  1. INTERIOR DUCT SYSTEM DESIGN, CONSTRUCTION, AND PERFORMANCE

    Energy Technology Data Exchange (ETDEWEB)

    Janet E.R. Mcllvaine; David Beal; Philip Fairey

    2001-10-10

    fresh air inlet design. Improvements were implemented by the Texas builder and retested in July. Results showed a 36% reduction in duct leakage, significant enough to warrant the builder adopting the new sealing procedure.

  2. Residential lighting design

    CERN Document Server

    Steffen, Marcus

    2014-01-01

    Good lighting is essential to a building. An effective design is not just about introducing light into a space, but rather an appreciation of how the space will be used. A good lighting design is so intertwined with the building that it is only noticed in its absence. This book introduces the tools of the lighting designer and explains how to produce a lighting design for a home. Looking at the nature of light and introducing different lamps and light fittings available, it explains the basics of lighting design and how to provide atmosphere through the play of light and shadow. It gives room-

  3. Coupled parametric design of flow control and duct shape

    Science.gov (United States)

    Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)

    2009-01-01

    A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.

  4. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Miller, W.H.; Ornberg, S.C.; Rooney, K.L.

    1981-01-01

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  5. Design requirement on KALIMER control rod assembly duct

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs.

  6. Design requirement on KALIMER control rod assembly duct

    International Nuclear Information System (INIS)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J.

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs

  7. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  8. Design of a Mobile Robot for Air Ducts Exploration

    Directory of Open Access Journals (Sweden)

    Moses A. Koledoye

    2017-10-01

    Full Text Available This work presents the solutions adopted for the design and the implementation of an autonomous wheeled robot developed for the exploration and mapping of air ventilation ducts. The hardware is based on commercial off-the-shelf devices, including sensors, motors, processing devices and interfaces. The mechanical chassis was designed from scratch to meet a trade-off between small size and available volume to host the components. The software stack is based on the Robot Operating System (ROS. Special attention was dedicated to the design of the mobility strategy, which must take into account some constraints and issues that are specific to the considered application, such as the relatively small size of ducts, the need to detect and avoid possible holes on the floor of the duct and other unusual obstacles and the unavailability of external reference frameworks for localization. The main contribution of this paper lies in the design, implementation and experimentation of the overall system.

  9. Advanced Strategy Guideline: Air Distribution Basics and Duct Design

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

  10. Concept design studies on the ITER HNB Duct Liner

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, Sanjay, E-mail: sanjay.mistry@ccfe.ac.uk; Horvat, Andrej; Verhoeven, Roel; Xue, Yongkuan

    2013-10-15

    Highlights: •Engineering design of the ITER Heating Neutral Beam Duct Liner is outlined. •A vector-calculus method is used for calculations which evaluate directional heat flux on different scraper panel layouts. •A scraper panel layout with equal panel lengths and common thermal loading was achieved through these calculations. •The thermo-mechanical performance of a scraper panel satisfies ITER structural design criteria under a normal operation scenario. •Fast blow-out draining is used for complete emptying of a cooling arrangement. •Numerical simulations of the blow-out draining were carried out using RELAP5 and found to demonstrate satisfactory draining. -- Abstract: The Duct Liner for the International Thermonuclear Experimental Reactors (ITER) Heating Neutral Beam (HNB) system is a key component in the beam transport system. Power loading on the top and bottom beam scraping panels of the Duct Liner occurs primarily due to direct interception of the HNB and it is highest at the extreme steering angles of the beam. Furthermore, power loading due to direct interception is dependent on the size and orientation of the scraper panels with respect to the neutral beam axis. This paper outlines the design features of the proposed Duct Liner and describes the analysis performed to optimize the compatibility of the top and bottom scraper panels (also known as Duct Liner Modules) with a normal beam operation scenario. Thermo-mechanical analyses have been performed to validate the design of Duct Liner Modules incorporating deep-drilled cooling technology with a peak power density of 1.2 MW/m{sup 2} and incident power of 0.27 MW, and also to verify its conformity with ITER structural design criteria. Furthermore, numerical simulations of the transient draining procedure were performed by using a one-dimensional thermo-hydraulic code to demonstrate complete emptying of the proposed parallel-layout cooling circuit without any reliance on conventional gravity

  11. ITER L 7 duct remote handling equipment design report

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The operation, design and interfaces of the 'Duct Vehicle' and it's associated remote handling equipment are briefly described in this document. This equipment is being designed by Spar Aerospace Ltd. for the Divertor Test Platform as part of ITER Research and Development Project L-7. Canadian Fusion Fuels Technology Project funds this work as part of the Canadian Contribution to ITER. This document describes the equipment design status at the September 1996 design review. 23 figs

  12. Comparison between predicted duct effectiveness from proposed ASHRAE Standard 152P and measured field data for residential forced air cooling systems; TOPICAL

    International Nuclear Information System (INIS)

    Siegel, Jeffrey A.; McWilliams, Jennifer A.; Walker, Iain S.

    2002-01-01

    The proposed ASHRAE Standard 152P ''Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems'' (ASHRAE 2002) has recently completed its second public review. As part of the standard development process, this study compares the forced air distribution system ratings provided by the public review draft of Standard 152P to measured field results. 58 field tests were performed on cooling systems in 11 homes in the summers of 1998 and 1999. Seven of these houses had standard attics with insulation on the attic floor and a well-vented attic space. The other four houses had unvented attics where the insulation is placed directly under the roof deck and the attic space is not deliberately vented. Each house was tested under a range of summer weather conditions at each particular site, and in some cases the amount of duct leakage was intentionally varied. The comparison between 152P predicted efficiencies and the measured results includes evaluation of the effects of weather, duct location, thermal conditions, duct leakage, and system capacity. The results showed that the difference between measured delivery effectiveness and that calculated using proposed Standard 152P is about 5 percentage points if weather data, duct leakage and air handler flow are well known. However, the accuracy of the standard is strongly dependent on having good measurements of duct leakage and system airflow. Given that the uncertainty in the measured delivery effectiveness is typically also about 5 percentage points, the Standard 152P results are acceptably close to the measured data

  13. Design requirement on KALIMER blanket fuel assembly duct

    International Nuclear Information System (INIS)

    Hwang, Woan; Kang, H. Y.; Nam, C.; Kim, J. O.

    1998-03-01

    This document describes design requirements which are needed for designing the blanket fuel assembly duct of the KALIMER as design guidance. The blanket fuel assembly duct of the KALIMER consists of fuel rods, mounting rail, nosepiece, duct with pad, handling socket with pad. Blanket fuel rod consists of top end plug, bottom end plug with solid ferritic-martensitic steel rod and key way blanket fuel slug, cladding, and wire wrap. In the assembly, the rods are in a triangular pitch array, and the rod bundle is attached to the nosepiece with mounting rails. The bottom end of the assembly duct is formed by a long nosepiece which provides the lower restraint function and the paths for coolant inlet. This report contains functional requirements, performance and operational requirements, interfacing systems requirements, core restraint and interface requirements, design limits and strength requirements, system configuration and essential feature requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. (author). 20 refs., 4 figs

  14. DESIGN ASPECTS OF A RESIDENTIAL WIND GENERATOR

    Directory of Open Access Journals (Sweden)

    C. BRAD

    2017-03-01

    Full Text Available In this paper we present some aspects about the design of a small permanent magnet wind generator with axial magnetic flux often used in residential wind turbine. There are summarised the main steps of the magnetic and electric calculations with applications to a particular case: 0.6 kVA wind generator. The axial flux wind generator design starts with the characteristics of the rare earths permanent magnet existing on the market.

  15. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  16. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A. [ABT Systems, LLC, Annville, PA (United States); Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  17. Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

    Energy Technology Data Exchange (ETDEWEB)

    Beach, Robert [IBACOS Inc., Pittsburgh, PA (United States); Prahl, Duncan [IBACOS Inc., Pittsburgh, PA (United States); Lange, Rich [IBACOS Inc., Pittsburgh, PA (United States)

    2013-12-01

    IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

  18. Limit strength of rectangular air ventilation ducts under-seismic design condition

    International Nuclear Information System (INIS)

    Kato, T.; Nakatogawa, T.; Ichihashi, I.; Takenaka, M.; Nomura, T.

    1989-01-01

    The precise estimation of the limiting strength of heating, ventilating, and air conditioning ducts used in nuclear power plants is a key to the safe and economical design of the seismic supports. The formula for estimating the strength of ducts used up to this time, was derived from test results from small size ducts less than 500mm square. This data was extrapolated to obtain the strength of large ducts and therefore big margins had to be used. Consequently the seismic support spans of rectangular ducts are short and a large bulk volume of seismic support spans rectangular ducts are short and a large bulk volume of seismic support material is used in nuclear power plants. Accordingly, the authors carried out overall pure bending moment tests, shearing load tests, and local buckling load tests using large size rectangular ducts. In this paper the authors present the results of these tests and a method of designing seismic supports safely and economically by using the duct limiting strength estimation formula obtained from these tests

  19. Duct injection technology prototype development: Scale-up methodology and engineering design criteria

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    The objective of the Duct Injection Technology Prototype Development project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2} emissions control method to existing, pre-NSPS, coal-fired power plants. This report is divided into five major topics: (1) design criteria; (2) engineering drawings; (3) equipment sizing and design; (4) plant and equipment arrangement considerations; and (5) equipment bid specification guidelines.

  20. UNDERGROUND AIR DUCT TO CONTROL RISING MOISTURE IN HISTORIC BUILDINGS: IMPROVED DESIGN AND ITS DRYING EFFICIENCY

    Directory of Open Access Journals (Sweden)

    Jiří Pazderka

    2017-10-01

    Full Text Available The underground air ducts along peripheral walls of a building are a remediation method, which principle is to enable an air flow along the moist building structure’s surface to allow a sufficient evaporation of moisture from the structure. This measure reduces the water transport (rising moisture into the higher parts of the wall where the high water content in masonry is undesirable. Presently, underground air ducts are designed as masonry structures, which durability in contact with ground moisture is limited. The article describes a new design of an underground air duct, which is based on specially shaped concrete blocks (without wet processes, because the blocks are completely precast. The air duct from concrete blocks is situated completely below the ground surface (exterior or below the floor (interior. Thanks to this, the system is invisible and does not disturb the authentic look of rehabilitated historic buildings. The efficiency of the air duct technical solution was verified by the results of tests (based on the measured moisture values conducted on a laboratory model. The experimental study showed that the moisture in the masonry equipped with the presented underground air duct had decreased considerably compared to the reference sample, namely by 43 % on average. The experimental study was numerically validated through numerical simulations performed with the program WUFI 2D.

  1. Optimization of the structural design of HVAC ducts and their supports

    International Nuclear Information System (INIS)

    DeMatias, I.P.; Barrio, M.

    1987-01-01

    This paper describes the computerized process of qualification and design based on experience accumulated in structural designs of HVAC systems in nuclear power plants, using CAD/CAE systems. Such computerization has drastically reduced the number of manhours employed to generate the information necessary to issue duct and support fabrication drawings. During the analysis stage, the requirements for qualification of ducts and supports contained in CONAGT ANSI/ASME AG-1 have been considered. The data package applicable to the process consists of a set of computer programs which may be used independently or combined. A significant portion of such programs governs the graphic design. Moreover, analyses are performed on results of the different types of tests carried out to date, and on those necessary to determine the mechanisms of failures in ducts, and in order to be able to calibrate design criteria currently in use

  2. Community Design Parameters and the Performance of Residential Cogeneration Systems

    Directory of Open Access Journals (Sweden)

    Hazem Rashed-Ali

    2012-11-01

    Full Text Available The integration of cogeneration systems in residential and mixed-use communities has the potential of reducing their energy demand and harmful emissions and can thus play asignificant role in increasing their environmental sustainability. This study investigated the impact of selected planning and architectural design parameters on the environmental and economic performances of centralized cogeneration systems integrated into residential communities in U.S.cold climates. Parameters investigated include: 1 density, 2 use mix, 3 street configuration, 4 housing typology, 5 envelope and building systems’ efficiencies, and 6 passive solar energyutilization. The study integrated several simulation tools into a procedure to assess the impact of each design parameter on the cogeneration system performance. This assessment procedure included: developing a base-line model representing typical design characteristics of U.S. residential communities; assessing the cogeneration system’s performance within this model using three performance indicators: percentage of reduction in primary energy use, percentage of reduction in CO2 emissions; and internal rate of return; assessing the impact of each parameter on the system performance through developing 46 design variations of the base-line model representing potential changes in each parameter and calculating the three indicators for each variation; and finally, using a multi-attribute decision analysis methodology to evaluate the relative impact of each parameter on the cogeneration system performance. The study results show that planning parameters had a higher impact on the cogeneration system performance than architectural ones. Also, a significant correlation was found between design characteristics identified as favorable for the cogeneration system performance and those of sustainable residential communities. These include high densities, high use mix, interconnected street networks, and mixing of

  3. Envelope Thermal Design Optimization for Urban Residential Buildings in Malawi

    Directory of Open Access Journals (Sweden)

    Amos Kalua

    2016-04-01

    Full Text Available This study sought to optimize the envelope thermal design of free-running urban residential buildings in Malawi. It specifically set out to improve the urban residential buildings’ thermal comfort and suggest optimal envelope thermal design features for these buildings. The research study was primarily dependent on computer simulations in EnergyPlus to replicate the typical Malawian urban residential building’s thermal behaviour and then study the impacts of various envelope configurations on the thermal comfort conditions registered in the building. The simulation model was experimentally validated to check its appropriateness to the climatic design conditions prevalent in Malawi and out of the three major cities that were considered, the model was found to be appropriate for use in the two cities of Mzuzu and Lilongwe leaving out the city of Blantyre. The optimization methodology that was employed involved the use of orthogonal arrays, statistical analyses and the listing method. It was found that the optimal envelope thermal design, which registered up to 18% lower discomfort hours than that of the typical urban residential building, consists of a 50 mm concrete floor slab, 230 mm burnt brick walls with an external layer of 19 mm EPS, tiled roof with an internal layer of sarking and 50 mm EPS, double Low-E Glazing with a transparency ratio of 45% and 0.2408 m2 of adaptable operational surface area for the air bricks. Out of all the envelope features that were studied, air infiltration registered the most significant contribution towards the ultimate residential building thermal performance. It was demonstrated that controlled air infiltration through the use of operable air bricks whose operational surface area is adaptable can be very effective in enhancing the building’s comfort levels. It was further observed that excessive insulation of the building envelope generally has a detrimental effect on the indoor space thermal comfort

  4. KITCHEN ISLAND FURNITURE DESIGN FOR RESIDENTIAL HOUSES

    Directory of Open Access Journals (Sweden)

    Braileanu Patricia Isabela

    2017-05-01

    Full Text Available In terms of spatial configuration, kitchens design is related to the number of work fronts, shapes and their arrangement in the assembly, storage and distribution areas, as well as the location of the dining place. This paper focuses upon designing a prototype by taking into account the kitchen geometry, as well as different materials and their properties, thus providing an optimum combination of materials likely to ensure a long lifespan of the product at a minimum cost.

  5. Fast flux test facility interim examination and maintenance cell fuel duct cutters: Remote operations design considerations

    International Nuclear Information System (INIS)

    Gibbons, P.W.

    1988-11-01

    Two remotely operated milltype slitting cutters, specifically designed for remote, hot-cell use have been in service in the Fast Flux Test Facility (FFTF) Interim Examination and Maintenance (IEM) Cell for 3 and 4 yr, respectively without the benefit of hands-on maintenance. These cutters are used to sever the outer duct of Driver Fuel Assemblies (DFA) being dismantled for further examination elsewhere. During this period, twelve DFAs requiring duct cutting were dismantled in the IEM Cell. A discussion of the remote design features of those cutters is presented that highlights features that were successful and addresses areas that needed improvement. 3 refs., 7 figs

  6. Parametric Design Strategy Aiming at Environmentally Sustainable Residential Buildings

    DEFF Research Database (Denmark)

    Hansen, Hanne Tine Ring; Knudstrup, Mary-Ann; Heiselberg, Per

    2007-01-01

    This paper presents the preliminary conclusions from a PhD study about methodical approaches to environmentally sustainable architecture. The presented results are from a local sensitivity analysis focused on the energy consumption of a typical residential reference building, when it is subjected...... to a parametric study of the impact of changes in input parameters relating to the design and the use of the building....

  7. Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

  8. Sample design for the residential energy consumption survey

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    The purpose of this report is to provide detailed information about the multistage area-probability sample design used for the Residential Energy Consumption Survey (RECS). It is intended as a technical report, for use by statisticians, to better understand the theory and procedures followed in the creation of the RECS sample frame. For a more cursory overview of the RECS sample design, refer to the appendix entitled ``How the Survey was Conducted,`` which is included in the statistical reports produced for each RECS survey year.

  9. Advanced Strategy Guideline. Air Distribution Basics and Duct Design

    Energy Technology Data Exchange (ETDEWEB)

    Arlan Burdick

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings.

  10. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.

    2001-01-01

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  11. On public space design for Chinese urban residential area based on integrated architectural physics environment evaluation

    Science.gov (United States)

    Dong, J. Y.; Cheng, W.; Ma, C. P.; Tan, Y. T.; Xin, L. S.

    2017-04-01

    The residential public space is an important part in designing the ecological residence, and a proper physics environment of public space is of greater significance to urban residence in China. Actually, the measure to apply computer aided design software into residential design can effectively avoid an inconformity of design intent with actual using condition, and a negative impact on users due to bad architectural physics environment of buildings, etc. The paper largely adopts a design method of analyzing architectural physics environment of residential public space. By analyzing and evaluating various physics environments, a suitability assessment is obtained for residential public space, thereby guiding the space design.

  12. Duct injection technology prototype development: Scale-up methodology and engineering design criteria. Topical report No. 4

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    The objective of the Duct Injection Technology Prototype Development project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2} emissions control method to existing, pre-NSPS, coal-fired power plants. This report is divided into five major topics: (1) design criteria; (2) engineering drawings; (3) equipment sizing and design; (4) plant and equipment arrangement considerations; and (5) equipment bid specification guidelines.

  13. Design and analysis of Air flow duct for improving the thermal performance of disc brake rotor

    Science.gov (United States)

    Raja, T.; Mathiselvan, G.; Sreenivasulureddy, M.; Goldwin Xavier, X.

    2017-05-01

    safety in automotive engineering has been considered as a number one priority in development of new vehicle. A brake system is one of the most critical systems in the vehicle, without which the vehicle will put a passenger in an unsafe position. Temperature distribution on disc rotor brake and the performance brake of disc rotor is influenced by the air flow around the disc rotor. In this paper, the effect of air flow over the disc rotor is analyzed using the CFD software. The air flow over the disc rotor is increased by using a duct to supply more air flow over the disc rotor. The duct is designed to supply more air to the rotor surface and it can be placed in front of the vehicle for better performance. Increasing the air flow around the rotor will maximize the heat convection from the rotor surface. The rotor life and the performance can be improved.

  14. Facade Refurbishment Toolbox. Supporting the Design of Residential Energy Upgrades

    Directory of Open Access Journals (Sweden)

    Thaleia Konstantinou

    2014-07-01

    Full Text Available The starting point of the research is the need to refurbish existing residential building stock, in order to reduce its energy demand, which accounts for over one fourth of the energy consumption in the European Union. Refurbishment is a necessary step to reach the ambitious energy and decarbonisation targets for 2020 and 2050 that require an eventual reduction up to 90% in CO2 emissions. In this context, the rate and depth of refurbishment need to grow. The number of building to be renovated every year should increase, while the energy savings in renovated buildings should be over 60% reduction to current energy demand. To achieve that, not only is it necessary to find politics and incentives, but also to enable the building industry to design and construct effective refurbishment strategies. This research focuses on refurbishment of the building envelope, as it is very influential with regard to energy reduction. The early design phases are particularly important, as decisions taken during this stage can determine the success or failure of the design. Even though the design decisions made earlier can have bigger impact with lower cost and effort, most existing tools focus on post-design evaluation. The integration of all aspects during the early design phases is complex, particularly as far as energy efficient design is concerned. At this stage, architects are in search for a design direction to make an informed decision. If the designer is provided with an indication of how efficient refurbishment options are, it is possible to apply them as part of an integrated strategy rather than trying to add measures at later stages, after the strategy has been developed. Therefore, taking into account the need to refurbish residential buildings and the importance of integrated design of façade refurbishment strategies, the thesis aims at answering the following question. How can the energy upgrade potential of residential façade refurbishment

  15. Design and Implementation of an Innovative Residential PV System

    Science.gov (United States)

    Najm, Elie Michel

    This work focuses on the design and implementation of an innovative residential PV system. In chapter one, after an introduction related to the rapid growth of solar systems' installations, the most commonly used state of the art solar power electronics' configurations are discussed, which leads to introducing the proposed DC/DC parallel configuration. The advantages and disadvantages of each of the power electronics' configurations are deliberated. The scope of work in the power electronics is defined in this chapter to be related to the panel side DC/DC converter. System integration and mechanical proposals are also within the scope of work and are discussed in later chapters. Operation principle of a novel low cost PV converter is proposed in chapter 2. The proposal is based on an innovative, simplified analog implementation of a master/slave methodology resulting in an efficient, soft-switched interleaved variable frequency flybacks, operating in the boundary conduction mode (BCM). The scheme concept and circuit configuration, operation principle and theoretical waveforms, design equations, and design considerations are presented. Furthermore, design examples are also given, illustrating the significance of the newly derived frequency equation for flybacks operating in BCM. In chapters 3, 4, and 5, the design implementation and optimization of the novel DC/DC converter illustrated in chapter 2 are discussed. In chapter 3, a detailed variable frequency BCM flyback design model leading to optimizing the component selections and transformer design, detailed in chapter 4, is presented. Furthermore, in chapter 4, the method enabling the use of lower voltage rating switching devices is also discussed. In chapter 5, circuitry related to Start-UP, drive for the main switching devices, zero-voltage-switching (ZVS) as well as turn OFF soft switching and interleaving control are fully detailed. The experimental results of the proposed DC/DC converter are presented in

  16. Optimum design of the injection duct system of a stenter machine

    Energy Technology Data Exchange (ETDEWEB)

    Juraeva, Makhsuda; Song, Dong Joo [Yeungnam University, Geyongsan (Korea, Republic of); Ryu, Kyung Jin [Ajou Motor College, Boryeong (Korea, Republic of)

    2017-05-15

    Stenter machines are used for drying fabrics in the textile industry and have a heater, injection duct system, and fans inside a chamber. The injection duct system has ducts and air-injecting holes. Plane-type injection duct systems were investigated to obtain uniform airflow at the air-injecting holes. The flow field of the injection duct systems was computed using ANSYS CFX with different heights of the duct end and different shapes for the air-injecting holes. There was a high mass flow rate at the air-injecting holes and high airflow circulation inside both plane-type and mountain-type ducts at the ends. The height of the duct end was varied between 40 mm and 160 mm. The injection duct systems were analyzed with four different shapes of air-injecting holes. The circular and elliptical holes had lower standard deviations of the mass flow rate than other shapes. Relatively uniform mass flow rates were obtained in the plane-type and mountain-type duct systems when the height of the duct end was 40 mm and the shape of the air-injecting holes was circular or elliptical. The developed injection duct systems were improved by obtaining a uniform mass flow rate at the air-injecting holes. A stenter prototype was fabricated with the developed injection duct system to confirm the numerical results. The developed injection duct system had better performance than the original system.

  17. Residential hospice environments: evidence-based architectural and landscape design considerations.

    Science.gov (United States)

    Verderber, Stephen

    2014-01-01

    The residential hospice care movement is increasingly accepted and supported globally, and yet, unfortunately, the amount of literature on best practices in the planning and design of residential hospice facilities and adjacent outdoor spaces remains relatively small. This paper reports on a compendium of architectural and landscape design considerations that reflect the fundamental dimensions of the residential hospice experience: site and context, arrival spaces, communal and private spaces of the residential milieu, transitional spaces, and nature connectivity. Additionally, key staffing and administrative ramifications of this built-environment compendium are addressed, as are prognostications and challenges for the future.

  18. Advances in Residential Design Related to the Influence of Geomagnetism

    Science.gov (United States)

    Arnedo, Israel; Sánchez-Ostiz, Ana

    2018-01-01

    Since the origin of the Modern Movement, there has been a basic commitment to improving housing conditions and the well-being of occupants, especially given the prediction that 2/3 of humanity will reside in cities by 2050. Moreover, a compact model of the city with tall buildings and urban densification at this scale will be generated. Continuous constructive and technological advances have developed solid foundations on safety, energy efficiency, habitability, and sustainability in housing design. However, studies on improving the quality of life in these areas continue to be a challenge for architects and engineers. This paper seeks to contribute health-related information to the study of residential design, specifically the influence of the geomagnetic field on its occupants. After compiling information on the effects of geomagnetic fields from different medical studies over 23 years, a case study of a 16-story high-rise building is presented, with the goal of proposing architectural design recommendations for long-term occupation in the same place. The purpose of the present work is three-fold: first, to characterize the geomagnetic field variability of buildings; second, to identify the causes and possible related mechanisms; and third, to define architectural criteria on the arrangement of uses and constructive elements for housing. PMID:29473902

  19. Robust D-Stability Controller Design for a Ducted Fan Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Xiao-lu Ren

    2014-01-01

    Full Text Available This paper deals with the aerodynamic modeling of a small ducted fan UAV and the problem of attitude stabilization when the parameter of the vehicle is varied. The main aerodynamic model of the hovering flight UAV is first presented. Then, an attitude control is designed from a linearization of the dynamic model around the hovering flight, which is based on the H∞ output feedback control theory with D-stability. Simulation results show that such method has good robustness to the attitude system. They can meet the requirements of attitude control and verify further the feasibility of such a control strategy.

  20. Design and optimization of zero-energy-consumption based solar energy residential building systems

    Science.gov (United States)

    Zheng, D. L.; Yu, L. J.; Tan, H. W.

    2017-11-01

    Energy consumption of residential buildings has grown fast in recent years, thus raising a challenge on zero energy residential building (ZERB) systems, which aim at substantially reducing energy consumption of residential buildings. Thus, how to facilitate ZERB has become a hot but difficult topic. In the paper, we put forward the overall design principle of ZERB based on analysis of the systems’ energy demand. In particular, the architecture for both schematic design and passive technology is optimized and both energy simulation analysis and energy balancing analysis are implemented, followed by committing the selection of high-efficiency appliance and renewable energy sources for ZERB residential building. In addition, Chinese classical residential building has been investigated in the proposed case, in which several critical aspects such as building optimization, passive design, PV panel and HVAC system integrated with solar water heater, Phase change materials, natural ventilation, etc., have been taken into consideration.

  1. Criteria of Architectural Composition Design in Residential Courtyards

    Science.gov (United States)

    Ziemeļniece, Aija; Īle, Una

    2017-10-01

    The totalitarian times of the 50s-80s of the 20th century have brought the building of high-rise residential blocks in Latvian cities, characterized by an uninteresting solution of standard buildings and the alien scale which does not meet the regional features. During the above period, areas of the residential courtyards have not been addressed. The conclusion of the research is that today the courtyards of the high-rise residential houses have become a stagnant, functionally irrelevant area that forms a depressing nature of the outdoor living space. The uncharted area of courtyards is not being used fully which highlights a wide range of issues that applies to car parks, recreation areas, and the green areas. With the development of the urban infrastructure, the creation of high-rise parking facilities and separate car parks are insufficiently addressed. Consequently, the implementation of improvements in courtyards of high-rise residential houses is not possible if the above issue on the removal of the car load from courtyards is not solved. Many building districts are characterized by the same compositional, architectural-spatial structure which even more influences and causes discomfort in these areas to stay. In recent years, the solution to the above issue is sought by the municipal authorities of Latvia to create a new courtyard zoning. It applies to the project development and construction works. In the research, courtyards of the city of Jelgava are analysed and evaluated which from the qualitative point of view demonstrates and is a vivid example where the issues of the research are readable. The city of Jelgava, located 45 km away from Riga, is an expressed satellite city and serves for the agglomeration of Riga as a huge high-rise residential district. Consequently, the research includes separate courtyards of high-rise residential buildings of the city of Jelgava and their study is carried out from the point of view of the architectural composition

  2. Optimization of Ducted Propeller Design for the ROV (Remotely Operated Vehicle using CFD

    Directory of Open Access Journals (Sweden)

    Aldias Bahatmaka

    2016-11-01

    Full Text Available The development of underwater robot technology is growing rapidly. For reaching the best performance, it is important that the innovation on ROV should be focused on the thruster and propeller.In this research, the ducted propeller thruster is used while three types of SHUSKHIN nozzle are selected. The design is compared in accordance with the thruster that has been made as the propulsion device of underwater robots. Each type of the thruster model indicates different force and torque. For the analysis, each model is built in Computer Aided Design (Rhinoceros program packages and Computational Fluid Dynamics (CFD to find the most optimal model which can produce the highest thrust. Among the entire model, the Kaplan series (Ka5-75 with the type C of nozzle has the highest thrust which is 2.53 N or 25.24% of extra thrust.For the optimization of thrust, genetic Algorithms (GA is used. The GA can search for parameters in large multi-dimensional design space. Thus, the principle can be applied for determining the initial propeller that produces optimum thrust of ROV. The GA has successfully shown able to obtain an optimal set parameters for propeller characteristics with the best performance.

  3. Designing on-Board Data Handling for EDF (Electric Ducted Fan) Rocket

    Science.gov (United States)

    Mulyana, A.; Faiz, L. A. A.

    2018-02-01

    The EDF (Electric Ducted Fan) rocket to launch requires a system of monitoring, tracking and controlling to allow the rocket to glide properly. One of the important components in the rocket is OBDH (On-Board Data Handling) which serves as a medium to perform commands and data processing. However, TTC (Telemetry, Tracking, and Command) are required to communicate between GCS (Ground Control Station) and OBDH on EDF rockets. So the design control system of EDF rockets and GCS for telemetry and telecommand needs to be made. In the design of integrated OBDH controller uses a lot of electronics modules, to know the behavior of rocket used IMU sensor (Inertial Measurement Unit) in which consist of 3-axis gyroscope sensor and Accelerometer 3-axis. To do tracking using GPS, compass sensor as a determinant of the direction of the rocket as well as a reference point on the z-axis of gyroscope sensor processing and used barometer sensors to measure the height of the rocket at the time of glide. The data can be known in real-time by sending data through radio modules at 2.4 GHz frequency using XBee-Pro S2B to GCS. By using windows filter, noises can be reduced, and it used to guarantee monitoring and controlling system can work properly.

  4. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, Robert [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, Bruce [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, Anthony [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, Ari [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-10

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  5. A Plug-and-Play Duct System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States); Dickson, B. [IBACOS, Inc., Pittsburgh, PA (United States); Grisolia, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Rapport, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

  6. High-Performance Ducts in Hot-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chitwood, Rick [National Renewable Energy Laboratory (NREL), Golden, CO (United States); German, Alea [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Weitzel, Elizabeth [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-30

    Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

  7. Center for Real Life Kitchen Design open house to showcase latest in residential kitchens

    OpenAIRE

    Elliott, Jean

    2007-01-01

    Virginia Tech will unveil its newly refurbished Center for Real Life Kitchen Design at an open house set for Monday, April 2. The 1,500-square foot center, located in 247 Wallace Hall, features six fully functional residential kitchen designs that reflect a variety of price levels, lifestyles, and use of space for today's homeowner.

  8. Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

    Science.gov (United States)

    1978-01-01

    A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  9. Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  10. IEA Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    with heat recovery systems, one of the next focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or to make it in a new way demand controlled. However, this must be done such that it has no have adverse effects...... on Indoor Air Quality (IAQ). Annex 68, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy...... the hygrothermal parameters, the chemical conditions, ventilation and the wellbeing of occupants. A flagship outcome of the project is anticipated to be a guidebook on design and operation of ventilation in residential buildings to achieve high IAQ with smallest possible energy consumption....

  11. An International Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or making it in a new way demand controlled. However, this must be done such that it does not have adverse effects on indoor air quality (IAQ). Annex 68......, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy performance whilst providing...... studies. A flagship outcome of the project will be a guidebook on design and operation of ventilation in residential buildings to achieve high IAQ with least possible energy consumption. The paper illustrates the working program of each of these activities....

  12. Nucleonic analysis of a preliminary design for the ETF neutral-beam-injector duct shielding

    International Nuclear Information System (INIS)

    Urban, W.T.; Seed, T.J.; Dudziak, D.J.

    1980-01-01

    A nucleonic analysis of the Engineering Test Facility Neutral-Beam-Injector duct shielding has been made using a hybrid Monte Carlo/discrete-ordinates method. This method used Monte Carlo to determine internal and external boundary surface sources for a subsequent discrete-ordinates calculation of the neutron and gamma-ray transport through the shield. The analysis also included determination of the energy and angular distribution of neutrons and gamma rays entering the duct from the torus plasma chamber. Confidence in the hybrid method and the results obtained were provided through a comparison with three-dimensional Monte Carlo results

  13. Virtual Environment as a Design Tool for Sustainable Residential Spaces in Light of Theory of Planned Behavior

    Directory of Open Access Journals (Sweden)

    Hebatalla Sherin Nazmy

    2016-01-01

    Full Text Available This study aims to reveal the impact of Virtual Environment as a design tool on the interior architect's design behavior towards adopting sustainable residential interior design practices. This approach is guided by the Theory of Planned Behaviour as a theoretical framework; the purpose as such would serve to bridge the gap between theoretical knowledge and its practical implementation to promote sustainable design practices. Findings revealed that Virtual Environment is anticipated to assist the interior architect in integrating the complex sustainable residential design objectives, and thus positively affect the interior architect's behavioral performance towards embracing sustainable residential design solutions.

  14. Stability analysis and design of time-domain acoustic impedance boundary conditions for lined duct with mean flow.

    Science.gov (United States)

    Liu, Xin; Huang, Xun; Zhang, Xin

    2014-11-01

    This work develops the so-called compensated impedance boundary conditions that enable stable time domain simulations of sound propagation in a lined duct with uniform mean flow, which has important practical interest for noise emission by aero-engines. The proposed method is developed analytically from an unusual perspective of control that shows impedance boundary conditions act as closed-loop feedbacks to an overall duct acoustic system. It turns out that those numerical instabilities of time domain simulations are caused by deficient phase margins of the corresponding control-oriented model. A particular instability of very low frequencies in the presence of steady uniform background mean flow, in addition to the well known high frequency numerical instabilities at the grid size, can be identified using this analysis approach. Stable time domain impedance boundary conditions can be formulated by including appropriate phaselead compensators to achieve desired phase margins. The compensated impedance boundary conditions can be simply designed with no empirical parameter, straightforwardly integrated with ordinary linear acoustic models, and efficiently calculated with no need of resolving sheared boundary layers. The proposed boundary conditions are validated by comparing against asymptotic solutions of spinning modal sound propagation in a duct with a hard-soft interface and reasonable agreement is achieved.

  15. Solar Heating and Cooling of Residential Buildings: Design of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This is the second of two training courses designed to develop the capability of practitioners in the home building industry to design solar heating and cooling systems. The course is organized in 23 modules to separate selected topics and to facilitate learning. Although a compact schedule of one week is shown, a variety of formats can be…

  16. Exploring Socio-Technical Features of Green Interior Design of Residential Buildings: Indicators, Interdependence and Embeddedness

    Directory of Open Access Journals (Sweden)

    Yan Ning

    2016-12-01

    Full Text Available This research aims to develop indicators for assessing green interior design of new residential buildings in China, grounded in the socio-technical systems approach. The research was carried out through a critical literature review and two focus group studies. The results show that the boundaries of green interior design were identified with respect to three dimensions, namely performance, methodology and stakeholders. The socio-technical systems approach argues for the recognition of the interdependence between the systems elements and the feature of embeddedness. The interdependence of the systems elements exists within each of these three dimensions and across them. It is also found that the socio-technical systems of green interior design are embedded in the social, regulatory and geographic context. Taking interior design of residential buildings as the empirical setting, this study contributes to the literature of green building assessment by presenting a socio-technical systems approach.

  17. Teaching Residential Design Based on a Multicultural Education Ideology

    Science.gov (United States)

    Read, Marilyn A.; Owens, Nancy J.

    2011-01-01

    This experiential teaching method demonstrates students' enhanced understanding of the influences that cross-cultural perspectives have on the interior design of the home and is achieved through research and application of elements of assimilation and acculturation in the United States. Knowledge of human factors, family dynamics, geographic…

  18. How architectural design affords experiences of freedom in residential care for older people.

    Science.gov (United States)

    Van Steenwinkel, Iris; Dierckx de Casterlé, Bernadette; Heylighen, Ann

    2017-04-01

    Human values and social issues shape visions on dwelling and care for older people, a growing number of whom live in residential care facilities. These facilities' architectural design is considered to play an important role in realizing care visions. This role, however, has received little attention in research. This article presents a case study of a residential care facility for which the architects made considerable effort to match the design with the care vision. The study offers insights into residents' and caregivers' experiences of, respectively, living and working in this facility, and the role of architectural features therein. A single qualitative case study design was used to provide in-depth, contextual insights. The methods include semi-structured interviews with residents and caregivers, and participant observation. Data concerning design intentions, assumptions and strategies were obtained from design documents, through a semi-structured interview with the architects, and observations on site. Our analysis underlines the importance of freedom (and especially freedom of movement), and the balance between experiencing freedom and being bound to a social and physical framework. It shows the architecture features that can have a role therein: small-scaleness in terms of number of residents per dwelling unit, size and compactness; spatial generosity in terms of surface area, room to maneuver and variety of places; and physical accessibility. Our study challenges the idea of family-like group living. Since we found limited sense of group belonging amongst residents, our findings suggest to rethink residential care facilities in terms of private or collective living in order to address residents' social freedom of movement. Caregivers associated 'hominess' with freedom of movement, action and choice, with favorable social dynamics and with the building's residential character. Being perceived as homey, the facility's architectural design matches caregivers

  19. Modeling and forecasting residential loads as probabilistic currents for LV network design

    Energy Technology Data Exchange (ETDEWEB)

    Herman, R.; Gaunt, C.T. [Cape Town Univ., Rondebosch (South Africa)

    2007-07-01

    This paper presented different approaches to the design of low voltage (LV) electrical distribution systems found in North America and Europe. Systems based on the European approach have long LV feeders that require careful consideration at the design stage. The common basic principle of the 2 different systems is the uncertainty associated with customer loads due to their stochastic behaviour. The most important criterion in conductor sizing is the estimation of the design loads. This comparative study of various deterministic design procedures was conducted in response to concerns regarding the validity and accuracy of design calculations. The study involved extensive residential load modeling and probabilistic design methods. It described how the Beta probability density function (PDF) is used in South Africa to describe the statistical properties of residential loads. The Beta parameters may be readily applied in voltage design calculations. The study demonstrated how these load parameters may be derived in other developing countries from a typical customer group after-diversity-maximum demand (ADMD) survey. The Herman Beta algorithm can be used to calculate feeder voltage drop, given the relationship between ADMD and the Beta load parameters .8 refs., 5 figs.

  20. California residential energy standards: problems and recommendations relating to implementation, enforcement, and design. [Thermal insulation

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    Documents relevant to the development and implementation of the California energy insulation standards for new residential buildings were evaluated and a survey was conducted to determine problems encountered in the implementation, enforcement, and design aspects of the standards. The impact of the standards on enforcement agencies, designers, builders and developers, manufacturers and suppliers, consumers, and the building process in general is summarized. The impact on construction costs and energy savings varies considerably because of the wide variation in prior insulation practices and climatic conditions in California. The report concludes with a series of recommendations covering all levels of government and the building process. (MCW)

  1. Dramix® Steel fibres in residential foundation slabs in Czech Republic: design approach

    Science.gov (United States)

    Pouillon, S.

    2017-09-01

    Steel fibres are used more and more in structural concrete elements, like residential foundation slabs. The development of high performant steel fibres (e.g. Dramix® 4D and 5D), the evolution in standardization and the demand coming from construction companies and investors are pushing this trend. Engineers are using the yield line method to design steel fibre concrete structures in an easy and economical way, especially if the structure has a regular load layout mainly containing wall loads and point loads. The load configuration, soil characteristics and material characteristics determine the final solution.

  2. Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

    Energy Technology Data Exchange (ETDEWEB)

    Bird, Lori [National Renewable Energy Lab. (NREL), Golden, CO (United States); Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); McLaren, Joyce [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, John [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset, on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.

  3. Temporal De-biasing of Behaviour in Residential Energy Consumption: Supporting Conservation Compliance Through Feedback Design

    Science.gov (United States)

    Trinh, Kevin

    Despite years of research in residential energy conservation, means of inducing conservation behaviour through feedback are not well understood. In this thesis I take a novel approach to feedback design by addressing temporal inconsistencies that may hinder individuals from forming an intention to conserve. To help understand conservation compliance strategies, I proposed a visual framework to categorize interventions. I present two design heuristics that were inspired by temporal construal theory (Liberman & Trope, 2003). They were the impetus for the design of three feedback display prototypes, which were examined. Due to methodological limitations, significant improvements to compliance were not found. However, evidence suggests that comparative feedback may have supported reasoning about conservation rather than supporting conservation compliance directly. Future work includes refinement of feedback displays to avoid direct comparisons, exploring the use of nature imagery, and the study of a possible interaction between environmental values and comparative feedback on compliance.

  4. A three-dimensional model of residential energy consumer archetypes for local energy policy design in the UK

    International Nuclear Information System (INIS)

    Zhang Tao; Siebers, Peer-Olaf; Aickelin, Uwe

    2012-01-01

    This paper reviews major studies in three traditional lines of research in residential energy consumption in the UK, i.e., economic/infrastructure, behaviour, and load profiling. Based on the review the paper proposes a three-dimensional model for archetyping residential energy consumers in the UK by considering property energy efficiency levels, the greenness of household behaviour of using energy, and the duration of property daytime occupancy. With the proposed model, eight archetypes of residential energy consumers in the UK have been identified. They are: pioneer greens, follower greens, concerned greens, home stayers, unconscientious wasters, regular wasters, daytime wasters, and disengaged wasters. Using a case study, these archetypes of residential energy consumers demonstrate the robustness of the 3-D model in aiding local energy policy/intervention design in the UK. - Highlights: ► This paper reviews the three traditional lines of research in residential energy consumption in the UK. ► Based on the literature review, the paper proposes a 3-D conceptual model for archetyping UK residential energy consumers. ► The 3-D archetype model can aid local energy policy/intervention design in the UK.

  5. Residential energy efficiency retrofits: How program design affects participation and outcomes

    International Nuclear Information System (INIS)

    Hoicka, Christina E.; Parker, Paul; Andrey, Jean

    2014-01-01

    Better methods of characterizing and addressing heterogeneity in preferences and decision making are needed to stimulate reductions in household greenhouse gas emissions. Four residential energy efficiency programs were delivered consecutively in the Region of Waterloo, Canada, between 1999 and 2011, and each offered a unique combination of information, financial reward structure, and price. A natural quasi-experimental intervention design was employed to assess differences in outcomes across these program structures. Participation at the initial (evaluation by an energy advisor) and follow-up (verification of retrofit) stages, and the material characteristics (e.g., energy performance) were measured and compared between the groups of houses included in each program at each stage. The programs appealed to people with different types of material concerns; each phase of the program was associated with houses with a different mix of material characteristics and depths of recommended and achieved changes. While a performance-based reward attracted fewer houses at each stage than a larger list-based reward, older houses with poorer energy performance were included at each stage. The findings support experimentation with program designs to target sub-populations of housing stock; future program designs should experiment more carefully and with larger performance-based rewards and test parallels with potential carbon market structures. - Highlights: • Multi-program data over 12 years detailing residential energy retrofits. • Natural experimental intervention research design for program evaluation. • Number and attributes of participating households differed by program design. • Financial rewards attracted more participants to the verification stage. • Performance-based incentives have the largest potential for energy savings

  6. A DFuzzy-DAHP Decision-Making Model for Evaluating Energy-Saving Design Strategies for Residential Buildings

    Directory of Open Access Journals (Sweden)

    Yu-Lung Chen

    2012-11-01

    Full Text Available The construction industry is a high-pollution and high-energy-consumption industry. Energy-saving designs for residential buildings not only reduce the energy consumed during construction, but also reduce long-term energy consumption in completed residential buildings. Because building design affects investment costs, designs are often influenced by investors’ decisions. A set of appropriate decision-support tools for residential buildings are required to examine how building design influences corporations externally and internally. From the perspective of energy savings and environmental protection, we combined three methods to develop a unique model for evaluating the energy-saving design of residential buildings. Among these methods, the Delphi group decision-making method provides a co-design feature, the analytical hierarchy process (AHP includes multi-criteria decision-making techniques, and fuzzy logic theory can simplify complex internal and external factors into easy-to-understand numbers or ratios that facilitate decisions. The results of this study show that incorporating solar building materials, double-skin facades, and green roof designs can effectively provide high energy-saving building designs.

  7. Solar heating and cooling of residential buildings: design of systems, 1980 edition

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This manual was prepared primarily for use in conducting a practical training course on the design of solar heating and cooling systems for residential and small office buildings, but may also be useful as a general reference text. The content level is appropriate for persons with different and varied backgrounds, although it is assumed that readers possess a basic understanding of heating, ventilating, and air-conditioning systems of conventional (non-solar) types. This edition is a revision of the manual with the same title, first printed and distributed by the US Government Printing Office in October 1977. The manual has been reorganized, new material has been added, and outdated information has been deleted. Only active solar systems are described. Liquid and air-heating solar systems for combined space and service water heating or service water heating are included. Furthermore, only systems with proven experience are discussed to any extent.

  8. Design of the segment structure and coolant ducts for a fusion reactor blanket and shield

    International Nuclear Information System (INIS)

    Briaris, D.A.; Stanbridge, J.R.

