WorldWideScience

Sample records for repetition rate view

  1. High-repetition-rate hydrogen chamber: Preliminary studies

    International Nuclear Information System (INIS)

    1967-01-01

    This report is a conclusion to the tests realised with an experimental bubbles chamber in view to study the possibilities to increase the repetition rate. The more important parameters (the evolution of the bubbles, the expansion system) are considered in a theoretical way. Then the hardware is described. To end, experimental results are compared with the first evaluations. The calculations and the experimentation are against an oscillation system for the expansion. A system with a locking is to he considered. (authors) [fr

  2. Solid state pump lasers with high power and high repetition rate

    International Nuclear Information System (INIS)

    Oba, Masaki; Kato, Masaaki; Arisawa, Takashi

    1995-01-01

    We built a laser diode pumped solid state green laser (LDPSSGL) rated at high repetition rate. Two laser heads are placed in one cavity with a rotator in between to design to avoid thermal lensing and thermal birefringence effect. Although average green laser power higher than 10 W was obtained at 1 kHz repetition rate with pulse width of 20-30 nsec, the beam quality was so much deteriorated that energy efficiency was as low as 2 %. Learning from this experience that high power oscillator causes a lot of thermal distortion not only in the laser rod but also in the Q-switch device, we proceeded to built a oscillator/amplifier system. A low power oscillator has a slab type crystal in the cavity. As a result spatial distribution of laser power was extremely improved. As we expect that the high repetition rate solid state laser should be CW operated Q-switch type laser from the view point of lifetime of diode lasers, a conventional arc lamp pumped CW Q-switch green YAG laser of which the repetition rate is changeable from 1 kHz to 5 kHz and the pulse width is 250-570 nsec was also tested to obtain pumping characteristics of a dye laser as a function of power, pulse width etc., and dye laser pulse width of 100-130 nsec were obtained. (author)

  3. High-repetition-rate hydrogen chamber: Preliminary studies; Chambre a hydrogene a haut taux de repetition: Etudes preliminaires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1967-01-01

    This report is a conclusion to the tests realised with an experimental bubbles chamber in view to study the possibilities to increase the repetition rate. The more important parameters (the evolution of the bubbles, the expansion system) are considered in a theoretical way. Then the hardware is described. To end, experimental results are compared with the first evaluations. The calculations and the experimentation are against an oscillation system for the expansion. A system with a locking is to he considered. (authors) [French] Ce rapport est une conclusion aux essais realises avec une chambre a bulles experimentale en vue d'etudier les possibilites d'accroitre les taux de repetition. Les parametres les plus importants (evolution des bulles, mecanique de la detente) sont etudies par voie theorique. Puis l'appareillage est decrit. Enfin, les resultats experimentaux sont compares aux evaluations donnees au debut. Ces calculs et cette experimentation ne sont pas en faveur d'un systeme oscillant pour la detente et il faut envisager un systeme avec verrouillage. (auteurs)

  4. High-repetition-rate short-pulse gas discharge.

    Science.gov (United States)

    Tulip, J; Seguin, H; Mace, P N

    1979-09-01

    A high-average-power short-pulse gas discharge is described. This consists of a volume-preionized transverse discharge of the type used in gas lasers driven by a Blumlein energy storage circuit. The Blumlein circuit is fabricated from coaxial cable, is pulse-charged from a high-repetition-rate Marx-bank generator, and is switched by a high-repetition-rate segmented rail gap. The operation of this discharge under conditions typical of rare-gas halide lasers is described. A maximum of 900 pps was obtained, giving a power flow into the discharge of 30 kW.

  5. Properties of water surface discharge at different pulse repetition rates

    International Nuclear Information System (INIS)

    Ruma,; Yoshihara, K.; Hosseini, S. H. R.; Sakugawa, T.; Akiyama, H.; Akiyama, M.; Lukeš, P.

    2014-01-01

    The properties of water surface discharge plasma for variety of pulse repetition rates are investigated. A magnetic pulse compression (MPC) pulsed power modulator able to deliver pulse repetition rates up to 1000 Hz, with 0.5 J per pulse energy output at 25 kV, was used as the pulsed power source. Positive pulse with a point-to-plane electrode configuration was used for the experiments. The concentration and production yield of hydrogen peroxide (H 2 O 2 ) were quantitatively measured and orange II organic dye was treated, to evaluate the chemical properties of the discharge reactor. Experimental results show that the physical and chemical properties of water surface discharge are not influenced by pulse repetition rate, very different from those observed for under water discharge. The production yield of H 2 O 2 and degradation rate per pulse of the dye did not significantly vary at different pulse repetition rates under a constant discharge mode on water surface. In addition, the solution temperature, pH, and conductivity for both water surface and underwater discharge reactors were measured to compare their plasma properties for different pulse repetition rates. The results confirm that surface discharge can be employed at high pulse repetition rates as a reliable and advantageous method for industrial and environmental decontamination applications.

  6. Generation of µW level plateau harmonics at high repetition rate.

    Science.gov (United States)

    Hädrich, S; Krebs, M; Rothhardt, J; Carstens, H; Demmler, S; Limpert, J; Tünnermann, A

    2011-09-26

    The process of high harmonic generation allows for coherent transfer of infrared laser light to the extreme ultraviolet spectral range opening a variety of applications. The low conversion efficiency of this process calls for optimization or higher repetition rate intense ultrashort pulse lasers. Here we present state-of-the-art fiber laser systems for the generation of high harmonics up to 1 MHz repetition rate. We perform measurements of the average power with a calibrated spectrometer and achieved µW harmonics between 45 nm and 61 nm (H23-H17) at a repetition rate of 50 kHz. Additionally, we show the potential for few-cycle pulses at high average power and repetition rate that may enable water-window harmonics at unprecedented repetition rate. © 2011 Optical Society of America

  7. Pulse repetition rate multiplication by Talbot effect in a coaxial fiber

    Science.gov (United States)

    Dhingra, Nikhil; Saxena, Geetika Jain; Anand, Jyoti; Sharma, Enakshi K.

    2018-03-01

    We use a coaxial fiber, which is a cylindrical coupled waveguide structure consisting of two concentric cores, the inner rod and an outer ring core as a first order dispersive media to achieve temporal Talbot effect for pulse repetition rate multiplication (PRRM) in high bit rate optical fiber communication. It is observed that for an input Gaussian pulse train with pulse width, 2τ0=1ps at a repetition rate of 40 Gbps (repetition period, T=25ps), an output repetition rate of 640 Gbps can be achieved without significant distortion at a length of 40.92 m.

  8. A copper bromide vapour laser with a high pulse repetition rate

    International Nuclear Information System (INIS)

    Shiyanov, D V; Evtushenko, Gennadii S; Sukhanov, V B; Fedorov, V F

    2002-01-01

    The results of an experimental study of a copper bromide vapour laser with a discharge-channel diameter above 2.5 cm and a high pump-pulse repetition rate are presented. A TGU1-1000/25 high-power tacitron used as a switch made it possible to obtain for the first time a fairly high output radiation power for pump-pulse repetition rates exceeding 200 kHz. At a maximum pump-pulse repetition rate of 250 kHz achieved in a laser tube 2.6 cm in diameter and 76 cm long, the output power was 1.5 W. The output powers of 3 and 10.5 W were reached for pump-pulse repetition rates of 200 and 100 kHz, respectively. These characteristics were obtained without circulating a buffer gas and (or) low-concentration active impurities through the active volume. (active media. lasers)

  9. High repetition rate intense ion beam source

    International Nuclear Information System (INIS)

    Hammer, D.A.; Glidden, S.C.; Noonan, B.

    1992-01-01

    This final report describes a ≤ 150kV, 40kA, 100ns high repetition rate pulsed power system and intense ion beam source which is now in operation at Cornell University. Operation of the Magnetically-controlled Anode Plasma (MAP) ion diode at > 100Hz (burst mode for up to 10 pulse bursts) provides an initial look at repetition rate limitations of both the ion diode and beam diagnostics. The pulsed power systems are capable of ≥ 1kHz operation (up to 10 pulse bursts), but ion diode operation was limited to ∼100Hz because of diagnostic limitations. By varying MAP diode operating parameters, ion beams can be extracted at a few 10s of keV or at up to 150keV, the corresponding accelerating gap impedance ranging from about 1Ω to about 10Ω. The ability to make hundreds of test pulses per day at an average repetition rate of about 2 pulses per minute permits statistical analysis of diode operation as a function of various parameters. Most diode components have now survived more than 10 4 pulses, and the design and construction of the various pulsed power components of the MAP diode which have enabled us to reach this point are discussed. A high speed data acquisition system and companion analysis software capable of acquiring pulse data at 1ms intervals (in bursts of up to 10 pulses) and processing it in ≤ min is described

  10. Iodine laser of high efficiency and fast repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Hohla, K; Witte, K J

    1976-07-01

    The scaling laws of an iodine laser of high efficiency and fast repetition rate are reported. The laser is pumped with a new kind of low pressure Hg-UV-lamps which convert 32% of the electrical input in UV-light in the absorption band of the iodine laser and which can be fired up to 100 Hz. Details of a 10 kJ/1 nsec system as dimensions, energy density, repetition rate, flow velocity, gas composition and gas pressure and the overall efficiency are given which is expected to be about 2%.

  11. Temporal dynamics of high repetition rate pulsed single longitudinal ...

    Indian Academy of Sciences (India)

    ing (GIG) cavity, single-mode dye laser pumped by high repetition rate ... in a high loss cavity, a detailed theoretical study and optimization of cavity ..... rate for high conversion efficiency and longer pulse width of the single-mode dye laser.

  12. Optimization of graffiti removal on natural stone by means of high repetition rate UV laser

    International Nuclear Information System (INIS)

    Fiorucci, M.P.; López, A.J.; Ramil, A.; Pozo, S.; Rivas, T.

    2013-01-01

    The use of laser for graffiti removal is a promising alternative to conventional cleaning methods, though irradiation parameters must be carefully selected in order to achieve the effective cleaning without damaging the substrate, especially when referring to natural stone. From a practical point of view, once a safe working window is selected, it is necessary to determine the irradiation conditions to remove large paint areas, with minimal time consumption. The aim of this paper is to present a systematic procedure to select the optimum parameters for graffiti removal by means of the 3rd harmonic of a high repetition rate nanosecond Nd:YVO 4 laser. Ablation thresholds of four spray paint colors were determined and the effect of pulse repetition frequency, beam diameter and line scan separation was analyzed, obtaining a set of values which optimize the ablation process.

  13. Optimization of graffiti removal on natural stone by means of high repetition rate UV laser

    Energy Technology Data Exchange (ETDEWEB)

    Fiorucci, M.P., E-mail: m.p.fiorucci@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain); López, A.J., E-mail: ana.xesus.lopez@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Ramil, A., E-mail: alberto.ramil@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Pozo, S., E-mail: ipozo@uvigo.es [Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain); Rivas, T., E-mail: trivas@uvigo.es [Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain)

    2013-08-01

    The use of laser for graffiti removal is a promising alternative to conventional cleaning methods, though irradiation parameters must be carefully selected in order to achieve the effective cleaning without damaging the substrate, especially when referring to natural stone. From a practical point of view, once a safe working window is selected, it is necessary to determine the irradiation conditions to remove large paint areas, with minimal time consumption. The aim of this paper is to present a systematic procedure to select the optimum parameters for graffiti removal by means of the 3rd harmonic of a high repetition rate nanosecond Nd:YVO{sub 4} laser. Ablation thresholds of four spray paint colors were determined and the effect of pulse repetition frequency, beam diameter and line scan separation was analyzed, obtaining a set of values which optimize the ablation process.

  14. Testing of super conducting low-beta 704 Mhz cavities at 50 Hz pulse repetition rate in view of SPL- first results

    CERN Document Server

    Höfle, W; Lollierou, J; Valuch, D; Chel, S; Devanz, G; Desmons, M; Piquet, O; Paparella, R; Pierini, P

    2010-01-01

    In the framework of the preparatory phase for the luminosity upgrade of the LHC (SLHC-PP ) it is foreseen to characterize two superconducting RF cavities and demonstrate compliance of the required SPL field stability in amplitude and phase using a prototype LLRF system. We report on the preparation for testing of two superconducting low-beta cavities at 50 Hz pulse repetition rate including the setting-up of the low level RF control system to evaluate the performance of the piezo-tuning system and cavity field stability in amplitude and phase. Results from tests with 50 Hz pulse repetition rate are presented. Simulations of the RF system will be used to predict the necessary specifications for power and bandwidth to control the cavity field and derive specifications for the RF system and its control. Exemplary results of the simulation are presented.

  15. Design and Development of High-Repetition-Rate Satellite Laser Ranging System

    Science.gov (United States)

    Choi, Eun-Jung; Bang, Seong-Cheol; Sung, Ki-Pyoung; Lim, Hyung-Chul; Jung, Chan-Gyu; Kim, In-Yeung; Choi, Jae-Seung

    2015-09-01

    The Accurate Ranging System for Geodetic Observation ? Mobile (ARGO-M) was successfully developed as the first Korean mobile Satellite Laser Ranging (SLR) system in 2012, and has joined in the International Laser Ranging Service (ILRS) tracking network, DAEdeoK (DAEK) station. The DAEK SLR station was approved as a validated station in April 2014, through the ILRS station ¡°data validation¡± process. The ARGO-M system is designed to enable 2 kHz laser ranging with millimeter-level precision for geodetic, remote sensing, navigation, and experimental satellites equipped with Laser Retroreflector Arrays (LRAs). In this paper, we present the design and development of a next generation high-repetition-rate SLR system for ARGO-M. The laser ranging rate up to 10 kHz is becoming an important issue in the SLR community to improve ranging precision. To implement high-repetition-rate SLR system, the High-repetition-rate SLR operation system (HSLR-10) was designed and developed using ARGO-M Range Gate Generator (A-RGG), so as to enable laser ranging from 50 Hz to 10 kHz. HSLR-10 includes both hardware controlling software and data post-processing software. This paper shows the design and development of key technologies of high-repetition-rate SLR system. The developed system was tested successfully at DAEK station and then moved to Sejong station, a new Korean SLR station, on July 1, 2015. HSLR-10 will begin normal operations at Sejong station in the near future.

  16. Electrode patterning of ITO thin films by high repetition rate fiber laser

    International Nuclear Information System (INIS)

    Lin, H.K.; Hsu, W.C.

    2014-01-01

    Indium tin oxide (ITO) thin films are deposited on glass substrates using a radio frequency magnetron sputtering system. As-deposited ITO thin film was 100 nm in thickness and a transmittance of ITO film on glass substrate was 79% at 550 nm. Conductive electrodes are then patterned on the ITO films using a high repetition rate fiber laser system followed by a wet chemical etching process. The electrical, optical and structural properties of the patterned samples are evaluated by means of a four-point probe technique, spectrophotometer, X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM). The results show that the samples annealed with a pulse repetition rate of 150 kHz or 400 kHz have a low sheet resistivity of 21 Ω/□ and a high optical transmittance of 90%. In addition, it is shown that a higher pulse repetition rate reduces both the residual stress and the surface roughness of the patterned specimens. Therefore, the present results suggest that a pulse repetition rate of 400 kHz represents the optimal processing condition for the patterning of crack-free ITO-coated glass substrates with good electrical and optical properties.

  17. Electrode patterning of ITO thin films by high repetition rate fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Lin, H.K., E-mail: HKLin@mail.npust.edu.tw; Hsu, W.C.

    2014-07-01

    Indium tin oxide (ITO) thin films are deposited on glass substrates using a radio frequency magnetron sputtering system. As-deposited ITO thin film was 100 nm in thickness and a transmittance of ITO film on glass substrate was 79% at 550 nm. Conductive electrodes are then patterned on the ITO films using a high repetition rate fiber laser system followed by a wet chemical etching process. The electrical, optical and structural properties of the patterned samples are evaluated by means of a four-point probe technique, spectrophotometer, X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM). The results show that the samples annealed with a pulse repetition rate of 150 kHz or 400 kHz have a low sheet resistivity of 21 Ω/□ and a high optical transmittance of 90%. In addition, it is shown that a higher pulse repetition rate reduces both the residual stress and the surface roughness of the patterned specimens. Therefore, the present results suggest that a pulse repetition rate of 400 kHz represents the optimal processing condition for the patterning of crack-free ITO-coated glass substrates with good electrical and optical properties.

  18. Femtosecond Ti:sapphire cryogenic amplifier with high gain and MHz repetition rate

    DEFF Research Database (Denmark)

    Dantan, Aurelien Romain; Laurat, Julien; Ourjoumtsev, Alexei

    2007-01-01

    We demonstrate high gain amplification of 160-femtosecond pulses in a compact double-pass cryogenic Ti:sapphire amplifier. The setup involves a negative GVD mirrors recompression stage, and operates with a repetition rate between 0.2 and 4 MHz with a continuous pump laser. Amplification factors a...... as high as 17 and 320 nJ Fourier-limited pulses are obtained at a 800 kHz repetition rate....

  19. High repetition rate burst-mode spark gap

    International Nuclear Information System (INIS)

    Faltens, A.; Reginato, L.; Hester, R.; Chesterman, A.; Cook, E.; Yokota, T.; Dexter, W.

    1978-01-01

    Results are presented on the design and testing of a pressurized gas blown spark gap switch capable of high repetition rates in a burst mode of operation. The switch parameters which have been achieved are as follows: 220-kV, 42-kA, a five pulse burst at 1-kHz, 12-ns risetime, 2-ns jitter at a pulse width of 50-ns

  20. Effects of picosecond laser repetition rate on ablation of Cr12MoV cold work mold steel

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Baoye; Deng, Leimin; Liu, Peng; Zhang, Fei; Duan, Jun, E-mail: duans@hust.edu.cn; Zeng, Xiaoyan

    2017-07-01

    In this paper, the effects of pulse repetition rate on ablation efficiency and quality of Cr12MoV cold work mold steel have been studied using a picosecond (ps) pulse Nd:YVO{sub 4} laser system at λ= 1064 nm. The experimental results of area ablation on target surface reveal that laser repetition rate plays a significant role in controlling ablation efficiency and quality. Increasing the laser repetition rate, while keeping a constant mean power improves the ablation efficiency and quality. For each laser mean power, there is an optimal repetition rate to achieve a higher laser ablation efficiency with low surface roughness. A high ablation efficiency of 42.29, 44.11 and 47.52 μm{sup 3}/mJ, with surface roughness of 0.476, 0.463 and 0.706 μm could be achieved at laser repetition rate of 10 MHz, for laser mean power of 15, 17 and 19 W, respectively. Scanning electron microcopy images revels that the surface morphology evolves from rough with numerous craters, to flat without pores when we increased the laser repetition rate. The effects of laser repetition rate on the heat accumulation, plasma shield and ablation threshold were analyzed by numerical simulation, spectral analysis and multi-laser shot, respectively. The synergetic effects of laser repetition rate on laser ablation rate and machining quality were analyzed and discussed systemically in this paper.

  1. Design of a low emittance and high repetition rate S-band photoinjector

    Science.gov (United States)

    Han, Jang-Hui

    2014-09-01

    As an electron beam injector of X-ray free-electron lasers (FELs), photoinjectors have been developed for the past few decades. Such an injector starting with a photocathode RF gun provides high brightness beams and therefore it is being adopted as an injector of X-ray FELs. In this paper we show how to improve photoinjector performance in terms of emittance and repetition rates by means of injector components optimization, especially with the gun. Transverse emittance at the end of an injector is reduced by optimizing the gun design, gun solenoid position, and accelerating section position. The repetition rate of an injector mainly depends on the gun. It is discussed that a repetition rate of 1 kHz at a normal-conducting S-band photoinjector is feasible by adopting a coaxial RF coupler and improving cooling-water channels surrounding the gun.

  2. Closed cycle high-repetition-rate pulsed HF laser

    Science.gov (United States)

    Harris, Michael R.; Morris, A. V.; Gorton, Eric K.

    1997-04-01

    The design and performance of a closed cycle high repetition rate HF laser is described. A short pulse, glow discharge is formed in a 10 SF6:1 H2 gas mixture at a total pressure of approximately 110 torr within a 15 by 0.5 by 0.5 cm3 volume. Transverse, recirculated gas flow adequate to enable repetitive operation up to 3 kHz is imposed by a centrifugal fan. The fan also forces the gas through a scrubber cell to eliminate ground state HF from the gas stream. An automated gas make-up system replenishes spent gas removed by the scrubber. Typical mean laser output powers up to 3 W can be maintained for extended periods of operation.

  3. Scaling of black silicon processing time by high repetition rate femtosecond lasers

    Directory of Open Access Journals (Sweden)

    Nava Giorgio

    2013-11-01

    Full Text Available Surface texturing of silicon substrates is performed by femtosecond laser irradiation at high repetition rates. Various fabrication parameters are optimized in order to achieve very high absorptance in the visible region from the micro-structured silicon wafer as compared to the unstructured one. A 70-fold reduction of the processing time is demonstrated by increasing the laser repetition rate from 1 kHz to 200 kHz. Further scaling up to 1 MHz can be foreseen.

  4. Comparison on different repetition rate locking methods in Er-doped fiber laser

    Science.gov (United States)

    Yang, Kangwen; Zhao, Peng; Luo, Jiang; Huang, Kun; Hao, Qiang; Zeng, Heping

    2018-05-01

    We demonstrate a systematic comparative research on the all-optical, mechanical and opto-mechanical repetition rate control methods in an Er-doped fiber laser. A piece of Yb-doped fiber, a piezoelectric transducer and an electronic polarization controller are simultaneously added in the laser cavity as different cavity length modulators. By measuring the cavity length tuning ranges, the output power fluctuations, the temporal and frequency repetition rate stability, we show that all-optical method introduces the minimal disturbances under current experimental condition.

  5. Novel fast-neutron activation counter for high repetition rate measurements

    International Nuclear Information System (INIS)

    Mahmood, S.; Springham, S. V.; Zhang, T.; Rawat, R. S.; Tan, T. L.; Krishnan, M.; Beg, F. N.; Lee, S.; Schmidt, H.; Lee, P.

    2006-01-01

    A fast-neutron beryllium activation counter has been constructed for neutron measurements on a high repetition rate deuterium plasma focus. Beryllium activation is especially suitable for measurements of DD neutron yields. The cross section for the relevant reaction, 9 Be(n,α) 6 He, results in a maximum sensitivity at the characteristic energy of the DD neutrons (∼2.5 MeV) and practically no sensitivity to neutrons with energies 6 He enabled the shot-to-shot neutron yield from the plasma focus to be measured for repetition rates from 0.2 to 3 Hz (and for a range of deuterium gas pressures). With careful analysis, the shot-to-shot yield can be measured up to a maximum repetition rate of 3 Hz, beyond which the pileup of counts from the previous shots reduces the accuracy of the measurements to an unacceptable level. This new beryllium activation counter has been cross-checked against an indium activation counter to obtain absolute neutron yields. At a charging voltage of 12.5 kV (bank energy of 2.2 kJ), the average neutron yield was found to be (7.9±0.7)x10 7 per shot (standard deviation of 4x10 7 ). It was found that activation of the plasma focus construction materials (especially aluminum) must be taken into account

  6. Generation of plasma X-ray sources via high repetition rate femtosecond laser pulses

    Science.gov (United States)

    Baguckis, Artūras; Plukis, Artūras; Reklaitis, Jonas; Remeikis, Vidmantas; Giniūnas, Linas; Vengris, Mikas

    2017-12-01

    In this study, we present the development and characterization of Cu plasma X-ray source driven by 20 W average power high repetition rate femtosecond laser in ambient atmosphere environment. The peak Cu- Kα photon flux of 2.3 × 109 photons/s into full solid angle is demonstrated (with a process conversion efficiency of 10-7), using pulses with peak intensity of 4.65 × 1014 W/cm2. Such Cu- Kα flux is significantly larger than others found in comparable experiments, performed in air environment. The effects of resonance plasma absorption process, when optimized, are shown to increase measured flux by the factor of 2-3. The relationship between X-ray photon flux and plasma-driving pulse repetition rate is quasi-linear, suggesting that fluxes could further be increased to 1010 photons/s using even higher average powers of driving radiation. These results suggest that to fully utilize the potential of high repetition rate laser sources, novel target material delivery systems (for example, jet-based ones) are required. On the other hand, this study demonstrates that high energy lasers currently used for plasma X-ray sources can be conveniently and efficiently replaced by high average power and repetition rate laser radiation, as a way to increase the brightness of the generated X-rays.

  7. Patterning crystalline indium tin oxide by high repetition rate femtosecond laser-induced crystallization

    International Nuclear Information System (INIS)

    Cheng, Chung-Wei; Lin, Cen-Ying; Shen, Wei-Chih; Lee, Yi-Ju; Chen, Jenq-Shyong

    2010-01-01

    A method is proposed for patterning crystalline indium tin oxide (c-ITO) patterns on amorphous ITO (a-ITO) thin films by femtosecond laser irradiation at 80 MHz repetition rate followed by chemical etching. In the proposed approach, the a-ITO film is transformed into a c-ITO film over a predetermined area via the heat accumulation energy supplied by the high repetition rate laser beam, and the unirradiated a-ITO film is then removed using an acidic etchant solution. The fabricated c-ITO patterns are observed using scanning electron microscopy and cross-sectional transmission electron microscopy. The crystalline, optical, electrical properties were measured by X-ray diffraction, spectrophotometer, and four point probe station, respectively. The experimental results show that a high repetition rate reduces thermal shock and yields a corresponding improvement in the surface properties of the c-ITO patterns.

  8. A high-repetition rate LWFA for studies of laser propagation and electron generation

    Science.gov (United States)

    He, Zhaohan; Easter, James; Hou, Bixue; Krushelnick, Karl; Nees, John; Thomas, Alec

    2010-11-01

    Advances in ultrafast optics today have enabled laser systems to deliver ever shorter and more intense pulses. When focused, such laser pulses can easily exceed relativistic intensities where the wakefield created by the strong laser electric field can be used to accelerate electrons. Laser wakefield acceleration of electrons holds promise for future compact electron accelerators or drivers of other radiation sources in many scientific, medical and engineering applications. We present experimental studies of laser wakefield acceleration using the λ-cubed laser at the University of Michigan -- a table-top high-power laser system operating at 500 Hz repetition rate. The high repetition rate allows statistical studies of laser propagation and electron acceleration which are not accessible with typical sub-0.1 Hz repetition rate systems. In addition, we compare the experiments with particle-in-cell simulations using the code OSIRIS.

  9. High energy high repetition-rate thin-disk amplifier for OPCPA pumping

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael

    2013-08-15

    The development of a pump laser system for a high power and high repetition rate optical parametric chirped-pulse amplification (OPCPA) is presented in this thesis. The OPCPA system requires pump pulse energies in the range of tens of millijoules at high repetition rates with sub-picosecond pulse durations. This can be achieved to some extend with Innoslab amplifier technology. However, scaling to higher pulse energies at high repetition rates may be problematic. With the thin-disk amplifier presented in this thesis, output energies of 140 mJ at 100 kHz repetition rate could be achieved in burst-mode operation, which is a world record for this type of laser amplifier. Due to its material and spectral properties, ytterbium doped YAG (Yb:YAG) is used as a gain medium for the high power amplifier stages. The low quantum defect and the comparatively large emission bandwidth makes this material the choice for high power operation and sub-picosecond compressed pulse durations. The output beam profile as well as the shape of the output bursts is ideal to pump an OPCPA system. An OPCPA output energy in the millijoule range with repetition rates of 100 kHz to 1 MHz is needed to generate seed pulses for the FEL and for the application as pump-probe laser at the FEL facility. Since the development of this laser system needs to meet requirements set by the Free-Electron Laser in Hamburg (FLASH), the amplifier is conceived for burst-mode operation. The main requirement is a high intra-burst pulse repetition rate of more than 100 kHz and a uniform pulse train (burst) with equal properties for every pulse. The burst-mode is an operation mode where the laser never reaches a lasing equilibrium, which means that the behavior of the amplifier is similar to a switch-on of the laser system for every burst. This makes the development of the amplifier system difficult. Therefore, an analytical model has been developed to study the amplification process during the burst. This includes the

  10. High energy high repetition-rate thin-disk amplifier for OPCPA pumping

    International Nuclear Information System (INIS)

    Schulz, Michael

    2013-08-01

    The development of a pump laser system for a high power and high repetition rate optical parametric chirped-pulse amplification (OPCPA) is presented in this thesis. The OPCPA system requires pump pulse energies in the range of tens of millijoules at high repetition rates with sub-picosecond pulse durations. This can be achieved to some extend with Innoslab amplifier technology. However, scaling to higher pulse energies at high repetition rates may be problematic. With the thin-disk amplifier presented in this thesis, output energies of 140 mJ at 100 kHz repetition rate could be achieved in burst-mode operation, which is a world record for this type of laser amplifier. Due to its material and spectral properties, ytterbium doped YAG (Yb:YAG) is used as a gain medium for the high power amplifier stages. The low quantum defect and the comparatively large emission bandwidth makes this material the choice for high power operation and sub-picosecond compressed pulse durations. The output beam profile as well as the shape of the output bursts is ideal to pump an OPCPA system. An OPCPA output energy in the millijoule range with repetition rates of 100 kHz to 1 MHz is needed to generate seed pulses for the FEL and for the application as pump-probe laser at the FEL facility. Since the development of this laser system needs to meet requirements set by the Free-Electron Laser in Hamburg (FLASH), the amplifier is conceived for burst-mode operation. The main requirement is a high intra-burst pulse repetition rate of more than 100 kHz and a uniform pulse train (burst) with equal properties for every pulse. The burst-mode is an operation mode where the laser never reaches a lasing equilibrium, which means that the behavior of the amplifier is similar to a switch-on of the laser system for every burst. This makes the development of the amplifier system difficult. Therefore, an analytical model has been developed to study the amplification process during the burst. This includes the

  11. Repetition rate stabilization of an erbium-doped all-fiber laser via opto-mechanical control of the intracavity group velocity

    International Nuclear Information System (INIS)

    Shen, Xuling; He, Boqu; Zhao, Jian; Liu, Yang; Bai, Dongbi; Wang, Chao; Liu, Geping; Luo, Daping; Liu, Fengjiang; Li, Wenxue; Zeng, Heping; Yang, Kangwen; Hao, Qiang

    2015-01-01

    We present a method for stabilizing the repetition rate of an erbium-doped all-fiber laser by inserting an electronic polarization controller (EPC) in the fiber laser cavity. The device exhibited good integration, low cost, and convenient operation. Such a repetition rate stabilization may facilitate an all-fiber laser comb system with high integration. The repetition rate was phase-locked to a Rb reference more than 72 h with a low feedback voltage applied to one channel of the EPC. The repetition rate was 74.6 MHz. The standard deviation and the repetition rate linewidth were 1.4 and 1.7 mHz, respectively

  12. Sustainment of spherical tokamak by means of repetitive injection of compact torus plasma

    International Nuclear Information System (INIS)

    Shimamura, Shin; Matsura, Ken; Takahashi, Tsutomu; Nogi, Yasuyuki

    2000-01-01

    Sustainment of spherical tokamak (S.T.) has been studied. A compact torus (C.T.) plasma was injected into confinement region by magnetized coaxial gun. For start-up and sustainment of large main spherical tokamak, single pulsed injection of small C.T. is not sufficient in many cases. C.T.plasma injection of high repetition rate is required. For this purpose magnetized coaxial gun was driven with high repetition rate current. The first injected C.T. plasma could start-up S.T. without other help. The repetitive C.T. injection grew and sustained the S.T. plasma. A CCD camera with fast gated image intensifier took a cross sectional view of S.T. during the repetitive C.T. injection. (author)

  13. High-power pre-chirp managed amplification of femtosecond pulses at high repetition rates

    International Nuclear Information System (INIS)

    Liu, Yang; Li, Wenxue; Zhao, Jian; Bai, Dongbi; Luo, Daping; Zeng, Heping

    2015-01-01

    Femtosecond pulses at 250 MHz repetition rate from a mode-locked fiber laser are amplified to high power in a pre-chirp managed amplifier. The experimental strategy offers a potential towards high-power ultrashort laser pulses at high repetition rates. By investigating the laser pulse evolution in the amplification processes, we show that self-similar evolution, finite gain bandwidth and mode instabilities determine pulse characteristics in different regimes. Further average power scaling is limited by the mode instabilities. Nevertheless, this laser system enables us to achieve sub-50 fs pulses with an average power of 93 W. (letter)

  14. Operation and Thermal Modeling of the ISIS H– Source from 50 to 2 Hz Repetition Rates

    CERN Document Server

    Pereira, H; Lettry, J

    2013-01-01

    CERN’s Linac4 accelerator H− ion source, currently under construction, will operate at a 2 Hz repetition rate, with pulse length of 0.5 ms and a beam current of 80 mA. Its reliability must exceed 99 % with a mandatory 3 month uninterrupted operation period. A Penning ion source is successfully operated at ISIS; at 50 Hz repetition rate it reliably provides 55 mA H− pulses of 0.25 ms duration over 1 month. The discharge plasma ignition is very sensitive to the temperatures of the discharge region, especially of its cathode. The investigation by modeling and measurement of operation parameters suitable for arc ignition and H− production at 2 Hz is of paramount importance and must be understood prior to the implementation of discharge ion sources in the Linac4 accelerator. In its original configuration, the ISIS H− source delivers beam only if the repetition rate is above 12.5 Hz, this paper describes the implementation of a temperature control of the discharge region aiming at lower repetition rate op...

  15. Probing background ionization: positive streamers with varying pulse repetition rate and with a radioactive admixture

    International Nuclear Information System (INIS)

    Nijdam, S; Van Veldhuizen, E M; Ebert, U; Wormeester, G

    2011-01-01

    Positive streamers need a source of free electrons ahead of them to propagate. A streamer can supply these electrons by itself through photo-ionization, or the electrons can be present due to external background ionization. Here we investigate the effects of background ionization on streamer propagation and morphology by changing the gas composition and the repetition rate of the voltage pulses, and by adding a small amount of radioactive 85 Kr. We find that the general morphology of a positive streamer discharge in high-purity nitrogen depends on background ionization: at lower background ionization levels the streamers branch more and have a more feather-like appearance. This is observed both when varying the repetition rate and when adding 85 Kr, though side branches are longer with the radioactive admixture. But velocities and minimal diameters of streamers are virtually independent of the background ionization level. In air, the inception cloud breaks up into streamers at a smaller radius when the repetition rate and therefore the background ionization level is higher. When measuring the effects of the pulse repetition rate and of the radioactive admixture on the discharge morphology, we found that our estimates of background ionization levels are consistent with these observations; this gives confidence in the estimates. Streamer channels generally do not follow the paths of previous discharge channels for repetition rates of up to 10 Hz. We estimate the effect of recombination and diffusion of ions and free electrons from the previous discharge and conclude that the old trail has largely disappeared at the moment of the next voltage pulse; therefore the next streamers indeed cannot follow the old trail.

  16. High-q microring resonator with narrow free spectral range for pulse repetition rate multiplication

    DEFF Research Database (Denmark)

    Pu, Minhao; Ji, Hua; Frandsen, Lars Hagedorn

    2009-01-01

    We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz.......We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz....

  17. Reduction of the beam pulse repetition rate of the Hamburg Isochronous Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Langkau, R; Schirm, N [Hamburg Univ. (F.R. Germany). 1. Inst. fuer Experimentalphysik

    1976-04-01

    A system for the reduction of the beam pulse repetition rate of the energy-variable Hamburg Isochronous Cyclotron comprising beam pulse supression in the cyclotron center and in the external beam is described.

  18. On the mechanisms governing the repetition rate of mode-locked semiconductor lasers

    DEFF Research Database (Denmark)

    Mulet, Josep; Mørk, Jesper

    2004-01-01

    We investigate the mechanisms influencing the synchronization locking range of mode-locked lasers. We find that changes in repetition rates can be accomodated through a joint interplay of dispersion and pulse shaping effects....

  19. Ultraviolet excimer laser ablation: the effect of wavelength and repetition rate on in vivo guinea pig skin

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, J.; Kibbi, A.G.; Farinelli, W.; Boll, J.; Tan, O.T.

    1987-06-01

    Multiple dermatologic conditions that are currently treated with traditional cold-knife surgery are amenable to laser therapy. The ideal surgical treatment would be precise and total removal of abnormal tissue with maximal sparing of remaining structures. The ultraviolet (UV) excimer laser is capable of such precise tissue removal due to the penetration depth of 193 nm and 248 nm irradiation of 1 micron per pulse. This type of ablative tissue removal requires a high repetition rate for efficient lesional destruction. Excimer laser radiation at 193 nm is capable of high repetition rates, which are necessary while 248 nm radiation causes increasing nonspecific thermal injury as the laser repetition rate is increased.

  20. Very high repetition-rate electro-optical cavity-dumped Nd: YVO4 laser with optics and dynamics stabilities

    Science.gov (United States)

    Liu, Xuesong; Shi, Zhaohui; Huang, Yutao; Fan, Zhongwei; Yu, Jin; Zhang, Jing; Hou, Liqun

    2015-02-01

    In this paper, a very high repetition-rate, short-pulse, electro-optical cavity-dumped Nd: YVO4 laser is experimentally and theoretically investigated. The laser performance is optimized from two aspects. Firstly, the laser resonator is designed for a good thermal stability under large pump power fluctuation through optics methods. Secondly, dynamics simulation as well as experiments verifies that cavity dumping at very high repetition rate has better stability than medium/high repetition rate. At 30 W, 880 nm pump power, up to 500 kHz, constant 5 ns, stable 1064 nm fundamental-mode laser pulses can be obtained with 10 W average output power.

  1. Vibrational sum-frequency generation spectroscopy of lipid bilayers at repetition rates up to 100 kHz

    Science.gov (United States)

    Yesudas, Freeda; Mero, Mark; Kneipp, Janina; Heiner, Zsuzsanna

    2018-03-01

    Broadband vibrational sum-frequency generation (BB-VSFG) spectroscopy has become a well-established surface analytical tool capable of identifying the orientation and structure of molecular layers. A straightforward way to boost the sensitivity of the technique could be to increase the laser repetition rate beyond that of standard BB-VSFG spectrometers, which rely on Ti:sapphire lasers operating at repetition rates of 1-5 kHz. Nevertheless, possible thermally induced artifacts in the vibrational spectra due to higher laser average powers are unexplored. Here, we discuss laser power induced temperature accumulation effects that distort the BB-VSFG spectra of 1,2-diacyl-sn-glycero-3-phosphocholine at an interface between two transparent phases at repetition rates of 5, 10, 50, and 100 kHz at constant pulse energy. No heat-induced distortions were found in the spectra, suggesting that the increase in the laser repetition rate provides a feasible route to an improved signal-to-noise ratio or shorter data acquisition times in BB-VSFG spectroscopy for thin films on transparent substrates. The results have implications for future BB-VSFG spectrometers pushing the detection limit for molecular layers with low surface coverage.

  2. Effect of Bench Press Load Knowledge on Repetitions, Rating of Perceived Exertion, and Attentional Focus.

    Science.gov (United States)

    Beaudoin, Christina M; Cox, Zachary; Dundore, Tyler; Thomas, Tayler; Kim, Johnathon; Pillivant, Daniel

    2018-02-01

    Beaudoin, CM, Cox, Z, Dundore, T, Thomas, T, Kim, J, and Pillivant, D. Effect of bench press load knowledge on repetitions, rating of perceived exertion, and attentional focus. J Strength Cond Res 32(2): 514-519, 2018-Few studies have examined the role of the teleoanticipation during resistance training. The purpose of this study was to examine the effect of bench press (BP) load knowledge on repetitions completed, ratings of perceived exertion (RPEs), and attentional focus (% associative). Thirty-six recreationally active resistance-trained men (n = 25) and women (n = 11) participated in this study (age = 20.97 ± 1.87 years; ht = 174.12 ± 9.41 cm; and mass = 80.14 ± 14.03 kg). All subjects completed 3 testing sessions: (a) 1 repetition maximum (1RM) BP determination; (b) submaximal BP repetitions to fatigue known load (KL); and (c) submaximal BP repetitions to fatigue unknown load (UL). Known load and UL sessions were randomized and counterbalanced and both completed at 70% 1RM. An estimated weight ratio was computed using the subject's estimate of the UL weight relative to the KL weight. An independent samples t-test revealed no significant testing order difference for the estimated weight ratio. Two-way repeated-measures analysis of variances revealed no significant differences in the number of repetitions (p = 0.63), RPE (p = 0.18), or attentional focus (% associative) (p = 0.93) between the KL and UL conditions. Pearson correlations found a moderate positive association between KL repetitions completed and % associative focus when the UL was completed before the KL. Load knowledge did not influence the number of repetitions, RPE, or attentional focus while completing the BP. Further research examining the use of pacing strategies, RPE, and attentional focus during KL and UL conditions are warranted.

  3. Advances in high repetition rate, ultra-short, gigawatt laser systems for time-resolved spectroscopy

    International Nuclear Information System (INIS)

    DiMauro, L.F.

    1991-01-01

    The objective of this article is to emphasize the current advances in the development of high-repetition rate amplifier pumps. Although this review highlights amplifier pump development, any recent data from achieved outputs via the tunable amplifier section is also discussed. The first section describes desirable parameters attributable to the pump amplifier while the rest of the article deals with specific examples for various options. The pump amplifiers can be characterized into two distinct classes; those achieving operation in the hundred hertz regime and those performing at repetition rates ≥1kHz. 23 refs., 4 figs

  4. Ultrafast, high repetition rate, ultraviolet, fiber-laser-based source: application towards Yb+ fast quantum-logic.

    Science.gov (United States)

    Hussain, Mahmood Irtiza; Petrasiunas, Matthew Joseph; Bentley, Christopher D B; Taylor, Richard L; Carvalho, André R R; Hope, Joseph J; Streed, Erik W; Lobino, Mirko; Kielpinski, David

    2016-07-25

    Trapped ions are one of the most promising approaches for the realization of a universal quantum computer. Faster quantum logic gates could dramatically improve the performance of trapped-ion quantum computers, and require the development of suitable high repetition rate pulsed lasers. Here we report on a robust frequency upconverted fiber laser based source, able to deliver 2.5 ps ultraviolet (UV) pulses at a stabilized repetition rate of 300.00000 MHz with an average power of 190 mW. The laser wavelength is resonant with the strong transition in Ytterbium (Yb+) at 369.53 nm and its repetition rate can be scaled up using high harmonic mode locking. We show that our source can produce arbitrary pulse patterns using a programmable pulse pattern generator and fast modulating components. Finally, simulations demonstrate that our laser is capable of performing resonant, temperature-insensitive, two-qubit quantum logic gates on trapped Yb+ ions faster than the trap period and with fidelity above 99%.

  5. Development of a high repetition rate laser-plasma accelerator for ultra-fast electron diffraction experiments

    International Nuclear Information System (INIS)

    Beaurepaire, B.

    2009-01-01

    Electronic microscopy and electron diffraction allowed the understanding of the organization of atoms in matter. Using a temporally short source, one can measure atomic displacements or modifications of the electronic distribution in matter. To date, the best temporal resolution for time resolved diffraction experiments is of the order of a hundred femto-seconds (fs). Laser accelerators are good candidates to reach the femtosecond temporal resolution in electron diffraction experiments. Such accelerators used to work at a low repetition rate, so that it was necessary to develop a new one operating at a high repetition rate in order to accumulate a large amount of data. In this thesis, a laser-plasma accelerator operating at the kHz repetition rate was developed and built. This source generates electron bunches at 100 keV from 3 mJ and 25 fs laser pulses. The physics of the acceleration has been studied, and the effect of the laser wavefront on the electron transverse distribution has been demonstrated. (author)

  6. Repetitive exposure: Brain and reflex measures of emotion and attention

    Science.gov (United States)

    Ferrari, Vera; Bradley, Margaret M.; Codispoti, Maurizio; Lang, Peter J.

    2010-01-01

    Effects of massed repetition on the modulation of the late positive potential elicited during affective picture viewing were investigated in two experiments. Despite a difference in the number of repetitions across studies (from 5 to 30), results were quite similar: the late positive potential continued to be enhanced when viewing emotional, compared to neutral, pictures. On the other hand, massed repetition did prompt a reduction in the late positive potential that was most pronounced for emotional pictures. Startle probe P3 amplitude generally increased with repetition, suggesting diminished attention allocation to repeated pictures. The blink reflex, however, continued to be modulated by hedonic valence, despite massive massed repetition. Taken together, the data suggest that the amplitude of the late positive potential during picture viewing reflects both motivational significance and attention allocation. PMID:20701711

  7. High-energy, high-repetition-rate picosecond pulses from a quasi-CW diode-pumped Nd:YAG system.

    Science.gov (United States)

    Noom, Daniel W E; Witte, Stefan; Morgenweg, Jonas; Altmann, Robert K; Eikema, Kjeld S E

    2013-08-15

    We report on a high-power quasi-CW pumped Nd:YAG laser system, producing 130 mJ, 64 ps pulses at 1064 nm wavelength with a repetition rate of 300 Hz. Pulses from a Nd:YVO(4) oscillator are first amplified by a regenerative amplifier to the millijoule level and then further amplified in quasi-CW diode-pumped Nd:YAG modules. Pulsed diode pumping enables a high gain at repetition rates of several hundred hertz, while keeping thermal effects manageable. Birefringence compensation and multiple thermal-lensing-compensated relay-imaging stages are used to maintain a top-hat beam profile. After frequency doubling, 75 mJ pulses are obtained at 532 nm. The intensity stability is better than 1.1%, which makes this laser an attractive pump source for a high-repetition-rate optical parametric amplification system.

  8. Effects of high repetition rate and beam size on hard tissue damage due to subpicosecond laser pulses

    International Nuclear Information System (INIS)

    Kim, Beop-Min; Feit, Michael D.; Rubenchik, Alexander M.; Joslin, Elizabeth J.; Eichler, Juergen; Stoller, Patrick C.; Da Silva, Luiz B.

    2000-01-01

    We report the effects of the repetition rate and the beam size on the threshold for ultrashort laser pulse induced damage in dentin. The observed results are explained as cumulative thermal effects. Our model is consistent with the experimental results and explains the dependence of the threshold on repetition rate, beam size, and exposure time. (c) 2000 American Institute of Physics

  9. A high repetition rate XUV seeding source for FLASH2

    International Nuclear Information System (INIS)

    Willner, Arik

    2012-05-01

    Improved performance of free-electron laser (FEL) light sources in terms of timing stability, pulse shape and spectral properties of the amplified FEL pulses is of interest in material science, the fields of ultrafast dynamics, biology, chemistry and even special branches in industry. A promising scheme for such an improvement is direct seeding with high harmonic generation (HHG) in a noble gas target. A free-electron laser seeded by an external extreme ultraviolet (XUV) source is planned for FLASH2 at DESY in Hamburg. The requirements for the XUV/soft X-ray source can be summarized as follows: A repetition rate of at least 100 kHz in a 10 Hz burst is needed at variable wavelengths from 10 to 40 nm and pulse energies of several nJ within a single laser harmonic. This application requires a laser amplifier system with exceptional parameters, mJ-level pulse energy, 10-15 fs pulse duration at 100 kHz (1 MHz) burst repetition rate. A new optical parametric chirped-pulse amplification (OPCPA) system is under development in order to meet these requirements, and very promising results have been achieved in the last three years. In parallel to this development, a new HHG concept is necessary to sustain high average power of the driving laser system and to generate harmonics with high conversion efficiencies. Currently, the highest conversion efficiency with HHG has been demonstrated using gas-filled capillary targets. For our application, only a free-jet target can be used for HHG, in order to overcome damage threshold limitations of HHG target optics at a high repetition rate. A novel dual-gas multijet gas target has been developed and first experiments show remarkable control of the degree of phase matching forming the basis for improved control of the harmonic photon flux and the XUV pulse characteristics. The basic idea behind the dual-gas concept is the insertion of matching zones in between multiple HHG sources. These matching sections are filled with hydrogen which

  10. A high repetition rate XUV seeding source for FLASH2

    Energy Technology Data Exchange (ETDEWEB)

    Willner, Arik

    2012-05-15

    Improved performance of free-electron laser (FEL) light sources in terms of timing stability, pulse shape and spectral properties of the amplified FEL pulses is of interest in material science, the fields of ultrafast dynamics, biology, chemistry and even special branches in industry. A promising scheme for such an improvement is direct seeding with high harmonic generation (HHG) in a noble gas target. A free-electron laser seeded by an external extreme ultraviolet (XUV) source is planned for FLASH2 at DESY in Hamburg. The requirements for the XUV/soft X-ray source can be summarized as follows: A repetition rate of at least 100 kHz in a 10 Hz burst is needed at variable wavelengths from 10 to 40 nm and pulse energies of several nJ within a single laser harmonic. This application requires a laser amplifier system with exceptional parameters, mJ-level pulse energy, 10-15 fs pulse duration at 100 kHz (1 MHz) burst repetition rate. A new optical parametric chirped-pulse amplification (OPCPA) system is under development in order to meet these requirements, and very promising results have been achieved in the last three years. In parallel to this development, a new HHG concept is necessary to sustain high average power of the driving laser system and to generate harmonics with high conversion efficiencies. Currently, the highest conversion efficiency with HHG has been demonstrated using gas-filled capillary targets. For our application, only a free-jet target can be used for HHG, in order to overcome damage threshold limitations of HHG target optics at a high repetition rate. A novel dual-gas multijet gas target has been developed and first experiments show remarkable control of the degree of phase matching forming the basis for improved control of the harmonic photon flux and the XUV pulse characteristics. The basic idea behind the dual-gas concept is the insertion of matching zones in between multiple HHG sources. These matching sections are filled with hydrogen which

  11. Characterization of a high repetition-rate laser-driven short-pulsed neutron source

    Science.gov (United States)

    Hah, J.; Nees, J. A.; Hammig, M. D.; Krushelnick, K.; Thomas, A. G. R.

    2018-05-01

    We demonstrate a repetitive, high flux, short-pulsed laser-driven neutron source using a heavy-water jet target. We measure neutron generation at 1/2 kHz repetition rate using several-mJ pulse energies, yielding a time-averaged neutron flux of 2 × 105 neutrons s‑1 (into 4π steradians). Deuteron spectra are also measured in order to understand source characteristics. Analyses of time-of-flight neutron spectra indicate that two separate populations of neutrons, ‘prompt’ and ‘delayed’, are generated at different locations. Gamma-ray emission from neutron capture 1H(n,γ) is also measured to confirm the neutron flux.

  12. Repetition rate multiplication of frequency comb using all-pass fiber resonator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lijun; Yang, Honglei; Zhang, Hongyuan; Wei, Haoyun; Li, Yan, E-mail: liyan@mail.tsinghua.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing 100084 (China)

    2016-09-15

    We propose a stable method for repetition rate multiplication of a 250-MHz Er-fiber frequency comb by a phase-locked all-pass fiber ring resonator, whose phase-locking configuration is simple. The optical path length of the fiber ring resonator is automatically controlled to be accurately an odd multiple of half of the original cavity length using an electronical phase-locking unit with an optical delay line. As for shorter cavity length of the comb, high-order odd multiple is preferable. Because the power loss depends only on the net-attenuation of the fiber ring resonator, the energetic efficiency of the proposed method is high. The input and output optical spectrums show that the spectral width of the frequency comb is clearly preserved. Besides, experimental results show less pulse intensity fluctuation and 35 dB suppression ratio of side-modes while providing a good long-term and short-term frequency stability. Higher-order repetition rate multiplication to several GHz can be obtained by using several fiber ring resonators in cascade configuration.

  13. Repetition rate multiplication of frequency comb using all-pass fiber resonator

    International Nuclear Information System (INIS)

    Yang, Lijun; Yang, Honglei; Zhang, Hongyuan; Wei, Haoyun; Li, Yan

    2016-01-01

    We propose a stable method for repetition rate multiplication of a 250-MHz Er-fiber frequency comb by a phase-locked all-pass fiber ring resonator, whose phase-locking configuration is simple. The optical path length of the fiber ring resonator is automatically controlled to be accurately an odd multiple of half of the original cavity length using an electronical phase-locking unit with an optical delay line. As for shorter cavity length of the comb, high-order odd multiple is preferable. Because the power loss depends only on the net-attenuation of the fiber ring resonator, the energetic efficiency of the proposed method is high. The input and output optical spectrums show that the spectral width of the frequency comb is clearly preserved. Besides, experimental results show less pulse intensity fluctuation and 35 dB suppression ratio of side-modes while providing a good long-term and short-term frequency stability. Higher-order repetition rate multiplication to several GHz can be obtained by using several fiber ring resonators in cascade configuration.

