposed. • It allows a greater knowledge sharing, facilitating the adoption of the best measures. • It supports policy-makers in developing drivers for industrial energy efficiency. - Abstract: The need to increase the diffusion of energy efficiency measures (EEMs) is of crucial importance to achieve a consistent reduction of energy consumption and green house gases (GHG) emissions. A clear comprehension of the characteristics of such EEMs could assist in gathering and capitalizing all the information needed by industrial firms in selecting and adopting technologies, as well as by policy-makers in designing appropriate policies for their diffusion. Therefore, in this study, starting from a literature review of the studies analyzing the attributes of EEMs, we aim at providing an innovative and comprehensive framework to characterize such measures, based on 17 attributes grouped according to six categories, such as: economic, energy, environmental, production-related, implementation-related and the possible interaction with other systems. We applied this scheme to an extensive range of EEMs in cross-cutting technologies, i.e. motors, compressed air, lighting and HVAC systems. The analysis provides a relevant contribution firstly to the structuring and the sharing of knowledge on EEMs and hence to the comprehension of the barriers currently hindering their adoption; secondly, it provides a structured basis for the analysis of the drivers that policy-makers should develop in order to promote industrial energy efficiency

  12. Environmental and energy efficiency evaluation of residential gas and heat pump heating

    International Nuclear Information System (INIS)

    Ganji, A.R.

    1993-01-01

    Energy efficiency and source air pollutant emission factors of gas heaters, gas engine heat pumps, and electric heat pumps for domestic heating have been evaluated and compared. The analysis shows that with the present state of technology, gas engine heat pumps have the highest energy efficiency followed by electric heat pumps and then gas heaters. Electric heat pumps produce more than twice as much NO x , and comparable CO 2 and CO per unit of useful heating energy compared to natural gas heaters. CO production per unit of useful heating energy from gas engine heat pumps without any emission control is substantially higher than electric heat pumps and natural gas heaters. NO x production per unit of useful heating energy from natural gas engine heat pumps (using lean burn technology) without any emission control is about the same as effective NO x production from electric heat pumps. Gas engine heat pumps produce about one-half CO 2 compared to electric heat pumps

  13. Valuing energy-saving measures in residential buildings. A choice experiment study

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, So-Yoon; Kwak, Seung-Jun [Department of Economics, Korea University, 5-1 Anam-Dong, Seoul 136-701 (Korea); Yoo, Seung-Hoon [Department of International Area Studies, Hoseo University, 268 Anseo-Dong, Cheonan, Chungnam 330-713 (Korea)

    2010-01-15

    Air-conditioning and heating energy-saving measures can cut back the usage of energy. This paper attempts to apply a choice experiment in evaluating the consumer's willingness to pay (WTP) for air-conditioning and heating energy-saving measures in Korea's residential buildings. We consider the trade-offs between price and three attributes of energy-saving (window, facade, and ventilation) for selecting a preferred alternative and derive the marginal WTP (MWTP) estimate for each attribute. We also try to test irrelevant alternatives property for the estimation model holds and compare the estimation results of the multinomial logit (MNL) and the nested logit (NL) models. The NL model outperforms the MNL model. The NL model show that MWTPs for increasing the number of glasses and their variety, for increasing the thickness of facade for 1 mm, and for establishing a ventilation system are KRW 17,392 (USD 18.2), 1,112 (1.2), and 11,827 (12.4), respectively. Overall, the potential consumers have significant amount of WTP. (author)

  14. Productivity benefits of industrial energy efficiency measures

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, Ernst; Laitner, John A.; Michael, Ruth; Finman, Hodayah

    2004-08-30

    We review the relationship between energy efficiency improvement measures and productivity in industry. We review over 70 industrial case studies from widely available published databases, followed by an analysis of the representation of productivity benefits in energy modeling. We propose a method to include productivity benefits in the economic assessment of the potential for energy efficiency improvement. The case-study review suggests that energy efficiency investments can provide a significant boost to overall productivity within industry. If this relationship holds, the description of energy-efficient technologies as opportunities for larger productivity improvements has significant implications for conventional economic assessments. The paper explores the implications this change in perspective on the evaluation of energy-efficient technologies for a study of the iron and steel industry in the US. This examination shows that including productivity benefits explicitly in the modeling parameters would double the cost-effective potential for energy efficiency improvement, compared to an analysis excluding those benefits. We provide suggestions for future research in this important area.

  15. Racial Residential Segregation: Measuring Location Choice Attributes of Environmental Quality and Self-Segregation

    Directory of Open Access Journals (Sweden)

    Zhaohua Zhang

    2018-04-01

    Full Text Available Both sorting on public goods and tastes for segregation contribute to the persistence of segregation in America. Incorporating Schelling’s (1969, 1971 concept of “neighborhood tipping” into a two-stage equilibrium sorting model, in which both neighborhood demographic composition and public goods (e.g., environmental quality affect households’ residential location choice, this study investigates how preferences for neighborhood demographic composition could obscure the role of exogenous public goods on segregation. The results reveal that non-white households face higher level of exposure to air pollution, suggesting the presence of environmental injustice in Franklin County, OH. Using a counterfactual scenario of switching off heterogeneous taste for environmental quality, this study identifies that sorting on Toxic Release Inventory (TRI emissions drives little correlations between emissions and demographics. However, when taste parameters of the interactions between neighborhood demographic composition and household race are eliminated, segregation (as measured by over-exposure to households of the same race of black and white households decreases by 7.63% and 16.36%, respectively, and own-race neighbor preferences contribute to segregation differently according to household income. These results may help explain some recent puzzles in the relationship between environmental quality and demographics.

  16. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy's Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE's Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  17. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy`s Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE`s Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  18. Marginal costs for intensified energy-efficiency measures

    International Nuclear Information System (INIS)

    Jakob, J.; Jochem, E.; Christen, K.

    2002-01-01

    The costs and benefits of investments in measures designed to improve the energy efficiency of residential buildings (in particular investments in heat insulation) were calculated as a function of increasing energy efficiency for new and renovated buildings and for single-family homes and apartment buildings. These investments in measures to improve efficiency mostly involve with the building envelope and ventilation systems and aim to successively reduce the space-heating needs of the buildings. The measures range from present-day building and renovation methods through to the 'Minergie' and 'Passive House' ('Minergie-P' in Switzerland) standards for low and very-low energy consumption buildings. Cost-benefit ratios were determined for individual building components, individual building concepts and for the whole of Switzerland, using both the average-cost as well as the pure marginal-cost methods (energy-economics level). The collection of empirical data (especially on costs) was an integral and important part of the project. The marginal costs were then compared with the benefits arising from the costs for space heating that were avoided, and, using a few typical cases as examples, with the so-called co-benefits, which are to be implemented in part by private persons and companies. For their quantification, methods were developed and used in case studies; in addition, avoided external costs are also considered. The marginal costs were also calculated for periods of time in the future, whereby they were made dynamic, according to their share of innovation, using the learning-curve method (learning and scaling effects). As far as the findings are concerned, there can be no doubt that the potential to be opened up for increasing energy efficiency using heat insulation measures is high, both for renovations and new construction work. A large portion of this potential is already economically viable and even more so when the possible risks of energy price increases

  19. Information v. energy efficiency incentives: Evidence from residential electricity consumption in Maryland

    International Nuclear Information System (INIS)

    Alberini, Anna; Towe, Charles

    2015-01-01

    We focus on two utility programs intended to reduce energy usage and the associated CO2 emissions—a home energy audit and rebates on the purchase of high-efficiency air-source heat pumps. We use a unique panel dataset from participating and non-participating households to estimate the average treatment effect of participating in either program on electricity usage. We fit models with household-by-season, season-by-year, and household-by-year fixed effects to account for all possible confounders that might influence energy usage. Since the programs are voluntary, we seek to restore near-exogeneity of the program “treatment” by matching participating households with control households. We deploy coarsened exact matching (CEM; Iacus et al., 2011) as our main matching method. We ask whether it is sufficient to match households based on past electricity usage, or if we gain by adding structural characteristics of the home, including heating system type. We find that the two programs reduce electricity usage by 5% on average. The effects are strong in both winter and summer for the energy audit groups but appear to be stronger in the winter for the heat pump rebate group. Adding house characteristics to the matching variables does seem to affect results, suggesting that using past usage alone, or house characteristics alone, may not be sufficient to identify the effects of program participation.

  20. Energy Efficiency: The Implementation of Minimum Energy Performance Standard (MEPS Application on Home Appliances for Residential

    Directory of Open Access Journals (Sweden)

    Rahman K.A

    2016-01-01

    Full Text Available Generally, Minimum Energy Performance Standard (MEPS has been widespread across the country especially developed country. However, most consumers do not even know about the MEPS. Without sufficient knowledge, much energy have been wasted before this. The aim of this study is to review the implementation of MEPS of Asia country and to compare electricity consumption of home appliances with star rating and without star rating. In order to fulfil the objectives of the study, the equipment must be chosen correctly and must be learned properly. The home appliances that will be used also need to be chosen so that the comparison between the appliances will be matched correctly. To understand the results, the analysis was done using graphs and table. The purpose of using graph and table is to understand the comparison between appliances more clearly. The results show that home appliances with MEPS is more efficient on energy saving rather than without MEPS. This is the evidence as a method to educate a consumer on energy saving.

  1. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  2. Subsidies for improving energy efficiency in residential buildings. A challenge in terms of economics and distribution policy; Subventionen zur Erhoehung der Energieeffizienz in Wohngebaeuden. Eine oekonomische und verteilungspolitische Herausforderung?

    Energy Technology Data Exchange (ETDEWEB)

    Dieckhoener, Caroline; Growitsch, Christian [Koeln Univ. (Germany). Energiewirtschaftliches Inst. (EWI)

    2013-01-15

    Improvements in the energy efficiency of buildings are seen as one of the decisive factors for the energy policy goals pursued by the EU and the German federal government. However, owners of residential buildings are showing themselves slow in taking measures for improving the energy efficiency of their properties. An obvious solution here is for the state to encourage investments by creating incentives to this end. A recent study suggests that in doing so one should distinguish between building owners and tenants and beware of bandwagon and problematic distribution effects. Furthermore, promotion measures should first of all be aimed at rental housing because this is where invested funds tend to be used most efficiently.

  3. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  4. Direct and indirect co-benefits from energy-efficient residential buildings; Direkte und indirekte Zusatznutzen bei energieeffizienten Wohnbauten

    Energy Technology Data Exchange (ETDEWEB)

    Ott, W.; Baur, M. [econcept AG, Zuerich (Switzerland); Jakob, M. [Swiss Federal Institute of Technology (ETH), Centre for Energy Policy and Economics (CEPE), Zuerich (Switzerland)

    2006-07-01

    Co-benefits of energy efficiency investments such as increased comfort of living, reduced noise exposure, and improved indoor air quality are of considerable evidence. However in investment decisions these co-benefits are rarely taken into account. Using various economic estimation methods (discrete choice, hedonic regression, contingent valuation), this study identifies and quantifies in monetary terms the most important co-benefits of energy efficiency measures. The results show that regarding energy efficiency measures, comfort of living plays a major role and that inhabitants express a non-negligible willingness to pay for it. The willingness to pay is larger than the costs of the energy efficiency measures in most cases and for a large part of the population. To utilise this willingness to pay in the market place it is necessary to establish transparency regarding comfort-of-living aspects and to raise awareness about these aspects among all involved actors (inhabitants, investors, architects, planners, promoters, vendors) by adequate information and communication measures. In view of the high relevance and the noticed economic valuation of the qualitative co-benefits, energy efficiency measures have to be promoted with their related enhancements in terms of comfort of living. (author)

  5. Residential energy efficiency: changes in household chores for women and men; Energieffektivisering i bostaden. Foeraendringar i hushaallsarbete foer kvinnor och maen

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson-Kanyama, Annika; Wulff, Petter [Swedish Defence Research Agency, Stockholm (Sweden); Linden, Anna-Lisa [Lund Univ. (Sweden)

    2005-12-15

    A substantial amount of energy is used in the residential sector. Many of the measures that residents can apply by themselves to save energy demand a change in behaviour, and thus everyday life is altered. It is common for women and men to take on different responsibilities in the household when they live together. Women spend more time on household chores and take the main responsibility for washing and cooking. In this study, we investigated how behaviour changed when women and men took part in various types of energy-saving campaigns. The data were obtained through 30 interviews in four different locations in Sweden. The results showed substantial adaptation and changes in behaviour. Examples included lowering room temperatures during the night, avoiding the use of tumble-dryers, replacing baths with showers, turning off lights, using energy-saving light bulbs, cooking and washing during hours when electricity is cheap and refitting the house for higher energy efficiency. The changes needed for this adaptation imply that women take on new responsibilities in areas that are their traditional territory, including many tasks carried out on a daily basis such as washing and drying clothes. Men often take on new responsibilities within the sphere of their traditional territory, such as building alterations or installing new equipment. These tasks are typically carried out during short periods and are mainly relevant in owner-occupied residences.

  6. Measuring and evaluating the soft energy efficiency measures. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Suvilehto, H.-M.; Solid, D. [AaF-Industry Ltd, Solna (Sweden); Rouhiainen, V. [Adato Energia Ltd, Helsinki (Finland); Honkasalo, N.; Sarvaranta, A. [AaF-Consult Ltd, Solna (Sweden)

    2012-07-15

    This study discusses how to quantify the energy savings related to the companies' aims to enhance their customers' energy efficiency which is one target in the Action Plan for Energy Services in the Energy Efficiency Agreement for the Industries. In Finland, a majority of the energy utilities have signed this action plan and are providing their customers services to improve their energy efficiency. Dissemination of information is the most widely used service to the customers and it is provided in a number of ways including printed material, annual energy report, and an internet tool to access and report hourly measurements. Some of the internet tools cover electricity, district heat and water. The focus of the study is in the evaluation of 'soft' measures; in other words, those measures given by energy utilities that principally rely on communication instruments. However, monitoring the impact of information and communication is far from easy. Carrying out a properly designed evaluation of programmes aiming on enhanced energy efficiency is difficult. Evaluation of the impact of a magazine article on energy efficiency is even more challenging, costly and therefore also rare. Distribution of information as measure to enhance energy efficiency is an important part of EU.s energy policy but what are the ways and even more so, are there ways to actually quantify these savings? There has been excessive work by the member states and research institutes to find a common and robust methodology within the EU to evaluate and quantify energy savings from technical measures. The ex-ante and ex-post results from these evaluations can however differ considerably, e.g. the expected energy savings from installing air to air heat pumps in Denmark did not deliver the expected energy savings. The problems with finding a common robust methodology become even more visible when the 'soft' measures are put under the evaluation loop. The &apos

  7. Energy efficiency policies and measures in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Eva

    2012-07-01

    This report represents the national case study of Norway for the IEE-project {sup M}onitoring of EU and national energy efficiency targets (ODYSSEE-MURE 2010)'. The Norwegian part of the project is co-funded by Enova. The report presents the recent energy efficiency trends in Norway on the basis of indicators extracted from the ODYSSEE database. The database contains information on energy use in a detailed level of the industry, transport, household and service sectors and other energy use. lt also contains information on energy drivers like heated square meters in the households and services sectors, transported passenger-km and ton-km of gods, value added, production index, production volumes etc. Final energy consumption has increased from 195 TWh in 1990 lo 229 TWh in 2010 The last ten years the energy consumption has varied between 212I Wh (2009) and 229 TWh (2010) with an annual average of 221TfUh. The sector using most energy is the industry, but the share has decreased from 40 % in 1990 to 31 % in 2010. From 1990 to 2010 the growth rate has been highest in the transport sector. Half of the energy end-use was electricity in 20,10, 42 % was fossil fuels and 6 % was biomass. The electricity use has an annual increase of 0.8 % since 1990, but the last decade the annual increase is reduced to 0.14 %. The consumption of oil products has decreased in stationary end-use (heating) and increased in the transport sector. In ODYSSEE, an aggregate bottom-up energy efficiency index, ODEX, is calculated. This energy efficiency index aggregates the trends in the detailed bottom-up indicators in one single indicator. This ODEX has improved by 26 o/o from 1990 to 2010 or by 1.3 o/o per year. This means that energy efficiency policies and measures implemented since 1990 have contributed to a decrease in the energy use of 2010 of approximately 59 TWh. (Author)

  8. A Measure of the Parent-Team Alliance in Youth Residential Psychiatry: The Revised Short Working Alliance Inventory.

    Science.gov (United States)

    Lamers, Audri; Delsing, Marc J M H; van Widenfelt, Brigit M; Vermeiren, Robert R J M

    The therapeutic alliance between multidisciplinary teams and parents within youth (semi) residential psychiatry is essential for the treatment process and forms a promising process variable for Routine Outcome Monitoring (ROM). No short evaluative instrument, however, is currently available to assess parent-team alliance. In this study, the Working Alliance Inventory-Short Version (WAV-12), a widely used alliance questionnaire, was adjusted to assess parent-team alliance from both a parent and team perspective within a youth residential setting. Psychometric properties, including factor structure and validity of the subscales, were explored. A sample of youth with mainly complex developmental disorders admitted to 11 inpatient and day patient units of a child and adolescent psychiatric institute participated in this study. The case manager involved with the youth and the primary caregiver of 87 youth completed the revised WAV-12 (WAV-12R). The team version of the WAV-12R showed a good fit to the original conceptualized model, and distinguished Bond, Task and Goal scales. For the parents' version an adjusted model with Insight, Bond and combined Task/Goal scales had the best fit. The reliability and validity of the scales were shown to be good. This paper presents preliminary evidence that the parent and treatment team versions of the WAV-12R are psychometrically sound for assessing parent-team alliance within youth (semi) residential psychiatry in the Netherlands. The team and parents' versions of the WAV-12R are recommended instruments to complement outcome measures in ROM.

  9. Improving benefit-cost analysis to overcome financing difficulties in promoting energy-efficient renovation of existing residential buildings in China

    International Nuclear Information System (INIS)

    Wang, Xiaotong; Lu, Meijun; Mao, Wei; Ouyang, Jinlong; Zhou, Bo; Yang, Yunkai

    2015-01-01

    Highlights: • Financing difficulties hinder energy retrofit of aging residential buildings in China. • New indices based on benefit-cost analysis are presented to overcome barriers. • New indices can be applied to rank energy measures and propose optimum plans. • Improved benefit-cost analysis will attract the government and residents to co-invest. • A “win–win” model means the governments and residents can co-invest and co-benefit. - Abstract: Energy-efficient renovation of existing residential buildings is an important energy policy in China, but financing difficulties seriously hinder the promotion of the policy. In this article, novel indices based on benefit-cost analysis are presented to overcome the barriers. Firstly, benefit-cost analysis is expanded to include the ratio of energy-saving benefit to investment cost (EnIR), the ratio of environmental benefit to investment cost (EvIR), and the ratio of economic benefit to investment cost (EcIR). The above ratios are applied to determine the optimum plans with the highest cost-effectiveness for the buildings to be renovated. Secondly, according to the actual situation regarding both the government and residents, EnIR is modified to the ratio of energy-saving benefit from the retrofit plan to the part of the investment cost undertaken by the government (EnIgR), EvIR to the ratio of environmental benefit from the retrofit plan to the part of the investment cost undertaken by the government (EvIgR), and EcIR to the ratio of economic benefit from the retrofit plan to the part of the investment cost undertaken by residents (EcIrR). The modified ratios can increase awareness of residents in respect of their individual benefits from the adoption of the optimum plans, and can attract them to co-invest. Through these two steps, financing difficulties could be eased or even no longer considered as obstacles to some extent. The ratios are applied to a case study building in Hangzhou. Based on the results

  10. Energy Efficiency and Sustainability Evaluation of Space and Water Heating in Urban Residential Buildings of the Hot Summer and Cold Winter Zone in China

    Directory of Open Access Journals (Sweden)

    Xiao Chen

    2016-09-01

    Full Text Available With the urbanization process of the hot summer and cold winter (HSCW zone in China, the energy consumption of space and water heating in urban residential buildings of the HSCW zone has increased rapidly. This study presents the energy efficiency and sustainability evaluation of various ways of space and water heating taking 10 typical cities in the HSCW zone as research cases. Two indicators, primary energy efficiency (PEE and sustainability index based on exergy efficiency, are adopted to perform the evaluation. Models for the energy and total exergy efficiencies of various space and water heating equipment/systems are developed. The evaluation results indicate that common uses of electricity for space and water heating are the most unsustainable ways of space and water heating. In terms of PEE and sustainability index, air-source heat pumps for space and water heating are suitable for the HSCW zone. The PEE and sustainability index of solar water heaters with auxiliary electric heaters are greatly influenced by local solar resources. Air-source heat pump assisted solar hot water systems are the most sustainable among all water heating equipment/systems investigated in this study. Our works suggest the key potential for improving the energy efficiency and the sustainability of space and water heating in urban residential buildings of the HSCW zone.

  11. Target-oriented obstacle analysis by PESTEL modeling of energy efficiency retrofit for existing residential buildings in China's northern heating region

    Energy Technology Data Exchange (ETDEWEB)

    Shilei, Lv [School of Environment Science and Technology, Tianjin University, Tianjin 300072 (China); Yong, Wu [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China)

    2009-06-15

    According to the 'Comprehensive Work Program of Energy Efficiency and Emission Reduction' of the Chinese government, during the period of the '11th Five-Year Plan', 1.5 x 10{sup 8} m{sup 2} of existing residential buildings in China's northern heating region are to be retrofitted for energy efficiency. However, at present, this 'Energy Efficiency Retrofit for Existing Residential Buildings' (EERFERB) faces many obstacles. Under the current working and market system, both the central and local governments and the energy supply companies can not push on this work smoothly. Using both the results of the annual national special inspection of building energy efficiency and some case analyses, this paper examines the necessity for energy efficiency retrofit, along with the relationships among the various Political, Economic, Social, Technological, Environmental and Legal (PESTEL) factors affecting it. Furthermore, organizational, financial and technical support systems are explored to promote the development of retrofit. Finally, some primary principles to be followed toward the implementation of EERFERB are suggested. (author)

  12. Target-oriented obstacle analysis by PESTEL modeling of energy efficiency retrofit for existing residential buildings in China's northern heating region

    International Nuclear Information System (INIS)

    Shilei, Lv; Wu Yong

    2009-01-01

    According to the 'Comprehensive Work Program of Energy Efficiency and Emission Reduction' of the Chinese government, during the period of the '11th Five-Year Plan', 1.5x10 8 m 2 of existing residential buildings in China's northern heating region are to be retrofitted for energy efficiency. However, at present, this 'Energy Efficiency Retrofit for Existing Residential Buildings' (EERFERB) faces many obstacles. Under the current working and market system, both the central and local governments and the energy supply companies can not push on this work smoothly. Using both the results of the annual national special inspection of building energy efficiency and some case analyses, this paper examines the necessity for energy efficiency retrofit, along with the relationships among the various Political, Economic, Social, Technological, Environmental and Legal (PESTEL) factors affecting it. Furthermore, organizational, financial and technical support systems are explored to promote the development of retrofit. Finally, some primary principles to be followed toward the implementation of EERFERB are suggested.

  13. Measure Guideline. Energy-Efficient Window Performance and Selection

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, John [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR; Haglund, Kerry [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR

    2012-11-01

    This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all U.S. climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The report also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well.

  14. Primary emissions and secondary aerosol production potential from woodstoves for residential heating: Influence of the stove technology and combustion efficiency

    Science.gov (United States)

    Bertrand, Amelie; Stefenelli, Giulia; Bruns, Emily A.; Pieber, Simone M.; Temime-Roussel, Brice; Slowik, Jay G.; Prévôt, André S. H.; Wortham, Henri; El Haddad, Imad; Marchand, Nicolas

    2017-11-01

    To reduce the influence of biomass burning on air quality, consumers are encouraged to replace their old woodstove with new and cleaner appliances. While their primary emissions have been extensively investigated, the impact of atmospheric aging on these emissions, including secondary organic aerosol (SOA) formation, remains unknown. Here, using an atmospheric smog chamber, we aim at understanding the chemical nature and quantify the emission factors of the primary organic aerosols (POA) from three types of appliances for residential heating, and to assess the influence of aging thereon. Two, old and modern, logwood stoves and one pellet burner were operated under typical conditions. Emissions from an entire burning cycle (past the start-up operation) were injected, including the smoldering and flaming phases, resulting in highly variable emission factors. The stoves emitted a significant fraction of POA (up to 80%) and black carbon. After ageing, the total mass concentration of organic aerosol (OA) increased on average by a factor of 5. For the pellet stove, flaming conditions were maintained throughout the combustion. The aerosol was dominated by black carbon (over 90% of the primary emission) and amounted to the same quantity of primary aerosol emitted by the old logwood stove. However, after ageing, the OA mass was increased by a factor of 1.7 only, thus rendering OA emissions by the pellet stove almost negligible compared to the other two stoves tested. Therefore, the pellet stove was the most reliable and least polluting appliance out of the three stoves tested. The spectral signatures of the POA and aged emissions by a High Resolution - Time of Flight - Aerosol Mass Spectrometer (Electron Ionization (EI) at 70 eV) were also investigated. The m/z 44 (CO2+) and high molecular weight fragments (m/z 115 (C9H7+), 137 (C8H9O2+), 167 (C9H11O3+) and 181 (C9H9O4+, C14H13+)) correlate with the modified combustion efficiency (MCE) allowing us to discriminate further

  15. Future Air Conditioning Energy Consumption in Developing Countriesand what can be done about it: The Potential of Efficiency in theResidential Sector

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Letschert, Virginie E.

    2007-05-01

    The dynamics of air conditioning are of particular interestto energy analysts, both because of the high energy consumption of thisproduct, but also its disproportionate impact on peak load. This paperaddresses the special role of this end use as a driver of residentialelectricity consumption in rapidly developing economies. Recent historyhas shown that air conditioner ownership can grow grows more rapidly thaneconomic growth in warm-climate countries. In 1990, less than a percentof urban Chinese households owned an air conditioner; by 2003 this numberrose to 62 percent. The evidence suggests a similar explosion of airconditioner use in many other countries is not far behind. Room airconditioner purchases in India are currently growing at 20 percent peryear, with about half of these purchases attributed to the residentialsector. This paper draws on two distinct methodological elements toassess future residential air conditioner 'business as usual' electricityconsumption by country/region and to consider specific alternative 'highefficiency' scenarios. The first component is an econometric ownershipand use model based on household income, climate and demographicparameters. The second combines ownership forecasts and stock accountingwith geographically specific efficiency scenarios within a uniqueanalysis framework (BUENAS) developed by LBNL. The efficiency scenariomodule considers current efficiency baselines, available technologies,and achievable timelines for development of market transformationprograms, such as minimum efficiency performance standards (MEPS) andlabeling programs. The result is a detailed set of consumption andemissions scenarios for residential air conditioning.

  16. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards & Labeling Programs for Copy Machines, External Power Supplies, LED Displays, Residential Gas Cooktops and Televisions

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-03-01

    This report presents a technical review of international minimum energy performance standards (MEPS), voluntary and mandatory energy efficiency labels and test procedures for five products being considered for new or revised MEPS in China: copy machines, external power supply, LED displays, residential gas cooktops and flat-screen televisions. For each product, an overview of the scope of existing international standards and labeling programs, energy values and energy performance metrics and description and detailed summary table of criteria and procedures in major test standards are presented.

  17. Renewable Energy and Energy Efficiency Technologies in Residential Building Codes: June 15, 1998 to September 15, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Wortman, D.; Echo-Hawk, L.

    2005-02-01

    This report is an attempt to describe the building code requirements and impediments to the application of EE and RE technologies in residential buildings. Several modern model building codes were reviewed. These are representative of the codes that will be adopted by most locations in the coming years. The codes reviewed for this report include: International Residential Code, First Draft, April 1998; International Energy Conservation Code, 1998; International Mechanical Code, 1998; International Plumbing Code, 1997; International Fuel Gas Code, 1997; National Electrical Code, 1996. These codes were reviewed as to their application to (1) PV systems in buildings and building-integrated PV systems and (2) active solar domestic hot water and space-heating systems. A discussion of general code issues that impact these technologies is also included. Examples of this are solar access and sustainability.

  18. Utility residential new construction programs: Going beyond the code. A report from the Database on Energy Efficiency Programs (DEEP) Project

    Energy Technology Data Exchange (ETDEWEB)

    Vine, E.

    1995-08-01

    Based on an evaluation of 10 residential new construction programs, primarily sponsored by investor-owned utilities in the United States, we find that many of these programs are in dire straits and are in danger of being discontinued because current inclusion of only direct program effects leads to the conclusion that they are not cost-effective. We believe that the cost-effectiveness of residential new construction programs can be improved by: (1) promoting technologies and advanced building design practices that significantly exceed state and federal standards; (2) reducing program marketing costs and developing more effective marketing strategies; (3) recognizing the role of these programs in increasing compliance with existing state building codes; and (4) allowing utilities to obtain an ``energy-savings credit`` from utility regulators for program spillover (market transformation) impacts. Utilities can also leverage their resources in seizing these opportunities by forming strong and trusting partnerships with the building community and with local and state government.

  19. Trends of multiple air pollutants emissions from residential coal combustion in Beijing and its implication on improving air quality for control measures

    Science.gov (United States)

    Xue, Yifeng; Zhou, Zhen; Nie, Teng; Wang, Kun; Nie, Lei; Pan, Tao; Wu, Xiaoqing; Tian, Hezhong; Zhong, Lianhong; Li, Jing; Liu, Huanjia; Liu, Shuhan; Shao, Panyang

    2016-10-01

    Residential coal combustion is considered to be an important source of air pollution in Beijing. However, knowledge regarding the emission characteristics of residential coal combustion and the related impacts on the air quality is very limited. In this study, we have developed an emission inventory for multiple hazardous air pollutants (HAPs) associated with residential coal combustion in Beijing for the period of 2000-2012. Furthermore, a widely used regional air quality model, the Community Multi-Scale Air Quality model (CMAQ), is applied to analyze the impact of residential coal combustion on the air quality in Beijing in 2012. The results show that the emissions of primary air pollutants from residential coal combustion have basically remained the same levels during the past decade, however, along with the strict emission control imposed on major industrial sources, the contribution of residential coal combustion emissions to the overall emissions from anthropogenic sources have increased obviously. In particular, the contributions of residential coal combustion to the total air pollutants concentrations of PM10, SO2, NOX, and CO represent approximately 11.6%, 27.5%, 2.8% and 7.3%, respectively, during the winter heating season. In terms of impact on the spatial variation patterns, the distributions of the pollutants concentrations are similar to the distribution of the associated primary HAPs emissions, which are highly concentrated in the rural-urban fringe zones and rural suburb areas. In addition, emissions of primary pollutants from residential coal combustion are forecasted by using a scenario analysis. Generally, comprehensive measures must be taken to control residential coal combustion in Beijing. The best way to reduce the associated emissions from residential coal combustion is to use economic incentive means to promote the conversion to clean energy sources for residential heating and cooking. In areas with reliable energy supplies, the coal used

  20. Energy efficiency of residential buildings. Energy consumption and investment costs of different building energy standards; Energieeffizienz von Wohngebaeuden. Energieverbraeuche und Investitionskosten energetischer Gebaeudestandards

    Energy Technology Data Exchange (ETDEWEB)

    Beecken, Christoph; Schulze, Stephan [Bow Ingenieure GmbH, Braunschweig (Germany)

    2011-12-15

    In view of the impending energy transition in Germany, turning away from fossil fuels and atomic power and leading to renewable energy sources, the construction of very energy efficient new buildings gains more and more in importance. Because the saving of energy with efficient buildings offers the highest potential to achieve the energy transition without loss of comfort and also complying with the climate protection target of limitation of the carbon dioxide emission. For new buildings in the initial project planning phase, the client needs qualified consulting concerning a reasonable energy standard for his building. The consulting should comprise the multitude of energy efficiency standards and the related financial incentives and not only cover the minimum standard of the German Building Energy Conservation Regulation EnEV (Energieeinsparverordnung). But the architect can hardly quantify the potentials to reduce energy consumption of buildings considering the multitude of existing standards with multifarious effects on energy consumption, technical requirements and building costs. With the help of an example multi-storey residential building in Hannover, current energy standards for residential buildings are compared. Besides the building construction also the building services like heating, hot water generation and ventilation are considered and the most important results concerning energy consumption and investment costs are compared.