    1978-05-01

    An outline design and analysis of a support structure for the replaceable first wall of a helium cooled fusion reactor blanket has been undertaken. The proposed structure supports all the segment gravitational loads with maximum deflections limited to < 10 mm, and is itself supported off the outer shield by a simple vee-in-groove arrangement. It is a feature of the design that the coaxial coolant pipes and the segment structure operate at the same temperature, making it possible for them to be integrated, thereby avoiding the necessity for pipe bellows. The requirements of cooling the inner arm of the structure and increasing the major radius of the torus by approximately = 0.5 m, have been identified as problems associated with the 'horseshoe' shaped structure applicable to the reactor with divertor. For a ring structure, i.e. reactor without divertor, these problems do not arise. (author)

  9. Environmental Design Consideration for Courtyards in Residential Buildings in Hot-humid Climates: A Review

    Directory of Open Access Journals (Sweden)

    Mohd Azuan Zakaria

    2014-11-01

    Full Text Available This paper discusses environmental design considerations for courtyards in residential buildings in hot-humid climates through a literature review by contrasting with those in hot-dry climates. The main focus of discussion is on shading and ventilation effects of courtyards. The results of the analysis revealed that the form and orientation of a courtyard were less significant in its environmental design considerations for the hot-humid climates. Although these factors were reported to be the most important design considerations in the case of hot-dry climates. Mean-while, natural ventilation has been commonly utilized in wooden-structured traditional build-ings in hot-humid climates. However, most of the urban houses in Southeast Asian regions are becoming heavy-weight brick-walled buildings nowadays. It could be seen that the required environmental effects of a courtyard and its design considerations in the case of high thermal mass buildings in hot-humid climates are still uncertain and need to be investigated further.

  10. Strength Evaluation of a Preliminary Hot Gas Duct Design for the NHDD Program

    International Nuclear Information System (INIS)

    Song, Keenam; Kim, Y. W; Lee, S. B.

    2007-01-01

    Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for a nuclear hydrogen generation. The VHTR can produce hydrogen from heat and water by using a thermo-chemical process or from heat, water, and natural gas by steam reformer technology. The NHDD program being researched at KAERI is planning to produce hydrogen by using nuclear energy and a thermo-chemical process. Helium gas is the choice for the coolant of the NHDD program since it is an inert gas, with no affinity to a chemical or nuclear activity, therefore a radioactivity transport in the primary circuit of the NHDD program is minimal under a normal operation. Moreover, its gaseous nature avoids problems related to a phase change and water-metal reactions and therefore improves its safety. In this study, a strength evaluation for the HGD of the NHDD program has been undertaken based on the HTR- 10 design concepts

  11. Applicability research on passive design of residential buildings in hot summer and cold winter zone in China

    Science.gov (United States)

    Zhang, Hui; Wang, Huihui; Zhou, Xuan

    2017-04-01

    Passive design has long been a concern as an effective way of building energy efficiency. However, different urban climate characteristics determine the time-effectiveness of passive design. According to the climate characteristics of hot summer and cold winter zone in China, this research chose five cities, Shanghai, Wuhan, Chongqing, Nanjing and Changsha, to analyze their residential building energy consumption and thermal environment conditions. Based on Weather Tool calculation and analysis, the purpose of this research is to put forward the concept of Suitable Degree (SD), namely the applicability of the passive design. In addition, five cities’ SD of passive design technology had been analyzed from aspect of ventilation, temperature, solar radiation and envelope, then passive design strategies and methods of five cities’ residential building were discussed.

  12. ITER L 6 equatorial maintenance duct remote handling study

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The status and conclusions of a preliminary study of equatorial maintenance duct remote handling is reported. Due to issues with the original duct design a significant portion of the study had to be refocused on equatorial duct layout studies. The study gives an overview of some of the options for design of these ducts and the impact of the design on the equipment to work in the duct. To develop a remote handling concept for creating access through the ducts the following design tasks should be performed: define the operations sequences for equatorial maintenance duct opening and closing; review the remote handling requirements for equatorial maintenance duct opening and closing; design concept for door and pipe handling equipment and to propose preliminary procedures for material handling outsides the duct. 35 figs

  13. Construction and design defects in the residential buildings and observed earthquake damage types in Turkey

    Science.gov (United States)

    Cogurcu, M. T.

    2015-04-01

    Turkey is situated in a very active earthquake region. In the last century, several earthquakes resulted in thousands of deaths and enormous economic losses. In 1999, the Kocaeli earthquake had an approximate death toll of more than 20 000, and in 2011 the Van earthquake killed 604 people. In general, Turkish residential buildings have reinforced concrete structural systems. These reinforced concrete structures have several deficiencies, such as low concrete quality, non-seismic steel detailing and inappropriate structural systems including several architectural irregularities. In this study, the general characteristics of Turkish building stock and the deficiencies observed in structural systems are explained, and illustrative figures are given with reference to the Turkish Earthquake Code 2007. The poor concrete quality, lack of lateral or transverse reinforcement in beam-column joints and column confinement zones, high stirrup spacings, under-reinforced columns and over-reinforced beams are the primary causes of failures. Other deficiencies include weak-column-stronger-beam formations, insufficient seismic joint separations, soft-story or weak-story irregularities and short columns. Similar construction and design mistakes are also observed in other countries situated on active earthquake belts. Existing buildings still have these undesirable characteristics, and so to prepare for future earthquakes they must be rehabilitated.

  14. Dynamic integration of residential building design and green energies : the Bireth approach : building integrated renewable energy total harvest approach

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, K.P. [Hong Kong Univ., Hong Kong (China). Dept. of Architecture; Luk, C.L.P. [Chu Hai College of Higher Education, Hong Kong (China). Dept. of Architecture; Wong, S.T. [Hong Kong Univ., Hong Kong (China). Div. of Arts and Humanities, SPACE; Chung, S.L.; Fung, K.S.; Leung, M.F. [Hong Kong Inst. of Vocational Education, Hong Kong (China)

    2006-07-01

    Renewable energy sources that are commonly used in buildings include solar energy, wind energy and rainwater collection. High quality environmentally responsive residential buildings are designed to provide good insulation in winter and solar shading in summer. However, this study demonstrated that the green energy design in residential buildings is not usually well integrated. For example, windows with clear double or triple glazed glass, allow good penetration of sunlight during the day in winter, but are not further dynamically insulated for when the sun goes down to avoid heat loss from the building. Additionally, good solar static shading devices often block much needed daylight on cloudy winter days. These examples emphasize the lack of an integrated approach to gain the best advantage of green energies and to minimize energy costs in residential buildings. This study addressed issues facing the integrated approach with particular reference to the design of a small residential building in rural Beijing. The design included a new approach for interpreting a traditional Beijing court yard house in the modern Beijing rural context, while integrating multi-responding innovative green energy applications derived from first principles. This paper also presented a proposal for a village house in Hong Kong to harvest as much renewable energies as possible, primarily wind energy and solar energy, that come into contact with the building. The purpose was to work towards a renewable energy approach for buildings, namely the Bireth approach, which will benefit practically all houses by making them zero energy houses. The paper described the feasibility of integrating renewable energies in buildings to fulfill performance requirements such improving ventilation, providing warm interiors, drying clothes, or storing solar and wind energies into power batteries. The challenges facing the development of a proposed micro solar hot air turbine were also presented. 15 refs., 6

  15. Emergency residential care settings: A model for service assessment and design.

    Science.gov (United States)

    Graça, João; Calheiros, Maria Manuela; Patrício, Joana Nunes; Magalhães, Eunice Vieira

    2018-02-01

    There have been calls for uncovering the "black box" of residential care services, with a particular need for research focusing on emergency care settings for children and youth in danger. In fact, the strikingly scant empirical attention that these settings have received so far contrasts with the role that they often play as gateway into the child welfare system. To answer these calls, this work presents and tests a framework for assessing a service model in residential emergency care. It comprises seven studies which address a set of different focal areas (e.g., service logic model; care experiences), informants (e.g., case records; staff; children/youth), and service components (e.g., case assessment/evaluation; intervention; placement/referral). Drawing on this process-consultation approach, the work proposes a set of key challenges for emergency residential care in terms of service improvement and development, and calls for further research targeting more care units and different types of residential care services. These findings offer a contribution to inform evidence-based practice and policy in service models of residential care. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Fan Duct Heat Exchanger for Turbine Cooling Air, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposal is for the design of a fan duct heat exchanger in order to improve aircraft fuel burn. The fan duct heat exchanger decreases the temperature of the 15%...

  17. Technology Solutions Case Study: High-Performance Ducts in Hot-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, A. German, E. Weitzel, R. Chitwood

    2015-08-01

    Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

  18. On methods of sustainable architectural design of bio-positive buildings in the low-rise residential development structure

    Directory of Open Access Journals (Sweden)

    Zhogoleva Anna

    2017-01-01

    Full Text Available The purpose of the author’s research is to determine the actual content of sustainable architectural design for suburban residential development. In accordance with the methodology of area sustainable development the traditional architectural design according to the rules and regulations is completed with additional approaches and methods. As a result, methods of bio-positive design of buildings have been studied and defined, including: the principle of planning transformations, the use of environmentally friendly, local building materials and design concepts, energy-efficient architectural design, the use of alternative energy in building operation, the design of the energy intake and accumulationsystems, the architectural and landscape design that ensures stable functioning of autonomous, sustainable biosystems on the site, non-waste functioning of architectural objects, introduction of waste disposal systems in the project.

  19. A Comparison of Simulation Capabilities for Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Smith, Matt K [ORNL; Gu, Lixing [Florida Solar Energy Center (FSEC); New, Joshua Ryan [ORNL

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  20. Aerodynamic Design and Analysis of Propellers for Mini-Remotely Piloted Air Vehicles. Volume 2. Ducted Propellers

    Science.gov (United States)

    1978-05-01

    110 28t UT__n M t : X . (.4 u~..4 I 1: H 1 1I 1C . Al 0 -fUS~PD IM’ T! I I t-n!2n I 0 0 00N 0 n 0 r%~ 00 SON lca . LMNn L 0 M Nm 0nL 300 DUCTED...PROPELLERS The existing RPV’s incorporate shrouds to protect the propeller from damage and operating personnel from injury . The shrouds used are not

  1. Residential tornado safe room from commodity wood products – design and development

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2018-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms have helped decrease the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a nonproprietary residential tornado safe...

  2. Fall prevention and safety communication training for foremen: report of a pilot project designed to improve residential construction safety.

    Science.gov (United States)

    Kaskutas, Vicki; Dale, Ann Marie; Lipscomb, Hester; Evanoff, Brad

    2013-02-01

    Falls from heights account for 64% of residential construction worker fatalities and 20% of missed work days. We hypothesized that worker safety would improve with foremen training in fall prevention and safety communication. Training priorities identified through foreman and apprentice focus groups and surveys were integrated into an 8-hour training. We piloted the training with ten foremen employed by a residential builder. Carpenter trainers contrasted proper methods to protect workers from falls with methods observed at the foremen's worksites. Trainers presented methods to deliver toolbox talks and safety messages. Results from worksite observational audits (n=29) and foremen/crewmember surveys (n=97) administered before and after training were compared. We found that inexperienced workers are exposed to many fall hazards that they are often not prepared to negotiate. Fall protection is used inconsistently and worksite mentorship is often inadequate. Foremen feel pressured to meet productivity demands and some are unsure of the fall protection requirements. After the training, the frequency of daily mentoring and toolbox talks increased, and these talks became more interactive and focused on hazardous daily work tasks. Foremen observed their worksites for fall hazards more often. We observed increased compliance with fall protection and decreased unsafe behaviors during worksite audits. Designing the training to meet both foremen's and crewmembers' needs ensured the training was learner-centered and contextually-relevant. This pilot suggests that training residential foremen can increase use of fall protection, improve safety behaviors, and enhance on-the-job training and safety communication at their worksites. Construction workers' training should target safety communication and mentoring skills with workers who will lead work crews. Interventions at multiple levels are necessary to increase safety compliance in residential construction and decrease falls

  3. Mammary Duct Ectasia

    Science.gov (United States)

    ... may worry that it's a sign of breast cancer, especially if you develop a hard lump around a milk duct affected by mammary duct ectasia. While it's important to get signs and symptoms checked out promptly, remember that mammary duct ectasia does not increase your risk of breast cancer. By Mayo ... . Mayo Clinic Footer Legal ...

  4. Incentive mechanism design for the residential building energy efficiency improvement of heating zones in North China

    International Nuclear Information System (INIS)

    Zhong, Y.; Cai, W.G.; Wu, Y.; Ren, H.

    2009-01-01

    Starting with analyzing the investigation results by Ministry of Housing and Urban-Rural Development of China in 2005, more than half of the 10,236 participants are willing to improve the residential building energy efficiency and accept an additional cost of less than 10% of the total cost, the authors illustrate that incenting actions are necessary to improve building energy efficiency and build a central government-local government-market model. As a result of the model analysis, to pursue good execution effects brought by the incentive policies, the executors are required to distinguish the differences of incentive objects' economic activities and strongly respect the incenting on the energy conservation performance. A case study on the incentive policies of existing residential building energy efficiency improvement in heating zones in North China is given as well. Finally, it is strongly recommended to give the first priority to performance-based incentives so that to reduce the lazy behaviors of the incented objects and ensure the targets to be achieved.

  5. Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Dean, J.; VanGeet, O.; Simkus, S.; Eastment, M.

    2012-03-01

    This report outlines the lessons learned and sub-metered energy performance of an ultra low energy single family ranch home and duplex unit, called the Paradigm Pilot Project and presents the final design recommendations for a 153-unit net zero energy residential development called the Josephine Commons Project. Affordable housing development authorities throughout the United States continually struggle to find the most cost-effective pathway to provide quality, durable, and sustainable housing. The challenge for these authorities is to achieve the mission of delivering affordable housing at the lowest cost per square foot in environments that may be rural, urban, suburban, or within a designated redevelopment district. With the challenges the U.S. faces regarding energy, the environmental impacts of consumer use of fossil fuels and the increased focus on reducing greenhouse gas emissions, housing authorities are pursuing the goal of constructing affordable, energy efficient and sustainable housing at the lowest life-cycle cost of ownership. This report outlines the lessons learned and sub-metered energy performance of an ultra-low-energy single family ranch home and duplex unit, called the Paradigm Pilot Project and presents the final design recommendations for a 153-unit net zero energy residential development called the Josephine Commons Project. In addition to describing the results of the performance monitoring from the pilot project, this paper describes the recommended design process of (1) setting performance goals for energy efficiency and renewable energy on a life-cycle cost basis, (2) using an integrated, whole building design approach, and (3) incorporating systems-built housing, a green jobs training program, and renewable energy technologies into a replicable high performance, low-income housing project development model.

  6. Instructor's Manual for Teaching and Practical Courses on Design of Systems and Sizing, Installation and Operation of Systems for Solar Heating and Cooling of Residential Buildings.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    Presented are guidelines for instructors of two courses in the design, installation, and operation of solar heating and cooling systems. These courses are: (1) Design of Systems, and (2) Sizing, Installation, and Operation of Systems. Limited in scope to active solar systems for residential buildings, these courses place primary emphasis upon…

  7. Energy efficient of the residential buildings based climatic condition using experimental design: a case study in malaysia

    Directory of Open Access Journals (Sweden)

    Zahraee Seyed Mojib

    2017-01-01

    Full Text Available In recent years, energy consumption has become a critical issue in the developed and developing countries. Residential buildings are one of the most users of energy in the construction sector that use the highest share of energy. This paper aims at evaluating the effect of four factors that are temperature, humidity, airflow and pressure on the cooling load in the residential buildings. To achieve this goal, statistical experimental design is used to determine the optimum setting of factors that result in optimum energy usage. Simulation software and energy analysis is used to simulate a two-storey building in Malaysia as the case of study. Final results showed that the temperature, humidity and interaction between them have the most significant effect on the energy cooling load. Moreover, to obtain the minimum value of cooling load the temperature and humidity should be equal to A=20 Celsius degree and B=60% respectively. In addition, the other two insignificant factors, airflow and pressure should be placed at the high level which are equal to C=3 cubic meters per hour, and D=6 Pascal (P respectively.

  8. A Cost-Effective Electric Vehicle Charging Method Designed For Residential Homes with Renewable Energy

    Science.gov (United States)

    Lie, T. T.; Liang, Xiuli; Haque, M. H.

    2015-03-01

    Most of the electrical infrastructure in use around the world today is decades old, and may be illsuited to widespread proliferation of personal Electric Vehicles (EVs) whose charging requirements will place increasing strain on grid demand. In order to reduce the pressure on the grid and taking benefits of off peak charging, this paper presents a smart and cost effective EV charging methodology for residential homes equipped with renewable energy resources such as Photovoltaic (PV) panels and battery. The proposed method ensures slower battery degradation and prevents overcharging. The performance of the proposed algorithm is verified by conducting simulation studies utilizing running data of Nissan Altra. From the simulation study results, the algorithm is shown to be effective and feasible which minimizes not only the charging cost but also can shift the charging time from peak value to off-peak time.

  9. Optimal Design and Operation of A Syngas-fuelled SOFC Micro-CHP System for Residential Applications in Different Climate Zones in China

    DEFF Research Database (Denmark)

    Yang, Wenyuan; Liso, Vincenzo; Zhao, Yingru

    2013-01-01

    Energy consumption in residential sector can be considerably reduced by enhancing the efficiency of energy supply. Fuel cell-based residential micro-CHP systems are expected to be one of the most promising technologies because of their high efficiency and low environmental impact. Since the design...... heat-to-power load ratio. Therefore, the aim of this study is to investigate the optimal design and operation of a syngas-fuelled SOFC micro-CHP system for small households located in five different climate zones in China. The ability of the micro-CHP to cover the heat and electricity demand of a 70m2...... single-family household with an average number of occupants of 3 is evaluated. Detailed model of the micro-CHP unit coupled with a hot water storage tank and an auxiliary boiler is developed. A transient model of the hot water storage tank is used to take into account the effect of peak residential heat...

  10. The impact of rate design and net metering on the bill savings from distributed PV for residential customers in California

    International Nuclear Information System (INIS)

    Darghouth, Naim R.; Barbose, Galen; Wiser, Ryan

    2011-01-01

    Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers in the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate. - Highlights: → We examine the value of bill savings under net metering to PV owners in California. → Bill savings per kWh of PV generation varies by a factor of four with net metering. The variation is attributable to rate design, the unique inclining block structure. → The median value of bill savings is reduced by 40-67% with MPR feed-in tariff. → The median value of bill savings is reduced by 6-12% with hourly netting.

  11. Liquid-metal MHD flow in a duct whose cross section changes from a rectangle to a trapezoid, with applications in fusion blanket designs

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.S.

    1986-04-01

    This paper treats the liquid-metal MHD flow in a semi-infinite rectangular duct and a semi-infinite trapezoidal duct, which are connected by a finite-length transition duct. There is a strong, transverse, uniform magnetic field. The walls parallel to the magnetic field (sides) remain parallel, while the walls intersecting the magnetic field are twisted in the transition duct to provide the change in cross sectional shape. The left side has a constant height, while the height of the right side increases or decreases in the transition duct. This geometry gives a skewed velocity profile with a high velocity near the left side, provided the right side is relatively thick. All walls are thin and electrically conducting, but the sides are considerably thicker than the other walls. The application is to fusion-reactor blankets in which a high velocity near the first wall (separating the plasma chamber from the coolant) improves the thermal performance. Junctions of different ducts with walls parallel to the magnetic field are treated for the first time. In expansions, contractions and other geometric transition ducts, as well as in straight ducts with axially varying magnetic fields, the fluid flow and electric currents are concentrated in boundary layers adjacent to the sides and in the side. At a junction with a straight duct with a uniform magnetic field, the flow and current must transfer from the boundary layers adn sides to the core regions. These transfers at junctions play a key role in any three-dimensional flow.

  12. Liquid-metal MHD flow in a duct whose cross section changes from a rectangle to a trapezoid, with applications in fusion blanket designs

    International Nuclear Information System (INIS)

    Walker, J.S.

    1986-04-01

    This paper treats the liquid-metal MHD flow in a semi-infinite rectangular duct and a semi-infinite trapezoidal duct, which are connected by a finite-length transition duct. There is a strong, transverse, uniform magnetic field. The walls parallel to the magnetic field (sides) remain parallel, while the walls intersecting the magnetic field are twisted in the transition duct to provide the change in cross sectional shape. The left side has a constant height, while the height of the right side increases or decreases in the transition duct. This geometry gives a skewed velocity profile with a high velocity near the left side, provided the right side is relatively thick. All walls are thin and electrically conducting, but the sides are considerably thicker than the other walls. The application is to fusion-reactor blankets in which a high velocity near the first wall (separating the plasma chamber from the coolant) improves the thermal performance. Junctions of different ducts with walls parallel to the magnetic field are treated for the first time. In expansions, contractions and other geometric transition ducts, as well as in straight ducts with axially varying magnetic fields, the fluid flow and electric currents are concentrated in boundary layers adjacent to the sides and in the side. At a junction with a straight duct with a uniform magnetic field, the flow and current must transfer from the boundary layers adn sides to the core regions. These transfers at junctions play a key role in any three-dimensional flow

  13. Design, architecture and implementation of a residential energy box management tool in a SmartGrid

    International Nuclear Information System (INIS)

    Ioakimidis, Christos S.; Oliveira, Luís J.; Genikomsakis, Konstantinos N.; Dallas, Panagiotis I.

    2014-01-01

    This paper presents the EB (energy box) concept in the context of the V2G (vehicle-to-grid) technology to address the energy management needs of a modern residence, considering that the available infrastructure includes micro-renewable energy sources in the form of solar and wind power, the electricity loads consist of “smart” and conventional household appliances, while the battery of an EV (electric vehicle) plays the role of local storage. The problem is formulated as a multi-objective DSP (dynamic stochastic programming) model in order to maximize comfort and lifestyle preferences and minimize cost. Combining the DSP model that controls the EB operation with a neural network based approach for simulating the thermal model of a building, a set of scenarios are examined to exemplify the applicability of the proposed energy management tool. The EB is capable of working under real-time tariff and placing bids in electricity markets both as a stand-alone option and integrated in a SmartGrid paradigm, where a number of EBs are managed by an aggregator. The results obtained for the Portuguese tertiary electricity market indicate that this approach has the potential to compete as an ancillary service and sustain business with benefits for both the microgrid and residence occupants. - Highlights: • The energy box is a residential energy management tool in the context of V2G (vehicle-to-grid). • Multi-objective dynamic stochastic programming is used to model the energy box. • The energy box is working under real-time electricity pricing. • The proposed implementation is capable of placing bids in electricity markets. • The results indicate its potential to compete in the Portuguese tertiary market

  14. The Bigger, the Better? The Influence of Urban Green Space Design on Cooling Effects for Residential Areas.

    Science.gov (United States)

    Jaganmohan, Madhumitha; Knapp, Sonja; Buchmann, Carsten M; Schwarz, Nina

    2016-01-01

    It is well known that the cooling effect of an urban green space extends into its surroundings, cooling the immediate environment and mitigating urban heat problems. However, the effects of size, shape, and type of an urban green space on cooling remain uncertain. The objectives of our study were to quantify and compare the strength of the cooling effects of urban parks and forests, to determine how far the cooling effects extend into the surrounding residential environment, and to better understand how temperature gradients are driven by physical characteristics of the green space and the surroundings. Mobile air temperature measurements were performed in 62 urban parks and forests in the city of Leipzig, Germany, in the summer of 2013. Three indicators of cooling were calculated: the change in temperature (ΔT) at the park-width distance, the maximum ΔT, and the cooling distance. The relationships of these variables to the physical characteristics of the green spaces and their surroundings were examined in multiple regression models. Analyzing all three indicators revealed that cooling effects were greater in urban forests than in parks. Cooling increased with increasing size but in a different manner for forests and parks, whereas the influence of shape was the same for forests and parks. Generally, the characteristics of the green spaces were more important than the characteristics of the residential surroundings. These findings have the potential to assist in better planning and designing of urban green spaces to increase their cooling effects. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  15. Exploring the Impact of Commuter’s Residential Location Choice on the Design of a Rail Transit Line Based on Prospect Theory

    Directory of Open Access Journals (Sweden)

    Ding Liu

    2014-01-01

    Full Text Available This paper explores the impact of prospect theory based commuter’s residential location choice on the design problem of a rail transit line located in a monocentric city. A closed-form social welfare maximization model is proposed, with special consideration given to prospect theory based commuter’s residential location choice over years. Commuters are assumed to make residential location choice by a trade-off between daily housing rent and generalized travel cost to minimize their prospect values. The solutions properties of the proposed model are explored and compared analytically. It is found that overestimation exists for the optimal solutions of rail line length, headway, and fare based on traditional utility theory, compared with the optimal solutions of the proposed prospect theory based model. A numerical example is given to illustrate the properties of the proposed model.

  16. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, Dave [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

  17. Residential Interior Design as Complex Composition: A Case Study of a High School Senior's Composing Process

    Science.gov (United States)

    Smagorinsky, Peter; Zoss, Michelle; Reed, Patty M.

    2006-01-01

    This research analyzed the composing processes of one high school student as she designed the interiors of homes for a course in interior design. Data included field notes, an interview with the teacher, artifacts from the class, and the focal student's concurrent and retrospective protocols in relation to her design of home interiors. The…

  18. Solar Ray Tracing Analysis to Determine Energy Availability in a CPC Designed for Use as a Residential Water Heater

    Directory of Open Access Journals (Sweden)

    Miguel Terrón-Hernández

    2018-01-01

    Full Text Available Compound parabolic concentrators are relevant systems used in solar thermal technology. With adequate tailoring, they can be used as an efficient and low-cost alternative in residential water heating applications. This work presents a simulation study using a ray tracing analysis. With this technique, we simulate the interaction between solar rays and solar concentrator to quantify the amount of energy that impinges on the receiver at a particular time. Energy availability is evaluated in a comparison of two configurations throughout the year: static setup at 21° and multi-position setup; tilted with respect to the horizontal, depending on three seasonal positions: 0° for summer, 16° for spring/autumn, and 32° for winter, with the aim to evaluate the amount of available energy in each season. The fact that a tracking system can be dispensed with also represents an economical option for the proposed application. The results showed that at 21°, the proposed solar Compound Parabolic Concentrator (CPC works satisfactorily; however, by carrying out the selected angular adjustments, the overall energy availability increased by 22%, resulting in a more efficient option. The most effective design was also built and analyzed outdoors. The obtained thermal efficiency was of ~43%. The optical design and its evaluation developed herein proved to be a valuable tool for prototype design and performance evaluation.

  19. Design and Analysis of an Optical Coupler for Concentrated Solar Light Using Optical Fibers in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Afshin Aslian

    2016-01-01

    Full Text Available Concentrated sunlight that is transmitted by fiber optics has been used for generating electricity, heat, and daylight. On the other hand, multijunction photovoltaic cells provide high efficiency for generating electricity from highly concentrated sunlight. This study deals with designing and simulating a high-efficiency coupler, employing a mathematical model to connect sunlight with fiber optics for multiple applications. The coupler concentrates and distributes irradiated light from a primary concentrator. In this study, a parabolic dish was used as the primary concentrator, a coupler that contains nine components called a compound truncated pyramid and a cone (CTPC, all of which were mounted on a plate. The material of both the CTPC and the plate was BK7 optical glass. Fiber optics cables and multijunction photovoltaic cells were connected to the cylindrical part of the CTPC. The fibers would transmit the light to the building to provide heat and daylight, whereas multijunction photovoltaic cells generate electricity. Theoretical and simulation results showed high performance of the designed coupler. The efficiency of the coupler was as high as 92%, whereas the rim angle of the dish increased to an optimum angle. Distributed sunlight in the coupler increased the flexibility and simplicity of the design, resulting in a system that provided concentrated electricity, heat, and lighting for residential buildings.

  20. Application analysis of solar total energy systems to the residential sector. Volume III, conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-01

    The objective of the work described in this volume was to conceptualize suitable designs for solar total energy systems for the following residential market segments: single-family detached homes, single-family attached units (townhouses), low-rise apartments, and high-rise apartments. Conceptual designs for the total energy systems are based on parabolic trough collectors in conjunction with a 100 kWe organic Rankine cycle heat engine or a flat-plate, water-cooled photovoltaic array. The ORC-based systems are designed to operate as either independent (stand alone) systems that burn fossil fuel for backup electricity or as systems that purchase electricity from a utility grid for electrical backup. The ORC designs are classified as (1) a high temperature system designed to operate at 600/sup 0/F and (2) a low temperature system designed to operate at 300/sup 0/F. The 600/sup 0/F ORC system that purchases grid electricity as backup utilizes the thermal tracking principle and the 300/sup 0/F ORC system tracks the combined thermal and electrical loads. Reject heat from the condenser supplies thermal energy for heating and cooling. All of the ORC systems utilize fossil fuel boilers to supply backup thermal energy to both the primary (electrical generating) cycle and the secondary (thermal) cycle. Space heating is supplied by a central hot water (hydronic) system and a central absorption chiller supplies the space cooling loads. A central hot water system supplies domestic hot water. The photovoltaic system uses a central electrical vapor compression air conditioning system for space cooling, with space heating and domestic hot water provided by reject heat from the water-cooled array. All of the systems incorporate low temperature thermal storage (based on water as the storage medium) and lead--acid battery storage for electricity; in addition, the 600/sup 0/F ORC system uses a therminol-rock high temperature storage for the primary cycle. (WHK)

  1. Optimization of air ducts for nuclear reactor power generation station

    International Nuclear Information System (INIS)

    Hirao, Katsumi; Yoshino, Hirokazu; Sonoda, Takayuki

    1991-01-01

    In the optimization study on the heating, ventilating and air conditions system in Nuclear Reactor Power Generation Station, proper arrangement of air ducts has been studied using the experimental and analytical investigation from a viewpoint of duct arrangement optimization. This study consists of two parts. Part I is optimization of air ducts in the corridors and Part II is optimization of air duct in each room. In part I, from viewpoints of confinement of radioactive materials in facilities having possible radioactive contamination and improvement of thermal environment for workers, the authors have studied air ducts system in which fresh air is supplied to corridors and heat removal and ventilation for each room are performed by transferring air from the corridors, instead of current ducts system with supply duct to each room. In part II, the condenser room with complex configuration and large space, and the electrical equipment room with simple space are selected for model areas. Based on these studies, experimental and analytical investigation (using a three-dimensional thermal hydraulic analysis) technique has been established, and the effective design method for duct arrangement of HVAC design has been verified for Boiling Water Reactor Power Station. The air-duct arrangements optimized in this study are applied to an Advanced Boiling Water Reactor Power Station in trial and reduction of the air-duct quantity is confirmed

  2. Refurbishment of Residential Buildings : A Design Approach to Energy-Efficiency Upgrades

    NARCIS (Netherlands)

    Konstantinou, T.; Knaack, U.

    Refurbishing the existing building stock is an acknowledged issue in the building industry. Even though awareness has been raised, the design phase of refurbishment projects is often problematic. The decisions taken in the early stages of the design determine the final result; however, the

  3. Mammary Duct Ectasia

    Science.gov (United States)

    ... lumps Mammary duct ectasia Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  4. Ducted fuel injection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Charles J.

    2018-03-06

    Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas with low peak fuel to charge-gas ratios to enable minimal, or no, generation of soot and other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be located proximate to an opening in a tip of a fuel injector. The duct can comprise of one or more holes along its length to enable charge-gas to be drawn into the bore, and further, the duct can cool the fuel and/or charge-gas prior to combustion.

  5. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  6. Design of a Reliable Hybrid (PV/Diesel Power System with Energy Storage in Batteries for Remote Residential Home

    Directory of Open Access Journals (Sweden)

    Vincent Anayochukwu Ani

    2016-01-01

    Full Text Available This paper reports the experience acquired with a photovoltaic (PV hybrid system simulated as an alternative to diesel system for a residential home located in Southern Nigeria. The hybrid system was designed to overcome the problem of climate change, to ensure a reliable supply without interruption, and to improve the overall system efficiency (by the integration of the battery bank. The system design philosophy was to maximize simplicity; hence, the system was sized using conventional simulation tool and representative insolation data. The system includes a 15 kW PV array, 21.6 kWh (3600 Ah worth of battery storage, and a 5.4 kW (6.8 kVA generator. The paper features a detailed analysis of the energy flows through the system and quantifies all losses caused by PV charge controller, battery storage round-trip, rectifier, and inverter conversions. In addition, simulation was run to compare PV/diesel/battery with diesel/battery and the results show that the capital cost of a PV/diesel hybrid solution with batteries is nearly three times higher than that of a generator and battery combination, but the net present cost, representing cost over the lifetime of the system, is less than one-half of the generator and battery combination.

  7. Design, development and testing of a solar-powered multi-family residential size prototype turbocompressor heat pump

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-03-01

    A program described to design, fabricate, and conduct preliminary testing of a prototype solar-powered Rankine cycle turbocompressor heat pump module for a multi-family residential building is presented. A solar system designed to use the turbocompressor heat pump module including all of the subsystems required and the various system operating modes is described in Section I. Section II includes the preliminary design analyses conducted to select the heat pump module components and operating features, working fluid, configuration, size and performance goals, and estimated performance levels in the cooling and heating modes. Section III provides a detailed description of the other subsystems and components required for a complete solar installation. Using realistic performance and cost characteristics for all subsystems, the seasonal performance of the UTC heat pump is described in various US locations. In addition, the estimated energy savings and an assessment of the economic viability of the solar system is presented in Section III. The detailed design of the heat pump module and the arrangement of components and controls selected to conduct the laboratory performance tests are described in Section IV. Section V provides a description of the special laboratory test facility, including the subsystems to simulate the collectors and storage tanks for building load and ambient conditions and the instrumentation, monitoring, and data acquisition equipment. The test results and sample computer analyses and comparisons with predicted performance levels are presented in Section VI. Various appendices provide supplementary and background information concerning working fluid selection (A), configuration selection (B), capacity control concepts (C), building models (D), computer programs used to determine component and system performance and total system economics (E), and weather data (F).

  8. THE EVALUATION SYSTEM OF DESIGN SOLUTIONS FOR RESIDENTIAL PROPERTY ON THE PRE-INVESTMENT STAGE THROUGH NEURAL NETWORK TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    G. D. Kostsikava

    2016-01-01

    Full Text Available Ever since the Soviet Union design solutions were evaluated according to different criteria and indicators. At the present stage of evaluation systems of design solutions stands systemengineering doctrine is allocated. It is complemented by the theory of efficiency and financial sustainability investment project in view of the general market concept. Also great attention is paid to the virtual object modeling. It is urgent to include the behavior prediction of an investment construction project model at each stage of its life cycle. The high cost of all phases of this life cycle makes it necessary to calculate the feasibility of the investment. Very urgent to do it as accurately as possible and before we start of design works on the stage of the investment plan evaluation. Belarus has legislated pre-investment stage of construction project development. To evaluate the design solution at this stage is necessary to develop an investment justification, a project management plan and a business plan. They will evaluate and will compare several options for future objects by the complex. This requires not only time, but considerable financial costs. In order to optimize the process to develop an evaluation system design solutions based on existing projects. It allows the customer (investor choose design solutions to build the object without developing of pre-design documentations for several options. This system it is advisable to try out the example of apartment house building with the assistance of the national fund of project documentation and objects-analogues data bank. The developed evaluation system of design solutions for residential real estate objects in the pre-investment stage is supposed to use the theory of neural networks and neyroprogramming. This system bases on the input parameters projects. The hidden layer neurons are trained to choose suitable projects of apartment houses with their classification. The projects will be classified

  9. Life-cycle cost analysis of energy efficiency design options for residential furnaces and boilers

    International Nuclear Information System (INIS)

    Lutz, James; Lekov, Alex; Chan, Peter; Whitehead, Camilla Dunham; Meyers, Steve; McMahon, James

    2006-01-01

    In 2001, the US Department of Energy (DOE) initiated a rulemaking process to consider whether to amend the existing energy efficiency standards for furnaces and boilers. A key factor in DOE's consideration of new standards is the economic impacts on consumers of possible revisions to energy-efficiency standards. Determining cost-effectiveness requires an appropriate comparison of the additional first cost of energy efficiency design options with the savings in operating costs. DOE's preferred approach involves comparing the total life-cycle cost (LCC) of owning and operating a more efficient appliance with the LCC for a baseline design. This study describes the method used to conduct the LCC analysis and presents the estimated change in LCC associated with more energy-efficient equipment. The results indicate that efficiency improvement relative to the baseline design can reduce the LCC in each of the product classes considered

  10. STANDALONE PHOTOVOLTAIC SYSTEMS SIZING OPTIMIZATION USING DESIGN SPACE APPROACH: CASE STUDY FOR RESIDENTIAL LIGHTING LOAD

    Directory of Open Access Journals (Sweden)

    D. F. AL RIZA

    2015-07-01

    Full Text Available This paper presents a sizing optimization methodology of panel and battery capacity in a standalone photovoltaic system with lighting load. Performance of the system is identified by performing Loss of Power Supply Probability (LPSP calculation. Input data used for the calculation is the daily weather data and system components parameters. Capital Cost and Life Cycle Cost (LCC is calculated as optimization parameters. Design space for optimum system configuration is identified based on a given LPSP value, Capital Cost and Life Cycle Cost. Excess energy value is used as an over-design indicator in the design space. An economic analysis, including cost of the energy and payback period, for selected configurations are also studied.

  11. Curved-Duct

    Directory of Open Access Journals (Sweden)

    Je Hyun Baekt

    2000-01-01

    Full Text Available A numerical study is conducted on the fully-developed laminar flow of an incompressible viscous fluid in a square duct rotating about a perpendicular axis to the axial direction of the duct. At the straight duct, the rotation produces vortices due to the Coriolis force. Generally two vortex cells are formed and the axial velocity distribution is distorted by the effect of this Coriolis force. When a convective force is weak, two counter-rotating vortices are shown with a quasi-parabolic axial velocity profile for weak rotation rates. As the rotation rate increases, the axial velocity on the vertical centreline of the duct begins to flatten and the location of vorticity center is moved near to wall by the effect of the Coriolis force. When the convective inertia force is strong, a double-vortex secondary flow appears in the transverse planes of the duct for weak rotation rates but as the speed of rotation increases the secondary flow is shown to split into an asymmetric configuration of four counter-rotating vortices. If the rotation rates are increased further, the secondary flow restabilizes to a slightly asymmetric double-vortex configuration. Also, a numerical study is conducted on the laminar flow of an incompressible viscous fluid in a 90°-bend square duct that rotates about axis parallel to the axial direction of the inlet. At a 90°-bend square duct, the feature of flow by the effect of a Coriolis force and a centrifugal force, namely a secondary flow by the centrifugal force in the curved region and the Coriolis force in the downstream region, is shown since the centrifugal force in curved region and the Coriolis force in downstream region are dominant respectively.

  12. Rational designing of the internal water supply system in reconstructed residential buildings of mass standard series

    Directory of Open Access Journals (Sweden)

    Orlov Evgeny

    2018-01-01

    Full Text Available The issues of water supply system reconstruction in mass series buildings are reviewed with consideration of water- and resource saving. Principal points for location of plumbing cells in apartments, arrangement of water devices and wastewater receivers, selection of pipelines for reconstructed water line are described. Comparative analysis of design variants of inner water line before and following reconstruction are given. It was found that applying the developed system design approaches the head losses in the inner water supply line will be significantly decreased as well as the water mains length will be decreased with material and installation saving. Based on the data the conclusions on necessity to review standard arrangement solutions of water supply systems in the reconstructed buildings were made. Recommendations on water loss reduction in the system by installation of special water saving fittings on water devices and touchless faucets.

  13. Effect of duct geometry on Wells turbine performance

    International Nuclear Information System (INIS)

    Shaaban, S.; Abdel Hafiz, A.

    2012-01-01

    Highlights: ► A Wells turbine duct design in the form of venturi duct is proposed and investigated. ► Optimum duct geometry is identified. ► Up to 14% increase of the turbine power can be achieved using the optimized duct geometry. ► Up to 9% improve of the turbine efficiency is attained by optimizing the turbine duct geometry. ► The optimized duct geometry results in tangible delay of the turbine stalling point. - Abstract: Wells turbines can represent important source of renewable energy for many countries. An essential disadvantage of Wells turbines is their low aerodynamic efficiency and consequently low power produced. In order to enhance the Wells turbine performance, the present research work proposes the use of a symmetrical duct in the form of a venturi tube with turbine rotor located at throat. The effects of duct area ratio and duct angle are investigated in order to optimize Wells turbine performance. The turbine performance is numerically investigated by solving the steady 3D incompressible Reynolds Averaged Navier–Stocks equation (RANS). A substantial improve of the turbine performance is achieved by optimizing the duct geometry. Increasing both the duct area ratio and duct angle increase the acceleration and deceleration upstream and downstream the rotor respectively. The accelerating flow with thinner boundary layer thickness upstream the rotor reduces the flow separation on the rotor suction side. The downstream diffuser reduces the interaction between tip leakage flow and blade suction side. Up to 14% increase in turbine power and 9% increase in turbine efficiency are achieved by optimizing the duct geometry. On other hand, a tangible delay of the turbine stall point is also detected.

  14. Can the impact on health of a government policy designed to create more liveable neighbourhoods be evaluated? An overview of the RESIDential Environment Project.

    Science.gov (United States)

    Giles-Corti, Billie; Knuiman, Matthew; Pikora, Terri J; Van Neil, Kimberly; Timperio, Anna; Bull, Fiona C L; Shilton, Trevor; Bulsara, Max

    2007-01-01

    There is growing interest in the impact of community design on the health of residents. In 1998, the Western Australian Government began a trial of new subdivision design codes (i.e. Liveable Neighbourhoods Community Design Code) aimed at creating pedestrian-friendly neighbourhoods to increase walking, cycling and public transport use. The trial provided a unique opportunity for a natural experiment to evaluate the impact of a government planning policy on residents. Nevertheless, evaluations of this kind present a number of methodological challenges in obtaining the highest quality evidence possible. This paper describes the RESIDential Environment Project's study design and discusses how various methodological challenges were overcome.

  15. Flow regime analysis of non-Newtonian duct flows

    Science.gov (United States)

    Speetjens, Michel; Rudman, Murray; Metcalfe, Guy

    2006-01-01

    Reoriented duct flows of generalized Newtonian fluids are an idealization of non-Newtonian fluid flow in industrial in-line mixers. Based on scaling analysis and computation we find that non-Newtonian duct flows have several limit behaviors, in the sense that such flows can become (nearly) independent of one or more of the rheological and dynamical control parameters, simplifying the general flow and mixing problem. These limit flows give several levels of modeling complexity to the full problem of non-Newtonian duct flow. We describe the sets of simplified flow models and their corresponding regions of validity. This flow-model decomposition captures the essential rheological and dynamical characteristics of the reoriented duct flows and enables a more efficient and systematic study and design of flow and mixing of non-Newtonian fluids in ducts. Key aspects of the flow-model decomposition are demonstrated via a specific, but representative, duct flow.

  16. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  17. Design and operation of a solar heating and cooling system for a residential size building

    Science.gov (United States)

    Littles, J. W.; Humphries, W. R.; Cody, J. C.

    1978-01-01

    The first year of operation of solar house is discussed. Selected design information, together with a brief system description is included. The house was equipped with an integrated solar heating and cooling system which uses fully automated state-of-the art. Evaluation of the data indicate that the solar house heating and cooling system is capable of supplying nearly 100 percent of the thermal energy required for heating and approximately 50 percent of the thermal energy required to operate the absorption cycle air conditioner.

  18. Greywater Reuse System Design and Economic Analysis for Residential Buildings in Taiwan

    Directory of Open Access Journals (Sweden)

    Yi-Kai Juan

    2016-11-01

    Full Text Available The concept of greywater recycling and reuse has gradually become one of the most important strategies in water stressed countries. Due to a high population density and uneven rainfall distribution, the annual average rainfall distribution per capita in Taiwan is one fifth of the global average, which makes Taiwan a seriously water-stressed country. This study used the unit of a family of four as the target and reexamined the zoning concepts of water usage areas, followed by integrating pipeline configuration, water storage design and a filtering system to propose an Interior Customized Greywater System (ICGS which is based on the application for the family unit. This system can be customized and flexibly adjusted according to household space. In order to verify the feasibility and viability of system, this study performed system configuration and design based on real cases and proposed three scenarios to simulate a 20 year life cycle for cost economic analysis. The result reveals that this system has a minimum payback period of 4 years and provides investment incentives. For regions or countries which have higher water cost or are more water stressed, ICGS can significantly improve the processing and utilization of water.

  19. Building America Case Study: High Performance Ducts in Hot-Dry Climates; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-08-01

    ?Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

  20. Improved Design of Motors for Increased Efficiency in Residential Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Pragasen Pillay

    2008-12-31

    Research progress on understanding magnetic steel core losses is presented in this report. Three major aspects have been thoroughly investigated: 1, experimental characterization of core losses, 2, fundamental physical understanding of core losses and development of core loss formulas, and 3, design of more efficient machine based on the new formulations. Considerable progress has been achieved during the four years of research and the main achievements are summarized in the following: For the experimental characterization, a specially designed advanced commercial test bench was commissioned in addition to the development of a laboratory system with advanced capabilities. The measured properties are core losses at low and higher frequencies, with sinusoidal and non-sinusoidal excitations, at different temperatures, with different measurement apparatus (Toroids, Epstein etc). An engineering-based core loss formula has been developed which considers skin effect. The formula can predict core losses for both sinusoidal and non-sinusoidal flux densities and frequencies up to 4000 Hz. The formula is further tested in electric machines. The formula error range is 1.1% - 7.6% while the standard formulas can have % errors between -8.5% {-+} 44.7%. Two general core loss formulas, valid for different frequencies and thickness, have been developed by analytically and numerically solving Maxwell's equations based on a physical investigation of the dynamic hysteresis effects of magnetic materials. To our knowledge, they are the first models that can offer accurate core loss prediction over a wide range of operating frequencies and lamination thicknesses without a massive experimental database of core losses. The engineering core loss formula has been used with commercial software. The formula performs better than the modified Steinmetz and Bertotti's model used in Cedrat/Magsoft Flux 2D/3D. The new formula shows good correlation with measured results under both

  1. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  2. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  3. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source...

  4. Residential Solar Systems.

    Science.gov (United States)

    Fulkerson, Dan

    This publication contains student and teacher instructional materials for a course in residential solar systems. The text is designed either as a basic solar course or as a supplement to extend student skills in areas such as architectural drafting, air conditioning and refrigeration, and plumbing. The materials are presented in four units…

  5. Bile Duct Exploration

    Science.gov (United States)

    ... 223.2273 Request an Appointment Contact Us Share Facebook Twitter Linkedin Email Bile Duct Exploration Menu Print Full Article Overview Test Details Results and Follow-Up Cleveland Clinic is a non-profit academic medical center. Advertising on our site helps support our mission. We ...