  14. Diffusively cooled thin-sheath high-repetition-rate TEA and TEMA lasers

    Science.gov (United States)

    Yatsiv, Shaul; Gabay, Amnon; Sintov, Yoav

    1993-05-01

    Transverse electric atmospheric (TEA), or multi atmospheric (TEMA) lasers deliver intense short laser pulses of considerable energies. Recurrent high repetition rate pulse trains afford substantial average power levels. In a high rep-rate operation the gas flows across the cavity and is externally cooled to maintain a reasonably low temperature. The gas flow gear and heat exchanger are bulky and costly. In this work we present a repetitively pulsed TEA or TEMA laser that combines energy and peak power features in an individual pulse with the substantial average power levels of a pulse train in a thin layer of gas. Excess heat is disposed of, by conduction through the gas, to cooled enclosing walls. The gas does not flow. The method applies to vibrational transition molecular lasers in the infrared, where elevated temperatures are deleterious to the laser operation. The gist of the method draws on the law that heat conductivity in gases does not depend on their pressure. The fact lends unique operational flexibility and compactness, desirable for industrial and research purposes.

  15. High repetition rate laser-driven MeV ion acceleration at variable background pressures

    Science.gov (United States)

    Snyder, Joseph; Ngirmang, Gregory; Orban, Chris; Feister, Scott; Morrison, John; Frische, Kyle; Chowdhury, Enam; Roquemore, W. M.

    2017-10-01

    Ultra-intense laser-plasma interactions (LPI) can produce highly energetic photons, electrons, and ions with numerous potential real-world applications. Many of these applications will require repeatable, high repetition targets that are suitable for LPI experiments. Liquid targets can meet many of these needs, but they typically require higher chamber pressure than is used for many low repetition rate experiments. The effect of background pressure on the LPI has not been thoroughly studied. With this in mind, the Extreme Light group at the Air Force Research Lab has carried out MeV ion and electron acceleration experiments at kHz repetition rate with background pressures ranging from 30 mTorr to >1 Torr using a submicron ethylene glycol liquid sheet target. We present these results and provide two-dimensional particle-in-cell simulation results that offer insight on the thresholds for the efficient acceleration of electrons and ions. This research is supported by the Air Force Office of Scientific Research under LRIR Project 17RQCOR504 under the management of Dr. Riq Parra and Dr. Jean-Luc Cambier. Support was also provided by the DOD HPCMP Internship Program.

  16. Compact and high repetition rate Kerr-lens mode-locked 532 nm Nd:YVO4 laser

    International Nuclear Information System (INIS)

    Li, Zuohan; Peng, Jiying; Yuan, Ruixia; Yao, Jianquan; Zheng, Yi; Wang, Tongtong

    2015-01-01

    A compact and feasible CW Kerr-lens-induced mode-locked 532 nm Nd:YVO 4 laser system was experimentally demonstrated for the first time with theoretical analysis. Kerr-lens mode locking with intracavity second harmonic generation provides a promising method to generate a high-repetition-rate picosecond green laser. With an incident pump power of 6 W, the average output power of mode locking was 258 mW at a high repetition rate of 1.1 GHz. (paper)

  17. Optimization and phase matching of fiber-laser-driven high-order harmonic generation at high repetition rate.

    Science.gov (United States)

    Cabasse, Amélie; Machinet, Guillaume; Dubrouil, Antoine; Cormier, Eric; Constant, Eric

    2012-11-15

    High-repetition-rate sources are very attractive for high-order harmonic generation (HHG). However, due to their pulse characteristics (low energy, long duration), those systems require a tight focusing geometry to achieve the necessary intensity to generate harmonics. In this Letter, we investigate theoretically and experimentally the optimization of HHG in this geometry, to maximize the extreme UV (XUV) photon flux and improve the conversion efficiency. We analyze the influence of atomic gas media (Ar, Kr, or Xe), gas pressure, and interaction geometries (a gas jet and a finite and a semi-infinite gas cell). Numerical simulations allow us to define optimal conditions for HHG in this tight focusing regime and to observe the signature of on-axis phase matching. These conditions are implemented experimentally using a high-repetition-rate Yb-doped fiber laser system. We achieve optimization of emission with a recorded XUV photon flux of 4.5×10(12) photons/s generated in Xe at 100 kHz repetition rate.

  18. Laser-diode pumped self-mode-locked praseodymium visible lasers with multi-gigahertz repetition rate.

    Science.gov (United States)

    Zhang, Yuxia; Yu, Haohai; Zhang, Huaijin; Di Lieto, Alberto; Tonelli, Mauro; Wang, Jiyang

    2016-06-15

    We demonstrate efficient laser-diode pumped multi-gigahertz (GHz) self-mode-locked praseodymium (Pr3+) visible lasers with broadband spectra from green to deep red for the first time to our knowledge. With a Pr3+-doped GdLiF4 crystal, stable self-mode-locked visible pulsed lasers at the wavelengths of 522 nm, 607 nm, 639 nm, and 720 nm have been obtained with the repetition rates of 2.8 GHz, 3.1 GHz, 3.1 GHz, and 3.0 GHz, respectively. The maximum output power was 612 mW with the slope efficiency of 46.9% at 639 nm. The mode-locking mechanism was theoretically analyzed. The stable second-harmonic mode-locking with doubled repetition frequency was also realized based on the Fabry-Perot effect formed in the laser cavity. In addition, we find that the polarization directions were turned with lasing wavelengths. This work may provide a new way for generating efficient ultrafast pulses with high- and changeable-repetition rates in the visible range.

  19. Oral-diadochokinetic rates for Hebrew-speaking school-age children: real words vs. non-words repetition.

    Science.gov (United States)

    Icht, Michal; Ben-David, Boaz M

    2015-02-01

    Oral-diadochokinesis (DDK) tasks are a common tool for evaluating speech disorders. Usually, these tasks involve repetitions of non-words. It has been suggested that repeating real words can be more suitable for preschool children. But, the impact of using real words with elementary school children has not been studied yet. This study evaluated oral-DDK rates for Hebrew-speaking elementary school children using non-words and real words. The participants were 60 children, 9-11 years old, with normal speech and language development, who were asked to repeat "pataka" (non-word) and "bodeket" (Hebrew real word). Data replicate the advantage generally found for real word repetition with preschoolers. Children produced real words faster than non-words for all age groups, and repetition rates were higher for the older children. The findings suggest that adding real words to the standard oral-DDK task with elementary school children may provide a more comprehensive picture of oro-motor function.

  20. A Simulation of the Effects of Varying Repetition Rate and Pulse Width of Nanosecond Discharges on Premixed Lean Methane-Air Combustion

    Directory of Open Access Journals (Sweden)

    Moon Soo Bak

    2012-01-01

    Full Text Available Two-dimensional kinetic simulation has been carried out to investigate the effects of repetition rate and pulse width of nanosecond repetitively pulsed discharges on stabilizing premixed lean methane-air combustion. The repetition rate and pulse width are varied from 10 kHz to 50 kHz and from 9 ns to 2 ns while the total power is kept constant. The lower repetition rates provide larger amounts of radicals such as O, H, and OH. However, the effect on stabilization is found to be the same for all of the tested repetition rates. The shorter pulse width is found to favor the production of species in higher electronic states, but the varying effects on stabilization are also found to be small. Our results indicate that the total deposited power is the critical element that determines the extent of stabilization over this range of discharge properties studied.

  1. Low-timing-jitter, stretched-pulse passively mode-locked fiber laser with tunable repetition rate and high operation stability

    International Nuclear Information System (INIS)

    Liu, Yuanshan; Zhang, Jian-Guo; Chen, Guofu; Zhao, Wei; Bai, Jing

    2010-01-01

    We design a low-timing-jitter, repetition-rate-tunable, stretched-pulse passively mode-locked fiber laser by using a nonlinear amplifying loop mirror (NALM), a semiconductor saturable absorber mirror (SESAM), and a tunable optical delay line in the laser configuration. Low-timing-jitter optical pulses are stably produced when a SESAM and a 0.16 m dispersion compensation fiber are employed in the laser cavity. By inserting a tunable optical delay line between NALM and SESAM, the variable repetition-rate operation of a self-starting, passively mode-locked fiber laser is successfully demonstrated over a range from 49.65 to 50.47 MHz. The experimental results show that the newly designed fiber laser can maintain the mode locking at the pumping power of 160 mW to stably generate periodic optical pulses with width less than 170 fs and timing jitter lower than 75 fs in the 1.55 µm wavelength region, when the fundamental repetition rate of the laser is continuously tuned between 49.65 and 50.47 MHz. Moreover, this fiber laser has a feature of turn-key operation with high repeatability of its fundamental repetition rate in practice

  2. MHz repetition rate solid-state driver for high current induction accelerators

    International Nuclear Information System (INIS)

    Brooksby, C; Caporaso, G; Goerz, D; Hanks, R; Hickman, B; Kirbie, H; Lee, B; Saethre, R.

    1999-01-01

    A research team from the Lawrence Livermore National Laboratory and Bechtel Nevada Corporation is developing an all solid-state power source for high current induction accelerators. The original power system design, developed for heavy-ion fusion accelerators, is based on the simple idea of using an array of field effect transistors to switch energy from a pre-charged capacitor bank to an induction accelerator cell. Recently, that idea has been expanded to accommodate the greater power needs of a new class of high-current electron accelerators for advanced radiography. For this purpose, we developed a 3-stage induction adder that uses over 4,000 field effect transistors to switch peak voltages of 45 kV at currents up to 4.8 kA with pulse repetition rates of up to 2 MHz. This radically advanced power system can generate a burst of five or more pulses that vary from 200 ns to 2 ampersand micro;s at a duty cycle of up to 25%. Our new source is precise, robust, flexible, and exceeds all previous drivers for induction machines by a factor of 400 in repetition rate and a factor of 1000 in duty cycle

  3. Pulsed laser deposition of SrRuO3 thin-films: The role of the pulse repetition rate

    Directory of Open Access Journals (Sweden)

    H. Schraknepper

    2016-12-01

    Full Text Available SrRuO3 thin-films were deposited with different pulse repetition rates, fdep, epitaxially on vicinal SrTiO3 substrates by means of pulsed laser deposition. The measurement of several physical properties (e.g., composition by means of X-ray photoelectron spectroscopy, the out-of-plane lattice parameter, the electric conductivity, and the Curie temperature consistently reveals that an increase in laser repetition rate results in an increase in ruthenium deficiency in the films. By the same token, it is shown that when using low repetition rates, approaching a nearly stoichiometric cation ratio in SrRuO3 becomes feasible. Based on these results, we propose a mechanism to explain the widely observed Ru deficiency of SrRuO3 thin-films. Our findings demand these theoretical considerations to be based on kinetic rather than widely employed thermodynamic arguments.

  4. High repetition rate ultrashort laser cuts a path through fog

    Science.gov (United States)

    de la Cruz, Lorena; Schubert, Elise; Mongin, Denis; Klingebiel, Sandro; Schultze, Marcel; Metzger, Thomas; Michel, Knut; Kasparian, Jérôme; Wolf, Jean-Pierre

    2016-12-01

    We experimentally demonstrate that the transmission of a 1030 nm, 1.3 ps laser beam of 100 mJ energy through fog increases when its repetition rate increases to the kHz range. Due to the efficient energy deposition by the laser filaments in the air, a shockwave ejects the fog droplets from a substantial volume of the beam, at a moderate energy cost. This process opens prospects for applications requiring the transmission of laser beams through fogs and clouds.

  5. Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook Univ., NY (United States). Dept. of Physics and Astronomy. Center for Accelerator Science and Education

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). Below details the Principal Investigators and contact information. Each PI submits separately for a budget through his corresponding institute. The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-­conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-­antimonide cathodes (BNL – LBNL) b) Development and testing of a diamond amplifier for photocathodes (SBU -­ BNL) c) Tests of both cathodes in superconducting RF photoguns (SBU) and copper RF photoguns (LBNL) Our work made extensive use of synchrotron radiation materials science techniques, such as powder-­ and single-­crystal diffraction, x-­ray fluorescence, EXAFS and variable energy XPS. BNL and LBNL have many complementary facilities at the two light sources associated with these laboratories (NSLS and ALS, respectively); use of these will be a major thrust of our program and bring our understanding of these complex materials to a new level. In addition, CHESS at Cornell will be used to continue seamlessly throughout the NSLS dark period and

  6. Diagnostic for a high-repetition rate electron photo-gun and first measurements

    Science.gov (United States)

    Filippetto, D.; Doolittle, L.; Huang, G.; Norum, E.; Portmann, G.; Qian, H.; Sannibale, F.

    2015-05-01

    The APEX electron source at LBNL combines the high-repetition-rate with the high beam brightness typical of photoguns, delivering low emittance electron pulses at MHz frequency. Proving the high beam quality of the beam is an essential step for the success of the experiment, opening the doors of the high average power to brightness-hungry applications as X-Ray FELs, MHz ultrafast electron diffraction etc.. As first step, a complete characterization of the beam parameters is foreseen at the Gun beam energy of 750 keV. Diagnostics for low and high current measurements have been installed and tested, and measurements of cathode lifetime and thermal emittance in a RF environment with mA current performed. The recent installation of a double slit system, a deflecting cavity and a high precision spectrometer, allow the exploration of the full 6D phase space. Here we discuss the present layout of the machine and future upgrades, showing the latest results at low and high repetition rate, together with the tools and techniques used.

  7. Influence of Music Style and Rate on Repetitive Finger Tapping.

    Science.gov (United States)

    Stegemöller, Elizabeth L; Tatz, Joshua R; Warnecke, Alison; Hibbing, Paul; Bates, Brandon; Zaman, Andrew

    2018-03-09

    Auditory cues, including music, are commonly used in the treatment of persons with Parkinson's disease. Yet, how music style and movement rate modulate movement performance in persons with Parkinson's disease have been neglected and remain limited in healthy young populations. The purpose of this study was to determine how music style and movement rate influence movement performance in healthy young adults. Healthy participants were asked to perform repetitive finger movements at two pacing rates (70 and 140 beats per minute) for the following conditions: (a) a tone only, (b) activating music, and (c) relaxing music. Electromyography, movement kinematics, and variability were collected. Results revealed that the provision of music, regardless of style, reduced amplitude variability at both pacing rates. Intermovement interval was longer, and acceleration variability was reduced during both music conditions at the lower pacing rate only. These results may prove beneficial for designing therapeutic interventions for persons with Parkinson's disease.

  8. 300-MHz-repetition-rate, all-fiber, femtosecond laser mode-locked by planar lightwave circuit-based saturable absorber.

    Science.gov (United States)

    Kim, Chur; Kim, Dohyun; Cheong, YeonJoon; Kwon, Dohyeon; Choi, Sun Young; Jeong, Hwanseong; Cha, Sang Jun; Lee, Jeong-Woo; Yeom, Dong-Il; Rotermund, Fabian; Kim, Jungwon

    2015-10-05

    We show the implementation of fiber-pigtailed, evanescent-field-interacting, single-walled carbon nanotube (CNT)-based saturable absorbers (SAs) using standard planar lightwave circuit (PLC) fabrication processes. The implemented PLC-CNT-SA device is employed to realize self-starting, high-repetition-rate, all-fiber ring oscillators at telecommunication wavelength. We demonstrate all-fiber Er ring lasers operating at 303-MHz (soliton regime) and 274-MHz (stretched-pulse regime) repetition-rates. The 303-MHz (274-MHz) laser centered at 1555 nm (1550 nm) provides 7.5 nm (19 nm) spectral bandwidth. After extra-cavity amplilfication, the amplified pulse train of the 303-MHz (274-MHz) laser delivers 209 fs (178 fs) pulses. To our knowledge, this corresponds to the highest repetition-rates achieved for femtosecond lasers employing evanescent-field-interacting SAs. The demonstrated SA fabrication method, which is based on well-established PLC processes, also shows a potential way for mass-producible and lower-cost waveguide-type SA devices suitable for all-fiber and waveguide lasers.

  9. Efficient high-peak-power and high-repetition-rate eye-safe laser using an intracavity KTP OPO

    International Nuclear Information System (INIS)

    Guo, J; Jiao, Z X; Wang, B; He, G Y

    2015-01-01

    An efficient high-peak-power and high-repetition-rate intracavity KTP optical parametric oscillator pumped by a Q-switched Nd:YVO 4 laser is demonstrated. We achieved 1.5 W output power of 1.5 μm at 10 kHz repetition rate with the pulse duration of 6 ns. The maximum peak power of 25 kW and the maximum pulse energy of 150 μJ have been obtained. The maximum conversion efficiency of 9.5% is achieved with respect to a laser diode power of 10.5 W. (paper)

  10. Development of a Watt-level gamma-ray source based on high-repetition-rate inverse Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Mihalcea, D.; Murokh, A.; Piot, P.; Ruan, J.

    2017-07-01

    A high-brilliance (~1022 photon s-1 mm-2 mrad-2 /0.1%) gamma-ray source experiment is currently being planned at Fermilab (Eγ≃1.1 MeV). The source implements a high-repetition-rate inverse Compton scattering by colliding electron bunches formed in a ~300-MeV superconducting linac with a high-intensity laser pulse. This paper describes the design rationale along with some of technical challenges associated to producing high-repetition-rate collision. The expected performances of the gamma-ray source are also presented.

  11. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    Science.gov (United States)

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  12. Research on the optoacoustic communication system for speech transmission by variable laser-pulse repetition rates

    Science.gov (United States)

    Jiang, Hongyan; Qiu, Hongbing; He, Ning; Liao, Xin

    2018-06-01

    For the optoacoustic communication from in-air platforms to submerged apparatus, a method based on speech recognition and variable laser-pulse repetition rates is proposed, which realizes character encoding and transmission for speech. Firstly, the theories and spectrum characteristics of the laser-generated underwater sound are analyzed; and moreover character conversion and encoding for speech as well as the pattern of codes for laser modulation is studied; lastly experiments to verify the system design are carried out. Results show that the optoacoustic system, where laser modulation is controlled by speech-to-character baseband codes, is beneficial to improve flexibility in receiving location for underwater targets as well as real-time performance in information transmission. In the overwater transmitter, a pulse laser is controlled to radiate by speech signals with several repetition rates randomly selected in the range of one to fifty Hz, and then in the underwater receiver laser pulse repetition rate and data can be acquired by the preamble and information codes of the corresponding laser-generated sound. When the energy of the laser pulse is appropriate, real-time transmission for speaker-independent speech can be realized in that way, which solves the problem of underwater bandwidth resource and provides a technical approach for the air-sea communication.

  13. Heavy-duty high-repetition-rate generators

    NARCIS (Netherlands)

    Heesch, van E.J.M.; Yan, K.; Pemen, A.J.M.

    2002-01-01

    We present our results on high-power repetitive pulse sources for continuous operation. Two 1-10-kW systems using advanced spark gap technology and a transmission line transformer have been tested for several hundred hours at a 60-MW pulse level. High reliability and above 90% overall efficiency are

  14. High repetition rate, high energy, actively Q-switched all-in-fiber laser

    Science.gov (United States)

    Lecourt, J. B.; Bertrand, A.; Guillemet, S.; Hernandez, Y.; Giannone, D.

    2010-05-01

    We report an actively Q-switched Ytterbium-doped all-in-fibre laser delivering 10ns pulses with high repetition rate (from 100kHz to 1MHz). The laser operation has been validated at three different wavelengths (1040, 1050 and 1064nm). The laser can deliver up to 20Watts average power with an high beam quality (M2 = 1).

  15. A fast 30 kV 5 kHz repetition rate resonant capacitor charger

    NARCIS (Netherlands)

    Beckers, F.J.C.M.; Huiskamp, T.; van Heesch, E.J.M.; Pemen, A.J.M.

    2016-01-01

    A novel circuit topology of a fast 30 kV resonant capacitor charger is presented in this paper. The charger is designed for high repetition rate spark gap based pulsed power modulators. A spark gap can fire spontaneously (pre-firing) during charging of a capacitor bank due to poor dielectric

  16. An optical parametric chirped-pulse amplifier for seeding high repetition rate free-electron lasers

    International Nuclear Information System (INIS)

    Höppner, H; Hage, A; Tanikawa, T; Schulz, M; Faatz, B; Riedel, R; Prandolini, M J; Teubner, U; Tavella, F

    2015-01-01

    High repetition rate free-electron lasers (FEL), producing highly intense extreme ultraviolet and x-ray pulses, require new high power tunable femtosecond lasers for FEL seeding and FEL pump-probe experiments. A tunable, 112 W (burst mode) optical parametric chirped-pulse amplifier (OPCPA) is demonstrated with center frequencies ranging from 720–900 nm, pulse energies up to 1.12 mJ and a pulse duration of 30 fs at a repetition rate of 100 kHz. Since the power scalability of this OPCPA is limited by the OPCPA-pump amplifier, we also demonstrate a 6.7–13.7 kW (burst mode) thin-disk OPCPA-pump amplifier, increasing the possible OPCPA output power to many hundreds of watts. Furthermore, third and fourth harmonic generation experiments are performed and the results are used to simulate a seeded FEL with high-gain harmonic generation. (paper)

  17. Impact of visual repetition rate on intrinsic properties of low frequency fluctuations in the visual network.

    Directory of Open Access Journals (Sweden)

    Yi-Chia Li

    Full Text Available BACKGROUND: Visual processing network is one of the functional networks which have been reliably identified to consistently exist in human resting brains. In our work, we focused on this network and investigated the intrinsic properties of low frequency (0.01-0.08 Hz fluctuations (LFFs during changes of visual stimuli. There were two main questions to be discussed in this study: intrinsic properties of LFFs regarding (1 interactions between visual stimuli and resting-state; (2 impact of repetition rate of visual stimuli. METHODOLOGY/PRINCIPAL FINDINGS: We analyzed scanning sessions that contained rest and visual stimuli in various repetition rates with a novel method. The method included three numerical approaches involving ICA (Independent Component Analyses, fALFF (fractional Amplitude of Low Frequency Fluctuation, and Coherence, to respectively investigate the modulations of visual network pattern, low frequency fluctuation power, and interregional functional connectivity during changes of visual stimuli. We discovered when resting-state was replaced by visual stimuli, more areas were involved in visual processing, and both stronger low frequency fluctuations and higher interregional functional connectivity occurred in visual network. With changes of visual repetition rate, the number of areas which were involved in visual processing, low frequency fluctuation power, and interregional functional connectivity in this network were also modulated. CONCLUSIONS/SIGNIFICANCE: To combine the results of prior literatures and our discoveries, intrinsic properties of LFFs in visual network are altered not only by modulations of endogenous factors (eye-open or eye-closed condition; alcohol administration and disordered behaviors (early blind, but also exogenous sensory stimuli (visual stimuli with various repetition rates. It demonstrates that the intrinsic properties of LFFs are valuable to represent physiological states of human brains.

  18. Experimental investigation of different regimes of mode-locking in a high repetition rate passively mode-locked semiconductor quantum-dot laser.

    Science.gov (United States)

    Kéfélian, Fabien; O'Donoghue, Shane; Todaro, Maria Teresa; McInerney, John; Huyet, Guillaume

    2009-04-13

    We report experimental investigations on a two-section 16-GHz repetition rate InAs/GaAs quantum dot passively mode-locked laser. Near the threshold current, pseudo-periodic Q-switching with complex dynamics is exhibited. Mode-locking operation regimes characterized by different repetition rates and timing jitter levels are encountered up to twice the threshold current. Evolution of the RF spectrum and optical spectrum with current is compared. The different mode-locked regimes are shown to be associated with different spectral and temporal shapes, ranging from 1.3 to 6 ps. This point is discussed by introducing the existence of two different supermodes. Repetition rate evolution and timing jitter increase is attributed to the coupling between the dominant and the secondary supermodes.

  19. Meaningful Words and Non-Words Repetitive Articulatory Rate (Oral Diadochokinesis) in Persian Speaking Children.

    Science.gov (United States)

    Zamani, Peyman; Rezai, Hossein; Garmatani, Neda Tahmasebi

    2017-08-01

    Repetitive articulatory rate or Oral Diadochokinesis (oral-DDK) shows a guideline for appraisal and diagnosis of subjects with oral-motor disorder. Traditionally, meaningless words repetition has been utilized in this task and preschool children have challenges with them. Therefore, we aimed to determine some meaningful words in order to test oral-DDK in Persian speaking preschool children. Participants were 142 normally developing children, (age range 4-6 years), who were asked to produce /motæka, golabi/ as two meaningful Persian words and /pa-ta-ka/ as non-word in conventional oral-DDK task. We compared the time taken for 10-times fast repetitions of two meaningful Persian words and the tri-syllabic nonsense word /pa-ta-ka/. Praat software was used to calculate the average time that subjects took to produce the target items. In 4-5 year old children, [Formula: see text] of time taken for 10-times repetitions of /pa-ta-ka, motæka, golabi/ were [Formula: see text], and [Formula: see text] seconds respectively, and in 5-6 year old children were [Formula: see text], and [Formula: see text] seconds respectively. Findings showed that the main effect of type of words on oral diadochokinesis was significant ([Formula: see text]). Children repeated meaningful words /motæka, golabi/ faster than the non-word /pa-ta-ka/. Sex and age factors had no effect on time taken for repetition of oral-DDK test. It is suggested that Speech Therapists can use meaningful words to facilitate oral-DDK test for children.

  20. Optically stabilized Erbium fiber frequency comb with hybrid mode-locking and a broad tunable range of repetition rate.

    Science.gov (United States)

    Yang, Honglei; Wu, Xuejian; Zhang, Hongyuan; Zhao, Shijie; Yang, Lijun; Wei, Haoyun; Li, Yan

    2016-12-01

    We present an optically stabilized Erbium fiber frequency comb with a broad repetition rate tuning range based on a hybrid mode-locked oscillator. We lock two comb modes to narrow-linewidth reference lasers in turn to investigate the best performance of control loops. The control bandwidth of fast and slow piezoelectric transducers reaches 70 kHz, while that of pump current modulation with phase-lead compensation is extended to 32 kHz, exceeding laser intrinsic response. Eventually, simultaneous lock of both loops is realized to totally phase-stabilize the comb, which will facilitate precision dual-comb spectroscopy, laser ranging, and timing distribution. In addition, a 1.8-MHz span of the repetition rate is achieved by an automatic optical delay line that is helpful in manufacturing a secondary comb with a similar repetition rate. The oscillator is housed in a homemade temperature-controlled box with an accuracy of ±0.02  K, which not only keeps high signal-to-noise ratio of the beat notes with reference lasers, but also guarantees self-starting at the same mode-locking every time.

  1. Highly efficient, versatile, self-Q-switched, high-repetition-rate microchip laser generating Ince–Gaussian modes for optical trapping

    Energy Technology Data Exchange (ETDEWEB)

    Jun Dong; Yu He; Xiao Zhou; Shengchuang Bai [Department of Electronics Engineering, School of Information Science and Engineering, Xiamen, 361005 (China)

    2016-03-31

    Lasers operating in the Ince-Gaussian (IG) mode have potential applications for optical manipulation of microparticles and formation of optical vortices, as well as for optical trapping and optical tweezers. Versatile, self-Q-switched, high-peak-power, high-repetition-rate Cr, Nd:YAG microchip lasers operating in the IG mode are implemented under tilted, tightly focused laser-diode pumping. An average output power of over 2 W is obtained at an absorbed pump power of 6.4 W. The highest optical-to-optical efficiency of 33.2% is achieved at an absorbed pump power of 3.9 W. Laser pulses with a pulse energy of 7.5 μJ, pulse width of 3.5 ns and peak power of over 2 kW are obtained. A repetition rate up to 335 kHz is reached at an absorbed pump power of 5.8 W. Highly efficient, versatile, IG-mode lasers with a high repetition rate and a high peak power ensure a better flexibility in particle manipulation and optical trapping. (control of laser radiation parameters)

  2. Design of a high repetition rate S-band photocathode gun

    International Nuclear Information System (INIS)

    Han Janghui; Cox, Matthew; Huang, Houcheng; Pande, Shivaji

    2011-01-01

    Photocathode RF guns have been developed in many laboratories for generating high quality electron beams for free-electron lasers based on linear accelerators. Such guns can generate electron beams with an exceptionally high peak current as well as a small transverse emittance. Their applications have been recently expanded for ultrafast electron diffraction, coherent terahertz radiation, and X-ray or γ-ray radiation by Compton scattering. In this paper, we design an S-band normal-conducting gun with capabilities of high quality beam generation and high repetition rate operation. The RF design and thermal analysis of the gun cavity and coupler are introduced. Optimal position of the gun focusing solenoid for low emittance beam generation is found by performing particle tracking simulations. Then, the gun system is designed to be able to afford the optimal solenoid position. The cooling-water channel surrounding the gun cavity and coupler is designed and analyzed numerically. The pressure in the gun is simulated with a vacuum model containing the detailed inner structure of the gun. An injector for a free-electron laser application is designed by using this gun and the beam dynamics simulation is shown. A cold test with a prototype gun for confirmation of the RF design is reported. - Highlights: → We design an S-band gun for low emittance beam generation and high repetition rate operation. → The RF design and thermal analysis of the gun cavity and coupler are studied. → An FEL injector is designed by using this gun and the beam dynamics simulation is shown. → A cold test with a prototype gun for confirmation of the RF design is reported.

  3. Studies of a Linac Driver for a High Repetition Rate X-Ray FEL

    International Nuclear Information System (INIS)

    Venturini, M.; Corlett, J.; Doolittle, L.; Filippetto, D.; Papadopoulos, C.; Penn, G.; Prosnitz, D.; Qiang, J.; Reinsch, M.; Ryne, R.; Sannibale, F.; Staples, J.; Wells, R.; Wurtele, J.; Zolotorev, M.; Zholents, A.

    2011-01-01

    We report on on-going studies of a superconducting CW linac driver intended to support a high repetition rate FEL operating in the soft x-rays spectrum. We present a pointdesign for a 1.8 GeV machine tuned for 300 pC bunches and delivering low-emittance, low-energy spread beams as needed for the SASE and seeded beamlines.

  4. Environmentally stable picosecond Yb fiber laser with low repetition rate

    Science.gov (United States)

    Baumgartl, M.; Abreu-Afonso, J.; Díez, A.; Rothhardt, M.; Limpert, J.; Tünnermann, A.

    2013-04-01

    A SESAM-mode-locked, all-polarization-maintaining Ytterbium fiber laser producing picosecond pulses with narrow spectral bandwidth is presented. A simple linear all-fiber cavity without dispersion compensation is realized using a uniform fiber Bragg grating (FBG). Different cavity lengths are investigated and repetition rates down to 0.7 MHz are obtained. Bandwidth and pulse duration of the output pulses are mainly determined by the choice of FBG. Pulses between 30 and 200 ps are generated employing different FBGs with bandwidths between 17 and 96 pm. The experimental results are in good agreement with numerical simulations. The laser holds great potential for simple amplification setups without pulse picking.

  5. High speed surface cleaning by a high repetition rated TEA-CO2 laser

    International Nuclear Information System (INIS)

    Tsunemi, Akira; Hirai, Ryo; Hagiwara, Kouji; Nagasaka, Keigo; Tashiro, Hideo

    1994-01-01

    We demonstrated the feasibility of high speed cleaning of solid surfaces by the laser ablation technique using a TEA-CO 2 laser. The laser pulses with the repetition rate of 1 kHz were applied to paint, rust, moss and dirt attached on the surfaces. The attachments were effectively removed without the damage of bulk surfaces by the irradiation of line-focused sequential pulses with an energy of 300 mJ/pulse. A cleaning rate reached to 17 m 2 /hour for the case of paint removal from iron surfaces. (author)

  6. Phase-stable, multi-µJ femtosecond pulses from a repetition-rate tunable Ti:Sa-oscillator-seeded Yb-fiber amplifier

    Science.gov (United States)

    Saule, T.; Holzberger, S.; De Vries, O.; Plötner, M.; Limpert, J.; Tünnermann, A.; Pupeza, I.

    2017-01-01

    We present a high-power, MHz-repetition-rate, phase-stable femtosecond laser system based on a phase-stabilized Ti:Sa oscillator and a multi-stage Yb-fiber chirped-pulse power amplifier. A 10-nm band around 1030 nm is split from the 7-fs oscillator output and serves as the seed for subsequent amplification by 54 dB to 80 W of average power. The µJ-level output is spectrally broadened in a solid-core fiber and compressed to 30 fs with chirped mirrors. A pulse picker prior to power amplification allows for decreasing the repetition rate from 74 MHz by a factor of up to 4 without affecting the pulse parameters. To compensate for phase jitter added by the amplifier to the feed-forward phase-stabilized seeding pulses, a self-referencing feed-back loop is implemented at the system output. An integrated out-of-loop phase noise of less than 100 mrad was measured in the band from 0.4 Hz to 400 kHz, which to the best of our knowledge corresponds to the highest phase stability ever demonstrated for high-power, multi-MHz-repetition-rate ultrafast lasers. This system will enable experiments in attosecond physics at unprecedented repetition rates, it offers ideal prerequisites for the generation and field-resolved electro-optical sampling of high-power, broadband infrared pulses, and it is suitable for phase-stable white light generation.

  7. High repetition rate driver circuit for modulation of injection lasers

    International Nuclear Information System (INIS)

    Dornan, B.R.; Goel, J.; Wolkstein, H.J.

    1981-01-01

    An injection laser modulator comprises a self-biased field effect transistor (FET) and an injection laser to provide a quiescent state during which lasing of the injection laser occurs in response to a high repetition rate signal of pulse coded modulation (pcm). The modulator is d.c. coupled to an input pulse source of pcm rendering it compatible with an input pulse referenced to ground and not being subject to voltage level shifting of the input pulse. The modulator circuit in its preferred and alternate embodiments provides various arrangements for high impedance input and low impedance output matching. In addition, means are provided for adjusting the bias of the FET as well as the bias of the injection laser

  8. Repetition Blindness: Out of Sight or Out of Mind?

    Science.gov (United States)

    Morris, Alison L.; Harris, Catherine L.

    2004-01-01

    Does repetition blindness represent a failure of perception or of memory? In Experiment 1, participants viewed rapid serial visual presentation (RSVP) sentences. When critical words (C1 and C2) were orthographically similar, C2 was frequently omitted from serial report; however, repetition priming for C2 on a postsentence lexical decision task was…

  9. Improved repetition rate mixed isotope CO{sub 2} TEA laser

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, D. B., E-mail: dbctechnology@earthlink.net [DBC Technology Corp., 4221 Mesa St, Torrance, California 90505 (United States)

    2014-09-15

    A compact CO{sub 2} TEA laser has been developed for remote chemical detection that operates at a repetition rate of 250 Hz. It emits 700 mJ/pulse at 10.6 μm in a multimode beam with the {sup 12}C{sup 16}O{sub 2} isotope. With mixed {sup 12}C{sup 16}O{sub 2} plus {sup 13}C{sup 16}O{sub 2} isotopes it emits multiple lines in both isotope manifolds to improve detection of a broad range of chemicals. In particular, output pulse energies are 110 mJ/pulse at 9.77 μm, 250 mJ/pulse at 10 μm, and 550 mJ/pulse at 11.15 μm, useful for detection of the chemical agents Sarin, Tabun, and VX. Related work shows capability for long term sealed operation with a catalyst and an agile tuner at a wavelength shift rate of 200 Hz.

  10. Investigation on repetition rate and pulse duration influences on ablation efficiency of metals using a high average power Yb-doped ultrafast laser

    Directory of Open Access Journals (Sweden)

    Lopez J.

    2013-11-01

    Full Text Available Ultrafast lasers provide an outstanding processing quality but their main drawback is the low removal rate per pulse compared to longer pulses. This limitation could be overcome by increasing both average power and repetition rate. In this paper, we report on the influence of high repetition rate and pulse duration on both ablation efficiency and processing quality on metals. All trials have been performed with a single tunable ultrafast laser (350 fs to 10ps.

  11. Performance of a high repetition pulse rate laser system for in-gas-jet laser ionization studies with the Leuven laser ion source LISOL

    International Nuclear Information System (INIS)

    Ferrer, R.; Sonnenschein, V.T.; Bastin, B.; Franchoo, S.; Huyse, M.; Kudryavtsev, Yu.; Kron, T.; Lecesne, N.; Moore, I.D.; Osmond, B.; Pauwels, D.; Radulov, D.; Raeder, S.; Rens, L.

    2012-01-01

    The laser ionization efficiency of the Leuven gas cell-based laser ion source was investigated under on- and off-line conditions using two distinctly different laser setups: a low-repetition rate dye laser system and a high-repetition rate Ti:sapphire laser system. A systematic study of the ion signal dependence on repetition rate and laser pulse energy was performed in off-line tests using stable cobalt and copper isotopes. These studies also included in-gas-jet laser spectroscopy measurements on the hyperfine structure of 63 Cu. A final run under on-line conditions in which the radioactive isotope 59 Cu (T 1/2 = 81.5 s) was produced, showed a comparable yield of the two laser systems for in-gas-cell ionization. However, a significantly improved time overlap by using the high-repetition rate laser system for in-gas-jet ionization was demonstrated by an increase of the overall duty cycle, and at the same time, pointed to the need for a better shaped atomic jet to reach higher ionization efficiencies.

  12. Repetition and the Concept of Repetition

    Directory of Open Access Journals (Sweden)

    Arne Grøn

    2013-11-01

    Full Text Available This paper offers a description of the meaning of the category of repetition. Firstly, it is pointed out that Constantin uses repetition as a concept that means the creation of epochs; the passing from Greece to Modernity is accomplished distinguishing between recollection, a concept that looks back to the past, and repetition, a concept that looks forward to future. Secondly, it is showed that the category of repetition, as a religious category, relates with what Climacus calls “ethic despair” and with what Vigilius calls “second ethics”; it is through repetition that it can be understood that sin finds its place in ethics and these shows the tension between it and dogmatics. And thirdly, it is showed that the descovery of the new category of repetition is a rediscovery of what Kierkegaard calls category of spirit; repetition has for its object the individuality, and coming to be oneself is what Kierkegaard undertands as liberty. At the end of the paper it is questioned if the category of repetition is inconsistent with the book Repetition.

  13. Upper arm elevation and repetitive shoulder movements: a general population job exposure matrix based on expert ratings and technical measurements.

    Science.gov (United States)

    Dalbøge, Annett; Hansson, Gert-Åke; Frost, Poul; Andersen, Johan Hviid; Heilskov-Hansen, Thomas; Svendsen, Susanne Wulff

    2016-08-01

    We recently constructed a general population job exposure matrix (JEM), The Shoulder JEM, based on expert ratings. The overall aim of this study was to convert expert-rated job exposures for upper arm elevation and repetitive shoulder movements to measurement scales. The Shoulder JEM covers all Danish occupational titles, divided into 172 job groups. For 36 of these job groups, we obtained technical measurements (inclinometry) of upper arm elevation and repetitive shoulder movements. To validate the expert-rated job exposures against the measured job exposures, we used Spearman rank correlations and the explained variance[Formula: see text] according to linear regression analyses (36 job groups). We used the linear regression equations to convert the expert-rated job exposures for all 172 job groups into predicted measured job exposures. Bland-Altman analyses were used to assess the agreement between the predicted and measured job exposures. The Spearman rank correlations were 0.63 for upper arm elevation and 0.64 for repetitive shoulder movements. The expert-rated job exposures explained 64% and 41% of the variance of the measured job exposures, respectively. The corresponding calibration equations were y=0.5%time+0.16×expert rating and y=27°/s+0.47×expert rating. The mean differences between predicted and measured job exposures were zero due to calibration; the 95% limits of agreement were ±2.9% time for upper arm elevation >90° and ±33°/s for repetitive shoulder movements. The updated Shoulder JEM can be used to present exposure-response relationships on measurement scales. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. R-rated film viewing and adolescent smoking.

    Science.gov (United States)

    Laugesen, Murray; Scragg, Robert; Wellman, Robert J; DiFranza, Joseph R

    2007-12-01

    As smoking is very common in R-rated films, we sought to determine if viewing R-rated films is associated with adolescent smoking. Three annual cross-sectional surveys conducted of 88,505 Year 10 students of largely European, Maori, Asian or Pacific Islander ethnicity in secondary schools in New Zealand between 2002 and 2004. Outcomes of interest were: intention to smoke among never smokers; past experimentation with smoking among current non-smokers; current smoking status; and current frequency of smoking. Dose-response relationships were observed between the frequency of viewing R-rated films and all outcome measures controlling for age, gender, ethnicity, peer smoking, parental smoking, socioeconomic status, pocket money and household smoking rules. Compared to never viewing R-rated films, viewing at least weekly nearly tripled the relative risk (2.81; 95% confidence interval 2.57, 3.09) of never smokers being susceptible to smoking, and more than doubled the risk of both past experimentation (2.28; 95% CI 2.12, 2.45) and smoking>/=monthly (2.31; 95% CI 2.10, 2.54). Each of these risks was seen across all ethnic groups. Our results extend the association that has been demonstrated between viewing R-rated films and current smoking in American youth by demonstrating the same association in youth of different ethnic and cultural backgrounds in New Zealand.

  15. Elemental redistribution behavior in tellurite glass induced by high repetition rate femtosecond laser irradiation

    International Nuclear Information System (INIS)

    Teng, Yu; Zhou, Jiajia; Khisro, Said Nasir; Zhou, Shifeng; Qiu, Jianrong

    2014-01-01

    Highlights: • Abnormal elements redistribution behavior was observed in tellurite glass. • The refractive index and Raman intensity distribution changed significantly. • The relative glass composition remained unchanged while the glass density changed. • First time report on the abnormal element redistribution behavior in glass. • The glass network structure determines the elemental redistribution behavior. - Abstract: The success in the fabrication of micro-structures in glassy materials using femtosecond laser irradiation has proved its potential applications in the construction of three-dimensional micro-optical components or devices. In this paper, we report the elemental redistribution behavior in tellurite glass after the irradiation of high repetition rate femtosecond laser pulses. The relative glass composition remained unchanged while the glass density changed significantly, which is quite different from previously reported results about the high repetition rate femtosecond laser induced elemental redistribution in silicate glasses. The involved mechanism is discussed with the conclusion that the glass network structure plays the key role to determine the elemental redistribution. This observation not only helps to understand the interaction process of femtosecond laser with glassy materials, but also has potential applications in the fabrication of micro-optical devices

  16. Bright high-repetition-rate source of narrowband extreme-ultraviolet harmonics beyond 22 eV

    Energy Technology Data Exchange (ETDEWEB)

    Wang, He [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Xu, Yiming [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Ulonska, Stefan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Robinson, Joseph S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Ranitovic, Predrag [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Kaindl, Robert A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division

    2015-06-11

    Novel table-top sources of extreme-ultraviolet light based on high-harmonic generation yield unique insight into the fundamental properties of molecules, nanomaterials or correlated solids, and enable advanced applications in imaging or metrology. Extending high-harmonic generation to high repetition rates portends great experimental benefits, yet efficient extreme-ultraviolet conversion of correspondingly weak driving pulses is challenging. In this article, we demonstrate a highly-efficient source of femtosecond extreme-ultraviolet pulses at 50-kHz repetition rate, utilizing the ultraviolet second-harmonic focused tightly into Kr gas. In this cascaded scheme, a photon flux beyond ≈3 × 1013 s-1 is generated at 22.3 eV, with 5 × 10-5 conversion efficiency that surpasses similar harmonics directly driven by the fundamental by two orders-of-magnitude. The enhancement arises from both wavelength scaling of the atomic dipole and improved spatio-temporal phase matching, confirmed by simulations. Finally, spectral isolation of a single 72-meV-wide harmonic renders this bright, 50-kHz extreme-ultraviolet source a powerful tool for ultrafast photoemission, nanoscale imaging and other applications.

  17. Development of ultra high speed photographic system using high repetition rate visible laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Byung Hun; Kim, Sung Ho; Kim, Jung Bog; Lim, Chang Hwan; Cha, Hyung Ki; Song, Kyu Seok; Lee, Byung Deok; Rhi, Jong Hoon; Baik, Dae Hyun; Han, Jae Min; Rho, Si Pyo; Lee, Byung Cheol; Jeong, Do Yung; Choi, An Seong; Jeong, Chan Ik; Park, Dae Ung; Jeong, Sung Min; Lee, Sang Kil; Kim, Heon Jun; Jang, Rae gak; Jo, Do Hun; Park, Min Young

    1992-12-01

    The goal of this project is to develop and commercialize a high speed photographic system equipped with a high repetition rate visible laser. The developed system provides the characteristics of high time resolution and large number of frames. The system consists of 10 W air cooled CVL or a 30 W water cooled CVL, a rotating drum-type high speed camera with the framing rate of 35,000 fps, and a automatic control device. The system has the performance of 10 nsec time resolution, 35,000 fps framing rate, and 250 picture frames. The high speed photographic systems are widely applied to the fields such as high-efficient engine development, high-speed vibration analysis, shock wave propagation study, flow visualization analysis, weapon development, etc. (Author)

  18. Repetition rates in heavy ion beam driven fusion reactors

    Science.gov (United States)

    Peterson, Robert R.

    1986-01-01

    The limits on the cavity gas density required for beam propagation and condensation times for material vaporized by target explosions can determine the maximum repetition rate of Heavy Ion Beam (HIB) driven fusion reactors. If the ions are ballistically focused onto the target, the cavity gas must have a density below roughly 10-4 torr (3×1012 cm-3) at the time of propagation; other propagation schemes may allow densities as high as 1 torr or more. In some reactor designs, several kilograms of material may be vaporized off of the target chamber walls by the target generated x-rays, raising the average density in the cavity to 100 tor or more. A one-dimensional combined radiation hydrodynamics and vaporization and condensation computer code has been used to simulate the behavior of the vaporized material in the target chambers of HIB fusion reactors.

  19. Repetition rates in heavy ion beam driven fusion reactors

    International Nuclear Information System (INIS)

    Peterson, R.R.

    1986-01-01

    The limits on the cavity gas density required for beam propagation and condensation times for material vaporized by target explosions can determine the maximum repetition rate of Heavy Ion Beam (HIB) driven fusion reactors. If the ions are ballistically focused onto the target, the cavity gas must have a density below roughly 10 -4 torr (3 x 10 12 cm -3 ) at the time of propagation; other propagation schemes may allow densities as high as 1 torr or more. In some reactor designs, several kilograms of material may be vaporized off of the target chamber walls by the target generated x-rays, raising the average density in the cavity to 100 tor or more. A one-dimensional combined radiation hydrodynamics and vaporization and condensation computer code has been used to simulate the behavior of the vaporized material in the target chambers of HIB fusion reactors

  20. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    Science.gov (United States)

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. High-average-power 2 μm few-cycle optical parametric chirped pulse amplifier at 100 kHz repetition rate.

    Science.gov (United States)

    Shamir, Yariv; Rothhardt, Jan; Hädrich, Steffen; Demmler, Stefan; Tschernajew, Maxim; Limpert, Jens; Tünnermann, Andreas

    2015-12-01

    Sources of long wavelengths few-cycle high repetition rate pulses are becoming increasingly important for a plethora of applications, e.g., in high-field physics. Here, we report on the realization of a tunable optical parametric chirped pulse amplifier at 100 kHz repetition rate. At a central wavelength of 2 μm, the system delivered 33 fs pulses and a 6 W average power corresponding to 60 μJ pulse energy with gigawatt-level peak powers. Idler absorption and its crystal heating is experimentally investigated for a BBO. Strategies for further power scaling to several tens of watts of average power are discussed.

  2. A mode-locked external-cavity quantum-dot laser with a variable repetition rate

    International Nuclear Information System (INIS)

    Wu Jian; Jin Peng; Li Xin-Kun; Wei Heng; Wu Yan-Hua; Wang Fei-Fei; Chen Hong-Mei; Wu Ju; Wang Zhan-Guo

    2013-01-01

    A mode-locked external-cavity laser emitting at 1.17-μm wavelength using an InAs/GaAs quantum-dot gain medium and a discrete semiconductor saturable absorber mirror is demonstrated. By changing the external-cavity length, repetition rates of 854, 912, and 969 MHz are achieved respectively. The narrowest −3-dB radio-frequency linewidth obtained is 38 kHz, indicating that the laser is under stable mode-locking operation. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  3. High-power 355 nm ultraviolet lasers operating at ultrahigh repetition rate

    International Nuclear Information System (INIS)

    Chen, H; Liu, Q; Yan, P; Gong, M

    2013-01-01

    In this letter, we demonstrate a novel 355 nm ultraviolet (UV) laser operating at ultrahigh repetition rate from 300 kHz to 1 MHz. The hybrid fiber-MOPA–bulk amplifiers based IR source exhibits a high average power of 105 W with near-diffraction-limited beam quality, narrow linewidth and high polarization extinction ratio. Two-cascaded LBO crystals are employed for high efficiency frequency tripling, and a maximum 43.7 W of average UV power is achieved at 400 kHz, corresponding to a conversion efficiency as high as 41.6%. The pulse duration of the UV pulse can be tuned from 5 to 10 ns with good pulse peak stability (better than 2.2% (RMS)). (letter)

  4. A 7.8 kV nanosecond pulse generator with a 500 Hz repetition rate

    Science.gov (United States)

    Lin, M.; Liao, H.; Liu, M.; Zhu, G.; Yang, Z.; Shi, P.; Lu, Q.; Sun, X.

    2018-04-01

    Pseudospark switches are widely used in pulsed power applications. In this paper, we present the design and performance of a 500 Hz repetition rate high-voltage pulse generator to drive TDI-series pseudospark switches. A high-voltage pulse is produced by discharging an 8 μF capacitor through a primary windings of a setup isolation transformer using a single metal-oxide-semiconductor field-effect transistor (MOSFET) as a control switch. In addition, a self-break spark gap is used to steepen the pulse front. The pulse generator can deliver a high-voltage pulse with a peak trigger voltage of 7.8 kV, a peak trigger current of 63 A, a full width at half maximum (FWHM) of ~30 ns, and a rise time of 5 ns to the trigger pin of the pseudospark switch. During burst mode operation, the generator achieved up to a 500 Hz repetition rate. Meanwhile, we also provide an AC heater power circuit for heating a H2 reservoir. This pulse generator can be used in circuits with TDI-series pseudospark switches with either a grounded cathode or with a cathode electrically floating operation. The details of the circuits and their implementation are described in the paper.

  5. The effect of laser repetition rate on the LASiS synthesis of biocompatible silver nanoparticles in aqueous starch solution

    Directory of Open Access Journals (Sweden)

    Zamiri R

    2013-01-01

    Full Text Available Reza Zamiri,1 Azmi Zakaria,1,* Hossein Abbastabar Ahangar,2 Majid Darroudi,3 Golnoosh Zamiri,1 Zahid Rizwan,1 Gregor PC Drummen4,* 1Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang, Selangor, Malaysia; 2Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, Selangor Darul Ehsan, Malaysia; 3Advanced Materials and Nanotechnology Laboratory, Institute of Advanced Technology (ITMA, Universiti Putra Malaysia, Serdang, Selangor, Malaysia; 4Bionanoscience and Bio-Imaging Program, Cellular Stress and Ageing Program, Bio&Nano-Solutions, Düsseldorf, Germany*These authors contributed to this work equallyAbstract: Laser ablation-based nanoparticle synthesis in solution is rapidly becoming popular, particularly for potential biomedical and life science applications. This method promises one pot synthesis and concomitant bio-functionalization, is devoid of toxic chemicals, does not require complicated apparatus, can be combined with natural stabilizers, is directly biocompatible, and has high particle size uniformity. Size control and reduction is generally determined by the laser settings; that the size and size distribution scales with laser fluence is well described. Conversely, the effect of the laser repetition rate on the final nanoparticle product in laser ablation is less well-documented, especially in the presence of stabilizers. Here, the influence of the laser repetition rate during laser ablation synthesis of silver nanoparticles in the presence of starch as a stabilizer was investigated. The increment of the repetition rate does not negatively influence the ablation efficiency, but rather shows increased productivity, causes a red-shift in the plasmon resonance peak of the silver–starch nanoparticles, an increase in mean particle size and size distribution, and a distinct lack of agglomerate formation. Optimal results were achieved at 10 Hz repetition rate, with a mean particle size of ~10 nm and a

  6. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  7. Power scaling of supercontinuum seeded megahertz-repetition rate optical parametric chirped pulse amplifiers.

    Science.gov (United States)

    Riedel, R; Stephanides, A; Prandolini, M J; Gronloh, B; Jungbluth, B; Mans, T; Tavella, F

    2014-03-15

    Optical parametric chirped-pulse amplifiers with high average power are possible with novel high-power Yb:YAG amplifiers with kW-level output powers. We demonstrate a compact wavelength-tunable sub-30-fs amplifier with 11.4 W average power with 20.7% pump-to-signal conversion efficiency. For parametric amplification, a beta-barium borate crystal is pumped by a 140 W, 1 ps Yb:YAG InnoSlab amplifier at 3.25 MHz repetition rate. The broadband seed is generated via supercontinuum generation in a YAG crystal.

  8. Efficacy Of The Repetitions In Reserve-Based Rating Of Perceived Exertion For The Bench Press In Experienced And Novice Benchers.