  1. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    International Nuclear Information System (INIS)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER

  2. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  3. Measure Guideline: Energy-Efficient Window Performance and Selection

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, J.; Haglund, K.

    2012-11-01

    This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all US climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The document also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well. This document is for builders, homeowners, designers and anyone making decisions about selecting energy efficient window. It is intended to complement other Building America information and efforts.

  4. Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

    Science.gov (United States)

    Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas

    2016-11-01

    This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real

  5. Comparisons of Traffic-Related Ultrafine Particle Number Concentrations Measured in Two Urban Areas by Central, Residential, and Mobile Monitoring.

    Science.gov (United States)

    Simon, Matthew C; Hudda, Neelakshi; Naumova, Elena N; Levy, Jonathan I; Brugge, Doug; Durant, John L

    2017-11-01

    Traffic-related ultrafine particles (UFP; monitoring strategies upon which the models are based have varied between studies. Our study compares particle number concentrations (PNC; a proxy for UFP) measured by three different monitoring approaches (central-site, short-term residential-site, and mobile on-road monitoring) in two study areas in metropolitan Boston (MA, USA). Our objectives were to quantify ambient PNC differences between the three monitoring platforms, compare the temporal patterns and the spatial heterogeneity of PNC between the monitoring platforms, and identify factors that affect correlations across the platforms. We collected >12,000 hours of measurements at the central sites, 1,000 hours of measurements at each of 20 residential sites in the two study areas, and >120 hours of mobile measurements over the course of ~1 year in each study area. Our results show differences between the monitoring strategies: mean one-minute PNC on-roads were higher (64,000 and 32,000 particles/cm 3 in Boston and Chelsea, respectively) compared to central-site measurements (23,000 and 19,000 particles/cm 3 ) and both were higher than at residences (14,000 and 15,000 particles/cm 3 ). Temporal correlations and spatial heterogeneity also differed between the platforms. Temporal correlations were generally highest between central and residential sites, and lowest between central-site and on-road measurements. We observed the greatest spatial heterogeneity across monitoring platforms during the morning rush hours (06:00-09:00) and the lowest during the overnight hours (18:00-06:00). Longer averaging times (days and hours vs. minutes) increased temporal correlations (Pearson correlations were 0.69 and 0.60 vs. 0.39 in Boston; 0.71 and 0.61 vs. 0.45 in Chelsea) and reduced spatial heterogeneity (coefficients of divergence were 0.24 and 0.29 vs. 0.33 in Boston; 0.20 and 0.27 vs. 0.31 in Chelsea). Our results suggest that combining stationary and mobile monitoring may lead

  6. Comparisons of traffic-related ultrafine particle number concentrations measured in two urban areas by central, residential, and mobile monitoring

    Science.gov (United States)

    Simon, Matthew C.; Hudda, Neelakshi; Naumova, Elena N.; Levy, Jonathan I.; Brugge, Doug; Durant, John L.

    2017-11-01

    Traffic-related ultrafine particles (UFP; strategies upon which the models are based have varied between studies. Our study compares particle number concentrations (PNC; a proxy for UFP) measured by three different monitoring approaches (central-site, short-term residential-site, and mobile on-road monitoring) in two study areas in metropolitan Boston (MA, USA). Our objectives were to quantify ambient PNC differences between the three monitoring platforms, compare the temporal patterns and the spatial heterogeneity of PNC between the monitoring platforms, and identify factors that affect correlations across the platforms. We collected >12,000 h of measurements at the central sites, 1000 h of measurements at each of 20 residential sites in the two study areas, and >120 h of mobile measurements over the course of ∼1 year in each study area. Our results show differences between the monitoring strategies: mean 1 min PNC on-roads were higher (64,000 and 32,000 particles/cm3 in Boston and Chelsea, respectively) compared to central-site measurements (23,000 and 19,000 particles/cm3) and both were higher than at residences (14,000 and 15,000 particles/cm3). Temporal correlations and spatial heterogeneity also differed between the platforms. Temporal correlations were generally highest between central and residential sites, and lowest between central-site and on-road measurements. We observed the greatest spatial heterogeneity across monitoring platforms during the morning rush hours (06:00-09:00) and the lowest during the overnight hours (18:00-06:00). Longer averaging times (days and hours vs. minutes) increased temporal correlations (Pearson correlations were 0.69 and 0.60 vs. 0.39 in Boston; 0.71 and 0.61 vs. 0.45 in Chelsea) and reduced spatial heterogeneity (coefficients of divergence were 0.24 and 0.29 vs. 0.33 in Boston; 0.20 and 0.27 vs. 0.31 in Chelsea). Our results suggest that combining stationary and mobile monitoring may lead to improved characterization of

  7. Technology line and case analysis of heat metering and energy efficiency retrofit of existing residential buildings in Northern heating areas of China

    International Nuclear Information System (INIS)

    Zhao Jing; Zhu Neng; Wu Yong

    2009-01-01

    The building area in northern heating areas accounting for 70% of the total land area in China is 6,500,000,000 m 2 . The average heating energy consumption in northern China is 100-200% times more than developed countries in the same latitude. This paper introduced firstly the heat metering and energy efficiency retrofit background of existing residential buildings in northern heating areas of China organized by mohurd and MOF, and then put forward the total principle and contents of retrofit. Through analyzing some retrofit cases in Germany, Poland and China, some technological experiences were summarized and finally a technology line suitable for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China which involved retrofit for heat metering and temperature regulation of heating systems, heat balance of heat source and network, and building envelope was described to provide a systematic, scientific, technological guide for the retrofit projects of 0.15 billion m 2 in 'the Eleventh Five-Year Plan' period.

  8. Energy efficient of the residential buildings based climatic condition using experimental design: a case study in malaysia

    Directory of Open Access Journals (Sweden)

    Zahraee Seyed Mojib

    2017-01-01

    Full Text Available In recent years, energy consumption has become a critical issue in the developed and developing countries. Residential buildings are one of the most users of energy in the construction sector that use the highest share of energy. This paper aims at evaluating the effect of four factors that are temperature, humidity, airflow and pressure on the cooling load in the residential buildings. To achieve this goal, statistical experimental design is used to determine the optimum setting of factors that result in optimum energy usage. Simulation software and energy analysis is used to simulate a two-storey building in Malaysia as the case of study. Final results showed that the temperature, humidity and interaction between them have the most significant effect on the energy cooling load. Moreover, to obtain the minimum value of cooling load the temperature and humidity should be equal to A=20 Celsius degree and B=60% respectively. In addition, the other two insignificant factors, airflow and pressure should be placed at the high level which are equal to C=3 cubic meters per hour, and D=6 Pascal (P respectively.

  9. Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Chang Heon Cheong

    2014-10-01

    Full Text Available Cooling load in highly glazed residential building can be excessively large due to uncontrolled solar energy entering the indoor space. This study focuses on the cooling load reduction and changes in the daylighting properties via the application of a double window system (DWS with shading with various surface reflectivities in highly glazed residential buildings. Evaluation of thermal and daylighting performances is carried out using simulation tools. The reductions in cooling load and energy cost through the use of DWS are evaluated through a comparative simulation considering conventional windows: a single window and a double window. Three variables of window types, natural ventilation, and shading reflectivity are reflected in the study. According to our results, implementation of DWS reduced cooling load by 43%–61%. Electricity cost during the cooling period was reduced by a maximum of 24%. However, a shading device setting that prioritizes effective cooling load reduction can greatly decrease the daylighting factor and luminance level of indoor space. A DWS implementing shading device with highly reflective at all surfaces is appropriate option for the more comfortable thermal and visual environment, while a shading device with low reflectivity at rear of the surface can contribute an additional 4% cooling load reduction.

  10. Comparison between predicted duct effectiveness from proposed ASHRAE Standard 152P and measured field data for residential forced air cooling systems; TOPICAL

    International Nuclear Information System (INIS)

    Siegel, Jeffrey A.; McWilliams, Jennifer A.; Walker, Iain S.

    2002-01-01

    The proposed ASHRAE Standard 152P ''Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems'' (ASHRAE 2002) has recently completed its second public review. As part of the standard development process, this study compares the forced air distribution system ratings provided by the public review draft of Standard 152P to measured field results. 58 field tests were performed on cooling systems in 11 homes in the summers of 1998 and 1999. Seven of these houses had standard attics with insulation on the attic floor and a well-vented attic space. The other four houses had unvented attics where the insulation is placed directly under the roof deck and the attic space is not deliberately vented. Each house was tested under a range of summer weather conditions at each particular site, and in some cases the amount of duct leakage was intentionally varied. The comparison between 152P predicted efficiencies and the measured results includes evaluation of the effects of weather, duct location, thermal conditions, duct leakage, and system capacity. The results showed that the difference between measured delivery effectiveness and that calculated using proposed Standard 152P is about 5 percentage points if weather data, duct leakage and air handler flow are well known. However, the accuracy of the standard is strongly dependent on having good measurements of duct leakage and system airflow. Given that the uncertainty in the measured delivery effectiveness is typically also about 5 percentage points, the Standard 152P results are acceptably close to the measured data

  11. Correlation between nutritional status and comprehensive physical performance measures among older adults with undernourishment in residential institutions

    Directory of Open Access Journals (Sweden)

    Singh DKA

    2014-08-01

    Full Text Available Devinder KA Singh,1 Zahara A Manaf,2 Noor Aini M Yusoff,3 Nur A Muhammad,2 Mei Fang Phan,1 Suzana Shahar2 1Physiotherapy Program, School of Rehabilitation Sciences, 2Nutrition and Dietetics Program, School of Health Care Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, 3ASIA Metropolitan University, Cheras, Malaysia Purpose: The consequences of combined undernourishment and decreased physical ­performance in older adults are debilitating and increases cost of care. To date, the information regarding the association between nutritional status and physical performance does not provide a complete picture. Most studies used limited or self-reported measures to evaluate physical performance. The objective of this study was to examine the correlation between nutritional status and comprehensive physical performance measures among undernourished older adults who reside in residential institutions.Methods: Forty-seven older adults (26 males, 21 females aged ≥60 (69.23±8.63 years who were identified as undernourished from two residential institutions participated in this study. A battery of physical performance tests (10 m gait speed test, dominant hand grip strength test, timed five-repetition sit-to-stand test, ten step test, arm curl test, scratch test, and respiratory muscle strength test, biochemical profiles (serum albumin, hemoglobin, serum ferritin, and prealbumin levels, and falls risk using the short-form Physiological Profile Approach were performed. The Functional Ability Questionnaire and Geriatric Depression Scale were also administered.Results: The results demonstrated that generally older adults with undernourishment scored poorly on the physical performance tests, had depression, and a high risk of falls. Biochemical results demonstrated that 10.9% of the participants were anemic, 63% had hypoalbuminemia (<3.5 g/dL, and 21.7% were at risk of protein energy malnutrition with prealbumin level (100–170 mg/L. A significant

  12. Efficient Computation of Popular Phylogenetic Tree Measures

    DEFF Research Database (Denmark)

    Tsirogiannis, Constantinos; Sandel, Brody Steven; Cheliotis, Dimitris

    2012-01-01

    Given a phylogenetic tree $\\mathcal{T}$ of n nodes, and a sample R of its tips (leaf nodes) a very common problem in ecological and evolutionary research is to evaluate a distance measure for the elements in R. Two of the most common measures of this kind are the Mean Pairwise Distance ($\\ensurem...

  13. The VDEW opinion poll 2001 among residential customers - An efficient marketing research tool; VDEW-Haushaltskundenbefragung 2001 - Ein wirksames Marktforschungsinstrument

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, M. [VDEW Vereinigung Deutscher Elektrizitaetswerke e.V. Frankfurt (Germany). Bereich Markt und Daten

    2000-10-02

    Expressed in terms of company earnings, the households are the most important customer group of electric utilities. This is why the long established electricity supply companies and the newcomers in the deregulated market are building up their marketing campaigns specially designed for the residential sector. The article discusses the information drawn by the VDEW company from their latest opinion survey. (orig./CB) [German] Die Haushalte sind gemessen an den Erloesen die wichtigste Kundengruppe fuer die Stromunternehmen. Alte und neue Anbieter werben seit einem Jahr gezielt um diese Kunden. Zielgruppengerechte Werbung sowie Dienstleistungsangebote setzen Kenntnisse ueber Verbrauchsstrukturen, Meinungen und Verhaltensweisen der entsprechenden Kundengruppe voraus. Vielen Unternehmen fehlen solche detaillierte Informationen ueber ihre Haushaltskunden. Die VDEW organisiert deshalb 2001 wieder eine Haushaltskundenbefragung (HKB) - zum sechsten Mal seit 1976. (orig.)

  14. The importance of engaging residential energy customers' hearts and minds

    International Nuclear Information System (INIS)

    Olaniyan, Monisola J.; Evans, Joanne

    2014-01-01

    In an attempt to reduce the contribution of residential greenhouse gas emissions the EU has implemented a variety of policy measures. The focus has been to promote domestic energy efficiency and ultimately a reduction in residential energy demand. In this study we estimate residential energy demand using Underlying Energy Demand Trend (UEDT) and Asymmetric Price Responses for 14 European OECD countries between 1978 and 2008. Our results support the conclusion that policies to reduce residential energy consumption and the consequent emissions need to account for behavioural, lifestyle and cultural factors in order to be effective. - Highlights: • Residential energy demand is estimated for 14 European OECD countries between 1978 and 2008. • Investigate the relative contributions of Underlying Energy Demand Trend (UEDT) which captures exogenous technical progress. • The most effective policies target behavioural, lifestyle and cultural factors to reduce residential energy consumption

  15. 3-dimensional charge collection efficiency measurements using volumetric tomographic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Dobos, Daniel [CERN, Geneva (Switzerland)

    2016-07-01

    For a better understanding of the electrical field distribution of 3D semiconductor detectors and to allow efficiency based design improvements, a method to measure the 3D spatial charge collection efficiency of planar, 3D silicon and diamond sensors using 3D volumetric reconstruction techniques is possible. Simulation results and first measurements demonstrated the feasibility of this method and show that with soon available 10 times faster beam telescopes even small structures and efficiency differences will become measurable in few hours.

  16. Final Technical Report. Sault Tribe Building Efficiency Audits of Tribally-Owned Governmental Buildings and Residential Tribal Housing

    Energy Technology Data Exchange (ETDEWEB)

    Holt, Jeffrey W. [Sault Sainte Marie Tribe of Chippewa Indians, Marie, MI (United States)

    2015-03-27

    The Tribe is working to reduce energy consumption and expense in Tribally-owned governmental buildings and low income housing sites. In 2009, the Tribe applied to the U. S. Department of Energy for funding to conduct energy audits of Tribally-owned governmental buildings. Findings from the energy audits would define the extent and types of energy efficiency improvements needed, establish a basis for energy priorities, strategies and action plans, and provide a benchmark for measuring improvements from energy efficiency implementations. In 2010, the DOE awarded a grant in the amount of $95,238 to the Tribe to fund the energy audits of nine governmental buildings and to pay for travel expenses associated with attendance and participation at the DOE annual program reviews. In 2011, the Tribe applied for and was awarded a DOE grant in the amount of $75,509 to conduct energy audits of the remaining 30 Tribally-owned governmental buildings. Repeating mobilization steps performed during the first DOE energy audits grant, the Tribe initiated the second round of governmental building energy audits by completing energy auditor procurement. The selected energy auditor successfully passed DOE debarment and Sault Tribe background clearances. The energy audits contract was awarded to U. P. Engineers and Architects, Inc. of Sault Ste. Marie, Michigan. The Tribe continued mobilizing for the energy audits by providing the energy auditor with one year of electric, gas and water utility invoice copies per building, as well as supplemental building information, such as operating hours. The Tribe also contacted building occupants to coordinate scheduling for the on-site energy audit inspections and arranged for facilities management personnel to guide the energy auditor through the buildings and answer questions regarding building systems.

  17. Residential Care

    Science.gov (United States)

    ... Kids For Teens For Parents & Teachers Resolving Family Conflicts The Holidays and Alzheimer's Glossary Virtual Library Online ... longer an option Costs Choosing a care setting Types of residential care A good long-term care ...

  18. Statistical methods towards more efficient infiltration measurements.

    Science.gov (United States)

    Franz, T; Krebs, P

    2006-01-01

    A comprehensive knowledge about the infiltration situation in a catchment is required for operation and maintenance. Due to the high expenditures, an optimisation of necessary measurement campaigns is essential. Methods based on multivariate statistics were developed to improve the information yield of measurements by identifying appropriate gauge locations. The methods have a high degree of freedom against data needs. They were successfully tested on real and artificial data. For suitable catchments, it is estimated that the optimisation potential amounts up to 30% accuracy improvement compared to nonoptimised gauge distributions. Beside this, a correlation between independent reach parameters and dependent infiltration rates could be identified, which is not dominated by the groundwater head.

  19. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  20. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  1. Measuring highway efficiency : A DEA approach and the Malquist index

    NARCIS (Netherlands)

    Sarmento, Joaquim Miranda; Renneboog, Luc; Verga-Matos, Pedro

    A growing concern exists regarding the efficiency of public resources spent in transport infrastructures. In this paper, we measure the efficiency of seven highway projects in Portugal over the past decade by means of a data envelopment analysis and the Malmquist productivity and efficiency indices.

  2. Energy literacy, awareness, and conservation behavior of residential households

    International Nuclear Information System (INIS)

    Brounen, Dirk; Kok, Nils; Quigley, John M.

    2013-01-01

    The residential sector accounts for one-fifth of global energy consumption, resulting from the requirements to heat, cool, and light residential dwellings. It is therefore not surprising that energy efficiency in the residential market has gained importance in recent years. In this paper, we examine awareness, literacy and behavior of households with respect to their residential energy expenditures. Using a detailed survey of 1721 Dutch households, we measure the extent to which consumers are aware of their energy consumption and whether they have taken measures to reduce their energy costs. Our results show that “energy literacy” and awareness among respondents is low: just 56% of the respondents are aware of their monthly charges for energy consumption, and 40% do not appropriately evaluate investment decisions in energy efficient equipment. We document that demographics and consumer attitudes towards energy conservation, but not energy literacy and awareness, have direct effects on behavior regarding heating and cooling of the home. The impact of a moderating factor, measured by thermostat settings, ultimately results in strong variation in the energy consumption of private consumers. - Highlights: • We use a detailed survey of 1,721 Dutch households to measure awareness and conservation behavior in energy consumption. • Energy literacy and awareness among residential households is low. • 40 percent of the sample does not appropriately evaluate investment decisions in energy efficient equipment • Demographics and consumer attitudes affect behavior regarding heating and cooling of a home

  3. DEA Window Analysis for Measuring Port Efficiencies in Serbia

    Directory of Open Access Journals (Sweden)

    Danijela Pjevčević

    2012-01-01

    Full Text Available The aim of the paper is to apply Data Envelopment Analysis (DEA method in measuring and analyzing the efficiencies of ports on the river Danube. DEA window analysis is used to determine the efficiency of ports and to observe the possibility of changes in the port efficiency over time. A study is conducted to evaluate the efficiencies of ports on the territory of Serbia in order to identify the sources of inefficiencies and formulate proposals for improving the services of those ports and their operations through a four-year window analysis with port efficiency trends and average efficiencies. The progress is made in the measurement of port efficiency in relation to port productive activities - total area of warehouses, quay length, number of cranes and port throughput, for the Serbian river ports. Keywords: river ports, total area of warehouses, quay length, number of cranes, port throughput, port efficiency, DEA window analysis

  4. Measurement of photomultiplier effective quantum efficiency

    International Nuclear Information System (INIS)

    Arshad, S.; Gowers, C.; Nielsen, P.

    1998-07-01

    The JET divertor LIDAR system, is being modified to perform measurements of plasma edge electron temperature and density in the new gas-box divertor configuration. The change involves raising the line of sight from the divertor region so that the laser beam passes through the plasma edge reaching a depth of ∼ 5 cm inside the boundary. Changes are also being made to the detection system. This currently employs a grating, spectrometer and a streak camera. The new system will contain a 4-channel filter spectrometer with microchannel plate (MCP) photomuItipliers

  5. Uncertainties for pressure-time efficiency measurements

    OpenAIRE

    Ramdal, Jørgen; Jonsson, Pontus; Dahlhaug, Ole Gunnar; Nielsen, Torbjørn; Cervantes, Michel

    2010-01-01

     In connection with the pressure-time project at the Norwegian University of Science and Technology and Luleå University of Technology, a number of tests with the pressure-time method have been performed at the Waterpower Laboratory in Trondheim, Norway. The aim is to lower the uncertainty and improve usability of the method. Also a field test at the Anundsjoe power plant in Sweden has been performed. The pressure-time measurement is affected by random uncertainty. To minimize the effect of t...

  6. Efficiency measurement of cashew nut marketing in Enugu State ...

    African Journals Online (AJOL)

    Efficiency measurement of cashew nut marketing in Enugu State, Nigeria. ... were the multiple regression analysis to measure the profit function of cashew nut marketing inputs, Marketing margin, Lorenz curve, ... AJOL African Journals Online.

  7. Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.; Ludwig, P.; Brand, L.

    2013-04-01

    This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.

  8. Implications of energy efficiency measures in wheat production

    DEFF Research Database (Denmark)

    Meyer-Aurich, Andreas; Ziegler, T.; Scholz, L.

    The economic and environmental effect of energy saving measures were analyzed for a typical wheat production system in Germany. The introduction of precision farming, reduced nitrogen fertilization and improved crop drying technologies proved to be efficient measures for enhancing energy efficiency...

  9. Residential Energy-Efficiency Equipment Shown to be a Good Investment for U.S. Navy (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2014-04-01

    A two-year project between the National Renewable Energy Laboratory (NREL) and the U.S. Navy's Naval Facilities Engineering Command (NAVFAC) to demonstrate energy efficiency technologies at bases in Hawaii and Guam resulted in the identification of several promising options for reducing energy use and costs, including whole-house energy efficiency retrofits.

  10. SIA model for buildings: energy-efficiency path for commercial and residential buildings. Preliminary study on the Swiss model for buildings - Basics for the revision of the 'SIA energy-efficiency path' - Final report; Gebaeudeparkmodell 'SIA Effizienzpfad Energie', Dienstleistungs- und Wohngebaeude. Vorstudie zum Gebaeudeparkmodell Schweiz - Grundlagen zur Ueberarbeitung des SIA Effizienzpfades Energie - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Heeren, N.; Gabathuler, M.; Wallbaum, H. [Institut fuer Bauplanung und Baubetrieb, Eidgenoessische Technische Hochschule Zuerich (ETHZ), Zuerich (Switzerland); Jakob, M.; Martius, M.; Gross, N. [TEP Energy GmbH, Technology Economics Policy - Research and Advice, Zuerich (Switzerland)

    2009-10-15

    assumptions the goals of the 2000-Watt-Society are not fully met: the relative reduction goals of the per capita total primary energy use (-44%), of the non-renewable primary energy use (-66%) and of the greenhouse gas (GHG) emissions (-77%) are exceeded by 5 to 7 percentage points. Primary energy use per capita is reduced by 36% in the case of the residential buildings and by 39% in the case of office and school buildings. A reduction of 61% is achieved regarding non-renewable primary use and a reduction of 70% in the case of greenhouse gas emissions. Moreover there is evidence the overall target (of all sectors) is also missed. Indeed, in the efficiency scenario, the GHG-emissions of the residential sector alone already account for 40% of the target value of 2 t CO{sub 2}-eq./cap. Further investigations are needed to verify whether this share is too large for the residential sector and whether the overall target could be reached by reductions in the other sectors. Note finally that there is still some leeway also in the case of the efficiency scenario. Although the goal is (slightly) missed it cannot be concluded that the specific target values of the 2000-Watt-Society should be revised. Conversely it is recommended that a target-oriented scenario should be drafted in order to reveal pre-conditions and to derive necessary policy measures. (authors)

  11. Measuring the Externality Effects of Commercial Land Use on Residential Land Value: A Case Study of Seoul

    Directory of Open Access Journals (Sweden)

    Hee Jin Yang

    2016-04-01

    Full Text Available Two contrasting theories purport to explain the effects of neighborhood non-residential use on residential property values. In traditional zoning theory, separating land from commercial land use is considered to protect residential environments from negative externalities such as noise, litter, and congestion. By contrast, contemporary planning principles including Smart Growth emphasize positive impacts of mixed land use on residential environment, which lead to more walkable and sustainable communities. This study attempts to empirically investigate how positive and negative externalities of commercial land use, referred to as “proximity effects” and “disamenity effects” respectively, affect residential land values. Using data gathered in Seoul, we pay attention to two particular aspects of commercial land use: spatial concentration and neighborhood scale. Spatial concentration is determined by the number of commercial employees present in the buffer zone around an individual residential parcel. We model four geographically distinct neighborhood scales as we compare spatial concentrations in and across commercial zones. Quadratic regression analyses of our data show the trade-off relationship that a higher spatial concentration of commercial land use in a neighborhood initially results in increased residential land values, but drops off beyond a threshold level by excessive noise or crowding.

  12. Impacts of residential heating intervention measures on air quality and progress towards targets in Christchurch and Timaru, New Zealand

    Science.gov (United States)

    Scott, Angelique J.; Scarrott, Carl

    2011-06-01

    Elevated wintertime particulate concentrations in the New Zealand cities of Christchurch and Timaru are mostly attributed to the burning of wood and coal for residential heating. A carrot-and-stick approach was adopted for managing air quality in Christchurch, where strict intervention measures were introduced together with a residential heater replacement programme to encourage householders to change to cleaner forms of heating. A similar approach was only recently implemented for Timaru. This paper presents the results of a partial accountability analysis, where the impact of these measures on the target source, PM 10 emissions, and PM 10 concentrations are quantified. A statistical model was developed to estimate trends in the concentrations, which were tested for significance after accounting for meteorological effects, and to estimate the probability of meeting air quality targets. Results for Christchurch and Timaru are compared to illustrate the impacts of differing levels of intervention on air quality. In Christchurch, approximately 34,000 (76%) open fires and old solid fuel burners were replaced with cleaner heating technology from 2002 to 2009, and total open fires and solid fuel burner numbers decreased by 45%. Over the same time period, estimated PM 10 emissions reduced by 71% and PM 10 concentrations by 52% (maxima), 36% (winter mean), 26% (winter median) and 41% (meteorology-adjusted winter means). In Timaru, just 3000 (50%) open fires and old solid fuel burners were replaced from 2001 to 2008, with total open fire and solid fuel burner numbers reduced by 24%. PM 10 emissions declined by 32%, with low reductions in the PM 10 concentrations (maxima decreased by 7%, winter means by 11% and winter medians by 3%). These findings, supported by the results of the meteorology corrected trend analysis for Christchurch, strongly indicate that the combination of stringent intervention measures and financial incentives has led to substantial air quality

  13. Summary of Needs and Opportunities from the 2011 Residential Energy Efficiency Stakeholders Meeting: Atlanta, Georgia -- March 16-18, 2011

    Energy Technology Data Exchange (ETDEWEB)

    2011-05-01

    This summary report outlines needs and issues for increasing energy efficiency of new and existing U.S homes, as identified at the U.S Department of Energy Building America program Spring 2011 stakeholder meeting in Atlanta, Georgia.

  14. Measurements of Capture Efficiency of Range Hoods in Homes

    DEFF Research Database (Denmark)

    Simone, Angela; Sherman, Max H.; Walker, Iain S.

    2015-01-01

    mapped the pollution distribution in the room, and showed that the pollutants escape more at the sides of the cooktop. These preliminary results suggest that more measurements should be conducted investigating the capture efficiency at different pollutant source temperature, size and location...... want a range hood to use little energy and have high capture efficiency to minimize the required air flow to capture the cooking pollutants. Currently there are no standards for rating range hoods for capture efficiency In this study, measurements of range hood capture efficiency were made a tight...... kitchen-room built in a laboratory chamber, and a methodology for standardizing measurement of capture efficiency was developed. The results for a wall mounted range hood, showed that up to half of the cooking pollutants were not captured at a flow rate of 230 m3/h. A more detailed set of measurements...

  15. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source......, but such studies are very expensive if fair representation of both spatial and temporal variations should be obtained. In addition, onsite studies may affect the waste generation in the residence because of the increased focus on the issue. Residential waste is defined in different ways in different countries...

  16. Measuring the performance of electronic health records: a case study in residential aged care in Australia.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu; Yu, Hui; Lei, Jianbo

    2013-01-01

    Measuring the performance of electronic health records (EHR) is an important, yet un-resolved challenge. Various measurements have addressed different aspects of EHR success, yet a holistic, comprehensive measurement tool needs to be developed to capture the potential EHR success variables completely. A self-administered questionnaire survey instrument was developed based on the theoretical framework of the DeLone and McLean Information Systems Success Model. It measures nigh variables of EHR success: system quality, information quality, service quality, training, self efficacy, intention to use, use, user satisfaction and net benefits. The instrument was used to measure the performance of aged care EHR systems in three aged care organizations. The results suggest that the instrument was reliable.

  17. A Measure of the Parent-Team Alliance in Youth Residential Psychiatry: The Revised Short Working Alliance Inventory

    NARCIS (Netherlands)

    Lamers, A.; Delsing, M.J.M.H.; Van Widenfelt, B.M.; Vermeiren, R.R.J.M.

