WorldWideScience

Sample records for residential air toxics

  1. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  2. National Air Toxic Assessments (NATA) Results

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Air Toxics Assessment was conducted by EPA in 2002 to assess air toxics emissions in order to identify and prioritize air toxics, emission source types...

  3. 2011 NATA - Air Toxics Monitors

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset includes annual (2005 - 2013) statistics of measured ambient air toxics concentrations (in micrograms per cubic meter) and associated risk estimates for...

  4. Assessment of air pollution in residential areas of Kinondoni ...

    African Journals Online (AJOL)

    The quality of the ambient air at residential areas has been assessed for Kinondoni Municipality in Dar es Salaam City. Three air pollutants namely Nitrogen dioxide (NO2), suspended particulate matter (SPM), and particulate lead (Pb) were measured in Mikocheni, Kijitonyama, Sinza, and Manzese. Saltzman, filtrations, and ...

  5. Development of a solar-powered residential air conditioner

    Science.gov (United States)

    1975-01-01

    The initial objective of the program was the optimization (in terms of cost and performance) of a Rankine cycle mechanical refrigeration system which utilizes thermal energy from a flat solar collector for air conditioning residential buildings. However, feasibility investigations of the adsorption process revealed that a dessicant-type air conditioner offers many significant advantages. As a result, limited efforts were expended toward the optimization of such a system.

  6. Challenges in assessing air pollution from residential wood combustion

    DEFF Research Database (Denmark)

    Olesen, Helge Rørdam

    2016-01-01

    The paper highlights a number of important challenges in quantifying the impact of residential wood combustion on air quality. The fact that real life emissions are controlled by the behaviour of the users makes it a challenge to determine representative emission factors. Further, in respect...... to determination of particle emissions factors, there are inconsistences between countries due to different handling of condensable gases released from wood combustion. These and other challenges are discussed in the paper....

  7. Final Recommendations of the Air Toxics Work Group

    Science.gov (United States)

    The Air Toxics Workgroup was organized under the Clean Air Act Advisory Committee for the purpose of discussing and identifying recommendations related to Urban Air Toxics. The workgroup is part of the Permits, New Source Review and Toxics Subcommittee.

  8. Mobile source air toxics mitigation measures.

    Science.gov (United States)

    2013-10-01

    In accordance with the Federal Highway Administration (FHWA) Interim Guidance Update on Mobile Source Air Toxic Analysis in NEPA Documents (September 30, 2009), transportation projects subject to the National Environmental Policy Act (NEPA) mus...

  9. Impacts of Residential Biofuel Emissions on Air Quality and Climate

    Science.gov (United States)

    Huang, Y.; Unger, N.; Harper, K.; Storelvmo, T.

    2016-12-01

    The residential biofuel sector is defined as fuelwood, agricultural residues and dung used for household cooking and heating. Aerosol emissions from this human activity play an important role affecting local, regional and global air quality, climate and public health. However, there are only few studies available that evaluate the net impacts and large uncertainties persist. Here we use the Community Atmosphere Model version 5.3 (CAM v5.3) within the Community Earth System Model version 1.2.2, to quantify the impacts of cook-stove biofuel emissions on air quality and climate. The model incorporates a novel advanced treatment of black carbon (BC) effects on mixed-phase/ice clouds. We update the global anthropogenic emission inventory in CAM v5.3 to a state-of-the-art emission inventory from the Greenhouse Gas-Air Pollution Interactions and Synergies integrated assessment model. Global in-situ and aircraft campaign observations for BC and organic carbon are used to evaluate and validate the model performance. Sensitivity simulations are employed to assess the impacts of residential biofuel emissions on regional and global direct and indirect radiative forcings in the contemporary world. We focus the analyses on several key regions including India, China and Sub-Saharan Africa.

  10. Residential air-conditioner usage in China and efficiency standardization

    International Nuclear Information System (INIS)

    Wu, Jianghong; Liu, Chaopeng; Li, Hongqi; Ouyang, Dong; Cheng, Jianhong; Wang, Yuanxia; You, Shaofang

    2017-01-01

    Determining the real energy consumption and usage pattern of a room air-conditioner (RAC) are important issues from the point of view of both RAC design and evaluation of its energy efficiency. An air-conditioner's running time is fundamental data for the calculation of SEER and APF values. Therefore, in 2010, a nationwide investigation of RAC usage was conducted and 400 selected air-conditioning-units were monitored for a full year to obtain data on their cooling and heating usage. Two running time curves (cooling and heating) were obtained for the air-conditioners as a function of outdoor air temperatures using statistical analysis. The results show that the 27–30 °C temperature range accounts for more than 52% of the cooling time. Conversely, the 0–8 °C temperature range is associated with more than 75% of the heating time. The research presented in this paper has significantly contributed to China's new variable-speed RAC efficiency standard (GB21455-2013). It also has far-reaching implications for both the air-conditioner industry and energy policy in China due to its different method of calculating energy efficiency. - Highlights: • A nationwide survey to realize China's residential air-conditions usage behaviors. • Air-conditioner running time-environment temperature curves are obtained. • The peak heating demand and peak cooling demand happen at 28 °C and 4 °C, respectively. • The temperature of 27 °C–30 °C accounts for over 52% refrigeration time. • The temperature of 0 °C–8 °C occupies more than 75% heating time.

  11. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  12. Probabilistic estimation of residential air exchange rates for ...

    Science.gov (United States)

    Residential air exchange rates (AERs) are a key determinant in the infiltration of ambient air pollution indoors. Population-based human exposure models using probabilistic approaches to estimate personal exposure to air pollutants have relied on input distributions from AER measurements. An algorithm for probabilistically estimating AER was developed based on the Lawrence Berkley National Laboratory Infiltration model utilizing housing characteristics and meteorological data with adjustment for window opening behavior. The algorithm was evaluated by comparing modeled and measured AERs in four US cities (Los Angeles, CA; Detroit, MI; Elizabeth, NJ; and Houston, TX) inputting study-specific data. The impact on the modeled AER of using publically available housing data representative of the region for each city was also assessed. Finally, modeled AER based on region-specific inputs was compared with those estimated using literature-based distributions. While modeled AERs were similar in magnitude to the measured AER they were consistently lower for all cities except Houston. AERs estimated using region-specific inputs were lower than those using study-specific inputs due to differences in window opening probabilities. The algorithm produced more spatially and temporally variable AERs compared with literature-based distributions reflecting within- and between-city differences, helping reduce error in estimates of air pollutant exposure. Published in the Journal of

  13. Development of a solar powered residential air conditioner (General optimization)

    Science.gov (United States)

    Lowen, D. J.

    1976-01-01

    A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

  14. Air toxics regulatory issues facing urban settings

    Energy Technology Data Exchange (ETDEWEB)

    Olden, K.; Guthrie, J. [National Institute of Environmental Health Sciences, Research Triangle Park, NC (United States)

    1996-10-01

    Biomarker research does not exist in isolation. Its usefulness can only be realized when it is translated into prevention strategies to protect public health. In the context of air toxics, these prevention strategies begin with the development of regulatory standards derived from risk assessment schemes. The Clean Air Act Amendments of 1990 list 189 air toxics, including many volatile organics, metals, and pesticides. The National Institute of Environmental Health Sciences (NIEHS), through its affiliation with the National Toxicology Program, has generated toxicity and carcinogenicity data on more than 100 of these air toxics. The NIEHS extramural and intramural research portfolios support a variety of projects that develop and validate biomarkers for use in environmental health science and risk assessment. Biomarkers have a tremendous potential in the areas of regulating air toxics and protecting public health. Risk assessors need data provided by biomarkers of exposure, biomarkers of close/pharmacokinetics, biomarkers of susceptibility or individual variability, and biomarkers of effects. The greatest benefit would be realized if biomarkers could be employed in four areas of primary and secondary prevention. The first is the use of biomarkers to enhance extrapolation of animal data to human exposure situations in establishing risk standards. The second is the use of biomarkers that assess noncancer, as well as cancer, end points. Important health end points include pulmonary dysfunction, immunotoxicity, and neurotoxicity. Third, biomarkers that serve as early warning signs to detect intermediate effects would enhance our ability to design timely and cost-effective intervention strategies. Finally, biomarkers used to evaluate the effectiveness of intervention strategies both in clinical and regulatory settings, would enable us to ensure that programs designed to protect public health do, in fact, achieve the desired outcome. 9 refs., 2 tabs.

  15. Secondary air systems for improved residential wood stove combustion

    Energy Technology Data Exchange (ETDEWEB)

    Poirot, R.L.; Sanborn, C.R.

    1982-12-21

    Three wood burning stoves were modified by the addition of preheated secondary air systems to keep burn volatile gases given off during the initial stage of combustion. This report describes the modifications and the performance of the stoves after modification. Stoves tested during the year's study included a Jotul 118, a Garrison IV and a Hearthstone I. After modification, total particulate emissions decreased in the three stoves by 56%, 69% and 4%, respectively. Flue gas CO/sub 2/ (a by-product of combustion and an indicator of the completeness of combustion) increased by 15%, 15% and 17%, respectively. Temperatures in the secondary combustion zones increased by 17%, 50% and 6%. On the basis of these measurements, other internal temperatures and visual observations, we believe the modifications significantly increased the combustion efficiencies of the Jotul and the Garrison. No improvement was discerned in the Hearthstone's performance (possibly due to unrealistic burn rate compared to firebox size). The design concepts developed, refined and tested under this year's study should be readily applicable to the majority of residential wood stoves on the market.

  16. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  17. Probabilistic estimation of residential air exchange rates for population-based human exposure modeling

    Science.gov (United States)

    Residential air exchange rates (AERs) are a key determinant in the infiltration of ambient air pollution indoors. Population-based human exposure models using probabilistic approaches to estimate personal exposure to air pollutants have relied on input distributions from AER meas...

  18. Managing air toxics under the new Clean Air Act Amendments

    International Nuclear Information System (INIS)

    Chow, W.; Miller, M.J.; Fortune, J.; Behrens, G.; Rubin, E.

    1991-01-01

    The U.S. Environmental Protection Agency (EPA) has been regulating air toxics (hazardous air pollutants) under Section 112 of the 1970 Clean Air Act Amendments. To date, EPA has established emission standards for seven hazardous air pollutants. They include arsenic, asbestos, benzene, beryllium, mercury, vinyl chloride and radionuclides. EPA had determined that the low risks associated with electric utility fossil fuel power plant radionuclide emissions did not justify regulation under Section 112. The Clean Air Act Amendments of 1990 greatly expand EPA's rulemaking authority over toxic or hazardous air pollutants. The law lists 189 chemicals that would be subject to control. Sources that emit 10 tons/yr or more of any one pollutant, or 25 tons/yr or more of any combination thereof, must apply maximum available control technology (MACT). By definition, MACT is at least as stringent as best available control technology (BACT) for similar sources. However, consideration of the cost and feasibility of control, energy impacts and environmental factors will be given in MACT. Under the new amendments, the EPA will conduct a three-year study of the public health hazards from exposure to toxic emissions from utilities and report to Congress. EPA can regulate such emissions only if the regulations are appropriate based on this study. Two additional studies addressing mercury are also required. The first directs the EPA to conduct a four-year study of mercury emissions from electric utility steam generating units, municipal waste combustion units, and other sources. Included in this paper are evaluations of the rate and mass of such emissions, of health and environmental effects, and of the available control technologies and their costs

  19. Price freezes, durables and residential electricity demand - Evidence from the Greater Buenos Aires

    Energy Technology Data Exchange (ETDEWEB)

    Casarin, Ariel; Delfino, Maria Eugenia

    2010-09-15

    This paper examines the determinants of residential electricity demand in the Greater Buenos Aires between 1997 and 2006. During the second half of this period, residential tariffs remained nominally fixed, while an income boom boosted up the sales of durables. This study differs from previous works in that it explicitly considers the impact of the stock of air-conditioners on residential demand. The paper reports short- and long-run elasticities and examines the contribution of prices and durables to recent demand growth. Simulations illustrate the impact of prices and durables on future demand.

  20. Air toxics emissions from an IGCC process

    Energy Technology Data Exchange (ETDEWEB)

    Mojtahedi, W.; Norrbacka, P. [Enviropower Inc., Espoo (Finland); Hinderson, A. [Vattenfall (Sweden); Rosenberg, R.; Zilliacus, R.; Kurkela, E.; Nieminen, M. [VTT Energy, Espoo (Finland); Hoffren, H. [IVO International Oy, Vantaa (Finland)

    1996-12-01

    The so-called simplified coal gasification combined cycle process, incorporating air gasification and hot gas cleanup, promises high power generation efficiency in an environmentally acceptable manner. Increasingly more stringent environmental regulations have focused attention on the emissions of not only SO{sub 2} and NO{sub x} but also on the so-called air toxics which include a number of toxic trace elements. As result of recent amendments to the United States Clean Air Act, IGCC emissions of eleven trace elements: antimony, arsenic, beryllium, cadmium, chromium, cobalt, lead, manganese, mercury, nickel, selenium - as well as the radionuclides uranium and thorium may be regulated. Similarly, air missions standards in Europe include a limit of 0.05 mg Nm{sup 3} for mercury and cadmium and 1.0 3/Nm{sup 3} for other class I trace elements. A suitable sampling/measuring system has been developed in this project (in cooperation with Imatran Voima Oy, Electric Power Research Institute (EPRI) and Radian Cooperation) which will be used in the pressurized gasification tests. This will enable an accurate measurement of the volatilized trace element species, at high temperature and pressure, which may be found in the vapour phase. Models are being developed that can be used to determine not only the chemical equilibrium composition of gaseous, liquid and solid phases, but also possible interactions of the gaseous species with aerosol particles and surfaces, These should be used to more accurately assess the impact of the toxic trace metals emitted from the simplified IGCC system

  1. Residential Pre-Cooling: Mechanical Cooling and Air-Side Economizers:

    OpenAIRE

    Turner, William J.N; Walker, Iain S.; Roux, Jordan

    2012-01-01

    This study used an advanced airflow, energy and humidity modeling tool to evaluate residential air-side economizers and mechanical pre-cooling strategies using the air conditioner, in all US DOE Climate Zones for a typical new home with ASHRAE Standard 62.2 compliant ventilation. A residential air-side economizer is a large supply fan used for night ventilation. Mechanical pre-cooling used the building air conditioner operating at lower than usual set before the peak demand period. The simula...

  2. Proposed residential indoor air quality guidelines for formaldehyde

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, N.

    2005-07-01

    This paper proposed a set of revised residential indoor air quality guidelines for formaldehyde. In the earlier guidelines, target and action levels were set at 60 {mu}g/m{sup 3} and 120 {mu}g/. However, epidemiological studies on the effects of chronic formaldehyde exposure have consistently found respiratory and allergic effects at levels below 123 {mu}g/m{sup 3}. Formaldehyde levels in home have been associated with increased risk of atopy and have also been associated with the hospitalization of children. Summaries of various epidemiological studies were presented. A summary of critical effects and the derivation of the guidelines was provided. Based on clinical studies and animal experiments, the primary effects of acute exposure to formaldehyde are the irritation of the mucosa of the upper respiratory tract and the eyes. The no observable adverse effects level (NOAEL) and lowest observable adverse effects level (LOAEL) for this outcome are 615 and 1,230 {mu}g/m{sup 3}. It was noted that an association between low-level exposure to formaldehyde and the development of allergic sensitization and asthma is biologically plausible as it is consistent with observations in animals. It was concluded that short-term exposure to formaldehyde should be limited to 123{mu}g/m{sup 3}. It was recommended that long term exposure to formaldehyde be limited to 50 {mu}g/m{sup 3}. Although formaldehyde is carcinogenic to humans, the cancer risk associated with lifelong exposure at the recommended levels is estimated to be negligible. 73 refs., 9 tabs.

  3. NATIONAL-SCALE ASSESSMENT OF AIR TOXICS RISKS ...

    Science.gov (United States)

    The national-scale assessment of air toxics risks is a modeling assessment which combines emission inventory development, atmospheric fate and transport modeling, exposure modeling, and risk assessment to characterize the risk associated with inhaling air toxics from outdoor sources. This national-scale effort will be initiated for the base year 1996 and repeated every three years thereafter to track trends and inform program development. Provide broad-scale understanding of inhalation risks for a subset of atmospherically-emitted air toxics to inform further data-gathering efforts and priority-setting for the EPA's Air Toxics Programs.

  4. Controlling air toxics through advanced coal preparation

    Energy Technology Data Exchange (ETDEWEB)

    Straszheim, W.E.; Buttermore, W.H.; Pollard, J.L. [Iowa State Univ., Ames, IA (United States)

    1995-11-01

    This project involves the assessment of advanced coal preparation methods for removing trace elements from coal to reduce the potential for air toxic emissions upon combustion. Scanning electron microscopy-based automated image analysis (SEM-AIA) and advanced washability analyses are being applied with state-of-the-art analytical procedures to predict the removal of elements of concern by advanced column flotation and to confirm the effectiveness of preparation on the quality of quantity of clean coal produced. Specific objectives are to maintain an acceptable recovery of combustible product, while improving the rejection of mineral-associated trace elements. Current work has focused on determining conditions for controlling column flotation system across its operating range and on selection and analysis of samples for determining trace element cleanability.

  5. Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

    Science.gov (United States)

    1978-01-01

    A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  6. Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  7. Rational use of supply air in residential buildings

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Svendsen, Svend

    2009-01-01

    The ventilation rate influences the air quality by determining the intensity of pollution sources. This paper compared the intensity of the sensory pollution during occupied hours in an apartment ventilated by a constant air volume system and demand controlled ventilation systems controlled...... by occupancy. The systems supplied the same total volume of air daily. It was found that the supply air could be used more rationally by redistributing it according to occupancy compared to maintaining a constant ventilation rate during all hours....

  8. Potentially toxic concentrations of synthetic pyrethroids associated with low density residential land use

    Directory of Open Access Journals (Sweden)

    Stephen Marshall

    2016-11-01

    Full Text Available Trace organic compounds associated with human activity are now ubiquitous in the environment. As the population becomes more urbanised and the use of pesticides and person care products continues to increase, urban waterways are likely to receive higher loads of trace organic contaminants with unknown ecological consequences. To establish the extent of trace organic contamination in urban runoff, concentrations of emerging chemicals of concern were determined in sediments from 99 urban wetlands in and around Melbourne, Australia between February and April, 2015. As a preliminary estimation of potential risks to aquatic biota, we compared measured concentrations with thresholds for acute and chronic toxicity, and modelled toxic units as a function of demographic and land use trends. The synthetic pyrethroid insecticide bifenthrin was common and widespread, and frequently occurred at concentrations likely to cause toxicity to aquatic life. Personal care products DEET and triclosan were common and widely distributed, while the herbicides diuron and prometryn, and the fungicides pyrimethanil and trifloxystrobin occurred less frequently. Toxic unit modelling using random forests found complex and unexpected associations between urban land uses and trace organic concentrations. Synthetic pyrethroid insecticides were identified as emerging compounds of concern, particularly bifenthrin. In contrast with previous surveys, the highest bifenthrin concentrations were associated with lower housing and population density, implicating low-density residential land use in bifenthrin contamination. We discuss the implications for pesticide regulation and urban wetland management in a global context.

  9. IEA Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    with heat recovery systems, one of the next focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or to make it in a new way demand controlled. However, this must be done such that it has no have adverse effects...... on Indoor Air Quality (IAQ). Annex 68, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy...... the hygrothermal parameters, the chemical conditions, ventilation and the wellbeing of occupants. A flagship outcome of the project is anticipated to be a guidebook on design and operation of ventilation in residential buildings to achieve high IAQ with smallest possible energy consumption....

  10. An International Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or making it in a new way demand controlled. However, this must be done such that it does not have adverse effects on indoor air quality (IAQ). Annex 68......, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy performance whilst providing...... studies. A flagship outcome of the project will be a guidebook on design and operation of ventilation in residential buildings to achieve high IAQ with least possible energy consumption. The paper illustrates the working program of each of these activities....

  11. Air toxics emission from an IGCC process

    Energy Technology Data Exchange (ETDEWEB)

    Mojtahedi, W.; Hovath, A. [Carbona Inc, Helsinki (Finland); Hinderson, A. [Vattenfall Utveckling (Sweden); Nykaenen, J.; Hoffren, H. [Imatran Voima Oy, Vantaa (Finland); Nieminen, M.; Kurkela, E. [VTT, Espoo (Finland)

    1997-10-01

    The emissions of 12 toxic trace element from a coal-fired IGCC plant were calculated based on thermodynamic equilibrium in the gas phase and some of the results published. The theoretical calculations were extended to include some other fuels as well as mixture of some of these fuels. The combustion of the product gas in the gas turbine is also considered. These simulations correspond to gasification of the fuel at 850-1050 deg C (depending on the fuel) and 1823 bar pressure. The gas composition was taken from the measured data as far as possible. In the absence of experimental data, a computer code developed for the U-Gas gasifier was used to determine the fuel gas composition. The gas was then cooled to 550 deg C in the gas cooler and filtered at this same temperature and burned in the gas turbine with an air ratio of 3.2. The results of these simulations are compared with the measured data of an experimental program designed to measure the emissions of a few selected trace elements from a 15 MW,h pressurized fluidized bed gasification pilot plant. The pilot plant was equipped with an advanced hot gas cleanup train which includes a two fluidized-bed reactor system for high-temperature, high-pressure external sulfur removal and a filtration unit housing porous, rigid ceramic candle filters. The trace element concentrations in the fuel, bottom ash, and filter ash are determined and the results compared with EPA regulatory levels

  12. Development of a solar-powered residential air conditioner. Program review

    Science.gov (United States)

    1975-01-01

    Progress in the effort to develop a residential solar-powered air conditioning system is reported. The topics covered include the objectives, scope and status of the program. The results of state-of-art, design, and economic studies and component and system data are also presented.

  13. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kruis, N. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brandemuehl, M. [Univ. of Colorado, Boulder, CO (United States)

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost-effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  14. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    removal effectiveness (CRE) and local air change index was measured in order to characterize ventilation effectiveness in the occupied zone. Acceptable thermal comfort was found in most experiments; however, air temperature differences higher than 3 °C occurred when floor cooling was combined...

  15. Indoor air mycoflora of residential dwellings in Jos metropolis ...

    African Journals Online (AJOL)

    Background: The quality of air in the environment where one lives or works can have potential effects on human health. There are strong indications that in many parts of the world, our homes, schools and workplaces are heavily contaminated with air-borne molds and other biological contaminants. Objectives: This study ...

  16. Managing air toxics: Status of EPRI's PISCES project

    International Nuclear Information System (INIS)

    Chow, W.; Levin, L.; Miller, M.

    1992-01-01

    The US Environmental Protection Agency (EPA) has historically regulated air toxics (hazardous air pollutants) under Section 112 of the Clean Air Act. To date, EPA has established emission standards for 8 hazardous air pollutants (arsenic, asbestos, benzene, beryllium, mercury, radionuclides, coke oven emissions and vinyl chloride). The US electric utility industry was not determined to be a source category requiring regulation for any of the eight chemicals. Of the eight, radionuclides were the last species for which EPA established hazardous emissions standards. In this instance, EPA determined that the risks associated with electric utility fossil fuel power plant emissions were sufficiently low that they should not be regulated. However, the 1990 Clean Air Act Amendments require a new evaluation of the electric utility industry emissions of hazardous air pollutants (1). This paper summarizes the key features of the air toxics provisions of the Clean Air Act Amendments, describes EPRI's activities on the subject, and provides some preliminary insights from EPRI's research to date

  17. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M. [Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, University of Vigo, Campus Lagoas-Marcosende No. 9, 36310 Vigo (Spain)

    2011-01-15

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper. (author)

  18. Residential Central Air Conditioning and Heat Pump Installation – Workshop Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Burlington, MA (United States); Young, Jim [Navigant Consulting, Burlington, MA (United States); Bargach, Youssef [Navigant Consulting, Burlington, MA (United States)

    2016-11-01

    DOE's Building Technologies Office works with researchers and industry partners to develop and deploy technologies that can substantially reduce energy consumption in residential and commercial buildings. This report aims to advance BTO’s energy savings, emissions reduction, and other program goals by identifying research and development (R&D), demonstration and deployment, and other non-regulatory initiatives for improving the design and installation of residential central air conditioners (CAC) and central heat pumps (CHP). Improving the adoption of CAC/CHP design and installation best practices has significant potential to reduce equipment costs, improve indoor air quality and comfort, improve system performance, and most importantly, reduce household energy consumption and costs for heating and cooling by addressing a variety of common installation issues.

  19. Effects of an ozone-generating air purifier on indoor secondary particles in three residential dwellings.

    Science.gov (United States)

    Hubbard, H F; Coleman, B K; Sarwar, G; Corsi, R L

    2005-12-01

    The use of indoor ozone generators as air purifiers has steadily increased over the past decade. Many ozone generators are marketed to consumers for their ability to eliminate odors and microbial agents and to improve health. In addition to the harmful effects of ozone, recent studies have shown that heterogeneous and homogeneous reactions between ozone and some unsaturated hydrocarbons can be an important source of indoor secondary pollutants, including free radicals, carbonyls, carboxylic acids, and fine particles. Experiments were conducted in one apartment and two detached single-family dwellings in Austin, TX, to assess the effects of an ozone generator on indoor secondary organic aerosol concentrations in actual residential settings. Ozone was generated using a commercial ozone generator marketed as an air purifier, and particle measurements were recorded before, during, and after the release of terpenes from a pine oil-based cleaning product. Particle number concentration, ozone concentration, and air exchange rate were measured during each experiment. Particle number and mass concentrations increased when both terpenes and ozone were present at elevated levels. Experimental results indicate that ozone generators in the presence of terpene sources facilitate the growth of indoor fine particles in residential indoor atmospheres. Human exposure to secondary organic particles can be reduced by minimizing the intentional release of ozone, particularly in the presence of terpene sources. Past studies have shown that ozone-initiated indoor chemistry can lead to elevated concentrations of fine particulate matter, but have generally been completed in controlled laboratory environments and office buildings. We explored the effects of an explicit ozone generator marketed as an air purifier on the formation of secondary organic aerosol mass in actual residential indoor settings. Results indicate significant increases in number and mass concentrations for particles

  20. Residential Air Pollution, Road Traffic, Greenness and Maternal Hypertension: Results from GINIplus and LISAplus.

    Science.gov (United States)

    Jendrossek, Mario; Standl, Marie; Koletzko, Sibylle; Lehmann, Irina; Bauer, Carl-Peter; Schikowski, Tamara; von Berg, Andrea; Berdel, Dietrich; Heinrich, Joachim; Markevych, Iana

    2017-07-01

    The public health burden of hypertension is high, but its relationship with long-term residential air pollution, road traffic, and greenness remains unclear. To investigate associations between residential air pollution, traffic, greenness, and hypertension among mothers. Information on doctor-diagnosed maternal hypertension was collected at the 15-year follow-up of two large population-based multicenter German birth cohorts-GINIplus and LISAplus (n=3063). Residential air pollution was modelled by land use regression models within the ESCAPE and universal kriging within the APMoSPHERE projects. Road traffic was defined as traffic load on major roads within a 100-m buffer around residences. Vegetation level ( ie , greenness) was defined as the mean Normalized Difference Vegetation Index in a 500-m buffer around residences and was assessed from Landsat 5 TM satellite images. All the exposure variables were averaged over three residential addresses during the last 10 years and categorized into tertiles or dichotomized. The individual associations between each of the exposure variables and hypertension were assessed using logistic regression analysis. No significant and consistent associations across different levels of adjustment were observed between the exposures of interest and hypertension. The only significant estimate was found with coarse particulate matter concentrations (OR 1.66, 95% CI 1.01 to 2.74; 3 rd vs 1 st tertile) among mothers residing in the Wesel area. No significant associations were observed with traffic load or greenness. This study does not provide evidence on detrimental effects of air pollution and road traffic or beneficial effects of greenness on hypertension among German adults.

  1. Towards a Residential Air-Conditioner Usage Model for Australia

    Directory of Open Access Journals (Sweden)

    Mark Goldsworthy

    2017-08-01

    Full Text Available Realistic models of occupant behaviour in relation to air-conditioner (a/c use are fundamentally important for developing accurate building energy simulation tools. In Australia and elsewhere, such simulation tools are inextricably bound both in legislation and in the design of new technology, electricity infrastructure and regulatory schemes. An increasing number of studies in the literature confirm just how important occupants are in determining overall energy consumption, but obtaining the data on which to build behaviour models is a non-trivial task. Here data is presented on air-conditioner usage derived from three different types of case study analyses. These are: (i use of aggregate energy consumption data coupled with weather, demographic and building statistics across Australia to estimate key predictors of energy use at the aggregate level; (ii use of survey data to determine characteristic a/c switch on/off behaviours and usage frequencies; and (iii use of detailed household level sub-circuit monitoring from 140 households to determine a/c switch on/off probabilities and their dependence on different building and occupant parameters. These case studies are used to assess the difficulties associated with translation of different forms of individual, aggregate and survey based information into a/c behaviour simulation models. Finally a method of linking the data gathering methodologies with the model development is suggested. This method would combine whole-of-house “smart”-meter data measurements with linked targeted occupant surveying.

  2. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  3. Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-06-01

    Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr-1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 μg/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 μg/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

  4. The effect of an ion generator on indoor air quality in a residential room.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2011-08-01

    Ion generators charge particles with a corona prior to their removal on collector plates or indoor surfaces and also emit ozone, which can react with terpenes to yield secondary organic aerosol, carbonyls, carboxylic acids, and free radicals. This study characterized the indoor air quality implications of operating an ion generator in a 27 m(3) residential room, with four different test room configurations. Two room configurations had carpet overlaying the original flooring of stained/sealed concrete, and for one configuration with and without carpet, a plug-in air freshener was used as a terpene source. Measurements included airborne sampling of particulate matter (0.015-20 μm), terpenes and C(1) -C(4) and C(6) -C(10) aldehydes, ozone concentrations, and air exchange rates. When the heating, ventilating, and air-conditioning system was not operating (room air exchange rate = ∼0.5/h), the use of the ion generator in the presence of the air freshener led to a net increase in ultrafine particles (ozone were observed regardless of air freshener presence, as well as increases in formaldehyde and nonanal, albeit within measurement uncertainty in some cases. Thus, it may be prudent to limit ion generator use indoors until evidence of safety can be ascertained. Portable ion generators are intended to clean the air of particles, but they may emit ozone as a byproduct of their operation, which has the potential to degrade indoor air quality. This study showed that under certain conditions in a residential room, the use of a portable ion generator can increase concentrations of ozone and, to a lesser degree, potentially aldehydes. Also, if operated in the presence of a plug-in air freshener that emits terpenes, its use can increase concentrations of secondary organic aerosol in the ultrafine size range. © 2010 John Wiley & Sons A/S.

  5. Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia

    DEFF Research Database (Denmark)

    Földváry, Veronika; Bekö, Gabriel; Langer, Sarka

    2017-01-01

    efficiency of these buildings rarely consider their impact on the indoor air quality (IAQ). The objective of the present study was to evaluate the impact of simple energy renovation on IAQ, air exchange rates (AER) and occupant satisfaction in Slovak residential buildings. Three pairs of identical naturally...... of nitrogen dioxide (NO2), formaldehyde and total and individual volatile organic compounds (VOC) were also measured. CO2 concentrations were significantly higher and AERs were lower in the renovated buildings. Formaldehyde concentrations increased after renovation and were positively correlated with CO2...

  6. Thermal oxidation for air toxics control

    International Nuclear Information System (INIS)

    Pennington, R.L.

    1991-01-01

    The Administration projects annual expenditures of $1.1 billion by 1995, increasing to $6.7 billion by 2005, in order to comply with the new Clean Air Act Title III hazardous air pollutant requirements. The Title III requirements include 189 hazardous air pollutants which must be reduced or eliminated by 2003. Twenty of the 189 listed pollutants account for approximately 75 percent of all hazardous air pollutant emissions. Ninety percent of these 20 pollutants can be effectively controlled through one or mote of the thermal oxidation technologies. This paper reports that the advantages and disadvantages of each thermal oxidation technology vary substantially and must be reviewed for each application in order to establish the most effective thermal oxidation solution. Effective thermal oxidation will meet MACT (maximum achievable control technology) emission standards

  7. Preventive Effect of Residential Green Space on Infantile Atopic Dermatitis Associated with Prenatal Air Pollution Exposure.

    Science.gov (United States)

    Lee, Ji-Young; Lamichhane, Dirga Kumar; Lee, Myeongjee; Ye, Shinhee; Kwon, Jung-Hyun; Park, Myung-Sook; Kim, Hwan-Cheol; Leem, Jong-Han; Hong, Yun-Chul; Kim, Yangho; Ha, Mina; Ha, Eunhee

    2018-01-09

    Few birth cohort studies have examined the role of traffic-related air pollution (TRAP) in the development of infantile atopic dermatitis (AD), but none have investigated the role of preventive factors such as green spaces. The aim of this study was to investigate whether exposure to nitrogen dioxide (NO₂) and particulate matter with an aerodynamic diameter of Health study. Subjects were geocoded to their residential addresses and matched with air pollution data modeled using land-use regression. Information on infantile AD was obtained by using a questionnaire administered to the parents or guardians of the children. The association between infantile AD and exposure to NO₂ and PM 10 was determined using logistic regression models. We assessed the effects of residential green spaces using stratified analyses and by entering product terms into the logistic regression models. The risk of infantile AD significantly increased with an increase in air pollution exposure during the first trimester of pregnancy. The adjusted odds ratio (OR) and 95% confidence interval (CI) were 1.219 (1.023-1.452) per 10 μg/m³ increase in PM 10 and 1.353 (1.027-1.782) per 10 ppb increase in NO₂. An increase in the green space within 200 m of residence was associated with a decreased risk of AD (OR = 0.996, 95% CI: 0.993-0.999). The stratified analysis of residential green space revealed stronger associations between infantile AD and PM 10 and NO₂ exposure during the first trimester in the areas in the lower tertiles of green space. This study indicated that exposure to TRAP during the first trimester of pregnancy is associated with infantile AD. Less residential green space may intensify the association between TRAP exposure and infantile AD.

  8. Residential exposure to traffic-related air pollution and survival after heart failure.

    Science.gov (United States)

    Medina-Ramón, Mercedes; Goldberg, Robert; Melly, Steven; Mittleman, Murray A; Schwartz, Joel

    2008-04-01

    Although patients with heart failure (HF) have been identified as particularly susceptible to the acute effects of air pollution, the effects of long-term exposure to air pollution on patients with this increasingly prevalent disease are largely unknown. This study was designed to examine the mortality risk associated with residential exposure to traffic-related air pollution among HF patients. A total of 1,389 patients hospitalized with acute HF in greater Worcester, Massachusetts, during 2000 were followed for survival through December 2005. We used daily traffic within 100 and 300 m of residence as well as the distance from residence to major roadways and to bus routes as proxies for residential exposure to traffic-related air pollution. We assessed mortality risks for each exposure variable using Cox proportional hazards models adjusted for prognostic factors. After the 5-year follow-up, only 334 (24%) subjects were still alive. An interquartile range increase in daily traffic within 100 m of home was associated with a mortality hazard ratio (HR) of 1.15 [95% confidence interval (CI), 1.05-1.25], whereas for traffic within 300 m this association was 1.09 (95% CI, 1.01-1.19). The mortality risk decreased with increasing distance to bus routes (HR = 0.88; 95% CI, 0.81-0.96) and was larger for those living within 100 m of a major roadway or 50 m of a bus route (HR = 1.30; 95% CI, 1.13-1.49). Adjustment for area-based income and educational level slightly attenuated these associations. Residential exposure to traffic-related air pollution increases the mortality risk after hospitalization with acute HF. Reducing exposure to traffic-related emissions may improve the long-term prognosis of HF patients.

  9. SNRB{trademark} air toxics monitoring. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    Babcock & Wilcox (B&W) is currently conducting a project under the DOE`s Clean Coal Technology (CCT II) Program to demonstrate its SO{sub x}NO{sub x}-Rox Box{trademark} (SNRB{trademark}) process in a 5 MWe Field Demonstration Unit at Ohio Edison`s R. E. Burger Plant near Shadyside, Ohio. The objective of the SNRB{trademark} Air Toxics Monitoring Project was to provide data on SNRB{trademark} air toxics emissions control performance to B&W and to add to the DOE/EPRI/EPA data base by quantifying the flow rates of selected hazardous substances (or air toxics) in all of the major input and output streams of the SNRB{trademark} process as well as the power plant. Work under the project included the collection and analysis of representative samples of all major input and output streams of the SNRB{trademark} demonstration unit and the power plant, and the subsequent laboratory analysis of these samples to determine the partitioning of the hazardous substances between the various process streams. Material balances for selected air toxics were subsequently calculated around the SNRB{trademark} and host boiler systems, including the removal efficiencies across each of the major air pollution control devices. This report presents results of the SNRB{trademark} Air Toxics Monitoring Project. In addition to the Introduction, a brief description of the test site, including the Boiler No. 8 and the SNRB{trademark} process, is included in Section H. The concentrations of air toxic emissions are presented in Section II according to compound class. Material balances are included in Section IV for three major systems: boiler, electrostatic precipitator, and SNRB{trademark}. Emission factors and removal efficiencies are also presented according to compound class in Sections V and VI, respectively. A data evaluation is provided in Section VII.

  10. Monitoring the levels of toxic air pollutants in the ambient air of ...

    African Journals Online (AJOL)

    user

    The ambient air quality in Freetown, Sierra Leone was investigated for the first time for toxic air pollutants. We investigated the levels of polycyclic aromatic hydrocarbons (PAHs), suspended particulate matter (SPM) and carbon monoxide (CO) and considered the implication of air quality and health risks. Particulate samples ...

  11. Development of residential-conservation-survey methodology for the US Air Force. Interim report. Task two

    Energy Technology Data Exchange (ETDEWEB)

    Abrams, D. W.; Hartman, T. L.; Lau, A. S.

    1981-11-13

    A US Air Force (USAF) Residential Energy Conservation Methodology was developed to compare USAF needs and available data to the procedures of the Residential Conservation Service (RCS) program as developed for general use by utility companies serving civilian customers. Attention was given to the data implications related to group housing, climatic data requirements, life-cycle cost analysis, energy saving modifications beyond those covered by RCS, and methods for utilizing existing energy consumption data in approaching the USAF survey program. Detailed information and summaries are given on the five subtasks of the program. Energy conservation alternatives are listed and the basic analysis techniques to be used in evaluating their thermal performane are described. (MCW)

  12. Preventive Effect of Residential Green Space on Infantile Atopic Dermatitis Associated with Prenatal Air Pollution Exposure

    Directory of Open Access Journals (Sweden)

    Ji-Young Lee

    2018-01-01

    Full Text Available Few birth cohort studies have examined the role of traffic-related air pollution (TRAP in the development of infantile atopic dermatitis (AD, but none have investigated the role of preventive factors such as green spaces. The aim of this study was to investigate whether exposure to nitrogen dioxide (NO2 and particulate matter with an aerodynamic diameter of <10 μm (PM10 during pregnancy is associated with increased risk of development of AD in 6-month-old children and also to examine how this association changes with residential green space. This study used prospective data from 659 participants of the Mothers and Children’s Environmental Health study. Subjects were geocoded to their residential addresses and matched with air pollution data modeled using land-use regression. Information on infantile AD was obtained by using a questionnaire administered to the parents or guardians of the children. The association between infantile AD and exposure to NO2 and PM10 was determined using logistic regression models. We assessed the effects of residential green spaces using stratified analyses and by entering product terms into the logistic regression models. The risk of infantile AD significantly increased with an increase in air pollution exposure during the first trimester of pregnancy. The adjusted odds ratio (OR and 95% confidence interval (CI were 1.219 (1.023–1.452 per 10 μg/m3 increase in PM10 and 1.353 (1.027–1.782 per 10 ppb increase in NO2. An increase in the green space within 200 m of residence was associated with a decreased risk of AD (OR = 0.996, 95% CI: 0.993–0.999. The stratified analysis of residential green space revealed stronger associations between infantile AD and PM10 and NO2 exposure during the first trimester in the areas in the lower tertiles of green space. This study indicated that exposure to TRAP during the first trimester of pregnancy is associated with infantile AD. Less residential green space may intensify

  13. Air toxics and the 1990 Clean Air Act: Managing trace element emissions

    International Nuclear Information System (INIS)

    Chow, W.; Levin, L.; Miller, M.J.

    1992-01-01

    The US Environmental Protection Agency (EPA) has historically regulated air toxics (hazardous air pollutants) under Section 112 of the Clean Air Act. To date, EPA has established emission standards for 8 hazardous air pollutants (arsenic, asbestos, benzene, beryllium, mercury, radionuclides, coke oven emissions and vinyl chloride). The US electric utility industry was not determined to be a source category requiring regulation for any of the eight chemicals. Of the eight, radionuclides were the last species for which EPA established hazardous emissions standards. In this instance, EPA determined that the risks associated with electric utility fossil fuel power plant emissions were sufficiently low that they should not be regulated. However, the 1990 Clean Air Act Amendments require a new evaluation of the electric utility industry emissions of hazardous air pollutants. This paper summarizes the key features of the air toxics provisions of the Clean Air Act Amendments, describes EPRI's activities on the subject, and provides some preliminary insights from EPRI's research to date

  14. National Air Toxics Assessment - 2002, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  15. National Air Toxics Assessment - 1999, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  16. National Air Toxics Assessment - 2005, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  17. The effects of aircraft noise at Williams Air Force Base Auxiliary Field on residential property values

    Energy Technology Data Exchange (ETDEWEB)

    Morey, M.J.

    1990-11-01

    This report considers the environmental consequences of moving the flight training operations of the US Air Force's 82nd Flying Training Wing from the auxiliary airfield, Coolidge-Florence Municipal Airport (CFMA), to a more remote location in Pinal County, Arizona. It examines how actual noise from touch-and-go flights of T-37 aircraft and perceived (anticipated) noise affect the market value of residential property near CFMA. Noise, measured by a noise index, is correlated with market values through a regression analysis applied to a hedonic price model of the Coolidge-Florence housing market. Prices and characteristics of 42 residential properties sold in 1987 and 1988 were used to estimate a perceived noise effect. The report finds that the coefficient on the measure of perceived noise, based on the noise exposure forecast (NEF) index, is statistically insignificant, even though the sign and value are consistent with those estimated in other studies. It concludes that current flights do not have a significant effect on residential property values, partially because there is no housing near CFMA. This and larger studies indicate that flight operations at a new auxiliary airfield would not affect property values if runways were at least 12,000 feet away from housing. 12 refs., 2 tabs.

  18. Performance of residential air-conditioning systems with flow maldistribution in fin-and-tube evaporators

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian

    2011-01-01

    Refrigerant and airflow maldistribution in fin-and-tube evaporators for residential air-conditioning was investigated with numerical modeling. Fin-and-tube heat exchangers usually have a pre-defined circuitry. However, the objective in this study was to perform a generic investigation of each...... in this paper. The maldistribution sources of interest were: inlet liquid/vapor phase distribution, feeder tube bending and airflow distribution. The results show that maldistribution reduced the cooling capacity and the coefficient of performance of the system. In particular, different phase distribution...

  19. AIR TOXICS EMISSIONS FROM A VINYL SHOWER CURTAIN

    Science.gov (United States)

    The paper reports results of both static and dynamic chamber tests conducted to evaluate emission characteristics of air toxics from a vinyl shower Curtain. (NOTE: Due to the relatively low price and ease of installation, vinyl shower curtains have been widely used in bathrooms i...

  20. Polycyclic Aromatic Hydrocarbons in Air and their Toxic Potency

    Indian Academy of Sciences (India)

    GENERAL I ARTICLE. Polycyclic Aromatic Hydrocarbons in Air and their Toxic Potency. R Mohanraj is currently working as Senior Research. Fellow in Environmental. Impact Assessment (EIA). Division of Salim Ali Centre for Ornithology and Natural. History (SACON),. Coimbatore. His primary interest lies in aerosol.

  1. More than clean air and tranquillity: Residential green is independently associated with decreasing mortality.

    Science.gov (United States)

    Vienneau, Danielle; de Hoogh, Kees; Faeh, David; Kaufmann, Marco; Wunderli, Jean Marc; Röösli, Martin

    2017-11-01

    Green space may improve health by enabling physical activity and recovery from stress or by decreased pollution levels. We investigated the association between residential green (greenness or green space) and mortality in adults using the Swiss National Cohort (SNC) by mutually considering air pollution and transportation noise exposure. To reflect residential green at the address level, two different metrics were derived: normalised difference vegetation index (NDVI) for greenness, and high resolution land use classification data to identify green spaces (LU-green). We used stratified Cox proportional hazard models (stratified by sex) to study the association between exposure and all natural cause mortality, respiratory and cardiovascular disease (CVD), including ischemic heart disease, stroke and hypertension related mortality. Models were adjusted for civil status, job position, education, neighbourhood socio-economic position (SEP), geographic region, area type, altitude, air pollution (PM 10 ), and transportation noise. From the nation-wide SNC, 4.2 million adults were included providing 7.8years of follow-up and respectively 363,553, 85,314 and 232,322 natural cause, respiratory and CVD deaths. Hazard ratios (and 95%-confidence intervals) for NDVI [and LU-green] per interquartile range within 500m of residence were highly comparable: 0.94 (0.93-0.95) [0.94 (0.93-0.95)] for natural causes; 0.92 (0.91-0.94) [0.92 (0.90-0.95)] for respiratory; and 0.95 (0.94-0.96) [0.96 (0.95-0.98)] for CVD mortality. Protective effects were stronger in younger individuals and in women and, for most outcomes, in urban (vs. rural) and in the highest (vs. lowest) SEP quartile. Estimates remained virtually unchanged after incremental adjustment for air pollution and transportation noise, and mediation by these environmental factors was found to be small. We found consistent evidence that residential green reduced the risk of mortality independently from other environmental

  2. LABORATORY EVALUATION OF AIR FLOW MEASUREMENT METHODS FOR RESIDENTIAL HVAC RETURNS

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-02-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  3. Development of a solar-powered residential air conditioner: Economic analysis

    Science.gov (United States)

    1975-01-01

    The results of investigations aimed at the development of cost models to be used in the economic assessment of Rankine-powered air conditioning systems for residential application are summarized. The rationale used in the development of the cost model was to: (1) collect cost data on complete systems and on the major equipment used in these systems; (2) reduce these data and establish relationships between cost and other engineering parameters such as weight, size, power level, etc; and (3) derive simple correlations from which cost-to-the-user can be calculated from performance requirements. The equipment considered in the survey included heat exchangers, fans, motors, and turbocompressors. This kind of hardware represents more than 2/3 of the total cost of conventional air conditioners.

  4. Prenatal exposure to residential air pollution and infant mental development: modulation by antioxidants and detoxification factors.

    Science.gov (United States)

    Guxens, Mònica; Aguilera, Inmaculada; Ballester, Ferran; Estarlich, Marisa; Fernández-Somoano, Ana; Lertxundi, Aitana; Lertxundi, Nerea; Mendez, Michelle A; Tardón, Adonina; Vrijheid, Martine; Sunyer, Jordi

    2012-01-01

    Air pollution effects on children's neurodevelopment have recently been suggested to occur most likely through the oxidative stress pathway. We aimed to assess whether prenatal exposure to residential air pollution is associated with impaired infant mental development, and whether antioxidant/detoxification factors modulate this association. In the Spanish INfancia y Medio Ambiente (INMA; Environment and Childhood) Project, 2,644 pregnant women were recruited during their first trimester. Nitrogen dioxide (NO2) and benzene were measured with passive samplers covering the study areas. Land use regression models were developed for each pollutant to predict average outdoor air pollution levels for the entire pregnancy at each residential address. Maternal diet was obtained at first trimester through a validated food frequency questionnaire. Around 14 months, infant mental development was assessed using Bayley Scales of Infant Development. Among the 1,889 children included in the analysis, mean exposure during pregnancy was 29.0 μg/m3 for NO2 and 1.5 μg/m3 for benzene. Exposure to NO2 and benzene showed an inverse association with mental development, although not statistically significant, after adjusting for potential confounders [β (95% confidence interval) = -0.95 (-3.90, 1.89) and -1.57 (-3.69, 0.56), respectively, for a doubling of each compound]. Stronger inverse associations were estimated for both pollutants among infants whose mothers reported low intakes of fruits/vegetables during pregnancy [-4.13 (-7.06, -1.21) and -4.37 (-6.89, -1.86) for NO2 and benzene, respectively], with little evidence of associations in the high-intake group (interaction p-values of 0.073 and 0.047). Inverse associations were also stronger in non-breast-fed infants and infants with low maternal vitamin D, but effect estimates and interactions were not significant. Our findings suggest that prenatal exposure to residential air pollutants may adversely affect infant mental

  5. Motor vehicle-related air toxics study. Final report

    International Nuclear Information System (INIS)

    1993-04-01

    Section 202 (1)(1) of the Clean Air Act (CAA), as amended (Section 206 of the Clean Air Act Amendments) (CAAA) of 1990 added paragraph (1) to Section 202 of the (CAA), directs the Environmental Protection Agency (EPA) to complete a study by May 15, 1992 of the need for, and feasibility of, controlling emissions of toxic air pollutants which are unregulated under the Act and associated with motor vehicles and motor vehicle fuels. The report has been prepared in response to Section 202 (1)(1). Specific pollutants or pollutant categories which are discussed in the report include benezene, formaldehyde, 1,3-butadiene, acetaldehyde, diesel particulate matter, gasoline particulate matter, and gasoline vapors as well as certain of the metals and motor vehicle-related pollutants identified in Section 112 of the Clean Air Act. The focus of the report is on carcinogenic risk. The study attempts to summarize what is known about motor vehicle-related air toxics and to present all significant scientific opinion on each issue

  6. Grandfather regulations, new source bias, and state air toxics regulations

    International Nuclear Information System (INIS)

    Levinson, Arik

    1999-01-01

    This paper uses plant-level data from the Census of Manufactures and the variation in toxic air pollution regulations across states to measure the effects of laws that are more stringent for new sources of pollution than for existing sources (so-called 'grandfather' regulations). Of particular interest is the resulting 'new source bias' and its effects on capital vintage and investment. Two industries are examined: commercial printing, which has a local product market; and paint manufacturing, which has a more national market. In general, there seem to be no statistically significant differences in capital vintage or investment between plants in states that grandfather new sources of pollution, plants in states that have no air toxics regulations, and plants in states that regulate both new and existing sources

  7. Indoor air pollutants in residential settings : respiratory health effects and remedial measures to minimize exposure

    Energy Technology Data Exchange (ETDEWEB)

    Small, B.M. [Small and Fleming Ltd., Georgetown, ON (Canada)

    2002-04-01

    The Ontario Lung Association's Movement for Clean Air Now (CAN DO) program focuses on educating the population about the possible adverse health effects of indoor air pollutants. The program is aimed at providing information on how to minimize exposure to pollutants in homes. This report presents an overview of the current understanding of, and recent developments in, specific indoor air quality issues and the extent to which they are know to present a risk to the respiratory health of the population, particularly the residential setting. Indoor air pollutants were assessed individually from a respiratory health perspective. The report describes the health problems associated with dampness, mould, bacteria, viruses, dust mites, cockroach antigen, animal dander, environmental tobacco smoke, products of combustion, products of emissions, radon, pesticides, and particulate matter. Each pollutant varies in nature, along with their potential respiratory effects, the degree of risk and the means of reducing exposure. Adverse respiratory health risks resulting from indoor pollutants can usually be reduced or eliminated by simple and practical measures such as eliminating dampness and water leakage, mould removal, sealing of soil gas entry points, cessation of smoking, and proper ventilation. the causal links between specific indoor pollutant exposures and specific adverse respiratory health symptoms was also examined. refs.