  6. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  7. Choosing the Right Technologies – A Model for Cost Optimized Design of a Renewable Supply System for Residential Zero Energy Buildings

    DEFF Research Database (Denmark)

    Milan, Christian

    , individual performance models are defined. For small scale residential systems the hot water tank is one of the main components, connecting supply and demand side and acting as a buffer during mismatch periods. For this reason, the developed hot water tank model is rather detailed accounting for three......This work presents a methodology to identify and investigate the cost optimal design of supply systems for Low and Net Zero Energy Buildings with the focus on residential single family houses. A preliminary analysis investigating relevant literature and existing computer tools resulted...... different temperature layers, two different supply and demand loops as well as individual heat losses. It is presented at the end of the technology chapter. Subsequently, the methodology is validated by investigating the output with one single technology at a time and thus the individual performance models...

  8. Field investigation of duct system performance in California light commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Delp, W.W.; Matson, N.E.; Tschudy, E. [and others

    1997-12-09

    This paper discusses field measurements of duct system performance in fifteen systems located in eight northern California buildings. Light commercial buildings, one- and two-story with package roof-top HVAC units, make up approximately 50% of the non-residential building stock in the U.S. Despite this fact little is known about the performance of these package roof-top units and their associated ductwork. These simple systems use similar duct materials and construction techniques as residential systems (which are known to be quite leaky). This paper discusses a study to characterize the buildings, quantify the duct leakage, and analyze the performance of the ductwork in these types of buildings. The study tested fifteen systems in eight different buildings located in northern California. All of these buildings had the ducts located in the cavity between the drop ceiling and the roof deck. In 50% of these buildings, this cavity was functionally outside the building`s air and thermal barriers. The effective leakage area of the ducts in this study was approximately 2.6 times that in residential buildings. This paper looks at the thermal analysis of the ducts, from the viewpoint of efficiency and thermal comfort. This includes the length of a cycle, and whether the fan is always on or if it cycles with the cooling equipment. 66% of the systems had frequent on cycles of less than 10 minutes, resulting in non-steady-state operation.

  9. Ducted wind turbines : A potential energy shaper

    NARCIS (Netherlands)

    Dighe, V.V.

    2016-01-01

    In order to harvest wind resources more efficiently and to the greatest extent possible, unconventional wind turbine designs have been proposed, but never gained any acceptance in the marketplace. A team of researchers from TU Delft plans to revisit the concept of ducted wind turbines, which have

  10. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  11. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts and air duct systems....1103 Induction system ducts and air duct systems. (a) Each induction system duct upstream of the first... auxiliary power unit bleed air duct systems, no hazard may result if a duct failure occurs at any point...

  12. Residential energy usage comparison: Findings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, B.A.; Uhlaner, R.T.; Cason, T.N.; Courteau, S. (Quantum Consulting, Inc., Berkeley, CA (United States))

    1991-08-01

    This report presents the research methods and results from the Residential Energy Usage Comparison (REUC) project, a joint effort by Southern California Edison Company (SCE) and the Electric Power Research Institute (EPRI). The REUC project design activities began in early 1986. The REUC project is an innovative demand-site project designed to measure and compare typical energy consumption patterns of energy efficient residential electric and gas appliances. 95 figs., 33 tabs.

  13. Technology Solutions Case Study: Raised Ceiling Interior Duct System, New Smyrna, Florida

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-09-01

    Builder S.E. Volusia County Habitat for Humanity (SEVHFH) was interested in constructing a home to the new U.S. Department of Energy (DOE) Zero Energy Ready Home standards. SEVHFH partners with DOE team Building America Partnership for Improved Residential Construction on Habitat for Humanity homes and routinely builds to ENERGY STAR V3.1. The only modification to the design needed to comply with the Zero Energy Ready Home criteria was the interior duct requirement. Unwilling to incur the added costs of a foam roof deck or wall heights that exceed 8 ft to accommodate a fur-down chase, SEVHFH opted to build a fur-up or raised ceiling chase. This case study describes the project.

  14. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  15. DESIGN SOLUTIONS FOR THERMAL INSULATION OF EXTERIOR WALLS OF CAST-IN-PLACE CONCRETE HIGH-RISE RESIDENTIAL BUILDINGS IN CENTRAL REGIONS OF СHINA

    Directory of Open Access Journals (Sweden)

    Bantserova Ol'ga Leonidovna

    2012-12-01

    Full Text Available A significant portion of the overall heat loss is due to the heat loss through the building envelope. According to the opinions of experts, the surface area of exterior walls has the insulation of about 65 % of the total envelope of apartment buildings; therefore, thermal protection of external walls of buildings is a key issue in ensuring the thermal performance of envelopes of apartment buildings. The author has developed design solutions that assure the thermal protection of exterior walls and that are aimed at identifying the optimal solution in terms of the location of insulation materials, their thermal performance and insulation of exterior walls of apartment buildings in central regions of China. The author presents a comparative analysis of the main methodologies of thermal insulation designated for the exterior walls of multi-storey residential buildings: internal and external insulation, as well as the insulation in-between the wall layers. The analyses of wall designs are based on the insulation performance, thermal insulation performance, methods of mounting different systems of insulation, and cost of work. As a result, practical recommendations originate from the statement that the most optimal designs of exterior walls of monolithic high-rise apartment buildings of central regions of China are those that have insulation on the outside of the building. They include layers of insulation made of extruded polystyrene, which is currently planned for use in the construction of high-rise monolithic residential buildings in central China.

  16. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  17. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  18. An optimization methodology for the design of renewable energy systems for residential net zero energy buildings with on-site heat production

    DEFF Research Database (Denmark)

    Milan, Christian; Bojesen, Carsten; Nielsen, Mads Pagh

    2011-01-01

    The concept of net zero energy buildings (NZEB) has received increased attention throughout the last years. A well adapted and optimized design of the energy supply system is crucial for the performance of such buildings. This paper aims at developing a method for the optimal sizing of renewable...... energy supply systems for residential NZEB involving on-site production of heat and electricity in combination with electricity exchanged with the public grid. The model is based on linear programming and determines the optimal capacities for each relevant supply technology in terms of the overall system...

  19. Duct having oscillatory side wall

    Energy Technology Data Exchange (ETDEWEB)

    Sprouse, Kenneth M.

    2018-04-03

    A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.

  20. 46 CFR 116.610 - Ventilation ducts.

    Science.gov (United States)

    2010-10-01

    ... served by the ventilation duct for shutting off the passage of air through the ventilation duct in the... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation ducts. 116.610 Section 116.610 Shipping... Ventilation § 116.610 Ventilation ducts. (a) For the purposes of this section, a ventilation duct includes any...

  1. DESIGN EXPERIMENT WITH SOLAR ENERGY IN THE ELABORATION OF 25-STOREY RESIDENTIAL COMPLEX FOR THE CRIMEA DISTRICT OF THE SEVASTOPOL CITY

    Directory of Open Access Journals (Sweden)

    Kovaleva Alesya Sergeevna

    2016-09-01

    Full Text Available The scientific project examines the issues of energy efficiency, renewable energy sources, as well as ecology. In today's world the ecological issues are more current than ever. Some of them are ozone holes, disappearance of many species of animals and plants, exhaustible fuel reserves. Ecology is a huge problem of our civilization, which may be solved by paying more attention to energy efficiency in the process of urban development. In the implementation of energy efficiency experiments it is necessary to involve the efforts of scientists, politicians, non-governmental organizations, but first and foremost — of inventors, architects and designers. Energy efficiency in civil construction is presented in the article as an area allowing us to find design solutions basing on renewable energy sources, in particular photocell energy. Project experiment data on a residential high-rise complex in the city of Sevastopol is considered. The author presents design calculations and the comparison of the variants of design decisions on the use of photovoltaic cells producing energy to illuminate the underground car park of a residential high-rise complex. In the future, the use of photovoltaic cells as cladding structures may change the energy characteristics of buildings in case of transition to production scale implementation of the technology. This makes it possible to consider the prospects of urban development growth and improvement of the economy of the construction of expensive facilities. However, subsequent design experiments should be based mostly on other types of facilities and should take into account the impact of wind and aerodynamic performance of buildings in case of application of photovoltaic cells on roofs and facades. The results of the design experiment allow initially investigating the regularities of urban conditions and the amount of energy produced by building surfaces. Thus, the provided concept and the design experiment can be

  2. Optimal design and operation of a syngas-fuelled SOFC micro CHP system for residential applications in different climate zones in China

    DEFF Research Database (Denmark)

    Yang, Wenyuan; Zhao, Yingru; Liso, Vincenzo

    2014-01-01

    of the micro-CHP to cover the heat and electricity demand of a 70 m2 single-family apartment with an average number of occupants of 3 is evaluated. A detailed model of the micro-CHP unit coupled with a hot water storage tank and an auxiliary boiler is developed. System design trade-offs are discussed......Fuel cell based micro-CHP systems are expected to be one of the most promising technologies for implementation in the residential sector. Since the design and operation of such CHP systems are greatly dependent upon the seasonal atmospheric conditions, it is important to evaluate their performance...... under difference climate conditions to ensure that it is well matched with the local heat-to-power ratio. The aim of this study is to investigate the optimal design and operation of a syngas-fuelled SOFC micro-CHP system for small households located in five different climate zones in China. The ability...

  3. [Design and validation of a satisfaction and quality of life scale for users of residential and social care centres].

    Science.gov (United States)

    Literas, Luciano; Navarro, Albert; Fontanals, María Dulce

    2010-01-01

    In a comprehensive approach to ageing care, the promotion of personal and emotional well-being is fundamental, as well as the development of tools to evaluate outcomes. This approach needs to take into account the subjective perception of the elderly by gathering evidence using indicators that express impacts and satisfaction. Thus, the SAR Foundation's Satisfaction and Quality of Life Scale (SyCV-FSAR) has been developed and validated to assess well-being in residential care settings. Bibliographical reviews, interviews and focal groups with professionals (doctors, nurses, social workers, quality managers, etc.) were conducted to define the questionnaire that was first piloted and then applied in a final survey. Test of validity was carried out by factorial analysis (FA), principal axis factoring and Oblimin rotation. The sampling adequacy was measured by Kaiser-Meyer-Olkin test and Bartlett's sphericity. Test of reliability was carried out by internal consistency analysis (Cronbach's alpha). A total of 475 users took part in the survey, 69.1% of those who fulfilled the criteria. Of these 60.0% were women, an average age 82.1, 47.2% of them between 75 and 84 years old, with a MMSE of 27. The FA identified three factors ("Residential service and geriatric care", "Personal framework" and "Social relationships") that explained 27.5% of the total variability. The measure of sampling adequacy by Kaiser-Meyer-Olkin test was 0.80, and the Bartlett's sphericity test was significant (P<0.001). The global α Cronbach was 0.82. According to the results obtained in the study we can conclude that the SyCV-FSAR Scale is a reliable, simple and easy-to-apply tool, which gathers the users' perception on key aspects of daily life in residential and social care centres. Copyright © 2009 SEGG. Published by Elsevier Espana. All rights reserved.

  4. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct....1103 Induction systems ducts and air duct systems. (a) Each induction system duct upstream of the first... it might cause a fire hazard. (b) Each duct must be strong enough to prevent induction system failure...

  5. Intrahepatic transposition of bile ducts.

    Science.gov (United States)

    Delić, Jasmin; Savković, Admedina; Isaković, Eldar; Marković, Sergije; Bajtarevic, Alma; Denjalić, Amir

    2012-01-01

    Objective. To describe the intrahepatic bile duct transposition (anatomical variation occurring in intrahepatic ducts) and to determine the frequency of this variation. Material and Methods. The researches were performed randomly on 100 livers of adults, both sexes. Main research methods were anatomical macrodissection. As a criterion for determination of variations in some parts of bile tree, we used the classification of Segmentatio hepatis according to Couinaud (1957) according to Terminologia Anatomica, Thieme Stuugart: Federative Committee on Anatomical Terminology, 1988. Results. Intrahepatic transposition of bile ducts was found in two cases (2%), out of total examined cases (100): right-left transposition (right segmental bile duct, originating from the segment VIII, joins the left liver duct-ductus hepaticus sinister) and left-right intrahepatic transposition (left segmental bile duct originating from the segment IV ends in right liver duct-ductus hepaticus dexter). Conclusion. Safety and success in liver transplantation to great extent depends on knowledge of anatomy and some common embryological anomalies in bile tree. Variations in bile tree were found in 24-43% of cases, out of which 1-22% are the variations of intrahepatic bile ducts. Therefore, good knowledge on ductal anatomy enables good planning, safe performance of therapeutic and operative procedures, and decreases the risk of intraoperative and postoperative complications.

  6. Propagation of sound waves in ducts

    DEFF Research Database (Denmark)

    Jacobsen, Finn

    2000-01-01

    Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described.......Plane wave propagation in ducts with rigid walls, radiation from ducts, classical four-pole theory for composite duct systems, and three-dimentional waves in wave guides of various cross-sectional shape are described....

  7. Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2016-01-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.

  8. Investigate and Comparsion Self-Esteem and Happiness Among Residential and Non-Residential Old People

    Directory of Open Access Journals (Sweden)

    Zakieh Nasiri

    2012-07-01

    Full Text Available Objectives: The main aim of this study was to investigate and to compare elderly happiness and self-esteem among residential and non-residential. Methods & Materials: This research was designed as descriptive. Two groups were selected in convenience method. Member of residential elderly (416 elderly were chosen based on Morgan Table. Hundred-twenty elderly, 60 residential (30 men and 30 women and 60 non-residential (30 men and 30 women were chosen for study. Data used the three questionnaires, like Demographic questionnaires, Oxford Happiness Inventory and Self-esteem Scale’s Rozenberg. Data were gathered and analyzed with Pearson test, t-student test. Results: The results were indicated that a significant relationship between happiness and self-esteem, among residential and non- residential old people. The findings showed significant difference in happiness, self-esteem among residential and home participants in both groups (P<0.01. Conclusion: The results were showed that a significant relationship between social support and self-esteem, among residential and non-residential old people. Also, the results were indicated that significant difference between social support. In general, residential participants had lower social support and self-esteem than non-residential participants.

  9. Effect of Modifications to Induction System on Altitude Performance of V-1710-93 Engine III : Use of Parabolic Rotating Guide Vanes and NACA Designed Auxiliary-stage Inlet Elbow and Interstage Duct

    Science.gov (United States)

    Standahar, Ray M; Mccarty, James S

    1947-01-01

    Bench runs of a modified V-1710-93 engine equipped with a two-stage supercharger, interstage carburetor, aftercooler assembly, and backfire screens have been made at a simulated altitude of 29,000 feet to determine the effect of several induction-system modifications on the engine and supercharger performance. The standard guide vanes on the auxiliary- and engine-stage superchargers were replaced by rotating guide vanes with a parabolic blade profile. The auxiliary-stage inlet elbow and interstage duct were replaced with new units of NACA design. These modifications were made one at a time and data were obtained after each change to determine the effect of each modification. All runs were made at a constant engine speed of 3000 rpm at a simulated altitude of 29,000 feet and all changes in engine power were made by varying the speed of the auxiliary-stage supercharger.

  10. Designing, building, and testing a solar thermoelectric generation, STEG, for energy delivery to remote residential areas in developing regions

    Science.gov (United States)

    Moumouni, Yacouba

    New alternatives and inventive renewable energy techniques which encompass both generation and power management solutions are fundamental for meeting remote residential energy supply and demand today, especially if the grid is quasi-inexistent. Solar thermoelectric generators can be a cost-effective alternative to photovoltaics for a remote residential household power supply. A complete solar thermoelectric energy harvesting system is presented for energy delivery to remote residential areas in developing regions. To this end, the entire system was built, modeled, and then validated with LTspice simulator software via thermal-to-electrical analogy schemes. Valuable data in conjunction with two novel LTspice circuits were obtained, showing the achievability of analyzing transient heat transfer with the Spice simulator. Hence, the proposed study begins with a comprehensive method of extracting thermal parameters that appear in thermoelectric modules. A step-by-step procedure was developed and followed to succinctly extract parameters, such as the Seebeck coefficient, electrical conductivity, thermal resistance, and thermal conductivity needed to model the system. Data extracted from datasheet, material properties, and geometries were successfully utilized to compute the thermal capacities and resistances necessary to perform the analogy. In addition, temperature variations of the intrinsic internal parameters were accounted for in this process for accuracy purposes. The steps that it takes to simulate any thermo-electrical system with the LTspice simulator are thoroughly explained in this work. As a consequence, an improved Spice model for a thermoelectric generator is proposed. Experimental results were compiled in the form of a lookup table and then fed into the Spice simulator using the piecewise linear (PWL) command in order to validate the model. Experimental results show that a temperature differential of 13.43°C was achievable whereas the simulation indicates

  11. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States); Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States)

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  12. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, Eric [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, Danny [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWHs) on space conditioning and water heating energy use in residential applications. Two identical HPWHs, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  13. Salivary duct carcinoma.

    Science.gov (United States)

    D'heygere, Emmanuel; Meulemans, Jeroen; Vander Poorten, Vincent

    2018-01-25

    The review puts new information on geno- and phenotype of salivary duct carcinoma (SDC) in the perspective of the updated 2017 WHO classification. The proportion of SDC is increasing. This may be because of a true rise in incidence, but certainly to better diagnostic tests and changed WHO definitions. In this light, a substantial proportion of carcinoma expleomorphic adenoma is now attributed to the category of SDC. 'Low-grade SDC' and 'SDC in-situ' of the former WHO classification, are now named low-grade and high-grade intraductal carcinoma (IDC), respectively. Recent series quantify biologic aggressiveness: perineural growth, vascular invasion, and extracapsular extension in lymph node metastasis are each observed in two out of three patients with SDC. Most patients die within 3 years, but once 5-year disease-free survival is reached, further disease activity is exceptional. The typical molecular biological profile with high human epidermal growth factor receptor 2 and androgen receptor expression is increasingly successfully exploited in clinical trials for advanced SDC. The aggressive SDC is increasingly diagnosed. Despite intensive combined surgery and radiation therapy, many patients recur, for whom new bullets, targeting the molecular biological mechanisms, are the subject of ongoing clinical trials.

  14. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  15. The Design of New Technology Supporting Wellbeing, Independence and Social Participation, for Older Adults Domiciled in Residential Homes and/or Assisted Living Communities

    Directory of Open Access Journals (Sweden)

    Joan Cahill

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to identify and validate the requirements for new technology supporting wellness, independence and social participation for older people domiciled in residential homes and/or assisted-living communities. Method: This research adopts a stakeholder evaluation approach to requirements elicitation and user interface design. Specifically, the study design combines several qualitative human–machine interaction (HMI design frameworks/methods, including realist ethnography, scenario-based design, persona-based design, and participatory design. Findings: New technology should reflect positive values around ageing and link to psychosocial models of successful ageing, and biopsychosocial models of health and wellbeing. Resident autonomy, wellness and social participation cannot be conceptualized outside an understanding of the relationships older adults have with others. The design remit for this technology is to enable a resident experience that is similar to living at home. New technologies should facilitate wellness and communication/connection, and not simply risk assessment. New technology provides an opportunity to bridge existing information gaps between care planning, care assessments and daily care. Overall this technology needs to be intuitive and uphold the resident’s dignity and rights. Person-to-person interaction is central to care delivery. The introduction of new technology should enhance this interaction, and not threaten it. Conclusions: Future assisted-living (AL technology should be premised by biopsychosocial models of wellness and support relationships between older adults and members of the personal and professional community. New assisted-living technology affords the possibility for improved social relationships, enhanced wellbeing, better quality of care, and independence. Such technologies require careful consideration in relation to adapting to age/condition and managing issues

  16. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  17. Error analysis for duct leakage tests in ASHRAE standard 152P

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.

    1997-06-01

    This report presents an analysis of random uncertainties in the two methods of testing for duct leakage in Standard 152P of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The test method is titled Standard Method of Test for Determining Steady-State and Seasonal Efficiency of Residential Thermal Distribution Systems. Equations have been derived for the uncertainties in duct leakage for given levels of uncertainty in the measured quantities used as inputs to the calculations. Tables of allowed errors in each of these independent variables, consistent with fixed criteria of overall allowed error, have been developed.

  18. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three-dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k-∊ turbulence model of three-dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  19. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    Directory of Open Access Journals (Sweden)

    Xiao-bo Lai

    2011-11-01

    Full Text Available The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the computational fluid dynamics (CFD theories adopted; a three‐dimensional fluid model of the duct is established by means of the FLUENT solver of the CFD software. Secondly, with the k‐ε turbulence model of three‐ dimensional incompressible fluid considered and the PRISO pressure modification algorithm employed, the flow field numerical simulations inside the duct of the robot vacuum cleaner are carried out. Then, the velocity vector plots on the arbitrary plane of the duct flow field are obtained. Finally, an investigation of the dynamic characteristics of the duct flow field is done and defects of the original duct flow field are analysed, the optimisation of the original flow field has then been conducted. Experimental results show that the duct flow field after optimisation can effectively reduce pressure drop, the feasibility as well as the correctness of the theoretical modelling and optimisation approaches are validated.

  20. East Meets West--An Introduction to the Design of Residential Interiors in Contemporary Asian Countries. Asian Studies Module.

    Science.gov (United States)

    Hagan, Kay

    This curriculum module presents information for an introductory course designed to develop a cross-cultural awareness and appreciation of the rich opportunities for growth in interior design and related fields that has resulted from the expansion of the global marketplace. First, the instructional goals of the course are outlined, suggesting that…

  1. Research on Duct Flow Field Optimisation of a Robot Vacuum Cleaner

    OpenAIRE

    Lai, Xiao-bo; Wang, Hai-shun; Liu, Hua-shan

    2011-01-01

    The duct of a robot vacuum cleaner is the length of the flow channel between the inlet of the rolling brush blower and the outlet of the vacuum blower. To cope with the pressure drop problem of the duct flow field in a robot vacuum cleaner, a method based on Pressure Implicit with Splitting of Operators (PRISO) algorithm is introduced and the optimisation design of the duct flow field is implemented. Firstly, the duct structure in a robot vacuum cleaner is taken as a research object, with the...

  2. Conservation Value of Residential Open Space: Designation and Management Language of Florida’s Land Development Regulations

    Directory of Open Access Journals (Sweden)

    Dara M. Wald

    2010-06-01

    Full Text Available The conservation value of open space depends upon the quantity and quality of the area protected, as well as how it is designed and managed. This study reports the results of a content analysis of Florida county Land Development Regulations. Codes were reviewed to determine the amount of open space required, how open space is protected during construction, the delegation of responsibilities, and the designation of funds for management. Definitions of open space varied dramatically across the state. Most county codes provided inadequate descriptions of management recommendations, which could lead to a decline in the conservation value of the protected space.

  3. Design and construction of a two dimensional duct equipped with a wave generator and a variable coastal slope and an ocean wave energy conversion system (OWC)

    OpenAIRE

    Tabei, Amir Hossein

    2009-01-01

    The aims of this thesis were evaluation the type of wave channel, wave current, and effect of some parameters on them and identification and comparison between types of wave maker in laboratory situations. In this study, designing and making of two dimension channels (flume) and wave maker for experiment son the marine buoy, marine building and energy conversion systems were also investigated. In current research, the physical relation between pump and pumpage and the designing of current mak...

  4. Practical Diagnostics for Evaluating Residential Commissioning Metrics

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig; Walker, Iain; Siegel, Jeff; Sherman, Max

    2002-06-11

    In this report, we identify and describe 24 practical diagnostics that are ready now to evaluate residential commissioning metrics, and that we expect to include in the commissioning guide. Our discussion in the main body of this report is limited to existing diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. Appendix C describes the 83 other diagnostics that we have examined in the course of this project, but that are not ready or are inappropriate for residential commissioning. Combined with Appendix B, Table 1 in the main body of the report summarizes the advantages and disadvantages of all 107 diagnostics. We first describe what residential commissioning is, its characteristic elements, and how one might structure its process. Our intent in this discussion is to formulate and clarify these issues, but is largely preliminary because such a practice does not yet exist. Subsequent sections of the report describe metrics one can use in residential commissioning, along with the consolidated set of 24 practical diagnostics that the building industry can use now to evaluate them. Where possible, we also discuss the accuracy and usability of diagnostics, based on recent laboratory work and field studies by LBNL staff and others in more than 100 houses. These studies concentrate on evaluating diagnostics in the following four areas: the DeltaQ duct leakage test, air-handler airflow tests, supply and return grille airflow tests, and refrigerant charge tests. Appendix A describes those efforts in detail. In addition, where possible, we identify the costs to purchase diagnostic equipment and the amount of time required to conduct the diagnostics. Table 1 summarizes these data. Individual equipment costs for the 24

  5. The statistical evaluation of duct tape end match as physical evidence

    Science.gov (United States)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  6. Thoracic duct lymphography by subcutaneous contrast agent ...

    African Journals Online (AJOL)

    A second lymphography revealed a collateral thoracic duct that was not detected during the first lymphography. The collateral duct was ligated and chylothorax was resolved after the second surgery. The lymphography applied in this study was minimally-invasive and easily provided images of the thoracic duct in a dog with ...

  7. Studying feasibility and effects of a two-stage nursing staff training in residential geriatric care using a 30 month mixed-methods design [ISRCTN24344776

    Directory of Open Access Journals (Sweden)

    Hantikainen Virpi

    2011-05-01

    Full Text Available Abstract Background Transfer techniques and lifting weights often cause back pain and disorders for nurses in geriatric care. The Kinaesthetics care conception claims to be an alternative, yielding benefits for nurses as well as for clients. Starting a multi-step research program on the effects of Kinaesthetics, we assess the feasibility of a two-stage nursing staff training and a pre-post research design. Using quantitative and qualitative success criteria, we address mobilisation from the bed to a chair and backwards, walking with aid and positioning in bed on the staff level as well as on the resident level. In addition, effect estimates should help to decide on and to prepare a controlled trial. Methods/Design Standard basic and advanced Kinaesthetics courses (each comprising four subsequent days and an additional counselling day during the following four months are offered to n = 36 out of 60 nurses in a residential geriatric care home, who are in charge of 76 residents. N = 22 residents needing movement support are participating to this study. On the staff level, measurements include focus group discussions, questionnaires, physical strain self-assessment (Borg scale, video recordings and external observation of patient assistance skills using a specialised instrument (SOPMAS. Questionnaires used on the resident level include safety, comfort, pain, and level of own participation during mobilisation. A functional mobility profile is assessed using a specialised test procedure (MOTPA. Measurements will take place at baseline (T0, after basic training (T1, and after the advanced course (T2. Follow-up focus groups will be offered at T1 and 10 months later (T3. Discussion Ten criteria for feasibility success are established before the trial, assigned to resources (missing data, processes (drop-out of nurses and residents and science (minimum effects criteria. This will help to make rational decision on entering the next stage of the research

  8. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  9. College residential sleep environment.

    Science.gov (United States)

    Sexton-Radek, Kathy; Hartley, Andrew

    2013-12-01

    College students regularly report increased sleep disturbances as well as concomitant reductions in performance (e.g., academic grades) upon entering college. Sleep hygiene refers to healthy sleep practices that are commonly used as first interventions in sleep disturbances. One widely used practice of this sort involves arranging the sleep environment to minimize disturbances from excessive noise and light at bedtime. Communal sleep situations such as those in college residence halls do not easily support this intervention. Following several focus groups, a questionnaire was designed to gather self-reported information on sleep disturbances in a college population. The present study used The Young Adult Sleep Environment Inventory (YASEI) and sleep logs to investigate the sleep environment of college students living in residential halls. A summary of responses indicated that noise and light are significant sleep disturbances in these environments. Recommendations are presented related to these findings.

  10. Plasma transport in magnetic duct filter

    International Nuclear Information System (INIS)

    Zhang Tao; Chu, Paul K; Fu, Ricky K Y; Brown, Ian G

    2002-01-01

    A cathodic arc plasma source equipped with a curved magnetic duct to filter macro-particles was used to study plasma transport through the duct. The optimal duct bias, at which the magnetic duct produces the maximum plasma output, for titanium cathodic arc plasma at 50, 100 and 150 A arc current was determined and the parametric effects of the arc current and guiding magnetic field on the optimal duct bias were investigated. The optimal bias decreased as the guiding magnetic field increased from 100 to 400 G and was almost independent of the guiding magnetic field when it was between 400 and 600 G, the upper limit for our equipment. The optimal duct bias at 400 G guiding magnetic field decreased with increasing arc current. Our results indicate that the optimal duct bias is related not only to the structure of the plasma source, but is also influenced by many other factors including cathode material and other plasma properties

  11. Application of a finite element method for computing grazing incidence wave structure in an impedance tube - Comparison with experiment. [for duct liner aeroacoustic design

    Science.gov (United States)

    Lester, H. C.; Parrott, T. L.

    1979-01-01

    The acoustic performance of a liner specimen, in a grazing incidence impedance tube, is analyzed using a finite element method. The liner specimen was designed to be a locally reacting, two-degree-of-freedom type with the resistance and reactance provided by perforated facesheets and compartmented cavities. Measured and calculated wave structures are compared for both normal and grazing incidence from 0.3 to 1.2 kHz. A finite element algorithm was incorporated into an optimization loop in order to predict liner grazing incidence impedance from measured SWR and null position data. Results suggest that extended reaction effects may have been responsible for differences between normal and grazing incidence impedance estimates.

  12. An intervention strategy for improving residential environment and positive mental health among public housing tenants: rationale, design and methods of Flash on my neighborhood!

    Science.gov (United States)

    Houle, Janie; Coulombe, Simon; Radziszewski, Stephanie; Leloup, Xavier; Saïas, Thomas; Torres, Juan; Morin, Paul

    2017-09-25

    In Canada, public housing programs are an important part of governmental strategies to fight poverty and public exclusion. The Flash on my neighborhood! project is a four-year multiphase community-based participatory action research strategy currently implemented in six public housing developments (n = 1009 households) across the province of Québec, Canada. The goal is to reduce the mental health disparities faced by these public housing tenants compared to the general population, while identifying which environmental and policy changes are needed to turn public housing settings into healthier environments. The protocol involves three successive, interconnected phases: 1) Strengths and needs assessment, including community outreach and recruitment of tenants to collaborate as peer researchers, an exploratory qualitative component (photovoice), a systematic neighborhood observation, and a household survey; 2) Action plan development, including a community forum and interactive capacity-building and discussion sessions; 3) Action plan implementation and monitoring. The entire intervention is evaluated using a mixed-method design, framed within a multiple case study perspective. Throughout the project and particularly in the evaluation phase, data will be collected to record a) contextual factors (tenants' previous experience of participation, history of public housing development, etc.); b) activities that took place and elements from the action plan that were implemented; and c) short- and medium-term outcomes (objective and perceived improvements in the quality of the residential setting, both physically and in terms of mental health and social capital). The study will provide unprecedented evidence-based information on the key ingredients of a collective intervention process associated with the increased collective empowerment and positive mental health of public housing tenants.

  13. An intervention strategy for improving residential environment and positive mental health among public housing tenants: rationale, design and methods of Flash on my neighborhood!

    Directory of Open Access Journals (Sweden)

    Janie Houle

    2017-09-01

    Full Text Available Abstract Background In Canada, public housing programs are an important part of governmental strategies to fight poverty and public exclusion. The Flash on my neighborhood! project is a four-year multiphase community-based participatory action research strategy currently implemented in six public housing developments (n = 1009 households across the province of Québec, Canada. The goal is to reduce the mental health disparities faced by these public housing tenants compared to the general population, while identifying which environmental and policy changes are needed to turn public housing settings into healthier environments. Methods The protocol involves three successive, interconnected phases: 1 Strengths and needs assessment, including community outreach and recruitment of tenants to collaborate as peer researchers, an exploratory qualitative component (photovoice, a systematic neighborhood observation, and a household survey; 2 Action plan development, including a community forum and interactive capacity-building and discussion sessions; 3 Action plan implementation and monitoring. The entire intervention is evaluated using a mixed-method design, framed within a multiple case study perspective. Throughout the project and particularly in the evaluation phase, data will be collected to record a contextual factors (tenants’ previous experience of participation, history of public housing development, etc.; b activities that took place and elements from the action plan that were implemented; and c short- and medium-term outcomes (objective and perceived improvements in the quality of the residential setting, both physically and in terms of mental health and social capital. Discussion The study will provide unprecedented evidence-based information on the key ingredients of a collective intervention process associated with the increased collective empowerment and positive mental health of public housing tenants.

  14. Building America Case Study: Effect of Ducted HPWH on Space Conditioning and Water Heating Energy Use - Central Florida Lab Home, Cocoa, Florida

    Energy Technology Data Exchange (ETDEWEB)

    C. Colon, E. Martin, and D. Parker

    2017-04-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  15. Design of Residential Photovoltaic Systems

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2017-01-01

    Renewable energy has become very important both worldwide and on the European market, mainly due to the decrease in the photovoltaic (PV) system cost (up to 75%) during the last decade. PV installations worldwide have reached 227 GW at the end of 2015 with a predicted extra 50 GW of new installat...

  16. Verification of the DUCT-III for calculation of high energy neutron streaming

    Energy Technology Data Exchange (ETDEWEB)

    Masukawa, Fumihiro; Nakano, Hideo; Nakashima, Hiroshi; Sasamoto, Nobuo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tayama, Ryu-ichi; Handa, Hiroyuki; Hayashi, Katsumi [Hitachi Engineering Co., Ltd., Hitachi, Ibaraki (Japan); Hirayama, Hideo [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan); Shin, Kazuo [Kyoto Univ., Kyoto (Japan)

    2003-03-01

    A large number of radiation streaming calculations under a variety of conditions are required as a part of shielding design for a high energy proton accelerator facility. Since sophisticated methods are very time consuming, simplified methods are employed in many cases. For accuracy evaluation of a simplified code DUCT-III for high energy neutron streaming calculations, two kinds of benchmark problems based on the experiments were analyzed. Through comparison of the DUCT-III calculations with both the measurements and the sophisticated Monte Carlo calculations, DUCT-III was seen reliable enough for applying to the shielding design for the Intense Proton Accelerator Facility. (author)

  17. Experimental study on the particles deposition in the sampling duct

    Energy Technology Data Exchange (ETDEWEB)

    Vendel, J.; Charuau, J. [Institut de Protection et de Surete Nucleaire, Yvette (France)

    1995-02-01

    A high standard of protection against the harmful effects of radioactive aerosol dissemination requires a measurement, as representative as possible, of their concentration. This measurement depends on the techniques used for aerosol sampling and transfer to the detector, as well as on the location of the latter with respect to the potential sources. The aeraulic design of the apparatus is also an important factor. Once collected the aerosol particles often have to travel through a variably shaped duct to the measurement apparatus. This transport is responsible for losses due to the particles deposition on the walls, leading to a distortion on the concentration measurements and a change in the particle size distribution. To estimate and minimize measurement errors it is important to determine the optimal transport conditions when designing a duct; its diameter and material, the radius of curvature of the bends and the flow conditions must be defined in particular. This paper presents an experimental study in order to determine, for each deposition mechanism, the retained fraction, or the deposition velocity for different flow regimes. This study has pointed out that it exists a favourable flow regime for the particle transport through the sampling ducts (2 500 < Re < 5 000). It has been established, for any particle diameters, equations to predict the aerosol penetration in smooth-walled cylindrical metal ducts.

  18. Experimental study on the particles deposition in the sampling duct

    International Nuclear Information System (INIS)

    Vendel, J.; Charuau, J.

    1995-01-01

    A high standard of protection against the harmful effects of radioactive aerosol dissemination requires a measurement, as representative as possible, of their concentration. This measurement depends on the techniques used for aerosol sampling and transfer to the detector, as well as on the location of the latter with respect to the potential sources. The aeraulic design of the apparatus is also an important factor. Once collected the aerosol particles often have to travel through a variably shaped duct to the measurement apparatus. This transport is responsible for losses due to the particles deposition on the walls, leading to a distortion on the concentration measurements and a change in the particle size distribution. To estimate and minimize measurement errors it is important to determine the optimal transport conditions when designing a duct; its diameter and material, the radius of curvature of the bends and the flow conditions must be defined in particular. This paper presents an experimental study in order to determine, for each deposition mechanism, the retained fraction, or the deposition velocity for different flow regimes. This study has pointed out that it exists a favourable flow regime for the particle transport through the sampling ducts (2 500 < Re < 5 000). It has been established, for any particle diameters, equations to predict the aerosol penetration in smooth-walled cylindrical metal ducts

  19. A Symptom Survey and Quality of Life Questionnaire for Nasolacrimal Duct Obstruction in Children

    Science.gov (United States)

    Holmes, Jonathan M.; Leske, David A.; Cole, Stephen R.; Chandler, Danielle L.; Repka, Michael X.; Silbert, David I.; Tien, David Robbins; Bradley, Elizabeth A.; Sala, Nicholas A.; Levin, Erika M.; Hoover, Darron L.; Klimek, Deborah L.; Mohney, Brian G.; Laby, Daniel M.; Lee, Katherine A.; Enzenauer, Robert W.; Bacal, Darron A.; Mills, Monte D.; Beck, Roy W.

    2008-01-01

    Purpose To develop and validate a new parental questionnaire addressing symptoms and health related quality of life (HRQL) in congenital nasolacrimal duct obstruction (NLDO). Design Cross-sectional study. Participants Children aged 6 to studies of NLDO PMID:16828516

  20. Low Cost/Low Noise Variable Pitch Ducted Fan, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ACI proposes a design for a Propulsor (Low Cost/Low Noise Variable Pitch Ducted Fan) that has wide application in all sectors of Aviation. Propulsor hardware of this...

  1. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  2. Quadcopter thrust optimization with ducted-propeller

    Directory of Open Access Journals (Sweden)

    Kuantama Endrowednes

    2017-01-01

    Full Text Available In relation to quadcopter body frame model, propeller can be categorized into propeller with ducted and without ducted. This study present differences between those two using CFD (Computational Fluid Dynamics method. Both categories utilize two blade-propeller with diameter of 406 (mm. Propeller rotation generates acceleration per time unit on the volume of air. Based on the behavior of generated air velocity, ducted propeller can be modeled into three versions. The generated thrust and performance on each model were calculated to determine the best model. The use of ducted propeller increases the total weight of quadcopter and also total thrust. The influence of this modeling were analyzed in detail with variation of angular velocity propeller from 1000 (rpm to 9000 (rpm. Besides the distance between propeller tip and ducted barrier, the size of ducted is also an important part in thrust optimization and total weight minimization of quadcopter.

  3. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M. [Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, University of Vigo, Campus Lagoas-Marcosende No. 9, 36310 Vigo (Spain)

    2011-01-15

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper. (author)

  4. Comparison of the Standard of Air Leakage in Current Metal Duct Systems in the World

    Science.gov (United States)

    Di, Yuhui; Wang, Jiqian; Feng, Lu; Li, Xingwu; Hu, Chunlin; Shi, Junshe; Xu, Qingsong; Qiao, Leilei

    2018-01-01

    Based on the requirements of air leakage of metal ducts in Chinese design standards, technical measures and construction standards, this paper compares the development history, the classification of air pressure levels and the air tightness levels of air leakage standards of current Chinese and international metal ducts, sums up the differences, finds shortage by investigating the design and construction status and access to information, and makes recommendations, hoping to help the majority of engineering and technical personnel.

  5. Thermal neutrons streaming in straight duct

    International Nuclear Information System (INIS)

    Jehouani, A.; Boulkheir, M.; Ichaoui, R.

    2000-01-01

    The neutron streaming in duct is due to two phenomena: a) direct propagation and b) reflection on duct wall. We have used the Monte Carlo method to evaluate the ratio of the reflected neutrons flux by the duct wall to the total flux at the exit of the duct for iron and aluminium. Ten neutrons energy groups are considered between 10 -5 eV and 10 eV. A Fortran program is developed to evaluate the neutron double differential albedo. It is shown that the two following approximations are largely justified: i) Three collisions in the duct wall are sufficient to attain the asymptotic limit of the multiscattered neutron double differential albedo ii) The points of entry and exit of the neutron in the duct wall may be considered the same for the multiscattered neutrons. For a punctual source at the mouth of the duct, we have determined the direct and the reflected part of the total thermal neutron flux at the exit of the duct for different lengths and different radius of the duct. For a punctual source, we have found that the major contribution to the total flux of neutrons at the exit is due to the neutron reflection by walls and the reflection contribution decreases when the neutron energy decreases. For a constant length of the duct, the reflected part decreases when the duct radius increases while for the disk shaped source we have found the opposite phenomena. The transmitted neutron flux distribution at the exit of the duct are determined for disk shaped source for different neutron energy and for different distance from the exit center. (author)

  6. Molecular Mechanisms of Bile Duct Development

    OpenAIRE

    Zong, Yiwei; Stanger, Ben Z.

    2010-01-01

    The mammalian biliary system, consisting of the intrahepatic and extrahepatic bile ducts, is responsible for transporting bile from the liver to the intestine. Bile duct dysfunction, as is seen in some congenital biliary diseases such as Alagille syndrome and biliary atresia, can lead to the accumulation of bile in the liver, preventing the excretion of detoxification products and ultimately leading to liver damage. Bile duct formation requires coordinated cell-cell interactions, resulting in...

  7. Designing and evaluating an electronic patient falls reporting system: perspectives for the implementation of health information technology in long-term residential care facilities.

    Science.gov (United States)

    Mei, Yi You; Marquard, Jenna; Jacelon, Cynthia; DeFeo, Audrey L

    2013-11-01

    Patient falls are the leading cause of unintentional injury and death among older adults. In 2000, falls resulted in over 10,300 elderly deaths, costing the United States approximately $179 million in incidence and medical costs. Furthermore, non-fatal injuries caused by falls cost the United States $19 billion annually. Health information technology (IT) applications, specifically electronic falls reporting systems, can aid quality improvement efforts to prevent patient falls. Yet, long-term residential care facilities (LTRCFs) often do not have the financial resources to implement health IT, and workers in these settings are often not ready to adopt such systems. Additionally, most health IT evaluations are conducted in large acute-care settings, so LTRCF administrators currently lack evidence to support the value of health IT. In this paper, we detail the development of a novel, easy-to-use system to facilitate electronic patient falls reporting within a LTRCF using off-the-shelf technology that can be inexpensively implemented in a wide variety of settings. We report the results of four complimentary system evaluation measures that take into consideration varied organizational stakeholders' perspectives: (1) System-level benefits and costs, (2) system usability, via scenario-based use cases, (3) a holistic assessment of users' physical, cognitive, and marcoergonomic (work system) challenges in using the system, and (4) user technology acceptance. We report the viability of collecting and analyzing data specific to each evaluation measure and detail the relative merits of each measure in judging whether the system is acceptable to each stakeholder. The electronic falls reporting system was successfully implemented, with 100% reporting at 3-months post-implementation. The system-level benefits and costs approach showed that the electronic system required no initial investment costs aside from personnel costs and significant benefits accrued from user time savings

  8. Intraoperative cholangiographic findings of intrahepatic duct stones

    International Nuclear Information System (INIS)

    Kim, Mi Young; Suh, Chang Hae; Choi, Hye Ran; Ahn, Byeong Yeob; Chung, Woun Kyun; Lee, Yong

    1989-01-01

    Operative cholangiography is considered essential during biliary operation in order to minimise the chance of negative exploration and to demonstrate the anatomy and pathology of intra and extrahepatic biliary tree. Although many authors have evaluated and accepted various techniques for operative cholangiography, the image of operative cholangiography is affected mainly by intrahepatic duct stones and anatomic characteristic of biliary tree. In case of intrahepatic duct stones accurate evaluation of the operative cholangiographic findings is important for a plan of further treatment including interventional procedures. We reviewed 45 operative cholangiograms of 30 patients with intrahepatic duct stones from January,1986 to September, 1988, and analysed operative cholangiographic findings with a special attention to the correlation between cholangiographic findings and the location of intrahepatic duct stones. The results were as follows: 1. Common bile duct stones were found in 72%, and generalized cholangitis was combined in 43% of patient with intrahepatic duct stones. 2. Incomplete ductal filling of contrast media was the most frequent findings of left intrahepatic duct stones in operative cholangiograms with four different cholangiogram catheters. 3. Nonfilling and partial filling were the most frequent findings; nonfilling was prevalent in right anterior and left medial ducts, and partial filling was prevalent in left medial and left lateral ducts

  9. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    OpenAIRE

    Darghouth, Naim Richard

    2013-01-01

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation co...

  10. Guidelines for Transferring Residential Courses into Web

    Science.gov (United States)

    Tüzün, Hakan; Çinar, Murat

    2016-01-01

    This study shared unique design experiences by examining the process of transferring residential courses to the Web, and proposed a design model for individuals who want to transfer their courses into this environment. The formative research method was used in the study, and two project teams' processes of putting courses, which were being taught…

  11. Techniques for cutting irradiated fuel ducts at FFTF/IEM cell

    International Nuclear Information System (INIS)

    Payzant, W.H.

    1990-09-01

    Two remotely controlled mill-type cutters have been used in the Fast Flux Test Facility Interim Examination and Maintenance Cell to assist in the disassembly of 18 fuel assemblies. These cutters slit the outer duct of the fuel assemblies, which allows the ducts to be removed and provides access to the encased fuel pins. The cutters were developed by Westinghouse Hanford Company and thoroughly tested by cutting prototypic ducts. During actual use, however, occasional loss of cutting depth control occurred. A discussion of the control problems and the operation and design techniques developed for their resolution is presented. 3 refs., 7 figs

  12. Laparoscopic common bile duct exploration.

    Science.gov (United States)

    Shuchleib, S; Chousleb, A; Mondragon, A; Torices, E; Licona, A; Cervantes, J

    1999-07-01

    Since the introduction of laparoscopic cholecystectomy, the management of common bile duct (CBD) stones has undergone significant change. Preoperative endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy is now routinely done in cases where the diagnosis of choledocholithiasis is suspected preoperatively, with clearance of the bile ducts before laparoscopic cholecystectomy. Intraoperative discovery of CBD stones by cholangiography represents a challenge to the surgeon, who must make a decision about when to perform laparoscopic CBD exploration, convert to open surgery, or send the patient for ERCP during the postoperative period. Because ERCP has a definite failure rate, laparoscopic CBD exploration can be a treatment option. Among 2500 laparoscopic cholecystectomies done by our group from January 1991 to June 1997, 50 patients (2%) underwent laparoscopic CBD exploration, 13 by the transcystic technique and 37 by choledocotomy, with a conversion rate of 8% and a hospital stay of 4.3 days. One patient died from complicated pancreatitis following ERCP and unsuccessful extraction of a CBD stone. We obtained our goal of a CBD free of stones in 92% of the cases. We conclude that laparoscopic CBD exploration is an effective method for treating choledocolithiasis that allows management of this pathology in one stage, although it requires advanced laparoscopic skills and adequate equipment.