    2015-01-01

    Background: The therapeutic alliance between multidisciplinary teams and parents within youth (semi) residential psychiatry is essential for the treatment process and forms a promising process variable for Routine Outcome Monitoring (ROM). No short evaluative instrument, however, is currently

  18. Measuring energy efficiency in economics: Shadow value approach

    Science.gov (United States)

    Khademvatani, Asgar

    For decades, academic scholars and policy makers have commonly applied a simple average measure, energy intensity, for studying energy efficiency. In contrast, we introduce a distinctive marginal measure called energy shadow value (SV) for modeling energy efficiency drawn on economic theory. This thesis demonstrates energy SV advantages, conceptually and empirically, over the average measure recognizing marginal technical energy efficiency and unveiling allocative energy efficiency (energy SV to energy price). Using a dual profit function, the study illustrates how treating energy as quasi-fixed factor called quasi-fixed approach offers modeling advantages and is appropriate in developing an explicit model for energy efficiency. We address fallacies and misleading results using average measure and demonstrate energy SV advantage in inter- and intra-country energy efficiency comparison. Energy efficiency dynamics and determination of efficient allocation of energy use are shown through factors impacting energy SV: capital, technology, and environmental obligations. To validate the energy SV, we applied a dual restricted cost model using KLEM dataset for the 35 US sectors stretching from 1958 to 2000 and selected a sample of the four sectors. Following the empirical results, predicted wedges between energy price and the SV growth indicate a misallocation of energy use in stone, clay and glass (SCG) and communications (Com) sectors with more evidence in the SCG compared to the Com sector, showing overshoot in energy use relative to optimal paths and cost increases from sub-optimal energy use. The results show that energy productivity is a measure of technical efficiency and is void of information on the economic efficiency of energy use. Decomposing energy SV reveals that energy, capital and technology played key roles in energy SV increases helping to consider and analyze policy implications of energy efficiency improvement. Applying the marginal measure, we also

  19. Measuring sustainability by Energy Efficiency Analysis for Korean Power Companies: A Sequential Slacks-Based Efficiency Measure

    Directory of Open Access Journals (Sweden)

    Ning Zhang

    2014-03-01

    Full Text Available Improving energy efficiency has been widely regarded as one of the most cost-effective ways to improve sustainability and mitigate climate change. This paper presents a sequential slack-based efficiency measure (SSBM application to model total-factor energy efficiency with undesirable outputs. This approach simultaneously takes into account the sequential environmental technology, total input slacks, and undesirable outputs for energy efficiency analysis. We conduct an empirical analysis of energy efficiency incorporating greenhouse gas emissions of Korean power companies during 2007–2011. The results indicate that most of the power companies are not performing at high energy efficiency. Sequential technology has a significant effect on the energy efficiency measurements. Some policy suggestions based on the empirical results are also presented.

  20. Air pollution from residential wood combustion in a Danish village. Measuring campaign and analysis of results

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, P.; Roerdam Olesen, H.; Bossi, R.; Stubkjaer, J.

    2010-05-15

    A campaign took place in the winter 2006/2007 comprising measurements of many air pollution components at two sites: a wood smoke exposed site within the village Slagslunde, and a background site 500 m outside of the village. The report describes the campaign and its results. A central result is a so-called 'wood smoke source profile', which relates several measures of wood smoke pollution to each other. This is based on a 'cleaned' data set, for which the effect of other sources than wood smoke was small. The wood smoke profile links the measures PM2.5, particle volume, soot, monosaccharide anhydrides (levoglucosan and mannosan) and different PAHs to each other. Particle number N does not have a close link to the other measures. (author)

  1. Air pollution from residential wood combustion in a Danish village. Measuring campaign and analysis of results

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, P; Roerdam Olesen, H; Bossi, R; Stubkjaer, J

    2010-05-15

    A campaign took place in the winter 2006/2007 comprising measurements of many air pollution components at two sites: a wood smoke exposed site within the village Slagslunde, and a background site 500 m outside of the village. The report describes the campaign and its results. A central result is a so-called 'wood smoke source profile', which relates several measures of wood smoke pollution to each other. This is based on a 'cleaned' data set, for which the effect of other sources than wood smoke was small. The wood smoke profile links the measures PM2.5, particle volume, soot, monosaccharide anhydrides (levoglucosan and mannosan) and different PAHs to each other. Particle number N does not have a close link to the other measures. (author)

  2. SAVE - energy efficiency in Germany 1990-2000. Report based on the ODYSSEE data base on energy efficiency indicators and the MURE data base on energy efficiency policy measures with the support from SAVE. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Eichhammer, W.; Schlomann, B.

    2002-03-01

    This reports presents an analysis of energy efficiency trends in Germany on the basis of energy efficiency indicators extracted from the ODYSSEE data base, maintained and updated in the framework of the SAVE programme. This analysis focuses on the period 1990-2000. The year 1990 could however not be considered for all indicators, because most of the economic and some energy consumption data for Germany are only available since 1991. The analysis also examines the policies and measures implemented in the field of energy efficiency, with a focus on the latest years until February 2002. All these measures are extracted from the MURE data base also updated within the SAVE programme. The report starts with a review on data collection and the recent trends in the general context of energy efficiency, i. e. economic and energy consumption development, energy and environmental policy and energy price trends (Chapter 2). Afterwards, the energy efficiency trends are described both at the level of the whole economy and at sectoral level (Chapter 3). In Chapter 4 the development in one sector - transport - is described more detailed. For the other sectors (industry, residential, tertiary) Annex 2 presents a selection of commented graphs that show the trends for the main indicators. An overview of the most important measures in the field of energy efficiency policy in the end-use sectors in Germany is given in Annex 1. A more detailed description of the most recent measures is presented in Annex 3. (orig.)

  3. Measuring energy efficiency: Is energy intensity a good evidence base?

    International Nuclear Information System (INIS)

    Proskuryakova, L.; Kovalev, A.

    2015-01-01

    Highlights: • Energy intensity measure reflects consumption, not energy efficiency. • Thermodynamic indicators should describe energy efficiency at all levels. • These indicators should have no reference to economic or financial parameters. • A set of energy efficiency indicators should satisfy several basic principles. • There are trade-offs between energy efficiency, power and costs. - Abstract: There is a widespread assumption in energy statistics and econometrics that energy intensity and energy efficiency are equivalent measures of energy performance of economies. The paper points to the discrepancy between the engineering concept of energy efficiency and the energy intensity as it is understood in macroeconomic statistics. This double discrepancy concerns definitions (while engineering concept of energy efficiency is based on the thermodynamic definition, energy intensity includes economic measures) and use. With regard to the latter, the authors conclude that energy intensity can only provide indirect and delayed evidence of technological and engineering energy efficiency of energy conversion processes, which entails shortcomings for management and policymaking. Therefore, we suggest to stop considering subsectoral, sectoral and other levels of energy intensities as aggregates of lower-level energy efficiency. It is suggested that the insufficiency of energy intensity indicators can be compensated with the introduction of thermodynamic indicators describing energy efficiency at the physical, technological, enterprise, sub-sector, sectoral and national levels without references to any economic or financial parameters. Structured statistical data on thermodynamic efficiency is offered as a better option for identifying break-through technologies and technological bottle-necks that constrain efficiency advancements. It is also suggested that macro-level thermodynamic indicators should be based on the thermodynamic first law efficiency and the energy

  4. Catalogue of Energy Efficiency Measures for France: descriptive fact sheets

    International Nuclear Information System (INIS)

    2012-06-01

    ADEME wished to learn about existing effective energy efficiency measures implemented outside of France, whether cross-sectoral or targeted at a specific sector (industry, transport, buildings or agriculture). The objective of this survey was to determine whether any of these measures could be applied in France, with the goal of holding down the growth of energy consumption. This survey has led to the writing of a catalog of 53 two-page fact sheets describing the measures identified as interesting for France. These measures were analysed via classic criteria of evaluation such as cost-efficiency or impact, allowing to highlight the most successful measures for the French territory

  5. Analysis and proposal of implementation effects of heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period

    International Nuclear Information System (INIS)

    Bao Lingling; Zhao Jing; Zhu Neng

    2012-01-01

    In China, northern heating region contains approximately 6.5 billion m 2 residential building areas accounting for 15% of the total residential living areas of urban and rural. About 70% of the urban residential buildings in north China are high energy consumption buildings. The task of heat metering and energy efficiency retrofit of 0.15 billion m 2 existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period was proposed by the Ministry of Housing and Urban–Rural Development (MOHURD) in 2007 and completed in 2010. This paper introduced both central and local governments' efforts on organization, implementation and finance, etc. Then several retrofitting effects involving improving the people's livelihood, mobilizing the enthusiasm of residents for the retrofit and driving the development of relevant industries were presented. Finally, on the basis of analyzing the issues encountered in the progress of the retrofit in the past 4 years, the paper gave some policy proposals on organization system, financing models, reward mechanism, and heating system reformation to help to promote the energy efficiency retrofit in “the 12th Five-Year Plan” period. - Highlights: ► Specific approaches of heat metering and energy efficiency retrofit (HMEER) at central and local level are introduced. ► Main HMEER effects are presented. ► Analyzing several issues encountered in the progress of the HMEER. ► Corresponding proposals are provided.

  6. Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.

  7. Measurement Properties of the Motivation for Youth Treatment Scale with a Residential Group Home Population

    Science.gov (United States)

    Lambert, Matthew C.; Hurley, Kristin Duppong; Tomlinson, M. Michele Athay; Stevens, Amy L.

    2013-01-01

    Background: A client's motivation to receive services is significantly related to seeking services, remaining in services, and improved outcomes. The Motivation for Youth Treatment Scale (MYTS) is one of the few brief measures used to assess motivation for mental health treatment. Objective: To investigate if the psychometric properties of the…

  8. Measurement of Detector Efficiency for the CZT Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kang Hwa; Kon, Kang Seo; Kim, Jeongin [KHNP, Radiation Health Research Institute, Seoul (Korea, Republic of)

    2014-05-15

    Evaluation method of using CZT have been being attempted in various places such as AEP(American Electronic Power) etc since EDF(Electricite de France) had apply to the project named 'Source Term Reduction'. CZT can measure source terms on various places in nuclear power plants because it is available at room temperature unless a seperate device and portability is good. Consequently, CZT show good result from analysis of source terms in nuclear power plants. This study found out efficiency of CZT detector that is now researched in CZT Monitoring System for measure source terms on RCS system of domestic old and new nuclear power plants and verified measured efficiency values by comparing to reference efficiency we already know. This study was carried out for finding out detector's efficiency depending on necessary energy in order to save quantitative radioactivity value of source terms. Eventually, this study is to develope CZT Monitoring System measuring CRUD in domestic PWRs primary system or piping system by carrying out in-vivo. Considering error ratio ±20% on radioactivity value of CRM used in measuring and verifying efficiency, measurement of detector Efficiency for the CZT Monitoring System is good. But more various tests is needed than now for an accurate measurement.

  9. The Measurement and Determinants of Economic Efficiency of ...

    African Journals Online (AJOL)

    The Measurement and Determinants of Economic Efficiency of Microfinance Institutions ... players in socio-economic development especially in developing countries. ... savings products to improve on portfolio quality and ensure sustainability; ...

  10. Measurement of energy efficiency based on economic foundations

    International Nuclear Information System (INIS)

    Filippini, Massimo; Hunt, Lester C.

    2015-01-01

    Energy efficiency policy is seen as a very important activity by almost all policy makers. In practical energy policy analysis, the typical indicator used as a proxy for energy efficiency is energy intensity. However, this simple indicator is not necessarily an accurate measure given changes in energy intensity are a function of changes in several factors as well as ‘true’ energy efficiency; hence, it is difficult to make conclusions for energy policy based upon simple energy intensity measures. Related to this, some published academic papers over the last few years have attempted to use empirical methods to measure the efficient use of energy based on the economic theory of production. However, these studies do not generally provide a systematic discussion of the theoretical basis nor the possible parametric empirical approaches that are available for estimating the level of energy efficiency. The objective of this paper, therefore, is to sketch out and explain from an economic perspective the theoretical framework as well as the empirical methods for measuring the level of energy efficiency. Additionally, in the second part of the paper, some of the empirical studies that have attempted to measure energy efficiency using such an economics approach are summarized and discussed.

  11. Measuring energy efficiency in the United States` economy: A beginning

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    Energy efficiency is a vital component of the Nation`s energy strategy. One of the Department of Energy`s missions are to promote energy efficiency to help the Nation manage its energy resources. The ability to define and measure energy efficiency is essential to this objective. In the absence of consistent defensible measures, energy efficiency is a vague, subjective concept that engenders directionless speculation and confusion rather than insightful analysis. The task of defining and measuring energy efficiency and creating statistical measures as descriptors is a daunting one. This publication is not a final product, but is EIA`s first attempt to define and measure energy efficiency in a systematic and robust manner for each of the sectors and the United States economy as a whole. In this process, EIA has relied on discussions, customer reviews, in-house reviews, and seminars that have focused on energy efficiency in each of the sectors. EIA solicits the continued participation of its customers in further refining this work.

  12. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  13. Measurements of radon in residential buildings in Maryland and Pennsylvania, U.S.A

    International Nuclear Information System (INIS)

    George, A.C.; Duncan, M.; Franklin, H.

    1984-01-01

    Radon concentrations were measured in six all-electric and 31 randomly selected homes in Pennslyvania, and 41 homes in Maryland. The measurements were made in the basements and living areas of each home using integrating passive activated carbon detectors for an exposure period of about 3 days. The average concentration varied substantially among the homes and correlated well with the age of the home, the degree of insulation, and ventilation. On average, concentrations in the living areas were lower than those in the basements. Radon levels in the living areas of a substantial number of homes (39% in Pennslyvania, excluding the six all-electric homes, and 51% in Maryland) were greater than or equal to 3 pCi.1 -1 , resulting in a substantial annual absorbed dose to the bronchial epithelial cells of the occupants of the homes. (author)

  14. Children's residential exposure to chlorpyrifos: Application of CPPAES field measurements of chlorpyrifos and TCPy within MENTOR/SHEDS-Pesticides model

    International Nuclear Information System (INIS)

    Hore, Paromita; Zartarian, Valerie; Xue Jianping; Ozkaynak, Haluk; Wang, S.-W.; Yang, Y.-C.; Chu, P.-Ling; Sheldon, Linda; Robson, Mark; Needham, Larry; Barr, Dana; Freeman, Natalie; Georgopoulos, Panos; Lioy, Paul J.

    2006-01-01

    The comprehensive individual field-measurements on non-dietary exposure collected in the Children's-Post-Pesticide-Application-Exposure-Study (CPPAES) were used within MENTOR/SHEDS-Pesticides, a physically based stochastic human exposure and dose model. In this application, however, the model was run deterministically. The MENTOR/SHEDS-Pesticides employed the CPPAES as input variables to simulate the exposure and the dose profiles for seven children over a 2-week post-application period following a routine residential and professional indoor crack-and-crevice chlorpyrifos application. The input variables were obtained from a personal activity diary, microenvironmental measurements and personal biomonitoring data obtained from CPPAES samples collected from the individual children and in their homes. Simulation results were compared with CPPAES field measured values obtained from the children's homes to assess the utility of the different microenvironmental data collected in CPPAES, i.e. indicator toys and wipe samplers to estimate aggregate exposures that can be result from one or more exposure pathways and routes. The final analyses of the database involved comparisons of the actual data obtained from the individual biomarker samples of a urinary metabolite of chlorpyrifos (TCPy) and the values predicted by MENTOR/SHEDS-Pesticides using the CPPAES-derived variables. Because duplicate diet samples were not part of the CPPAES study design, SHEDs-Pesticides simulated dose profiles did not account for the dietary route. The research provided more confidence in the types of data that can be used in the inhalation and dermal contact modules of MENTOR/SHEDS-Pesticides to predict the pesticide dose received by a child. It was determined that we still need additional understanding about: (1) the types of activities and durations of activities that result in non-dietary ingestion of pesticides and (2) the influence of dietary exposures on the levels of TCPy found in the

  15. Detector characterization for efficiency calibration in different measurement geometries

    International Nuclear Information System (INIS)

    Toma, M.; Dinescu, L.; Sima, O.

    2005-01-01

    In order to perform an accurate efficiency calibration for different measurement geometries a good knowledge of the detector characteristics is required. The Monte Carlo simulation program GESPECOR is applied. The detector characterization required for Monte Carlo simulation is achieved using the efficiency values obtained from measuring a point source. The point source was measured in two significant geometries: the source placed in a vertical plane containing the vertical symmetry axis of the detector and in a horizontal plane containing the centre of the active volume of the detector. The measurements were made using gamma spectrometry technique. (authors)

  16. Measurement of the track reconstruction efficiency at LHCb

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; van den Brand, Johannes; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gavrilov, Gennadii; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Giani', Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Manca, Giulia; Mancinelli, Giampiero; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Moggi, Niccolò; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Roa Romero, Diego; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruffini, Fabrizio; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wu, Suzhi; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2015-02-12

    The determination of track reconstruction efficiencies at LHCb using $J/\\psi\\rightarrow\\mu^{+}\\mu^{-}$ decays is presented. Efficiencies above $95\\%$ are found for the data taking periods in 2010, 2011, and 2012. The ratio of the track reconstruction efficiency of muons in data and simulation is compatible with unity and measured with an uncertainty of $0.8\\,\\%$ for data taking in 2010, and at a precision of $0.4\\,\\%$ for data taking in 2011 and 2012. For hadrons an additional $1.4\\,\\%$ uncertainty due to material interactions is assumed. This result is crucial for accurate cross section and branching fraction measurements in LHCb.

  17. Measurement of the track reconstruction efficiency at LHCb

    International Nuclear Information System (INIS)

    Collaboration, The LHCb

    2015-01-01

    The determination of track reconstruction efficiencies at LHCb using J/ψ→μ + μ - decays is presented. Efficiencies above 95% are found for the data taking periods in 2010, 2011, and 2012. The ratio of the track reconstruction efficiency of muons in data and simulation is compatible with unity and measured with an uncertainty of 0.8 % for data taking in 2010, and at a precision of 0.4 % for data taking in 2011 and 2012. For hadrons an additional 1.4 % uncertainty due to material interactions is assumed. This result is crucial for accurate cross section and branching fraction measurements in LHCb

  18. Applying DEA sensitivity analysis to efficiency measurement of Vietnamese universities

    Directory of Open Access Journals (Sweden)

    Thi Thanh Huyen Nguyen

    2015-11-01

    Full Text Available The primary purpose of this study is to measure the technical efficiency of 30 doctorate-granting universities, the universities or the higher education institutes with PhD training programs, in Vietnam, applying the sensitivity analysis of data envelopment analysis (DEA. The study uses eight sets of input-output specifications using the replacement as well as aggregation/disaggregation of variables. The measurement results allow us to examine the sensitivity of the efficiency of these universities with the sets of variables. The findings also show the impact of variables on their efficiency and its “sustainability”.

  19. Implementation and rejection of industrial steam system energy efficiency measures

    International Nuclear Information System (INIS)

    Therkelsen, Peter; McKane, Aimee

    2013-01-01

    Steam systems consume approximately one third of energy applied at US industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of 5 years through the Energy Savings Assessment (ESA) program administered by the US Department of Energy (US DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well. - Highlights: ► We examine uptake/rejection of industrial steam system energy efficiency measures. ► We examine metrics that correspond to uptake/rejection of recommended measures. ► We examine barriers hindering steam system energy efficiency measure implementation. ► Uptake/rejection of steam measures is linked to potential cost metrics. ► Increased uptake of measures and uptake of more costly measures increases with time

  20. Measurement system for diffraction efficiency of convex gratings

    Science.gov (United States)

    Liu, Peng; Chen, Xin-hua; Zhou, Jian-kang; Zhao, Zhi-cheng; Liu, Quan; Luo, Chao; Wang, Xiao-feng; Tang, Min-xue; Shen, Wei-min

    2017-08-01

    A measurement system for diffraction efficiency of convex gratings is designed. The measurement system mainly includes four components as a light source, a front system, a dispersing system that contains a convex grating, and a detector. Based on the definition and measuring principle of diffraction efficiency, the optical scheme of the measurement system is analyzed and the design result is given. Then, in order to validate the feasibility of the designed system, the measurement system is set up and the diffraction efficiency of a convex grating with the aperture of 35 mm, the curvature-radius of 72mm, the blazed angle of 6.4°, the grating period of 2.5μm and the working waveband of 400nm-900nm is tested. Based on GUM (Guide to the Expression of Uncertainty in Measurement), the uncertainties in the measuring results are evaluated. The measured diffraction efficiency data are compared to the theoretical ones, which are calculated based on the grating groove parameters got by an atomic force microscope and Rigorous Couple Wave Analysis, and the reliability of the measurement system is illustrated. Finally, the measurement performance of the system is analyzed and tested. The results show that, the testing accuracy, the testing stability and the testing repeatability are 2.5%, 0.085% and 3.5% , respectively.

  1. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  2. Measure Guideline. Steam System Balancing and Tuning for Multifamily Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jayne [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Ludwig, Peter [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Brand, Larry [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States)

    2013-04-01

    This guideline provides building owners, professionals involved in multifamily audits, and contractors insights for improving the balance and tuning of steam systems. It provides readers an overview of one-pipe steam heating systems, guidelines for evaluating steam systems, typical costs and savings, and guidelines for ensuring quality installations. It also directs readers to additional resources for details not included here. Measures for balancing a distribution system that are covered include replacing main line vents and upgrading radiator vents. Also included is a discussion on upgrading boiler controls and the importance of tuning the settings on new or existing boiler controls. The guideline focuses on one-pipe steam systems, though many of the assessment methods can be generalized to two-pipe steam systems.

  3. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  4. Methods of modeling TCO residential real estate in the life cycles of buildings as a promising energy efficiency management tool

    Directory of Open Access Journals (Sweden)

    Kulakov Kirill

    2017-01-01

    Full Text Available Building and developing an affordable housing market is a huge challenge for Russia’s national economy. Today, the housing construction industry finds itself in a situation torn by a conflict caused by the simultaneous needs to minimize the housing construction costs in order to make housing more affordable for Russians and to increase the energy efficiency of the housing projects, which is associated with additional costs for developers. To find solutions to this contradictory situation, one needs new theoretical and practical approaches and economic tools. The global economic trend of managing goods and services on the basis of the value of goods and services over the life cycle is also manifested in the construction industry in Russia. The problem of forming a new economic thinking in the housing sector predetermines the perception of the value of housing not only as the price of purchased real estate, but as the equivalent of the total cost of ownership of real estate throughout its life cycle. This approach allows to compensate the initial rise in the cost of construction resulting from the introduction of energy-efficient technologies by savings in the operational phase of the life cycle of the property. In this regard, management of the total cost of real estate ownership based on energy modeling is of high research and practical relevance.

  5. A Framework for Comparative Assessments of Energy Efficiency Policy Measures

    Energy Technology Data Exchange (ETDEWEB)

    Blum, Helcio; Atkinson, Barbara; Lekov, Alex

    2011-05-24

    When policy makers propose new policies, there is a need to assess the costs and benefits of the proposed policy measures, to compare them to existing and alternative policies, and to rank them according to their effectiveness. In the case of equipment energy efficiency regulations, comparing the effects of a range of alternative policy measures requires evaluating their effects on consumers’ budgets, on national energy consumption and economics, and on the environment. Such an approach should be able to represent in a single framework the particularities of each policy measure and provide comparable results. This report presents an integrated methodological framework to assess prospectively the energy, economic, and environmental impacts of energy efficiency policy measures. The framework builds on the premise that the comparative assessment of energy efficiency policy measures should (a) rely on a common set of primary data and parameters, (b) follow a single functional approach to estimate the energy, economic, and emissions savings resulting from each assessed measure, and (c) present results through a set of comparable indicators. This framework elaborates on models that the U.S. Department of Energy (DOE) has used in support of its rulemakings on mandatory energy efficiency standards. In addition to a rigorous analysis of the impacts of mandatory standards, DOE compares the projected results of alternative policy measures to those projected to be achieved by the standards. The framework extends such an approach to provide a broad, generic methodology, with no geographic or sectoral limitations, that is useful for evaluating any type of equipment energy efficiency market intervention. The report concludes with a demonstration of how to use the framework to compare the impacts estimated for twelve policy measures focusing on increasing the energy efficiency of gas furnaces in the United States.

  6. Feed conversion efficiency in aquaculture: do we measure it correctly?

    Science.gov (United States)

    Fry, Jillian P.; Mailloux, Nicholas A.; Love, David C.; Milli, Michael C.; Cao, Ling

    2018-02-01

    Globally, demand for food animal products is rising. At the same time, we face mounting, related pressures including limited natural resources, negative environmental externalities, climate disruption, and population growth. Governments and other stakeholders are seeking strategies to boost food production efficiency and food system resiliency, and aquaculture (farmed seafood) is commonly viewed as having a major role in improving global food security based on longstanding measures of animal production efficiency. The most widely used measurement is called the ‘feed conversion ratio’ (FCR), which is the weight of feed administered over the lifetime of an animal divided by weight gained. By this measure, fed aquaculture and chickens are similarly efficient at converting feed into animal biomass, and both are more efficient compared to pigs and cattle. FCR does not account for differences in feed content, edible portion of an animal, or nutritional quality of the final product. Given these limitations, we searched the literature for alternative efficiency measures and identified ‘nutrient retention’, which can be used to compare protein and calories in feed (inputs) and edible portions of animals (outputs). Protein and calorie retention have not been calculated for most aquaculture species. Focusing on commercial production, we collected data on feed composition, feed conversion ratios, edible portions (i.e. yield), and nutritional content of edible flesh for nine aquatic and three terrestrial farmed animal species. We estimate that 19% of protein and 10% of calories in feed for aquatic species are ultimately made available in the human food supply, with significant variation between species. Comparing all terrestrial and aquatic animals in the study, chickens are most efficient using these measures, followed by Atlantic salmon. Despite lower FCRs in aquaculture, protein and calorie retention for aquaculture production is comparable to livestock production

  7. Measuring Government Expenditure Efficiencies Towards Peace and Human Development

    Directory of Open Access Journals (Sweden)

    Ahmad Danu Prasetyo

    2014-02-01

    Full Text Available In this paper, we investigate the efficiency level of government expenditure in 82 countries towards the human development and peace index of the respective countries by using Data Envelopment Analysis (DEA approach during 2007-2011. We found that only few countries that always being positioned in the efficient frontier during the sample period, namely: Japan, Nigeria, and Norway.  By using Malmquist index approach, we also found that Cyprus has the largest government expenditure efficiency improvement.Keywords: Government Expenditure Efficiencies, Human Development Index, Global Peace Indexdoi:10.12695/ajtm.2013.6.2.3 How to cite this article:Prasetyo, A.D., and Pudjono, A.N.S. (2013. Measuring Government Expenditure Efficiencies Towards Peace and Human Development. The Asian Journal of Technology Management 6 (2: 82-91. Print ISSN: 1978-6956; Online ISSN: 2089-791X. doi:10.12695/ajtm.2013.6.2.3

  8. A combined sustainability index for electricity efficiency measures

    International Nuclear Information System (INIS)

    Goldrath, T.; Ayalon, O.; Shechter, M.

    2015-01-01

    One of the most substantial tools that serve decision makers in their efforts to reduce greenhouse gas emissions includes energy efficiency measures that in most cases benefit from governmental assistance for achieving electricity consumption reduction goals. This paper examines five energy efficiency measures, defining a combined sustainability index. A multi-criteria analysis of five predefined indices was developed (economic, environmental, technology, social and political), providing a combined index for each measure and a tool for identifying the preferred measure within a specific situation, based on its total sustainability score. In this research, a case study was conducted and the preferred measure was found to be municipal street lighting systems, based on its high political and social scores, and its relatively high installation potential. The second choice would be replacement of chillers in the industrial sector, and the least favorable measure is the replacement of water pumps in the water sector. The methodology described brings into account the technological specifications of the measure implemented, and the specific national conditions under which it is implemented. - Highlights: • A MCDA of five indices was developed to define a combined sustainability index. • Criteria defined were environment, technology, economy, social and political. • Five energy efficiency measures were rated, based on their total sustainability score. • Measures were in five main electricity consumption sectors. • The preferred measure found in the case study was municipal street lighting systems.

  9. Aspects of volumetric efficiency measurement for reciprocating engines

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2013-01-01

    Full Text Available The volumetric efficiency significantly influences engine output. Both design and dimensions of an intake and exhaust system have large impact on volumetric efficiency. Experimental equipment for measuring of airflow through the engine, which is placed in the intake system, may affect the results of measurements and distort the real picture of the impact of individual structural factors. This paper deals with the problems of experimental determination of intake airflow using orifice plates and the influence of orifice plate diameter on the results of the measurements. The problems of airflow measurements through a multi-process Otto/Diesel engine were analyzed. An original method for determining volumetric efficiency was developed based on in-cylinder pressure measurement during motored operation, and appropriate calibration of the experimental procedure was performed. Good correlation between the results of application of the original method for determination of volumetric efficiency and the results of theoretical model used in research of influence of the intake pipe length on volumetric efficiency was determined. [Acknowledgments. The paper is the result of the research within the project TR 35041 financed by the Ministry of Science and Technological Development of the Republic of Serbia

  10. Measuring capital market efficiency: Global and local correlations structure

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav; Vošvrda, Miloslav

    2013-01-01

    Roč. 392, č. 1 (2013), s. 184-193 ISSN 0378-4371 R&D Projects: GA ČR(CZ) GBP402/12/G097 Institutional support: RVO:67985556 Keywords : Capital market efficiency * Fractal dimension * Long-range dependence * Short-range dependence Subject RIV: AH - Economics Impact factor: 1.722, year: 2013 http://library.utia.cas.cz/separaty/2012/E/kristoufek-measuring capital market efficiency global and local correlations structure.pdf

  11. Measuring of Second-order Stochastic Dominance Portfolio Efficiency

    Czech Academy of Sciences Publication Activity Database

    Kopa, Miloš

    2010-01-01

    Roč. 46, č. 3 (2010), s. 488-500 ISSN 0023-5954 R&D Projects: GA ČR GAP402/10/1610 Institutional research plan: CEZ:AV0Z10750506 Keywords : stochastic dominance * stability * SSD porfolio efficiency Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.461, year: 2010 http://library.utia.cas.cz/separaty/2010/E/kopa-measuring of second-order stochastic dominance portfolio efficiency.pdf

  12. Compact and efficient blue laser sheet for measurement

    Science.gov (United States)

    Qi, Yan; Wang, Yu; Wu, Bin; Wang, Yanwei; Yan, Boxia

    2017-10-01

    Compact and efficient blue laser sheet has important applications in the field of measurement, with laser diode end pumped Nd:YAG directly and LBO intracavity frequency doubling, a compact and efficient CW 473nm blue laser sheet composed of dual path liner blue laser is realized. At an incident pump power of 12.4W, up to 1.4W output power of the compound blue laser is achieved, the optical-to-optical conversion efficiency is as high as 11.3%.