  8. Comparative economic assessment of the energy performance of air-conditioning within the Mexican residential sector

    Directory of Open Access Journals (Sweden)

    Ivan Oropeza-Perez

    2016-11-01

    Full Text Available This work shows a sensitivity analysis of the economic impact of different energy performances of air-conditioning within the Mexican housing sector. For this purpose, a cooling-load calculator program in function of the indoor temperature is developed. The program also calculates the electricity consumption along with the expenditure with the different residential rates of the Mexican Federal Commission of Electricity (CFE, initials in Spanish set according to the season of the year and zone of the country. After the results onto the national-scale scenario are validated with the literature, a sensitivity analysis is carried out by changing three parameters that are considered as influential on the consumption and which can be considered as energy saving strategies. With these strategies, it is found that the indoor temperature decrease due to the use of a passive cooling system is the most important characteristic to take into account followed by the coefficient of performance (COP of the air-conditioning and the increase of the comfort temperature set-point, respectively. Thereby, an economic analysis is carried out, finding an annual saving up to 770 USD within a single air-conditioned dwelling having a payback period of 3 years for using a combination of passive cooling techniques and increasing the comfort temperature set-point; or a 2 years payback period if the air-conditioning is changed by a high-efficient equipment.

  9. Toxicity of Silver Nanoparticles at the Air-Liquid Interface

    Science.gov (United States)

    Holder, Amara L.; Marr, Linsey C.

    2013-01-01

    Silver nanoparticles are one of the most prevalent nanomaterials in consumer products. Some of these products are likely to be aerosolized, making silver nanoparticles a high priority for inhalation toxicity assessment. To study the inhalation toxicity of silver nanoparticles, we have exposed cultured lung cells to them at the air-liquid interface. Cells were exposed to suspensions of silver or nickel oxide (positive control) nanoparticles at concentrations of 2.6, 6.6, and 13.2 μg cm−2 (volume concentrations of 10, 25, and 50 μg ml−1) and to 0.7 μg cm−2 silver or 2.1 μg cm−2 nickel oxide aerosol at the air-liquid interface. Unlike a number of in vitro studies employing suspensions of silver nanoparticles, which have shown strong toxic effects, both suspensions and aerosolized nanoparticles caused negligible cytotoxicity and only a mild inflammatory response, in agreement with animal exposures. Additionally, we have developed a novel method using a differential mobility analyzer to select aerosolized nanoparticles of a single diameter to assess the size-dependent toxicity of silver nanoparticles. PMID:23484109

  10. 77 FR 30274 - The Commission's Role Regarding the Environmental Protection Agency's Mercury and Air Toxics...

    Science.gov (United States)

    2012-05-22

    ... Role Regarding the Environmental Protection Agency's Mercury and Air Toxics Standards; Policy Statement on the Commission's Role Regarding the Environmental Protection Agency's Mercury and Air Toxics... noncompliance with EPA's Mercury and Air Toxics Standards (MATS).\\1\\ As noted below, this Policy Statement does...

  11. Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met. ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM2.5, formaldehyde and NO2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.

  12. Analysis of flow maldistribution in fin-and-tube evaporators for residential air-conditioning systems

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl

    validated and showed that a slip flow model need be used. A test case 8.8 kW residential air-conditioning system with R410A as refrigerant is chosen as baseline for the numerical investigations, and the simulations are performed at standard rating conditions from ANSI/AHRI Standard 210/240 (2008...... cases are standard tube circuitry designs and these results are thus tube circuitry specific. In addition, a novel method of compensating flow maldistribution is analyzed, i.e. the discontinuous liquid injection principle. The method is based upon the recently developed EcoFlowTM valve by Danfoss A...... profile across the A-coil evaporator was predicted by means of CFD simulation software STAR-CD 3.26 (2005) and applied in the numerical model. The main reason for the better face split evaporator performance at uniform conditions or when compensating, is that the superheated "weak" zones with low UA...

  13. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution....... Fin-and-tube heat exchangers usually have a predefined circuitry, however, the evaporator model is simplified to have straight tubes, in order to perform a generic investigation. The compensation of flow maldistribution is performed by control of the superheat in the individual channels. Furthermore......, the effect of combinations of individual maldistribution sources is investigated for different evaporator sizes and outdoor temperatures. It is shown that a decrease in cooling capacity and coefficient of performance by flow maldistribution can be compensated by the control of individual channel superheat...

  14. Exergy characteristics of a ceiling-type residential air conditioning system operating under different climatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Arif [Dept. of Mechanical Engineering, Ceyhan Engineering Faculty, Cukurova University, Adana (Turkmenistan)

    2016-11-15

    In this study an energy and exergy analysis of a Ceiling-type residential air conditioning (CTRAC) system operating under different climatic conditions have been investigated for provinces within the different geographic regions of Turkey. Primarily, the hourly cooling load capacities of a sample building (Q{sub evap}) during the months of April, May, June, July, August and September were determined. The hourly total heat gain of the sample building was determined using the Hourly analysis program (HAP). The Coefficient of performance (COP), exergy efficiency (η) and exergy destruction (Ex{sub dest}) values for the whole system and for each component were obtained. The results showed that lower atmospheric temperature (T{sub atm}) influenced the performance of the system and each of its components.

  15. Air condensation thermo-pumps for residential and small commercial buildings; Les thermopompes a condensation par air dans le residentiel et le petit tertiaire

    Energy Technology Data Exchange (ETDEWEB)

    Carteret, P. [Societe Airwell, (France)

    1997-12-31

    The advantages of recent air conditioning systems in terms of temperature control, air quality, air renewal, humidity control, air distribution, acoustic comfort, flexibility, are reviewed and some aspects concerning the evolution of the market in France are discussed (steady growth of the AC residential market). The different types of air conditioning systems are presented (direct expansion with the split-system, and cool water system); the characteristics, advantages and investment/operation costs of split-system and multi-splits thermo-pumps and hot water / cooled water production central units are described

  16. Development of a solar-powered residential air conditioner: Screening analysis

    Science.gov (United States)

    1975-01-01

    Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

  17. Emission Rates of Multiple Air Pollutants Generated from Chinese Residential Cooking.

    Science.gov (United States)

    Chen, Chen; Zhao, Yuejing; Zhao, Bin

    2018-02-06

    Household air pollution generated from cooking is severe, especially for Chinese-style cooking. We measured the emission rates of multiple air pollutants including fine particles (PM 2.5 ), ultrafine particles (UFPs), and volatile organic compounds (VOCs, including formaldehyde, benzene, and toluene) that were generated from typical Chinese cooking in a residential kitchen. The experiment was designed through five-factor and five-level orthogonal testing. The five key factors were cooking method, ingredient weight, type of meat, type of oil, and meat/vegetable ratio. The measured emission rates (mean value ± standard deviation) of PM 2.5 , UFPs, formaldehyde, total volatile organic compounds (TVOCs), benzene, and toluene were 2.056 ± 3.034 mg/min, 9.102 ± 6.909 × 10 12 #/min, 1.273 ± 0.736 mg/min, 1.349 ± 1.376 mg/min, 0.074 ± 0.039 mg/min, and 0.004 ± 0.004 mg/min. Cooking method was the most influencing factor for the emission rates of PM 2.5 , UFPs, formaldehyde, TVOCs, and benzene but not for toluene. Meanwhile, the emission rate of PM 2.5 was also significantly influenced by ingredient weight, type of meat, and meat/vegetable ratio. Exhausting the range hood decreased the emission rates by approximately 58%, with a corresponding air change rate of 21.38/h for the kitchen room.

  18. Spatiotemporal trend analysis of metal concentrations in sediments of a residential California stream with toxicity and regulatory implications.

    Science.gov (United States)

    Hall, Lenwood W; Anderson, Ronald D; Killen, William D

    2017-06-07

    The objective of this study was to determine if concentrations of arsenic, cadmium, chromium, copper, lead, nickel and zinc measured in the sediments of a residential stream in California (Pleasant Grove Creek) have changed temporally or spatially from 2006 to 2016. Threshold Effect Levels (TELs), conservative ecological effects benchmarks, and exceedances for the seven metals were also evaluated over the 11-year time period to provide insight into potential metal toxicity to resident benthic communities. In addition, the bioavailability of metals in sediments was also determined by calculating Simultaneous Extracted Metal/Acid Volatle Sulfide (SEM/AVS) ratios to allow an additional assessment of toxicity. Regulatory implications of this data set and the role of metal toxicity are also discussed. Stream-wide temporal trend analysis showed no statistically significant trends for any of the metals. However, spatial analysis for several sites located near storm drains did show a significant increase for most metals over the 11-year period. TEL exceedances during the 7 years of sampling, spanning 2006-2016, were reported for all metals with the number of exceedances ranging from 47 for copper and zinc to 1 for lead. A spatial analysis showed that the highest number of TEL exceedances and the highest number of SEM/AVS ratios greater than one with at least one metal exceeding a TEL occurred at upstream sites. The potentially toxic metal concentrations reported in Pleasant Grove Creek should be used in the 303 (d) listing process for impaired water bodies in California.

  19. Air toxics evaluation of ABB Combustion Engineering Low-Emission Boiler Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wesnor, J.D. [ABB/Combustion Engineering, Inc., Windsor, CT (United States)

    1993-10-26

    The specific goals of the program are to identify air toxic compounds that might be emmitted from the new boiler with its various Air Pollution Control device for APCD alternatives in levels of regulatory concern. For the compounds thought to be of concern, potential air toxic control methodologies will be suggested and a Test Protocol will be written to be used in the Proof of Concept and full scale tests. The following task was defined: Define Replations and Standards; Identify Air Toxic Pollutants of Interest to Interest to Utility Boilers; Assesment of Air Toxic By-Products; State of the Art Assessment of Toxic By-Product Control Technologies; and Test Protocol Definition.

  20. [Toxic fungi in Buenos Aires City and surroundings].

    Science.gov (United States)

    Romano, Gonzalo M; Iannone, Leopoldo; Novas, María V; Carmarán, Cecilia; Romero, Andrea I; López, Silvia E; Lechner, Bernardo E

    2013-01-01

    In Facultad de Ciencias Exactas y Naturales,Universidad de Buenos Aires there is a service called Servicio de Identificación de Hongos Tóxicos, directed by researchers of the Program of Medicinal Plants and Fungi Involved in Biological Degradation (PROPLAME-PRHIDEB, CONICET) that assist hospitals and other health establishments, identifying the different samples of fungi and providing information about their toxicity, so that patients can receive the correct treatment. The objective of the present study was to analyze all the cases received from 1985 to 2012. This analysis permitted the confection of a table identifying the most common toxic species. The information gathered revealed that 47% of the patients were under 18 years of age and had eaten basidiomes; the remaining 53% were adults who insisted that they were able to distinguish edible from toxic mushrooms. Chlorophyllum molybdites turned out to be the main cause of fungal intoxication in Buenos Aires, which is commonly confused with Macrolepiota procera, an edible mushroom. In the second place Amanita phalloides was registered, an agaric known to cause severe symptoms after a long period of latency (6-10 hours), and which can lead to hepatic failure even requiring a transplant to prevent severe internal injuries or even death, is not early and correctly treated.

  1. Semivolatile organic compounds in residential air along the Arizona - Mexico border

    Science.gov (United States)

    Gale, R.W.; Cranor, W.L.; Alvarez, D.A.; Huckins, J.N.; Petty, J.D.; Robertson, G.L.

    2009-01-01

    Concerns about indoor air quality and the potential effects on people living in these environments are increasing as more reports about the toxicities and the potential indoor air exposure levels of household-use chemicals and chemicals fromhousingandfurnishingmanufactureinairarebeingassessed. Gas chromatography/mass spectrometry was used to confirm numerous airborne contaminants obtained from the analysis of semipermeable membrane devices deployed inside of 52 homes situated along the border between Arizona and Mexico. We also describe nontarget analytes in the organochlorine pesticide fractions of 12 of these homes; this fraction is also the most likelytocontainthebroadestscopeofbioconcentratablechemicals accumulated from the indoor air. Approximately 400 individual components were identified, ranging from pesticides to a wide array of hydrocarbons, fragrances such as the musk xylenes, flavors relating to spices, aldehydes, alcohols, esters and phthalate esters, and other miscellaneous types of chemicals. The results presented in this study demonstrate unequivocally that the mixture of airborne chemicals present indoors is far more complex than previously demonstrated. ?? 2009 American Chemical Society.

  2. Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures

    International Nuclear Information System (INIS)

    Joudi, Khalid A.; Al-Amir, Qusay R.

    2014-01-01

    Highlights: • R290, R407C and R410A in residential split A/C units at high ambient. • 1 and 2 TR residential air conditioners with R22 alternatives at high ambient. • Residential split unit performance at ambients up to 55 °C with R22 alternatives. - Abstract: Steady state performance of residential air conditioning systems using R22 and alternatives R290, R407C, R410A, at high ambient temperatures, have been investigated experimentally. System performance parameters such as optimum refrigerant charge, coefficient of performance, cooling capacity, power consumption, pressure ratio, power per ton of refrigeration and TEWI environmental factor have been determined. All refrigerants were tested in the cooling mode operation under high ambient air temperatures, up to 55 °C, to determine their suitability. Two split type air conditioner of 1 and 2 TR capacities were used. A psychrometric test facility was constructed consisting of a conditioned cool compartment and an environmental duct serving the condenser. Air inside the conditioned compartment was maintained at 25 °C dry bulb and 19 °C wet bulb for all tests. In the environmental duct, the ambient air temperature was varied from 35 °C to 55 °C in 5 °C increments. The study showed that R290 is the better candidate to replace R22 under high ambient air temperatures. It has lower TEWI values and a better coefficient of performance than the other refrigerants tested. It is suitable as a drop-in refrigerant. R407C has the closest performance to R22, followed by R410A

  3. Tropospheric gas at potentially toxic levels in air

    Science.gov (United States)

    Bhattacharya, Atreyee

    2012-08-01

    Forest fires and emission of air pollutants, such as fumes from vehicles running on diesel and slow burning of coal and charcoal, release isocyanic acid in the troposphere. In 2011, scientists first detected isocyanic acid in the ambient atmosphere at levels toxic to human populations; at concentrations exceeding 1 part per billion by volume (ppbv), human beings could experience tissue decay when exposed to the toxin. For the first time, using a chemical transport model designed to estimate the distribution and budget of isocyanic acid in the troposphere, Young et al. showed that in several parts of the world, local emissions may increase the concentration of isocyanic acid in the ambient atmosphere, thereby exposing large populations to potentially toxic levels of the acid.

  4. Respiratory hospitalizations of children and residential exposure to traffic air pollution in Jerusalem.

    Science.gov (United States)

    Nirel, Ronit; Schiff, Michal; Paltiel, Ora

    2015-01-01

    Although exposure to traffic-related air pollution has been reported to be associated with respiratory morbidity in children, this association has not been examined in Israel. Jerusalem is ranked among the leading Israeli cities in transport-related air pollution. This case-control study examined whether pediatric hospitalization for respiratory diseases in Jerusalem is related to residential exposure to traffic-related air pollution. Cases (n=4844) were Jerusalem residents aged 0-14 years hospitalized for respiratory illnesses between 2000 and 2006. These were compared to children admitted electively (n=2161) or urgently (n=3085) for non-respiratory conditions. Individual measures of exposure included distance from residence to nearest main road, the total length of main roads, traffic volume, and bus load within buffers of 50, 150, and 300m around each address. Cases were more likely to have any diesel buses passing within 50m of their home (adjusted odds ratios=1.16 and 1.10, 95% confidence intervals 1.04-1.30 and 1.01-1.20 for elective and emergency controls, respectively). Our findings indicated that older girls (5-14) and younger boys (0-4) had increased risks of respiratory hospitalization, albeit with generally widened confidence intervals due to small sample sizes. Our results add to the limited body of evidence regarding associations between diesel exhaust particles and respiratory morbidity. The findings also point to possible differential associations between traffic-related air pollution and pediatric hospitalization among boys and girls in different age groups. Copyright © 2014 Elsevier GmbH. All rights reserved.

  5. Regional Air Toxics Modeling in California's San Francisco Bay Area

    Science.gov (United States)

    Martien, P. T.; Tanrikulu, S.; Tran, C.; Fairley, D.; Jia, Y.; Fanai, A.; Reid, S.; Yarwood, G.; Emery, C.

    2011-12-01

    Regional toxics modeling conducted for California's San Francisco Bay Area (SFBA) estimated potential cancer risk from diesel particulate matter (DPM) and four key reactive toxic gaseous pollutants (1,3-butadiene, benzene, formaldehyde, and acetaldehyde). Concentrations of other non-cancerous gaseous toxic air contaminants, including acrolein, were also generated. In this study, meteorological fields generated from July and December periods in 2000 and emissions from 2005 provided inputs to a three-dimensional air quality model at high spatial resolution (1x1 km^2 grid), from which a baseline set of annual risk values was estimated. Simulated risk maps show highest annual average DPM concentrations and cancer risks were located near and downwind of major freeways and near the Port of Oakland, a major container port in the area. Population weighted risks, using 2000 census data, were found to be highest in highly urbanized areas adjacent to significant DPM sources. For summer, the ratio of mean measured elemental carbon to mean modeled DPM was 0.78, conforming roughly to expectations. But for winter the ratio is 1.13, suggesting other sources of elemental carbon, such as wood smoke, are important. Simulated annual estimates for benzene and 1-3, butadiene compared well to measured annual estimates. Simulated acrolein and formaldehyde significantly under-predicted observed values. Simulations repeated using projected 2015 toxic emissions predicted that potential cancer risk dropped significantly in all areas throughout the SFBA. Emissions estimates for 2015 included the State of California's recently adopted on-road truck rule. Emission estimates of DPM are projected to drop about 70% between 2005 and 2015 in the SFBA, with a commensurate reduction in potential cancer risks. However, due to projected shifts in population during this period, with urban densification close to DPM sources outpacing emission reductions, there are some areas where population-weighted risks

  6. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Iyer, Maithili

    2009-05-30

    The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

  7. Differential effects of air conditioning type on residential endotoxin levels in a semi-arid climate.

    Science.gov (United States)

    Johnston, J D; Kruman, B A; Nelson, M C; Merrill, R M; Graul, R J; Hoybjerg, T G; Tuttle, S C; Myers, S J; Cook, R B; Weber, K S

    2017-09-01

    Residential endotoxin exposure is associated with protective and pathogenic health outcomes. Evaporative coolers, an energy-efficient type of air conditioner used in dry climates, are a potential source of indoor endotoxins; however, this association is largely unstudied. We collected settled dust biannually from four locations in homes with evaporative coolers (n=18) and central air conditioners (n=22) in Utah County, Utah (USA), during winter (Jan-Apr) and summer (Aug-Sept), 2014. Dust samples (n=281) were analyzed by the Limulus amebocyte lysate test. Housing factors were measured by survey, and indoor temperature and relative humidity measures were collected during both seasons. Endotoxin concentrations (EU/mg) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons. Endotoxin surface loads (EU/m 2 ) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons and in upholstered furniture during winter. For the nine significant season-by-location comparisons, EU/mg and EU/m 2 were approximately three to six times greater in homes using evaporative coolers. A plausible explanation for these findings is that evaporative coolers serve as a reservoir and distribution system for Gram-negative bacteria or their cell wall components in homes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Notification: Background Investigation Services EPA’s Efforts to Incorporate Environmental Justice Into Clean Air Act Inspections for Air Toxics

    Science.gov (United States)

    Project #OPE-FY14-0017, March 7, 2014. The OIG plans to begin the preliminary research phase of an evaluation of the EPA's efforts to incorporate environmental justice into Clean Air Act (CAA) inspections for air toxics.

  9. Investigating the Impact of Maternal Residential Mobility on Identifying Critical Windows of Susceptibility to Ambient Air Pollution During Pregnancy.

    Science.gov (United States)

    Warren, Joshua L; Son, Ji-Young; Pereira, Gavin; Leaderer, Brian P; Bell, Michelle L

    2017-10-19

    Identifying periods of increased vulnerability during pregnancy to air pollution with respect to the development of adverse birth outcomes can improve understanding of possible mechanisms of disease development and provide guidelines for protection of the child. Exposure to air pollution during pregnancy is typically based on the residence at delivery, potentially resulting in exposure misclassification and biasing the estimation of critical windows. In this work, we determine the impact of maternal residential mobility during pregnancy on defining weekly exposure to PM10 and the estimation of windows of susceptibility for term low birth weight utilizing birth cohort datasets from Connecticut (1988-2008) that include information on all residential addresses for each woman between conception and delivery. A simulation study is designed to investigate the impact of increasing levels of mobility on critical window identification. Increased PM10 exposure during pregnancy weeks 16-18 is associated with an increased probability of term low birth weight. Ignoring residential mobility when defining weekly exposure has only minor impact on the identification of critical windows for PM10 and term low birth weight in the data application and simulation study. Critical window identification is robust to exposure misclassification caused by ignoring residential mobility in these Connecticut birth cohorts. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Semivolatile organic compounds in residential air along the Arizona-Mexico border.

    Science.gov (United States)

    Gale, Robert W; Cranor, Walter L; Alvarez, David A; Huckins, James N; Petty, Jimmie D; Robertson, Gary L

    2009-05-01

    Concerns about indoor air quality and the potential effects on people living in these environments are increasing as more reports about the toxicities and the potential indoor air exposure levels of household-use chemicals and chemicals from housing and fumishing manufacture in air are being assessed. Gas chromatography/mass spectromery was used to confirm numerous airborne contaminants obtained from the analysis of semipermeable membrane devices deployed inside of 52 homes situated along the border between Arizona and Mexico. We also describe nontarget analytes in the organochlorine pesticide fractions of 12 of these homes; this fraction is also the most likely to contain the broadest scope of bioconcentratable chemicals accumulated from the indoor air. Approximately 400 individual components were identified, ranging from pesticides to a wide array of hydrocarbons, fragrances such as the musk xylenes, flavors relating to spices, aldehydes, alcohols, esters and phthalate esters, and other miscellaneous types of chemicals. The results presented in this study demonstrate unequivocally that the mixture of airborne chemicals present indoors is far more complex than previously demonstrated.

  11. Optimizing electric utility air toxics compliance with other titles of the Clean Air Act

    Energy Technology Data Exchange (ETDEWEB)

    Loeb, A.P.; South, D.W.

    1993-12-31

    This paper provides an overview of regulatory issues under Title III of the Clean Air Act Amendments that could affect electric utilities. Title III contains provisions relating to hazardous air pollutants (HAPs) and provides special treatment for electric utilities. Generally, this discussion documents that if utility toxic emissions are regulated, one of the chief difficulties confronting utilities will be the lack of coordination between Title III and other titles of the Act. The paper concludes that if the US Environmental Protection Agency (EPA) determines that regulation of utility HAPs is warranted under Title III, savings can be realized from flexible compliance treatment.

  12. Urban land use, air toxics and public health: Assessing hazardous exposures at the neighborhood scale

    International Nuclear Information System (INIS)

    Corburn, Jason

    2007-01-01

    Land use data are increasingly understood as important indicators of potential environmental health risk in urban areas where micro-scale or neighborhood level hazard exposure data are not routinely collected. This paper aims to offer a method for estimating the distribution of air toxics in urban neighborhoods using land use information because actual air monitoring data rarely exist at this scale. Using Geographic Information System spatial modeling tools, we estimate air toxics concentrations across neighborhoods in New York City and statistically compare our model with the US Environmental Protection Agency's National Air Toxic Assessment and air monitoring data across three NYC neighborhoods. We conclude that land use data can act as a good proxy for estimating neighborhood scale air toxics, particularly in the absence of monitoring data. In addition, the paper suggests that land use data can expand the reach of environmental impact assessments that routinely exclude analyses of potential exposures to urban air toxics at the neighborhood scale

  13. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measurements included testing of the filters, separately and combined, in a ductwork to study the efficiency......This study is part of a research project concerning the possibilities of applying efficient air cleaning technologies using rotary heat exchanger in residential buildings. The purpose of this project was to identify and adapt new air-cleaning technologies for implementation in HVAC systems...... was approximately 5 Pascal at an airflow rate of 216 m3/h. The air velocity through the filter was 0.49 m/s. Furthermore, the removal efficiency of the combined filter for 6 chemical substances were examined using Hexane, Butanol, 2-Ethylhexanol, Heptane, 2-Heptanone and Acetaldehyde as sources for emission...

  14. Impact of Residential Mobility on Exposure Assessment in Longitudinal Air Pollution Studies: A Sensitivity Analysis within the ESCAPE Project

    Directory of Open Access Journals (Sweden)

    Anna Oudin

    2012-01-01

    Full Text Available Exposure misclassification in longitudinal studies of air pollution exposure and health effects can occur due to residential mobility in a study population over followup. The aim of this study was to investigate to what extent residential mobility during followup can be expected to cause exposure misclassification in such studies, where exposure at the baseline address is used as the main exposure assessment. The addresses for each participant in a large population-based study (N>25,000 were obtained via national registers. We used a Land Use Regression model to estimate the NOx concentration for each participant's all addresses during the entire follow-up period (in average 14.6 years and calculated an average concentration during followup. The Land Use Regression model explained 83% of the variation in measured levels. In summary, the NOx concentration at the inclusion address was similar to the average concentration over followup with a correlation coefficient of 0.80, indicating that air pollution concentration at study inclusion address could be used as indicator of average air pollution concentrations over followup. The differences between an individual's inclusion and average follow-up mean concentration were small and seemed to be nondifferential with respect to a large range of factors and disease statuses, implying that bias due to residential mobility was small.

  15. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    International Nuclear Information System (INIS)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors

  16. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  17. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA`s Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  18. The contribution of residential coal combustion to the air quality in Beijing-Tianjin-Hebei (BTH), China: A case study

    Science.gov (United States)

    Li, X.; Li, G.; Junji, C.

    2017-12-01

    In the present study, a persistent heavy haze episode from 13 to 20 January 2014 in Beijing-Tianjin-Hebei (BTH) is simulated using the WRF-CHEM model to evaluate the contribution of residential coal combustion to the air quality. The residential coal used in BTH is replaced by the water-quenched semi-coke with much lower emission factors (EFs) in simulations. The EFs of OC for water-quenched semi-coke (0.12 g kg-1) is 2.42 times lower than that for residential coal used in Beijing-Tianjin (0.29 g kg-1) and 9.17 times in Hebei (1.1 g kg-1). The WRF-CHEM model reasonably well reproduces the spatial distributions and temporal variations of PM2.5 mass concentrations in BTH against the observations over monitoring sites and the temporal variations of aerosol species compared to the AMS measurements in Beijing. On average, the PM2.5 concentration is reduced by around 20 µg m-3 due to the residential coal replacement. Organic aerosols constitute about 62.3% of the PM2.5 reduction in BTH, much higher than the contribution from sulfate (7.0%), nitrate (3.1%), and ammonium (3.1%). In addition, the usage of water-quenched semi-coke in BTH also significantly reduces polycyclic aromatic hydrocarbon (PAHs) concentrations by 50-450 ng m-3 on average. Therefore, the usage of water-quenched semi-coke in BTH could considerably reduce the emissions of air pollutants and decrease the PM2.5 level, beneficial to improvement of the air quality in BTH.

  19. Residential heating contribution to level of air pollutants (PAHs, major, trace, and rare earth elements): a moss bag case study.

    Science.gov (United States)

    Vuković, Gordana; Aničić Urošević, Mira; Pergal, Miodrag; Janković, Milan; Goryainova, Zoya; Tomašević, Milica; Popović, Aleksandar

    2015-12-01

    In areas with moderate to continental climates, emissions from residential heating system lead to the winter air pollution peaks. The EU legislation requires only the monitoring of airborne concentrations of particulate matter, As, Cd, Hg, Ni, and B[a]P. Transition metals and rare earth elements (REEs) have also arisen questions about their detrimental health effects. In that sense, this study examined the level of extensive set of air pollutants: 16 polycyclic aromatic hydrocarbons (PAHs), and 41 major elements, trace elements, and REEs using Sphagnum girgensohnii moss bag technique. During the winter of 2013/2014, the moss bags were exposed across Belgrade (Serbia) to study the influence of residential heating system to the overall air quality. The study was set as an extension to our previous survey during the summer, i.e., non-heating season. Markedly higher concentrations of all PAHs, Sb, Cu, V, Ni, and Zn were observed in the exposed moss in comparison to the initial values. The patterns of the moss REE concentrations normalized to North American Shale Composite and Post-Archean Australian Shales were identical across the study area but enhanced by anthropogenic activities. The results clearly demonstrate the seasonal variations in the moss enrichment of the air pollutants. Moreover, the results point out a need for monitoring of air quality during the whole year, and also of various pollutants, not only those regulated by the EU Directive.

  20. Characterization and Quantification of Hexavalent Chromium and Other Toxic Metals in the Air of Communities Surrounding Metal Processing Facilities

    Science.gov (United States)

    Pikelnaya, O.; Polidori, A.; Low, J.

    2017-12-01

    Hexavalent chromium [Cr(VI)] and other toxic metals are often emitted during metal forging, cutting, grinding and plating operations. In the South Coast Air Basin (SCAB) many of such operations are conducted by relatively small facilities intertwined within residential communities in the cities of Paramount, Compton, Long Beach and Anaheim. In response to the city of Paramount community members' complaints of "metallic" odors, the South Coast Air Quality Management District (SCAQMD) initiated a local air sampling study for toxic metals, which found elevated Cr(VI) and nickel levels in the community downwind of selected metal processing facilities. SCAQMD worked with these facilities to reduce the emissions from their metal grinding operations, which resulted in substantial reduced nickel levels, but did not reduce Cr(VI) levels. In order to fully understand the source(s) of these emissions, SCAQMD has been deploying portable samplers for Cr(VI) monitoring throughout the city of Paramount since October 2016. During this presentation we will discuss the results of more than a year of Cr(VI) analyses of samplers collected throughout the City of Paramount, as well as data from a continuous metal monitor deployed at one of the sites. We will also discuss options and challenges for expanding of Cr(VI) monitoring to other communities in the SCAB that are adjacent to metal forging and grinding operations; and explore emerging new technologies to address such monitoring challenges.

  1. Advanced combustor design concept to control NOx and air toxics

    Energy Technology Data Exchange (ETDEWEB)

    Eddings, E.G.; Pershing, D.W.; Molina, A.; Sarofim, A.F.; Spinti, J.P.; Veranth, J.

    1999-03-29

    Direct coal combustion needs to be a primary energy source for the electric utility industry and for heavy manufacturing during the next several decades because of the availability and economic advantage of coal relative to other fuels and because of the time required to produce major market penetration in the energy field. However, the major obstacle to coal utilization is a set of ever-tightening environmental regulations at both the federal and local level. It is, therefore, critical that fundamental research be conducted to support the development of low-emission, high-efficiency pulverized coal power systems. The objective of this program was to develop fundamental understanding regarding the impact of fuel and combustion changes on NOx formation, carbon burnout and air toxic emissions from pulverized coal (pc) combustion. During pc combustion, nitrogen in the coal can be oxidized to form nitrogen oxides (NO{sub x}). The 1990 Clean Air Act Amendments established much stricter NO{sub x} emissions limits for new and existing coal-fired plants, so there has been renewed interest in the processes by which NO{sub x} forms in pc flames. One of the least understood aspects of NO{sub x} formation from pc combustion is the process by which char-N (nitrogen remaining in the char after devolatilization) forms either NO{sub x} or N{sub 2}, and the development of a fundamental understanding of this process was a major focus of this research. The overall objective of this program was to improve the ability of combustion system designers and boiler manufacturers to build high efficiency, low emission pulverized coal systems by improving the design tools available to the industry. The specific program goals were to: Use laboratory experiments and modeling to develop fundamental understanding for a new submodel for char nitrogen oxidation (a critical piece usually neglected in most NOx models.); Use existing bench scale facilities to investigate alternative schemes to

  2. Studying the Infleunce of Burning Fireworks on Air Quality and Human Health in a Residential Area

    Science.gov (United States)

    Kota, S. H.; Garaga, R.

    2016-12-01

    India observes Diwali as the celebration of lights, which fully brightens the nation with its splendour, and amazes all with its happiness. To understand the impact of fireworks on air quality and human health, a ten-day short term study was conducted in one of the residential colleges in North-East India. The PM10 concentration during fireworks was 311µg/m3, which was 81% higher than a normal day. Additionally, ambient noise level measured during fireworks day was found to be 101 dB, which was 65% higher than a normal day's mean noise level. SO42-, NO3-, Cl-, F-, Na+, Ca2+, NH4+, K+, Zn, Fe, Cd, Co, Ni and Sr increased by 1.29, 0.51, 0.48, 1.08, 0.6, 0.54, 1.79, 1.43, 1.72, 0.34, 0.42, 0.82, 0.56, 0.17 times respectively, on fireworks compared to a normal day. Additionally, microorganisms decreased by 40% to the concentration of CFU/m3, on fireworks day. This implies that the fireworks burning inhibit the growth of microbial activity. The source apportionment studies carried out using principal component analysis revealed five factors related to fireworks, construction activities, biomass burning, vehicle emission and industries. The average number of patients in the hospital increased three folds, evidently signifying the negative impact of fireworks on human health. Patients suffering from cough, sneezing, headache and nasal congestion increased by 64, 69, 65 and 82%, respectively. This study stresses the importance of regulated and monitored practice of burning of fireworks in regions with high population density.

  3. 76 FR 80727 - Flexible Implementation of the Mercury and Air Toxics Standards Rule

    Science.gov (United States)

    2011-12-27

    ... emissions of mercury and other toxic air pollutants from power plants, which collectively are among the... Air Toxics Standards rule for power plants (the ``MATS Rule'') represents a major step forward in my... Commission, State utility regulators, Regional Transmission Organizations, the North American Electric...

  4. Modeling global residential sector energy demand for heating and air conditioning in the context of climate change

    International Nuclear Information System (INIS)

    Isaac, Morna; Vuuren, Detlef P. van

    2009-01-01

    In this article, we assess the potential development of energy use for future residential heating and air conditioning in the context of climate change. In a reference scenario, global energy demand for heating is projected to increase until 2030 and then stabilize. In contrast, energy demand for air conditioning is projected to increase rapidly over the whole 2000-2100 period, mostly driven by income growth. The associated CO 2 emissions for both heating and cooling increase from 0.8 Gt C in 2000 to 2.2 Gt C in 2100, i.e. about 12% of total CO 2 emissions from energy use (the strongest increase occurs in Asia). The net effect of climate change on global energy use and emissions is relatively small as decreases in heating are compensated for by increases in cooling. However, impacts on heating and cooling individually are considerable in this scenario, with heating energy demand decreased by 34% worldwide by 2100 as a result of climate change, and air-conditioning energy demand increased by 72%. At the regional scale considerable impacts can be seen, particularly in South Asia, where energy demand for residential air conditioning could increase by around 50% due to climate change, compared with the situation without climate change

  5. Quantifying the impact of residential heating on the urban air quality in a typical European coal combustion region.

    Science.gov (United States)

    Junninen, Heikki; Mønster, Jacob; Rey, Maria; Cancelinha, Jose; Douglas, Kevin; Duane, Matthew; Forcina, Victtorio; Müller, Anne; Lagler, Fritz; Marelli, Luisa; Borowiak, Annette; Niedzialek, Joanna; Paradiz, Bostian; Mira-Salama, Daniel; Jimenez, Jose; Hansen, Ute; Astorga, Covadonga; Stanczyk, Krzysztof; Viana, Mar; Querol, Xavier; Duvall, Rachelle M; Norris, Gary A; Tsakovski, Stefan; Wåhlin, Peter; Horák, Jiri; Larsen, Bo R

    2009-10-15

    The present investigation, carried out as a case study in a typical major city situated in a European coal combustion region (Krakow, Poland), aims at quantifying the impact on the urban air quality of residential heating by coal combustion in comparison with other potential pollution sources such as power plants, industry, and traffic. Emissions were measured for 20 major sources, including small stoves and boilers, and the particulate matter (PM) was analyzed for 52 individual compounds together with outdoor and indoor PM10 collected during typical winter pollution episodes. The data were analyzed using chemical mass balance modeling (CMB) and constrained positive matrix factorization (CMF) yielding source apportionments for PM10, B(a)P, and other regulated air pollutants namely Cd, Ni, As, and Pb. The results are potentially very useful for planning abatement strategies in all areas of the world, where coal combustion in small appliances is significant. During the studied pollution episodes in Krakow, European air quality limits were exceeded with up to a factor 8 for PM10 and up to a factor 200 for B(a)P. The levels of these air pollutants were accompanied by high concentrations of azaarenes, known markers for inefficient coal combustion. The major culprit for the extreme pollution levels was demonstrated to be residential heating by coal combustion in small stoves and boilers (>50% for PM10 and >90% B(a)P), whereas road transport (industrial emission of the precursors SO2 and NOx.

  6. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

    DEFF Research Database (Denmark)

    Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub

    Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review...... of the existing literature, to establish a link between ventilation rate and key indoor air pollutants. Design characteristics of a mechanical ventilation system such as supply/exhaustairflow, system and design of supply and exhaust outlets were considered. The performance of various ventilation solutionswas......-house ventilation rate was reported below 0.5h-1 or 14 l/s·person in bedrooms, the concentrations of the pollutants elevated above minimum threshold limits (CO2>1350 ppm; TVOC >3000 μg/m3) defined by the standard. Insufficient or non-existent supply of air was related to significantly higher pollutant...

  7. Occurrence and Concentrations of Toxic VOCs in the Ambient Air of Gumi, an Electronics-Industrial City in Korea.

    Science.gov (United States)

    Baek, Sung-Ok; Suvarapu, Lakshmi Narayana; Seo, Young-Kyo

    2015-08-05

    This study was carried out to characterize the occurrence and concentrations of a variety of volatile organic compounds (VOCs) including aliphatic, aromatic, halogenated, nitrogenous, and carbonyl compounds, in the ambient air of Gumi City, where a large number of electronics industries are found. Two field monitoring campaigns were conducted for a one year period in 2003/2004 and 2010/2011 at several sampling sites in the city, representing industrial, residential and commercial areas. More than 80 individual compounds were determined in this study, and important compounds were then identified according to their abundance, ubiquity and toxicity. The monitoring data revealed toluene, trichloroethylene and acetaldehyde to be the most significant air toxics in the city, and their major sources were mainly industrial activities. On the other hand, there was no clear evidence of an industrial impact on the concentrations of benzene and formaldehyde in the ambient air of the city. Overall, seasonal variations were not as distinct as locational variations in the VOCs concentrations, whereas the within-day variations showed a typical pattern of urban air pollution, i.e., increase in the morning, decrease in the afternoon, and an increase again in the evening. Considerable decreases in the concentrations of VOCs from 2003 to 2011 were observed. The reductions in the ambient concentrations were confirmed further by the Korean PRTR data in industrial emissions within the city. Significant decreases in the concentrations of benzene and acetaldehyde were also noted, whereas formaldehyde appeared to be almost constant between the both campaigns. The decreased trends in the ambient levels were attributed not only to the stricter regulations for VOCs in Korea, but also to the voluntary agreement of major companies to reduce the use of organic solvents. In addition, a site planning project for an eco-friendly industrial complex is believed to play a contributory role in improving

  8. Occurrence and Concentrations of Toxic VOCs in the Ambient Air of Gumi, an Electronics-Industrial City in Korea

    Directory of Open Access Journals (Sweden)

    Sung-Ok Baek

    2015-08-01

    Full Text Available This study was carried out to characterize the occurrence and concentrations of a variety of volatile organic compounds (VOCs including aliphatic, aromatic, halogenated, nitrogenous, and carbonyl compounds, in the ambient air of Gumi City, where a large number of electronics industries are found. Two field monitoring campaigns were conducted for a one year period in 2003/2004 and 2010/2011 at several sampling sites in the city, representing industrial, residential and commercial areas. More than 80 individual compounds were determined in this study, and important compounds were then identified according to their abundance, ubiquity and toxicity. The monitoring data revealed toluene, trichloroethylene and acetaldehyde to be the most significant air toxics in the city, and their major sources were mainly industrial activities. On the other hand, there was no clear evidence of an industrial impact on the concentrations of benzene and formaldehyde in the ambient air of the city. Overall, seasonal variations were not as distinct as locational variations in the VOCs concentrations, whereas the within-day variations showed a typical pattern of urban air pollution, i.e., increase in the morning, decrease in the afternoon, and an increase again in the evening. Considerable decreases in the concentrations of VOCs from 2003 to 2011 were observed. The reductions in the ambient concentrations were confirmed further by the Korean PRTR data in industrial emissions within the city. Significant decreases in the concentrations of benzene and acetaldehyde were also noted, whereas formaldehyde appeared to be almost constant between the both campaigns. The decreased trends in the ambient levels were attributed not only to the stricter regulations for VOCs in Korea, but also to the voluntary agreement of major companies to reduce the use of organic solvents. In addition, a site planning project for an eco-friendly industrial complex is believed to play a contributory

  9. Occurrence and Concentrations of Toxic VOCs in the Ambient Air of Gumi, an Electronics-Industrial City in Korea

    Science.gov (United States)

    Baek, Sung-Ok; Suvarapu, Lakshmi Narayana; Seo, Young-Kyo

    2015-01-01

    This study was carried out to characterize the occurrence and concentrations of a variety of volatile organic compounds (VOCs) including aliphatic, aromatic, halogenated, nitrogenous, and carbonyl compounds, in the ambient air of Gumi City, where a large number of electronics industries are found. Two field monitoring campaigns were conducted for a one year period in 2003/2004 and 2010/2011 at several sampling sites in the city, representing industrial, residential and commercial areas. More than 80 individual compounds were determined in this study, and important compounds were then identified according to their abundance, ubiquity and toxicity. The monitoring data revealed toluene, trichloroethylene and acetaldehyde to be the most significant air toxics in the city, and their major sources were mainly industrial activities. On the other hand, there was no clear evidence of an industrial impact on the concentrations of benzene and formaldehyde in the ambient air of the city. Overall, seasonal variations were not as distinct as locational variations in the VOCs concentrations, whereas the within-day variations showed a typical pattern of urban air pollution, i.e., increase in the morning, decrease in the afternoon, and an increase again in the evening. Considerable decreases in the concentrations of VOCs from 2003 to 2011 were observed. The reductions in the ambient concentrations were confirmed further by the Korean PRTR data in industrial emissions within the city. Significant decreases in the concentrations of benzene and acetaldehyde were also noted, whereas formaldehyde appeared to be almost constant between the both campaigns. The decreased trends in the ambient levels were attributed not only to the stricter regulations for VOCs in Korea, but also to the voluntary agreement of major companies to reduce the use of organic solvents. In addition, a site planning project for an eco-friendly industrial complex is believed to play a contributory role in improving

  10. Comparison of adsorption systems using natural gas fired fuel cell as heat source, for residential air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Clausse, M.; Meunier, F. [LGP2ES, Cnam-IFFI (EA21), case 331, 292 rue Saint-Martin, 75141 Paris Cedex 03 (France); Coulie, J.; Herail, E. [N-GHY, Site Industriel Saint Antoine, ZI Montplaisir, 51 rue Isaac Newton, 81000 Albi (France)

    2009-06-15

    This article aims to evaluate the performances of an adsorption system driven thanks to the heat rejected by the post-combustion exhaust gases of a reformer/fuel cell system for residential air-conditioning application. Three adsorption pairs were compared: activated carbon/methanol, silica gel/water and zeolite/water. Taking into account both cooling power and sensitivity to performances of the heat rejection and recovery exchangers, it appears that zeolite 13X/water is the adsorption pair giving the best performance for this application. Nevertheless, a more detailed model would be of interest to better quantify the heat transfer impact on performance. (author)

  11. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  12. Optimal replacement of residential air conditioning equipment to minimize energy, greenhouse gas emissions, and consumer cost in the US

    International Nuclear Information System (INIS)

    De Kleine, Robert D.; Keoleian, Gregory A.; Kelly, Jarod C.

    2011-01-01

    A life cycle optimization of the replacement of residential central air conditioners (CACs) was conducted in order to identify replacement schedules that minimized three separate objectives: life cycle energy consumption, greenhouse gas (GHG) emissions, and consumer cost. The analysis was conducted for the time period of 1985-2025 for Ann Arbor, MI and San Antonio, TX. Using annual sales-weighted efficiencies of residential CAC equipment, the tradeoff between potential operational savings and the burdens of producing new, more efficient equipment was evaluated. The optimal replacement schedule for each objective was identified for each location and service scenario. In general, minimizing energy consumption required frequent replacement (4-12 replacements), minimizing GHG required fewer replacements (2-5 replacements), and minimizing cost required the fewest replacements (1-3 replacements) over the time horizon. Scenario analysis of different federal efficiency standards, regional standards, and Energy Star purchases were conducted to quantify each policy's impact. For example, a 16 SEER regional standard in Texas was shown to either reduce primary energy consumption 13%, GHGs emissions by 11%, or cost by 6-7% when performing optimal replacement of CACs from 2005 or before. The results also indicate that proper servicing should be a higher priority than optimal replacement to minimize environmental burdens. - Highlights: → Optimal replacement schedules for residential central air conditioners were found. → Minimizing energy required more frequent replacement than minimizing consumer cost. → Significant variation in optimal replacement was observed for Michigan and Texas. → Rebates for altering replacement patterns are not cost effective for GHG abatement. → Maintenance levels were significant in determining the energy and GHG impacts.

  13. Particulate emissions from residential wood combustion: Final report: Norteast regional Biomass Program

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    The objective of this study was to provide a resource document for the Northeastern states when pursuing the analysis of localized problems resulting from residential wood combustion. Specific tasks performed include assigning emission rates for total suspended particulates (TSP) and benzo(a)pyrene (BaP) from wood burning stoves, estimating the impact on ambient air quality from residential wood combustion and elucidating the policy options available to Northeastern states in their effort to limit any detrimental effects resulting from residential wood combustion. Ancillary tasks included providing a comprehensive review on the relevant health effects, indoor air pollution and toxic air pollutant studies. 77 refs., 11 figs., 25 tabs.

  14. Towards the definition of indicators for assessment of indoor air quality and energy performance in low-energy residential buildings

    DEFF Research Database (Denmark)

    Cony Renaud Salis, Louis; Abadie, Marc; Wargocki, Pawel

    2017-01-01

    -pinene, benzene, carbon dioxide, formaldehyde, naphthalene, nitrogen dioxide, PM10, PM2.5, radon, styrene, toluene, trichloroethylene, TVOC and mould. Both short-term and long-term effects of these pollutants were considered. The compound with the highest ratio of concentration to its exposure limit value...... to develop such an IAQ index is that hundreds of chemical compounds are present in indoor air, including residential environments, at concentrations much lower than occurring during occupational exposures. There is a lack of clear consensus on which pollutant or group of pollutants should be used to form...... was proposed as the IAQ index for the short term effects so that the existing exposure limits could be referred to and to avoid problems associated with the aggregation of many air quality indices. The same approach was proposed for the IAQ index for the long-term effects together with the calculation...

  15. Application of multicriteria decision making methods to air quality in the microenvironments of residential houses in Brisbane, Australia.

    Science.gov (United States)

    Ayoko, Godwin A; Morawska, Lidia; Kokot, Serge; Gilbert, Dale

    2004-05-01

    This paper reports the first application of the multicriteria decision making methods, PROMETHEE and GAIA, to indoor and outdoor air quality data. Fourteen residential houses in a suburb of Brisbane, Australia were investigated for 21 air quality-influencing criteria, which included the characteristics of the houses as well as the concentrations of volatile organic compounds, fungi, bacteria, submicrometer, and supermicrometer particles in their indoor and outdoor air samples. Ranking information necessary to select one house in preference to all others and to assess the parameters influencing the differentiation of the houses was found with the aid of PROMETHEE and GAIA. There was no correlation between the rank order of each house and the health complaints of its occupants. Patterns in GAIA plots show that indoor air quality in these houses is strongly dependent on the characteristics of the houses (construction material, distance of the house from a major road, and the presence of an in-built garage). Marked similarities were observed in the patterns obtained when GAIA and factor analysis were applied to the data. This underscores the potential of PROMETHEE and GAIA to provide information that can assist source apportionment and elucidation of effective remedial measures for indoor air pollution.

  16. Modeling the residential infiltration of outdoor PM(2.5) in the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air).

    Science.gov (United States)

    Allen, Ryan W; Adar, Sara D; Avol, Ed; Cohen, Martin; Curl, Cynthia L; Larson, Timothy; Liu, L-J Sally; Sheppard, Lianne; Kaufman, Joel D

    2012-06-01

    Epidemiologic studies of fine particulate matter [aerodynamic diameter ≤ 2.5 μm (PM(2.5))] typically use outdoor concentrations as exposure surrogates. Failure to account for variation in residential infiltration efficiencies (F(inf)) will affect epidemiologic study results. We aimed to develop models to predict F(inf) for > 6,000 homes in the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air), a prospective cohort study of PM(2.5) exposure, subclinical cardiovascular disease, and clinical outcomes. We collected 526 two-week, paired indoor-outdoor PM(2.5) filter samples from a subset of study homes. PM(2.5) elemental composition was measured by X-ray fluorescence, and F(inf) was estimated as the indoor/outdoor sulfur ratio. We regressed F(inf) on meteorologic variables and questionnaire-based predictors in season-specific models. Models were evaluated using the R² and root mean square error (RMSE) from a 10-fold cross-validation. The mean ± SD F(inf) across all communities and seasons was 0.62 ± 0.21, and community-specific means ranged from 0.47 ± 0.15 in Winston-Salem, North Carolina, to 0.82 ± 0.14 in New York, New York. F(inf) was generally greater during the warm (> 18°C) season. Central air conditioning (AC) use, frequency of AC use, and window opening frequency were the most important predictors during the warm season; outdoor temperature and forced-air heat were the best cold-season predictors. The models predicted 60% of the variance in 2-week F(inf), with an RMSE of 0.13. We developed intuitive models that can predict F(inf) using easily obtained variables. Using these models, MESA Air will be the first large epidemiologic study to incorporate variation in residential F(inf) into an exposure assessment.

  17. Chemical concentrations, exposures, health risks by census tract from National Scale Air Toxics Assessment (NATA)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Chemical concentrations, exposures, health risks by census tract for the United States from National Scale Air Toxics Assessment (NATA). This dataset is associated...

  18. Characterization of Reduced Toxicity, High Performance Monopropellants at the U.S. Air Force Research Laboratory

    National Research Council Canada - National Science Library

    Hawkins, T

    2001-01-01

    Current U.S. Air Force programs are working to develop reduced toxicity monopropellant formulations to replace spacecraft hydrazine monopropellant and exceed the monopropellant performance objective (greater than 50...

  19. Biodiesel and Cold Temperature Effects on Speciated Mobile Source Air Toxics from Modern Diesel Trucks

    Science.gov (United States)

    Speciated volatile organic compounds (VOCs) with a particular focus on mobile source air toxics (MSATs) were measured in diesel exhaust from three heavy-duty trucks equipped with modern aftertreatment technologies. Emissions testing was conducted on a temperature controlled chass...

  20. Biodiesel and Cold Temperature Effect on Speciated Mobile Source Air Toxics from Modern Diesel Trucks

    Science.gov (United States)

    Speciated volatile organic compounds (VOCs) with a particular focus on mobile source air toxics (MSATs) were measured in diesel exhaust from three heavy-duty trucks equipped with modern aftertreatment technologies. Emissions testing was conducted on a temperature controlled chass...

  1. Observation of elevated air pollutant concentrations in a residential neighborhood of Los Angeles California using a mobile platform

    Science.gov (United States)

    Hu, Shishan; Paulson, Suzanne E.; Fruin, Scott; Kozawa, Kathleen; Mara, Steve; Winer, Arthur M.