    Science.gov (United States)

    Ormsbee, Michael J; Carzoli, Joseph P; Klemp, Alex; Allman, Brittany R; Zourdos, Michael C; Kim, Jeong-Su; Panton, Lynn B

    2017-03-13

    Autoregulation (AR) is the practice of adjusting training variables in response to athlete feedback. One component of AR postulated to enhance resistance training adaptations involves implementing a resistance training-specific rating of perceived exertion (RPE) scale measuring repetitions in reserve (RIR). The purpose of this study was to examine the efficacy of this method using the bench press exercise. Twenty-seven college-aged men were assigned to one of two groups based upon training age: experience benchers (EB) (n=14, training age: 4.7±2.0 yrs) and novice benchers (NB) (n=13, training age: 1.1±0.6 yrs). Subjects performed one-repetition maximum (1RM) followed by single-repetition sets with loads corresponding to 60, 75, and 90% of 1RM and an 8-repetition set at 70% 1RM. Subjects reported a corresponding RPE, based on RIR, for every set. Average velocity was recorded for each single-repetition set along with the first and last repetitions of the 8-repetition set at 70% 1RM. Average velocity at 100% of 1RM in EB was slower (0.14±0.04 m[BULLET OPERATOR]s) compared to NB (0.20±0.05 m[BULLET OPERATOR]s) (pvelocity or RPE at any other intensity. Both EB (r=0.85, pvelocity and RPE at all intensities. Our findings suggest that the RIR-based RPE scale may be an efficacious approach for AR of bench press training load and volume in college-aged men.

  9. Parameters of a trigatron-driven low-pulse-repetition-rate TEA CO2 laser preionised by a surface corona discharge

    International Nuclear Information System (INIS)

    Aram, M; Shabanzadeh, M; Mansori, F; Behjat, A

    2007-01-01

    The design of a TEA CO 2 laser with UV preionisation by a surface corona discharge is described and the dependences of its average output energy on the gas-flow rate, discharge voltage and pulse repetition rate are presented. The scheme of the electric circuit and the geometry of the pre-ionisation system are considered. The electric circuit is designed to produce only impulse voltage difference between the laser electrodes. The triggering system of the trigatron is used to prevent the appearance of the arc. The dependences of the current, voltage and average output energy on the gas-mixture composition and applied voltages at a low pulse repetition rate are presented. The central output wavelength of the laser was measured with an IR spectrometer. Lasing at two adjacent vibrational-rotational transitions of the CO 2 molecule was observed, which demonstrates the possibility of simultaneous lasing at several lines. (lasers)

  10. Fluorescence fluctuation of Rhodamine 6G dye for high repetition rate laser excitation

    International Nuclear Information System (INIS)

    Singh, Nageshwar; Patel, Hemant K.; Dixit, S.K.; Vora, H.S.

    2013-01-01

    In this paper, fluorescence from Rhodamine 6G dye for stationary and flowing liquid medium, excited by copper vapor laser, operating at 6 kHz pulse repetition frequency, was investigated. Large fluctuations in spectral width (about 5 nm) and spectral intensity in the fluorescence from stationary dye solution were observed, while fluctuations in the spectral width diminish in a flowing dye medium. However, this increases spectral intensity and slightly red shifts the fluorescence peak emission wavelength. Theoretical analysis was carried out to explain the observed results by incorporating the temperature induced refractive index, beam deflection and spectral variation in stationary dye solution. Numerical analysis of thermal load and contour of temperature in the optical pumped region inside the dye cell in stationary, 0.2 and 1.5 m/s flow velocity was also investigated to support our analysis. - Highlights: ► High repetition rate excitation generates inhomogeneity in the gain medium. ► Fluorescence of Rhodamine 6G in stationary and flowing medium was carried out. ► Fluorescence fluctuations lessen in flowing medium in contrast to stationary medium. ► Our theoretical and numerical analysis enlightens the experimented outcome trend.

  11. Subjective duration distortions mirror neural repetition suppression.

    Science.gov (United States)

    Pariyadath, Vani; Eagleman, David M

    2012-01-01

    Subjective duration is strongly influenced by repetition and novelty, such that an oddball stimulus in a stream of repeated stimuli appears to last longer in duration in comparison. We hypothesize that this duration illusion, called the temporal oddball effect, is a result of the difference in expectation between the oddball and the repeated stimuli. Specifically, we conjecture that the repeated stimuli contract in duration as a result of increased predictability; these duration contractions, we suggest, result from decreased neural response amplitude with repetition, known as repetition suppression. Participants viewed trials consisting of lines presented at a particular orientation (standard stimuli) followed by a line presented at a different orientation (oddball stimulus). We found that the size of the oddball effect correlates with the number of repetitions of the standard stimulus as well as the amount of deviance from the oddball stimulus; both of these results are consistent with a repetition suppression hypothesis. Further, we find that the temporal oddball effect is sensitive to experimental context--that is, the size of the oddball effect for a particular experimental trial is influenced by the range of duration distortions seen in preceding trials. Our data suggest that the repetition-related duration contractions causing the oddball effect are a result of neural repetition suppression. More generally, subjective duration may reflect the prediction error associated with a stimulus and, consequently, the efficiency of encoding that stimulus. Additionally, we emphasize that experimental context effects need to be taken into consideration when designing duration-related tasks.

  12. Subjective duration distortions mirror neural repetition suppression.

    Directory of Open Access Journals (Sweden)

    Vani Pariyadath

    Full Text Available Subjective duration is strongly influenced by repetition and novelty, such that an oddball stimulus in a stream of repeated stimuli appears to last longer in duration in comparison. We hypothesize that this duration illusion, called the temporal oddball effect, is a result of the difference in expectation between the oddball and the repeated stimuli. Specifically, we conjecture that the repeated stimuli contract in duration as a result of increased predictability; these duration contractions, we suggest, result from decreased neural response amplitude with repetition, known as repetition suppression.Participants viewed trials consisting of lines presented at a particular orientation (standard stimuli followed by a line presented at a different orientation (oddball stimulus. We found that the size of the oddball effect correlates with the number of repetitions of the standard stimulus as well as the amount of deviance from the oddball stimulus; both of these results are consistent with a repetition suppression hypothesis. Further, we find that the temporal oddball effect is sensitive to experimental context--that is, the size of the oddball effect for a particular experimental trial is influenced by the range of duration distortions seen in preceding trials.Our data suggest that the repetition-related duration contractions causing the oddball effect are a result of neural repetition suppression. More generally, subjective duration may reflect the prediction error associated with a stimulus and, consequently, the efficiency of encoding that stimulus. Additionally, we emphasize that experimental context effects need to be taken into consideration when designing duration-related tasks.

  13. Tunable dispersion compensator based on uniform fiber Bragg grating and its application to tunable pulse repetition-rate multiplication.

    Science.gov (United States)

    Han, Young-Geun; Lee, Sang

    2005-11-14

    A new technique to control the chromatic dispersion of a uniform fiber Bragg grating based on the symmetrical bending is proposed and experimentally demonstrated. The specially designed two translation stages with gears and a sawtooth wheel can simultaneously induce the tension and compression strain corresponding to the bending direction. The tension and compression strain can effectively control the chirp ratio along the fiber grating attached on a flexible cantilever beam and consequently the dispersion value without the center wavelength shift. We successfully achieve the wide tuning range of chromatic dispersion without the center wavelength shift, which is less than 0.02 nm. We also reduce the group delay ripple as low as ~+/-5 ps. And we also demonstrate the application of the proposed tunable dispersion compensation technique to the tunable pulse repetition-rate multiplication and obtain high-quality pulses at repetition rates of 20 ~ 40 GHz.

  14. 2 ~ 5 times tunable repetition-rate multiplication of a 10 GHz pulse source using a linearly tunable, chirped fiber Bragg grating.

    Science.gov (United States)

    Lee, Ju Han; Chang, You; Han, Young-Geun; Kim, Sang; Lee, Sang

    2004-08-23

    We experimentally demonstrate a simple scheme for the tunable pulse repetition-rate multiplication based on the fractional Talbot effect in a linearly tunable, chirped fiber Bragg grating (FBG). The key component in this scheme is our linearly tunable, chirped FBG with no center wavelength shift, which was fabricated with the S-bending method using a uniform FBG. By simply tuning the group velocity dispersion of the chirped FBG, we readily multiply an original 8.5 ps, 10 GHz soliton pulse train by a factor of 2 ~ 5 to obtain high quality pulses at repetition-rates of 20 ~ 50 GHz without significantly changing the system configuration.

  15. LASERS: Parameters of a trigatron-driven low-pulse-repetition-rate TEA CO2 laser preionised by a surface corona discharge

    Science.gov (United States)

    Aram, M.; Behjat, A.; Shabanzadeh, M.; Mansori, F.

    2007-01-01

    The design of a TEA CO2 laser with UV preionisation by a surface corona discharge is described and the dependences of its average output energy on the gas-flow rate, discharge voltage and pulse repetition rate are presented. The scheme of the electric circuit and the geometry of the pre-ionisation system are considered. The electric circuit is designed to produce only impulse voltage difference between the laser electrodes. The triggering system of the trigatron is used to prevent the appearance of the arc. The dependences of the current, voltage and average output energy on the gas-mixture composition and applied voltages at a low pulse repetition rate are presented. The central output wavelength of the laser was measured with an IR spectrometer. Lasing at two adjacent vibrational-rotational transitions of the CO2 molecule was observed, which demonstrates the possibility of simultaneous lasing at several lines.

  16. Gigahertz repetition rate, sub-femtosecond timing jitter optical pulse train directly generated from a mode-locked Yb:KYW laser.

    Science.gov (United States)

    Yang, Heewon; Kim, Hyoji; Shin, Junho; Kim, Chur; Choi, Sun Young; Kim, Guang-Hoon; Rotermund, Fabian; Kim, Jungwon

    2014-01-01

    We show that a 1.13 GHz repetition rate optical pulse train with 0.70 fs high-frequency timing jitter (integration bandwidth of 17.5 kHz-10 MHz, where the measurement instrument-limited noise floor contributes 0.41 fs in 10 MHz bandwidth) can be directly generated from a free-running, single-mode diode-pumped Yb:KYW laser mode-locked by single-wall carbon nanotube-coated mirrors. To our knowledge, this is the lowest-timing-jitter optical pulse train with gigahertz repetition rate ever measured. If this pulse train is used for direct sampling of 565 MHz signals (Nyquist frequency of the pulse train), the jitter level demonstrated would correspond to the projected effective-number-of-bit of 17.8, which is much higher than the thermal noise limit of 50 Ω load resistance (~14 bits).

  17. Emotional response to musical repetition.

    Science.gov (United States)

    Livingstone, Steven R; Palmer, Caroline; Schubert, Emery

    2012-06-01

    Two experiments examined the effects of repetition on listeners' emotional response to music. Listeners heard recordings of orchestral music that contained a large section repeated twice. The music had a symmetric phrase structure (same-length phrases) in Experiment 1 and an asymmetric phrase structure (different-length phrases) in Experiment 2, hypothesized to alter the predictability of sensitivity to musical repetition. Continuous measures of arousal and valence were compared across music that contained identical repetition, variation (related), or contrasting (unrelated) structure. Listeners' emotional arousal ratings differed most for contrasting music, moderately for variations, and least for repeating musical segments. A computational model for the detection of repeated musical segments was applied to the listeners' emotional responses. The model detected the locations of phrase boundaries from the emotional responses better than from performed tempo or physical intensity in both experiments. These findings indicate the importance of repetition in listeners' emotional response to music and in the perceptual segmentation of musical structure.

  18. HIGH REPETITION RATE MICROCHIP ER3+,YB3+:YAL3(BO34 DIODE-PUMPED LASER

    Directory of Open Access Journals (Sweden)

    K. N. Gorbachenya

    2012-01-01

    Full Text Available Diode-pumped passively Q-switched microchip Er,Yb:YAl3(BO34 laser for range-finding has been demonstrated. By using a Co2+:MgAl2O4 as a saturable absorber TEM00–mode Q-switched average output power of 315 mW was demonstrated at 1522 nm with pulse duration of 5 ns and pulse energy of 5,25 μJ at a repetition rate of 60 kHz.

  19. High voltage nanosecond generator with pulse repetition rate of 1,000 p.p.s.

    Energy Technology Data Exchange (ETDEWEB)

    Gubanov, V P; Korovin, S D; Stepchenko, A S [High Current Electronics Institute, Tomsk (Russian Federation)

    1997-12-31

    A compact high voltage nanosecond generator is described with a pulse repetition rate up to 1000 p.p.s. The generator includes a 30-Ohm coaxial forming line charged by a built-in Tesla transformer with a high coupling coefficient, and a high voltage (N{sub 2}) gas gap switch with gas blowing between the electrodes. The maximum forming line charge voltage is 450 kV, the pulse duration is about 4 ns, and its amplitude for a matched load is up to 200 kV. (author). 3 figs., 9 refs.

  20. Actual laser removal of black soiling crust from siliceous sandstone by high pulse repetition rate equipment: effects on surface morphology

    Directory of Open Access Journals (Sweden)

    Iglesias-Campos, M. A.

    2016-03-01

    Full Text Available This research project studies the role of pulse repetition rate in laser removal of black soiling crust from siliceous sandstone, and specifically, how laser fluence correlates with high pulse repetition rates in cleaning practice. The aim is to define practical cleaning processes and determine simple techniques for evaluation based on end-users’ perspective (restorers. Spot and surface tests were made using a Q-switched Nd:YAG laser system with a wide range of pulse repetition rates (5–200 Hz, systematically analysed and compared by macrophotography, portable microscope, stereomicroscope with 3D visualizing and area roughness measurements, SEM imaging and spectrophotometry. The results allow the conclusion that for operation under high pulse repetition rates the average of total energy applied per spot on a treated surface should be attendant upon fluence values in order to provide a systematic and accurate description of an actual laser cleaning intervention.En este trabajo se estudia el papel de la frecuencia de repetición en la limpieza láser de costras de contaminación sobre una arenisca silícea, y concretamente, como se relaciona fluencia y frecuencias elevadas en una limpieza real. Se pretende definir un procedimiento práctico de limpieza y determinar técnicas sencillas de evaluación desde el punto de vista de los usuarios finales (restauradores. Para el estudio se realizaron diferentes ensayos en spot y en superficie mediante un equipo Q-switched Nd:YAG con un amplio rango de frecuencias (5–200 Hz, que se analizaron y compararon sistemáticamente mediante macrofotografía, microscopio portátil, estereomicroscopio con visualización 3D y mediciones de rugosidad en área, imágenes SEM y espectrofotometría. Los resultados permiten proponer que, al trabajar con altas frecuencias, la media de la energía total depositada por spot en la superficie debería acompañar los valores de fluencia para describir y comprender mejor una

  1. Repetition suppression in ventral visual cortex is diminished as a function of increasing autistic traits

    NARCIS (Netherlands)

    Ewbank, M.P.; Rhodes, G.; von dem Hagen, E.A.H.; Powell, T.E.; Bright, N.; Stoyanova, R.Z.; Baron-Cohen, S.; Calder, A.J.

    2015-01-01

    Repeated viewing of a stimulus causes a change in perceptual sensitivity, known as a visual aftereffect. Similarly, in neuroimaging, repetitions of the same stimulus result in a reduction in the neural response, known as repetition suppression (RS). Previous research shows that aftereffects for

  2. Low-threshold, nanosecond, high-repetition-rate vortex pulses with controllable helicity generated in Cr,Nd:YAG self-Q-switched microchip laser

    Science.gov (United States)

    He, Hong-Sen; Chen, Zhen; Li, Hong-Bin; Dong, Jun

    2018-05-01

    A high repetition rate, nanosecond, pulsed optical vortex beam has been generated in a Cr,Nd:YAG self-Q-switched microchip laser pumped by the annular-beam formed with a hollow focus lens. The lasing threshold for vortex pulses is 0.9 W. A pulse width of 6.5 ns and a repetition rate of over 330 kHz have been achieved. The average output power of 1 W and the slope efficiency of 46.6% have been obtained. The helicity of the optical vortices has been controlled by adjusting the tilted angle between Cr,Nd:YAG crystal and output coupler. The work provides a new method for developing pulsed optical vortices for potential applications on quantum communication and optical trapping.

  3. MIMICRY, DIFFERENCE AND REPETITION

    Directory of Open Access Journals (Sweden)

    Marcelo Mendes de Souza

    2008-07-01

    Full Text Available This article addresses Homi K. Bhabha’s concept of mimicry in a broader context, other than that of cultural studies and post-colonial studies, bringing together other concepts, such as that of Gilles Deleuze in Difference and repetition, among other texts, and other names, such as Silviano Santiago, Jorge Luís Borges, Franz Kafka and Giorgio Agamben. As a partial conclusion, the article intends to oppose Bhabha’s freudian-marxist view to Five propositions on Psychoanalysis (1973, Gilles Deleuze’s text about Psychoanalysis published right after his book The Anti-Oedipus.

  4. Grade Repetition in Queensland State Prep Classes

    Science.gov (United States)

    Anderson, Robyn

    2012-01-01

    The current study considers grade repetition rates in the early years of schooling in Queensland state schools with specific focus on the pre-schooling year, Prep. In particular, it provides empirical evidence of grade repetition in Queensland state schools along with groups of students who are more often repeated. At the same time, much of the…

  5. A HIGH REPETITION RATE VUV-SOFT X-RAY FEL CONCEPT

    International Nuclear Information System (INIS)

    Corlett, J.; Byrd, J.; Fawley, W.M.; Gullans, M.; Li, D.; Lidia, S.M.; Padmore, H.; Penn, G.; Pogorelov, I.; Qiang, J.; Robin, D.; Sannibale, F.; Staples, J.W.; Steier, C.; Venturini, M.; Virostek, S.; Wan, W.; Wells, R.; Wilcox, R.; Wurtele, J.; Zholents, A.

    2007-01-01

    We report on design studies for a seeded FEL light source that is responsive to the scientific needs of the future. The FEL process increases radiation flux by several orders of magnitude above existing incoherent sources, and offers the additional enhancements attainable by optical manipulations of the electron beam: control of the temporal duration and bandwidth of the coherent output, reduced gain length in the FEL, utilization of harmonics to attain shorter wavelengths, and precise synchronization of the x-ray pulse with seed laser systems. We describe an FEL facility concept based on a high repetition rate RF photocathode gun, that would allow simultaneous operation of multiple independent FEL's, each producing high average brightness, tunable over the VUV-soft x-ray range, and each with individual performance characteristics determined by the configuration of the FEL. SASE, enhanced-SASE (ESASE), seeded, harmonic generation, and other configurations making use of optical manipulations of the electron beam may be employed, providing a wide range of photon beam properties to meet varied user demands

  6. RPERT: Repetitive-Projects Evaluation and Review Technique

    Directory of Open Access Journals (Sweden)

    Remon Fayek Aziz

    2014-03-01

    Full Text Available Estimating expected completion probability of any repetitive construction project with a specified/certain duration including repetitive identical activities by using program evaluation and review technique is the most essential part in construction areas since the activities were had optimistic, most likely and pessimistic durations. This paper focuses on the calculation of expected completion probability of any repetitive construction project within a specified/certain duration (contract duration by using Line Of Balance technique (LOB in case of single or multiple number of crews integrated with Program Evaluation and Review Technique (PERT. Repetitive-Projects Evaluation and Review Technique (RPERT, which is a simplified software, will generate the expected project completion probability of a specified/certain duration (contract duration. RPERT software is designed by java programming code system to provide a number of new and unique capabilities, including: (1 Viewing the expected project completion probability according to a set of specified durations per each identical activity (optimistic time, most likely time, and pessimistic time in the analyzed project; (2 Providing seamless integration with available project time calculations. In order to provide the aforementioned capabilities of RPERT, the system is implemented and developed in four main modules: (1 A user interface module; (2 A database module; (3 A running module; and (4 A processing module. At the end, an illustrative example will be presented to demonstrate and verify the applications of proposed software (RPERT, by using probabilistic calculations for repetitive construction projects.

  7. Repetition Enhancement of Amygdala and Visual Cortex Functional Connectivity Reflects Nonconscious Memory for Negative Visual Stimuli.

    Science.gov (United States)

    Kark, Sarah M; Slotnick, Scott D; Kensinger, Elizabeth A

    2016-12-01

    Most studies using a recognition memory paradigm examine the neural processes that support the ability to consciously recognize past events. However, there can also be nonconscious influences from the prior study episode that reflect repetition suppression effects-a reduction in the magnitude of activity for repeated presentations of stimuli-that are revealed by comparing neural activity associated with forgotten items to correctly rejected novel items. The present fMRI study examined the effect of emotional valence (positive vs. negative) on repetition suppression effects. Using a standard recognition memory task, 24 participants viewed line drawings of previously studied negative, positive, and neutral photos intermixed with novel line drawings. For each item, participants made an old-new recognition judgment and a sure-unsure confidence rating. Collapsed across valence, repetition suppression effects were found in ventral occipital-temporal cortex and frontal regions. Activity levels in the majority of these regions were not modulated by valence. However, repetition enhancement of the amygdala and ventral occipital-temporal cortex functional connectivity reflected nonconscious memory for negative items. In this study, valence had little effect on activation patterns but had a larger effect on functional connectivity patterns that were markers of nonconscious memory. Beyond memory and emotion, these findings are relevant to other cognitive and social neuroscientists that utilize fMRI repetition effects to investigate perception, attention, social cognition, and other forms of learning and memory.

  8. Repetitive Stress Injuries

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Repetitive Stress Injuries KidsHealth / For Teens / Repetitive Stress Injuries What's ... t had any problems since. What Are Repetitive Stress Injuries? Repetitive stress injuries (RSIs) are injuries that ...

  9. Nanosecond radar system based on repetitive pulsed relativistic BWO

    International Nuclear Information System (INIS)

    Bunkin, B.V.; Gaponov-Grekhov, A.V.; Eltchaninov, A.S.; Zagulov, F.Ya.; Korovin, S.D.; Mesyats, G.A.; Osipov, M.L.; Otlivantchik, E.A.; Petelin, M.I.; Prokhorov, A.M.

    1993-01-01

    The paper presents the results of studies of a nanosecond radar system based on repetitive pulsed relativistic BWO. A pulsed power repetitive accelerator producing electron beams of electron energy 500-700 keV and current 5 kA in pulses of duraction 10 ns with a repetition rate of 100 pps is described. The results of experiments with a high-voltage gas-filled spark gap and a cold-cathode vacuum diode under the conditions of high repetition rates are given. Also presented are the results of studies of a relativistic BWO operating with a wavelength of 3 cm. It is shown that for a high-current beam electron energy of 500-700 keV, the BWO efficiency can reach 35%, the microwave power being 10 9 W. A superconducting solenoid creating a magnetic field of 30 kOe was used for the formation and transportation of the high-current electron beam. In conclusion, the outcome of tests of a nanosecond radar station based on a pulsed power repetitive accelerator and a relativistic BWO is reported

  10. Observation of Repetition-Rate Dependent Emission From an Un-Gated Thermionic Cathode Rf Gun

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, J. P.; Sun, Y.; Harris, J.R.; Lewellen, J.W.

    2017-06-02

    Recent work at Fermilab in collaboration with the Advanced Photon Source and members of other national labs, designed an experiment to study the relationship between the RF repetition rate and the average current per RF pulse. While existing models anticipate a direct relationship between these two parameters we observed an inverse relationship. We believe this is a result of damage to the barium coating on the cathode surface caused by a change in back-bombardment power that is unaccounted for in the existing theories. These observations shed new light on the challenges and fundamental limitations associated with scaling an ungated thermionic cathode RF gun to high average current.

  11. Repetition and brain potentials when recognizing natural scenes: task and emotion differences

    Science.gov (United States)

    Bradley, Margaret M.; Codispoti, Maurizio; Karlsson, Marie; Lang, Peter J.

    2013-01-01

    Repetition has long been known to facilitate memory performance, but its effects on event-related potentials (ERPs), measured as an index of recognition memory, are less well characterized. In Experiment 1, effects of both massed and distributed repetition on old–new ERPs were assessed during an immediate recognition test that followed incidental encoding of natural scenes that also varied in emotionality. Distributed repetition at encoding enhanced both memory performance and the amplitude of an old–new ERP difference over centro-parietal sensors. To assess whether these repetition effects reflect encoding or retrieval differences, the recognition task was replaced with passive viewing of old and new pictures in Experiment 2. In the absence of an explicit recognition task, ERPs were completely unaffected by repetition at encoding, and only emotional pictures prompted a modestly enhanced old–new difference. Taken together, the data suggest that repetition facilitates retrieval processes and that, in the absence of an explicit recognition task, differences in old–new ERPs are only apparent for affective cues. PMID:22842817

  12. Recency, repetition, and the multidimensional basis of recognition memory.

    Science.gov (United States)

    Buchsbaum, Bradley R; Lemire-Rodger, Sabrina; Bondad, Ashley; Chepesiuk, Alexander

    2015-02-25

    Recency and repetition are two factors that have large effects on human memory performance. One way of viewing the beneficial impact of these variables on recognition memory is to assume that both factors modulate a unidimensional memory trace strength. Although previous functional neuroimaging studies have indicated that recency and repetition may modulate similar brain structures, particularly in the region of the inferior parietal cortex, there is extensive behavioral evidence that human subjects can make independent and accurate recognition memory judgments about both an item's recency and its frequency. In the present study, we used fMRI to examine patterns of brain activity during recognition memory for auditory-verbal stimuli that were parametrically and orthogonally manipulated in terms of recency and number of repetitions. We found in a continuous recognition paradigm that the lateral inferior parietal cortex, a region that has previously been associated with recollective forms of memory, is highly sensitive to recency but not repetition. In a multivariate analysis of whole-brain activation patterns, we found orthogonal components that dissociated recency and repetition variables, indicating largely independent neural bases underlying these two factors. The results demonstrate that although both recency and repetition dramatically improve recognition memory performance, the neural bases for this improvement are dissociable, and thus are difficult to explain in terms of access to a unitary memory trace. Copyright © 2015 the authors 0270-6474/15/353544-11$15.00/0.

  13. Characteristics of Partial Discharge and Ozone Generation for Twisted-pair of Enameled Wires under High-repetitive Impulse Voltage Application

    Science.gov (United States)

    Kanazawa, Seiji; Enokizono, Masato; Shibakita, Toshihide; Umehara, Eiji; Toshimitsu, Jun; Ninomiya, Shinji; Taniguchi, Hideki; Abe, Yukari

    In recent years, inverter drive machines such as a hybrid vehicle and an electric vehicle are operated under high voltage pulse with high repetition rate. In this case, inverter surge is generated and affected the machine operation. Especially, the enameled wire of a motor is deteriorated due to the partial discharge (PD) and finally breakdown of the wire will occur. In order to investigate a PD on a resistant enameled wire, characteristics of PD in the twisted pair sample under bipolar repetitive impulse voltages are investigated experimentally. The relationship between the applied voltage and discharge current was measured at PD inception and extinction, and we estimated the repetitive PD inception and extinction voltages experimentally. The corresponding optical emission of the discharge was also observed by using an ICCD camera. Furthermore, ozone concentration due to the discharge was measured during the life-time test of the resistant enameled wires from a working environmental point of view.

  14. Human sensory-evoked responses differ coincident with either "fusion-memory" or "flash-memory", as shown by stimulus repetition-rate effects

    Directory of Open Access Journals (Sweden)

    Baird Bill

    2006-02-01

    Full Text Available Abstract Background: A new method has been used to obtain human sensory evoked-responses whose time-domain waveforms have been undetectable by previous methods. These newly discovered evoked-responses have durations that exceed the time between the stimuli in a continuous stream, thus causing an overlap which, up to now, has prevented their detection. We have named them "A-waves", and added a prefix to show the sensory system from which the responses were obtained (visA-waves, audA-waves, somA-waves. Results: When A-waves were studied as a function of stimulus repetition-rate, it was found that there were systematic differences in waveshape at repetition-rates above and below the psychophysical region in which the sensation of individual stimuli fuse into a continuity. The fusion phenomena is sometimes measured by a "Critical Fusion Frequency", but for this research we can only identify a frequency-region [which we call the STZ (Sensation-Transition Zone]. Thus, the A-waves above the STZ differed from those below the STZ, as did the sensations. Study of the psychophysical differences in auditory and visual stimuli, as shown in this paper, suggest that different stimulus features are detected, and remembered, at stimulation rates above and below STZ. Conclusion: The results motivate us to speculate that: 1 Stimulus repetition-rates above the STZ generate waveforms which underlie "fusion-memory" whereas rates below the STZ show neuronal processing in which "flash-memory" occurs. 2 These two memories differ in both duration and mechanism, though they may occur in the same cell groups. 3 The differences in neuronal processing may be related to "figure" and "ground" differentiation. We conclude that A-waves provide a novel measure of neural processes that can be detected on the human scalp, and speculate that they may extend clinical applications of evoked response recordings. If A-waves also occur in animals, it is likely that A-waves will provide

  15. Human sensory-evoked responses differ coincident with either "fusion-memory" or "flash-memory", as shown by stimulus repetition-rate effects

    Science.gov (United States)

    Jewett, Don L; Hart, Toryalai; Larson-Prior, Linda J; Baird, Bill; Olson, Marram; Trumpis, Michael; Makayed, Katherine; Bavafa, Payam

    2006-01-01

    Background: A new method has been used to obtain human sensory evoked-responses whose time-domain waveforms have been undetectable by previous methods. These newly discovered evoked-responses have durations that exceed the time between the stimuli in a continuous stream, thus causing an overlap which, up to now, has prevented their detection. We have named them "A-waves", and added a prefix to show the sensory system from which the responses were obtained (visA-waves, audA-waves, somA-waves). Results: When A-waves were studied as a function of stimulus repetition-rate, it was found that there were systematic differences in waveshape at repetition-rates above and below the psychophysical region in which the sensation of individual stimuli fuse into a continuity. The fusion phenomena is sometimes measured by a "Critical Fusion Frequency", but for this research we can only identify a frequency-region [which we call the STZ (Sensation-Transition Zone)]. Thus, the A-waves above the STZ differed from those below the STZ, as did the sensations. Study of the psychophysical differences in auditory and visual stimuli, as shown in this paper, suggest that different stimulus features are detected, and remembered, at stimulation rates above and below STZ. Conclusion: The results motivate us to speculate that: 1) Stimulus repetition-rates above the STZ generate waveforms which underlie "fusion-memory" whereas rates below the STZ show neuronal processing in which "flash-memory" occurs. 2) These two memories differ in both duration and mechanism, though they may occur in the same cell groups. 3) The differences in neuronal processing may be related to "figure" and "ground" differentiation. We conclude that A-waves provide a novel measure of neural processes that can be detected on the human scalp, and speculate that they may extend clinical applications of evoked response recordings. If A-waves also occur in animals, it is likely that A-waves will provide new methods for

  16. Laterality of repetitive finger movement performance and clinical features of Parkinson's disease.

    Science.gov (United States)

    Stegemöller, Elizabeth; Zaman, Andrew; MacKinnon, Colum D; Tillman, Mark D; Hass, Chris J; Okun, Michael S

    2016-10-01

    Impairments in acoustically cued repetitive finger movement often emerge at rates near to and above 2Hz in persons with Parkinson's Disease (PD) in which some patients move faster (hastening) and others move slower (bradykinetic). The clinical features impacting this differential performance of repetitive finger movement remain unknown. The purpose of this study was to compare repetitive finger movement performance between the more and less affected side, and the difference in clinical ratings among performance groups. Forty-one participants diagnosed with idiopathic PD completed an acoustically cued repetitive finger movement task while "on" medication. Eighteen participants moved faster, 10 moved slower, and 13 were able to maintain the appropriate rate at rates above 2Hz. Clinical measures of laterality, disease severity, and the UPDRS were obtained. There were no significant differences between the more and less affected sides regardless of performance group. Comparison of disease severity, tremor, and rigidity among performance groups revealed no significant differences. Comparison of posture and postural instability scores revealed that the participants that demonstrated hastening had worse posture and postural instability scores. Consideration of movement rate during the clinical evaluation of repetitive finger movement may provide additional insight into varying disease features in persons with PD. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    International Nuclear Information System (INIS)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-01-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO

  18. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

    2014-05-15

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  19. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  20. BOLD repetition decreases in object-responsive ventral visual areas depend on spatial attention.

    Science.gov (United States)

    Eger, E; Henson, R N A; Driver, J; Dolan, R J

    2004-08-01

    Functional imaging studies of priming-related repetition phenomena have become widely used to study neural object representation. Although blood oxygenation level-dependent (BOLD) repetition decreases can sometimes be observed without awareness of repetition, any role for spatial attention in BOLD repetition effects remains largely unknown. We used fMRI in 13 healthy subjects to test whether BOLD repetition decreases for repeated objects in ventral visual cortices depend on allocation of spatial attention to the prime. Subjects performed a size-judgment task on a probe object that had been attended or ignored in a preceding prime display of 2 lateralized objects. Reaction times showed faster responses when the probe was the same object as the attended prime, independent of the view tested (identical vs. mirror image). No behavioral effect was evident from unattended primes. BOLD repetition decreases for attended primes were found in lateral occipital and fusiform regions bilaterally, which generalized across identical and mirror-image repeats. No repetition decreases were observed for ignored primes. Our results suggest a critical role for attention in achieving visual representations of objects that lead to both BOLD signal decreases and behavioral priming on repeated presentation.

  1. Research of narrow pulse width, high repetition rate, high output power fiber lasers for deep space exploration

    Science.gov (United States)

    Tang, Yan-feng; Li, Hong-zuo; Wang, Yan; Hao, Zi-qiang; Xiao, Dong-Ya

    2013-08-01

    As human beings expand the research in unknown areas constantly, the deep space exploration has become a hot research topic all over the world. According to the long distance and large amount of information transmission characteristics of deep space exploration, the space laser communication is the preferred mode because it has the advantages of concentrated energy, good security, and large information capacity and interference immunity. In a variety of laser source, fibre-optical pulse laser has become an important communication source in deep space laser communication system because of its small size, light weight and large power. For fiber lasers, to solve the contradiction between the high repetition rate and the peak value power is an important scientific problem. General Q technology is difficult to obtain a shorter pulse widths, This paper presents a DFB semiconductor laser integrated with Electro-absorption modulator to realize the narrow pulse width, high repetition rate of the seed source, and then using a two-cascaded high gain fiber amplifier as amplification mean, to realize the fibre-optical pulse laser with pulse width 3ns, pulse frequency 200kHz and peak power 1kW. According to the space laser atmospheric transmission window, the wavelength selects for 1.06um. It is adopted that full fibre technology to make seed source and amplification, pumping source and amplification of free-space coupled into fiber-coupled way. It can overcome that fibre lasers are vulnerable to changes in external conditions such as vibration, temperature drift and other factors affect, improving long-term stability. The fiber lasers can be modulated by PPM mode, to realize high rate modulation, because of its peak power, high transmission rate, narrow pulse width, high frequency stability, all technical indexes meet the requirements of the exploration of deep space communication technology.

  2. A feasible repetitive transcranial magnetic stimulation clinical protocol in migraine prevention.

    Science.gov (United States)

    Zardouz, Shawn; Shi, Lei; Leung, Albert

    2016-01-01

    This case series was conducted to determine the clinical feasibility of a repetitive transcranial magnetic stimulation protocol for the prevention of migraine (with and without aura). Five patients with migraines underwent five repetitive transcranial magnetic stimulation sessions separated in 1- to 2-week intervals for a period of 2 months at a single tertiary medical center. Repetitive transcranial magnetic stimulation was applied to the left motor cortex with 2000 pulses (20 trains with 1s inter-train interval) delivered per session, at a frequency of 10 Hz and 80% resting motor threshold. Pre- and post-treatment numerical rating pain scales were collected, and percent reductions in intensity, frequency, and duration were generated. An average decrease in 37.8%, 32.1%, and 31.2% were noted in the intensity, frequency, and duration of migraines post-repetitive transcranial magnetic stimulation, respectively. A mean decrease in 1.9±1.0 (numerical rating pain scale ± standard deviation; range: 0.4-2.8) in headache intensity scores was noted after the repetitive transcranial magnetic stimulation sessions. The tested repetitive transcranial magnetic stimulation protocol is a well-tolerated, safe, and effective method for migraine prevention.

  3. Repetition code of 15 qubits

    Science.gov (United States)

    Wootton, James R.; Loss, Daniel

    2018-05-01

    The repetition code is an important primitive for the techniques of quantum error correction. Here we implement repetition codes of at most 15 qubits on the 16 qubit ibmqx3 device. Each experiment is run for a single round of syndrome measurements, achieved using the standard quantum technique of using ancilla qubits and controlled operations. The size of the final syndrome is small enough to allow for lookup table decoding using experimentally obtained data. The results show strong evidence that the logical error rate decays exponentially with code distance, as is expected and required for the development of fault-tolerant quantum computers. The results also give insight into the nature of noise in the device.

  4. Design and implementation of fast charging circuit for repetitive compact torus injector

    International Nuclear Information System (INIS)

    Onchi, T.; McColl, D.; Dreval, M.; Wolfe, S.; Xiao, C.; Hirose, A.

    2014-01-01

    A novel circuit for compact torus (CT) injector operated at high repetition rates has been developed. The core technology adopted in the present work is to charge a large storage capacitor bank and quickly charge the CT capacitor bank through a stack of insulated-gate bipolar transistors (IGBTs). A system consisting of IGBTs and slow banks for the repetitive operation has been developed and installed for each discharge circuit of the University of Saskatchewan Compact Torus Injector (USCTI). A repetition rate up to 1.7 Hz and a burst of 8 CTs have been achieved

  5. Repetitive transcranial magnetic stimulation for hallucination in schizophrenia spectrum disorders: A meta-analysis.

    Science.gov (United States)

    Zhang, Yingli; Liang, Wei; Yang, Shichang; Dai, Ping; Shen, Lijuan; Wang, Changhong

    2013-10-05

    This study assessed the efficacy and tolerability of repetitive transcranial magnetic stimulation for treatment of auditory hallucination of patients with schizophrenia spectrum disorders. Online literature retrieval was conducted using PubMed, ISI Web of Science, EMBASE, Medline and Cochrane Central Register of Controlled Trials databases from January 1985 to May 2012. Key words were "transcranial magnetic stimulation", "TMS", "repetitive transcranial magnetic stimulation", and "hallucination". Selected studies were randomized controlled trials assessing therapeutic efficacy of repetitive transcranial magnetic stimulation for hallucination in patients with schizophrenia spectrum disorders. Experimental intervention was low-frequency repetitive transcranial magnetic stimulation in left temporoparietal cortex for treatment of auditory hallucination in schizophrenia spectrum disorders. Control groups received sham stimulation. The primary outcome was total scores of Auditory Hallucinations Rating Scale, Auditory Hallucination Subscale of Psychotic Symptom Rating Scale, Positive and Negative Symptom Scale-Auditory Hallucination item, and Hallucination Change Scale. Secondary outcomes included response rate, global mental state, adverse effects and cognitive function. Seventeen studies addressing repetitive transcranial magnetic stimulation for treatment of schizophrenia spectrum disorders were screened, with controls receiving sham stimulation. All data were completely effective, involving 398 patients. Overall mean weighted effect size for repetitive transcranial magnetic stimulation versus sham stimulation was statistically significant (MD = -0.42, 95%CI: -0.64 to -0.20, P = 0.000 2). Patients receiving repetitive transcranial magnetic stimulation responded more frequently than sham stimulation (OR = 2.94, 95%CI: 1.39 to 6.24, P = 0.005). No significant differences were found between active repetitive transcranial magnetic stimulation and sham stimulation for

  6. Repetition suppression and multi-voxel pattern similarity differentially track implicit and explicit visual memory.

    Science.gov (United States)

    Ward, Emily J; Chun, Marvin M; Kuhl, Brice A

    2013-09-11

    Repeated exposure to a visual stimulus is associated with corresponding reductions in neural activity, particularly within visual cortical areas. It has been argued that this phenomenon of repetition suppression is related to increases in processing fluency or implicit memory. However, repetition of a visual stimulus can also be considered in terms of the similarity of the pattern of neural activity elicited at each exposure--a measure that has recently been linked to explicit memory. Despite the popularity of each of these measures, direct comparisons between the two have been limited, and the extent to which they differentially (or similarly) relate to behavioral measures of memory has not been clearly established. In the present study, we compared repetition suppression and pattern similarity as predictors of both implicit and explicit memory. Using functional magnetic resonance imaging, we scanned 20 participants while they viewed and categorized repeated presentations of scenes. Repetition priming (facilitated categorization across repetitions) was used as a measure of implicit memory, and subsequent scene recognition was used as a measure of explicit memory. We found that repetition priming was predicted by repetition suppression in prefrontal, parietal, and occipitotemporal regions; however, repetition priming was not predicted by pattern similarity. In contrast, subsequent explicit memory was predicted by pattern similarity (across repetitions) in some of the same occipitotemporal regions that exhibited a relationship between priming and repetition suppression; however, explicit memory was not related to repetition suppression. This striking double dissociation indicates that repetition suppression and pattern similarity differentially track implicit and explicit learning.

  7. High-repetition-rate laser-proton acceleration from a condensed hydrogen jet

    Energy Technology Data Exchange (ETDEWEB)

    Obst, Lieselotte; Zeil, Karl; Metzkes, Josefine; Schlenvoigt, Hans-Peter; Rehwald, Martin; Sommer, Philipp; Brack, Florian; Schramm, Ulrich [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Dresden (Germany); Goede, Sebastian; Gauthier, Maxence; Roedel, Christian; MacDonald, Michael; Schumaker, William; Glenzer, Siegfried [SLAC National Accelerator Laboratory, Stanford (United States)

    2016-07-01

    Applications of laser-accelerated protons demand a stable source of energetic particles at high repetition rates. We present the results of our experimental campaign in cooperation with MEC/SLAC at the 10Hz Ti:Sa laser Draco of Helmholtz-Zentrum Dresden-Rossendorf (HZDR), employing a pure condensed hydrogen jet as a renewable target. Draco delivers pulses of 30 fs and 5 J at 800 nm, focused to a 3 μm spot by an F/2.5 off-axis parabolic mirror. The jet's nominal electron density is approximately 30 times the critical density and its thickness is 2 μm, 5 μm or 10 μm, depending on the applied aperture on the source. Ion diagnostics reveal mono-species proton acceleration in a solid angle of at least +/-45 with respect to the incoming laser beam, with maximum energies of around 5 MeV. The expanding jet could be monitored on-shot with a temporally synchronized probe beam perpendicular to the pump laser axis. Recorded probe images resemble those of z-pinch experiments with metal wires and indicate an m=0 instability in the plasma.

  8. New results on spin determination of nanosatellite BLITS from High Repetition Rate SLR data

    Science.gov (United States)

    Kucharski, D.; Kirchner, G.; Lim, H.-C.; Koidl, F.

    2013-03-01

    The nanosatellite BLITS (Ball Lens In The Space) demonstrates a successful design of the new spherical lens type satellite for Satellite Laser Ranging (SLR). The spin parameters of the satellite were calculated from more than 1000 days of SLR data collected from 6 High Repetition Rate (HRR) systems: Beijing, Changchun, Graz, Herstmonceux, Potsdam, Shanghai.Analysis of the 892 passes (September 26, 2009-June 18, 2012) shows precession of the spin axis around orientation of the along track vector calculated at the launch epoch of the satellite RA = 9h16m39s, Dec = 43.1°. The spin period of BLITS remains stable with the mean value Tmean = 5.613 s, RMS = 11 ms. The incident angle between the spin axis and the symmetry axis of the body changes within 60° range.

  9. Heat accumulation during high repetition rate ultrafast laser interaction: Waveguide writing in borosilicate glass

    International Nuclear Information System (INIS)

    Zhang, Haibin; Eaton, Shane M; Li, Jianzhao; Herman, Peter R

    2007-01-01

    During high repetition rate (>200 kHz) ultrafast laser waveguide writing, visible heat modified zones surrounding the formed waveguide occur as a result of heat accumulation. The radii of the heat-modified zones increase with the laser net fluence, and were found to correlate with the formation of low-loss and cylindrically symmetric optical waveguides. A numerical thermal model based on the finite difference method is applied here to account for cumulative heating and diffusion effects. The model successfully shows that heat propagation and accumulation accurately predict the radius of the 'heat modified' zones observed in borosilicate glass waveguides formed across a wide range of laser exposure conditions. Such modelling promises better control of thermal effects for optimizing the fabrication and performance of three-dimensional optical devices in transparent materials

  10. Progress in developing repetitive pulse systems utilizing inductive energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Honig, E.M.

    1983-01-01

    High-power, fast-recovery vacuum switches were used in a new repetitive counterpulse and transfer circuit to deliver a 5-kHz pulse train with a peak power of 75 MW (at 8.6 kA) to a 1-..cap omega.. load, resulting in the first demonstration of fully controlled, high-power, high-repetition-rate operation of an inductive energy-storage and transfer system with nondestructive switches. New circuits, analytical and experimental results, and feasibility of 100-kV repetitive pulse generation are discussed. A new switching concept for railgun loads is presented.

  11. Narrow Q-switching pulse width and low mode-locking repetition rate Q-switched mode locking with a new coupled laser cavity

    International Nuclear Information System (INIS)

    Peng, J Y; Zheng, Y; Shen, J P; Shi, Y X

    2013-01-01

    An original diode-pumped Q-switched and mode-locked solid state Nd:GdVO 4 laser is demonstrated. The laser operates with double saturable absorbers and a new coupled laser cavity. The Q-switching envelope width is compressed to be about 15 ns and the mode-locking repetition rate is as low as 90 MHz. (paper)

  12. Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

    Science.gov (United States)

    He, Z.-H.; Thomas, A. G. R.; Beaurepaire, B.; Nees, J. A.; Hou, B.; Malka, V.; Krushelnick, K.; Faure, J.

    2013-02-01

    We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

  13. Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    He, Z.-H.; Thomas, A. G. R.; Nees, J. A.; Hou, B.; Krushelnick, K. [Center for Ultrafast Optical Science, University of Michigan, Ann Arbor, Michigan 48106-2099 (United States); Beaurepaire, B.; Malka, V.; Faure, J. [Laboratoire d' Optique Appliquee, ENSTA-CNRS-Ecole Polytechnique, UMR 7639, 91761 Palaiseau (France)

    2013-02-11

    We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

  14. Repetition and Translation Shifts

    Directory of Open Access Journals (Sweden)

    Simon Zupan

    2006-06-01

    Full Text Available Repetition manifests itself in different ways and at different levels of the text. The first basic type of repetition involves complete recurrences; in which a particular textual feature repeats in its entirety. The second type involves partial recurrences; in which the second repetition of the same textual feature includes certain modifications to the first occurrence. In the article; repetitive patterns in Edgar Allan Poe’s short story “The Fall of the House of Usher” and its Slovene translation; “Konec Usherjeve hiše”; are compared. The author examines different kinds of repetitive patterns. Repetitions are compared at both the micro- and macrostructural levels. As detailed analyses have shown; considerable microstructural translation shifts occur in certain types of repetitive patterns. Since these are not only occasional; sporadic phenomena; but are of a relatively high frequency; they reduce the translated text’s potential for achieving some of the gothic effects. The macrostructural textual property particularly affected by these shifts is the narrator’s experience as described by the narrative; which suffers a reduction in intensity.

  15. Repetitive transcranial magnetic stimulation for hallucination in schizophrenia spectrum disorders A meta-analysis***

    Institute of Scientific and Technical Information of China (English)

    Yingli Zhang; Wei Liang; Shichang Yang; Ping Dai; Lijuan Shen; Changhong Wang

    2013-01-01

    OBJECTIVE: This study assessed the efficacy and tolerability of repetitive transcranial magnetic stimulation for treatment of auditory hal ucination of patients with schizophrenia spectrum disorders. DATA SOURCES: Online literature retrieval was conducted using PubMed, ISI Web of Science, EMBASE, Medline and Cochrane Central Register of Control ed Trials databases from January 1985 to May 2012. Key words were “transcranial magnetic stimulation”, “TMS”, “repetitive transcranial magnetic stimulation”, and “hal ucination”. STUDY SELECTION: Selected studies were randomized control ed trials assessing therapeutic ef-ficacy of repetitive transcranial magnetic stimulation for hal ucination in patients with schizophrenia spectrum disorders. Experimental intervention was low-frequency repetitive transcranial magnetic stimulation in left temporoparietal cortex for treatment of auditory hal ucination in schizophrenia spectrum disorders. Control groups received sham stimulation. MAIN OUTCOME MEASURES: The primary outcome was total scores of Auditory Hal ucinations Rating Scale, Auditory Hal ucination Subscale of Psychotic Symptom Rating Scale, Positive and Negative Symptom Scale-Auditory Hal ucination item, and Hal ucination Change Scale. Secondary outcomes included response rate, global mental state, adverse effects and cognitive function. RESULTS: Seventeen studies addressing repetitive transcranial magnetic stimulation for treatment of schizophrenia spectrum disorders were screened, with controls receiving sham stimulation. Al data were completely effective, involving 398 patients. Overal mean weighted effect size for repeti-tive transcranial magnetic stimulation versus sham stimulation was statistical y significant (MD =-0.42, 95%CI: -0.64 to -0.20, P = 0.000 2). Patients receiving repetitive transcranial magnetic stimulation responded more frequently than sham stimulation (OR = 2.94, 95%CI: 1.39 to 6.24, P =0.005). No significant differences were found

  16. A clinical repetitive transcranial magnetic stimulation service in Australia: 6 years on.

    Science.gov (United States)

    Galletly, Cherrie A; Clarke, Patrick; Carnell, Benjamin L; Gill, Shane

    2015-11-01

    There is considerable research evidence for the effectiveness of repetitive transcranial magnetic stimulation in the treatment of depression. However, there is little information about its acceptability and outcomes in clinical settings. This naturalistic study reports on a clinical repetitive transcranial magnetic stimulation service that has been running in Adelaide, South Australia (SA), for 6 years. During this time, 214 complete acute courses were provided to patients with treatment-resistant Major Depressive Disorder. Patients received either sequential bilateral or right unilateral repetitive transcranial magnetic stimulation treatment involving either 18 or 20 sessions given over 6 or 4 weeks respectively. Data included patient demographic details, duration of depression, and medication at the beginning of their repetitive transcranial magnetic stimulation course. The Hamilton Depression Rating Scale was used to assess response to repetitive transcranial magnetic stimulation. Of those undergoing a first-time acute treatment course of repetitive transcranial magnetic stimulation (N = 167), 28% achieved remission, while a further 12% met the criteria for a response to treatment. Most patients (N = 123, 77%) had previously been treated with five or more antidepressant medications, and 77 (47%) had previously received electroconvulsive therapy. Referral rates remained high over the 6 years, indicating acceptance of the treatment by referring psychiatrists. There were no significant adverse events, and the treatment was generally well tolerated. In all, 41 patients (25%) had a second course of repetitive transcranial magnetic stimulation and 6 (4%) patients had a third course; 21 patients subsequently received maintenance repetitive transcranial magnetic stimulation. This naturalistic study showed that repetitive transcranial magnetic stimulation was well accepted by both psychiatrists and patients, and has good efficacy and safety. Furthermore

  17. Active power filter for harmonic compensation using a digital dual-mode-structure repetitive control approach

    DEFF Research Database (Denmark)

    Zou, Zhixiang; Wang, Zheng; Cheng, Ming

    2012-01-01

    This paper presents an digital dual-mode-structure repetitive control approach for the single-phase shunt active power filter (APF), which aims to enhance the tracking ability and eliminate arbitrary order harmonic. The proposed repetitive control scheme blends the characteristics of both odd......-harmonic repetitive control and even-harmonic repetitive control. Moreover, the convergence rate is faster than conventional repetitive controller. Additionally, the parameters have been designed and optimized for the dual-mode structure repetitive control to improve the performance of APF system. Experimental...

  18. The Adversarial Principle in Prima Facie Judgments of the Legal Thesis Firmed in the Trial of Repetitive Cases

    Directory of Open Access Journals (Sweden)

    Juliana Provedel Cardoso

    2016-10-01

    Full Text Available The present articles objective is to analyse the highly effective adversarial principle from the Constitutional Democratic State of Law and the cooperative process structure. In this sense, an analysis of the repetitive cases model is made with special relevance to the Civil Procedure Codice 2015, put in evidence the preliminary injunction, the repetitive appeals and the resolution incident repetitive demands. With the establishment of the premises, an analysis of the adversarial principle is made on prima facie judgments of the legal thesis firmed in the trial of repetitive cases, in view of the motivation of the court decision (speech of the case and law (speech of the precedents.