  13. Catalogue of Energy Efficiency Measures for France - Synthesis report

    International Nuclear Information System (INIS)

    2013-10-01

    ADEME wished to learn about existing effective energy efficiency measures implemented outside of France, whether cross-sectoral or targeted at a specific sector (industry, transport, buildings or agriculture). The objective of this survey was to determine whether any of these measures could be applied in France, with the goal of holding down the growth of energy consumption. This survey has led to the writing of a catalog of 53 two-page fact sheets describing the measures identified as interesting for France. These measures were analysed via classic criteria of evaluation such as cost-efficiency or impact, allowing to highlight the most successful measures for the French territory. ADEME presents you a synthesis of this survey in this document

  14. Sustainable residential districts : the residents' role in project success

    NARCIS (Netherlands)

    Abdalla, G.

    2012-01-01

    Sustainable residential districts have been realized worldwide. These districts are promoted to be efficient in the use of natural materials and sustainable energy resources. Realization of sustainable residential districts can strongly contribute to achieve environmental objectives as imposed by

  15. Implementation and Rejection of Industrial Steam System Energy Efficiency Measures

    Energy Technology Data Exchange (ETDEWEB)

    Therkelesen, Peter [Environmental Energy Technologies Division Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); McKane, Aimee [Environmental Energy Technologies Division Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2013-05-01

    Steam systems consume approximately one third of energy applied at U.S. industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of five years through the Energy Savings Assessment (ESA) program administered by the U.S. Department of Energy (U.S. DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well.

  16. Residential space heating with wood burning stoves. Energy efficiency and indoor climate; Boligopvarmning ved braendefyring. Energieffektivitet og indeklima

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Ole Michael; Afshari, A.; Bergsoee, N.C.; Carvalho, R. [Miljoestyrelsen, Copenhagen (Denmark); Aalborg Univ.. Statens Byggeforskningsinstitut, Aalborg (Denmark))

    2012-11-01

    become even better at releasing heat slowly. With respect to emissions of particles, the study shows that particles are not only a matter of possible health nuisance for the neighbours, but also a matter of health nuisance for the users themselves. The study also shows that the use of wood-burning stoves can easily give rise to emission of particles to the indoor air. The novelty of this study is that measuring has been performed on particles that can neither be seen nor weighed, the so-called ultrafine particles, i.e. particles between 0.01 and 0.1 microns in diameter. In the most glaring cases, billions of ultrafine particles were counted, especially when firing the stove. Measurements showed that ultrafine particles can be released suddenly. The studies also showed that the risk of particle release is increased in airtight houses with mechanical ventilation; probably due to the negative pressure that the ventilation system creates in these houses. (LN)

  17. The effects of window alternatives on energy efficiency and building economy in high-rise residential buildings in moderate to humid climates

    International Nuclear Information System (INIS)

    Yaşar, Yalçın; Kalfa, Sibel Maçka

    2012-01-01

    Highlights: ► We investigated energy and economy efficiency of window alternatives in Trabzon. ► Energy consumptions of eight window alternatives were simulated and discussed. ► Window alternatives’s life cycle costs were calculated and compared. ► We suggested appropriate energy and economy efficient window alternatives. ► The study defines useful guidelines to select appropriate window alternatives. - Abstract: Currently, focused efforts are being made to determine the influence of windows on the energy consumption and economy of high-rise buildings. Certain window designs and appropriate glazing systems reduce building energy consumption for heating and cooling and contribute to building economy. This paper addresses double-glazed window units that are composed of tinted glass; clear reflective glass; low emissivity (low-e) glass; and smart glass (one surface consists of a high-performance, heat-reflective glass, and other surface has a low-emissivity coated). These materials reduce the heating and cooling loads of buildings by providing solar control and heat conservation. The aim of this study was to investigate the effects of these alternative units, rather than readily available double-glazed units, in two types of flats. The flats have the same construction and operating system, but they have different plan types with regard to building energy consumption and building economy as it relates to life cycle cost analysis. For this study, we selected buildings in Trabzon, in Climate Region II of Turkey, due to its moderate-humid climate. F- and C-type high-rise residential blocks, with flats composed of two to three bedrooms, constructed by the Republic of Turkey’s Prime Ministry Housing Development Administration of Turkey (TOKİ) are used as models for the simulation. The flat plans in these blocks are modeled using DesignBuilder v.1.8 energy simulation software. The simulation results show that smart-glazed units and those with low emissivity

  18. Measurements of the Electron Reconstruction and Identification Efficiencies in ATLAS

    CERN Document Server

    Sommer, P; The ATLAS collaboration

    2014-01-01

    Isolated, high-energy electrons constitute a very clean signature at hadron collider experiments. As the final states of many Standard Model processes, as well as physics beyond the Standard Model, analyses at the ATLAS experiment heavily rely on electrons. A precise knowledge of the efficiency to correctly reconstruct and identify these electrons is thus important. In this contribution the measurement of these efficiencies is described. It is performed with a tag-and-probe method using $Z$ and $J/\\psi$ decays to electrons in $20.3\\,\\mathrm{fb}^{-1}$ of $pp$ collisions recorded in 2012 at $\\sqrt{s}=8$ TeV. The combination of the measurements results in identification efficiencies determined with an accuracy of a few per mil for electrons with a transverse energy of $E_{\\mathrm{T}}>30$ GeV.

  19. Measuring Eco-efficiency of Production with Data Envelopment Analysis

    NARCIS (Netherlands)

    Kuosmanen, T.K.; Kortelainen, M.

    2005-01-01

    Aggregation of environmental pressures into a single environmental damage index is a major challenge of eco-efficiency measurement. This article examines how the data envelopment analysis (DEA) method can be adapted for this purpose. DEA accounts for substitution possibilities between different

  20. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  1. Measurement of technical efficiency and its determinants in crop ...

    African Journals Online (AJOL)

    This study was designed to measure technical efficiency and identify its determinants in crop production in Lafia Local government Area of Nasarawa State of Nigeria using a stochastic frontier production model. Double stage random sampling technique was used to select 100 crop farmers from which input-output data ...

  2. Potential of energy efficiency measures in the world steel industry.

    NARCIS (Netherlands)

    Galama, Tjebbe

    2013-01-01

    SUMMARY The world steel industry plays a major role in energy use and Greenhouse Gas (GHG) emissions now and in the future. Implementing energy efficiency measures is among one of the most cost-effective investments that the industry could make in improv

  3. Efficiency Measurement Using a Motor-Dynamo Module

    Science.gov (United States)

    Ng, Pun-hon; Wong, Siu-ling; Mak, Se-yuen

    2009-01-01

    In this article, we describe a simple method which can be used to measure the efficiency of a low power dc motor, a motor-converted dynamo and a coupled motor-dynamo module as a function of the speed of rotation. The result can also be used to verify Faraday's law of electromagnetic induction. (Contains 1 table and 8 figures.)

  4. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  5. Residential greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    The following report examines the technical and economic viability of residential greenhouse additions in Whitehorse, Yukon. The greenhouse was constructed using the south facing wall of an existing residence as a common wall. Total construction costs were $18,000, including labour. Annual fuel demand for the residence has been reduced by about 10 per cent for an annual saving of $425. In addition, produce to the value of $1,000 is grown annually in the greenhouse for domestic consumption and commercial resale. Typically the greenhouse operates for nine months each year. There is a net thermal loss during the months of November, December and January as a result of the large area of glazing. As well as supplementing the heating supply solar greenhouses can provide additional cash crops which can be used to offset the cost of construction. Humidity problems are minimal and can be dealt with by exhausting high humidity air. One system which has been considered for the greenhouse is to use a standard residential heat pump to remove excess moisture and to pump heat into the house. This would have a secondary benefit of excluding the need to circulate greenhouse air through the house. Thus any allergenic reactions to the greenhouse air would be prevented. 8 refs., 3 figs, 2 tabs.

  6. Efficiency of entanglement of distant atoms by projective measurement

    Energy Technology Data Exchange (ETDEWEB)

    Olivares Renteria, Georgina; Zippilli, Stefano; Morigi, Giovanna [Departament de Fisica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Rohde, Felix; Schuck, Carsten; Eschner, Juergen [ICFO - Institut de CIencies Fotoniques, 08860 Castelldefels, Barcelona (Spain)

    2008-07-01

    We compare the efficiency of two schemes for the preparation of entangled states of distant atoms. In these proposals the atoms do not interact and the entanglement is realized by means of the measurement of the scattered field which project the two atoms into the desired state. We quantify the efficiency of the schemes using the fidelity between the state of the system after the detection of a photon and an ideal entangled state of the two atoms. In the first scheme the atoms interact with two optical cavities and the enhanced probability of emission into the cavities allows for high detection efficiency. This scheme is limited by the finite probability of emission of two photons. Thus, even under the assumption of perfect detection efficiency, the fidelity of the scheme never reaches unity. In the second scheme emission of two photons is suppressed by low excitation strength, but the detection efficiency is low since the atoms scatter into free space and only a small fraction of the photons is measured. In this case the fidelity is conditioned on single-photon detection and results to be higher. The comparison is quantitatively evaluated for an ongoing experiment with two distant trapped single Ca+ ions.

  7. Extrapolated HPGe efficiency estimates based on a single calibration measurement

    International Nuclear Information System (INIS)

    Winn, W.G.

    1994-01-01

    Gamma spectroscopists often must analyze samples with geometries for which their detectors are not calibrated. The effort to experimentally recalibrate a detector for a new geometry can be quite time consuming, causing delay in reporting useful results. Such concerns have motivated development of a method for extrapolating HPGe efficiency estimates from an existing single measured efficiency. Overall, the method provides useful preliminary results for analyses that do not require exceptional accuracy, while reliably bracketing the credible range. The estimated efficiency element-of for a uniform sample in a geometry with volume V is extrapolated from the measured element-of 0 of the base sample of volume V 0 . Assuming all samples are centered atop the detector for maximum efficiency, element-of decreases monotonically as V increases about V 0 , and vice versa. Extrapolation of high and low efficiency estimates element-of h and element-of L provides an average estimate of element-of = 1/2 [element-of h + element-of L ] ± 1/2 [element-of h - element-of L ] (general) where an uncertainty D element-of = 1/2 (element-of h - element-of L ] brackets limits for a maximum possible error. The element-of h and element-of L both diverge from element-of 0 as V deviates from V 0 , causing D element-of to increase accordingly. The above concepts guided development of both conservative and refined estimates for element-of

  8. Measurement of the Photoelectron Detection Efficiency of the HPD Anode

    CERN Document Server

    Carson, L; Soler, P

    2009-01-01

    This paper reports on measurements carried out on the Hybrid Photon Detectors (HPDs) of the LHCb RICH detectors. The purpose of these tests is to determine the photoelectron detection efficiency $\\eta$ of the HPD anode. Knowledge of $\\eta$ is required for an accurate simulation of the RICH detectors. It is found that this efficiency is $(93.3\\pm0.7)\\%$ for a 50 ns digital readout window, and $(87.9\\pm1.4)\\%$ for a 25 ns digital readout window. The 25 ns result exceeds the LHCb-RICH requirement of 85\\%, and is in agreement both with direct $\\eta$ measurements using preseries HPDs, and with indirect measurements from testbeams using preseries and production HPDs.

  9. Energy transfer efficiency measurements in a theta-pinch

    International Nuclear Information System (INIS)

    Cavalcanti, G.H.; Luna, F.R.T.; Trigueiros, A.G.

    1993-01-01

    An increase in energy transfer efficiency of the capacitor bank to the plasma was obtained when the electrical system of a theta-pinch was changed so that the ratio of total inductance to coil inductance was switched of 1/6 to 1/2. A further increase about 20% was obtained for 16/1 ratio. The measurements were made through the current discharge decay, and the spectral analysis of the emitted light from theta-pinch shows a correspondent efficiency increase. (author)

  10. Residential Energy Efficiency Potential: Texas

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Texas single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  11. Residential Energy Efficiency Potential: Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Oregon single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  12. Residential Energy Efficiency Potential: Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Pennsylvania single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  13. Residential Energy Efficiency Potential: Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Tennessee single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  14. Residential Energy Efficiency Potential: Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Nevada single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  15. Residential Energy Efficiency Potential: Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Nebraska single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  16. Residential Energy Efficiency Potential: Washington

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-27

    Energy used by Washington single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  17. Residential Energy Efficiency Potential: Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-15

    Energy used by Alabama single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  18. Residential Energy Efficiency Potential: Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Maryland single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  19. Residential Energy Efficiency Potential: Minnesota

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Minnesota single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  20. Residential Energy Efficiency Potential: Florida

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Florida single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  1. Residential Energy Efficiency Potential: Wisconsin

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-27

    Energy used by Wisconsin single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  2. Residential Energy Efficiency Potential: Maine

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Maine single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  3. Residential Energy Efficiency Potential: Georgia

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-17

    Energy used by Georgia single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  4. Residential Energy Efficiency Potential: Missouri

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Missouri single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  5. Residential Energy Efficiency Potential: Utah

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Utah single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  6. Residential Energy Efficiency Potential: Idaho

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Idaho single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  7. Residential Energy Efficiency Potential: Arizona

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Arizona single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  8. Residential Energy Efficiency Potential: Virginia

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-27

    Energy used by Virginia single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  9. Residential Energy Efficiency Potential: Kentucky

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Kentucky single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  10. Residential Energy Efficiency Potential: Kansas

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Kansas single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  11. Residential Energy Efficiency Potential: Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Louisiana single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  12. Residential Energy Efficiency Potential: Iowa

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Iowa single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  13. Residential Energy Efficiency Potential: Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-27

    Energy used by Wyoming single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  14. Residential Energy Efficiency Potential: Illinois

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Illinois single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  15. Residential Energy Efficiency Potential: Delaware

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Delaware single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  16. Residential Energy Efficiency Potential: Arkansas

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Arkansas single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  17. Residential Energy Efficiency Potential: Montana

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Montana single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  18. Residential Energy Efficiency Potential: Mississippi

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Mississippi single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  19. Residential Energy Efficiency Potential: Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Michigan single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  20. Residential Energy Efficiency Potential: Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Colorado single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  1. Residential Energy Efficiency Potential: Connecticut

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by Connecticut single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  2. Residential Energy Efficiency Potential: Indiana

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Indiana single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  3. Residential Energy Efficiency Potential: California

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by California single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  4. Residential Energy Efficiency Potential: Vermont

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-22

    Energy used by Vermont single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  5. Residential Energy Efficiency Potential: Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-21

    Energy used by Massachusetts single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  6. Residential Energy Efficiency Potential: Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Ohio single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  7. Residential Energy Efficiency Potential: Oklahoma

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Oklahoma single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  8. Measurement of cost efficiency in the European banking industry

    Directory of Open Access Journals (Sweden)

    Branka Tuškan

    2016-04-01

    Full Text Available In this paper we analysed and compared efficiency results in the banking industry using two different approaches: financial indicators and the Data Envelopment Analysis (DEA methodology. In the indicator-based approach, we used chosen accounting ratios (Return on Assets - ROA, Return on Equity – ROE and Cost to Income Ratio - CIR and the descriptive statistics methodology to conduct analysis. In the case of DEA, a nonparametric linear programming methodology approach, expenses as input data and income as output data are used for measuring efficiency using the CCR DEA model, BCC DEA model and window analysis DEA technique. The objective of this research is ascertain whether a correlation exists between the results of the different ways of measuring efficiency. In that sense, the main purpose of this research is to draw a more precise conclusion about the efficiency of the banking industry, as tested for the period 2008–2012 on a sample of 28 European banking systems. The main difference in the obtained results is a lag of values of average accounting ratios in comparison to the results of the DEA methodology. Such a finding suggests that the DEA methodology can be useful in detecting early signs of inadequate business strategies, which can lead to the slowdown of business activity or poorer efficiency results. This can be especially important in times of an unstable financial or macroeconomic environment, as it can assist in detecting early signs of a crisis. In general, the results of both approaches suggest that banking systems in post-transition countries have a higher cost efficiency. Such systems continue to be dominantly financed through long-term deposits and are also exposed to a specific risk. They do business in a specific competitive, financial and macroeconomic environment that significantly influences the prices of financial services (i.e. higher margins, and as a consequence, leads to potentially higher banking sector earnings.

  9. Efficiency measurement of the NeuLAND detector

    Energy Technology Data Exchange (ETDEWEB)

    Toernqvist, Hans; Atar, Leyla; Aumann, Thomas; Holl, Matthias; Horvat, Andrea; Kahlbow, Julian; Miki, Kenjiro; Rossi, Dominic; Scheit, Heiko; Schindler, Fabia [Institut fuer Kernphysik, Technische Universitaet Darmstadt, Darmstadt (Germany); Boretzky, Konstanze; Caesar, Christoph; Simon, Haik [GSI Gesellschaft fuer Schwerionenforschung GmbH, Darmstadt (Germany); Gasparic, Igor [Ruder Boskovic Institute, Zagreb (Croatia); Collaboration: R3B-Collaboration

    2016-07-01

    NeuLAND is the next-generation high-energy and high-efficiency neutron detector currently under construction at GSI/FAIR by the R{sup 3}B collaboration. This detector will be used in a wide variety of experiments, ranging from nuclear-structure measurements of neutron-rich species to the investigation of the equation-of-state of asymmetric nuclear matter. The design goals of the full NeuLAND detector are a >95% detection efficiency for single neutrons, a time resolution of σ{sub t} ≤ 150 ps and a position resolution of σ{sub x,y,z} ≤ 1.5 cm, with a detection volume of 250 x 250 x 300 cm{sup 3}. While still under construction, a set of 4 of the 30 planned NeuLAND double-planes were used for a series of experiments at the SAMURAI setup at RIKEN. In particular, the time resolution and one-neutron efficiency were measured using neutrons from the {sup 7}Li(p,n){sup 7}Be reaction. The test setup at RIKEN are described, and the resolution and efficiency results are discussed.

  10. A two-stage DEA approach for environmental efficiency measurement.

    Science.gov (United States)

    Song, Malin; Wang, Shuhong; Liu, Wei

    2014-05-01

    The slacks-based measure (SBM) model based on the constant returns to scale has achieved some good results in addressing the undesirable outputs, such as waste water and water gas, in measuring environmental efficiency. However, the traditional SBM model cannot deal with the scenario in which desirable outputs are constant. Based on the axiomatic theory of productivity, this paper carries out a systematic research on the SBM model considering undesirable outputs, and further expands the SBM model from the perspective of network analysis. The new model can not only perform efficiency evaluation considering undesirable outputs, but also calculate desirable and undesirable outputs separately. The latter advantage successfully solves the "dependence" problem of outputs, that is, we can not increase the desirable outputs without producing any undesirable outputs. The following illustration shows that the efficiency values obtained by two-stage approach are smaller than those obtained by the traditional SBM model. Our approach provides a more profound analysis on how to improve environmental efficiency of the decision making units.

  11. Data on European non-residential buildings.

    Science.gov (United States)

    D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo

    2017-10-01

    This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.

  12. Do energy efficiency measures promote the use of renewable sources?

    International Nuclear Information System (INIS)

    Marques, Antonio C.; Fuinhas, Jose A.

    2011-01-01

    This paper analyses the factors behind the deployment of renewable energy, focusing particularly on the effect of energy efficiency policies and measures. The impact of these factors is appraised within the context of several phases of the use of renewable sources. We therefore apply the quantile regression technique to a set of 21 European Countries in two time spans: from 1990 to 1998, and from 1999 to 2006. We control variables of policy, environment, socioeconomic characteristics, and electricity generation. For the second period, energy efficiency policies and measures concerning renewable sources effectively promote renewables, namely in the take-off phase. We shed light on the lobbying effect of traditional energy industries, showing that it depends both on the period under analysis, and on the kind of traditional energy source.

  13. Profiling Space Heating Behavior in Chilean Social Housing: Towards Personalization of Energy Efficiency Measures

    Directory of Open Access Journals (Sweden)

    Victor Bunster

    2015-06-01

    Full Text Available Global increases in the demand for energy are imposing strong pressures over the environment while compromising the capacity of emerging economies to achieve sustainable development. In this context, implementation of effective strategies to reduce consumption in residential buildings has become a priority concern for policy makers as minor changes at the household scale can result in major energy savings. This study aims to contribute to ongoing research on energy consumer profiling by exploring the forecasting capabilities of discrete socio-economic factors that are accessible through social housing allocation systems. Accordingly, survey data gathered by the Chilean Ministry of Social Development was used identify key characteristics that may predict firewood usage for space heating purposes among potential beneficiaries of the Chilean social housing program. The analyzed data evidences strong correlations between general household characteristics and space heating behavior in certain climatic zones, suggesting that personalized delivery of energy efficiency measures can potentially increase the effectiveness of initiatives aimed towards the reduction of current patterns of consumption.

  14. Measurement of TFTR D-T radiation shielding efficiency

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ascione G.; Elwood, S.

    1994-01-01

    High power D-T fusion reactor designs presently exhibit complex geometric and material density configurations. Simulations of the radiation shielding required for safe operation and full compliance with all regulatory requirements must include sufficient margin to accommodate uncertainties in material properties and distributions, uncertainties in the final configurations, and uncertainties in approximations employing the homogenization of complex geometries. Measurements of radiation shielding efficiency performed in a realistic D-T tokamak environment can provide empirical guidance for simulating safe, efficient, and cost effective shielding systems for future high power fusion reactors. In this work, the authors present the results of initial measurements of the TFTR radiation shielding efficiency during high power D-T operations with record neutron yields. The TFTR design objective is to limit the total dose-equivalent at the nearest PPPL property lines from all radiation pathways to 10 mrem per calendar year. Compliance with this design objective over a calendar year requires measurements in the presence of typical site backgrounds of about 80 mrem per year

  15. Measuring mixing efficiency in experiments of strongly stratified turbulence

    Science.gov (United States)

    Augier, P.; Campagne, A.; Valran, T.; Calpe Linares, M.; Mohanan, A. V.; Micard, D.; Viboud, S.; Segalini, A.; Mordant, N.; Sommeria, J.; Lindborg, E.

    2017-12-01

    Oceanic and atmospheric models need better parameterization of the mixing efficiency. Therefore, we need to measure this quantity for flows representative of geophysical flows, both in terms of types of flows (with vortices and/or waves) and of dynamical regimes. In order to reach sufficiently large Reynolds number for strongly stratified flows, experiments for which salt is used to produce the stratification have to be carried out in a large rotating platform of at least 10-meter diameter.We present new experiments done in summer 2017 to study experimentally strongly stratified turbulence and mixing efficiency in the Coriolis platform. The flow is forced by a slow periodic movement of an array of large vertical or horizontal cylinders. The velocity field is measured by 3D-2C scanned horizontal particles image velocimetry (PIV) and 2D vertical PIV. Six density-temperature probes are used to measure vertical and horizontal profiles and signals at fixed positions.We will show how we rely heavily on open-science methods for this study. Our new results on the mixing efficiency will be presented and discussed in terms of mixing parameterization.

  16. Approximate determination of efficiency for activity measurements of cylindrical samples

    Energy Technology Data Exchange (ETDEWEB)

    Helbig, W [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany); Bothe, M [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    Some calibration samples are necessary with the same geometrical parameters but of different materials, containing known activities A homogeniously distributed. Their densities are measured, their mass absorption coefficients may be unknown. These calibration samples are positioned in the counting geometry, for instance directly on the detector. The efficiency function {epsilon}(E) for each sample is gained by measuring the gamma spectra and evaluating all usable gamma energy peaks. From these {epsilon}(E) the common valid {epsilon}{sub geom}(E) will be deduced. For this purpose the functions {epsilon}{sub mu}(E) for these samples have to be established. (orig.)

  17. Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Cummings, Jamie E. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Vieira, Robin K. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Fairey, III, Phillip W. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Sherwin, John S. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Withers, Jr., Charles [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Hoak, David [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Beal, David [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  18. Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D.; Kono, J.; Vieira, R.; Fairey, P.; Sherwin, J.; Withers, C.; Hoak, D.; Beal, D.

    2014-05-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  19. Measurements of light absorption efficiency in InSb nanowires

    Directory of Open Access Journals (Sweden)

    A. Jurgilaitis

    2014-01-01

    Full Text Available We report on measurements of the light absorption efficiency of InSb nanowires. The absorbed 70 fs light pulse generates carriers, which equilibrate with the lattice via electron-phonon coupling. The increase in lattice temperature is manifested as a strain that can be measured with X-ray diffraction. The diffracted X-ray signal from the excited sample was measured using a streak camera. The amount of absorbed light was deduced by comparing X-ray diffraction measurements with simulations. It was found that 3.0(6% of the radiation incident on the sample was absorbed by the nanowires, which cover 2.5% of the sample.

  20. Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

    Science.gov (United States)

    Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J

    2015-12-01

    Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems. © 2014 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.

  1. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  2. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  3. ICT energy efficiency in higher education. Continuous measurement and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ter Hofte, H. [Novay, Enschede (Netherlands)

    2011-11-15

    Power consumption of information and communications technology (ICT) is rising rapidly worldwide. Reducing (the growth in) energy demand helps to achieve sustainability goals in the area of energy resource depletion, energy security, economy, and ecology. Various governments and industry consortia have set out policies and agreements to reduce the (growth in) demand for energy. In the MJA3 agreements in the Netherlands, various organizations, including all 14 universities and 39 universities of applied sciences pledged to achieve 30% increase in energy efficiency in 2020 compared to 2005. In this report, we argue that using the number of kilowatt-hours of final electricity used for ICT per enrolled student per day (kWh/st/d), should be used as the primary metric for ICT energy efficiency in higher education. For other uses of electricity than ICT in higher education, we express electricity use in kilowatthours per person per day (kWh/p/d). Applying continuous monitoring and management of ICT energy is one approach one could take to increase ICT energy efficiency in education. In households, providing direct (i.e. real-time) feedback about energy use typically results in 5-15% energy savings, whereas indirect feedback (provided some time after consumption occurs), results in less energy savings, typically 0-10%. Continuous measurement of ICT electricity use can be done in a variety of ways. In this report, we distinguish and describe four major measurement approaches: (1) In-line meters, which require breaking the electrical circuit to install the meter; (2) clamp-on-meters, which can be wrapped around a wire; (3) add-ons to existing energy meters, which use analog or digital ports of existing energy meters; (4) software-only measurement, which uses existing network interfaces, protocols and APIs. A measurement approach can be used at one or more aggregation levels: at building level (to measure all electrical energy used in a building, e.g. a datacenter); at

  4. Evaluation of the impact of environmental public policy measures on energy consumption and greenhouse gas emissions in the French residential sector

    International Nuclear Information System (INIS)

    Charlier, Dorothée; Risch, Anna

    2012-01-01

    A cut in energy consumption by 2050 to reach 50 kWh pe /m 2 /year and reduce GHG emissions by 75% are important objectives of environmental policy in France. The residential sector represents a significant potential source of energy savings. In this paper, our main objective is to construct a simulation model and to evaluate the impact of environmental public policy measures. We model energy consumption and GHG emissions, the decision to invest in energy saving renovations and the dynamics of the housing stock. Particular attention is paid to household investment decisions regarding home renovation. To generate the dynamics and the structure of the housing stock through 2050, we introduce socioeconomic variables that alter the number of renovations and new constructions. This study has three major outputs. First, we estimate the energy consumption and GHG emissions of the residential sector in France through 2050. Second, we study the impact of environmental public policy measures. Lastly, we propose different means to reach the objectives. The results show that while current policies are effective, they are not sufficient to reach the objectives. - Highlights: ► We model the decision to invest in energy saving renovations and dynamics of the housing stock. ► We model and estimate the energy consumption and GHG emissions. ► We study the impact of current environmental public policy measures ► We simulate different public policies to reach the French objectives ► Results show that current policies are effective but not sufficient.

  5. Energy Efficiency Measures to Incorporate into Remodeling Projects

    Energy Technology Data Exchange (ETDEWEB)

    Liaukus, C. [Building America Research Alliance, Kent, WA (United States)

    2014-12-01

    Energy improvements in a home are often approached as one concerted effort, beginning with a simple walk-through assessment or more in-depth energy audit and followed by the installation of recommended energy measures. While this approach allows for systems thinking to guide the efforts, comprehensive energy improvements of this nature are undertaken by a relatively small number of U.S. households compared to piecemeal remodeling efforts. In this report, the U.S Department of Energy Building America Retrofit Alliance research team examines the improvement of a home’s energy performance in an opportunistic way by examining what can be done to incorporate energy efficiency measures into general remodeling work and home repair projects. This allows for energy efficiency upgrades to occur at the same time as remodeling proejcts. There are challenges to this approach, not the least of which being that the work will take place over time in potentially many separate projects. The opportunity to improve a home’s energy efficiency at one time expands or contracts with the scope of the remodel. As such, guidance on how to do each piece thoughtfully and with consideration for potential future projects, is critical.

  6. A sound and efficient measure of joint congruence.

    Science.gov (United States)

    Conconi, Michele; Castelli, Vincenzo Parenti

    2014-09-01

    In the medical world, the term "congruence" is used to describe by visual inspection how the articular surfaces mate each other, evaluating the joint capability to distribute an applied load from a purely geometrical perspective. Congruence is commonly employed for assessing articular physiology and for the comparison between normal and pathological states. A measure of it would thus represent a valuable clinical tool. Several approaches for the quantification of joint congruence have been proposed in the biomechanical literature, differing on how the articular contact is modeled. This makes it difficult to compare different measures. In particular, in previous articles a congruence measure has been presented which proved to be efficient and suitable for the clinical practice, but it was still empirically defined. This article aims at providing a sound theoretical support to this congruence measure by means of the Winkler elastic foundation contact model which, with respect to others, has the advantage to hold also for highly conforming surfaces as most of the human articulations are. First, the geometrical relation between the applied load and the resulting peak of pressure is analytically derived from the elastic foundation contact model, providing a theoretically sound approach to the definition of a congruence measure. Then, the capability of congruence measure to capture the same geometrical relation is shown. Finally, the reliability of congruence measure is discussed. © IMechE 2014.

  7. Measuring efficiency of international crude oil markets: A multifractality approach

    Science.gov (United States)

    Niere, H. M.