    2012-05-01

    We observed elevated air pollutant concentrations, especially of ultrafine particles (UFP), black carbon (BC) and NO, across the residential neighborhood of the Boyle Heights Community (BH) of Los Angeles, California. Using an electric vehicle mobile platform equipped with fast response instruments, real-time air pollutant concentrations were measured in BH in spring and summer of 2008. Pollutant concentrations varied significantly in the two seasons, on different days, and by time of day, with an overall average UFP concentration in the residential areas of ∼33 000 cm-3. The averaged UFP, BC, and NO concentrations measured on Soto St, a major surface street in BH, were 57 000 cm-3, 5.1 μg m-3, and 67 ppb, respectively. Concentrations of UFP across the residential areas in BH were nearly uniform spatially, in contrast to other areas in the greater metropolitan area of Los Angeles where UFP concentrations exhibit strong gradients downwind of roadways. We attribute this “UFP cloud” to high traffic volumes, including heavy duty diesel trucks on the freeways which surround and traverse BH, and substantial numbers of high-emitting vehicles (HEVs) on the surface streets traversing BH. Additionally, the high density of stop signs and lights and short block lengths, requiring frequent accelerations of vehicles, may contribute. The data also support a role for photochemical production of UFP in the afternoon. UFP concentration peaks (5 s average) of up to 9 million particles cm-3 were also observed immediately behind HEVs when they accelerated from stop lights in the BH neighborhood and areas immediately adjacent. Although encounters with HEV during mornings accounted for only about 6% and 17% of time spent monitoring residential areas and major surface streets, HEV contributed to about 28% and 53% of total ultrafine particles measured on the route, respectively. The observation of elevated pollutant concentrations across the Boyle Heights community highlights

  2. Toxic and hazardous air pollutants from co-firing biomass fuels, fossil fuels, MSW and RDF

    International Nuclear Information System (INIS)

    Junge, D.C.

    1991-01-01

    Toxic and hazardous pollutants are defined and then are considered from the perspective of pollutants which enter the combustion process with the fuel (principally the metals and metallic compounds) and pollutants which are formed as products of incomplete combustion. Control strategies are reviewed through the entire process including fuel preparation and storage, combustion control and the application of air pollution control devices. Measurement techniques for specific toxic and hazardous air pollutants are discussed

  3. Mitigating the Impacts of Uncontrolled Air Flow on Indoor Environmental Quality and Energy Demand in Non-Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hugh I. Henderson; Jensen Zhang; James B. Cummings; Terry Brennan

    2006-07-31

    This multi-faceted study evaluated several aspects of uncontrolled air flows in commercial buildings in both Northern and Southern climates. Field data were collected from 25 small commercial buildings in New York State to understand baseline conditions for Northern buildings. Laboratory wall assembly testing was completed at Syracuse University to understand the impact of typical air leakage pathways on heat and moisture transport within wall assemblies for both Northern and Southern building applications. The experimental data from the laboratory tests were used to verify detailed heat and moisture (HAM) simulation models that could be used to evaluate a wider array of building applications and situations. Whole building testing at FSEC's Building Science Laboratory (BSL) systematically evaluated the energy and IAQ impacts of duct leakage with various attic and ceiling configurations. This systematic test carefully controlled all aspects of building performance to quantify the impact of duct leakage and unbalanced flow. The newest features of the EnergyPlus building simulation tool were used to model the combined impacts of duct leakage, ceiling leakage, unbalanced flows, and air conditioner performance. The experimental data provided the basis to validate the simulation model so it could be used to study the impact of duct leakage over a wide range of climates and applications. The overall objective of this project was to transfer work and knowledge that has been done on uncontrolled air flow in non-residential buildings in Florida to a national basis. This objective was implemented by means of four tasks: (1) Field testing and monitoring of uncontrolled air flow in a sample of New York buildings; (2) Detailed wall assembly laboratory measurements and modeling; (3) Whole building experiments and simulation of uncontrolled air flows; and (4) Develop and implement training on uncontrolled air flows for Practitioners in New York State.

  4. Residential outdoor air pollution and allergen sensitization in schoolchildren in Oslo, Norway

    NARCIS (Netherlands)

    Oftedal, B.; Brunekreef, B.; Nystad, W.; Nafstad, P.

    2007-01-01

    Background Epidemiological studies that have investigated the association between air pollution and atopy have found inconsistent results. Furthermore, often exposure to outdoor air pollution has had limited quality, and more individual exposure is needed. Objective To investigate the relations

  5. Quantification of emissions from domestic heating in residential areas of İzmir, Turkey and assessment of the impact on local/regional air-quality

    International Nuclear Information System (INIS)

    Sari, Deniz; Bayram, Abdurrahman

    2014-01-01

    Air pollution in cities is a major environmental problem principally in the developing countries. The quantification of emissions is a basic requirement to assess the human influence to the atmosphere. The air quality generally shows decreases with the major contribution residential emissions and meteorology in the winter season in the big cities. Poor meteorological conditions especially inversion events for the efficient mixing of air pollutants occurred during the winter months in İzmir. With this work we quantify the amount of domestic heating emissions for particulate matter (PM10), sulfur dioxides (SO 2 ), nitrogen dioxides (NO 2 ), volatile organic compounds (VOC) and carbon monoxide (CO) together with greenhouse gases which are carbon dioxide (CO 2 ), nitrous oxide (N 2 O) and methane (CH 4 ) in İzmir for 2008–2009 winter season. The results showed that the most affected residential areas were central districts in the city center from domestic heating emissions due to meteorological condition and demographic reasons. Air quality modeling is a great tool for assisting policy makers how to decrease emissions and improve air quality. At the second part of the study, calculated emissions were modeled by using CALMET/CALPUFF dispersion modeling system and plotted in the form of air pollution maps by using geographical information system to determine the locations and estimate the effects of the new residential areas that will be established in the future in İzmir. - Highlights: • The air pollution in cities especially shows raises with the opening of winter season. • Air pollution has become a problem due to rapid urbanization in İzmir, Turkey. • The air quality shows decreases with the residential emissions in İzmir's winter. • With this work we quantify the amount of domestic heating emissions for pollutants. • The impact of emissions on local air-quality is determined by using dispersion model

  6. Quantification of emissions from domestic heating in residential areas of İzmir, Turkey and assessment of the impact on local/regional air-quality

    Energy Technology Data Exchange (ETDEWEB)

    Sari, Deniz, E-mail: deniz.sari@tubitak.gov.tr [TUBITAK Marmara Research Center, Environment and Cleaner Production Institute, 41470 Kocaeli (Turkey); Bayram, Abdurrahman [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eylul University, Kaynaklar Campus, 35160 Buca, Izmir (Turkey)

    2014-08-01

    Air pollution in cities is a major environmental problem principally in the developing countries. The quantification of emissions is a basic requirement to assess the human influence to the atmosphere. The air quality generally shows decreases with the major contribution residential emissions and meteorology in the winter season in the big cities. Poor meteorological conditions especially inversion events for the efficient mixing of air pollutants occurred during the winter months in İzmir. With this work we quantify the amount of domestic heating emissions for particulate matter (PM10), sulfur dioxides (SO{sub 2}), nitrogen dioxides (NO{sub 2}), volatile organic compounds (VOC) and carbon monoxide (CO) together with greenhouse gases which are carbon dioxide (CO{sub 2}), nitrous oxide (N{sub 2}O) and methane (CH{sub 4}) in İzmir for 2008–2009 winter season. The results showed that the most affected residential areas were central districts in the city center from domestic heating emissions due to meteorological condition and demographic reasons. Air quality modeling is a great tool for assisting policy makers how to decrease emissions and improve air quality. At the second part of the study, calculated emissions were modeled by using CALMET/CALPUFF dispersion modeling system and plotted in the form of air pollution maps by using geographical information system to determine the locations and estimate the effects of the new residential areas that will be established in the future in İzmir. - Highlights: • The air pollution in cities especially shows raises with the opening of winter season. • Air pollution has become a problem due to rapid urbanization in İzmir, Turkey. • The air quality shows decreases with the residential emissions in İzmir's winter. • With this work we quantify the amount of domestic heating emissions for pollutants. • The impact of emissions on local air-quality is determined by using dispersion model.

  7. Development of residential solar air conditioning system for electricity power peak cut 3

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Gwon Jong [Korea Inst. of Energy and Resources, Daeduk (Korea, Republic of)

    1995-12-31

    In this research, the converter rectifier unit of the inverter air conditioner is substituted into the bidirectional PWM converter. The DC/DC power converter is established on the DC link between the photovoltaic array and the inverter air conditioner, and the photovoltaic air conditioning system which can be parallel driven which utility is developed. (author). 35 ref., 112 figs.

  8. Potential air toxics hot spots in truck terminals and cabs.

    Science.gov (United States)

    Smith, Thomas J; Davis, Mary E; Hart, Jaime E; Blicharz, Andrew; Laden, Francine; Garshick, Eric

    2012-12-01

    Hot spots are areas where concentrations of one or more air toxics--organic vapors or particulate matter (PM)--are expected to be elevated. The U.S. Environmental Protection Agency's (EPA*) screening values for air toxics were used in our definition of hot spots. According to the EPA, a screening value "is used to indicate a concentration of a chemical in the air to which a person could be continually exposed for a lifetime ... and which would be unlikely to result in a deleterious effect (either cancer or noncancer health effects)" (U.S. EPA 2006). Our characterization of volatile organic compounds (VOCs; namely 18 hydrocarbons, methyl tert-butyl ether [MTBE], acetone, and aldehydes) was added onto our ongoing National Cancer Institute-funded study of lung cancer and particulate pollutant concentrations (PM with an aerodynamic diameter highways. In Phase 1 of our study, 15 truck terminals across the United States were each visited for five consecutive days. During these site visits, sorbent tubes were used to collect 12-hour integrated samples of hydrocarbons and aldehydes from upwind and downwind fence-line locations as well as inside truck cabs. Meteorologic data and extensive site information were collected with each sample. In Phase 2, repeat visits to six terminals were conducted to test the stability of concentrations across time and judge the representativeness of our previous measurements. During the repeat site visits, the sampling procedure was expanded to include real-time sampling for total hydrocarbon (HC) and PM2.5 at the terminal upwind and downwind sites and inside the truck cabs, two additional monitors in the yard for four-quadrant sampling to better characterize the influence of wind, and indoor sampling in the loading dock and mechanic shop work areas. Mean and median concentrations of VOCs across the sampling locations in and around the truck terminals showed significant variability in the upwind concentrations as well as in the intensity of

  9. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    Science.gov (United States)

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  10. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  11. Air toxic emissions from burning of biomass globally-preliminary results

    International Nuclear Information System (INIS)

    Ward, D.E.; Hao, W.M.

    1992-01-01

    Emissions of trace gases, particles, and air toxic substances in the smoke plumes from biomass fires are of importance to global climate change. The potential impact of the air toxic emissions on the human population of specific regions globally is another major concern. The toxic materials are produced in high concentrations in areas of heavy biomass burning, e.g., Amazon Basin and Central/southern Africa. We provide new estimates of air toxics based on the combustion efficiency (percent of total carbon released as CO 2 ) for fires burning in different ecosystems on a global basis. Estimates of total biomass consumed on a global basis range from 2 to 10 Pg (1 petagram = 10 15 g) per year. We apply emission factors for various air toxics (g of emission released per kg of fuel consumed) to the estimate of global biomass consumption of 6.4 Pg per year. The principal air toxics analyzed in this paper include: Total particulate matter, CO, formaldehyde, acetaldehyde, acrolein, benzene, toluene, o-xylene, m, p-xylene, benzo[a]pyrene, and polycyclic organic material. The total emissions calculated for these materials on a yearly global basis are: 75, 362, 4.9, 1.5, 1.5, 2.1, 2.1, 0.3, 0.6, 0.001, 0.026, Tg (1 teragram = 10 12 g) per year, respectively. Biomass burning in the United States contributes less than 3% to the total global emissions

  12. Air toxics in Canada measured by the National Air Pollution Surveillance (NAPS) program and their relation to ambient air quality guidelines.

    Science.gov (United States)

    Galarneau, Elisabeth; Wang, Daniel; Dabek-Zlotorzynska, Ewa; Siu, May; Celo, Valbona; Tardif, Mylaine; Harnish, David; Jiang, Ying

    2016-02-01

    This study reports ambient concentrations of 63 air toxics that were measured in Canada by the National Air Pollution Surveillance (NAPS) program over the period 2009-2013. Measured concentrations are compared with ambient air quality guidelines from Canadian jurisdictions, and compounds that exceeded guidelines are identified and discussed. Although this study does not assess risk or cumulative effects, air toxics that approached guidelines are also identified so that their potential contribution to ambient air toxics pollution can be considered. Eleven air toxics exceeded at least one guideline, and an additional 16 approached guidelines during the study period. Four compounds were measured using methods whose detection limits exceeded a guideline value, three of which could not be compared with guidelines, since they were not detected in any samples. The assessment of several metal(loid) concentrations is tentative, since they were measured only in fine particulate matter (PM) but compared with guidelines based on coarse or total PM. Improvements to sampling and analysis techniques for the latter compounds as well as for those whose methods are subject to known uncertainties would improve confidence in reported concentrations and their relation to applicable guidelines. Analysis of sampling strategies for all compounds found to exceed or approach guidelines would contribute to ensuring that their spatiotemporal coverage is adequate. Examination of the air toxics not measured by NAPS but having guidelines in Canadian jurisdictions or being included in other programs such as the U.S. National-Scale Air Toxics Assessment (NATA) would contribute to ensuring that the full suite of pollutants relevant to ambient air quality in Canada is subject to adequate study. The results of this study can be applied to evaluating the effectiveness of toxic substances management in Canada. Recent measurements of 63 air toxics in Canada by the National Air Pollution Surveillance

  13. Bacterial community structures in air conditioners installed in Japanese residential buildings.

    Science.gov (United States)

    Hatayama, Kouta; Oikawa, Yurika; Ito, Hiroyuki

    2018-01-01

    The bacterial community structures in four Japanese split-type air conditioners were analyzed using a next-generation sequencer. A variety of bacteria were detected in the air filter of an air conditioner installed on the first floor. In the evaporator of this air conditioner, bacteria belonging to the genus Methylobacterium, or the family of Sphingomonadaceae, were predominantly detected. On the other hand, the majority of bacteria detected in the air filters and evaporators of air conditioners installed on the fifth and twelfth floors belonged to the family Enterobacteriaceae. The source of bacteria belonging to the family Enterobacteriaceae may have been aerosols generated by toilet flushing in the buildings. Our results suggested the possibility that the bacterial contamination in the air conditioners was affected by the floor level on which they were installed. The air conditioner installed on the lower floor, near the ground, may have been contaminated by a variety of outdoor bacteria, whereas the air conditioners installed on floors more distant from the ground may have been less contaminated by outdoor bacteria. However, these suppositions may apply only to the specific split-type air conditioners that we analyzed, because our sample size was small.

  14. Current Status of Air Toxics Management and Its Strategies for Controlling Emissions in Taiwan.

    Science.gov (United States)

    Tsai, Wen-Tien

    2016-04-12

    Since the 1970s, hazardous air pollutants (HAPs), so-called air toxics, have been of great concern because they can cause serious human health effects and have adverse effects on the environment. More noticeably, some of them are known to be human carcinogens. The objective of this paper is to investigate the regulatory systems and human health effects of air toxics which have been designated by the Taiwan government under the Air Pollution Control Act. These toxic air pollutants include acutely toxic gas ( i.e ., ammonia, chlorine, fluorides, hydrochloric acid, hydrogen cyanide, hydrogen sulfide, nitric acid, phosphoric acid and sulfuric acid), gas containing heavy metals, and carcinogenic chemicals (including formaldehyde, vinyl chloride, asbestos and matter containing asbestos, dioxins and furans, volatile organic compounds, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls). In line with international concern about the carcinogenic risk and environmental persistence of polychlorinated dibenzo- p -dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) and heavy metals in recent years, the current status in monitoring and reducing the emissions of PCDDs/PCDFs from stationary sources was analyzed as a case study in the present study. Furthermore, the control strategies for reducing emissions of air toxics from stationary sources in Taiwan were also addressed.

  15. Maryland air toxics regulation applicable to a natural gas compressor station

    International Nuclear Information System (INIS)

    Weidemann, H.A.; Hoffman, P.M.

    1992-01-01

    Columbia Gas Transmission Corporation submitted an air permit application to the Maryland Department of the Environment to construct a natural gas compressor station near Rutledge, Maryland. The station consists of three natural gas-fueled internal combustion reciprocating engines, each rated at 3200 horsepower. Maximum potential pollutant emissions associated with the station operation did not trigger Prevention of Significant Deterioration review or nonattainment area New Source review. However, a minor source air permit cannot be issued without addressing Maryland's toxic air regulations. Columbia initiated a detailed investigation of toxic air pollutants, including a stack test of an identical engine. Based on this information, the proposed station was subject to the toxic air regulation for acetaldehyde, acrolein, benzene, crotonaldehyde, and formaldehyde. Compliance with the toxic air regulation for crotonaldehyde was demonstrated by having an emission rate less than the threshold emission rate, specified in the regulation. The ambient air quality impact of the other four pollutants was determined using the Industrial Source Complex dispersion model and resulted in predicted concentrations below the pollutant-specific acceptable ambient level. A carcinogenic impact analysis was performed for acetaldehyde, benzene, and formaldehyde to demonstrate compliance with the accepted risk of one in one hundred thousand

  16. [On the question of occurrence and the problem of hygiene rating of fungal air pollution of the environment of residential and public buildings].

    Science.gov (United States)

    Gubernskiĭ, Iu D; Beliaeva, N N; Kalinina, N V; Mel'nikova, A I; Chuprina, O V

    2013-01-01

    Comprehensive sanitary examinations of fungal pollution of the environment of residential and public buildings were performed. There is established the occurrence of sensitization of the population associated with the fungal contamination of the wallings of buildings and presence of viable mold spores in the indoor air environment. Major factors determining the degree of fungal contamination of indoor environments: increasing humidity of indoor air due to leaks and bays, the area of enclosure structures and the temperature factor have been identified.

  17. Quantification of emissions from domestic heating in residential areas of İzmir, Turkey and assessment of the impact on local/regional air-quality.

    Science.gov (United States)

    Sari, Deniz; Bayram, Abdurrahman

    2014-08-01

    Air pollution in cities is a major environmental problem principally in the developing countries. The quantification of emissions is a basic requirement to assess the human influence to the atmosphere. The air quality generally shows decreases with the major contribution residential emissions and meteorology in the winter season in the big cities. Poor meteorological conditions especially inversion events for the efficient mixing of air pollutants occurred during the winter months in İzmir. With this work we quantify the amount of domestic heating emissions for particulate matter (PM10), sulfur dioxides (SO2), nitrogen dioxides (NO2), volatile organic compounds (VOC) and carbon monoxide (CO) together with greenhouse gases which are carbon dioxide (CO2), nitrous oxide (N2O) and methane (CH4) in İzmir for 2008-2009 winter season. The results showed that the most affected residential areas were central districts in the city center from domestic heating emissions due to meteorological condition and demographic reasons. Air quality modeling is a great tool for assisting policy makers how to decrease emissions and improve air quality. At the second part of the study, calculated emissions were modeled by using CALMET/CALPUFF dispersion modeling system and plotted in the form of air pollution maps by using geographical information system to determine the locations and estimate the effects of the new residential areas that will be established in the future in İzmir. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Formaldehyde: a candidate toxic air contaminant. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frye, B.; Parker, T.

    1988-03-01

    Formaldehyde (HCHO) is a gas widely used in adhesives and resins, textiles, embalming fluids, fungicides, air fresheners, and cosmetics. It is directly emitted into the ambient outdoor air from vehicular and stationary sources, and is also produced in the atmosphere from other substances by photochemical smog processes. The International Agency for Research on Cancer (IARC) has determined that there is sufficient evidence for carcinogenicity of formaldehyde to animals, and limited evidence for carcinogenicity to humans. EPA classifies formaldehyde as a probable human carcinogen with a one in a million risk concentration of 0.08 ppb.

  19. Indoor air-quality measurements in energy-efficient residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  20. Development of a solar-powered residential air conditioner: System optimization preliminary specification

    Science.gov (United States)

    Rousseau, J.; Hwang, K. C.

    1975-01-01

    Investigations aimed at the optimization of a baseline Rankine cycle solar powered air conditioner and the development of a preliminary system specification were conducted. Efforts encompassed the following: (1) investigations of the use of recuperators/regenerators to enhance the performance of the baseline system, (2) development of an off-design computer program for system performance prediction, (3) optimization of the turbocompressor design to cover a broad range of conditions and permit operation at low heat source water temperatures, (4) generation of parametric data describing system performance (COP and capacity), (5) development and evaluation of candidate system augmentation concepts and selection of the optimum approach, (6) generation of auxiliary power requirement data, (7) development of a complete solar collector-thermal storage-air conditioner computer program, (8) evaluation of the baseline Rankine air conditioner over a five day period simulating the NASA solar house operation, and (9) evaluation of the air conditioner as a heat pump.

  1. Dataset for Probabilistic estimation of residential air exchange rates for population-based exposure modeling

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset provides the city-specific air exchange rate measurements, modeled, literature-based as well as housing characteristics. This dataset is associated with...

  2. The Impact of Green Space Layouts on Microclimate and Air Quality in Residential Districts of Nanjing, China

    Directory of Open Access Journals (Sweden)

    Liyan Rui

    2018-04-01

    Full Text Available This study numerically investigates the influence of different vegetation types and layouts on microclimate and air quality in residential districts based on the morphology and green layout of Nanjing, China. Simulations were performed using Computational Fluid Dynamics and the microclimate model ENVI-met. Four green indices, i.e., the green cover ratio, the grass and shrub cover ratio, the ecological landscaping plot ratio and the landscaping isolation index, were combined to evaluate thermal and wind fields, as well as air quality in district models. Results show that under the same green cover ratio (i.e., the same quantity of all types of vegetation, the reduction of grass and shrub cover ratio (i.e., the quantity of grass and shrubs, replaced by trees, has an impact, even though small, on thermal comfort, wind speed and air pollution, and increases the leisure space for occupants. When trees are present, a low ecological landscaping plot ratio (which expresses the weight of carbon dioxide absorption and is larger in the presence of trees is preferable due to a lower blocking effect on wind and pollutant dispersion. In conjunction with a low landscaping plot ratio, a high landscaping isolation index (which means a distributed structure of vegetation enhances the capability of local cooling and the general thermal comfort, decreasing the average temperature up to about 0.5 °C and the average predicted mean vote (PMV up to about 20% compared with the non-green scenario. This paper shows that the relationship vegetation-microclimate-air quality should be analyzed taking into account not only the total area covered by vegetation but also its layout and degree of aggregation.

  3. Polycyclic Aromatic Hydrocarbons in Air and their Toxic Potency

    Indian Academy of Sciences (India)

    Among the urban air pollutants, polycyclic aromatic hydrocar- bons (P AHs) are a large group of over 100 different chemical compounds with 2 to 7 aromatic rings. Large quantities of such compounds are released into environment by various human activities. Recently PAHs in the environment have become.

  4. Toxic potency and effects of diffuse air pollution

    NARCIS (Netherlands)

    Hamers, T.H.M.

    2002-01-01

    Diffuse air pollution consists of an omnipresent complex mixture of pollutants that is emitted from many widely dispersed sources as traffic, industries, households, energy plants, waste incinerators, and agriculture. It can be deposited in relatively remote areas as a result of

  5. Risk of leukaemia and residential exposure to air pollution in an industrial area in Northern Italy: a case-control study.

    Science.gov (United States)

    Parodi, Stefano; Santi, Irene; Casella, Claudia; Puppo, Antonella; Montanaro, Fabio; Fontana, Vincenzo; Pescetto, Massimiliano; Stagnaro, Emanuele

    2015-01-01

    Leukaemia risk in adult populations exposed to environmental air pollution is poorly investigated. We have carried out a population-based case-control study in an area that included a fossil fuel power plant, a coke oven and two big chemical industries. Information on residential history and several risk factors for leukaemia was obtained from 164 cases, diagnosed between 2002 and 2005, and 279 controls. A higher risk for subjects residing in polluted areas was observed, but statistical significance was not reached (adjusted OR = 1.11 and 1.56 for subjects living in moderately and in heavily polluted zones, respectively, p = 0.190). Results suggest a possible aetiological role of residential air pollution from industrial sites on the risk of developing leukaemia in adult populations. However, the proportion of eligible subjects excluded from the study and the lack of any measure of air pollution prevent definitive conclusions from being drawn.

  6. Effect of heat recovery water heater system on the performance of residential split air conditioner using hydrocarbon refrigerant (HCR22)

    Science.gov (United States)

    Aziz, A.; Thalal; Amri, I.; Herisiswanto; Mainil, A. K.

    2017-09-01

    This This paper presents the performance of residential split air conditioner (RSAC) using hydrocarbon refrigerant (HCR22) as the effect on the use of heat recovery water heater system (HRWHS). In this study, RSAC was modified with addition of dummy condenser (trombone coil type) as heat recovery water heater system (HRWHS). This HRWHS is installed between a compressor and a condenser by absorbing a part of condenser waste heat. The results show that RSAC with HRWHS is adequate to generate hot water with the temperature range about 46.58˚C - 48.81˚C when compared to without HRWHS and the use of dummy condenser does not give significant effect to the split air conditioner performance. When the use of HRWHS, the refrigerant charge has increase about 19.05%, the compressor power consumption has slightly increase about 1.42% where cooling capacity almost the same with slightly different about 0.39%. The condenser heat rejection is lower about 2.68% and the COP has slightly increased about 1.05% when compared to without HRWHS. The use of HRWHS provide free hot water, it means there is energy saving for heating water without negative impact to the system performance of RSAC.

  7. Effects of climate change on residential infiltration and air pollution exposure.

    Science.gov (United States)

    Ilacqua, Vito; Dawson, John; Breen, Michael; Singer, Sarany; Berg, Ashley

    2017-01-01

    Air exchange through infiltration is driven partly by indoor/outdoor temperature differences, and as climate change increases ambient temperatures, such differences could vary considerably even with small ambient temperature increments, altering patterns of exposures to both indoor and outdoor pollutants. We calculated changes in air fluxes through infiltration for prototypical detached homes in nine metropolitan areas in the United States (Atlanta, Boston, Chicago, Houston, Los Angeles, Minneapolis, New York, Phoenix, and Seattle) from 1970-2000 to 2040-2070. The Lawrence Berkeley National Laboratory model of infiltration was used in combination with climate data from eight regionally downscaled climate models from the North American Regional Climate Change Assessment Program. Averaged over all study locations, seasons, and climate models, air exchange through infiltration would decrease by ~5%. Localized increased infiltration is expected during the summer months, up to 20-30%. Seasonal and daily variability in infiltration are also expected to increase, particularly during the summer months. Diminished infiltration in future climate scenarios may be expected to increase exposure to indoor sources of air pollution, unless these ventilation reductions are otherwise compensated. Exposure to ambient air pollution, conversely, could be mitigated by lower infiltration, although peak exposure increases during summer months should be considered, as well as other mechanisms.

  8. Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

    Science.gov (United States)

    Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J

    2015-12-01

    Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems. © 2014 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.

  9. Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project)

    DEFF Research Database (Denmark)

    Asikainen, Arja; Carrer, Paolo; Kephalopoulos, Stylianos

    2016-01-01

    ), approximately 90 % of EU citizens live in areas where the World Health Organization (WHO) guidelines for air quality of particulate matter sized PM2.5) are not met. Since sources of pollution reside in both indoor and outdoor air, selecting the most appropriate ventilation strategy is not a simple...... matter (PM2.5), outdoor bioaerosols, volatile organic compounds (VOC), carbon oxide (CO) radon and dampness was estimated. The analysis was based on scenario comparison, using an outdoor-indoor mass-balance model and varying the ventilation rates. Health effects were estimated with burden of diseases (Bo...... air; and (iii) indoor source control, showed that all three approaches are able to provide substantial reductions in the health risks, varying from approximately 20 % to 44 %, corresponding to 400 000 and 900 000 saved healthy life years in EU-26. PM2.5 caused majority of the health effects in all...

  10. Comparing land use regression and dispersion modelling to assess residential exposure to ambient air pollution for epidemiological studies.

    Science.gov (United States)

    de Hoogh, Kees; Korek, Michal; Vienneau, Danielle; Keuken, Menno; Kukkonen, Jaakko; Nieuwenhuijsen, Mark J; Badaloni, Chiara; Beelen, Rob; Bolignano, Andrea; Cesaroni, Giulia; Pradas, Marta Cirach; Cyrys, Josef; Douros, John; Eeftens, Marloes; Forastiere, Francesco; Forsberg, Bertil; Fuks, Kateryna; Gehring, Ulrike; Gryparis, Alexandros; Gulliver, John; Hansell, Anna L; Hoffmann, Barbara; Johansson, Christer; Jonkers, Sander; Kangas, Leena; Katsouyanni, Klea; Künzli, Nino; Lanki, Timo; Memmesheimer, Michael; Moussiopoulos, Nicolas; Modig, Lars; Pershagen, Göran; Probst-Hensch, Nicole; Schindler, Christian; Schikowski, Tamara; Sugiri, Dorothee; Teixidó, Oriol; Tsai, Ming-Yi; Yli-Tuomi, Tarja; Brunekreef, Bert; Hoek, Gerard; Bellander, Tom

    2014-12-01

    Land-use regression (LUR) and dispersion models (DM) are commonly used for estimating individual air pollution exposure in population studies. Few comparisons have however been made of the performance of these methods. Within the European Study of Cohorts for Air Pollution Effects (ESCAPE) we explored the differences between LUR and DM estimates for NO2, PM10 and PM2.5. The ESCAPE study developed LUR models for outdoor air pollution levels based on a harmonised monitoring campaign. In thirteen ESCAPE study areas we further applied dispersion models. We compared LUR and DM estimates at the residential addresses of participants in 13 cohorts for NO2; 7 for PM10 and 4 for PM2.5. Additionally, we compared the DM estimates with measured concentrations at the 20-40 ESCAPE monitoring sites in each area. The median Pearson R (range) correlation coefficients between LUR and DM estimates for the annual average concentrations of NO2, PM10 and PM2.5 were 0.75 (0.19-0.89), 0.39 (0.23-0.66) and 0.29 (0.22-0.81) for 112,971 (13 study areas), 69,591 (7) and 28,519 (4) addresses respectively. The median Pearson R correlation coefficients (range) between DM estimates and ESCAPE measurements were of 0.74 (0.09-0.86) for NO2; 0.58 (0.36-0.88) for PM10 and 0.58 (0.39-0.66) for PM2.5. LUR and dispersion model estimates correlated on average well for NO2 but only moderately for PM10 and PM2.5, with large variability across areas. DM predicted a moderate to large proportion of the measured variation for NO2 but less for PM10 and PM2.5. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Ambient air pollution exposure, residential mobility and term birth weight in Oslo, Norway.

    NARCIS (Netherlands)

    Madsen, C.; Gehring, U.; Walker, S.K.; Brunekreef, B.; Stigum, H.; Naess, O.; Nafstad, P.

    2010-01-01

    Environmental exposure during pregnancy may have lifelong health consequences for the offspring and some studies have association between maternal exposure to air pollution during pregnancy and offspring's birth weight. However, many of these studies do not take into account small-scale variations

  12. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  13. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A. [ABT Systems, LLC, Annville, PA (United States); Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  14. Integrated Management of Residential Indoor Air Quality: A Call for Stakeholders in a Changing Climate.

    Science.gov (United States)

    Levasseur, Marie-Eve; Poulin, Patrick; Campagna, Céline; Leclerc, Jean-Marc

    2017-11-25

    A paradigm change in the management of environmental health issues has been observed in recent years: instead of managing specific risks individually, a holistic vision of environmental problems would assure sustainable solutions. However, concrete actions that could help translate these recommendations into interventions are lacking. This review presents the relevance of using an integrated indoor air quality management approach to ensure occupant health and comfort. At the nexus of three basic concepts (reducing contaminants at the source, improving ventilation, and, when relevant, purifying the indoor air), this approach can help maintain and improve indoor air quality and limit exposure to several contaminants. Its application is particularly relevant in a climate change context since the evolving outdoor conditions have to be taken into account during building construction and renovation. The measures presented through this approach target public health players, building managers, owners, occupants, and professionals involved in building design, construction, renovation, and maintenance. The findings of this review will help the various stakeholders initiate a strategic reflection on the importance of indoor air quality and climate change issues for existing and future buildings. Several new avenues and recommendations are presented to set the path for future research activities.

  15. Investigation of indoor air quality at residential homes in Hong Kong - case study

    International Nuclear Information System (INIS)

    Shun Cheng Lee; Waiming Li; Chiohang Ao

    2002-01-01

    Indoor air quality (IAQ) has been a matter of public concern in Hong Kong. Recently, the Hong Kong Government has recognized the potential risk and problems related to indoor air pollution, and it is striving to establish IAQ objectives for different types of indoor environments. This study attempts to provide more information about the present IAQ of local resident flats. Air pollutants measured in this study included carbon dioxide (CO 2 ), respirable suspended particulate matter (PM 10 ), formaldehyde (HCHO), volatile organic compounds (VOCs) and airborne bacteria. The results of this study indicate that the 8-h average concentrations of CO 2 and PM 10 in the domestic kitchens investigated were 14% and 67% higher than those measured in the living rooms. The indoor air pollution caused by PM 10 was more serious in domestic kitchens than in living rooms as almost all of the kitchens investigated had higher indoor levels of PM 10 . The majority of the domestic living rooms and kitchens studied had average concentrations of airborne bacteria higher than 500CFU/m 3 . The mean total bacteria count recorded in kitchens was greater than that obtained in living rooms by 23%. In homes where occupants smoke, the negative impact of benzene, toluene and m,p-xylene on the IAQ was greatly enhanced. The use of liquefied petroleum gas (LPG) stove has more significant impact on indoor VOCs than the use of cooking stoves with natural gas as cooking fuel. (Author)

  16. Predicting residential air exchange rates from questionnaires and meteorology: model evaluation in central North Carolina.

    Science.gov (United States)

    Breen, Michael S; Breen, Miyuki; Williams, Ronald W; Schultz, Bradley D

    2010-12-15

    A critical aspect of air pollution exposure models is the estimation of the air exchange rate (AER) of individual homes, where people spend most of their time. The AER, which is the airflow into and out of a building, is a primary mechanism for entry of outdoor air pollutants and removal of indoor source emissions. The mechanistic Lawrence Berkeley Laboratory (LBL) AER model was linked to a leakage area model to predict AER from questionnaires and meteorology. The LBL model was also extended to include natural ventilation (LBLX). Using literature-reported parameter values, AER predictions from LBL and LBLX models were compared to data from 642 daily AER measurements across 31 detached homes in central North Carolina, with corresponding questionnaires and meteorological observations. Data was collected on seven consecutive days during each of four consecutive seasons. For the individual model-predicted and measured AER, the median absolute difference was 43% (0.17 h(-1)) and 40% (0.17 h(-1)) for the LBL and LBLX models, respectively. Additionally, a literature-reported empirical scale factor (SF) AER model was evaluated, which showed a median absolute difference of 50% (0.25 h(-1)). The capability of the LBL, LBLX, and SF models could help reduce the AER uncertainty in air pollution exposure models used to develop exposure metrics for health studies.

  17. [Methodical problems of monitoring of fine particulate matters in atmospheric air of residential areas].

    Science.gov (United States)

    Karelin, A O; Lomtev, A Yu; Mozzhukhina, N A; Yeremin, G B; Nikonov, V A

    Inhalation of fine particulate matters (PM and PM ) poses a threat for the health of population. Purpose of the study the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint-Petersburg and identification of the main problems of the monitoring. Research methods methods of scientific hypothetical deductive cognition, sanitary-statistical methods, general logical methods and approaches of researches: analysis, synthesis, abstracting, generalization, induction. Results. The article represents the analysis of the monitoring of fine particulate matters in the atmospheric air of Saint- Petersburg. Only 11 in automatic monitoring stations out of 22 there is carried out the control of fine particulate matters: in 7 - PM and PM, and in 4 - PM The average year concentrations were below MAC in all the stations. The maximum concentrations achieved 3 MAC, but the repeatance of cases of exceedence of concentrations more than MAC was very rare. On the average of the city concentrations of PM were decreased from 0,8 MAC in 2006 and 1,1 MAC in 2007 to 0,5 MAC in 2013-14. The executed analysis revealed main problems of the monitoring of fine particulate matters in the Russian Federation. They include the absence of the usage 1of the officially approved methods of controlling of PM and PM in the atmospheric air until March 1, 2016, lack of the modern equipment for measurement of fine particulate matters. Conclusions. Therefore, the state of the monitoring of fine particulate matters in the atmospheric air in the Russian Federation fails to be satisfactory. It is necessary to improve system of the monitoring, create modern Russian appliances, methods and means for measurement of fine particulate matters concentrations in the atmospheric air.

  18. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    Directory of Open Access Journals (Sweden)

    Silvia Cocchi

    2013-01-01

    Full Text Available The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling, through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

  19. Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barley, C. D.; Anderson, R.; Hendron, B.; Hancock, E.

    2007-12-01

    This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

  20. Air toxic emissions from the combustion of coal: Identifying and quantifying hazardous air pollutants from US coals

    Energy Technology Data Exchange (ETDEWEB)

    Szpunar, C.B.

    1992-09-01

    This report addresses the key air toxic emissions likely to emanate from continued and expanded use of domestic coal. It identifies and quantifies those trace elements specified in the US 1990 Clean Air Act Amendments, by tabulating selected characterization data on various source coals by region, state, and rank. On the basis of measurements by various researchers, this report also identifies those organic compounds likely to be derived from the coal combustion process (although their formation is highly dependent on specific boiler configurations and operating conditions).

  1. Air toxic emissions from the combustion of coal: Identifying and quantifying hazardous air pollutants from US coals

    International Nuclear Information System (INIS)

    Szpunar, C.B.

    1992-09-01

    This report addresses the key air toxic emissions likely to emanate from continued and expanded use of domestic coal. It identifies and quantifies those trace elements specified in the US 1990 Clean Air Act Amendments, by tabulating selected characterization data on various source coals by region, state, and rank. On the basis of measurements by various researchers, this report also identifies those organic compounds likely to be derived from the coal combustion process (although their formation is highly dependent on specific boiler configurations and operating conditions)

  2. Emission of toxic air pollutants from biomass combustion

    International Nuclear Information System (INIS)

    Houck, J.E.; Barnett, S.G.; Roholt, R.B.; Rock, M.E.

    1991-01-01

    Combustion of biomass for power generation, home heating, process steam generation, and waste disposal constitutes a major source of air pollutants nationwide. Emissions from hog-fueled boilers, demolition wood-fired power plants, municipal waste incinerators, woodstoves, fireplaces, pellet stoves, agricultural burning, and forestry burning have been characterized for a variety of purposes. These have included risk assessment, permitting, emission inventory development, source profiling for receptor modeling, and control technology evaluations. From the results of the source characterization studies a compilation of emission factors for criteria and non-criteria pollutants are presented here. Key among these pollutants are polycyclic aromatic hydrocarbons, priority pollutant metals, carbon monoxide, sulfur dioxide, nitrous oxides, and PM 10 particles. The emission factors from the biomass combustion processes are compared and contrasted with other pollutant sources. In addition, sampling and analysis procedures most appropriate for characterizing emissions from the biomass combustion sources are also discussed

  3. Air toxics being measured more accurately, controlled more effectively

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    In response to the directives of the Clean Air Act Amendments, Argonne National Laboratory is developing new or improved pollutant control technologies for industries that burn fossil fuels. This research continues Argonne`s traditional support for the US DOE Flue Gas Cleanup Program. Research is underway to measure process emissions and identify new and improved control measures. Argonne`s emission control research has ranged from experiments in the basic chemistry of pollution-control systems, through laboratory-scale process development and testing to pilot-scale field tests of several technologies. Whenever appropriate, the work has emphasized integrated or combined control systems as the best approach to technologies that offer low cost and good operating characteristics.

  4. Air toxics evaluation for a nuclear power plant

    International Nuclear Information System (INIS)

    Lokey, D.; Orr, W.

    1994-01-01

    An emission inventory of nonradiological hazardous air pollutants (HAP) was prepared for TVA's Browns Ferry Nuclear Plant (BFN). The purpose of this effort was to determine whether BFN is a major HAP emission source. About 40 specific HAP were identified in products used at FBN. HAP emission totals from BFN were estimated at 6 T/Y, well below the major-source cutoff. Off-site waste disposal reduced gross emission estimates by about 8 percent. HAP emission evaluation by product categories showed the largest portion due to paints and coatings, followed by cleaning compounds. HAP emission breakdown by chemical species showed xylene to be the predominate HAP emitted, followed by methyl ethyl ketone

  5. Air quality monitoring at toxic waste sites: A Hanford perspective

    International Nuclear Information System (INIS)

    Laws, G.L.; Glantz, C.S.

    1989-10-01

    Air quality monitoring is being conducted as part of remedial investigation activities at waste sites in the 1100-EM-1 Operating Unit at the US Department of Energy's Hanford Site. Sampling is being conducted for volatile organic compounds (VOCs), semivolatile organic compounds (SVOCs) (including pesticides and PCBs), metals, and asbestos. The monitoring program is being conducted in three phases: before, during, and after intrusive remedial investigation activities. At each waste site, battery-powered monitoring equipment is positioned at one location upwind of the site (to measure background concentrations of pollutants) and typically at two locations downwind of the site. Control samples are used to identify sample contamination that may occur during handling or analysis. All samples are analyzed using methods approved by the US Environmental Protection Agency. The results from the first phase of sampling have been assessed and are being used to upgrade sampling and laboratory analysis procedures. 5 refs

  6. Organochlorine pesticides in ambient air in selected urban and rural residential areas in the Philippines derived from passive samplers with polyurethane disks.

    Science.gov (United States)

    Santiago, Evangeline C; Cayetano, Mylene G

    2011-01-01

    The passive sampler with PUF disk was applied to investigate the types and concentrations of organochlorine pesticides (OCPs) in ambient air in three urban and rural residential areas simultaneously at different weather conditions in the Philippines. The concentrations of OCPs derived from the passive samplers indicated clear distinctions in the predominance of certain types and amounts of OCPs in air at different sampling sites and periods of sampling. Chlordanes were detected in concentrations ranging from 218 to 2,324 pg/m³ in the urban residential sites in all the sampling periods, indicating the possible use of these pesticides as termiticides in houses. Endosulfans were detected in two rural sites at 491 pg/m³ and 904 pg/m³ during one sampling period; indicating the possible use of the pesticide in the farm areas at that period.

  7. Personal and ambient exposures to air toxics in Camden, New Jersey.

    Science.gov (United States)

    Lioy, Paul J; Fan, Zhihua; Zhang, Junfeng; Georgopoulos, Panos; Wang, Sheng-Wei; Ohman-Strickland, Pamela; Wu, Xiangmei; Zhu, Xianlei; Harrington, Jason; Tang, Xiaogang; Meng, Qingyu; Jung, Kyung Hwa; Kwon, Jaymin; Hernandez, Marta; Bonnano, Linda; Held, Joann; Neal, John

    2011-08-01

    Personal exposures and ambient concentrations of air toxics were characterized in a pollution "hot spot" and an urban reference site, both in Camden, New Jersey. The hot spot was the city's Waterfront South neighborhood; the reference site was a neighborhood, about 1 km to the east, around the intersection of Copewood and Davis streets. Using personal exposure measurements, residential ambient air measurements, statistical analyses, and exposure modeling, we examined the impact of local industrial and mobile pollution sources, particularly diesel trucks, on personal exposures and ambient concentrations in the two neighborhoods. Presented in the report are details of our study design, sample and data collection methods, data- and model-analysis approaches, and results and key findings of the study. In summary, 107 participants were recruited from nonsmoking households, including 54 from Waterfront South and 53 from the Copewood-Davis area. Personal air samples were collected for 24 hr and measured for 32 target compounds--11 volatile organic compounds (VOCs*), four aldehydes, 16 polycyclic aromatic hydrocarbons (PAHs), and particulate matter (PM) with an aerodynamic diameter 0.6) was found between benzene and MTBE in both locations. These results suggest that automobile exhausts were the main contributors to benzene and MTBE air pollution in both neighborhoods. Formaldehyde and acetaldehyde concentrations were found to be high in both neighborhoods. Mean (+/- SD) concentrations of formaldehyde were 20.2 +/- 19.5 microg/m3 in Waterfront South and 24.8 +/- 20.8 microg/m3 in Copewood-Davis. A similar trend was observed for the two compounds during the saturation-sampling campaigns. The results indicate that mobile sources (i.e., diesel trucks) had a large impact on formaldehyde and acetaldehyde concentrations in both neighborhoods and that both are aldehyde hot spots. The study also showed that PM2.5, aldehydes, BTEX, and MTBE concentrations in both Waterfront South

  8. Residential proximity to major roads and term low birth weight: the roles of air pollution, heat, noise, and road-adjacent trees.

    Science.gov (United States)

    Dadvand, Payam; Ostro, Bart; Figueras, Francesc; Foraster, Maria; Basagaña, Xavier; Valentín, Antònia; Martinez, David; Beelen, Rob; Cirach, Marta; Hoek, Gerard; Jerrett, Michael; Brunekreef, Bert; Nieuwenhuijsen, Mark J

    2014-07-01

    Maternal residential proximity to roads has been associated with adverse pregnancy outcomes. However, there is no study investigating mediators or buffering effects of road-adjacent trees on this association. We investigated the association between mothers' residential proximity to major roads and term low birth weight (LBW), while exploring possible mediating roles of air pollution (PM(2.5), PM(2.5-10), PM(10), PM(2.5) absorbance, nitrogen dioxide, and nitrogen oxides), heat, and noise and buffering effect of road-adjacent trees on this association. This cohort study was based on 6438 singleton term births in Barcelona, Spain (2001-2005). Road proximity was measured as both continuous distance to and living within 200 m from a major road. We assessed individual exposures to air pollution, noise, and heat using, respectively, temporally adjusted land-use regression models, annual averages of 24-hour noise levels across 50 m and 250 m, and average of satellite-derived land-surface temperature in a 50-m buffer around each residential address. We used vegetation continuous fields to abstract tree coverage in a 200-m buffer around major roads. Living within 200 m of major roads was associated with a 46% increase in term LBW risk; an interquartile range increase in heat exposure with an 18% increase; and third-trimester exposure to PM(2.5), PM(2.5-10), and PM10 with 24%, 25%, and 26% increases, respectively. Air pollution and heat exposures together explained about one-third of the association between residential proximity to major roads and term LBW. Our observations on the buffering of this association by road-adjacent trees were not consistent between our 2 measures of proximity to major roads. An increased risk of term LBW associated with proximity to major roads was partly mediated by air pollution and heat exposures.

  9. Innovative technologies for removing toxic compounds from groundwater and air

    International Nuclear Information System (INIS)

    Rosocha, L.A.; Allen, G.R.; Anderson, G.K.; Bechtold, L.A.; Coogan, J.J.; Heck, H.G.; Kang, M.; McCulla, W.H.; Secker, D.A.; Smith, J.D.; Tennant, R.A.; Wantuck, P.J.

    1992-01-01

    Innovative waste treatment technologies are being developed to remove hazardous organic wastes from water and air. These technologies involve the generation of highly reactive free radicals and their reaction with organic compounds. Two efficient methods of producing these reactive free radicals are radiolysis and electrical-discharge plasmas. Radiolytic technology involves the irradiation of contaminated media with high-energy electron beams or x rays generated from the beams (megavolt energies, hundreds of kilorad doses). This process is best understood in aqueous solutions, in which sizable quantities of the free radicals e aq - , OH*, and H*, as well as the more stable oxidant H 2 0 2 , are produced. These highly reactive species react with organic contaminants to produce C0 2 , H 2 0, and salts, which are no longer hazardous. Nonequilibrium electrical-discharge plasmas involve the generation of copious quantities of reactive free radicals from the dissociation of molecular oxygen by energetic electrons in the gas-based discharge. One of the most promising technologies for plasma processing is based upon the ''silent electrical discharge'' that has proven to be industrially dependable for the generation of large quantities of ozone

  10. Excretory nitrogen metabolism and defence against ammonia toxicity in air-breathing fishes.

    Science.gov (United States)

    Chew, S F; Ip, Y K

    2014-03-01

    With the development of air-breathing capabilities, some fishes can emerge from water, make excursions onto land or even burrow into mud during droughts. Air-breathing fishes have modified gill morphology and morphometry and accessory breathing organs, which would tend to reduce branchial ammonia excretion. As ammonia is toxic, air-breathing fishes, especially amphibious ones, are equipped with various strategies to ameliorate ammonia toxicity during emersion or ammonia exposure. These strategies can be categorized into (1) enhancement of ammonia excretion and reduction of ammonia entry, (2) conversion of ammonia to a less toxic product for accumulation and subsequent excretion, (3) reduction of ammonia production and avoidance of ammonia accumulation and (4) tolerance of ammonia at cellular and tissue levels. Active ammonia excretion, operating in conjunction with lowering of ambient pH and reduction in branchial and cutaneous NH₃ permeability, is theoretically the most effective strategy to maintain low internal ammonia concentrations. NH₃ volatilization involves the alkalization of certain epithelial surfaces and requires mechanisms to prevent NH₃ back flux. Urea synthesis is an energy-intensive process and hence uncommon among air-breathing teleosts. Aestivating African lungfishes detoxify ammonia to urea and the accumulated urea is excreted following arousal. Reduction in ammonia production is achieved in some air-breathing fishes through suppression of amino acid catabolism and proteolysis, or through partial amino acid catabolism leading to alanine formation. Others can slow down ammonia accumulation through increased glutamine synthesis in the liver and muscle. Yet, some others develop high tolerance of ammonia at cellular and tissue levels, including tissues in the brain. In summary, the responses of air-breathing fishes to ameliorate ammonia toxicity are many and varied, determined by the behaviour of the species and the nature of the environment in

  11. Air pollution from residential wood combustion in a Danish village. Measuring campaign and analysis of results

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, P.; Roerdam Olesen, H.; Bossi, R.; Stubkjaer, J.

    2010-05-15

    A campaign took place in the winter 2006/2007 comprising measurements of many air pollution components at two sites: a wood smoke exposed site within the village Slagslunde, and a background site 500 m outside of the village. The report describes the campaign and its results. A central result is a so-called 'wood smoke source profile', which relates several measures of wood smoke pollution to each other. This is based on a 'cleaned' data set, for which the effect of other sources than wood smoke was small. The wood smoke profile links the measures PM2.5, particle volume, soot, monosaccharide anhydrides (levoglucosan and mannosan) and different PAHs to each other. Particle number N does not have a close link to the other measures. (author)

  12. Evaluating the Spatial Distribution of Toxic Air Contaminants in Multiple Ecosystem Indicators in the Sierra Nevada-Southern Cascades

    Science.gov (United States)

    Nanus, L.; Simonich, S. L.; Rocchio, J.; Flanagan, C.