  19. Generation of nanosecond laser pulses at a 2.2-MHz repetition rate by a cw diode-pumped passively Q-switched Nd3+:YVO4 laser

    International Nuclear Information System (INIS)

    Nghia, Nguyen T; Hao, Nguyen V; Orlovich, Valentin A; Hung, Nguyen D

    2011-01-01

    We report a new configuration of a high-repetition rate nanosecond laser based on a semiconductor saturable absorber mirror (SESAM). The SESAM is conventional technical solution for passive mode-locking at 1064 nm and simultaneously used as a highly reflecting mirror and a saturable absorber in a high-Q and short cavity of a cw diode-end-pumped a-cut Nd 3+ :YVO 4 laser. Two laser beams are coupled out from the cavity using an intracavity low-reflection thin splitter. The laser characteristics are investigated as functions of pump and resonator parameters. Using a 1.8-W cw pump laser diode at 808 nm, the passively Q-switched SESAMbased laser generates 22-ns pulses with an average power of 275 mW at a pulse repetition rate of 2250 kHz.

  20. Contribution of fronto-striatal regions to emotional valence and repetition under cognitive conflict.

    Science.gov (United States)

    Chun, Ji-Won; Park, Hae-Jeong; Kim, Dai Jin; Kim, Eosu; Kim, Jae-Jin

    2017-07-01

    Conflict processing mediated by fronto-striatal regions may be influenced by emotional properties of stimuli. This study aimed to examine the effects of emotion repetition on cognitive control in a conflict-provoking situation. Twenty-one healthy subjects were scanned using functional magnetic resonance imaging while performing a sequential cognitive conflict task composed of emotional stimuli. The regional effects were analyzed according to the repetition or non-repetition of cognitive congruency and emotional valence between the preceding and current trials. Post-incongruence interference in error rate and reaction time was significantly smaller than post-congruence interference, particularly under repeated positive and non-repeated positive, respectively, and post-incongruence interference, compared to post-congruence interference, increased activity in the ACC, DLPFC, and striatum. ACC and DLPFC activities were significantly correlated with error rate or reaction time in some conditions, and fronto-striatal connections were related to the conflict processing heightened by negative emotion. These findings suggest that the repetition of emotional stimuli adaptively regulates cognitive control and the fronto-striatal circuit may engage in the conflict adaptation process induced by emotion repetition. Both repetition enhancement and repetition suppression of prefrontal activity may underlie the relationship between emotion and conflict adaptation. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A compact, repetitive accelerator for military and industrial applications

    International Nuclear Information System (INIS)

    Zutavern, F.J.; O'Malley, M.W.; Ruebush, M.H.; Rinehart, L.F.; Loubriel, G.M.; Babcock, S.R.; Denison, G.J.

    1998-04-01

    A compact, short pulse, repetitive accelerator has many useful military and commercial applications in biological counter proliferation, materials processing, radiography, and sterilization (medical instruments, waste, and food). The goal of this project was to develop and demonstrate a small, 700 kV accelerator, which can produce 7 kA particle beams with pulse lengths of 10--30 ns at rates up to 50 Hz. At reduced power levels, longer pulses or higher repetition rates (up to 10 kHz) could be achieved. Two switching technologies were tested: (1) spark gaps, which have been used to build low repetition rate accelerators for many years; and (2) high gain photoconductive semiconductor switches (PCSS), a new solid state switching technology. This plan was economical, because it used existing hardware for the accelerator, and the PCSS material and fabrication for one module was relatively inexpensive. It was research oriented, because it provided a test bed to examine the utility of other emerging switching technologies, such as magnetic switches. At full power, the accelerator will produce 700 kV and 7 kA with either the spark gap or PCSS pulser

  2. Universal data compression and repetition times

    NARCIS (Netherlands)

    Willems, Frans M J

    1989-01-01

    A new universal data compression algorithm is described. This algorithm encodes L source symbols at a time. For the class of binary stationary sources, its rate does not exceed [formula omitted] [formula omitted] bits per source symbol. In our analysis, a property of repetition times turns out to be

  3. Repetition priming of face recognition in a serial choice reaction-time task.

    Science.gov (United States)

    Roberts, T; Bruce, V

    1989-05-01

    Marshall & Walker (1987) found that pictorial stimuli yield visual priming that is disrupted by an unpredictable visual event in the response-stimulus interval. They argue that visual stimuli are represented in memory in the form of distinct visual and object codes. Bruce & Young (1986) propose similar pictorial, structural and semantic codes which mediate the recognition of faces, yet repetition priming results obtained with faces as stimuli (Bruce & Valentine, 1985), and with objects (Warren & Morton, 1982) are quite different from those of Marshall & Walker (1987), in the sense that recognition is facilitated by pictures presented 20 minutes earlier. The experiment reported here used different views of familiar and unfamiliar faces as stimuli in a serial choice reaction-time task and found that, with identical pictures, repetition priming survives and intervening item requiring a response, with both familiar and unfamiliar faces. Furthermore, with familiar faces such priming was present even when the view of the prime was different from the target. The theoretical implications of these results are discussed.

  4. Structurally Complex Organization of Repetitive DNAs in the Genome of Cobia (Rachycentron canadum).

    Science.gov (United States)

    Costa, Gideão W W F; Cioffi, Marcelo de B; Bertollo, Luiz A C; Molina, Wagner F

    2015-06-01

    Repetitive DNAs comprise the largest fraction of the eukaryotic genome. They include microsatellites or simple sequence repeats (SSRs), which play an important role in the chromosome differentiation among fishes. Rachycentron canadum is the only representative of the family Rachycentridae. This species has been focused on several multidisciplinary studies in view of its important potential for marine fish farming. In the present study, distinct classes of repetitive DNAs, with emphasis on SSRs, were mapped in the chromosomes of this species to improve the knowledge of its genome organization. Microsatellites exhibited a diversified distribution, both dispersed in euchromatin and clustered in the heterochromatin. The multilocus location of SSRs strengthened the heterochromatin heterogeneity in this species, as suggested by some previous studies. The colocalization of SSRs with retrotransposons and transposons pointed to a close evolutionary relationship between these repetitive sequences. A number of heterochromatic regions highlighted a greater complex organization than previously supposed, harboring a diversity of repetitive elements. In this sense, there was also evidence of colocalization of active genetic regions and different classes of repetitive DNAs in a common heterochromatic region, which offers a potential opportunity for further researches regarding the interaction of these distinct fractions in fish genomes.

  5. 200 ps FWHM and 100 MHz repetition rate ultrafast gated camera for optical medical functional imaging

    Science.gov (United States)

    Uhring, Wilfried; Poulet, Patrick; Hanselmann, Walter; Glazenborg, René; Zint, Virginie; Nouizi, Farouk; Dubois, Benoit; Hirschi, Werner

    2012-04-01

    The paper describes the realization of a complete optical imaging device to clinical applications like brain functional imaging by time-resolved, spectroscopic diffuse optical tomography. The entire instrument is assembled in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The resulting light pulses, at four wavelengths, are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera; there are resolved according to their time of flight inside the head. The very core of the intensified camera system is the image intensifier tube and its associated electrical pulse generator. The ultrafast generator produces 50 V pulses, at a repetition rate of 100 MHz and a width corresponding to the 200 ps requested gate. The photocathode and the Micro-Channel-Plate of the intensifier have been specially designed to enhance the electromagnetic wave propagation and reduce the power loss and heat that are prejudicial to the quality of the image. The whole instrumentation system is controlled by an FPGA based module. The timing of the light pulses and the photocathode gating is precisely adjustable with a step of 9 ps. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications.

  6. Roles of repetitive sequences

    Energy Technology Data Exchange (ETDEWEB)

    Bell, G.I.

    1991-12-31

    The DNA of higher eukaryotes contains many repetitive sequences. The study of repetitive sequences is important, not only because many have important biological function, but also because they provide information on genome organization, evolution and dynamics. In this paper, I will first discuss some generic effects that repetitive sequences will have upon genome dynamics and evolution. In particular, it will be shown that repetitive sequences foster recombination among, and turnover of, the elements of a genome. I will then consider some examples of repetitive sequences, notably minisatellite sequences and telomere sequences as examples of tandem repeats, without and with respectively known function, and Alu sequences as an example of interspersed repeats. Some other examples will also be considered in less detail.

  7. Interaction of Repetitively Pulsed High Energy Laser Radiation With Matter

    Science.gov (United States)

    Hugenschmidt, Manfred

    1986-10-01

    The paper is concerned with laser target interaction processes involving new methods of improving the overall energy balance. As expected theoretically, this can be achieved with high repetition rate pulsed lasers even for initially highly reflecting materials, such as metals. Experiments were performed by using a pulsed CO2 laser at mean powers up to 2 kW and repetition rates up to 100 Hz. The rates of temperature rise of aluminium for example were thereby increased by lore than a factor of 3 as compared to cw-radiation of comparable power density. Similar improvements were found for the overall absorptivities that were increased by this method by more than an order of magnitude.

  8. Evolution of repetitive explosive instabilities in space and time

    International Nuclear Information System (INIS)

    Wilhelmsson, H.

    1984-01-01

    A nonlinear rate equation describing nonlinear, explosive type interaction of waves in plasmas is studied, assuming that amplitude saturation occurs due to nonlinear frequency shifts. Emphasis is put on the space dependence of the solution caused by the assumption of a given initial amplitude distribution in space. An analysis is given of the problem of repetitive peaks governed by the nonlinear rate equation for the time development of the amplitudes of plasma waves and by a Lorentzian shape distribution of the initial amplitudes. For the one-dimensional case, the peaks developed by explosive instability move in the direction of lower initial amplitude values, and the speed and the repetition rate of the peaks are determined. The possible forms of equilibria for the nonlinear rate equation in the explosive case are also studied, including, in addition to the quadratic nonlinearity, diffusion and linear damping effects. A solution to the nonlinear rate equation including diffusion is also given for the case where the quadratic nonlinearity represents recombination. (Auth.)

  9. Influence of the laser pulse repetition rate and scanning speed on the morphology of Ag nanostructures fabricated by pulsed laser ablation of solid target in water

    Science.gov (United States)

    Nikolov, A. S.; Balchev, I. I.; Nedyalkov, N. N.; Kostadinov, I. K.; Karashanova, D. B.; Atanasova, G. B.

    2017-11-01

    Nanostructures of noble metal were produced by pulsed laser ablation in liquid. A solid Ag target was immersed in double distilled water and a CuBr laser in a master oscillator—power amplifier configuration oscillating at 511 nm and emitting pulses with duration of 30 ns at a repetition rate of up to 20 kHz was employed to produce different colloids. The impact was studied of the laser pulse repetition rate and the beam scanning speed on the morphology of the nanostructures formed. Further, the optical extinction spectra of the colloids in the UV/VIS range were measured and used to make an indirect assessment of the changes in the shape and size distribution of the nanostructures. The transmission values in the near UV range were used to estimate the efficiency of the ablation process under the different experimental conditions implemented. A visualization of the nanostructures was made possible by transmission electron microscopy (TEM). The structure and phase composition of the nanoparticles were studied by high-resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED), while the alteration of the target surface caused by the impact of the high-repetition-rate laser illumination was investigated by X-ray photoelectron spectroscopy (XPS). The optimal conditions were determined yielding the highest efficiency in terms of amount of ablated material.

  10. Generation of tunable, high repetition rate frequency combs with equalized spectra using carrier injection based silicon modulators

    Science.gov (United States)

    Nagarjun, K. P.; Selvaraja, Shankar Kumar; Supradeepa, V. R.

    2016-03-01

    High repetition-rate frequency combs with tunable repetition rate and carrier frequency are extensively used in areas like Optical communications, Microwave Photonics and Metrology. A common technique for their generation is strong phase modulation of a CW-laser. This is commonly implemented using Lithium-Niobate based modulators. With phase modulation alone, the combs have poor spectral flatness and significant number of missing lines. To overcome this, a complex cascade of multiple intensity and phase modulators are used. A comb generator on Silicon based on these principles is desirable to enable on-chip integration with other functionalities while reducing power consumption and footprint. In this work, we analyse frequency comb generation in carrier injection based Silicon modulators. We observe an interesting effect in these comb generators. Enhanced absorption accompanying carrier injection, an undesirable effect in data modulators, shapes the amplitude here to enable high quality combs from a single modulator. Thus, along with reduced power consumption to generate a specific number of lines, the complexity has also been significantly reduced. We use a drift-diffusion solver and mode solver (Silvaco TCAD) along with Soref-Bennett relations to calculate the variations in refractive indices and absorption of an optimized Silicon PIN - waveguide modulator driven by an unbiased high frequency (10 Ghz) voltage signal. Our simulations demonstrate that with a device length of 1 cm, a driving voltage of 2V and minor shaping with a passive ring-resonator filter, we obtain 37 lines with a flatness better than 5-dB across the band and power consumption an order of magnitude smaller than Lithium-Niobate modulators.

  11. A Nonword Repetition Task for Speakers with Misarticulations: The Syllable Repetition Task (SRT)

    Science.gov (United States)

    Shriberg, Lawrence D.; Lohmeier, Heather L.; Campbell, Thomas F.; Dollaghan, Christine A.; Green, Jordan R.; Moore, Christopher A.

    2009-01-01

    Purpose: Conceptual and methodological confounds occur when non(sense) word repetition tasks are administered to speakers who do not have the target speech sounds in their phonetic inventories or who habitually misarticulate targeted speech sounds. In this article, the authors (a) describe a nonword repetition task, the Syllable Repetition Task…

  12. A high repetition rate transverse beam profile diagnostic for laser-plasma proton sources

    Science.gov (United States)

    Dover, Nicholas; Nishiuchi, Mamiko; Sakaki, Hironao; Kando, Masaki; Nishitani, Keita

    2016-10-01

    The recently upgraded J-KAREN-P laser can provide PW peak power and intensities approaching 1022 Wcm-2 at 0.1 Hz. Scaling of sheath acceleration to such high intensities predicts generation of protons to near 100 MeV, but changes in electron heating mechanisms may affect the emitted proton beam properties, such as divergence and pointing. High repetition rate simultaneous measurement of the transverse proton distribution and energy spectrum are therefore key to understanding and optimising the source. Recently plastic scintillators have been used to measure online proton beam transverse profiles, removing the need for time consuming post-processing. We are therefore developing a scintillator based transverse proton beam profile diagnostic for use in ion acceleration experiments using the J-KAREN-P laser. Differential filtering provides a coarse energy spectrum measurement, and time-gating allows differentiation of protons from other radiation. We will discuss the design and implementation of the diagnostic, as well as proof-of-principle results from initial experiments on the J-KAREN-P system demonstrating the measurement of sheath accelerated proton beams up to 20 MeV.

  13. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study.

    Science.gov (United States)

    Rafferty, Elizabeth A; Park, Jeong Mi; Philpotts, Liane E; Poplack, Steven P; Sumkin, Jules H; Halpern, Elkan F; Niklason, Loren T

    2014-02-01

    The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis. Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis. Screening recall rates were compared using pooled logistical regression analysis. A p value of tomosynthesis, and DM plus two-view tomosynthesis was 0.828, 0.864, and 0.895, respectively. Both one-view and two-view tomosynthesis plus DM were significantly better than DM alone (Δ AUCs 0.036 [p = 0.009] and 0.068 [p tomosynthesis, and DM plus two-view tomosynthesis were 44.2%, 27.2%, and 24.0%, respectively. Combined with DM, one-view and two-view tomosynthesis both showed significantly lower noncancer recall rates than digital mammography alone (p tomosynthesis showed a significantly lower recall rate than digital mammography with one-view tomosynthesis (p tomosynthesis compared with digital mammography alone. Compared with digital mammography, diagnostic sensitivity for invasive cancers increased with the addition of both one-view (Δ12.0%, p tomosynthesis. The addition of one-view tomosynthesis to conventional digital mammography improved diagnostic accuracy and reduced the recall rate; however, the addition of two-view tomosynthesis provided twice the performance gain in diagnostic accuracy while further reducing the recall rate.

  14. Measurement and diagnosis system for 1.2 MV repetitive pulsed power source

    International Nuclear Information System (INIS)

    Li Yawei; Deng Jianjun; Xie Min; Feng Zongming; Liu Yuntao; Ma Chenggang

    2010-01-01

    In order to analyze the discharge performance and improve the design of the power system, a set of measurement and diagnosis system for the 1.2 MV repetitive pulsed power source, which supplies the drive power for a high power microwave source, has been designed by studying the high-voltage, high-current testing technology, data acquisition, signal processing, fault diagnosis, virtual instruments and electromagnetic compatibility technology, etc. A resistive-capacitive divider and a Rogowski coil are adopted in measurement; ADLINK corporation's PXI chips are used in data acquisition; data transmission system, condition monitoring and data analysis are developed by LabVIEW. This system can realize on-line monitoring and data analysis for the repetitive pulsed power source. (authors)

  15. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source

    International Nuclear Information System (INIS)

    Kaehle, Stephan

    2009-01-01

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10 16 W/cm 2 dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K α radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K α production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K α radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density [de

  16. Haben repetitive DNA-Sequenzen biologische Funktionen?

    Science.gov (United States)

    John, Maliyakal E.; Knöchel, Walter

    1983-05-01

    By DNA reassociation kinetics it is known that the eucaryotic genome consists of non-repetitive DNA, middle-repetitive DNA and highly repetitive DNA. Whereas the majority of protein-coding genes is located on non-repetitive DNA, repetitive DNA forms a constitutive part of eucaryotic DNA and its amount in most cases equals or even substantially exceeds that of non-repetitive DNA. During the past years a large body of data on repetitive DNA has accumulated and these have prompted speculations ranging from specific roles in the regulation of gene expression to that of a selfish entity with inconsequential functions. The following article summarizes recent findings on structural, transcriptional and evolutionary aspects and, although by no means being proven, some possible biological functions are discussed.

  17. Characterization and distribution of repetitive elements in association with genes in the human genome.

    Science.gov (United States)

    Liang, Kai-Chiang; Tseng, Joseph T; Tsai, Shaw-Jenq; Sun, H Sunny

    2015-08-01

    -associated repetitive elements in the human genome. Our data showed distinct genes associated with different kinds of repetitive element and implied such combination may shape the function of these genes. Aside from the conventional view of these elements in genome evolution, results from this study offer a systemic review to facilitate exploitation of these elements in genome function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Repetitive nanosecond electron accelerators type URT-1 for radiation technology

    Science.gov (United States)

    Sokovnin, S. Yu.; Balezin, M. E.

    2018-03-01

    The electron accelerator URT-1М-300 for mobile installation was created for radiation disinfecting to correct drawbacks that were found the URT-1M electron accelerator operation (the accelerating voltage up to 1 МV, repetition rate up to 300 pps, electron beam size 400 × 100 mm, the pulse width about 100 ns). Accelerator configuration was changed that allowed to reduce significantly by 20% tank volume with oil where is placed the system of formation high-voltage pulses, thus the average power of the accelerator is increased by 6 times at the expense of increase in pulses repetition rate. Was created the system of the computerized monitoring parameters (output parameters and thermal mode) and remote control of the accelerator (charge voltage, pulse repetition rate), its elements and auxiliary systems (heat of the thyratron, vacuum system), the remote control panel is connected to the installation by the fiber-optical channel, what lightens the work for service personnel. For generating an electron beam up to 400 mm wide there are used metal- ceramic] and metal-dielectric cold cathodes of several emission elements (plates) with a non-uniform distribution of the electron beam current density on the output foil ± 15%. It was found that emission drop of both type of cathodes, during the operation at the high repetition rate (100 pps) is substantial at the beginning of the process, and then proceeds rather slowly that allows for continuous operation up to 40 h. Experiments showed that linear dependence of the voltage and a signal from the pin-diode remains within the range of the charge voltage 45-65 kV. Thus, voltage increases from 690 to 950 kV, and the signal from the pin-diode - from (2,8-4,6)*104 Gy/s. It allows to select electron energy quite precisely with consideration of the radiation technology requirements.

  19. REPETITION AS A SPECIAL TYPE OF SYNTACTIC RELATIONS IN REPRESENTED SPEECH: BASED ON THE PROSE BY MARINA TSVETAEVA

    Directory of Open Access Journals (Sweden)

    Olga Pavlovna Puchinina

    2017-03-01

    Full Text Available The author studies the peculiarities of repetition, being one of the ways to build syntactic relations in the represented speech structure, based on the prose by Marina Tsvetaeva. The article describes the different types of repetitions, their distinctive features and frequency of usage in the studied tests. The author describes different types of repetitions in the studied cases of represented speech from the point of view of their position. Repetition occurs at the beginning, end of sentences, beginning and end of a statement or paragraph, end of a statement and beginning of the next one; lexical items may be repeated in the middle of a statement. The morphology of repetitions, i.e., the way by what parts of speech the repeated words and structures are expressed, is of interest from the point of view of functional grammar. The author notes that Tsvetaeva repeats different parts of speech: conjunctions, prepositions, particles, nouns, pronouns, adverbs, numerals, verbs, modal words or a combination of two words. Moreover, due to her special intention, Tsvetaeva intensifies repetition through particular phonetic devices, such as alliteration, rhyme and rhythm, which make her prosaic works sound poetic. Purpose. The article is devoted to the topic of rendering another person’s speech, as it continues to be one of the most important issues of modern linguistics. The subject of analysis is repetition and its different types in the structure of represented speech on the material of prose texts by Marina Tsvetaeva. The author’s aims is to reveal the way these types of repetition (lexical, syntactic, semantic ones function in the structure of represented speech and what effect is achieved with their help. Methodology. The research has been conducted using the continuous sampling method and the quantitative estimation method, aimed to identify the frequency of using different types of repetition and repeated parts of speech and constructions in the

  20. High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier.

    Science.gov (United States)

    Andersen, T V; Schmidt, O; Bruchmann, C; Limpert, J; Aguergaray, C; Cormier, E; Tünnermann, A

    2006-05-29

    We report on the generation of high energy femtosecond pulses at 1 MHz repetition rate from a fiber laser pumped optical parametric amplifier (OPA). Nonlinear bandwidth enhancement in fibers provides the intrinsically synchronized signal for the parametric amplifier. We demonstrate large tunability extending from 700 nm to 1500 nm of femtosecond pulses with pulse energies as high as 1.2 muJ when the OPA is seeded by a supercontinuum generated in a photonic crystal fiber. Broadband amplification over more than 85 nm is achieved at a fixed wavelength. Subsequent compression in a prism sequence resulted in 46 fs pulses. With an average power of 0.5 W these pulses have a peak-power above 10 MW. In particular, the average power and pulse energy scalability of both involved concepts, the fiber laser and the parametric amplifier, will enable easy up-scaling to higher powers.

  1. A dispersion-balanced Discrete Fourier Transform of repetitive pulse sequences using temporal Talbot effect

    Science.gov (United States)

    Fernández-Pousa, Carlos R.

    2017-11-01

    We propose a processor based on the concatenation of two fractional temporal Talbot dispersive lines with balanced dispersion to perform the DFT of a repetitive electrical sequence, for its use as a controlled source of optical pulse sequences. The electrical sequence is used to impart the amplitude and phase of a coherent train of optical pulses by use of a modulator placed between the two Talbot lines. The proposal has been built on a representation of the action of fractional Talbot effect on repetitive pulse sequences and a comparison with related results and proposals. It is shown that the proposed system is reconfigurable within a few repetition periods, has the same processing rate as the input optical pulse train, and requires the same technical complexity in terms of dispersion and pulse width as the standard, passive pulse-repetition rate multipliers based on fractional Talbot effect.

  2. Application of a high-repetition-rate laser diagnostic system for single-cycle-resolved imaging in internal combustion engines.

    Science.gov (United States)

    Hult, Johan; Richter, Mattias; Nygren, Jenny; Aldén, Marcus; Hultqvist, Anders; Christensen, Magnus; Johansson, Bengt

    2002-08-20

    High-repetition-rate laser-induced fluorescence measurements of fuel and OH concentrations in internal combustion engines are demonstrated. Series of as many as eight fluorescence images, with a temporal resolution ranging from 10 micros to 1 ms, are acquired within one engine cycle. A multiple-laser system in combination with a multiple-CCD camera is used for cycle-resolved imaging in spark-ignition, direct-injection stratified-charge, and homogeneous-charge compression-ignition engines. The recorded data reveal unique information on cycle-to-cycle variations in fuel transport and combustion. Moreover, the imaging system in combination with a scanning mirror is used to perform instantaneous three-dimensional fuel-concentration measurements.

  3. Word Recognition during Reading: The Interaction between Lexical Repetition and Frequency

    Science.gov (United States)

    Lowder, Matthew W.; Choi, Wonil; Gordon, Peter C.

    2013-01-01

    Memory studies utilizing long-term repetition priming have generally demonstrated that priming is greater for low-frequency words than for high-frequency words and that this effect persists if words intervene between the prime and the target. In contrast, word-recognition studies utilizing masked short-term repetition priming typically show that the magnitude of repetition priming does not differ as a function of word frequency and does not persist across intervening words. We conducted an eye-tracking while reading experiment to determine which of these patterns more closely resembles the relationship between frequency and repetition during the natural reading of a text. Frequency was manipulated using proper names that were high-frequency (e.g., Stephen) or low-frequency (e.g., Dominic). The critical name was later repeated in the sentence, or a new name was introduced. First-pass reading times and skipping rates on the critical name revealed robust repetition-by-frequency interactions such that the magnitude of the repetition-priming effect was greater for low-frequency names than for high-frequency names. In contrast, measures of later processing showed effects of repetition that did not depend on lexical frequency. These results are interpreted within a framework that conceptualizes eye-movement control as being influenced in different ways by lexical- and discourse-level factors. PMID:23283808

  4. Transient thermal stress wave and vibrational analyses of a thin diamond crystal for X-ray free-electron lasers under high-repetition-rate operation.

    Science.gov (United States)

    Yang, Bo; Wang, Songwei; Wu, Juhao

    2018-01-01

    High-brightness X-ray free-electron lasers (FELs) are perceived as fourth-generation light sources providing unprecedented capabilities for frontier scientific researches in many fields. Thin crystals are important to generate coherent seeds in the self-seeding configuration, provide precise spectral measurements, and split X-ray FEL pulses, etc. In all of these applications a high-intensity X-ray FEL pulse impinges on the thin crystal and deposits a certain amount of heat load, potentially impairing the performance. In the present paper, transient thermal stress wave and vibrational analyses as well as transient thermal analysis are carried out to address the thermomechanical issues for thin diamond crystals, especially under high-repetition-rate operation of an X-ray FEL. The material properties at elevated temperatures are considered. It is shown that, for a typical FEL pulse depositing tens of microjoules energy over a spot of tens of micrometers in radius, the stress wave emission is completed on the tens of nanoseconds scale. The amount of kinetic energy converted from a FEL pulse can reach up to ∼10 nJ depending on the layer thickness. Natural frequencies of a diamond plate are also computed. The potential vibrational amplitude is estimated as a function of frequency. Due to the decreasing heat conductivity with increasing temperature, a runaway temperature rise is predicted for high repetition rates where the temperature rises abruptly after ratcheting up to a point of trivial heat damping rate relative to heat deposition rate.

  5. Repetition and lag effects in movement recognition.

    Science.gov (United States)

    Hall, C R; Buckolz, E

    1982-03-01

    Whether repetition and lag improve the recognition of movement patterns was investigated. Recognition memory was tested for one repetition, two-repetitions massed, and two-repetitions distributed with movement patterns at lags of 3, 5, 7, and 13. Recognition performance was examined both immediately afterwards and following a 48 hour delay. Both repetition and lag effects failed to be demonstrated, providing some support for the claim that memory is unaffected by repetition at a constant level of processing (Craik & Lockhart, 1972). There was, as expected, a significant decrease in recognition memory following the retention interval, but this appeared unrelated to repetition or lag.

  6. Interest Rate Demands and Television Viewing-Is a Single Exposure More Influential Than Routine Viewing?

    Science.gov (United States)

    Hetsroni, Amir; Reizer, Abira; Ben Zion, Uri

    2017-04-01

    This study examined the impact of media consumption, and particularly exposure to television, on decisions regarding interest rate demands. One hundred and fifty-four participants were randomly divided into two groups: in the manipulation group, participants were exposed to a news clip about an Iranian nuclear attack on Israel, whereas in the control group, the participants were not exposed to the film. Both groups filled a questionnaires regarding their interest rate requirements in different situations, their media conception behaviors, and demographic questionnaires. Frequent routine viewing increased the interest rate demands only among participants in the manipulation group, but the manipulation itself did not have a significant effect on interest rate demands. The results are explained in terms of cultivation theory.

  7. Prediction of the Maximum Number of Repetitions and Repetitions in Reserve From Barbell Velocity.

    Science.gov (United States)

    García-Ramos, Amador; Torrejón, Alejandro; Feriche, Belén; Morales-Artacho, Antonio J; Pérez-Castilla, Alejandro; Padial, Paulino; Haff, Guy Gregory

    2018-03-01

    To provide 2 general equations to estimate the maximum possible number of repetitions (XRM) from the mean velocity (MV) of the barbell and the MV associated with a given number of repetitions in reserve, as well as to determine the between-sessions reliability of the MV associated with each XRM. After determination of the bench-press 1-repetition maximum (1RM; 1.15 ± 0.21 kg/kg body mass), 21 men (age 23.0 ± 2.7 y, body mass 72.7 ± 8.3 kg, body height 1.77 ± 0.07 m) completed 4 sets of as many repetitions as possible against relative loads of 60%1RM, 70%1RM, 80%1RM, and 90%1RM over 2 separate sessions. The different loads were tested in a randomized order with 10 min of rest between them. All repetitions were performed at the maximum intended velocity. Both the general equation to predict the XRM from the fastest MV of the set (CV = 15.8-18.5%) and the general equation to predict MV associated with a given number of repetitions in reserve (CV = 14.6-28.8%) failed to provide data with acceptable between-subjects variability. However, a strong relationship (median r 2  = .984) and acceptable reliability (CV  .85) were observed between the fastest MV of the set and the XRM when considering individual data. These results indicate that generalized group equations are not acceptable methods for estimating the XRM-MV relationship or the number of repetitions in reserve. When attempting to estimate the XRM-MV relationship, one must use individualized relationships to objectively estimate the exact number of repetitions that can be performed in a training set.

  8. If you negate, you may forget: negated repetitions impair memory compared with affirmative repetitions.

    Science.gov (United States)

    Mayo, Ruth; Schul, Yaacov; Rosenthal, Meytal

    2014-08-01

    One of the most robust laws of memory is that repeated activation improves memory. Our study shows that the nature of repetition matters. Specifically, although both negated repetition and affirmative repetition improve memory compared with no repetition, negated repetition hinders memory compared with affirmative repetition. After showing participants different entities, we asked them about features of these entities, leading to either "yes" or "no" responses. Our findings show that correctly negating an incorrect feature of an entity elicits an active forgetting effect compared with correctly affirming its true features. For example, after seeing someone drink a glass of white wine, answering "no" to "was it red wine?" may lead one to greater memory loss of the individual drinking wine at all compared with answering "yes" to "was it white wine?" We find this negation-induced forgetting effect in 4 experiments that differ in (a) the meaning given for the negation, (b) the type of stimuli (visual or verbal), and (c) the memory measure (recognition or free recall). We discuss possible underlying mechanisms and offer theoretical and applied implications of the negation-induced forgetting effect in relation to other known inhibition effects. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Optical identification of sea-mines - Gated viewing three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens

    2005-01-01

    A gated viewing high accuracy mono-static laser radar has been developed for the purpose of improving the optical underwater sea-mine identification handled by the Navy. In the final stage of the sea-mine detection, classification and identification process the Navy applies a remote operated...... vehicle for optical identification of the bottom seamine. The experimental results of the thesis indicate that replacing the conventional optical video and spotlight system applied by the Navy with the gated viewing two- and three-dimensional laser radar can improve the underwater optical sea...... of the short laser pulses (0.5 ns), the high laser pulse repetition rate (32.4 kHz), the fast gating camera (0.2 ns), the short camera delay steps (0.1 ns), the applied optical single mode fiber, and the applied algorithm for three-dimensional imaging. The gated viewing laser radar system configuration...

  10. ReRep: Computational detection of repetitive sequences in genome survey sequences (GSS

    Directory of Open Access Journals (Sweden)

    Alves-Ferreira Marcelo

    2008-09-01

    Full Text Available Abstract Background Genome survey sequences (GSS offer a preliminary global view of a genome since, unlike ESTs, they cover coding as well as non-coding DNA and include repetitive regions of the genome. A more precise estimation of the nature, quantity and variability of repetitive sequences very early in a genome sequencing project is of considerable importance, as such data strongly influence the estimation of genome coverage, library quality and progress in scaffold construction. Also, the elimination of repetitive sequences from the initial assembly process is important to avoid errors and unnecessary complexity. Repetitive sequences are also of interest in a variety of other studies, for instance as molecular markers. Results We designed and implemented a straightforward pipeline called ReRep, which combines bioinformatics tools for identifying repetitive structures in a GSS dataset. In a case study, we first applied the pipeline to a set of 970 GSSs, sequenced in our laboratory from the human pathogen Leishmania braziliensis, the causative agent of leishmaniosis, an important public health problem in Brazil. We also verified the applicability of ReRep to new sequencing technologies using a set of 454-reads of an Escheria coli. The behaviour of several parameters in the algorithm is evaluated and suggestions are made for tuning of the analysis. Conclusion The ReRep approach for identification of repetitive elements in GSS datasets proved to be straightforward and efficient. Several potential repetitive sequences were found in a L. braziliensis GSS dataset generated in our laboratory, and further validated by the analysis of a more complete genomic dataset from the EMBL and Sanger Centre databases. ReRep also identified most of the E. coli K12 repeats prior to assembly in an example dataset obtained by automated sequencing using 454 technology. The parameters controlling the algorithm behaved consistently and may be tuned to the properties

  11. Repetitive Questioning Exasperates Caregivers

    Directory of Open Access Journals (Sweden)

    R. C. Hamdy MD

    2018-01-01

    Full Text Available Repetitive questioning is due to an impaired episodic memory and is a frequent, often presenting, problem in patients with Alzheimer’s disease (amnestic type. It is due to the patients’ difficulties learning new information, retaining it, and recalling it, and is often aggravated by a poor attention span and easy distractibility. A number of factors may trigger and maintain repetitive questioning. Caregivers should try to identify and address these triggers. In the case discussion presented, it is due to the patient’s concerns about her and her family’s safety triggered by watching a particularly violent movie aired on TV. What went wrong in the patient/caregiver interaction and how it could have been avoided or averted are explored. Also reviewed are the impact of repetitive questioning, the challenges it raises for caregivers, and some effective intervention strategies that may be useful to diffuse the angst that caregivers experience with repetitive questioning.

  12. Repetitive low-frequency stimulation reduces epileptiform synchronization in limbic neuronal networks.

    Science.gov (United States)

    D'Arcangelo, G; Panuccio, G; Tancredi, V; Avoli, M

    2005-01-01

    reduces the intensity and spatial extent of the IOS changes that accompany ictal synchronization in an in vitro slice preparation. This conclusion supports the view that repetitive stimulation may represent a potential therapeutic tool for controlling seizures in patients with pharmaco-resistant epileptic disorders.

  13. Computer-Related Repetitive Stress Injuries

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Computer-Related Repetitive Stress Injuries KidsHealth / For Parents / Computer-Related Repetitive Stress Injuries What's in this article? ...

  14. The role of short-term memory impairment in nonword repetition, real word repetition, and nonword decoding: A case study.

    Science.gov (United States)

    Peter, Beate

    2018-01-01

    In a companion study, adults with dyslexia and adults with a probable history of childhood apraxia of speech showed evidence of difficulty with processing sequential information during nonword repetition, multisyllabic real word repetition and nonword decoding. Results suggested that some errors arose in visual encoding during nonword reading, all levels of processing but especially short-term memory storage/retrieval during nonword repetition, and motor planning and programming during complex real word repetition. To further investigate the role of short-term memory, a participant with short-term memory impairment (MI) was recruited. MI was confirmed with poor performance during a sentence repetition and three nonword repetition tasks, all of which have a high short-term memory load, whereas typical performance was observed during tests of reading, spelling, and static verbal knowledge, all with low short-term memory loads. Experimental results show error-free performance during multisyllabic real word repetition but high counts of sequence errors, especially migrations and assimilations, during nonword repetition, supporting short-term memory as a locus of sequential processing deficit during nonword repetition. Results are also consistent with the hypothesis that during complex real word repetition, short-term memory is bypassed as the word is recognized and retrieved from long-term memory prior to producing the word.

  15. Short-Pulse-Width Repetitively Q-Switched ~2.7-μm Er:Y2O3 Ceramic Laser

    Directory of Open Access Journals (Sweden)

    Xiaojing Ren

    2017-11-01

    Full Text Available A short-pulse-width repetitively Q-switched 2.7-μm Er:Y2O3 ceramic laser is demonstrated using a specially designed mechanical switch, a metal plate carved with slits of both slit-width and duty-cycle optimized. With a 20% transmission output coupler, stable pulse trains with durations (full-width at half-maximum, FWHM of 27–38 ns were generated with a repetition rate within the range of 0.26–4 kHz. The peak power at a 0.26 kHz repetition rate was ~3 kW.

  16. Optimizing strategy for repetitive construction projects within multi-mode resources

    Directory of Open Access Journals (Sweden)

    Remon Fayek Aziz

    2013-03-01

    Full Text Available Estimating tender data for specific project is the most essential part in construction areas as of a contractor’s view such as: proposed project duration with corresponding gross value and cash flows. Cash flow analysis of construction projects has a long history and has been an important topic in construction management. Determination of project cash flows is very sensitive, especially for repetitive construction projects. This paper focuses on how to calculate tender data for repetitive construction projects such as: project duration, project cost, project/bid price, project cash flows, project maximum working capital and project net present value that is equivalent to net profit at the beginning of the project. A simplified multi-objective optimization formulation will be presented that creates best tender data to contractor comparing with more feasible options that are generated from multi-mode resources in a given project. This mathematical formulation is intended to give more scenarios which provide a practical support for typical construction contractors who need to optimize resource utilization in order to minimize project duration, project/bid price and project maximum working capital while maximizing its net present value simultaneously. At the end of the paper, an illustrative example will be presented to demonstrate the applications of proposed technique to an optimization expressway of repetitive construction project.

  17. Synergy Repetition Training versus Task Repetition Training in Acquiring New Skill.

    Science.gov (United States)

    Patel, Vrajeshri; Craig, Jamie; Schumacher, Michelle; Burns, Martin K; Florescu, Ionut; Vinjamuri, Ramana

    2017-01-01

    Traditionally, repetitive practice of a task is used to learn a new skill, exhibiting as immediately improved performance. Research suggests, however, that a more experience-based rather than exposure-based training protocol may allow for better transference of the skill to related tasks. In synergy-based motor control theory, fundamental motor skills, such as hand grasping, are represented with a synergy subspace that captures essential motor patterns. In this study, we propose that motor-skill learning through synergy-based mechanisms may provide advantages over traditional task repetition learning. A new task was designed to highlight the range of motion and dexterity of the human hand. Two separate training strategies were tested in healthy subjects: task repetition training and synergy training versus a control. All three groups showed improvements when retested on the same task. When tested on a similar, but different set of tasks, only the synergy group showed improvements in accuracy (9.27% increase) compared to the repetition (3.24% decline) and control (3.22% decline) groups. A kinematic analysis revealed that although joint angular peak velocities decreased, timing benefits stemmed from the initial feed-forward portion of the task (reaction time). Accuracy improvements may have derived from general improved coordination among the four involved fingers. These preliminary results warrant further investigation of synergy-based motor training in healthy individuals, as well as in individuals undergoing hand-based rehabilitative therapy.

  18. Choppers to optimise the repetition rate multiplication technique on a direct geometry neutron chopper spectrometer

    International Nuclear Information System (INIS)

    Vickery, A.; Deen, P. P.

    2014-01-01

    In recent years the use of repetition rate multiplication (RRM) on direct geometry neutron spectrometers has been established and is the common mode of operation on a growing number of instruments. However, the chopper configurations are not ideally optimised for RRM with a resultant 100 fold flux difference across a broad wavelength band. This paper presents chopper configurations that will produce a relative constant (RC) energy resolution and a relative variable (RV) energy resolution for optimised use of RRM. The RC configuration provides an almost uniform ΔE/E for all incident wavelengths and enables an efficient use of time as the entire dynamic range is probed with equivalent statistics, ideal for single shot measurements of transient phenomena. The RV energy configuration provides an almost uniform opening time at the sample for all incident wavelengths with three orders of magnitude in time resolution probed for a single European Spallation Source (ESS) period, which is ideal to probe complex relaxational behaviour. These two chopper configurations have been simulated for the Versatile Optimal Resolution direct geometry spectrometer, VOR, that will be built at ESS

  19. High power, repetitive stacked Blumlein pulse generators

    Energy Technology Data Exchange (ETDEWEB)

    Davanloo, F; Borovina, D L; Korioth, J L; Krause, R K; Collins, C B [Univ. of Texas at Dallas, Richardson, TX (United States). Center for Quantum Electronics; Agee, F J [US Air Force Phillips Lab., Kirtland AFB, NM (United States); Kingsley, L E [US Army CECOM, Ft. Monmouth, NJ (United States)

    1997-12-31

    The repetitive stacked Blumlein pulse power generators developed at the University of Texas at Dallas consist of several triaxial Blumleins stacked in series at one end. The lines are charged in parallel and synchronously commuted with a single switch at the other end. In this way, relatively low charging voltages are multiplied to give a high discharge voltage across an arbitrary load. Extensive characterization of these novel pulsers have been performed over the past few years. Results indicate that they are capable of producing high power waveforms with rise times and repetition rates in the range of 0.5-50 ns and 1-300 Hz, respectively, using a conventional thyratron, spark gap, or photoconductive switch. The progress in the development and use of stacked Blumlein pulse generators is reviewed. The technology and the characteristics of these novel pulsers driving flash x-ray diodes are discussed. (author). 4 figs., 5 refs.

  20. Exact Repetition as Input Enhancement in Second Language Acquisition.

    Science.gov (United States)

    Jensen, Eva Dam; Vinther, Thora

    2003-01-01

    Reports on two studies on input enhancement used to support learners' selection of focus of attention in Spanish second language listening material. Input consisted of video recordings of dialogues between native speakers. Exact repetition and speech rate reduction were examined for effect on comprehension, acquisition of decoding strategies, and…

  1. The effect of the pulse repetition rate on the fast ionization wave discharge

    Science.gov (United States)

    Huang, Bang-Dou; Carbone, Emile; Takashima, Keisuke; Zhu, Xi-Ming; Czarnetzki, Uwe; Pu, Yi-Kang

    2018-06-01

    The effect of the pulse repetition rate (PRR) on the generation of high energy electrons in a fast ionization wave (FIW) discharge is investigated by both experiment and modelling. The FIW discharge is driven by nanosecond high voltage pulses and is generated in helium with a pressure of 30 mbar. The axial electric field (E z ), as the driven force of high energy electron generation, is strongly influenced by PRR. Both the measurement and the model show that, during the breakdown, the peak value of E z decreases with the PRR, while after the breakdown, the value of E z increases with the PRR. The electron energy distribution function (EEDF) is calculated with a model similar to Boeuf and Pitchford (1995 Phys. Rev. E 51 1376). It is found that, with a low value of PRR, the EEDF during the breakdown is strongly non-Maxwellian with an elevated high energy tail, while the EEDF after the breakdown is also non-Maxwellian but with a much depleted population of high energy electrons. However, with a high value of PRR, the EEDF is Maxwellian-like without much temporal variation both during and after the breakdown. With the calculated EEDF, the temporal evolution of the population of helium excited species given by the model is in good agreement with the measured optical emission, which also depends critically on the shape of the EEDF.

  2. Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Buttafava, Mauro, E-mail: mauro.buttafava@polimi.it; Boso, Gianluca; Ruggeri, Alessandro; Tosi, Alberto [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Dalla Mora, Alberto [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy)

    2014-08-15

    We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor.

  3. Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

    International Nuclear Information System (INIS)

    Buttafava, Mauro; Boso, Gianluca; Ruggeri, Alessandro; Tosi, Alberto; Dalla Mora, Alberto

    2014-01-01

    We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor

  4. The Multidisk Diode-Pumped High Power Yb:YAG Laser Amplifier of High-Intensity Laser System with 1 kHz Repetition Rate

    Science.gov (United States)

    Kuptsov, G. V.; Petrov, V. V.; Petrov, V. A.; Laptev, A. V.; Kirpichnikov, A. V.; Pestryakov, E. V.

    2018-04-01

    The source of instabilities in the multidisk diode-pumped high power Yb:YAG laser amplifier with cryogenic closed-loop cooling in the laser amplification channel of the high-intensity laser system with 1 kHz repetition rate was determined. Dissected copper mounts were designed and used to suppress instabilities and to achieve repeatability of the system. The equilibrium temperature dependency of the active elements on average power was measured. The seed laser for the multidisk amplifier was numerically simulated and designed to allow one to increase pulses output energy after the amplifier up to 500 mJ.

  5. Design study of a low-emittance high-repetition rate thermionic rf gun

    Directory of Open Access Journals (Sweden)

    A. Opanasenko

    2017-05-01

    Full Text Available We propose a novel gridless continuous-wave radiofrequency (rf thermionic gun capable of generating nC ns electron bunches with a rms normalized slice emittance close to the thermal level of 0.3 mm mrad. In order to gate the electron emission, an externally heated thermionic cathode is installed into a stripline-loop conductor. Two high-voltage pulses propagating towards each other in the stripline-loop overlap in the cathode region and create a quasielectrostatic field gating the electron emission. The repetition rate of pulses is variable and can reach up to one MHz with modern solid-state pulsers. The stripline attached to a rf gun cavity wall has with the wall a common aperture that allows the electrons to be injected into the rf cavity for further acceleration. Thanks to this innovative gridless design, simulations suggest that the bunch emittance is approximately at the thermal level after the bunch injection into the cavity provided that the geometry of the cathode and aperture are properly designed. Specifically, a concave cathode is adopted to imprint an Ƨ-shaped distribution onto the beam transverse phase-space to compensate for an S-shaped beam distribution created by the spherical aberration of the aperture-cavity region. In order to compensate for the energy spread caused by rf fields of the rf gun cavity, a 3rd harmonic cavity is used. A detailed study of the electrodynamics of the stripline and rf gun cavity as well as the beam optics and bunch dynamics are presented.

  6. All-fiber interferometer-based repetition-rate stabilization of mode-locked lasers to 10-14-level frequency instability and 1-fs-level jitter over 1  s.

    Science.gov (United States)

    Kwon, Dohyeon; Kim, Jungwon

    2017-12-15

    We report on all-fiber Michelson interferometer-based repetition-rate stabilization of femtosecond mode-locked lasers down to 1.3×10 -14 frequency instability and 1.4 fs integrated jitter in a 1 s time scale. The use of a compactly packaged 10 km long single-mode fiber (SMF)-28 fiber link as a timing reference allows the scaling of phase noise at a 10 GHz carrier down to -80  dBc/Hz at 1 Hz Fourier frequency. We also tested a 500 m long low-thermal-sensitivity fiber as a reference and found that, compared to standard SMF-28 fiber, it can mitigate the phase noise divergence by ∼10  dB/dec in the 0.1-1 Hz Fourier frequency range. These results suggest that the use of a longer low-thermal-sensitivity fiber may achieve sub-femtosecond integrated timing jitter with sub-10 -14 -level frequency instability in repetition rate by a simple and robust all-fiber-photonic method.

  7. Repetitive Questioning II

    Directory of Open Access Journals (Sweden)

    R. C. Hamdy MD

    2018-02-01

    Full Text Available Repetitive questioning is a major problem for caregivers, particularly taxing if they are unable to recognize and understand the reasons why their loved one keeps asking the same question over and over again. Caregivers may be tempted to believe that the patient does not even try to remember the answer given or is just getting obnoxious. This is incorrect. Repetitive questioning is due to the underlying disease: The patient’s short term memory is impaired and he is unable to register, encode, retain and retrieve the answer. If he is concerned about a particular topic, he will keep asking the same question over and over again. To the patient each time she asks the question, it is as if she asked it for the first time. Just answering repetitive questioning by providing repeatedly the same answer is not sufficient. Caregivers should try to identify the underlying cause for this repetitive questioning. In an earlier case study, the patient was concerned about her and her family’s safety and kept asking whether the doors are locked. In this present case study, the patient does not know how to handle the awkward situation he finds himself in. He just does not know what to do. He is not able to adjust to the new unexpected situation. So he repeatedly wants to reassure himself that he is not intruding by asking the same question over and over again. We discuss how the patient’s son-in-law could have avoided this situation and averted the catastrophic ending.

  8. Basal View Reference Photographs for Nasolabial Appearance Rating in Unilateral Cleft Lip and Palate.

    Science.gov (United States)

    Rubin, Marcie S; Lowe, Kristen M; Clouston, Sean; Shetye, Pradip R; Warren, Stephen M; Grayson, Barry H

    2015-07-01

    The Asher-McDade system is a 5-point ordinal scale frequently used to rate the components of nasolabial appearance, including nasal form and nasal symmetry, in unilateral cleft lip and palate. Although reference photographs illustrating this scale have been identified for the frontal and right profile view, no reference photographs exist for the basal view. The aim of this study was to identify reference photographs for nasal form and nasal symmetry from the basal view to illustrate this scale and facilitate its use. Four raters assessed nasolabial appearance (form and symmetry) on basal view photographs of 50 children (average age 8 years) with a repaired cleft lip. Intraclass correlation coefficients show fair to moderate inter-rater reliability. Cronbach α indicated strong agreement between raters (0.77 nasal form; 0.78 nasal symmetry; 0.80 overall), along with low duplicate measurement error and strong internal consistency between the measures. The photographs with the highest agreement among raters were selected to illustrate each point on the 5-point scale for nasal form and for nasal symmetry, resulting in the selection of 10 reference photographs. The basal view reference photograph set developed from this study may complement existing reference photograph sets for other views and facilitate rating tasks.

  9. Ultrafast high-repetition imaging of fuel sprays using picosecond fiber laser.

    Science.gov (United States)

    Purwar, Harsh; Wang, Hongjie; Tang, Mincheng; Idlahcen, Saïd; Rozé, Claude; Blaisot, Jean-Bernard; Godin, Thomas; Hideur, Ammar

    2015-12-28

    Modern diesel injectors operate at very high injection pressures of about 2000 bar resulting in injection velocities as high as 700 m/s near the nozzle outlet. In order to better predict the behavior of the atomization process at such high pressures, high-resolution spray images at high repetition rates must be recorded. However, due to extremely high velocity in the near-nozzle region, high-speed cameras fail to avoid blurring of the structures in the spray images due to their exposure time. Ultrafast imaging featuring ultra-short laser pulses to freeze the motion of the spray appears as an well suited solution to overcome this limitation. However, most commercial high-energy ultrafast sources are limited to a few kHz repetition rates. In the present work, we report the development of a custom-designed picosecond fiber laser generating ∼ 20 ps pulses with an average power of 2.5 W at a repetition rate of 8.2 MHz, suitable for high-speed imaging of high-pressure fuel jets. This fiber source has been proof tested by obtaining backlight images of diesel sprays issued from a single-orifice injector at an injection pressure of 300 bar. We observed a consequent improvement in terms of image resolution compared to standard white-light illumination. In addition, the compactness and stability against perturbations of our fiber laser system makes it particularly suitable for harsh experimental conditions.

  10. Contact heat-evoked temporal summation: tonic versus repetitive-phasic stimulation.

    Science.gov (United States)

    Granot, Michal; Granovsky, Yelena; Sprecher, Elliot; Nir, Rony-Reuven; Yarnitsky, David

    2006-06-01

    Temporal summation (TS) is usually evoked by repetitive mechanical or electrical stimuli, and less commonly by tonic heat pain. The present study aimed to examine the TS induction by repetitive-phasic versus tonic heat pain stimuli. Using 27 normal volunteers, we compared the extent of summation by three calculation methods: start-to-end pain rating difference, percent change, and double-logarithmic regression of successive ratings along the stimulation. Subjects were tested twice, and the reliability of each of the paradigms was obtained. In addition, personality factors related to pain catastrophizing and anxiety level were also correlated with the psychophysical results. Both paradigms induced significant TS, with similar increases for the repetitive-phasic and the tonic paradigms, as measured on 0-100 numerical pain scale (from 52.9+/-11.7 to 80.2+/-15.5, p<0.001; and from 38.5+/-13.3 to 75.8+/-18.3, p<0.001, respectively). The extent of summation was significantly correlated between the two paradigms, when calculated by absolute change (r=0.543, p=0.004) and by regression (r=0.438, p=0.025). Session-to-session variability was similar for both paradigms, relatively large, yet not biased. As with other psychophysical parameters, this poses some limitations on TS assessment in individual patients over time. The extent of TS induced by both paradigms was found to be associated with anxiety level and pain catastrophizing. Despite some dissimilarity between the repetitive-phasic and the tonic paradigms, the many similarities suggest that the two represent a similar physiological process, even if not precisely the same. Future clinical applications of these tests will determine the clinical relevance of the TS paradigms presented in this study.