  13. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, S. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  14. Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  15. Persistent Mullerian Duct Syndrome with Transverse Testicular ...

    African Journals Online (AJOL)

    The Mullerian duct regresses in male due to a glycoprotein secreted by the developing testes called. Mullerian inhibiting factor (MIF). Failure to regress may be due to lack of MIF or defective MIF receptor, resulting in various disorders of regression, and one such disorder is persistent Mullerian duct syndrome (PMDS).

  16. Prostatic Duct Adenocarcinoma with Endometrioid Features: Report ...

    African Journals Online (AJOL)

    mn

    4, 2009. 257. 257-258. Case Report. Prostatic Duct Adenocarcinoma with Endometrioid. Features: Report of a Rare Case and Brief Review of the Literature ... 3. adenocarcinoma of the prostate: A distinctive tumor of probable prostatic duct origin. Cancer. 1976;. May;37(5):2255-62. Cohen RJ, Wheeler TM, Bonkhoff H, ...

  17. Calcium influx pathways in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Hug, M J; Pahl, C; Novak, I

    1996-01-01

    A number of agonists increase intracellular Ca2+ activity, [Ca2+]i, in pancreatic ducts, but the influx/efflux pathways and intracellular Ca2+ stores in this epithelium are unknown. The aim of the present study was to characterise the Ca2+ influx pathways, especially their pH sensitivity, in native...... pathways in pancreatic ducts cells....

  18. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  19. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  20. Cholangiographic evaluation of bile duct carcinoma

    International Nuclear Information System (INIS)

    Nichols, D.A.; MacCarty, R.L.; Gaffey, T.A.

    1983-01-01

    Cholangiograms and clinical histories of 82 patients with biopsy-proved bile duct carcinoma were reviewed. The carcinomas were classified according to morphologic findings and clinical outcome. Ulcerative colitis and antecedent inflammatory disease of the biliary tree, particularly primary sclerosing cholangitis, seem to predispose to the development of bile duct carcinoma. Focal stenotic lesions were the most common morphologic type (62/82). Polypoid carcinomas and diffuse sclerosing carcinomas were less common and of about equal frequency. Prognosis was best for patients with polypoid carcinomas and worst for those with diffuse sclerosing carcinomas. In 69 cases (84%), the tumors involved the intrahepatic or proximal extrahepatic ducts, makin curative resection difficult or impossible. Patients with carcinomas limited to the more distal extrahepatic bile ducts had a longer average survival and a higher probability of surgical cure. Proper management of patients with bile duct carcinoma requires a complete and accurate cholangiographic evaluation of the morphology, location, and extent of the disease

  1. Salivary Duct Cyst: Histo-pathologic Correlation

    Directory of Open Access Journals (Sweden)

    Divya Vinayachandran

    2013-01-01

    Full Text Available Non-neoplastic cysts of the salivary glands are uncommon and represent 2-5% of all salivary gland lesions. They are mainly mucoceles or salivary duct cysts. Unlike a mucocele, which is surrounded by granulation tissue, the salivary duct cyst is lined by epithelium. Salivary duct cysts are more common in the oral minor salivary glands and rarely occur in the major salivary glands, show a marked predilection for the superficial lobe of the parotid, and represent 10% of all salivary gland cysts. Neoplastic differentiation of the lining of the salivary duct cyst has been reported. We report a case of a salivary duct cyst of the left parotid gland, with a review of radiographic and histopathologic features.

  2. The Impact of Bile Duct Cultures on Surgical Site Infections in Pancreatic Surgery.

    Science.gov (United States)

    Herzog, Torsten; Belyaev, Orlin; Akkuzu, Rehsan; Hölling, Janine; Uhl, Waldemar; Chromik, Ansgar M

    2015-08-01

    In pancreatic surgery pre-operative biliary drainage (PBD) is associated with bacteribilia, which increases the risk for surgical site infections (SSIs). This study is a retrospective observational cohort design that compared micro-organisms of intra-operative bile duct cultures with micro-organisms of SSIs after pancreaticoduodenectomy. From January 2004 until December 2010, 887 patients underwent pancreaticoduodenectomy or hepaticojejunostomy for benign and malignant peri-ampullary lesions. Surgical site infections occurred in 10% (87/887). Cultures of SSIs with corresponding intra-operative bile duct cultures were available for 59 patients. Sixty-four percent (38/59) had undergone PBD. Pre-operative biliary drainage was associated with positive intra-operative bile duct cultures in 95% (36/38), versus 48% (10/21; p≤0.001). The correlation of SSIs with intra-operative bile duct cultures was 59% (35/59). There was a significant association between the micro-organisms cultured from SSIs and the corresponding bile duct cultures for Enterococcus spp., Escherichia coli, Klebsiella pneumoniae, methicillin-resistant Staphylococcus aureus (MRSA), Enterobacteriaceae with extended spectrum ß-lactamase (ESBL), and Candida spp. After pancreaticoduodenectomy, SSIs are often caused by the same micro-organisms that are present on intra-operative bile duct cultures, especially after PBD. Therefore, intra-operative bile duct cultures should be performed routinely to adjust the antibiotic prophylaxis according to the local hospital surveillance data.

  3. Invisible Elderly in Danish and Swedish Residential Care Home Architecture

    DEFF Research Database (Denmark)

    E Andersson, Jonas; Grangaard, Sidse

    2015-01-01

    This study of two architectural competitions suggests that the fit between architectural design and older users, who depend on regular caregiving due to cognitive or functional disabilities, requires a particular consideration when designing new residential care homes.......This study of two architectural competitions suggests that the fit between architectural design and older users, who depend on regular caregiving due to cognitive or functional disabilities, requires a particular consideration when designing new residential care homes....

  4. Euler/Navier-Stokes Solvers Applied to Ducted Fan Configurations

    Science.gov (United States)

    Keith, Theo G., Jr.; Srivastava, Rakesh

    1997-01-01

    Due to noise considerations, ultra high bypass ducted fans have become a more viable design. These ducted fans typically consist of a rotor stage containing a wide chord fan and a stator stage. One of the concerns for this design is the classical flutter that keeps occurring in various unducted fan blade designs. These flutter are catastrophic and are to be avoided in the flight envelope of the engine. Some numerical investigations by Williams, Cho and Dalton, have suggested that a duct around a propeller makes it more unstable. This needs to be further investigated. In order to design an engine to safely perform a set of desired tasks, accurate information of the stresses on the blade during the entire cycle of blade motion is required. This requirement in turn demands that accurate knowledge of steady and unsteady blade loading be available. Aerodynamic solvers based on unsteady three-dimensional analysis will provide accurate and fast solutions and are best suited for aeroelastic analysis. The Euler solvers capture significant physics of the flowfield and are reasonably fast. An aerodynamic solver Ref. based on Euler equations had been developed under a separate grant from NASA Lewis in the past. Under the current grant, this solver has been modified to calculate the aeroelastic characteristics of unducted and ducted rotors. Even though, the aeroelastic solver based on three-dimensional Euler equations is computationally efficient, it is still very expensive to investigate the effects of multiple stages on the aeroelastic characteristics. In order to investigate the effects of multiple stages, a two-dimensional multi stage aeroelastic solver was also developed under this task, in collaboration with Dr. T. S. R. Reddy of the University of Toledo. Both of these solvers were applied to several test cases and validated against experimental data, where available.

  5. Residentialization of Public Spaces: Bratislava Example

    Science.gov (United States)

    Bacová, Andrea; Puškár, Branislav; Vráblová, Edita

    2017-10-01

    The housing estates in Bratislava saturated the housing needs of a large number of inhabitants who come after World War II to the city. Design of public spaces often did not have priority in the process of designing. The solutions for mentioned exterior spaces had been planned after blocks of flat realization, but many of them are not realized to this day. The article analyzes the example of the unrealized public spaces in existing housing estates Devinska Nova Ves and Petržalka (city districts of Bratislava) and offer practical solutions in relation to residencialization method. Residencialization of missing public places is an effective method of adding identities to settlements. It improves the quality of residential environment and public spaces. The main aim is to create better conditions for social activities in public areas, which are missing on the present. The research will be focused on the examination of the urban, cultural and construction potential of the existing residential enviroment in Bratislava. The main aim of residentialization is not only to enhance the quality of spatial and building structures in the selected residential area and maintain long-term sustainability in the pertinent programme area, but mainly to improve the quality of living for the residents. The outputs of the project are proposals and practical procedures developed with regard to planning documents for local municipal authorities and regional organizations. The solutions will have a positive impact on the enhancement of the quality of public spaces, attractive social activities and of a conceptual link - residentialization.

  6. Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Magee, A.; Zoeller, W.

    2013-02-01

    The Consortium for Advanced Residential Buildings (CARB) monitored three houses in Jacksonville, FL, to investigate the effectiveness of encapsulated and encapsulated/buried ducts in reducing thermal losses and gains from ductwork in unconditioned attics. Burying ductwork beneath loose-fill insulation has been identified as an effective method of reducing thermal losses and gains from ductwork in dry climates, but it is not applicable in humid climates where condensation may occur on the outside of the duct jacket. By encapsulating the ductwork in closed cell polyurethane foam (ccSPF) before burial beneath loose-fill mineral fiber insulation, the condensation potential may be reduced while increasing the R-value of the ductwork.

  7. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp; Ueno, Yutaka, E-mail: uenoyut@hirakata.kmu.ac.jp; Komemushi, Atsushi, E-mail: komemush@takii.kmu.ac.jp; Tanigawa, Noboru, E-mail: tanigano@hirakata.kmu.ac.jp [Kansai Medical University, Department of Radiology (Japan)

    2017-01-15

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  8. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    International Nuclear Information System (INIS)

    Kariya, Shuji; Nakatani, Miyuki; Yoshida, Rie; Ueno, Yutaka; Komemushi, Atsushi; Tanigawa, Noboru

    2017-01-01

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  9. Bile Duct Adenoma with Oncocytic Features

    Directory of Open Access Journals (Sweden)

    E. J. Johannesen

    2014-01-01

    Full Text Available Bile duct adenomas are benign bile duct proliferations usually encountered as an incidental finding. Oncocytic bile duct neoplasms are rare and the majority are malignant. A 61-year-old male with a diagnosis of colorectal adenocarcinoma was undergoing surgery when a small white nodule was discovered on the surface of the right lobe of his liver. This lesion was composed of cytologically bland cells arranged in tightly packed glands. These cells were immunopositive for cytokeratin 7, negative for Hep Par 1, contained mucin, and had a Ki67 proliferation index of 8%. The morphology, immunophenotype, presence of mucin, and normal appearing bile ducts, as well as the increased Ki67 proliferation rate, were consistent with a bile duct adenoma with oxyphilic (oncocytic change. Oncocytic tumors in the liver are rare; the first described in 1992. Only two bile duct adenomas with oncocytic change have been reported and neither of them had reported mucin production or the presence of normal appearing bile ducts within the lesion.

  10. Building America Case Study: Compact Buried Ducts in a Hot-Humid Climate House, Lady's Island, South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    2016-02-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences, 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs, and 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

  11. Evaluation of prototype electrofibrous filters for nuclear ventilation ducts

    International Nuclear Information System (INIS)

    Bergman, W.; Kuhl, W.D.; Biermann, A.H.; Johnson, J.S.; Lum, B.Y.

    1983-01-01

    Two prototype electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. These prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposable prefilter is effectively prolonging the HEPA filter life

  12. Evaluation of prototype electrofibrous filters for nuclear-ventilation ducts

    International Nuclear Information System (INIS)

    Bergman, W.; Kuhl, W.D.; Biermann, A.H.; Johnson, J.S.; Lum, B.Y.

    1982-01-01

    Two prototypes electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. These prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposable prefilter is effectively prolonging the HEPA filter life

  13. Development of an Ultralight with a Ducted Fan

    Directory of Open Access Journals (Sweden)

    Jiří Brabec

    2012-01-01

    Full Text Available This paper introduces the UL-39 project, an ultralight aircraft with a ducted fan, and some of the problems that have arisen in the course of its development. Several problems with the design of a non-traditional aircraft of this kind are mentioned, e.g. the design of the airframe, and the design of the propulsion unit. The paper describes the specific procedure for determining the basic thrust characteristics of this unusual aircraft concept, and also the experimental determination of these characteristics. Further options for applying the experience gained during the work, and the futurefocus of work on these issues, are outlined at the end of the paper.

  14. MICRO-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Gerstmann

    2009-01-31

    This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

  15. [Salivary gland drainage into the thyroglossal duct].

    Science.gov (United States)

    Siem, G; Natvig, K; Kolbenstvedt, A; Lømo, J

    2001-01-20

    Failure in regression of the thyroglossal duct is one of the most common reasons for midline swellings in the neck. Several authors have described recurrent thyroglossal duct remnants with persisting draining sinuses. However, few have described accessory salivary glands that drain into the thyroglossal duct. In this article we report two such cases with midline salivary glands in the floor of the mouth. These two patients were subsequently successfully treated with radical tissue resection in the area between the hyoid bone and foramen cecum. Preoperative fistulography or sinography was useful to demonstrate the ductal ramification of the salivary glands, and use of methylene blue during surgery proved of significant value for the result.

  16. Citizens Utilities Company's successful residential new construction market transformation program

    Energy Technology Data Exchange (ETDEWEB)

    Caulfield, T.O.; Shepherd, M.A.

    1998-07-01

    Citizens Utilities Company, Arizona Electric Division (CUC/AED) fielded a Residential New Construction Program (RNC) in the forth quarter of 1994 that had been designed from conception as a market transformation program. The CUC RNC Program encouraged builders to adopt energy efficient building practices for new homes by supplying builders estimates of energy savings, supplying inspections services to assist builders in applying energy efficient building practices while verifying compliance, and posting and promoting the home as energy efficient during the sales period. Measures generally required to qualify for the program were R-38 ceiling insulation, R-21 wall insulation, polysealing of all infiltration gaps during construction, well sealed air-conditioning ducts, and an air conditioner Seasonal Energy Efficiency Rating (SEER) of 11.0 or greater. In less than two years the program achieved over 17% market penetration without offering rebates to builders. This paper reviews the design of the program, including a discussion of the features felt to be primarily responsible for its success. It reviews the levels of penetration achieved, free-ridership, spillover, and market barriers encountered. Finally it proposes improvements to the program designed to carry it the next step toward a self-sustaining market transformation program.

  17. Traumatic resin ducts as indicators of bark beetle outbreaks

    Science.gov (United States)

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  18. Primary hepatocellular carcinoma in extrahepatic bile duct

    International Nuclear Information System (INIS)

    Jeong, Seok Tae; Ham, Soo Youn; Park, Cheol Min; Kim, Jung Hyuk; Cha, In Ho; Chung, Kyoo Byung; Suh, Woon Hyuck; Lee, Chang Hong

    1991-01-01

    Obstructive jaundice due to hepatocellular carcinoma in an extrahepatic bile duct, without a mass lesion in the liver parenchyma, is extremely rare. We experienced two cases of primary hepatocellular carcinoma arising from an extrahepatic bile duct: one in a 53-year-old man whose α -fetoprotein value was 800 ng/ml, and another in a 39-year-old woman, in whom the mass lesion was found to be attached to an extrahepatic bile duct. These tumors had a well-marginated sausage-like shape on CT and US, and the contrast media passed freely along their margins on both PTC and ERCP. Recurrences of these tumors were observed in the extrahepatic bile duct 6 and 2 months after surgery, respectively

  19. Unusually large sialolith of Wharton's duct

    Science.gov (United States)

    Iqbal, Ali; Gupta, Anup K.; Natu, Subodh S.; Gupta, Atul K.

    2012-01-01

    The formation of calcific concretions in the salivary duct or glands is a common disorder, especially in the submandibular glands. Most of the salivary calculi are small in size, in contrast to those that reach several centimeters, which are reported as megaliths or giant calculi in the literature. They may occur in any of the salivary gland ducts but are most common in Wharton's duct and the submandibular gland. This report presents clinical and radiographical sign of an unusually large sialolith. There was painless swelling on the floor of the edentulous mouth and patient was unaware of it. Radiographical examination revealed large irregular radio-opaque mass superimposed on right canine and premolar areas. This case report describes a patient presenting with an unusually large submandibular gland duct sialolith, the subsequent patient management, the aetiology, diagnosis and its treatment. PMID:23483770

  20. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    International Nuclear Information System (INIS)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A.; Rambhatla, Siri J.; Sreedharan, Ram R.

    2015-01-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  1. Reference values of MRI measurements of the common bile duct and pancreatic duct in children

    Energy Technology Data Exchange (ETDEWEB)

    Gwal, Kriti; Bedoya, Maria A.; Patel, Neal; Darge, Kassa; Anupindi, Sudha A. [University of Pennsylvania Perelman School of Medicine, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Rambhatla, Siri J. [Beth Israel Medical Center, Department of Pediatrics, Newark, NJ (United States); Sreedharan, Ram R. [University of Pennsylvania, Departments of Gastroenterology, Hepatology and Nutrition, The Children' s Hospital of Philadelphia, Perelman School of Medicine, Philadelphia, PA (United States)

    2015-08-15

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial

  2. Cleanliness of ventilation ducts, indoor space and AHU

    OpenAIRE

    Rubina, Aleš; Rubinová, Olga; Blasinski, Petr

    2015-01-01

    Paper deals with analysis of cleanliness air conditioning duct for various stages of construction. There were taken samples and these were analyzed for different type of storage duct on construction. They are compared differences between the "right" stored duct and unprotected duct including the actual interior space and air handling units serving. In the conclusion of this article is summarized the impact of carryover dirt from the duct and an air handling unit to the ventilation s...

  3. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  4. Condition assessment and strengthening of residential units

    Directory of Open Access Journals (Sweden)

    Tatheer Zahra

    2014-01-01

    Full Text Available About 40, ground plus one (G+1 residential units were designed using a hybrid structural framing system (RC frame and load bearing walls. A few months after the completion of the ground floor of the residential units, cracks appeared at several locations in the structure. Field and Laboratory testing was conducted to ascertain the in situ strength of concrete and steel reinforcement. The results of the experimental work were used in the analytical ETABS model for the structural stability calculations. The results indicated that residential units were marginally safe in the existing condition (completed ground floor, but the anticipated construction of the floor above the ground floor (G+1 could not be carried out as the strength of the structural system was inadequate. To increase the safety of existing ground floor and to provide the option of the construction of one floor above, rehabilitation and strengthening design was performed. The proposed strengthening design made use of welded wire fabric (WWF and carbon fibre reinforced polymer (CFRP laminates/sheets for the strengthening of walls, columns and slabs. The residential units will be strengthened in the near future.

  5. Environmental impacts during the operational phase of residential buildings

    NARCIS (Netherlands)

    Blom, I.S.

    2010-01-01

    To date, the focus in the field of sustainable building has been on new building design. However, existing residential buildings inflict great environmental burden through three causes: continuous energy consumption, regular building maintenance and replacements. This publication analyses and

  6. Thermal performance test of hot gas ducts of helium engineering demonstration loop (HENDEL)

    International Nuclear Information System (INIS)

    Hishida, Makoto; Kunitomi, Kazuhiko; Ioka, Ikuo; Umenishi, Koji; Kondo, Yasuo; Tanaka, Toshiyuki; Shimomura, Hiroaki

    1984-01-01

    A hot gas duct provided with internal thermal insulation is supposed to be used for an experimental very high-temperature gas-cooled reactor (VHTR) which has been developed by the Japan Atomic Energy Research Institute (JAERI). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of hot gas duct have been conducted. The present test was to investigate the thermal performance of the hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL) of JAERI. Uniform temperature and heat flux distributions at the surface of the duct were observed, the experimental correlation being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of VHTR hot gas duct was evaluated, and no hot spot was detected. These results would be very valuable for the design and development of VHTR. (author)

  7. Hybrid model predictive control of a residential HVAC system with on-site thermal energy generation and storage

    International Nuclear Information System (INIS)

    Fiorentini, Massimo; Wall, Josh; Ma, Zhenjun; Braslavsky, Julio H.; Cooper, Paul

    2017-01-01

    Highlights: • A comprehensive approach to managing thermal energy in residential buildings. • Solar-assisted HVAC system with on-site energy generation and storage. • Mixed logic-dynamical building model identified using experimental data. • Design and implementation of a logic-dynamical model predictive control strategy. • MPC applied to the Net-Zero Energy house winner of the Solar Decathlon China 2013. - Abstract: This paper describes the development, implementation and experimental investigation of a Hybrid Model Predictive Control (HMPC) strategy to control solar-assisted heating, ventilation and air-conditioning (HVAC) systems with on-site thermal energy generation and storage. A comprehensive approach to the thermal energy management of a residential building is presented to optimise the scheduling of the available thermal energy resources to meet a comfort objective. The system has a hybrid nature with both continuous variables and discrete, logic-driven operating modes. The proposed control strategy is organized in two hierarchical levels. At the high-level, an HMPC controller with a 24-h prediction horizon and a 1-h control step is used to select the operating mode of the HVAC system. At the low-level, each operating mode is optimised using a 1-h rolling prediction horizon with a 5-min control step. The proposed control strategy has been practically implemented on the Building Management and Control System (BMCS) of a Net Zero-Energy Solar Decathlon house. This house features a sophisticated HVAC system comprising of an air-based photovoltaic thermal (PVT) collector and a phase change material (PCM) thermal storage integrated with the air-handling unit (AHU) of a ducted reverse-cycle heat pump system. The simulation and experimental results demonstrated the high performance achievable using an HMPC approach to optimising complex multimode HVAC systems in residential buildings, illustrating efficient selection of the appropriate operating modes

  8. Enucleation or exenteration in two dogs with previous parotid duct transposition: parotid duct ligation versus reverse parotid duct transposition.

    Science.gov (United States)

    Young, Whitney M; Betbeze, Caroline M; Fisher, Stephen C; Boulay, James P

    2017-08-27

    Two dogs with previous parotid duct transpositions presented with unrelated ocular disease. In both cases, ophthalmic examination revealed the need for enucleation or exenteration. In case 1, systemic coccidioidomycosis was diagnosed with panuveitis and secondary glaucoma of the left eye. In this case, the parotid duct was ligated at the time of enucleation to stop salivary secretions. This dog encountered morbidity in the form of a sialocele that did not resolve for 11 months. In case 2, ultrasound and computed tomography revealed a discrete mass within the left medial orbit that was suspected to arise from the nictitating membrane. A combination of exenteration and parotid duct transposition reversal was performed to avoid morbidity associated with ligation of the parotid duct. The dog encountered no complications from this novel procedure. This case report represents the first report of re-routing a transposed parotid duct from the ventral conjunctival sac back to the mouth at the time of enucleation or exenteration in the dog. © 2017 American College of Veterinary Ophthalmologists.

  9. Ultrasound appearance of chronic mammary duct ectasia

    Energy Technology Data Exchange (ETDEWEB)

    Duchesne, N. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)]. E-mail: nathalie_duchesne_22@yahoo.ca; Skolnik, S. [Univ. of Toronto, Dept. of Family Medicine, Toronto, Ontario (Canada); Bilmer, S. [Ottawa Hospital, Dept. of Radiology, Ottawa, Ontario (Canada)

    2005-12-15

    Mammary duct ectasia (MDE), also called periductal mastitis, mammary dysplasia, or plasma cell mastitis, is a benign condition of the mammary gland first described by Haagensen in 1951. The etiology of MDE is unknown and its pathogenesis still controversial; the periductal inflammation could be either the cause or the result of dilated damaged ducts. The process is usually bilateral and asymptomatic, with only a small percentage of patients presenting with symptoms that may include long course of tumour formation, usually subareolar breast lumps, nipple discharge, nipple retraction, mastalgia, and mammary abscess or fistulas. Mammographic presentation of MDE is well known; its features include periductal calcification, benign intraductal calcification, and retroareolar duct dilatation. The periductal calcification results from dystrophic calcification and forms calcified rings or very dense, oval, elongated calcifications, each with a central lucency representing the dilated duct. Intraductal calcifications of duct ectasia represent inspissated intraductal material and are typically of uniform high density, often needle-like, and occasionally branching. Occasionally, there are no mammographic findings, and the diagnosis must rely on sonographic features. Appearance of MDE on ultrasonography (US) depends on the stage of the disease and the contents of the dilated ducts. The acute presentation has been demonstrated in the literature more often than has its chronic counterpart. In the former, duct content can vary from anechoic to isoechoic with surrounding fatty tissue. In chronic MDE, episodes of inflammation are longer. This tends to result in secretions that have a more solid, cheesy texture, partly due to cholesterol crystals, foam cells, and inflammatory cells. For both types of MDE, the appearance can mimic high-grade ductal carcinoma in situ (DCIS) on US. In this essay, 2 chronic MDE cases are presented and their US appearance discussed. Our goal is to explore

  10. The "flying" bile duct: avulsion of the common bile duct in a plane crash survivor.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Blunt trauma is an unusual cause of extrahepatic bile duct injury. This is a case of a 51-year-old gentleman who sustained a significant seatbelt injury in a plane crash. Laparotomy, performed due to persistent abdominal pain, revealed that the common bile duct (CBD) was completely avulsed from the duodenum. Following insertion of drains and transfer to a hepatobiliary centre, the devascularised CBD was excised and replaced with a roux-en-y hepaticojejunostomy. Necrotic tissue was debrided from the pancreatic head. A persistent bile leak developed from the sub-hepatic drain. Repeat laparotomy revealed a bile leak from small ducts on the liver surface. Ligation of the ducts and bioglue sealing of the area were successfully performed. Subsequent to this a pancreatic fistula developed from the main pancreatic duct, which has since resolved. This unusual case illustrates the need for prompt recognition and early repair to optimise outcomes in traumatic CBD injury.

  11. Development of an Ultrasonic Airflow Measurement Device for Ducted Air

    Science.gov (United States)

    Raine, Andrew B.; Aslam, Nauman; Underwood, Christopher P.; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  12. Development of an Ultrasonic Airflow Measurement Device for Ducted Air

    Directory of Open Access Journals (Sweden)

    Andrew B. Raine

    2015-05-01

    Full Text Available In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers.

  13. Guidelines for residential commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-31

    Currently, houses do not perform optimally or even as many codes and forecasts predict, largely because they are field assembled and there is no consistent process to identify problems or to correct them. Residential commissioning is a solution to this problem. This guide is the culmination of a 30-month project that began in September 1999. The ultimate objective of the project is to increase the number of houses that undergo commissioning, which will improve the quality, comfort, and safety of homes for California citizens. The project goal is to lay the groundwork for a residential commissioning industry in California focused on end-use energy and non-energy issues. As such, we intend this guide to be a beginning and not an end. Our intent is that the guide will lead to the programmatic integration of commissioning with other building industry processes, which in turn will provide more value to a single site visit for people such as home energy auditors and raters, home inspectors, and building performance contractors. Project work to support the development of this guide includes: a literature review and annotated bibliography, which facilitates access to 469 documents related to residential commissioning published over the past 20 years (Wray et al. 2000), an analysis of the potential benefits one can realistically expect from commissioning new and existing California houses (Matson et al. 2002), and an assessment of 107 diagnostic tools for evaluating residential commissioning metrics (Wray et al. 2002). In this guide, we describe the issues that non-experts should consider in developing a commissioning program to achieve the benefits we have identified. We do this by providing specific recommendations about: how to structure the commissioning process, which diagnostics to use, and how to use them to commission new and existing houses. Using examples, we also demonstrate the potential benefits of applying the recommended whole-house commissioning approach to

  14. Detailed residential electric determination

    Energy Technology Data Exchange (ETDEWEB)

    1984-06-01

    Data on residential loads has been collected from four residences in real time. The data, measured at 5-second intervals for 53 days of continuous operation, were statistically characterized. An algorithm was developed and incorporated into the modeling code SOLCEL. Performance simulations with SOLCEL using these data as well as previous data collected over longer time intervals indicate that no significant errors in system value are introduced through the use of long-term average data.

  15. Ice Protection of Turbojet Engines by Inertia Separation of Water II : Single-offset-duct System

    Science.gov (United States)

    Von Glahn, Uwe

    1948-01-01

    Investigation of a single-offset-duct system designed to prevent entrance of water into a turbojet engine was conducted on a half-scale nacelle model. An investigation was made to determine ram-pressure recovery and radial velocity profiles at the compressor section and icing characteristics of such a duct system. At a design inlet velocity of 0.77, the maximum ram-pressure recovery attained with effective water-separating inlet was 77 percent, which is considerably less than attainable with a direct-ram inlet. Continuous heating of the accessory-housing surface would be required for inlets that have a small ice storage space.

  16. Percutaneous electrohydraulic lithotripsy of bile duct stones

    International Nuclear Information System (INIS)

    Juliani, E.; Righi, D.; Cesarani, F.; Regge, D.; Gandini, G.

    1988-01-01

    The results are reported of percutaneous transhepatic tratment with an electrohydraulic stone disintegrator in 4 cases of bile duct lithiasis. An electri discharge, generated by a bipolar electrode, gives origin to high-amplitude and low-frequency shoc waves in the fluid medium-which cause the stone to fragment. Complete resolution of lithiasis was obtained in 2 patients with intrahepatic calculosis. In the other 2 cases of massive lithiasis of intra and extrahepatic bile ducts the treatment, however incomplete, proved to be useful, as the biliary flux was reabilitated and clinical symptoms disappeared. No relevant immediate side-effects were observed, except for well-tolerated pain during the discharges, and transitory hemobilia which solved spontaneously. No complications were observed in this series of patients. Electrohydraulic lithotripsy proves thus to be useful for supporting standard interventional radiology techniques in very complex cases of intra and extrahepatic bile duct stones

  17. Friction coefficient measurements of silencers on specialized duct tract

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2016-01-01

    Full Text Available This article describes test methods on air duct track in Laboratory of Environmental Engineering. It focuses on measurement of silencer parameter like is pressure loss coeffcient. Firstly, the paper describe the measurement apparatus with description of calculation method by standard ISO 7235 and energy equation. Then the paper presents three ways how to accomplish measurement because such way is not covered by procedure in standard. Then follows the evaluation of results of measurements on three types of silencer designed for HVAC applications. The article is concluded with discussion over measured data with outline for further research.

  18. Focus on Humanistic Values in Rural Livable Residential System

    Directory of Open Access Journals (Sweden)

    Sun Xiuli

    2015-01-01

    Full Text Available We consider the development of farmers as a goal of residential system using value rationality instead of farmer’s requirements which can be satisfied. Based upon the position and function of humanistic values in residential system, a rural housing system is built as a subjectivity and objectivity unity consisting of artifacts system, behavior system and concept system. Moreover, we introduce three coupling design strategies to rural livable residential system aiming to guide the current reconstruction of shabby buildings in rural areas.

  19. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  20. Xylometazoline hydrochloride nasal spray combined with laser artificial nasolacrimal duct implantation for nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Xiao-Zhao Yang

    2017-02-01

    Full Text Available AIM: To study the role of xylometazoline hydrochloride nasal spray in combination therapy of nasolacrimal duct obstruction and to investigate the effect of nasal inflammation on nasolacrimal duct obstruction. METHODS: Totally 279 patients with nasolacrimal duct obstruction were collected, who received lacrimal passage irrigation, CT angiography for lacrimal passage and nasal endoscope before treated by lacrimal laser forming and artificial nasolacrimal duct implantation combined with xylometazoline hydrochloride nasal spray. In group A, 137 patients were treated with antibiotic eye drop and non-steroidal anti-inflammatory drugs after operations. In group B, 142 patients were treated with xylometazoline hydrochloride nasal spray besides the same treatment for group A. RESULTS:In the 279 patients 217(77.8%, in which 105 cases(76.6%were in group A and 112 cases(78.9%were in group B, were suffered with nasal inflammation, including nasal mucosal hyperemia, inferior turbinate hypertrophy, middle turbinate hypertrophy. At 3mo after the ducts were drawn, efficacy of group B was 95.8%, which was significant better than that of group A(86.1%, PCONCLUSION: Nasal inflammation was an important factor in the incidence of nasolacrimal duct obstruction, which shoud pay more attention in the process of diagnosis and treatment. Combination therapy could improve the cure rate of nasolacrimal duct obstruction.

  1. Percutaneous treatment of benign bile duct strictures

    Energy Technology Data Exchange (ETDEWEB)

    Koecher, Martin [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)]. E-mail: martin.kocher@seznam.cz; Cerna, Marie [Department of Radiology, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Havlik, Roman [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Kral, Vladimir [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Gryga, Adolf [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic); Duda, Miloslav [Department of Surgery, University Hospital, I.P.Pavlova 6, 775 20 Olomouc (Czech Republic)

    2007-05-15

    Purpose: To evaluate long-term results of treatment of benign bile duct strictures. Materials and methods: From February 1994 to November 2005, 21 patients (9 men, 12 women) with median age of 50.6 years (range 27-77 years) were indicated to percutaneous treatment of benign bile duct stricture. Stricture of hepatic ducts junction resulting from thermic injury during laparoscopic cholecystectomy was indication for treatment in one patient, stricture of hepaticojejunostomy was indication for treatment in all other patients. Clinical symptoms (obstructive jaundice, anicteric cholestasis, cholangitis or biliary cirrhosis) have appeared from 3 months to 12 years after surgery. Results: Initial internal/external biliary drainage was successful in 20 patients out of 21. These 20 patients after successful initial drainage were treated by balloon dilatation and long-term internal/external drainage. Sixteen patients were symptoms free during the follow-up. The relapse of clinical symptoms has appeared in four patients 9, 12, 14 and 24 months after treatment. One year primary clinical success rate of treatment for benign bile duct stricture was 94%. Additional two patients are symptoms free after redilatation (15 and 45 months). One patient is still in treatment, one patient died during secondary treatment period without interrelation with biliary intervention. The secondary clinical success rate is 100%. Conclusion: Benign bile duct strictures of hepatic ducts junction or biliary-enteric anastomosis are difficult to treat surgically and endoscopically inaccessible. Percutaneous treatment by balloon dilatation and long-term internal/external drainage is feasible in the majority of these patients. It is minimally invasive, safe and effective.

  2. Percutaneous treatment of benign bile duct strictures

    International Nuclear Information System (INIS)

    Koecher, Martin; Cerna, Marie; Havlik, Roman; Kral, Vladimir; Gryga, Adolf; Duda, Miloslav

    2007-01-01

    Purpose: To evaluate long-term results of treatment of benign bile duct strictures. Materials and methods: From February 1994 to November 2005, 21 patients (9 men, 12 women) with median age of 50.6 years (range 27-77 years) were indicated to percutaneous treatment of benign bile duct stricture. Stricture of hepatic ducts junction resulting from thermic injury during laparoscopic cholecystectomy was indication for treatment in one patient, stricture of hepaticojejunostomy was indication for treatment in all other patients. Clinical symptoms (obstructive jaundice, anicteric cholestasis, cholangitis or biliary cirrhosis) have appeared from 3 months to 12 years after surgery. Results: Initial internal/external biliary drainage was successful in 20 patients out of 21. These 20 patients after successful initial drainage were treated by balloon dilatation and long-term internal/external drainage. Sixteen patients were symptoms free during the follow-up. The relapse of clinical symptoms has appeared in four patients 9, 12, 14 and 24 months after treatment. One year primary clinical success rate of treatment for benign bile duct stricture was 94%. Additional two patients are symptoms free after redilatation (15 and 45 months). One patient is still in treatment, one patient died during secondary treatment period without interrelation with biliary intervention. The secondary clinical success rate is 100%. Conclusion: Benign bile duct strictures of hepatic ducts junction or biliary-enteric anastomosis are difficult to treat surgically and endoscopically inaccessible. Percutaneous treatment by balloon dilatation and long-term internal/external drainage is feasible in the majority of these patients. It is minimally invasive, safe and effective

  3. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  4. Vibroacoustic Analysis of a Refrigerator Freezer Cabinet Coupled with an Air Duct

    Directory of Open Access Journals (Sweden)

    Onur Çelikkan

    2017-01-01

    Full Text Available In this study, the vibration and acoustic interactions between the structure and the cavity inside the freezer cabinet were investigated. Thus, a set of numerical and experimental analyses were performed. In the numerical analysis, the acoustic characteristics of the freezer cavity were solved, and the mixed finite element method was then implemented to analyse the coupled behaviour of the cavity with the air duct using the Acoustic Fluid-Structure Interaction (AFSI technique. In the experimental analyses, an acoustic modal analysis of the freezer cavity and a structural modal analysis of the air duct were performed for the validation process. A good agreement was obtained among the results. Thus, the accuracy of the numerical model was confirmed. The validated models were used for optimizing the design. To solve the noise generation mechanism inside the freezer cabinet, the noise primarily generated by the freezer fan unit was measured under normal working conditions of the refrigerator, and the resonance frequencies were obtained. This information was compared with the normal modes of the air duct, and the overlapping frequencies were identified. To reduce the interaction between the source and the structure, a few design modifications were applied to the air duct. Thus, the structural-borne noise radiating from the air duct into the freezer cavity was reduced.

  5. 'Nothing works' in secure residential youth care?

    NARCIS (Netherlands)

    Souverein, F.A.; van der Helm, G.H.P.; Stams, G.J.J.M.

    2013-01-01

    A debate about the effectiveness of secure residential youth care is currently going on. While some continue to support secure residential youth care, others conclude that ‘nothing works’ in secure residential youth care, and argue that non-residential treatment is superior to secure residential

  6. Salivary duct carcinoma of the palate

    Directory of Open Access Journals (Sweden)

    Ponniah I

    2005-01-01

    Full Text Available Salivary duct carcinoma is a rare high-grade neoplasm that more frequently affects the parotid gland. Though neoplasms of this type are infrequent in minor salivary glands, they are less aggressive and may lead to early diagnosis before distant metastases could occur. Salivary duct carcinoma is also the most frequent epithelial component of carcinosarcoma. The present article reports a case of SDC of the palate in a 26-year-old male and discusses SDC as a malignant epithelial component in carcinosarcoma.

  7. Re-thinking residential mobility

    Science.gov (United States)

    van Ham, Maarten; Findlay, Allan M.

    2015-01-01

    While researchers are increasingly re-conceptualizing international migration, far less attention has been devoted to re-thinking short-distance residential mobility and immobility. In this paper we harness the life course approach to propose a new conceptual framework for residential mobility research. We contend that residential mobility and immobility should be re-conceptualized as relational practices that link lives through time and space while connecting people to structural conditions. Re-thinking and re-assessing residential mobility by exploiting new developments in longitudinal analysis will allow geographers to understand, critique and address pressing societal challenges. PMID:27330243

  8. Large-Scale Residential Demolition

    Science.gov (United States)

    The EPA provides resources for handling residential demolitions or renovations. This includes planning, handling harmful materials, recycling, funding, compliance assistance, good practices and regulations.

  9. Neutronics shielding analysis of the last mirror-beam duct system for a laser fusion power reactor

    International Nuclear Information System (INIS)

    Ragheb, M.M.H.; Klein, A.C.

    1981-01-01

    A Monte Carlo three-dimensional neutronics analysis for the last mirror-beam duct system for the SOLASE conceptual laser-driven fusion power reactor design is presented. Detailed geometric configurations including the reactor cavity, the two last mirrors, and the three-section two-right-angle bends duct are modeled. Measurements are given of the dimensions and compositions of the reactor components, and of neutron scalar fluxes, spatial dependencies and neutron volumetric heating rates for the cases of aluminum or Boral as laser beam duct liners, and ordinary concrete or lead mortar as shield material. A three-dimensional modeling of laser-driven reactor penetrations is employed. The particle leakage is found to be excessively high for the configuration of the conceptual design considered and the advantages and disadvantages of various solutions, such as the use of Boral as a duct liner and the use of lead mortar instead of ordinary concrete as a shield material, are considered

  10. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    climatic conditions and different air distribution systems types. Data on thermal energy and fan power was collected before and after the duct sealant...Expeditionary Warfare Center. This technology internally seals leaks in air distribution ducts by injecting a fog of aerosolized sealant particles...into a pressurized duct system. The product keeps the particles suspended within the air stream. As the duct work is pressurized, the particles

  11. Solitary intrahepatic bile-duct cyst presenting with Jaundice

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Chun, Ki Sung; Ha, Hyun Kwon; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Jun Gi

    1989-01-01

    Caroli's disease is an uncommon condition, and characterized by congenital segmental saccular dilatation of intrahepatic bile ducts. A case of Caroli's disease, manifested by only a large communicating cystic dilatation of left intrahepatic bile duct and causing extrinsic pressure over the extrahepatic bile duct, is presented. The patient was 43-year-old housewife, hospitalized because of abdominal distension and severe jaundice. To relieve jaundice and alleviate surgical intervention, percutaneous drainage of the bile-duct cyst preceded surgery

  12. Mechanisms of Lower Bile Duct Stricture in Autoimmune Pancreatitis

    OpenAIRE

    Watanabe, Takayuki; Maruyama, Masahiro; Ito, Tetsuya; Maruyama, Masafumi; Muraki, Takashi; Hamano, Hideaki; Arakura, Norikazu; Hasebe, Osamu; Kawa, Shigeyuki

    2014-01-01

    Objectives We attempted to clarify the mechanism underlying lower bile duct stricture in autoimmune pancreatitis. Methods Imaging and histologic finding of the bile duct were assessed for 73 patients with autoimmune pancreatitis to clarify whether IgG4-related biliary inflammation or pancreatic head swelling is associated with lower bile duct stricture. Results Lower bile duct stricture was found in 59 (81%) patients. Pancreatic head swelling was significantly more frequent among patients wit...

  13. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  14. ACCESSORY CYSTIC DUCT IDENTIFIED IN LAPAROSCOPIC CHOLECYSTECTOMY: A RARE CASE

    OpenAIRE

    Kumar; Kumar; Shaleen; Wasif; Amit

    2014-01-01

    We report the case of a 53 year old lady who underwent laparoscopic cholecystectomy and was found to have an accessory cystic duct close to the fundus. Careful dissection of the liver bed was done and the duct clipped preventing a bile leak. The presence of such ducts though rare should be identified during surgery to prevent potential complications.

  15. Persistent Mullerian Duct Syndrome (PMDS With Large Intraabdominal Seminoma

    Directory of Open Access Journals (Sweden)

    Della Harigovind

    2017-07-01

    Full Text Available Persistent Mullerian Duct Syndrome, a form of male pseudohermaphroditism is characterized by the presence of the Mullerian duct derivatives in an otherwise phenotypically as well as genotypically normal male. We report a case of large intra abdominal seminoma in a male patient with cryptorchidism, along with persistence of Mullerian duct derivatives (uterus.

  16. A case of fascioliasis in common bile duct

    International Nuclear Information System (INIS)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong

    1989-01-01

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct

  17. A case of fascioliasis in common bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Soo Youn; Park, Cheol Min; Chung, Kyu Byung; Lee, Chang Hong; Park, Seung Chul; Choi, Sang Yong; Lim, Han Jong [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-10-15

    A case of Fascioliasis of common bile duct is confirmed by visualization of adult fluke. Fascioliasis caused by Fasciola hepatica, is common parasitic disease in cattle and sheep. Human is an accidental host. ERCP demonstrated irregular linear conglomerated filling defects in common bile duct. Through surgical intervention, we found adult flukes of F. hepatica and adenomatous hyperplasia of common bile duct.

  18. Iatrogenic injury of an aberrant right posterior sectoral bile duct

    African Journals Online (AJOL)

    (Figs 1 and 2). A week later, an endoscopic retrograde cholangiopancreatography. (ERCP) examination was performed. This showed no filling of the right posterior sectoral ducts but normal opacification of the other ducts. (Figs 3a and b). These findings led to the diagnosis of an aberrant right posterior sectoral bile duct that ...

  19. Surgical management of Stenson's duct injury using epidural ...

    African Journals Online (AJOL)

    Surgical management of Stenson's duct injury using epidural catheter: A novel technique. ... It is in the form of ductal exposure, laceration, total severing, or crushing of the duct. These conditions are difficult to ... Many techniques have been proposed for diagnosis and management of parotid duct injuries. This article ...

  20. Termination pattern of the main and accessory pancreatic ducts ...

    African Journals Online (AJOL)

    The pancreas has the main and occasionally a patent accessory pancreatic ducts that carry secretions to the duodenum. Anatomical studies on these ducts are limited. The present study observed the anatomy of the two ducts in eighty six Tanzanians' autopsy subjects to find out if the pattern is similar to those reported from ...

  1. MR findings in thyroglossal duct cysts

    International Nuclear Information System (INIS)

    Blandino, A.; Salvi, L.; Chirico, G.; Scribano, E.; Longo, M.; Pandolfo, I.

    1990-01-01

    Two patients with thyroglossal duct cysts have been studied with CT and MR. The typical CT feature of these cystic upper-neck lesions are depicted in literature, conversely MR findings are not well known. The homogeneous high intensity on T1-weighted images, higher than simple cyst or fluid, is the most typical feature of the thyroglossal cyst. (author). 12 refs.; 5 figs

  2. Patent nasopalatine duct: a diagnostic pitfall

    NARCIS (Netherlands)

    Valstar, M.H.; van den Akker, H.P.

    2008-01-01

    We describe a patient in whom the combination of excessive air in the maxillary sinus and the presence of a patent nasopalatine duct led to misdiagnosis and subsequent treatment of a non-existent oroantral perforation. When a radiograph indicates that antral involvement during removal of a maxillary

  3. Whistler instability in a magnetospheric duct

    Energy Technology Data Exchange (ETDEWEB)

    Talukdar, I.; Tripathi, V.K. (Indian Inst. of Tech., New Delhi (India). Dept. of Physics); Jain, V.K. (Jawaharlal Nehru Univ., New Delhi (India). School of Environmental Sciences)

    1989-04-01

    A whistler wave propagating through a preformed magnetospheric duct is susceptible to growth/amplification by an electron beam. The interaction is non-local and could be of Cerenkov or slow-cyclotron type. First-order perturbation theory is employed to obtain the growth rate for flat and Gaussian beam densities. (author).

  4. [Cervical thoracic duct cyst: An uncommon entity].