    2015-01-01

    The three major international crude oil markets are treated as complex systems and their multifractal properties are explored. The study covers daily prices of Brent crude, OPEC reference basket and West Texas Intermediate (WTI) crude from January 2, 2003 to January 2, 2014. A multifractal detrended fluctuation analysis (MFDFA) is employed to extract the generalized Hurst exponents in each of the time series. The generalized Hurst exponent is used to measure the degree of multifractality which in turn is used to quantify the efficiency of the three international crude oil markets. To identify whether the source of multifractality is long-range correlations or broad fat-tail distributions, shuffled data and surrogated data corresponding to each of the time series are generated. Shuffled data are obtained by randomizing the order of the price returns data. This will destroy any long-range correlation of the time series. Surrogated data is produced using the Fourier-Detrended Fluctuation Analysis (F-DFA). This is done by randomizing the phases of the price returns data in Fourier space. This will normalize the distribution of the time series. The study found that for the three crude oil markets, there is a strong dependence of the generalized Hurst exponents with respect to the order of fluctuations. This shows that the daily price time series of the markets under study have signs of multifractality. Using the degree of multifractality as a measure of efficiency, the results show that WTI is the most efficient while OPEC is the least efficient market. This implies that OPEC has the highest likelihood to be manipulated among the three markets. This reflects the fact that Brent and WTI is a very competitive market hence, it has a higher level of complexity compared against OPEC, which has a large monopoly power. Comparing with shuffled data and surrogated data, the findings suggest that for all the three crude oil markets, the multifractality is mainly due to long

  8. Dynamic Efficiency Measurements for Irradiated ATLAS Pixel Single Chip Modules

    CERN Document Server

    Pfaff, Mike; Grosse-Knetter, Jorn

    2011-01-01

    The ATLAS pixel detector is the innermost subdetector of the ATLAS experiment. Due to this, the pixel detector has to be particularly radiation hard. In this diploma thesis effects on the sensor and the electronics which are caused by irradiation are examined. It is shown how the behaviour changes between an unirradiated sample and a irradiated sample, which was treated with the same radiation dose that is expected at the end of the lifetime of ATLAS. For this study a laser system, which is used for dynamic efficiency measurements was constructed. Furthermore, the behaviour of the noise during the detection of a particle was evaluated studied.

  9. A model to improve efficiency and effectiveness of safeguards measures

    International Nuclear Information System (INIS)

    D'Amato, Eduardo; Llacer, Carlos; Vicens, Hugo

    2001-01-01

    Full text: The main purpose of our current studies is to analyse the measures to be adopted tending to integrate the traditional safeguard measures to the ones stated in the Additional Protocol (AP). A simplified nuclear fuel cycle model is considered to draw some conclusions on the application of integrated safeguard measures. This paper includes a briefing, describing the historical review that gave birth to the A.P. and proposes a model to help the control bodies in the making decision process. In May 1997, the Board of Governors approved the Model Additional Protocol (MAP) which aimed at strengthening the effectiveness and improving the efficiency of safeguard measures. For States under a comprehensive safeguard agreement the measures adopted provide credible assurance on the absence of undeclared nuclear material and activities. In September 1999, the governments of Argentina and Brazil formally announced in the Board of Governors that both countries would start preliminary consultations on one adapted MAP applied to the Agreement between the Republic of Argentina, the Federative Republic of Brazil, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials and the International Atomic Energy Agency for the Application of Safeguards (Quatripartite Agreement/INFCIRC 435). In December 1999, a first draft of the above mentioned document was provided as a starting point of discussion. During the year 2000 some modifications to the original draft took place. These were the initial steps in the process aiming at reaching the adequate conditions to adhere to the A.P. in each country in a future Having in mind the future AP implementation, the safeguards officers of the Regulatory Body of Argentina (ARN) began to think about the future simultaneous application of the two types of safeguards measures, the traditional and the non traditional ones, what should converge in an integrated system. By traditional safeguards it is understood quantitative

  10. Future Air Conditioning Energy Consumption in Developing Countries and what can be done about it: The Potential of Efficiency in the Residential Sector

    OpenAIRE

    McNeil, Michael A.; Letschert, Virginie E.

    2008-01-01

    The dynamics of air conditioning are of particular interest to energy analysts, both because of the high energy consumption of this product, but also its disproportionate impact on peak load. This paper addresses the special role of this end use as a driver of residential electricity consumption in rapidly developing economies. Recent history has shown that air conditioner ownership can grow grows more rapidly than economic growth in warm-climate countries. In 1990, less than a percent o...

  11. Energy Efficiency Measures to Incorporate into Remodeling Projects

    Energy Technology Data Exchange (ETDEWEB)

    Liaukus, C.

    2014-12-01

    Energy improvements in a home are often approached as one concerted effort, beginning with a simple walk-through assessment or more in-depth energy audit and followed by the installation of recommended energy measures. While this approach allows for systems thinking to guide the efforts, comprehensive energy improvements of this nature are undertaken by a relatively small number of the households in our nation compared to more piecemeal remodeling efforts. Even when programs like the Weatherization Assistance Program and Home Performance with ENERGY STAR are considered, homes that have had a comprehensive energy makeover still represent a small fraction of the 111.1 million households. In this report, the U.S Department of Energy Building America Retrofit Alliance research team looks at the improvement of a home's energy performance in an opportunistic way: it examines what can be done to incorporate energy efficiency measures into general remodeling work and home repair projects. This allows for the possibility for people who would not normally pursue energy efficiency but will remodel their kitchen or re-side their home to improve their home's performance at the same time. There are challenges to this approach, not the least of which being that the work will take place over time in potentially many separate projects. The opportunity to improve a home's energy efficiency at one time expands or contracts with the scope of the remodel. As such, guidance on how to do each piece thoughtfully and with consideration for potential future projects, is critical.

  12. Energy efficiency measures for offshore oil and gas platforms

    International Nuclear Information System (INIS)

    Nguyen, Tuong-Van; Voldsund, Mari; Breuhaus, Peter; Elmegaard, Brian

    2016-01-01

    Oil and gas platforms are energy-intensive systems – each facility uses from a few to several hundreds MW of energy, depending on the petroleum properties, export specifications and field lifetime. Several technologies for increasing the energy efficiency of these plants are investigated in this work. They include: (i) the installation of multiple pressure levels in production manifolds, (ii) the implementation of multiphase expanders, (iii) the promotion of energy and process integration, (iv) the limitation of gas recirculation around the compressors, (v) the exploitation of low-temperature heat from the gas cooling steps, (vi) the downsizing or replacement of the existing gas turbines, and (vii) the use of the waste heat from the power plant. The present study builds on four actual cases located in the North and Norwegian Seas, which differ by the type of oil processed, operating conditions and strategies. The benefits and practical limitations of each measure are discussed based on thermodynamic, economic and environmental factors. Significant energy savings and reductions in CO_2-emissions are depicted, reaching up to 15–20%. However, they strongly differ from one facility to another, which suggests that generic improvements can hardly be proposed, and that thorough techno-economic analyses should be conducted for each plant. - Highlights: • Energy efficiency measures for offshore platforms are assessed. • Energy savings and reductions in CO_2-emissions can reach up to 15-20%. • They differ strongly depending on the oil type, operating conditions and strategies.

  13. Development of electrical efficiency measurement techniques for 10 kW-class SOFC system: Part I. Measurement of electrical efficiency

    International Nuclear Information System (INIS)

    Tanaka, Yohei; Momma, Akihiko; Kato, Ken; Negishi, Akira; Takano, Kiyonami; Nozaki, Ken; Kato, Tohru

    2009-01-01

    Measurement techniques to estimate electrical efficiency of 10 kW-class SOFC systems fueled by town-gas were developed and demonstrated for a system developed by Kansai Electric Power Company and Mitsubishi Materials Corporation under a NEDO project. Higher heating value of the fuel was evaluated with a transportable gas sampling unit and conventional gas chromatography in AIST laboratory with thermal-conductivity and flame-ionization detectors, leading to mean value 44.69 MJ m -3 on a volumetric base for ideal-gas at the standard state (0 deg. C, 101.325 kPa). Mass-flow-rate of the fuel was estimated as 33.04 slm with a mass-flow meter for CH 4 , which was calibrated to correct CH 4 flow-rate and effect of sensitivity change and to obtain conversion factor from CH 4 to town-gas. Without calibration, systematic effect would occur by 8% in flow-rate measurement in the case for CH 4 . Power output was measured with a precision power analyzer, a virtual three phase starpoint adapter, and tri-axial shunts. Power of fundamental wave (60 Hz) was estimated as 10.14 kW, considering from total active power, total higher harmonic distortion factor, and power consumption at the starpoint adapter. The electrical efficiency was presumed to be 41.2% (HHV), though this mean value will be complete only when uncertainty estimation is accompanied

  14. Prediction of residential radon exposure of the whole Swiss population: comparison of model-based predictions with measurement-based predictions.

    Science.gov (United States)

    Hauri, D D; Huss, A; Zimmermann, F; Kuehni, C E; Röösli, M

    2013-10-01

    Radon plays an important role for human exposure to natural sources of ionizing radiation. The aim of this article is to compare two approaches to estimate mean radon exposure in the Swiss population: model-based predictions at individual level and measurement-based predictions based on measurements aggregated at municipality level. A nationwide model was used to predict radon levels in each household and for each individual based on the corresponding tectonic unit, building age, building type, soil texture, degree of urbanization, and floor. Measurement-based predictions were carried out within a health impact assessment on residential radon and lung cancer. Mean measured radon levels were corrected for the average floor distribution and weighted with population size of each municipality. Model-based predictions yielded a mean radon exposure of the Swiss population of 84.1 Bq/m(3) . Measurement-based predictions yielded an average exposure of 78 Bq/m(3) . This study demonstrates that the model- and the measurement-based predictions provided similar results. The advantage of the measurement-based approach is its simplicity, which is sufficient for assessing exposure distribution in a population. The model-based approach allows predicting radon levels at specific sites, which is needed in an epidemiological study, and the results do not depend on how the measurement sites have been selected. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. THE LEVEL OF CUSTOMER SATISFACTION - MEASURE OF SOCIAL EFFICIENCY

    Directory of Open Access Journals (Sweden)

    MUNGIU-PUPĂZAN MARIANA CLAUDIA

    2014-05-01

    Full Text Available Pricing models for social efficiency focuses on assessing the quality, namely the comparison of the desired product to the consumer and the product received, the level of consumer satisfaction on the products and / or services will be therefore a very important component in measuring the effectiveness social. Between the two concepts there is a relationship of mutual interdependence: the level of consumer satisfaction is the result of the quality performance of products and services and high quality products and services is reflected in consumer satisfaction. From the theoretical point of view, according to the marketing strategy, it is necessary to bring to a common level of perceived benefit to consumer expectations. Customer satisfaction is actually the result of a complex information processing.

  16. Dynamic steering beams for efficient force measurement in optical manipulation

    Institute of Scientific and Technical Information of China (English)

    Xiaocong Yuan; Yuquan Zhang; Rui Cao; Xing Zhao; Jing Bu; Siwei Zhu

    2011-01-01

    @@ An efficient and inexpensive method that uses a glass plate mounted onto a motorized rotating stage as a beam-steering device for the generation of dynamic optical traps is reported.Force analysis reveals that there are drag and trapping forces imposed on the bead in the opposite directions, respectively, in a viscous medium.The trapped bead will be rotated following the beam's motion before it reaches the critical escape velocity when the drag force is equal to the optical trapping force.The equilibrium condition facilitates the experimental measurement of the drag force with potential extensions to the determination of the viscosity of the medium or the refractive index of the bead.The proposed technique can easily be integrated into conventional optical microscopic systems with minimum modifications.%An efficient and inexpensive method that uses a glass plate mounted onto a motorized rotating stage as a beam-steering device for the generation of dynamic optical traps is reported. Force analysis reveals that there are drag and trapping forces imposed on the bead in the opposite directions, respectively, in a viscous medium. The trapped bead will be rotated following the beam's motion before it reaches the critical escape velocity when the drag force is equal to the optical trapping force. The equilibrium condition facilitates the experimental measurement of the drag force with potential extensions to the determination of the viscosity of the medium or the refractive index of the bead. The proposed technique can easily be integrated into conventional optical microscopic systems with minimum modifications.

  17. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  18. 78 FR 64067 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2013-10-25

    .... Inverter Controls for PSC Motors c. High-Efficiency Motors d. Multi-Stage or Modulating Heating Controls e... MPC b. Inverter-Driven PSC Costs c. Furnace Fan Motor MPC d. Motor Control Costs e. Backward-Inclined... savings is measured for the lifetime of residential furnace fans shipped in 2019-2048. The SCC values, on...

  19. A critical look at residential electricity conservation campaigns in a developing country environment

    International Nuclear Information System (INIS)

    Martino Jannuzzi, G. de; Ferreira Santos, V. dos

    1993-01-01

    This paper analyse survey results of the effectiveness of information campaigns to promote energy efficiency among residential consumers in Brazil. The survey found that consumers have a relatively good knowledge of conservation measures to improve electricity usage. Nevertheless, other approaches are needed to promote energy conservation in the household sector. (author). 3 refs, 4 figs, 2 tabs

  20. Prediction of greenhouse gas reduction potential in Japanese residential sector by residential energy end-use model

    International Nuclear Information System (INIS)

    Shimoda, Yoshiyuki; Yamaguchi, Yukio; Okamura, Tomo; Taniguchi, Ayako; Yamaguchi, Yohei

    2010-01-01

    A model is developed that simulates nationwide energy consumption of the residential sector by considering the diversity of household and building types. Since this model can simulate the energy consumption for each household and building category by dynamic energy use based on the schedule of the occupants' activities and a heating and cooling load calculation model, various kinds of energy-saving policies can be evaluated with considerable accuracy. In addition, the average energy efficiency of major electric appliances used in the residential sector and the percentages of housing insulation levels of existing houses is predicted by the 'stock transition model.' In this paper, energy consumption and CO 2 emissions in the Japanese residential sector until 2025 are predicted. For example, as a business - as-usual (BAU) case, CO 2 emissions will be reduced by 7% from the 1990 level. Also evaluated are mitigation measures such as the energy efficiency standard for home electric appliances, thermal insulation code, reduction of standby power, high-efficiency water heaters, energy-efficient behavior of occupants, and dissemination of photovoltaic panels.

  1. Inter-firm and intra-firm efficiency measures

    NARCIS (Netherlands)

    Oude Lansink, A.G.J.M.; Silva, E.; Stefanou, S.

    2001-01-01

    Intra-firm efficiency involves computing a particular firm's efficiency degree over time relative to the firm-specific production frontier. Inter-firm efficiency reveals a particular firm's performance over time relative to the ``best practice frontier'' among the set of comparable firms. These

  2. 90 measurement of technical efficiency and its determinants in crop ...

    African Journals Online (AJOL)

    OLUWOLE AKINNAGBE

    They found that education, number of working animals, credit per acre and number of extension visits significantly increased cost efficiency while large land holding size significantly decreased cost efficiency. In single estimation approach of the technical efficiency model for Indian farmers,. Colli et al (1998), found that years ...

  3. A reference pelton turbine - design and efficiency measurements

    International Nuclear Information System (INIS)

    Solemslie, Bjørn W; Dahlhaug, Ole G

    2014-01-01

    The Pelton turbine has been subject to a varying degree of research interest since the debut of the technology over a century ago. Despite its age there are gaps in the knowledge concerning the flow mechanisms effecting the flow through the turbine. A Pelton turbine has been designed at the Waterpower Laboratory at NTNU. This has been done in connection to a Ph.D. project focusing on the flow in Pelton turbine buckets. The design of the turbine has been conducted using in-house knowledge in addition to some comments from a turbine producer. To describe the geometry multiple Bezier curves were used and the design strategy aimed to give a smooth and continuous gradient along the main flow directions in the bucket. The turbine has been designed for the operational conditions of the Pelton test rig installed at the Waterpower Laboratory which is a horizontal single jet test rig with a jet diameter(d s ) of 35 mm. The diameter(D) of the runner was set to 513 mm and the width(W) of a bucket 114 mm, leading to a D/W ratio of 4.5. Manufacturing of the turbine has been carried out in aluminium and the turbine has undergone efficiency testing and visual inspection during operation at a head of 70 m. The turbine did not performed as expected and the maximum efficiency was found to be 77.75%. The low efficiency is mainly caused by a large amount of water leaving the bucket through the lip and hence transferring close to zero of its energy to the shaft. The reason for the large lip loss is discussed and two possible causes are found; the jet is located too close to the lip, and the inner surface of the bucket does not lead the water away from the lip. The turbine geometry and all data from both measurements and simulations will be available upon request in an effort to increase the amount of available data concerning Pelton turbines

  4. A reference pelton turbine - design and efficiency measurements

    Science.gov (United States)

    Solemslie, Bjørn W.; Dahlhaug, Ole G.

    2014-03-01

    The Pelton turbine has been subject to a varying degree of research interest since the debut of the technology over a century ago. Despite its age there are gaps in the knowledge concerning the flow mechanisms effecting the flow through the turbine. A Pelton turbine has been designed at the Waterpower Laboratory at NTNU. This has been done in connection to a Ph.D. project focusing on the flow in Pelton turbine buckets. The design of the turbine has been conducted using in-house knowledge in addition to some comments from a turbine producer. To describe the geometry multiple Bezier curves were used and the design strategy aimed to give a smooth and continuous gradient along the main flow directions in the bucket. The turbine has been designed for the operational conditions of the Pelton test rig installed at the Waterpower Laboratory which is a horizontal single jet test rig with a jet diameter(ds) of 35 mm. The diameter(D) of the runner was set to 513 mm and the width(W) of a bucket 114 mm, leading to a D/W ratio of 4.5. Manufacturing of the turbine has been carried out in aluminium and the turbine has undergone efficiency testing and visual inspection during operation at a head of 70 m. The turbine did not performed as expected and the maximum efficiency was found to be 77.75%. The low efficiency is mainly caused by a large amount of water leaving the bucket through the lip and hence transferring close to zero of its energy to the shaft. The reason for the large lip loss is discussed and two possible causes are found; the jet is located too close to the lip, and the inner surface of the bucket does not lead the water away from the lip. The turbine geometry and all data from both measurements and simulations will be available upon request in an effort to increase the amount of available data concerning Pelton turbines.

  5. Canada's residential school system: measuring the intergenerational impact of familial attendance on health and mental health outcomes.

    Science.gov (United States)

    Hackett, Christina; Feeny, David; Tompa, Emile

    2016-11-01

    We estimate the intergenerational relationship between the residential school (RS) attendance of an older generation family member and the physical and mental health of a younger generation. Data from the 2012 Aboriginal Peoples Survey (APS) is used to examine the relationship between previous generational family RS attendance and the current physical and mental health of off-reserve First Nations, Métis and Inuit Canadians. Five outcomes are considered (self-perceived health, mental health, distress, suicidal ideation and suicide attempt). Direct (univariate) and indirect (multivariate) effects of family RS attendance are examined for each dependent variable. We draw from the general and indigenous-specific social determinants of health literature to inform the construction of our models. Familial RS attendance is shown to affect directly all five health and mental health outcomes, and is associated with lower self-perceived health and mental health, and a higher risk for distress and suicidal behaviours. Background, mediating and structural-level variables influence the strength of association. Odds of being in lower self-perceived health remain statistically significantly higher with the presence of familial attendance of RS when controlling for all covariates. The odds of having had a suicide attempt within the past 12 months remain twice as high for those with familial attendance of RS. Health disparities exist between indigenous and non-indigenous Canadians, an important source of which is a family history of RS attendance. This has implications for clinical practice and Canadian public health, as well as countries with similar historical legacies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Austro-Hungarian Public Building Refurbishment and Energy Efficiency Measures - A Case Study on a Public Building in Sarajevo

    Science.gov (United States)

    Salihbegović, Amira; Čaušević, Amir; Rustempašić, Nerman; Avdić, Dženis; Smajlović, Esad

    2017-10-01

    Among other pieces of architectural historical heritage in Sarajevo, and Bosnia-Herzegovina in general, the Austro-Hungarian architecture has preserved its original architectural, artistic and engineering characteristics. Both residential and public representative urban blocks, streets and squares are of distinguishable ambience in the architectural and urban image of the city and are testifying about our architectural past. A number of buildings is valorised and protected by law in terms of their architectural, artistic and historical value. In addition, these buildings have a distinct functional, ambiental, historical, and even aesthetical value. To make them last longer, refurbishment of these buildings is challenging and presents potential and multiple benefits for the city, and beyond. Refurbishing built environment through functional reorganizing, redesign and energy efficiency measures applications could result in prolonged longevity, architectural identity preservation and interior comfort improvement. Besides, implemented measures for energy efficiency, through the refurbishment process, should optimize the needs for energy consumption in treated buildings. This paper defines options in comfort improvements and redesign, without implying risks to the building longevity, analyses interventions and energy efficiency measures which would enable potential energy saving assessment in the refurbishment process of masonry buildings. This paper also discusses the different techniques that can be adopted for conservation and preservation of historical masonry buildings from the Austro-Hungarian period dealing with energy efficiency. The works were preceded by historical research and on-site investigations. This paper describes a methodology to quantify their vulnerability. A scheme of structural retrofitting is suggested following the research conducted. Revitalization of the building consisted in the reconstruction of the old building structure, creating the inner

  7. A multi-objective approach for optimal prioritization of energy efficiency measures in buildings: Model, software and case studies

    International Nuclear Information System (INIS)

    Karmellos, M.; Kiprakis, A.; Mavrotas, G.

    2015-01-01

    Highlights: • We provide a model for prioritization of energy efficiency measures in buildings. • We examine the case of a new building and one under renovation. • Objective functions are total primary energy consumption and total investment cost. • We provide a software tool that solves this multi-objective optimization problem. • Primary energy consumption and investment cost are inversely proportional. - Abstract: Buildings are responsible for some 40% of the total final energy consumption in the European Union and about 40% of the world’s primary energy consumption. Hence, the reduction of primary energy consumption is important for the overall energy chain. The scope of the current work is to assess the energy efficiency measures in the residential and small commercial sector and to develop a methodology and a software tool for their optimal prioritization. The criteria used for the prioritization of energy efficiency measures in this article are the primary energy consumption and the initial investment cost. The developed methodology used is generic and could be implemented in the case of a new building or retrofitting an existing building. A multi-objective mixed-integer non-linear problem (MINLP) needs to be solved and the weighted sum method is used. Moreover, the novelty of this work is that a software tool has been developed using ‘Matlab®’ which is generic, very simple and time efficient and can be used by a Decision Maker (DM). Two case studies have been developed, one for a new building and one for retrofitting an existing one, in two cities with different climate characteristics. The building was placed in Edinburgh in the UK and Athens in Greece and the analysis showed that the primary energy consumption and the initial investment cost are inversely proportional

  8. Suggestions on Strengthening Greening Construction of Ecological Residential Areas

    OpenAIRE

    Li, Peng

    2013-01-01

    Greening construction is an important part of the construction of ecological residential areas, but there exist some misunderstandings in greening construction of ecological residential districts at present. Based on the description of functions of green space in ecological residential areas, the summarization of principles of greening design, and the discussion of questions in greening construction of ecological residential districts, some suggestions as well as specific measures for strengt...

  9. Zones 30 : urban residential areas.

    NARCIS (Netherlands)

    2006-01-01

    Sustainable Safety uses a road categorization in which through traffic is concentrated on motorways and other main roads. In residential areas, which have a living, shopping, or work function, through traffic is discouraged by setting a speed limit of 30 km/h, and by speed reducing measures such as

  10. Estimation of European Union residential sector space cooling potential

    International Nuclear Information System (INIS)

    Jakubcionis, Mindaugas; Carlsson, Johan

    2017-01-01

    Data on European residential space cooling demands are scarce and often of poor quality. This can be concluded from a review of the Comprehensive Assessments on the energy efficiency potential in the heating and cooling sector performed by European Union Member States under Art. 14 of the Energy Efficiency Directive. This article estimates the potential space cooling demands in the residential sector of the EU and the resulting impact on electricity generation and supply systems using the United States as a proxy. A georeferenced approach was used to establish the potential residential space cooling demand in NUTS-3 regions of EU. The total potential space cooling demand of the EU was estimated to be 292 TW h for the residential sector in an average year. The additional electrical capacity needed was estimated to 79 GW. With proper energy system development strategies, e.g. matching capacity of solar PV with cooling demand, or introduction of district cooling, the stresses on electricity system from increasing cooling demand can be mitigated. The estimated potential of space cooling demand, identified in this paper for all EU Members States, could be used while preparing the next iteration of EU MS Comprehensive Assessments or other energy related studies. - Highlights: • An estimation of EU space cooling demand potential in residential sector is presented. • An estimate of space cooling demand potential is based on using USA data as a proxy. • Significant cooling demand increase can be expected. • Cooling demand increase would lead to increased stress in energy supply systems. • Proper policies and strategies might measurably decrease the impact on energy systems.

  11. Efficient iris texture analysis method based on Gabor ordinal measures

    Science.gov (United States)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  12. The Multiple Benefits of Measures to Improve Energy Efficiency

    DEFF Research Database (Denmark)

    Puig, Daniel; Farrell, Timothy Clifford

    Understanding the barriers to, and enablers for, energy efficiency requires targeted information and analysis. This report is a summary of four detailed studies providing new insights on how to promote efficiency in selected priority areas. It complements initiatives such as the so-called energy...... efficiency accelerators, which seek to increase the uptake of selected technologies, as well as the work of many other institutions committed to improving energy efficiency. The modelling estimates and the case studies presented in this report illustrate that, while significant progress has already been...... achieved, the case for accelerating energy efficiency action is strong. Key highlights include: • At the global level, energy efficiency improvements would account for between 2.6 and 3.3 Gt CO2e of the reductions in 2030, equivalent to between 23 and 26 percent of the overall reductions achieved...

  13. Changes in production efficiency in China identification and measuring

    CERN Document Server

    Xu, Bing; Watada, Junzo

    2014-01-01

    Evaluating  Production Efficiency in China examines production from engineering and statistics perspectives rather than from economics and mathematics perspectives. The authors present an observable benchmark as the criterion of the production efficiency to replace the unobservable production frontier surface. This book discusses several different computing technologies, controllable variable as a path of identification, changes in production efficiency by decision making on specific operating conditions, and optimal resource allocation. The book provides a channel to tap inside the success stories of China, exploiting the way of changes in production efficiency during China’s development in the past 30 years. This book examines the concepts and realization of production efficiencies across all areas of the economy. Also the book provides the perspective of foreign direct investment (FDI) absorption to identify how Chinese economy changes in production efficiency.

  14. 10 CFR 431.16 - Test procedures for the measurement of energy efficiency.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.16 Section 431.16 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... Methods of Determining Efficiency § 431.16 Test procedures for the measurement of energy efficiency. For...

  15. Measuring Energy Efficiency in China’s Transport Sector

    Directory of Open Access Journals (Sweden)

    Han Hao

    2017-05-01

    Full Text Available Energy efficiency is one of the key factors affecting energy consumption and greenhouse gas (GHG emissions. By focusing on China’s transport sector, this study comprehensively reviews and compares the energy efficiency performance of passenger vehicles, light-duty commercial vehicles, commercial road transport, commercial water transport, aviation transport and railway transport, and identifies the opportunities for further energy efficiency improvements. It is found that railway transport exhibited the greatest improvement in energy efficiency during the past decade, which was mainly driven by progress in its electrification. Passenger vehicles have also experienced considerable energy efficiency improvements, which can be mainly attributed to the establishment of mandatory fuel consumption standards. In contrast, commercial road transport has shown the least improvement, due to insufficient policy implementations. Based on the analysis, it is recommended that, as China’s present policy framework to improve energy efficiency in the transport sector is generally effective, it should be consistently maintained and successively improved. Electrification represents a major opportunity for improvement of energy efficiency in the transport sector. Such potential should be fully tapped for all transport modes. Greater effort should be put into improving the energy efficiency of commercial road transport. The policy instruments utilized to improve the energy efficiency of heavy-duty vehicles should be as intensive and effective as the policy instruments for passenger vehicles.

  16. Measuring the operational efficiency of individual theme park attractions.

    Science.gov (United States)

    Kim, Changhee; Kim, Soowook

    2016-01-01

    This study assesses the operation efficiency of theme park attractions using the data envelopment analysis, utilizing actual data on 15 attractions at Samsung Everland located in Yongin-si, Republic of Korea. In particular, this study identifies crowding and waiting time as one of the main causes of visitor's satisfaction, and analyzes the efficiency of individual attractions in terms of waiting time. The installation area, installation cost, and annual repair cost are set as input factors and the number of annual users and customer satisfaction as output factors. The results show that the roller coaster-type attractions were less efficient than other types of attractions while rotating-type attractions were relatively more efficient. However, an importance performance analysis on individual attraction's efficiency and satisfaction showed that operational efficiency should not be the sole consideration in attraction installation. In addition, the projection points for input factors for efficient use of attractions and the appropriate reference set for benchmarking are provided as guideline for attraction efficiency management.

  17. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  18. Using Data Envelopment Analysis to Measure International Agricultural Efficiency and Productivity

    OpenAIRE

    Arnade, Carlos Anthony

    1994-01-01

    Numerous methods for measuring multifactor productivity have been used by economists. This report uses a recently developed approach, data envlopment analysis, to measure productivity. This method can be used not only to calculate productivity but also to divide productivity measures into indices that measure technical efficiency and technical change. Technical efficiency measures the efficiency with which resources are used. Technical change measures changes in output arising from improved t...

  19. Temporal and Other Exposure Aspects of Residential Magnetic Fields Measurement in Relation to Acute Lymphoblastic Leukaemia in Children: The National Cancer Institute Children's Cancer Group Study (invited paper)

    International Nuclear Information System (INIS)

    Baris, D.; Linet, M.; Auvinen, A.; Kaune, W.T.; Wacholder, S.; Kleinerman, R.; Hatch, E.; Robison, L.; Niwa, S.; Haines, C.; Tarone, R.E.

    1999-01-01

    Case-control studies have used a variety of measurements to evaluate the relationship of children's exposure to magnetic fields (50 or 60 Hz) with childhood leukaemia and other childhood cancers. In the absence of knowledge about which exposure metrics may be biologically meaningful, studies during the past 10 years have often used time-weighted average (TWA) summaries of home measurements. Recently, other exposure metrics have been suggested, usually based on theoretical considerations or limited laboratory data. In this paper, the rationale and associated preliminary studies undertaken are described as well as feasibility and validity issues governing the choice of the primary magnetic field exposure assessment methods and summary metric used to estimate children's exposure in the National Cancer Institute/Children's Cancer Group (NCI/CCG) case-control study. Also provided are definitions and discussion of the strengths and weaknesses of the various exposure metrics used in exploratory analyses of the NCI/CCG measurement data. Exposure metrics evaluated include measures of central tendency (mean, median, 30th to 70th percentiles), peak exposures (90th and higher percentiles, peak values of the 24 h measurements), and measurements of short-term temporal variability (rate of change). This report describes correlations of the various metrics with the time-weighted average for the 24 h period (TWA-24-h). Most of the metrics were found to be positively and highly correlated with TWA-24-h, but lower correlations of TWA-24-h with peak exposure and with rate of change were observed. To examine further the relation between TWA and alternative metrics, similar exploratory analysis should be considered for existing data sets and for forthcoming measurement investigations of residential magnetic fields and childhood leukaemia. (author)

  20. Bootstrapped efficiency measures of oil blocks in Angola

    International Nuclear Information System (INIS)

    Barros, C.P.; Assaf, A.