  11. Accumulation effects in modulation spectroscopy with high-repetition-rate pulses: Recursive solution of optical Bloch equations

    Science.gov (United States)

    Osipov, Vladimir Al.; Pullerits, Tõnu

    2017-10-01

    Application of the phase-modulated pulsed light for advance spectroscopic measurements is the area of growing interest. The phase modulation of the light causes modulation of the signal. Separation of the spectral components of the modulations allows to distinguish the contributions of various interaction pathways. The lasers with high repetition rate used in such experiments can lead to appearance of the accumulation effects, which become especially pronounced in systems with long-living excited states. Recently it was shown that such accumulation effects can be used to evaluate parameters of the dynamical processes in the material. In this work we demonstrate that the accumulation effects are also important in the quantum characteristics measurements provided by modulation spectroscopy. In particular, we consider a model of quantum two-level system driven by a train of phase-modulated light pulses, organized in analogy with the two-dimensional spectroscopy experiments. We evaluate the harmonics' amplitudes in the fluorescent signal and calculate corrections appearing from the accumulation effects. We show that the corrections can be significant and have to be taken into account at analysis of experimental data.

  12. Repetitive learning control of continuous chaotic systems

    International Nuclear Information System (INIS)

    Chen Maoyin; Shang Yun; Zhou Donghua

    2004-01-01

    Combining a shift method and the repetitive learning strategy, a repetitive learning controller is proposed to stabilize unstable periodic orbits (UPOs) within chaotic attractors in the sense of least mean square. If nonlinear parts in chaotic systems satisfy Lipschitz condition, the proposed controller can be simplified into a simple proportional repetitive learning controller

  13. Novel porcine repetitive elements

    Directory of Open Access Journals (Sweden)

    Nonneman Dan J

    2006-12-01

    Full Text Available Abstract Background Repetitive elements comprise ~45% of mammalian genomes and are increasingly known to impact genomic function by contributing to the genomic architecture, by direct regulation of gene expression and by affecting genomic size, diversity and evolution. The ubiquity and increasingly understood importance of repetitive elements contribute to the need to identify and annotate them. We set out to identify previously uncharacterized repetitive DNA in the porcine genome. Once found, we characterized the prevalence of these repeats in other mammals. Results We discovered 27 repetitive elements in 220 BACs covering 1% of the porcine genome (Comparative Vertebrate Sequencing Initiative; CVSI. These repeats varied in length from 55 to 1059 nucleotides. To estimate copy numbers, we went to an independent source of data, the BAC-end sequences (Wellcome Trust Sanger Institute, covering approximately 15% of the porcine genome. Copy numbers in BAC-ends were less than one hundred for 6 repeat elements, between 100 and 1000 for 16 and between 1,000 and 10,000 for 5. Several of the repeat elements were found in the bovine genome and we have identified two with orthologous sites, indicating that these elements were present in their common ancestor. None of the repeat elements were found in primate, rodent or dog genomes. We were unable to identify any of the replication machinery common to active transposable elements in these newly identified repeats. Conclusion The presence of both orthologous and non-orthologous sites indicates that some sites existed prior to speciation and some were generated later. The identification of low to moderate copy number repetitive DNA that is specific to artiodactyls will be critical in the assembly of livestock genomes and studies of comparative genomics.

  14. Document retrieval on repetitive string collections.

    Science.gov (United States)

    Gagie, Travis; Hartikainen, Aleksi; Karhu, Kalle; Kärkkäinen, Juha; Navarro, Gonzalo; Puglisi, Simon J; Sirén, Jouni

    2017-01-01

    Most of the fastest-growing string collections today are repetitive, that is, most of the constituent documents are similar to many others. As these collections keep growing, a key approach to handling them is to exploit their repetitiveness, which can reduce their space usage by orders of magnitude. We study the problem of indexing repetitive string collections in order to perform efficient document retrieval operations on them. Document retrieval problems are routinely solved by search engines on large natural language collections, but the techniques are less developed on generic string collections. The case of repetitive string collections is even less understood, and there are very few existing solutions. We develop two novel ideas, interleaved LCPs and precomputed document lists , that yield highly compressed indexes solving the problem of document listing (find all the documents where a string appears), top- k document retrieval (find the k documents where a string appears most often), and document counting (count the number of documents where a string appears). We also show that a classical data structure supporting the latter query becomes highly compressible on repetitive data. Finally, we show how the tools we developed can be combined to solve ranked conjunctive and disjunctive multi-term queries under the simple [Formula: see text] model of relevance. We thoroughly evaluate the resulting techniques in various real-life repetitiveness scenarios, and recommend the best choices for each case.

  15. REPETITIVE STRENGTH AMONG STUDENTS OF AGE 14

    Directory of Open Access Journals (Sweden)

    Besim Halilaj

    2014-06-01

    Full Text Available The study involved 82 male students of the primary school “Qamil Ilazi” in Kaçanik-Kosovo.Four movement tests, which test the repetitive strength, were conducted: 1. Pull-up, 2. Sit-Up, 3. Back extension, 4. Push-up.The main goal of this study was to verify the actual motor status, respectively the component of the repetitive strength among students of age 14 of masculine gender. In addition to verifying the actual motor status, another objective was to verify the relationship between the variables employed.Basic statistical parameters show a distribution which is not significantly different from the normal distribution, yielded highly correlative values among the repetitive strength tests. Space factorization resulted in extracting two latent squares defined as repetitive strength of arms factor, and repetitive strength of body factor.

  16. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Science.gov (United States)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  17. Reject/repeat analysis and the effect prior film viewing has on a department's reject/repeat rate

    International Nuclear Information System (INIS)

    Clark, P.A.; Hogg, P.

    2003-01-01

    Purpose: Achieving cost-effectiveness within the NHS is an old initiative but one that has again been highlighted by recent government policies (The New NHS-Modern and Dependable, Stationary Office, London, 1997). It has been reiterated that it is the responsibility of individual Trusts to devise means to provide such a service. Reject/repeat analyses have long been the primary tool used to assess the cost-effectiveness of radiography departments (Quality Assurance in Diagnostic Radiology, WHO, Geneva, 1982). This research paper examines an in-house initiative (viewing patients' previous films) commonly employed in other Health Trusts in order to reduce departmental repeat/reject rates. Method: Three hundred orthopaedic patients with hip, knee and ankle prostheses were included in a reject/repeat analysis. The aim was to investigate whether or not viewing patient's previous relevant radiographs would be advantageous to the practicing radiographer. This was done through an audit cycle consisting of two audit periods each lasting for 3 months. The primary audit period recorded the baseline repeat/reject rate, with the secondary audit period recording the repeat/reject rate under an experimental condition of viewing the relevant radiographs. Results: The baseline audit revealed repeat rates of 33% in orthopaedic patients with hip, knee and ankle prostheses. The availability of prior film viewing to the radiographer reduced this repeat rate to 10.6%. Conclusion: Prior film viewing dramatically reduced the department's repeat/reject rate by 22.4%. This provides scope for significant patient dose reductions as well as reducing departmental film expenses. This is an underestimated initiative and should be used appropriately in routine clinical practice

  18. Laser diagnostic and therapy of dental caries: the clinic point of view

    International Nuclear Information System (INIS)

    Paiva, Priscila Faria

    2001-01-01

    Dental caries's diagnosis is a major dentistry problem from the clinic point of view. The laser beam on the region of 655 nm induces the fluorescence of the compounds present in the hard tissue, quantifying differences between sound and carious enamel and dentine. Diagnodent (Kavo, Germany), showed to be effective regarding dental caries's diagnosis in the present research sampling. The Er:YAG laser (Kavo Key Laser 2, Germany) performed efficient cavity preparations in caries lesions of I and V class type, using up energies that ranged from 300 mJ to 350 mJ with 4 Hz repetition rate for the enamel; and from 250 mJ to 300 mJ with 4 Hz repetition rate for the dentine, and with 80 mJ with 6 Hz of repetition rate for laser conditioning. In the Er:YAG laser preparations no patient was anesthetized even when there were deeper cavities, and the maximum degree of pain ( which ranged from 0 to 10) was 4. In the control group with conventional high-speed drill two patients were anesthetized and the maximum degree of pain was 7. Restorations performed by conventional method of composite were equally satisfying both in caries groups of I and V class type and in the control group. The laser application in the operative dentistry office as a new method of diagnosis and dental preparations should be a good alternative to the use of the conventional dental drill. Nevertheless, dentistry practice has a lot to improve from technology progress, as well as new researches on laser dentistry are necessary in a long term. New types of lasers will come about and will increasingly improve the dental practice assistance and procedures quality. (author)

  19. Dual-Comb Coherent Raman Spectroscopy with Lasers of 1-GHz Pulse Repetition Frequency

    OpenAIRE

    Mohler, Kathrin J.; Bohn, Bernhard J.; Yan, Ming; Hänsch, Theodor W.; Picqué, Nathalie

    2016-01-01

    We extend the technique of multiplex coherent Raman spectroscopy with two femtosecond mode-locked lasers to oscillators of a pulse repetition frequency of 1 GHz. We demonstrate spectra of liquids, which span 1100 cm$^{-1}$ of Raman shifts. At a resolution of 6 cm$^{-1}$, their measurement time may be as short as 5 microseconds for a refresh rate of 2 kHz. The waiting period between acquisitions is improved ten-fold compared to previous experiments with two lasers of 100-MHz repetition frequen...

  20. Relationship between redistribution on exercise thallium-201 scintigraphy and repetitive ventricular premature beats in patients with recent myocardial infarction

    International Nuclear Information System (INIS)

    Tsuji, H.; Iwasaka, T.; Sugiura, T.; Shimada, T.; Nakamori, H.; Kimura, Y.; Inada, M.

    1991-01-01

    The relationship between myocardial ischemia detected by exercise thallium-201 scintigraphy and repetitive ventricular premature beats (VPBs) during ambulatory monitoring was evaluated in 57 patients with recent myocardial infarction. Multivariate analysis was performed to obtain the relatively important factor related to repetitive VPBs with the use of the following variables: age, redistribution, left ventricular ejection fraction, serum potassium and magnesium concentration, QRS score, left ventricular aneurysm, and the number of diseased vessels. Thirty-five patients had redistribution, but only three of them had repetitive VPBs during exercise testing. The average heart rate before 79% of 398 episodes of repetitive VPBs during ambulatory monitoring was in the range of 56 to 70/min. These data indicate that most of repetitive VPBs during ambulatory monitoring were not provoked by exercise-induced acute myocardial ischemia. However, redistribution was found to be an important factor associated with repetitive VPBs. The electrical abnormality relating to a substrate characterized by chronic reversible ischemia may explain the association between redistribution and repetitive VPBs

  1. The Relationship Between Method of Viewing Lectures, Course Ratings, and Course Timing.

    Science.gov (United States)

    Burton, William B; Ma, Terence P; Grayson, Martha S

    2017-01-01

    In recent years, medical schools have provided students access to video recordings of course lectures, but few studies have investigated the impact of this on ratings of courses and teachers. This study investigated whether the method of viewing lectures was related to student ratings of the course and its components and whether the method used changed over time. Preclinical medical students indicated whether ratings of course lectures were based primarily on lecture attendance, video capture, or both. Students were categorized into Lecture, Video, or Both groups based on their responses to this question. The data consisted of 7584 student evaluations collected over 2 years. Students who attended live lectures rated the course and its components higher than students who only viewed the video or used both methods, although these differences were very small. Students increasingly watched lectures exclusively by video over time: in comparison with first-year students, second-year students were more likely to watch lectures exclusively by video; in comparison with students in the first half of the academic year, students in the second half of the academic year were more likely to watch lectures exclusively by video. With the increase in use of lecture video recordings across medical schools, attention must be paid to student attitudes regarding these methods.

  2. The Effect of Task Instructions on Students' Use of Repetition in Argumentative Discourse

    Science.gov (United States)

    Gilabert, Sandra; Garcia-Mila, Merce; Felton, Mark K.

    2013-11-01

    The reasoning belief of argumentum ad nauseam assumes that when someone repeats something often enough, he or she becomes more convincing. The present paper analyses the use of this strategy by seventh-grade students in an argumentation task. Sixty-five students (mean age: 12.2, SD = 0.4) from a public school in a mid-sized urban environment took part in the study. The students were asked to either argue to convince an opposing partner or argue to reach consensus with an opposing partner on three dilemmas that dealt with energy sources. Data were gathered according to a between-groups design that included one independent variable (argumentative goal: to convince vs. to reach consensus) and one dependent variable (the degree of argumentative repetitions). We predicted that in the condition to convince their partner, the students would use the repetition strategy more often in their attempts to be persuasive. Our findings show that the mean number of argumentative repetitions was significantly higher for the persuasion group for both of the most frequent argumentative structures (claim and claim data). The mean percentage of repeated claims for the persuasion condition was 86.2 vs. 69.0 for the consensus condition. For the claim data, the mean percentage for the persuasion group was 35.2 vs. 24.3 for the consensus group. Also, students in the persuasion group tended to repeat one idea many times rather than repeating many ideas a few times within the same argumentative structure. The results of our study support the hypothesis that the goal of the argumentative task mediates argumentative discourse and, more concretely, the rate of repetitions and the conceptual diversity of the statements. These differences in rates of repetition and conceptual diversity are related to the amount of learning produced by the instructional goal. We apply Mercer's idea that not all classroom argumentation tasks promote learning equally.

  3. RS-20 type repetitive generator with planar configuration of plasma opening switch

    Energy Technology Data Exchange (ETDEWEB)

    Agalakov, V P; Barinov, N U; Belenki, G S [Kurchatov Inst., Moscow (Russian Federation); and others

    1997-12-31

    The existing experience with the production of repetitive rate accelerators with a high peak power (in excess of 10{sup 10} W) and an average power above 50 kW makes it possible to resolve a number of physics and technology tasks which are connected with the reliability and life of the accelerator. The design and results on optimization of a simple plasma opening switch (POS) are discussed. The final design of the POS provided voltages of up to 2 MV and had a life of more than 105 pulses including 4 hours of continuous operation under 4 Hz repetition rate and wall plug power 65 kW. This unit was tested at the RS-20 type accelerator both at the Kurchatov Institute and at the Northwest Institute of Nuclear Technology in China. (author). 5 figs., 1 ref.

  4. Dual-comb coherent Raman spectroscopy with lasers of 1-GHz pulse repetition frequency.

    Science.gov (United States)

    Mohler, Kathrin J; Bohn, Bernhard J; Yan, Ming; Mélen, Gwénaëlle; Hänsch, Theodor W; Picqué, Nathalie

    2017-01-15

    We extend the technique of multiplex coherent Raman spectroscopy with two femtosecond mode-locked lasers to oscillators of a pulse repetition frequency of 1 GHz. We demonstrate a spectra of liquids, which span 1100  cm-1 of Raman shifts. At a resolution of 6  cm-1, their measurement time may be as short as 5 μs for a refresh rate of 2 kHz. The waiting period between acquisitions is improved 10-fold compared to previous experiments with two lasers of 100-MHz repetition frequencies.

  5. Semantic priming, not repetition priming, is to blame for false hearing.

    Science.gov (United States)

    Rogers, Chad S

    2017-08-01

    Contextual and sensory information are combined in speech perception. Conflict between the two can lead to false hearing, defined as a high-confidence misidentification of a spoken word. Rogers, Jacoby, and Sommers (Psychology and Aging, 27(1), 33-45, 2012) found that older adults are more susceptible to false hearing than are young adults, using a combination of semantic priming and repetition priming to create context. In this study, the type of context (repetition vs. sematic priming) responsible for false hearing was examined. Older and young adult participants read and listened to a list of paired associates (e.g., ROW-BOAT) and were told to remember the pairs for a later memory test. Following the memory test, participants identified words masked in noise that were preceded by a cue word in the clear. Targets were semantically associated to the cue (e.g., ROW-BOAT), unrelated to the cue (e.g., JAW-PASS), or phonologically related to a semantic associate of the cue (e.g., ROW-GOAT). How often each cue word and its paired associate were presented prior to the memory test was manipulated (0, 3, or 5 times) to test effects of repetition priming. Results showed repetitions had no effect on rates of context-based listening or false hearing. However, repetition did significantly increase sensory information as a basis for metacognitive judgments in young and older adults. This pattern suggests that semantic priming dominates as the basis for false hearing and highlights context and sensory information operating as qualitatively different bases for listening and metacognition.

  6. Direct writing of sub-wavelength ripples on silicon using femtosecond laser at high repetition rate

    International Nuclear Information System (INIS)

    Xie, Changxin; Li, Xiaohong; Liu, Kaijun; Zhu, Min; Qiu, Rong; Zhou, Qiang

    2016-01-01

    Graphical abstract: - Highlights: • The NSRs and DSRs are obtained on silicon surface. • With increasing direct writing speed, the NSRs suddenly changes and becomes the DSRs. • We develop a Sipe–Drude interference theory by considering the thermal excitation. - Abstract: The near sub-wavelength and deep sub-wavelength ripples on monocrystalline silicon were formed in air by using linearly polarized and high repetition rate femtosecond laser pulses (f = 76 MHz, λ = 800 nm, τ = 50 fs). The effects of laser pulse energy, direct writing speed and laser polarization on silicon surface morphology are studied. When the laser pulse energy is 2 nJ/pulse and the direct writing speed varies from 10 to 25 mm/s, the near sub-wavelength ripples (NSRs) with orientation perpendicular to the laser polarization are generated. While the direct writing speed reaches 30 mm/s, the direction of the obtained deep sub-wavelength ripples (DSRs) suddenly changes and becomes parallel to the laser polarization, rarely reported so far for femtosecond laser irradiation of silicon. Meanwhile, we extend the Sipe–Drude interference theory by considering the thermal excitation, and numerically calculate the efficacy factor for silicon irradiated by femtosecond laser pulses. The revised Sipe–Drude interference theoretical results show good agreement with the periods and orientations of sub-wavelength ripples.

  7. Repetition and Emotive Communication in Music Versus Speech

    Directory of Open Access Journals (Sweden)

    Elizabeth Hellmuth eMargulis

    2013-04-01

    Full Text Available Music and speech are often placed alongside one another as comparative cases. Their relative overlaps and disassociations have been well explored (e.g. Patel, 2010. But one key attribute distinguishing these two domains has often been overlooked: the greater preponderance of repetition in music in comparison to speech. Recent fMRI studies have shown that familiarity – achieved through repetition – is a critical component of emotional engagement with music (Pereira et al., 2011. If repetition is fundamental to emotional responses to music, and repetition is a key distinguisher between the domains of music and speech, then close examination of the phenomenon of repetition might help clarify the ways that music elicits emotion differently than speech.

  8. Reduction in interval cancer rates following the introduction of two-view mammography in the UK breast screening programme

    Science.gov (United States)

    Dibden, A; Offman, J; Parmar, D; Jenkins, J; Slater, J; Binysh, K; McSorley, J; Scorfield, S; Cumming, P; Liao, X-H; Ryan, M; Harker, D; Stevens, G; Rogers, N; Blanks, R; Sellars, S; Patnick, J; Duffy, S W

    2014-01-01

    Background: The introduction of two-view mammography at incident (subsequent) screens in the National Health Service Breast Screening Programme (NHSBSP) has led to an increased number of cancers detected at screen. However, the effect of two-view mammography on interval cancer rates has yet to be assessed. Methods: Routine screening and interval cancer data were collated from all screening programmes in the United Kingdom for women aged 50–64, screened between 1 April 2003 and 31 March 2005. Interval cancer rates were compared based on whether two-view mammography was in use at the last routine screen. Results: The reduction in interval cancers following screening using two-view mammography compared with one view was 0.68 per 1 000 women screened. Overall, this suggests the introduction of two-view mammography at incident screen was accompanied by a 15–20% reduction in interval cancer rates in the NHSBSP. Conclusion: The introduction of two-view mammography at incident screens is associated with a reduction in incidence of interval cancers. This is consistent with previous publications on a contemporaneous increase in screen-detected cancers. The results provide further evidence of the benefit of the use of two-view mammography at incident screens. PMID:24366303

  9. Feature-based motion control for near-repetitive structures

    NARCIS (Netherlands)

    Best, de J.J.T.H.

    2011-01-01

    In many manufacturing processes, production steps are carried out on repetitive structures which consist of identical features placed in a repetitive pattern. In the production of these repetitive structures one or more consecutive steps are carried out on the features to create the final product.

  10. Interspersion of highly repetitive DNA with single copy DNA in the genome of the red crab, Geryon quinquedens

    Energy Technology Data Exchange (ETDEWEB)

    Christie, N.T. (Univ. of Tennessee, Oak Ridge); Skinner, D.M.

    1979-02-01

    Kinetic analysis of the reassociation of 420 nucleotide (NT) long fragments has shown that essentially all of the repetitive sequences of the DNA of the red crab Geryon quinquedens are highly repetitive. There are negligible amounts of low and intermediate repetitive DNAs. Though atypical of most eukaryotes, this pattern has been observed in al other brachyurans (true crabs) studied. The major repetitive component is subdivided into short runs of 300 NT and longer runs of greater than 1200 NT while the minor component has an average sequence length of 400 NT. Both components reassociate at rates commonly observed for satellite DNAs. Unique among eukaryotes the organization of the genome includes single copy DNA contiguous to short runs (300 NT) of both repetitive components. Although patent satellites are not present, subsets of the repetitive DNA have been isolated by either restriction endonuclease digestion or by centrifugation in Ag/sup +/ or Hg/sup 2 +//Cs/sub 2/SO/sub 4/ density gradients.

  11. Relationship to carcinogenesis of repetitive low-dose radiation exposure

    International Nuclear Information System (INIS)

    Ootsuyama, Akira

    2016-01-01

    We studied the carcinogenic effects caused by repetitive irradiation at a low dose, which has received attention in recent years, and examined the experimental methods used to evaluate radiation-induced carcinogenesis. For this experiment, we selected a mouse with as few autochthonous cancers as possible. Skin cancer was selected as the target for analysis, because it is a rare cancer in mice. Beta-rays were selected as the radiation source. The advantage of using beta-rays is weaker penetration power into tissues, thus protecting organs, such as the digestive and hematogenous organs. The benefit of our experimental method is that only skin cancer requires monitoring, and it is possible to perform long-term experiments. The back skin of mice was exposed repetitively to beta-rays three times a week until the occurrence of cancer or death, and the dose per exposure ranged from 0.5 to 11.8 Gy. With the high-dose range (2.5-11.8 Gy), the latency period and carcinogenic rate were almost the same in each experimental group. When the dose was reduced to 1-1.5 Gy, the latency period increased, but the carcinogenic rate remained. When the dose was further reduced to 0.5 Gy, skin cancer never happened, even though we continued irradiation until death of the last mouse in this group. The lifespan of 0.5 Gy group mice was the same as that of the controls. We showed that the 0.5 Gy dose did not cause cancer, even in mice exposed repetitively throughout their life span, and thus refer to 0.5 Gy as the threshold-like dose. (author)

  12. Periodic structures on germanium induced by high repetition rate femtosecond laser

    Science.gov (United States)

    Lin, Xiaoming; Li, Xiaohong; Zhang, Yanbin; Xie, Changxin; Liu, Kaijun; Zhou, Qiang

    2018-05-01

    Laser-induced periodic surface structures (LIPSS) are studied on germanium surface in air by the femtosecond pulsed laser with repetition frequency of 76 MHz and wavelength λ of 800 nm. Three types of LIPSS were found and they are low-spatial-frequency LIPSS (LSFL), high-spatial-frequency LIPSS (HSFL), and LSFL superimposed with HSFL. The period ΛLSFL of LSFL shrinks quickly from approximately 650 nm to 400 nm (∼λ/2) when lowering the scanning speed. Comparatively, the period ΛHSFL of HSFL keeps almost constant between 90 and 100 nm (∼λ/8) when the scanning speed and the laser pulse energy vary. LSFL and HSFL coexist when the laser pulse energy is around 3.3 nJ/pulse and the scanning speed ranges between 3 and 8 mm/s. The surface plasmon polariton waves make a contribution to the formation of LIPSS and the fourth harmonic generation (FHG) might be involved in the formation of HSFL.

  13. Differentiating youth who are bullied from other victims of peer-aggression: the importance of differential power and repetition.

    Science.gov (United States)

    Ybarra, Michele L; Espelage, Dorothy L; Mitchell, Kimberly J

    2014-08-01

    To examine whether (1) among youth who report being bullied, differential power and repetition are useful in identifying youth who are more or less affected by the victimization experience and (2) bullying and more generalized peer aggression are distinct or overlapping constructs. Data for the Teen Health and Technology study were collected online between August 2010 and January 2011 from 3,989 13- to 18-year-olds. Data from the Growing up with Media study (Wave 3) were collected online in 2008 from 1,157 12- to 17-year-olds. In the Teen Health and Technology study, youth who reported neither differential power nor repetition had the lowest rates of interference with daily functioning. Youth who reported either differential power or repetition had higher rates, but the highest rates of interference with daily functioning were observed among youth who reported both differential power and repetition. In the Growing up with Media study, youth were victims of online generalized peer aggression (30%) or both online generalized peer aggression and cyberbullying (16%) but rarely cyberbullying alone (1%). Both differential power and repetition are key in identifying youth who are bullied and at particular risk for concurrent psychosocial challenge. Each feature needs to be measured directly. Generalized peer aggression appears to be a broader form of violence compared with bullying. It needs to be recognized that youth who are victimized but do not meet the criteria of bullying have elevated rates of problems. They are an important, albeit nonbullied, group of victimized youth to be included in research. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  14. Grade Repetition and Primary School Dropout in Uganda

    Science.gov (United States)

    Kabay, Sarah

    2016-01-01

    Research on education in low-income countries rarely focuses on grade repetition. When addressed, repetition is typically presented along with early school dropout as the "wasting" of educational resources. Simplifying grade repetition in this way often fails to recognize significant methodological concerns and also overlooks the unique…

  15. Analogous selection processes in declarative and procedural working memory: N-2 list-repetition and task-repetition costs.

    Science.gov (United States)

    Gade, Miriam; Souza, Alessandra S; Druey, Michel D; Oberauer, Klaus

    2017-01-01

    Working memory (WM) holds and manipulates representations for ongoing cognition. Oberauer (Psychology of Learning and Motivation, 51, 45-100, 2009) distinguishes between two analogous WM sub-systems: a declarative WM which handles the objects of thought, and a procedural WM which handles the representations of (cognitive) actions. Here, we assessed whether analogous effects are observed when participants switch between memory sets (declarative representations) and when they switch between task sets (procedural representations). One mechanism assumed to facilitate switching in procedural WM is the inhibition of previously used, but currently irrelevant task sets, as indexed by n-2 task-repetition costs (Mayr & Keele, Journal of Experimental Psychology: General, 129(1), 4-26, 2000). In this study we tested for an analogous effect in declarative WM. We assessed the evidence for n-2 list-repetition costs across eight experiments in which participants switched between memory lists to perform speeded classifications, mental arithmetic, or a local recognition test. N-2 list-repetition costs were obtained consistently in conditions assumed to increase interference between memory lists, and when lists formed chunks in long-term memory. Further analyses across experiments revealed a substantial contribution of episodic memory to n-2 list-repetition costs, thereby questioning the interpretation of n-2 repetition costs as reflecting inhibition. We reanalyzed the data of eight task-switching experiments, and observed that episodic memory also contributes to n-2 task-repetition costs. Taken together, these results show analogous processing principles in declarative and procedural WM, and question the relevance of inhibitory processes for efficient switching between mental sets.

  16. The Golden Ratio of Gait Harmony: Repetitive Proportions of Repetitive Gait Phases

    Directory of Open Access Journals (Sweden)

    Marco Iosa

    2013-01-01

    Full Text Available In nature, many physical and biological systems have structures showing harmonic properties. Some of them were found related to the irrational number known as the golden ratio that has important symmetric and harmonic properties. In this study, the spatiotemporal gait parameters of 25 healthy subjects were analyzed using a stereophotogrammetric system with 25 retroreflective markers located on their skin. The proportions of gait phases were compared with , the value of which is about 1.6180. The ratio between the entire gait cycle and stance phase resulted in 1.620 ± 0.058, that between stance and the swing phase was 1.629 ± 0.173, and that between swing and the double support phase was 1.684 ± 0.357. All these ratios did not differ significantly from each other (, , repeated measure analysis of variance or from (, resp., t-tests. The repetitive gait phases of physiological walking were found in turn in repetitive proportions with each other, revealing an intrinsic harmonic structure. Harmony could be the key for facilitating the control of repetitive walking. Harmony is a powerful unifying factor between seemingly disparate fields of nature, including human gait.

  17. Effect of loading on unintentional lifting velocity declines during single sets of repetitions to failure during upper and lower extremity muscle actions.

    Science.gov (United States)

    Izquierdo, M; González-Badillo, J J; Häkkinen, K; Ibáñez, J; Kraemer, W J; Altadill, A; Eslava, J; Gorostiaga, E M

    2006-09-01

    The purpose of this study was to examine the effect of different loads on repetition speed during single sets of repetitions to failure in bench press and parallel squat. Thirty-six physical active men performed 1-repetition maximum in a bench press (1 RM (BP)) and half squat position (1 RM (HS)), and performed maximal power-output continuous repetition sets randomly every 10 days until failure with a submaximal load (60 %, 65 %, 70 %, and 75 % of 1RM, respectively) during bench press and parallel squat. Average velocity of each repetition was recorded by linking a rotary encoder to the end part of the bar. The values of 1 RM (BP) and 1 RM (HS) were 91 +/- 17 and 200 +/- 20 kg, respectively. The number of repetitions performed for a given percentage of 1RM was significantly higher (p bench press performance. Average repetition velocity decreased at a greater rate in bench press than in parallel squat. The significant reductions observed in the average repetition velocity (expressed as a percentage of the average velocity achieved during the initial repetition) were observed at higher percentage of the total number of repetitions performed in parallel squat (48 - 69 %) than in bench press (34 - 40 %) actions. The major finding in this study was that, for a given muscle action (bench press or parallel squat), the pattern of reduction in the relative average velocity achieved during each repetition and the relative number of repetitions performed was the same for all percentages of 1RM tested. However, relative average velocity decreased at a greater rate in bench press than in parallel squat performance. This would indicate that in bench press the significant reductions observed in the average repetition velocity occurred when the number of repetitions was over one third (34 %) of the total number of repetitions performed, whereas in parallel squat it was nearly one half (48 %). Conceptually, this would indicate that for a given exercise (bench press or squat) and

  18. Tunable, high-repetition-rate, dual-signal-wavelength femtosecond optical parametric oscillator based on BiB3O6

    Science.gov (United States)

    Meng, Xianghao; Wang, Zhaohua; Tian, Wenlong; Fang, Shaobo; Wei, Zhiyi

    2018-01-01

    We have demonstrated a high-repetition-rate tunable femtosecond dual-signal-wavelength optical parametric oscillator (OPO) based on BiB3O6 (BiBO) crystal, synchronously pumped by a frequency-doubled mode-locked Yb:KGW laser. The cavity is simple since no dispersion compensators are used in the cavity. The wavelength range of dual-signal is widely tunable from 710 to 1000 nm. Tuning is accomplished by rotating phase-matching angle of BiBO, and optimizing cavity length and output coupler. Using a 3.75 W pump laser, the maximum average dual-signal output power is 760 mW at 707 and 750 nm, leading to a conversion efficiency of 20.3% not taking into account the idler power. Our experimental results show a non-critical phase-matching configuration pumped by a high peak power laser source. The operation of the dual-signal benefits from the balance of phase matching and group velocity mismatching between the two signals.

  19. 500 MW peak power degenerated optical parametric amplifier delivering 52 fs pulses at 97 kHz repetition rate.

    Science.gov (United States)

    Rothhardt, J; Hädrich, S; Röser, F; Limpert, J; Tünnermann, A

    2008-06-09

    We present a high peak power degenerated parametric amplifier operating at 1030 nm and 97 kHz repetition rate. Pulses of a state-of-the art fiber chirped-pulse amplification (FCPA) system with 840 fs pulse duration and 410 microJ pulse energy are used as pump and seed source for a two stage optical parametric amplifier. Additional spectral broadening of the seed signal in a photonic crystal fiber creates enough bandwidth for ultrashort pulse generation. Subsequent amplification of the broadband seed signal in two 1 mm BBO crystals results in 41 microJ output pulse energy. Compression in a SF 11 prism compressor yields 37 microJ pulses as short as 52 fs. Thus, pulse shortening of more than one order of magnitude is achieved. Further scaling in terms of average power and pulse energy seems possible and will be discussed, since both concepts involved, the fiber laser and the parametric amplifier have the reputation to be immune against thermo-optical effects.

  20. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  1. Shock-tube study of the decomposition of tetramethylsilane using gas chromatography and high-repetition-rate time-of-flight mass spectrometry.

    Science.gov (United States)

    Sela, P; Peukert, S; Herzler, J; Fikri, M; Schulz, C

    2018-04-25

    The decomposition of tetramethylsilane was studied in shock-tube experiments in a temperature range of 1270-1580 K and pressures ranging from 1.5 to 2.3 bar behind reflected shock waves combining gas chromatography/mass spectrometry (GC/MS) and high-repetition-rate time-of-flight mass spectrometry (HRR-TOF-MS). The main observed products were methane (CH4), ethylene (C2H4), ethane (C2H6), and acetylene (C2H2). In addition, the formation of a solid deposit was observed, which was identified to consist of silicon- and carbon-containing nanoparticles. A kinetics sub-mechanism with 13 silicon species and 20 silicon-containing reactions was developed. It was combined with the USC_MechII mechanism for hydrocarbons, which was able to simulate the experimental observations. The main decomposition channel of TMS is the Si-C bond scission forming methyl (CH3) and trimethylsilyl radicals (Si(CH3)3). The rate constant for TMS decomposition is represented by the Arrhenius expression ktotal[TMS → products] = 5.9 × 1012 exp(-267 kJ mol-1/RT) s-1.

  2. The Developmental Trajectory of Nonword Repetition

    Science.gov (United States)

    Chiat, Shula

    2006-01-01

    In line with the original presentation of nonword repetition as a measure of phonological short-term memory (Gathercole & Baddeley, 1989), the theoretical account Gathercole (2006) puts forward in her Keynote Article focuses on phonological storage as the key capacity common to nonword repetition and vocabulary acquisition. However, evidence that…

  3. Global Repetition Influences Contextual Cueing

    Science.gov (United States)

    Zang, Xuelian; Zinchenko, Artyom; Jia, Lina; Li, Hong

    2018-01-01

    Our visual system has a striking ability to improve visual search based on the learning of repeated ambient regularities, an effect named contextual cueing. Whereas most of the previous studies investigated contextual cueing effect with the same number of repeated and non-repeated search displays per block, the current study focused on whether a global repetition frequency formed by different presentation ratios between the repeated and non-repeated configurations influence contextual cueing effect. Specifically, the number of repeated and non-repeated displays presented in each block was manipulated: 12:12, 20:4, 4:20, and 4:4 in Experiments 1–4, respectively. The results revealed a significant contextual cueing effect when the global repetition frequency is high (≥1:1 ratio) in Experiments 1, 2, and 4, given that processing of repeated displays was expedited relative to non-repeated displays. Nevertheless, the contextual cueing effect reduced to a non-significant level when the repetition frequency reduced to 4:20 in Experiment 3. These results suggested that the presentation frequency of repeated relative to the non-repeated displays could influence the strength of contextual cueing. In other words, global repetition statistics could be a crucial factor to mediate contextual cueing effect. PMID:29636716

  4. Imbalance between abstract and concrete repetitive thinking modes in schizophrenia.

    Science.gov (United States)

    Maurage, Pierre; Philippot, Pierre; Grynberg, Delphine; Leleux, Dominique; Delatte, Benoît; Mangelinckx, Camille; Belge, Jan-Baptist; Constant, Eric

    2017-10-01

    Repetitive thoughts can be divided in two modes: abstract/analytic (decontextualized and dysfunctional) and concrete/experiential (problem-focused and adaptive). They constitute a transdiagnostic process involved in many psychopathological states but have received little attention in schizophrenia, as earlier studies only indexed increased ruminations (related to dysfunctional repetitive thoughts) without jointly exploring both modes. This study explored the two repetitive thinking modes, beyond ruminations, to determine their imbalance in schizophrenia. Thirty stabilized patients with schizophrenia and 30 matched controls completed the Repetitive Response Scale and the Mini Cambridge-Exeter Repetitive Thought Scale, both measuring repetitive thinking modes. Complementary measures related to schizophrenic symptomatology, depression and anxiety were also conducted. Compared to controls, patients with schizophrenia presented an imbalance between repetitive thinking modes, with increased abstract/analytic and reduced concrete/experiential thoughts, even after controlling for comorbidities. Schizophrenia is associated with stronger dysfunctional repetitive thoughts (i.e. abstract thinking) and impaired ability to efficiently use repetitive thinking for current problem-solving (i.e. concrete thinking). This imbalance confirms the double-faced nature of repetitive thinking modes, whose influence on schizophrenia's symptomatology should be further investigated. The present results also claim for evaluating these processes in clinical settings and for rehabilitating the balance between opposite repetitive thinking modes. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Direct electron acceleration in plasma waveguides for compact high-repetition-rate x-ray sources

    International Nuclear Information System (INIS)

    Lin, M-W; Jovanovic, I

    2014-01-01

    Numerous applications in fundamental and applied research, security, and industry require robust, compact sources of x-rays, with a particular recent interest in monochromatic, spatially coherent, and ultrafast x-ray pulses in well-collimated beams. Such x-ray sources usually require production of high-quality electron beams from compact accelerators. Guiding a radially polarized laser pulse in a plasma waveguide has been proposed for realizing direct laser acceleration (DLA), where the electrons are accelerated by the axial electric field of a co-propagating laser pulse (Serafim et al 2000 IEEE Trans. Plasma Sci. 28 1190). A moderate laser peak power is required for DLA when compared to laser wakefield acceleration, thus offering the prospect for high repetition rate operation. By using a density-modulated plasma waveguide for DLA, the acceleration distance can be extended with pulse guiding, while the density-modulation with proper axial structure can realize the quasi-phase matching between the laser pulses and electrons for a net gain accumulation (York et al 2008 Phys. Rev. Lett. 100 195001; York et al 2008 J. Opt. Soc. Am. B 25 B137; Palastro et al 2008 Phys. Rev. E 77 036405). We describe the development and application of a test particle model and particle-in-cell model for DLA. Experimental setups designed for fabrication of optically tailored plasma waveguides via the ignitor-heater scheme, and for generation and characterization of radially polarized short pulses used to drive DLA, are presented. (paper)

  6. Genomic Organization and Physical Mapping of Tandemly Arranged Repetitive DNAs in Sterlet (Acipenser ruthenus).

    Science.gov (United States)

    Biltueva, Larisa S; Prokopov, Dimitry Y; Makunin, Alexey I; Komissarov, Alexey S; Kudryavtseva, Anna V; Lemskaya, Natalya A; Vorobieva, Nadezhda V; Serdyukova, Natalia A; Romanenko, Svetlana A; Gladkikh, Olga L; Graphodatsky, Alexander S; Trifonov, Vladimir A

    2017-01-01

    Acipenseriformes represent a phylogenetically basal clade of ray-finned fish characterized by unusual genomic traits, including paleopolyploid states of extant genomes with high chromosome numbers and slow rates of molecular evolution. Despite a high interest in this fish group, only a limited number of studies have been accomplished on the isolation and characterization of repetitive DNA, karyotype standardization is not yet complete, and sex chromosomes are still to be identified. Here, we applied next-generation sequencing and cluster analysis to characterize major fractions of sterlet (Acipenser ruthenus) repetitive DNA. Using FISH, we mapped 16 tandemly arranged sequences on sterlet chromosomes and found them to be unevenly distributed in the genome with a tendency to cluster in particular regions. Some of the satellite DNAs might be used as specific markers to identify individual chromosomes and their paralogs, resulting in the unequivocal identification of at least 18 chromosome pairs. Our results provide an insight into the characteristic genomic distribution of the most common sterlet repetitive sequences. Biased accumulation of repetitive DNAs in particular chromosomes makes them especially interesting for further search for cryptic sex chromosomes. Future studies of these sequences in other acipenserid species will provide new perspectives regarding the evolution of repetitive DNA within the genomes of this fish order. © 2017 S. Karger AG, Basel.

  7. Repetitive thinking, executive functioning, and depressive mood in the elderly.

    Science.gov (United States)

    Philippot, Pierre; Agrigoroaei, Stefan

    2017-11-01

    Previous findings and the depressive-executive dysfunction hypothesis suggest that the established association between executive functioning and depression is accounted for by repetitive thinking. Investigating the association between executive functioning, repetitive thinking, and depressive mood, the present study empirically tested this mediational model in a sample of older adults, while focusing on both concrete and abstract repetitive thinking. This latter distinction is important given the potential protective role of concrete repetitive thinking, in contrast to the depletive effect of abstract repetitive thinking. A sample of 43 elderly volunteers, between 75 and 95 years of age, completed tests of executive functioning (the Stroop test, the Trail Making test, and the Fluency test), and questionnaires of repetitive thinking and depression. Positive correlations were observed between abstract repetitive thinking and depressive mood, and between concrete repetitive thinking and executive functioning; a negative correlation was observed between depressive mood and executive functioning. Further, mediational analysis evidenced that the relation between executive functioning and depressive mood was mediated by abstract repetitive thinking. The present data provide, for the first time, empirical support to the depressive-executive dysfunction hypothesis: the lack of executive resources would favor a mode of abstract repetitive thinking, which in turn would deplete mood. It suggests that clinical intervention targeting depression in the elderly should take into consideration repetitive thinking modes and the executive resources needed to disengage from rumination.

  8. Effects of message repetition and negativity on credibility judgments and political attitudes

    NARCIS (Netherlands)

    Ernst, N.; Kühne, R.; Wirth, W.

    2017-01-01

    Research on the truth effect has demonstrated that statements are rated as more credible when they are repeatedly presented. However, current research indicates that there are limits to the truth effect and that too many repetitions can decrease message credibility. This study investigates whether

  9. GHz-rate optical parametric amplifier in hydrogenated amorphous silicon

    International Nuclear Information System (INIS)

    Wang, Ke-Yao; Foster, Amy C

    2015-01-01

    We demonstrate optical parametric amplification operating at GHz-rates at telecommunications wavelengths using a hydrogenated amorphous silicon waveguide through the nonlinear optical process of four-wave mixing. We investigate how the parametric amplification scales with repetition rate. The ability to achieve amplification at GHz-repetition rates shows hydrogenated amorphous silicon’s potential for telecommunication applications and a GHz-rate optical parametric oscillator. (paper)

  10. Generation of fast-rise time, repetitive, (sub) nanosecond, high-voltage pulses

    NARCIS (Netherlands)

    Huiskamp, T.; Pemen, A.J.M.

    2017-01-01

    In this contribution we present our fast-rise time nanosecond pulse generator, capable of generating up to 50 kV (positive and negative) rectangular pulses at a repetition rate of up to 1 kHz and with a rise time of less than 200 picoseconds. We focus on the general concepts involved in the design

  11. Directed PCR-free engineering of highly repetitive DNA sequences

    Directory of Open Access Journals (Sweden)

    Preissler Steffen

    2011-09-01

    Full Text Available Abstract Background Highly repetitive nucleotide sequences are commonly found in nature e.g. in telomeres, microsatellite DNA, polyadenine (poly(A tails of eukaryotic messenger RNA as well as in several inherited human disorders linked to trinucleotide repeat expansions in the genome. Therefore, studying repetitive sequences is of biological, biotechnological and medical relevance. However, cloning of such repetitive DNA sequences is challenging because specific PCR-based amplification is hampered by the lack of unique primer binding sites resulting in unspecific products. Results For the PCR-free generation of repetitive DNA sequences we used antiparallel oligonucleotides flanked by restriction sites of Type IIS endonucleases. The arrangement of recognition sites allowed for stepwise and seamless elongation of repetitive sequences. This facilitated the assembly of repetitive DNA segments and open reading frames encoding polypeptides with periodic amino acid sequences of any desired length. By this strategy we cloned a series of polyglutamine encoding sequences as well as highly repetitive polyadenine tracts. Such repetitive sequences can be used for diverse biotechnological applications. As an example, the polyglutamine sequences were expressed as His6-SUMO fusion proteins in Escherichia coli cells to study their aggregation behavior in vitro. The His6-SUMO moiety enabled affinity purification of the polyglutamine proteins, increased their solubility, and allowed controlled induction of the aggregation process. We successfully purified the fusions proteins and provide an example for their applicability in filter retardation assays. Conclusion Our seamless cloning strategy is PCR-free and allows the directed and efficient generation of highly repetitive DNA sequences of defined lengths by simple standard cloning procedures.

  12. Lingual Kinematics during Rapid Syllable Repetition in Parkinson's Disease

    Science.gov (United States)

    Wong, Min Ney; Murdoch, Bruce E.; Whelan, Brooke-Mai

    2012-01-01

    Background: Rapid syllable repetition tasks are commonly used in the assessment of motor speech disorders. However, little is known about the articulatory kinematics during rapid syllable repetition in individuals with Parkinson's disease (PD). Aims: To investigate and compare lingual kinematics during rapid syllable repetition in dysarthric…

  13. Negative effects of item repetition on source memory.

    Science.gov (United States)

    Kim, Kyungmi; Yi, Do-Joon; Raye, Carol L; Johnson, Marcia K

    2012-08-01

    In the present study, we explored how item repetition affects source memory for new item-feature associations (picture-location or picture-color). We presented line drawings varying numbers of times in Phase 1. In Phase 2, each drawing was presented once with a critical new feature. In Phase 3, we tested memory for the new source feature of each item from Phase 2. Experiments 1 and 2 demonstrated and replicated the negative effects of item repetition on incidental source memory. Prior item repetition also had a negative effect on source memory when different source dimensions were used in Phases 1 and 2 (Experiment 3) and when participants were explicitly instructed to learn source information in Phase 2 (Experiments 4 and 5). Importantly, when the order between Phases 1 and 2 was reversed, such that item repetition occurred after the encoding of critical item-source combinations, item repetition no longer affected source memory (Experiment 6). Overall, our findings did not support predictions based on item predifferentiation, within-dimension source interference, or general interference from multiple traces of an item. Rather, the findings were consistent with the idea that prior item repetition reduces attention to subsequent presentations of the item, decreasing the likelihood that critical item-source associations will be encoded.

  14. Design and development of repetitive capacitor charging power supply based on series-parallel resonant converter topology.

    Science.gov (United States)

    Patel, Ankur; Nagesh, K V; Kolge, Tanmay; Chakravarthy, D P

    2011-04-01

    LCL resonant converter based repetitive capacitor charging power supply (CCPS) is designed and developed in the division. The LCL converter acts as a constant current source when switching frequency is equal to the resonant frequency. When both resonant inductors' values of LCL converter are same, it results in inherent zero current switching (ZCS) in switches. In this paper, ac analysis with fundamental frequency approximation of LCL resonant tank circuit, frequency dependent of current gain converter followed by design, development, simulation, and practical result is described. Effect of change in switching frequency and resonant frequency and change in resonant inductors ratio on CCPS will be discussed. An efficient CCPS of average output power of 1.2 kJ/s, output voltage 3 kV, and 300 Hz repetition rate is developed in the division. The performance of this CCPS has been evaluated in the laboratory by charging several values of load capacitance at various repetition rates. These results indicate that this design is very feasible for use in capacitor-charging applications. © 2011 American Institute of Physics

  15. Selective attention modulates neural substrates of repetition priming and "implicit" visual memory: suppressions and enhancements revealed by FMRI.

    Science.gov (United States)

    Vuilleumier, Patrik; Schwartz, Sophie; Duhoux, Stéphanie; Dolan, Raymond J; Driver, Jon

    2005-08-01

    Attention can enhance processing for relevant information and suppress this for ignored stimuli. However, some residual processing may still arise without attention. Here we presented overlapping outline objects at study, with subjects attending to those in one color but not the other. Attended objects were subsequently recognized on a surprise memory test, whereas there was complete amnesia for ignored items on such direct explicit testing; yet reliable behavioral priming effects were found on indirect testing. Event-related fMRI examined neural responses to previously attended or ignored objects, now shown alone in the same or mirror-reversed orientation as before, intermixed with new items. Repetition-related decreases in fMRI responses for objects previously attended and repeated in the same orientation were found in the right posterior fusiform, lateral occipital, and left inferior frontal cortex. More anterior fusiform regions also showed some repetition decreases for ignored objects, irrespective of orientation. View-specific repetition decreases were found in the striate cortex, particularly for previously attended items. In addition, previously ignored objects produced some fMRI response increases in the bilateral lingual gyri, relative to new objects. Selective attention at exposure can thus produce several distinct long-term effects on processing of stimuli repeated later, with neural response suppression stronger for previously attended objects, and some response enhancement for previously ignored objects, with these effects arising in different brain areas. Although repetition decreases may relate to positive priming phenomena, the repetition increases for ignored objects shown here for the first time might relate to processes that can produce "negative priming" in some behavioral studies. These results reveal quantitative and qualitative differences between neural substrates of long-term repetition effects for attended versus unattended objects.

  16. Pre-Lexical Disorders in Repetition Conduction Aphasia

    Science.gov (United States)

    Sidiropoulos, Kyriakos; de Bleser, Ria; Ackermann, Hermann; Preilowski, Bruno

    2008-01-01

    At the level of clinical speech/language evaluation, the repetition type of conduction aphasia is characterized by repetition difficulties concomitant with reduced short-term memory capacities, in the presence of fluent spontaneous speech as well as unimpaired naming and reading abilities. It is still unsettled which dysfunctions of the…

  17. Evidence for the involvement of a nonlexical route in the repetition of familiar words: A comparison of single and dual route models of auditory repetition.

    Science.gov (United States)

    Hanley, J Richard; Dell, Gary S; Kay, Janice; Baron, Rachel

    2004-03-01

    In this paper, we attempt to simulate the picture naming and auditory repetition performance of two patients reported by Hanley, Kay, and Edwards (2002), who were matched for picture naming score but who differed significantly in their ability to repeat familiar words. In Experiment 1, we demonstrate that the model of naming and repetition put forward by Foygel and Dell (2000) is better able to accommodate this pattern of performance than the model put forward by Dell, Schwartz, Martin, Saffran, and Gagnon (1997). Nevertheless, Foygel and Dell's model underpredicted the repetition performance of both patients. In Experiment 2, we attempt to simulate their performance using a new dual route model of repetition in which Foygel and Dell's model is augmented by an additional nonlexical repetition pathway. The new model provided a more accurate fit to the real-word repetition performance of both patients. It is argued that the results provide support for dual route models of auditory repetition.

  18. High-repetition intra-cavity source of Compton radiation

    International Nuclear Information System (INIS)

    Pogorelsky, I; Polyanskiy, M; Agustsson, R; Campese, T; Murokh, A; Ovodenko, A; Shaftan, T

    2014-01-01

    We report our progress in developing a high-power Compton source for a diversity of applications ranging from university-scale compact x-ray light sources and metrology tools for EUV lithography, to high-brilliance gamma-sources for nuclear analysis. Our conceptual approach lies in multiplying the source’s repetition rate and increasing its average brightness by placing the Compton interaction point inside the optical cavity of an active laser. We discuss considerations in its design, our simulations, and tests of the laser’s cavity that confirm the feasibility of the proposed concept. (paper)

  19. Optimizing strategy software for repetitive construction projects within multi-mode resources

    Directory of Open Access Journals (Sweden)

    Remon Fayek Aziz

    2013-09-01

    Full Text Available Estimating tender data for specific project is the most essential part in construction areas as of contractor’s view such as: proposed project duration with corresponding gross value and cash flows. This paper focuses on how to calculate tender data using Optimizing Strategy Software (OSS for repetitive construction projects with identical activity’s duration in case of single number of crew such as: project duration, project/bid price, project maximum working capital, and project net present value of the studied project. A simplified multi-objective optimization software (OSS will be presented that creates best tender data to contractor compared with more feasible options generated from multi-mode resources in a given project. OSS is intended to give more scenarios which provide practical support for typical construction contractors who need to optimize resource utilization in order to minimize project duration, project/bid price, and project maximum working capital while maximizing its net present value simultaneously. OSS is designed by java programing code system to provide a number of new and unique capabilities, including: (1 Ranking the obtained optimal plans according to a set of planner specified weights representing the relative importance of duration, price, maximum working capital and net present value in the analyzed project; (2 Visualizing and viewing the generated optimal trade-off; and (3 Providing seamless integration with available project management calculations. In order to provide the aforementioned capabilities of OSS, the system is implemented and developed in four main modules: (1 A user interface module; (2 A database module; (3 A running module; (4 A connecting module. At the end of the paper, an illustrative example will be presented to demonstrate and verify the applications of the proposed software (OSS to an optimization expressway of repetitive construction project.