    Science.gov (United States)

    Carreira-Delgado, Manuel; Fernández-Rodríguez, Elvira; Martínez-Míguez, Marta; Álvarez-Martín, María Jesús; Nuño Vázquez-Garza, José Manuel

    2017-12-01

    Cervical thoracic duct cysts are a rare anomaly. To report a case of cervical thoracic duct cyst, and perform a literature review. A 78-year-old female, with a one-year history of a left-sided asymptomatic supraclavicular cystic mass. Computerized tomography revealed a cystic mass 42mm in diameter. We performed a fine needle aspiration puncture, obtaining a thick, milky, whitish liquid. The patient underwent surgery; finding a left-sided supraclavicular cystic mass, with some lymph vessels heading towards the jugulo subclavian venous junction. We performed a ligation of these lymph vessels and resection of the mass. The histopathologic study confirmed the diagnosis of thoracic duct cyst. Diagnosis of cervical thoracic duct cyst should be suspected with a cystic lesion in the left supraclavicular region, which when perforated exudes a very distinctive thick milky, whitish liquid with a high content of lymphocytes and triglycerides. Treatment should be complete removal with ligation of the lymphatic afferent vessels. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Integrated residential photovoltaic array development

    Science.gov (United States)

    Royal, G. C., III

    1981-04-01

    Sixteen conceptual designs of residential photovoltaic arrays are described. Each design concept was evaluated by an industry advisory panel using a comprehensive set of technical, economic and institutional criteria. Key electrical and mechanical concerns that effect further array subsystem development are also discussed. Three integrated array design concepts were selected by the advisory panel for further optimization and development. From these concepts a single one will be selected for detailed analysis and prototype fabrication. The three concepts selected are: (1) An array of frameless panels/modules sealed in a T shaped zipper locking neoprene gasket grid pressure fitted into an extruded aluminum channel grid fastened across the rafters. (2) An array of frameless modules pressure fitted in a series of zipper locking EPDM rubber extrusions adhesively bonded to the roof. Series string voltage is developed using a set of integral tongue connectors and positioning blocks. (3) An array of frameless modules sealed by a silicone adhesive in a prefabricated grid of rigid tape and sheet metal attached to the roof.

  6. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  7. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  8. CT findings of thyroglossal duct cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Oh; Kim, Hong Soo; So, Hyun Soon; Nam, Mee Young; Choi, Jae Ho; Rhee, Hak Song [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    1995-05-15

    The purpose of this study was to evaluate the CT findings of thyroglossal duct cysts. Sixteen patients with pathologically proved thyroglossal duct cysts were included in the study. CT scans were assessed retrospectively for shape, size, location, density of the central portions, septations, rim enhancement, changes in the adjacent fascial planes and investment within the strap muscles in the infrahyoid cysts. Thirteen cases of thyroglossal duct cysts were seen as round or oval cystic masses, two cases of them were seen as irregular-shaped lobulated cystic masses, and one case was seen as ovoid soft tissue mass. The cysts were from 1.4 to 5.7 cm in diameter (mean, 2.6 cm). The cyst was infrahyoid in 15 cases and suprahyoid in one case. The cyst was located in midline in eight cases, off midline in four cases, and both midline and off midline in four cases. The density of the central portions ranged from 15 to 82HU (mean, 32HU). Septations were noted in four cases. Rim enhancement was seen in 14 cases (93%), and heterogeneously enhancing soft tissue mass was seen in one case. In four cases, abnormal fascial planes were observed. All but one of the infrahyoid cysts (14/15) were embedded within the strap muscles, and one case of them was located anteriorly to strap muscles. CT permits one to make the diagnosis a thyroglossal duct cyst with a high degree of accuracy, as it can differentiate thyroglossal duct cysts from the other anterior neck masses by their typical location, characteristic morphology, and investment within the strap muscles.

  9. Tolerance of bile duct to intraoperative irradiation

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Tepper, J.; Travis, E.L.

    1982-01-01

    In order to determine the effects of intraoperative radiation therapy of the bile duct and surrounding tissues, seven adult dogs were subjected to laparotomy and intraoperative irradiation with 11 MeV electrons. Two animals were treated at each dose level of 2000, 3000, and 4500 rads. A single dog which received a laparotomy and sham irradiation served as a control. The irradiation field consisted of a 5 cm diameter circle encompassing the extrahepatic bile duct, portal vein, hepatic artery, and lateral duodenal wall. The animals were followed clinically for mor than 18 months after treatment, and autopsies were performed on dogs that died to assess radiation-induced complications or tissue damage. All dogs developed fibrosis and mural thickening of the common duct, which appeared by 6 weeks following irradiation and which was dose-related, being mild at low doses and more severe at high doses. Hepatic changes were seen as early as 6 weeks after irradiation, consisting of periportal inflammation and fibrosis. The hepatic changes appeared earliest at the highest doses. Frank biliary cirrhosis eventually developed at all dose levels. Duodenal fibrosis appeared in the irradiation portal, being most severe at the highest doses and in some animals resulting in duodenal obstruction. No changes were observed in irradiated portions of portal vein and hepatic artery at any dose level. It was concluded that intraoperative radiation therapy delivered to the region of the common duct leads to ductal fibrosis, partial biliary obstruction with secondary hepatic changes, and duodenal fibrosis if bowel wall is included in the field. Clinical use of intraoperative radiation therapy to the bile duct in humans may require routine use of biliary and duodenal bypass to prevent obstructive complications

  10. CT findings of thyroglossal duct cyst

    International Nuclear Information System (INIS)

    Kim, Dong Oh; Kim, Hong Soo; So, Hyun Soon; Nam, Mee Young; Choi, Jae Ho; Rhee, Hak Song

    1995-01-01

    The purpose of this study was to evaluate the CT findings of thyroglossal duct cysts. Sixteen patients with pathologically proved thyroglossal duct cysts were included in the study. CT scans were assessed retrospectively for shape, size, location, density of the central portions, septations, rim enhancement, changes in the adjacent fascial planes and investment within the strap muscles in the infrahyoid cysts. Thirteen cases of thyroglossal duct cysts were seen as round or oval cystic masses, two cases of them were seen as irregular-shaped lobulated cystic masses, and one case was seen as ovoid soft tissue mass. The cysts were from 1.4 to 5.7 cm in diameter (mean, 2.6 cm). The cyst was infrahyoid in 15 cases and suprahyoid in one case. The cyst was located in midline in eight cases, off midline in four cases, and both midline and off midline in four cases. The density of the central portions ranged from 15 to 82HU (mean, 32HU). Septations were noted in four cases. Rim enhancement was seen in 14 cases (93%), and heterogeneously enhancing soft tissue mass was seen in one case. In four cases, abnormal fascial planes were observed. All but one of the infrahyoid cysts (14/15) were embedded within the strap muscles, and one case of them was located anteriorly to strap muscles. CT permits one to make the diagnosis a thyroglossal duct cyst with a high degree of accuracy, as it can differentiate thyroglossal duct cysts from the other anterior neck masses by their typical location, characteristic morphology, and investment within the strap muscles

  11. Development of the building integrated ducted wind turbine module

    Energy Technology Data Exchange (ETDEWEB)

    Dannecker, R.; Varela, G. Quinonez; Grant, A. [Strathclyde Univ., Dept. of Mechanical Engineering, Glasgow (United Kingdom)

    2000-07-01

    Wind is now established as a major renewable energy resource, but its exploitation is generally confined to sparsely populated areas and may in future be increasingly limited by environmental constraints. The paper describes the development of a small axial flow turbine with vertical shaft, situated in a curved duct, which is intended to be completely integrated in a high rise building in an urban environment. The design is intended to make optimal use of the differential pressures which result from wind flow around a building. A small scale model and prototypes for field trials have been tested as free standing devices and their performance shown to be competitive with conventional small machines for low power applications. The aerodynamical response to different design options is subject to computational fluid dynamic analysis and will be used in conjunction with wind tunnel testing to refine rotor, stator and duct geometries. A trial deployment will shortly commence as a demonstration project on a newly refurbished building of historical significance in the center of Glasgow. (Author)

  12. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  13. Proof tests of irradiated and unirradiated EBR-II subassembly ducts

    International Nuclear Information System (INIS)

    Ruther, W.E.; Chopra, P.S.; Lambert, J.D.B.

    1977-01-01

    A series of dynamic pressure tests have been conducted within EBR-II subassembly ducts. The tests were designed to simulate bursting of a driver-fuel element in a cluster of such elements at their burnup limit during off-normal conditions in EBR-II. The major objective of the tests was to assure that such failure, which might cause rapid release of stored fission gas, would not deform or otherwise damage subassembly ducts in a way that would hinder movement of a control rod. The test results are described

  14. A numerical investigation of laminar forced convection in a solar collector with non-circular duct

    Directory of Open Access Journals (Sweden)

    Teleszewski Tomasz Janusz

    2017-01-01

    Full Text Available This paper presents a two-dimensional numerical study to investigate laminar flow in a flat plate solar collector with non-circular duct (regular polygonal, elliptical, and Cassini oval shape featuring forced convection with constant axial wall heat flux and constant peripheral wall temperature (H1 condition. Applying the velocity profile obtained for the duct laminar flow, the energy equation was solved exactly for the constant wall heat flux using the Boundary Element Method (BEM. Poiseuille and Nusselt numbers were obtained for flows having a different number of geometrical factors. The results are presented and discussed in the form of tables and graphs. The area goodness factor and volume goodness factor are calculated. The predicted correlations for Poiseuille and Nusselt numbers may be a very useful resource for the design and optimization of solar collectors with non-circular ducts.

  15. A numerical investigation of laminar forced convection in a solar collector with non-circular duct

    Science.gov (United States)

    Janusz Teleszewski, Tomasz

    2017-11-01

    This paper presents a two-dimensional numerical study to investigate laminar flow in a flat plate solar collector with non-circular duct (regular polygonal, elliptical, and Cassini oval shape) featuring forced convection with constant axial wall heat flux and constant peripheral wall temperature (H1 condition). Applying the velocity profile obtained for the duct laminar flow, the energy equation was solved exactly for the constant wall heat flux using the Boundary Element Method (BEM). Poiseuille and Nusselt numbers were obtained for flows having a different number of geometrical factors. The results are presented and discussed in the form of tables and graphs. The area goodness factor and volume goodness factor are calculated. The predicted correlations for Poiseuille and Nusselt numbers may be a very useful resource for the design and optimization of solar collectors with non-circular ducts.

  16. Fluctuating pressure forces acting on the hot gas duct of a high temperature reactor

    International Nuclear Information System (INIS)

    Achenbach, E.

    1977-01-01

    In the hot gas ducts of high temperature reactors high velocities (70 0 -bends of segmental design; 90 0 -bends, mitred; 90 0 -mitred, rectangular channel. For comparison the pressure fluctuations of the straight tube were also determined. The experiments were conducted in air, pressurized air and helium. The pressure fluctuations were measured by means of condenser microphones. (Auth.)

  17. Optimization of endwall contouring in axial compressor S-shaped ducts

    Directory of Open Access Journals (Sweden)

    Jin Donghai

    2015-08-01

    Full Text Available This paper presents a numerical investigation of the potential aerodynamic benefits of using endwall contouring in a fairly aggressive duct with six struts based on the platform for endwall design optimization. The platform is constructed by integrating adaptive genetic algorithm (AGA, design of experiments (DOE, response surface methodology (RSM based on the artificial neural network (ANN, and a 3D Navier–Stokes solver. The visual analysis method based on DOE is used to define the design space and analyze the impact of the design parameters on the target function (response. Optimization of the axisymmetric and the non-axisymmetric endwall contouring in an S-shaped duct is performed and evaluated to minimize the total pressure loss. The optimal ducts are found to reduce the hub corner separation and suppress the migration of the low momentum fluid. The non-axisymmetric endwall contouring is shown to remove the separation completely and reduce the net duct loss by 32.7%.

  18. Transition duct with divided upstream and downstream portions

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier; Dillard, Daniel Jackson; Flanagan, James Scott

    2015-07-14

    Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing the upstream portion and the downstream portion.

  19. Parotid Duct Repair with Intubation Tube: Technical Note

    Science.gov (United States)

    Öztürk, Muhammed Beşir; Barutca, Seda Asrufoğlu; Keskin, Elif Seda; Atik, Bekir

    2017-01-01

    The parotid duct can be damaged in traumatic injuries and surgical interventions. Early diagnosis and treatment of a duct injury is of great importance because complications such as sialocele and salivary gland fistula may develop if the duct is not surgically repaired. We think the cuff of an intubation tube is an ideal material in parotid duct repair, because of its technical characteristics, easiness of availability, and low-cost. In this paper, we described the use of the cuff cannula of an intubation tube for the diagnosis and treatment of parotid duct laceration, as a low-cost and easy to access material readily available in every operating room. PMID:28713751

  20. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  1. Dispersion properties of ducted whistlers, generated by lightning discharge

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2005-06-01

    Full Text Available Whistler-mode wave propagation in magnetospheric ducts of enhanced cold plasma density is studied. The case of the arbitrary ratio of the duct radius to the whistler wavelength is considered, where the ray-tracing method is not applicable. The set of duct eigenmodes and their spatial structure are analysed and dependencies of eigenmode propagation properties on the duct characteristics are studied. Special attention is paid to the analysis of the group delay time of one-hop propagation of the whistler wave packet along the duct. We found that, in contrast to the case of a wide duct, the group delay time in a rather narrow duct decreases as the eigenmode number increases. The results obtained are suggested for an explanation of some types of multi-component whistler signals.

  2. SNM holdup assessment of Los Alamos exhaust ducts

    International Nuclear Information System (INIS)

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of 235 U in a duct servicing a shut-down uranium-machining facility to 39 g of 239 Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of 235 U in a duct servicing analytical laboratories to 1 g of 235 U and 1 g of 239 Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern

  3. Understanding the information dynamics of medication administration in residential aged care facilities (RACFs): a prerequisite for design of effective ICT systems.

    Science.gov (United States)

    Tariq, Amina; Georgiou, Andrew; Westbrook, Johanna

    2013-01-01

    Medication information is a critical part of the information required to ensure residents' safety in the highly collaborative care context of RACFs. Studies report poor medication information as a barrier to improve medication management in RACFs. Research exploring medication work practices in aged care settings remains limited. This study aimed to identify contextual and work practice factors contributing to breakdowns in medication information exchange in RACFs in relation to the medication administration process. We employed non-participant observations and semi-structured interviews to explore information practices in three Australian RACFs. Findings identified inefficiencies due to lack of information timeliness, manual stock management, multiple data transcriptions, inadequate design of essential documents such as administration sheets and a reliance on manual auditing procedures. Technological solutions such as electronic medication administration records offer opportunities to overcome some of the identified problems. However these interventions need to be designed to align with the collaborative team based processes they intend to support.

  4. Isolated chyle duct injury in blunt trauma.

    Science.gov (United States)

    Dissanaike, Sharmila; Griswold, John A; Halldorsson, Ari; Frezza, Eldo E

    2006-02-01

    We present a case of a patient sustaining an isolated injury to the right main branch of the cysterna chyli due to a high-speed motor vehicle accident. A 42-year-old man presented after a high-speed collision. CT revealed a collection of hypodense fluid in the gallbladder fossa, which was the clue to take him to the OR. We proceeded to laparoscopic exploration, and based on the milky white color of the fluid, identified a chyle leak. In an open fashion, the retroperitoneum was explored and the injury was identified as disruption of the right lumbar branch entering the cisterna chyli, and this was ligated with silk ties. Chyle duct injury secondary to blunt trauma is a rare finding. The use of CT imaging can identify this injury. Laparoscopy can confirm the injury. Open ligation of the injured duct is the best treatment.

  5. Acoustic Power Transmission Through a Ducted Fan

    Science.gov (United States)

    Envia, Ed

    2016-01-01

    For high-speed ducted fans, when the rotor flowfield is shock-free, the main contribution to the inlet radiated acoustic power comes from the portion of the rotor stator interaction sound field that is transmitted upstream through the rotor. As such, inclusion of the acoustic transmission is an essential ingredient in the prediction of the fan inlet noise when the fan tip relative speed is subsonic. This paper describes a linearized Euler based approach to computing the acoustic transmission of fan tones through the rotor. The approach is embodied in a code called LINFLUX was applied to a candidate subsonic fan called the Advanced Ducted Propulsor (ADP). The results from this study suggest that it is possible to make such prediction with sufficient fidelity to provide an indication of the acoustic transmission trends with the fan tip speed.

  6. Renal collecting duct carcinoma in a dog.

    Science.gov (United States)

    Kobayashi, N; Suzuki, K; Shibuya, H; Sato, T; Aoki, I; Nagashima, Y

    2008-07-01

    An 8-year-old, male, mongrel dog developed severe cough and anorexia and died within 3 months. Autopsy revealed an invasive grayish-white mass in the right kidney and multiple nodules in the lungs, thoracic wall, and spleen. Histologically, the renal mass and the other nodules were mainly composed of papillotubular structures lined by oval-to-polygonal pleomorphic cells. The cells were reactive with DBA, PNA, and UEA-1 lectins and positive for vimentin but negative for CD10 and high molecular weight cytokeratin. Because of its histological, histochemical, and immunohistochemical similarities with human collecting duct carcinoma (CDC), a diagnosis of renal collecting duct carcinoma with pulmonary, thoracic, and splenic metastases was established. To our knowledge, this is the first case report of CDC in animals.

  7. CT findings of common bile duct stones

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Byung Hee; Lee, Sang Kil; Kim, Jong Sung; Joo, Kyung Bin; Cho, On Koo; Hahm, Chang Kok; Kim, Yong Il [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1992-11-15

    A retrospective study on computed tomographic (CT) findings in 35 surgically confirmed cases of common bile duct stones was performed to analyze the characteristic CT findings. Choledocholithiasis was correctly diagnosed by CT in 33 out of 35 cases (sensitivity, 94.3%) and among these CT demonstrated calculi of high attenuation in 32 and of soft tissue density in one case. The thirty two included 23 totally calcified. 5 rim calcified and 4 laminated stones. The target sign was observed in 30 out of 33 CT positive cases (90.1%). We concluded that CT is an accurate modality in the diagnosis of common bile duct stones with its' reliable display of the calcified or the laminated stone itself and its' characteristic target sign.

  8. CT findings of common bile duct stones

    International Nuclear Information System (INIS)

    Koh, Byung Hee; Lee, Sang Kil; Kim, Jong Sung; Joo, Kyung Bin; Cho, On Koo; Hahm, Chang Kok; Kim, Yong Il

    1992-01-01

    A retrospective study on computed tomographic (CT) findings in 35 surgically confirmed cases of common bile duct stones was performed to analyze the characteristic CT findings. Choledocholithiasis was correctly diagnosed by CT in 33 out of 35 cases (sensitivity, 94.3%) and among these CT demonstrated calculi of high attenuation in 32 and of soft tissue density in one case. The thirty two included 23 totally calcified. 5 rim calcified and 4 laminated stones. The target sign was observed in 30 out of 33 CT positive cases (90.1%). We concluded that CT is an accurate modality in the diagnosis of common bile duct stones with its' reliable display of the calcified or the laminated stone itself and its' characteristic target sign

  9. Residential space heating systems: energy conservation and economics

    Energy Technology Data Exchange (ETDEWEB)

    O' Neal, D.L.

    1979-01-01

    Annual energy use for residential space heating was 8.6 Quads in 1975. This accounted for over 50% of the energy used in the residential sector and 12% of energy used in the U.S. that year. Because residential space heating accounts for such a large share of energy use, improvements in new space heating systems could have significant long-term conservation effects. Several energy-saving design changes in residential space heating systems are examined to determine their energy conservation potential and cost effectiveness. Both changes in conventional and advanced systems are considered. Conventional design changes include options such as the flue damper, sealed combustion, electric ignition and improved heat exchangers. Some of the advanced designs include the gas heat pump, pulse combustion furnace, and dual speed compressor heat pump. The energy use and cost estimates are developed from current literature, heating and equipment manufacturers and dealers, and discussions with individuals doing research and testing on residential space heating equipment. Results indicate that implementation of conventional design changes can reduce energy use of representative gas, oil, and electric space heating systems by 26, 20, and 57%, respectively. These changes increase the capital cost of the systems by 27, 16, and 26%. Advanced gas and electric space heating systems can reduce energy use 45 and 67%, respectively. However, the advanced systems cost 80 and 35% more than representative gas and electric systems.

  10. Iatrogenic injury to the common bile duct.

    Science.gov (United States)

    Buturovic, Sead

    2014-08-01

    The formation of gallstones in the gall bladder is very common. It is now considered that approximately 10% to 15% of the adult population has gallstones. It is more frequent in women than men. age, sex, diet, sudden weight loss, etc. According to the report of the US National Institute of Health, it is estimated that 6.3 million men and 14.2 million women, aged 20-74 years in the United States has calculosis of the gallbladder, due to which every year is performed about 700,000 cholecystectomy. Male patient, aged about 40 years, admitted at the Clinic and laparoscopic surgery was performed in our department for chronic, as multiple, symptomatic gallbladder calculi. Intraoperative findings showed chronically inflamed, curled gall bladder, and wall thickening. After the first postoperative day there is no content in the drain bag and it is taken out, and the patient leaves the hospital without any problems. The seventh post-operative day occurred abdominal pain, weakness and fatigue, with striking yellow skin and visible mucous membranes. Clinical, laboratory and echo determined abdomen full of fluids, so it was suspected lesion of the bile duct. Urgent revision was performed. Intraoperative was found a lesion of the common bile duct in the form of a complete interruption. Created is anastomosis through transhepatic drain according to Pradera. Early and late postoperative flow was entirely normal with normal laboratory and echofindings. Control, contrast imaging through a drain showed the orderly flow of extrahepatic bile ducts, with minimal extravasation of contrast. At the Department of Surgery of General Hospital in Konjic laparoscopic cholecystectomy is performed since 1999. In the beginning it was done by three trocars (European style), and later, in order to prevent complications or injury of the bile duct is performed surgery with four trocars (American style). The number of complicated procedures in our hospital does not differ from similar indicators in

  11. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  12. Heat Transfer Enhancement In a Ribbed Duct

    Directory of Open Access Journals (Sweden)

    J.M. Jalil

    2006-12-01

    Full Text Available The rib enhancement of heat transfer in a duct is studied numerically and experimentally, where hot air passes through a duct (0.04 x 0.16 x 1.15 m3 with different rib arrangement. The arranments are lower 12-rib arrangement; upper 12 rib arrangement and 24 rib staggered arrangement. The staggered arrangement gives better performance than the others. Also, the angle of attack was studied for lower arrangement, three different values were tested (45°, 60° and 90°. Angle of 60° gives better performance. Numerically, the three-dimension continuity, Navier-Stokes and energy   by finite volume method of flow of air through (0.04 x 0.16 x 0.6 m3. Validation of the code was performed by comparing the numerical result with the results obtained experimentally for staggered arrangement only. The agreement seems acceptable. The numerical studies were extended to study the case of cold air passing through hot ribbed duct.

  13. Primary tuberculosis of cystic duct lymph node.

    Science.gov (United States)

    Ghazanfar, Aamir; Asghar, Afifa; Khan, Naqeeb Ullah; Hassan, Iram

    2017-06-16

    Tuberculosis (TC) is very common and significant cause of morbidity and mortality worldwide. Isolated cystic duct lymph node TC cases without involvement of gallbladder are exceedingly rare. It is difficult to diagnose preoperatively because of lack of characteristic signs and symptoms of TC. We report a man aged 45 years who presented with right upper abdominal pain since 1week. It was associated with nausea and postprandial fullness. There was no evidence of jaundice and lymphadenopathy. Abdominal examination showed moderate right upper quadrant tenderness with positive Murphy's sign and splenomegaly but no signs of peritonism. Abdomen ultrasound revealed sludge in gallbladder, dilated pancreatic duct, coarse exotexture of liver, splenomegaly and no lymphadenopathy. He underwent laparoscopic cholecystectomy; histological report showed chronic caseating granulomatous lymphadenitis with Langhans type of giant cells in lymph node near cystic duct with chronic cholecystitis of gallbladder. Standard antituberculosis therapy was given for 12 months. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Sorption of organic gases in residential rooms

    Science.gov (United States)

    Singer, Brett C.; Hodgson, Alfred T.; Hotchi, Toshifumi; Ming, Katherine Y.; Sextro, Richard G.; Wood, Emily E.; Brown, Nancy J.

    Experiments were conducted to characterize organic gas sorption in residential rooms studied "as-is" with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink-diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms.

  15. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  16. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, Malachi; Ayyagari, Raj R. [Yale School of Medicine, Yale New Haven Hospital, New Haven, CT (United States); Division of Interventional Radiology, Department of Radiology, 789 Howard Avenue, P.O. Box 208042, New Haven, CT (United States)

    2015-06-15

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  17. Modelling the dynamics of the cogeneration power plant gas-air duct

    Directory of Open Access Journals (Sweden)

    Аnatoliy N. Bundyuk

    2014-12-01

    Full Text Available Introducing into wide practice the cogeneration power plants (or CHP is one of promising directions of the Ukrainian small-scale power engineering development. Thermal and electric energy generation using the same fuel kind can increase the overall plant efficiency. That makes it appropriate to use CHPs at compact residential areas, isolated industrial enterprises constituting one complex with staff housing area, at sports complexes, etc. The gas-air duct of the cogeneration power plant has been considered as an object of the diesel-generator shaft velocity control. The developed GAD mathematical model, served to analyze the CHP dynamic characteristics as acceleration curves obtained under different external disturbances in the MathWorks MATLAB environment. According to the electric power generation technology requirements a convenient transition process type has been selected, with subsequent identification of the diesel-generator shaft rotation speed control law.

  18. Analysis of Dual Rotating Rake Data from the NASA Glenn Advanced Noise Control Fan Duct with Artificial Sources

    Science.gov (United States)

    Dahl, Milo D.; Sutliff, Daniel L.

    2014-01-01

    The Rotating Rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. Initially, the mode amplitudes and phases were quantified from a single rake measurement at one axial location. To directly measure the modes propagating in both directions within a duct, a second rake was mounted to the rotating system with an offset in both the axial and the azimuthal directions. The rotating rake data analysis technique was then extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode levels at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode amplitudes for the modes propagating in both directions within the duct. Validation experiments have been conducted using artificial acoustic sources. Results are shown for the measurement of the standing waves in the duct from sound generated by one and two acoustic sources that are separated into the component modes propagating in both directions within the duct. Measured reflection coefficients from the open end of the duct are compared to analytical predictions.

  19. Analysis of chemical-reaction-coupled mass and heat transport phenomena in a methane reformer duct for PEMFCs

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Jinliang; Sunden, Bengt [Lund University, Lund (Sweden). Department of Energy Sciences, Faculty of Engineering; Ren, Fuan [Marine Engineering College, Dalian Maritime University, Dalian (China)

    2007-02-15

    Mass, heat and momentum transport processes are coupled with catalytic chemical reactions in a methane steam reforming duct. It is often found that endothermic and exothermic reactions in the ducts are strongly integrated by heat transfer from adjacent catalytic combustion ducts. In this paper, a three-dimensional calculation method is developed to simulate and analyze reforming reactions of methane, and the effects on various transport processes in a steam reforming duct. The reformer conditions such as mass balances associated with the reforming reactions and gas permeation to/from the porous catalyst reforming layer are applied in the analysis. The predicted results are presented and discussed for a composite duct consisting of a porous catalyst reaction layer, the fuel gas flow duct and solid layers. Parametric studies are conducted to reveal the importance of reformer designs and operating conditions. The results show that the variables, such as porous layer configuration, temperature and catalyst loading, have significant effects on the transport processes and reformer performance. (author)

  20. [Therapeutic Residential Care for Children and Youth: A Consensus Statement of the International Work Group on Therapeutic Residential Care].

    Science.gov (United States)

    Whittaker, James K; Holmes, Lisa; Del Valle, Jorge F; Ainsworth, Frank; Andreassen, Tore; Anglin, James; Bellonci, Christopher; Berridge, David; Bravo, Amaia; Canali, Cinzia; Courtney, Mark; Currey, Laurah; Daly, Daniel; Gilligan, Robbie; Grietens, Hans; Harder, Annemiek; Holden, Martha; James, Sigrid; Kendrick, Andrew; Knorth, Erick; Lausten, Mette; Lyons, John; Martin, Eduardo; McDermid, Samantha; McNamara, Patricia; Palareti, Laura; Ramsey, Susan; Sisson, Kari; Small, Richard; Thoburn, June; Thompson, Ronald; Zeira, Anat

    2017-08-01

    Therapeutic Residential Care for Children and Youth: A Consensus Statement of the International Work Group on Therapeutic Residential Care. In many developed countries around the world residential care interventions for children and adolescents have come under increasing scrutiny. Against this background an international summit was organised in England (spring 2016) with experts from 13 countries to reflect on therapeutic residential care (TRC). The following working definition of TRC was leading: “Therapeutic residential care involves the planful use of a purposefully constructed, multi-dimensional living environment designed to enhance or provide treatment, education, socialization, support, and protection to children and youth with identified mental health or behavioral needs in partnership with their families and in collaboration with a full spectrum of community based formal and informal helping resources”. The meeting was characterised by exchange of information and evidence, and by preparing an international research agenda. In addition, the outlines of a consensus statement on TRC were discussed. This statement, originally published in English and now reproduced in a Spanish translation, comprises inter alia five basic principles of care that according to the Work Group on Therapeutic Residental Care should be guiding for residential youth care provided at any time.

  1. Occupational safety issues in residential construction surveyed in Wisconsin, United States.

    Science.gov (United States)

    Choi, Sang D; Carlson, Kathryn

    2014-01-01

    Residential construction is a high-risk industry in the U.S. due to the exposure to work-related safety hazards and fall injuries. This study aimed to examine the safety training and safe work practices of construction workers within the small residential construction industry. In order to achieve the study objectives, a survey was designed and sent to approximately 200 Wisconsin based residential construction contractors. About one third of the respondents stated that they did not have any form of safety programs. The study indicated that the most common types of work-related injuries in residential construction were slips/trips/falls and cuts/lacerations. The survey findings also suggested that the residential construction contractors needed to increase the utilization of fall protection safety equipment. Further education and subject matter expert training could provide benefits to improve occupational safety and health of the small business workforce in the residential construction industry.

  2. Endoscopic treatment for complex biliary and pancreatic duct injuries

    Directory of Open Access Journals (Sweden)

    Simon Bouchard

    2014-01-01

    Full Text Available Severe injuries of biliary or pancreatic ducts are associated with significant morbidity and mortality. Severe bile duct injuries such as major biliary leaks, complete transection, or complete occlusion of bile ducts can be grouped under the term complex bile duct injuries (CBDI. In the spectrum of pancreatic duct injuries, disconnected pancreatic duct syndrome (DPDS represents the most severe form and most often occurs after a severe episode of acute pancreatitis. Treatment of these complex injuries is quite challenging and for many years surgical management has been considered the treatment of choice. However, in the past few years, some studies have reported the successful management of CBDI or DPDS using endoscopic procedures alone or in combination with a percutaneous approach. In this review, we detail the endoscopic or combined endoscopic/percutaneous treatment possibilities for CBDI and DPDS.

  3. Establishing the soundness of administrative spatial units for operationalising the active living potential of residential environments: an exemplar for designing optimal zones

    Directory of Open Access Journals (Sweden)

    Riva Mylène

    2008-07-01

    Full Text Available Abstract Background In health and place research, definitions of areas, area characteristics, and health outcomes should ideally be coherent with one another. Yet current approaches for delimiting areas mostly rely on spatial units "of convenience" such as census tracts. These areas may be homogeneous along socioeconomic conditions but heterogeneous along other environmental characteristics. This heterogeneity can lead to biased measurement of environment characteristics and misestimation of area effects on health. The objective of this study was to assess the soundness of census tracts as units of analysis for measuring the active living potential of environments, hypothesised to be associated with walking. Results Starting with data at the smallest census area level available, zones homogeneous along three indicators of active living potential, i.e. population density, land use mix, and accessibility to services were designed. Delimitation of zones ensued from statistical clustering of the smallest areas into seven clusters or "types of environment". Mapping of clusters into a GIS led to the delineation of 898 zones characterised by one of seven types of environment, corresponding to different levels of active living potential. Homogeneity of census tracts along indicators of active living potential varied. A greater proportion (83% of variation in accessibility to services was attributable to differences between census tracts suggesting within-tract homogeneity along this variable. However, census tracts were heterogeneous with respect to population density and land use mix where a greater proportion of the variation was attributable to within-tract differences. About 55% of tracts were characterised by a combination of three or more "types of environment" suggesting substantial within-tract heterogeneity in the active living potential of environments. Conclusion Soundness of census tracts for measuring active living potential may be limited

  4. Clearance of refractory bile duct stones with extracorporeal shockwave lithotripsy

    OpenAIRE

    Ellis, R; Jenkins, A; Thompson, R; Ede, R

    2000-01-01

    BACKGROUND—Extracorporeal shockwave lithotripsy (ESWL) has been used since the mid-1980s to fragment bile duct stones which cannot be removed endoscopically. Early machines required general anaesthesia and immersion in a waterbath.
AIMS—To investigate the effectiveness of the third generation Storz Modulith SL20 lithotriptor in fragmenting bile duct stones that could not be cleared by mechanical lithotripsy.
METHODS—Eighty three patients with retained bile duct stones were treated. All patien...

  5. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  6. Squamous Cell Carcinoma of the Distal Common Bile Duct

    OpenAIRE

    Jain A; Juneja M; Naik S; Sharma S; Kapoor S; Sewkani A; Varshney S

    2005-01-01

    CONTEXT: Squamous cell carcinoma of the biliary tree is rare. Although few cases of squamous cell carcinoma of the intrahepatic bile-duct and gallbladder have been reported, until today, only four cases of squamous cell carcinoma of the extrahepatic bile duct have been reported in the literature. CASE REPORT: We present a case of squamous cell carcinoma of the distal common bile duct presenting with obstructive jaundice in a 60-year-old male which was successfully managed by a Whipple's pancr...

  7. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    Science.gov (United States)

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  8. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    Science.gov (United States)

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  9. Experimental Research and Modeling of Particle Deposition in Ventilation Ducts

    Directory of Open Access Journals (Sweden)

    Hongming Fan

    2013-01-01

    Full Text Available The model to predict particle deposition velocity on rough walls in fully developed turbulent duct flows has been developed in previous studies. For particle deposition model boundary conditions, it is assumed that the concentration of the particle is zero on the surface and the resuspension velocity is constant. However, the resuspension velocity may not be constant with the increase in mass of the deposited dust. To analyze the behavior of resuspension in air flow, a set of experiments were designed and conducted. Results showed that there was a linear relationship between the mass of resuspension and deposited dust. Also, the particle deposition model was improved by adding a resuspension item to the equation, and the steady-state equation was developed into a time-varying equation. The analysis results are presented in this paper.

  10. Liquid films flowing concurrently with air in horizontal duct, 4

    International Nuclear Information System (INIS)

    Fukano, Tohru; Takamatsu, Yasuo; Akenaga, Hiroshi; Ikeda, Masayoshi; Itoh, Akihiko; Kuriwaki, Tessho.

    1984-01-01

    The effect of the aspect ratio of the duct cross-section on a liquid film flowing concurrently with an air stream was investigated using three horizontal ducts. The dimensions of the duct are 10 mm x 40 mm (height x width), 40 mm x 40 mm and 10 mm x 80 mm. The results are summarized as follows: The boundary of flow patterns between the pebble wave flow and the disturbance wave flow strongly depends on the duct height. On the other hand, the boundary between a smooth surface flow and a two-dimensional wave flow as well as the nonwetting regime depends mainly on the duct width. The reason is that the volumetric flux of the liquid flow in the vicinity of the side walls of the duct is considerably larger than that in the central part of the duct width due to the formation of meniscus. Therefore, only the experimental values for the film parameters obtained at the central part of duct width are useful for comparison with the theoretical results obtained by the assumption that the flow is two-dimensional, even if the aspect ratio of duct seems to be sufficiently small. (author)

  11. Flexible metallic seal for transition duct in turbine system

    Science.gov (United States)

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2014-04-22

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a flexible metallic seal contacting the interface member to provide a seal between the interface member and the turbine section.

  12. Duct Leakage Modeling in EnergyPlus and Analysis of Energy Savings from Implementing SAV with InCITeTM

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig; Sherman, Max

    2010-03-01

    This project addressed two significant deficiencies in air-handling systems for large commercial building: duct leakage and duct static pressure reset. Both constitute significant energy reduction opportunities for these buildings. The overall project goal is to bridge the gaps in current duct performance modeling capabilities, and to expand our understanding of air-handling system performance in California large commercial buildings. The purpose of this project is to provide technical support for the implementation of a duct leakage modeling capability in EnergyPlus, to demonstrate the capabilities of the new model, and to carry out analyses of field measurements intended to demonstrate the energy saving potential of the SAV with InCITeTM duct static pressure reset (SPR) technology. A new duct leakage model has been successfully implemented in EnergyPlus, which will enable simulation users to assess the impacts of leakage on whole-building energy use and operation in a coupled manner. This feature also provides a foundation to support code change proposals and compliance analyses related to Title 24 where duct leakage is an issue. Our example simulations continue to show that leaky ducts substantially increase fan power: 10percent upstream and 10percent downstream leakage increases supply fan power 30percent on average compared to a tight duct system (2.5percent upstream and 2.5percent downstream leakage). Much of this increase is related to the upstream leakage rather than to the downstream leakage. This does not mean, however, that downstream leakage is unimportant. Our simulations also demonstrate that ceiling heat transfer is a significant effect that needs to be included when assessing the impacts of duct leakage in large commercial buildings. This is not particularly surprising, given that ?ceiling regain? issues have already been included in residential analyses as long as a decade ago (e.g., ASHRAE Standard 152); mainstream simulation programs that are

  13. Applying power electronics to residential HVAC

    International Nuclear Information System (INIS)

    Sulfstede, L.

    1991-01-01

    This paper outlines several of the market and application issues bearing on the economics residential variable speed air conditioners and heat pumps. Technical details of capacity modulized systems have been avoided, along with design issues and tradeoffs involving power semiconductors, motor torque and speed control strategies- and silicon integration for these applications. The intention is to provoke new creative technical solutions but perhaps more importantly, to involve new marketing strategies that will develop the mature potential of air conditioning products containing power electronics to enable them to generate the tough HVAC market, competing successfully against conventional systems

  14. Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

    Science.gov (United States)

    Eichenberg, Dennis J.; Emerson, Dawn C.; Gallo, Christopher A.; Thompson, William K.

    2011-01-01

    This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

  15. Fluorescent Method for Observing Intravascular Bonghan Duct

    Directory of Open Access Journals (Sweden)

    Byung-Cheon Lee

    2005-12-01

    Full Text Available Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

  16. Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size.

    Science.gov (United States)

    Goreczny, Sebstian; Morgan, Gareth J; Dryzek, Pawel

    2016-03-01

    Despite several reports describing echocardiography for the guidance of ductal closure, two-dimensional angiography remains the mainstay imaging tool; three-dimensional rotational angiography has the potential to overcome some of the drawbacks of standard angiography, and reconstructed image overlay provides reliable guidance for device placement. We describe arterial duct closure solely from venous approach guided by live three-dimensional image overlay.

  17. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  18. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    International Nuclear Information System (INIS)

    Wilhelm, K.E.; Grabolle, B.; Urbach, H.; Tolba, R.; Schild, H.; Paulsen, F.

    2006-01-01

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted without major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency

  19. Back-pressure effects on unsteadiness of separation shock in a rectangular duct at Mach 3

    Science.gov (United States)

    Xiong, Bing; Fan, Xiao-qiang; Wang, Yi; Zhou, Liang; Tao, Yuan

    2017-12-01

    To evaluate back-pressure effects on unsteadiness of separation shock in a rectangular duct, some test cases were designed and conducted in a supersonic air-breathing wind tunnel. High-speed Schlieren technique and high-frequency pressure measurements were utilized for data acquisition. Different back-pressure levels were applied by changing downstream throttling ratio. Some parameters for estimating canonical separation flows, such as zero-crossing frequency and intermittency, have been introduced to analyze the duct separation flow. The experimental results show that the separation shock oscillation frequencies increase and the intermittent region lengths decrease with the increasing back-pressure level. A comparison between the unsteadiness of shock/boundary layer interactions for the canonical flow and the duct internal flow were made. It is found that the normalized Strouhal number for the duct internal separation flow ranges from 0.01 to 0.03, which share the similar range with canonical separation flows. That is to say, the physics of separation shock unsteadiness is similar over a wide range of interaction flows, which may share the inherent flow mechanism.

  20. Serum gamma glutamyl transferase as a specific indicator of bile duct lesions in the rat liver.

    Science.gov (United States)

    Leonard, T B; Neptun, D A; Popp, J A

    1984-08-01

    Serum gamma-glutamyl transferase (GGT), a marker of hepatic injury used extensively in humans, has been used rarely in rats because its specificity has not been previously defined. Studies were designed for investigation of the specificity of serum GGT activity with the use of cell type specific hepatotoxicants in Fischer 344 rats. Single necrogenic doses of CCl4, allyl alcohol (AA), and alpha-naphthylisothiocyanate (ANIT) were used to produce cell specific injury in centrilobular hepatocytes, periportal hepatocytes, and bile duct cells, respectively. Administration of CCl4 markedly increased serum activities of alanine aminotransferase (ALT), alkaline phosphatase (AP), and serum bile acid concentrations within 24 hours but had no effect on serum GGT activity. ANIT treatment increased serum GGT and AP activities and bile acid concentration 24 hours following administration. Allyl alcohol administration increased serum ALT activity but had no effect on GGT activity. Administration of ANIT in the diet at 0.01%, 0.022%, 0.047%, and 0.1% for 2, 4, and 6 weeks produced dose- and time-dependent increases in serum GGT activity which strongly correlated with quantitative increases in hepatic bile duct volume, which was determined morphometrically. These observations support the use of serum GGT activity in the rat as diagnostic of bile duct cell necrosis when increases are detected shortly after the insult and as an indicator of possible bile duct hyperplasia.

  1. Numerical study of laminar magneto-convection in a differentially heated square duct

    Science.gov (United States)

    Tassone, A.; Giannetti, F.; Caruso, G.

    2017-01-01

    Magnetohydrodynamic pressure drops are one of the main issues for liquid metal blanket in fusion reactors. Minimize the fluid velocity at few millimeters per second is one strategy that can be employed to address the problem. For such low velocities, buoyant forces can effectively contribute to drive the flow and therefore must be considered in the blanket design. In order to do so, a CFD code able to represent magneto-convective phenomena is required. This work aims to gauge the capability of ANSYS© CFX-15 to solve such cases. The laminar flow in a differentially heated duct was selected as validation benchmark. A horizontal and uniform magnetic field was imposed over a square duct with a linear and constant temperature gradient perpendicular to the field. The fully developed flow was analyzed for Gr = 105 and Hartmann number (M) ranging from 102 to 103. Both insulating and conducting duct walls were considered. Strong dampening of the flow in the center of the duct was observed, whereas high velocity jets appeared close to the walls parallel to the magnetic field. The numerical results were validated against theoretical and numerical results founding an excellent agreement.

  2. The estimation of Helmholtz resonator and active noise control to predict noise reduction of fan in an air duct

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2015-01-01

    Full Text Available Aims: The main goal of this paper was to evaluate the effectiveness of Helmholtz resonator in noise reduction of duct equipped with active noise control (ANC. Materials and Methods: Noise frequency band was produced by a propeller fan, which was spread into a plexiglas duct. The noise was formed by digital signal processing (DSP to estimate the anti-noise which spreads along the duct to postpone the primary noise as a response to DSP. In this method, fan noise was recorded with a microphone. The anti-noise with the same amplitude was reproduced, and the reverse phase postpones the original noise at the primary noise path by a speaker. The designed Helmholtz resonator was installed on the duct for detecting the reduction noise at the tonal interest frequency of 300 Hz. Helmholtz resonators can give sound attenuation at a narrowband of frequencies, close to its resonance frequency. The overall decline changes were estimated in order to predict the effectiveness of the method. Results: In this study, a noise discount of 5-10 dB at the peak frequencies has been observed. The peak frequency of residual noise has reduced 5-10 dB. The value is more than applying ANC system solely to optimize noise lessening of produced noise by a fan along the designed duct. Conclusion: Use of Helmholtz resonator is proposed as a suggestion to optimize the process of noise fall in duct. This study is concerned with the attenuation of tonal noise transmission in ducts by using ANC and side branch resonators together.

  3. Analysis of the impact of an aircraft crash on underground concrete ducts with protective slab at reactor buildings

    International Nuclear Information System (INIS)

    Kotulla, B.; Hansson, V.

    1977-01-01

    In this paper different types of idealization for a dynamic analysis of underground concrete ducts with protective slab are discussed and compared. Ducts between reactor and control building of a nuclear power plant are to be designed for loadings produced by an aircraft crash. These ducts have a height of about three to four meters and are two to eight meters wide. They are designed with a protective slab about 1.5 m in thickness at ground level and with an intermediate layer of earth of about one meter in thickness. An analysis has to take into account the combined effects of a protective slab with a relatively thin intermediate layer of earth and the underlaying duct and layer of soil with the nonlinear behavior of concrete due to cracking. For describing this behavior two types of idealization were made. One type is a continuum type calculation which describes the slab, the soil and the duct by finite elements. In the other type of idealization a model consisting of springs and lumped masses is used. The protective slab and the intermediate layer of earth may be described as a plate on elastic foundation. The behavior of the cracked part of the plate and the part of earth layer beneath and loads transferred to the uncracked part of the slab and the surrounding soil may be described by parallel springs. Spring and mass of this part of the model have to take into account the cracking of the upper slab which leads to a nonlinear characteristic of the spring. In addition the location of the loading in relation to the duct has to be considered. The duct may be described by a beam on elastic foundation which is loaded locally. From this model representative mass and spring have to be determined

  4. Numeric Wake Equalizing Duct Geometry Optimization for a Given Ship

    Directory of Open Access Journals (Sweden)

    George Martinas

    2015-06-01

    Hence the pressure on designers to achieve both reduced fuel costs and reduced emissions by optimising the hull and propeller has never been higher. In parallel to the performance improvement of new built vessels, there has been great interest in the potential to enhance the performance of existing vessels through retrofit of devices to the hull. In any case for instance the WED device must be customized to fit to the afterbody of the ship in terms of performing its supposed function. The Designer is therefore placed in the front of multiple geometric solutions from between he has to make a choice. This paper is intended to help the Designers to have a rational choosing approach by involving the numeric optimization of the geometry of the WED in order to select the best fitted WED to perform the best in order to achieve some predefined parameters. In this paperwork a given geometry of a WED device is taken and via Design Optimization the geometry of the duct was refined so that better results are achieved with a smaller and more compact WED. In doing so, the Designer is assisted by numeric optimization methods to choose from only three final candidates instead of several thousands in order to provide the best fitted WED geometry for a given ship afterbody.