    2013-12-01

    Toxic air contaminants originating from agricultural areas of the Central Valley in California threaten vulnerable sensitive receptors including surface water, vegetation, snow, sediments, fish, and amphibians in the Sierra Nevada-Southern Cascades region. The spatial distribution of toxic air contaminants in different ecosystem indicators depends on variation in atmospheric concentrations and deposition, and variation in air toxics accumulation in ecosystems. The spatial distribution of organic air toxics and mercury at over 330 unique sampling locations and sample types over two decades (1990-2009) in the Sierra Nevada-Southern Cascades region were compiled and maps were developed to further understand spatial patterns and linkages between air toxics deposition and ecological effects. Potential ecosystem impacts in the Sierra Nevada-Southern Cascades region include bioaccumulation of air toxics in both aquatic and terrestrial ecosystems, reproductive disruption, and immune suppression. The most sensitive ecological end points in the region that are affected by bioaccumulation of toxic air contaminants are fish. Mercury was detected in all fish and approximately 6% exceeded human consumption thresholds. Organic air toxics were also detected in fish yielding variable spatial patterns. For amphibians, which are sensitive to pesticide exposure and potential immune suppression, increasing trends in current and historic use pesticides are observed from north to south across the region. In other indicators, such as vegetation, pesticide concentrations in lichen increase with increasing elevation. Current and historic use pesticides and mercury were also observed in snowpack at high elevations in the study area. This study shows spatial patterns in toxic air contaminants, evaluates associated risks to sensitive receptors, and identifies data gaps. Future research on atmospheric modeling and information on sources is needed in order to predict which ecosystems are the

  13. Use of Segregation Indices, Townsend Index, and Air Toxics Data to Assess Lifetime Cancer Risk Disparities in Metropolitan Charleston, South Carolina, USA

    Directory of Open Access Journals (Sweden)

    LaShanta J. Rice

    2014-05-01

    Full Text Available Background: Studies have demonstrated a relationship between segregation and level of education, occupational opportunities, and risk behaviors, yet a paucity of research has elucidated the association between racial residential segregation, socioeconomic deprivation, and lifetime cancer risk. Objectives: We examined estimated lifetime cancer risk from air toxics by racial composition, segregation, and deprivation in census tracts in Metropolitan Charleston. Methods: Segregation indices were used to measure the distribution of groups of people from different races within neighborhoods. The Townsend Index was used to measure economic deprivation in the study area. Poisson multivariate regressions were applied to assess the association of lifetime cancer risk with segregation indices and Townsend Index along with several sociodemographic measures. Results: Lifetime cancer risk from all pollution sources was 28 persons/million for half of the census tracts in Metropolitan Charleston. Isolation Index and Townsend Index both showed significant correlation with lifetime cancer risk from different sources. This significance still holds after adjusting for other sociodemographic measures in a Poisson regression, and these two indices have stronger effect on lifetime cancer risk compared to the effects of sociodemographic measures. Conclusions: We found that material deprivation, measured by the Townsend Index and segregation measured by the Isolation index, introduced high impact on lifetime cancer risk by air toxics at the census tract level.

  14. Air quality and residential wood combustion - application of the model system SIMAIRrwc for some Swedish municipalities; Luftkvalitet och smaaskalig biobraensleeldning. Tillaempningar av SIMAIRved foer naagra kommuner

    Energy Technology Data Exchange (ETDEWEB)

    Omstedt, Gunnar; Andersson, Stefan; Johansson, Christer; Loefgren, Bengt-Erik

    2008-11-15

    SIMAIRrwc is a Web based evaluation tool for meeting the EU directive on air pollution limits in residential areas using wood combustion. The background is a four-year research program (2001-2004) called Biomass Combustion Health and Environment. Some conclusions from this program were that emissions from small scale wood combustion can influence human health mainly due to high emitting old wood stoves during cold weather conditions and that the air quality in such areas can improve significantly if old wood stoves were replaced by modern wood boilers attached to a storage tank or with a pellet boiler. SIMAIRrwc is based on the same principles as SIMAIRroad, which is a Web based evaluation tool for road traffic i.e. coupled model system using different models on local, urban and regional geographical scales, best available emission data, but at the same time presented in a very simplified way. In this project SIMAIRrwc has been applied in five different Swedish municipalities. The aim has been to apply and improve the model in cooperation with the municipalities. The conclusions from the project are: Small scale wood combustions in residential areas are local problems which sometimes include only a few houses and/or wood-burners. Air quality problems related to the EU directive are mainly due to particles. Combinations of residential areas with wood combustion and emissions from nearby dense traffic roads might give rise to bad air quality. Actions require knowledge about individual equipment which needs information from the local chimney sweeps. The best way to identify problem areas is to use model calculations. If model calculations indicate risks of exceeding air quality limits, then new calculations should be made with improved input data taking into account for example information of district heating or other installations that can effect the emissions. Before actions are taken it may also be useful to make measurements. The measurement site can then be

  15. A Bayesian kriging model for estimating residential exposure to air pollution of children living in a high-risk area in Italy

    Directory of Open Access Journals (Sweden)

    Ana M. Vicedo-Cabrera

    2013-11-01

    Full Text Available A core challenge in epidemiological analysis of the impact of exposure to air pollution on health is assessment of the individual exposure for subjects at risk. Geographical information systems (GIS-based pollution mapping, such as kriging, has become one of the main tools for evaluating individual exposure to ambient pollutants. We applied universal Bayesian kriging to estimate the residential exposure to gaseous air pollutants for children living in a high-risk area (Milazzo- Valle del Mela in Sicily, Italy. Ad hoc air quality monitoring campaigns were carried out: 12 weekly measurements for sulphur dioxide (SO2 and nitrogen dioxide (NO2 were obtained from 21 passive dosimeters located at each school yard of the study area from November 2007 to April 2008. Universal Bayesian kriging was performed to predict individual exposure levels at each residential address for all 6- to 12-years-old children attending primary school at various locations in the study area. Land use, altitude, distance to main roads and population density were included as covariates in the models. A large geographical heterogeneity in air quality was recorded suggesting complex exposure patterns. We obtained a predicted mean level of 25.78 (±10.61 μg/m3 of NO2 and 4.10 (±2.71 μg/m3 of SO2 at 1,682 children’s residential addresses, with a normalised root mean squared error of 28% and 25%, respectively. We conclude that universal Bayesian kriging approach is a useful tool for the assessment of realistic exposure estimates with regard to ambient pollutants at home addresses. Its prediction uncertainty is highly informative and can be used for both designing subsequent campaigns and for improved modelling of epidemiological associations.

  16. Pollution of atmospheric air with toxic and radioactive particulate matter investigated by means of nuclear techniques

    International Nuclear Information System (INIS)

    Jagielak, J.

    1978-01-01

    The application of spectrometric methods of nuclear techniques to the investigations of atmospheric air pollution by toxic and radioactive elements and results of these investigations conducted in the highly industrialized and urbanized regions of Poland have been presented. The method of precipitation of the samples, the measurements and analysis of radiation spectra of alpha and gamma radiation emitted by isotopes present in the samples have been described. The concentrations of toxic metal dust in the air have been evaluated by neutron activation and X-ray fluorescence analysis. Appropriate methods of measurement, calibration of instrument and the discussion of results have been presented. The work presents the results of investigations performed in Siersza within the years 1973-1974 and in Warsaw in the period of 1975-1977, which have permitted to estimate the mean monthly values of concentration in the atmospheric air of the following radioisotopes: 7 Be, 54 Mn, 95 Zr, 103 Ru, 106 Ru, 125 Sb, 131 I, 137 Cs, 140 Ba, 141 Ce, 144 Ce, 226 Ra, Th-nat, U-nat and the following stable elements: Sc, Cr, Fe, Co, Zn, As, Se, Sb, W, Pb. The analysis of changes in concentration of each particular artificial radioisotope in the air for the region of Poland in connection with Chinese nuclear explosions have been given. On the basis of the performed environmental investigations the method of analysis of relations between the concentrations of particular elements present in the dust has been discussed. The applications of this method have been presented. The hazard to the population and the environment caused by the radioactive and toxic dust present in the atmospheric air has been estimated. (author)

  17. Inhalation toxicity of indoor air pollutants in Drosophila melanogaster using integrated transcriptomics and computational behavior analyses

    Science.gov (United States)

    Eom, Hyun-Jeong; Liu, Yuedan; Kwak, Gyu-Suk; Heo, Muyoung; Song, Kyung Seuk; Chung, Yun Doo; Chon, Tae-Soo; Choi, Jinhee

    2017-06-01

    We conducted an inhalation toxicity test on the alternative animal model, Drosophila melanogaster, to investigate potential hazards of indoor air pollution. The inhalation toxicity of toluene and formaldehyde was investigated using comprehensive transcriptomics and computational behavior analyses. The ingenuity pathway analysis (IPA) based on microarray data suggests the involvement of pathways related to immune response, stress response, and metabolism in formaldehyde and toluene exposure based on hub molecules. We conducted a toxicity test using mutants of the representative genes in these pathways to explore the toxicological consequences of alterations of these pathways. Furthermore, extensive computational behavior analysis showed that exposure to either toluene or formaldehyde reduced most of the behavioral parameters of both wild-type and mutants. Interestingly, behavioral alteration caused by toluene or formaldehyde exposure was most severe in the p38b mutant, suggesting that the defects in the p38 pathway underlie behavioral alteration. Overall, the results indicate that exposure to toluene and formaldehyde via inhalation causes severe toxicity in Drosophila, by inducing significant alterations in gene expression and behavior, suggesting that Drosophila can be used as a potential alternative model in inhalation toxicity screening.

  18. [Toxicity of polychlorinated biphenyls (PCB)--indoor air pollution by PCB-containing durable elastic sealants].

    Science.gov (United States)

    Ludewig, S; Kruse, H; Wassermann, O

    1993-01-01

    The widespread use of the persistent and lipophilic polychlorinated biphenyls (PCB) e.g. in electrical engineering, hydraulics and chemistry of the polymers, caused their ubiquitous distribution and accumulation in food chains. Chronic toxicity in humans is known from several incidents of PCB contaminated food. Dose-response experiences, however, remain uncertain due to the technical grade of PCB as a complex mixture of about 150 congeners and many impurities, like polychlorinated dibenzodurans. Some information on the toxicity of a few PCB congeners is available from animal experiments. Large differences in enzyme-inductive efficacy between the PCB congeners rendered the use of toxicity equivalent factors (related to 2,3,7,8-TCDD, "Seveso-Dioxin") necessary. For risk assessment, the use of "sum of PCB", calculated from questionable determinations of 6 minor toxic congeners, is insufficient. Serious problems arise from evaporation of PCB e.g. in technical rooms of telephone companies (in Germany: Telekom) and generally, from sealing materials in buildings. The German Federal Health Administration, BGA, recommends 300 ng total PCB/m3 indoor air as "precautionary value". Since neither the extreme differences in toxicity of the congeners nor bioaccumulation are taken into account, this recommendation of BGA can not be justified any longer.

  19. Pilot study investigating ambient air toxics emissions near a Canadian kraft pulp and paper facility in Pictou County, Nova Scotia.

    Science.gov (United States)

    Hoffman, Emma; Guernsey, Judith R; Walker, Tony R; Kim, Jong Sung; Sherren, Kate; Andreou, Pantelis

    2017-09-01

    Air toxics are airborne pollutants known or suspected to cause cancer or other serious health effects, including certain volatile organic compounds (VOCs), prioritized by the US Environmental Protection Agency (EPA). While several EPA-designated air toxics are monitored at a subset of Canadian National Air Pollution Surveillance (NAPS) sites, Canada has no specific "air toxics" control priorities. Although pulp and paper (P&P) mills are major industrial emitters of air pollutants, few studies quantified the spectrum of air quality exposures. Moreover, most NAPS monitoring sites are in urban centers; in contrast, rural NAPS sites are sparse with few exposure risk records. The objective of this pilot study was to investigate prioritized air toxic ambient VOC concentrations using NAPS hourly emissions data from a rural Pictou, Nova Scotia Kraft P&P town to document concentration levels, and to determine whether these concentrations correlated with wind direction at the NAPS site (located southwest of the mill). Publicly accessible Environment and Climate Change Canada data (VOC concentrations [Granton NAPS ID: 31201] and local meteorological conditions [Caribou Point]) were examined using temporal (2006-2013) and spatial analytic methods. Results revealed several VOCs (1,3-butadiene, benzene, and carbon tetrachloride) routinely exceeded EPA air toxics-associated cancer risk thresholds. 1,3-Butadiene and tetrachloroethylene were significantly higher (p towns and contribute to poor health in nearby communities.

  20. Effects of ground surface decontamination on the air radiation dose rate. Results of a decontamination trial at a playground lot in a Fukushima residential area

    International Nuclear Information System (INIS)

    Tagawa, Akihiro

    2012-01-01

    The Japan Atomic Energy Agency decontaminated schools, playgrounds, swimming pools, and houses in nonevacuated, less-contaminated areas in Fukushima for environmental restoration. A small, 150 m 2 playground lot in the residential area was chosen for decontamination demonstration, which used routinely available tools and commodities to carry out the work. The surfaces of playground lot equipment, such as swings, slides, and horizontal iron bars, were completely decontaminated by brushing with water and/or detergent. Side gutters around the playground lot were cleaned by removing the mud and then brushed and washed with a high-pressure water jet (7 MPa). The air dose rate at the playground lot was dominated by radiation from the ground surface and adjacent surroundings, such as apartments and rice fields. Two or three centimeters of the surface soil contaminated with cesium was removed manually with shovels, hoes, and other gardening tools. This significantly reduced the average air dose rate of the entire playground lot from 1.5 μSv/h before decontamination to 0.6 μSv/h. These results showed that ground surface decontamination can contribute measurably to the reduction in air dose rate in relatively small areas in residential areas. (author)

  1. Modeling the effects of reformulated gasoline usages on ambient concentrations of ozone and five air toxics

    International Nuclear Information System (INIS)

    Ligocki, M.P.; Schulhof, R.R.; Jackson, R.E.; Jimenez, M.M.; Atkinson, D.

    1993-01-01

    The use of reformulated gasolines to reduce motor-vehicle-related hydrocarbon emissions has been mandated by the 1990 Clean Air Act Amendments for nine severely polluted urban areas. Using a version of the Urban Airshed Model that includes explicit representation of five motor-vehicle-related air toxics, the effects of reformulated gasoline usage on ambient ozone and toxics concentrations were simulated. Simulations were conducted for two urban areas. Baltimore-Washington and Houston, for the year 1995. Additional simulation were conducted for Baltimore-Washington including winter and 1999 scenarios. In the Baltimore-Washington areas, the 1995 Federal reformulated gasoline scenario produce reductions of 1.1 percent in simulated peak ozone and 2.7 percent in the areal extent of simulated ozone exceedances. Simulated ozone reductions were much smaller in Houston. In the reformulated gasoline simulations, secondary formulation of formaldehyde and acetaldehyde was reduced, and decreases in ambient benzene and polycyclic organic matter (POM) concentrations were simulated. Larger reductions in ozone and toxics concentrations were simulated for reformulated gasolines meeting California Phase II standards than for those meeting Federal standards. The effects of reductions in motor-vehicle-related nitrogen oxides (NO x ) emissions, alone and in combination with hydrocarbon reductions, were also examined

  2. Notification: Background Investigation Services New Assignment Notification: EPA’s Efforts to Incorporate Environmental Justice Into Clean Air Act Inspections for Air Toxics

    Science.gov (United States)

    The purpose of this memorandum is to notify you that the EPA OIG plans to begin the preliminary research phase of an evaluation of the U.S. EPA's efforts to incorporate environmental justice into Clean Air Act inspections for air toxics.

  3. Effect of air pollution on respiratory tract diseases in small children. Morbidity rate in residential areas with varying degrees of severe pollution

    Energy Technology Data Exchange (ETDEWEB)

    Muehling, P.; Bory, J.; Haupt, H.

    1984-09-13

    In a retrospective study of hospitalized patients (children aged between 0 and 4 years) covering four years the dependence of the incidence of croup (infectious laryngitis) and obstructive bronchitis on air pollution was investigated. For this reason the incidence of morbidity in residential areas with various levels of SO/sub 2/ and sedimenting dust were compared. The results show a definitive connection between a high level of SO/sub 2/ and dust, respectively and a high rate of morbidity. This connection was particularly marked in areas with simultaneous high levels of both SO/sub 2/ and dust. The effects of confounding factors, such as infection incidence, meteorological influences, distances from hospital, social status, especially the percentage of foreign guest worker families and population density were investigated and separated from air pollution effects.

  4. Up the stack : coal-fired electricity's toxic impact : an OCAA air quality report

    International Nuclear Information System (INIS)

    Rang, S.

    2002-07-01

    Ontario Power Generation (OPG) must report annually its releases and transfers of 268 chemicals to the federal National Pollutant Release Inventory (NPRI). Each OPG facility reports the amount of chemicals released to the air, land, water and injected under ground at the facility site. The facilities must also report the amount of chemicals that are transferred off-site for treatment, sewage, disposal, recycling or energy recovery. In 1999 and 2000, atmospheric releases from OPG's coal-fired plants accounted for a significant percentage of the total pollutants released for Ontario and Canada. OPG's facilities are often in the top 5 in Ontario and Canada for releases of various chemicals, including persistent toxic chemicals. In 1999, the Nanticoke coal-fired power plant on Lake Erie was ranked first in Canada for releases to the air. Data reported for the 1999 and 2000 reporting period for dioxins and furans, hexachlorobenzene, mercury, metals (chromium, nickel and arsenic), and acid gases such as hydrochloric acid, hydrogen fluoride, and sulphuric acid clearly indicates that OPG coal-fired plants are a leading source of air pollution in Canada and Ontario. The Ontario Clean Air Alliance suggests the data is sufficient to phase-out the use of coal for power generation in Ontario. It recommends conserving energy and replacing coal-fired power with renewable energy sources such as wind and water power. Converting coal facilities to high-efficiency natural gas units would also reduce the toxic impacts of OPG's coal-fired power plants. As an immediate first step, it was recommended that the government should ban non-emergency exports of coal-fired electricity during smog-alert periods in Ontario. 11 tabs

  5. Projections of air toxic emissions from coal-fired utility combustion: Input for hazardous air pollutant regulators

    International Nuclear Information System (INIS)

    Szpunar, C.B.

    1993-01-01

    The US Environmental Protection Agency (EPA) is required by the 1990 CAAA to promulgate rules for all ''major'' sources of any of these HAPs. According to the HAPs section of the new Title III, any stationary source emitting 10 tons per year (TPY) of one HAP or 25 TPY of a combination of HAPs will be considered and designated a major source. In contrast to the original National Emission Standards for Hazardous Air Pollutants (NESHAP), which were designed to protect public health to ''an ample margin of safety,'' the new Title III, in its first phase, will regulate by industrial category those sources emitting HAPs in excess of the 10/25-TPY threshold levels, regardless of health risks. The trace elements normally associated with coal mineral matter and the various compounds formed during coal combustion have the potential to produce hazardous air toxic emissions from coal-fired electric utilities. Under Title III, the EPA is required to perform certain studies, prior to any regulation of electric utilities; these studies are currently underway. Also, the US Department of Energy (DOE) maintains a vested interest in addressing those energy policy questions affecting electric utility generation, coal mining, and steel producing critical to this country's economic well-being, where balancing the costs to the producers and users of energy with the benefits of environmental protection to the workers and the general populace remains of significant concern

  6. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  7. Residential Solar Systems.

    Science.gov (United States)

    Fulkerson, Dan

    This publication contains student and teacher instructional materials for a course in residential solar systems. The text is designed either as a basic solar course or as a supplement to extend student skills in areas such as architectural drafting, air conditioning and refrigeration, and plumbing. The materials are presented in four units…

  8. Reduced Toxicity, High Performance Monopropellant at the U.S. Air Force Research Laboratory

    Science.gov (United States)

    Hawkins, T. W.; Brand, A. J.; McKay, M. B.; Tinnirello, M.

    2010-09-01

    Current programs are aiming to develop reduced toxicity monopropellant formulations to replace spacecraft hydrazine monopropellant. The Air Force Research Laboratory's(AFRL's) approach to replacing hydrazine is the synthesis and development of energetic compounds/formulations with substantially less vapor toxicity and superior performance(specific impulse and density). Characterization and testing of these high energy density materials is an essential part of the screening process for viable advanced propellants. Hazardous handling characteristics, undesirable physical properties or unacceptable sensitivity behaviors must also be identified and/or modified to further development by a potential user. AFRL has successfully identified a novel monopropellant(designated AF-M315E) that shows great promise as an avenue toward replacement of hydrazine monopropellant for spacecraft propulsion. Hazard and safety/sensitivity, stability, and toxicity studies have been conducted on the monopropellant and will be described. The results from AF-M315E indicate that a >50% improvement in propulsion system performance over hydrazine is achievable while simultaneously providing a safer environment for the general public, ground personnel, crews and flight participants.

  9. Race, deprivation, and immigrant isolation: The spatial demography of air-toxic clusters in the continental United States.

    Science.gov (United States)

    Liévanos, Raoul S

    2015-11-01

    This article contributes to environmental inequality outcomes research on the spatial and demographic factors associated with cumulative air-toxic health risks at multiple geographic scales across the United States. It employs a rigorous spatial cluster analysis of census tract-level 2005 estimated lifetime cancer risk (LCR) of ambient air-toxic emissions from stationary (e.g., facility) and mobile (e.g., vehicular) sources to locate spatial clusters of air-toxic LCR risk in the continental United States. It then tests intersectional environmental inequality hypotheses on the predictors of tract presence in air-toxic LCR clusters with tract-level principal component factor measures of economic deprivation by race and immigrant status. Logistic regression analyses show that net of controls, isolated Latino immigrant-economic deprivation is the strongest positive demographic predictor of tract presence in air-toxic LCR clusters, followed by black-economic deprivation and isolated Asian/Pacific Islander immigrant-economic deprivation. Findings suggest scholarly and practical implications for future research, advocacy, and policy. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Air Toxics Emissions from Open Burning of Crop Residues in Southeast Asia

    Science.gov (United States)

    KIM Oanh, N. T.; Permadi, D. A.; Hopke, P. K.; Smith, K. R.; Nguyet, D. A.

    2016-12-01

    Agricultural crops production in Southeast Asia (SEA) increases annually to meet domestic consumption of growing population and also for export. Crop residue open burning (CROB) is commonly practiced by farmers to quickly dispose of huge amounts of the agricultural waste, such as rice straw, generated after each crop cycle. This CROB activity emits various toxic air pollutants as well as short-lived climate pollutants such as black carbon particles. Our study focused on quantifying the 2015 annual emissions of semi-volatile organic compounds including polycyclic aromatic hydrocarbons (PAHs), dioxins/furans (PCDD/PCDF), organochlorine pesticides (OCP), along with other conventional trace gases, particulate matter, and greenhouse gases from CROB in 10 major agricultural crop producing SEA countries. Crop production statistics and current field OB practices were gathered from our primary surveys and relevant secondary data sources. Emission factors for rice straw and maize residue burning were taken mainly from our measurements in Thailand while for other crops relevant published data were used. The best emission estimates of air toxics from CROB in SEA were 112 g-TEQ/yr of PCDD/PCDF, 33 t/yr of OCP, and 25 Gg/yr of total PAH of which the well-known carcinogenic benzo[a]pyrene was 0.3 Gg/yr. The CROB of rice production had the highest shares of emissions (33-95%) among considered 8 crop types. Indonesia was the top contributor to the total SEA emissions (30-45%) followed by Vietnam (16-26%), Thailand (6-22%) and Myanmar (5-18%). The spatial distributions of emissions, 0.1º x 0.1º, for each specie were prepared using MODIS land cover data. Temporally, higher emissions were observed in the harvesting months of the main rice crops. This emissions database can be used in regional air quality modeling studies to assess the impacts of CROB activity and to promote non-open burning alternatives.

  11. Air toxics and the risk of autism spectrum disorder: the results of a population based case-control study in southwestern Pennsylvania.

    Science.gov (United States)

    Talbott, Evelyn O; Marshall, Lynne P; Rager, Judith R; Arena, Vincent C; Sharma, Ravi K; Stacy, Shaina L

    2015-10-06

    Autism spectrum disorders (ASD) constitute a major public health problem affecting one in 68 children. There is little understanding of the causes of ASD despite its serious social impact. Air pollution contains many toxicants known to have adverse effects on the fetus. We conducted a population based case-control study in southwestern Pennsylvania to estimate the association between ASD and 2005 US EPA modeled NATA (National Air Toxics Assessment) levels for 30 neurotoxicants. A total of 217 ASD cases born between 2005 and 2009 were recruited from local ASD diagnostic and treatment centers. There were two different control groups: 1) interviewed controls (N = 224) frequency matched by child's year of birth, sex and race with complete residential histories from prior to pregnancy through the child's second birthday, and 2) 5,007 controls generated from a random sample of birth certificates (BC controls) using residence at birth. We used logistic regression analysis comparing higher to first quartile of exposure to estimate odds ratios (ORs) and 95% confidence intervals (CI), adjusting for mother's age, education, race, smoking status, child's year of birth and sex. Comparing fourth to first quartile exposures for all births, the adjusted OR for styrene was 2.04 (95% CI = 1.17-3.58, p = 0.013) for the interviewed case-control analysis and 1.61 (95% CI = 1.08-2.40, p = 0.018) for the BC analysis. In the BC comparison, chromium also exhibited an elevated OR of 1.60 (95% CI = 1.08-2.38, p = 0.020), which was similarly elevated in the interviewed analysis (OR = 1.52, 95% CI = 0.87-2.66). There were borderline significant ORs for the BC comparison for methylene chloride (OR = 1.41, 95% CI = 0.96-2.07, p = 0.082) and PAHs (OR = 1.44, 95% CI = 0.98-2.11, p = 0.064). Living in areas with higher levels of styrene and chromium during pregnancy was associated with increased risk of ASD, with borderline effects for PAHs and methylene chloride. These results are consistent with

  12. Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States.

    Science.gov (United States)

    Xiong, Youyou; Krogmann, Uta; Mainelis, Gediminas; Rodenburg, Lisa A; Andrews, Clinton J

    2015-01-01

    Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should

  13. Airborne persistent toxic substances (PTSs) in China: occurrence and its implication associated with air pollution.

    Science.gov (United States)

    Wang, Pu; Zhang, Qinghua; Li, Yingming; Matsiko, Julius; Zhang, Ya; Jiang, Guibin

    2017-08-16

    In recent years, China suffered from extensive air pollution due to the rapidly expanding economic and industrial developments. Its severe impact on human health has raised great concern currently. Persistent toxic substances (PTSs), a large group of environmental pollutants, have also received much attention due to their adverse effects on both the ecosystem and public health. However, limited studies have been conducted to reveal the airborne PTSs associated with air pollution at the national scale in China. In this review, we summarized the occurrence and variation of airborne PTSs in China, especially in megacities. These PTSs included polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), halogenated flame retardants (HFRs), perfluorinated compounds (PFCs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs) and heavy metals. The implication of their occurrence associated with air pollution was discussed, and the emission source of these chemicals was concluded. Most reviewed studies have been conducted in east and south China with more developed economy and industry. Severe contamination of airborne PTSs generally occurred in megacities with large populations, such as Guangzhou, Shanghai and Beijing. However, the summarized results suggested that industrial production and product consumption are the major sources of most PTSs in the urban environment, while unintentional emission during anthropogenic activities is an important contributor to airborne PTSs. It is important that fine particles serve as a major carrier of most airborne PTSs, which facilitates the long-range atmospheric transport (LRAT) of PTSs, and therefore, increases the exposure risk of the human body to these pollutants. This implied that not only the concentration and chemical composition of fine particles but also the absorbed PTSs are of particular concern when air pollution occurs.

  14. TOF-SIMS measurements for toxic air pollutants adsorbed on the surface of airborne particles

    Science.gov (United States)

    Tomiyasu, Bunbunoshin; Hoshi, Takahiro; Owari, Masanori; Nihei, Yoshimasa

    2003-01-01

    Three kinds of particulate matter were collected: diesel and gasoline exhaust particles emitted directly from exhaust nozzle, and suspended particulate matter (SPM) near the traffic route. Soxhlet extraction was performed on each sample. By gas-chromatograph-mass spectrometer (GC-MS) analysis of these extracts, di-ethyl phthalate and di- n-butyl phthalate were detected from the extract of SPM and diesel exhaust particles (DEPs). Because these phthalates were sometimes suspected as contamination, time-of-flight secondary ion mass spectrometry (TOF-SIMS) measurements were also performed on the samples collected at the same environment. By comparing obtained spectra, it is clear that these environmental endocrine disrupters (EEDs) were adsorbed on DEP surface. Thus, we concluded that the combination of conventional method and TOF-SIMS measurement is one of the most powerful techniques for analyzing the toxic air pollutants adsorbed on SPM surface.

  15. Silent Discharge Plasma Technology for the Treatment of Air Toxics and Other Applications

    Energy Technology Data Exchange (ETDEWEB)

    Rosocha, Louis A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chase, Peter J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gross, Michael P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    1998-09-21

    Under this CRADA, the Los Alamos National Laboratory (LANL) and High Mesa Technologies, Inc. (HMT) carried out a joint project on the development of the silent discharge plasma (SDP) technology for the treatment of hazardous air pollutants and other hazardous or toxic chemicals. The project had two major components: a technology-demonstration part and a scale-up and commercialization part. In the first part, a small-scale, mobile SDP plasma processor, which was being developed under a CRADA with the Electric Power Research Institute (EPRI) was the mobile equipment was modified for higher capacity service and employed for an innovative remediation technologies demonstration on soil-vapor extraction off-gases at the McClellan Air Force Base near Sacramento, CA. The performance of the SDP system for the variety of volatile organic compounds (VOCs) encountered at the McClellan site was sufficiently promising to the project HMT and LANL worked together to formulate a scale-up strategy and commercialization/manufacturing plan, and to design a prototype scaled-up SDP unit. HMT and LANL are now in the final stages of completing a licensing agreement for the technology and HMT is in the process of raising funds to engineer and manufacture commercial prototype SDP equipment focused on stack-gas emissions control and environmental remediation. HMT, in collaboration with another Northern New Mexico business, Coyote Aerospace, has also been successful in receiving a Phase I Small Business Innovative Research (SBIR) award from the Army Research Office to develop, design, and construct a small non-thermal plasma reactor for laboratory studies ("Non-Thermal Plasma Reactor for Control of Fugitive Emissions of Toxic Gases")

  16. Air pollution, land price development and assessment of immission control needs in urban development plans. The impact of immission pollution by sulphur dioxide and dust precipitation on property prices in residential areas of Dortmund and Duisburg

    International Nuclear Information System (INIS)

    Lee Chenjai.

    1993-01-01

    Air pollution, land price development and assessment of immission control needs in urban development plans. The impact of immission pollution by sulphur dioxide and dust precipitation on property prices in residential areas of Dortmund and Duisburg. The focus of this thesis is on studying the links between property prices and air pollution. The ground rent theory which goes back to the 16th century provides the theoretical basis for this work. RICARDO put forward the theory, that air may, under certain circumstances, - as for instance different local air pollution levels or sensitivity of locals to air quality -, which did not apply 200 years ago actually produce rent. These circumstances do indeed apply widely today - different air pollution levels in urban areas are just a case in point. Various empiricial studies in the U.S. proved that air pollution with different substances does actually influence the value of property. The ground rent influenced by air pollution is called ''air rent''. This study contains empirical studies on the influence of air pollution by sulphur dioxide SO 2 and dust precipitation on general property prices in residential areas of Dortmund between 1979 and 1989 and Duisburg between 1981 and 1989. (orig./UA) [de

  17. Performance Assessment of a Hybrid Solar-Geothermal Air Conditioning System for Residential Application: Energy, Exergy, and Sustainability Analysis

    Directory of Open Access Journals (Sweden)

    Yasser Abbasi

    2016-01-01

    Full Text Available This paper investigates the performance of a ground source heat pump that is coupled with a photovoltaic system to provide cooling and heating demands of a zero-energy residential building. Exergy and sustainability analyses have been conducted to evaluate the exergy destruction rate and SI of different compartments of the hybrid system. The effects of monthly thermal load variations on the performance of the hybrid system are investigated. The hybrid system consists of a vertical ground source heat exchanger, rooftop photovoltaic panels, and a heat pump cycle. Exergetic efficiency of the solar-geothermal heat pump system does not exceed 10 percent, and most exergy destruction takes place in photovoltaic panel, condenser, and evaporator. Although SI of PV system remains constant during a year, SI of GSHP varies depending on cooling and heating mode. The results also show that utilization of this hybrid system can reduce CO2 emissions by almost 70 tons per year.

  18. High Time Resolution Measurements of VOCs from Vehicle Cold Starts: The Air Toxic Cold Start Pulse

    Science.gov (United States)

    Jobson, B. T.; Huangfu, Y.; Vanderschelden, G. S.

    2017-12-01

    Pollutants emitted during motor vehicle cold starts, especially in winter in some climates, is a significant source of winter time air pollution. While data exist for CO, NO, and total hydrocarbon emissions from federal testing procedures for vehicle emission certification, little is known about the emission rates of individual volatile organic compounds, in particular the air toxics benzene, formaldehyde, and acetaldehyde. Little is known about the VOC speciation and temperature dependence for cold starts. The US EPA vehicle emission model MOVES assumes that cold start emissions have the same speciation profile as running emissions. We examined this assumption by measuring cold start exhaust composition for 4 vehicles fueled with E10 gasoline over a temperature range of -4°C to 10°C in winter of 2015. The extra cold start emissions were determined by comparison with emissions during engine idling. In addition to CO and NOx measurements a proton transfer reaction mass spectrometer was used to measure formaldehyde, acetaldehyde, benzene, toluene, and C2-alkylbenzenes at high time resolution to compare with the cold start emission speciation profiles used in the EPA MOVES2014 model. The results show that after the vehicle was started, CO mixing ratios can reach a few percent of the exhaust and then drop to several ppmv within 2 minutes of idling, while NOx showed different temporal behaviors among the four vehicles. VOCs displayed elevated levels during cold start and the peak mixing ratios can be two orders higher than idling phase levels. Molar emission ratios relative to toluene were used to compare with the emission ratio used in MOVES2014 and we found the formaldehyde-to-toluene emission ratio was about 0.19, which is 5 times higher than the emission ratio used in MOVES2014 and the acetaldehyde-to-toluene emission ratios were 0.86-0.89, which is 8 times higher than the ones in MOVES2014. The C2-alkylbenzene-to-toluene ratio agreed well with moves. Our results

  19. Assessment of windows on noise intrusion, energy efficiency, and indoor air quality for residential buildings near airports.

    Science.gov (United States)

    2012-06-01

    The continuing increase in air traffic has implications for the preservation of our common : resources and causes global and micro-environmental pollution. This pollution affects public : health and causes damage to the prospects of future generation...

  20. Volatile organic compound conversion by ozone, hydroxyl radicals, and nitrate radicals in residential indoor air: Magnitudes and impacts of oxidant sources

    Science.gov (United States)

    Waring, Michael S.; Wells, J. Raymond

    2015-04-01

    Indoor chemistry may be initiated by reactions of ozone (O3), the hydroxyl radical (OH), or the nitrate radical (NO3) with volatile organic compounds (VOC). The principal indoor source of O3 is air exchange, while OH and NO3 formation are considered as primarily from O3 reactions with alkenes and nitrogen dioxide (NO2), respectively. Herein, we used time-averaged models for residences to predict O3, OH, and NO3 concentrations and their impacts on conversion of typical residential VOC profiles, within a Monte Carlo framework that varied inputs probabilistically. We accounted for established oxidant sources, as well as explored the importance of two newly realized indoor sources: (i) the photolysis of nitrous acid (HONO) indoors to generate OH and (ii) the reaction of stabilized Criegee intermediates (SCI) with NO2 to generate NO3. We found total VOC conversion to be dominated by reactions both with O3, which almost solely reacted with D-limonene, and also with OH, which reacted with D-limonene, other terpenes, alcohols, aldehydes, and aromatics. VOC oxidation rates increased with air exchange, outdoor O3, NO2 and D-limonene sources, and indoor photolysis rates; and they decreased with O3 deposition and nitric oxide (NO) sources. Photolysis was a strong OH formation mechanism for high NO, NO2, and HONO settings, but SCI/NO2 reactions weakly generated NO3 except for only a few cases.

  1. Air toxics exposure from vehicle emissions at a U.S. border crossing: Buffalo Peace Bridge Study.

    Science.gov (United States)

    Spengler, John; Lwebuga-Mukasa, Jamson; Vallarino, Jose; Melly, Steve; Chillrud, Steve; Baker, Joel; Minegishi, Taeko

    2011-07-01

    The Peace Bridge in Buffalo, New York, which spans the Niagara River at the east end of Lake Erie, is one of the busiest U.S. border crossings. The Peace Bridge plaza on the U.S. side is a complex of roads, customs inspection areas, passport control areas, and duty-free shops. On average 5000 heavy-duty diesel trucks and 20,000 passenger cars traverse the border daily, making the plaza area a potential "hot spot" for emissions from mobile sources. In a series of winter and summer field campaigns, we measured air pollutants, including many compounds considered by the U.S. Environmental Protection Agency (EPA*) as mobile-source air toxics (MSATs), at three fixed sampling sites: on the shore of Lake Erie, approximately 500 m upwind (under predominant wind conditions) of the Peace Bridge plaza; immediately downwind of (adjacent to) the plaza; and 500 m farther downwind, into the community of west Buffalo. Pollutants sampled were particulate matter (PM) Peace Bridge plaza using portable instruments and Global Positioning System (GPS) tracking. The study was designed to assess differences in upwind and downwind concentrations of MSATs, in areas near the Peace Bridge plaza on the U.S. side of the border. The Buffalo Peace Bridge Study featured good access to monitoring locations proximate to the plaza and in the community, which are downwind with the dominant winds from the direction of Lake Erie and southern Ontario. Samples from the lakeside Great Lakes Center (GLC), which is upwind of the plaza with dominant winds, were used to characterize contaminants in regional air masses. On-site meteorologic measurements and hourly truck and car counts were used to assess the role of traffic on UFP counts and pPAH concentrations. The array of parallel and perpendicular residential streets adjacent to the plaza provided a grid on which to plot the spatial patterns of UFP counts and pPAH concentrations to determine the extent to which traffic emissions from the Peace Bridge plaza

  2. A comparison of four methods to evaluate the effect of a utility residential air-conditioner load control program on peak electricity use

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R., E-mail: guy.newsham@nrc-cnrc.gc.ca [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Birt, Benjamin J. [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Rowlands, Ian H. [University of Waterloo, Ontario (Canada)

    2011-10-15

    We analyzed the peak load reductions due to a residential direct load control program for air-conditioners in southern Ontario in 2008. In this program, participant thermostats were increased by 2 deg. C for four hours on five event days. We used hourly, whole-house data for 195 participant households and 268 non-participant households, and four different methods of analysis ranging from simple spreadsheet-based comparisons of average loads on event days, to complex time-series regression. Average peak load reductions were 0.2-0.9 kWh/h per household, or 10-35%. However, there were large differences between event days and across event hours, and in results for the same event day/hour, with different analysis methods. There was also a wide range of load reductions between individual households, and only a minority of households contributed to any given event. Policy makers should be aware of how the choice of an analysis method may affect decisions regarding which demand-side management programs to support, and how they might be incentivized. We recommend greater use of time-series methods, although it might take time to become comfortable with their complexity. Further investigation of what type of households contribute most to aggregate load reductions would also help policy makers better target programs. - Highlights: > We analyzed peak load reductions due to residential a/c load control. > We used four methods, ranging from simple comparisons to time-series regression. > Average peak load reductions were 0.2-0.9 kW per household, varying by method. > We recommend a move towards time-series regression for future studies. > A minority of participant households contributed to a given load control event.

  3. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source...

  4. Mercury and Air Toxic Element Impacts of Coal Combustion By-Product Disposal and Utilizaton

    Energy Technology Data Exchange (ETDEWEB)

    David Hassett; Loreal Heebink; Debra Pflughoeft-Hassett; Tera Buckley; Erick Zacher; Mei Xin; Mae Sexauer Gustin; Rob Jung

    2007-03-31

    The University of North Dakota Energy & Environmental Research Center (EERC) conducted a multiyear study to evaluate the impact of mercury and other air toxic elements (ATEs) on the management of coal combustion by-products (CCBs). The ATEs evaluated in this project were arsenic, cadmium, chromium, lead, nickel, and selenium. The study included laboratory tasks to develop measurement techniques for mercury and ATE releases, sample characterization, and release experiments. A field task was also performed to measure mercury releases at a field site. Samples of fly ash and flue gas desulfurization (FGD) materials were collected preferentially from full-scale coal-fired power plants operating both without and with mercury control technologies in place. In some cases, samples from pilot- and bench-scale emission control tests were included in the laboratory studies. Several sets of 'paired' baseline and test fly ash and FGD materials collected during full-scale mercury emission control tests were also included in laboratory evaluations. Samples from mercury emission control tests all contained activated carbon (AC) and some also incorporated a sorbent-enhancing agent (EA). Laboratory release experiments focused on measuring releases of mercury under conditions designed to simulate CCB exposure to water, ambient-temperature air, elevated temperatures, and microbes in both wet and dry conditions. Results of laboratory evaluations indicated that: (1) Mercury and sometimes selenium are collected with AC used for mercury emission control and, therefore, present at higher concentrations than samples collected without mercury emission controls present. (2) Mercury is stable on CCBs collected from systems both without and with mercury emission controls present under most conditions tested, with the exception of vapor-phase releases of mercury exposed to elevated temperatures. (3) The presence of carbon either from added AC or from unburned coal can result in mercury

  5. Evaluation of Technical and Utility Programmatic Challenges With Residential Forced-Air Integrated Space/Water Heat Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kingston, Tim [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Vadnal, Hillary [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Scott, Shawn [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Kalensky, Dave [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States)

    2016-12-01

    This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented ETPs.

  6. Land use regression modeling of intra-urban residential variability in multiple traffic-related air pollutants

    OpenAIRE

    Clougherty, Jane E; Wright, Rosalind J; Baxter, Lisa K; Levy, Jonathan I

    2008-01-01

    Abstract Background There is a growing body of literature linking GIS-based measures of traffic density to asthma and other respiratory outcomes. However, no consensus exists on which traffic indicators best capture variability in different pollutants or within different settings. As part of a study on childhood asthma etiology, we examined variability in outdoor concentrations of multiple traffic-related air pollutants within urban communities, using a range of GIS-based predictors and land ...

  7. Sediment contamination of residential streams in the metropolitan kansas city area, USA: Part II. whole-sediment toxicity to the amphipod hyalella azteca

    Science.gov (United States)

    Tao, J.; Ingersoll, C.G.; Kemble, N.E.; Dias, J.R.; Murowchick, J.B.; Welker, G.; Huggins, D.

    2010-01-01

    This is the second part of a study that evaluates the influence of nonpoint sources on the sediment quality of five adjacent streams within the metropolitan Kansas City area, central United States. Physical, chemical, and toxicity data (Hyalella azteca 28-day whole-sediment toxicity test) for 29 samples collected in 2003 were used for this evaluation, and the potential causes for the toxic effects were explored. The sediments exhibited a low to moderate toxicity, with five samples identified as toxic to H. azteca. Metals did not likely cause the toxicity based on low concentrations of metals in the pore water and elevated concentrations of acid volatile sulfide in the sediments. Although individual polycyclic aromatic hydrocarbons (PAHs) frequently exceeded effect-based sediment quality guidelines [probable effect concentrations (PECs)], only four of the samples had a PEC quotient (PEC-Q) for total PAHs over 1.0 and only one of these four samples was identified as toxic. For the mean PEC-Q for organochlorine compounds (chlordane, dieldrin, sum DDEs), 4 of the 12 samples with a mean PEC-Q above 1.0 were toxic and 4 of the 8 samples with a mean PEC-Q above 3.0 were toxic. Additionally, four of eight samples were toxic, with a mean PEC-Q above 1.0 based on metals, PAHs, polychlorinated biphenyls (PCBs), and organochlorine pesticides. The increase in the incidence of toxicity with the increase in the mean PEC-Q based on organochlorine pesticides or based on metals, PAHs, PCBs, and organochlorine pesticides suggests that organochlorine pesticides might have contributed to the observed toxicity and that the use of a mean PEC-Q, rather than PEC-Qs for individual compounds, might be more informative in predicting toxic effects. Our study shows that stream sediments subject to predominant nonpoint sources contamination can be toxic and that many factors, including analysis of a full suite of PAHs and pesticides of both past and present urban applications and the origins of

  8. System approach for evaluation of air pollution toxic compounds in the 30-km area of nuclear power plants

    International Nuclear Information System (INIS)

    Shevtsova, O.V.; Zhigunova, L.N.; Makovskaya, N.A.; Pavlovich, E.L.

    2012-01-01

    The article shows the importance of a systematic approach to address environmental problems that arise during the construction of nuclear power plants, and identified the need to consider the transformation and biotransformation of primary pollutants and monitoring secondary pollutants. The basic pathways of pollutants in the air a 30-km zone of nuclear power plants established. The content of primary and secondary air pollutants identified. The evaluation of general toxic risk from primary pollutant and the calculation of the carcinogenic risk of secondary pollutants entering the body by inhalation are carried out. (authors)

  9. Comparison between predicted duct effectiveness from proposed ASHRAE Standard 152P and measured field data for residential forced air cooling systems; TOPICAL

    International Nuclear Information System (INIS)

    Siegel, Jeffrey A.; McWilliams, Jennifer A.; Walker, Iain S.

    2002-01-01

    The proposed ASHRAE Standard 152P ''Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems'' (ASHRAE 2002) has recently completed its second public review. As part of the standard development process, this study compares the forced air distribution system ratings provided by the public review draft of Standard 152P to measured field results. 58 field tests were performed on cooling systems in 11 homes in the summers of 1998 and 1999. Seven of these houses had standard attics with insulation on the attic floor and a well-vented attic space. The other four houses had unvented attics where the insulation is placed directly under the roof deck and the attic space is not deliberately vented. Each house was tested under a range of summer weather conditions at each particular site, and in some cases the amount of duct leakage was intentionally varied. The comparison between 152P predicted efficiencies and the measured results includes evaluation of the effects of weather, duct location, thermal conditions, duct leakage, and system capacity. The results showed that the difference between measured delivery effectiveness and that calculated using proposed Standard 152P is about 5 percentage points if weather data, duct leakage and air handler flow are well known. However, the accuracy of the standard is strongly dependent on having good measurements of duct leakage and system airflow. Given that the uncertainty in the measured delivery effectiveness is typically also about 5 percentage points, the Standard 152P results are acceptably close to the measured data

  10. Air pollution: what matters most? : Physical, chemical and oxidative properties of air pollution components related to toxic effects

    NARCIS (Netherlands)

    Steenhof, M.|info:eu-repo/dai/nl/304822426

    2015-01-01

    Numerous studies have been published on the adverse health effects associated with both short- and long-term exposure to air pollution. Air pollution is a heterogeneous, complex mixture of gases, liquids, and particulate matter (PM). Up to now, PM mass concentration has been the metric of choice to

  11. Thermal Stress and Toxicity

    Science.gov (United States)

    Elevating ambient temperature above thermoneutrality exacerbates toxicity of most air pollutants, insecticides, and other toxic chemicals. On the other hand, safety and toxicity testing of toxicants and drugs is usually performed in mice and rats maintained at subthermoneutral te...

  12. Comparison of a Constant Air Volume (CAV) and a Demand Controlled Ventilation (DCV) System in a Residential Building

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    The aim of this paper was to compare the indoor climate and the energy performance of a Constant Air Volume (CAV) system of 0.5h-1 with a Demand Controlled Ventilation (DCV) system controlled by occupancy and relative humidity for a studio apartment. Furthermore the impact of building materials...... it was found that the energy consumption for heating and operating the ventilation system could be reduced by respectively 8.0% and 10.6 % in the case of DCV without negative impact on the indoor climate. Including the hygroscopic properties of the materials resulted in a reduction of the energy consumption...... for heating and operating the ventilation system by respectively 9.5% and 17.1 % in favour of the DCV system....

  13. Place of work and residential exposure to ambient air pollution and birth outcomes in Scotland, using geographically fine pollution climate mapping estimates.

    Science.gov (United States)

    Dibben, Chris; Clemens, Tom

    2015-07-01

    A relationship between ambient air pollution and adverse birth outcomes has been found in a large number of studies that have mainly used a nearest monitor methodology. Recent research has suggested that the effect size may have been underestimated in these studies. This paper examines associations between birth outcomes and ambient levels of residential and workplace sulphur dioxide, particulates and Nitrogen Dioxide estimated using an alternative method - pollution climate mapping. Risk of low birthweight and mean birthweight (for n=21,843 term births) and risk of preterm birth (for n=23,086 births) were modelled against small area annual mean ambient air pollution concentrations at work and residence location adjusting for potential confounding factors for singleton live births (1994-2008) across Scotland. Odds ratios of low birthweight of 1.02 (95% CI, 1.01-1.03) and 1.07 (95% CI, 1.01-1.12) with concentration increases of 1 µg/m(3) for NO2 and PM10 respectively. Raised but insignificant risks of very preterm birth were found with PM10 (relative risk ratio=1.08; 95% CI, 1.00 to 1.17 per 1 µg/m(3)) and NO2 (relative risk ratio=1.01; 95% CI, 1.00 to 1.03 per 1 µg/m(3)). An inverse association between mean birthweight and mean annual NO2(-1.24 g; 95% CI, -2.02 to -0.46 per 1 µg/m(3)) and PM10 (-5.67 g; 95% CI, -9.47 to -1.87 per 1 µg/m(3)). SO2 showed no significant associations. This study highlights the association between air pollution exposure and reduced newborn size at birth. Together with other recent work it also suggests that exposure estimation based on the nearest monitor method may have led to an under-estimation of the effect size of pollutants on birth outcomes. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Identifying inequitable exposure to toxic air pollution in racialized and low-income neighbourhoods to support pollution prevention

    Directory of Open Access Journals (Sweden)

    Suzanne Kershaw

    2013-05-01

    Full Text Available Numerous environmental justice studies have confirmed a relationship between population characteristics such as low-income or minority status and the location of environmental health hazards. However, studies of the health risks from exposure to harmful substances often do not consider their toxicological characteristics. We used two different methods, the unit-hazard and the distance-based approach, to evaluate demographic and socio-economic characteristics of the population residing near industrial facilities in the City of Toronto, Canada. In addition to the mass of air emissions obtained from the national pollutant release inventory (NPRI, we also considered their toxicity using toxic equivalency potential (TEP scores. Results from the unit-hazard approach indicate no significant difference in the proportion of low-income individuals living in host versus non-host census tracts (t(107 = 0.3, P = 0.735. However, using the distance-based approach, the proportion of low-income individuals was significantly higher (+5.1%, t(522 = 6.0, P <0.001 in host tracts, while the indicator for “racialized” communities (“visible minority” was 16.1% greater (t(521 = 7.2, P <0.001 within 2 km of a NPRI facility. When the most toxic facilities by non-carcinogenic TEP score were selected, the rate of visible minorities living near the most toxic NPRI facilities was significantly higher (+12.9%, t(352 = 3.5, P = 0.001 than near all other NPRI facilities. TEP scores were also used to identify areas in Toronto that face a double burden of poverty and air toxics exposure in order to prioritise pollution prevention.