  20. Muscle activation strategies during strength training with heavy loading versus repetitions to failure

    DEFF Research Database (Denmark)

    Sundstrup, Emil; Jakobsen, Markus D; Andersen, Christoffer H

    2012-01-01

    . Electromyographic (EMG) amplitude and median power frequency (MPF) of specific shoulder and neck muscles was analysed and the Borg CR10 scale was used to rate perceived loading immediately after each set of exercise. During the failure set normalized EMG was significantly lower during the first repetition...

  1. Relationship between the number of repetitions and selected percentages of one repetition maximum in free weight exercises in trained and untrained men.

    Science.gov (United States)

    Shimano, Tomoko; Kraemer, William J; Spiering, Barry A; Volek, Jeff S; Hatfield, Disa L; Silvestre, Ricardo; Vingren, Jakob L; Fragala, Maren S; Maresh, Carl M; Fleck, Steven J; Newton, Robert U; Spreuwenberg, Luuk P B; Häkkinen, Keijo

    2006-11-01

    Resistance exercise intensity is commonly prescribed as a percent of 1 repetition maximum (1RM). However, the relationship between percent 1RM and the number of repetitions allowed remains poorly studied, especially using free weight exercises. The purpose of this study was to determine the maximal number of repetitions that trained (T) and untrained (UT) men can perform during free weight exercises at various percentages of 1RM. Eight T and 8 UT men were tested for 1RM strength. Then, subjects performed 1 set to failure at 60, 80, and 90% of 1RM in the back squat, bench press, and arm curl in a randomized, balanced design. There was a significant (p squat than the bench press or arm curl at 60% 1RM for T and UT. At 80 and 90% 1RM, there were significant differences between the back squat and other exercises; however, differences were much less pronounced. No differences in number of repetitions performed at a given exercise intensity were noted between T and UT (except during bench press at 90% 1RM). In conclusion, the number of repetitions performed at a given percent of 1RM is influenced by the amount of muscle mass used during the exercise, as more repetitions can be performed during the back squat than either the bench press or arm curl. Training status of the individual has a minimal impact on the number of repetitions performed at relative exercise intensity.

  2. Changes in patellofemoral pain resulting from repetitive impact landings are associated with the magnitude and rate of patellofemoral joint loading.

    Science.gov (United States)

    Atkins, Lee T; James, C Roger; Yang, Hyung Suk; Sizer, Phillip S; Brismée, Jean-Michel; Sawyer, Steven F; Powers, Christopher M

    2018-03-01

    Although a relationship between elevated patellofemoral forces and pain has been proposed, it is unknown which joint loading variable (magnitude, rate) is best associated with pain changes. The purpose of this study was to examine associations among patellofemoral joint loading variables and changes in patellofemoral pain across repeated single limb landings. Thirty-one females (age: 23.5(2.8) year; height: 166.8(5.8) cm; mass: 59.6(8.1) kg) with PFP performed 5 landing trials from 0.25 m. The dependent variable was rate of change in pain obtained from self-reported pain scores following each trial. Independent variables included 5-trial averages of peak, time-integral, and average and maximum development rates of the patellofemoral joint reaction force obtained using a previously described model. Pearson correlation coefficients were calculated to evaluate individual associations between rate of change in pain and each independent variable (α = 0.05). Stepwise linear multiple regression (α enter  = 0.05; α exit  = 0.10) was used to identify the best predictor of rate of change in pain. Subjects reported an average increase of 0.38 pain points with each landing trial. Although, rate of change in pain was positively correlated with peak force (r = 0.44, p = 0.01), and average (r = 0.41, p = 0.02) and maximum force development rates (r = 0.39, p = 0.03), only the peak force entered the predictive model explaining 19% of variance in rate of change in pain (r 2  = 0.19, p = 0.01). Peak patellofemoral joint reaction force was the best predictor of the rate of change in pain following repetitive singe limb landings. The current study supports the theory that patellofemoral joint loading contributes to changes in patellofemoral pain. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Understanding work related musculoskeletal pain: does repetitive work cause stress symptoms?

    DEFF Research Database (Denmark)

    Bonde, J. P.; Mikkelsen, S.; Andersen, JH

    2005-01-01

    for development of regional pain in repetitive work, stress symptoms would likely be on the causal path. AIMS: To examine whether objective measures of repetitive monotonous work are related to occurrence and development of stress symptoms. METHODS: In 1994-95, 2033 unskilled workers with continuous repetitive...... Profile Inventory. RESULTS: Repetitive work, task cycle time, and quantified measures of repetitive upper extremity movements including force requirements were not related to occurrence of stress symptoms at baseline or development of stress symptoms during three years of follow up. CONCLUSIONS......: The findings do not indicate that repetitive work is associated with stress symptoms, but small effects cannot be ruled out. Thus the results question the importance of mental stress mechanisms in the causation of regional pain related to repetitive work. However, the findings should be interpreted...

  4. Inverted U-shaped model: How frequent repetition affects perceived risk

    OpenAIRE

    Xi Lu; Xiaofei Xie; Lu Liu

    2015-01-01

    We asked how repeated media reports on technological hazards influence an individual's risk perception. We looked for two contradictory effects, an increasing effect of repetition on perceived risk with the first few repetitions and a decreasing effect with later repetitions, leading to the inverted U-shaped pattern. In an experiment, we demonstrated the inverted U-shaped relationship between the repetition and perceived risk in the context of food risk. The finding broaden...

  5. Measurement of acoustic velocity components in a turbulent flow using LDV and high-repetition rate PIV

    Science.gov (United States)

    Léon, Olivier; Piot, Estelle; Sebbane, Delphine; Simon, Frank

    2017-06-01

    The present study provides theoretical details and experimental validation results to the approach proposed by Minotti et al. (Aerosp Sci Technol 12(5):398-407, 2008) for measuring amplitudes and phases of acoustic velocity components (AVC) that are waveform parameters of each component of velocity induced by an acoustic wave, in fully turbulent duct flows carrying multi-tone acoustic waves. Theoretical results support that the turbulence rejection method proposed, based on the estimation of cross power spectra between velocity measurements and a reference signal such as a wall pressure measurement, provides asymptotically efficient estimators with respect to the number of samples. Furthermore, it is shown that the estimator uncertainties can be simply estimated, accounting for the characteristics of the measured flow turbulence spectra. Two laser-based measurement campaigns were conducted in order to validate the acoustic velocity estimation approach and the uncertainty estimates derived. While in previous studies estimates were obtained using laser Doppler velocimetry (LDV), it is demonstrated that high-repetition rate particle image velocimetry (PIV) can also be successfully employed. The two measurement techniques provide very similar acoustic velocity amplitude and phase estimates for the cases investigated, that are of practical interest for acoustic liner studies. In a broader sense, this approach may be beneficial for non-intrusive sound emission studies in wind tunnel testings.

  6. Central Hemodynamics Measured During 5 Repetition Maximum Free Weight Resistance Exercise.

    Science.gov (United States)

    Howard, Jonathan S; McLester, Cherilyn N; Evans, Thomas W; McLester, John R; Calloway, Jimmy P

    2018-01-01

    The PhysioFlow™ is a piece of equipment that uses bioimpedance cardiography to measure central hemodynamics. The purpose of this research was to explore the novel approach of monitoring central hemodynamics during free weight resistance exercise using bioimpedance cardiography throughout a 5 repetition maximum (5RM). Thirty participants ranging from beginner to advanced lifters (16 males and 14 females) completed a 5RM for back squat, seated push press, and bicep curl while connected to the PhysioFlow™ to assess the response of heart rate (HR), stroke volume (SV), cardiac output (Q), and ejection fraction (EF). Participants were cued for form and to breathe normally throughout the lifts. The PhysioFlow™ detected an increase in HR and Q for all lifts between rest and each repetition ( p 0.05) and no changes in EF or SV were detected when all repetitions were compared to each other for all lifts ( p > 0.05). In conclusion, the PhysioFlow™ was able to detect changes in HR and Q during dynamic free weight resistance exercise. This novel approach may provide a mechanism for monitoring central hemodynamics during free weight resistance training. However, more research needs to be conducted as the exercise protocol for this investigation did not allow for a comparison to a reference method.

  7. Translation of Syntactic Repetitions as Formal-Aesthetic Marker in Das Brot

    Directory of Open Access Journals (Sweden)

    Rosyidah

    2017-03-01

    Full Text Available Translating repetition as a formal-aesthetic marker in a literary text is a hard task and challenge for translators. The topic of this study is translation of syntactic repetition as formal-aesthetic marker in literary text. The problems examined include: (1 the syntactic repetitions in the source text and (2 the strategies to translate these repetitions carried out by the students. This is a case study with a qualitative approach which is aimed to describe the syntactic repetitions as formal aesthetic markers in the German short story Das Brot written by Wolfgang Borchert and to explain the strategies used by Indonesian students to translate the syntactic repetitions. The research data are repetitive sentences gained from the German short story and from the translated versions done by 60 students. The analysis was carried out interactively and sociosemiotically. The results show that there were repetitions at the sentence level including sentence parts, sentences and content repetition in the source text. The strategies used by the students to translate the repetitions of sentence part and sentence were exact preservation and modified preservation with reduction, implicitation and addition of extra words, avoidance with deletion, explicitation, implicitation, nominalization, and synonymy. In the meantime, content repetitions were translated using the strategy of exact preservation and preservation with modification by adding extra words and using role-based terms of address. Thus, the results lead to two new variations of modified preservation, namely preservation by adding extra words and by changing addressing terms and one new variation of avoidance that is explicitation.

  8. [Infiltration characteristics of soil water on loess slope land under intermittent and repetitive rainfall conditions].

    Science.gov (United States)

    Li, Yi; Shao, Ming-An

    2008-07-01

    Based on the experiments of controlled intermittent and repetitive rainfall on slope land, the infiltration and distribution characteristics of soil water on loess slope land were studied. The results showed that under the condition of intermittent rainfall, the cumulative runoff during two rainfall events increased linearly with time, and the wetting front also increased with time. In the interval of the two rainfall events, the wetting front increased slowly, and the infiltration rate was smaller on steeper slope than on flat surface. During the second rainfall event, there was an obvious decreasing trend of infiltration rate with time. The cumulative infiltration on 15 degrees slope land was larger than that of 25 degrees slope land, being 178 mm and 88 mm, respectively. Under the condition of repetitive rainfall, the initial infiltration rate during each rainfall event was relatively large, and during the first rainfall, both the infiltration rate and the cumulative infiltration at various stages were larger than those during the other three rainfall events. However, after the first rainfall, there were no obvious differences in the infiltration rate among the next three rainfall events. The more the rainfall event, the deeper the wetting front advanced.

  9. Vitamin B-12 Deficiency in Children Is Associated with Grade Repetition and School Absenteeism, Independent of Folate, Iron, Zinc, or Vitamin A Status Biomarkers.

    Science.gov (United States)

    Duong, Minh-Cam; Mora-Plazas, Mercedes; Marín, Constanza; Villamor, Eduardo

    2015-07-01

    Micronutrients are essential to neurocognitive development; yet their role in educational outcomes is unclear. We examined the associations of micronutrient status biomarkers with the risk of grade repetition and rates of school absenteeism in a cohort of school children. We recruited 3156 children aged 5-12 y from public schools in Bogota, Colombia. Circulating ferritin, hemoglobin, zinc, vitamin A, and vitamin B-12; erythrocyte folate; and mean corpuscular volume (MCV) were measured in blood samples obtained at the beginning of the year. Absenteeism was recorded weekly during the school year, and grade repetition was determined the next year. Risk ratios for grade repetition and rate ratios for absenteeism were estimated by categories of micronutrient status indicators with use of Poisson regression, adjusting for potential confounders. The risk of grade repetition was 4.9%, and the absenteeism rate was 3.8 d per child-year of observation. Vitamin B-12 deficiency (educational outcomes and neurocognitive development of school children need to be determined in intervention studies. © 2015 American Society for Nutrition.

  10. High power all-solid-state fourth harmonic generation of 266 nm at the pulse repetition rate of 100 kHz

    International Nuclear Information System (INIS)

    Liu, Q; Yan, X P; Fu, X; Gong, M; Wang, D S

    2009-01-01

    14.8 W UV laser at 266 nm was reported with the extra cavity frequency quartered configuration. The fundamental frequency IR source is a high-power high-beam-quality acoustic-optic Q-switched Nd:YVO 4 master-oscillator-power-amplifier laser. The type-I phase-matched LBO and type-I phase-matched BBO crystals were used as the extra-cavity frequency doubled and quartered crystal respectively. 14.8 W UV laser of 266 nm was obtained at the pulse repetition rate of 100 kHz with the conversion efficiency of 18.3% from green to UV, and the pulse duration of the UV laser was 10 ns corresponding to the pulse peak power of 14.8 kW. At 150 kHz, 11.5 W power output was obtained. The highest peak power of 21 kW was also achieved at 80 kHz with the average output power of 14.5 W

  11. Effect of pulse repetition rate and number of pulses in the analysis of polypropylene and high density polyethylene by nanosecond infrared laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Leme, Flavio O. [Laboratorio de Quimica Analitica ' Henrique Bergamin Filho' , Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Av. Centenario 303, 13416-000 Piracicaba, SP (Brazil); Godoi, Quienly [Laboratorio de Quimica Analitica ' Henrique Bergamin Filho' , Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Av. Centenario 303, 13416-000 Piracicaba, SP (Brazil); Departamento de Quimica, Universidade Federal de Sao Carlos, Rod. Washington Luis, km 235, 13565-905 Sao Carlos, SP (Brazil); Kiyataka, Paulo H.M. [Centro de Tecnologia de Embalagens, Instituto de Tecnologia de Alimentos, Av. Brasil 2880, 13070-178 Campinas, SP (Brazil); Santos, Dario [Departamento de Ciencias Exatas e da Terra, Universidade Federal de Sao Paulo, Rua Prof. Artur Riedel 275, 09972-270 Diadema, SP (Brazil); Agnelli, Jose A.M. [Departamento de Engenharia de Materiais, Universidade Federal de Sao Carlos, Rod. Washington Luis, km 235, 13565-905 Sao Carlos, SP (Brazil); and others

    2012-02-01

    Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO{sub 4}. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm{sup -2}), 2 {mu}s delay time and 6 {mu}s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant.

  12. Thin liquid sheet target capabilities for ultra-intense laser acceleration of ions at a kHz repetition rate

    Science.gov (United States)

    Klim, Adam; Morrison, J.; Orban, C.; Chowdhury, E.; Frische, K.; Feister, S.; Roquemore, M.

    2017-10-01

    The success of laser-accelerated ion experiments depends crucially on a number of factors including how thin the targets can be created. We present experimental results demonstrating extremely thin (under 200 nm) glycol sheet targets that can be used for ultra-intense laser-accelerated ion experiments conducted at the Air Force Research Laboratory at Wright-Patterson Air Force Base. Importantly, these experiments operate at a kHz repetition rate and the recovery time of the liquid targets is fast enough to allow the laser to interact with a refreshed, thin target on every shot. These thin targets can be used to produce energetic electrons, light ions, and neutrons as well as x-rays, we present results from liquid glycol targets which are useful for proton acceleration experiments via the mechanism of Target Normal Sheath Acceleration (TNSA). In future work, we will create thin sheets from deuterated water in order to perform laser-accelerated deuteron experiments. This research was sponsored by the Quantum and Non-Equilibrium Processes Division of the AFOSR, under the management of Dr. Enrique Parra, and support from the DOD HPCMP Internship Program.

  13. [Repetitive phenomenona in the spontaneous speech of aphasic patients: perseveration, stereotypy, echolalia, automatism and recurring utterance].

    Science.gov (United States)

    Wallesch, C W; Brunner, R J; Seemüller, E

    1983-12-01

    Repetitive phenomena in spontaneous speech were investigated in 30 patients with chronic infarctions of the left hemisphere which included Broca's and/or Wernicke's area and/or the basal ganglia. Perseverations, stereotypies, and echolalias occurred with all types of brain lesions, automatisms and recurring utterances only with those patients, whose infarctions involved Wernicke's area and basal ganglia. These patients also showed more echolalic responses. The results are discussed in view of the role of the basal ganglia as motor program generators.

  14. Multivariate prediction of spontaneous repetitive responses in ventricular myocardium exposed in vitro to simulated ischemic conditions.

    Science.gov (United States)

    Schiariti, M; Puddu, P E; Rouet, R

    1994-06-01

    Guinea-pig ventricular myocardium was partly exposed to normal Tyrode's superfusion and partly to altered conditions (using modified Tyrode's solution) set to simulate acute myocardial ischemia (PO2 80 +/- 10 mmHg; no glucose; pH 7.00 +/- 0.05; K+ 12 mM). Using a double-chamber tissue bath and standard microelectrode technique, the occurrence of spontaneous repetitive responses was investigated during simulated ischemia (occlusion) and after reperfusing the previously ischemic superfused tissue with normal Tyrode's solution (reperfusion). In 62 experiments (42 animals) the effects of: (1) duration of simulated ischemia (1321 +/- 435 s), (2) stimulation rate (1002 +/- 549 ms) and (3) number of successive simulated ischemic periods (occlusions) (1.58 +/- 0.92) on: (1) resting membrane potential, (2) action potential amplitude, (3) duration of 50 and 90% action potentials and (4) maximal upstroke velocity of action potential were studied. All variables were considered as gradients (delta) between normal and ischemic tissue. Both during occlusion and upon reperfusion, spontaneous repetitive responses were coded as single, couplets, salvos (three to nine and > 10) or total spontaneous repetitive responses (coded present when at least one of the above-mentioned types was seen). The incidence of total spontaneous repetitive responses was 31% (19/62) on occlusion and 85% (53/62) upon reperfusion. Cox's models (forced and stepwise) were used to predict multivariately the occurrence of arrhythmic events considered as both total spontaneous repetitive responses and as separate entities. These models were applicable since continuous monitoring of the experiments enabled exact timing of spontaneous repetitive response onset during both occlusion and reperfusion. In predicting reperfusion spontaneous repetitive responses, total spontaneous repetitive responses and blocks observed during the occlusion period were also considered. Total occlusion spontaneous repetitive responses

  15. Understanding work related musculoskeletal pain: does repetitive work cause stress symptoms?

    Science.gov (United States)

    Bonde, J P; Mikkelsen, S; Andersen, J H; Fallentin, N; Baelum, J; Svendsen, S W; Thomsen, J F; Frost, P; Kaergaard, A

    2005-01-01

    Pain in the neck and upper extremity is reported with high frequency in repetitive work. Mechanical overload of soft tissues seems a plausible mechanism, but psychological factors have received considerable attention during the past decade. If psychological factors are important for development of regional pain in repetitive work, stress symptoms would likely be on the causal path. To examine whether objective measures of repetitive monotonous work are related to occurrence and development of stress symptoms. In 1994-95, 2033 unskilled workers with continuous repetitive work and 813 workers with varied work were enrolled. Measures of repetitiveness and force requirements were quantified using video observations to obtain individual exposure estimates. Stress symptoms were recorded at baseline and after approximately one, two, and three years by the Setterlind Stress Profile Inventory. Repetitive work, task cycle time, and quantified measures of repetitive upper extremity movements including force requirements were not related to occurrence of stress symptoms at baseline or development of stress symptoms during three years of follow up. The findings do not indicate that repetitive work is associated with stress symptoms, but small effects cannot be ruled out. Thus the results question the importance of mental stress mechanisms in the causation of regional pain related to repetitive work. However, the findings should be interpreted with caution because the stress inventory has not been validated against a gold standard.

  16. Fractional averaging of repetitive waveforms induced by self-imaging effects

    Science.gov (United States)

    Romero Cortés, Luis; Maram, Reza; Azaña, José

    2015-10-01

    We report the theoretical prediction and experimental observation of averaging of stochastic events with an equivalent result of calculating the arithmetic mean (or sum) of a rational number of realizations of the process under test, not necessarily limited to an integer record of realizations, as discrete statistical theory dictates. This concept is enabled by a passive amplification process, induced by self-imaging (Talbot) effects. In the specific implementation reported here, a combined spectral-temporal Talbot operation is shown to achieve undistorted, lossless repetition-rate division of a periodic train of noisy waveforms by a rational factor, leading to local amplification, and the associated averaging process, by the fractional rate-division factor.

  17. Consumer Neuroscience-Based Metrics Predict Recall, Liking and Viewing Rates in Online Advertising.

    Science.gov (United States)

    Guixeres, Jaime; Bigné, Enrique; Ausín Azofra, Jose M; Alcañiz Raya, Mariano; Colomer Granero, Adrián; Fuentes Hurtado, Félix; Naranjo Ornedo, Valery

    2017-01-01

    The purpose of the present study is to investigate whether the effectiveness of a new ad on digital channels (YouTube) can be predicted by using neural networks and neuroscience-based metrics (brain response, heart rate variability and eye tracking). Neurophysiological records from 35 participants were exposed to 8 relevant TV Super Bowl commercials. Correlations between neurophysiological-based metrics, ad recall, ad liking, the ACE metrix score and the number of views on YouTube during a year were investigated. Our findings suggest a significant correlation between neuroscience metrics and self-reported of ad effectiveness and the direct number of views on the YouTube channel. In addition, and using an artificial neural network based on neuroscience metrics, the model classifies (82.9% of average accuracy) and estimate the number of online views (mean error of 0.199). The results highlight the validity of neuromarketing-based techniques for predicting the success of advertising responses. Practitioners can consider the proposed methodology at the design stages of advertising content, thus enhancing advertising effectiveness. The study pioneers the use of neurophysiological methods in predicting advertising success in a digital context. This is the first article that has examined whether these measures could actually be used for predicting views for advertising on YouTube.

  18. Consumer Neuroscience-Based Metrics Predict Recall, Liking and Viewing Rates in Online Advertising

    Directory of Open Access Journals (Sweden)

    Jaime Guixeres

    2017-10-01

    Full Text Available The purpose of the present study is to investigate whether the effectiveness of a new ad on digital channels (YouTube can be predicted by using neural networks and neuroscience-based metrics (brain response, heart rate variability and eye tracking. Neurophysiological records from 35 participants were exposed to 8 relevant TV Super Bowl commercials. Correlations between neurophysiological-based metrics, ad recall, ad liking, the ACE metrix score and the number of views on YouTube during a year were investigated. Our findings suggest a significant correlation between neuroscience metrics and self-reported of ad effectiveness and the direct number of views on the YouTube channel. In addition, and using an artificial neural network based on neuroscience metrics, the model classifies (82.9% of average accuracy and estimate the number of online views (mean error of 0.199. The results highlight the validity of neuromarketing-based techniques for predicting the success of advertising responses. Practitioners can consider the proposed methodology at the design stages of advertising content, thus enhancing advertising effectiveness. The study pioneers the use of neurophysiological methods in predicting advertising success in a digital context. This is the first article that has examined whether these measures could actually be used for predicting views for advertising on YouTube.

  19. Consumer Neuroscience-Based Metrics Predict Recall, Liking and Viewing Rates in Online Advertising

    Science.gov (United States)

    Guixeres, Jaime; Bigné, Enrique; Ausín Azofra, Jose M.; Alcañiz Raya, Mariano; Colomer Granero, Adrián; Fuentes Hurtado, Félix; Naranjo Ornedo, Valery

    2017-01-01

    The purpose of the present study is to investigate whether the effectiveness of a new ad on digital channels (YouTube) can be predicted by using neural networks and neuroscience-based metrics (brain response, heart rate variability and eye tracking). Neurophysiological records from 35 participants were exposed to 8 relevant TV Super Bowl commercials. Correlations between neurophysiological-based metrics, ad recall, ad liking, the ACE metrix score and the number of views on YouTube during a year were investigated. Our findings suggest a significant correlation between neuroscience metrics and self-reported of ad effectiveness and the direct number of views on the YouTube channel. In addition, and using an artificial neural network based on neuroscience metrics, the model classifies (82.9% of average accuracy) and estimate the number of online views (mean error of 0.199). The results highlight the validity of neuromarketing-based techniques for predicting the success of advertising responses. Practitioners can consider the proposed methodology at the design stages of advertising content, thus enhancing advertising effectiveness. The study pioneers the use of neurophysiological methods in predicting advertising success in a digital context. This is the first article that has examined whether these measures could actually be used for predicting views for advertising on YouTube. PMID:29163251

  20. Is perfectionism associated with academic burnout through repetitive negative thinking?

    Science.gov (United States)

    Garratt-Reed, David; Howell, Joel; Hayes, Lana; Boyes, Mark

    2018-01-01

    Academic burnout is prevalent among university students, although understanding of what predicts burnout is limited. This study aimed to test the direct and indirect relationship between two dimensions of perfectionism (Perfectionistic Concerns and Perfectionistic Strivings) and the three elements of Academic Burnout (Exhaustion, Inadequacy, and Cynicism) through Repetitive Negative Thinking. In a cross-sectional survey, undergraduate students ( n  = 126, M age = 23.64, 79% female) completed well-validated measures of Perfectionism, Repetitive Negative Thinking, and Academic Burnout. Perfectionistic Concerns was directly associated with all elements of burnout, as well as indirectly associated with Exhaustion and Cynicism via Repetitive Negative Thinking. Perfectionistic Strivings was directly associated with less Inadequacy and Cynicism; however, there were no indirect associations between Perfectionistic Strivings and Academic Burnout operating through Repetitive Negative Thinking. Repetitive Negative Thinking was also directly related to more burnout Exhaustion and Inadequacy, but not Cynicism. It is concluded that future research should investigate whether interventions targeting Perfectionistic Concerns and Repetitive Negative Thinking can reduce Academic Burnout in university students.

  1. Transgenerational effects of environmental enrichment on repetitive motor behavior development.

    Science.gov (United States)

    Bechard, Allison R; Lewis, Mark H

    2016-07-01

    The favorable consequences of environmental enrichment (EE) on brain and behavior development are well documented. Much less is known, however, about transgenerational benefits of EE on non-enriched offspring. We explored whether transgenerational effects of EE might extend to the development of repetitive motor behaviors in deer mice. Repetitive motor behaviors are invariant patterns of movement that, across species, can be reduced by EE. We found that EE not only attenuated the development of repetitive behavior in dams, but also in their non-enriched offspring. Moreover, maternal behavior did not seem to mediate the transgenerational effect we found, although repetitive behavior was affected by reproductive experience. These data support a beneficial transgenerational effect of EE on repetitive behavior development and suggest a novel benefit of reproductive experience. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Electrical strength of vacuum gap at repetitive breakdown

    International Nuclear Information System (INIS)

    Dubinin, N.P.; Chistyakov, N.P.

    1983-01-01

    The investigation of repetitive pulse breakdown of vacuum space, which electrodes have been subjected to various treatment in vacuum and inert gas, is carried out. In case of electrode warm-up in vacuum up to 400 deg C as well as electronic heating up to 900 deg C the voltage in case of repetitive breakdown hasncreased approximately twice and in case of a through treatment, which is accomplished by a high-current glow discharge in inert gas, the maximum high voltage in case of the first breakdown at repetitive breakdown has decreased by 30...40%, remaining 2-3 times higher than in the first case

  3. Face learning and the emergence of view-independent face recognition: an event-related brain potential study.

    Science.gov (United States)

    Zimmermann, Friederike G S; Eimer, Martin

    2013-06-01

    Recognizing unfamiliar faces is more difficult than familiar face recognition, and this has been attributed to qualitative differences in the processing of familiar and unfamiliar faces. Familiar faces are assumed to be represented by view-independent codes, whereas unfamiliar face recognition depends mainly on view-dependent low-level pictorial representations. We employed an electrophysiological marker of visual face recognition processes in order to track the emergence of view-independence during the learning of previously unfamiliar faces. Two face images showing either the same or two different individuals in the same or two different views were presented in rapid succession, and participants had to perform an identity-matching task. On trials where both faces showed the same view, repeating the face of the same individual triggered an N250r component at occipito-temporal electrodes, reflecting the rapid activation of visual face memory. A reliable N250r component was also observed on view-change trials. Crucially, this view-independence emerged as a result of face learning. In the first half of the experiment, N250r components were present only on view-repetition trials but were absent on view-change trials, demonstrating that matching unfamiliar faces was initially based on strictly view-dependent codes. In the second half, the N250r was triggered not only on view-repetition trials but also on view-change trials, indicating that face recognition had now become more view-independent. This transition may be due to the acquisition of abstract structural codes of individual faces during face learning, but could also reflect the formation of associative links between sets of view-specific pictorial representations of individual faces. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Word and nonword repetition in patients with Schizophrenia

    Directory of Open Access Journals (Sweden)

    Alireza Farnam

    2015-08-01

    Full Text Available Introduction: The assessment of the verbal repetition is important in the study of acquired language disorders and neuropsychology. It is helpful in differential diagnosis of aphasia subtypes, auditory breakdowns, and working memory (WM performance. Though different linguistic disorders have been identified in patients with schizophrenia, very little is known about their verbal repetition ability. Methods: The present study was conducted in the inpatient ward of Razi Psychiatric Hospital, Tabriz University of Medical Sciences, Iran, during the year 2013. Participants were: 30 patients diagnosed with schizophrenia during the maintenance phase of treatment and 30 healthy people as control group. They were asked to repeat 15 words and 15 nonwords immediately. The stimuli were 1, 2, and 3 syllabic in Turkish language. Any incorrect repetition scored 1 and correct repetitions scored 0. Lexicalization errors were compared between groups too. Results: Both groups repeated words better than nonwords. Patients showed lower ability to repeat nonwords than controls, especially in 3 syllabics. There was no significant difference in the repetition of words between groups though it was better in controls. Patients with schizophrenia made more errors in both words and nonwords and lexicalization errors were twice more. Conclusion: Lower ability to repeat nonwords (than words in patients with schizophrenia may show the involvement of phonological loop of WM. More lexicalization errors may take place because of dis-inhibition.

  5. DLC coating on stainless steel by pulsed methane discharge in repetitive plasma focus

    International Nuclear Information System (INIS)

    Hassan, M.; Qayyum, A.; Ahmad, S.; Mahmood, S.; Shafiq, M.; Zakaullah, M.; Lee, P.; Rawat, R.S.

    2014-01-01

    Amorphous hydrogenated carbon (a-C:H)/diamond-like carbon (DLC) coatings have been achieved on AISI 304 stainless steel (SS) substrates by employing energetic ions emitted from a repetitive plasma focus operated in CH 4 discharge. The Raman spectroscopy of the coatings exhibits the evolution of a-C:H/DLC coatings with clearly observed D and G peaks centered about 1320–1360 and 1560–1620 cm −1 respectively. The diamond character of the coatings is influenced by the ion flux and repetition rate of the focus device. The repetitive discharge mode of plasma focus has led to the formation of a-C:H/DLC coatings in short duration of time. The coatings transform from a-C to a-C:H depending upon substrate angular position. X-ray diffraction (XRD) analysis confirms the formation of DLC coating owing to stress-induced restructuring in SS. The estimated crystallite size is found to be ∼40–50 nm. Field emission scanning electron micrographs exhibit a layered granular surface morphology of the coatings. The Vickers surface hardness of the DLC coated SS samples has been significantly improved.

  6. DLC coating on stainless steel by pulsed methane discharge in repetitive plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, M., E-mail: hassanjh@gmail.com [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore); Qayyum, A.; Ahmad, S. [National Tokamak Fusion Program, 3329 Islamabad (Pakistan); Mahmood, S. [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore); Department of Physics, University of Karachi, 75270 Karachi (Pakistan); Shafiq, M.; Zakaullah, M. [Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Lee, P.; Rawat, R.S. [Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, BLK7, 1 Nanyang Walk, Singapore 637616 (Singapore)

    2014-06-01

    Amorphous hydrogenated carbon (a-C:H)/diamond-like carbon (DLC) coatings have been achieved on AISI 304 stainless steel (SS) substrates by employing energetic ions emitted from a repetitive plasma focus operated in CH{sub 4} discharge. The Raman spectroscopy of the coatings exhibits the evolution of a-C:H/DLC coatings with clearly observed D and G peaks centered about 1320–1360 and 1560–1620 cm{sup −1} respectively. The diamond character of the coatings is influenced by the ion flux and repetition rate of the focus device. The repetitive discharge mode of plasma focus has led to the formation of a-C:H/DLC coatings in short duration of time. The coatings transform from a-C to a-C:H depending upon substrate angular position. X-ray diffraction (XRD) analysis confirms the formation of DLC coating owing to stress-induced restructuring in SS. The estimated crystallite size is found to be ∼40–50 nm. Field emission scanning electron micrographs exhibit a layered granular surface morphology of the coatings. The Vickers surface hardness of the DLC coated SS samples has been significantly improved.

  7. Radiation-induced changes in DNA methylation of repetitive elements in the mouse heart

    Energy Technology Data Exchange (ETDEWEB)

    Koturbash, Igor, E-mail: ikoturbash@uams.edu [Department of Environmental and Occupational Health, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Miousse, Isabelle R. [Department of Environmental and Occupational Health, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Sridharan, Vijayalakshmi [Division of Radiation Health, Department of Pharmaceutical Sciences, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Nzabarushimana, Etienne; Skinner, Charles M. [Department of Environmental and Occupational Health, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Melnyk, Stepan B.; Pavliv, Oleksandra [Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Hauer-Jensen, Martin [Division of Radiation Health, Department of Pharmaceutical Sciences, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States); Surgical Service, Central Arkansas Veterans Healthcare System, Little Rock, AR 72205 (United States); Nelson, Gregory A. [Departments of Basic Sciences and Radiation Medicine, Loma Linda University, Loma Linda, CA 92354 (United States); Boerma, Marjan [Division of Radiation Health, Department of Pharmaceutical Sciences, University of Arkansas for Medical Sciences, Little Rock, AR 72205 (United States)

    2016-05-15

    Highlights: • Radiation-induced dynamic changes in cardiac DNA methylation were detected. • Early LINE-1 hypomethylation was followed by hypermethylation at a later time-point. • Radiation affected one-carbon metabolism in the heart tissue. • Irradiation resulted in accumulation of satellite DNA mRNA transcripts. - Abstract: DNA methylation is a key epigenetic mechanism, needed for proper control over the expression of genetic information and silencing of repetitive elements. Exposure to ionizing radiation, aside from its strong genotoxic potential, may also affect the methylation of DNA, within the repetitive elements, in particular. In this study, we exposed C57BL/6J male mice to low absorbed mean doses of two types of space radiation—proton (0.1 Gy, 150 MeV, dose rate 0.53 ± 0.08 Gy/min), and heavy iron ions ({sup 56}Fe) (0.5 Gy, 600 MeV/n, dose rate 0.38 ± 0.06 Gy/min). Radiation-induced changes in cardiac DNA methylation associated with repetitive elements were detected. Specifically, modest hypomethylation of retrotransposon LINE-1 was observed at day 7 after irradiation with either protons or {sup 56}Fe. This was followed by LINE-1, and other retrotransposons, ERV2 and SINE B1, as well as major satellite DNA hypermethylation at day 90 after irradiation with {sup 56}Fe. These changes in DNA methylation were accompanied by alterations in the expression of DNA methylation machinery and affected the one-carbon metabolism pathway. Furthermore, loss of transposable elements expression was detected in the cardiac tissue at the 90-day time-point, paralleled by substantial accumulation of mRNA transcripts, associated with major satellites. Given that the one-carbon metabolism pathway can be modulated by dietary modifications, these findings suggest a potential strategy for the mitigation and, possibly, prevention of the negative effects exerted by ionizing radiation on the cardiovascular system. Additionally, we show that the methylation status and

  8. Evaluation of short repetition time, partial flip angle, gradient recalled echo pulse sequences in cervical spine imaging

    International Nuclear Information System (INIS)

    Enzmann, D.; Rubin, J.B.

    1987-01-01

    A short repetition time (TR), partial flip angle, gradient recalled echo pulse sequence (GRASS) was prospectively studied to optimize it for the diagnosis of cervical disk and cord disease in 98 patients. Changes in signal-to-noise ratio (SNR) and contrast were measured as the following parameters were varied: flip angle (3 0 to 18 0 ), TR (22-60 msec), and echo time (TE) (12.5-25 msec). Flip angle was the single most important parameter. For disk disease, cerebrospinal fluid (CSF) SNR peaked at an 8 0 flip angle in the axial view but at a 4 0 flip angle in the sagittal view. In the sagittal view, disk-CSF contrast decreased progressively from a flip angle of 3 0 , while in the axial view it peaked at 10 0 . For cord lesions the findings were similar except that lesion-cord contrast could be increased by lengthening both TR and TE. No one combination of parameters proved greatly superior for either disk disease or cord disease. The selection of parameters required balancing of several factors that often had opposing effects

  9. Two discharge modes of a repetitive nanosecond pulsed helium glow discharge under sub-atmospheric pressure in the repetition frequency range of 20 to 600 kHz

    Science.gov (United States)

    Kikuchi, Yusuke; Maegawa, Takuya; Otsubo, Akira; Nishimura, Yoshimi; Nagata, Masayoshi; Yatsuzuka, Mitsuyasu

    2018-05-01

    Two discharge modes, α and γ, of a repetitive nanosecond pulsed helium glow discharge at a gas pressure of 10 kPa in the repetition frequency range from 20 to 600 kHz are reported for the first time. The pulsed glow discharge is produced in a pair of parallel plate metal electrodes without insertion of dielectrics. The α mode discharge is volumetrically produced in the electrode gap at a low-repetition frequency, whereas the γ mode discharge is localized at the cathode surface at a high-repetition frequency. At high-repetition frequency, the time interval between voltage pulses is shorter than the lifetime of the afterglow produced by the preceding discharge. Then, the γ mode discharge is maintained by a large number of secondary electrons emitted from the cathode exposed to high-density ions and metastable helium atoms in the afterglow. In the α mode discharge with a low-repetition frequency operation, primary electrons due to gas ionization dominate the ionization process. Thus, a large discharge voltage is needed for the excitation of the α mode discharge. It is established that the bifurcation of α-γ discharge mode, accompanied by a decrease in the discharge voltage, occurs at the high-repetition frequency of ∼120 kHz.

  10. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    Energy Technology Data Exchange (ETDEWEB)

    Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Sedin, A. A.; Tugushev, V. I. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz.

  11. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    International Nuclear Information System (INIS)

    Krastelev, E. G.; Sedin, A. A.; Tugushev, V. I.

    2015-01-01

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz

  12. Repetition of Attempted Suicide Among Immigrants in Europe

    Science.gov (United States)

    Lipsicas, Cendrine Bursztein; Mäkinen, Ilkka Henrik; Wasserman, Danuta; Apter, Alan; Kerkhof, Ad; Michel, Konrad; Renberg, Ellinor Salander; van Heeringen, Kees; Värnik, Airi; Schmidtke, Armin

    2014-01-01

    Objectives To compare frequencies of suicide attempt repetition in immigrants and local European populations, and the timing of repetition in these groups. Method: Data from 7 European countries, comprising 10 574 local and 3032 immigrant subjects, were taken from the World Health Organization European Multicentre Study on Suicidal Behaviour and the ensuing Monitoring Suicidal Behaviour in Europe (commonly referred to as MONSUE) project. The relation between immigrant status and repetition of suicide attempt within 12-months following first registered attempt was analyzed with binary logistic regression, controlling for sex, age, and method of attempt. Timing of repetition was controlled for sex, age, and the recommended type of aftercare. Results: Lower odds of repeating a suicide attempt were found in Eastern European (OR 0.50; 95% CI 0.41 to 0.61, P Europe stands in contrast to their markedly higher tendency to attempt suicide in general, possibly pointing to situational stress factors related to their suicidal crisis that are less persistent over time. Our findings also raise the possibility that suicide attempters and repeaters constitute only partially overlapping populations. PMID:25565687

  13. Automatic creation of LabVIEW network shared variables

    International Nuclear Information System (INIS)

    Kluge, T.; Schroeder, H.

    2012-01-01

    We are in the process of preparing the LabVIEW controlled system components of our Solid State Direct Drive experiments for the integration into a Supervisory Control And Data Acquisition (SCADA) or distributed control system. The predetermined route to this is the generation of LabVIEW network shared variables that can easily be exported by LabVIEW to the SCADA system using OLE for Process Control (OPC) or other means. Many repetitive tasks are associated with the creation of the shared variables and the required code. We are introducing an efficient and inexpensive procedure that automatically creates shared variable libraries and sets default values for the shared variables. Furthermore, LabVIEW controls are created that are used for managing the connection to the shared variable inside the LabVIEW code operating on the shared variables. The procedure takes as input an XML spread-sheet defining the required input. The procedure utilizes XSLT and LabVIEW scripting. In a later state of the project the code generation can be expanded to also create code and configuration files that will become necessary in order to access the shared variables from the SCADA system of choice. (authors)

  14. The incidence and repetition of hospital-treated deliberate self harm: findings from the world's first national registry.

    Directory of Open Access Journals (Sweden)

    Ivan J Perry

    Full Text Available Suicide is a significant public health issue with almost one million people dying by suicide each year worldwide. Deliberate self harm (DSH is the single most important risk factor for suicide yet few countries have reliable data on DSH. We developed a national DSH registry in the Republic of Ireland to establish the incidence of hospital-treated DSH at national level and the spectrum and pattern of presentations with DSH and repetition.Between 2003 and 2009, the Irish National Registry of Deliberate Self Harm collected data on DSH presentations to all 40 hospital emergency departments in the country. Data were collected by trained data registration officers using standard methods of case ascertainment and definition. The Registry recorded 75,119 DSH presentations involving 48,206 individuals. The total incidence rate fell from 209 (95% CI: 205-213 per 100,000 in 2003 to 184 (95% CI: 180-189 per 100,000 in 2006 and increased again to 209 (95% CI: 204-213 per 100,000 in 2009. The most notable annual changes were successive 10% increases in the male rate in 2008 and 2009. There was significant variation by age with peak rates in women in the 15-19 year age group (620 (95% CI: 605-636 per 100,000, and in men in the 20-24 age group (427 (95% CI: 416-439 per 100,000. Repetition rates varied significantly by age, method of self harm and number of previous episodes.Population-based data on hospital-treated DSH represent an important index of the burden of mental illness and suicide risk in the community. The increased DSH rate in Irish men in 2008 and 2009 coincided with the advent of the economic recession in Ireland. The findings underline the need for developing effective interventions to reduce DSH repetition rates as a key priority for health systems.

  15. The development of interactive multimedia based on auditory, intellectually, repetition in repetition algorithm learning to increase learning outcome

    Science.gov (United States)

    Munir; Sutarno, H.; Aisyah, N. S.

    2018-05-01

    This research aims to find out how the development of interactive multimedia based on auditory, intellectually, and repetition can improve student learning outcomes. This interactive multimedia is developed through 5 stages. Analysis stages include the study of literature, questionnaire, interviews and observations. The design phase is done by the database design, flowchart, storyboards and repetition algorithm material while the development phase is done by the creation of web-based framework. Presentation material is adapted to the model of learning such as auditory, intellectually, repetition. Auditory points are obtained by recording the narrative material that presented by a variety of intellectual points. Multimedia as a product is validated by material and media experts. Implementation phase conducted on grade XI-TKJ2 SMKN 1 Garut. Based on index’s gain, an increasing of student learning outcomes in this study is 0.46 which is fair due to interest of student in using interactive multimedia. While the multimedia assessment earned 84.36% which is categorized as very well.

  16. Repetition suppression and repetition enhancement underlie auditory memory-trace formation in the human brain: an MEG study.

    Science.gov (United States)

    Recasens, Marc; Leung, Sumie; Grimm, Sabine; Nowak, Rafal; Escera, Carles

    2015-03-01

    The formation of echoic memory traces has traditionally been inferred from the enhanced responses to its deviations. The mismatch negativity (MMN), an auditory event-related potential (ERP) elicited between 100 and 250ms after sound deviation is an indirect index of regularity encoding that reflects a memory-based comparison process. Recently, repetition positivity (RP) has been described as a candidate ERP correlate of direct memory trace formation. RP consists of repetition suppression and enhancement effects occurring in different auditory components between 50 and 250ms after sound onset. However, the neuronal generators engaged in the encoding of repeated stimulus features have received little interest. This study intends to investigate the neuronal sources underlying the formation and strengthening of new memory traces by employing a roving-standard paradigm, where trains of different frequencies and different lengths are presented randomly. Source generators of repetition enhanced (RE) and suppressed (RS) activity were modeled using magnetoencephalography (MEG) in healthy subjects. Our results show that, in line with RP findings, N1m (~95-150ms) activity is suppressed with stimulus repetition. In addition, we observed the emergence of a sustained field (~230-270ms) that showed RE. Source analysis revealed neuronal generators of RS and RE located in both auditory and non-auditory areas, like the medial parietal cortex and frontal areas. The different timing and location of neural generators involved in RS and RE points to the existence of functionally separated mechanisms devoted to acoustic memory-trace formation in different auditory processing stages of the human brain. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Frequency Adaptive Repetitive Control of Grid-Tied Three-Phase PV Inverters

    DEFF Research Database (Denmark)

    Zhou, Keliang; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    Repetitive control offers an accurate current control scheme for grid-tied converters to feed high quality sinusoidal current into the grid. However, with grid frequency being treated as a constant value, conventional repetitive controller fail to produce high quality feeding current in the prese......Repetitive control offers an accurate current control scheme for grid-tied converters to feed high quality sinusoidal current into the grid. However, with grid frequency being treated as a constant value, conventional repetitive controller fail to produce high quality feeding current...

  18. DC-driven plasma gun: self-oscillatory operation mode of atmospheric-pressure helium plasma jet comprised of repetitive streamer breakdowns

    Science.gov (United States)

    Wang, Xingxing; Shashurin, Alexey

    2017-02-01

    This paper presents and studies helium atmospheric pressure plasma jet comprised of a series of repetitive streamer breakdowns, which is driven by pure DC high voltage (self-oscillatory behavior). The repetition frequency of the breakdowns is governed by the geometry of discharge electrodes/surroundings and gas flow rate. Each next streamer is initiated when the electric field on the anode tip recovers after the previous breakdown and reaches the breakdown threshold value of about 2.5 kV cm-1. One type of the helium plasma gun designed using this operational principle is demonstrated. The gun operates on about 3 kV DC high voltage and is comprised of the series of the repetitive streamer breakdowns at a frequency of about 13 kHz.

  19. The effects of training with loads that maximise power output and individualised repetitions vs. traditional power training.

    Directory of Open Access Journals (Sweden)

    J M Sarabia

    Full Text Available It has been suggested that strength training effects (i.e. neural or structural vary, depending on the total repetitions performed and velocity loss in each training set.The aim of this study is to compare the effects of two training programmes (i.e. one with loads that maximise power output and individualised repetitions, and the other following traditional power training.Twenty-five males were divided into three groups (optimum power [OP = 10], traditional training [TT = 9] and control group [CG = 6]. The training load used for OP was individualised using loads that maximised power output (41.7% ± 5.8 of one repetition maximum [1RM] and repetitions at maximum power (4 to 9 repetitions, or 'reps'. Volume (sets x repetitions was the same for both experimental groups, while intensity for TT was that needed to perform only 50% of the maximum number of possible repetitions (i.e. 61.1%-66.6% of 1RM. The training programme ran over 11 weeks (2 sessions per week; 4-5 sets per session; 3-minute rests between sets, with pre-, intermediate and post-tests which included: anthropometry, 1RM, peak power output (PPO with 30%, 40% and 50% of 1RM in the bench press throw, and salivary testosterone (ST and cortisol (SC concentrations. Rate of perceived exertion (RPE and power output were recorded in all sessions.Following the intermediate test, PPO was increased in the OP group for each load (10.9%-13.2%. Following the post-test, both experimental groups had increased 1RM (11.8%-13.8% and PPO for each load (14.1%-19.6%. Significant decreases in PPO were found for the TT group during all sets (4.9%-15.4%, along with significantly higher RPE (37%.OP appears to be a more efficient method of training, with less neuromuscular fatigue and lower RPE.

  20. Autism and exergaming: effects on repetitive behaviors and cognition

    Directory of Open Access Journals (Sweden)

    Anderson-Hanley C

    2011-09-01

    Full Text Available Cay Anderson-Hanley, Kimberly Tureck, Robyn L Schneiderman Department of Psychology, Union College, Schenectady, NY, USA Abstract: Autism is a neurodevelopmental disorder that leads to impairment in social skills and delay in language development, and results in repetitive behaviors and restricted interests that impede academic and social involvement. Physical exercise has been shown to decrease repetitive behaviors in autistic children and improve cognitive function across the life-span. Exergaming combines physical and mental exercise simultaneously by linking physical activity movements to video game control and may yield better compliance with exercise. In this investigation, two pilot studies explored the potential behavioral and cognitive benefits of exergaming. In Pilot I, twelve children with autism spectrum disorders completed a control task and an acute bout of Dance Dance Revolution (DDR; in Pilot II, ten additional youths completed an acute bout of cyber cycling. Repetitive behaviors and executive function were measured before and after each activity. Repetitive behaviors significantly decreased, while performance on Digits Backwards improved following the exergaming conditions compared with the control condition. Additional research is needed to replicate these findings, and to explore the application of exergaming for the management of behavioral disturbance and to increase cognitive control in children on the autism spectrum. Keywords: autism, repetitive behaviors, exergaming, exercise, executive function

  1. A longitudinal investigation of perfectionism and repetitive negative thinking in perinatal depression.

    Science.gov (United States)

    Egan, Sarah J; Kane, Robert T; Winton, Karen; Eliot, Catherine; McEvoy, Peter M

    2017-10-01

    Repetitive negative thinking and perfectionism have both been proposed as processes that are related to depressive symptoms. The purpose of this study was to investigate concurrent and prospective relationships between antenatal and postnatal depression, perfectionism, and repetitive negative thinking. A longitudinal design was used and 71 women were followed from their third trimester of pregnancy to six weeks post birth. A structural equation model was tested with antenatal perfectionism predicting antenatal repetitive negative thinking, perfectionism predicting postnatal depression, and antenatal repetitive negative thinking predicting antenatal and postnatal depression. The final model provided an adequate fit to the data but the pathway from antenatal repetitive negative thinking to postnatal depression was not significant. The findings provide support for the role of perfectionism and repetitive negative thinking in the onset and maintenance of perinatal symptoms of depression. It is suggested that future research investigates the efficacy of targeting repetitive negative thinking and perfectionism in pregnancy to examine if this can reduce perinatal depression. Copyright © 2017. Published by Elsevier Ltd.

  2. Concreteness of Positive, Negative, and Neutral Repetitive Thinking About the Future

    Science.gov (United States)

    Behar, Evelyn; McGowan, Sarah Kate; McLaughlin, Katie A.; Borkovec, T.D.; Goldwin, Michelle; Bjorkquist, Olivia

    2014-01-01

    Consistent with assertions that the adaptiveness of repetitive thinking is influenced by both its valence and style, Stöber (e.g., Stöber & Borkovec, 2002) has argued that worry is characterized by a reduced concreteness of thought content and that the resulting abstractness contributes to its inhibition of some aspects of anxious responding. However, extant research does not provide a direct test of Stöber’s reduced concreteness theory of worry. We sought to test Stöber’s theory and to examine the adaptiveness of repetitive worrisome thinking by randomly assigning 108 participants to engage in five consecutive periods of repetitive thinking about positively, negatively, or neutrally valenced potential future events. Results based on coding of thought data indicated that (a) repetitive thinking became increasingly less concrete as periods progressed; (b) contrary to Stöber’s theory, both negative and positive repetitive future thinking were more concrete than neutral repetitive future thinking (and did not differ from each other); and (c) abstractness of thought during negative repetitive future thinking was associated with reduced reports of imagery-based activity. Results based on self-reported affect indicated that negatively valenced repetitive future thinking was uniquely associated with initial decreases in anxious affect, followed by increased anxious affect that coincided with increased imagery-based activity. This suggests that worry is associated with a sequential mitigation of anxious meaning followed by a strengthening of anxious meaning over time. Theoretical and clinical implications of these findings are discussed. PMID:22440067

  3. Effects of repetition and temperature on Contingent Electrical Stimulation

    DEFF Research Database (Denmark)

    Castrillon, Eduardo E.; Zhou, Xinwen; Svensson, Peter

    ) activity associated with bruxism. Repetition of the electrical stimulus and skin surface temperature (ST) may affect the perception of CES and possibly also the inhibitory EMG effects.Objectives: To determine the effects of stimulus repetition and skin ST on the perception of CES.  Methods: Healthy...