  5. Oblique bile duct predisposes to the recurrence of bile duct stones.

    Directory of Open Access Journals (Sweden)

    Pavel Strnad

    Full Text Available BACKGROUND AND STUDY AIMS: Bile stones represent a highly prevalent condition and abnormalities of the biliary tree predispose to stone recurrence due to development of biliary stasis. In our study, we assessed the importance of an altered bile duct course for stone formation. PATIENTS AND METHODS: 1,307 patients with choledocholithiasis in the absence of any associated hepatobiliary disease who underwent endoscopic retrograde cholangiopancreatography (ERCP between 2002 and 2009 were analysed. The angle enclosed between the horizontal portion of the common bile duct (CBD and the horizontal plane was measured (angle α. Oblique common bile duct (OCBD was defined as a CBD with angle α < 45°. RESULTS: 103 patients (7.9% were found to harbour OCBD and these were compared to 104 randomly selected control subjects. Compared to controls, OCBD patients were (i significantly older (72 ± 13 vs. 67 ± 13, p<0.00001; (ii more frequently underwent a cholecystectomy (p = 0.02 and biliary surgery (p = 0.003 prior to the diagnosis and (iii more often developed chronic pancreatitis (p = 0.04 as well as biliary fistulae (p = 0.03. Prior to and after ERCP, OCBD subjects displayed significantly elevated cholestatic parameters and angle α negatively correlated with common bile duct diameter (r = -0.29, p = 0.003. OCBD subjects more often required multiple back-to-back ERCP sessions to remove bile stones (p = 0.005 as well as more ERCPs later on due to recurrent stone formation (p<0.05. CONCLUSION: OCBD defines a novel variant of the biliary tree, which is associated with chronic cholestasis, hampers an efficient stone removal and predisposes to recurrence of bile duct stones.

  6. Sustainable architecture approach in designing residential ...

    African Journals Online (AJOL)

    Sustainable architecture has been shaped with vernacular materials based on the vernacular architecture according to climatic conditions, saving energy and responding to needs and social and cultural conditions. In cold region architecture, the buildings are constructed as steps on the hills in the direction of sun and ...

  7. Post-Tensioning Duct Air Pressure Testing Effects on Web Cracking

    Science.gov (United States)

    2015-01-01

    Nevada Department of Transportation (NDOT) post-tensioned concrete bridges have experienced web cracking near the post-tensioning ducts during the construction process. The ducts were air pressure tested to ensure the duct can successfully be grouted...

  8. Morphological study of pancreatic duct in red jungle fowl

    African Journals Online (AJOL)

    Jane

    2010-10-18

    Oct 18, 2010 ... the birds is considered to have four lobes: ventral, dorsal, third and splenic; with three ducts: ventral, dorsal and ... morphology of the pancreatic duct of birds in general and fowl in particular. Therefore, this study .... border of these cells were stained with purple color. (Figure 12). However, after being treated ...

  9. Chloride and potassium conductances of cultured human sweat ducts

    DEFF Research Database (Denmark)

    Novak, I; Pedersen, P S; Larsen, Erik Hviid

    1992-01-01

    The purpose of this study was to characterize the ion conductances, in particular those for Cl- and K+, of human sweat duct cells grown in primary culture. Sweat duct cells from healthy individuals were grown to confluence on a dialysis membrane, which was then mounted in a mini-Ussing chamber an...

  10. Sound waves in two-dimensional ducts with sinusoidal walls

    Science.gov (United States)

    Nayfeh, A. H.

    1974-01-01

    The method of multiple scales is used to analyze the wave propagation in two-dimensional hard-walled ducts with sinusoidal walls. For traveling waves, resonance occurs whenever the wall wavenumber is equal to the difference of the wavenumbers of any two duct acoustic modes. The results show that neither of these resonating modes could occur without strongly generating the other.

  11. Intracellular pH in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I; Hug, M; Greger, R

    1997-01-01

    In order to study the mechanism of H+ and HCO3- transport in a HCO3- secreting epithelium, pancreatic ducts, we have measured the intracellular pH (pHi) in this tissue using the pH sensitive probe BCECF. We found that exposures of ducts to solutions containing acetate/acetic acid or NH4+/NH3 buff...

  12. Seismic assessment of the Pickering pressure relief duct

    International Nuclear Information System (INIS)

    Ghobarah, A.

    1995-05-01

    The objectives of the study are to examine the structural response of the Pickering pressure relief duct when subjected to earthquake ground motion and to estimate the seismic withstand capacity of various components of the structural system on the basis of performance criteria consistent with the safety function of the duct. (author). 24 refs., 16 tabs., 31 figs

  13. 14 CFR 23.1103 - Induction system ducts.

    Science.gov (United States)

    2010-01-01

    ... engine installations, each induction system duct must be— (1) Strong enough to prevent induction system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts. 23.1103 Section 23... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Induction System...

  14. Morphological study of pancreatic duct in red jungle fowl | Kadhim ...

    African Journals Online (AJOL)

    Morphological and histochemical study of the pancreas and pancreatic ducts of ten adult red jungle fowl (Gallus gallus spadiceus) were carried out by means of light microscopy. The bulk of the pancreas consists of a dorsal, ventral, third and small splenic lobe. Three pancreatic ducts were recognized as they join the ...

  15. Long duct nacelle aerodynamic development for DC-10 derivatives

    Science.gov (United States)

    Patel, S. P.; Donelson, J. E.

    1980-01-01

    The results are presented of a wind tunnel test utilizing a 4.7-percent-scale semispan model of the DC-10 in the Calspan 8-foot transonic wind tunnel. The effect of a revised long-duct nacelle shape on the channel velocities, the incremental drag relative to the baseline long-duct nacelle, and channel velocities for the baseline long-duct nacelle were determined and compared with data obtained at Ames. The baseline and the revised long-duct nacelles are representative of a CF6-50 mixed-flow configuration and were evaluated on a model of a proposed DC-10 stretched-fuselage configuration. The results showed that the revised long-duct nacelle has an appreciable effect on the inboard channel velocities, resulting in an increased channel Mach number. However, the pressure recovery on the nacelle afterbody was about the same for both nacelles. The lift curves for both long-duct nacelle configurations were the same. The channel pressures measured at Calspan were in good agreement with those measured at Ames for the baseline long-duct nacelle. The incremental drag for the revised nacelle was measured as two to four counts (three counts is approximately equal to one percent of the airplane drag) higher than that of the baseline long-duct nacelle.

  16. Radiopaque intrahepatic duct stones in plain radiograph: case report

    International Nuclear Information System (INIS)

    Kim, Mi Young; Suh, Chang Hae; Park, Chan Sup; Chung, Won Kyun

    1994-01-01

    We experienced 3 cases of intrahepatic duct stones detected on plain radiographs. The patients had history of multiple episodes of recurrent cholangitis. Radiographic characteristics of these stones included multiple, round or rectangular radiopaque densities surrounded by calcified rim; these densities showed a branching pattern along the intrahepatic ducts

  17. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    Jul 5, 2012 ... Successful management of parotid duct injury depends on early diagnosis and appropriate intervention, failing of ... to diagnose and manage the parotid duct injuries using an “epidural catheter” which is often used for inducing spinal anesthesia. .... Water-soluble contrast media have a definite advantage.

  18. Magnetic resonance imaging of Muellerian duct anomalies in children

    International Nuclear Information System (INIS)

    Li, Yi; Phelps, Andrew; Zapala, Matthew A.; MacKenzie, John D.; MacKenzie, Tippi C.; Courtier, Jesse

    2016-01-01

    Muellerian duct anomalies encompass a wide variety of disorders resulting from abnormalities in the embryological development of the Muellerian ducts. In the prepubertal pediatric population, Muellerian duct anomalies are often incidental findings on studies obtained for other reasons. The onset of menses can prompt more clinical symptoms. Proper characterization of Muellerian duct anomalies is important because these anomalies can affect the development of gynecological disorders as well as fertility. Muellerian duct anomalies also carry a high association with other congenital anomalies, particularly renal abnormalities. MRI is widely considered the best modality for assessing Muellerian duct anomalies; it provides multiplanar capability, clear anatomical detail and tissue characterization without ionizing radiation. MRI allows for careful description of Muellerian duct anomalies, often leading to classification into the most widely accepted classification system for Muellerian duct anomalies. This system, developed by the American Society of Reproductive Medicine, includes seven subtypes: uterine agenesis/hypoplasia, unicornuate, didelphys, bicornuate, septate, arcuate, and diethylstilbestrol (DES) drug-related uterus. In cases of complex anomalies that defy classification, MRI allows detailed depiction of all components of the anatomical abnormality, allowing for proper management and surgical planning. (orig.)

  19. The Consortium of Advanced Residential Buildings (CARB) - A Building America Energy Efficient Housing Partnership

    Energy Technology Data Exchange (ETDEWEB)

    Robb Aldrich; Lois Arena; Dianne Griffiths; Srikanth Puttagunta; David Springer

    2010-12-31

    This final report summarizes the work conducted by the Consortium of Advanced Residential Buildings (CARB) (http://www.carb-swa.com/), one of the 'Building America Energy Efficient Housing Partnership' Industry Teams, for the period January 1, 2008 to December 31, 2010. The Building America Program (BAP) is part of the Department of Energy (DOE), Energy Efficiency and Renewable Energy, Building Technologies Program (BTP). The long term goal of the BAP is to develop cost effective, production ready systems in five major climate zones that will result in zero energy homes (ZEH) that produce as much energy as they use on an annual basis by 2020. CARB is led by Steven Winter Associates, Inc. with Davis Energy Group, Inc. (DEG), MaGrann Associates, and Johnson Research, LLC as team members. In partnership with our numerous builders and industry partners, work was performed in three primary areas - advanced systems research, prototype home development, and technical support for communities of high performance homes. Our advanced systems research work focuses on developing a better understanding of the installed performance of advanced technology systems when integrated in a whole-house scenario. Technology systems researched included: - High-R Wall Assemblies - Non-Ducted Air-Source Heat Pumps - Low-Load HVAC Systems - Solar Thermal Water Heating - Ventilation Systems - Cold-Climate Ground and Air Source Heat Pumps - Hot/Dry Climate Air-to-Water Heat Pump - Condensing Boilers - Evaporative condensers - Water Heating CARB continued to support several prototype home projects in the design and specification phase. These projects are located in all five program climate regions and most are targeting greater than 50% source energy savings over the Building America Benchmark home. CARB provided technical support and developed builder project case studies to be included in near-term Joule Milestone reports for the following community scale projects: - SBER Overlook at

  20. Evaluation of Malaria Infection In Relation to Age and Residential ...

    African Journals Online (AJOL)

    Objective: To investigate malaria infection in relation to age and residential area. Design: A cross sectional study. Setting: Kipsamoite Dispensary of Nandi County in Kenya. Subjects: The demographic details and medical history for all consenting patients was taken by the clinical officer/nurse. Intervention: Clinical ...

  1. Quality Assurance Roadmap for High Performance Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-10-05

    This report outlines the approach to quality assurance in the construction process for new residential construction, including seven process steps from the assessment of current construction practice, through design and documentation changes, to training and quality control for on-site personnel.

  2. Thermal comfort in residential buildings by the millions

    DEFF Research Database (Denmark)

    Østergård, Torben; Maagaard, Steffen; Jensen, Rasmus Lund

    2016-01-01

    In Danish building code and many design briefings, criteria regarding thermal comfort are defined for “critical” rooms in residential buildings. Identifying the critical room is both difficult and time-consuming for large, multistory buildings. To reduce costs and time, such requirement often cau...

  3. Hepatitis B infection in black children from residential care facilities ...

    African Journals Online (AJOL)

    Objectives. A study was undertaken to assess the prevalence of hepatitis B infection in selected residential child care facilmes in Natal. Design. All residents at three facilities in the Durban and. Pietermaritzburg areas of Kwazulu-Natal were tested for markers of hepatitis B infection as part of a broader health.

  4. A review of residential computer oriented energy control systems

    Energy Technology Data Exchange (ETDEWEB)

    North, Greg

    2000-07-01

    The purpose of this report is to bring together as much information on Residential Computer Oriented Energy Control Systems as possible within a single document. This report identifies the main elements of the system and is intended to provide many technical options for the design and implementation of various energy related services.

  5. Architecture and craftsmanship: Residential building "Kaldera", Banjaluka, architect Branislav Stojanovic

    Directory of Open Access Journals (Sweden)

    Marić-Milašinović Dijana

    2003-01-01

    Full Text Available The subjects of analysis were the multi-layered expressions applied by the author in designing the residential building in Banjaluka. These are foremost the site, the location, and the corner motif, as the building’s outstanding formal accents. Next is the analysis of the applied materials their treatment and the accomplished effects. The craftsmanship has been emphasised since it demanded a close cooperation of the architect and the craftsman. Furthermore, the interior organisation of this non-standard residential building has been elucidated.

  6. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching.......Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...

  7. Emergency lighting for industrial, commercial and residential premises

    CERN Document Server

    Lyons, X

    2013-01-01

    Emergency Lighting: For Industrial, Commercial and Residential Premises concerns itself with the provision of emergency lighting to facilitate exit routes for people in industrial, commercial, and residential areas. The book covers important topics such as the objectives of emergency lighting systems; the identification of safe routes under low lighting in different areas; and related devices such as luminaires, emergency signs, and way-guidance. Also discussed are the applications of emergency lighting; factors to consider in the design of emergency lighting; electrical installations; and tes

  8. Prediction of turbulent gas-solids flow in curved ducts using the Eulerian-Lagrangian method

    Science.gov (United States)

    Naik, S.; Bryden, I. G.

    1999-10-01

    The flow of particulate two-phase flow mixtures occur in several components of solid fuel combustion systems, such as the pressurised fluidised bed combustors (PFBC) and suspension-fired coal boilers. A detailed understanding of the mixture characteristics in the conveying component can aid in refining and optimising its design. In this study, the flow of an isothermal, dilute two-phase particulate mixture has been examined in a high curvature duct, which can be representative of that transporting the gas-solid mixture from the hot clean-up section to the gas turbine combustor in a PFBC plant. The numerical study has been approached by utilising the Eulerian-Lagrangian methodology for describing the characteristics of the fluid and particulate phases. By assuming that the mixture is dilute and the particles are spherical, the governing particle momentum equations have been solved with appropriately prescribed boundary conditions. Turbulence effects on the particle dispersion were represented by a statistical model that accounts for both the turbulent eddy lifetime and the particle transit time scales. For the turbulent flow condition examined it was observed that mixtures with small particle diameters had low interphase slip velocities and low impaction probability with the pipe walls. Increasing the particle diameters (>50 m) resulted in higher interphase slip velocities and, as expected, their impaction probability with the pipe walls was significantly increased. The particle dispersion is significant for the smaller sizes, whereas the larger particles are relatively insensitive to the gas turbulence. The main particle impaction region, and locations most prone to erosion damage, is estimated to be within an outer duct length of two to six times the duct diameter, when the duct radius of curvature to the duct diameter ratio is equal to unity. Copyright

  9. Topological mixing study of non-Newtonian duct flows

    Science.gov (United States)

    Speetjens, Michel; Metcalfe, Guy; Rudman, Murray

    2006-10-01

    Tracer advection of non-Newtonian fluids in reoriented duct flows is investigated in terms of coherent structures in the web of tracer paths that determine transport properties geometrically. Reoriented duct flows are an idealization of in-line mixers, encompassing many micro and industrial continuous mixers. The topology of the tracer dynamics of reoriented duct flows is Hamiltonian. As the stretching per reorientation increases from zero, we show that the qualitative route from the integrable state to global chaos and good mixing does not depend on fluid rheology. This is due to a universal symmetry of reoriented duct flows, which we derive, controlling the topology of the tracer web. Symmetry determines where in parameter space global chaos first occurs, while increasing non-Newtonian effects delays the quantitative value of onset. Theory is demonstrated computationally for a representative duct flow, the rotated arc mixing flow.

  10. Cystic duct remnant mucocele in a liver transplant recipient

    International Nuclear Information System (INIS)

    Ahlawat, Sushil K.; Fishbien, Thomas M.; Haddad, Nadim G.

    2008-01-01

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  11. Cystic duct remnant mucocele in a liver transplant recipient

    Energy Technology Data Exchange (ETDEWEB)

    Ahlawat, Sushil K. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); University of Medicine and Dentistry of New Jersey, New Jersey Medical School, Newark, NJ (United States); Fishbien, Thomas M. [Georgetown University Hospital, Department of Medicine, Division of Gastroenterology, Washington, DC (United States); Haddad, Nadim G. [Georgetown University Hospital, Department of Surgery, Division of Transplant Surgery, Washington, DC (United States)

    2008-08-15

    Cystic duct remnant mucocele is an extremely rare complication of liver transplantation in children. Surgical correction is usually required for cystic duct remnant mucocele when it causes biliary obstruction. We describe a 14-month-old liver transplant recipient who presented with biliary obstruction 1 month after orthotopic liver transplantation with an end-to-end choledochocholedocal biliary anastomosis for hepatoblastoma. US, CT and cholangiography findings were consistent with mucocele of the allograft cystic duct remnant. Surgery was not needed in our patient because the mucocele and biliary obstruction had resolved on repeat imaging most likely due to guidewire manipulation during cholangiography, resulting in opening of the cystic duct remnant orifice and drainage into the common duct. (orig.)

  12. Transhepatic cholangiography in patients with nondilated bile ducts

    International Nuclear Information System (INIS)

    Teplick, S.K.; Flick, P.; Brandon, J.C.; Haskin, P.H.; Goldstein, R.C.; Brennan, C.

    1988-01-01

    Transhepatic cholangiography was performed in 90 patients with suspected biliary tract disease and nondilated ducts. A21- or 22-gauge needle was used, and the number of passes were not limited. The bile ducts were visualized in 62 of 90 patients, and the study was diagnostic in 58 of 90. In 13 patients, the ducts were not adequately opacified, and in one, a left hepatic duct stone was missed. Seventeen of 62 cholangiograms were abnormal (eight strictures, six calculi three cases of poor emptying); eight of the 17 patients underwent percutaneous transhepatic biliary drainage. Twenty-one of 90 patients had complications. Two deaths resulted from sepsis and hemorrhage. Sixteen of 90 patients had significant abdominal pain lasting several hours to several days. One patient had bile peritonitis, and one each developed increasing pancreatitis and transient bacteremia. The authors conclude that transhepatic cholangiography should not be the initial invasive procedure of choice in patients with nondilated ducts

  13. Winglet and long duct nacelle aerodynamic development for DC-10 derivatives

    Science.gov (United States)

    Taylor, A. B.

    1978-01-01

    Advanced technology for application to the Douglas DC-10 transport is discussed. Results of wind tunnel tests indicate that the winglet offers substantial cruise drag reduction with less wing root bending moment penalty than a wing-tip extension of the same effectiveness and that the long duct nacelle offers substantial drag reduction potential as a result of aerodynamic and propulsion improvements. The aerodynamic design and test of the nacelle and pylon installation are described.

  14. FIELD EVALUATION OF IMPROVED METHODS FOR MEASURING THE AIR LEAKAGE OF DUCT SYSTEMS UNDER NORMAL OPERATING CONDITIONS IN 51 HOMES

    Energy Technology Data Exchange (ETDEWEB)

    Paul W. Francisco; Larry Palmiter; Erin Kruse; Bob Davis

    2003-10-18

    Duct leakage in forced-air distribution systems has been recognized for years as a major source of energy losses in residential buildings. Unfortunately, the distribution of leakage across homes is far from uniform, and measuring duct leakage under normal operating conditions has proven to be difficult. Recently, two new methods for estimating duct leakage at normal operating conditions have been devised. These are called the nulling test and the Delta-Q test. Small exploratory studies have been done to evaluate these tests, but previously no large-scale study on a broad variety of homes has been performed to determine the accuracy of these new methods in the field against an independent benchmark of leakage. This sort of study is important because it is difficult in a laboratory setting to replicate the range of leakage types found in real homes. This report presents the results of a study on 51 homes to evaluate these new methods relative to an independent benchmark and a method that is currently used. An evaluation of the benchmark procedure found that it worked very well for supply-side leakage measurements, but not as well on the return side. The nulling test was found to perform well, as long as wind effects were minimal. Unfortunately, the time and difficulty of setup can be prohibitive, and it is likely that this method will not be practical for general use by contractors except in homes with no return ducts. The Delta-Q test was found to have a bias resulting in overprediction of the leakage, which qualitatively confirms the results of previous laboratory, simulation, and small-scale field studies. On average the bias was only a few percent of the air handler flow, but in about 20% of the homes the bias was large. A primary flaw with the Delta-Q test is the assumption that the pressure between the ducts and the house remain constant during the test, as this assumption does not hold true. Various modifications to the Delta-Q method were evaluated as

  15. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  16. Trends of Sustainable Residential Architecture

    OpenAIRE

    Narvydas, A

    2014-01-01

    The article is based on Master’s research conducted during Scottish Housing Expo 2010. The aim of the research was to determine the prevailing trends in sustainable residential architecture. Each trend can be described by features detected during visual and technical observation of project data. Based on that architects may predict possible problems related to a specific trend.

  17. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  18. Congestion and residential moving behaviour

    DEFF Research Database (Denmark)

    Larsen, Morten Marott; Pilegaard, Ninette; Van Ommeren, Jos

    2008-01-01

    we study how congestion and residential moving behaviour are interrelated, using a two-region job search model. Workers choose between interregional commuting and residential moving, in order to live closer to their place of work. This choice affects the external costs of commuting, due to conges......we study how congestion and residential moving behaviour are interrelated, using a two-region job search model. Workers choose between interregional commuting and residential moving, in order to live closer to their place of work. This choice affects the external costs of commuting, due...... to congestion. We focus on the equilibrium in which some workers currently living in one region accept jobs in the other, with a fraction of them choosing to commute from their current residence to the new job in the other region and the remainder choosing to move to the region in which the new job is located....... The welfare-maximising road tax is derived, which is essentially the Pigouvian tax, given the absence of a tax on moving. Given the presence of moving taxes, which are substantial in Europe, the optimal road tax for commuters is the Pigouvian tax plus the amortised value of the moving tax, evaluated...

  19. Convergence of Residential Gateway Technology

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Balm, M.; Jong, C.M. de; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  20. Energy Performance of Three Residential College Buildings in University of Malaya Campus, Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Adi Ainurzaman Jamaludin

    2011-12-01

    Full Text Available Three residential colleges located in Kuala Lumpur, Malaysia, were selected for energy performance analysis in regards to its implementation of bioclimatic design strategies. Specifically, passive design strategies on daylighting and natural ventilation were examined. In Malaysia, the residential college or hostel is a multi-residential building providing accommodation to university students. The three residential colleges in this study, namely C1, C2 and C3, were built in different years with different designs and forms, particularly with regards to enclosure and facade design, solar control devices, passive daylight concepts, and natural ventilation strategies. The building designs were carefully studied and an electric consumption analysis was carried out in each residential college. This study revealed that the wide-scale implementation of bioclimatic design strategies in college C2 help reduced the annual energy consumption. The building bioclimatic design features that are accountable to reduce energy consumption are the internal courtyard and balconies on each unit of floor area, as shown in C3.Results from this study highly recommend internal courtyard and balcony building combination for multi residential building design, especially in tropical urban regions.

  1. Common bile duct pathologies at nawabshah

    International Nuclear Information System (INIS)

    Talpur, A.A.; Memon, J.M.; Ansari, A.G.

    2007-01-01

    To determine the causes, presentation, management and outcome of Common Bile Duct (CBD) pathologies. All patients who presented with CBD pathologies. Data of all the patients with CBD pathologies was collected and entered on a proforma, including their complaints, positive examination findings, investigations, diagnosis, procedure performed and its outcome. During the study period 45 patients presented with CBD pathology. Amongst them 14 were males and the rest females (31), with a mean age of 36.7 years. Around 67% patients had choledocholithiasis as the commonest cause. Exploration of the CBD with T-tube insertion was the commonest procedure, performed in 69% patients. About 4% patients had retained stones and 20% developed wound infection. Mean hospital stay was 13 days. Most common pathology involving the CBD was secondary stones; 95% patients had associated gall stones also. (author)

  2. Granular Cell Tumour of the Bile Duct in Association with Intrahepatic Bile Duct Adenomas

    OpenAIRE

    Schweiger, F; Radhi, J; Coop, FW; Murphy, RW

    1994-01-01

    Granular cell tumour of the extrahepatic biliary tract is a rare benign lesion likely of neurogenic origin. Review of the previously reported cases indicates that almost all patients are female, and the majority is Black. Symptoms usually are those of biliary obstruction or cholecystitis. Surgical resection of the tumour is curative. Intrahepatic bile duct adenoma is another rare benign biliary neoplasm that does not manifest clinically but can be confused with metastatic carcinoma, cholangio...

  3. Transcatheter stenting of arterial duct in duct-dependent congenital heart disease

    Directory of Open Access Journals (Sweden)

    Đukić Milan

    2013-01-01

    Full Text Available Introduction. Critical congenital heart diseases (CHD are mostly duct-dependent and require stable systemic-pulmonary communication. In order to maintain patency of the ductus arteriosus (DA, the first line treatment is Prostaglandin E1 and the second step is the surgical creation of aortic-pulmonary shunt. To reduce surgical risk in neonates with the critical CHD, transcatheter stenting of DA can be performed in selected cases. Case Outline. A four-month old infant was diagnosed with the pulmonary artery atresia with ventricular septal defect (PAA/VSD. The left pulmonary artery was perfused from DA, and the right lung through three major aortopulmonary collaterals (MAPCAs. A coronary stent was placed in the long and critically stenotic DA, with final arterial duct diameter of 3.5 mm, and significantly increased blood supply to the left lung. After the procedure, the infant’s status was improved with regard to arterial oxygen saturation, feeding and weight gain. During the follow-up, one year later, aortography revealed in-stent stenosis. The left pulmonary artery, as well as the branches, was well-developed and the decision was made to proceed with further surgical correction. Conclusion. Stenting of DA can be an effective alternative to primary surgical correction in selected patients with duct-dependent CHD.

  4. 7 CFR 2902.17 - Plastic insulating foam for residential and commercial construction.

    Science.gov (United States)

    2010-01-01

    ... Protection Agency designated building insulation containing recovered materials as items for which Federal... building insulation products in the Recovered Materials Advisory Notice (RMAN) published for these products... provide a sealed thermal barrier for residential or commercial construction applications. (b) Minimum...

  5. A Near-Hover Adaptive Attitude Control Strategy of a Ducted Fan Micro Aerial Vehicle with Actuator Dynamics

    Directory of Open Access Journals (Sweden)

    Shouzhao Sheng

    2015-09-01

    Full Text Available The aerodynamic parameters of ducted fan micro aerial vehicles (MAVs are difficult and expensive to precisely measure and are, therefore, not available in most cases. Furthermore, the actuator dynamics with risks of potentially destabilizing the overall system are important but often neglected consideration factors in the control system design of ducted fan MAVs. This paper presents a near-hover adaptive attitude control strategy of a prototype ducted fan MAV with actuator dynamics and without any prior information about the behavior of the MAV. The proposed strategy consists of an online parameter estimation algorithm and an adaptive gain scheduling algorithm, with the former accommodating parametric uncertainties, and the latter approximately eliminating the coupling among axes and guaranteeing the control quality of the MAV. The effectiveness of the proposed strategy is verified numerically and experimentally.

  6. Treatment of infants with congenital nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Zhuo Chen

    2014-07-01

    Full Text Available AIM: To explore the different ages of congenital nasolacrimal duct obstruction in infants, take different treatment methods at different times. METHODS:The 87 cases of 102 children were divided into three different age groups: the first group of 25d-3mo of age 21 cases 26 eyes; The second group >3mo-7mo 31 cases 36 eyes; The third group >7-24mo of age 35 cases 40 eyes. For the first group of infants, the implementation of the lacrimal sac nasolacrimal duct massage + eye drops; for the second group of infants, carry lacrimal pressure washing treatment; for the third group of infants, the implementation of the nasolacrimal duct probing treatment. RESULTS:The first group of children through the nasolacrimal duct sac massage + drops tobramycin eye drops treatment unobstructed 12, the cure rate was 46.2%; The second group of children through pressurized irrigation treatment lacrimal patency by 33, the cure rate was 91.7%; The third group of children through the nasolacrimal duct probing unobstructed 36 treatment, the cure rate was 90.0%. The second and third group were better than the first group(χ2=15.71, Pχ2=15.27, Pχ2=0.02, P>0.05.CONCLUSION:Infants with congenital nasolacrimal duct obstruction should distinguish between ages, taking different treatments, in order to obtain a better therapeutic effect, and lacrimal pressure washing is the preferred way of treating infants with congenital nasolacrimal duct obstruction.

  7. New Whole-House Solutions Case Study: Compact Buried Ducts in a Hot-Humid Climate House

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-18

    With U.S. Department of Energy Building America Program support, Home Innovation Research Labs partnered with K. Hovnanian Homes to demonstrate a new buried-duct design that is durable, energy efficient, and cost-effective in a hot-humid climate.

  8. Micro-CHP systems for residential applications

    International Nuclear Information System (INIS)

    Paepe, Michel de; D'Herdt, Peter; Mertens, David

    2006-01-01

    Micro-CHP systems are now emerging on the market. In this paper, a thorough analysis is made of the operational parameters of 3 types of micro-CHP systems for residential use. Two types of houses (detached and terraced) are compared with a two storey apartment. For each building type, the energy demands for electricity and heat are dynamically determined. Using these load profiles, several CHP systems are designed for each building type. Data were obtained for two commercially available gas engines, two Stirling engines and a fuel cell. Using a dynamic simulation, including start up times, these five system types are compared to the separate energy system of a natural gas boiler and buying electricity from the grid. All CHP systems, if well sized, result in a reduction of primary energy use, though different technologies have very different impacts. Gas engines seem to have the best performance. The economic analysis shows that fuel cells are still too expensive and that even the gas engines only have a small internal rate of return (<5%), and this only occurs in favourable economic circumstances. It can, therefore, be concluded that although the different technologies are technically mature, installation costs should at least be reduced by 50% before CHP systems become interesting for residential use. Condensing gas boilers, now very popular in new homes, prove to be economically more interesting and also have a modest effect on primary energy consumption

  9. Residential fuel choice in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.D.; Englin, J.E.; Harkreader, S.A.

    1989-02-01

    In 1983, the Northwest Power Planning Council (Council) issued Model Conservation Standards (MCS) designed to improve the efficiency of electrically heated buildings. Since then, the standards have been adopted by numerous local governments and utilities. The Bonneville Power Administration (Bonneville) has played an active role in marketing residential energy efficiency improvements through the Super Good Cents Program (SGCP) and encouraging the adoption and implementation of the MCS as local codes through the Early Adopter Program (EAP). Since the inception of the MCS, however, questions have arisen about the effect of the code and programs on the selection of heating fuels for new homes. Recently, Bonneville has proposed a gradual reduction in the incentive levels under these two programs prior to 1995 based on several assumptions about the market for MCS homes: builder costs will decline as builders gain experience building them; buyers will seek out MCS homes as their appreciation for their lower energy costs and greater comfort increases; and the resale market will increasingly reflect the greater quality of MCS homes. The growing availability of data from several jurisdictions where the MCS have been implemented has recently made it possible to begin assessing the effect of the MCS programs on residential fuel choice and evaluating assumptions underlying the programs and Bonneville's plans to revise them. This study is the first such assessment conducted for Bonneville.

  10. Data on European non-residential buildings.

    Science.gov (United States)

    D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo

    2017-10-01

    This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.

  11. BACTERIOLOGICAL INVESTIGATION ON Fasciola hepatica AND CATTLE BILIARY DUCTS

    Directory of Open Access Journals (Sweden)

    A. Panebianco

    2009-03-01

    Full Text Available The aim of this work was to investigate the occurrence of bacteria in Fasciola hepatica and into cattle biliary ducts containing the parasite. A total of 24 liver and 58 F. hepatica samples were analysed. In all biliary ducts and in 62,06% of parasite Enterobacteriaceae were isolated. The bacterial specie more frequently isolated from parasite were Citrobacter freundii (34%, Proteus mirabilis (18%, Providencia rettgeri (12%, Staphylococcus spp. (18%, Enterobacter spp. (12%. There doesn’t appear to be a correlation between bacterial specie from parasite and ducts. The Authors conclude with some related inspective consideration.

  12. Effects of explosion-generated shock waves in ducts

    International Nuclear Information System (INIS)

    Busby, M.R.; Kahn, J.E.; Belk, J.P.

    1976-01-01

    An explosion in a space causes an increase in temperature and pressure. To quantify the challenge that will be presented to essential components in a ventilation system, it is necessary to analyze the dynamics of a shock wave generated by an explosion, with attention directed to the propagation of such a wave in a duct. Using the equations of unsteady flow and shock tube theory, a theoretical model has been formulated to provide flow properties behind moving shock waves that have interacted with various changes in duct geometry. Empirical equations have been derived to calculate air pressure, temperature, Mach number, and velocity in a duct following an explosion

  13. A remote joint system for large vacuum ducts

    International Nuclear Information System (INIS)

    Hagmann, D.B.; Coughlan, J.B.

    1983-01-01

    A large remote vacuum duct joining system has been developed for fusion machines that uses several two-jaw screwdriven clamps. The preferred location for clamp installation is inside the vacuum duct where access space is available for the actuating device. It also decreases space needed for handling operations exterior to the duct. The clamp system is unique in that it is low cost, applies force directly over the seal, permits leak testing to the seal annulus, is highly reliable, can be remotely replaced, and is usable on a variety of other applications

  14. Experimental and simulation studies on a single pass, double duct solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Forson, F.K. [Kwame Nkrumah Univ. of Science and Technology, Dept. of Mechanical Engineering, Kumasi (Ghana); Rajakaruna, H. [De Montfort Univ., School of Engineering and Technology, Leicester (United Kingdom)

    2003-05-01

    A mathematical model of a single pass, double duct solar air heater (SPDDSAH) is described. The model provides a design tool capable of predicting: incident solar radiation, heat transfer coefficients, mean air flow rates, mean air temperature and relative humidity at the exit. Results from the simulation are presented and compared with experimental ones obtained on a full scale air heater and a small scale laboratory one. Reasonable agreement between the predicted and measured values is demonstrated. Predicted results from a parametric study are also presented. It is shown that significant improvement in the SPDDSAH performance can be obtained with an appropriate choice of the collector parameters and the top to bottom channel depth ratio of the two ducts. The air mass flow rate is shown to be the dominant factor in determining the overall efficiency of the heater. (Author)

  15. Propulsion/airframe interference for ducted propfan engines with ground effect

    Science.gov (United States)

    Arabshahi, Abdollah; Pankajakshan, Ramesh

    1994-01-01

    The advanced propfan propulsion systems design of the next-generation subsonic transport aircraft has been of interest to many airline companies in the past several years. This is due to the studies which indicate that an efficient ducted propfan engine technology offers a significant reduction in aircraft fuel consumption. However, because of the geometric complexity of the configuration, one challenge is the integration of the ducted propfan engine with the airframe so that aerodynamic interference effects frequently encountered near the nacelle can be minimized, or perhaps, optimized. To understand this interaction phenomenon better, it is desirable to have a reliable and efficient computational tool that can predict propeller effects on the flowfield around complex configurations.

  16. Morphology of the testes and epididymal ducts in the pampas cat Leopardus colocolo (Molina, 1782

    Directory of Open Access Journals (Sweden)

    Mahmoud Mehanna

    Full Text Available ABSTRACT: The pampas cat Leopardus colocolo (Molina, 1782 is a species of the Felidae family, widely distributed in South America, included on CITES Appendix II and classified as Near Threatened on the IUCN Red List, with population trend decreasing. Based on this information, the objective of this study is to describe morphologically the testes and epididymal ducts of pampas cat. The animal, coming from the Federal University of Mato Grosso Zoo, Brazil, had died after anesthesia procedure and the male reproductive system was dissected to collect the testicles. The samples taken were fragmented and histologically examined. From the microscopic analysis of the testes were identified: vaginal and tunica albuginea, formed by dense connective tissue modeled with large amount of collagen fibers. The tunica albuginea fibrous septa emits into the body. The seminiferous tubules are coiled and coated internally by spermatogenic epithelium consisting of Sertoli cells, surrounded by a basement membrane in the presence of myoid cells. The interstitial tissue between the seminiferous tubules, is composed of loose connective tissue, blood and lymph vessels, and Leydig cells in polyhedral shape. The epididymal ducts showed pseudostratified columnar epithelium with secretory cells of which stereocilia design, situated on a basement membrane filled by myoid cells. This epithelium has principal and basal cells, the main cell design stereocilia toward the lumen of the epididymal duct.

  17. Empirically Derived Strength of Residential Roof Structures for Solar Installations.

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, Stephen F.; Sanchez, Alfred; Campos, Ivan A.; Gerstle, Walter H.

    2014-12-01

    Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

  18. Aerosol sampling from stacks and ducts at the Rocky Flats Plant

    International Nuclear Information System (INIS)

    McFarlane, A.R.; Anand, N.K.; Ortiz, C.A.

    1995-01-01

    While the Rocky Flats Plant (RFP) in Golden, CO is being decommissioned; there is air flow through the ventilation systems in the buildings. Although the air is HEPA filtered, under the requirements of both the U.S. EPA and the U.S. DOE, several of the stacks and ducts must be continuously monitored for radionuclide aerosol particles, where plutonium is the principal radionuclide of concern. The air sampling effort for compliance with EPA requirements is focussed on the acquisition of representative aerosol samples, which are collected on filters and subsequently analyzed in a laboratory. The goal of the DOE sampling is to acquire representative samples that can be analyzed with near-real-time monitors for alarming purposes, where the alarms are used to warn workers that may be affected by elevated concentrations of radionuclides. The air sampling at RFP is based on single point representative sampling with a shrouded probe. For stacks and ducts that are under the cognizance of EPA, the approach is embodied in a set of Alternate Reference Methodologies that EPA has approved for use at DOE facilities. Shrouded probes were designed based on numerical predictions of performance and the efficacy of the probes was verified by wind tunnel tests. Aerosol transport lines were designed using a code, DEPOSITION that provides optimization of aerosol penetration. Adequacy of a location for single point sampling was based on numerical criteria for mixing of both contaminant mass and fluid momentum as manifested by the uniformity of the velocity profile and the profiles of tracer gas and aerosol particles. Scale models were constructed of key ducts and these were tested in the laboratory to determine the proper locations. For ducts and stacks that fall under DOE, but not EPA requirements, similar methodology was used; however, the single point sampling location is based on alarming considerations

  19. The transmission of thermal neutrons along air filled ducts in water

    International Nuclear Information System (INIS)

    Piercey, D.C.

    1962-06-01

    Predictions and measurements of thermal neutron transmission along air filled ducts in water have been made. To aid the analysis, the ducts were shielded in various ways using cadmium sheet. The predictions were, in general, in agreement to better than a factor 4 for ducts up to 200 duct radii in length. (author)

  20. Radiation of sound in a semi-infinite hard duct inserted axially into a larger infinite lined duct

    Science.gov (United States)

    Tiwana, Mazhar Hussain; Nawaz, Rab; Mann, Amer Bilal

    2017-12-01

    This article examines sound radiation from a hard semi-infinite duct placed symmetrically inside an acoustically lined duct. We introduce a wake on right handed region of the duct configuration to analyze sound radiation process for the trailing edge situation. The integral transforms together with Wiener-Hopf techniques render the solution of underlying problem. However expressions for field intensity involve infinite sums/products that enable solution using truncation approach. The sound radiation analysis is then observed graphically while using different choice of some pertinent parameters. It is worth mentioning that results of leading edge situation can be recovered as a limiting case.

  1. Aerodynamic performance of 0.4066-scale model of JT8D refan stage with S-duct inlet

    Science.gov (United States)

    Moore, R. D.; Kovich, G.; Lewis, G. W., Jr.

    1977-01-01

    A scale model of the JT8D refan stage was tested with a scale model of the S-duct inlet design for the refanned Boeing 727 center engine. Detailed survey data of pressures, temperatures, and flow angles were obtained over a range of flows at speeds from 70 to 97 percent of design speed. Two S-duct configurations were tested; one with a bellmouth inlet and the other with a flight lip inlet. The results indicated that the overall performance was essentially unaffected by the distortion generated by the S-duct inlet. The stall weight flow increased by less than 0.5 kg/sec (approximately 1.5% of design flow) with the S-duct inlet compared with that obtained with uniform flow. The detailed measurements indicated that the inlet guide vane (IGV) significantly reduced circumferential variations. For example, the flow angles ahead of the IGV were positive in the right half of the inlet and negative in the left half. Behind the IGV, the flow angles tended to be more uniform circumferentially.

  2. Residential greenness and adiposity: Findings from the UK Biobank.

    Science.gov (United States)

    Sarkar, Chinmoy

    2017-09-01

    With the rapid urbanization and prevailing obesity pandemic, the role of residential green exposures in obesity prevention has gained renewed focus. The study investigated the effects of residential green exposures on adiposity using a large and diverse population sample drawn from the UK Biobank. This was a population based cross-sectional study of 333,183 participants aged 38-73years with individual-level data on residential greenness and built environment exposures. Residential greenness was assessed through 0.50-metre resolution normalized difference vegetation index (NDVI) derived from spectral reflectance measurements in remotely sensed colour infrared data and measured around geocoded participants' dwelling. A series of continuous and binary outcome models examined the associations between residential greenness and markers of adiposity, expressed as body-mass index (BMI) in kg/m 2 , waist circumference (WC) in cm, whole body fat (WBF) in kg and obesity (BMI≥30kg/m 2 ) after adjusting for other activity-influencing built environment and individual-level confounders. Sensitivity analyses involved studying effect modification by gender, age, urbanicity and SES as well as examining relationships between residential greenness and active travel behaviour. Residential greenness was independently and consistently associated with lower adiposity, the association being robust to adjustments. An interquartile increment in NDVI greenness was associated with lower BMI (β BMI =-0.123kg/m 2 , 95% CI: -0.14, -0.10kg/m 2 ), WC (β WC =-0.551cm, 95% CI: -0.61, -0.50cm), and WBF (β WBF =-0.138kg, 95% CI: -0.18, -0.10kg) as well as a reduced relative risk of obesity (RR=0.968, 95% CI: 0.96, 0.98). Residential greenness was beneficially related with active travel, being associated with higher odds of using active mode for non-work travel (OR=1.093, 95% CI: 1.08, 1.11) as well as doing >30min walking (OR=1.039, 95% CI: 1.03, 1.05). Residing in greener areas was associated

  3. Method and apparatus for duct sealing using a clog-resistant insertable injector

    Science.gov (United States)

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  4. Noise generation by ducted combustion systems. [resonant oscillations

    Science.gov (United States)

    Chiu, H. H.; Plett, E. G.; Summerfield, M.

    1973-01-01

    Analysis of the interaction between a zone of nonsteady combustion and its confining duct shows that resonant type oscillations occur with resulting noise intensities far greater than from corresponding unconfined flame zones. The blading action on the flow through the compressor and turbine of an engine generates discrete frequency noise which, it is found, is enhanced by the response of the combustion zone in between. Ducted combustor experiments verify the predicted resonant type noise, the amplitude and frequency of which are strongly influenced by the duct dimensions and end impedance. A convergent exit nozzle results in stronger internal resonant noise oscillations but also generates a higher jet velocity, with the attendant jet noise which exceeds noise from inside the duct at jet Mach numbers near unity.-

  5. Lacrimal gland duct stones: misdiagnosed as chalazion in 3 cases.

    Science.gov (United States)

    Kim, Sung Chul; Lee, Kook; Lee, Sang Un

    2014-02-01

    To report 3 cases of lacrimal gland duct stones misdiagnosed as chalazion. Retrospective case series. Three patients with lacrimal gland duct stones misdiagnosed as chalazion at a local clinic between 2010 and 2012. A thorough review of clinical, imaging, and histopathologic manifestations. Clinical manifestations of lacrimal gland duct stones included conjunctival injection, lid swelling, tenderness, and ocular discharge, which are similar to chalazion symptoms. Computed tomography revealed a relatively well-defined, high-density mass near the lacrimal gland. Histopathologic examination of excised material revealed calcified amorphous stones. Intractable chalazion-like lesions at the lateral canthal area near the lacrimal gland should be carefully examined; imaging studies are required to confirm the presence of lacrimal gland duct stones, which require surgical removal. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  6. Surgical versus endoscopic treatment of bile duct stones

    DEFF Research Database (Denmark)

    Martin, D J; Vernon, D R; Toouli, J

    2006-01-01

    10% to 18% of patients undergoing cholecystectomy for gallstones have common bile duct (CBD) stones. Treatment options for these stones include pre- or post-operative endoscopic retrograde cholangiopancreatography (ERCP) or open or laparoscopic surgery....

  7. Status of the development of hot gas ducts for HTRs

    International Nuclear Information System (INIS)

    Stehle, H.; Klas, E.

    1984-01-01

    In the PNP nuclear process heat system the heat generated in the helium cooled core is transferred to the steam reformer and to the successive steam generator or to the intermediate heat exchanger by the primary helium via suitable hot gas ducts. The heat is carried over to the steam gasifier by the intermediate heat exchanger and a secondary helium loop. In both the primary and the secondary loop, the hot gas ducts are internally insulated by a ceramic fibre insulation to protect the support tube and the pressure housing from the high helium temperatures. A graphite hot gas liner will be used for the coaxial primary duct with an annular gap between support tube and pressure shell for the cold gas counterflow. A metallic hot gas liner will be installed in the secondary duct

  8. Transverse testicular ectopia with persistent Mullerian duct syndrome

    African Journals Online (AJOL)

    mail: amingoh@gmail.com. Received 30 September 2011 accepted 12 February 2012. Introduction. Transverse testicular ectopia (TTE) associated with persistent Mullerian duct syndrome (PMDS) is a rare anomaly that can be encountered ...