    2009-01-01

    This paper investigates the technical efficiency of Angola oil blocks over the period 2002-2007. A double bootstrap data envelopment analysis (DEA) model is adopted composed in the first stage of a DEA-variable returns to scale (VRS) model and then followed in the second stage by a bootstrapped truncated regression. Results showed that on average, the technical efficiency has fluctuated over the period of study, but deep and ultradeep oil blocks have generally maintained a consistent efficiency level. Policy implications are derived.

  1. Measuring the Efficiency of Financial Inputs for Entrepreneurship

    OpenAIRE

    Lakshmi Balasubramanyan

    2009-01-01

    This study employs data on small businesses from the Office of Advocacy for the U.S. Small Business Administration, along with the Federal Deposit Insurance Corporation Call Report data for U.S. commercial banks. It examines the efficiency of the impact of the financial inputs on small business entrepreneurial output. This study provides a metric to capture financial input efficiency to the entrepreneurial process. The metric obtained from this analysis is useful for identification and adopti...

  2. Measuring the efficiency of large pharmaceutical companies: an industry analysis.

    Science.gov (United States)

    Gascón, Fernando; Lozano, Jesús; Ponte, Borja; de la Fuente, David

    2017-06-01

    This paper evaluates the relative efficiency of a sample of 37 large pharmaceutical laboratories in the period 2008-2013 using a data envelopment analysis (DEA) approach. We describe in detail the procedure followed to select and construct relevant inputs and outputs that characterize the production and innovation activity of these pharmaceutical firms. Models are estimated with financial information from Datastream, including R&D investment, and the number of new drugs authorized by the European Medicines Agency (EMA) and the US Food and Drug Administration (FDA) considering the time effect. The relative performances of these firms-taking into consideration the strategic importance of R&D-suggest that the pharmaceutical industry is a highly competitive sector given that there are many laboratories at the efficient frontier and many inefficient laboratories close to this border. Additionally, we use data from S&P Capital IQ to analyze 2071 financial transactions announced by our sample of laboratories as an alternative way to gain access to new drugs, and we link these transactions with R&D investment and DEA efficiency. We find that efficient laboratories make on average more financial transactions, and the relative size of each transaction is larger. However, pharmaceutical companies that simultaneously are more efficient and invest more internally in R&D announce smaller transactions relative to total assets.

  3. Efficient energy management measures in steel industry for economic utilization

    Directory of Open Access Journals (Sweden)

    Gurinderbir Singh Grewal

    2016-11-01

    Full Text Available The application of energy efficient Induction Machines (IM is explained in reference to power consumption savings. In energy efficient IM, losses for various Horse Power (HP ratings are summarized for bringing effective changes in design. Emphasis is laid on how load factor, speed & power quality affect machine’s efficiency. Replacement of conventional IM of higher power rating is done with required energy efficient Doubly Fed Induction Machine (DFIM to enhance the performance at variable speeds near rated power outputs. Results of the proposed approach will give substantial savings in energy & loss reduction. The field data of Jindal Steel Rolling Mill (JSRM at Hisar, Haryana (India is taken into consideration. This paper proposes a non-intrusive air gap torque method for efficiency estimation of in-service IMs. This approach gives results considering stray-load and friction-windage loss according to IEC standard and IEEE112-B standard. The proposed method is validated experimentally whose effectiveness is witnessed using MATLAB/SIMULINK.

  4. Measuring and Explaining Airport Efficiency and Sustainability: Evidence from Italy

    Directory of Open Access Journals (Sweden)

    Fabio Carlucci

    2018-02-01

    Full Text Available From an environmental point of view, it is widely recognized in economic literature that an efficient management of regional airports produces positive effects both for congestion reduction in the larger airports and for better use of existing infrastructures. Regional airports generally suffer from economic vulnerabilities because of scarcity of traffic volume; besides, their small catchment areas often determine low cash flow levels. As a result, significant problems of economic sustainability arise. In this context, airport infrastructure providers have the incentive to hide failures in their strategic decisions, justifying the low share of cost recovery through market characteristics. By means of the DEA (Data Envelopment Analysis method this paper analyses overall technical, pure technical, and scale efficiency of 34 Italian airports in the period 2006–2016 in order to investigate how a number of factors impact on the efficiency and economic sustainability of regional airports. Our findings reveal that airport size, presence of low-cost carriers and cargo traffic have a significant influence on the technical and scale efficiency of Italian airports. In other words, air transport privatization and deregulation can positively affect regional airport efficiency and sustainability. This is to say that the market mechanism is a useful tool in achieving regional airport sustainability even if the empirical analysis of the effects of privatization and deregulation is recommended for evaluating such political programs.

  5. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  6. Development of Residential SOFC Cogeneration System

    International Nuclear Information System (INIS)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-01-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the 'Demonstrative Research on Solid Oxide Fuel Cells' Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  7. Technology change and energy consumption: A comparison of residential subdivisions

    Science.gov (United States)

    Nieves, L. A.; Nieves, A. L.

    The energy savings in residential buildings likely to result from implementation of the building energy performance standards (BEPS) were assessed. The goals were to: compare energy use in new homes designed to meet or exceed BEPS levels of energy efficiency with that in similar but older homes designed to meet conventional building codes, and to survey the home owners regarding their energy conservation attitudes and behaviors and to ascertain the degree to which conservation attitudes and behaviors are related to residential energy use. The consumer demand theory which provides the framework for the empirical analysis is presented. The sample residences are described and the data collection method discussed. The definition and measurement of major variables are presented.

  8. Measuring the Influence of Efficient Ports using Social Network Metrics

    Directory of Open Access Journals (Sweden)

    Byung-Hak Leem

    2015-02-01

    Full Text Available Data envelopment analysis (DEA is known as a useful tool that produces many efficient decision-making units (DMUs. Traditional DEA provides relative efficient scores and reference sets, but does not influence and rank the efficient DMUs. This paper suggests a method that provides influence and ranking information by using PageRank as a centrality of Social Network analysis (SNA based on reference sets and their lambda values. The social network structure expresses the DMU as a node, reference sets as link, and lambda as connection strengths or weights. This paper, with PageRank, compares the Eigenvector centrality suggested by Liu, et al. in 2009, and shows that PageRank centrality is more accurate.

  9. Radiochemical methods to enhance efficiency of α-spectral measurements

    International Nuclear Information System (INIS)

    Silkina, G.P.; Artem'ev, O.I.

    2001-01-01

    The paper describes possible ways to improve a plutonium radiochemical separation technique developed in the Khlopin Radium Institute and modify it to account for the site-specific features of samples from the former Semipalatinsk test site (STS) and enhance the alpha spectrometry efficiency.The paper describes possible ways to improve a plutonium radiochemical separation technique developed in the Khlopin Radium Institute and modify it to account for the site-specific features of samples from the former Semipalatinsk test site (STS) and enhance the alpha spectrometry efficiency. (author)

  10. Efficiency, Effectiveness and Productivity: The Abstract Measures of ...

    African Journals Online (AJOL)

    This paper makes a case for reviving the system. Efficiency, effectiveness and productivity which are all quality indices are carefully discussed and synthesized into management techniques that will create in the staff and management officials the culture of excellent performance in our higher educational system.

  11. Measurement of farm level efficiency of home gardens in Uyo ...

    African Journals Online (AJOL)

    To investigate the farm level efficiency of home vegetable gardens in Uyo, a stochastic production function which incorporates a model for the technical inefficiency effects was used. Using farm-level data from 80 home gardeners obtained through structured questionnaire, the parameters were estimated simultaneously with ...

  12. Measuring efficiency in health care: analytic techniques and health policy

    National Research Council Canada - National Science Library

    Smith, Peter C; Street, Andrew; Jacobs, Rowena

    2006-01-01

    ... the efficiency of systems and organisations, including data envelopment analysis and stochastic frontier analysis, and also presents some promising new methodological approaches. Such techniques offer the prospect of many new and fruitful insights into health care performance. Nevertheless, they also pose many practical and methodological c...

  13. Simple and efficient methods for isolation and activity measurement ...

    African Journals Online (AJOL)

    Jane

    2011-06-29

    Jun 29, 2011 ... Key words: Hirudin, thrombin titration method, chromatography, purification. INTRODUCTION. Since recombinant ... Escherichia coli in 1986, intensive research had been .... mixed with 50 µl sample was incubated in 37°C water for 5 min, then 5 µl .... conclusion, the concise and efficient isolation line of the.

  14. 10 CFR 431.444 - Test procedures for the measurement of energy efficiency.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.444 Section 431.444 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... procedures for the measurement of energy efficiency. (a) Scope. Pursuant to section 346(b)(1) of EPCA, this...

  15. CHILDREN'S RESIDENTIAL EXPOSURE TO CHLORPYRIFOS: APPLICATION OF CPPAES FIELD MEASUREMENTS OF CHLORPYRIFOS AND TCPY WITHIN MENTOR/SHEDS PESTICIDES MODEL

    Science.gov (United States)

    The comprehensive individual field-measurements on non-dietary exposure collected in the Children's-Post-Pesticide-Application-Exposure-Study (CPPAES) were used within MENTOR/SHEDS-Pesticides, a physically based stochastic human exposure and dose model. In this application, howev...

  16. Children's residential exposure to chlorpyrifos: Application of CPPAES field measurements of chlorpyrifos and TCPy within MENTOR/SHEDS-Pesticides model

    Energy Technology Data Exchange (ETDEWEB)

    Hore, Paromita [Environmental and Occupational Health Sciences Institute (EOHSI), Rutgers University and the University of Medicine and Dentistry of New Jersey (UMDNJ), Robert Wood Johnson Medical School, 170 Frelinghuysen Road, Piscataway, NJ 08855 (United States)]|[New York City Department of Health, 253 Broadway New York, New York 10007 (United States); Zartarian, Valerie; Xue Jianping; Ozkaynak, Haluk [National Exposure Research Laboratory, U.S. EPA, 109 TW Alexander Drive, Research Triangle Park, NC 27709 (United States); Wang, S.-W.; Yang, Y.-C.; Chu, P.-Ling; Robson, Mark; Georgopoulos, Panos [Environmental and Occupational Health Sciences Institute (EOHSI), Rutgers University and the University of Medicine and Dentistry of New Jersey (UMDNJ), Robert Wood Johnson Medical School, 170 Frelinghuysen Road, Piscataway, NJ 08855 (United States); Sheldon, Linda [National Exposure Research Laboratory, U.S. EPA, 109 TW Alexander Drive, Research Triangle Park, NC 27709 (United States); Needham, Larry Barr, Dana [Contemporary Pesticide Laboratory, Centers for Disease Control, 4770 Buford Highway, Atlanta, GA 30341 (United States); Freeman, Natalie [Environmental and Occupational Health Sciences Institute (EOHSI), Rutgers University and the University of Medicine and Dentistry of New Jersey (UMDNJ), Robert Wood Johnson Medical School, 170 Frelinghuysen Road, Piscataway, NJ 08855 (United States)]|[University of Florida, Gainesville, FL 32611 (United States); Lioy, Paul J. [Environmental and Occupational Health Sciences Institute (EOHSI), Rutgers University and the University of Medicine and Dentistry of New Jersey (UMDNJ), Robert Wood Johnson Medical School, 170 Frelinghuysen Road, Piscataway, NJ 08855 (United States)]. E-mail: plioy@eohsi.rutgers.edu

    2006-08-01

    The comprehensive individual field-measurements on non-dietary exposure collected in the Children's-Post-Pesticide-Application-Exposure-Study (CPPAES) were used within MENTOR/SHEDS-Pesticides, a physically based stochastic human exposure and dose model. In this application, however, the model was run deterministically. The MENTOR/SHEDS-Pesticides employed the CPPAES as input variables to simulate the exposure and the dose profiles for seven children over a 2-week post-application period following a routine residential and professional indoor crack-and-crevice chlorpyrifos application. The input variables were obtained from a personal activity diary, microenvironmental measurements and personal biomonitoring data obtained from CPPAES samples collected from the individual children and in their homes. Simulation results were compared with CPPAES field measured values obtained from the children's homes to assess the utility of the different microenvironmental data collected in CPPAES, i.e. indicator toys and wipe samplers to estimate aggregate exposures that can be result from one or more exposure pathways and routes. The final analyses of the database involved comparisons of the actual data obtained from the individual biomarker samples of a urinary metabolite of chlorpyrifos (TCPy) and the values predicted by MENTOR/SHEDS-Pesticides using the CPPAES-derived variables. Because duplicate diet samples were not part of the CPPAES study design, SHEDs-Pesticides simulated dose profiles did not account for the dietary route. The research provided more confidence in the types of data that can be used in the inhalation and dermal contact modules of MENTOR/SHEDS-Pesticides to predict the pesticide dose received by a child. It was determined that we still need additional understanding about: (1) the types of activities and durations of activities that result in non-dietary ingestion of pesticides and (2) the influence of dietary exposures on the levels of TCPy found

  17. MEASURES FOR A PRUDENTIAL EFFICIENCY SURVEILLANCE OF CREDIT INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    Medar Lucian-Ion

    2009-05-01

    Full Text Available In this period of financial crisis, the efficiency and profitability of the banking sector received a strong blow and therefore, the banking prudence is a constant concern to all entities that comprise the European banking system. Major role in Romania of National Bank of Romania is to prevent systemic risk by promoting effective banking supervision, in order to ensure achievement of stability for entirely banking system.

  18. The perspectives of cogeneration as a mechanism to implement the rational and efficient use of energy in the industrial, residential and commercial sectors for the next decade; As perspectivas da cogeracao como mecanismo de implementacao do uso racional e eficiente de energia, nos setores industrial, residencial e comercial para a proxima decada

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Liodoro de; Santos, Adilson Francisco dos; Domingos, Sergio Ricardo; Haddad, Jamil [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Grupo de Estudos Energeticos], e-mail: mellostopa@pop.com.br

    2004-07-01

    The present work analyzes the advantages of the use of the cogeneration combined 'production of electricity and useful heat', and 'his/her correlation with the rational and efficient use of energy in Brazil in the systems: industrial, residential and commercial.' In the measure of adoptions of new energy politics the proposed system presents comparative advantages in relation to other renewable sources or not of energy. Lens to improve the factor capacity and to minimize the wastes, specifically in the final uses. The crisis of provisioning that devastated the country in 2001 serves as alert for all of the agents of the electric section. The society forced to adopt use procedures and to reuse of the consumed energy, under penalty of sanctions, from the application of fines, until the interruption of the supply she enters in a new phase, for yours, time the theme rational and efficient use of energy assumes extremely important and decisive paper of the politics of administration of the scarce energy inputs. With base in these data the cogeneration appears, as real and viable alternative, that it gets to conjugate the efficient use of the energy with advantages environmental, technological and, above all, economical contributing with the energy planning. (author)

  19. Transmission efficiency measurement at the FNAL 4-rod RFQ

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J. P. [Fermilab; Garcia, F. G. [Fermilab; Ostiguy, J. F. [Fermilab; Saini, A. [Fermilab; Zwaska, R. [Fermilab; Mustapha, B. [Argonne; Ostroumov, P. [Argonne

    2014-12-01

    This paper presents measurements of the beam transmission performed on the 4-rod RFQ currently under operation at Fermilab. The beam current has been measured at the RFQ exit as a function of the magnetic field strength in the two LEBT solenoids. This measurement is compared with scans performed on the FermiGrid with the beam dynamics code TRACK. A particular attention is given to the impact, on the RFQ beam transmission, of the space-charge neutralization in the LEBT.

  20. Chapter 20: Data Center IT Efficiency Measures Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Huang, Robert [The Cadmus Group, Portland, OR (United States); Masanet, Eric [Northwestern Univ., Evanston, IL (United States)

    2017-11-02

    This chapter focuses on IT measures in the data center and examines the techniques and analysis methods used to verify savings that result from improving the efficiency of two specific pieces of IT equipment: servers and data storage.

  1. Energy data sourcebook for the US residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, T.P.; Koomey, J.G.; Sanchez, M. [and others

    1997-09-01

    Analysts assessing policies and programs to improve energy efficiency in the residential sector require disparate input data from a variety of sources. This sourcebook, which updates a previous report, compiles these input data into a single location. The data provided include information on end-use unit energy consumption (UEC) values of appliances and equipment efficiency; historical and current appliance and equipment market shares; appliances and equipment efficiency and sales trends; appliance and equipment efficiency standards; cost vs. efficiency data for appliances and equipment; product lifetime estimates; thermal shell characteristics of buildings; heating and cooling loads; shell measure cost data for new and retrofit buildings; baseline housing stocks; forecasts of housing starts; and forecasts of energy prices and other economic drivers. This report is the essential sourcebook for policy analysts interested in residential sector energy use. The report can be downloaded from the Web at http://enduse.lbl. gov/Projects/RED.html. Future updates to the report, errata, and related links, will also be posted at this address.

  2. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  3. Measuring effects of climate change and energy efficiency regulations in U.S. households

    Science.gov (United States)

    Koirala, Bishwa Shakha

    The first chapter explains the human causes of climate change and its costs, which is estimated to be about 3.6% of GDP by the end of 21 st century (NRDC, 2008). The second chapter investigates how projected July temperatures will increase the demand for electricity in the U.S. by 0.8%, while projected January temperatures will decrease the demand for natural gas and heating oil by 1% and 2.3%, respectively. This chapter further examines effects of the energy-efficiency building codes: IECC 2003 and IECC 2006 in the U.S. in reducing the energy consumption in the U.S. households. This study finds that these state-level building codes are effective in reducing energy demand. Adoption of these codes reduces the electricity demand by 1.8%, natural gas by 1.3% and heating oil by 2.8%. A total of about 7.54 MMT per year emission reduction of CO2 is possible from the residential sector by applying such energy-efficiency building codes. This chapter further estimates an average of 1,342 kWh/Month of electricity consumption, 3,429 CFt/Month of natural gas consumption and 277 Gallon/Year of heating oil consumption per household. It also indentifies the existence of state heterogeneity that affects household level energy demand, and finds that assumption of independence of error term is violated. Chapter 3 estimates the implicit prices of climate in dollar by analyzing the hedonic rent and wage models for homeowners and apartment renters. The estimated results show that January temperature is a disamenity for which both homeowners and renters are being compensated (negative marginal willingness to pay) through U.S. by 16 and 25 at the 2004 price level per month, respectively. It also finds that the January temperature is productive, whereas the July temperatures and annual precipitation are amenities and less productive. This study suggests that households would be willing to pay for higher temperature and increased precipitation; the estimated threshold point for July

  4. Measurement of carbon capture efficiency and stored carbon leakage

    Science.gov (United States)

    Keeling, Ralph F.; Dubey, Manvendra K.

    2013-01-29

    Data representative of a measured carbon dioxide (CO.sub.2) concentration and of a measured oxygen (O.sub.2) concentration at a measurement location can be used to determine whether the measured carbon dioxide concentration at the measurement location is elevated relative to a baseline carbon dioxide concentration due to escape of carbon dioxide from a source associated with a carbon capture and storage process. Optionally, the data can be used to quantify a carbon dioxide concentration increase at the first location that is attributable to escape of carbon dioxide from the source and to calculate a rate of escape of carbon dioxide from the source by executing a model of gas-phase transport using at least the first carbon dioxide concentration increase. Related systems, methods, and articles of manufacture are also described.

  5. Evaluating airline energy efficiency: An integrated approach with Network Epsilon-based Measure and Network Slacks-based Measure

    International Nuclear Information System (INIS)

    Xu, Xin; Cui, Qiang

    2017-01-01

    This paper focuses on evaluating airline energy efficiency, which is firstly divided into four stages: Operations Stage, Fleet Maintenance Stage, Services Stage and Sales Stage. The new four-stage network structure of airline energy efficiency is a modification of existing models. A new approach, integrated with Network Epsilon-based Measure and Network Slacks-based Measure, is applied to assess the overall energy efficiency and divisional efficiency of 19 international airlines from 2008 to 2014. The influencing factors of airline energy efficiency are analyzed through the regression analysis. The results indicate the followings: 1. The integrated model can identify the benchmarking airlines in the overall system and stages. 2. Most airlines' energy efficiencies keep steady during the period, except for some sharply fluctuations. The efficiency decreases mainly centralized in the year 2008–2011, affected by the financial crisis in the USA. 3. The average age of fleet is positively correlated with the overall energy efficiency, and each divisional efficiency has different significant influencing factors. - Highlights: • An integrated approach with Network Epsilon-based Measure and Network Slacks-based Measure is developed. • 19 airlines' energy efficiencies are evaluated. • Garuda Indonesia has the highest overall energy efficiency.

  6. Consistent and efficient processing of ADCP streamflow measurements

    Science.gov (United States)

    Mueller, David S.; Constantinescu, George; Garcia, Marcelo H.; Hanes, Dan

    2016-01-01

    The use of Acoustic Doppler Current Profilers (ADCPs) from a moving boat is a commonly used method for measuring streamflow. Currently, the algorithms used to compute the average depth, compute edge discharge, identify invalid data, and estimate velocity and discharge for invalid data vary among manufacturers. These differences could result in different discharges being computed from identical data. Consistent computational algorithm, automated filtering, and quality assessment of ADCP streamflow measurements that are independent of the ADCP manufacturer are being developed in a software program that can process ADCP moving-boat discharge measurements independent of the ADCP used to collect the data.

  7. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  8. Potential energy savings by using direct current for residential applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2017-01-01

    improvement in the power converter units. However, for residential applications, the efficiency is not always improved. A grid connected residential microgrid, with renewable energy sources (RES), energy storage systems (ESS) and local loads, is presented in this work. The microgrid has been modelled...

  9. Bayesian importance parameter modeling of misaligned predictors: soil metal measures related to residential history and intellectual disability in children.

    Science.gov (United States)

    Onicescu, Georgiana; Lawson, Andrew B; McDermott, Suzanne; Aelion, C Marjorie; Cai, Bo

    2014-09-01

    In this paper, we propose a novel spatial importance parameter hierarchical logistic regression modeling approach that includes measurement error from misalignment. We apply this model to study the relationship between the estimated concentration of soil metals at the residence of mothers and the development of intellectual disability (ID) in their children. The data consist of monthly computerized claims data about the prenatal experience of pregnant women living in nine areas within South Carolina and insured by Medicaid during January 1, 1996 and December 31, 2001 and the outcome of ID in their children during early childhood. We excluded mother-child pairs if the mother moved to an unknown location during pregnancy. We identified an association of the ID outcome with arsenic (As) and mercury (Hg) concentration in soil during pregnancy, controlling for infant sex, maternal race, mother's age, and gestational weeks at delivery. There is some indication that Hg has a slightly higher importance in the third and fourth months of pregnancy, while As has a more uniform effect over all the months with a suggestion of a slight increase in risk in later months.

  10. Internal Combustion Engines as the Main Source of Ultrafine Particles in Residential Neighborhoods: Field Measurements in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Jitka Stolcpartova

    2015-11-01

    Full Text Available Ultrafine particles (UFP, diameter < 100 nm exposure has already been associated with adverse effects on human health. Spatial distribution of UFP is non-uniform; they concentrate in the vicinity of the source, e.g. traffic, because of their short lifespan. This work investigates spatial distribution of UFP in three areas in the Czech Republic with different traffic load: High traffic (Prague neighborhood—Sporilov, commuter road vicinity (Libeznice, and a small city with only local traffic (Celakovice. Size-resolved measurements of particles in the 5–500 nm range were taken with a particle classifier mounted, along with batteries, GPS and other accessories, on a handcart and pushed around the areas, making one-minute or longer stops at places of interest. Concentrations along main roads were elevated in comparison with places farther from the road; this pattern was observed in all sites, while particle number distributions both close and away from main roads had similar patterns. The absence of larger particles, the relative absence of higher concentrations of particles away from the main roads, and similar number distributions suggest that high particle number concentrations cannot be readily attributed to sources other than internal combustion engines in vehicles and mobile machinery (i.e., mowers and construction machines.

  11. The efficiency cost of protective measures in climate policy

    International Nuclear Information System (INIS)

    Böhringer, Christoph; Garcia-Muros, Xaquin; Cazcarro, Ignacio; Arto, Iñaki

    2017-01-01

    Despite recent achievements towards a global climate agreement, climate action to reduce greenhouse gas emissions remains quite heterogeneous across countries. Energy-intensive and trade-exposed (EITE) industries in industrialized countries are concerned on stringent domestic emission pricing that puts them at a competitive disadvantage against producers of similar goods in other countries with more lenient emission regulation. This paper focuses on climate policy design in the United States of America (US) and compares the economic implications of four alternative protective measures for US EITE industries: (i) output-based rebates, (ii) exemptions from emission pricing, (iii) energy intensity standards, and (iv) carbon intensity standards. Using a large-scale computable general equilibrium model we quantify how these protective measures affect competitiveness of US EITE industries. We find that protective measures can improve common trade-related competitiveness indicators such as revealed comparative advantage or relative world trade shares but at the same time may lead to a decline in the output value for EITE industries because of negative income effects. The economy-wide cost of emission abatement under protective measures increase as compared to uniform emission pricing stand-alone such that the gains of protective measures for EITE exports may be more than compensated through losses in domestic EITE demand. - Highlights: • We assess impacts for US emission-intensive and trade-exposed (EITE) industries. • EITE impacts are quantified via competitiveness metrics and production output. • Protective measures reduce adverse competitiveness impacts but can depress output. • Output losses are due to negative income effects that reduce domestic EITE demand. • Protective measures run the risk of making US climate policy much more costly.

  12. Design challenges for a climate adaptive multi-functional lightweight prefab panel for energy-efficient retrofitting of residential building based on one-room model simulations

    NARCIS (Netherlands)

    Dijkmans, T.J.A.; Donkervoort, D.R.; Phaff, J.C.; Valcke, S.L.A.

    2014-01-01

    Current solutions for highly energy-efficient retrofitting rely on thick static insulation, airtight construction and extensive ventilation systems to become independent from variable outdoor conditions. A building skin that adapts to the outdoor conditions to regulate the indoor conditions could

  13. Water Availability as a Measure of Cellulose Hydrolysis Efficiency

    DEFF Research Database (Denmark)

    Hsieh, Chia-Wen

    of sugars, salts, and surfactants impact the water relaxation time. Systems with high concentrations of sugars and salts tend to have low water availability, as these form strong interactions with water to keep their solubility, leaving less water available for hydrolysis. Thus, cellulase performance...... decreases. However, the addition of surfactants such as polyethylene glycol (PEG) increases the water mobility, leading to higher water availability, and ultimately higher glucose production. More specifically, the higher water availability boosts the activity of processive cellulases. Thus, water...... availability is vital for efficient hydrolysis, especially at high dry matter content where water availability is low. At high dry matter content, cellulase activity changes water interactions with biomass, affecting the water mobility. While swelling and fiber loosening also take place during hydrolysis...

  14. Numerical simulation of energy efficiency measures: control and operational strategies

    International Nuclear Information System (INIS)

    Ardehali, M. M.

    2006-01-01

    The inherent limitation in performance of building envelop components and heating ventilating and air conditioning (HVAC) equipment necessitates the examination of operational strategies for improvement in energy-efficient operation of buildings. Due to the ease of installation and increasing availability of electronic controllers, operational strategies that could be programmed are of particular interest. The Iowa Energy Center in the US has taken the initiative to conduct the necessary assessment of current HVAC technology and the commonly-used operational strategies for commercial and industrial buildings, as applied to the midwestern part of the country, with weather and energy cost data for Des Moines, Iowa. The first part of this study focused on the energy consumption and cost effectiveness of HVAC systems. The objectives of the second part is concerned with examination of various operational strategies, namely, night purge (NP), fan optimum start and stop (OSS), condenser water reset (CWR), and chilled water reset (CHWR) applied to order and newer-type commercial office buildings. The indoor air quality requirement are met and the latest applicable energy rates from local utility companies are used. The results show that, in general, NP is not an effective strategy in buildings with low thermal mass storage, OSS reduced fan energy, and CWR and CHWR could be effective and require chillers with multi-stage unloading characteristics. The most operationally efficient strategies are the combination of OSS, CWR, and CHWR for the older-type building, and OSS for the newer-type building. Economically, the most effective is the OSS strategy for the older-type building and the CHWR strategy for the newer-type building.(Author)

  15. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  16. Simulation and Efficient Measurements of Intensities for Complex Imaging Sequences

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Rasmussen, Morten Fischer; Stuart, Matthias Bo

    2014-01-01

    on the sequence to simulate both intensity and mechanical index (MI) according to FDA rules. A 3 MHz BK Medical 8820e convex array transducer is used with the SARUS scanner. An Onda HFL-0400 hydrophone and the Onda AIMS III system measures the pressure field for three imaging schemes: a fixed focus, single...

  17. An efficient similarity measure technique for medical image registration

    Indian Academy of Sciences (India)

    In this paper, an efficient similarity measure technique is proposed for medical image registration. The proposed approach is based on the Gerschgorin circles theorem. In this approach, image registration is carried out by considering Gerschgorin bounds of a covariance matrix of two compared images with normalized ...

  18. Measurements of TFTR D-T radiation shielding efficiency

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ascione, G.; Elwood, S.; Gilbert, J.; Ku, L.P.; Levine, J.; Rule, K.; Azziz, N.; Goldhagen, P.; Hajnal, F.