  4. Problem-solving ability and repetition of deliberate self-harm: a multicentre study.

    Science.gov (United States)

    McAuliffe, Carmel; Corcoran, Paul; Keeley, Helen S; Arensman, Ella; Bille-Brahe, Unni; De Leo, Diego; Fekete, Sandor; Hawton, Keith; Hjelmeland, Heidi; Kelleher, Margaret; Kerkhof, Ad J F M; Lönnqvist, Jouko; Michel, Konrad; Salander-Renberg, Ellinor; Schmidtke, Armin; Van Heeringen, Kees; Wasserman, Danuta

    2006-01-01

    While recent studies have found problem-solving impairments in individuals who engage in deliberate self-harm (DSH), few studies have examined repeaters and non-repeaters separately. The aim of the present study was to investigate whether specific types of problem-solving are associated with repeated DSH. As part of the WHO/EURO Multicentre Study on Suicidal Behaviour, 836 medically treated DSH patients (59% repeaters) from 12 European regions were interviewed using the European Parasuicide Study Interview Schedule (EPSIS II) approximately 1 year after their index episode. The Utrecht Coping List (UCL) assessed habitual responses to problems. Factor analysis identified five dimensions--Active Handling, Passive-Avoidance, Problem Sharing, Palliative Reactions and Negative Expression. Passive-Avoidance--characterized by a pre-occupation with problems, feeling unable to do anything, worrying about the past and taking a gloomy view of the situation, a greater likelihood of giving in so as to avoid difficult situations, the tendency to resign oneself to the situation, and to try to avoid problems--was the problem-solving dimension most strongly associated with repetition, although this association was attenuated by self-esteem. The outcomes of the study indicate that treatments for DSH patients with repeated episodes should include problem-solving interventions. The observed passivity and avoidance of problems (coupled with low self-esteem) associated with repetition suggests that intensive therapeutic input and follow-up are required for those with repeated DSH.

  5. ChiMS: Open-source instrument control software platform on LabVIEW for imaging/depth profiling mass spectrometers.

    Science.gov (United States)

    Cui, Yang; Hanley, Luke

    2015-06-01

    ChiMS is an open-source data acquisition and control software program written within LabVIEW for high speed imaging and depth profiling mass spectrometers. ChiMS can also transfer large datasets from a digitizer to computer memory at high repetition rate, save data to hard disk at high throughput, and perform high speed data processing. The data acquisition mode generally simulates a digital oscilloscope, but with peripheral devices integrated for control as well as advanced data sorting and processing capabilities. Customized user-designed experiments can be easily written based on several included templates. ChiMS is additionally well suited to non-laser based mass spectrometers imaging and various other experiments in laser physics, physical chemistry, and surface science.

  6. Post-exercise cortical depression following repetitive passive finger movement.

    Science.gov (United States)

    Otsuka, Ryohei; Sasaki, Ryoki; Tsuiki, Shota; Kojima, Sho; Onishi, Hideaki

    2017-08-24

    This study aimed to clarify the influence of range of repetitive passive finger movement on corticospinal excitability. Thirteen healthy subjects participated in this study. Passive index finger adduction-abduction movements were performed from 15° abduction to 15° adduction, 15° abduction to 0°, 0° to 15° adduction, and 15° adduction to 30° adduction, each at 15°/s for 10min on separate days. Motor evoked potentials (MEPs) elicited by transcranial magnetic stimulation and M- and F-waves were measured before and after each repetitive passive index finger movement protocol to evaluate changes in corticospinal excitability. MEP amplitude significantly decreased after all passive movements, while F-wave amplitude, F-wave persistence, and M-wave amplitude remained stable. These results suggest that cortical excitability decreases after repetitive passive movement. However, the range of repetitive passive movement does not markedly influence the magnitude of cortical depression. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Evidence-Based Behavioral Interventions for Repetitive Behaviors in Autism

    Science.gov (United States)

    Boyd, Brian A.; McDonough, Stephen G.; Bodfish, James W.

    2012-01-01

    Restricted and repetitive behaviors (RRBs) are a core symptom of autism spectrum disorders (ASD). There has been an increased research emphasis on repetitive behaviors; however, this research primarily has focused on phenomenology and mechanisms. Thus, the knowledge base on interventions is lagging behind other areas of research. The literature…

  8. Repetitive sequences: the hidden diversity of heterochromatin in prochilodontid fish

    Directory of Open Access Journals (Sweden)

    Maria L. Terencio

    2015-08-01

    Full Text Available The structure and organization of repetitive elements in fish genomes are still relatively poorly understood, although most of these elements are believed to be located in heterochromatic regions. Repetitive elements are considered essential in evolutionary processes as hotspots for mutations and chromosomal rearrangements, among other functions – thus providing new genomic alternatives and regulatory sites for gene expression. The present study sought to characterize repetitive DNA sequences in the genomes of Semaprochilodus insignis (Jardine & Schomburgk, 1841 and Semaprochilodus taeniurus (Valenciennes, 1817 and identify regions of conserved syntenic blocks in this genome fraction of three species of Prochilodontidae (S. insignis, S. taeniurus, and Prochilodus lineatus (Valenciennes, 1836 by cross-FISH using Cot-1 DNA (renaturation kinetics probes. We found that the repetitive fractions of the genomes of S. insignis and S. taeniurus have significant amounts of conserved syntenic blocks in hybridization sites, but with low degrees of similarity between them and the genome of P. lineatus, especially in relation to B chromosomes. The cloning and sequencing of the repetitive genomic elements of S. insignis and S. taeniurus using Cot-1 DNA identified 48 fragments that displayed high similarity with repetitive sequences deposited in public DNA databases and classified as microsatellites, transposons, and retrotransposons. The repetitive fractions of the S. insignis and S. taeniurus genomes exhibited high degrees of conserved syntenic blocks in terms of both the structures and locations of hybridization sites, but a low degree of similarity with the syntenic blocks of the P. lineatus genome. Future comparative analyses of other prochilodontidae species will be needed to advance our understanding of the organization and evolution of the genomes in this group of fish.

  9. Hemispheric Asymmetries in Repetition Enhancement and Suppression Effects in the Newborn Brain.

    Science.gov (United States)

    Bouchon, Camillia; Nazzi, Thierry; Gervain, Judit

    2015-01-01

    The repeated presentation of stimuli typically attenuates neural responses (repetition suppression) or, less commonly, increases them (repetition enhancement) when stimuli are highly complex, degraded or presented under noisy conditions. In adult functional neuroimaging research, these repetition effects are considered as neural correlates of habituation. The development and respective functional significance of these effects in infancy remain largely unknown. This study investigates repetition effects in newborns using functional near-infrared spectroscopy, and specifically the role of stimulus complexity in evoking a repetition enhancement vs. a repetition suppression response, following up on Gervain et al. (2008). In that study, abstract rule-learning was found at birth in cortical areas specific to speech processing, as evidenced by a left-lateralized repetition enhancement of the hemodynamic response to highly variable speech sequences conforming to a repetition-based ABB artificial grammar, but not to a random ABC grammar. Here, the same paradigm was used to investigate how simpler stimuli (12 different sequences per condition as opposed to 140), and simpler presentation conditions (blocked rather than interleaved) would influence repetition effects at birth. Results revealed that the two grammars elicited different dynamics in the two hemispheres. In left fronto-temporal areas, we reproduce the early perceptual discrimination of the two grammars, with ABB giving rise to a greater response at the beginning of the experiment than ABC. In addition, the ABC grammar evoked a repetition enhancement effect over time, whereas a stable response was found for the ABB grammar. Right fronto-temporal areas showed neither initial discrimination, nor change over time to either pattern. Taken together with Gervain et al. (2008), this is the first evidence that manipulating methodological factors influences the presence or absence of neural repetition enhancement effects in

  10. Hemispheric Asymmetries in Repetition Enhancement and Suppression Effects in the Newborn Brain.

    Directory of Open Access Journals (Sweden)

    Camillia Bouchon

    Full Text Available The repeated presentation of stimuli typically attenuates neural responses (repetition suppression or, less commonly, increases them (repetition enhancement when stimuli are highly complex, degraded or presented under noisy conditions. In adult functional neuroimaging research, these repetition effects are considered as neural correlates of habituation. The development and respective functional significance of these effects in infancy remain largely unknown.This study investigates repetition effects in newborns using functional near-infrared spectroscopy, and specifically the role of stimulus complexity in evoking a repetition enhancement vs. a repetition suppression response, following up on Gervain et al. (2008. In that study, abstract rule-learning was found at birth in cortical areas specific to speech processing, as evidenced by a left-lateralized repetition enhancement of the hemodynamic response to highly variable speech sequences conforming to a repetition-based ABB artificial grammar, but not to a random ABC grammar.Here, the same paradigm was used to investigate how simpler stimuli (12 different sequences per condition as opposed to 140, and simpler presentation conditions (blocked rather than interleaved would influence repetition effects at birth.Results revealed that the two grammars elicited different dynamics in the two hemispheres. In left fronto-temporal areas, we reproduce the early perceptual discrimination of the two grammars, with ABB giving rise to a greater response at the beginning of the experiment than ABC. In addition, the ABC grammar evoked a repetition enhancement effect over time, whereas a stable response was found for the ABB grammar. Right fronto-temporal areas showed neither initial discrimination, nor change over time to either pattern.Taken together with Gervain et al. (2008, this is the first evidence that manipulating methodological factors influences the presence or absence of neural repetition enhancement

  11. A repetitive elements perspective in Polycomb epigenetics.

    Directory of Open Access Journals (Sweden)

    Valentina eCasa

    2012-10-01

    Full Text Available Repetitive elements comprise over two-thirds of the human genome. For a long time, these elements have received little attention since they were considered non functional. On the contrary, recent evidence indicates that they play central roles in genome integrity, gene expression and disease. Indeed, repeats display meiotic instability associated with disease and are located within common fragile sites, which are hotspots of chromosome rearrangements in tumors. Moreover, a variety of diseases have been associated with aberrant transcription of repetitive elements. Overall this indicates that appropriate regulation of repetitive elements’ activity is fundamental.Polycomb group (PcG proteins are epigenetic regulators that are essential for the normal development of multicellular organisms. Mammalian PcG proteins are involved in fundamental processes, such as cellular memory, cell proliferation, genomic imprinting, X-inactivation, and cancer development. PcG proteins can convey their activity through long-distance interactions also on different chromosomes. This indicates that the 3D organization of PcG proteins contributes significantly to their function. However, it is still unclear how these complex mechanisms are orchestrated and which role PcG proteins play in the multi-level organization of gene regulation. Intriguingly, the greatest proportion of Polycomb-mediated chromatin modifications is located in genomic repeats and it has been suggested that they could provide a binding platform for Polycomb proteins.Here, these lines of evidence are woven together to discuss how repetitive elements could contribute to chromatin organization in the 3D nuclear space.

  12. Application of repetitive pulsed power technology to chemical processing

    International Nuclear Information System (INIS)

    Kaye, R.J.; Hamil, R.

    1995-01-01

    The numerous sites of soil and water contaminated with organic chemicals present an urgent environmental concern that continues to grow. Electron and x-ray irradiation have been shown to be effective methods to destroy a wide spectrum of organic chemicals, nitrates, nitrites, and cyanide in water by breaking molecules to non-toxic products or entirely mineralizing the by-products to gas, water, and salts. Sandia National Laboratories is developing Repetitive High Energy Pulsed Power (RHEPP) technology capable of producing high average power, broad area electron or x-ray beams. The 300 kW RHEPP-II facility accelerates electrons to 2.5 MeV at 25 kA over 1,000 cm 2 in 60 ns pulses at repetition rates of over 100 Hz. Linking this modular treatment capability with the rapid optical-sensing diagnostics and neutral network characterization software algorithms will provide a Smart Waste Treatment (SWaT) system. Such a system would also be applicable for chemical manufacture and processing of industrial waste for reuse or disposal. This talk describes both the HREPP treatment capability and sensing technologies. Measurements of the propagated RHEPP-II beam and dose profiles are presented. Sensors and rapid detection software are discussed with application toward chemical treatment

  13. The roles of stimulus repetition and hemispheric activation in visual half-field asymmetries.

    Science.gov (United States)

    Sullivan, K F; McKeever, W F

    1985-10-01

    Hardyck, Tzeng, and Wang (1978, Brain and Language, 5, 56-71) hypothesized that ample repetition of a small number of stimuli is required in order to obtain VHF differences in tachistoscopic tasks. Four experiments, with varied levels of repetition, were conducted to test this hypothesis. Three experiments utilized the general task of object-picture naming and one utilized a word-naming task. Naming latencies constituted the dependent measure. The results demonstrate that for the object-naming paradigm repetition is required for RVF superiority to emerge. Repetition was found to be unnecessary for RVF superiority in the word-naming paradigm, with repetition actually reducing RVF superiority. Experiment I suggested the possibility that RVF superiority developed for the second half of the trials as a function of practice or hemispheric activation, regardless of repetition level. Subsequent experiments, better designed to assess this possibility, clearly refuted it. It was concluded that the effect of repetition depends on the processing requirements of the task. We propose that, for tasks which can be processed efficiently by one hemisphere, the effect of repetition will be to reduce VHF asymmetries; but tasks requiring substantial processing by both hemispheres will show shifts to RVF superiority as a function of repetition.

  14. Post-acquisition repetitive thought in fear conditioning: an experimental investigation of the effect of CS-US-rehearsal.

    Science.gov (United States)

    Joos, Els; Vansteenwegen, Debora; Hermans, Dirk

    2012-06-01

    Although repetitive thought (e.g., worry) is generally assumed to be a risk factor for psychopathological disorders such as anxiety disorders, the repetitive thought processes occurring after a conditioning event have not yet received much theoretical attention. However, as repetitive thought can be mimicked by (mental) rehearsal, which is well-known to enhance memory performance, it seems worthwhile to explore the role of rehearsal in conditioning. Therefore, the current study investigates the impact of rehearsing an acquired CS-US-contingency on subsequent conditioned fear responding. After acquiring two CS-US-contingencies with either a human scream or a white noise as US, participants were instructed to rehearse one of these CS-US-pairings during an experimental session as well as during the following week. Fear responding to the CS which was previously paired with the scream persisted in the participants who rehearsed the CS-US(scream)-contingency, but decreased in those participants who rehearsed the CS-US(noise)-contingency. The same pattern emerged in the US-expectancy ratings, but the effect failed to reach significance. For the CS which was paired with the noise-US, no rehearsal effect emerged. As acquisition to the noise-US was less pronounced and less robust as compared to the scream-US, claims regarding the rehearsal effect might be hampered for the CS-US(noise)-contingency. Repetitive post-acquisition activation of a CS-US-contingency impacts CR retention. As the USs were not rated as more intense, aversive or startling after rehearsal compared to post-acquisition, US-inflation is discarded as a possible explanation of this effect. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Repetitively pulsed, double discharge TEA CO/sub 2/ laser

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, D C; James, D J; Ramsden, S A

    1975-10-01

    The design and operation of a repetitively pulsed TEA CO/sub 2/ laser is described. Average powers of up to 400 W at a repetition frequency of 200 pulses/s have been obtained. The system has also been used to provide long pulses (over 20 ..mu..s) and tunable single axial mode pulses.

  16. Modeling repetitive motions using structured light.

    Science.gov (United States)

    Xu, Yi; Aliaga, Daniel G

    2010-01-01

    Obtaining models of dynamic 3D objects is an important part of content generation for computer graphics. Numerous methods have been extended from static scenarios to model dynamic scenes. If the states or poses of the dynamic object repeat often during a sequence (but not necessarily periodically), we call such a repetitive motion. There are many objects, such as toys, machines, and humans, undergoing repetitive motions. Our key observation is that when a motion-state repeats, we can sample the scene under the same motion state again but using a different set of parameters; thus, providing more information of each motion state. This enables robustly acquiring dense 3D information difficult for objects with repetitive motions using only simple hardware. After the motion sequence, we group temporally disjoint observations of the same motion state together and produce a smooth space-time reconstruction of the scene. Effectively, the dynamic scene modeling problem is converted to a series of static scene reconstructions, which are easier to tackle. The varying sampling parameters can be, for example, structured-light patterns, illumination directions, and viewpoints resulting in different modeling techniques. Based on this observation, we present an image-based motion-state framework and demonstrate our paradigm using either a synchronized or an unsynchronized structured-light acquisition method.

  17. Body-focused repetitive behavior disorders in ICD-11

    Directory of Open Access Journals (Sweden)

    Jon E. Grant

    2014-01-01

    Full Text Available This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  18. Determination of trace amounts of plutonium in environmental samples by RIMS using a high repetition rate solid state laser system

    International Nuclear Information System (INIS)

    Gruening, C.; Kratz, J.V.; Trautmann, N.; Waldek, A.; Huber, G.; Passler, G.; Wendt, K.

    2001-01-01

    A reliable and easy to handle high repetition rate solid state laser system has been set up for routine applications of Resonance Ionization Mass Spectrometry (RIMS). It consists of three Titanium-Sapphire (Ti:Sa) lasers pumped by one Nd:YAG laser, providing up to 3 W of tunable laser light each in a wavelength range from 725 nm to 895 nm. The isotope shifts for 238 Pu to 244 Pu have been measured in an efficient ionization scheme with λ 1 =420.76 nm, λ 2 =847.28 nm and λ 3 =767.53 nm. An overall detection efficiency of the RIMS apparatus of ε=1x10 -5 is routinely reached, resulting in a detection limit of 2x10 6 atoms (0.8 fg) of plutonium. The isotopic compositions of synthetic samples and the NIST standard reference material SRM996 were measured. The content of 238 Pu to 242 Pu has been determined in dust samples from the surroundings of a nuclear power plant and 244 Pu was determined in urine samples for the National Radiation Protection Board (NRPB), U.K. Routine operation of plutonium ultratrace detection could thus be established

  19. Repetitively pulsed power for meat pasteurization

    International Nuclear Information System (INIS)

    Patterson, E.L.; Kaye, R.J.; Neau, E.L.

    1994-01-01

    Electronic pasteurization of meat offers the potential for drastically reducing the incidence of food poisoning caused by biological pathogens accidentally introduced into meat products. Previous work has shown that γ-rays are an effective method of destroying E. coli 0157:H7, Salmonella, C. jejuni, L. monocytogenes, Listeria, and S. aureus bacteria types. The concern with the use of γ-rays is that radioactive material must be used in the pasteurization process that can lead to some market resistance and activist pressure on the meat industry. The use of accelerator generated high average power electron beams, at energies less than 10 MeV, or X-rays, with energies below 5 MeV, have been approved by the FDA for use in pasteurizing foods. Accelerator produced electronic pasteurization has the advantage that no radioactive material inventory is required. Electronic pasteurization has the additional benefit that it removes bacterial pathogens on the meat surface as well as within the volume of the meat product. High average power, repetitively-pulsed, broad-area electron beam sources being developed in the RHEPP program are suitable for large scale meat treatment in packing plant environments. RHEPP-II, which operates at 2.5 MeV and 25 kA at pulse repetition frequencies up to 120 Hz has adequate electron energy to penetrate hamburger patties which comprise about half of the beef consumption in the United States. Ground beef also has the highest potential for contamination since considerable processing is required in its production. A meat pasteurization facility using this size of accelerator source should be capable of treating 10 6 pounds of hamburger patties per hour to a dose of up to 3 kGy (300 kilorads). The RHEPP modular accelerator technology can easily be modified for other production rates and types of products

  20. The effects of training with loads that maximise power output and individualised repetitions vs. traditional power training

    Science.gov (United States)

    Moya-Ramón, M.; Hernández-Davó, J. L.; Fernandez-Fernandez, J.; Sabido, R.

    2017-01-01

    Background It has been suggested that strength training effects (i.e. neural or structural) vary, depending on the total repetitions performed and velocity loss in each training set. Purpose The aim of this study is to compare the effects of two training programmes (i.e. one with loads that maximise power output and individualised repetitions, and the other following traditional power training). Methods Twenty-five males were divided into three groups (optimum power [OP = 10], traditional training [TT = 9] and control group [CG = 6]). The training load used for OP was individualised using loads that maximised power output (41.7% ± 5.8 of one repetition maximum [1RM]) and repetitions at maximum power (4 to 9 repetitions, or ‘reps’). Volume (sets x repetitions) was the same for both experimental groups, while intensity for TT was that needed to perform only 50% of the maximum number of possible repetitions (i.e. 61.1%–66.6% of 1RM). The training programme ran over 11 weeks (2 sessions per week; 4–5 sets per session; 3-minute rests between sets), with pre-, intermediate and post-tests which included: anthropometry, 1RM, peak power output (PPO) with 30%, 40% and 50% of 1RM in the bench press throw, and salivary testosterone (ST) and cortisol (SC) concentrations. Rate of perceived exertion (RPE) and power output were recorded in all sessions. Results Following the intermediate test, PPO was increased in the OP group for each load (10.9%–13.2%). Following the post-test, both experimental groups had increased 1RM (11.8%–13.8%) and PPO for each load (14.1%–19.6%). Significant decreases in PPO were found for the TT group during all sets (4.9%–15.4%), along with significantly higher RPE (37%). Conclusion OP appears to be a more efficient method of training, with less neuromuscular fatigue and lower RPE. PMID:29053725

  1. Television Viewing and Its Association with Sedentary Behaviors, Self-Rated Health and Academic Performance among Secondary School Students in Peru

    Directory of Open Access Journals (Sweden)

    Bimala Sharma

    2017-04-01

    Full Text Available The study assessed television viewing >2 h a day and its association with sedentary behaviors, self-rated health, and academic performance among secondary school adolescents. A cross-sectional survey was conducted among randomly selected students in Lima in 2015. We measured self-reported responses of students using a standard questionnaire, and conducted in-depth interviews with 10 parents and 10 teachers. Chi-square test, correlation and multivariate logistic regression analysis were performed among 1234 students, and thematic analysis technique was used for qualitative information. A total of 23.1% adolescents reported watching television >2 h a day. Qualitative findings also show that adolescents spend most of their leisure time watching television, playing video games or using the Internet. Television viewing had a significant positive correlation with video game use in males and older adolescents, with Internet use in both sexes, and a negative correlation with self-rated health and academic performance in females. Multivariate logistic regression analysis shows that television viewing >2 h a day, independent of physical activity was associated with video games use >2 h a day, Internet use >2 h a day, poor/fair self-rated health and poor self-reported academic performance. Television viewing time and sex had a significant interaction effect on both video game use >2 h a day and Internet use >2 h a day. Reducing television viewing time may be an effective strategy for improving health and academic performance in adolescents.

  2. Television Viewing and Its Association with Sedentary Behaviors, Self-Rated Heath and Academic Performance among Secondary School Students in Peru.

    Science.gov (United States)

    Sharma, Bimala; Cosme Chavez, Rosemary; Jeong, Ae Suk; Nam, Eun Woo

    2017-04-05

    The study assessed television viewing >2 h a day and its association with sedentary behaviors, self-rated health, and academic performance among secondary school adolescents. A cross-sectional survey was conducted among randomly selected students in Lima in 2015. We measured self-reported responses of students using a standard questionnaire, and conducted in-depth interviews with 10 parents and 10 teachers. Chi-square test, correlation and multivariate logistic regression analysis were performed among 1234 students, and thematic analysis technique was used for qualitative information. A total of 23.1% adolescents reported watching television >2 h a day. Qualitative findings also show that adolescents spend most of their leisure time watching television, playing video games or using the Internet. Television viewing had a significant positive correlation with video game use in males and older adolescents, with Internet use in both sexes, and a negative correlation with self-rated health and academic performance in females. Multivariate logistic regression analysis shows that television viewing >2 h a day, independent of physical activity was associated with video games use >2 h a day, Internet use >2 h a day, poor/fair self-rated health and poor self-reported academic performance. Television viewing time and sex had a significant interaction effect on both video game use >2 h a day and Internet use >2 h a day. Reducing television viewing time may be an effective strategy for improving health and academic performance in adolescents.

  3. Repetitive laser fusion experiment and operation using a target injection system

    International Nuclear Information System (INIS)

    Nishimura, Yasuhiko; Komeda, Osamu; Mori, Yoshitaka

    2017-01-01

    Since 2008, a collaborative research project on laser fusion development based on a high-speed ignition method using repetitive laser has been carried out with several collaborative research institutes. This paper reports the current state of operation of high repetition laser fusion experiments, such as target introduction and control based on a target injection system that allows free falling under 1 Hz, using a high repetition laser driver that has been under research and development, as well as the measurement of targets that freely fall. The HAMA laser driver that enabled high repetition fusion experiments is a titanium sapphire laser using a diode-pumped solid-state laser KURE-I of green light output as a driver pump light source. In order to carry out high repetition laser fusion experiments, the target injection device allows free falling of deuterated polystyrene solid sphere targets of 1 mm in diameter under 1 Hz. The authors integrated the developed laser and injection system, and succeeded first in the world in making the nuclear fusion reaction continuously by hitting the target to be injected with laser, which is essential technology for future laser nuclear fusion reactor. In order to realize repetition laser fusion experiments, stable laser, target synchronization control, and target position measurement technologies are indispensable. (A.O.)

  4. Laser diagnostic and therapy of dental caries: the clinic point of view; Laser diagnostico e tratamento da carie dental: uma visao clinica

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Priscila Faria

    2001-07-01

    Dental caries's diagnosis is a major dentistry problem from the clinic point of view. The laser beam on the region of 655 nm induces the fluorescence of the compounds present in the hard tissue, quantifying differences between sound and carious enamel and dentine. Diagnodent (Kavo, Germany), showed to be effective regarding dental caries's diagnosis in the present research sampling. The Er:YAG laser (Kavo Key Laser 2, Germany) performed efficient cavity preparations in caries lesions of I and V class type, using up energies that ranged from 300 mJ to 350 mJ with 4 Hz repetition rate for the enamel; and from 250 mJ to 300 mJ with 4 Hz repetition rate for the dentine, and with 80 mJ with 6 Hz of repetition rate for laser conditioning. In the Er:YAG laser preparations no patient was anesthetized even when there were deeper cavities, and the maximum degree of pain ( which ranged from 0 to 10) was 4. In the control group with conventional high-speed drill two patients were anesthetized and the maximum degree of pain was 7. Restorations performed by conventional method of composite were equally satisfying both in caries groups of I and V class type and in the control group. The laser application in the operative dentistry office as a new method of diagnosis and dental preparations should be a good alternative to the use of the conventional dental drill. Nevertheless, dentistry practice has a lot to improve from technology progress, as well as new researches on laser dentistry are necessary in a long term. New types of lasers will come about and will increasingly improve the dental practice assistance and procedures quality. (author)

  5. Laser diagnostic and therapy of dental caries: the clinic point of view; Laser diagnostico e tratamento da carie dental: uma visao clinica

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Priscila Faria

    2001-07-01

    Dental caries's diagnosis is a major dentistry problem from the clinic point of view. The laser beam on the region of 655 nm induces the fluorescence of the compounds present in the hard tissue, quantifying differences between sound and carious enamel and dentine. Diagnodent (Kavo, Germany), showed to be effective regarding dental caries's diagnosis in the present research sampling. The Er:YAG laser (Kavo Key Laser 2, Germany) performed efficient cavity preparations in caries lesions of I and V class type, using up energies that ranged from 300 mJ to 350 mJ with 4 Hz repetition rate for the enamel; and from 250 mJ to 300 mJ with 4 Hz repetition rate for the dentine, and with 80 mJ with 6 Hz of repetition rate for laser conditioning. In the Er:YAG laser preparations no patient was anesthetized even when there were deeper cavities, and the maximum degree of pain ( which ranged from 0 to 10) was 4. In the control group with conventional high-speed drill two patients were anesthetized and the maximum degree of pain was 7. Restorations performed by conventional method of composite were equally satisfying both in caries groups of I and V class type and in the control group. The laser application in the operative dentistry office as a new method of diagnosis and dental preparations should be a good alternative to the use of the conventional dental drill. Nevertheless, dentistry practice has a lot to improve from technology progress, as well as new researches on laser dentistry are necessary in a long term. New types of lasers will come about and will increasingly improve the dental practice assistance and procedures quality. (author)

  6. Repetition or Reconfiguration

    DEFF Research Database (Denmark)

    Andersen, Kristina Vaarst

    , the cognitive quality of knowledge held by individual professionals is the key microfoundation for project level performance. This paper empirically tests effects of project participants with and without knowledge diversity for project level performance for projects aiming for varying degrees of repetition...... and reconfiguration. The results indicate that project performance benefits form contributions from individuals holding diverse knowledge only when projects aim for high differentiation levels. This positive association is not just moderated, it may even be reversed in the case of professionals participating in low...

  7. Visual attention to advertising : The impact of motivation and repetition

    NARCIS (Netherlands)

    Pieters, RGM; Rosbergen, E; Hartog, M; Corfman, KP; Lynch, JG

    1996-01-01

    Using eye-tracking data, we examine the impact of motivation and repetition on visual attention to advertisements differing in argument quality. Our analyses indicate that repetition leads to an overall decrease in the amount of attention. However, while at first high motivation subjects attend to

  8. Pull-production in repetitive remanufacturing

    Energy Technology Data Exchange (ETDEWEB)

    McCaskey, D.W. Jr.

    1992-09-01

    In the past, production activity control practices in most repetitive remanufacturing facilities resembled those used in intermittent production operations. These operations were characterized by large amounts of work-in-process (WIP), frequent work stoppages due to part shortages, excessive overtime, low product velocity, informal scheduling between dependent operations, low employee and management moral, and a lot of wasted time, material, labor, and space. Improvement in production activity control (PAC) methods for repetitive remanufactures has been hampered by uncertainty in: supply of incoming assets, configuration of assets, process times to refurbish assets, and yields in reclamation processes. collectively these uncertainties make shop floor operations seem uncontrollable. However, one United States Army depot has taken on the challenge. Through management supported, cross-functional teams, the Tooele Army Depot has designed and implemented pull-production systems for two of its major products, with several others to follow. This article presents a generalized version of Tooele`s pull-production system and highlights design characteristics which are specific to remanufacturing applications.

  9. Pull-production in repetitive remanufacturing

    Energy Technology Data Exchange (ETDEWEB)

    McCaskey, D.W. Jr.

    1992-09-01

    In the past, production activity control practices in most repetitive remanufacturing facilities resembled those used in intermittent production operations. These operations were characterized by large amounts of work-in-process (WIP), frequent work stoppages due to part shortages, excessive overtime, low product velocity, informal scheduling between dependent operations, low employee and management moral, and a lot of wasted time, material, labor, and space. Improvement in production activity control (PAC) methods for repetitive remanufactures has been hampered by uncertainty in: supply of incoming assets, configuration of assets, process times to refurbish assets, and yields in reclamation processes. collectively these uncertainties make shop floor operations seem uncontrollable. However, one United States Army depot has taken on the challenge. Through management supported, cross-functional teams, the Tooele Army Depot has designed and implemented pull-production systems for two of its major products, with several others to follow. This article presents a generalized version of Tooele's pull-production system and highlights design characteristics which are specific to remanufacturing applications.

  10. The effects of poliomyelitis on motor unit behavior during repetitive muscle actions: a case report.

    Science.gov (United States)

    Trevino, Michael A; Herda, Trent J; Cooper, Michael A

    2014-09-06

    Acute paralytic poliomyelitis is caused by the poliovirus and usually results in muscle atrophy and weakness occurring in the lower limbs. Indwelling electromyography has been used frequently to investigate the denervation and innervation characteristics of the affected muscle. Recently developed technology allows the decomposition of the raw surface electromyography signals into the firing instances of single motor units. There is limited information regarding this electromyographic decomposition in clinical populations. In addition, regardless of electromyographic methods, no study has examined muscle activation parameters during repetitive muscle actions in polio patients. Therefore, the purpose of this study was to examine the motor unit firing rates and electromyographic amplitude and center frequency of the vastus lateralis during 20 repetitive isometric muscle actions at 50% maximal voluntary contraction in healthy subjects and one patient that acquired acute paralytic poliomyelitis. One participant that acquired acute type III spinal poliomyelitis (Caucasian male, age = 29 yrs) at 3 months of age and three healthy participants (Caucasian females, age = 19.7 ± 2.1 yrs) participated in this study. The polio participant reported neuromuscular deficiencies as a result of disease in the hips, knees, buttocks, thighs, and lower legs. None of the healthy participants reported any current or ongoing neuromuscular diseases or musculoskeletal injuries. An acute bout of poliomyelitis altered motor unit behavior, such as, healthy participants displayed greater firing rates than the polio patient. The reduction in motor unit firing rates was likely a fatigue protecting mechanism since denervation via poliomyelitis results in a reduction of motorneurons. In addition, the concurrent changes in motor unit firing rates, electromyography amplitude and frequency for the polio participant would suggest that the entire motorneuron pool was utilized in each contraction unlike

  11. The Mark, the Thing, and the Object: On What Commands Repetition in Freud and Lacan.

    Science.gov (United States)

    Van de Vijver, Gertrudis; Bazan, Ariane; Detandt, Sandrine

    2017-01-01

    In Logique du Fantasme , Lacan argues that the compulsion to repeat does not obey the same discharge logic as homeostatic processes. Repetition installs a realm that is categorically different from the one related to homeostatic pleasure seeking, a properly subjective one, one in which the mark "stands for," "takes the place of," what we have ventured to call "an event," and what only in the movement of return, in what Lacan calls a "thinking of repetition," confirms and ever reconfirms this point of no return, which is also a qualitative cut and a structural loss. The kind of "standing for" Lacan intends here with the concept of repetition is certainly not something like an image or a faithful description. No, what Lacan wishes to stress is that this mark is situated at another level, at another place, it is " entstellt ," and as such, it is punctually impinging upon the bodily dynamics without rendering the event, without having an external meta-point of view, but cutting across registers according to a logics that is not the homeostatic memory logics. This paper elaborates on this distinction on the basis of a confrontation with what Freud says about the pleasure principle and its beyond in Beyond the Pleasure Principle , and also takes inspiration from Freud's Project for a Scientific Psychology. We argue that Lacan's theory of enjoyment takes up and generalizes what Freud was after in Beyond the Pleasure Principle with the Wiederholungszwang , and pushes Freud's thoughts to a more articulated point: to the point where a subject is considered to speak only when it has allowed the other, through discourse, to have impacted and cut into his bodily pleasure dynamics.

  12. Negative effects of item repetition on source memory

    OpenAIRE

    Kim, Kyungmi; Yi, Do-Joon; Raye, Carol L.; Johnson, Marcia K.

    2012-01-01

    In the present study, we explored how item repetition affects source memory for new item–feature associations (picture–location or picture–color). We presented line drawings varying numbers of times in Phase 1. In Phase 2, each drawing was presented once with a critical new feature. In Phase 3, we tested memory for the new source feature of each item from Phase 2. Experiments 1 and 2 demonstrated and replicated the negative effects of item repetition on incidental source memory. Prior item re...

  13. Functional dissociations in top-down control dependent neural repetition priming.

    NARCIS (Netherlands)

    Klaver, P.; Schnaidt, M.; Fell, J.; Ruhlmann, J.; Elger, C.E.; Fernandez, G.S.E.

    2007-01-01

    Little is known about the neural mechanisms underlying top-down control of repetition priming. Here, we use functional brain imaging to investigate these mechanisms. Study and repetition tasks used a natural/man-made forced choice task. In the study phase subjects were required to respond to either

  14. Autism and exergaming: effects on repetitive behaviors and cognition.

    Science.gov (United States)

    Anderson-Hanley, Cay; Tureck, Kimberly; Schneiderman, Robyn L

    2011-01-01

    Autism is a neurodevelopmental disorder that leads to impairment in social skills and delay in language development, and results in repetitive behaviors and restricted interests that impede academic and social involvement. Physical exercise has been shown to decrease repetitive behaviors in autistic children and improve cognitive function across the life-span. Exergaming combines physical and mental exercise simultaneously by linking physical activity movements to video game control and may yield better compliance with exercise. In this investigation, two pilot studies explored the potential behavioral and cognitive benefits of exergaming. In Pilot I, twelve children with autism spectrum disorders completed a control task and an acute bout of Dance Dance Revolution (DDR); in Pilot II, ten additional youths completed an acute bout of cyber cycling. Repetitive behaviors and executive function were measured before and after each activity. Repetitive behaviors significantly decreased, while performance on Digits Backwards improved following the exergaming conditions compared with the control condition. Additional research is needed to replicate these findings, and to explore the application of exergaming for the management of behavioral disturbance and to increase cognitive control in children on the autism spectrum.

  15. Understanding the relationship between repetition priming and mere exposure.

    Science.gov (United States)

    Butler, Laurie T; Berry, Dianne C

    2004-11-01

    Over the last two decades interest in implicit memory, most notably repetition priming, has grown considerably. During the same period, research has also focused on the mere exposure effect. Although the two areas have developed relatively independently, a number of studies has described the mere exposure effect as an example of implicit memory. Tacit in their comparisons is the assumption that the effect is more specifically a demonstration of repetition priming. Having noted that this assumption has attracted relatively little attention, this paper reviews current evidence and shows that it is by no means conclusive. Although some evidence is suggestive of a common underlying mechanism, even a modified repetition priming (perceptual fluency/attribution) framework cannot accommodate all of the differences between the two phenomena. Notwithstanding this, it seems likely that a version of this theoretical framework still offers the best hope of a comprehensive explanation for the mere exposure effect and its relationship to repetition priming. As such, the paper finishes by offering some initial guidance as to ways in which the perceptual fluency/attribution framework might be extended, as well as outlining important areas for future research.

  16. Repetitive transcranial magnetic stimulation of the superior frontal gyrus modulates craving for cigarettes.

    Science.gov (United States)

    Rose, Jed E; McClernon, F Joseph; Froeliger, Brett; Behm, Frédérique M; Preud'homme, Xavier; Krystal, Andrew D

    2011-10-15

    Previous functional magnetic resonance imaging studies have shown strong correlations between cue-elicited craving for cigarettes and activation of the superior frontal gyrus (SFG). Repetitive transcranial magnetic stimulation (rTMS) offers a noninvasive means to reversibly affect brain cortical activity, which can be applied to testing hypotheses about the causal role of SFG in modulating craving. Fifteen volunteer smokers were recruited to investigate the effects of rTMS on subjective responses to smoking versus neutral cues and to controlled presentations of cigarette smoke. On different days, participants were exposed to three conditions: 1) high-frequency (10 Hz) rTMS directed at the SFG; 2) low-frequency (1 Hz) rTMS directed at the SFG; and 3) low-frequency (1 Hz) rTMS directed at the motor cortex (control condition). Craving ratings in response to smoking versus neutral cues were differentially affected by the 10-Hz versus 1-Hz SFG condition. Craving after smoking cue presentations was elevated in the 10-Hz SFG condition, whereas craving after neutral cue presentations was reduced. Upon smoking in the 10-Hz SFG condition, ratings of immediate craving reduction as well as the intensity of interoceptive airway sensations were also attenuated. These results support the view that the SFG plays a role in modulating craving reactivity; moreover, the results suggest that the SFG plays a role in both excitatory and inhibitory influences on craving, consistent with prior research demonstrating the role of the prefrontal cortex in the elicitation as well as inhibition of drug-seeking behaviors. Copyright © 2011 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  17. An open-source LabVIEW application toolkit for phasic heart rate analysis in psychophysiological research.

    Science.gov (United States)

    Duley, Aaron R; Janelle, Christopher M; Coombes, Stephen A

    2004-11-01

    The cardiovascular system has been extensively measured in a variety of research and clinical domains. Despite technological and methodological advances in cardiovascular science, the analysis and evaluation of phasic changes in heart rate persists as a way to assess numerous psychological concomitants. Some researchers, however, have pointed to constraints on data analysis when evaluating cardiac activity indexed by heart rate or heart period. Thus, an off-line application toolkit for heart rate analysis is presented. The program, written with National Instruments' LabVIEW, incorporates a variety of tools for off-line extraction and analysis of heart rate data. Current methods and issues concerning heart rate analysis are highlighted, and how the toolkit provides a flexible environment to ameliorate common problems that typically lead to trial rejection is discussed. Source code for this program may be downloaded from the Psychonomic Society Web archive at www.psychonomic.org/archive/.

  18. Fragmented pictures revisited: long-term changes in repetition priming, relation to skill learning, and the role of cognitive resources.

    Science.gov (United States)

    Kennedy, Kristen M; Rodrigue, Karen M; Raz, Naftali

    2007-01-01

    Whereas age-related declines in declarative memory have been demonstrated in multiple cross-sectional and longitudinal studies, the effect of age on non-declarative manifestations of memory, such as repetition priming and perceptual skill learning, are less clear. The common assumption, based on cross-sectional studies, is that these processes are only mildly (if at all) affected by age. To investigate long-term changes in repetition priming and age-related differences in identification of fragmented pictures in a 5-year longitudinal design. Healthy adults (age 28-82 years) viewed drawings of objects presented in descending order of fragmentation. The identification threshold (IT) was the highest fragmentation level at which the object was correctly named. After a short interval, old pictures were presented again along with a set of similar but novel pictures. Five years later the participants repeated the experiment. At baseline and 5-year follow-up alike, one repeated exposure improved IT for old (priming) and new (skill acquisition) pictures. However, long-term retention of priming gains was observed only in young adults. Working memory explained a significant proportion of variance in within-occasion priming, long-term priming, and skill learning. Contrary to cross-sectional results, this longitudinal study suggests perceptual repetition priming is not an age-invariant phenomenon and advanced age and reduced availability of cognitive resources may contribute to its decline. Copyright 2007 S. Karger AG, Basel.

  19. Remote viewing system development in BNFL

    International Nuclear Information System (INIS)

    Case, D.R.; Garlick, D.R.; Crawford, G.; Montgomerie, J.

    1996-01-01

    The application of imaging systems to BNFL's plants is primarily provided by the Company's Engineering Group. Many systems have been developed for active service and several new developments are currently in an advanced stage of implementation. BNFL has acquired extensive experience of remote viewing from a series of projects undertaken for the Sellafield site in West Cumbria. Applications vary in size and complexity, from simple identification of bar-codes to more complex schemes for remotely storing UO 3 drums. Some are high speed and highly repetitive, whereas others are low speed but require high precision. In this paper the authors outline a selection of current applications. (UK)

  20. Remote viewing system development in BNFL

    International Nuclear Information System (INIS)

    Case, D.R.; Garlick, D.R.; Crawford, G.; Montgomerie, J.

    1996-01-01

    The application of imaging systems to BNFL's plants is primarily provided by the Company's Engineering Group. Many systems have been developed for active service and several new developments are currently in an advanced stage of implementation. BNFL has acquired extensive experience of remote viewing from a series of projects undertaken for the Sellafield site in West Cumbria. Applications vary in size and complexity, from simple identification of bar-codes to more complex schemes for remotely storing UO 3 drums. Some are high speed and highly repetitive, whereas others are low speed but require high precision. In this paper the authors shall outline a selection of current applications. (Author)

  1. New solid state opening switches for repetitive pulsed power technology

    Energy Technology Data Exchange (ETDEWEB)

    Lyubutin, S K; Mesyats, G A; Rukin, S N; Slovikovskii, B G; Turov, A M [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Electrophysics

    1997-12-31

    In 1991 the authors discovered a semiconductor opening switch (SOS) effect that occurs in p{sup +}-p-n-n{sup +} silicon structures at a current density of up to 60 kA/cm{sup 2}. This effect was used to develop high-power semiconductor opening switches in intermediate inductive storage circuits. The breaking power of the opening switches was as high as 5 GW, the interrupted current being up to 45 kA, reverse voltage up to 1 MV and the current interruption time between 10 and 60 ns. The opening switches were assembled from quantity-produced Russian-made rectifying diodes type SDL with hard recovery characteristic. On the basis of experimental and theoretical investigations of the SOS effect, new SOS diodes were designed and manufactured by the Electrophysical Institute. The paper gives basic parameters of the SOS diodes. The new diodes offer higher values of interrupted current and shorter times of current interruption together with a considerable increase in the energy switching efficiency. The new SOS diodes were used to develop repetitive all-solid-state pulsed generators with an output voltage of up to 250 kV, pulse repetition rate up to 5 kHz, and pulse duration between 10 and 30 ns. (author). 2 tabs., 3 figs., 4 refs.

  2. Risk factors for hand-wrist disorders in repetitive work

    DEFF Research Database (Denmark)

    Thomsen, J. F.; Mikkelsen, S.; Andersen, JH

    2007-01-01

    OBJECTIVES: To identify the risk of hand-wrist disorders related to repetitive movements, use of hand force and wrist position in repetitive monotonous work. METHODS: Using questionnaires and physical examinations, the prevalence and incidence of hand-wrist pain and possible extensor tendonitis...... (wrist pain and palpation tenderness) were determined in 3123 employees in 19 industrial settings. With the use of questionnaires and video recordings of homogenous work tasks number of wrist movements, hand force requirements and wrist position were analysed as risk factors for hand-wrist disorders......, controlling for potential personal and psychosocial confounders. All participants were re-examined three times during a follow-up period of three years. RESULTS: Force but not repetition and position was related to hand-wrist pain and possible tendonitis in the baseline analyses showing an exposure...

  3. Repetitive Bibliographical Information in Relational Databases.

    Science.gov (United States)

    Brooks, Terrence A.

    1988-01-01

    Proposes a solution to the problem of loading repetitive bibliographic information in a microcomputer-based relational database management system. The alternative design described is based on a representational redundancy design and normalization theory. (12 references) (Author/CLB)

  4. Versatile high-repetition-rate phase-locked chopper system for fast timing experiments in the vacuum ultraviolet and x-ray spectral region

    Energy Technology Data Exchange (ETDEWEB)

    Plogmaker, Stefan; Johansson, Erik M. J.; Rensmo, Haakan; Feifel, Raimund; Siegbahn, Hans [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Linusson, Per [Department of Physics, Stockholm University, AlbaNova University Center, SE-106 91 Stockholm (Sweden); Eland, John H. D. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ (United Kingdom); Baker, Neville [Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ (United Kingdom)

    2012-01-15

    A novel light chopper system for fast timing experiments in the vacuum-ultraviolet (VUV) and x-ray spectral region has been developed. It can be phase-locked and synchronized with a synchrotron radiation storage ring, accommodating repetition rates in the range of {approx}8 to {approx}120 kHz by choosing different sets of apertures and subharmonics of the ring frequency (MHz range). Also the opening time of the system can be varied from some nanoseconds to several microseconds to meet the needs of a broad range of applications. Adjusting these parameters, the device can be used either for the generation of single light pulses or pulse packages from a microwave driven, continuous He gas discharge lamp or from storage rings which are otherwise often considered as quasi-continuous light sources. This chopper can be utilized for many different kinds of experiments enabling, for example, unambiguous time-of-flight (TOF) multi-electron coincidence studies of atoms and molecules excited by a single light pulse as well as time-resolved visible laser pump x-ray probe electron spectroscopy of condensed matter in the valence and core level region.

  5. The repetition effect in building and construction works

    DEFF Research Database (Denmark)

    Gottlieb, Stefan Christoffer; Haugbølle, Kim

    are then applied on the Public Transport Authorities' main account structure of units and costs, and a method for assessing the possibilities of achieving effects of repetition for each account is described. Finally, the report summarises the core conditions necessary to take into consideration in relation......This report summarises the results from the work undertaken for the Public Transport Authority on the effect of learning and repetition in building and construction works. The results are applied by the Public Transport Authority in a new budgeting model, while the agency investigates...

  6. Comparison of concentric and eccentric bench press repetitions to failure.

    Science.gov (United States)

    Kelly, Stephen B; Brown, Lee E; Hooker, Steven P; Swan, Pamela D; Buman, Matthew P; Alvar, Brent A; Black, Laurie E

    2015-04-01

    Eccentric muscle actions (ECC) are characterized by muscle lengthening, despite actin-myosin crossbridge formation. Muscles acting eccentrically are capable of producing higher levels of force compared with muscles acting concentrically. The purpose of this study was to determine whether ECC bench press yields greater strength than concentric (CON) as determined by 1 repetition maximum (1RM). Additionally, a comparison was made examining differences in the number of repetitions to failure at different relative intensities of 1RM. Thirty healthy men (age = 24.63 ± 5.6 years) were tested for 1RM in CON and ECC bench press and the number of repetitions completed at 60, 70, 80, and 90% 1RM. For CON repetitions, the weight was mechanically lowered to the chest, and the participant pressed it up until the elbows were fully extended. The ECC bench press consisted of lowering a barbell from a fully extended elbow position to the chest in a continuous controlled manner for 3 seconds as determined by electronic metronome. Paired t-tests showed that ECC 1RM (115.99 ± 31.08 kg) was significantly (p ≤ 0.05) greater than CON 1RM (93.56 ± 26.56 kg), and the number of repetitions completed at 90% 1RM was significantly (p ≤ 0.05) greater in ECC (7.67 ± 3.24) as compared with CON (4.57 ± 2.21). There were no significant differences in number of completed repetitions during CON and ECC bench press at 60, 70, and 80% 1RM. These data indicate that ECC actions yield increased force capabilities (∼120%) as compared with CON in the bench press and may be less prone to fatigue, especially at higher intensities. These differences suggest a need to develop unique strategies for training eccentrically.

  7. Pulsed electron beam generation with fast repetitive double pulse system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  8. Spared behavioral repetition effects in Alzheimer's disease linked to an altered neural mechanism at posterior cortex.

    Science.gov (United States)

    Broster, Lucas S; Li, Juan; Wagner, Benjamin; Smith, Charles D; Jicha, Gregory A; Schmitt, Frederick A; Munro, Nancy; Haney, Ryan H; Jiang, Yang

    2018-02-20

    Individuals with dementia of the Alzheimer type (AD) classically show disproportionate impairment in measures of working memory, but repetition learning effects are relatively preserved. As AD affects brain regions implicated in both working memory and repetition effects, the neural basis of this discrepancy is poorly understood. We hypothesized that the posterior repetition effect could account for this discrepancy due to the milder effects of AD at visual cortex. Participants with early AD, amnestic mild cognitive impairment (MCI), and healthy controls performed a working memory task with superimposed repetition effects while electroencephalography was collected to identify possible neural mechanisms of preserved repetition effects. Participants with AD showed preserved behavioral repetition effects and a change in the posterior repetition effect. Visual cortex may play a role in maintained repetition effects in persons with early AD.

  9. Repetitive trauma and nerve compression.

    Science.gov (United States)

    Carragee, E J; Hentz, V R

    1988-01-01

    Repetitive movement of the upper extremity, whether recreational or occupational, may result in various neuropathies, the prototype of which is the median nerve neuropathic in the carpal canal. The pathophysiology of this process is incompletely understood but likely involves both mechanical and ischemic features. Experimentally increased pressures within the carpal canal produced reproducible progressive neuropathy. Changes in vibratory (threshold-type) sensibility appears to be more sensitive than two-point (innervation density-type) sensibility. The specific occupational etiologies of carpal neuropathy are obscured by methodologic and sociological difficulties, but clearly some occupations have high incidences of CTS. History and physical examination are usually sufficient for the diagnosis, but diagnostic assistance when required is available through electrophysiological testing, CT scanning, and possibly MRI. Each of these tests has limitations in both sensitivity and specificity. Treatment by usual conservative means should be combined with rest from possible provocative activities. Surgical release of the carpal canal is helpful in patients failing conservative therapy. Occupational modifications are important in both treatment and prevention of median neuropathy due to repetitive trauma.

  10. Repetitive Elements in Mycoplasma hyopneumoniae Transcriptional Regulation.

    Directory of Open Access Journals (Sweden)

    Amanda Malvessi Cattani

    Full Text Available Transcriptional regulation, a multiple-step process, is still poorly understood in the important pig pathogen Mycoplasma hyopneumoniae. Basic motifs like promoters and terminators have already been described, but no other cis-regulatory elements have been found. DNA repeat sequences have been shown to be an interesting potential source of cis-regulatory elements. In this work, a genome-wide search for tandem and palindromic repetitive elements was performed in the intergenic regions of all coding sequences from M. hyopneumoniae strain 7448. Computational analysis demonstrated the presence of 144 tandem repeats and 1,171 palindromic elements. The DNA repeat sequences were distributed within the 5' upstream regions of 86% of transcriptional units of M. hyopneumoniae strain 7448. Comparative analysis between distinct repetitive sequences found in related mycoplasma genomes demonstrated different percentages of conservation among pathogenic and nonpathogenic strains. qPCR assays revealed differential expression among genes showing variable numbers of repetitive elements. In addition, repeats found in 206 genes already described to be differentially regulated under different culture conditions of M. hyopneumoniae strain 232 showed almost 80% conservation in relation to M. hyopneumoniae strain 7448 repeats. Altogether, these findings suggest a potential regulatory role of tandem and palindromic DNA repeats in the M. hyopneumoniae transcriptional profile.

  11. Repetitive Elements in Mycoplasma hyopneumoniae Transcriptional Regulation.

    Science.gov (United States)

    Cattani, Amanda Malvessi; Siqueira, Franciele Maboni; Guedes, Rafael Lucas Muniz; Schrank, Irene Silveira

    2016-01-01

    Transcriptional regulation, a multiple-step process, is still poorly understood in the important pig pathogen Mycoplasma hyopneumoniae. Basic motifs like promoters and terminators have already been described, but no other cis-regulatory elements have been found. DNA repeat sequences have been shown to be an interesting potential source of cis-regulatory elements. In this work, a genome-wide search for tandem and palindromic repetitive elements was performed in the intergenic regions of all coding sequences from M. hyopneumoniae strain 7448. Computational analysis demonstrated the presence of 144 tandem repeats and 1,171 palindromic elements. The DNA repeat sequences were distributed within the 5' upstream regions of 86% of transcriptional units of M. hyopneumoniae strain 7448. Comparative analysis between distinct repetitive sequences found in related mycoplasma genomes demonstrated different percentages of conservation among pathogenic and nonpathogenic strains. qPCR assays revealed differential expression among genes showing variable numbers of repetitive elements. In addition, repeats found in 206 genes already described to be differentially regulated under different culture conditions of M. hyopneumoniae strain 232 showed almost 80% conservation in relation to M. hyopneumoniae strain 7448 repeats. Altogether, these findings suggest a potential regulatory role of tandem and palindromic DNA repeats in the M. hyopneumoniae transcriptional profile.