  15. Ultra High Efficiency ESP for Fine Particulate and Air Toxics Control

    International Nuclear Information System (INIS)

    Srinivasachar, Srivats; Pease, Benjamin R.; Porle, Kjell; Mauritzson, Christer; Haythornthwaite, Sheila

    1997-01-01

    Nearly ninety percent of U.S. coal-fired utility boilers are equipped with electrostatic precipitators (ESP). Cost effective retrofittable ESP technologies are the only means to accomplish Department of Energy's (DOE) goal of a major reduction in fine particulate and air toxic emissions from coal-fired power plants. Particles in the size range of 0.1 to 5 (micro)m typically escape ESPs. Metals, such as arsenic, cadmium, lead, molybdenum and antimony, concentrate on these particles. This is the main driver for improved fine particulate control. Vapor phase emissions of mercury, selenium and arsenic are also of major concern. Current dry ESPs, which operate at temperatures greater than 280 F, provide little control for vapor phase toxics. The need for inherent improvement to ESPs has to be considered keeping in perspective the current trend towards the use of low sulfur coals. Switching to low sulfur coals is the dominant approach for SO 2 emission reduction in the utility industry. Low sulfur coals generate high resistivity ash, which can cause an undesirable phenomenon called ''back corona.'' Higher particulate emissions occur if there is back corona in the ESP. Results of the pilot-scale testing identified the ''low temperature ESP'' concept to have the biggest impact for the two low sulfur coals investigated. Lowering the flue gas temperature to 220 F provided the maximum impact in terms of decreased emissions. Intermediate operating temperatures (reduction from 340 to 270 F) also gave significant ESP performance improvement. A significant reduction in particulate emissions was also noted when the flue gas humidity was increased (temperature held constant) from the baseline condition for these moderately high resistivity ash coals. Independent control of flue gas humidity and temperature was an important and a notable element in this project. Mercury emissions were also measured as a function of flue gas temperature. Mercury emissions decreased as the flue gas

  16. Ultra High Efficiency ESP for Fine Particulate and Air Toxics Control

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasachar, Srivats; Pease, Benjamin R.; Porle, Kjell; Mauritzson, Christer; Haythornthwaite, Sheila

    1997-07-01

    Nearly ninety percent of U.S. coal-fired utility boilers are equipped with electrostatic precipitators (ESP). Cost effective retrofittable ESP technologies are the only means to accomplish Department of Energy's (DOE) goal of a major reduction in fine particulate and air toxic emissions from coal-fired power plants. Particles in the size range of 0.1 to 5 {micro}m typically escape ESPs. Metals, such as arsenic, cadmium, lead, molybdenum and antimony, concentrate on these particles. This is the main driver for improved fine particulate control. Vapor phase emissions of mercury, selenium and arsenic are also of major concern. Current dry ESPs, which operate at temperatures greater than 280 F, provide little control for vapor phase toxics. The need for inherent improvement to ESPs has to be considered keeping in perspective the current trend towards the use of low sulfur coals. Switching to low sulfur coals is the dominant approach for SO{sub 2} emission reduction in the utility industry. Low sulfur coals generate high resistivity ash, which can cause an undesirable phenomenon called ''back corona.'' Higher particulate emissions occur if there is back corona in the ESP. Results of the pilot-scale testing identified the ''low temperature ESP'' concept to have the biggest impact for the two low sulfur coals investigated. Lowering the flue gas temperature to 220 F provided the maximum impact in terms of decreased emissions. Intermediate operating temperatures (reduction from 340 to 270 F) also gave significant ESP performance improvement. A significant reduction in particulate emissions was also noted when the flue gas humidity was increased (temperature held constant) from the baseline condition for these moderately high resistivity ash coals. Independent control of flue gas humidity and temperature was an important and a notable element in this project. Mercury emissions were also measured as a function of flue gas

  17. Land use regression modeling of intra-urban residential variability in multiple traffic-related air pollutants

    Directory of Open Access Journals (Sweden)

    Baxter Lisa K

    2008-05-01

    Full Text Available Abstract Background There is a growing body of literature linking GIS-based measures of traffic density to asthma and other respiratory outcomes. However, no consensus exists on which traffic indicators best capture variability in different pollutants or within different settings. As part of a study on childhood asthma etiology, we examined variability in outdoor concentrations of multiple traffic-related air pollutants within urban communities, using a range of GIS-based predictors and land use regression techniques. Methods We measured fine particulate matter (PM2.5, nitrogen dioxide (NO2, and elemental carbon (EC outside 44 homes representing a range of traffic densities and neighborhoods across Boston, Massachusetts and nearby communities. Multiple three to four-day average samples were collected at each home during winters and summers from 2003 to 2005. Traffic indicators were derived using Massachusetts Highway Department data and direct traffic counts. Multivariate regression analyses were performed separately for each pollutant, using traffic indicators, land use, meteorology, site characteristics, and central site concentrations. Results PM2.5 was strongly associated with the central site monitor (R2 = 0.68. Additional variability was explained by total roadway length within 100 m of the home, smoking or grilling near the monitor, and block-group population density (R2 = 0.76. EC showed greater spatial variability, especially during winter months, and was predicted by roadway length within 200 m of the home. The influence of traffic was greater under low wind speed conditions, and concentrations were lower during summer (R2 = 0.52. NO2 showed significant spatial variability, predicted by population density and roadway length within 50 m of the home, modified by site characteristics (obstruction, and with higher concentrations during summer (R2 = 0.56. Conclusion Each pollutant examined displayed somewhat different spatial patterns

  18. Smart Control System to Optimize Time of Use in a Solar-Assisted Air-Conditioning by Ejector for Residential Sector

    Directory of Open Access Journals (Sweden)

    Giovanna Avedian-González

    2018-02-01

    Full Text Available The present work provides a series of theoretical improvements of a control strategy in order to optimize the time of use of solar air-conditioning by an ejector distributed in multiple solar collectors of vacuum tubes for the residential sector, which will allow us to reduce carbon-dioxide emissions, costs and electrical energy consumption. In a solar ejector cooling system, the instability of the solar source of energy causes an operational conflict between the solar thermal system and ejector cooling cycle. A fuzzy control structure for the supervisory ejector cycle and multi-collector control system is developed: the first control is applied to control the mass flow of the generator and the evaporator for different cooling capacities (3, 3.5, 4, 4.5 and 5 kW and set a temperature reference according to the operating conditions; the second is applied to keep a constant temperature power source that feeds the low-grade ejector cooling cycle using R134aas refrigerant. For the present work, the temperature of the generator oscillates between 65 °C and 90 °C, a condenser temperature of 30 °C and an evaporator temperature of 10 °C. For the purpose of optimization, there are different levels of performance for time of use: the Mode 0 (economic gives a performance of 17.55 h, Mode 5 (maximum cooling power 14.86 h and variable mode (variable mode of capacities 16.25 h, on average. Simulations are done in MATLAB-Simulink applying fuzzy logic for a mathematical model of the thermal balance. They are compared with two different types of solar radiation: real radiation and disturbed radiation.

  19. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  20. Monitoring of air toxics through air pathways in support of a No-Migration permit at a refinery land treatment facility

    International Nuclear Information System (INIS)

    Wineberry, W.T. Jr.; McReynolds, J.

    1991-01-01

    As part of Exxon's petition of the EPA for No-Migration variances, ambient concentrations of toxicants and carcinogens are required to be verified through onsite monitoring for comparison to the appropriate health based limits as well as for calibration of previously used atmospheric dispersion models. Ambient air around land treatment facilities us a very complex, dynamic system of interacting chemicals. Pollutants can be found in the gas phase, in the particulate phase, or in the aerosol phase. The complex nature of the dynamic air system around these facilities contributes to the complexity of the sampling and analytical selection for the identification and quantification for these chemicals. The selection of the proper sampling and analysis methods for a pollutant depends on many important interrelated factors, including compounds of interest, the level of detection required, the degree of specificity needed, and the purpose of the data collected. Other factors which may be as important as the above are cost, the accuracy and precision required, need for real-time versus long-term data, and the need for on-site or off-site analysis. Sampling time, sampling rate, the volume of air to be sampled and the acceptable risk level are also factors which must be considered when choosing a sampling method. The purpose of the ambient air monitoring program is to obtain a comparison of predicted concentration to those measured. This paper will focus on the ambient air monitoring program at Exxon's land treatment facility as part of a No-Migration variance to EPA's Land Ban Regulations. Ambient Air Monitoring data involving volatile, semi-volatile and metals/particulate matter less than ten microns (PM-10) will be presented

  1. Exposure information in environmental health research: Current opportunities and future directions for particulate matter, ozone, and toxic air pollutants

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Ryan, P. Barry; Ozkaynak, Haluk

    2007-02-01

    Understanding and quantifying outdoor and indoor sources of human exposure are essential but often not adequately addressed in health-effects studies for air pollution. Air pollution epidemiology, risk assessment, health tracking and accountability assessments are examples of health-effects studies that require but often lack adequate exposure information. Recent advances in exposure modeling along with better information on time-activity and exposure factors data provide us with unique opportunities to improve the assignment of exposures for both future and ongoing studies linking air pollution to health impacts. In September 2006, scientists from the US Environmental Protection Agency (EPA) and the Centers for Disease Control and Prevention (CDC) along with scientists from the academic community and state health departments convened a symposium on air pollution exposure and health in order to identify, evaluate, and improve current approaches for linking air pollution exposures to disease. This manuscript presents the key issues, challenges and recommendations identified by the exposure working group, who used cases studies of particulate matter, ozone, and toxic air pollutant exposure to evaluate health-effects for air pollution. One of the over-arching lessons of this workshop is that obtaining better exposure information for these different health-effects studies requires both goal-setting for what is needed and mapping out the transition pathway from current capabilities to meeting these goals. Meeting our long-term goals requires definition of incremental steps that provide useful information for the interim and move us toward our long-term goals. Another over-arching theme among the three different pollutants and the different health study approaches is the need for integration among alternate exposure assessment approaches. For example, different groups may advocate exposure indicators, biomonitoring, mapping methods (GIS), modeling, environmental media

  2. "Air Toxics under the Big Sky": Examining the Effectiveness of Authentic Scientific Research on High School Students' Science Skills and Interest

    Science.gov (United States)

    Ward, Tony J.; Delaloye, Naomi; Adams, Earle Raymond; Ware, Desirae; Vanek, Diana; Knuth, Randy; Hester, Carolyn Laurie; Marra, Nancy Noel; Holian, Andrij

    2016-01-01

    "Air Toxics Under the Big Sky" is an environmental science outreach/education program that incorporates the Next Generation Science Standards (NGSS) 8 Practices with the goal of promoting knowledge and understanding of authentic scientific research in high school classrooms through air quality research. This research explored: (1)…

  3. [Comparison of four multivariate calibration methods in simultaneous determination of air toxic organic compounds with FTIR spectroscopy].

    Science.gov (United States)

    Li, Yan; Wang, Jun-de; Chen, Zuo-ru; Zhou, Xue-tie; Huang, Zhong-hua

    2002-10-01

    The concentration determination abilities of four multivariate calibration methods--classical least squares (CLS), partial least squares (PLS), kalman filter method (KFM) and artificial neural network (ANN) were compared in this paper. Five air toxic organic compounds--1,3-butadiene, benzene, o-xylen, chlorobenzene, and acrolein--whose FTIR spectra seriously overlap each other were selected to compose the analytical objects. The evaluation criterion was according to the mean prediction error (MPE) and mean relative error (MRE). Results showed that PLS was superior to other methods when treating multicomponent analysis problem, while there was no comparable difference between CLS, KFM and ANN.

  4. Dietary and Pharmacological Intervention to Mitigate the Cardiopulmonary Effects of Air Pollution Toxicity

    Science.gov (United States)

    Background: Human exposure to air pollution has long been associated with excess morbidity and mortality. Although regulatory measures carried out under the “Clean Air Act” have saved millions of lives, there are still hundreds of thousands of people in the U.S. that live in area...

  5. Toxic deposition monitoring network data listing for organochlorine pesticides and polychlorinated biphenyls in air and precipitation 1989 and 1990

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    The Ontario environment ministry established a toxics deposition network in 1987 to monitor for polychlorinated biphenyls (PCBs), organochlorine pesticides (OCs), trace metals, polycyclic aromatic hydrocarbons, dioxins, and furans in air and precipitation. Monitoring sites are located along each Canadian shoreline of the Great Lakes. Data are presented from the 1989 and 1990 air and precipitation monitoring results for PCBs and OCs. The sampling and analytical methods, data screening methods, and codes used in the data tables are explained. Each data listing is identified by station name, and individual sample records are listed consecutively by sample collection date. Each sample record includes a heading consisting of several field sample collection information data fields and a number of analytical results. PCBs are listed by congener group (up to nonachlorobiphenyl) and as a congener group sum. The OCs measured include Heptachlor, Aldrin, Mirex, chlordane, hexachlorocyclohexanes, and dichloro diphenyl trichloroethane. 3 refs., 1 fig., 10 tabs.

  6. Future research needs associated with the assessment of potential human health risks from exposure to toxic ambient air pollutants

    DEFF Research Database (Denmark)

    Möller, Lennart; Schuetzle, Dennis; Autrup, Herman

    1994-01-01

    This paper presents key conclusions and future research needs from a Workshop on the Risk Assessment of Urban Air, Emissions, Exposure, Risk Identification, and Quantification, which was held in Stockholm during June 1992 by 41 participants from 13 countries. Research is recommended in the areas...... of identification and quantification of toxics in source emissions and ambient air, atmospheric transport and chemistry, exposure level assessment, the development of improved in vitro bioassays, biomarker development, the development of more accurate epidemiological methodologies, and risk quantification...... techniques. Studies are described that will be necessary to assess and reduce the level of uncertainties associated with each step of the risk assessment process. International collaborative research efforts between industry and government organizations are recommended as the most effective way to carry out...

  7. Air toxics and epigenetic effects: ozone altered microRNAs in the sputum of human subjects

    Science.gov (United States)

    Ozone (03) is a criteria air pollutant that is associated with numerous adverse health effects, including altered respiratory immune responses. Despite its deleterious health effects, possible epigenetic mechanisms underlying 03-induced health effects remain understudied. MicroRN...

  8. Criteria and air-toxic emissions from in-use automobiles in the National Low-Emission Vehicle program.

    Science.gov (United States)

    Baldauf, Rich W; Gabele, Pete; Crews, William; Snow, Richard; Cook, J Rich

    2005-09-01

    The U.S. Environmental Protection Agency (EPA) implemented a program to identify tailpipe emissions of criteria and air-toxic contaminants from in-use, light-duty low-emission vehicles (LEVs). EPA recruited 25 LEVs in 2002 and measured emissions on a chassis dynamometer using the cold-start urban dynamometer driving schedule of the Federal Test Procedure. The emissions measured included regulated pollutants, particulate matter, speciated hydrocarbon compounds, and carbonyl compounds. The results provided a comparison of emissions from real-world LEVs with emission standards for criteria and air-toxic compounds. Emission measurements indicated that a portion of the in-use fleet tested exceeded standards for the criteria gases. Real-time regulated and speciated hydrocarbon measurements demonstrated that the majority of emissions occurred during the initial phases of the cold-start portion of the urban dynamometer driving schedule. Overall, the study provided updated emission factor data for real-world, in-use operation of LEVs for improved emissions modeling and mobile source inventory development.

  9. Air

    Science.gov (United States)

    ... gov/ Home The environment and your health Air Air While we don’t often think about the ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be ...

  10. Measurement of toxic and related air pollutants. Proceedings of the 1994 U.S. EPA/A and WMA international symposium

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    The 1994 US Environmental Protection Agency/Air and Waste Management Association International Symposium: Measurement of Toxic and Related Air Pollutants was held May 2--6, 1994 in Durham, North Carolina. The four-day technical program consisted of 210 papers presented in twenty-four sessions plus a poster session with twenty papers. Individual papers focused on recent advances in the measurement and monitoring of toxic and related air pollutants in indoor and outdoor atmospheres. The program consisted of sessions on air pollution measurements of the OAQPS Enhanced Ozone Program, the Mount Mitchell Global Climate Change Program, the NC O 3 State Implementation Plan, Russian Air Pollution Studies, and Particles Studies, Quality Assurance and General Papers. Individual papers have been processed separately for inclusion in the appropriate data bases

  11. Screening methods for the development of air-toxics emission factors

    International Nuclear Information System (INIS)

    Bursey, J.T.

    1991-09-01

    Under the program the literature has been surveyed to determine the applicability of existing methodology. The primary goal was to use methodology applicable to the largest number of analytes listed in the Clean Air Act Amendments with the full realization that a broad coverage by a methodology may require some sacrifice of sensitivity and accuracy. The need for validation of proposed methodologies has been recognized. Assignments of analytes to a specific methodology have been made on the basis of previous validation studies and/or physical properties (available physical properties for the chemicals of the Clean Air Act list are supplied in an appendix). The range of applicability of a given sampling or analytical method, when available, is included as a part of the method description. Tables are included which summarize the potentially applicable sampling and analytical methods for chemicals listed in the Clean Air Act Amendments. General information on cost for the sampling and analysis procedures is presented

  12. Enhanced, multi criteria based site selection to measure mobile source toxic air pollutants

    Science.gov (United States)

    Research studies being conducted by the U.S. Environmental Protection Agency in collaboration with the U.S. Federal Highway Administration are designed to establish relationships between concentrations of highway vehicle air pollutants and variations in these concentrations as a ...

  13. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  14. Climate change air toxic co-reduction in the context of macroeconomic modelling.

    Science.gov (United States)

    Crawford-Brown, Douglas; Chen, Pi-Cheng; Shi, Hsiu-Ching; Chao, Chia-Wei

    2013-08-15

    This paper examines the health implications of global PM reduction accompanying greenhouse gas emissions reductions in the 180 national economies of the global macroeconomy. A human health effects module based on empirical data on GHG emissions, PM emissions, background PM concentrations, source apportionment and human health risk coefficients is used to estimate reductions in morbidity and mortality from PM exposures globally as co-reduction of GHG reductions. These results are compared against the "fuzzy bright line" that often underlies regulatory decisions for environmental toxics, and demonstrate that the risk reduction through PM reduction would usually be considered justified in traditional risk-based decisions for environmental toxics. It is shown that this risk reduction can be on the order of more than 4 × 10(-3) excess lifetime mortality risk, with global annual cost savings of slightly more than $10B, when uniform GHG reduction measures across all sectors of the economy form the basis for climate policy ($2.2B if only Annex I nations reduce). Consideration of co-reduction of PM-10 within a climate policy framework harmonized with other environmental policies can therefore be an effective driver of climate policy. An error analysis comparing results of the current model against those of significantly more spatially resolved models at city and national scales indicates errors caused by the low spatial resolution of the global model used here may be on the order of a factor of 2. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Assessing the influence of traffic-related air pollution on risk of term low birth weight on the basis of land-use-based regression models and measures of air toxics.

    Science.gov (United States)

    Ghosh, Jo Kay C; Wilhelm, Michelle; Su, Jason; Goldberg, Daniel; Cockburn, Myles; Jerrett, Michael; Ritz, Beate

    2012-06-15

    Few studies have examined associations of birth outcomes with toxic air pollutants (air toxics) in traffic exhaust. This study included 8,181 term low birth weight (LBW) children and 370,922 term normal-weight children born between January 1, 1995, and December 31, 2006, to women residing within 5 miles (8 km) of an air toxics monitoring station in Los Angeles County, California. Additionally, land-use-based regression (LUR)-modeled estimates of levels of nitric oxide, nitrogen dioxide, and nitrogen oxides were used to assess the influence of small-area variations in traffic pollution. The authors examined associations with term LBW (≥37 weeks' completed gestation and birth weight pollution in epidemiologic birth outcome studies.

  16. Heme oxygenase-1 protects endothelial cells from the toxicity of air pollutant chemicals

    International Nuclear Information System (INIS)

    Lawal, Akeem O.; Zhang, Min; Dittmar, Michael; Lulla, Aaron; Araujo, Jesus A.

    2015-01-01

    Diesel exhaust particles (DEPs) are a major component of diesel emissions, responsible for a large portion of their toxicity. In this study, we examined the toxic effects of DEPs on endothelial cells and the role of DEP-induced heme oxygenase-1 (HO-1) expression. Human microvascular endothelial cells (HMECs) were treated with an organic extract of DEPs from an automobile engine (A-DEP) or a forklift engine (F-DEP) for 1 and 4 h. ROS generation, cell viability, lactate dehydrogenase leakage, expression of HO-1, inflammatory genes, cell adhesion molecules and unfolded protein respone (UPR) gene were assessed. HO-1 expression and/or activity were inhibited by siRNA or tin protoporphyrin (Sn PPIX) and enhanced by an expression plasmid or cobalt protoporphyrin (CoPPIX). Exposure to 25 μg/ml of A-DEP and F-DEP significantly induced ROS production, cellular toxicity and greater levels of inflammatory and cellular adhesion molecules but to a different degree. Inhibition of HO-1 enzymatic activity with SnPPIX and silencing of the HO-1 gene by siRNA enhanced DEP-induced ROS production, further decreased cell viability and increased expression of inflammatory and cell adhesion molecules. On the other hand, overexpression of the HO-1 gene by a pcDNA 3.1D/V5-HO-1 plasmid significantly mitigated ROS production, increased cell survival and decreased the expression of inflammatory genes. HO-1 expression protected HMECs from DEP-induced prooxidative and proinflammatory effects. Modulation of HO-1 expression could potentially serve as a therapeutic target in an attempt to inhibit the cardiovascular effects of ambient PM. - Highlights: • We examined the role of HO-1 expression on diesel exhaust particle (DEP) in endothelial cells. • DEPs exert cytotoxic and inflammatory effects on human microvascular endothelial cells (HMECs). • DEPs induce HO-1 expression in HMECs. • HO-1 protects against the oxidative stress induced by DEps. • HO-1 attenuates the proinflammatory effects

  17. Toxic fear: the management of uncertainty in the wake of the Amsterdam air crash.

    Science.gov (United States)

    Boin, A; van Duin, M; Heyse, L

    2001-12-14

    This paper examines the management of uncertainty among emergency responders, the media, and the public following the crash of an Israeli cargo plane carrying apparently hazardous cargo in Amsterdam's Bijlmermeer area. While the authorities' management of the emergency created by the initial crash was effective, the long-term crisis management performance was considerably less effective. It is argued that, particularly in hazardous materials emergencies, considerable management attention is required in the long-term aftermath rather than seeking a quick declaration of "all clear" or determination that the crisis is over. This paper examines the roles of all actors in the crisis and addresses the nature of communications in the "disaster after the disaster". The evolution of a "toxic fear" among citizens is documented and the social psychology of crisis management in the aftermath is examined.

  18. Intermedia transfer factors for fifteen toxic pollutants released to air basins in California

    Energy Technology Data Exchange (ETDEWEB)

    McKone, T.E.; Daniels, J.I. [Lawrence Livermore National Lab., CA (United States); Chiao, F.F.; Hsieh, D.P.H. [Univ. of California, Davis, CA (United States)

    1993-10-01

    This report provides a summary definition of the intermedia-transfer factors (ITFs). Methods are discussed for estimating these parameters in the absence of measured values, and the estimation errors inherent in these estimation methods are considered. A detailed summary is provided of measured and estimated ITF values for fifteen air contaminants. They include: 1,3 butadiene; cadmium; cellosolve; cellosolve acetate; chloroform; di-2-ethylhexylphthalate; 1,4-dioxame; hexachlorobenzene; inorganic arsenic; inorganic lead; nickel; tetrachloroethylene; toluene; toluene-2,4-diisocyanate; and 1,3-xylene. Recommendations are made regarding the expected value and variance in these values for use in exposure models.

  19. Using silver nano particles for sampling of toxic mercury vapors from industrial air sample

    Directory of Open Access Journals (Sweden)

    M. Osanloo

    2014-05-01

    .Conclusion: The presented adsorbent is very useful for sampling of the trace amounts of mercury vapors from air. Moreover, it can be regenerated easily is suitable or sampling at 25 to 70 °C. Due to oxidation of silver and reduction in uptake of nanoparticles, oven temperature of 245 °C is used for the recovery of metallic silver. Low amount of adsorbent, high absorbency, high repeatability for sampling, low cost and high accuracy are of the advantages of the presented method.

  20. Real time measurement of transient event emissions of air toxics by tomographic remote sensing in tandem with mobile monitoring

    Science.gov (United States)

    Olaguer, Eduardo P.; Stutz, Jochen; Erickson, Matthew H.; Hurlock, Stephen C.; Cheung, Ross; Tsai, Catalina; Colosimo, Santo F.; Festa, James; Wijesinghe, Asanga; Neish, Bradley S.

    2017-02-01

    During the Benzene and other Toxics Exposure (BEE-TEX) study, a remote sensing network based on long path Differential Optical Absorption Spectroscopy (DOAS) was set up in the Manchester neighborhood beside the Ship Channel of Houston, Texas in order to perform Computer Aided Tomography (CAT) scans of hazardous air pollutants. On 18-19 February 2015, the CAT scan network detected large nocturnal plumes of toluene and xylenes most likely associated with railcar loading and unloading operations at Ship Channel petrochemical facilities. The presence of such plumes during railcar operations was confirmed by a mobile laboratory equipped with a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), which measured transient peaks of toluene and C2-benzenes of 50 ppb and 57 ppb respectively around 4 a.m. LST on 19 February 2015. Plume reconstruction and source attribution were performed using the 4D variational data assimilation technique and a 3D micro-scale forward and adjoint air quality model based on both tomographic and PTR-MS data. Inverse model estimates of fugitive emissions associated with railcar transfer emissions ranged from 2.0 to 8.2 kg/hr for toluene and from 2.2 to 3.5 kg/hr for xylenes in the early morning of 19 February 2015.

  1. Mortality among population with exposure to industrial air pollution containing nickel and other toxic metals.

    Science.gov (United States)

    Pasanen, Kari; Pukkala, Eero; Turunen, Anu W; Patama, Toni; Jussila, Ilkka; Makkonen, Sari; Salonen, Raimo O; Verkasalo, Pia K

    2012-05-01

    To assess disease mortality among people with exposure to metal-rich particulate air pollution. We conducted a cohort study on mortality from 1981 to 2005 among 33,573 people living near a nickel/copper smelter in Harjavalta, Finland. Nickel concentration in soil humus was selected as an indicator for long-term exposure. Relative risks--adjusted for age, socioeconomic status, and calendar period--were calculated for three exposure zones. The relative risks for diseases of the circulatory system by increasing exposure were 0.93 (95% confidence interval = 0.79 to 1.09), 1.20 (1.04 to 1.39), and 1.18 (1.00 to 1.39) among men and 1.01 (0.88 to 1.17), 1.20 (1.04 to 1.38), and 1.14 (0.97 to 1.33) among women. Exclusion of smelter workers from the cohort did not materially change the results. Long-term environmental exposure to metal-rich air pollution was associated with increased mortality from circulatory diseases.

  2. Auditing of sampling methods for air toxics at coal-fired power plants

    International Nuclear Information System (INIS)

    Agbede, R.O.; Clements, J.L.; Grunebach, M.G.

    1995-01-01

    Advanced Technology Systems, Inc. (ATS) with subcontract assistance from international Technology Corporation (IT) has provided external audit activities for Phase II of the Department of Energy-Pittsburgh Energy Technology Center's air emission test program. The objective of the audits is to help ensure that the data obtained from the emission tests are precise, accurate, representative, scientifically sound and legally defensible. This paper presents the criteria that were used to perform the external audits of the emission test program. It also describes the approach used by ATS and It in performing their audits. Examples of findings of the audits along with the actions take to correct problems and the subsequent effect of those actions on the test data are presented. The results of audit spikes performed at the Plant 1 test site are also discussed

  3. Sampling of power plant stacks for air toxic emissions: Topical report for Phases 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-21

    Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions.

  4. Auditing of sampling methods for air toxics at coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Agbede, R.O.; Clements, J.L.; Grunebach, M.G. [Advanced Technology Systems, Inc., Monroeville, PA (United States)] [and others

    1995-11-01

    Advanced Technology Systems, Inc. (ATS) with subcontract assistance from international Technology Corporation (IT) has provided external audit activities for Phase II of the Department of Energy-Pittsburgh Energy Technology Center`s air emission test program. The objective of the audits is to help ensure that the data obtained from the emission tests are precise, accurate, representative, scientifically sound and legally defensible. This paper presents the criteria that were used to perform the external audits of the emission test program. It also describes the approach used by ATS and It in performing their audits. Examples of findings of the audits along with the actions take to correct problems and the subsequent effect of those actions on the test data are presented. The results of audit spikes performed at the Plant 1 test site are also discussed.

  5. Air-quality monitoring at toxic waste sites: A Hanford perspective

    International Nuclear Information System (INIS)

    Laws, G.L.; Glantz, C.S.

    1990-01-01

    Air-quality monitoring is part of remedial investigation (RI) activities at waste sites in the 1,100-EM-1 Operable Unit on the U.S. Department of Energy's Hanford Site. Sampling is being conducted for volatile organic compounds, semivolatile organic compounds (including pesticides and polychlorinated biphenyls), metals, and asbestos. Monitoring will be conducted in three phases: before, during, and after intrusive RI activities. Battery-powered monitoring equipment is positioned at one location upwind of each site (to measure background) and, typically, at two locations downwind. Control samples identify contamination that may occur during handling or analysis. All samples are analyzed by approved U.S. Environmental Protection Agency methods. Results from the first monitoring have been assessed and are being used to upgrade sampling and laboratory analysis procedures

  6. REAL-TIME EMISSION CHARACTERIZATION OF ORGANIC AIR TOXIC POLLUTANTS DURING STEADY STATE AND TRANSIENT OPERATION OF A MEDIUM DUTY DIESEL ENGINE

    Science.gov (United States)

    An on-line monitoring method, jet resonance-enhanced multi-photon ionization (REMPI) with time-of-flight mass spectrometry (TOFMS) was used to measure emissions of organic air toxics from a medium-duty (60 kW)diesel generator during transient and steady state operations. Emission...

  7. Inducible Nitric Oxide Synthase Promoter Haplotypes and Residential Traffic-Related Air Pollution Jointly Influence Exhaled Nitric Oxide Level in Children.

    Directory of Open Access Journals (Sweden)

    Muhammad T Salam

    Full Text Available Exhaled nitric oxide (FeNO, a biomarker of airway inflammation, predicts asthma risk in children. We previously found that the promoter haplotypes in inducible nitric oxide synthase (NOS2 and exposure to residential traffic independently influence FeNO level. Because NOS2 is inducible by environmental exposures such as traffic-related exposure, we tested the hypothesis that common NOS2 promoter haplotypes modulate the relationship between residential traffic-related exposure and FeNO level in children.In a cross-sectional population-based study, subjects (N = 2,457; 7-11 year-old were Hispanic and non-Hispanic white children who participated in the Southern California Children's Health Study and had FeNO measurements. For residential traffic, lengths of local roads within circular buffers (50m, 100m and 200m radii around homes around the subjects' homes were estimated using geographic information system (GIS methods. We interrogated the two most common NOS2 promoter haplotypes that were found to affect FeNO level.The relationship between local road lengths within 100m and 200m circular buffers and FeNO level varied significantly by one of the NOS2 promoter haplotypes (P-values for interaction between road length and NOS2 promoter haplotype = 0.02 and 0.03, respectively. In children who had ≤250m of local road lengths within 100m buffer around their homes, those with two copies of the haplotype had significantly lower FeNO (adjusted geometric mean = 11.74ppb; 95% confidence intervals (CI: 9.99 to 13.80 than those with no copies (adjusted geometric mean = 15.28ppb; 95% CI: 14.04 to 16.63 with statistically significant trend of lower FeNO level with increasing number of haplotype copy (P-value for trend = 0.002. In contrast, among children who had >250m of local road lengths within 100m buffer, FeNO level did not significantly differ by the haplotype copy-number (P-value for trend = 0.34. Similar interactive effects of this haplotype and local

  8. Sampling of power plant stacks for air toxic emissions: Final report for Phases 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-28

    A test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPs) was conducted . Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical characterization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions. Field testing was conducted in two phases. The Phase I field program was performed over the period of August 24 through September 20, 1992, at the Tennessee Valley Authority Widows Creek Unit 8 Power Station, located near Stevenson (Jackson County), Alabama, on the Tennessee River. Sampling activities for Phase II were conducted from September 11 through October 14, 1993. Widows Creek Unit 8 is a 575-megawatt plant that uses bituminous coal averaging 3.7% sulfur and 13% ash. Downstream of the boiler, a venture wet scrubbing system is used for control of both sulfur dioxide and particulate emissions. There is no electrostatic precipitator (ESP) in this system. This system is atypical and represents only about 5% of the US utility industry. However, this site was chosen for this study because of the lack of information available for this particulate emission control system.

  9. Acute Toxicity of the Pesticides, Dichlorvos and Lindane against the African air-breathing catfish, Heterobranchus longifilis, Valenciennes, 1840 (Siluriformes: Clariidae).

    Science.gov (United States)

    Blessing, Oribhabor; Grace, Ikeogu C

    2016-07-25

    This study raises the awareness to the use of toxic pesticides and reiterates the well-known danger of these pesticides. The acute toxicity of two pesticides, dichlorvos and lindane against the African air-breathing catfish, Heterobranchus longifilis fingerlings was investigated under static bioassay in the laboratory. Relevant patents relating to acute toxicity of pesticides against fish were reviewed. Invention concerning the detection of biomarkers in material from a living organism relates to a method of testing whether a living organism has been exposed to stress, such as pesticide exposure. Range finding bioassays were conducted to get the range of concentrations for the definitive bioassays. The range of concentrations of test media for dichlorvos was 0.2 - 1.5 mg l-1 while that of lindane was 35 - 80 mg l-1. The median lethal concentrations were determined using probit analysis. The test pesticides were found to be differentially toxic to the test species. The 96h LC50 values of 0.8187 and 41.566 mg l-1 for dichlorvos and lindane respectively indicated that dichlorvos was highly toxic while lindane was slightly toxic to the test species. Computed toxicity factor showed that dichlorvos was 50.8 times more toxic than lindane. The unpaired t-test showed that dichlorvos was significantly (p < 0.05) more toxic than lindane. The physical and chemical parameters data showed that over the 96h periods, the test pesticides caused slight increase in temperature, dissolved oxygen and ammonia of the test media, when compared with the untreated control. But they differentially altered pH, conductivity and alkalinity. Since H. longifilis is sensitive to the test pesticides, it can therefore be considered as a good test species for the determination of acute toxicity and poisoning resulting from the pesticides and possibly for other compounds with similar intrinsic characteristics.

  10. Effects on annual cost of solar/air-heat utilization system of carbon tax and interest rate for a residential house; Jutakuyo taiyo/taikinetsu riyo system no nenkan keihi ni oyobosu tansozei kinri no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Q.; Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru National College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan). Faculty of Engineering

    1996-10-27

    In recent years, a system has been proposed that utilizes river heat, air-heat, exhaust heat from a cooler, etc., in addition to natural energy for the heat pump. With the introduction of such system, the amount of energy used and that of CO2 exhaust will be greatly reduced, but annual expenses will be increased as it stands. In order to improve the cost efficiency of the system, a proposal has been made for the introduction of an economic policy such as the carbon tax and a low interest financing system. With these matters in the background, the subject study predicts the production of solar cells in the future and, on the basis of this production, determines the price, conversion efficiency and equipment energy of solar cells in the future. Using these values and taking into consideration the introduction of the carbon tax and the low interest financing system, the optimum area was determined for solar cells and heat concentrators in a future residential solar/air-heat energy system. The carbon tax, being imposed on all CO2 discharges, had a large effect. Moreover, as the tax increased, annual expenses decreased for the solar/air-heat system. 3 refs., 6 figs.

  11. Lung toxicity determination by in vitro exposure at the air liquid interface with an integrated online dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Muelhopt, Sonja; Paur, H-R [Institute for Technical Chemistry, Thermal Waste Treatment Division, Forschungszentrum Karlsruhe GmbH, 76021, Karlsruhe (Germany); Diabate, S; Weiss, C [Institute for Toxicology and Genetics, Forschungszentrum Karlsruhe GmbH, 76021, Karlsruhe (Germany); Krebs, T [VITROCELL Systems GmbH, 79183, Waldkirch (Germany)], E-mail: muelhopt@itc-tab.fzk.de

    2009-05-01

    Epidemiological studies show an association between the concentration of ultrafine particles in the atmosphere and the rate of mortality or morbidity due to respiratory and cardiovascular diseases. For the quantitative assessment of the toxicity of airborne nanoparticles the dose-response relationship is tested in in vitro test systems using bioassays of cell cultures as sensor. For the air-liquid interface exposure of cell cultures towards aerosols the Karlsruhe exposure system was developed. The human lung cell cultures are exposed in VITROCELL (registered) system modules with a constant flow of the conditioned aerosol. After exposure the cells are analyzed to measure the biological responses such as viability, inflammatory or oxidative stress. For the determination of the dose response relationship the accurate knowledge of the deposited particle mass is essential. A new online method is developed in the Karlsruhe exposure system: the sensor of a quartz crystal microbalance is placed in an exposure chamber instead of the membrane insert and exposed to the aerosol in the same way as the cell cultures. The deposited mass per area unit is monitored as a function of exposure time showing a linear relationship for a constant aerosol flow with defined particle concentration. A comparison of this new dose signal to a dosimetry method using fluorescein sodium particles shows a very good correlation between the sensor signal of the quartz crystal microbalance and the deposited mass on the membranes shown by spectroscopy. This system for the first time provides an online dose measurement for in vitro experiments with nanoparticles.

  12. Lung toxicity determination by in vitro exposure at the air liquid interface with an integrated online dose measurement

    International Nuclear Information System (INIS)

    Muelhopt, Sonja; Paur, H-R; Diabate, S; Weiss, C; Krebs, T

    2009-01-01

    Epidemiological studies show an association between the concentration of ultrafine particles in the atmosphere and the rate of mortality or morbidity due to respiratory and cardiovascular diseases. For the quantitative assessment of the toxicity of airborne nanoparticles the dose-response relationship is tested in in vitro test systems using bioassays of cell cultures as sensor. For the air-liquid interface exposure of cell cultures towards aerosols the Karlsruhe exposure system was developed. The human lung cell cultures are exposed in VITROCELL (registered) system modules with a constant flow of the conditioned aerosol. After exposure the cells are analyzed to measure the biological responses such as viability, inflammatory or oxidative stress. For the determination of the dose response relationship the accurate knowledge of the deposited particle mass is essential. A new online method is developed in the Karlsruhe exposure system: the sensor of a quartz crystal microbalance is placed in an exposure chamber instead of the membrane insert and exposed to the aerosol in the same way as the cell cultures. The deposited mass per area unit is monitored as a function of exposure time showing a linear relationship for a constant aerosol flow with defined particle concentration. A comparison of this new dose signal to a dosimetry method using fluorescein sodium particles shows a very good correlation between the sensor signal of the quartz crystal microbalance and the deposited mass on the membranes shown by spectroscopy. This system for the first time provides an online dose measurement for in vitro experiments with nanoparticles.

  13. Training Munitions Health Risk Assessment No. 39-EJ-1485-00. Residential Exposure from Inhalation of Air Emissions from the M33 .50 Caliber Ball Cartridge

    National Research Council Canada - National Science Library

    Coakley, Stafford

    2001-01-01

    ... .50 Caliber Ball Cartridge. This document present the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  14. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M80 7.62-MM Ball Cartridge

    National Research Council Canada - National Science Library

    Chang, Hsieng-Ye

    2001-01-01

    ... of the 7.62 mm Ball Cartridge. This document presents the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  15. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M855 5.56-MM Ball Cartridge

    National Research Council Canada - National Science Library

    Mobley, Joleen

    2001-01-01

    .... This document present the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  16. STAR Measurements and Modeling for Quantifying Air Quality and Climatic Impacts of Residential Biomass or Coal Combustion for Cooking, Heating and Lighting Kick-off Meeting

    Science.gov (United States)

    STAR grantees and EPA scientists will discuss progress on their projects which aim to quantify the extent to which interventions for cleaner cooking, heating, or lighting can impact air quality and climate, which in turn affect human health and welfare

  17. Methods for regionalization of impacts of non-toxic air pollutants in life-cycle assessments often tell a consistent story

    DEFF Research Database (Denmark)

    Djomo, Sylvestre Njakou; Knudsen, Marie Trydeman; Andersen, Mikael Skou

    2017-01-01

    , and accurate estimates of CFs are crucial for establishing long-term, sustainable air pollution abatement policies. We reviewed currently available studies on the regionalization of non-toxic air pollutants in LCA. We also extracted and converted data into indices for analysis. We showed that CFs can...... are the results of the models used, category definitions, soil sensitivity factors, background emission concentration, critical loads database, and input data. Striking features in these studies were the lack of CFs for countries outside Europe, the USA, Japan, and Canada, the lack of quantification...

  18. Toxic deposition monitoring network data listing for organochlorine pesticides and polychlorinated biphenyls in air and precipitation, 1989 and 1990. Report No. ARB-107-92

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    The toxic deposition network was established in late 1987 to monitor for polychlorinated biphenyls (PCBs), organochlorine pesticides (OCs), trace metals, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated dibenzo-dioxins and dibenzo-furans (PCDD/PCDFs) in air and precipitation. This report gives the 1989 and 1990 air and precipitation monitoring results for PCBs and OCs. Data from the site at Shallow Lake are incomplete because the site was closed in October 1990. Trace metal data are reported as part of the APIOS monitoring program.

  19. Residential Radon Exposure and Risk of Lung Cancer in Missouri

    Science.gov (United States)

    A case-control study of lung cancer and residential radon exposure in which investigators carried out both standard year-long air measurements and CR-39 alpha detector measurements (call surface monitors)

  20. Separation of special toxic substances from the air and incinerator of offgas streams, especially of radioactive iodine and polycyclic carbon hydrogens

    International Nuclear Information System (INIS)

    Nikoopour-Deylami, A.H.

    1981-11-01

    In the first part of the thesis, the adsorption of radioiodine and methyliodide on different kinds of active charcoal was studied. It was observed that untreated charcoal retains radioiodine sufficiently, while organic compounds as methyliodid could be adsorbed after pretreating with triethylenediamine even at high air velocities. In the presence of moisture in the air the efficiency dropped down to 30% of the original value. In the second part of the work an apparatus using sandfilter columns for the separation of toxic substances and thermochrome column for marking the temperature intervals was developed and posted at different places in athe filtering system of an incineration plant. After extraction of the polycyclic aromates with benzene from the column and chemical separation, the neutral fraction was split by a silicagel column and 14 toxic aromates identified by gas chromatography. It could be proven that 97 +- 2% of the polycyclic aromates were retained by the existing ceramic filter systems. (Author)

  1. Component modeling in ecological risk assessment: Disturbance in interspecific interactions caused by air toxics introduced into terrestrial ecosystems

    Science.gov (United States)

    Swider, Jan Zenon

    Ecological Risk Assessment standpoint and examine the impact of air toxics emissions on an ecosystem, with particular emphasis on predator-prey interactions. Such analysis may help to identify the most likely conditions leading to the ecosystem instability and possibility of its recuperation.

  2. Correlation between air flow rate and pollutant concentrations during two-stage oak log combustion in a 25 KW residential boiler

    Directory of Open Access Journals (Sweden)

    Juszczak Marek

    2016-09-01

    Full Text Available It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.

  3. Apply Woods Model in the Predictions of Ambient Air Particles and Metallic Elements (Mn, Fe, Zn, Cr, and Cu at Industrial, Suburban/Coastal, and Residential Sampling Sites

    Directory of Open Access Journals (Sweden)

    Guor-Cheng Fang

    2012-01-01

    Full Text Available The main purpose for this study was to monitor ambient air particles and metallic elements (Mn, Fe, Zn, Cr, and Cu in total suspended particulates (TSPs concentration, dry deposition at three characteristic sampling sites of central Taiwan. Additionally, the calculated/measured dry deposition flux ratios of ambient air particles and metallic elements were calculated with Woods models at these three characteristic sampling sites during years of 2009-2010. As for ambient air particles, the results indicated that the Woods model generated the most accurate dry deposition prediction results when particle size was 18 μm in this study. The results also indicated that the Woods model exhibited better dry deposition prediction performance when the particle size was greater than 10 μm for the ambient air metallic elements in this study. Finally, as for Quan-xing sampling site, the main sources were many industrial factories under process around these regions and were severely polluted areas. In addition, the highest average dry deposition for Mn, Fe, Zn, and Cu species occurred at Bei-shi sampling site, and the main sources were the nearby science park, fossil fuel combustion, and Taichung thermal power plant (TTPP. Additionally, as for He-mei sampling site, the main sources were subjected to traffic mobile emissions.

  4. Hazardous air pollutants

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This chapter presents an overview of the requirements of Title 3 of the 1990 Amendments to the Clean Air Act. The following topics are included: listed air toxics; sources covered by the program; standards for regulation of air toxics; area source program; air toxics permit program; prevention of accidental releases; and duties of the Risk Assessment and Management Commission

  5. Air Toxics Under the Big Sky: Examining the Effectiveness of Authentic Scientific Research on High School Students' Science Skills and Interest.

    Science.gov (United States)

    Ward, Tony J; Delaloye, Naomi; Adams, Earle Raymond; Ware, Desirae; Vanek, Diana; Knuth, Randy; Hester, Carolyn Laurie; Marra, Nancy Noel; Holian, Andrij

    2016-01-01

    Air Toxics Under the Big Sky is an environmental science outreach/education program that incorporates the Next Generation Science Standards (NGSS) 8 Practices with the goal of promoting knowledge and understanding of authentic scientific research in high school classrooms through air quality research. A quasi-experimental design was used in order to understand: 1) how the program affects student understanding of scientific inquiry and research and 2) how the open inquiry learning opportunities provided by the program increase student interest in science as a career path . Treatment students received instruction related to air pollution (airborne particulate matter), associated health concerns, and training on how to operate air quality testing equipment. They then participated in a yearlong scientific research project in which they developed and tested hypotheses through research of their own design regarding the sources and concentrations of air pollution in their homes and communities. Results from an external evaluation revealed that treatment students developed a deeper understanding of scientific research than did comparison students, as measured by their ability to generate good hypotheses and research designs, and equally expressed an increased interest in pursuing a career in science. These results emphasize the value of and need for authentic science learning opportunities in the modern science classroom.

  6. CAirTOX: A compartment model for assessing the fate of and human exposure to toxic-chemical emissions to air

    Energy Technology Data Exchange (ETDEWEB)

    McKone, T.E.

    1993-10-01

    CAirTOX has been developed as a spreadsheet model to assist in making a risk assessment of toxic air emissions. With CAirTOX, one can address how contaminants released to an air basin can lead to contamination of soil, food, surface water, and sediments. The modeling effort includes a multimedia transport and transformation model, exposure scenario models, and efforts to quantify uncertainty in multimedia, multiple-pathway exposure assessments. The multimedia transport and transformation model is a steady-state, but non-equilibrium model that can be used to assess concentrations of contaminants released continuously to air. In Part 1, the authors describe the multimedia transport and transformation model used to determine the fate of air emissions. In Part 2, they describe inputs and data needs for CAirTOX and the development of a set of landscape factors, which can be used to represent regional air basin/water-shed systems in California. In Part 3, they describe the multiple-pathway exposure scenarios and exposure algorithms. In Part 4, they compare the HRA approach and results and the CAirTOX exposure equations. In Part 5, they consider model sensitivity and uncertainty to determine how variability and uncertainty in model inputs affects the precision, accuracy, and credibility of the model output.

  7. Air Toxics Under the Big Sky: Examining the Effectiveness of Authentic Scientific Research on High School Students’ Science Skills and Interest

    Science.gov (United States)

    Delaloye, Naomi; Adams, Earle Raymond; Ware, Desirae; Vanek, Diana; Knuth, Randy; Hester, Carolyn Laurie; Marra, Nancy Noel; Holian, Andrij

    2016-01-01

    Air Toxics Under the Big Sky is an environmental science outreach/education program that incorporates the Next Generation Science Standards (NGSS) 8 Practices with the goal of promoting knowledge and understanding of authentic scientific research in high school classrooms through air quality research. A quasi-experimental design was used in order to understand: 1) how the program affects student understanding of scientific inquiry and research and 2) how the open inquiry learning opportunities provided by the program increase student interest in science as a career path. Treatment students received instruction related to air pollution (airborne particulate matter), associated health concerns, and training on how to operate air quality testing equipment. They then participated in a yearlong scientific research project in which they developed and tested hypotheses through research of their own design regarding the sources and concentrations of air pollution in their homes and communities. Results from an external evaluation revealed that treatment students developed a deeper understanding of scientific research than did comparison students, as measured by their ability to generate good hypotheses and research designs, and equally expressed an increased interest in pursuing a career in science. These results emphasize the value of and need for authentic science learning opportunities in the modern science classroom. PMID:28286375

  8. Air Toxics Under the Big Sky: examining the effectiveness of authentic scientific research on high school students' science skills and interest

    Science.gov (United States)

    Ward, Tony J.; Delaloye, Naomi; Adams, Earle Raymond; Ware, Desirae; Vanek, Diana; Knuth, Randy; Hester, Carolyn Laurie; Marra, Nancy Noel; Holian, Andrij

    2016-04-01

    Air Toxics Under the Big Sky is an environmental science outreach/education program that incorporates the Next Generation Science Standards (NGSS) 8 Practices with the goal of promoting knowledge and understanding of authentic scientific research in high school classrooms through air quality research. This research explored: (1) how the program affects student understanding of scientific inquiry and research and (2) how the open-inquiry learning opportunities provided by the program increase student interest in science as a career path. Treatment students received instruction related to air pollution (airborne particulate matter), associated health concerns, and training on how to operate air quality testing equipment. They then participated in a yearlong scientific research project in which they developed and tested hypotheses through research of their own design regarding the sources and concentrations of air pollution in their homes and communities. Results from an external evaluation revealed that treatment students developed a deeper understanding of scientific research than did comparison students, as measured by their ability to generate good hypotheses and research designs, and equally expressed an increased interest in pursuing a career in science. These results emphasize the value of and need for authentic science learning opportunities in the modern science classroom.

  9. Speciated VOC Emissions from an Outdoor Residential Pellet burning Hydronic Heater

    Science.gov (United States)

    Outdoor hydronic heaters used for residential heating emit air pollutants such as particulate matter and volatile organic compounds (VOCs), which can lead to deleterious impacts on local air quality and human health. Detailed speciated emissions measurements are required to accur...

  10. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  11. Residential heat pumps in the future Danish energy system

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    Denmark is striving towards 100% renewable energy system in 2050. Residential heat pumps are expected to be a part of that system.We propose two novel approaches to improve the representation of residential heat pumps: Coefficients of performance (COPs) are modelled as dependent on air and ground...... temperature while installation of ground-source heat pumps is constrained by available ground area. In this study, TIMES-DK model is utilised to test the effects of improved modelling of residential heat pumps on the Danish energy system until 2050.The analysis of the Danish energy system was done...... for politically agreed targets which include: at least 50% of electricity consumption from wind power starting from 2020, fossil fuel free heat and power sector from 2035 and 100% renewable energy system starting from 2050. Residential heat pumps supply around 25% of total residential heating demand after 2035...

  12. Control of Toxic Chemicals in Puget Sound, Phase 3: Study of Atmospheric Deposition of Air Toxics to the Surface of Puget Sound

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M.; Louchouarn, Patrick; Kuo, Li-Jung; Crecelius, Eric A.; Cullinan, Valerie I.; Gill, Gary A.; Garland, Charity R.; Williamson, J. B.; Dhammapala, R.

    2010-07-05

    The results of the Phase 1 Toxics Loading study suggested that runoff from the land surface and atmospheric deposition directly to marine waters have resulted in considerable loads of contaminants to Puget Sound (Hart Crowser et al. 2007). The limited data available for atmospheric deposition fluxes throughout Puget Sound was recognized as a significant data gap. Therefore, this study provided more recent or first reported atmospheric deposition fluxes of PAHs, PBDEs, and select trace elements for Puget Sound. Samples representing bulk atmospheric deposition were collected during 2008 and 2009 at seven stations around Puget Sound spanning from Padilla Bay south to Nisqually River including Hood Canal and the Straits of Juan de Fuca. Revised annual loading estimates for atmospheric deposition to the waters of Puget Sound were calculated for each of the toxics and demonstrated an overall decrease in the atmospheric loading estimates except for polybrominated diphenyl ethers (PBDEs) and total mercury (THg). The median atmospheric deposition flux of total PBDE (7.0 ng/m2/d) was higher than that of the Hart Crowser (2007) Phase 1 estimate (2.0 ng/m2/d). The THg was not significantly different from the original estimates. The median atmospheric deposition flux for pyrogenic PAHs (34.2 ng/m2/d; without TCB) shows a relatively narrow range across all stations (interquartile range: 21.2- 61.1 ng/m2/d) and shows no influence of season. The highest median fluxes for all parameters were measured at the industrial location in Tacoma and the lowest were recorded at the rural sites in Hood Canal and Sequim Bay. Finally, a semi-quantitative apportionment study permitted a first-order characterization of source inputs to the atmosphere of the Puget Sound. Both biomarker ratios and a principal component analysis confirmed regional data from the Puget Sound and Straits of Georgia region and pointed to the predominance of biomass and fossil fuel (mostly liquid petroleum products such

  13. Energy and IAQ Implications of Residential Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    This study evaluates the energy, humidity and indoor air quality (IAQ) implications of residential ventilation cooling in all U.S. IECC climate zones. A computer modeling approach was adopted, using an advanced residential building simulation tool with airflow, energy and humidity models. An economizer (large supply fan) was simulated to provide ventilation cooling while outdoor air temperatures were lower than indoor air temperatures (typically at night). The simulations were performed for a full year using one-minute time steps to allow for scheduling of ventilation systems and to account for interactions between ventilation and heating/cooling systems.