  9. Sound transmission through ducts and aircraft noise prediction, volume 1

    Science.gov (United States)

    Schauer, J. J.; Datko, J. T.; Guyton, R. W.

    1982-01-01

    Aircraft engine acoustical lining impedance models, ray acoustics, hydrodynamic modes, and transient analysis of sound propagation in variable area duct studies were applied to aircraft noise prediction. The effects of several duct lining configurations in a TF33 P5 and a CFM56 engined KC-135B aircraft were predicted. The prediction was based on a model corrected to fit flight noise data and modified by including theoretical duct noise attenuation predictions. The transient solution of variable area ducts permitted the prediction of sound propgation in bullet nose inlets for no low and was moderately successful when a potential flow was included with low Mach numbers. Volume 1 contains the technical report and analysis. Volume 2 contains the user's manuals and listings of the computer codes developed.

  10. Measure Guideline: Buried and/or Encapsulated Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Zoeller, W. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Mantha, P. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license.

  11. Surgical management of Stenson's duct injury using epidural catheter

    African Journals Online (AJOL)

    2012-07-05

    rediffmail.com. Introduction. Deep penetrating wounds over the buccal area are common in maxillofacial injuries. Vital structures like parotid duct, facial nerve branches, and transverse facial artery are vulnerable to injury in ...

  12. Residential mobility and childhood leukemia.

    Science.gov (United States)

    Amoon, A T; Oksuzyan, S; Crespi, C M; Arah, O A; Cockburn, M; Vergara, X; Kheifets, L

    2018-07-01

    Studies of environmental exposures and childhood leukemia studies do not usually account for residential mobility. Yet, in addition to being a potential risk factor, mobility can induce selection bias, confounding, or measurement error in such studies. Using data collected for California Powerline Study (CAPS), we attempt to disentangle the effect of mobility. We analyzed data from a population-based case-control study of childhood leukemia using cases who were born in California and diagnosed between 1988 and 2008 and birth certificate controls. We used stratified logistic regression, case-only analysis, and propensity-score adjustments to assess predictors of residential mobility between birth and diagnosis, and account for potential confounding due to residential mobility. Children who moved tended to be older, lived in housing other than single-family homes, had younger mothers and fewer siblings, and were of lower socioeconomic status. Odds ratios for leukemia among non-movers living mobility, including dwelling type, increased odds ratios for leukemia to 2.61 (95% CI: 1.76-3.86) for living mobility of childhood leukemia cases varied by several sociodemographic characteristics, but not by the distance to the nearest power line or calculated magnetic fields. Mobility appears to be an unlikely explanation for the associations observed between power lines exposure and childhood leukemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. RESIDENTIAL MORTGAGE IN MODERN RUSSIA

    Directory of Open Access Journals (Sweden)

    Dementiev N. P.

    2015-03-01

    Full Text Available The article presents a comparative analysis of residential mortgages in Russia and the United States. The primary ways of mortgage refinancing are outlined. Predominance of the elements of two-level refinancing system of residential mortgage in Russia and the United States is shown. The activity of the Agency for Housing Mortgage Lending (AHML, the basic tool of the Russian government’s mortgage policy, is described in detail. In its objectives and functions the AHML is similar to the American mortgage agencies Ginnie Mae, Fannie Mae and Freddie Mac. Similarities were identified in the Russian and US residential mortgages in the pre-crisis period (high rates of mortgage growth, favourable economic conjuncture, low interest rates, large increase in house prices, speculative housing demand. During the mortgage crisis, the policies of the Russian and US governments and monetary authorities had also much in common (monetary policy easing, cheap central banks loans, extended facilities of mortgage refinancing on the part of state agencies, mortgage rescue scheme, social mortgage programs. But the scope of mortgage in Russia is enormously narrow as compared to the US mortgage. The most important reason for that - low incomes of the Russian population.

  14. Flame acceleration and transition to detonation in ducts

    Energy Technology Data Exchange (ETDEWEB)

    Ciccarelli, G. [Queen' s University, 130 Stuart Street, Kingston, Ontario (Canada); Dorofeev, S. [FM Global, 1151 Boston-Providence Turnpike, P.O. Box 910, Norwood, MA 02062 (United States)

    2008-08-15

    This paper reviews the state of knowledge on flame acceleration and deflagration-to-detonation transition (DDT) in smooth ducts and ducts equipped with turbulence-producing obstacles. The objective is to bring to light the basic understanding of the phenomenon and its application to explosion safety. The scope of the review is restricted to homogeneous gas-phase combustion with emphasis placed on experimental investigation. (author)

  15. Molecular basis of potassium channels in pancreatic duct epithelial cells

    DEFF Research Database (Denmark)

    Hayashi, M.; Novak, Ivana

    2013-01-01

    Potassium channels regulate excitability, epithelial ion transport, proliferation, and apoptosis. In pancreatic ducts, K channels hyperpolarize the membrane potential and provide the driving force for anion secretion. This review focuses on the molecular candidates of functional K channels...... other cell types, preferably in epithelia, and, where known, their identification and functions in pancreatic ducts and in adenocarcinoma cells. We conclude by pointing out some outstanding questions and future directions in pancreatic K channel research with respect to the physiology of secretion...

  16. Bile Duct Obstruction Secondary to Chronic Pancreatitis in Seven Dogs

    OpenAIRE

    Cribb, Alastair E.; Burgener, David C.; Reimann, Keith A.

    1988-01-01

    Seven icteric dogs were determined to have bile duct obstruction secondary to chronic pancreatitis. All dogs had histories of intermittent vomiting and diarrhea. Alkaline phosphatase and alanine aminotransferase activities and total bilirubin concentrations were markedly elevated. Diagnosis was based on exploratory laparotomy and histological examination. Each dog had a 3 to 10 cm mass in the body of the pancreas and obstruction of the common bile duct. Three dogs treated with pancreatectomy,...

  17. Ecological aspects of fan-assisted balanced ventilation systems in the residential area - a practical investigation with recommendations for design and installation; Oekologische Aspekte der Komfortlueftungen im Wohnbereich - Eine praxisnahe Untersuchung mit Hinweisen zu Planung und Bau von Wohnungslueftungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Primas, A. [Basler und Hofmann Ingenieure und Planer AG, Zuerich (Switzerland)

    2004-07-01

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the environmental impact of fan-assisted balanced ventilation systems on the basis of a life-cycle analysis. The influence of various components and their operating parameters on the systems is compared. The results, which were calculated using the Eco-indicator 99 and the 'ecoinvent' data-base, are presented and commented on. Six variants for a six-apartment house with varying air-throughput and using various materials for the ducting are analysed. The results of the analysis are presented in tabular and graphical form and discussed in detail.

  18. WAVE PROPAGATION in the HOT DUCT of VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Richard Schultz; Jim C. P. Liou

    2013-07-01

    In VHTR, helium from the reactor vessel is conveyed to a power conversion unit through a hot duct. In a hypothesized Depressurized Conduction Cooldown event where a rupture of the hot duct occurs, pressure waves will be initiated and reverberate in the hot duct. A numerical model is developed to quantify the transients and the helium mass flux through the rupture for such events. The flow path of the helium forms a closed loop but only the hot duct is modeled in this study. The lower plum of the reactor vessel and the steam generator are treated as specified pressure and/or temperature boundary to the hot duct. The model is based on the conservation principles of mass, momentum and energy, and on the equations of state for helium. The numerical solution is based on the method of characteristics with specified time intervals with a predictor and corrector algorithm. The rupture sub-model gives reasonable results. Transients induced by ruptures with break area equaling 20%, 10%, and 5% of the duct cross-sectional area are described.

  19. Amblyopia risk factors in infants with congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Kim, Jung Wan; Lee, Hwa; Chang, Minwook; Park, Minsoo; Lee, Tae Soo; Baek, Sehyun

    2013-07-01

    This study aims to report the prevalence of amblyopia risk factors in patients with congenital nasolacrimal duct obstructions. We recruited patients who were treated for congenital nasolacrimal duct obstruction from April 2007 to December 2011 at Korea University Ansan Hospital. We evaluated visual acuity and refraction, performed strabismus test and slit-lamp examination, and assessed marginal reflex distance 1 (MRD1) to rule out amblyopia risk factors. We examined 26 children among 115 patients. Ten patients underwent probing procedure and 16 underwent Monoka stent intubation. Nine (35%) patients showed amblyopia risk factors, which occurred in the same eye as the congenital nasolacrimal duct obstruction in 8 (89%) patients. Seven out of 9 patients had refractive error alone, and 2 patients had both refractive error and strabismus. One (11%) had anisometropia, 2 (22%) had hyperopia, and 8 (89%) had astigmatism. Children with congenital nasolacrimal duct obstruction had a higher prevalence of amblyopia risk factors than children in the general population. Children with congenital nasolacrimal duct obstruction require special attention and treatments for refractive error. We recommend early treatment, such as probing or intubation, for congenital nasolacrimal duct obstruction.

  20. Role of Collecting Duct Renin in the Pathogenesis of Hypertension.

    Science.gov (United States)

    Gonzalez, Alexis A; Lara, Lucienne S; Prieto, Minolfa C

    2017-08-01

    The presence of renin production by the principal cells of the collecting duct has opened new perspectives for the regulation of intrarenal angiotensin II (Ang II). Angiotensinogen (AGT) and angiotensin-converting enzyme (ACE) are present in the tubular fluid coming from the proximal tubule and collecting duct. All the components needed for Ang II formation are present along the nephron, and much is known about the mechanisms regulating renin in juxtaglomerular cells (JG); however, those in the collecting duct remain unclear. Ang II suppresses renin via protein kinase C (PKC) and calcium (Ca 2+ ) in JG cells, but in the principal cells, Ang II increases renin synthesis and release through a pathophysiological mechanism that increases further intratubular Ang II de novo formation to enhance distal Na + reabsorption. Transgenic mice overexpressing renin in the collecting duct demonstrate the role of collecting duct renin in the development of hypertension. The story became even more interesting after the discovery of a specific receptor for renin and prorenin: the prorenin receptor ((P)RR), which enhances renin activity and fully activates prorenin. The interactions between (P)RR and prorenin/renin may further increase intratubular Ang II levels. In addition to Ang II, other mechanisms have been described in the regulation of renin in the collecting duct, including vasopressin (AVP), bradykinin (BK), and prostaglandins. Current active investigations are aimed at elucidating the mechanisms regulating renin in the distal nephron segments and understand its role in the pathogenesis of hypertension.

  1. Measure Guideline: Buried and/or Encapsulated Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. This Building America Measure Guideline synthesizes previously published research on BEDs and provides practical information to builders, contractors, homeowners, policy analysts, building professions, and building scientists. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license. Persons implementing duct system improvements should not go beyond their expertise or qualifications. This guideline provides valuable information for a building industry that has struggled to address ductwork thermal losses in new and existing homes. As building codes strengthen requirements for duct air sealing and insulation, flexibility is needed to address energy efficiency goals. While ductwork in conditioned spaces has been promoted as the panacea for addressing ductwork thermal losses, BEDs installations approach - and sometimes exceed - the performance of ductwork in conditioned spaces.

  2. Parotid duct laceration repair in two horses : case report

    Directory of Open Access Journals (Sweden)

    A. Olivier

    1998-07-01

    Full Text Available Repair of parotid duct lacerations in 2 horses is described using intraluminal silastic tubing as a stent. The duct was lacerated traumatically at the facial vessel notch (incisura vasorum facialium in the 1st horse, and iatrogenically after removal of an intraluminal sialolith after development of infection within the duct in the 2nd horse. In both cases, a silastic tube was passed retrograde into the duct via the salivary papilla, past the wound until the end lay rostroventral to the parotid salivary gland. The severed salivary ducts and the wounds were sutured. The external portion of the silastic tube was sutured to the skin and the tube left in place. Recovery in the 1st case was uneventful. In the 2nd case a salivary duct/cutaneous fistula formed at a wound distant from the sutured wound, which healed spontaneously. This technique differs from a similar described technique in that the stent tube exits the oral cavity and is attached to the outer skin surface.

  3. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Beal, D. [BA-PIRC, Cocoa, FL (United States); McIlvaine, J. [BA-PIRC, Cocoa, FL (United States); Fonorow, K. [BA-PIRC, Cocoa, FL (United States); Martin, E. [BA-PIRC, Cocoa, FL (United States)

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces.

  4. High-speed Tests of a Ducted Body with Various Air-outlet Openings

    Science.gov (United States)

    Becker, John V.; Baals, Donald D.

    1942-01-01

    Test of a ducted body with Internal flow were made in the 8-foot high-speed wind tunnel for the purpose of studying the effects on external drag and an critical speed of the addition of efficient inlet and outlet openings to a basic streamline shape. Drag tests of a 13.6- inch-diameter streamline body of fineness ratio 6.14 were made at Mach numbers ranging from 0.20 to 0.75. The model was centrally mounted on a 9-percent-thick airfoil and was designed to have an efficient airfoil-body juncture and a high critical speed. An air inlet at the nose and various outlets at the tail were added: drag and internal-flow data were obtained over the given speed range. The critical speed of the ducted bodies was found to be as high as that of the streamline body. The external - drag with air flow through the body did not exceed the drag of the basic streamline shape. No appreciable variation in the efficiency of the diffuser section of the internal duct occurred throughout the Mach number range of the tests.

  5. Heat transfer in laminar flow of non-Newtonian fluids in ducts of elliptical section

    Energy Technology Data Exchange (ETDEWEB)

    Maia, Cassio Roberto Macedo; Aparecido, Joao Batista [Department of Mechanical Engineering, College of Engineering of Ilha Solteira, Sao Paulo State University Unesp, 15385-000, Ilha Solteira, SP (Brazil); Milanez, Luiz Fernando [Department of Energy, College of Mechanical Engineering, Campinas State University Unicamp, 13081-970, Campinas, SP (Brazil)

    2006-11-15

    Laminar forced convection inside tubes of various cross-section shapes is of interest in the design of a low Reynolds number heat exchanger apparatus. Heat transfer to thermally developing, hydrodynamically developed forced convection inside tubes of simple geometries such as a circular tube, parallel plate, or annular duct has been well studied in the literature and documented in various books, but for elliptical duct there are not much work done. The main assumption used in this work is a laminar flow of a power flow inside elliptical tube, under a boundary condition of first kind with constant physical properties and negligible axial heat diffusion (high Peclet number). To solve the thermally developing problem, we use the generalized integral transform technique (GITT), also known as Sturm-Liouville transform. Actually, such an integral transform is a generalization of the finite Fourier transform where the sine and cosine functions are replaced by more general sets of orthogonal functions. The axes are algebraically transformed from the Cartesian coordinate system to the elliptical coordinate system in order to avoid the irregular shape of the elliptical duct wall. The GITT is then applied to transform and solve the problem and to obtain the once unknown temperature field. Afterward, it is possible to compute and present the quantities of practical interest, such as the bulk fluid temperature, the local Nusselt number and the average Nusselt number for various cross-section aspect ratios. (author)

  6. Jagged2a-notch signaling mediates cell fate choice in the zebrafish pronephric duct.

    Directory of Open Access Journals (Sweden)

    Ming Ma

    2007-01-01

    Full Text Available Pronephros, a developmental model for adult mammalian kidneys (metanephros and a functional kidney in early teleosts, consists of glomerulus, tubule, and duct. These structural and functional elements are responsible for different kidney functions, e.g., blood filtration, waste extraction, salt recovery, and water balance. During pronephros organogenesis, cell differentiation is a key step in generating different cell types in specific locations to accomplish designated functions. However, it is poorly understood what molecules regulate the differentiation of different cell types in different parts of the kidney. Two types of epithelial cells, multi-cilia cells and principal cells, are found in the epithelia of the zebrafish distal pronephric duct. While the former is characterized by at least 15 apically localized cilia and expresses centrin2 and rfx2, the latter is characterized by a single primary cilium and sodium pumps. Multi-cilia cells and principal cells differentiate from 17.5 hours post-fertilization onwards in a mosaic pattern. Jagged2a-Notch1a/Notch3-Her9 is responsible for specification and patterning of these two cell types through a lateral inhibition mechanism. Furthermore, multi-cilia cell hyperplasia was observed in mind bomb mutants and Mind bomb was shown to interact with Jagged2a and facilitate its internalization. Taken together, our findings add a new paradigm of Notch signaling in kidney development, namely, that Jagged2a-Notch signaling modulates cell fate choice in a nephric segment, the distal pronephric duct.

  7. Buoyancy effects in vertical rectangular duct with coplanar magnetic field and single sided heat load

    Science.gov (United States)

    Kostichev, P. I.; Poddubnyi, I. I.; Razuvanov, N. G.

    2017-11-01

    In some DEMO blanket designs liquid metal flows in vertical ducts of rectangular cross-section between ceramic breeder units providing their cooling. Heat exchange in these conditions is governed by the influence of magnetic field (coplanar) and by buoyancy effects that depend on the flow orientation to the gravity vector (downward and upward flow). Magnetohydrodynamic and heat transfer of liquid metal in vertical rectangular ducts is not well researched. Experimental study of buoyancy effects in rectangular duct with coplanar magnetic field for one-sided heat load and downward and upward flowsis presented in this paper. The detail research with has been done on mercury MHD close loop with using of the probe technique allow to discover several advantageous and disadvantageous effects. The intensive impact of buoyancy force has been observed in a few regime of downward flow which has been laminarized by magnetic field. Due to the development in the flow of the secondary large-scale vortices heat transfer improved and the temperature fluctuations of the abnormally high intensity have been fixed. On the contrary, in the upward flow the buoyancy force stabilized the flow which lead to decreasing of the turbulence heat transfer ratio and, consequently, deterioration of heat transfer.

  8. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  9. Mathematical modeling to predict residential solid waste generation.

    Science.gov (United States)

    Benítez, Sara Ojeda; Lozano-Olvera, Gabriela; Morelos, Raúl Adalberto; Vega, Carolina Armijo de

    2008-01-01

    One of the challenges faced by waste management authorities is determining the amount of waste generated by households in order to establish waste management systems, as well as trying to charge rates compatible with the principle applied worldwide, and design a fair payment system for households according to the amount of residential solid waste (RSW) they generate. The goal of this research work was to establish mathematical models that correlate the generation of RSW per capita to the following variables: education, income per household, and number of residents. This work was based on data from a study on generation, quantification and composition of residential waste in a Mexican city in three stages. In order to define prediction models, five variables were identified and included in the model. For each waste sampling stage a different mathematical model was developed, in order to find the model that showed the best linear relation to predict residential solid waste generation. Later on, models to explore the combination of included variables and select those which showed a higher R(2) were established. The tests applied were normality, multicolinearity and heteroskedasticity. Another model, formulated with four variables, was generated and the Durban-Watson test was applied to it. Finally, a general mathematical model is proposed to predict residential waste generation, which accounts for 51% of the total.

  10. Generation of gamma-ray streaming kernels through cylindrical ducts via Monte Carlo method

    International Nuclear Information System (INIS)

    Kim, Dong Su

    1992-02-01

    Since radiation streaming through penetrations is often the critical consideration in protection against exposure of personnel in a nuclear facility, it has been of great concern in radiation shielding design and analysis. Several methods have been developed and applied to the analysis of the radiation streaming in the past such as ray analysis method, single scattering method, albedo method, and Monte Carlo method. But they may be used for order-of-magnitude calculations and where sufficient margin is available, except for the Monte Carlo method which is accurate but requires a lot of computing time. This study developed a Monte Carlo method and constructed a data library of solutions using the Monte Carlo method for radiation streaming through a straight cylindrical duct in concrete walls of a broad, mono-directional, monoenergetic gamma-ray beam of unit intensity. The solution named as plane streaming kernel is the average dose rate at duct outlet and was evaluated for 20 source energies from 0 to 10 MeV, 36 source incident angles from 0 to 70 degrees, 5 duct radii from 10 to 30 cm, and 16 wall thicknesses from 0 to 100 cm. It was demonstrated that average dose rate due to an isotropic point source at arbitrary positions can be well approximated using the plane streaming kernel with acceptable error. Thus, the library of the plane streaming kernels can be used for the accurate and efficient analysis of radiation streaming through a straight cylindrical duct in concrete walls due to arbitrary distributions of gamma-ray sources

  11. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    International Nuclear Information System (INIS)

    Zhou Aiqing; Gao Wei; Yu Zhiqing; Li Feng; Wang Rongfa

    2003-01-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 ± 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 ± 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 ± 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated

  12. Thermally developing forced convection on non-Newtonian fluids inside elliptical ducts

    Energy Technology Data Exchange (ETDEWEB)

    Maia, Cassio; Aparecido, Joao [Sao Paulo State Univ., Dept. of Mechanical Engineering, Ilha Solteira, SP (Brazil); Milanez, Luiz [State Univ. of Campinas, Dept. of Mechanical Engineering, Campinas, SP (Brazil)

    2004-07-01

    Laminar-forced convection inside tubes of various cross-section shapes is of interest in the design of a low Reynolds number heat exchanger apparatus. Heat transfer to thermally developing, hydrodynamically developed forced convection inside tubes of simple geometries such as a circular tube, parallel plate, or annular duct has been well studied in the literature and documented in various books, but for elliptical duct there are not much work done. The main assumptions used in this work are a non-Newtonian fluid, laminar flow, constant physical properties, and negligible axial heat diffusion (high Peclet number). Most of the previous research in elliptical ducts deal mainly with aspects of fully developed laminar flow forced convection, such as velocity profile, maximum velocity, pressure drop, and heat transfer quantities. In this work, we examine heat transfer in a hydrodynamically developed, thermally developing laminar forced convection flow of fluid inside an elliptical tube under a second kind of a boundary condition. To solve the thermally developing problem, we use the generalized integral transform technique (GITT), also known as Sturm-Liouville transform. Actually, such an integral transform is a generalization of the finite Fourier transform, where the sine and cosine functions are replaced by more general sets of orthogonal functions. The axes are algebraically transformed from the Cartesian coordinate system to the elliptical coordinate system in order to avoid the irregular shape of the elliptical duct wall. The GITT is then applied to transform and solve the problem and to obtain the once unknown temperature field. Afterward, it is possible to compute and present the quantities of practical interest, such as the bulk fluid temperature, the local Nusselt number, and the average Nusselt number for various cross-section aspect ratios. (Author)

  13. Residential care : Dutch and Italian residents of residential care facilities compared

    NARCIS (Netherlands)

    de Heer-Wunderink, Charlotte; Caro-Nienhuis, Annemarie D.; Sytema, Sjoerd; Wiersma, Durk

    2008-01-01

    Aims - Characteristics of patients living in residential care facilities and the availability of mental hospital- and residential beds in Italy and The Netherlands were compared to assess whether differences in the process of deinstitutionalisation have influenced the composition of their

  14. Human Thermal Comfort In Residential House Buildings Of Jimma Town Southwest Ethiopia.

    Directory of Open Access Journals (Sweden)

    Chali Yadeta

    2015-08-01

    Full Text Available Indoor human thermal comfort is an important factor in indoor air quality assessment. Thermal comfort affects human health work efficiency and overall wellbeing. Thermal discomfort in indoors lowers the emotional and physical health of the occupants. This paper targets to explore human thermal comfort in residential house buildings of Jimma town and state some possible mechanisms to improve the existing thermal discomfort in large number the houses. For the study 303 structured questionnaires were distributed to the residential houses in thirteen places of the town based on predetermined criteria. The study reveals that human thermal discomfort in residential houses Jimma town are mainly from poor architectural design and improper use of heat generating appliances in indoors. The uses architectural design that suites the present climatic conditions and use of materials that facilitates ventilations will enhance the realization of the required human thermal comfort in residential houses of the study area.

  15. Ejaculatory duct obstruction in infertile men.

    Science.gov (United States)

    Paick, J; Kim, S H; Kim, S W

    2000-04-01

    To analyse our experience of ejaculatory duct obstruction (EDO) in infertile men, evaluating the diagnostic steps and the outcome of management according to the aetiology. Over a 7-year period, 50 infertile men were diagnosed with EDO as a contributory factor to male infertility. Diagnostic criteria included a history, physical examination, semen analyses, semen fructose measurement, hormonal study, testicular biopsy, transrectal ultrasonography (TRUS) and/or vasography. Thirty-one patients with EDO were treated by transurethral resection (26) or forced lavage via a vasotomy (five). In 45 of the 50 men, semen analyses showed the typical characteristics of complete EDO. Seminal values were variable in five cases of partial EDO; the semen fructose levels were EDO was a midline cyst in 16, Wolffian malformation in four, tuberculosis in 17, previous genitourinary infection in five and idiopathic in eight men. In 17 patients the seminal vesicles appeared to be atrophied on TRUS; 15 of these patients had a history of pulmonary tuberculosis and subsequent vasography in five showed multiple bilateral vasal obstruction. TRUS findings correlated well with vasography except in one case. The overall rate of improved semen values and paternity was 61% and 26%, respectively. Of 16 patients with midline cysts, 14 had improved semen variables and achieved paternity, seven after transurethral resection. TRUS should be the first diagnostic procedure used when infertile men are suspected of having EDO, but vasography should still be considered for a more comprehensive diagnosis. In patients with atrophic seminal vesicles on TRUS and with a history of pulmonary tuberculosis, further study is unnecessary and microscopic epididymal sperm aspiration is recommended for in vitro fertilization. The measurement of semen fructose may be helpful in diagnosing partial EDO. Patients with midline cysts who are treated by transurethral resection are expected to have the best outcome.

  16. Molecular characterization of apocrine salivary duct carcinoma.

    Science.gov (United States)

    Chiosea, Simion I; Williams, Lindsay; Griffith, Christopher C; Thompson, Lester D R; Weinreb, Ilan; Bauman, Julie E; Luvison, Alyssa; Roy, Somak; Seethala, Raja R; Nikiforova, Marina N

    2015-06-01

    Contemporary classification and treatment of salivary duct carcinoma (SDC) require its thorough molecular characterization. Thirty apocrine SDCs were analyzed by the Ion Ampliseq Cancer HotSpot panel v2 for mutations in 50 cancer-related genes. Mutational findings were corroborated by immunohistochemistry (eg, TP53, BRAF, β-catenin, estrogen, and androgen receptors) or Sanger sequencing/SNaPshot polymerase chain reaction. ERBB2 (HER2), PTEN, FGFR1, CDKN2A/P16, CMET, EGFR, MDM2, and PIK3CA copy number changes were studied by fluorescence in situ hybridization. TP53 mutations (15/27, 56%), PTEN loss (11/29, 38%, including 2 cases with PTEN mutation), PIK3CA hotspot mutations (10/30, 33%), HRAS hotspot mutations (10/29; 34%), and ERBB2 amplification (9/29, 31%, including 1 case with mutation) represented the 5 most common abnormalities. There was no correlation between genetic changes and clinicopathologic parameters. There was substantial overlap between genetic changes: 8 of 9 cases with ERBB2 amplification also harbored a PIK3CA, HRAS, and TP53 mutation and/or PTEN loss. Six of 10 cases with PIK3CA mutation also had an HRAS mutation. These findings provide a molecular rationale for dual targeting of mitogen-activated protein kinase and phosphoinositide 3-kinase pathways in SDC. FGFR1 amplification (3/29, 10%) represents a new potential target. On the basis of studies of breast carcinomas, the efficacy of anti-ERBB2 therapy will likely be decreased in SDC with ERBB2 amplification co-occurring with PIK3CA mutation or PTEN loss. Therefore, isolated ERBB2 testing is insufficient for theranostic stratification of apocrine SDC. On the basis of the prevalence and type of genetic changes, apocrine SDC appears to resemble one subtype of breast carcinoma-"luminal androgen receptor positive/molecular apocrine."

  17. Technology change and energy consumption: A comparison of residential subdivisions

    Science.gov (United States)

    Nieves, L. A.; Nieves, A. L.

    The energy savings in residential buildings likely to result from implementation of the building energy performance standards (BEPS) were assessed. The goals were to: compare energy use in new homes designed to meet or exceed BEPS levels of energy efficiency with that in similar but older homes designed to meet conventional building codes, and to survey the home owners regarding their energy conservation attitudes and behaviors and to ascertain the degree to which conservation attitudes and behaviors are related to residential energy use. The consumer demand theory which provides the framework for the empirical analysis is presented. The sample residences are described and the data collection method discussed. The definition and measurement of major variables are presented.

  18. Selection and Exergy Analysis of Fuel Cell System to Meet all Energy Needs of Residential Buildings

    OpenAIRE

    G.R. Ashari; N.Hedayat; S. Shalbaf; E.Hajidavalloo

    2011-01-01

    In this paper a polymer electrolyte membrane (PEM) fuel cell power system including burner, steam reformer, heat exchanger and water heater has been considered to meet the electrical, heating, cooling and domestic hot water loads of residential building which in Tehran. The system uses natural gas as fuel and works in CHP mode. Design and operating conditions of a PEM fuel cell system is considered in this study. The energy requirements of residential building and the num...

  19. Chapter 17: Residential Behavior Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, James [Cadmus Group, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral social sciences to influence household energy use. Strategies may include providing households with real-time or delayed feedback about their energy use; supplying energy-efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5%.

  20. External built residential environment characteristics that affect mental health of adults.

    Science.gov (United States)

    Ochodo, Charles; Ndetei, D M; Moturi, W N; Otieno, J O

    2014-10-01

    External built residential environment characteristics include aspects of building design such as types of walls, doors and windows, green spaces, density of houses per unit area, and waste disposal facilities. Neighborhoods that are characterized by poor quality external built environment can contribute to psychosocial stress and increase the likelihood of mental health disorders. This study investigated the relationship between characteristics of external built residential environment and mental health disorders in selected residences of Nakuru Municipality, Kenya. External built residential environment characteristics were investigated for 544 residents living in different residential areas that were categorized by their socioeconomic status. Medically validated interview schedules were used to determine mental health of residents in the respective neighborhoods. The relationship between characteristics of the external built residential environment and mental health of residents was determined by multivariable logistic regression analyses and chi-square tests. The results show that walling materials used on buildings, density of dwelling units, state of street lighting, types of doors, states of roofs, and states of windows are some built external residential environment characteristics that affect mental health of adult males and females. Urban residential areas that are characterized by poor quality external built environment substantially expose the population to daily stressors and inconveniences that increase the likelihood of developing mental health disorders.

  1. Shear strength in corner region of reinforced concrete duct type structures to be embedded in soil

    International Nuclear Information System (INIS)

    Aoyagi, Y.; Endo, T.

    1993-01-01

    Reinforced concrete ducts for accommodating emergency cooling water pipes are generally embedded in soil. The structures is classified as one of the most important structures in terms of earthquake resistant design. During a strong earthquake it is subjected to shear deformations in concerted movement with surrounding soil. The comer regions of the duct should be designed against shear with moment combined. However, the complicated stress conditions in the region render the design more intricate in comparison with the case of simple determinate RC beam type structures. With the above situation in mind an experimental study was conducted, in which prototype as well as one half scale models representing the stress conditions in the region of interest were loaded and brought to failure in shear. The cross section of the prototype test model without shear reinforcements was 60 (height) x 30cm (width), and the tensile reinforcement ratio was 2.58%. The following results were obtained within the limit of the experimental study. (1) The shear capacity predicted by Japanese Design Code for linear RC members over-estimated the experimental ones with a considerably large safety margin of 4.4-5.0. (2) An improved design procedure to be applied to the specific structure was proposed, which gave a reasonable safety factor against shear failure of 1.7-2.0. (3) Combined smeared and discrete cracking model was utilized to simulate the shear failure mechanism, which could realistically pursue experimental behaviors. (author)

  2. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  3. Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures

    International Nuclear Information System (INIS)

    Joudi, Khalid A.; Al-Amir, Qusay R.

    2014-01-01

    Highlights: • R290, R407C and R410A in residential split A/C units at high ambient. • 1 and 2 TR residential air conditioners with R22 alternatives at high ambient. • Residential split unit performance at ambients up to 55 °C with R22 alternatives. - Abstract: Steady state performance of residential air conditioning systems using R22 and alternatives R290, R407C, R410A, at high ambient temperatures, have been investigated experimentally. System performance parameters such as optimum refrigerant charge, coefficient of performance, cooling capacity, power consumption, pressure ratio, power per ton of refrigeration and TEWI environmental factor have been determined. All refrigerants were tested in the cooling mode operation under high ambient air temperatures, up to 55 °C, to determine their suitability. Two split type air conditioner of 1 and 2 TR capacities were used. A psychrometric test facility was constructed consisting of a conditioned cool compartment and an environmental duct serving the condenser. Air inside the conditioned compartment was maintained at 25 °C dry bulb and 19 °C wet bulb for all tests. In the environmental duct, the ambient air temperature was varied from 35 °C to 55 °C in 5 °C increments. The study showed that R290 is the better candidate to replace R22 under high ambient air temperatures. It has lower TEWI values and a better coefficient of performance than the other refrigerants tested. It is suitable as a drop-in refrigerant. R407C has the closest performance to R22, followed by R410A

  4. Does salivary duct repositioning prevent complications after tumor resection or salivary gland surgery?

    Science.gov (United States)

    Sakakibara, Akiko; Minamikawa, Tsutomu; Hashikawa, Kazunobu; Sakakibara, Shunsuke; Hasegawa, Takumi; Akashi, Masaya; Furudoi, Shungo; Komori, Takahide

    2015-05-01

    Tissue that is resected for the treatment of oral tumors often includes salivary gland ducts. At their institution, the authors conserve and transfer as much of the salivary duct as possible during these procedures to avoid obstructive complications. Differentiating these obstructive complications from a metastatic node can be challenging and can confound subsequent oncologic management. This study compared and examined the effectiveness of salivary duct repositioning in decreasing the incidence of obstructive complications. Cases of oromandibular disease treated with salivary duct resection at Kobe University Graduate School of Medicine from 2008 to 2013 were retrospectively analyzed. Thirty-two cases (25 patients) of Wharton duct resection and 31 cases (31 patients) of Stensen duct resection were included. The incidence of complications after salivary duct repositioning, duct ligation, and retention of the sublingual gland around the Wharton duct was compared. Wharton ducts were repositioned in 30 cases and ligated in 2 cases. Complications, including oral swelling at the Wharton duct, were observed in 5 cases of repositioning and 2 cases of ligation. Stensen ducts were repositioned in 9 cases and ligated in 22 cases. The only complication reported was a single case of salivary fistula after ligation. Salivary duct repositioning is performed to prevent blockage of physiologic salivary discharge. Complications were more frequently associated with Wharton ducts than with Stensen ducts because of the unique physiologic and anatomic characteristics of the Wharton duct. Repositioning of the salivary duct is a suitable method for preventing complications associated with the Wharton duct. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Clearance of refractory bile duct stones with extracorporeal shockwave lithotripsy.

    Science.gov (United States)

    Ellis, R D; Jenkins, A P; Thompson, R P; Ede, R J

    2000-11-01

    Extracorporeal shockwave lithotripsy (ESWL) has been used since the mid-1980s to fragment bile duct stones which cannot be removed endoscopically. Early machines required general anaesthesia and immersion in a waterbath. To investigate the effectiveness of the third generation Storz Modulith SL20 lithotriptor in fragmenting bile duct stones that could not be cleared by mechanical lithotripsy. Eighty three patients with retained bile duct stones were treated. All patients received intravenous benzodiazepine sedation and pethidine analgesia. Stones were targeted by fluoroscopy following injection of contrast via a nasobiliary drain or T tube. Residual fragments were cleared at endoscopic retrograde cholangiopancreatography. Complete stone clearance was achieved in 69 (83%) patients and in 18 of 24 patients (75%) who required more than one ESWL treatment. Stone clearance was achieved in all nine patients (100%) with intrahepatic stones and also in nine patients (100%) referred following surgical exploration of the bile duct. Complications included six cases of cholangitis and one perinephric haematoma which resolved spontaneously. Using the Storz Modulith, 83% of refractory bile duct calculi were cleared with a low rate of complications. These results confirm that ESWL is an excellent alternative to surgery in those patients in whom endoscopic techniques have failed.

  6. Modal analysis of an ECC duct for APR+ reactor barrel

    International Nuclear Information System (INIS)

    Kang, H.S.; Lee, K.H.; Kwon, T.S.

    2011-01-01

    Advanced Power Reactor Plus (APR+) provides four Direct Vessel Injection (DVI) ducts on the reactor barrel to enhance the performance of Emergency Core Cooling System (ECCS). Several studies on safety analysis have verified the excellent performance of the DVI duct. In this study, from the viewpoint of mechanical integrity, modal analyses of two full-scaled DVI ducts have been presented; both numerical analysis and modal tests have been performed in air and water. It was found that the numerical simulation and modal test coincide with each other. The DVI duct is a thin shell of 5 mm thickness, so that harmonic responses to RCP blade passing frequencies should be checked. The dominant passing frequencies are known to be 20, 40, 60, 120 and 240 Hz. In addition, an interesting thing in this study is that added mass effect by coolant seems to be so significant that the natural frequency of the ducts under water could be considerably low as compared with those in air; the natural frequency under water is 60 % lower than that in air. (author)

  7. Abnormalities of intrahepatic bile ducts in extrahepatic biliary atresia.

    Science.gov (United States)

    Raweily, E A; Gibson, A A; Burt, A D

    1990-12-01

    The infantile cholangiopathies are a group of conditions associated with neonatal jaundice, which include extrahepatic biliary atresia, paucity of intra-hepatic bile ducts and disorders associated with persistence of fetal biliary structures, the so-called ductal plate malformations. Although previously regarded as distinct entities, it has recently been suggested that they may represent parts of a disease spectrum in which the principal process is one of bile duct destruction, the morphological manifestations in individual cases being influenced by the stage of intra-uterine development at which such injury occurs and by the site within the biliary system at which there is maximum damage. To further examine this concept, we have studied liver biopsy specimens from 37 neonates with extrahepatic biliary atresia, with particular reference to abnormalities of the intrahepatic bile ducts. Paucity of intrahepatic ducts, defined as a bile duct: portal tract ratio of less than 0.9, was identified in six cases (16.2%). In eight cases (21.6%) we found concentric tubular ductal structures similar to those observed in ductal plate malformations. In one case, both abnormalities could be demonstrated. Our findings support the concept that there is overlap between the various types of infantile cholangiopathy.

  8. Prevalence of amblyopia risk factors in congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Matta, Noelle S; Singman, Eric L; Silbert, David I

    2010-10-01

    To determine whether children who present to an ophthalmology practice for nasolacrimal duct obstruction are more likely to have risk factors for amblyopia. A retrospective chart review was conducted on all patients presenting to a pediatric oculoplastic specialist between January 1, 2001, and August 8, 2009. The review yielded 402 pediatric patients diagnosed with nasolacrimal duct obstruction. Children were classified as having amblyopia risk factors on the basis of the American Association for Pediatric Ophthalmology and Strabismus referral criteria. Of 402 patients with nasolacrimal duct obstruction, 100% received a cyclopegic refraction. Of these, 88 patients (22%) were found to have amblyogenic risk factors; 65 of these patients had amblyogenic refractive errors, 9 had strabismus, and 14 had a combination of the two. Of the 88 patients with amblyopia risk factors, 11% had a family history of strabismus compared with 9% of patients without amblyopia risk factors, which was not a statistically significant difference. There was no other significant pathology found on the dilated fundus examinations except for one child known to have persistent hyperplastic primary vitreous and a congenital cataract and one child with previously known CHARGE syndrome before the examination for nasolacrimal duct obstruction. Children who present with nasolacromal duct obstructions seem to be more likely to have amblyopia risk factors and therefore should have a full comprehensive pediatric ophthalmological examination, including cycloplegic refraction. Copyright © 2010 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  9. Percutaneous lithotripsy for removing difficult bile duct stones using endoscopy

    International Nuclear Information System (INIS)

    Kim, See Hyung; Sohn, Chul Ho; Kim, Young Hwan

    2008-01-01

    To describe efficacy of percutaneous lithotripsy for removing difficult bile duct stones using endoscopy. A total of 88 patients with difficulties for the removal of bile duct stones using endoscopy (an impacted stone, stone size > 15 mm, intrahepatic duct (IHD) stone, stone size to bile duct diameter ratio > 1.0), were enrolled in this study. A 12 Fr sheath was inserted through the percutaneous transhepatic biliary drainage (PTBD) tract, and then nitrol stone baskets and a 0.035' snare wire were used to capture, fragment and remove the stones. The technical and clinical success rates were analyzed, together with an analysis of any complications. The overall technical success rate of stone removal was achieved in 79 of 88 patients (89.8%). In five of nine patients with failed stone removal, small residual IHD stones were noted on a cholangiogram. Even if stone removal failed in these cases, cholangitic symptoms were improved and the drainage catheter was successfully removed. Therefore, clinical success was achieved in 84 of 88 patients (95.5%). There were no significant procedure-related complications, except for sepsis in one case. Billiary stone removal using the stone basket and guide-wire snare technique through the PTBD tract is a safe and effective procedure that can be used as a primary method in patients with difficulties for the removal of bile duct stones using endoscopy

  10. Thermal comfort in residential buildings by the millions

    DEFF Research Database (Denmark)

    Østergård, Torben; Jensen, Rasmus Lund; Maagaard, Steffen

    2016-01-01

    In Danish building code and many design briefings, criteria regarding thermal comfort are defined for “critical” rooms in residential buildings. Identifying the critical room is both difficult and time-consuming for large, multistory buildings. To reduce costs and time, such requirement often...... causes other less critical rooms to be designed with the same constraints as the critical one. In this paper, we propose a method to overcome the difficulty of identifying critical rooms and exploit the design potential of other rooms. First we have defined a set of typical room variations present...

  11. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  12. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  13. Residential instability: a perspective on system imbalance.

    Science.gov (United States)

    Appleby, Lawrence; Desai, Prakash

    1987-10-01

    In an exploration of residential instability and recidivism in chronic mental patients, 215 psychiatric admissions were followed for a year after the initial episode. In addition to an unusually high incidence of residential mobility, a relationship between mobility and number of hospitalizations was evident, as were isolation, disruptive family situations, and homelessness. The needed response of the mental health system is discussed.

  14. Credit Scores, Race, and Residential Sorting

    Science.gov (United States)

    Nelson, Ashlyn Aiko

    2010-01-01

    Credit scores have a profound impact on home purchasing power and mortgage pricing, yet little is known about how credit scores influence households' residential location decisions. This study estimates the effects of credit scores on residential sorting behavior using a novel mortgage industry data set combining household demographic, credit, and…

  15. Does immigrant residential crowding reflect hidden homelessness?

    Directory of Open Access Journals (Sweden)

    Michael Haan

    2011-12-01

    the extent to which heightened levels of residential crowding might reflect “hidden homelessness.” I find mixed evidence to support this link, and, if anything, find some evidence to suggest that the link between residential crowding and hidden homelessness, if one exists, is strongest for the Canadian-born.

  16. Radiation therapy in extrahepatic bile duct carcinoma

    International Nuclear Information System (INIS)

    Mahe, Marc; Romestaing, Pascale; Talon, Bernard; Ardiet, J.M.; Salerno, Nathalie; Sentenac, Irenee; Gerard, J.P.

    1991-01-01

    Fifty-one patients with carcinoma of the extrahepatic bile ducts (EHBD) received radiation therapy between Jan 1980-Dec 1988. The location of the tumors was: proximal third, 20 patients; middle third, 23; distal third, 3; diffuse, 5 patients. Thirty-six patients underwent surgery with complete gross resection in 14 (10/14 with positive margins), incomplete gross resection in 12 and only biopsy in 10. Fifteen patients had only biliary drainage without laparotomy after cytologic diagnosis of malignancy in 11/15. Radiation therapy was done with curative intent after complete or incomplete resection (n=26) and it was palliative in patients who had no resection or only biliary drainage (n=25). Twenty-five patients received external radiation-therapy (ERT) alone to the tumor and lymph nodes (mean dose 45 Gy/2Gy per fraction for cure, 35 Gy/10 fractions for palliation), 8 patients had only iridium-192 ( 192 Ir) implant (50-60 Gy at a 1 cm radius for cure, 30 Gy for palliation), 17 patients had both ERT + 192 Ir(ERT 42.5 Gy + 192 Ir 10-15 Gy for cure; ERT 20 Gy/5 fractions + 192 Ir 20-30 Gy for palliation) and one intra-operative irradiation + ERT. The overall survival rate for the entire group was 55, 28.5 and 15 percent at 12, 24, 36 months and median survival 12 months. Median survival was 22 months in patients treated with curative intent and only 10 months after palliative treatment (p0.03). Among patients who had curative treatment, median survival was 27.5 months after complete gross resection and 13 months after incomplete gross resection (p0.045). After complete gross resection 5/14 patients were alive without evolutive disease at 11, 19, 20, 23 and 41 months, 2 were alive with metastases at 25 and 27 months and 7/14 died of cancer from 7 to 59 months. The rate of complications was low: 3 cholangitis responsive to antibiotics, 1 hemobilia and 2 gastric ulcers. These results are encouraging especially for patients with complete gross resection but they must be

  17. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  18. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Directory of Open Access Journals (Sweden)

    Savchenko Olena

    2017-12-01

    Full Text Available The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  19. Intracellular pH in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I; Hug, M; Greger, R

    1997-01-01

    In order to study the mechanism of H+ and HCO3- transport in a HCO3- secreting epithelium, pancreatic ducts, we have measured the intracellular pH (pHi) in this tissue using the pH sensitive probe BCECF. We found that exposures of ducts to solutions containing acetate/acetic acid or NH4+/NH3...... buffers (20 mmol/l) led to pHi changes in accordance with entry of lipid-soluble forms of the buffers, followed by back-regulation of pHi by duct cells. In another type of experiment, changes in extracellular pH of solutions containing HEPES or HCO3-/CO2 buffers led to significant changes in pHi that did....... Under some conditions, these exchangers can be invoked to regulate cell pH....

  20. Bile Duct Obstruction Secondary to Chronic Pancreatitis in Seven Dogs

    Science.gov (United States)

    Cribb, Alastair E.; Burgener, David C.; Reimann, Keith A.