    1994-11-01

    Measurements of neutron and gamma dose-equivalents were performed in the Test Cell, at the outer Test Cell wall, in nearby work areas, and out to the nearest property lines at a distance of 180 m. Argon ionization chambers, moderated 3 He proportional counters, and fission chamber detectors were used to obtain measurements of neutron and gamma dose-equivalents per D-T neutron during individual TFTR discharges. These measured neutron and gamma D-T dose-equivalents per TFTR neutron characterize the effects of local variations in material density resulting from the complex asymmetric site geometry. The measured dose-equivalents per TFTR D-T neutron and the cumulative neutron production were used to determine that the planned annual TFTR neutron production of 1 x 10 21 D-T neutrons is consistent with the design objective of limiting the total dose-equivalent at the property line, from all radiation sources and pathways, to less than 10 mrem per year

  19. Selected Private Higher Educational Institutions in Metro Manila: A DEA Efficiency Measurement

    Science.gov (United States)

    de Guzman, Maria Corazon Gwendolyn N.; Cabana, Emilyn

    2009-01-01

    This paper measures the technical efficiency of 16 selected colleges and universities in Metro Manila, Philippines, using academic data for the SY 2001-2005. Using the data envelopment analysis (DEA), on average, schools posted 0.807 index score and need additional 19.3% efficiency growth to be efficient. Overall, there are top four efficient…

  20. Consumer’s Attitude Towards Investments in Residential Energy-Efficient Appliances: How End-User Choices Contribute to Change Future Energy Systems

    DEFF Research Database (Denmark)

    Baldini, Mattia; Trivella, Alessio; Wente, Jordan William Halverson

    2017-01-01

    conventional and environmentally friendly alternatives when purchasing new household electric appliances. This study employs empirical data from a survey conducted by the Danish Energy Agency to model the decision criteria behind Danish consumer investment in energy-efficient labeled appliances. The analysis...... uses logistic regression over a set of socioeconomic, demographic, and behavioral variables to predict purchase propensities. The findings are relevant for policy makers interested in targeting consumers in the appliance market, particularly for a relatively wealthy national context. The study...

  1. PSYCHOPHYSICAL MEASURES FOR EFFICIENT ERGONOMICS IN THE OFFICE

    Directory of Open Access Journals (Sweden)

    Ana-Cristina LESE

    2017-08-01

    Full Text Available In the working environment of the modern man, where the junction man-machine is a system that aims at achieving professional success, the ergonomic measures are increasingly promoted. These measures come after waves of complaints from the employees who often accuse psycho-physical fatigue. In this paper we will present a series of psychophysical techniques designed for those employees who work in an office. The examples are built on patterns existing in the physical exercise practice and mental theatre training used by some of the greatest teachers of theatre in the world. Alternating these types of physical and mental exercises, adapted for office work, can visibly improve the health of the employees

  2. Efficiency of Foreign Exchange Markets and Measures of Turbulence

    OpenAIRE

    Jacob A. Frenkel; Michael L. Mussa

    1980-01-01

    Since the move to generalized floating in1973, exchange rates between major currencies have displayed large fluctuations. This turbulence of foreign exchange rates is an important concern of government policy and its explanation is a challenge for theories of foreign exchange market behavior. In Section I of this paper, we document the extent of turbulence in foreign exchange markets by examining (i) the magnitude of short-run variations in exchange rates relative to other measures of economi...

  3. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  4. Measuring economy-wide energy efficiency performance: A parametric frontier approach

    International Nuclear Information System (INIS)

    Zhou, P.; Ang, B.W.; Zhou, D.Q.

    2012-01-01

    This paper proposes a parametric frontier approach to estimating economy-wide energy efficiency performance from a production efficiency point of view. It uses the Shephard energy distance function to define an energy efficiency index and adopts the stochastic frontier analysis technique to estimate the index. A case study of measuring the economy-wide energy efficiency performance of a sample of OECD countries using the proposed approach is presented. It is found that the proposed parametric frontier approach has higher discriminating power in energy efficiency performance measurement compared to its nonparametric frontier counterparts.

  5. Measuring the relative efficiency of Ilam hospitals using data envelopment analysis

    Directory of Open Access Journals (Sweden)

    Ehsan Fazeli

    2012-08-01

    Full Text Available Measuring the relative efficiency is one of the most important issues among hospitals in today's economy. These days, we hear that cost reduction is a necessity for survival of business owners and one primary to reduce the expenditures is to increase relative efficiency. The proposed study of this paper first uses output oriented data envelopment analysis (DEA to measure the relative efficiencies of nine hospitals. The proposed model uses four types of employee namely specialists, physicians, technicians and other staffs as input parameters. The model also uses the number of surgeries, hospitalized and radiography as the outputs of the proposed model. Since the implementation of DEA leads us to have more than one single efficient unit, we implement supper efficiency technique to measure the relative efficiency of efficient units.

  6. Implementation of energy efficiency measures by municipal utilities; Umsetzung von Energieeffizienzmassnahmen durch Stadtwerke

    Energy Technology Data Exchange (ETDEWEB)

    Horst, Juri; Droeschel, Barbara [Institut fuer ZukunftsEnergieSysteme (IZES), Saarbruecken (Germany)

    2012-04-15

    Local players have a very special role to fill in the implementation of the German federal government's ambitious energy efficiency goals. In the past the contributions made by municipal utilities in the way of special offers or measures to develop efficiency potentials were only modest. Moreover there were specific impediments that discouraged a significant competition-driven efficiency services market from developing. However, there are other instruments available that could encourage municipal utilities to implement efficiency goals. A recent research project has shown how standardised efficiency programmes can be used to tap into existing efficiency potentials at a sufficient level of intensity and with macroeconomic benefit.

  7. Efficiency measurement with a non-convex free disposal hull technology

    DEFF Research Database (Denmark)

    Fukuyama, Hirofumi; Hougaard, Jens Leth; Sekitani, Kazuyuki

    2016-01-01

    We investigate the basic monotonicity properties of least-distance (in)efficiency measures on the class of non-convex FDH (free disposable hull) technologies. We show that any known FDH least-distance measure violates strong monotonicity over the strongly (Pareto-Koopmans) efficient frontier. Tak....... Taking this result into account, we develop a new class of FDH least-distance measures that satisfy strong monotonicity and show that the developed (in)efficiency measurement framework has a natural profit interpretation.......We investigate the basic monotonicity properties of least-distance (in)efficiency measures on the class of non-convex FDH (free disposable hull) technologies. We show that any known FDH least-distance measure violates strong monotonicity over the strongly (Pareto-Koopmans) efficient frontier...

  8. Application of Data Envelopment Analysis to Measure Cost, Revenue and Profit Efficiency

    Directory of Open Access Journals (Sweden)

    Kristína Kočišová

    2014-09-01

    Full Text Available The literature analysing efficiency of financial institutions has enveloped rapidly over the last years. Most studies have focused on the input side analysing input technical and cost efficiency. Only few studies have examined the output side evaluating output technical and revenue efficiency. We know that both sides are relevant when evaluating efficiency of financial institutions. Therefore the primary purpose of this paper is to review a number of approaches for efficiency measurement. In particular, the concepts of cost, revenue and profit functions are discussed. We apply Data Envelopment Analysis (DEA to a sample of Slovak and Czech commercial banks during years 2009–2013 comparing the efficiencies by either minimizing cost or maximizing revenue and profit. The results showed that the level of average revenue efficiency was the highest and the average profit efficiency was the lowest one. As can be seen the Czech banks were more cost, revenue and profit efficient than Slovak ones during the whole analysed period.

  9. Inference from concave stochastic frontiers and the covariance of firm efficiency measures across firms

    International Nuclear Information System (INIS)

    Dashti, Imad

    2003-01-01

    This paper uses a Bayesian stochastic frontier model to obtain confidence intervals on firm efficiency measures of electric utilities rather than the point estimates reported in most previous studies. Results reveal that the stochastic frontier model yields imprecise measures of firm efficiency. However, the application produces much more precise inference on pairwise efficiency comparisons of firms due to a sometimes strong positive covariance of efficiency measures across firms. In addition, we examine the sensitivity to functional form by repeating the analysis for Cobb-Douglas, translog and Fourier frontiers, with and without imposing monotonicity and concavity

  10. Chapter 6: Residential Lighting Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Dimetrosky, Scott [Apex Analytics LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics LLC, Boulder, CO (United States)

    2015-02-01

    In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

  11. Energy efficiency measures for offshore oil and gas platforms

    DEFF Research Database (Denmark)

    Nguyen, Tuong-Van; Voldsund, Mari; Breuhaus, Peter

    2016-01-01

    . They include: (i) the installation of multiple pressure levels in production manifolds, (ii) the implementation of multiphaseexpanders, (iii) the promotion of energy and process integration, (iv) the limitation of gas recirculation around the compressors, (v) the exploitation of low-temperature heat from...... the gas cooling steps, (vi) the downsizing or replacement of the existing gas turbines, and (vii) the use of the waste heat from the powerplant. The present study builds on four actual cases located in the North and Norwegian Seas, which differ by the type of oil processed, operating conditions...... and strategies. The benefits and practical limitations of each measure are discussed based on thermodynamic, economic and environmental factors. Signiffcant energy savings and reductions in CO2-emissions are depicted, reaching up to 15-20 %. However, they strongly differ from one facility to another, which...

  12. Chained Bell Inequality Experiment with High-Efficiency Measurements

    Science.gov (United States)

    Tan, T. R.; Wan, Y.; Erickson, S.; Bierhorst, P.; Kienzler, D.; Glancy, S.; Knill, E.; Leibfried, D.; Wineland, D. J.

    2017-03-01

    We report correlation measurements on two 9Be+ ions that violate a chained Bell inequality obeyed by any local-realistic theory. The correlations can be modeled as derived from a mixture of a local-realistic probabilistic distribution and a distribution that violates the inequality. A statistical framework is formulated to quantify the local-realistic fraction allowable in the observed distribution without the fair-sampling or independent-and-identical-distributions assumptions. We exclude models of our experiment whose local-realistic fraction is above 0.327 at the 95% confidence level. This bound is significantly lower than 0.586, the minimum fraction derived from a perfect Clauser-Horne-Shimony-Holt inequality experiment. Furthermore, our data provide a device-independent certification of the deterministically created Bell states.

  13. Microscopic oxygen imaging based on fluorescein bleaching efficiency measurements

    DEFF Research Database (Denmark)

    Beutler, Martin; Heisterkamp, Ines M.; Piltz, Bastian

    2014-01-01

    by a charge-coupled-device (ccd) camera mounted on a fluorescence microscope allowed a pixelwise estimation of the ratio function in a microscopic image. Use of a microsensor and oxygen-consuming bacteria in a sample chamber enabled the calibration of the system for quantification of absolute oxygen......Photobleaching of the fluorophore fluorescein in an aqueous solution is dependent on the oxygen concentration. Therefore, the time-dependent bleaching behavior can be used to measure of dissolved oxygen concentrations. The method can be combined with epi-fluorescence microscopy. The molecular...... states of the fluorophore can be expressed by a three-state energy model. This leads to a set of differential equations which describe the photobleaching behavior of fluorescein. The numerical solution of these equations shows that in a conventional wide-field fluorescence microscope, the fluorescence...

  14. Developing measures for the evaluation of information flow efficiency in supply chains

    Directory of Open Access Journals (Sweden)

    Johanna A. Badenhorst

    2013-05-01

    Full Text Available Member organisations in a supply chain are dependent on each other to provide material, services and information to perform optimally in the supply chain. Efficient, unrestricted information flow is needed in supply chains to function properly. Information flow is thus an element of supply chain management that needs to be managed. Yet, no indication could be found in supply chain management literature of the measurement of information flow efficiency. Hence, the aim of this article is to explore the measurement of information flow efficiency in supply chain management (SCM and exploratively develop possible measures (indicators and associated metrics to measure the efficiency of information flow.In this research the theory of information and related concepts, the basic notions of information systems and the models of business performance measurement were explored. Based on information flow theory and information flow characteristics a research instrument was developed. It was used in a survey to seek inputs from supply chain managers as to the usefulness of characteristics as indicators and metrics for the measurement of information flow efficiency in a supply chain. The main contribution of the study is the development of a conceptual framework of indicators and metrics that may be used to evaluate the efficiency of information flows in supply chains. The results of this study can be used as a basis for further studies to validate the instrument for measuring information flow efficiency and to develop scales to actually measure information flow efficiency.

  15. Residential mobility and childhood leukemia.

    Science.gov (United States)

    Amoon, A T; Oksuzyan, S; Crespi, C M; Arah, O A; Cockburn, M; Vergara, X; Kheifets, L

    2018-07-01

    Studies of environmental exposures and childhood leukemia studies do not usually account for residential mobility. Yet, in addition to being a potential risk factor, mobility can induce selection bias, confounding, or measurement error in such studies. Using data collected for California Powerline Study (CAPS), we attempt to disentangle the effect of mobility. We analyzed data from a population-based case-control study of childhood leukemia using cases who were born in California and diagnosed between 1988 and 2008 and birth certificate controls. We used stratified logistic regression, case-only analysis, and propensity-score adjustments to assess predictors of residential mobility between birth and diagnosis, and account for potential confounding due to residential mobility. Children who moved tended to be older, lived in housing other than single-family homes, had younger mothers and fewer siblings, and were of lower socioeconomic status. Odds ratios for leukemia among non-movers living mobility, including dwelling type, increased odds ratios for leukemia to 2.61 (95% CI: 1.76-3.86) for living mobility of childhood leukemia cases varied by several sociodemographic characteristics, but not by the distance to the nearest power line or calculated magnetic fields. Mobility appears to be an unlikely explanation for the associations observed between power lines exposure and childhood leukemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Time-dependent efficiency measurements of polymer solar cells with dye additives: unexpected initial increase of efficiency

    Science.gov (United States)

    Bandaccari, Kyle J.; Chesmore, Grace E.; Bugaj, Mitchel; Valverde, Parisa Tajalli-Tehrani; Barber, Richard P.; McNelis, Brian J.

    2018-04-01

    We report the effects of the addition of two azo-dye additives on the time-dependent efficiency of polymer solar cells. Although the maximum efficiencies of devices containing different amounts of dye do not vary greatly over the selected concentration range, the time dependence results reveal a surprising initial increase in efficiency in some samples. We observe this effect to be correlated with a leakage current, although a specific mechanism is not yet identified. We also present the measured lifetimes of these solar cells, and find that variations in dye concentrations produce a small effect at most. Characterization of the bulk heterojunction layer (active layer) morphology using atomic-force microscope (AFM) imaging reveals reordering patterns which suggest that the primary effects of the dyes arise via structural, not absorptive, characteristics.

  17. The effect of merger and consolidation activities on the efficiency of electricity distribution regions in Turkey

    International Nuclear Information System (INIS)

    Çelen, Aydın

    2013-01-01

    In this study, we analyze the efficiency performances of Turkish electricity distribution companies throughout 2002 and 2009 in the stochastic frontier analysis (SFA) framework. Our more specific goal is to measure how the efficiency performances of the electricity distribution regions were affected by the mergers between distribution regions occurred in 2005. The results demonstrate that efficiencies of the companies serving to mostly the residential customers are higher than those of other companies. However, the positive impact of residential customers on the efficiencies decreased significantly following the mergers between electricity distribution companies. In contrast, the positive impact of higher customer density on efficiency also decreased, but insignificantly following the restructuring activities in the market in 2005. Our study also witnesses that the positive impact of the mergers on the efficiencies decreases as the proportion of sales to residential customers in regions increases. In contrast, the restructuring activities of 2005 increased equally the efficiencies of the companies serving in the regions with higher and lower customer densities. - Highlights: • We analyze efficiency performances of Turkish electricity distribution companies. • The efficiencies of companies serving to mostly residential customers are higher. • Positive impact of residential customers on the efficiencies dropped after mergers. • Positive impact of customer density also decreased, but insignificantly. • Positive impact of mergers on efficiency decreases as sales to residents increase

  18. Fitting methods for constructing energy-dependent efficiency curves and their application to ionization chamber measurements

    International Nuclear Information System (INIS)

    Svec, A.; Schrader, H.

    2002-01-01

    An ionization chamber without and with an iron liner (absorber) was calibrated by a set of radionuclide activity standards of the Physikalisch-Technische Bundesanstalt (PTB). The ionization chamber is used as a secondary standard measuring system for activity at the Slovak Institute of Metrology (SMU). Energy-dependent photon-efficiency curves were established for the ionization chamber in defined measurement geometry without and with the liner, and radionuclide efficiencies were calculated. Programmed calculation with an analytical efficiency function and a nonlinear regression algorithm of Microsoft (MS) Excel for fitting was used. Efficiencies from bremsstrahlung of pure beta-particle emitters were calibrated achieving a 10% accuracy level. Such efficiency components are added to obtain the total radionuclide efficiency of photon emitters after beta decay. The method yields differences of experimental and calculated radionuclide efficiencies for most of the photon-emitting radionuclides in the order of a few percent

  19. A method to identify energy efficiency measures for factory systems based on qualitative modeling

    CERN Document Server

    Krones, Manuela

    2017-01-01

    Manuela Krones develops a method that supports factory planners in generating energy-efficient planning solutions. The method provides qualitative description concepts for factory planning tasks and energy efficiency knowledge as well as an algorithm-based linkage between these measures and the respective planning tasks. Its application is guided by a procedure model which allows a general applicability in the manufacturing sector. The results contain energy efficiency measures that are suitable for a specific planning task and reveal the roles of various actors for the measures’ implementation. Contents Driving Concerns for and Barriers against Energy Efficiency Approaches to Increase Energy Efficiency in Factories Socio-Technical Description of Factory Planning Tasks Description of Energy Efficiency Measures Case Studies on Welding Processes and Logistics Systems Target Groups Lecturers and Students of Industrial Engineering, Production Engineering, Environmental Engineering, Mechanical Engineering Practi...

  20. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  1. Energy efficiency policies and measures in Norway: monitoring of energy efficiency in EU27, Norway and Croatia (ODYSSEE-MURE)

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Eva

    2009-09-15

    This report represents the national case study of Norway for the EIE-project 'Monitoring of Energy Demand Trends and Energy Efficiency in the EU - ODYSSEE-MURE'. It presents the recent energy efficiency trends in Norway on the basis of indicators extracted from the ODYSSEE database. Total energy consumption (not including energy as feedstock) has increased from 16.6 M toe (195 TWh) in 1990 to 19.2 M toe (226 TWh) in 2007 and has been relatively constant the last ten years. Energy consumption in manufacturing industry has increased by 10 % from 1990 to 2007, but is lower in 2007 than in 1998. Final energy use in households has increased from 3515 k toe (41 TWh) in 1990 to 3826 (45 TWh) in 2007. The climate corrected energy use has been at approximately 4000 k toe since the mid 1990s. It seems to be an interrupt in the increase of energy use in households, despite the growth of all common used drivers in this sector. Energy efficiency policies and measures implemented since 1990 have contributed to improve the efficiency by 13 %, or 0.7 % per year; this means that if these policies and measures would not have been implemented, the final energy consumption would have been 13 % higher in 2007 (or approximately 1.9 M toe or 22 TWh). (Author)

  2. Energy efficiency policies and measures in Norway 2006. Monitoring of energy efficiency in EU15 and Norway (Odyssee-Mure)

    International Nuclear Information System (INIS)

    Rosenberg, Eva; Espegren, Kari Aamodt

    2006-12-01

    This report represents the national case study of Norway for the EIE-project 'Monitoring of energy efficiency in EU-15 and Norway - ODYSSEE-MURE'. It presents the recent energy efficiency trends in Norway on the basis of indicators extracted from the ODYSSEE database. Total energy consumption (not including energy as feedstock) has increased from 192 TWh in 1990 to a present maximum of 219 TWh in 1999. From then it has been a slight decrease and in 2005 the final energy consumption was 215 TWh. Energy consumption in manufacturing industry has increased by 11 percent from 1990 to 2004, and in the period 1998-2004 it seems to be steadying at approximately 78 TWh. Final energy use in households has increased from 41 TWh in 1990 to a maximum of 46.6 TWh in 1996 and 2002. In 2005 44.1 TWh was used, which is almost the same as the consumption in 1994. It seems to be an interrupt in the increase of energy use in households, despite the growth of all common used drivers in this sector. Energy efficiency policies and measures implemented since 1990 have contributed to improve the efficiency by 10 percent, or 0.7 percent per year; this means that if these policies and measures would not have been implemented, the final energy consumption would have been 10 percent higher in 2004 (or approximately 19 TWh) (author) (ml)

  3. Energy efficiency measures in China: A three-stage DEA analysis

    Science.gov (United States)

    Cai, Yu; Xiong, Siqin; Ma, Xiaoming

    2017-04-01

    This paper measures energy efficiency of 30 regions in China during 2010-2014 by using the three-stage data envelopment analysis (DEA) model. The results indict that environmental factors and random error both have significant impacts on energy efficiency. After eliminating these influences, the results present that the energy efficiency in developed regions is almost higher than that in undeveloped or resource-rich regions and low scale technical efficiency is the main constraining factor in inefficient regions. Based on the efficiency characteristics, this paper divides all regions into four types and provide differential energy strategies.

  4. A robust AHP-DEA method for measuring the relative efficiency: An application of airport industry

    Directory of Open Access Journals (Sweden)

    Amin Foroughi

    2012-01-01

    Full Text Available Measuring the relative efficiency of similar units has been an important topic of research among many researchers. Data envelopment analysis has been one of the most important techniques for measuring the efficiency of different units. However, there are some limitations on using such technique and some people prefer to use other methods such as analytical hierarchy process to measure the relative efficiencies. Besides, uncertainty in the input data is another issue, which makes some misleading results. In this paper, we present an integrated robust DEA-AHP to measure the relative efficiency of similar units. The proposed model of this is believed to capable of presenting better results in terms of efficiency compared with exclusive usage of DEA or AHP. The implementation of the proposed model is demonstrated for a real-world case study of Airport industry and the results are analyzed.

  5. Apparatus and method for measuring single cell and sub-cellular photosynthetic efficiency

    Science.gov (United States)

    Davis, Ryan Wesley; Singh, Seema; Wu, Huawen

    2013-07-09

    Devices for measuring single cell changes in photosynthetic efficiency in algal aquaculture are disclosed that include a combination of modulated LED trans-illumination of different intensities with synchronized through objective laser illumination and confocal detection. Synchronization and intensity modulation of a dual illumination scheme were provided using a custom microcontroller for a laser beam block and constant current LED driver. Therefore, single whole cell photosynthetic efficiency, and subcellular (diffraction limited) photosynthetic efficiency measurement modes are permitted. Wide field rapid light scanning actinic illumination is provided for both by an intensity modulated 470 nm LED. For the whole cell photosynthetic efficiency measurement, the same LED provides saturating pulses for generating photosynthetic induction curves. For the subcellular photosynthetic efficiency measurement, a switched through objective 488 nm laser provides saturating pulses for generating photosynthetic induction curves. A second near IR LED is employed to generate dark adapted states in the system under study.

  6. Does a carbon tax make sense in countries with still a high potential for energy efficiency? Comparison between the reducing-emissions effects of carbon tax and energy efficiency measures in the Chilean case

    International Nuclear Information System (INIS)

    Vera, Sonia; Sauma, Enzo

    2015-01-01

    Many countries have not yet successfully decoupled their growth and their energy consumption. Moreover, power production frequently entails a number of negative externalities, like greenhouse gas emissions from thermo electrical units. This situation has highlighted the need for countries to move towards sustainable economic growth. Accordingly, many countries have proposed and established measures to decrease their carbon emissions. In this line, the Chilean government has just passed a carbon tax of $5/Ton CO 2 e. In this work, we compare the effects on reducing CO 2 emissions of this carbon tax and of some energy efficiency measures in the power sector. The results obtained indicate that the imposed carbon tax will produce an expected annual reduction in CO 2 emissions of 1% with respect to the estimated baseline during the 2014–2024 period. However, this reduction will be accompanied by an expected 3.4% increase in the marginal cost of power production on the main Chilean power system. In contrast, the introduction of some energy efficiency measures, aimed to reduce 2% of the power demand of the residential sector, could achieve larger reductions in CO 2 emissions, while simultaneously decreasing energy price. - Highlights: • We estimate CO 2 emission reductions due to a carbon tax and EE measures in Chile. • We simulate the main Chilean power system with diverse levels of carbon tax and EE. • Energy efficiency measures could achieve better results than carbon tax in Chile. • The carbon tax imposed in Chile reduces CO 2 emissions in 1% in the 2014–2024 period. • The carbon tax imposed in Chile increases system marginal cost in 3.4% in 2014–2024

  7. Factor Structure, Reliability and Measurement Invariance of the Alberta Context Tool and the Conceptual Research Utilization Scale, for German Residential Long Term Care

    Science.gov (United States)

    Hoben, Matthias; Estabrooks, Carole A.; Squires, Janet E.; Behrens, Johann

    2016-01-01

    We translated the Canadian residential long term care versions of the Alberta Context Tool (ACT) and the Conceptual Research Utilization (CRU) Scale into German, to study the association between organizational context factors and research utilization in German nursing homes. The rigorous translation process was based on best practice guidelines for tool translation, and we previously published methods and results of this process in two papers. Both instruments are self-report questionnaires used with care providers working in nursing homes. The aim of this study was to assess the factor structure, reliability, and measurement invariance (MI) between care provider groups responding to these instruments. In a stratified random sample of 38 nursing homes in one German region (Metropolregion Rhein-Neckar), we collected questionnaires from 273 care aides, 196 regulated nurses, 152 allied health providers, 6 quality improvement specialists, 129 clinical leaders, and 65 nursing students. The factor structure was assessed using confirmatory factor models. The first model included all 10 ACT concepts. We also decided a priori to run two separate models for the scale-based and the count-based ACT concepts as suggested by the instrument developers. The fourth model included the five CRU Scale items. Reliability scores were calculated based on the parameters of the best-fitting factor models. Multiple-group confirmatory factor models were used to assess MI between provider groups. Rather than the hypothesized ten-factor structure of the ACT, confirmatory factor models suggested 13 factors. The one-factor solution of the CRU Scale was confirmed. The reliability was acceptable (>0.7 in the entire sample and in all provider groups) for 10 of 13 ACT concepts, and high (0.90–0.96) for the CRU Scale. We could demonstrate partial strong MI for both ACT models and partial strict MI for the CRU Scale. Our results suggest that the scores of the German ACT and the CRU Scale for nursing

  8. Nature of unresolved complex mixture in size-distributed emissions from residential wood combustion as measured by thermal desorption-gas chromatography-mass spectrometry

    Science.gov (United States)

    Hays, Michael D.; Smith, N. Dean; Dong, Yuanji

    2004-08-01

    Unresolved complex mixture (UCM) is an analytical artifact of gas chromatographs of combustion source-related fine aerosol extracts. In this study the UCM is examined in size-resolved fine aerosol emissions from residential wood combustion. The aerosols are sorted by size in an electrical low-pressure impactor (ELPI) and subsequently analyzed by thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS). A semiquantitative system for predicting the branched alkane, cycloalkane, alkylbenzene, C3-, C4-, C5-alkylbenzene, methylnaphthalene, C3-, C4-, C5-alkylnaphthalene, methylphenanthrene C2-, C3-alkylphenanthrene, and dibenzothiophene concentrations in the UCM is introduced. Analysis by TD/GS/MS detects UCM on each ELPI stage for all six combustion tests. The UCM baseline among the different fuel types is variable. In particular, the UCM of Pseudotsuga sp. is enriched in later-eluting compounds of lower volatility. A high level of reproducibility is achieved in determining UCM areas. UCM fractions (UCM ion area/total extracted ion chromatograph area) by individual ELPI stage return a mean relative standard deviation of 19.1% over the entire combustion test set, indicating a highly consistent UCM fraction across the ELPI size boundaries. Among the molecular ions investigated, branched alkane (m/z 57) and dibenzothiophene (m/z 212 and 226) constituents are most abundant in UCM emissions from RWC, collectively accounting for 64-95% of the targeted chemical species. The total UCM emissions span 446-756 mg/kg of dry biomass burned and correspond to an upper limit of 7.1% of the PM2.5 mass. The UCM emissions are primarily accumulation mode (0.1 μm ≤ aerodynamic diameter (da) ≤ 1 μm), with a geometric mean diameter (dg) range of 120.3-518.4 nm. UCM in PM2.5 is chemically asymmetric (shifted to finer da), typically clustering at da ≤ 1 μm. Measurable shifts in dg and changes in distribution widths (σg) on an intratest basis suggest that the particle density

  9. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  10. Review of policies and measures for energy efficiency in industry sector

    International Nuclear Information System (INIS)

    Tanaka, Kanako

    2011-01-01

    Energy efficiency in industry plays key roles in improving energy security, environmental sustainability and economic performance. It is particularly important in strategies to mitigate climate change. The evidence of great potential for cost-effective efficiency-derived reductions in industrial energy use and greenhouse gas (GHG) emissions have prompted governments to implement numerous policies and measures aimed at improving their manufacturing industries' energy efficiency. What can be learned from these many and varied initiatives? This paper provides foundation for policy analysis for enhancing energy efficiency and conservation in industry, by surveying more than 300 policies, encompassing about 570 measures, implemented by governments in IEA countries, Brazil, China, India, Mexico, Russia and South Africa. It outlines the measures' main features, their incidence of use, and their connections with specific technical actions and key stakeholders (i.e., how and where measures affect the energy efficiency of industry). It also examines the key features underlying the measures' success: (1) potential to reduce energy use and CO 2 emissions cost-efficiently; (2) ease of policy development, execution and assessment and (3) ancillary societal effects. - Highlights: → Provides foundation for policy analysis for energy efficiency in industry. → Surveys more than 300 policies and their trends, of mainly IEA countries. → Outlines measures' features, incidence of use, technical actions and stakeholders. → Examines the key features underlying the measures' success.

  11. SHORT COMMUNICATION: Status of Physical Fitness Index (PFI % and Anthropometric Parameters in Residential School Children Compared to Nonresidential School Children

    Directory of Open Access Journals (Sweden)

    Jyoti P Khodnapur

    2012-07-01

    Full Text Available Background: Physical fitness is the prime criterion for survival, to achieve any goal and to lead a healthy life. Effect of exercise to have a good physical fitness is well known since ancient Vedas. Physical fitness can be recorded by cardiopulmonary efficiency test like Physical Fitness Index (PFI % which is a powerful indicator of cardiopulmonary efficiency. Regular exercise increases PFI by increasing oxygen consumption. Residential school children are exposed to regular exercise and nutritious food under the guidance. Aims and Objectives: Our study is aimed to compare the physical fitness index status and anthropometric parameters in Residential Sainik (n=100 school children compared to Non-Residential (n=100 school children (aged between 12-16 years of Bijapur. Material and Methods: PFI was measured by Harvard Step Test [1]. TheAnthropometrical parameters like Height (cms, Weight (Kg, Body Surface Area (BSA in sq.mts, Body Mass Index (BMI in Kg/m2, Mid Arm Circumference (cms, Chest Circumference (cms and Abdominal Circumference (cms were recorded. Results: Mean score of PFI(%, Height(cms, Weight(Kg, BSA(sq.mts, BMI(Kg/m2, Mid Arm Circumference(cms, Chest Circumference (cms and Abdominal Circumference (cms were significantly higher (p=0.000 in Residential school children compared to Non Residential school children. In conclusion regular exercise and nutritious diet under the guidance increases the physical fitness and growth in growing children.

  12. Closing the Energy Efficiency Gap: A study linking demographics with barriers to adopting energy efficiency measures in the home

    International Nuclear Information System (INIS)

    Pelenur, Marcos J.; Cruickshank, Heather J.