  14. Air

    CERN Document Server

    Rivera, Andrea

    2017-01-01

    Air is all around us. Learn how it is used in art, technology, and engineering. Five easy-to-read chapters explain the science behind air, as well as its real-world applications. Vibrant, full-color photos, bolded glossary words, and a key stats section let readers zoom in even deeper. Aligned to Common Core Standards and correlated to state standards. Abdo Zoom is a division of ABDO.

  15. Fact Sheet - Final Air Toxics Rule for Steel Pickling and HCI Process Facilities and Hydrochloric Acid Regeneration Plants

    Science.gov (United States)

    Fact Sheet summarizing the main points of the national emssions standard for hazaradous air pollutants (NESHAP) for Steel Pickling— HCl Process Facilities and Hydrochloric Acid Regeneration Plants as promulgated on June 22, 1999.

  16. Oil and Natural Gas Production Facilities & Natural Gas Transmission and Storage Facilities Final Air Toxics Rules Fact Sheet

    Science.gov (United States)

    This page contains a May 1999 fact sheet for the final National Emission Standards for Hazardous Air Pollutants (NESHAP) for Petroleum Refineries. This document provides a summary of the 1999 final rule.

  17. Final Air Toxics Standards for Clay Ceramics Manufacturing, Glass Manufacturing, and Secondary Nonferrous Metals Processing Area Sources Fact Sheet

    Science.gov (United States)

    This page contains a December 2007 fact sheet with information regarding the National Emissions Standards for Hazardous Air Pollutants (NESHAP) for Clay Ceramics Manufacturing, Glass Manufacturing, and Secondary Nonferrous Metals Processing Area Sources

  18. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  19. The visualization and dissemination of the Great Lakes Regional Toxic Air Emissions Inventory: Using geographic information systems and interactive Internet mapping applications

    Energy Technology Data Exchange (ETDEWEB)

    Conley, R.M. [Great Lakes Commission, Ann Arbor, MI (United States)

    1997-12-31

    The eight Great Lakes states, the Canadian province of Ontario and the Great Lakes Commission are involved in a collective effort to develop a regional inventory of toxic air emissions for 49 targeted toxic pollutants from point and area sources. The regional inventory will soon be expanded to include emissions from mobile sources. The inventory, when aggregated for all eight states and Ontario, will eventually reside at the US Environmental Protection Agency (EPA), Great Lakes National Program Office (GLNPO). To aid in the understanding and interpretation of the inventory`s data, an effort has been undertaken to generate two map series for the entire region: (1) choropleth maps of total toxic air emissions at the county level of geography and (2) dot maps showing facility locations. To ensure an effective and efficient dissemination process among the province and various states, an interactive Internet mapping interface prototype was modified and used for the project. With an interactive online visualization tool, the inventory collectors, managers and researchers can quickly and effectively view the inventory`s data on maps, charts or spreadsheets. These graphics can be used as: (1) a QA/QC function for the inventory collectors, (2) a simple communication of complex data to support managers decision making and (3) a means for easy access to complex data and information about any geographic area in the region for the researchers or general public. This paper describes the development and use of PC Arc/Info, ArcView and MapInfo geographic information systems (GIS), mapping and Internet interfacing applications to visualize, disseminate and convey the emissions inventory data in a meaningful and useful manner. The various methods developed and implemented to convert, process and prepare the inventory data and Internet interface for use with a standard Internet web browser also are described in this paper.

  20. Applying power electronics to residential HVAC

    International Nuclear Information System (INIS)

    Sulfstede, L.

    1991-01-01

    This paper outlines several of the market and application issues bearing on the economics residential variable speed air conditioners and heat pumps. Technical details of capacity modulized systems have been avoided, along with design issues and tradeoffs involving power semiconductors, motor torque and speed control strategies- and silicon integration for these applications. The intention is to provoke new creative technical solutions but perhaps more importantly, to involve new marketing strategies that will develop the mature potential of air conditioning products containing power electronics to enable them to generate the tough HVAC market, competing successfully against conventional systems

  1. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  2. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  3. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  4. Indoor Environment in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [°C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 °C. The temperature of the indoor environment is held at the optimum level (18-24 °C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.

  5. Perceived public health effects of occupational and residential ...

    African Journals Online (AJOL)

    High levels of environmental contamination can occur from e-waste processing, putting workers and residents in surrounding areas at risk as they are likely to be exposed to complex mixtures of unknown toxicity. This study was aimed at assessing the perceived public health effects of occupational and residential exposures ...

  6. Physical and chemical characterization of residential oil boiler emissions.

    Science.gov (United States)

    Hays, Michael D; Beck, Lee; Barfield, Pamela; Lavrich, Richard J; Dong, Yuanji; Vander Wal, Randy L

    2008-04-01

    The toxicity of emissions from the combustion of home heating oil coupled with the regional proximity and seasonal use of residential oil boilers (ROB) is an important public health concern. Yet scant physical and chemical information about the emissions from this source is available for climate and air quality modeling and for improving our understanding of aerosol-related human health effects. The gas- and particle-phase emissions from an active ROB firing distillate fuel oil (commonly known as diesel fuel) were evaluated to address this deficiency. Ion chromatography of impactor samples showed that the ultrafine ROB aerosol emissions were approximately 45% (w/w) sulfate. Gas chromatography-mass spectrometry detected various n-alkanes at trace levels, sometimes in accumulation mode particles, and out of phase with the size distributions of aerosol mass and sulfate. The carbonaceous matter in the ROB aerosol was primarily light-adsorbing elemental carbon. Gas chromatography-atomic emission spectroscopy measured a previously unrecognized organosulfur compound group in the ROB aerosol emissions. High-resolution transmission electron microscopy of ROB soot indicated the presence of a highly ordered primary particle nanostructure embedded in larger aggregates. Organic gas emissions were measured using EPA Methods TO-15 and TO-11A. The ROB emitted volatile oxygenates (8 mg/(kg of oil burned)) and olefins (5 mg/(kg of oil burned)) mostly unrelated to the base fuel composition. In the final analysis, the ROB tested was a source of numerous hazardous air pollutants as defined in the Clean Air Act Amendments. Approximations conducted using emissions data from the ROB tests show relatively low contributions to a regional-level anthropogenic emissions inventory for volitile organic compounds, PM2.5, and SO2 mass.

  7. Toxicity of a metal(loid)-polluted agricultural soil to Enchytraeus crypticus changes under a global warming perspective: Variations in air temperature and soil moisture content.

    Science.gov (United States)

    González-Alcaraz, M Nazaret; van Gestel, Cornelis A M

    2016-12-15

    This study aimed to assess how the current global warming perspective, with increasing air temperature (20°C vs. 25°C) and decreasing soil moisture content (50% vs. 30% of the soil water holding capacity, WHC), affected the toxicity of a metal(loid)-polluted agricultural soil to Enchytraeus crypticus. Enchytraeids were exposed for 21d to a dilution series of the agricultural soil with Lufa 2.2 control soil under four climate situations: 20°C+50% WHC (standard conditions), 20°C+30% WHC, 25°C+50% WHC, and 25°C+30% WHC. Survival, reproduction and bioaccumulation of As, Cd, Co, Cu, Fe, Mn, Ni, Pb and Zn were obtained as endpoints. Reproduction was more sensitive to both climate factors and metal(loid) pollution. High soil salinity (electrical conductivity~3dSm -1 ) and clay texture, even without the presence of high metal(loid) concentrations, affected enchytraeid performance especially at drier conditions (≥80% reduction in reproduction). The toxicity of the agricultural soil increased at drier conditions (10% reduction in EC10 and EC50 values for the effect on enchytraeid reproduction). Changes in enchytraeid performance were accompanied by changes in As, Fe, Mn, Pb and Zn bioaccumulation, with lower body concentrations at drier conditions probably due to greater competition with soluble salts in the case of Fe, Mn, Pb and Zn. This study shows that apart from high metal(loid) concentrations other soil properties (e.g. salinity and texture) may be partially responsible for the toxicity of metal(loid)-polluted soils to soil invertebrates, especially under changing climate conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Residential Segregation and Racial Cancer Disparities: A Systematic Review.

    Science.gov (United States)

    Landrine, Hope; Corral, Irma; Lee, Joseph G L; Efird, Jimmy T; Hall, Marla B; Bess, Jukelia J

    2017-12-01

    This paper provides the first review of empirical studies of segregation and black-white cancer disparities. We searched all years of PubMed (through May 2016) using these terms: racial segregation, residential segregation, neighborhood racial composition (first terms) and (second terms) cancer incidence, mortality, survival, stage at diagnosis, screening. The 17 (of 668) articles that measured both segregation and a cancer outcome were retained. Segregation contributed significantly to cancer and to racial cancer disparities in 70% of analyses, even after controlling for socioeconomic status and health insurance. Residing in segregated African-American areas was associated with higher odds of later-stage diagnosis of breast and lung cancers, higher mortality rates and lower survival rates from breast and lung cancers, and higher cumulative cancer risks associated with exposure to ambient air toxics. There were no studies of many types of cancer (e.g., cervical). Studies differed in their measure of segregation, and 40% used an invalid measure. Possible mediators of the segregation effect usually were not tested. Empirical analysis of segregation and racial cancer disparities is a recent area of research. The literature is limited to 17 studies that focused primarily on breast cancer. Studies differed in their measure of segregation, yet segregation nonetheless contributed to cancer and to racial cancer disparities in 70% of analyses. This suggests the need for further research that uses valid measures of segregation, examines a variety of types of cancers, and explores the variables that may mediate the segregation effect.

  9. MICRO-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Gerstmann

    2009-01-31

    This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

  10. Methodology to determine the consumption and potential of saving of electrical energy in the systems of air-conditioning in the residential sector: case the Northwest of Mexico; Metodologia para determinar el consumo y potencial de ahorro de energia electrica en los sistemas de climatizacion en el sector residencial: caso Noroeste de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rosas Flores, J. A.; Morillon Galvez, D.

    2008-07-01

    In this work there are studied the characteristics of the consumption of electrical residential energy due to the systems of air conditioning and to cos mell, in the region Northwest of Mexico (Sonora, Sinaloa, Baja California Norte, Baja California Sur, and Nayarit) and the North region (Coahuila, Chihuahua, Durango, Nuevo Leon). Between the principal results one finds that the potential saving of electrical energy, with base in the use of passive systems as the isolation of the housings, decided in 3,356 GWh (similar to the electrical annual supply that there needs the state of Durango or Guerrero). (Author)

  11. Presence of organophosphorus pesticide oxygen analogs in air samples

    Science.gov (United States)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  12. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  13. Metal contamination in environmental media in residential ...

    Science.gov (United States)

    Hard-rock mining for metals, such as gold, silver, copper, zinc, iron and others, is recognized to have a significant impact on the environmental media, soil and water, in particular. Toxic contaminants released from mine waste to surface water and groundwater is the primary concern, but human exposure to soil contaminants either directly, via inhalation of airborne dust particles, or indirectly, via food chain (ingestion of animal products and/or vegetables grown in contaminated areas), is also, significant. In this research, we analyzed data collected in 2007, as part of a larger environmental study performed in the Rosia Montana area in Transylvania, to provide the Romanian governmental authorities with data on the levels of metal contamination in environmental media from this historical mining area. The data were also considered in policy decision to address mining-related environmental concerns in the area. We examined soil and water data collected from residential areas near the mining sites to determine relationships among metals analyzed in these different environmental media, using the correlation procedure in SAS statistical software. Results for residential soil and water analysis indicate that the average values for arsenic (As) (85 mg/kg), cadmium (Cd) (3.2 mg/kg), mercury (Hg) (2.3 mg/kg) and lead (Pb) (92 mg/kg) exceeded the Romanian regulatory exposure levels [the intervention thresholds for residential soil in case of As (25 mg/kg) and Hg

  14. Guidelines for residential commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-31

    Currently, houses do not perform optimally or even as many codes and forecasts predict, largely because they are field assembled and there is no consistent process to identify problems or to correct them. Residential commissioning is a solution to this problem. This guide is the culmination of a 30-month project that began in September 1999. The ultimate objective of the project is to increase the number of houses that undergo commissioning, which will improve the quality, comfort, and safety of homes for California citizens. The project goal is to lay the groundwork for a residential commissioning industry in California focused on end-use energy and non-energy issues. As such, we intend this guide to be a beginning and not an end. Our intent is that the guide will lead to the programmatic integration of commissioning with other building industry processes, which in turn will provide more value to a single site visit for people such as home energy auditors and raters, home inspectors, and building performance contractors. Project work to support the development of this guide includes: a literature review and annotated bibliography, which facilitates access to 469 documents related to residential commissioning published over the past 20 years (Wray et al. 2000), an analysis of the potential benefits one can realistically expect from commissioning new and existing California houses (Matson et al. 2002), and an assessment of 107 diagnostic tools for evaluating residential commissioning metrics (Wray et al. 2002). In this guide, we describe the issues that non-experts should consider in developing a commissioning program to achieve the benefits we have identified. We do this by providing specific recommendations about: how to structure the commissioning process, which diagnostics to use, and how to use them to commission new and existing houses. Using examples, we also demonstrate the potential benefits of applying the recommended whole-house commissioning approach to

  15. Detailed residential electric determination

    Energy Technology Data Exchange (ETDEWEB)

    1984-06-01

    Data on residential loads has been collected from four residences in real time. The data, measured at 5-second intervals for 53 days of continuous operation, were statistically characterized. An algorithm was developed and incorporated into the modeling code SOLCEL. Performance simulations with SOLCEL using these data as well as previous data collected over longer time intervals indicate that no significant errors in system value are introduced through the use of long-term average data.

  16. Global design of a reversible air/water heat pump with variable power for the residential sector; Conception globale d'une pompe a chaleur air/eau inversable a puissance variable pour le secteur residentiel

    Energy Technology Data Exchange (ETDEWEB)

    Flach-Malaspina, N.

    2004-10-15

    Variable power is one of the means to improve the seasonal energy efficiency of heat pump space heating systems. The dual compressors technology is energetically efficient and is available in Europe. The main results of this work are: 1 - the identification of the origin of cycling losses in heating and cooling mode of existing mono-compressor air/water systems. The standby consumption of the heat pump is the only element which can efficiently contribute to reduce the energy losses at partial load. 2 - The quantification of the energy gains by adapting the dual compressors technology to a prototype of reference heat pump. 3 - A dynamic model of calculation of the seasonal coefficient of performance has been developed. 4 - The optimization of compressors operation and of the unfreezing system has permitted to increase the seasonal coefficient of performance from 14.7% to 18.6% with respect to the outdoor temperature. To carry out this study, design, experimental and modeling works have been done. The design of a heat pump fitted with two compressors has required the development of a new partial load testing bench. The several experimental and standardized tests have permitted to characterize an existing heat pump and a dual compressor heat pump whatever the operation mode and the outdoor climate. The dynamical model obtained has permitted to optimize the energy efficiency of the system thanks to a better management of the unfreezing system and to a proper regulation of the compressors. Some ways of improvement concern the dimensioning of compressors and the management of exchangers flow rates for an additional improvement of seasonal coefficients of performance. (J.S.)

  17. 'Nothing works' in secure residential youth care?

    NARCIS (Netherlands)

    Souverein, F.A.; van der Helm, G.H.P.; Stams, G.J.J.M.

    2013-01-01

    A debate about the effectiveness of secure residential youth care is currently going on. While some continue to support secure residential youth care, others conclude that ‘nothing works’ in secure residential youth care, and argue that non-residential treatment is superior to secure residential

  18. 76 FR 56339 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnaces and...

    Science.gov (United States)

    2011-09-13

    ...-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing... Refrigeration Institute (AHRI) recommended that to avoid unnecessary burden, the existing test procedure..., and Refrigeration Institute's Directory of Certified Product Performance for Residential Furnaces and...

  19. Re-thinking residential mobility

    Science.gov (United States)

    van Ham, Maarten; Findlay, Allan M.

    2015-01-01

    While researchers are increasingly re-conceptualizing international migration, far less attention has been devoted to re-thinking short-distance residential mobility and immobility. In this paper we harness the life course approach to propose a new conceptual framework for residential mobility research. We contend that residential mobility and immobility should be re-conceptualized as relational practices that link lives through time and space while connecting people to structural conditions. Re-thinking and re-assessing residential mobility by exploiting new developments in longitudinal analysis will allow geographers to understand, critique and address pressing societal challenges. PMID:27330243

  20. Large-Scale Residential Demolition

    Science.gov (United States)

    The EPA provides resources for handling residential demolitions or renovations. This includes planning, handling harmful materials, recycling, funding, compliance assistance, good practices and regulations.

  1. Emissions Characterization of Residential Wood-Fired Hydronic Heater Technologies

    Science.gov (United States)

    Residential wood-fired hydronic heaters (RWHHs) can negatively impact the local ambient air quality and thus are of major environmental concern in wood burning areas of the U. S. Few studies have been conducted which characterize the emissions from RWHHs. To address the lack of e...

  2. FUGACITY-BASED INDOOR RESIDENTIAL PESTICIDE FATE MODEL

    Science.gov (United States)

    Dermal and non-dietary pathways are possibly important for exposure to pesticides used in residences. Limited data have been collected on pesticide concentrations in residential air and surfaces following application. Models may be useful for interpreting these data and to make...

  3. RESIDENTIAL WOOD COMBUSTION TECHNOLOGY REVIEW VOLUME 1. TECHNICAL REPORT

    Science.gov (United States)

    This report gives results of a review of the current state-of-the-art of residential wood combustion (RWC). The key environmental parameter of concern was the air emission of particles. The technological status of all major RWC categories -- cordwood stoves, fireplaces, masonry h...

  4. RESIDENTIAL WOOD COMBUSTION TECHNOLOGY REVIEW - VOLUME 2. APPENDICES

    Science.gov (United States)

    The report gives results of a review of the current state-of-the-art of residential wood combustion (RWC). The key environmental parameter of concern was the air emission of particles. The technological status of all major RWC categories--cordwood stoves, fireplaces, masonry heat...

  5. Sorption of organic gases in residential rooms

    Science.gov (United States)

    Singer, Brett C.; Hodgson, Alfred T.; Hotchi, Toshifumi; Ming, Katherine Y.; Sextro, Richard G.; Wood, Emily E.; Brown, Nancy J.

    Experiments were conducted to characterize organic gas sorption in residential rooms studied "as-is" with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink-diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms.

  6. Residential firewood use in the United States.

    Science.gov (United States)

    Lipfert, F W; Dungan, J L

    1983-03-25

    An empirical relation between residential firewood use and population density was developed from survey data for 64 counties in New England and was corroborated by data from other states. The results indicate that usage is concentrated in urbanized areas of the Northeast and north central states and that about 9.0 to 11.0 percent of U.S. space heating input is from firewood. No constraints due to the supply of wood were apparent in 1978-1979. These findings have implications for effects on air quality.

  7. Toxic air pollutants notice of construction for rotary mode core sampling systems three and four and modification system two

    International Nuclear Information System (INIS)

    Dyekman, D.L.

    1998-01-01

    The Washington State Department of Ecology (Ecology) approved the construction and operation of Rotary Mode Core Sampling (RMCS) System Two on November 22, 1993 (NOC-93-04). This approval supported the characterization of waste in the single-shell tanks (SSTS) and double-shell tanks (DSTS) on the Hanford Site. The waste tank characterization sampling and analysis effort is vital to the safe operations of the Hanford Site tank farms, and the timely collection of the information necessary to support retrieval, pretreatment, disposal planning, and final closure strategy. This is based on the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 93-05 Implementation Plan (DOE-RL-94-001), US Department of Energy, Richland Operations Office (DOE-RL) proposed the expedited construction and operation of two additional RMCS systems to support characterization of waste stored in SSTs and DSTS. RMCS currently is scheduled for approximately 50 (active or passively ventilated) of the 149 SSTs in the 200 East and 200 West Areas. If necessary, the RMCS will be used to sample other tanks currently not scheduled, subject to the requirements of this document and any applicable Ecology approval order. The typical components of the RMCS systems are shown in Figure 1. It should be noted that the Flammable Gas Detector cart is not being used during RMCS at this time. RMCS is scheduled for approximately 40 tanks that are not actively ventilated. These tanks operate at atmospheric pressure with passive (breather) high-efficiency particulate air (HEPA) filters. The RMCS system uses nitrogen gas to cool and purge the drill bit assembly. Without the use of a portable ventilation system, the additional gas from RMCS might unsafely pressurize tanks that are not actively ventilated. The RMCS system also will generate aerosols and dust in the tank vapor head space. HEPA filters will be required on the portable exhauster during rotary mode core drilling to control radionuclide

  8. Methods for regionalization of impacts of non-toxic air pollutants in life-cycle assessments often tell a consistent story

    Science.gov (United States)

    Djomo, S. Njakou; Knudsen, M. T.; Andersen, M. S.; Hermansen, J. E.

    2017-11-01

    There is an ongoing debate regarding the influence of the source location of pollution on the fate of pollutants and their subsequent impacts. Several methods have been developed to derive site-dependent characterization factors (CFs) for use in life-cycle assessment (LCA). Consistent, precise, and accurate estimates of CFs are crucial for establishing long-term, sustainable air pollution abatement policies. We reviewed currently available studies on the regionalization of non-toxic air pollutants in LCA. We also extracted and converted data into indices for analysis. We showed that CFs can distinguish between emissions occurring in different locations, and that the different methods used to derive CFs map locations consistently from very sensitive to less sensitive. Seasonal variations are less important for the computation of CFs for acidification and eutrophication, but they are relevant for the calculation of CFs for tropospheric ozone formation. Large intra-country differences in estimated CFs suggest that an abatement policy relying on quantitative estimates based upon a single method may have undesirable outcomes. Within country differences in estimates of CFs for acidification and eutrophication are the results of the models used, category definitions, soil sensitivity factors, background emission concentration, critical loads database, and input data. Striking features in these studies were the lack of CFs for countries outside Europe, the USA, Japan, and Canada, the lack of quantification of uncertainties. Parameter and input data uncertainties are well quantified, but the uncertainty associated with the choice of category indicator is rarely quantified and this can be significant. Although CFs are scientifically robust, further refinements are needed before they can be integrated in LCA. Future research should include uncertainty analyses, and should develop a consensus model for CFs. CFs for countries outside Europe, Japan, Canada and the USA are

  9. Solar ejector refrigerant system in China’s residential buildings

    Directory of Open Access Journals (Sweden)

    Zheng Hui-Fan

    2014-01-01

    Full Text Available A simulation program describing the performance of solar ejector refrigerant system for air conditioning of China’s residential buildings was established. Hourly performance of the system under different operate conditions, the collector efficiency, coefficient of performance, cooling capacity and cooling load were analyzed. It is found that the collector efficiency and the overall coefficient of performance increase first and then decline, and it can be concluded that the application of solar ejector refrigerant system will have a better developmental prospect in China’s residential buildings.

  10. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  11. College residential sleep environment.

    Science.gov (United States)

    Sexton-Radek, Kathy; Hartley, Andrew

    2013-12-01

    College students regularly report increased sleep disturbances as well as concomitant reductions in performance (e.g., academic grades) upon entering college. Sleep hygiene refers to healthy sleep practices that are commonly used as first interventions in sleep disturbances. One widely used practice of this sort involves arranging the sleep environment to minimize disturbances from excessive noise and light at bedtime. Communal sleep situations such as those in college residence halls do not easily support this intervention. Following several focus groups, a questionnaire was designed to gather self-reported information on sleep disturbances in a college population. The present study used The Young Adult Sleep Environment Inventory (YASEI) and sleep logs to investigate the sleep environment of college students living in residential halls. A summary of responses indicated that noise and light are significant sleep disturbances in these environments. Recommendations are presented related to these findings.

  12. Envelope Thermal Design Optimization for Urban Residential Buildings in Malawi

    Directory of Open Access Journals (Sweden)

    Amos Kalua

    2016-04-01

    Full Text Available This study sought to optimize the envelope thermal design of free-running urban residential buildings in Malawi. It specifically set out to improve the urban residential buildings’ thermal comfort and suggest optimal envelope thermal design features for these buildings. The research study was primarily dependent on computer simulations in EnergyPlus to replicate the typical Malawian urban residential building’s thermal behaviour and then study the impacts of various envelope configurations on the thermal comfort conditions registered in the building. The simulation model was experimentally validated to check its appropriateness to the climatic design conditions prevalent in Malawi and out of the three major cities that were considered, the model was found to be appropriate for use in the two cities of Mzuzu and Lilongwe leaving out the city of Blantyre. The optimization methodology that was employed involved the use of orthogonal arrays, statistical analyses and the listing method. It was found that the optimal envelope thermal design, which registered up to 18% lower discomfort hours than that of the typical urban residential building, consists of a 50 mm concrete floor slab, 230 mm burnt brick walls with an external layer of 19 mm EPS, tiled roof with an internal layer of sarking and 50 mm EPS, double Low-E Glazing with a transparency ratio of 45% and 0.2408 m2 of adaptable operational surface area for the air bricks. Out of all the envelope features that were studied, air infiltration registered the most significant contribution towards the ultimate residential building thermal performance. It was demonstrated that controlled air infiltration through the use of operable air bricks whose operational surface area is adaptable can be very effective in enhancing the building’s comfort levels. It was further observed that excessive insulation of the building envelope generally has a detrimental effect on the indoor space thermal comfort

  13. Impact of emissions from natural gas production facilities on ambient air quality in the Barnett Shale area: a pilot study.

    Science.gov (United States)

    Zielinska, Barbara; Campbell, Dave; Samburova, Vera

    2014-12-01

    Rapid and extensive development of shale gas resources in the Barnett Shale region of Texas in recent years has created concerns about potential environmental impacts on water and air quality. The purpose of this study was to provide a better understanding of the potential contributions of emissions from gas production operations to population exposure to air toxics in the Barnett Shale region. This goal was approached using a combination of chemical characterization of the volatile organic compound (VOC) emissions from active wells, saturation monitoring for gaseous and particulate pollutants in a residential community located near active gas/oil extraction and processing facilities, source apportionment of VOCs measured in the community using the Chemical Mass Balance (CMB) receptor model, and direct measurements of the pollutant gradient downwind of a gas well with high VOC emissions. Overall, the study results indicate that air quality impacts due to individual gas wells and compressor stations are not likely to be discernible beyond a distance of approximately 100 m in the downwind direction. However, source apportionment results indicate a significant contribution to regional VOCs from gas production sources, particularly for lower-molecular-weight alkanes (air toxics combined with soot to total carbon ratios that were high for an area with little residential or commercial development may be indicative of the impact of increased heavy-duty vehicle traffic related to gas production. Implications: Rapid and extensive development of shale gas resources in recent years has created concerns about potential environmental impacts on water and air quality. This study focused on directly measuring the ambient air pollutant levels occurring at residential properties located near natural gas extraction and processing facilities, and estimating the relative contributions from gas production and motor vehicle emissions to ambient VOC concentrations. Although only a small

  14. Ozone Reductions Using Residential Building Envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Sherman, Max; Nazaroff, William W.

    2009-02-01

    Ozone is an air pollutant with that can have significant health effects and a significant source of ozone in some regions of California is outdoor air. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone could lead to improved health for many California residents. Ozone is removed from indoor air by surface reactions and can also be filtered by building envelopes. The magnitude of the envelope impact depends on the specific building materials that the air flows over and the geometry of the air flow paths through the envelope that can be changes by mechanical ventilation operation. The 2008 Residential Building Standards in California include minimum requirements for mechanical ventilation by referencing ASHRAE Standard 62.2. This study examines the changes in indoor ozone depending on the mechanical ventilation system selected to meet these requirements. This study used detailed simulations of ventilation in a house to examine the impacts of different ventilation systems on indoor ozone concentrations. The simulation results showed that staying indoors reduces exposure to ozone by 80percent to 90percent, that exhaust ventilation systems lead to lower indoor ozone concentrations, that opening of windows should be avoided at times of high outdoor ozone, and that changing the time at which mechanical ventilation occurs has the ability to halve exposure to ozone. Future work should focus on the products of ozone reactions in the building envelope and the fate of these products with respect to indoor exposures.

  15. Residential radon and lung cancer incidence in a Danish cohort

    DEFF Research Database (Denmark)

    Bräuner, Elvira Vaclavik; Andersen, Claus Erik; Sørensen, Mette

    2012-01-01

    High-level occupational radon exposure is an established risk factor for lung cancer. We assessed the long-term association between residential radon and lung cancer risk using a prospective Danish cohort using 57,053 persons recruited during 1993–1997. We followed each cohort member for cancer...... occurrence until 27 June 2006, identifying 589 lung cancer cases. We traced residential addresses from 1 January 1971 until 27 June 2006 and calculated radon at each of these addresses using information from central databases regarding geology and house construction. Cox proportional hazards models were used...... to estimate incidence rate ratios (IRR) and 95% confidence intervals (CI) for lung cancer risk associated with residential radon exposure with and without adjustment for sex, smoking variables, education, socio-economic status, occupation, body mass index, air pollution and consumption of fruit and alcohol...

  16. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples

    International Nuclear Information System (INIS)

    Rajabi, Maryam; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-01-01

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2–70, 6–360, 7–725, 7–370, and 8–450 ng mL −1 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ and Ni 2+ ions, respectively, with the correlation of determinations (R 2 s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid and tap water samples. - Highlights: • A novel centrifugeless dispersive

  17. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples

    Energy Technology Data Exchange (ETDEWEB)

    Rajabi, Maryam, E-mail: mrajabi@semnan.ac.ir; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-03-08

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}, and Ni{sup 2+} prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2–70, 6–360, 7–725, 7–370, and 8–450 ng mL{sup −1} for the Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}and Ni{sup 2+} ions, respectively, with the correlation of determinations (R{sup 2}s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}, and Ni{sup 2+} ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid

  18. Estimating air emissions from a remediation of a petroleum sump using direct measurement and modeling

    International Nuclear Information System (INIS)

    Schmidt, C.E.

    1991-01-01

    A technical approach was developed for the remediation of a petroleum sump near a residential neighborhood. The approach evolved around sludge handling/in-situ solidification and on-site disposal. As part of the development of the engineering approach, a field investigation and modeling program was conducted to predict air emissions from the proposed remediation. Field measurements using the EPA recommended surface isolation flux chamber were conducted to represent each major activity or air exposure involving waste at the site. Air emissions from freshly disturbed petroleum waste, along with engineering estimates were used to predict emissions from each phase of the engineering approach. This paper presents the remedial approach and the measurement/modeling technologies used to predict air toxic emissions from the remediation. Emphasis will be placed on the measurement approaches used in obtaining the emission rate data and the assumptions used in the modeling to estimate emissions from engineering scenarios

  19. Emission of PCDD/F, PCB, and HCB from combustion of firewood and pellets in residential stoves and boilers.

    Science.gov (United States)

    Hedman, Björn; Naslund, Morgan; Marklund, Stellan

    2006-08-15

    To assess potential emissions of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), and hexachlorobenzene (HCB) from residential combustion of biofuels, experiments were performed in which various types of pellets and firewood were combusted in four types of stoves and boilers, with both full and reduced rates of air supply. Intermittent combustion of wood pellets resulted in emissions of 11 ng-(WHO-TEQ)/kg combusted fuel (dry weight). A modern, environmentally certified boiler yielded somewhat lower emissions of PCCD/F and PCB than a wood stove. Both gave <0.1 ng(WHO-TEQ)/m3n (1.3-6.5 ng(WHO-TEQ)/kg) and considerably lower emissions than an old boiler (7.0-13 ng(WHO-TEQ)/kg). No positive effect on emissions could be observed in full air combustion (simulating the use of a heat storage tank) compared to combustion with reduced air. Two of the wood combustion experiments included paper and plastic waste fuels. Chlorine-containing plastic waste gave rise to high emissions: ca. 310 ng(WHO-TEQ)/ kg over the whole combustion cycle. The homologue profiles of PCDD/Fs show characteristic differences between ashes and flue gas from combustions with different levels of air supply. These differences do not, however, seem to have any correlation to the relative amount of toxic congeners.

  20. Residential energy usage comparison: Findings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, B.A.; Uhlaner, R.T.; Cason, T.N.; Courteau, S. (Quantum Consulting, Inc., Berkeley, CA (United States))

    1991-08-01

    This report presents the research methods and results from the Residential Energy Usage Comparison (REUC) project, a joint effort by Southern California Edison Company (SCE) and the Electric Power Research Institute (EPRI). The REUC project design activities began in early 1986. The REUC project is an innovative demand-site project designed to measure and compare typical energy consumption patterns of energy efficient residential electric and gas appliances. 95 figs., 33 tabs.

  1. The impact of residential combustion emissions on atmospheric aerosol, human health and climate

    Science.gov (United States)

    Butt, E. W.; Rap, A.; Schmidt, A.; Reddington, C.; Scott, C.; Pringle, K.; Woodhouse, M.; Spracklen, D. V.

    2015-12-01

    Combustion of fuels in the residential sector for cooking and heating, results in the emission of aerosol and aerosol precursors that effect air quality, human health and climate. Residential emissions are dominated by the combustion of solid fuels which are the primary energy source for nearly half the world's population. Despite this importance, residential emissions are poorly quantified, as are their impacts on air quality and climate. We used a global aerosol microphysics model to simulate the impact of residential emissions on atmospheric aerosol in the year 2000, and evaluated simulated concentrations against surface observations of aerosol mass and number. Residential emissions make the largest contributions to surface particulate matter (PM2.5) concentrations in East Asia, South Asia and Eastern Europe, matching regions of greatest emissions. We used concentration response functions to estimate a global annual excess adult (> 30 years of age) premature mortality due to residential emissions of between 113, 300 and 827, 000 when uncertainties in both residential emissions and health effects of PM2.5 were accounted for. Premature mortality was greatest in Asia, with China and India accounting for 50% of simulated global excess mortality. Using an offline radiative transfer model, we show that residential emissions exerted a global annual mean direct radiative effect of between -66 mW m-2 and +21 mW m-2, accounting for uncertainties in emissions flux and assumed ratio of carbonaceous and sulphur emissions. Residential emissions exerted a negative global annual mean first aerosol indirect effect of between -52 mW m-2 and -16 mW m-2, which was found to be sensitive to the assumed size distribution of carbonaceous emissions. Our results demonstrate that reducing residential combustion emissions would have substantial benefits for human health through reductions in ambient PM2.5 concentrations.

  2. Residential traffic exposure and pregnancy-related outcomes: A prospective birth cohort study

    NARCIS (Netherlands)

    Hooven, E.H. van den; Jaddoe, V.W.; Kluizenaar, Y. de; Hofman, A.; MacKenbach, J.P.; Steegers, E.A.; Miedema, H.M.; Pierik, F.H.

    2009-01-01

    Background. The effects of ambient air pollution on pregnancy outcomes are under debate. Previous studies have used different air pollution exposure assessment methods. The considerable traffic-related intra-urban spatial variation needs to be considered in exposure assessment. Residential proximity

  3. Maximizing Information from Residential Measurements of Volatile Organic Compounds

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Li, Na [Berkeley Analytical Associates, Richmond, CA (United States); Hodgson, Alfred [Berkeley Analytical Associates, Richmond, CA (United States); Offermann, Francis [Indoor Environmental Engineering, San Francisco, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-02-01

    Continually changing materials used in home construction and finishing can introduce new chemicals or changes in the VOC profile in residential air and the trend towards tighter homes can lead to higher exposure concentrations for many indoor sources. However, the complex mixture of VOCs in residential air makes it difficult to discover emerging contaminants and/or trends in pollutant profiles. The purpose of this study is to prepare a comprehensive library of chemicals found in homes, along with a semi-quantitative approach to maximize the information gained from VOC measurements. We carefully reviewed data from 108 new California homes and identified 238 individual compounds. The majority of the identified VOCs originated indoors. Only 31% were found to have relevant health based exposure guidelines and less than 10% had a chronic reference exposure level (CREL). The finding highlights the importance of extending IAQ studies to include a wider range of VOCs

  4. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  5. Practical Diagnostics for Evaluating Residential Commissioning Metrics

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig; Walker, Iain; Siegel, Jeff; Sherman, Max

    2002-06-11

    In this report, we identify and describe 24 practical diagnostics that are ready now to evaluate residential commissioning metrics, and that we expect to include in the commissioning guide. Our discussion in the main body of this report is limited to existing diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. Appendix C describes the 83 other diagnostics that we have examined in the course of this project, but that are not ready or are inappropriate for residential commissioning. Combined with Appendix B, Table 1 in the main body of the report summarizes the advantages and disadvantages of all 107 diagnostics. We first describe what residential commissioning is, its characteristic elements, and how one might structure its process. Our intent in this discussion is to formulate and clarify these issues, but is largely preliminary because such a practice does not yet exist. Subsequent sections of the report describe metrics one can use in residential commissioning, along with the consolidated set of 24 practical diagnostics that the building industry can use now to evaluate them. Where possible, we also discuss the accuracy and usability of diagnostics, based on recent laboratory work and field studies by LBNL staff and others in more than 100 houses. These studies concentrate on evaluating diagnostics in the following four areas: the DeltaQ duct leakage test, air-handler airflow tests, supply and return grille airflow tests, and refrigerant charge tests. Appendix A describes those efforts in detail. In addition, where possible, we identify the costs to purchase diagnostic equipment and the amount of time required to conduct the diagnostics. Table 1 summarizes these data. Individual equipment costs for the 24

  6. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emission from the M882 9-MM Ball Cartridge. Department of Defense Identification Code: A363

    National Research Council Canada - National Science Library

    Mobley, Joleen

    2001-01-01

    .... This document presents the evaluation of the potential for adverse human health effects to the offsite resident breathing air emissions following the use of military firing ranges during training exercises...

  7. Training Munitions Health Risk Assessment NO. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M1911.45 Caliber Ball Cartridge Department of Defense Identification Code: A475

    National Research Council Canada - National Science Library

    Coakley, Stafford

    2001-01-01

    ... .45 Caliber Ball Cartridge. This document presents the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  8. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M200 5.56-MM Blank Cartridge. Department of Defense Identification Code: A080

    National Research Council Canada - National Science Library

    Mobley, Joleen

    2001-01-01

    ... of the 5.56mm Blank Cartridge. This document presents the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  9. Training Munitions Health Risk Assessment NO. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M862 5.56-MM Practice Cartridge Department of Defense Indentification Code: A065

    National Research Council Canada - National Science Library

    Chang, Hsieng-Ye

    2001-01-01

    ... of the 5.56mm Practice Cartridge. This document present the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  10. Training Munitions Health Risk Assessment NO. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the 155-MM Propelling Charge (M3 Series) Department of Defense Identification Code: D540

    National Research Council Canada - National Science Library

    Chang, Hsieng-Ye

    2001-01-01

    ... of the potential for adverse human health effects to the off site residents breathing air emissions following the use of military firing ranges during training exercises - Study results showed no potential...

  11. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M1A1.50 Caliber Blank Cartridge Department of Defense Identification Code: A559

    National Research Council Canada - National Science Library

    2001-01-01

    ... .50 Caliber Blank Cartridge. This document presents the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  12. Training Munitions Health Risk Assessment No. 39-EJ-1485-00 Residential Exposure from Inhalation of Air Emissions from the M855 5.56-MM Tungsten Ball Cartridge

    National Research Council Canada - National Science Library

    Mobley, Joleen

    2001-01-01

    ... of the 5.56mm Tungsten Ball Cartridge. This document present the evaluation of the potential for adverse human health effects to the offsite residents breathing air emissions following the use of military firing ranges during training exercises...

  13. Community Multiscale Air Quality Modeling System (CMAQ)

    Science.gov (United States)

    CMAQ is a computational tool used for air quality management. It models air pollutants including ozone, particulate matter and other air toxics to help determine optimum air quality management scenarios.

  14. Computer program for sizing residential energy recovery ventilator

    International Nuclear Information System (INIS)

    Koontz, M.D.; Lee, S.M.; Spears, J.W.; Kesselring, J.P.

    1991-01-01

    Energy recovery ventilators offer the prospect of tighter control over residential ventilation rates than manual methods, such as opening windows, with a lesser energy penalty. However, the appropriate size of such a ventilator is not readily apparent in most situations. Sizing of energy recovery ventilation software was developed to calculate the size of ventilator necessary to satisfy ASHRAE Standard 62-1989, Ventilation for Acceptable Air Quality, or a user-specified air exchange rate. Inputs to the software include house location, structural characteristics, house operations and energy costs, ventilation characteristics, and HVAC system COP/efficiency. Based on these inputs, the program estimates the existing air exchange rate for the house, the ventilation rate required to meet the ASHRAE standard or user-specified air exchange rate, the size of the ventilator needed to meet the requirement, and the expected changes in indoor air quality and energy consumption. In this paper an illustrative application of the software is provided

  15. Prediction of residential building energy consumption: A neural network approach

    International Nuclear Information System (INIS)

    Biswas, M.A. Rafe; Robinson, Melvin D.; Fumo, Nelson

    2016-01-01

    Some of the challenges to predict energy utilization has gained recognition in the residential sector due to the significant energy consumption in recent decades. However, the modeling of residential building energy consumption is still underdeveloped for optimal and robust solutions while this research area has become of greater relevance with significant advances in computation and simulation. Such advances include the advent of artificial intelligence research in statistical model development. Artificial neural network has emerged as a key method to address the issue of nonlinearity of building energy data and the robust calculation of large and dynamic data. The development and validation of such models on one of the TxAIRE Research houses has been demonstrated in this paper. The TxAIRE houses have been designed to serve as realistic test facilities for demonstrating new technologies. The input variables used from the house data include number of days, outdoor temperature and solar radiation while the output variables are house and heat pump energy consumption. The models based on Levenberg-Marquardt and OWO-Newton algorithms had promising results of coefficients of determination within 0.87–0.91, which is comparable to prior literature. Further work will be explored to develop a robust model for residential building application. - Highlights: • A TxAIRE research house energy consumption data was collected in model development. • Neural network models developed using Levenberg–Marquardt or OWO-Newton algorithms. • Model results match well with data and statistically consistent with literature.

  16. Microclimate Patterns of Residential Landscapes Across the US

    Science.gov (United States)

    Learned, J.; Hall, S. J.

    2014-12-01

    Urban development has altered the physical and biological properties of native ecosystems worldwide. Research on the environmental outcomes of development continues to increase in scope. Climate phenomena, such as the Urban Heat Island (UHI) and Park Cool Island (PCI), are frequently used to illustrate how cities and managed landscapes differ from rural lands. The UHI describes the disparity between urban and rural temperatures, and results from heat retention within the built environment. These effects may be locally mitigated by vegetation (PCI). While the UHI is a useful tool for examining cities on a large scale, the methods are often too coarse to describe what individuals experience. We wondered: What large-scale climate trends are detectable at microclimate levels? Are microclimate patterns within residential landscapes typical, or are they geographically variable? To investigate, we installed sensors to monitor the air temperature within yards (residential landscapes) and native landscapes of 6 US cities from unique climate zones; Los Angeles, Phoenix, Minneapolis, Baltimore, Miami, and Boston. We hypothesized that microclimate trends would be similar among cities, and that microclimate patterns would predominate over large-scale climate trends within residential landscapes, especially when atmospheric mixing is low. Air temperature data collected between Aug. 2012 and July 2014 reveal that residential landscapes experience significantly different temperatures than native landscapes (pre-sunrise). The differences drive cities toward similarity, despite the variability of climate zones. The 6 cities also experience similar patterns of diurnal temperature fluctuations. Daily temperature ranges in yards are significantly greater than in their corresponding native landscapes during cooler months (p microclimates in residential landscapes can create local heat sinks within the built environment that may alleviate UHI effects in some cities. Additionally

  17. PENURUNAN TOKSISITAS LEACHATE (AIR LINDI DARI TPAS PUTRI CEMPO MOJOSONGO SURAKARTA DENGAN PAC (POLY ALUMINUM CHLORIDE (Toxicity Reduction of Leachate from Putri Cempo Municipal Landfill (TPAS Mojosongo Surakarta with PAC (Poly Aluminium Chloride

    Directory of Open Access Journals (Sweden)

    Dwi Astuti

    2010-03-01

    Full Text Available ABSTRAK Tujuan penelitian ini adalah menetapkan persen penurunan toksisitas sesudah diperlakukan dengan PAC. Rancangan penelitian ini adalah eksperimen murni dengan pretest-posttest with control group design. Populasi dalam penelitian ini adalah air lindi yang berasal dari TPAS Putri Cempo Mair lindi sebanyak 250 liter yang diambil dari bagian outlet, cara pengambilan sampel dengan metode quota sampling. Hasil menunjukkan bahwa toksisitas air lindi terhadap ikan uji berdasarkan LC50 24-96 jam sebagai berikut: (1 tanpa perlakuan PAC: 25,06% (24 jam; 21,07% (48 jam; 17,49% (72 jam; dan 14,97% (96 jam. (2 Dengan perlakuan PAC: 89,44% (24 jam; 63,73% (48 jam; 49,99% (72 jam; dan 40,96% (96 jam. Sehingga persentase penurunan toksisitasnya adalah: 64,38% (24 jam, 42,66% (48 jam, 32,50% (72 jam, dan 25,99% (96 jam.    ABSTRACT The aims of the current study were to determine percentage of leachate toxicity reduction after treatment with PAC. The experimental design used was true experimental study with pretest-posttest with control group design. Population in this study was leachate from Putri Cempo Landfill (TPAS Putri Cempo Mojosongo Surakarta. The sample was 250 litres leachate obtained from the landfill outlet by quota sampling method. The results revealed the leachate toxicity based on LC50 24-96 hours were: (1 without PAC treatment: 25.06% (24 hours, 21.07% (48 hours, 17.49% (72 hours, and 14.97% (96 hours; (2 with PAC treatment: 89.44% (24 hours, 63.73% (48 hours, 49.99% (72 hours, and 40.96% (96 hours. Therefore, the toxicity reductions were: 64.38% (24 hours, 42.66% (48 hours, 32.50% (72 hours, and 25.99% (96 hours.

  18. Residential radon in Finland: sources, variation, modelling and dose comparisons

    International Nuclear Information System (INIS)

    Arvela, H.

    1995-09-01

    The study deals with sources of indoor radon in Finland, seasonal variations in radon concentration, the effect of house construction and ventilation and also with the radiation dose from indoor radon and terrestrial gamma radiation. The results are based on radon measurements in approximately 4000 dwellings and on air exchange measurements in 250 dwellings as well as on model calculations. The results confirm that convective soil air flow is by far the most important source of indoor radon in Finnish low-rise residential housing. (97 refs., 61 figs., 30 tabs.)

  19. Residential radon in Finland: sources, variation, modelling and dose comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H.

    1995-09-01

    The study deals with sources of indoor radon in Finland, seasonal variations in radon concentration, the effect of house construction and ventilation and also with the radiation dose from indoor radon and terrestrial gamma radiation. The results are based on radon measurements in approximately 4000 dwellings and on air exchange measurements in 250 dwellings as well as on model calculations. The results confirm that convective soil air flow is by far the most important source of indoor radon in Finnish low-rise residential housing. (97 refs., 61 figs., 30 tabs.).

  20. Toxic Synovitis

    Science.gov (United States)

    ... substances made by the body's immune system to fight the infection. Toxic synovitis can happen at any age, but is most common in kids between 3 and 8 years old. It's also more common in boys. Sometimes toxic ...

  1. Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Tomasi, Roberta

    in progress. An experimental laboratory study in a simulated residential room with a seated occupant simulated by a thermal manikin was performed in order to evaluate thermal comfort and ventilation effectiveness. Thermal comfort was evaluated by means of vertical air temperature and air velocity profiles...... for comfortable thermal environment recommended by the standards. The cooler supply air mixed well and the effect of the position of air terminal devices was small. When warm unconditioned outside air was supplied by mixing ventilation in combination with the radiant floor cooling, low floor temperature......Mixing air ventilation system is one of the main ventilation concepts applied in residential buildings. The effect of combining the mixing ventilation system with the radiant floor heating has been well established, whereas the validation of using the floor for cooling in summer is still...

  2. Volatile organic compounds in indoor air: A review ofconcentrations measured in North America since 1990

    Energy Technology Data Exchange (ETDEWEB)

    ATHodgson@lbl.gov

    2003-04-01

    Central tendency and upper limit concentrations of volatile organic compounds (VOCs) measured in indoor air are summarized and reviewed. Data were obtained from published cross-sectional studies of residential and office buildings conducted in North America from 1990through the present. VOC concentrations in existing residences reported in 12 studies comprise the majority of the data set. Central tendency and maximum concentrations are compared between new and existing residences and between existing residences and office buildings. Historical changes in indoor VOC concentrations since the Clean Air Act Amendments of 1990 are explored by comparing the current data set with two published reviews of previous data obtained primarily in the 1980s. These historical comparisons suggest average indoor concentrations of some toxic air contaminants, such as 1,1,1-trichloroethane have decreased.

  3. The impact of residential combustion emissions on atmospheric aerosol, human health, and climate

    Directory of Open Access Journals (Sweden)

    E. W. Butt

    2016-01-01

    Full Text Available Combustion of fuels in the residential sector for cooking and heating results in the emission of aerosol and aerosol precursors impacting air quality, human health, and climate. Residential emissions are dominated by the combustion of solid fuels. We use a global aerosol microphysics model to simulate the impact of residential fuel combustion on atmospheric aerosol for the year 2000. The model underestimates black carbon (BC and organic carbon (OC mass concentrations observed over Asia, Eastern Europe, and Africa, with better prediction when carbonaceous emissions from the residential sector are doubled. Observed seasonal variability of BC and OC concentrations are better simulated when residential emissions include a seasonal cycle. The largest contributions of residential emissions to annual surface mean particulate matter (PM2.5 concentrations are simulated for East Asia, South Asia, and Eastern Europe. We use a concentration response function to estimate the human health impact due to long-term exposure to ambient PM2.5 from residential emissions. We estimate global annual excess adult (>  30 years of age premature mortality (due to both cardiopulmonary disease and lung cancer to be 308 000 (113 300–497 000, 5th to 95th percentile uncertainty range for monthly varying residential emissions and 517 000 (192 000–827 000 when residential carbonaceous emissions are doubled. Mortality due to residential emissions is greatest in Asia, with China and India accounting for 50 % of simulated global excess mortality. Using an offline radiative transfer model we estimate that residential emissions exert a global annual mean direct radiative effect between −66 and +21 mW m−2, with sensitivity to the residential emission flux and the assumed ratio of BC, OC, and SO2 emissions. Residential emissions exert a global annual mean first aerosol indirect effect of between −52 and −16 mW m−2, which is sensitive to the

  4. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains a minimum of 70 citations and includes a subject term index and title list.)

  5. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  6. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  7. Trends of Sustainable Residential Architecture

    OpenAIRE

    Narvydas, A

    2014-01-01

    The article is based on Master’s research conducted during Scottish Housing Expo 2010. The aim of the research was to determine the prevailing trends in sustainable residential architecture. Each trend can be described by features detected during visual and technical observation of project data. Based on that architects may predict possible problems related to a specific trend.