    1988-01-01

    Seven icteric dogs were determined to have bile duct obstruction secondary to chronic pancreatitis. All dogs had histories of intermittent vomiting and diarrhea. Alkaline phosphatase and alanine aminotransferase activities and total bilirubin concentrations were markedly elevated. Diagnosis was based on exploratory laparotomy and histological examination. Each dog had a 3 to 10 cm mass in the body of the pancreas and obstruction of the common bile duct. Three dogs treated with pancreatectomy, gastrojejunostomy, and cholecystojejunostomy died within five weeks. Three dogs treated with conservative surgical procedures were alive at 8, 16, and 26 months postoperatively. One dog was euthanized because of suspected neoplasia. Hepatic enzyme activity and bilirubin levels decreased markedly in the surviving dogs. Histological examination of the pancreatic masses indicated chronic pancreatitis. Hepatic biopsies revealed evidence of cholestasis. Chronic pancreatitis should be included in the differential diagnoses of icterus, bile duct obstruction, and masses in the pancreas. PMID:17423102

  1. Thyroid cancer in lingual thyroid and thyroglossal duct cyst.

    Science.gov (United States)

    Sturniolo, Giacomo; Vermiglio, Francesco; Moleti, Mariacarla

    2017-01-01

    Ectopy is the most common embryogenetic defect of the thyroid gland, representing between 48 and 61% of all thyroid dysgeneses. Persistence of thyroid tissue in the context of a thyroglossal duct remnant and lingual thyroid tissue are the most common defects. Although most cases of ectopic thyroid are asymptomatic, any disease affecting the thyroid may potentially involve the ectopic tissue, including malignancies. The prevalence of differentiated thyroid carcinoma in lingual thyroid and thyroglossal duct cyst is around 1% of patients affected with the above thyroid ectopies. We here review the current literature concerning primary thyroid carcinomas originating from thyroid tissue on thyroglossal duct cysts and lingual thyroid. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Observationally constrained modeling of sound in curved ocean internal waves: examination of deep ducting and surface ducting at short range.

    Science.gov (United States)

    Duda, Timothy F; Lin, Ying-Tsong; Reeder, D Benjamin

    2011-09-01

    A study of 400 Hz sound focusing and ducting effects in a packet of curved nonlinear internal waves in shallow water is presented. Sound propagation roughly along the crests of the waves is simulated with a three-dimensional parabolic equation computational code, and the results are compared to measured propagation along fixed 3 and 6 km source/receiver paths. The measurements were made on the shelf of the South China Sea northeast of Tung-Sha Island. Construction of the time-varying three-dimensional sound-speed fields used in the modeling simulations was guided by environmental data collected concurrently with the acoustic data. Computed three-dimensional propagation results compare well with field observations. The simulations allow identification of time-dependent sound forward scattering and ducting processes within the curved internal gravity waves. Strong acoustic intensity enhancement was observed during passage of high-amplitude nonlinear waves over the source/receiver paths, and is replicated in the model. The waves were typical of the region (35 m vertical displacement). Two types of ducting are found in the model, which occur asynchronously. One type is three-dimensional modal trapping in deep ducts within the wave crests (shallow thermocline zones). The second type is surface ducting within the wave troughs (deep thermocline zones). © 2011 Acoustical Society of America

  3. Building America Case Study: Raised Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    One of BA-PIRC's longtime Habitat for Humanity partners, S.E. Volusia CO (SEVHFH), was interested in building a home to the new Challenge Home standards. SEVHFH routinely builds ENERGY STAR V3.1 homes. The only modification to their design needed to comply with the Challenge Home criteria was the interior duct requirement. Unwilling to incur the added costs of a foam roof deck or wall heights above 8 feet to accommodate a fur-down chase SEVHFH opted to build a fur-up or raised ceiling chase.

  4. MHD considerations for poloidal-toroidal coolant ducts of self-cooled blankets

    International Nuclear Information System (INIS)

    Hua, T.Q.; Walker, J.S.

    1990-01-01

    Magnetohydrodynamic flows of liquid metals through sharp elbow ducts with rectangular cross sections and with thin conducting walls in the presence of strong uniform magnetic fields are examined. The geometries simulate the poloidaltoroidal coolant channels in fusion tokamak blankets. Analysis for obtaining the three-dimensional numerical solutions are described. Results for pressure drop, velocity profiles and flow distribution are predicted for the upcoming joint ANL/KfK sharp elbow experiment. Results from a parametric study using fusion relevant parameters to investigate the three-dimensional pressure drop are presented for possible applications to blanket designs. 10 refs., 9 refs

  5. Manufactured residential utility wall system (ResCore), overview

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, R. [Oak Ridge National Lab., TN (United States); Lundell, C.; Lau, T.M. [Auburn Univ., AL (United States)

    1997-05-01

    This paper provides an overview of the design and development of a manufactured residential utility wall system referred to as ResCore. ResCore is a self-contained, manufactured, residential utility wall that provides complete rough-in of utilities (power, gas, water, and phone) and other functions (exhaust, combustion make-up air, refrigerant lines, etc.) to serve the residential kitchen, bath, utility, and laundry rooms. Auburn University, Department of Industrial Design faculty and students, supported by a team of graduate student researchers and the project`s advisory team, developed the ResCore. The project was accomplished through a research subcontract from the US Department of Energy administered by the Oak Ridge National Laboratory. The ResCore wall system features a ``layered`` manufacturing technique that allows each major component group--structural, cold water, hot water, drain, gas, electric, etc.--to be built as a separate subassembly and easily brought together for final assembly. The two structural layers are reinforced with bridging that adds strength and also permits firm attachment of plumbing pipes and other systems to the wall frame.

  6. Interprofessional student teams augmenting service provision in residential aged care.

    Science.gov (United States)

    Kent, Fiona; Lai, Francis; Beovich, Bronwyn; Dodic, Miodrag

    2016-09-01

    The aim of this study was to determine the usefulness of student-led interprofessional consultations within residential aged care in augmenting patient care and enhancing student education. Volunteer fourth and final year health-care students conducted interprofessional consultations. In a mixed methods design, residents' health-care changes and perspectives were collected prospectively, and student and educator perceptions were measured by survey and interview. Sixteen aged care residents were consulted by interprofessional teams. Students identified two new health issues and proposed 17 recommendations for referrals and five changes to medication management. At six-weeks follow-up, two recommendations had been acted upon clinically, and two medication changes had been implemented. Reasons for the low uptake of recommendations were determined. Residents, students and educators reported high levels of satisfaction. Residential care facilities offer a useful interprofessional learning environment. Student consultations are positively regarded by patients, students and educators and may augment existing health services. © 2016 AJA Inc.

  7. Estimating elasticity for residential electricity demand in China.

    Science.gov (United States)

    Shi, G; Zheng, X; Song, F

    2012-01-01

    Residential demand for electricity is estimated for China using a unique household level dataset. Household electricity demand is specified as a function of local electricity price, household income, and a number of social-economic variables at household level. We find that the residential demand for electricity responds rather sensitively to its own price in China, which implies that there is significant potential to use the price instrument to conserve electricity consumption. Electricity elasticities across different heterogeneous household groups (e.g., rich versus poor and rural versus urban) are also estimated. The results show that the high income group is more price elastic than the low income group, while rural families are more price elastic than urban families. These results have important policy implications for designing an increasing block tariff.

  8. Analysis of materials in ducts by Compton scattering

    International Nuclear Information System (INIS)

    Gouveia, M.A.G.; Lopes, R.T.; Jesus, E.F.O. de; Camerini, C.S.

    2000-01-01

    This work presents the use of the Compton Scattering Technique as essay, for materials characterization in petroleum ducts. The essay have been accomplished in laboratory ambit, so that the presented results should be analyzed so that the system can come to be used in the field. The inspection was performed using Compton Scattering techniques, with two detectors aligned, in an angle of 90 degrees with a source of Cs-137 with energy of 662 keV. The results demonstrated the good capacity of the system to detect materials deposited in petroleum ducts during petroleum transportation. (author)

  9. A measuring stand for a ducted fan aircraft propulsion unit

    Directory of Open Access Journals (Sweden)

    Hlaváček David

    2014-03-01

    Full Text Available The UL-39 ultra-light aircraft which is being developed by the Department of Aerospace Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, is equipped with an unconventional ducted fan propulsion unit. The unit consists of an axial fan driven by a piston engine and placed inside a duct ended with a nozzle. This article describes the arrangement of a modernised measuring stand for this highly specific propulsion unit which will be able to measure the fan pressure ratio and velocity field in front of and behind the fan and its characteristic curve.

  10. Diverticular bile duct lesion in chronic active hepatitis

    DEFF Research Database (Denmark)

    Vyberg, M

    1989-01-01

    of a not previously described diverticular type were revealed. The diverticuli were of varying shape with a diameter of 30 to 110 microns and a length of 75 to 150 microns budding from small (12 to 25 microns), slightly ectatic bile ducts. The diverticular epithelium was disordered. Some cells appeared as bile duct...... cells, but most were larger, with rounded nuclei, prominent nucleoli and abundant eosinophilic cytoplasm, sometimes with periodic acid-Schiff-positive, diastase-resistant granules. The lesions were only partly surrounded by a basement membrane. They were all embedded in a tight mononuclear inflammatory...

  11. Case report of giant sialolith (megalith) of the Wharton's duct.

    Science.gov (United States)

    Omezli, M M; Ayranci, F; Sadik, E; Polat, M E

    2016-01-01

    Sialolithiasis is the most common disease of salivary glands. Its estimated frequency is 1.2% in the adult population. Sialoliths most commonly occur in the submandibular glands. The sublingual gland and minor salivary glands are rarely affected. The sialolith usually measures from 1 to megalith (> mm) of Wharton's duct have rarely been reported. This case report describes a patient presenting with an unusually large sialolith (megalith) of Wharton's duct, which was 37 mm ×16 mm in the size, the subsequent patient management, the etiology, diagnosis, and its treatment.

  12. Common bile duct stones: analysis of the videolaparoscopic surgical treatment

    Directory of Open Access Journals (Sweden)

    Marco Aurelio Santo

    2012-03-01

    Full Text Available CONTEXT: About 9% of the Brazilian population has gallstones and the incidence increases significantly with aging. The choledocholithiasis is found around 15% of these patients, and a third to half of these cases presented as asymptomatic. Once the lithiasis in the common bile duct is characterized through intraoperative cholangiography, the laparoscopic surgical exploration can be done through the transcystic way or directly through choledochotomy. OBJECTIVE: To evaluate the results and outcomes of the laparoscopic treatment of common bile duct lithiasis. METHODS: Seventy consecutive patients were evaluated. They prospectively underwent the treatment of the lithiasis in the common bile duct and the exploration ways were compared according to the following parameters: criteria on their indication, success in the clearance, surgical complications. It was verified that about ½ of the choledocholithiasis carriers did not show any expression of predictive factors (clinical antecedents of jaundice and/or acute pancreatitis, compatible sonographic data and the pertaining lab tests. The laparoscopic exploration through the transcystic way is favored when there are no criteria for the practice of primary choledochotomy, which are: lithiasis in the proximal bile duct, large (over 8 mm or numerous calculi (multiple calculosis. RESULTS: The transcystic way was employed in about 50% of the casuistic and the choledochotomy in about 30%. A high success rate (around 80% was achieved in the clearance of the common bile duct stones through laparoscopic exploration. The transcystic way, performed without fluoroscopy or choledochoscopy, attained a low rate of success (around 45%, being 10% of those by transpapilar pushing of calculi less than 3 mm. The exploration through choledochotomy, either primary or secondary, if the latter was performed after the transcystic route failure, showed high success rate (around 95%. When the indication to choledochotomy was

  13. Congenital anomalies of the mesonephric duct and fertility.

    Science.gov (United States)

    Tzvetkova, P

    2007-01-01

    Agenesia of deferential duct and the others congenital malformations of mesonephronical duct are often encountering condition in andrological practice. This study presents the possibilities of reproductive medicine to restore the male fertility and concentrates on biological and clinical aspects of malformations of mesonephronic duct like factors for excretory male infertility. The investigations including 104 patients (mean age 30.25+/-1.91 years old) with congenital anomalies of mesonephronical duct with: Agenesia of mesonephronical derivates - case with unilateral agenesia of the deferent duct, kidney and left urether (n=1); Dysgenesia of the epididymis (n=5); Cysts of the epididymis (n=47); Agenesia of the deferential duct (n=48); Aplasia of the eja-culatorial duct (n=3). The following methods were used: open testicular biopsy by Vilar; objective findings in situ operation; bilateral epididymo - and deferentovesiculography; morphological specimens of the testicular and epididymal tissues; enzymohistochemical analysis of testicular specimens; the ejaculates and morphological analysis of spermatozoa were assessed for quality parameters by the standard protocol; enzymocytological research of spermatozoa in seminal fluid; biochemical analysis of seminal fluid fructose and citric acid concentrations; radioimmunoassay for measurements of blood FSH and testosterone concentration. Most often observed localization of the malformations of mesonephronic canal is bilateral at 54.81%. The testicular specimens proved preserved testicular architecture and spermatogenesis, and the epididymal slides showed dilatation of the epididymal tubules, which were overfilled with a lot of spermatozoa. The strongest expression of the enzymichistochemical NADH-TR reactions is in the Sertoli cells. We observed spermatozoa with disrup-ted configuration among which the abnormalities in sperm head and acrosome were predominated. The biochemical analysis of seminal fluid proves normal citric

  14. Simultaneous Papillary Carcinoma in Thyroglossal Duct Cyst and Thyroid

    Directory of Open Access Journals (Sweden)

    Gustavo Cancela e Penna

    2017-01-01

    Full Text Available Thyroglossal duct cyst (TDC is a cystic expansion of a remnant of the thyroglossal duct tract. Carcinomas in the TDC are extremely rare and are usually an incidental finding after the Sistrunk procedure. In this report, an unusual case of a 36-year-old woman with concurrent papillary thyroid carcinoma arising in the TDC and on the thyroid gland is presented, followed by a discussion of the controversies surrounding the possible origins of a papillary carcinoma in the TDC, as well as the current management options.

  15. ATP release, generation and hydrolysis in exocrine pancreatic duct cells

    DEFF Research Database (Denmark)

    Kowal, Justyna Magdalena; Yegutkin, G.G.; Novak, Ivana

    2015-01-01

    Extracellular adenosine triphosphate (ATP) regulates pancreatic duct function via P2Y and P2X receptors. It is well known that ATP is released from upstream pancreatic acinar cells. The ATP homeostasis in pancreatic ducts, which secrete bicarbonate-rich fluid, has not yet been examined. First, our...... dephosphorylated through ecto-nucleoside triphosphate diphosphohydrolase (NTPDase2) and ecto-5'-nucleotidase/CD73 reactions, with respective generation of adenosine diphosphate (ADP) and adenosine and their maintenance in the extracellular medium at basal levels. In addition, Capan-1 cells express counteracting...

  16. Cutaneous Metastases from Salivary Duct Carcinoma of the Submandibular Gland

    Directory of Open Access Journals (Sweden)

    Wahida Chakari

    2017-12-01

    Full Text Available Salivary duct carcinoma is a rare and highly aggressive malignant neoplasm that frequently metastasises to other organs, but cutaneous metastasis is uncommon. There are only 6 cases reported in the literature with metastases to the skin and in all cases the tumour originates from the parotid gland. We present a case of skin metastases from the submandibular gland that was mistaken for basal cell carcinoma. To the best of our knowledge, this is the first reported case of salivary duct carcinoma arising from the submandibular gland with cutaneous metastases.

  17. Adenoma of the distal common bile duct -a case report-

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Hyun Gon; Han, Ho Seong; Ko, Gyung Hyuck; Kim, Jae Hyoung; Kim, Hyung Jin; Chung, Sung Hoon

    1991-01-01

    On rare occasions, Obstructive Jaundice may be caused by a benign tumor of the biliary tract. We describe a patient in whom the diagnosis of an adenoma of the distal common bile duct (CBD) was established. The CT showed a soft tissue density mass in the distal CBD and diffuse dilatation of the intrahepatic duct, gall the bladder, and CBD. Endoscopic retrograde cholangiopnacreatography showed an irregularly marginated polypoid mass in the distal CBD. The clinical, radiological, and histological features of this neoplasm are reviewed. The clinical, radiological and histological features of this neoplasm are reviewed

  18. Ducted fan inlet/exit and rotor tip flow improvements for vertical lift systems

    Science.gov (United States)

    Akturk, Ali

    The current research utilized experimental and computational techniques in 5" and 22" diameter ducted fan test systems that have been custom designed and manufactured. Qualitative investigation of flow around the ducted fan was also performed using smoke flow visualizations. Quantitative measurements consisted of 2D and 3D velocity measurements using planar and Stereoscopic Particle Image Velocimetry (PIV and SPIV), high resolution total pressure measurements using Kiel total pressure probes and real time six-component force and torque measurements. The computational techniques used in this thesis included a recently developed radial equilibrium based rotor model(REBRM) and a three dimensional Reynolds-Averaged Navier Stokes (RANS) based CFD model. A radial equilibrium based rotor model (REBRM) developed by the author was effectively integrated into a three-dimensional RANS based computational system. The PIV measurements and computational flow predictions using (REBRM) near the fan inlet plane were in a good agreement at hover and forward flight conditions. The aerodynamic modifications resulting from the fan inlet flow distortions in forward flight regime were clearly captured in 2D PIV results. High resolution total pressure measurements at the downstream of the fan rotor showed that tip leakage, rotor hub separation, and passage flow related total pressure losses were dominant in hover condition. However, the losses were dramatically increased in forward flight because of inlet lip separation and distortion. A novel ducted fan inlet flow conditioning concept named "Double Ducted Fan" (DDF) was developed. The (DDF) concept has a potential to significantly improve the performance and controllability of VTOL UAVs and many other ducted fan based vertical lift systems. The new concept that will significantly reduce the inlet lip separation related performance penalties used a secondary stationary duct system to control "inlet lip separation" occurring especially at

  19. Energy options for residential buildings assessment

    International Nuclear Information System (INIS)

    Rezaie, Behnaz; Dincer, Ibrahim; Esmailzadeh, Ebrahim

    2013-01-01

    Highlights: ► Studying various building energy options. ► Assessing these options from various points. ► Comparing these options for better environment and sustainability. ► Proposing renewable energy options as potential solutions. - Abstract: The building sector, as one of the major energy consumers, demands most of the energy research to assess different energy options from various aspects. In this paper, two similar residential buildings, with either low or high energy consumption patterns, are chosen as case studies. For these case studies, three different renewable energy technology and three different hybrid systems are designed for a specified size. Then, the environmental impact indices, renewable energy indices, and the renewable exergy indices have been estimated for every energy options. Results obtained show that the hybrid systems (without considering the economics factors) are superior and having top indices. The importance of the energy consumption patterns in buildings are proven by the indices. By cutting the energy consumption to about 40% the environment index would increase by more than twice (2.1). Utilization of the non-fossil fuels is one part of the solution to environmental problems while energy conservation being the other. It has been shown that the re-design of the energy consumption model is less complex but more achievable for buildings.

  20. Optimizing Hydronic System Performance in Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L.; Faakye, O.

    2013-10-01

    Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

  1. Residential radon survey in Finland

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Castren, O.

    1993-02-01

    The study measured the indoor radon concentration in the dwellings of 3074 persons, selected randomly from the central population register of Finland. Alpha track detectors and two consecutive half year measuring periods were used. The national mean of indoor radon concentration for persons living in low-rise residential buildings as well as blocks of flats was 145 and 82 Bq/m 3 , respectively. The mean for the total population was 123 Bq/m 3 . Based on the decision of the Ministry of Social Affairs and Health in 1992, the indoor radon concentration should not exceed 400 Bq/m 3 in already existing houses, the target for new construction being less than 200 Bq/m 3 . According to the study, the percentage of the Finnish population living in houses with an indoor radon concentration exceeding 200, 400 and 800 Bq/m 3 was 12.3 %, 3.6 % and 1.0 %

  2. CFD analysis of turboprop engine oil cooler duct for best rate of climb condition

    Science.gov (United States)

    Kalia, Saurabh; CA, Vinay; Hegde, Suresh M.

    2016-09-01

    Turboprop engines are widely used in commuter category airplanes. Aircraft Design bureaus routinely conduct the flight tests to confirm the performance of the system. The lubrication system of the engine is designed to provide a constant supply of clean lubrication oil to the engine bearings, the reduction gears, the torque-meter, the propeller and the accessory gearbox. The oil lubricates, cools and also conducts foreign material to the oil filter where it is removed from further circulation. Thus a means of cooling the engine oil must be provided and a suitable oil cooler (OC) and ducting system was selected and designed for this purpose. In this context, it is relevant to study and analyse behaviour of the engine oil cooler system before commencing actual flight tests. In this paper, the performance of the oil cooler duct with twin flush NACA inlet housed inside the nacelle has been studied for aircraft best rate of climb (ROC) condition using RANS based SST K-omega model by commercial software ANSYS Fluent 13.0. From the CFD analysis results, it is found that the mass flow rate captured and pressure drop across the oil cooler for the best ROC condition is meeting the oil cooler manufacturer requirements thus, the engine oil temperature is maintained within prescribed limits.

  3. Testing and analyses of a high temperature duct for gas-cooled reactors

    International Nuclear Information System (INIS)

    Black, W.E.; Roberge, A.; Felten, P.; Bastien, D.

    1979-01-01

    A 0.6 scale model of a steam cycle gas-cooled reactor high temperature duct was tested in a closed loop helium facility. The object of the test series was to determine: 1) the thermal effects of gas permeation within the thermal barrier, 2) the plastic deformation of the metallic components, and 3) the thermal performance of the fibrous insulation. A series of tests was performed with thermal cyclings from 100 0 C to 760 0 C at 50 atmospheres until the system thermal performance had stabilized hence enabling predictions for the reactor life. Additional tests were made to assess permeation by deliberately simulating sealing weld failures thereby allowing gas flow by-pass within the primary thermal barrier. After 100 cycles the entire primary structure was found to have performed without structural failure. Due to high pressures exerted by the insulation on the cover plates and a design oversight, the thin seal sheets were unable to expand in an anticipated manner. Local buckling resulted. The insulation retained an acceptable degree of resiliency. However, some fiber damage was observed within both the high and low temperature insulation blankets. A thermal analysis was conducted to correlate the hot duct heat transfer results with those obtained from the analytical techniques used for the HTGR design using a computer thermal model representative of the duct and test setup. The thermal performance of the insulation, the temperature gradient through the structural components, the heating load to the cooling system and the permeation flow effect on heat transfer were verified. Exellent correlation between the experimental data and the analytical techniques were obtained

  4. Congenital double bile duct presenting as recurrent cholangitis in a child

    Directory of Open Access Journals (Sweden)

    K.D. Chakravarty

    2015-12-01

    Full Text Available Double common bile duct (DCBD is a rare congenital anomaly. Most of these bile duct anomalies are associated with bile duct stones, anomalous pancreaticobiliary junction (APBJ, pancreatitis and bile duct or gastric cancers. Early detection and treatment is important to avoid long term complications. Surgical resection of the anomalous bile duct and reconstruction of the biliary enteric anastomosis is the treatment of choice. We report a rare case of DCBD anomaly in a girl, who presented with recurrent cholangitis. She had type Va DCBD anomaly. She underwent successful resection of the bile duct and reconstruction of the biliary enteric anastomosis. Preoperative imaging and diagnosis of the congenital biliary anomaly is very important to avoid intraoperative bile duct injury. Review of the literature shows very few cases of type Va DCBD, presenting with either bile duct stones or APBJ.

  5. Convective heat transfer in airflow through a duct with wall thermal radiation

    International Nuclear Information System (INIS)

    Chandratilleke, T T; Narayanaswamy, R; Wangdhamkoom, P

    2010-01-01

    This paper presents a numerical investigation on airflow through a heated horizontal rectangular duct wherein the model considers the combined modes of natural and forced convection heat transfer and the thermal radiation from duct walls. The duct periphery is differentially heated with known temperature profiles imposed on the two opposite vertical sidewalls while the other two walls are treated as adiabatic. The air enters into the duct hydrodynamically fully developed and flows steadily under laminar conditions undergoing thermal development within the duct. Considering several temperature profiles on the two vertical sidewalls, the numerical simulation generates the heat transfer rates and associated fluid flow patterns in the duct for a range of airflow rates, duct aspect ratios and surface emissivity. The variation of local Nusselt number at duct walls and the fluid flow patterns are critically examined to identify thermal instabilities and the significance of wall thermal radiation effects on the overall heat transfer rates.

  6. A prospective study to evaluate a residential community reintegration program for patients with chronic acquired brain injury

    NARCIS (Netherlands)

    Geurtsen, G.J.; Heugten, C.M. van; Martina, J.D.; Rietveld, A.C.; Meijer, R.; Geurts, A.C.H.

    2011-01-01

    OBJECTIVE: To examine the effects of a residential community reintegration program on independent living, societal participation, emotional well-being, and quality of life in patients with chronic acquired brain injury and psychosocial problems hampering societal participation. DESIGN: A prospective

  7. Decline of the performance of a portable axial-flow fan due to the friction and duct bending loss of a connected flexible duct.

    Science.gov (United States)

    Ojima, Jun

    2017-03-28

    In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.

  8. ß-adrenergic regulation of ion transport in pancreatic ducts: Patch-clamp study of isolated rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I

    1998-01-01

    . METHODS: Small intralobular ducts were isolated from rat pancreas and studied in vitro by the whole-cell patch clamp technique. Cell membrane voltages and currents were indicators of cellular ion transport. In some ducts, intracellular Ca2+ activity was measured by fluorescence optical methods. RESULTS...... much smaller effects. At comparable concentrations, it depolarized Vm by a few millivolts. Neither agonist had significant effects on intracellular Ca2+. CONCLUSIONS: This study provides the first direct evidence that adrenergic stimulation, namely, that of beta-adrenoceptors, controls ion transport...

  9. Are all customers really the same? Comparing service quality and satisfaction between residential and business telecommunications customers

    Directory of Open Access Journals (Sweden)

    Charles Makanyeza

    2016-06-01

    Research purpose: The study sought to examine differences in the relationship between service quality and customer satisfaction because of the type of customer. Motivation for the study: Previous studies have not examined the relationship between service quality and customer satisfaction between residential and business customers. Research design, approach and method: The study used a cross-section of 203 customers (108 residential and 95 business in the fixed-line telecommunications sector in Zimbabwe. Moderated regression analysis was performed to test the research hypotheses. Main findings: It was established that the customer category (residential versus business does not moderate the effect of service quality on customer satisfaction. Practical/managerial implications are, generally, that it is not necessary to segment customers by customer category (residential versus business when managing service quality to achieve customer satisfaction. Contribution/value add: The main theoretical contribution of the study is the comparison of the effect of service quality on customer satisfaction between residential and business customers.

  10. Duplication of the Extrahepatic Bile Duct in Association with Choledocholithiasis as Depicted by MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Park, Do Hyun; Shin, Hyeong Cheol; Kim, Il Young; Park, Sang Heum; Jung, Eun Jung; Kim, Chang Ho [Soonchunhyang University, Cheonan Hospital, Cheonan (Korea, Republic of)

    2008-12-15

    We report here on an extremely rare case of duplicated extrahepatic bile ducts that was associated with choledocholithiasis, and this malady was visualized by employing the minimum intensity projection images with using multi-detector row CT. The presence of duplicated extrahepatic bile ducts with a proximal communication, and the ducts were joined distally and they subsequently formed a single common bile duct, has not been previously reported

  11. Duplication of the Extrahepatic Bile Duct in Association with Choledocholithiasis as Depicted by MDCT

    International Nuclear Information System (INIS)

    Kim, Sang Won; Park, Do Hyun; Shin, Hyeong Cheol; Kim, Il Young; Park, Sang Heum; Jung, Eun Jung; Kim, Chang Ho

    2008-01-01

    We report here on an extremely rare case of duplicated extrahepatic bile ducts that was associated with choledocholithiasis, and this malady was visualized by employing the minimum intensity projection images with using multi-detector row CT. The presence of duplicated extrahepatic bile ducts with a proximal communication, and the ducts were joined distally and they subsequently formed a single common bile duct, has not been previously reported

  12. Integrated Strip Foundation Systems for Small Residential Buildings

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2010-01-01

    A prefabricated lightweight element was designed for a strip foundation that was used on site as the bases of two small residential buildings, in this case single-family houses; one was built with a double-brick exterior wall separated by mineral fiber insulation and the other was built with a wood......-stud exterior wall with mineral fiber insulation. The element was placed on a stable surface underneath the top soil layer, just 0.25 m below the finished ground surface. The prefabricated element was designed to comply with the requirements of a high energy-efficient performance stipulated in the new Danish...

  13. Evaluation of Multi Residential House Renovation Efficiency

    Directory of Open Access Journals (Sweden)

    Daiva Rapcevičienė

    2011-03-01

    Full Text Available Analyzed multi residential house renovation investment projects efficiency evaluation methods: economic-social, and environmental, as well as key financial valuation methods: simple pay-back period, the energy cost savings, the net present value, internal rate of return. Building walls condition regenerative rate which is used to evaluate investments in energy-saving measures is also discussed. According to reconstruction investments of multi residential house, three government financing programs of multi residential house are evaluated and selected the most effective program by comparing financial valuation methods taking and without taking into account building walls condition regenerative rate. Article in Lithuanian

  14. Resin duct characteristics in the wood of fire-scarred North American conifers

    Science.gov (United States)

    Estelle Arbellay; Markus Stoffel; Elaine K. Sutherland; Kevin T. Smith; Donald A. Falk

    2013-01-01

    Traumatic resin ducts form in xylem and phloem tissue of conifers in response to abiotic wounding, fungal invasion, and insect attack. Little is known about resin duct characteristics in the wood of fire-scarred trees. The aim of this study is to quantify changes in traits of both axial and radial resin ducts, along with those of associated epithelial cells and...

  15. Cooling air recycling for gas turbine transition duct end frame and related method

    Science.gov (United States)

    Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz

    2002-01-01

    A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.

  16. Outcome of 49 repairs of bile duct injuries after laparoscopic cholecystectomy

    NARCIS (Netherlands)

    Schol, F. P.; Go, P. M.; Gouma, D. J.

    1995-01-01

    Treatment of bile duct injuries after laparoscopic cholecystectomy is still under discussion. The aim of this study was to evaluate the results of end-to-end or biliodigestive anastomosis for various types of bile duct injury. Patient charts of 49 (0.81%) classified bile duct injuries from a

  17. Primary Pancreatic Lymphoma with Severe Dilatation of Pancreatic Duct: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Tae Wook; Heo, Suk Hee; Shin, Sang Soo; Jeong, Yong Yeon; Kang, Heoung Keun; Choi, Yoo Duk [Chonnam National University Hospital, Gwangju (Korea, Republic of); Kim, Jin Woong [Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2010-04-15

    Primary pancreatic lymphoma is extremely rare and usually consists of a bulky tumor without internal necrosis and severe dilatation of the pancreatic duct. We report the unusual CT and MRI findings of a primary pancreatic lymphoma in a 27-years-old man, associated with severe dilatation of the pancreatic duct, common bile duct, and internal necrosis

  18. High-Lift Low Reynolds Number Aerofoils With Specified Pressure Drop for Ducted Wind Turbine

    NARCIS (Netherlands)

    Tang, J.; van Bussel, G.J.W.

    2017-01-01

    A new high-lift aerofoil modification for the duct has been developed and will be experimentally tested in a small wind tunnel. Aerofoils for such wind tunnel ducts typically operate in the low Reynolds number range from 2 × 105 to 6 × 105. The effect of a duct and of rotor on power and pressure

  19. An Appraisal of Duct-Related Microwave Link Degradation in Nigeria

    African Journals Online (AJOL)

    Studies have revealed considerable prevalence of surface ducts in Nigeria. This effort examines the climatic conditions that give rise to ducts and assesses their potential for degradation of microwave links in the country. The result based on analysis of clear-air meteorological data shows prevalence of strong surface ducts ...

  20. Effect of duct orientation on particle deposition in the human ...

    African Journals Online (AJOL)

    The simulations of macron size particles (1-5 μm) show that the existence of alveolar re-circulation and gravity orientation are key factors in determining the deposition in the last four generations of the human respiratory tract. Keywords: duct orientation, particle deposition, respiratory tract, discretization approach

  1. Discontinuous finite element treatment of duct problems in transport calculations

    International Nuclear Information System (INIS)

    Mirza, A. M.; Qamar, S.

    1998-01-01

    A discontinuous finite element approach is presented to solve the even-parity Boltzmann transport equation for duct problems. Presence of ducts in a system results in the streaming of particles and hence requires the employment of higher order angular approximations to model the angular flux. Conventional schemes based on the use of continuous trial functions require the same order of angular approximations to be used everywhere in the system, resulting in wastage of computational resources. Numerical investigations for the test problems presented in this paper indicate that the discontinuous finite elements eliminate the above problems and leads to computationally efficient and economical methods. They are also found to be more suitable for treating the sharp changes in the angular flux at duct-observer interfaces. The new approach provides a single-pass alternate to extrapolation and interactive schemes which need multiple passes of the solution strategy to acquire convergence. The method has been tested with the help of two case studies, namely straight and dog-leg duct problems. All results have been verified against those obtained from Monte Carlo simulations and K/sup +/ continuous finite element method. (author)

  2. Optimizing the Treatment of Acute Duct-Destructive Pancreatitis

    Science.gov (United States)

    Zhakiev, Bazylbek S.; Karsakbayev, Uteugali G.; Kelimberdiev, Mersaid S.; ?uhamedgalieva, Bodagoz M.; K?nonenko, Aleksander F.

    2016-01-01

    The search for new methods for treating duct-destructive pancreatitis is a relevant problem. Endogenous intoxication and oxidative stress that accompany acute pancreatitis often progress even after surgery, which forces one to search for additional possibilities of preventing these severe consequences. This research studied the effect of small…

  3. Modelling the Pressure Profile for Optical Cables in Ducts

    NARCIS (Netherlands)

    Snippe, A.; Bresser, O.R.; Hoekstra, Sipke; Griffioen, A.

    2013-01-01

    The longitudinal pressure profile is an important parameter when calculating the correct blowing force during the process of installing optical fiber cables using the viscous flow of air. This paper presents a model of the pressure inside the duct that contains a moving cable. This new model of the

  4. Low-noise flow valve for air ducts

    Science.gov (United States)

    Gallo, E. A.

    1970-01-01

    Valve assembly controls air flow from feeder into main duct, with minimum of turbulence, friction, pressure differential, and noise. Valve consists of damper, deflector, and spring. Streamlining of damper and deflector merges flow smoothly, while spring keeps damper and deflector in contact and eliminates valve chatter and damping vibrations.

  5. Thyroglossal Duct Papillary Thyroid Carcinoma and Synchronous Lingual Thyroid Atypia

    Directory of Open Access Journals (Sweden)

    Timothy Yoo

    2016-01-01

    Full Text Available Thyroglossal duct and lingual thyroid ectopic lesions are exceedingly rare synchronous findings. Papillary thyroid carcinoma of these ectopic thyroid sites is well understood but still a rare finding. This case points to some management nuances in regard to ectopic thyroid screening with imaging and also shows the effectiveness of minimally invasive transoral robotic surgery for lingual thyroid.

  6. Percutaneous management of bile duct injury after laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Islim, F.; Ors, S.; Salik, A.; Guven, K.; Yanar, F.; Alis, H.

    2012-01-01

    Full text: Introduction: The risk of bile duct injury after laparoscopic cholecystectomy is higher than open cholecystectomy. Objective: To discuss the importance of minimally invasive treatment options in the management of bile duct injuries after laparoscopic cholecystectomy and to present our approach in the management. Materials and methods: Management of 25 patients with symptomatic bile duct injury after laparoscopic cholecystectomy was retrospectively evaluated. Percutaneous collection drainage, endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTC) and percutaneous biliary drainage were performed for the management of the patients. Results: Mean age of the patients (15 women, 10 men) was 55. Either ultrasonography or computed tomography guided percutaneous drainage was performed in 13 patients. 9 of them completely recovered only with percutaneous drainage. In 4 of them ERCP was performed because of high drainage volume. In 9 of the patients with jaundice and high bilirubin levels ERCP was performed as the first option. And 3 patients were reoperated because of acute abdomen signs. ERCP, MRCP and PTC revealed type A in 7, type E2 in 3, type E3 in 3 and type E4 in 1 of the patients according to Strasberg classification. Conclusion: Presenting symptoms of the patients with symptomatic bile duct injury are useful in the determination of the treatment option.

  7. Spontaneous bile duct perforation in an infant, managed with simple ...

    African Journals Online (AJOL)

    Spontaneous bile duct perforation is a very rare but important cause of surgical jaundice in pediatric patients and one of the most common causes of surgical jaundice during infancy after biliary atresia. Preoperative diagnosis may not be possible in most of the cases. The exact cause of the perforation remains unclear.

  8. Persistent Mullerian duct syndrome: the hidden normal or abnormal ...

    African Journals Online (AJOL)

    normal or abnormal anatomy and the value of laparoscopy. Abdullah Alwabari, Lalit Parida and Ahmed H. Al-Salem. Persistent Mullerian duct syndrome (PMDS) is a rare disorder of male sexual development. It is characterized by the presence of a uterus, fallopian tubes, and upper vagina in an otherwise phenotypically ...

  9. Laparoscopic treatment of the peritoneo-vaginal duct persistences in ...

    African Journals Online (AJOL)

    Laparoscopic treatment of the peritoneo-vaginal duct persistences in children at Sylvanus Olympio Teaching Hospital of Lomé (Togo) ... The results were considered good in absence of recurrence and bad if recurrence occurred. Results: With 4 over the 21 patients (19.04%), the diagnosis of a controlateral PPV was done ...

  10. T-tube vs Primary Common Bile Duct Closure

    Directory of Open Access Journals (Sweden)

    M R Joshi

    2010-09-01

    Full Text Available INTRODUCTION: Closure of the common bile duct over T-tube after exploration is a widely practiced traditional method. However, its use may give rise to many complications. We do primary closure of common bile duct after exploration. Aim of the study is to see the efficacy and safety of the primary closure. METHODS: Study was carried out to compare the results of both the techniques from 2006 to 2009 in the cases proven to have common bile duct stone with or without the features of obstructive jaundice. Post operative hospital stay and morbidities related to both the groups were recorded and analyzed. RESULTS: There were total 71 cases included in the study. Thirty one in T-tube group and 40 in primary closure group. T-tube was removed in most of the cases after three weeks where as average time of drain removal in primary closure group is 5.79 +/-1.79 days. Incidence of retained stone was equal in each group. Major complication in T-tube group is biliary peritonitis in four patients at the time of T-tube removal whereas none of the patient from primary closure group suffered from such major complication. CONCLUSIONS: Primary closure after the common bile duct exploration is safe and it helps to avoid the morbidities related to T-tube. Keywords: Choledocholithiasis, Primary closure, retained stone, T-tube, Ureterorenoscope.

  11. Analytical study of flow phenomena in SSME turnaround duct geometries

    Science.gov (United States)

    Mclallin, K. L.

    1985-01-01

    The SSME fuel turbopump hot gas manifold was identified as a source of loss and flow distortion which significantly affects the performance and durability of both the drive turbine and the LOX injector area of the main combustion chamber. Two current SSME geometries were studied, the full power level (FPL) and the first manned orbital flight (FMOF) configuration. The effects of turnaround duct geometry on flow losses and distortions, by varying wall curvature and flow area variation in the 180 deg turnaround region were examined. The effects of the duct inlet flow phenomena such as the radial distortion of the inlet flow and inlet swirl level on turnaround duct performance were also investigated. It is shown that of the two current geometries, the FMOF configuration had lower pressure losses and generated less flow distortion, but had a small flow separation bubble at the 180 deg turnaround exit. It is found that by optimizing wall curvature and flow diffusion in the turnaround, improved duct performance can be achieved.

  12. Associated patent urachus and patent omphalo– mesenteric duct in ...

    African Journals Online (AJOL)

    connecting the yolk sac with the intestine. During the fetal life, the vitelline duct tends to obliterates itself till to disappear. The partial failure of this obliteration ... has been performed according to the ethical standards of the Committee on Human Experimentation of the institution in which the experiments were conducted or in.

  13. Two phase flow combustion modelling of a ducted rocket

    NARCIS (Netherlands)

    Stowe, R.A.; Dubois, C.; Harris, P.G.; Mayer, A.E.H.J.; Champlain, A. de; Ringuette, S.

    2001-01-01

    Under a co-operative program, the Defence Research Establishment Valcartier and Université Laval in Canada and the TNO Prins Maurits Laboratory in the Netherlands have studied the use of a ducted rocket for missile propulsion. Hot-flow direct-connect combustion experiments using both simulated and

  14. A pilot study of bendamustine in advanced bile duct cancer.

    Science.gov (United States)

    Schoppmeyer, Konrad; Kreth, Florian; Wiedmann, Marcus; Mössner, Joachim; Preiss, Rainer; Caca, Karel

    2007-07-01

    We performed a pilot study to evaluate the safety and tolerability of bendamustine in patients with advanced hilar bile duct cancer and impaired liver function. Six patients with histologically proven, unresectable adenocarcinoma of the hilar bile duct were treated with bendamustine 140 mg/m intravenously on day 1 of the first cycle and with bendamustine 100 mg/m on days 1 and 2 of the second to fourth cycle. Treatment cycles were repeated every 21 days. Primary endpoint was the safety and tolerability of the treatment; secondary endpoints were response rate, time to progression and overall survival. Transient lymphopenia grade 3 occurred in all six patients. No other grade 3 or 4 toxicities were present. The most common nonhematologic toxicity was mouth dryness grade 2 in six patients. Three patients had stable disease. No partial or complete responses were observed. Median time to progression was 3.3 months; median overall survival was 6 months. Our study demonstrates that bendamustine can be safely administered in patients with hilar bile duct cancer and impaired liver function. A potential role of bendamustine in combination therapies for bile duct cancer will be a subject of further trials.

  15. 12 CFR 541.16 - Improved residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Improved residential real estate. 541.16... REGULATIONS AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.16 Improved residential real estate. The term improved residential real estate means residential real estate containing offsite or other improvements...

  16. 12 CFR 541.23 - Residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Residential real estate. 541.23 Section 541.23... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.23 Residential real estate. The terms residential real estate... home used in part for business); (c) Other real estate used for primarily residential purposes other...

  17. Causes and Prevention of Laparoscopic Bile Duct Injuries

    Science.gov (United States)

    Way, Lawrence W.; Stewart, Lygia; Gantert, Walter; Liu, Kingsway; Lee, Crystine M.; Whang, Karen; Hunter, John G.

    2003-01-01

    Objective To apply human performance concepts in an attempt to understand the causes of and prevent laparoscopic bile duct injury. Summary Background Data Powerful conceptual advances have been made in understanding the nature and limits of human performance. Applying these findings in high-risk activities, such as commercial aviation, has allowed the work environment to be restructured to substantially reduce human error. Methods The authors analyzed 252 laparoscopic bile duct injuries according to the principles of the cognitive science of visual perception, judgment, and human error. The injury distribution was class I, 7%; class II, 22%; class III, 61%; and class IV, 10%. The data included operative radiographs, clinical records, and 22 videotapes of original operations. Results The primary cause of error in 97% of cases was a visual perceptual illusion. Faults in technical skill were present in only 3% of injuries. Knowledge and judgment errors were contributory but not primary. Sixty-four injuries (25%) were recognized at the index operation; the surgeon identified the problem early enough to limit the injury in only 15 (6%). In class III injuries the common duct, erroneously believed to be the cystic duct, was deliberately cut. This stemmed from an illusion of object form due to a specific uncommon configuration of the structures and the heuristic nature (unconscious assumptions) of human visual perception. The videotapes showed the persuasiveness of the illusion, and many operative reports described the operation as routine. Class II injuries resulted from a dissection too close to the common hepatic duct. Fundamentally an illusion, it was contributed to in some instances by working too deep in the triangle of Calot. Conclusions These data show that errors leading to laparoscopic bile duct injuries stem principally from misperception, not errors of skill, knowledge, or judgment. The misperception was so compelling that in most cases the surgeon did not

  18. 77 FR 65941 - Energy Conservation Program: Test Procedures for Residential Dishwashers, Dehumidifiers, and...

    Science.gov (United States)

    2012-10-31

    ... designed to improve energy efficiency. (All references to EPCA refer to the statute as amended through the... cooking products,'' as used in this notice, refers to residential electric and gas kitchen ovens, ranges... section shall be reasonably designed to produce test results which measure energy efficiency, energy use...

  19. Determination of sustainable values for the parameters of the construction of residential buildings

    Science.gov (United States)

    Grigoreva, Larisa; Grigoryev, Vladimir

    2018-03-01

    For the formation of programs for housing construction and planning of capital investments, when developing the strategic planning companies by construction companies, the norms or calculated indicators of the duration of the construction of high-rise residential buildings and multifunctional complexes are mandatory. Determination of stable values of the parameters for the high-rise construction residential buildings provides an opportunity to establish a reasonable duration of construction at the planning and design stages of residential complexes, taking into account the influence of market conditions factors. The concept of the formation of enlarged models for the high-rise construction residential buildings is based on a real mapping in time and space of the most significant redistribution with their organizational and technological interconnection - the preparatory period, the underground part, the above-ground part, external engineering networks, landscaping. The total duration of the construction of a residential building, depending on the duration of each redistribution and the degree of their overlapping, can be determined by one of the proposed four options. At the same time, a unified approach to determining the overall duration of construction on the basis of the provisions of a streamlined construction organization with the testing of results on the example of high-rise residential buildings of the typical I-155B series was developed, and the coefficients for combining the work and the main redevelopment of the building were determined.

  20. Determination of sustainable values for the parameters of the construction of residential buildings

    Directory of Open Access Journals (Sweden)

    Grigoreva Larisa

    2018-01-01

    Full Text Available For the formation of programs for housing construction and planning of capital investments, when developing the strategic planning companies by construction companies, the norms or calculated indicators of the duration of the construction of high-rise residential buildings and multifunctional complexes are mandatory. Determination of stable values of the parameters for the high-rise construction residential buildings provides an opportunity to establish a reasonable duration of construction at the planning and design stages of residential complexes, taking into account the influence of market conditions factors. The concept of the formation of enlarged models for the high-rise construction residential buildings is based on a real mapping in time and space of the most significant redistribution with their organizational and technological interconnection - the preparatory period, the underground part, the above-ground part, external engineering networks, landscaping. The total duration of the construction of a residential building, depending on the duration of each redistribution and the degree of their overlapping, can be determined by one of the proposed four options. At the same time, a unified approach to determining the overall duration of construction on the basis of the provisions of a streamlined construction organization with the testing of results on the example of high-rise residential buildings of the typical I-155B series was developed, and the coefficients for combining the work and the main redevelopment of the building were determined.