    2012-01-01

    This paper presents a study which linked demographic variables with barriers affecting the adoption of domestic energy efficiency measures in large UK cities. The aim was to better understand the ‘Energy Efficiency Gap’ and improve the effectiveness of future energy efficiency initiatives. The data for this study was collected from 198 general population interviews (1.5–10 min) carried out across multiple locations in Manchester and Cardiff. The demographic variables were statistically linked to the identified barriers using a modified chi-square test of association (first order Rao–Scott corrected to compensate for multiple response data), and the effect size was estimated with an odds-ratio test. The results revealed that strong associations exist between demographics and barriers, specifically for the following variables: sex; marital status; education level; type of dwelling; number of occupants in household; residence (rent/own); and location (Manchester/Cardiff). The results and recommendations were aimed at city policy makers, local councils, and members of the construction/retrofit industry who are all working to improve the energy efficiency of the domestic built environment. -- Highlights: ► 7 demographic variables linked to 8 barriers to adopting energy efficiency measures. ► A modified chi-square test for association was used (first order Rao–Scott corrected). ► Results revealed strong associations between most of the demographics and barriers. ► Data was collected from 198 interviews in the UK cities of Manchester and Cardiff. ► Specific recommendations are presented for regional policy makers and industry.

  13. Adoption of energy efficiency measures in Swedish detached houses - perception of homeowners

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna [Ecotechnology, Mid Sweden Univ., Oestersund (Sweden)

    2009-07-01

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The results of a questionnaire surveying of 3000 randomly selected homeowners during the summer of 2008 showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Hence, economic incentives could be used to increase the adoption of such measures. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt energy efficiency measures

  14. Use Conditions and Efficiency Measurements of DC Power Optimizers for Photovoltaic Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deline, C.; MacAlpine, S.

    2013-10-01

    No consensus standard exists for estimating annual conversion efficiency of DC-DC converters or power optimizers in photovoltaic (PV) applications. The performance benefits of PV power electronics including per-panel DC-DC converters depend in large part on the operating conditions of the PV system, along with the performance characteristics of the power optimizer itself. This work presents acase study of three system configurations that take advantage of the capabilities of DC power optimizers. Measured conversion efficiencies of DC-DC converters are applied to these scenarios to determine the annual weighted operating efficiency. A simplified general method of reporting weighted efficiency is given, based on the California Energy Commission's CEC efficiency rating and severalinput / output voltage ratios. Efficiency measurements of commercial power optimizer products are presented using the new performance metric, along with a description of the limitations of the approach.

  15. Calorimetric Measurement for Internal Conversion Efficiency of Photovoltaic Cells/Modules Based on Electrical Substitution Method

    Science.gov (United States)

    Saito, Terubumi; Tatsuta, Muneaki; Abe, Yamato; Takesawa, Minato

    2018-02-01

    We have succeeded in the direct measurement for solar cell/module internal conversion efficiency based on a calorimetric method or electrical substitution method by which the absorbed radiant power is determined by replacing the heat absorbed in the cell/module with the electrical power. The technique is advantageous in that the reflectance and transmittance measurements, which are required in the conventional methods, are not necessary. Also, the internal quantum efficiency can be derived from conversion efficiencies by using the average photon energy. Agreements of the measured data with the values estimated from the nominal values support the validity of this technique.

  16. Propeller efficiency at full scale : measurement system and mathematical model design

    NARCIS (Netherlands)

    Muntean, T.V.

    2012-01-01

    What is propeller efficiency at full scale? This question is asked equally by ship operators and by propeller and propulsion system manufacturers. The question reflects the need to measure propeller efficiency at full physical scale and during regular operation of the vessel. The question has a

  17. Tailoring cross-sectional energy-efficiency measures to target groups in industry

    NARCIS (Netherlands)

    Wohlfarth, Katharina; Eichhammer, Wolfgang; Schlomann, Barbara; Worrell, Ernst

    2018-01-01

    The improvement of energy efficiency in industrial companies plays a crucial role for the energy transition. Although significant economic potentials have been identified, the concerned actors are still struggling to realize them fully. To support the implementation of energy efficiency measures by

  18. Measurement of the neutron detection efficiency of a 80% absorber-20% scintillating fibers calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Anelli, M.; Bertolucci, S. [Laboratori Nazionali di Frascati dell' INFN, Via E.Fermi 40, I-00044 Frascati (Italy); Bini, C., E-mail: cesare.bini@roma1.infn.i [Dipartimento di Fisica, Sapienza Universita di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); INFN Sezione di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); Branchini, P. [INFN Sezione di Roma Tre, Via della Vasca Navale, 84 I-00146 Roma (Italy); Corradi, G.; Curceanu, C. [Laboratori Nazionali di Frascati dell' INFN, Via E.Fermi 40, I-00044 Frascati (Italy); De Zorzi, G.; Di Domenico, A. [Dipartimento di Fisica, Sapienza Universita di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); INFN Sezione di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); Di Micco, B. [Dipartimento di Fisica dell' Universita ' Roma Tre' , Via della Vasca Navale, 84 I-00146 Roma (Italy); INFN Sezione di Roma Tre, Via della Vasca Navale, 84 I-00146 Roma (Italy); Ferrari, A. [Institute of Safety Research and Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, PF 510119, 01314 Dresden (Germany); Fiore, S. [Dipartimento di Fisica, Sapienza Universita di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); INFN Sezione di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); Gauzzi, P., E-mail: paolo.gauzzi@roma1.infn.i [Dipartimento di Fisica, Sapienza Universita di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); INFN Sezione di Roma, P.le A.Moro, 2 I-00185 Roma (Italy); Giovannella, S.; Happacher, F. [Laboratori Nazionali di Frascati dell' INFN, Via E.Fermi 40, I-00044 Frascati (Italy); Iliescu, M. [Laboratori Nazionali di Frascati dell' INFN, Via E.Fermi 40, I-00044 Frascati (Italy); ' Horia Hulubei' National Institute of Physics and Nuclear Engineering, Str. Atomistilor no. 407, P.O. Box MG-6 Bucharest-Magurele (Romania); Luca, A.; Martini, M.; Miscetti, S. [Laboratori Nazionali di Frascati dell' INFN, Via E.Fermi 40, I-00044 Frascati (Italy)

    2011-01-21

    The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.

  19. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  20. Electricity demand for South Korean residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Sa' ad, Suleiman [Surrey Energy Economics Centre (SEEC), Department of Economics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-12-15

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

  1. Field Measurements of Heating Efficiency of Electric Forced-Air Furnaces in Six Manufactured Homes.

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Bob; Palmiter, Larry S.; Siegel, Jeff

    1994-07-26

    This report presents the results of field measurements of heating efficiency for six manufactured homes in the Pacific Northwest heated with electric forced-air systems. This is the first in a series of regional and national efforts to measure in detail the heating efficiency of manufactured homes. Only six homes were included in this study because of budgetary constraints; therefore this is not a representative sample. These investigations do provide some useful information on the heating efficiency of these homes. Useful comparisons can be drawn between these study homes and site-built heating efficiencies measured with a similar protocol. The protocol used to test these homes is very similar to another Ecotope protocol used in the study conducted in 1992 and 1993 for the Bonneville Power Administration to test the heating efficiency of 24 homes. This protocol combined real-time power measurements of furnace energy usage with energy usage during co-heat periods. Accessory data such as house and duct tightness measurements and tracer gas measurements were used to describe these homes and their heating system efficiency. Ensuring that manufactured housing is constructed in an energy and resource efficient manner is of increasing concern to manufactured home builders and consumers. No comparable work has been done to measure the heating system efficiency of MCS manufactured homes, although some co-heat tests have been performed on manufactured homes heated with natural gas to validate HUD thermal standards. It is expected that later in 1994 more research of this kind will be conducted, and perhaps a less costly and less time-consuming method for testing efficiencies will be develops.

  2. Measuring of the efficiency of bank branches on the basis of DEA approach

    OpenAIRE

    Korchahin, A.; Zhukau, A.

    2010-01-01

    The problem of the measuring of efficiency of bank branches in a bank strategic planning is considered. The Data Envelopment Analysis (DEA) is employed as a managerial tool to evaluate performance of network of bank branches.

  3. Reuter Centrifugal Air Sampler: Measurement of Effective Airflow Rate and Collection Efficiency

    OpenAIRE

    Macher, J. M.; First, M. W.

    1983-01-01

    Incorrect calculation of effective air sampling rate and disregard of differences in collection efficiency among samplers can lead to false conclusions about the usefulness of samplers for measuring concentrations of airborne microorganisms.

  4. Exploring the Relationship between Conduct Disorder and Residential Treatment Outcomes

    Science.gov (United States)

    Shabat, Julia Cathcart; Lyons, John S.; Martinovich, Zoran

    2008-01-01

    We examined the differential outcomes in residential treatment for youths with conduct disorder (CD)--with special attention paid to interactions with age and gender--in a sample of children and adolescents in 50 residential treatment centers and group homes across Illinois. Multi-disciplinary teams rated youths ages 6-20 (N = 457) on measures of…

  5. Effect of Organizational Climate on Youth Outcomes in Residential Treatment

    Science.gov (United States)

    Jordan, Neil; Leon, Scott C.; Epstein, Richard A.; Durkin, Elizabeth; Helgerson, Jena; Lakin-Starr, Brittany L.

    2009-01-01

    This study examined the association between organizational climate and changes in internalizing and externalizing behavior for youth in residential treatment centers (RTCs). The sample included 407 youth and 349 front-line residential treatment staff from 17 RTCs in Illinois. Youth behavior was measured using the Child Functional Assessment Rating…

  6. Extracting the emitter orientation in organic light-emitting diodes from external quantum efficiency measurements

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Tobias D., E-mail: Tobias.Schmidt@physik.uni-augsburg.de; Reichardt, Lukas J.; Wehrmeister, Sebastian; Scholz, Bert J.; Mayr, Christian; Brütting, Wolfgang, E-mail: Wolfgang.Bruetting@physik.uni-augsburg.de [Institute of Physics, University of Augsburg, 86135 Augsburg (Germany); Rausch, Andreas F.; Wehlus, Thomas; Reusch, Thilo C. G. [OSRAM OLED GmbH, Wernerwerkstrasse 2, 93049 Regensburg (Germany); Ciarnáin, Rossá Mac; Danz, Norbert [Fraunhofer Institute for Applied Optics and Precision Engineering, 07745 Jena (Germany)

    2014-07-28

    Emitter orientation will play a major role in future applications of organic light-emitting diodes due to its strong impact on the efficiency of the devices. Up to now, determining the orientation of transition dipole moments required elaborate angular-dependent measurements of the light emission pattern. In this paper, we present a simplified and straightforward method to extract the emitter orientation from external quantum efficiency measurements. We demonstrate the validity of the method on three different dye-doped emitting systems.

  7. Energy Efficiency Under Alternative Carbon Policies. Incentives, Measurement, and Interregional Effects

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, Daniel C. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Boyd, Erin [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-08-28

    In this report, we examine and compare how tradable mass-based polices and tradable rate-based policies create different incentives for energy efficiency investments. Through a generalized demonstration and set of examples, we show that as a result of the output subsidy they create, traditional rate-based policies, those that do not credit energy savings from efficiency measures, reduce the incentive for investment in energy efficiency measures relative to an optimally designed mass-based policy or equivalent carbon tax. We then show that this reduced incentive can be partially addressed by modifying the rate-based policy such that electricity savings from energy efficiency measures are treated as a source of zero-carbon generation within the framework of the standard, or equivalently, by assigning avoided emissions credit to the electricity savings at the rate of the intensity target. These approaches result in an extension of the output subsidy to efficiency measures and eliminate the distortion between supply-side and demand-side options for GHG emissions reduction. However, these approaches do not address electricity price distortions resulting from the output subsidy that also impact the value of efficiency measures. Next, we assess alternative approaches for crediting energy efficiency savings within the framework of a rate-based policy. Finally, we identify a number of challenges that arise in implementing a rate-based policy with efficiency crediting, including the requirement to develop robust estimates of electricity savings in order to assess compliance, and the requirement to track the regionality of the generation impacts of efficiency measures to account for their interstate effects.

  8. Measuring and Benchmarking Technical Efficiency of Public Hospitals in Tianjin, China

    Science.gov (United States)

    Li, Hao; Dong, Siping

    2015-01-01

    China has long been stuck in applying traditional data envelopment analysis (DEA) models to measure technical efficiency of public hospitals without bias correction of efficiency scores. In this article, we have introduced the Bootstrap-DEA approach from the international literature to analyze the technical efficiency of public hospitals in Tianjin (China) and tried to improve the application of this method for benchmarking and inter-organizational learning. It is found that the bias corrected efficiency scores of Bootstrap-DEA differ significantly from those of the traditional Banker, Charnes, and Cooper (BCC) model, which means that Chinese researchers need to update their DEA models for more scientific calculation of hospital efficiency scores. Our research has helped shorten the gap between China and the international world in relative efficiency measurement and improvement of hospitals. It is suggested that Bootstrap-DEA be widely applied into afterward research to measure relative efficiency and productivity of Chinese hospitals so as to better serve for efficiency improvement and related decision making. PMID:26396090

  9. Evaluating energy efficiency for airlines: An application of Virtual Frontier Dynamic Slacks Based Measure

    International Nuclear Information System (INIS)

    Cui, Qiang; Li, Ye; Yu, Chen-lu; Wei, Yi-Ming

    2016-01-01

    The fast growing Revenue Passenger Kilometers and the relatively lagged energy supply of aviation industry impels the airlines to improve energy efficiency. In this paper, we focus on evaluating and analyzing influencing factors for airline energy efficiency. Number of employees and aviation kerosene are chosen as the inputs. Revenue Ton Kilometers, Revenue Passenger Kilometers and total business income are the outputs. Capital stock is selected as the dynamic factor. A new model, Virtual Frontier Dynamic Slacks Based Measure, is proposed to calculate the energy efficiencies of 21 airlines from 2008 to 2012. We verify two important properties to manifest the advantages of the new model. Then a regression is run to analyze the influencing factors of airline energy efficiency. The main findings are: 1. The overall energy efficiency of Malaysia Airlines is the highest during 2008–2012.2. Per capita Gross Domestic Product, the average service age of fleet size and average haul distance have significant impacts on the efficiency score. 3. The difference between full-service carriers and low-cost carriers has no significant effects on airline energy efficiency. - Highlights: • A Virtual Frontier Dynamic Slacks Based Measure is developed. • 21 airlines' energy efficiencies are evaluated. • Malaysia Airlines has the highest overall energy efficiency. • Three explanatory variables have significant impacts.

  10. A modified Wheeler cap method for radiation efficiency measurement of balanced electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2010-01-01

    , but not for balanced antennas like loops or dipoles. In this paper, a modified Wheeler cap method is proposed for the radiation efficiency measurement of balanced electrically small antennas and a three-port network model of the Wheeler cap measurement is introduced. The advantage of the modified method...... is that it is wideband, thus does not require any balun, and both the antenna input impedance and radiation efficiency can be obtained. An electrically small loop antenna and a wideband dipole were simulated and measured according to the proposed method and the results of measurements and simulations are presented...

  11. Family ties and residential locations

    NARCIS (Netherlands)

    Mulder, C.H.; Cooke, T.J.

    2009-01-01

    In this paper, and in the Special Issue it introduces, the focus is on the role of family ties in residential location choice and, conversely, the role of residential locations in maintaining family ties. Not only do events in the nuclear family trigger residential relocations, but nearby family

  12. Methodology to characterize a residential building stock using a bottom-up approach: a case study applied to Belgium

    Directory of Open Access Journals (Sweden)

    Samuel Gendebien

    2014-06-01

    Full Text Available In the last ten years, the development and implementation of measures to mitigate climate change have become of major importance. In Europe, the residential sector accounts for 27% of the final energy consumption [1], and therefore contributes significantly to CO2 emissions. Roadmaps towards energy-efficient buildings have been proposed [2]. In such a context, the detailed characterization of residential building stocks in terms of age, type of construction, insulation level, energy vector, and of evolution prospects appears to be a useful contribution to the assessment of the impact of implementation of energy policies. In this work, a methodology to develop a tree-structure characterizing a residential building stock is presented in the frame of a bottom-up approach that aims to model and simulate domestic energy use. The methodology is applied to the Belgian case for the current situation and up to 2030 horizon. The potential applications of the developed tool are outlined.

  13. GREEN RETROFITTING RESIDENTIAL BUILDINGS

    Science.gov (United States)

    When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...

  14. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    International Nuclear Information System (INIS)

    Brown, E.J.; Ballinger, C.T.; Burger, S.R.; Charache, G.W.; Danielson, L.R.; DePoy, D.M.; Donovan, T.J.; LoCascio, M.

    2000-01-01

    The performance of a 1 cm 2 thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage

  15. An evaluation of accounting-based finding costs as efficiency measures for oil and gas exploration

    International Nuclear Information System (INIS)

    Boynton, C.E. IV; Boone, J.P.

    1994-08-01

    The authors have operationalized firm-specific exploration efficiency as the difference between a firm-specific intercept estimated in a fixed-effects panel data Cobb-Douglas production frontier model and the maximum firm-specific intercept estimated in that model. The production model was estimated during two different time periods, 1982--1985 and 1989--1992, allowing efficiency to vary intertemporally. This efficiency estimate served as a benchmark against which they compared various measures of inverse finding costs. They assumed that the degree of association with an efficiency benchmark is an important attribute of any finding cost measure and that, further, the degree of association may be used as a metric for choosing between alternative finding cost measures. Accordingly, they evaluated the cross-sectional statistical association between estimated efficiency and alternative inverse finding cost measures. They discovered that the inverse finding cost measure that exhibited the strongest association with efficiency during the two time periods was a three-year moving-average finding cost which included exploration plus development expenditures as costs and reserve extensions and additions plus revisions as the units added

  16. An evaluation of accounting-based finding costs as efficiency measures for oil and gas exploration

    Energy Technology Data Exchange (ETDEWEB)

    Boynton, C.E. IV; Boone, J.P.

    1994-08-01

    The authors have operationalized firm-specific exploration efficiency as the difference between a firm-specific intercept estimated in a fixed-effects panel data Cobb-Douglas production frontier model and the maximum firm-specific intercept estimated in that model. The production model was estimated during two different time periods, 1982--1985 and 1989--1992, allowing efficiency to vary intertemporally. This efficiency estimate served as a benchmark against which they compared various measures of inverse finding costs. They assumed that the degree of association with an efficiency benchmark is an important attribute of any finding cost measure and that, further, the degree of association may be used as a metric for choosing between alternative finding cost measures. Accordingly, they evaluated the cross-sectional statistical association between estimated efficiency and alternative inverse finding cost measures. They discovered that the inverse finding cost measure that exhibited the strongest association with efficiency during the two time periods was a three-year moving-average finding cost which included exploration plus development expenditures as costs and reserve extensions and additions plus revisions as the units added.

  17. The Relationship between Quality Measurement and Efficiency Improvement in Health Care Systems

    OpenAIRE

    Gilbert Roland; Dr. Jane Marry Gill

    2017-01-01

    Quality measurement in health care organisation is most often considered as measures for cost-saving and error reduction in the clinical procedures. The concept of quality measurement in health care organisations is the analysis of effectiveness and accuracy in procedures for patients’ diagnosis and treatment. This study aimed to find the relationship between quality measurement and efficiency improvements in the healthcare sector of Mauritius. This was executed by using mixed methodological ...

  18. Integration of fuel cells into residential buildings

    International Nuclear Information System (INIS)

    Bell, J.M.; Entchev, E.; Gusdorf, J.; Szadkowski, F.; Swinton, M.; Kalbfleisch, W.; Marchand, R.

    2004-01-01

    Integration of small combined heat and power systems (CHP) into residential buildings is challenging as the loads are small, the load diversity is limited and there are a number of unresolved issues concerning sizing, control, peak loads, emergency operation, grid connection and export, etc. Natural Resources Canada has undertaken an initiative to investigate and develop techniques for the integration of small CHP systems into residential buildings using a highly instrumented house modified to allow quick installation and thorough monitoring of CHP integration techniques as well determining the performance of the CHP systems themselves when operating in a house. The first CHP system installed was a Stirling engine residential CHP system. It was used to examine the completeness of the CHP modifications to the house, to evaluate various building integration techniques and to measure the performance of the CHP system itself. The testing demonstrated the modified house to be an excellent facility for the development of CHP building integration techniques and the testing of residential CHP systems. The Stirling engine CHP system was found to operate well and produce meaningful input to the house. A second system (residential fuel cell) is presently being installed and building integration techniques and the performance of the fuel cell will be tested over the coming year. (author)

  19. Residential Energy Efficiency Potential: South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by South Carolina single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  20. Residential Energy Efficiency Potential: South Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by South Dakota single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  1. Residential Energy Efficiency Potential: West Virginia

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-27

    Energy used by West Virginia single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  2. Residential Energy Efficiency Potential: New York

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by New York single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  3. Residential Energy Efficiency Potential: New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by New Mexico single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  4. Residential Energy Efficiency Potential: North Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by North Dakota single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  5. Residential Energy Efficiency Potential: New Jersey

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by New Jersey single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  6. Residential Energy Efficiency Potential: New Hampshire

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-16

    Energy used by New Hampshire single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  7. Residential Energy Efficiency Potential: North Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by North Carolina single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  8. Residential Energy Efficiency Potential: Rhode Island

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Rhode Island single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  9. The technology gap and efficiency measure in WEC countries: Application of the hybrid meta frontier model

    International Nuclear Information System (INIS)

    Chiu, Yung-Ho; Lee, Jen-Hui; Lu, Ching-Cheng; Shyu, Ming-Kuang; Luo, Zhengying

    2012-01-01

    This study develops the hybrid meta frontier DEA model for which inputs are distinguished into radial inputs that change proportionally and non-radial inputs that change non-proportionally, in order to measure the technical efficiency and technology gap ratios (TGR) of four different regions: Asia, Africa, America, and Europe. This paper selects 87 countries that are members of the World Energy Council from 2005 to 2007. The input variables are industry and population, while the output variances are gross domestic product (GDP) and the amount of fossil-fuel CO 2 emissions. The result shows that countries’ efficiency ranking among their own region presents more implied volatility. In view of the Technology Gap Ratio, Europe is the most efficient of any region, but during the same period, Asia has a lower efficiency than other regions. Finally, regions with higher industry (or GDP) might not have higher efficiency from 2005 to 2007. And higher CO 2 emissions or population also might not mean lower efficiency for other regions. In addition, Brazil is not OECD member, but it is higher efficiency than other OECD members in emerging countries case. OECD countries are better efficiency than non-OECD countries and Europe is higher than Asia to control CO 2 emissions. If non-OECD countries or Asia countries could reach the best efficiency score, they should try to control CO 2 emissions. - Highlights: ► The new meta frontier Model for evaluating the efficiency and technology gap ratios. ► Higher CO 2 emissions might not lower efficiency than any other regions, like Europe. ► Asia’s output and CO 2 emissions simultaneously increased and lower of its efficiency. ► Non-OECD or Asia countries should control CO 2 emissions to reach best efficiency score.

  10. Integrated evaluation of radiative heating systems for residential buildings

    International Nuclear Information System (INIS)

    Anastaselos, Dimitrios; Theodoridou, Ifigeneia; Papadopoulos, Agis M.; Hegger, Manfred

    2011-01-01

    Based on the need to reduce CO 2 emissions and minimize energy dependency, the EU Member States have set ambitious energy policies goals and have developed respective, specific regulations, in order to improve the energy performance of the building sector. Thus, specific measures regarding the buildings' envelope, the use of efficient HVAC technologies and the integration of renewable energy systems are being constantly studied and promoted. The effective combination of these three main aspects will consequently result in maximum energy efficiency. Germany has played a key role in this development, with intensive work focusing in the improvement of the energy behaviour of the residential building stock. In this paper, the use of radiative heating systems placing special emphasis on infrared is being studied as part of the energy renovation of residential buildings from the 1970's. This is done by applying an integrated assessment model to evaluate specific interventions regarding the improvement of the energy behaviour of the buildings' envelope and the use of radiative heating systems, based on a thorough Life Cycle Analysis according to criteria of energy, economic and environmental performance, as well as thermal comfort. -- Highlights: → Assessment of energy, economic and environmental performance of heating systems. → Life Cycle Analysis in combination with the quality of thermal comfort. → Effectiveness of interventions in already partially insulated buildings.

  11. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  12. Field Measurement and Evaluation of the Passive and Active Solar Heating Systems for Residential Building Based on the Qinghai-Tibetan Plateau Case

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2017-10-01

    Full Text Available Passive and active solar heating systems have drawn much attention and are widely used in residence buildings in the Qinghai-Tibetan plateau due to its high radiation intensity. In fact, there is still lack of quantitative evaluation of the passive and active heating effect, especially for residential building in the Qinghai-Tibetan plateau areas. In this study, three kinds of heating strategies, including reference condition, passive solar heating condition and active solar heating condition, were tested in one demonstration residential building. The hourly air temperatures of each room under different conditions were obtained and analyzed. The results show the indoor air temperature in the living room and bedrooms (core zones was much higher than that of other rooms under both passive and active solar heating conditions. In addition, the heating effect with different strategies for core zones of the building was evaluated by the ratio of indoor and outdoor degree hour, which indicates that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment. The passive solar heating could undertake 49.8% degree hours for heating under an evaluation criterion of 14 °C and the active solar heating could undertake 75% degree hours for heating under evaluation criterion of 18 °C, which indicated that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment in this area. These findings could provide reference for the design and application of solar heating in similar climate areas.

  13. How can whole house fiscal measures encourage consumers to improve the energy efficiency of their homes?

    International Nuclear Information System (INIS)

    Waterson, Elaine

    2005-01-01

    Over recent years energy efficiency markets in the UK have shown significant growth in the sale of energy efficient white goods and, more recently, efficient boilers. However, despite significant incentives available through energy supplier EEC programmes (a market mechanism), insulation markets have shown limited growth. In particular, cavity wall insulation - the largest single household energy efficiency opportunity in the UK - is difficult to sell. It is a discretionary purchase and not a priority for most consumers. To date UK fiscal measures for energy efficiency have been designed specifically to tackle barriers to the purchase of defined products, including insulation, rather than to tackle the energy efficiency of the house as a whole. For example contractor installed insulation already benefits from 5% VAT, but this is of little or no benefit where insulation is installed for free or is highly subsidised. This paper considers how a more holistic fiscal approach could stimulate consumer action on measures that have, to date, been difficult to sell. Specifically a fiscal approach that focuses on the energy efficiency of the house as a whole. In the context of introduction of the energy report in 2006, under the Energy Performance of Buildings Directive, this paper i) identifies a number of promising new fiscal measures, ii) discusses the prospects for their future success and iii) sets out the contribution that their introduction could make to the UK government's climate change targets and its sustainable energy agenda

  14. Tools and measures for stimulation the efficient energy consumption. Integrated resource planning in Romania

    International Nuclear Information System (INIS)

    Scripcariu, Daniela; Scripcariu, Mircea; Leca, Aureliu

    1996-01-01

    The integrated resource planning is based on analyses of the energy generation and energy consumption as a whole. Thus, increasing the energy efficiency appears to be the cheapest, the most available and the most cost-effective energy resource. In order to stimulate the increase of efficiency of energy consumption, besides economic efficiency criteria for selecting technical solutions, additional tools and measures are necessary. The paper presents the main tools and measures needed to foster an efficient energy consumption. Actions meant to stimulate DSM (Demand-Side Management) implementation in Romania are proposed. The paper contains 5 sections. In the introduction, the main aspects of the DSM are considered, namely, where the programs are implemented, who is the responsible, which are the objectives and finally, how the DSM programs are implemented. The following tools in management of energy use are examined: the energy prices, the regulation in the field of energy efficiency, standards and norms, energy labelling of the products and energy education. Among the measures for managing the energy use, the paper takes into consideration the institutions responsible for DSM, for instance, the Romanian Agency for Energy Conservation (ARCE), decentralization of decision making, the program approaches and financing the actions aiming at improving the energy efficiency. Finally, the paper analyses the criteria in choosing adequate solutions of improving the energy efficiency

  15. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden); Gustavsson, Leif [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden); Mahapatra, Krushna [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden)

    2010-07-15

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed.

  16. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    International Nuclear Information System (INIS)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna

    2010-01-01

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed.

  17. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna [Ecotechnology, Mid Sweden University, SE-83125 Oestersund (Sweden)

    2010-07-15

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed. (author)

  18. Quantum efficiency measurement system for large area CsI photodetectors

    CERN Document Server

    Cusanno, F; Colilli, S; Crateri, R; Fratoni, R; Frullani, S; Garibaldi, F; Giuliani, F; Gricia, M; Lucentini, M; Mostarda, A; Santavenere, F; Veneroni, P; Breuer, H; Iodice, M; Urciuoli, G M; De Cataldo, G; De Leo, R; Lagamba, L; Braem, André

    2003-01-01

    A proximity focusing freon/CsI RICH detector has been built for kaon physics at Thomas Jefferson National Accelerator Facility (TJNAF or Jefferson Lab), Hall A. The Cherenkov photons are detected by a UV photosensitive CsI film which has been obtained by vacuum evaporation. A dedicated evaporation facility for large area photocathodes has been built for this task. A measuring system has been built to allow the evaluation of the absolute quantum efficiency (QE) just after the evaporation. The evaporation facility is described here, as well as the quantum efficiency measurement device. Results of the QE on-line measurements, for the first time on large area photocathodes, are reported.

  19. Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, Anthony C [ORNL; Liu, Xiaobing [ORNL; Koopman, Gary [KCF Technologies; Fugate, David L [ORNL

    2017-01-23

    This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

  20. Measuring of filtration efficiency of nonwoven textiles in volume from scattered light by seeding particles

    Directory of Open Access Journals (Sweden)

    Sidlof P.

    2013-04-01

    Full Text Available This paper deals with the method which calculates a filtration efficiency of nonwoven textiles from scattered light intensity by seeding particles. Thefiltration efficiency is commonly measured by particle counters. Samples of liquid or gas are taken during a test in front of and behind a filtration material. The concentration of particles is measured and the filtration efficiency is calculated. The filtration efficiency does not have to be uniform in itswhole surface. The uniformity of filtration is another indicator of a quality of filtration materials. Measurements described in this article were performed on a water filtration setup which enables optical access to the place where the filtration material is mounted. Pictures of illuminated seeding particles are made by a laser sheet and a camera. Visualisation of the filtration process enables measuring of the efficiency of separation versus time and also versus two-dimensional position in case of use of a traverse mechanism. The filtration textiles were tested by 1 μm seeding particles. Mean value of light intensity and number of bright pixels in evaluative areas during image analysis were obtained. On the basis of these data, the filtration efficiency iscalculated. The best image analysis method was chosen.