  8. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  9. Congestion and residential moving behaviour

    DEFF Research Database (Denmark)

    Larsen, Morten Marott; Pilegaard, Ninette; Van Ommeren, Jos

    2008-01-01

    we study how congestion and residential moving behaviour are interrelated, using a two-region job search model. Workers choose between interregional commuting and residential moving, in order to live closer to their place of work. This choice affects the external costs of commuting, due to conges......we study how congestion and residential moving behaviour are interrelated, using a two-region job search model. Workers choose between interregional commuting and residential moving, in order to live closer to their place of work. This choice affects the external costs of commuting, due...... to congestion. We focus on the equilibrium in which some workers currently living in one region accept jobs in the other, with a fraction of them choosing to commute from their current residence to the new job in the other region and the remainder choosing to move to the region in which the new job is located....... The welfare-maximising road tax is derived, which is essentially the Pigouvian tax, given the absence of a tax on moving. Given the presence of moving taxes, which are substantial in Europe, the optimal road tax for commuters is the Pigouvian tax plus the amortised value of the moving tax, evaluated...

  10. Convergence of Residential Gateway Technology

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Balm, M.; Jong, C.M. de; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  11. Toxic Elements

    DEFF Research Database (Denmark)

    Hajeb, Parvaneh; Shakibazadeh, Shahram; Sloth, Jens Jørgen

    2016-01-01

    Food is considered the main source of toxic element (arsenic, cadmium, lead, and mercury) exposure to humans, and they can cause major public health effects. In this chapter, we discuss the most important sources for toxic element in food and the foodstuffs which are significant contributors...... to human exposure. The occurrence of each element in food classes from different regions is presented. Some of the current toxicological risk assessments on toxic elements, the human health effect of each toxic element, and their contents in the food legislations are presented. An overview of analytical...... techniques and challenges for determination of toxic elements in food is also given....

  12. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  13. Energy efficiency program through exchange of air conditioners in residential sector of Manaus city: a concrete experience; Programa de eficiencia energetica atraves da troca de condicionadores de ar no setor residencial de Manaus: uma experiencia concreta

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Fabricio Rodrigues; Goncalves, Ana Catarina Lima Chaves; Cartaxo, Elizabeth Ferreira; Gomes, Hugo Miguel Oliveira; Nascimento, Nilton Correa; Inui, Raul Eiji; Guedes, Ricardo Augusto de Morais; Benchaya, Roberto Tavares [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil)

    2004-07-01

    The present review attempts to evaluate the importance of efficient equipment diffusion in reducing energy consumption, based upon the Study-case of an air conditioned exchange program in Manaus city of Amazonas. In spite of the existence, in the actual market, of efficient technology, it has been, yet, badly diffused, mostly due to economical and informative laps. Therefore, once tried to demonstrate the potential benefits, in technical gains, of energy efficiency offered by efficient Air conditioned equipment, through a plan that favors the consumer's participation as an active contributor in the dissemination process of efficient technology, and a following program for efficiency evaluation, beside a tributary evaluation proposal, so that technology becomes accessible to the general population, attempting its benefices. In addition, the environmental benefits of that specific proposal are analyzed, trough the developed recycling program. (author)

  14. Human Thermal Comfort In Residential House Buildings Of Jimma Town Southwest Ethiopia.

    Directory of Open Access Journals (Sweden)

    Chali Yadeta

    2015-08-01

    Full Text Available Indoor human thermal comfort is an important factor in indoor air quality assessment. Thermal comfort affects human health work efficiency and overall wellbeing. Thermal discomfort in indoors lowers the emotional and physical health of the occupants. This paper targets to explore human thermal comfort in residential house buildings of Jimma town and state some possible mechanisms to improve the existing thermal discomfort in large number the houses. For the study 303 structured questionnaires were distributed to the residential houses in thirteen places of the town based on predetermined criteria. The study reveals that human thermal discomfort in residential houses Jimma town are mainly from poor architectural design and improper use of heat generating appliances in indoors. The uses architectural design that suites the present climatic conditions and use of materials that facilitates ventilations will enhance the realization of the required human thermal comfort in residential houses of the study area.

  15. Residential traffic exposure and pregnancy-related outcomes: a prospective birth cohort study

    Directory of Open Access Journals (Sweden)

    Hofman Albert

    2009-12-01

    Full Text Available Abstract Background The effects of ambient air pollution on pregnancy outcomes are under debate. Previous studies have used different air pollution exposure assessment methods. The considerable traffic-related intra-urban spatial variation needs to be considered in exposure assessment. Residential proximity to traffic is a proxy for traffic-related exposures that takes into account within-city contrasts. Methods We investigated the association between residential proximity to traffic and various birth and pregnancy outcomes in 7,339 pregnant women and their children participating in a population-based cohort study. Residential proximity to traffic was defined as 1 distance-weighted traffic density in a 150 meter radius, and 2 proximity to a major road. We estimated associations of these exposures with birth weight, and with the risks of preterm birth and small size for gestational age at birth. Additionally, we examined associations with pregnancy-induced hypertension, (preeclampsia, and gestational diabetes. Results There was considerable variation in distance-weighted traffic density. Almost fifteen percent of the participants lived within 50 m of a major road. Residential proximity to traffic was not associated with birth and pregnancy outcomes in the main analysis and in various sensitivity analyses. Conclusions Mothers exposed to residential traffic had no higher risk of adverse birth outcomes or pregnancy complications in this study. Future studies may be refined by taking both temporal and spatial variation in air pollution exposure into account.

  16. Evaluating the Long-Term Health and Economic Impacts of Central Residential Air Filtration for Reducing Premature Mortality Associated with Indoor Fine Particulate Matter (PM2.5 of Outdoor Origin

    Directory of Open Access Journals (Sweden)

    Dan Zhao

    2015-07-01

    Full Text Available Much of human exposure to fine particulate matter (PM2.5 of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002–2.5% and increase life expectancy by 0.02–1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location.

  17. High Performance Residential Housing Units at U.S. Coast Guard Base Kodiak: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.; Hickey, J.

    2013-10-01

    The United States Coast Guard (USCG) constructs residential housing throughout the country using a basic template that must meet the minimum Leadership in Energy and Environmental Design (LEED) Silver criteria or better for the units. In Kodiak, Alaska, USCG is procuring between 24 and 100 residential multi-family housing units. Priorities for the Kodiak project were to reduce overall energyconsumption by at least 20% over existing units, improve envelope construction, and evaluate space heating options. USCG is challenged with maintaining similar existing units that have complicated residential diesel boilers. Additionally, fuel and material costs are high in Kodiak. While USCG has worked to optimize the performance of the housing units with principles of improved buildingenvelope, the engineers realize there are still opportunities for improvement, especially within the heating, ventilation, and air conditioning (HVAC) system and different envelope measures. USCG staff also desires to balance higher upfront project costs for significantly reduced life-cycle costs of the residential units that have an expected lifetime of 50 or more years. To answer thesequestions, this analysis used the residential modeling tool BEoptE+ to examine potential energy- saving opportunities for the climate. The results suggest criteria for achieving optimized housing performance at the lowest cost. USCG will integrate the criteria into their procurement process. To achieve greater than 50% energy savings, USCG will need to specify full 2x 6 wood stud R-21 insulationwith two 2 inches of exterior foam, R-38 ceiling insulation or even wall insulation in the crawl space, and R-49 fiberglass batts in a the vented attic. The air barrier should be improved to ensure a tight envelope with minimal infiltration to the goal of 2.0 ACH50. With the implementation of an air source heat pump for space heating requirements, the combination of HVAC and envelope savings inthe residential unit can save

  18. Residential mobility and childhood leukemia.

    Science.gov (United States)

    Amoon, A T; Oksuzyan, S; Crespi, C M; Arah, O A; Cockburn, M; Vergara, X; Kheifets, L

    2018-07-01

    Studies of environmental exposures and childhood leukemia studies do not usually account for residential mobility. Yet, in addition to being a potential risk factor, mobility can induce selection bias, confounding, or measurement error in such studies. Using data collected for California Powerline Study (CAPS), we attempt to disentangle the effect of mobility. We analyzed data from a population-based case-control study of childhood leukemia using cases who were born in California and diagnosed between 1988 and 2008 and birth certificate controls. We used stratified logistic regression, case-only analysis, and propensity-score adjustments to assess predictors of residential mobility between birth and diagnosis, and account for potential confounding due to residential mobility. Children who moved tended to be older, lived in housing other than single-family homes, had younger mothers and fewer siblings, and were of lower socioeconomic status. Odds ratios for leukemia among non-movers living mobility, including dwelling type, increased odds ratios for leukemia to 2.61 (95% CI: 1.76-3.86) for living mobility of childhood leukemia cases varied by several sociodemographic characteristics, but not by the distance to the nearest power line or calculated magnetic fields. Mobility appears to be an unlikely explanation for the associations observed between power lines exposure and childhood leukemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. RESIDENTIAL MORTGAGE IN MODERN RUSSIA

    Directory of Open Access Journals (Sweden)

    Dementiev N. P.

    2015-03-01

    Full Text Available The article presents a comparative analysis of residential mortgages in Russia and the United States. The primary ways of mortgage refinancing are outlined. Predominance of the elements of two-level refinancing system of residential mortgage in Russia and the United States is shown. The activity of the Agency for Housing Mortgage Lending (AHML, the basic tool of the Russian government’s mortgage policy, is described in detail. In its objectives and functions the AHML is similar to the American mortgage agencies Ginnie Mae, Fannie Mae and Freddie Mac. Similarities were identified in the Russian and US residential mortgages in the pre-crisis period (high rates of mortgage growth, favourable economic conjuncture, low interest rates, large increase in house prices, speculative housing demand. During the mortgage crisis, the policies of the Russian and US governments and monetary authorities had also much in common (monetary policy easing, cheap central banks loans, extended facilities of mortgage refinancing on the part of state agencies, mortgage rescue scheme, social mortgage programs. But the scope of mortgage in Russia is enormously narrow as compared to the US mortgage. The most important reason for that - low incomes of the Russian population.

  20. Indoor air quality environmental information handbook: Building system characteristics

    International Nuclear Information System (INIS)

    1987-01-01

    This manual, the third in a series, focuses on residential building system characteristics and their effects on indoor air quality. The manual addresses: residential indoor air pollutants by source, indoor concentrations, health effects, source control and mitigation techniques, standards and guidelines; building system characteristics of air exchange, pollutant source strength, residence volume, site characteristics, structural design, construction, and operation, infiltration and ventilation system, building occupancy; and monitoring methods

  1. GridLAB-D Technical Support Document: Residential End-Use Module Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Zachary T.; Gowri, Krishnan; Katipamula, Srinivas

    2008-07-31

    1.0 Introduction The residential module implements the following end uses and characteristics to simulate the power demand in a single family home: • Water heater • Lights • Dishwasher • Range • Microwave • Refrigerator • Internal gains (plug loads) • House (heating/cooling loads) The house model considers the following four major heat gains/losses that contribute to the building heating/cooling load: 1. Conduction through exterior walls, roof and fenestration (based on envelope UA) 2. Air infiltration (based on specified air change rate) 3. Solar radiation (based on CLTD model and using tmy data) 4. Internal gains from lighting, people, equipment and other end use objects. The Equivalent Thermal Parameter (ETP) approach is used to model the residential loads and energy consumption. The following sections describe the modeling assumptions for each of the above end uses and the details of power demand calculations in the residential module.

  2. Residential care : Dutch and Italian residents of residential care facilities compared

    NARCIS (Netherlands)

    de Heer-Wunderink, Charlotte; Caro-Nienhuis, Annemarie D.; Sytema, Sjoerd; Wiersma, Durk

    2008-01-01

    Aims - Characteristics of patients living in residential care facilities and the availability of mental hospital- and residential beds in Italy and The Netherlands were compared to assess whether differences in the process of deinstitutionalisation have influenced the composition of their

  3. The contribution of outdoor air pollution sources to premature mortality on a global scale

    Science.gov (United States)

    Lelieveld, J.; Evans, J. S.; Fnais, M.; Giannadaki, D.; Pozzer, A.

    2015-09-01

    Assessment of the global burden of disease is based on epidemiological cohort studies that connect premature mortality to a wide range of causes, including the long-term health impacts of ozone and fine particulate matter with a diameter smaller than 2.5 micrometres (PM2.5). It has proved difficult to quantify premature mortality related to air pollution, notably in regions where air quality is not monitored, and also because the toxicity of particles from various sources may vary. Here we use a global atmospheric chemistry model to investigate the link between premature mortality and seven emission source categories in urban and rural environments. In accord with the global burden of disease for 2010 (ref. 5), we calculate that outdoor air pollution, mostly by PM2.5, leads to 3.3 (95 per cent confidence interval 1.61-4.81) million premature deaths per year worldwide, predominantly in Asia. We primarily assume that all particles are equally toxic, but also include a sensitivity study that accounts for differential toxicity. We find that emissions from residential energy use such as heating and cooking, prevalent in India and China, have the largest impact on premature mortality globally, being even more dominant if carbonaceous particles are assumed to be most toxic. Whereas in much of the USA and in a few other countries emissions from traffic and power generation are important, in eastern USA, Europe, Russia and East Asia agricultural emissions make the largest relative contribution to PM2.5, with the estimate of overall health impact depending on assumptions regarding particle toxicity. Model projections based on a business-as-usual emission scenario indicate that the contribution of outdoor air pollution to premature mortality could double by 2050.

  4. The contribution of outdoor air pollution sources to premature mortality on a global scale.

    Science.gov (United States)

    Lelieveld, J; Evans, J S; Fnais, M; Giannadaki, D; Pozzer, A

    2015-09-17

    Assessment of the global burden of disease is based on epidemiological cohort studies that connect premature mortality to a wide range of causes, including the long-term health impacts of ozone and fine particulate matter with a diameter smaller than 2.5 micrometres (PM2.5). It has proved difficult to quantify premature mortality related to air pollution, notably in regions where air quality is not monitored, and also because the toxicity of particles from various sources may vary. Here we use a global atmospheric chemistry model to investigate the link between premature mortality and seven emission source categories in urban and rural environments. In accord with the global burden of disease for 2010 (ref. 5), we calculate that outdoor air pollution, mostly by PM2.5, leads to 3.3 (95 per cent confidence interval 1.61-4.81) million premature deaths per year worldwide, predominantly in Asia. We primarily assume that all particles are equally toxic, but also include a sensitivity study that accounts for differential toxicity. We find that emissions from residential energy use such as heating and cooking, prevalent in India and China, have the largest impact on premature mortality globally, being even more dominant if carbonaceous particles are assumed to be most toxic. Whereas in much of the USA and in a few other countries emissions from traffic and power generation are important, in eastern USA, Europe, Russia and East Asia agricultural emissions make the largest relative contribution to PM2.5, with the estimate of overall health impact depending on assumptions regarding particle toxicity. Model projections based on a business-as-usual emission scenario indicate that the contribution of outdoor air pollution to premature mortality could double by 2050.

  5. Introducing Toxics

    Directory of Open Access Journals (Sweden)

    David C. Bellinger

    2013-04-01

    Full Text Available With this inaugural issue, Toxics begins its life as a peer-reviewed, open access journal focusing on all aspects of toxic chemicals. We are interested in publishing papers that present a wide range of perspectives on toxicants and naturally occurring toxins, including exposure, biomarkers, kinetics, biological effects, fate and transport, treatment, and remediation. Toxics differs from many other journals in the absence of a page or word limit on contributions, permitting authors to present their work in as much detail as they wish. Toxics will publish original research papers, conventional reviews, meta-analyses, short communications, theoretical papers, case reports, commentaries and policy perspectives, and book reviews (Book reviews will be solicited and should not be submitted without invitation. Toxins and toxicants concern individuals from a wide range of disciplines, and Toxics is interested in receiving papers that represent the full range of approaches applied to their study, including in vitro studies, studies that use experimental animal or non-animal models, studies of humans or other biological populations, and mathematical modeling. We are excited to get underway and look forward to working with authors in the scientific and medical communities and providing them with a novel venue for sharing their work. [...

  6. Assessing the potential of residential HVAC systems for demand-side management

    NARCIS (Netherlands)

    van der Klauw, Thijs; Hoogsteen, Gerwin; Gerards, Marco Egbertus Theodorus; Hurink, Johann L.; Feng, Xianyong; Hebner, Robert E.

    This paper investigates the potential of residential heating, ventilation and air conditioning systems to contribute to dynamic demand-side management. Thermal models for seven houses in Austin, Texas are developed with the goal of using them in a planning based demand-side management methodology.

  7. A Case Study in Market Transformation for Residential Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Building Technologies Office

    2017-09-01

    This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.

  8. Living near highways : The impact of existing and planned highway infrastructure on residential satisfaction

    NARCIS (Netherlands)

    Hamersma, Marije

    2017-01-01

    Living near highways often comes with nuisances (noise, air pollution, barrier effects), but may also bring accessibility gains. This doctoral research provides insight in the impact of existing and planned highway infrastructure on residential satisfaction. The insights are based on a questionnaire

  9. Investigate and Comparsion Self-Esteem and Happiness Among Residential and Non-Residential Old People

    Directory of Open Access Journals (Sweden)

    Zakieh Nasiri

    2012-07-01

    Full Text Available Objectives: The main aim of this study was to investigate and to compare elderly happiness and self-esteem among residential and non-residential. Methods & Materials: This research was designed as descriptive. Two groups were selected in convenience method. Member of residential elderly (416 elderly were chosen based on Morgan Table. Hundred-twenty elderly, 60 residential (30 men and 30 women and 60 non-residential (30 men and 30 women were chosen for study. Data used the three questionnaires, like Demographic questionnaires, Oxford Happiness Inventory and Self-esteem Scale’s Rozenberg. Data were gathered and analyzed with Pearson test, t-student test. Results: The results were indicated that a significant relationship between happiness and self-esteem, among residential and non- residential old people. The findings showed significant difference in happiness, self-esteem among residential and home participants in both groups (P<0.01. Conclusion: The results were showed that a significant relationship between social support and self-esteem, among residential and non-residential old people. Also, the results were indicated that significant difference between social support. In general, residential participants had lower social support and self-esteem than non-residential participants.

  10. Manufactured residential utility wall system (ResCore), overview

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, R. [Oak Ridge National Lab., TN (United States); Lundell, C.; Lau, T.M. [Auburn Univ., AL (United States)

    1997-05-01

    This paper provides an overview of the design and development of a manufactured residential utility wall system referred to as ResCore. ResCore is a self-contained, manufactured, residential utility wall that provides complete rough-in of utilities (power, gas, water, and phone) and other functions (exhaust, combustion make-up air, refrigerant lines, etc.) to serve the residential kitchen, bath, utility, and laundry rooms. Auburn University, Department of Industrial Design faculty and students, supported by a team of graduate student researchers and the project`s advisory team, developed the ResCore. The project was accomplished through a research subcontract from the US Department of Energy administered by the Oak Ridge National Laboratory. The ResCore wall system features a ``layered`` manufacturing technique that allows each major component group--structural, cold water, hot water, drain, gas, electric, etc.--to be built as a separate subassembly and easily brought together for final assembly. The two structural layers are reinforced with bridging that adds strength and also permits firm attachment of plumbing pipes and other systems to the wall frame.

  11. Residential proximity to gasoline service stations and preterm birth.

    Science.gov (United States)

    Huppé, Vicky; Kestens, Yan; Auger, Nathalie; Daniel, Mark; Smargiassi, Audrey

    2013-10-01

    Preterm birth (PTB) is a growing public health problem potentially associated with ambient air pollution. Gasoline service stations can emit atmospheric pollutants, including volatile organic compounds potentially implicated in PTB. The objective of this study was to evaluate the relationship between residential proximity to gasoline service stations and PTB. Singleton live births on the Island of Montreal from 1994 to 2006 were obtained (n=267,478). Gasoline service station locations, presence of heavy-traffic roads, and neighborhood socioeconomic status (SES) were determined using a geographic information system. Multivariable logistic regression was used to analyze the association between PTB and residential proximity to gasoline service stations (50, 100, 150, 200, 250, and 500 m), accounting for maternal covariates, neighborhood SES, and heavy-traffic roads. For all distance categories beyond 50 m, presence of service stations was associated with a greater odds of PTB. Associations were robust to adjustment for maternal covariates for distance categories of 150 and 200 m but were nullified when adjusting for neighborhood SES. In analyses accounting for the number of service stations, the likelihood of PTB within 250 m was statistically significant in unadjusted models. Associations were, however, nullified in models accounting for maternal covariates or neighborhood SES. Our results suggest that there is no clear association between residential proximity to gasoline service stations in Montreal and PTB. Given the correlation between proximity of gasoline service stations and SES, it is difficult to delineate the role of these factors in PTB.

  12. Assessment of reflective insulations for residential and commercial applications

    Energy Technology Data Exchange (ETDEWEB)

    Yarbrough, D.W.

    1983-10-01

    A survey of available products, uses, and thermal resistance data for thermal insulations that use combinations of air gaps and reflective surfaces to form thermal barriers is presented. Reflective products like pipe insulation or high thermal resistance evacuated panels that are used exclusively in industrial applications are not included. A one-dimensional steady-state calculation has been developed to provide a way of discussing the R-values of refelctive assemblies and their sensitivity to properties like surface emissivity or positioning of foil surfaces in a cavity. The products considered are used in residential or commercial applications.

  13. Chapter 17: Residential Behavior Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, James [Cadmus Group, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral social sciences to influence household energy use. Strategies may include providing households with real-time or delayed feedback about their energy use; supplying energy-efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5%.

  14. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  15. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Directory of Open Access Journals (Sweden)

    Savchenko Olena

    2017-12-01

    Full Text Available The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  16. Beryllium Toxicity

    Science.gov (United States)

    ... Favorites Del.icio.us Digg Facebook Google Bookmarks Yahoo MyWeb Beryllium Toxicity Patient Education Care Instruction Sheet ... Favorites Del.icio.us Digg Facebook Google Bookmarks Yahoo MyWeb Page last reviewed: May 23, 2008 Page ...

  17. PEM - fuel cell system for residential applications

    Energy Technology Data Exchange (ETDEWEB)

    Britz, P. [Viessmann Werke GmbH and Co KG, 35107 Allendorf (Germany); Zartenar, N.

    2004-12-01

    Viessmann is developing a PEM fuel cell system for residential applications. The uncharged PEM fuel cell system has a 2 kW electrical and 3 kW thermal power output. The Viessmann Fuel Processor is characterized by a steam-reformer/burner combination in which the burner supplies the required heat to the steam reformer unit and the burner exhaust gas is used to heat water. Natural gas is used as fuel, which is fed into the reforming reactor after passing an integrated desulphurisation unit. The low temperature (600 C) fuel processor is designed on the basis of steam reforming technology. For carbon monoxide removal, a single shift reactor and selective methanisation is used with noble metal catalysts on monoliths. In the shift reactor, carbon monoxide is converted into hydrogen by the water gas shift reaction. The low level of carbon monoxide at the outlet of the shift reactor is further reduced, to approximately 20 ppm, downstream in the methanisation reactor, to meet PEM fuel cell requirements. Since both catalysts work at the same temperature (240 C), there is no requirement for an additional heat exchanger in the fuel processor. Start up time is less than 30 min. In addition, Viessmann has developed a 2 kW class PEFC stack, without humidification. Reformate and dry air are fed straight to the stack. Due to the dry operation, water produced by the cell reaction rapidly diffuses through the electrolyte membrane. This was achieved by optimising the MEA, the gas flow pattern and the operating conditions. The cathode is operated by an air blower. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  18. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  19. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  20. Residential instability: a perspective on system imbalance.

    Science.gov (United States)

    Appleby, Lawrence; Desai, Prakash

    1987-10-01

    In an exploration of residential instability and recidivism in chronic mental patients, 215 psychiatric admissions were followed for a year after the initial episode. In addition to an unusually high incidence of residential mobility, a relationship between mobility and number of hospitalizations was evident, as were isolation, disruptive family situations, and homelessness. The needed response of the mental health system is discussed.

  1. Credit Scores, Race, and Residential Sorting

    Science.gov (United States)

    Nelson, Ashlyn Aiko

    2010-01-01

    Credit scores have a profound impact on home purchasing power and mortgage pricing, yet little is known about how credit scores influence households' residential location decisions. This study estimates the effects of credit scores on residential sorting behavior using a novel mortgage industry data set combining household demographic, credit, and…

  2. Does immigrant residential crowding reflect hidden homelessness?

    Directory of Open Access Journals (Sweden)

    Michael Haan

    2011-12-01

    the extent to which heightened levels of residential crowding might reflect “hidden homelessness.” I find mixed evidence to support this link, and, if anything, find some evidence to suggest that the link between residential crowding and hidden homelessness, if one exists, is strongest for the Canadian-born.

  3. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads

  4. Solar-powered hot-air system

    Science.gov (United States)

    1979-01-01

    Solar-powered air heater supplies part or all of space heating requirements of residential or commercial buildings and is interfaced with air to water heat exchanger to heat domestic hot water. System has potential application in drying agricultural products such as cotton, lumber, corn, grains, and peanuts.

  5. Impact of wood combustion on particle levels in a residential area in Denmark

    DEFF Research Database (Denmark)

    Glasius, Marianne; Ketzel, Matthias; Wåhlin, Peter

    2006-01-01

    The influence of residential wood-combustion on local air quality was studied during two periods in 2002 and 2003/04 in a small rural town with widespread use of wood combustion for heating. During one 6-week winter period, particle levels (PM2.5) in the residential area were about 4 μg m-3 higher...... and at a background site. Receptor modelling and source apportionment of the results confirmed that the most important sources to particles were long-range transport (both organic and inorganic compounds) and local heating (particularly organic compounds) in addition to regional traffic emissions. Local wood...

  6. Residential radon and lung cancer incidence in a Danish cohort

    International Nuclear Information System (INIS)

    Bräuner, Elvira V.; Andersen, Claus E.; Sørensen, Mette; Jovanovic Andersen, Zorana; Gravesen, Peter; Ulbak, Kaare; Hertel, Ole; Pedersen, Camilla; Overvad, Kim; Tjønneland, Anne; Raaschou-Nielsen, Ole

    2012-01-01

    High-level occupational radon exposure is an established risk factor for lung cancer. We assessed the long-term association between residential radon and lung cancer risk using a prospective Danish cohort using 57,053 persons recruited during 1993–1997. We followed each cohort member for cancer occurrence until 27 June 2006, identifying 589 lung cancer cases. We traced residential addresses from 1 January 1971 until 27 June 2006 and calculated radon at each of these addresses using information from central databases regarding geology and house construction. Cox proportional hazards models were used to estimate incidence rate ratios (IRR) and 95% confidence intervals (CI) for lung cancer risk associated with residential radon exposure with and without adjustment for sex, smoking variables, education, socio-economic status, occupation, body mass index, air pollution and consumption of fruit and alcohol. Potential effect modification by sex, traffic-related air pollution and environmental tobacco smoke was assessed. Median estimated radon was 35.8 Bq/m 3 . The adjusted IRR for lung cancer was 1.04 (95% CI: 0.69–1.56) in association with a 100 Bq/m 3 higher radon concentration and 1.67 (95% CI: 0.69–4.04) among non-smokers. We found no evidence of effect modification. We find a positive association between radon and lung cancer risk consistent with previous studies but the role of chance cannot be excluded as these associations were not statistically significant. Our results provide valuable information at the low-level radon dose range.

  7. Public participation GIS for improving wood burning emissions from residential heating and urban environmental management.

    Science.gov (United States)

    López-Aparicio, Susana; Vogt, Matthias; Schneider, Philipp; Kahila-Tani, Maarit; Broberg, Anna

    2017-04-15

    A crowdsourcing study supported by a public participation GIS tool was designed and carried out in two Norwegian regions. The aim was to improve the knowledge about emissions from wood burning for residential heating in urban areas based on the collection of citizens' localized insights. We focus on three main issues: 1) type of dwelling and residential heating source; 2) wood consumption and type of wood appliances; and 3) citizens' perception of the urban environment. Our study shows the importance of wood burning for residential heating, and of the resulted particle emissions, in Norwegian urban areas. Citizens' localized insights on environmental perception highlight the areas in the city that require particular attention as part of clean air strategies. Information about environmental perception is combined with existing environmental data showing certain correlation. The results support the urban environmental management based on co-benefit approaches, achieving several outcomes from a single policy measure. Measures to reduce urban air pollution will have a positive impact on the citizens' environmental perception, and therefore on their quality of life, in addition to reducing the negative consequences of air pollution on human health. The characterization of residential heating by fuelwood is still a challenging activity. Our study shows the potential of a crowdsourcing method as means for bottom-up approaches designed to increase our knowledge on human activities at urban scale that result on emissions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Systemic Approach for Health Risk Assessment of Ambient Air Concentrations of Benzene in Petrochemical Environments: Integration of Fuzzy Logic, Artificial Neural Network, and IRIS Toxicity Method.

    Science.gov (United States)

    Novin, Vahid; Givehchi, Saeed; Hoveidi, Hassan

    2016-09-01

    Reliable methods are crucial to cope with uncertainties in the risk analysis process. The aim of this study is to develop an integrated approach to assessing risks of benzene in the petrochemical plant that produces benzene. We offer an integrated system to contribute imprecise variables into the health risk calculation. The project was conducted in Asaluyeh, southern Iran during the years from 2013 to 2014. Integrated method includes fuzzy logic and artificial neural networks. Each technique had specific computational properties. Fuzzy logic was used for estimation of absorption rate. Artificial neural networks can decrease the noise of the data so applied for prediction of benzene concentration. First, the actual exposure was calculated then it combined with Integrated Risk Information System (IRIS) toxicity factors to assess real health risks. High correlation between the measured and predicted benzene concentration was achieved (R 2 = 0.941). As for variable distribution, the best estimation of risk in a population implied 33% of workers exposed less than 1×10 -5 and 67% inserted between 1.0×10 -5 to 9.8×10 -5 risk levels. The average estimated risk of exposure to benzene for entire work zones is equal to 2.4×10 -5 , ranging from 1.5×10 -6 to 6.9×10 -5 . The integrated model is highly flexible as well as the rules possibly will be changed according to the necessities of the user in a different circumstance. The measured exposures can be duplicated well through proposed model and realistic risk assessment data will be produced.

  9. Residential radon survey in Finland

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Castren, O.

    1993-02-01

    The study measured the indoor radon concentration in the dwellings of 3074 persons, selected randomly from the central population register of Finland. Alpha track detectors and two consecutive half year measuring periods were used. The national mean of indoor radon concentration for persons living in low-rise residential buildings as well as blocks of flats was 145 and 82 Bq/m 3 , respectively. The mean for the total population was 123 Bq/m 3 . Based on the decision of the Ministry of Social Affairs and Health in 1992, the indoor radon concentration should not exceed 400 Bq/m 3 in already existing houses, the target for new construction being less than 200 Bq/m 3 . According to the study, the percentage of the Finnish population living in houses with an indoor radon concentration exceeding 200, 400 and 800 Bq/m 3 was 12.3 %, 3.6 % and 1.0 %

  10. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples.

    Science.gov (United States)

    Rajabi, Maryam; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-03-08

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2-70, 6-360, 7-725, 7-370, and 8-450 ng mL -1 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ and Ni 2+ ions, respectively, with the correlation of determinations (R 2 s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid and tap water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ..., along with simple instructions on how to access all documents, including public comments, in the docket... information regarding the current practices of manufacturer-run and private testing facilities. The Department seeks to understand how interested parties have interpreted test procedures provisions that they believe...

  12. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  13. Comparisons of traffic-related ultrafine particle number concentrations measured in two urban areas by central, residential, and mobile monitoring

    Science.gov (United States)

    Simon, Matthew C.; Hudda, Neelakshi; Naumova, Elena N.; Levy, Jonathan I.; Brugge, Doug; Durant, John L.

    2017-11-01

    Traffic-related ultrafine particles (UFP; urban air. While studies have shown that UFP are toxic, epidemiological evidence of health effects, which is needed to inform risk assessment at the population scale, is limited due to challenges of accurately estimating UFP exposures. Epidemiologic studies often use empirical models to estimate UFP exposures; however, the monitoring strategies upon which the models are based have varied between studies. Our study compares particle number concentrations (PNC; a proxy for UFP) measured by three different monitoring approaches (central-site, short-term residential-site, and mobile on-road monitoring) in two study areas in metropolitan Boston (MA, USA). Our objectives were to quantify ambient PNC differences between the three monitoring platforms, compare the temporal patterns and the spatial heterogeneity of PNC between the monitoring platforms, and identify factors that affect correlations across the platforms. We collected >12,000 h of measurements at the central sites, 1000 h of measurements at each of 20 residential sites in the two study areas, and >120 h of mobile measurements over the course of ∼1 year in each study area. Our results show differences between the monitoring strategies: mean 1 min PNC on-roads were higher (64,000 and 32,000 particles/cm3 in Boston and Chelsea, respectively) compared to central-site measurements (23,000 and 19,000 particles/cm3) and both were higher than at residences (14,000 and 15,000 particles/cm3). Temporal correlations and spatial heterogeneity also differed between the platforms. Temporal correlations were generally highest between central and residential sites, and lowest between central-site and on-road measurements. We observed the greatest spatial heterogeneity across monitoring platforms during the morning rush hours (06:00-09:00) and the lowest during the overnight hours (18:00-06:00). Longer averaging times (days and hours vs. minutes) increased temporal correlations

  14. The Clean Air Act Amendments and California Air Quality Issues

    International Nuclear Information System (INIS)

    Mester, Z.C.

    1992-01-01

    This paper reports on the Clean Air Act Ammendments (CAAA) which were enacted in 1990 and represents the most significant federal effort in over a decade to improve air quality. The CAAA thoroughly overhauled the previous Clean Air Act of 1977 and focused on several issues of growing concern, including: ozone, air toxics, and acid rain. Provisions for attainment of National Ambient Air Quality Standards (NAAQS) are described in Title I of the CAAA

  15. Indoor Residential Chemical Exposures as Risk Factors for Asthmaand Allergy in Infants and Children: a Review

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.

    2006-03-01

    Most research into effects of residential indoor air exposures on asthma and allergies has focused on exposures to biologic allergens, moisture and mold, endotoxin, or combustion byproducts. This paper briefly reviews reported findings on associations of asthma or allergy in infants or children with risk factors related to indoor chemical emissions from residential materials or surface coatings. Associations, some strong (e.g., odds ratios up to 13), were reported. The most frequently identified risk factors were formaldehyde, aromatic organic compounds such as toluene and benzene, plastic materials and plasticizers, and recent painting. Exposures and consequent effects from indoor sources may be exacerbated by decreased ventilation. Identified risk factors may be proxies for correlated exposures. Findings suggest the frequent occurrence of important but preventable effects on asthma and allergy in infants and children worldwide from modern residential building materials and coatings.

  16. Impact of Uncoordinated Plug-in Electric Vehicle Charging on Residential Power Demand

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-22

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  17. Impact of uncoordinated plug-in electric vehicle charging on residential power demand

    Science.gov (United States)

    Muratori, Matteo

    2018-01-01

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  18. Recommendations for energy conservation standards for new residential buildings: Volume 2: Automated residential energy standard---user's guide--version 1. 1

    Energy Technology Data Exchange (ETDEWEB)

    Lortz, V.B.; Taylor, Z.T.

    1989-05-01

    This report documents the development and testing of a set of recommendations from the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE) Special Projects Committee No. 53, designed to provide the technical foundation for the Congressionally-mandated energy standard for new residential buildings. The recommendations were developed over a 25-month period by a multidisciplinary project team under the management of the DOE and its prime contractor, Pacific Northwest Laboratory (PNL).

  19. PERAN AIR DALAM PENYEBARAN PENYAKIT

    Directory of Open Access Journals (Sweden)

    Dwi Priyanto

    2012-10-01

    Full Text Available Air merupakan komponen penting dalam kehidupan, semua jenis makhluk hidup memerlukan air untuk kelangsungan hidupnya. Untuk kepentingan manusia, air tidak saja digunakan untuk minum, masak dan cuci, tetapi juga untuk keperluan agrikultur, industri, transportasi, perikanan dan pembuangan limbah cair domestik dan industri. Dalam bidang kesehatan, beberapa  jenis penyakit melibatkan media air dalam proses penyebarannya, baik secara langsung maupun tidak langsung. Penyebaran penyakit secara tidak langsung oleh air disebabkan oleh kandungan bahan kimia terlarut dalam badan air yang bersifat toxic bagi tubuh manusia. Adanya bahan-bahan ini dalam air disebabkan aktifitas industri, pertanian maupun limbah domestik rumah tangga yang dibuang dan mencemari air.

  20. Evaluation of Multi Residential House Renovation Efficiency

    Directory of Open Access Journals (Sweden)

    Daiva Rapcevičienė

    2011-03-01

    Full Text Available Analyzed multi residential house renovation investment projects efficiency evaluation methods: economic-social, and environmental, as well as key financial valuation methods: simple pay-back period, the energy cost savings, the net present value, internal rate of return. Building walls condition regenerative rate which is used to evaluate investments in energy-saving measures is also discussed. According to reconstruction investments of multi residential house, three government financing programs of multi residential house are evaluated and selected the most effective program by comparing financial valuation methods taking and without taking into account building walls condition regenerative rate. Article in Lithuanian

  1. 12 CFR 541.16 - Improved residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Improved residential real estate. 541.16... REGULATIONS AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.16 Improved residential real estate. The term improved residential real estate means residential real estate containing offsite or other improvements...

  2. 12 CFR 541.23 - Residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Residential real estate. 541.23 Section 541.23... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.23 Residential real estate. The terms residential real estate... home used in part for business); (c) Other real estate used for primarily residential purposes other...

  3. 5 CFR 1655.20 - Residential loans.

    Science.gov (United States)

    2010-01-01

    ...'s primary residence is his or her principal residence. A primary residence may include a house, a... residence. A residential loan will not be made for a lease-to-buy option, unless the option to buy is being...

  4. RACIAL RESIDENTIAL SEGREGATION AND ADVERSE BIRTH OUTCOMES

    Science.gov (United States)

    INTRODUCTION. The disparity between black and white women's adverse birth outcomes has been subject to much investigation, yet the factors underlying its persistence remain elusive, which has encouraged research on neighborhood-level influences, including racial residential segr...

  5. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  6. Modeling radon transport in multistory residential buildings

    International Nuclear Information System (INIS)

    Persily, A.K.

    1993-01-01

    Radon concentrations have been studied extensively in single-family residential buildings, but relatively little work has been done in large buildings, including multistory residential buildings. The phenomena of radon transport in multistory residential buildings is made more complicated by the multizone nature of the airflow system and the numerous interzone airflow paths that must be characterized in such a system. This paper presents the results of a computer simulation of airflow and radon transport in a twelve-story residential building. Interzone airflow rates and radon concentrations were predicted using the multizone airflow and contaminant dispersal program (CON-TAM88). Limited simulations were conducted to study the influence of two different radon source terms, indoor-outdoor temperature difference and exterior wall leakage values on radon transport and radon concentration distributions

  7. Human Toxicity

    DEFF Research Database (Denmark)

    Jolliet, Olivier; Fantke, Peter

    2015-01-01

    This chapter reviews the human toxicological impacts of chemicals and how to assess these impacts in life cycle impact assessment (LCIA), in order to identify key processes and pollutants. The complete cause-effect pathway – from emissions of toxic substances up to damages on human health...... and their coverage in LCIA methods. Section 4 provides an overview of the main LCIA methods available to address human toxicological impacts. Section 5 presents the range of variation of factor across chemicals, the main sources of uncertainty and good interpretation practice of results from human toxicity...... all chemicals and impact pathways characterizes the contribution of each factor to the total variation of 10–12 orders of magnitude in impacts per kg across all chemicals. This large variation between characterisation factors for different chemicals as well as the 3 orders of magnitude uncertainty...

  8. Gentrification and Residential Mobility in Philadelphia

    OpenAIRE

    Ding, Lei; Hwang, Jackelyn; Divringi, Eileen

    2016-01-01

    Gentrification has provoked considerable controversy surrounding its effects on residential displacement. Using a unique individual-level, longitudinal data set, this study examines mobility rates and residential destinations of residents in gentrifying neighborhoods during the recent housing boom and bust in Philadelphia for various strata of residents and different types of gentrification. We find that vulnerable residents, those with low credit scores and without mortgages, are generally n...

  9. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  10. Studying toxicity

    Science.gov (United States)

    Elkus, A.; LeBlanc, L.; Kim, C.; Van Beneden, R.; Mayer, G.

    2006-01-01

    With funding from the George Mitchell Center for the Environment at the University of Maine, a team of scientists used a simple laboratory-based sediment resuspension design, and two well-established aquatic toxicology models, fathead minnows (Pimephales promelas) and zebrafish (Danio rerio), to evaluate if resuspension of Penobscot river sediment significantly elevates the toxicity of river water and to provide preliminary information on the types of chemicals likely to desorb during resuspension. The group collected sediments from two sites with known chemical contamination downstream of the Great Works and Veazie dams. The sediments were examined to determine the dynamics of PAH desorption and degradation under different resuspension frequencies. The scientists used clarified water from resuspension experiments for toxicity tests with the water-flea Ceriodaphnia dubia, and other aquatic test organisms to infer toxicity from sediments from northern California rivers. Data from the study will help ascertain whether metals and/or xenoestrogens are present in the desorption water and give insight into possible avenues of sediment remediation.

  11. Particulate and gaseous emissions from residential biomass combustion

    International Nuclear Information System (INIS)

    Boman, Christoffer

    2005-04-01

    Biomass is considered to be a sustainable energy source with significant potentials for replacing electricity and fossil fuels, not at least in the residential sector. However, present wood combustion is a major source of ambient concentrations of hydrocarbons (e.g. VOC and PAH) and particulate matter (PM) and exposure to these pollutants have been associated with adverse health effects. Increased focus on combustion related particulate emissions has been seen concerning the formation, characteristics and implications to human health. Upgraded biomass fuels (e.g. pellets) provide possibilities of more controlled and optimized combustion with less emission of products of incomplete combustion (PICs). For air quality and health impact assessments, regulatory standards and evaluations concerning residential biomass combustion, there is still a need for detailed emission characterization and quantification when using different fuels and combustion techniques. This thesis summarizes the results from seven different papers. The overall objective was to carefully and systematically study the emissions from residential biomass combustion with respect to: i) experimental characterization and quantification, ii) influences of fuel, appliance and operational variables and iii) aspects of ash and trace element transformations and aerosol formation. Special concern in the work was on sampling, quantification and characterization of particulate emissions using different appliances, fuels and operating procedures. An initial review of health effects showed epidemiological evidence of potential adverse effect from wood smoke exposure. A robust whole flow dilution sampling set-up for residential biomass appliances was then designed, constructed and evaluated, and subsequently used in the following emission studies. Extensive quantifications and characterizations of particulate and gases emissions were performed for residential wood and pellet appliances. Emission factor ranges for

  12. Residential proximity to major roadways and traffic in relation to outcomes of in vitro fertilization.

    Science.gov (United States)

    Gaskins, Audrey J; Hart, Jaime E; Mínguez-Alarcón, Lidia; Chavarro, Jorge E; Laden, Francine; Coull, Brent A; Ford, Jennifer B; Souter, Irene; Hauser, Russ

    2018-03-29

    Emerging data from animal and human studies suggest that traffic-related air pollution adversely affects early pregnancy outcomes; however evidence is limited. We examined whether residential proximity to major roadways and traffic, as proxies for traffic-related air pollution, are associated with in vitro fertilization (IVF) outcomes. This analysis included 423 women enrolled in the Environment and Reproductive Health (EARTH) Study, a prospective cohort study, who underwent 726 IVF cycles (2004-2017). Using geocoded residential addresses collected at study entry, we calculated the distance to nearest major roadway and the traffic density within a 100 m radius. IVF outcomes were abstracted from electronic medical records. We used multivariable generalized linear mixed models to evaluate the associations between residential proximity to major roadways and traffic density and IVF outcomes adjusting for maternal age, body mass index, race, education level, smoking status, and census tract median income. Closer residential proximity to major roadways was statistically significantly associated with lower probability of implantation and live birth following IVF. The adjusted percentage of IVF cycles resulting in live birth for women living ≥400 m from a major roadway was 46% (95% CI 36, 56%) compared to 33% (95% CI 26, 40%) for women living proximity to major roadways was related to reduced likelihood of live birth following IVF. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Analysis Thermal Comfort Condition in Complex Residential Building, Case Study: Chiangmai, Thailand

    Science.gov (United States)

    Juangjandee, Warangkana

    2017-10-01

    Due to the increasing need for complex residential buildings, it appears that people migrate into the high-density urban areas because the infrastructural facilities can be easily found in the modern metropolitan areas. Such rapid growth of urbanization creates congested residential buildings obstructing solar radiation and wind flow, whereas most urban residents spend 80-90% of their time indoor. Furthermore, the buildings were mostly built with average materials and construction detail. This causes high humidity condition for tenants that could promote mould growth. This study aims to analyse thermal comfort condition in complex residential building, Thailand for finding the passive solution to improve indoor air quality and respond to local conditions. The research methodology will be in two folds: 1) surveying on case study 2) analysis for finding the passive solution of reducing humidity indoor air The result of the survey indicated that the building need to find passive solution for solving humidity problem, that can be divided into two ways which raising ventilation and indoor temperature including increasing wind-flow ventilation and adjusting thermal temperature, for example; improving building design and stack driven ventilation. For raising indoor temperature or increasing mean radiant temperature, daylight can be passive solution for complex residential design for reducing humidity and enhance illumination indoor space simultaneous.

  14. Integrated residential photovoltaic array development

    Science.gov (United States)

    Royal, G. C., III

    1981-04-01

    Sixteen conceptual designs of residential photovoltaic arrays are described. Each design concept was evaluated by an industry advisory panel using a comprehensive set of technical, economic and institutional criteria. Key electrical and mechanical concerns that effect further array subsystem development are also discussed. Three integrated array design concepts were selected by the advisory panel for further optimization and development. From these concepts a single one will be selected for detailed analysis and prototype fabrication. The three concepts selected are: (1) An array of frameless panels/modules sealed in a T shaped zipper locking neoprene gasket grid pressure fitted into an extruded aluminum channel grid fastened across the rafters. (2) An array of frameless modules pressure fitted in a series of zipper locking EPDM rubber extrusions adhesively bonded to the roof. Series string voltage is developed using a set of integral tongue connectors and positioning blocks. (3) An array of frameless modules sealed by a silicone adhesive in a prefabricated grid of rigid tape and sheet metal attached to the roof.

  15. TOXIC EFFECTS OF CADMIUM

    Directory of Open Access Journals (Sweden)

    Tanja Vukićević

    2012-01-01

    Full Text Available Cadmium is one of the heavy metals, it is often used in industry, and exerts toxic effects on human health. Cadmium is classified as a carcinogenic substance for humans by the International Agency for Research on Cancer and is in a group I carcinogen. Cadmium affects the development of cell cycle, proliferation, differentiation, DNA repair, replication and apoptosis, as well as promotion of cancer in tissues. Intoxication with cadmium in people usually occurs by inhalation of cigarette smoke, but it is also possible via water, food and air. Cadmium exerts toxic effects on the kidneys, liver, lungs, cardiovascular system, immune system and reproductive system. Metallothionein protects tissues from the toxicity of cadmium. Cadmium-metallothionein complex is distributed in various tissues. There is no way for natural cadmium elimination from the human body. The main route of cadmium in the body is through binding with metallothionein, low molecular weight protein that participates in the homeostasis of certain metals. Cadmium-metallothionein complex is distributed in various tissues. The role of metallothionein in detoxification of cadmium is primarily in the large binding affinity of metals for metallothionein.

  16. Epidermal characteristics of toxic plants for cattle from the Salado River basin (Buenos Aires, Argentina Caracteres epidérmicos de las plantas tóxicas para el ganado de la Depresión del Salado (Buenos Aires, Argentina

    Directory of Open Access Journals (Sweden)

    Susana E. Freire

    2005-12-01

    Full Text Available One hundred and eighty species belonging to 41 families inhabiting the Salado River Basin of the province of Buenos Aires (Argentina were previously reported to be toxic for cattle. The purpose of this study was to provide a tool to distinguish the taxa when the plant material is desintegrated. In this way, an approach to the identification of these taxa through leaf epidermal features (anticlinal epidermal cell wall patterns, cuticular ornamentation, stomata, and hair types is performed. A key to the 180 species as well as illustrations of diagnostic characters are given.Las plantas tóxicas para el ganado están representadas en la Depresión del Salado (provincia de Buenos Aires, Argentina por 180 especies pertenecientes a 41 familias. El objetivo del presente trabajo es determinar estos taxa a partir de material desintegrado, utilizando caracteres epidérmicos foliares (paredes anticlinales de las células epidérmicas, ornamentación de la cutícula, tipos de estomas y pelos. Se brinda una clave para la determinación de las especies e ilustraciones de los caracteres diagnósticos.

  17. Toxic shock syndrome

    Science.gov (United States)

    Staphylococcal toxic shock syndrome; Toxic shock-like syndrome; TSLS ... Toxic shock syndrome is caused by a toxin produced by some types of staphylococcus bacteria. A similar problem, called toxic shock- ...

  18. Residential care: Dutch and Italian residents of residential care facilities compared.

    Science.gov (United States)

    de Heer-Wunderink, Charlotte; Caro-Nienhuis, Annemarie D; Sytema, Sjoerd; Wiersma, Durk

    2008-01-01

    Characteristics of patients living in residential care facilities and the availability of mental hospital- and residential beds in Italy and The Netherlands were compared to assess whether differences in the process of deinstitutionalisation have influenced the composition of their residential patient populations. Data from the Dutch UTOPIA-study (UTilization & Outcome of Patients In the Association of Dutch residential care providers) and the Italian PROGRES-study were used. Dutch residents were more likely to suffer from substance or alcohol abuse than Italian residents. The latter were more likely to suffer from schizophrenia or a related disorder, less likely to have experienced mental hospital admissions and showed an overall shorter duration of stay in residential care facilities. Contrary to our expectations Dutch residents, who still have good access to long stay beds in mental hospitals, are not less disabled than Italian residents. Finally, the number of beds in residential care facilities per 10,000 inhabitants in the Netherlands is twice (6) as high as in Italy (3). The Italian and Dutch deinstitutionalisation processes have resulted in a different availability in the number of residential beds. However, it did not influence the overall level of functioning of both residential populations.

  19. Differences between Residential and Non-Residential Fathers on Sexual Socialisation of African American Youth

    Science.gov (United States)

    Sneed, Carl D.; Willis, Leigh A.

    2016-01-01

    This study investigated differences between residential and non-residential fathers on topics discussed during father-child sex communication and factors associated with child sexual socialisation. Young people (N = 159, 53% female) provided self-reports using computer surveys on the role of their fathers on father-child sex communication, general…

  20. QUANTIFYING SUBGRID POLLUTANT VARIABILITY IN EULERIAN AIR QUALITY MODELS

    Science.gov (United States)

    In order to properly assess human risk due to exposure to hazardous air pollutants or air toxics, detailed information is needed on the location and magnitude of ambient air toxic concentrations. Regional scale Eulerian air quality models are typically limited to relatively coar...

  1. Manufactured Residential Utility Wall System (ResCore),

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Robert [Oak Ridge National Lab., TN (United States); Lundell, Clark; Lau, Tin Man [Auburn Univ., AL (United States)

    1997-12-31

    This paper describes the design and development of a manufactured residential utility wall system referred to as ResCore. ResCore is a self contained, manufactured, residential utility wall that provides complete rough-in of utilities (power, gas, water, and phone) and other functions (exhaust, combustion make-up air, refrigerant lines, etc.) to serve the kitchen, bath, utility, and laundry rooms. Auburn University, Department of Industrial Design faculty, students, supported by a team of graduate student researchers and the project`s advisory team, developed the ResCore. The project was accomplished through a research subcontract from the U.S. Department of Energy administered by the Oak Ridge National Laboratory. The ResCore wall system features a layered manufacturing technique that allows each major component group: structural, cold water, hot water, drain, gas, electric, etc. to be built as a separate subassembly and easily brought together for final assembly. The two structural layers are reinforced with bridging that adds strength and also permits firm attachment of plumbing pipes and other systems to the wall frame.

  2. In-home performance of residential cordwood stoves

    International Nuclear Information System (INIS)

    Houck, J.E.; Barnett, S.G.; Roholt, R.B.

    1991-01-01

    The air quality impacts of residential cordwood stoves have been of concern to regulators, energy planners, and members of the woodstove industry. In addition, the reliability of laboratory certification emission values in predicting 'real world' emissions has been questioned. In response to these concerns, particulate emissions from residential cordwood stoves under actual in-home use have been measured for 5 heating seasons as part of 12 separate studies in Oregon, New York, Vermont, and the Yukon Territory. Monitoring was conducted using an automated emission sampler (AES) system. The system has been deployed in nearly 100 individual homes. Typically, emissions from several 1-week-long integrated sampling periods over the course of the heating season were measured with the AES system at each home. Particulate emission rates in grams of particles per hour of stove operation, grams of particles per kilogram of dry wood burned, and grams of particles per million Joules were calculated. Ancillary data provided by the studies included wood burn rates, homeowner wood loading patterns, wood moisture content and species, hours of operation of auxiliary heating appliances in the study homes, room ambient, flue gas, catalyst, and pre-catalyst temperatures, and hours of catalyst operation. Conventional stoves, high-technology non-catalytic stoves, catalytic stoves, and stoves equipped with retrofit catalytic devices have been studied. In addition to the 12 cordwood stove studies, the AES system has been used in 2 pellet stove studies and 1 fireplace study

  3. An overview of particulate emissions from residential biomass combustion

    Science.gov (United States)

    Vicente, E. D.; Alves, C. A.

    2018-01-01

    Residential biomass burning has been pointed out as one of the largest sources of fine particles in the global troposphere with serious impacts on air quality, climate and human health. Quantitative estimations of the contribution of this source to the atmospheric particulate matter levels are hard to obtain, because emission factors vary greatly with wood type, combustion equipment and operating conditions. Updated information should improve not only regional and global biomass burning emission inventories, but also the input for atmospheric models. In this work, an extensive tabulation of particulate matter emission factors obtained worldwide is presented and critically evaluated. Existing quantifications and the suitability of specific organic markers to assign the input of residential biomass combustion to the ambient carbonaceous aerosol are also discussed. Based on these organic markers or other tracers, estimates of the contribution of this sector to observed particulate levels by receptor models for different regions around the world are compiled. Key areas requiring future research are highlighted and briefly discussed.

  4. Perception Analysis Of Living Environment At Taman Melati Residential Areas

    Directory of Open Access Journals (Sweden)

    ABDUL AZEEZ Kadar Hamsa

    2010-12-01

    Full Text Available Rapid physical development in a residential area will deteriorate living environment of the residents especially if it takes place haphazardly without applying adequate planning guidelines. It will, eventually, exert more pressure on physical infrastructure of the area. As a result, residents of the area will be subjected to dissatisfaction on the present supporting infrastructure as the demand exceeds the supply. Evidently, it may lead to poor living conditions of the area, which ultimately slow the progressiveness of the society to achieve the quality of living standards. This paper investigates residents' perceptions on present living environmental setting at Taman Melati residential area in Kuala Lumpur. Questionnaire survey was administered to determine the perceptions of the residents on physical environmental parameters such as air, noise, streetlight illuminance, and traffic volume. The level of satisfaction of the residents on the living environment had showed nearly 64% of the respondents expressed 'satisfied strongly' or 'satisfied'. The level of willingness of the residents to stay further continuously at Taman Melati indicates about 56% of the respondents expressed 'strongly willing' or 'willing'. It is also seen that the overall satisfaction level of the residents on the living environment was high albeit satisfaction level on individual physical environmental parameters was low.

  5. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  6. Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal

    2017-10-01

    Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.

  7. Residentialization of Public Spaces: Bratislava Example

    Science.gov (United States)

    Bacová, Andrea; Puškár, Branislav; Vráblová, Edita

    2017-10-01

    The housing estates in Bratislava saturated the housing needs of a large number of inhabitants who come after World War II to the city. Design of public spaces often did not have priority in the process of designing. The solutions for mentioned exterior spaces had been planned after blocks of flat realization, but many of them are not realized to this day. The article analyzes the example of the unrealized public spaces in existing housing estates Devinska Nova Ves and Petržalka (city districts of Bratislava) and offer practical solutions in relation to residencialization method. Residencialization of missing public places is an effective method of adding identities to settlements. It improves the quality of residential environment and public spaces. The main aim is to create better conditions for social activities in public areas, which are missing on the present. The research will be focused on the examination of the urban, cultural and construction potential of the existing residential enviroment in Bratislava. The main aim of residentialization is not only to enhance the quality of spatial and building structures in the selected residential area and maintain long-term sustainability in the pertinent programme area, but mainly to improve the quality of living for the residents. The outputs of the project are proposals and practical procedures developed with regard to planning documents for local municipal authorities and regional organizations. The solutions will have a positive impact on the enhancement of the quality of public spaces, attractive social activities and of a conceptual link - residentialization.

  8. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  9. A fugacity-based indoor residential pesticide fate model

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Deborah H.; Furtaw, Edward J.; McKone, Thomas E.

    2002-06-01

    Dermal and non-dietary pathways are potentially significant exposure pathways to pesticides used in residences. Exposure pathways include dermal contact with residues on surfaces, ingestion from hand- and object-to-mouth activities, and absorption of pesticides into food. A limited amount of data has been collected on pesticide concentrations in various residential compartments following an application. But models are needed to interpret this data and make predictions about other pesticides based on chemical properties. In this paper, we propose a mass-balance compartment model based on fugacity principles. We include air (both gas phase and aerosols), carpet, smooth flooring, and walls as model compartments. Pesticide concentrations on furniture and toys, and in food, are being added to the model as data becomes available. We determine the compartmental fugacity capacity and mass transfer-rate coefficient for wallboard as an example. We also present the framework and equations needed for a dynamic mass-balance model.

  10. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  11. Estimation of energy efficiency of residential buildings

    Directory of Open Access Journals (Sweden)

    Glushkov Sergey

    2017-01-01

    Full Text Available Increasing energy performance of the residential buildings by means of reducing heat consumption on the heating and ventilation is the last segment in the system of energy resources saving. The first segments in the energy saving process are heat producing and transportation over the main lines and outside distribution networks. In the period from 2006 to 2013. by means of the heat-supply schemes optimization and modernization of the heating systems. using expensive (200–300 $US per 1 m though hugely effective preliminary coated pipes. the economy reached 2.7 mln tons of fuel equivalent. Considering the multi-stage and multifactorial nature (electricity. heat and water supply of the residential sector energy saving. the reasonable estimate of the efficiency of the saving of residential buildings energy should be performed in tons of fuel equivalent per unit of time.

  12. Gentrification and Residential Mobility in Philadelphia.

    Science.gov (United States)

    Ding, Lei; Hwang, Jackelyn; Divringi, Eileen

    2016-11-01

    Gentrification has provoked considerable controversy surrounding its effects on residential displacement. Using a unique individual-level, longitudinal data set, this study examines mobility rates and residential destinations of residents in gentrifying neighborhoods during the recent housing boom and bust in Philadelphia for various strata of residents and different types of gentrification. We find that vulnerable residents, those with low credit scores and without mortgages, are generally no more likely to move from gentrifying neighborhoods compared with their counterparts in nongentrifying neighborhoods. When they do move, however, they are more likely to move to lower-income neighborhoods. Residents in gentrifying neighborhoods at the aggregate level have slightly higher mobility rates, but these rates are largely driven by more advantaged residents. These findings shed new light on the heterogeneity in mobility patterns across residents in gentrifying neighborhoods and suggest that researchers should focus more attention on the quality of residential moves and nonmoves for less advantaged residents, rather than mobility rates alone.

  13. Therapeutic Residential Care for Children and Youth:

    DEFF Research Database (Denmark)

    Whittaker, James K.; Holmes, Lisa; del Valle, Jorge F.

    2016-01-01

    for Child and Family Research, Loughborough University in the U.K. for a Summit meeting on therapeutic residential care for children and youth funded by the Sir Halley Stewart Trust (UK). The focus centered on what is known about therapeutic residential care and what key questions should inform a priority......In many developed countries around the world, ‘group care’ interventions for children and adolescents have come under increasing scrutiny from central government, private philanthropic and child advocacy agencies desirous of (1) achieving better outcomes for vulnerable children and youth; (2) doing...... alternatives to serve high-resource needing youth has had unintended and negative consequences. It is within this context that a working group international experts representing research, policy, service delivery and families (International Work Group for Therapeutic Residential Care) convened at the Centre...

  14. Solar Photovoltaic Financing: Residential Sector Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.; Cory, K.

    2009-03-01

    This report presents the information that homeowners and policy makers need to facilitate PV financing at the residential level. The full range of cash payments, bill savings, and tax incentives is covered, as well as potentially available solar attribute payments. Traditional financing is also compared to innovative solutions, many of which are borrowed from the commercial sector. Together, these mechanisms are critical for making the economic case for a residential PV installation, given its high upfront costs. Unfortunately, these programs are presently limited to select locations around the country. By calling attention to these innovative initiatives, this report aims to help policy makers consider greater adoption of these models to benefit homeowners interested installing a residential PV system.

  15. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  16. Modelling and forecasting Turkish residential electricity demand

    International Nuclear Information System (INIS)

    Dilaver, Zafer; Hunt, Lester C

    2011-01-01

    This research investigates the relationship between Turkish residential electricity consumption, household total final consumption expenditure and residential electricity prices by applying the structural time series model to annual data over the period from 1960 to 2008. Household total final consumption expenditure, real energy prices and an underlying energy demand trend are found to be important drivers of Turkish residential electricity demand with the estimated short run and the long run total final consumption expenditure elasticities being 0.38 and 1.57, respectively, and the estimated short run and long run price elasticities being -0.09 and -0.38, respectively. Moreover, the estimated underlying energy demand trend, (which, as far as is known, has not been investigated before for the Turkish residential sector) should be of some benefit to Turkish decision makers in terms of energy planning. It provides information about the impact of past policies, the influence of technical progress, the impacts of changes in consumer behaviour and the effects of changes in economic structure. Furthermore, based on the estimated equation, and different forecast assumptions, it is predicted that Turkish residential electricity demand will be somewhere between 48 and 80 TWh by 2020 compared to 40 TWh in 2008. - Research highlights: → Estimated short run and long run expenditure elasticities of 0.38 and 1.57, respectively. → Estimated short run and long run price elasticities of -0.09 and -0.38, respectively. → Estimated UEDT has increasing (i.e. energy using) and decreasing (i.e. energy saving) periods. → Predicted Turkish residential electricity demand between 48 and 80 TWh in 2020.

  17. The diversity and distribution of fungi on residential surfaces.

    Directory of Open Access Journals (Sweden)

    Rachel I Adams

    Full Text Available The predominant hypothesis regarding the composition of microbial assemblages in indoor environments is that fungal assemblages are structured by outdoor air with a moderate contribution by surface growth, whereas indoor bacterial assemblages represent a mixture of bacteria entered from outdoor air, shed by building inhabitants, and grown on surfaces. To test the fungal aspect of this hypothesis, we sampled fungi from three surface types likely to support growth and therefore possible contributors of fungi to indoor air: drains in kitchens and bathrooms, sills beneath condensation-prone windows, and skin of human inhabitants. Sampling was done in replicated units of a university-housing complex without reported mold problems, and sequences were analyzed using both QIIME and the new UPARSE approach to OTU-binning, to the same result. Surfaces demonstrated a mycological profile similar to that of outdoor air from the same locality, and assemblages clustered by surface type. "Weedy" genera typical of indoor air, such as Cladosporium and Cryptococcus, were abundant on sills, as were a diverse set of fungi of likely outdoor origin. Drains supported more depauperate assemblages than the other surfaces and contained thermotolerant genera such as Exophiala, Candida, and Fusarium. Most surprising was the composition detected on residents' foreheads. In addition to harboring Malassezia, a known human commensal, skin also possessed a surprising richness of non-resident fungi, including plant pathogens such as ergot (Claviceps purperea. Overall, fungal richness across indoor surfaces was high, but based on known autecologies, most of these fungi were unlikely to be growing on surfaces. We conclude that while some endogenous fungal growth on typical household surfaces does occur, particularly on drains and skin, all residential surfaces appear - to varying degrees - to be passive collectors of airborne fungi of putative outdoor origin, a view of the origins

  18. Strategy Guideline: High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J.

    2012-02-01

    The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

  19. Toxic metal pollution in Africa.

    Science.gov (United States)

    Nriagu, J O

    1992-06-30

    The available information suggests that the concentrations of toxic metals in many ecosystems of Africa are reaching unprecedented levels. Because of the heavy load of contaminated dusts in the air of the overcrowded cities, the ambient concentrations of toxic metals are now among the highest being reported anywhere. Lead pollution from the increasing number of automobiles and cottage industries represents a major health hazard, and it is estimated that 15-30% of the infants in some urban areas may already be suffering from lead poisoning. The cultural and lifestyle determinants of lead exposure and the greater susceptibility of African populations to environmental metal poisoning are highlighted. The suggestion is made that the environmental health criteria for toxic metals in the developed countries may not provide adequate protection for many African communities.

  20. Steering Angle Function Algorithm of Morphing of Residential Area

    Directory of Open Access Journals (Sweden)

    XIE Tian

    2015-07-01

    Full Text Available A residential area feature morphing method based on steering angle function is presented. To residential area with the same representation under two different scales,transforming the representation of the residential area polygon from vector coordinates to steering angle function,then using the steering angle function to match,and finding out the similarity and the differences between the residential areas under different scale to get the steering angle function of the the residential areas under any middle scale,the final,transforming the middle scale steering angle function to vector coordinates form,and get the middle shape interpolation of the the residential area polygon.Experimental results show:the residential area morphing method by using steering angle function presented can realize the continuous multi-scale representation under the premise of keeping in shape for the residential area with the rectangular boundary features.

  1. Use of Electronic Health Records in Residential Care Communities

    Science.gov (United States)

    ... the National Technical Information Service NCHS Use of Electronic Health Records in Residential Care Communities Recommend on ... Facilities Most residential care communities did not use electronic health records in 2010, and use varied by ...

  2. PRN 2011-1: Residential Exposure Joint Venture

    Science.gov (United States)

    This PR Notice is to advise registrants of an industry-wide joint venture, titled the Residential Exposure Joint Venture (REJV), which has developed a national survey regarding residential consumer use/usage data for pesticides.

  3. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  4. 78 FR 7487 - National Emission Standards for Hazardous Air Pollutants for Area Sources: Industrial, Commercial...

    Science.gov (United States)

    2013-02-01

    ... technologies HAP hazardous air pollutants Hg mercury HQ Headquarters ISO International Standards Organization... services and drinking places. 62 Health care and social assistance. 22111 Electric power generation. \\a...: Residential boiler means a boiler used to provide heat and/or hot water and/or as part of a residential...

  5. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  6. The state of the residential fire fatality problem in Sweden: Epidemiology, risk factors, and event typologies.

    Science.gov (United States)

    Jonsson, Anders; Bonander, Carl; Nilson, Finn; Huss, Fredrik

    2017-09-01

    Residential fires represent the largest category of fatal fires in Sweden. The purpose of this study was to describe the epidemiology of fatal residential fires in Sweden and to identify clusters of events. Data was collected from a database that combines information on fatal fires with data from forensic examinations and the Swedish Cause of Death-register. Mortality rates were calculated for different strata using population statistics and rescue service turnout reports. Cluster analysis was performed using multiple correspondence analysis with agglomerative hierarchical clustering. Male sex, old age, smoking, and alcohol were identified as risk factors, and the most common primary injury diagnosis was exposure to toxic gases. Compared to non-fatal fires, fatal residential fires more often originated in the bedroom, were more often caused by smoking, and were more likely to occur at night. Six clusters were identified. The first two clusters were both smoking-related, but were separated into (1) fatalities that often involved elderly people, usually female, whose clothes were ignited (17% of the sample), (2) middle-aged (45-64years old), (often) intoxicated men, where the fire usually originated in furniture (30%). Other clusters that were identified in the analysis were related to (3) fires caused by technical fault, started in electrical installations in single houses (13%), (4) cooking appliances left on (8%), (5) events with unknown cause, room and object of origin (25%), and (6) deliberately set fires (7%). Fatal residential fires were unevenly distributed in the Swedish population. To further reduce the incidence of fire mortality, specialized prevention efforts that focus on the different needs of each cluster are required. Cooperation between various societal functions, e.g. rescue services, elderly care, psychiatric clinics and other social services, with an application of both human and technological interventions, should reduce residential fire

  7. An application of energy and exergy analysis in residential sector of Malaysia

    International Nuclear Information System (INIS)

    Saidur, R.; Masjuki, H.H.; Jamaluddin, M.Y.

    2007-01-01

    In this paper, the useful concept of energy and exergy utilization is defined, analyzed and applied to the residential sector of Malaysia by taking into account the energy and exergy flows for a period of 8 years from the year 1997 to 2004. The energy and exergy efficiencies are determined for the devices used in this sector and found to be 70% and 28%, respectively. Energy and exergy flow diagrams for the overall efficiencies of Malaysian residential sector are also illustrated in this paper. It is found that the current methodology applied in Saudi Arabia is suitable to analyze energy and exergy use in Malaysian residential sector. It has been found that the exergy efficiency of the Malaysian residential sector appears to be much lower than its corresponding energy efficiency. It has been observed that about 21% of total exergy losses are caused by refrigerator-freezer and 12% of total loss is caused by air conditioner. Washing machine, fan and rice cooker contribute about 11%, 10% and 8% of total exergy losses, respectively

  8. Impact of wood combustion on particle levels in a residential area in Denmark

    DEFF Research Database (Denmark)

    Glasius, M.; Ketzel, M.; Wåhlin, P.

    2006-01-01

    The influence of residential wood-combustion on local air quality was studied during two periods in 2002 and 2003/04 in a small rural town with widespread use of wood combustion for heating. During one 6-week winter period, particle levels (PM2.5) in the residential area were about 4 μg m-3 higher...... than at a nearby background site. This was comparable to the local traffic contribution observed at a busy street (about 70,000 vehicles per day) in the city of Copenhagen. The diurnal variation in the residential area showed increased particle levels (PM2.5) in the evening and night as expected from...... local heating sources. Particle size distributions showed highest volume concentrations of particles with diameters of 400-500 nm, and the diurnal variation of particle volume was similar to PM2.5. The particle measurements were supported by measurements of combustion gases in both the residential area...

  9. Residential Group Care Quarterly. Volume 5, Number 3, Winter 2005

    Science.gov (United States)

    Michael, Jennifer, Ed.

    2005-01-01

    This issue of "Residential Group Care Quarterly" contains the following articles: (1) "Promising Practices for Adequately Funding and Reimbursing Residential Services" (Lloyd Bullard); (2) "Closing the Gender Gap" (Erin Andersen); (3) "Residential Child Care: Guidelines for Physical Techniques, Crisis Prevention, and Management" (Kurk Lalemand);…

  10. Family events and the residential mobility of couples

    NARCIS (Netherlands)

    Michielin, F.; Mulder, C.H.

    2008-01-01

    Using data from retrospective surveys carried out in the Netherlands during the early 1990s, we describe how the residential mobility of couples—that is, short-distance moves—is affected by family events and how fertility is affected by residential mobility. The results show that residential moves

  11. Air Conditioning and Refrigeration Book III.

    Science.gov (United States)

    Eckes, William; Fulkerson, Dan

    Designed to present theory as a functional aspect, this air conditioning and refrigeration curriculum guide is comprised of nine units of instruction. Unit titles include (1) Job Orientation, (2) Applying for a Job, (3) Customer Relations, (4) Business Management, (5) Psychometrics, (6) Residential Heat Loss and Heat Gain, (7) Duct Design and…

  12. Solar-powered air-conditioning

    Science.gov (United States)

    Clark, D. C.; Rousseau, J.

    1977-01-01

    Report focuses on recent study on development of solar-powered residential air conditioners and is based on selected literature through 1975. Its purposes are to characterize thermal and mechanical systems that might be useful in development of Rankine-cycle approach to solar cooling and assessment of a Lithium Bromide/Water absorption cycle system.

  13. Electricity: Residential Wiring. Secondary Schools. Curriculum Guide.

    Science.gov (United States)

    Trust Territory of the Pacific Islands Dept. of Education, Saipan.

    This curriculum guide on residential wiring for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of…

  14. Guidelines for Transferring Residential Courses into Web

    Science.gov (United States)

    Tüzün, Hakan; Çinar, Murat

    2016-01-01

    This study shared unique design experiences by examining the process of transferring residential courses to the Web, and proposed a design model for individuals who want to transfer their courses into this environment. The formative research method was used in the study, and two project teams' processes of putting courses, which were being taught…

  15. DETERMINANTS OF RESIDENTIAL PER CAPITA WATER ...

    African Journals Online (AJOL)

    This report presents the findings of the study on the determinants of residential per capita water demand of Makurdi metropolis in Benue State, Nigeria. Data for the study was obtained by the use of questionnaires, oral interviews and observations. The data was analyzed using SPSS. Twenty variables were considered in ...

  16. Condition assessment and strengthening of residential units

    Directory of Open Access Journals (Sweden)

    Tatheer Zahra

    2014-01-01

    Full Text Available About 40, ground plus one (G+1 residential units were designed using a hybrid structural framing system (RC frame and load bearing walls. A few months after the completion of the ground floor of the residential units, cracks appeared at several locations in the structure. Field and Laboratory testing was conducted to ascertain the in situ strength of concrete and steel reinforcement. The results of the experimental work were used in the analytical ETABS model for the structural stability calculations. The results indicated that residential units were marginally safe in the existing condition (completed ground floor, but the anticipated construction of the floor above the ground floor (G+1 could not be carried out as the strength of the structural system was inadequate. To increase the safety of existing ground floor and to provide the option of the construction of one floor above, rehabilitation and strengthening design was performed. The proposed strengthening design made use of welded wire fabric (WWF and carbon fibre reinforced polymer (CFRP laminates/sheets for the strengthening of walls, columns and slabs. The residential units will be strengthened in the near future.

  17. Chapter 6: Residential Lighting Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Dimetrosky, Scott [Apex Analytics LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics LLC, Boulder, CO (United States)

    2015-02-01

    In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

  18. housing tenure, residential moves and children's educational

    African Journals Online (AJOL)

    User

    ABSTRACT. Research has shown that non-conventional factors like housing and residential experiences dur- ing childhood have impacts on children's success. Given the critical importance of human capi- tal accumulation in Ghana, it is significant from policy standpoint to recognise factors and mechanisms that are ...

  19. Housing tenure, residential moves and children's educational ...

    African Journals Online (AJOL)

    Research has shown that non-conventional factors like housing and residential experiences during childhood have impacts on children's success. Given the critical importance of human capital accumulation in Ghana, it is significant from policy standpoint to recognise factors and mechanisms that are relevant to the next ...

  20. Application of solar energy to air-conditioning

    Science.gov (United States)

    Harstad, A. J.; Nash, J. M.

    1978-01-01

    Results of survey of application of solar energy to air-conditioning systems are summarized in report. Survey reviewed air-conditioning techniques that are most likely to find residential applications and that are compatible with solar-energy systems being developed.

  1. Air Conditioning and Refrigeration Program Articulation, 1981-1982.

    Science.gov (United States)

    Dallas County Community Coll. District, TX.

    Based on a survey of high school programs and courses in the Dallas County Community College District (DCCCD), this articulated program is designed to prepare students for entry-level employment in the air conditioning and refrigeration industry, including residential and commercial air conditioning and commercial refrigeration. The skills and…

  2. Information Processing and Creative Thinking Abilities of Residential and Non-Residential School Children

    Directory of Open Access Journals (Sweden)

    Atasi Mohanty

    2015-10-01

    Full Text Available This study attempts to assess and compare the residential and non-residential schoolchildren in information-processing skills and creative thinking abilities. A sample of 80 children from Classes 5 and 7 were selected from two types of schools, residential/ashram (02 and non-residential/formal schools (02 in Bolpur subdivision of West Bengal in India where the medium of instruction is Bengali language/mother-tongue. All the children were individually administered the PASS (Planning, Attention, Simultaneous, Successive, Stroop, Matching Familiar Figure Test (MFFT-20, and creative thinking tasks. The residential school children were found to perform better both in information processing and creative thinking tasks. The developmental trend could not be clearly observed due to small sample size, but with increasing age, children were using better processing strategies. Due to ashram environment, creative pedagogy, and various co-curricular activities, the residential school children were found to be more creative than their formal school counterparts. Moreover, some significant positive correlations were found among information processing skills and creative thinking dimensions.

  3. Development of a residential wood smoke reduction plan in a wood burning community: A case study in Libby, Montana

    International Nuclear Information System (INIS)

    Fox, R.J.; Manderino, L.; Lyons, C.E.; Morris, A.L.; Anderson, R.L.

    1992-01-01

    Libby, Montana depends on wood as a heating fuel. Libby exceeded the 24-hour federal PM10 ambient air quality standard every year since monitoring began in 1987. Residential wood smoke significantly contributes to its air pollution. To decrease residential wood smoke's contribution to air pollution, residents have to modify their heating habits. County officials sponsored the development of a comprehensive community-oriented plan to reduce wood smoke. This paper describes how the plan was developed and the components of the air pollution reduction strategies. The plan was developed using community input and tailored to local conditions. Four specific strategies were developed to reduce residential wood smoke pollution. Development of strategies required analysis of home heating habits and potential alternatives. Economic conditions were also considered. Expensive control strategies would be worthless unless alternative funding methods were provided. Thus, the plan included an array of funding sources to facilitate implementation. The development and implementation techniques are applicable to other communities with similar air pollution challenges

  4. Spatial/temporal variations of elemental carbon, organic carbon, and trace elements in PM10 and the impact of land-use patterns on community air pollution in Paterson, NJ.

    Science.gov (United States)

    Yu, Chang Ho; Fan, Zhi-Hua; Meng, Qingyu; Zhu, Xianlei; Korn, Leo; Bonanno, Linda J

    2011-06-01

    An urban community PM10 (particulate matter NJ, a mixed land-use community that is interspersed with industrial, commercial, mobile, and residential land-use types. This paper examines (1) the spatial/temporal variation of PM10, elemental carbon (EC), organic carbon (OC), and nine elements; and (2) the impact of land-use type on those variations. Air samples were collected from three community-oriented locations in Paterson that attempted to capture industrial, commercial, and mobile source-dominated emissions. Sampling was conducted for 24 hr every 6 days from November 2005 through December 2006. Samples were concurrently collected at the New Jersey Department of Environmental Protection-designated air toxics background site in Chester, NJ. PM10 mass, EC, OC, and nine elements (Ca, Cu, Fe, Pb, Mn, Ni, S, Ti, and Zn) that had more than 50% of samples above detection and known sources or are toxic were selected for spatial/temporal analysis in this study. The concentrations of PM10, EC, OC, and eight elements (except S) were significantly higher in Paterson than in Chester (P 0.05). These results indicated that anthropogenic sources of air pollution were present in Paterson. The source apportionment confirmed the impact of vehicular and industrial emissions on the PM10 ambient air pollution in Paterson. The multiple linear regression analysis showed that categorical land-use type was a significant predictor for all air pollution levels, explaining up to 42% of the variability in concentration by land-use type only.

  5. Air Inflated Greenhouse as Urban Farming Facilities: Architectural Overview

    OpenAIRE

    Abidin, Syed Zainol; Nasihien, Ronny D; Budiyanto, Hery

    2017-01-01

    Urban Farming utilizing land intensification, in order to meet the needs of fresh vegetables and fruits everyday for the community residential / housing in urban areas. Air Inflated Greenhouse as urban farming facilities, can be built and transferred to a residential location / specific housing is easy, safe, fast and lightweight (0,55mm PVC tarpaulin) so that urban farming products closer to consumers in urban settlements, the price impact getting cheaper, but quality. Long-term goal is to d...

  6. Energy Impacts of Envelope Tightening and Mechanical Ventilation for the U.S. Residential Sector

    Energy Technology Data Exchange (ETDEWEB)

    Logue, J. M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, M. H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, I. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, B. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-01-01

    Effective residential envelope air sealing reduces infiltration and associated energy costs for thermal conditioning, yet often creates a need for mechanical ventilation to protect indoor air quality. This study estimated the potential energy savings of implementing airtightness improvements or absolute standards along with mechanical ventilation throughout the U.S. housing stock. We used a physics-based modeling framework to simulate the impact of envelope tightening, providing mechanical ventilation as needed. There are 113 million homes in the US. We calculated the change in energy demand for each home in a nationally representative sample of 50,000 virtual homes developed from the 2009 Residential Energy Consumption Survey. Ventilation was provided as required by 2010 and proposed 2013 versions of ASHRAE Standard 62.2. Ensuring that all current homes comply with 62.2-2010 would increase residential site energy demand by 0.07 quads (0.07 exajoules (EJ)) annually. Improving airtightness of all homes at current average retrofit performance levels would decrease demand by 0.7 quads (0.74 EJ) annually and upgrading all homes to be as airtight as the top 10% of similar homes would double the savings, leading to roughly $22 billion in annual savings in energy bills. We also analyzed the potential benefits of bringing the entire stock to airtightness specifications of IECC 2012, Canada's R2000, and Passive House standards.

  7. Distributed Structure Searchable Toxicity

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Distributed Structure Searchable Toxicity (DSSTox) online resource provides high quality chemical structures and annotations in association with toxicity data....

  8. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  9. RESULTS OF RESEARCH OF AIR POLLUTION BY AUTOMOBILE TRANSPORT IN THE STREETS OF KHARKIV

    Directory of Open Access Journals (Sweden)

    Lezhneva, E.

    2013-06-01

    Full Text Available Results of the research of the atmospheric air of residential area roadside territory at functioning of motor transport are presented. Architectural and planning activities to improve the environmental performance of the local area of Kharkiv are offered.

  10. Health impacts due to personal exposure to fine particles caused by insulation of residential buildings in Europe

    Science.gov (United States)

    Gens, Alexandra; Hurley, J. Fintan; Tuomisto, Jouni T.; Friedrich, Rainer

    2014-02-01

    The insulation of residential buildings affects human exposure to fine particles. According to current EU guidelines, insulation is regulated for energy saving reasons. As buildings become tighter, the air exchange rate is reduced and, thus, the indoor concentration of pollutants is increased if there are significant indoor sources. While usually the effects of heat insulation and increase of the air-tightness of buildings on greenhouse gas emissions are highlighted, the negative impacts on human health due to higher indoor concentrations are not addressed. Thus, we investigated these impacts using scenarios in three European countries, i. e. Czech Republic, Switzerland and Greece. The assessment was based on modelling the human exposure to fine particles originating from sources of particles within outdoor and indoor air, including environmental tobacco smoke. Exposure response relationships were derived to link (adverse) health effects to the exposure. Furthermore, probable values for the parameters influencing the infiltration of fine particles into residential buildings were modelled. Results show that the insulation and increase of the air-tightness of residential buildings leads to an overall increase of the mean population exposure - and consequently adverse health effects - in all considered countries (ranging for health effects from 0.4% in Czech Republic to 11.8% in Greece for 100% insulated buildings) due to an accumulation of particles indoors, especially from environmental tobacco smoke. Considering only the emission reductions in outdoor air (omitting changes in infiltration parameters) leads to a decrease of adverse health effects. This study highlights the importance of ensuring a sufficient air exchange rate when insulating buildings, e. g. by prescribing heat ventilation and air conditioning systems in new buildings and information campaigns on good airing practice in renovated buildings. It also shows that assessing policy measures based on the

  11. Assessment of natural ventilation for Canadian residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Reardon, J.T. [National Research Council of Canada, Ottawa, ON (Canada)

    2007-08-13

    There are generally two types of ventilation in houses, notably natural infiltration produced by stack and wind pressures, and mechanical ventilation by exhaust or intake fans operating across the house envelope. This research paper utilized historical data collected in Ottawa to establish those periods of low natural ventilation, when stack and wind pressures become so low that sufficient natural ventilation does not occur. Modelling and weather data was used to extend the analysis to other locations in Canada. This paper described the research project including its objectives and work plan. Each of the tasks in the study were explained. These included establishing a definition of adequate residential ventilation; establishing typical characteristics of Canadian dwellings; selecting a suitable air infiltration/natural ventilation model for houses; identifying measured data sets suitable for analysis; and reviewing selected data to determine periods of inadequate natural ventilation. Conclusions and future work were also presented. It was concluded that natural ventilation, at least due to air filtration, cannot be relied upon to provide all the ventilation needs in Canadian houses. Mechanical ventilation is needed in most Canadian houses to supplement natural ventilation during mild weather. 73 refs., 74 tabs., 7 figs., 3 appendices.

  12. Formaldehyde as a basis for residential ventilation rates

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, M.H.; Hodgson, A.T.

    2002-04-28

    Traditionally, houses in the U.S. have been ventilated by passive infiltration in combination with active window opening. However in recent years, the construction quality of residential building envelopes has been improved to reduce infiltration, and the use of windows for ventilation also may have decreased due to a number of factors. Thus, there has been increased interest in engineered ventilation systems for residences. The amount of ventilation provided by an engineered system should be set to protect occupants from unhealthy or objectionable exposures to indoor pollutants, while minimizing energy costs for conditioning incoming air. Determining the correct ventilation rate is a complex task, as there are numerous pollutants of potential concern, each having poorly characterized emission rates, and poorly defined acceptable levels of exposure. One ubiquitous pollutant in residences is formaldehyde. The sources of formaldehyde in new houses are reasonably understood, and there is a large body of literature on human health effects. This report examines the use of formaldehyde as a means of determining ventilation rates and uses existing data on emission rates of formaldehyde in new houses to derive recommended levels. Based on current, widely accepted concentration guidelines for formaldehyde, the minimum and guideline ventilation rates for most new houses are 0.28 and 0.5 air changes per hour, respectively.

  13. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  14. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  15. Residential Satisfaction in the Informal Neighborhoods of Ulaanbaatar, Mongolia

    Directory of Open Access Journals (Sweden)

    Jean Caldieron

    2013-03-01

    Full Text Available Residential satisfaction is a very important factor in determining the quality of life, housing improvement proposals, and adequate housing policies. This paper reports on the findings of a study in four informal neighborhoods or “ger districts” of Ulaanbaatar, the Mongolian capital. Mongolia has been facing an onslaught of rural migration to the urban areas because of two reasons. First, rural nomads have lost their livestock due to recent harsh climate conditions, and second because of the transition from communism to a democratic market economy, based on the exploitation of Mongolia’s rich mineral resources. In the cities, migrants have invaded land and erected rural nomadic “ger” (felt tents or yurts. The traditional ger (as they are called in the Mongolian language are sustainable structures well adapted for a nomadic society. However, when they are located in high-density, unplanned shantytowns, they create many issues. The country’s capital, Ulaanbaatar, is the coldest capital in the world; ger’ household use coal for heating which causes dense air pollution, especially in the winter. These informal urban areas lack sanitation, adequate vehicular access and other services. Eventually residents build small permanent houses, but they still lack for basic services. This paper presents the findings of more than one hundred household surveys related to housing conditions in three informal ger districts of Ulaanbaatar. The surveys were held in the summer of 2011. This paper discusses some of the characteristics of the settlements as well as the residential satisfaction of its inhabitants.

  16. Harmonizing human exposure and toxicity characterization

    DEFF Research Database (Denmark)

    Fantke, Peter; Jolliet, O.; McKone, T.E.

    2017-01-01

    The UNEP-SETAC Life Cycle Initiative has launched a project to provide global guidance and build consensus on environmental life cycle impact assessment (LCIA) indicators. Human health effects from exposure to toxic chemicals was selected as impact category due to high relevance of human toxicity...... and harmonizing human toxicity characterization in LCIA. Building on initial work for the far-field and indoor air environments, and combining it with latest work on near-field consumer and occupational exposure assessment, dose-response and severity data, we aim at providing revised guidance on the development...... and use of impact factors for toxic chemicals. We propose to couple fate processes in consumer and occupational environments with existing environmental compartments and processes via a consistent and mass balance-based set of transfer fractions to quantify overall aggregated exposure to toxic substances...

  17. Thermal Performance of Typical Residential Building in Karachi with Different Materials for Construction

    Directory of Open Access Journals (Sweden)

    Nafeesa Shaheen

    2016-04-01

    Full Text Available This research work deals with a study of a residential building located in climatic context of Karachi with the objective of being the study of thermal performance based upon passive design techniques. The study helps in reducing the electricity consumption by improving indoor temperatures. The existing residential buildings in Karachi were studied with reference to their planning and design, analyzed and evaluated. Different construction?s compositions of buildings were identified, surveyed and analyzed in making of the effective building envelops. Autodesk® Ecotect, 2011 was used to determine indoor comfort conditions and HVAC (Heating, Ventilation, Air-Conditioning and Cooling loads. The result of the research depicted significant energy savings of 38.5% in HVAC loads with proposed building envelop of locally available materials and glazing.

  18. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    This study combines principles of energy systems engineering and statistics to develop integrated models of residential energy use in the United States, to include residential recharging of electric vehicles. These models can be used by government, policymakers, and the utility industry to provide answers and guidance regarding the future of the U.S. energy system. Currently, electric power generation must match the total demand at each instant, following seasonal patterns and instantaneous fluctuations. Thus, one of the biggest drivers of costs and capacity requirement is the electricity demand that occurs during peak periods. These peak periods require utility companies to maintain operational capacity that often is underutilized, outdated, expensive, and inefficient. In light of this, flattening the demand curve has long been recognized as an effective way of cutting the cost of producing electricity and increasing overall efficiency. The problem is exacerbated by expected widespread adoption of non-dispatchable renewable power generation. The intermittent nature of renewable resources and their non-dispatchability substantially limit the ability of electric power generation of adapting to the fluctuating demand. Smart grid technologies and demand response programs are proposed as a technical solution to make the electric power demand more flexible and able to adapt to power generation. Residential demand response programs offer different incentives and benefits to consumers in response to their flexibility in the timing of their electricity consumption. Understanding interactions between new and existing energy technologies, and policy impacts therein, is key to driving sustainable energy use and economic growth. Comprehensive and accurate models of the next-generation power system allow for understanding the effects of new energy technologies on the power system infrastructure, and can be used to guide policy, technology, and economic decisions. This

  19. Air Risk Information Support Center

    Energy Technology Data Exchange (ETDEWEB)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  20. Does Immigrant Residential Crowding Reflect Hidden Homelessness?

    Directory of Open Access Journals (Sweden)

    Michael Haan

    2011-01-01

    Full Text Available Compared to the Canadian-born, immigrants are under-represented among Canada’s homeless population, when their decline in economic wellbeing is considered alongside their relative absence in homeless shelters. One way to explain this oddity, proposed in both academic and popular literature, is that immigrant communities employ unique avoidance strategies, such as within-group co-residence, to help keep co-ethnics off the streets and out of homeless shelters. In this paper I use the 2001 census of Canada to investigate the extent to which heightened levels of residential crowding might reflect “hidden homelessness”. I find mixed evidence to support this link, and, if anything, find some evidence to suggest that the link between residential crowding and hidden homelessness, if one exists, is strongest for the Canadian-born.

  1. FACTOR ANALYSIS OF MULTISTOREY RESIDENTIAL BUILDINGS ZONE

    Directory of Open Access Journals (Sweden)

    Петр Матвеевич Мазуркин

    2016-02-01

    Full Text Available According to the UN classification of 11 classes of soil cover, the first three are grass, trees and shrubs and forests. In the city they correspond to the three elements of vegetation: lawns, tree plantings (trees and shrubs. We have adopted zoning for city-building to identify statistical regularities. Map dimensions in GIS "Map 2011" Yoshkar-Ola was allocated to "residential zone" and "Area of construction of multi-storey residential buildings (cadastral 58 quart crystals". The parameters of the elements of the vegetation cover have been considered: the number of elements of different levels, area and perimeter, the absolute and relative form, and activity of vegetation. As the result, we have obtained equations of binomial rank distributions, conducted the ratings and selected the best of cadastral quarter on environmental conditions.

  2. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  3. Culture systems: air quality.

    Science.gov (United States)

    Thomas, Theodore

    2012-01-01

    Poor laboratory air quality is a known hazard to the culture of human gametes and embryos. Embryologists and chemists have employed analytical methods for identifying and measuring bulk and select air pollutants to assess the risk they pose to the embryo culture system. However, contaminant concentrations that result in gamete or embryotoxicity are poorly defined. Combating the ill effects of poor air quality requires an understanding of how toxicants can infiltrate the laboratory, the incubator, and ultimately the culture media. A further understanding of site-specific air quality can then lead to the consideration of laboratory design and management strategies that can minimize the deleterious effects that air contamination may have on early embryonic development in vitro.

  4. Residential Group Composition Among the Alyawarra

    OpenAIRE

    Denham, woodrowW W

    2014-01-01

    This is the third of three papers I have written recently that challenge and seek to supplant the presumption of closure, rigidity and simplicity in anthropological analyses of Australian Aboriginal social organization. The first dealt with generational closure in canonical Kariera and Aranda kinship models; the second dealt with societal closure, endogamy and the small-world problem; this one examines closure, rigidity and simplicity in residential group compositions. I argue that these thre...

  5. INVESTIGATION OF ELECTROMAGNETIC FIELDS IN RESIDENTIAL AREAS

    Directory of Open Access Journals (Sweden)

    Dušan MEDVEĎ

    2017-09-01

    Full Text Available This article is devoted to investigation of impact of electromagnetic fields around the electrical equipment used in a residential area and their impact on the human body. This paper was based on sets of measurements of magnetic induction B with magnetometer and on computational simulations in ANSYS for particular appliances often used in household. The results from measurements and simulations led to setting out the recommendations for practical action in the form of elimination of harmful electromagnetic radiation.

  6. DESIGN ASPECTS OF A RESIDENTIAL WIND GENERATOR

    Directory of Open Access Journals (Sweden)

    C. BRAD

    2017-03-01

    Full Text Available In this paper we present some aspects about the design of a small permanent magnet wind generator with axial magnetic flux often used in residential wind turbine. There are summarised the main steps of the magnetic and electric calculations with applications to a particular case: 0.6 kVA wind generator. The axial flux wind generator design starts with the characteristics of the rare earths permanent magnet existing on the market.

  7. Transition issues in an unbundled residential market

    International Nuclear Information System (INIS)

    Brett, J.D.

    1996-01-01

    Aspects of an unbundled residential gas market were discussed, among them (1) the role of a local distribution company (LDC), (2) the context and the issues, (3) the customers'needs and desires, (4) long term planning responsibility, (5) consumer protection and dealing with abuses, (6) the obligation to serve, (7) the bad credit risk customer, (8) billing, credit and collection, and (9) metering and CIS

  8. Comprehensive areal model of residential heating demands

    Energy Technology Data Exchange (ETDEWEB)

    Tessmer, R.G. Jr.

    1978-01-01

    Data sources and methodology for modeling annual residential heating demands are described. A small areal basis is chosen, census tract or minor civil division, to permit estimation of demand densities and economic evaluation of community district heating systems. The demand model is specified for the entire nation in order to provide general applicability and to permit validation with other published fuel consumption estimates for 1970.

  9. Development Of Economic Techniques For Residential Thermography

    Science.gov (United States)

    Allen, Lee R.; Allen, Sharon

    1983-03-01

    Infrared thermography has proven to be a valuable tool in the detection of heat loss in both commercial and residential buildings. The field of residential thermography has needed a simple method with which to report the deficiencies found during an infrared scan. Two major obstacles hindering the cost effectiveness of residential thermography have been 1) the ability to quickly transport some high resolution imaging system equipment from job site to job site without having to totally dismount the instruments at each area, and 2) the lack of a standard form with which to report the findings of the survey to the customer. Since the industry has yet to provide us with either, we believed it necessary to develop our own. Through trial and error, we have come up with a system that makes interior residential thermography a profitable venture at a price the homeowner can afford. Insulation voids, or defects can be instantly spotted with the use of a thermal imaging system under the proper conditions. A special hand-held device was developed that enables the thermographer to carry the equipment from house to house without the need to dismantle and set up at each stop. All the necessary components are attached for a total weight of about 40 pounds. The findings are then conveyed to a form we have developed. The form is simple enough that the client without special training in thermography can understand. The client is then able to locate the problems and take corrective measures or give it to a con-tractor to do the work.

  10. Residential outage cost estimation: Hong Kong

    International Nuclear Information System (INIS)

    Woo, C.K.; Ho, T.; Shiu, A.; Cheng, Y.S.; Horowitz, I.; Wang, J.

    2014-01-01

    Hong Kong has almost perfect electricity reliability, the result of substantial investments ultimately financed by electricity consumers who may be willing to accept lower reliability in exchange for lower bills. But consumers with high outage costs are likely to reject the reliability reduction. Our ordered-logit regression analysis of the responses by 1876 households to a telephone survey conducted in June 2013 indicates that Hong Kong residents exhibit a statistically-significant preference for their existing service reliability and rate. Moreover, the average residential cost estimate for a 1-h outage is US$45 (HK$350), topping the estimates reported in 10 of the 11 studies published in the last 10 years. The policy implication is that absent additional compelling evidence, Hong Kong should not reduce its service reliability. - Highlights: • Use a contingent valuation survey to obtain residential preferences for reliability. • Use an ordered logit analysis to estimate Hong Kong's residential outage costs. • Find high outage cost estimates that imply high reliability requirements. • Conclude that sans new evidence, Hong Kong should not reduce its reliability

  11. Modeling future demand for energy resources: A study of residential electricity usage in Thailand

    Science.gov (United States)

    Nilagupta, Prapassara

    1999-12-01

    Thailand has a critical need for effective long-term energy planning because of the country's rapidly increasing energy consumption. In this study, the demand for electricity by the residential sector is modeled using a framework that provides detailed estimates of the timing and spatial distribution of changes in energy demand. A population model was developed based on the Cohort-Component method to provide estimates of population by age, sex and urban/non-urban residency in each province. A residential electricity end user model was developed to estimate future electricity usage in urban and non-urban households of the seventy-six provinces in Thailand during the period 1999--2019. Key variables in this model include population, the number of households, family household size, and characteristics of eleven types of electric household appliance such as usage intensity, input power, and saturation rate. The methodology employed in this study is a trending method which utilizes expert opinion to estimate future variables based on a percentage change from the most current value. This study shows that from 1994 to 2019 Thailand will experience an increase in population from 55.4 to 83.6 million. Large percentage population increases will take place in Bangkok, Nonthaburi, Samut Prakarn, Nakhon Pathom and Chonburi. At a national level, the residential electricity consumption will increase from approximately 19,000 to 8 1,000 GWh annually. Consumption in non-urban households will be larger than in urban households, with respective annual increases of 8.0% and 6.2% in 2019. The percent increase of the average annual electricity consumption will be four times the average annual percent population increase. Increased electricity demand is largely a function of increased population and increased demand for high-energy appliances such as air conditioners. In 1994, air conditioning was responsible for xx% of total residential electricity demand. This study estimates that in

  12. Energy requirements of a multi-sensor based demand control ventilation system in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Chul Seong, Nam; Min Hong, Sung; Won Yoon, Dong [Kyoungwon University, Seoul (Korea, Republic of); Jun Moon, Hyeun [Dankook University, Yongin (Korea, Republic of); Augenbroe, Godfried [Georgia Institute of Technology, Atlanta (United States)

    2010-07-01

    Nowadays, people spend most of their time indoors. Therefore indoor air quality is of high importance and the building regulation in Korea was revised to apply 0.7 air change rate in residential apartment housing. However residents do not often operate mechanical ventilation systems mainly due to their utility cost. The aim of this paper is to present a demand control ventilation (DCV) system which implements ventilation strategies to meet the ventilation requirements. An evaluation was conducted on both conventional ventilation and sensor based DCV systems to compare their energy requirements. The study showed that the use of the DCV system results in a better indoor air quality and a lower energy consumption than conventional ventilation. This paper highlighted that the Korean ventilation regulation is not enough to control the CO2 concentration and that the use of the sensor-based DCV would result in a healthier and more comfortable indoor environment.

  13. The Airborne Transmission of Infection Between Flats in High-rise Residential Buildings

    DEFF Research Database (Denmark)

    Gao, N.P.; Niu, J. L.; Perino, M.

    2008-01-01

    Airborne transmission of infectious respiratory diseases in indoor environments has drawn our attention for decades, and this issue is revitalized with the outbreak of severe acute respiratory syndrome (SARS). One of the concerns is that there may be multiple transmission routes across households....... High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control....... in high-rise residential buildings, one of which is the natural ventilative airflow through open windows between flats, caused by buoyancy effects. Our early on-site measurement using tracer gases confirmed qualitatively and quantitatively that the re-entry of the exhaust-polluted air from the window...

  14. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  15. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  16. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, dust, pollen and ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, ...

  17. Nanostructured Catalytic Reactors for Air Purification, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I project proposes the development of lightweight compact nanostructured catalytic reactors for air purification from toxic gaseous organic...

  18. Nanostructured Catalytic Reactors for Air Purification, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II project proposes the development of lightweight compact nanostructured catalytic reactors for air purification from toxic gaseous organic...

  19. A low-cost-solar liquid desiccant system for residential cooling

    Science.gov (United States)

    Ware, Joel D., III

    The use of liquid desiccants for dehumidification of heating, ventilation, and air conditioning (HVAC) process air is becoming a more promising concept as the drive for energy conservation continues to grow. Recently, liquid desiccant systems have been implemented on the commercial level in conjunction with evaporative coolers and have recorded energy savings upwards of 50%. The aim of this research is to test the potential liquid desiccant systems have on the residential level when paired with a conventional vapor compression cycle and to construct a system that would overcome some of its barriers to the residential market. A complete low-cost-solar liquid desiccant system was designed, constructed, and tested in the Off-Grid Zero Emissions Building (OGZEB) at the Florida State University. Key design characteristics include turbulent process air flow through the conditioner and airside heating in the regenerator. The system was tested in the two following ways: (1) for the energy savings while maintaining a constant temperature over a twenty four hour period and (2) for the energy savings over a single cooling cycle. The liquid desiccant system achieved a maximum energy savings of 38% over a complete day and 52% over a single cooling cycle. It was projected that the system has the potential to save 1064 kWh over the course of a year. When combined with a renewable source of heat for regeneration, liquid desiccant systems become very cost effective. The levelized cost of energy for the combination of the liquid desiccant system and solar thermal collectors was calculated to be 7.06 C/kWh with a payback period of 4.4 years. This research provides evidence of the technology's potential on the residential sector and suggests ways for it to become competitive in the market.

  20. Emissions from residential energy use dominate exposure to ambient fine particulate matter in India

    Science.gov (United States)

    Conibear, L.; Butt, E. W.; Knote, C. J.; Arnold, S.; Spracklen, D. V.

    2017-12-01

    Exposure to ambient particulate matter of less than 2.5 µm in diameter (PM2.5) is a leading cause of disease burden in India. Information on the source contributions to the burden of disease attributable to ambient PM2.5 exposure is critical to support the national and sub-national control of air pollution. Previous studies analysing the contributions of different emission sectors to disease burden in India have been limited by coarse model resolutions and a lack of extensive PM2.5 observations before 2016. We use a regional numerical weather prediction model online-coupled with chemistry, evaluated against extensive surface observations, to make the first high resolution study of the contributions of seven emission sectors to the disease burden associated with ambient PM2.5 exposure in India. We find that residential energy use is the dominant contributing emission sector. Removing air pollution emissions from residential energy use would reduce population-weighted annual mean ambient PM2.5 concentrations by 52%, reducing the number of premature mortalities caused by exposure to ambient PM2.5 by 26%, equivalent to 268,000 (95% uncertainty interval (95UI): 167,000-360,000) lives every year. The smaller fractional reduction in mortality burden is due to the non-linear exposure-response relationship at the high PM2.5 concentrations observed across India and consequently large reductions in emissions are required to reduce the health burden from ambient PM2.5 exposure in India. Keywords: ambient air quality, India, residential energy use, health impact, particulate matter, WRF-Chem