  12. Gyromagnetic nonlinear transmission line generator of high voltage pulses modulated at 4 GHz frequency with 1000 Hz pulse repetition rate

    International Nuclear Information System (INIS)

    Ulmasculov, M R; Sharypov, K A; Shunailov, S A; Shpak, V G; Yalandin, M I; Pedos, M S; Rukin, S N

    2017-01-01

    Results of testing of a generator based on a solid-state drive and the parallel gyromagnetic nonlinear transmission lines with external bias are presented. Stable rf-modulated high-voltage nanosecond pulses were shaped in each of the four channels in 1 s packets with 1000 Hz repetition frequencies. Pulse amplitude reaches -175 kV, at a modulation depth of rf-oscillations to 50 % and the effective frequency ∼4 GHz. (paper)

  13. Tropical cyclone turbulent mixing as observed by autonomous oceanic profilers with the high repetition rate

    International Nuclear Information System (INIS)

    Baranowski, D B; Malinowski, S P; Flatau, P J

    2011-01-01

    Changes in the ocean mixed layer caused by passage of two consecutive typhoons in the Western Pacific are presented. Ocean profiles were measured by a unique Argo float sampling the upper ocean in high repetition cycle with a period of about one day. It is shown that the typhoon passage coincides with cooling of the mixed layer and variations of its salinity. Independent data from satellite measurements of surface winds were used to set-up an and idealized numerical simulation of mixed layer evolution. Results, compared to Argo profiles, confirm known effect that cooling is a result of increased entrainment from the thermocline due to enhancement of turbulence in the upper ocean by the wind stress. Observed pattern of salinity changes in the mixed layer suggest important role of typhoon precipitation. Fast changes of the mixed layer in course of typhoon passage show that fast profiling (at least once a day) is crucial to study response of the upper ocean to tropical cyclone.

  14. Chromosome mapping of repetitive DNAs in sergeant major fishes (Abudefdufinae, Pomacentridae): a general view on the chromosomal conservatism of the genus.

    Science.gov (United States)

    Getlekha, Nuntaporn; Cioffi, Marcelo de Bello; Yano, Cassia Fernanda; Maneechot, Nuntiya; Bertollo, Luiz Antonio Carlos; Supiwong, Weerayuth; Tanomtong, Alongklod; Molina, Wagner Franco

    2016-10-01

    Species of the Abudefduf genus (sergeant-majors) are widely distributed in the Indian, Pacific and Atlantic oceans, with large schools inhabiting rocky coastal regions and coral reefs. This genus consists of twenty recognized species are of generalist habit, showing typical characteristics of colonizers. Some populations maintain gene flow between large oceanic areas, a condition that may influence their cytogenetic features. A number of species have been shown to be invaders and able to hybridize with local species. However, cytogenetic data in this genus are restricted to few species. In this way, the present study includes the chromosomal investigation, using conventional (Giemsa staining, Ag-NOR and C-banding) and molecular (in situ mapping of six different repetitive DNA classes) approaches in four Abudefduf species from different oceanic regions (A. bengalensis and A. sexfasciatus from the Indo-Pacific, A. vaigiensis from the Indian and A. saxatilis from the Atlantic oceans, respectively), to investigate the evolutionary events associated with the chromosomal diversification in this group. All species share a similar karyotype (2n = 48; NF = 52), except A. sexfasciatus (2n = 48; NF = 50), which possesses a characteristic pericentric inversion in the NOR-bearing chromosomal pair. Mapping of repetitive sequences suggests a chromosomal conservatism in this genus. The high karyotypic similarity between allopatric species of Abudefduf may be related to the success of natural viable hybrids among species with recent secondary contact.

  15. Repetitive elements in parasitic protozoa

    Directory of Open Access Journals (Sweden)

    Clayton Christine

    2010-05-01

    Full Text Available Abstract A recent paper published in BMC Genomics suggests that retrotransposition may be active in the human gut parasite Entamoeba histolytica. This adds to our knowledge of the various types of repetitive elements in parasitic protists and the potential influence of such elements on pathogenicity. See research article http://www.biomedcentral.com/1471-2164/11/321

  16. The Mark, the Thing, and the Object: On What Commands Repetition in Freud and Lacan

    Directory of Open Access Journals (Sweden)

    Gertrudis Van de Vijver

    2017-12-01

    Full Text Available In Logique du Fantasme, Lacan argues that the compulsion to repeat does not obey the same discharge logic as homeostatic processes. Repetition installs a realm that is categorically different from the one related to homeostatic pleasure seeking, a properly subjective one, one in which the mark “stands for,” “takes the place of,” what we have ventured to call “an event,” and what only in the movement of return, in what Lacan calls a “thinking of repetition,” confirms and ever reconfirms this point of no return, which is also a qualitative cut and a structural loss. The kind of “standing for” Lacan intends here with the concept of repetition is certainly not something like an image or a faithful description. No, what Lacan wishes to stress is that this mark is situated at another level, at another place, it is “entstellt,” and as such, it is punctually impinging upon the bodily dynamics without rendering the event, without having an external meta-point of view, but cutting across registers according to a logics that is not the homeostatic memory logics. This paper elaborates on this distinction on the basis of a confrontation with what Freud says about the pleasure principle and its beyond in Beyond the Pleasure Principle, and also takes inspiration from Freud’s Project for a Scientific Psychology. We argue that Lacan’s theory of enjoyment takes up and generalizes what Freud was after in Beyond the Pleasure Principle with the Wiederholungszwang, and pushes Freud’s thoughts to a more articulated point: to the point where a subject is considered to speak only when it has allowed the other, through discourse, to have impacted and cut into his bodily pleasure dynamics.

  17. Oxotremorine treatment reduces repetitive behaviors in BTBR T+ tf/J mice

    Directory of Open Access Journals (Sweden)

    Dionisio A. Amodeo

    2014-08-01

    Full Text Available Repetitive behaviors with restricted interests is one of the core criteria for the diagnosis of autism spectrum disorder (ASD. Current pharmacotherapies that target the dopaminergic or serotonergic systems have limited effectiveness in treating repetitive behaviors. Previous research has demonstrated that administration of muscarinic cholinergic receptor (mAChR antagonists can exacerbate motor stereotypies while mAChR agonists reduce stereotypies. The present study determined whether the mAChR agonist, oxotremorine affected repetitive behaviors in the BTBR T+ tf/J (BTBR mouse model of autism. To test the effects of oxotremorine on repetitive behaviors, marble burying and grooming behavior were measured in BTBR mice and compared to that in C57BL/6J (B6 mice. The effects of oxotremorine on locomotor activity was also measured. Thirty minutes before each test, mice received an intraperitoneal injection of saline, 0.001 mg or 0.01 mg of oxotremorine methiodide. Saline- treated BTBR mice exhibited increased marble burying and self-grooming behavior compared to that of saline-treated B6 mice. Oxotremorine significantly reduced marble burying and self-grooming behavior in BTBR mice, but had no significant effect in B6 mice. In addition, oxotremorine did not affect locomotor activity in BTBR mice, but significantly reduced locomotor activity in B6 mice at the 0.01 mg dose. These findings demonstrate that activation of mAChRs reduces repetitive behavior in the BTBR mouse and suggest that treatment with a mAChR agonist may be effective in reducing repetitive behaviors in ASD.

  18. The influence of stachydrine hydrochloride on the reperfusion model of mice with repetitive cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Mingsan Miao

    2017-03-01

    Full Text Available To study the influence of stachydrine hydrochloride on the inflammatory cytokines and tissue morphology of the re-perfusion model of mice with repetitive cerebral ischemia and probe into the protection mechanism of stachydrine hydrochloride for cerebral ischemia reperfusion impairment. Build a repetitive cerebral ischemia reperfusion model by first blocking the common carotid artery on both sides for 10 min, then resuming perfusion for 10 min and then blocking the common carotid artery on both sides again for 10 min. Before the operation, all the mice in the Nimodipine group, and the big, medium and small stachydrine hydrochloride dose groups were given corresponding gastric perfusion, the mice in the sham operation group and the modeled groups were at the same time given 0.5% sodium carboxymethyl cellulose for gastric perfusion of the same volume. The medicine was fed daily for 7 consecutive days. The model was built 1 h after the last feed and the perfusion continued for 24 h after the operation. Then the death rate of the mice was calculated. The mouse brains were taken out to test the ICAM-1 level and the TNF-α level, and the serum was taken out to test the NSE level and the MPO level. The tissue morphology changes were also observed. All the repetitive cerebral ischemia reperfusion models were successfully duplicated. The stachydrine hydrochloride in all the dose groups significantly reduced the death rates of big and small mice, reduced the level of ICAM-1 and the level of TNF-α in the brain tissues and the NSE level and the MPO level in the serum, significantly alleviating the pathological impairment in the hippocampus. Stachydrine hydrochloride can significantly reduce the death rate of mice, improve the pathological changes in the hippocampus, inhibit inflammatory reactions after ischemia, thus reducing the re-perfusion impairment after cerebral ischemia.

  19. Optimality based repetitive controller design for track-following servo system of optical disk drives.

    Science.gov (United States)

    Chen, Wentao; Zhang, Weidong

    2009-10-01

    In an optical disk drive servo system, to attenuate the external periodic disturbances induced by inevitable disk eccentricity, repetitive control has been used successfully. The performance of a repetitive controller greatly depends on the bandwidth of the low-pass filter included in the repetitive controller. However, owing to the plant uncertainty and system stability, it is difficult to maximize the bandwidth of the low-pass filter. In this paper, we propose an optimality based repetitive controller design method for the track-following servo system with norm-bounded uncertainties. By embedding a lead compensator in the repetitive controller, both the system gain at periodic signal's harmonics and the bandwidth of the low-pass filter are greatly increased. The optimal values of the repetitive controller's parameters are obtained by solving two optimization problems. Simulation and experimental results are provided to illustrate the effectiveness of the proposed method.

  20. Repetitive Treatment with Diluted Bee Venom Attenuates the Induction of Below-Level Neuropathic Pain Behaviors in a Rat Spinal Cord Injury Model.

    Science.gov (United States)

    Kang, Suk-Yun; Roh, Dae-Hyun; Choi, Jung-Wan; Ryu, Yeonhee; Lee, Jang-Hern

    2015-07-10

    The administration of diluted bee venom (DBV) into an acupuncture point has been utilized traditionally in Eastern medicine to treat chronic pain. We demonstrated previously that DBV has a potent anti-nociceptive efficacy in several rodent pain models. The present study was designed to examine the potential anti-nociceptive effect of repetitive DBV treatment in the development of below-level neuropathic pain in spinal cord injury (SCI) rats. DBV was applied into the Joksamli acupoint during the induction and maintenance phase following thoracic 13 (T13) spinal hemisection. We examined the effect of repetitive DBV stimulation on SCI-induced bilateral pain behaviors, glia expression and motor function recovery. Repetitive DBV stimulation during the induction period, but not the maintenance, suppressed pain behavior in the ipsilateral hind paw. Moreover, SCI-induced increase in spinal glia expression was also suppressed by repetitive DBV treatment in the ipsilateral dorsal spinal cord. Finally, DBV injection facilitated motor function recovery as indicated by the Basso-Beattie-Bresnahan rating score. These results indicate that the repetitive application of DBV during the induction phase not only decreased neuropathic pain behavior and glia expression, but also enhanced locomotor functional recovery after SCI. This study suggests that DBV acupuncture can be a potential clinical therapy for SCI management.

  1. Second Language Word Learning through Repetition and Imitation: Functional Networks as a Function of Learning Phase and Language Distance.

    Science.gov (United States)

    Ghazi-Saidi, Ladan; Ansaldo, Ana Ines

    2017-01-01

    Introduction and Aim : Repetition and imitation are among the oldest second language (L2) teaching approaches and are frequently used in the context of L2 learning and language therapy, despite some heavy criticism. Current neuroimaging techniques allow the neural mechanisms underlying repetition and imitation to be examined. This fMRI study examines the influence of verbal repetition and imitation on network configuration. Integration changes within and between the cognitive control and language networks were studied, in a pair of linguistically close languages (Spanish and French), and compared to our previous work on a distant language pair (Ghazi-Saidi et al., 2013). Methods : Twelve healthy native Spanish-speaking (L1) adults, and 12 healthy native Persian-speaking adults learned 130 new French (L2) words, through a computerized audiovisual repetition and imitation program. The program presented colored photos of objects. Participants were instructed to look at each photo and pronounce its name as closely as possible to the native template (imitate). Repetition was encouraged as many times as necessary to learn the object's name; phonological cues were provided if necessary. Participants practiced for 15 min, over 30 days, and were tested while naming the same items during fMRI scanning, at week 1 (shallow learning phase) and week 4 (consolidation phase) of training. To compare this set of data with our previous work on Persian speakers, a similar data analysis plan including accuracy rates (AR), response times (RT), and functional integration values for the language and cognitive control network at each measure point was included, with further L1-L2 direct comparisons across the two populations. Results and Discussion : The evidence shows that learning L2 words through repetition induces neuroplasticity at the network level. Specifically, L2 word learners showed increased network integration after 3 weeks of training, with both close and distant language

  2. Combined effect of repetitive work and cold on muscle function and fatigue.

    Science.gov (United States)

    Oksa, Juha; Ducharme, Michel B; Rintamäki, Hannu

    2002-01-01

    This study compared the effect of repetitive work in thermoneutral and cold conditions on forearm muscle electromyogram (EMG) and fatigue. We hypothesize that cold and repetitive work together cause higher EMG activity and fatigue than repetitive work only, thus creating a higher risk for overuse injuries. Eight men performed six 20-min work bouts at 25 degrees C (W-25) and at 5 degrees C while exposed to systemic (C-5) and local cooling (LC-5). The work was wrist flexion-extension exercise at 10% maximal voluntary contraction. The EMG activity of the forearm flexors and extensors was higher during C-5 (31 and 30%, respectively) and LC-5 (25 and 28%, respectively) than during W-25 (P forearm flexors at the end of W-25 was 15%. The corresponding values at the end of C-5 and LC-5 were 37% (P < 0.05 in relation to W-25) and 20%, respectively. Thus repetitive work in the cold causes higher EMG activity and fatigue than repetitive work in thermoneutral conditions.

  3. Electrophysiological Repetition Effects in Persons with Mild Cognitive Impairment depend upon Working Memory Demand.

    Science.gov (United States)

    Broster, Lucas S; Jenkins, Shonna L; Holmes, Sarah D; Edwards, Matthew G; Jicha, Gregory A; Jiang, Yang

    2018-05-07

    Forms of implicit memory, including repetition effects, are preserved relative to explicit memory in clinical Alzheimer's disease. Consequently, cognitive interventions for persons with Alzheimer's disease have been developed that leverage this fact. However, despite the clinical robustness of behavioral repetition effects, altered neural mechanisms of repetition effects are studied as biomarkers of both clinical Alzheimer's disease and pre-morbid Alzheimer's changes in the brain. We hypothesized that the clinical preservation of behavioral repetition effects results in part from concurrent operation of discrete memory systems. We developed two experiments that included probes of emotional repetition effects differing in that one included an embedded working memory task. We found that neural repetition effects manifested in patients with amnestic mild cognitive impairment, the earliest form of clinical Alzheimer's disease, during emotional working memory tasks, but they did not manifest during the task that lacked the embedded working memory manipulation. Specifically, the working memory task evoked neural repetition effects in the P600 time-window, but the same neural mechanism was only minimally implicated in the task without a working memory component. We also found that group differences in behavioral repetition effects were smaller in the experiment with a working memory task. We suggest that cross-domain cognitive challenge can expose "defunct" neural capabilities of individuals with amnestic mild cognitive impairment. Copyright © 2018. Published by Elsevier Ltd.

  4. Terahertz repetition frequencies from harmonic mode-locked monolithic compound-cavity laser diodes

    International Nuclear Information System (INIS)

    Yanson, D. A.; Street, M. W.; McDougall, S. D.; Thayne, I. G.; Marsh, J. H.; Avrutin, E. A.

    2001-01-01

    Compound-cavity laser diodes are mode locked at a harmonic of the fundamental round-trip frequency to achieve repetition rates of up to 2.1 THz. The devices are fabricated from GaAs/AlGaAs material at a wavelength of 860 nm and incorporate two gain sections with an etched slot reflector between them, and a saturable absorber section. Autocorrelation studies are used to investigate device behavior for different reflector types and reflectivity. These lasers may find applications in terahertz imaging, medicine, ultrafast optical links, and atmospheric sensing. [copyright] 2001 American Institute of Physics

  5. Illusory sensation of movement induced by repetitive transcranial magnetic stimulation

    DEFF Research Database (Denmark)

    Christensen, Mark Schram; Lundbye-Jensen, Jesper; Grey, Michael James

    2010-01-01

    Human movement sense relies on both somatosensory feedback and on knowledge of the motor commands used to produce the movement. We have induced a movement illusion using repetitive transcranial magnetic stimulation over primary motor cortex and dorsal premotor cortex in the absence of limb movement...... and its associated somatosensory feedback. Afferent and efferent neural signalling was abolished in the arm with ischemic nerve block, and in the leg with spinal nerve block. Movement sensation was assessed following trains of high-frequency repetitive transcranial magnetic stimulation applied over...... premotor cortex stimulation was less affected by sensory and motor deprivation than was primary motor cortex stimulation. We propose that repetitive transcranial magnetic stimulation over dorsal premotor cortex produces a corollary discharge that is perceived as movement....

  6. Physiological responses to four hours of low-level repetitive work

    DEFF Research Database (Denmark)

    Garde, A Helene; Hansen, Åse Marie; Jensen, Bente R

    2003-01-01

    OBJECTIVES: The study investigated physiological responses to 4 hours of standardized low-level repetitive work. It was hypothesized that accumulative effects not observed after 1 hour could be found after 4 hours of repetitive work. METHODS: Ten healthy women performed intermittent (5 seconds + 5...... muscle activity during a mental reference task with low exerted force indicated attention-related muscle activity. Finally, it was indicated that repetitive work including high demands for attention is performed at the expense of the precision of the exerted force....... seconds) handgrip contractions at 10% of the maximal voluntary contraction combined with mental demands for concentration and attention. Muscle activity in the working forearm muscles, cardiovascular responses, and concentrations of biomarkers in biological fluids were recorded along with exerted force...

  7. Role & Impact of Interest Rate in Jordan’ Economy from Points of View of Banking Managers

    Directory of Open Access Journals (Sweden)

    REEM SAHER alaraj

    2017-05-01

    Full Text Available The research aimed at investigating the role, impact and determinants of interest rate in Jordanian economy from view points of banking managers in Jordan. The methodology is descriptive and analytical using mean, standard deviation, t-test and percentages as statistical tools. The study concluded that the role of interest rate in Jordanian monetary policy is restricted by two factors: pegging JD with US$ which limits the effective role of interest rate in Jordanian monetary policy and the dual banking system of traditional and Islamic banks where Islamic banks do not deal with Interest rate. Raising interest rate in Jordan caused higher cost of credit for companies, less competitiveness of exports, less liquidity in the economy, higher profit margin for banks, higher exchange rate of JD and higher inflation. Nevertheless, lowering interest rate in Jordan caused lower cost of borrowing, higher liquidity, better competitiveness of exports and more credit facilities by banks but inflation was much lower. Moreover, the study concluded the determinants of interest rate in Jordan are money supply, demand for money, inflation and economic conditions. In order to have an effective role for interest rate in monetary policy, the researcher recommends pegging JD to a basket of currencies.

  8. GPI-repetitive control for linear systems with parameter uncertainty / variation

    Directory of Open Access Journals (Sweden)

    John A. Cortés-Romero

    2015-01-01

    Full Text Available Robust repetitive control problems for uncertain linear systems have been considered by different approaches. This article proposes the use of Repetitive Control and Generalized Proportional Integral (GPI Control in a complementary fashion. The conditioning and coupling of these techniques has been done in a time discrete context. Repetitive control is a control technique, based on the internal model principle, which yields perfect asymptotic tracking and rejection of periodic signals. On the other hand, GPI control is established as a robust linear control system design technique that is able to reject structured time polynomial additive perturbation, in particular, parameter uncertainty that can be locally approximated by time polynomial signal. GPI control provides a suitable stability and robustness conditions for the proper Repetitive Control operation. A stability analysis is presented under the frequency response framework using plant samples for different parameter uncertainty conditions. We carry out some comparative stability analysis with other complementary control approaches that has been effective for this kind of task, enhancing a better robustness and an improved performance for the GPI case. Illustrative simulation examples are presented which validate the proposed approach.

  9. One repetition maximum bench press performance: a new approach for its evaluation in inexperienced males and females: a pilot study.

    Science.gov (United States)

    Bianco, Antonino; Filingeri, Davide; Paoli, Antonio; Palma, Antonio

    2015-04-01

    The aim of this study was to evaluate a new method to perform the one repetition maximum (1RM) bench press test, by combining previously validated predictive and practical procedures. Eight young male and 7 females participants, with no previous experience of resistance training, performed a first set of repetitions to fatigue (RTF) with a workload corresponding to ⅓ of their body mass (BM) for a maximum of 25 repetitions. Following a 5-min recovery period, a second set of RTF was performed with a workload corresponding to ½ of participants' BM. The number of repetitions performed in this set was then used to predict the workload to be used for the 1RM bench press test using Mayhew's equation. Oxygen consumption, heart rate and blood lactate were monitored before, during and after each 1RM attempt. A significant effect of gender was found on the maximum number of repetitions achieved during the RTF set performed with ½ of participants' BM (males: 25.0 ± 6.3; females: 11.0x± 10.6; t = 6.2; p bench press test. We conclude that, by combining previously validated predictive equations with practical procedures (i.e. using a fraction of participants' BM to determine the workload for an RTF set), the new method we tested appeared safe, accurate (particularly in females) and time-effective in the practical evaluation of 1RM performance in inexperienced individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. About microlensing optical depth and rates for free-floating planets towards the Kepler's field of view

    International Nuclear Information System (INIS)

    Hafizi, M; Hamolli, L

    2012-01-01

    In this work we examine the possibility of observing microlensing events in the Kepler space observatory field of view, caused by brown dwarfs or free-floating planets. We calculate the optical depth towards the field of view of the Kepler satellite and the rate of these events based on latest results about mass distribution of astrophysical objects from brown dwarf down to Earth mass order. With the current data, the probability of such events is insignificant, due to the small number of stars observed by this instrument compared to other experiments devoted to the microlensing method. Nevertheless, this probability may increase significantly in the case of a higher presence of free-floating planets, whose number is poorly defined so far.

  11. Exploration of verbal repetition in people with dementia using an online symptom-tracking tool.

    Science.gov (United States)

    Reeve, Emily; Molin, Pierre; Hui, Amaris; Rockwood, Kenneth

    2017-06-01

    Online tools can be used by people with dementia and their caregivers to self-identify and track troubling symptoms, such as verbal repetition. We aimed to explore verbal repetition behaviors in people with dementia. Participants were recruited via an online resource for people with dementia and their caregivers. Respondents were instructed to complete information about symptoms that are most important to them for tracking over time. In this cross-sectional study, we analyzed data pertaining to individuals with dementia who had at least three symptoms selected for tracking. Of the 3,573 participants who began a user profile, 1,707 fulfilled criteria for analysis. Verbal repetition was identified as a treatment target in 807 respondents (47.3%). Verbal repetition was more frequent in individuals with mild dementia compared to those with moderate and severe dementia (57.2% vs. 36.0% and 39.9%, p < 0.01) and in those with Alzheimer's disease versus other dementias (65.2% vs. 29.7%, p < 0.001). Repetitive questioning was the most frequent type of verbal repetition (90.5% of individuals with verbal repetition). Verbal repetition was most strongly associated with difficulties operating gadgets/appliances (OR 3.65, 95%CI: 2.82-4.72), lack of interest and/or initiative (3.52: 2.84-4.36), misplacing or losing objects (3.25: 2.64-4.01), and lack of attention and/or concentration (2.62: 2.12-3.26). Verbal repetition is a common symptom in people at all stages of dementia but is most commonly targeted for monitoring and treatment effects in its mild stage. Much research is required to further elucidate the underlying mechanisms and the effect of different treatment strategies.

  12. Quantifying repetitive speech in autism spectrum disorders and language impairment.

    Science.gov (United States)

    van Santen, Jan P H; Sproat, Richard W; Hill, Alison Presmanes

    2013-10-01

    We report on an automatic technique for quantifying two types of repetitive speech: repetitions of what the child says him/herself (self-repeats) and of what is uttered by an interlocutor (echolalia). We apply this technique to a sample of 111 children between the ages of four and eight: 42 typically developing children (TD), 19 children with specific language impairment (SLI), 25 children with autism spectrum disorders (ASD) plus language impairment (ALI), and 25 children with ASD with normal, non-impaired language (ALN). The results indicate robust differences in echolalia between the TD and ASD groups as a whole (ALN + ALI), and between TD and ALN children. There were no significant differences between ALI and SLI children for echolalia or self-repetitions. The results confirm previous findings that children with ASD repeat the language of others more than other populations of children. On the other hand, self-repetition does not appear to be significantly more frequent in ASD, nor does it matter whether the child's echolalia occurred within one (immediate) or two turns (near-immediate) of the adult's original utterance. Furthermore, non-significant differences between ALN and SLI, between TD and SLI, and between ALI and TD are suggestive that echolalia may not be specific to ALN or to ASD in general. One important innovation of this work is an objective fully automatic technique for assessing the amount of repetition in a transcript of a child's utterances. © 2013 International Society for Autism Research, Wiley Periodicals, Inc.

  13. A Biochemist's View of Ecosystem Rates and their Response to Changing Temperature

    Science.gov (United States)

    Arcus, V. L.

    2017-12-01

    Enzyme kinetics lie at the heart of biochemistry and the Michaelis-Menten equation that defines the relationship between substrate and rate is over 100 years old. About 80 years ago Eyring and Polyani formulated Transistion State Theory (TST) which describes the temperature-dependence of chemical reaction rates and the precise relationship between activation energy and the rate. TST provided a robust theoretical foundation for the Arrhenius equation and together, these equations are the foundation equations for the biochemist. Can these equations provide any insights into rates at larger scales, such as organism growth rates and those rates that interest ecosystem scientists (e.g. heterotrophic respiration, gross primary production)? Let us begin by considering a microbial cell. Microbial growth (i.e. cell division) requires the coordinated kinetics of thousands of enzymes including DNA/RNA polymerases, ribosomes, biosynthetic enzymes - all under a regime of highly complex regulatory effects. There is no a priori reason to expect that Michaelis-Menten kinetics and TST will adequately describe this vastly complex process. Indeed, Lloyd and Taylor showed 23 years ago that soil respiration is not well described by the Arrhenius function. More recently, Heskel and colleagues showed that leaf respiration is also not well described by the Arrhenius function. It is the same case for rates of photosynthesis. Despite this failure of the basic equations of biochemistry to map to biological rates at greater scales, what insights can biochemistry provide to ecosystem science? As nearly all of biological metabolism is mediated through enzyme kinetics, I will begin with the Michaelis-Menten equation under regimes of low and high substrate concentrations. This simplified view can provide surprising insights into processes at larger scales. I will also consider the relationship between the activation energy and the reaction rate. Many, many ecosystem-rate papers focus on the

  14. Repetitive Behavior in Rubinstein-Taybi Syndrome: Parallels with Autism Spectrum Phenomenology

    Science.gov (United States)

    Waite, Jane; Moss, Joanna; Beck, Sarah R.; Richards, Caroline; Nelson, Lisa; Arron, Kate; Burbidge, Cheryl; Berg, Katy; Oliver, Chris

    2015-01-01

    Syndrome specific repetitive behavior profiles have been described previously. A detailed profile is absent for Rubinstein-Taybi syndrome (RTS). The Repetitive Behaviour Questionnaire and Social Communication Questionnaire were completed for children and adults with RTS (N = 87), Fragile-X (N = 196) and Down (N = 132) syndromes, and individuals…

  15. Effects of pulse-to-pulse residual species on discharges in repetitively pulsed discharges through packed bed reactors

    Science.gov (United States)

    Kruszelnicki, Juliusz; Engeling, Kenneth W.; Foster, John E.; Kushner, Mark J.

    2016-09-01

    Atmospheric pressure dielectric barrier discharges (DBDs) sustained in packed bed reactors (PBRs) are being investigated for conversion of toxic and waste gases, and CO2 removal. These discharges are repetitively pulsed having varying flow rates and internal geometries, which results in species from the prior pulse still being in the discharge zone at the time the following discharge pulse occurs. A non-negligible residual plasma density remains, which effectively acts as preionization. This residual charge changes the discharge properties of subsequent pulses, and may impact important PBR properties such as chemical selectivity. Similarly, the residual neutral reactive species produced during earlier pulses will impact the reaction rates on subsequent pulses. We report on results of a computational investigation of a 2D PBR using the plasma hydrodynamics simulator nonPDPSIM. Results will be discussed for air flowing though an array of dielectric rods at atmospheric pressure. The effects of inter-pulse residual species on PBR discharges will be quantified. Means of controlling the presence of residual species in the reactor through gas flow rate, pulse repetition, pulse width and geometry will be described. Comparisons will be made to experiments. Work supported by US DOE Office of Fusion Energy Science and the National Science Foundation.

  16. Preliminary design of a 150 kJ repetitive plasma focus for the production of 18-F

    Science.gov (United States)

    Sumini, Marco; Mostacci, Domiziano; Rocchi, Federico; Frignani, Michele; Tartari, Agostino; Angeli, Ergisto; Galaverni, Dario; Coli, Ugo; Ascione, Bernardino; Cucchi, Giorgio

    2006-06-01

    Experiments in the past five years have demonstrated production of short-lived radioisotopes with a Plasma Focus device, using the so-termed Endogenous Mode. So far radioisotope activities of only a few microcuries have been obtained from single discharges in small scale Plasma Focus machines (capacitor bank energies of approximately 7 kJ). It is expected that higher activities could be obtained with larger bank energies, operating at high pulse repetition rates, e.g. 1 Hz. However, many scientific and technological issues must be addressed for a high-energy Plasma Focus device to run at one pulse per second. Aim of this paper is to present preliminary results pertaining to the plasma, electrical, fluid-dynamical, thermal, material and mechanical design of a 150 kJ Plasma Focus, capable of a repetition rate of 1 Hz, that will be operated at 30 kV with a 350 μF capacitor bank and a maximum total current of 1.5 MA. This device will be used to breed 18-F for the synthesis of drugs used in positron-emission medical examinations, such as FDG for PET.

  17. Preliminary design of a 150 kJ repetitive plasma focus for the production of 18-F

    International Nuclear Information System (INIS)

    Sumini, Marco; Mostacci, Domiziano; Rocchi, Federico; Frignani, Michele; Tartari, Agostino; Angeli, Ergisto; Galaverni, Dario; Coli, Ugo; Ascione, Bernardino; Cucchi, Giorgio

    2006-01-01

    Experiments in the past five years have demonstrated production of short-lived radioisotopes with a Plasma Focus device, using the so-termed Endogenous Mode. So far radioisotope activities of only a few microcuries have been obtained from single discharges in small scale Plasma Focus machines (capacitor bank energies of approximately 7 kJ). It is expected that higher activities could be obtained with larger bank energies, operating at high pulse repetition rates, e.g. 1 Hz. However, many scientific and technological issues must be addressed for a high-energy Plasma Focus device to run at one pulse per second. Aim of this paper is to present preliminary results pertaining to the plasma, electrical, fluid-dynamical, thermal, material and mechanical design of a 150 kJ Plasma Focus, capable of a repetition rate of 1 Hz, that will be operated at 30 kV with a 350 μF capacitor bank and a maximum total current of 1.5 MA. This device will be used to breed 18-F for the synthesis of drugs used in positron-emission medical examinations, such as FDG for PET

  18. Repetitive, small-bore two-stage light gas gun

    International Nuclear Information System (INIS)

    Combs, S.K.; Foust, C.R.; Fehling, D.T.; Gouge, M.J.; Milora, S.L.

    1991-01-01

    A repetitive two-stage light gas gun for high-speed pellet injection has been developed at Oak Ridge National Laboratory. In general, applications of the two-stage light gas gun have been limited to only single shots, with a finite time (at least minutes) needed for recovery and preparation for the next shot. The new device overcomes problems associated with repetitive operation, including rapidly evacuating the propellant gases, reloading the gun breech with a new projectile, returning the piston to its initial position, and refilling the first- and second-stage gas volumes to the appropriate pressure levels. In addition, some components are subjected to and must survive severe operating conditions, which include rapid cycling to high pressures and temperatures (up to thousands of bars and thousands of kelvins) and significant mechanical shocks. Small plastic projectiles (4-mm nominal size) and helium gas have been used in the prototype device, which was equipped with a 1-m-long pump tube and a 1-m-long gun barrel, to demonstrate repetitive operation (up to 1 Hz) at relatively high pellet velocities (up to 3000 m/s). The equipment is described, and experimental results are presented. 124 refs., 6 figs., 5 tabs

  19. Effects of slow repetitive transcranial magnetic stimulation in patients with corticobasal syndrome.

    Science.gov (United States)

    Civardi, Carlo; Pisano, Fabrizio; Delconte, Carmen; Collini, Alessandra; Monaco, Francesco

    2015-06-01

    Corticobasal syndrome is characterized by asymmetric cortical sensorimotor dysfunction and parkinsonism; an altered cortical excitability has been reported. We explored with transcranial magnetic stimulation the motor cortical excitability in corticobasal syndrome, and the effects of slow repetitive transcranial magnetic stimulation. With transcranial magnetic stimulation, we studied two corticobasal syndrome patients. We determined bilaterally from the first dorsal interosseous muscle: relaxed threshold, and contralateral and ipsilateral silent period. We also evaluated the contralateral silent period after active/sham slow repetitive transcranial magnetic stimulation on the most affected side. At T0 the silent period was bilaterally short. On the most affected side, active slow repetitive transcranial magnetic stimulation induced a short lasting prolongation of the contralateral silent period. In corticobasal syndrome, transcranial magnetic stimulation showed a reduction cortical inhibitory phenomenon potentially reversed transiently by slow repetitive transcranial magnetic stimulation.

  20. Dissociating mere exposure and repetition priming as a function of word type.

    Science.gov (United States)

    Butler, Laurie T; Berry, Dianne C; Helman, Shaun

    2004-07-01

    The mere exposure effect is defined as enhanced attitude toward a stimulus that has been repeatedly exposed. Repetition priming is defined as facilitated processing of a previously exposed stimulus. We conducted a direct comparison between the two phenomena to test the assumption that the mere exposure effect represents an example of repetition priming. In two experiments, having studied a set of words or nonwords, participants were given a repetition priming task (perceptual identification) or one of two mere exposure (affective liking or preference judgment) tasks. Repetition priming was obtained for both words and nonwords, but only nonwords produced a mere exposure effect. This demonstrates a key boundary for observing the mere exposure effect, one not readily accommodated by a perceptual representation systems (Tulving & Schacter, 1990) account, which assumes that both phenomena should show some sensitivity to nonwords and words.

  1. PCR amplification of repetitive sequences as a possible approach in relative species quantification

    DEFF Research Database (Denmark)

    Ballin, Nicolai Zederkopff; Vogensen, Finn Kvist; Karlsson, Anders H

    2012-01-01

    Abstract Both relative and absolute quantifications are possible in species quantification when single copy genomic DNA is used. However, amplification of single copy genomic DNA does not allow a limit of detection as low as one obtained from amplification of repetitive sequences. Amplification...... of repetitive sequences is therefore frequently used in absolute quantification but problems occur in relative quantification as the number of repetitive sequences is unknown. A promising approach was developed where data from amplification of repetitive sequences were used in relative quantification of species...... to relatively quantify the amount of chicken DNA in a binary mixture of chicken DNA and pig DNA. However, the designed PCR primers lack the specificity required for regulatory species control....

  2. Independent and additive repetition priming of motion direction and color in visual search.

    Science.gov (United States)

    Kristjánsson, Arni

    2009-03-01

    Priming of visual search for Gabor patch stimuli, varying in color and local drift direction, was investigated. The task relevance of each feature varied between the different experimental conditions compared. When the target defining dimension was color, a large effect of color repetition was seen as well as a smaller effect of the repetition of motion direction. The opposite priming pattern was seen when motion direction defined the target--the effect of motion direction repetition was this time larger than for color repetition. Finally, when neither was task relevant, and the target defining dimension was the spatial frequency of the Gabor patch, priming was seen for repetition of both color and motion direction, but the effects were smaller than in the previous two conditions. These results show that features do not necessarily have to be task relevant for priming to occur. There is little interaction between priming following repetition of color and motion, these two features show independent and additive priming effects, most likely reflecting that the two features are processed at separate processing sites in the nervous system, consistent with previous findings from neuropsychology & neurophysiology. The implications of the findings for theoretical accounts of priming in visual search are discussed.

  3. Repetitive transcranial magnetic stimulation in cervical dystonia: effect of site and repetition in a randomized pilot trial.

    Directory of Open Access Journals (Sweden)

    Sarah Pirio Richardson

    Full Text Available Dystonia is characterized by abnormal posturing due to sustained muscle contraction, which leads to pain and significant disability. New therapeutic targets are needed in this disorder. The objective of this randomized, sham-controlled, blinded exploratory study is to identify a specific motor system target for non-invasive neuromodulation and to evaluate this target in terms of safety and tolerability in the cervical dystonia (CD population. Eight CD subjects were given 15-minute sessions of low-frequency (0.2 Hz repetitive transcranial magnetic stimulation (rTMS over the primary motor cortex (MC, dorsal premotor cortex (dPM, supplementary motor area (SMA, anterior cingulate cortex (ACC and a sham condition with each session separated by at least two days. The Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS score was rated in a blinded fashion immediately pre- and post-intervention. Secondary outcomes included physiology and tolerability ratings. The mean change in TWSTRS severity score by site was 0.25 ± 1.7 (ACC, -2.9 ± 3.4 (dPM, -3.0 ± 4.8 (MC, -0.5 ± 1.1 (SHAM, and -1.5 ± 3.2 (SMA with negative numbers indicating improvement in symptom control. TWSTRS scores decreased from Session 1 (15.1 ± 5.1 to Session 5 (11.0 ± 7.6. The treatment was tolerable and safe. Physiology data were acquired on 6 of 8 subjects and showed no change over time. These results suggest rTMS can modulate CD symptoms. Both dPM and MC are areas to be targeted in further rTMS studies. The improvement in TWSTRS scores over time with multiple rTMS sessions deserves further evaluation.

  4. Properties of Repetitive Long-Period Seismicity at Villarrica Volcano, Chile

    Science.gov (United States)

    Richardson, J.; Waite, G. P.; Palma, J.; Johnson, J. B.

    2011-12-01

    Villarrica Volcano, Chile hosts a persistent lava lake and is characterized by degassing and long-period seismicity. In order to better understand the relationship between outgassing and seismicity, we recorded broadband seismic and acoustic data along with high-rate SO2 emission data. We used both a densely-spaced linear array deployed on the northern flank of Villarrica, during the austral summer of 2011, and a wider aperture array of stations distributed around the volcano that was active in the austral summer of 2010. Both deployments consisted of three-component broadband stations and were augmented with broadband infrasound sensors. Of particular interests are repetitive, ~1 Hz seismic and coincident infrasound signals that occurred approximately every 2 minutes. Because these events are typically very low amplitude, we used a matched filter approach to identify them. We windowed several high-amplitude records of these events from broadband seismic stations near the vent. The record section of each event served as a template to compare with the entire dataset by cross-correlation. This approach identified ~20,000 nearly identical events during the ~7 day deployment of the linear array, which were otherwise difficult to identify in the raw records. Assuming that all of the events that we identified have identical source mechanisms and depths, we stack the large suite of events to produce low-noise records and particle motions at receivers farther than 5 km from the vent. We find that the records from stations near the edifice are dominated by tangential particle motion, suggesting the influence of near-field components. Correlation of these data with broadband acoustic data collected at the summit suggest that these repeatable seismic processes are linked to acoustic emissions, probably due to gas bubbles bursting at the magma free surface, as no eruptive products besides gas were being emitted by the volcano during the instrument deployment. The acoustic

  5. How Are Child Restricted and Repetitive Behaviors Associated with Caregiver Stress over Time? A Parallel Process Multilevel Growth Model

    Science.gov (United States)

    Harrop, Clare; McBee, Matthew; Boyd, Brian A.

    2016-01-01

    The impact of raising a child with autism spectrum disorder (ASD) is frequently accompanied by elevated caregiver stress. Examining the variables that predict these elevated rates will help us understand how caregiver stress is impacted by and impacts child behaviors. This study explored how restricted and repetitive behaviors (RRBs) contributed…

  6. Neurobehavioural Correlates of Abnormal Repetitive Behaviour

    Directory of Open Access Journals (Sweden)

    R. A. Ford

    1991-01-01

    Full Text Available Conditions in which echolalia and echopraxia occur are reviewed, followed by an attempt to elicit possible mechanisms of these phenomena. A brief description of stereotypical and perseverative behaviour and obsessional phenomena is given. It is suggested that abnormal repetitive behaviour may occur partly as a result of central dopaminergic dysfunction.

  7. Longer repetition duration increases muscle activation and blood lactate response in matched resistance training protocols

    Directory of Open Access Journals (Sweden)

    Hugo Cesar Martins-Costa

    2016-03-01

    Full Text Available Abstract This study analyzed the effect of different repetition durations on electromyographic and blood lactate responses of the bench press exercise. Fifteen recreationally trained male volunteers completed two training protocols, matched for intensity (% one-repetition maximum; 1RM, number of sets, number of repetitions, and rest intervals. One of the protocols was performed with a repetition duration of 4 s (2 s concentric: 2 s eccentric; 2:2 protocol, whereas the second protocol had a repetition duration of 6 s (2 s concentric: 4 s eccentric; 2:4 protocol. The results showed higher normalized integrated electromyography (pectoralis major and triceps brachii for the 2:4 protocol. Blood lactate concentration was also higher in the 2:4 protocol across all sets. These results show that adding 2 s to the eccentric action in matched training protocols increases muscle activation and blood lactate response, which reinforces the notion that increasing repetition duration is an alternative load progression in resistance training.

  8. Repetitive element transcripts are elevated in the brain of C9orf72 ALS/FTLD patients.

    Science.gov (United States)

    Prudencio, Mercedes; Gonzales, Patrick K; Cook, Casey N; Gendron, Tania F; Daughrity, Lillian M; Song, Yuping; Ebbert, Mark T W; van Blitterswijk, Marka; Zhang, Yong-Jie; Jansen-West, Karen; Baker, Matthew C; DeTure, Michael; Rademakers, Rosa; Boylan, Kevin B; Dickson, Dennis W; Petrucelli, Leonard; Link, Christopher D

    2017-09-01

    Significant transcriptome alterations are detected in the brain of patients with amyotrophic lateral sclerosis (ALS), including carriers of the C9orf72 repeat expansion and C9orf72-negative sporadic cases. Recently, the expression of repetitive element transcripts has been associated with toxicity and, while increased repetitive element expression has been observed in several neurodegenerative diseases, little is known about their contribution to ALS. To assess whether aberrant expression of repetitive element sequences are observed in ALS, we analysed RNA sequencing data from C9orf72-positive and sporadic ALS cases, as well as healthy controls. Transcripts from multiple classes and subclasses of repetitive elements (LINEs, endogenous retroviruses, DNA transposons, simple repeats, etc.) were significantly increased in the frontal cortex of C9orf72 ALS patients. A large collection of patient samples, representing both C9orf72 positive and negative ALS, ALS/FTLD, and FTLD cases, was used to validate the levels of several repetitive element transcripts. These analyses confirmed that repetitive element expression was significantly increased in C9orf72-positive compared to C9orf72-negative or control cases. While previous studies suggest an important link between TDP-43 and repetitive element biology, our data indicate that TDP-43 pathology alone is insufficient to account for the observed changes in repetitive elements in ALS/FTLD. Instead, we found that repetitive element expression positively correlated with RNA polymerase II activity in postmortem brain, and pharmacologic modulation of RNA polymerase II activity altered repetitive element expression in vitro. We conclude that increased RNA polymerase II activity in ALS/FTLD may lead to increased repetitive element transcript expression, a novel pathological feature of ALS/FTLD. © The Author 2017. Published by Oxford University Press.

  9. Nonword Repetition and Vocabulary Knowledge as Predictors of Children's Phonological and Semantic Word Learning.

    Science.gov (United States)

    Adlof, Suzanne M; Patten, Hannah

    2017-03-01

    This study examined the unique and shared variance that nonword repetition and vocabulary knowledge contribute to children's ability to learn new words. Multiple measures of word learning were used to assess recall and recognition of phonological and semantic information. Fifty children, with a mean age of 8 years (range 5-12 years), completed experimental assessments of word learning and norm-referenced assessments of receptive and expressive vocabulary knowledge and nonword repetition skills. Hierarchical multiple regression analyses examined the variance in word learning that was explained by vocabulary knowledge and nonword repetition after controlling for chronological age. Together with chronological age, nonword repetition and vocabulary knowledge explained up to 44% of the variance in children's word learning. Nonword repetition was the stronger predictor of phonological recall, phonological recognition, and semantic recognition, whereas vocabulary knowledge was the stronger predictor of verbal semantic recall. These findings extend the results of past studies indicating that both nonword repetition skill and existing vocabulary knowledge are important for new word learning, but the relative influence of each predictor depends on the way word learning is measured. Suggestions for further research involving typically developing children and children with language or reading impairments are discussed.

  10. High-speed repetitive pellet injector prototype for magnetic confinement fusion devices

    International Nuclear Information System (INIS)

    Frattolillo, A.; Gasparotto, M.; Migliori, S.; Angelone, G.; Baldarelli, M.; Scaramuzzi, F.; Ronci, G.; Reggiori, A.; Riva, G.; Carlevaro, R.; Daminelli, G.B.

    1992-01-01

    The design of a test facility aimed at demonstrating the feasibility of high-speed repetitive acceleration of solid D 2 pellets for fusion applications, developed in a collaboration between Oak Ridge National Laboratory and ENEA Frascati, is presented. The results of tests performed at the CNPM/CNR on the piston wear in a repetitively operating two-stage gun are also reported

  11. Widespread Chromatin Accessibility at Repetitive Elements Links Stem Cells with Human Cancer

    Directory of Open Access Journals (Sweden)

    Nicholas C. Gomez

    2016-11-01

    Full Text Available Chromatin regulation is critical for differentiation and disease. However, features linking the chromatin environment of stem cells with disease remain largely unknown. We explored chromatin accessibility in embryonic and multipotent stem cells and unexpectedly identified widespread chromatin accessibility at repetitive elements. Integrating genomic and biochemical approaches, we demonstrate that these sites of increased accessibility are associated with well-positioned nucleosomes marked by distinct histone modifications. Differentiation is accompanied by chromatin remodeling at repetitive elements associated with altered expression of genes in relevant developmental pathways. Remarkably, we found that the chromatin environment of Ewing sarcoma, a mesenchymally derived tumor, is shared with primary mesenchymal stem cells (MSCs. Accessibility at repetitive elements in MSCs offers a permissive environment that is exploited by the critical oncogene responsible for this cancer. Our data demonstrate that stem cells harbor a unique chromatin landscape characterized by accessibility at repetitive elements, a feature associated with differentiation and oncogenesis.

  12. Tactile Ranschburg effects: facilitation and inhibitory repetition effects analogous to verbal memory.

    Science.gov (United States)

    Roe, Daisy; Miles, Christopher; Johnson, Andrew J

    2017-07-01

    The present paper examines the effect of within-sequence item repetitions in tactile order memory. Employing an immediate serial recall procedure, participants reconstructed a six-item sequence tapped upon their fingers by moving those fingers in the order of original stimulation. In Experiment 1a, within-sequence repetition of an item separated by two-intervening items resulted in a significant reduction in recall accuracy for that repeated item (i.e., the Ranschburg effect). In Experiment 1b, within-sequence repetition of an adjacent item resulted in significant recall facilitation for that repeated item. These effects mirror those reported for verbal stimuli (e.g., Henson, 1998a . Item repetition in short-term memory: Ranschburg repeated. Journal of Experimental Psychology: Learning, Memory, and Cognition, 24(5), 1162-1181. doi:doi.org/10.1037/0278-7393.24.5.1162). These data are the first to demonstrate the Ranschburg effect with non-verbal stimuli and suggest further cross-modal similarities in order memory.

  13. Don't Throw out the Baby with the Bathwater: Verbal Repetition, Mnemonics, and Active Learning

    Science.gov (United States)

    Saber, Jane Lee; Johnson, Richard D.

    2008-01-01

    The effectiveness of using verbal repetition and first-letter acronyms to teach a common marketing framework was examined in two experiments. In Experiment 1, 345 undergraduate students were exposed to the framework using one of four conditions: control, verbal repetition, acronym, and verbal repetition plus acronym in a traditional learning…

  14. Macrophage and tumor cell responses to repetitive pulsed X-ray radiation

    Science.gov (United States)

    Buldakov, M. A.; Tretyakova, M. S.; Ryabov, V. B.; Klimov, I. A.; Kutenkov, O. P.; Kzhyshkowska, J.; Bol'shakov, M. A.; Rostov, V. V.; Cherdyntseva, N. V.

    2017-05-01

    To study a response of tumor cells and macrophages to the repetitive pulsed low-dose X-ray radiation. Methods. Tumor growth and lung metastasis of mice with an injected Lewis lung carcinoma were analysed, using C57Bl6. Monocytes were isolated from a human blood, using CD14+ magnetic beads. IL6, IL1-betta, and TNF-alpha were determined by ELISA. For macrophage phenotyping, a confocal microscopy was applied. “Sinus-150” was used for the generation of pulsed X-ray radiation (the absorbed dose was below 0.1 Gy, the pulse repetition frequency was 10 pulse/sec). The irradiation of mice by 0.1 Gy pulsed X-rays significantly inhibited the growth of primary tumor and reduced the number of metastatic colonies in the lung. Furthermore, the changes in macrophage phenotype and cytokine secretion were observed after repetitive pulsed X-ray radiation. Conclusion. Macrophages and tumor cells had a different response to a low-dose pulsed X-ray radiation. An activation of the immune system through changes of a macrophage phenotype can result in a significant antitumor effect of the low-dose repetitive pulsed X-ray radiation.

  15. Inducing repetitive action potential firing in neurons via synthesized photoresponsive nanoscale cellular prostheses.

    Science.gov (United States)

    Lu, Siyuan; Madhukar, Anupam

    2013-02-01

    Recently we reported an analysis that examined the potential of synthesized photovoltaic functional abiotic nanosystems (PVFANs) to modulate membrane potential and activate action potential firing in neurons. Here we extend the analysis to delineate the requirements on the electronic energy levels and the attendant photophysical properties of the PVFANs to induce repetitive action potential under continuous light, a capability essential for the proposed potential application of PVFANs as retinal cellular prostheses to compensate for loss of photoreceptors. We find that repetitive action potential firing demands two basic characteristics in the electronic response of the PVFANs: an exponential dependence of the PVFAN excited state decay rate on the membrane potential and a three-state system such that, following photon absorption, the electron decay from the excited state to the ground state is via intermediate state(s) whose lifetime is comparable to the refractory time following an action potential. In this study, the potential of synthetic photovoltaic functional abiotic nanosystems (PVFANs) is examined under continuous light to modulate membrane potential and activate action potential firing in neurons with the proposed potential application of PVFANs as retinal cellular prostheses. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Closed-cycle 1-kHz-pulse-repetition-frequency HF(DF) laser

    Science.gov (United States)

    Harris, Michael R.; Morris, A. V.; Gorton, Eric K.

    1998-05-01

    We describe the design and performance of a closed cycle, high pulse repetition frequency HF(DF) laser. A short duration, glow discharge is formed in a 10 SF6:1 H2(D2) gas mixture at a total pressure of approximately 110 torr. A pair of profiled electrodes define a 15 X 0.5 X 0.5 cm3 discharge volume through which gas flow is forced in the direction transverse to the optical axis. A centrifugal fan provides adequate gas flow to enable operation up to 3 kHz repetition frequency. The fan also passes the gas through a scrubber cell in which ground state HF(DF) is eliminated from the gas stream. An automated gas make-up system replenishes the spent fuel gases removed by the scrubber. Total gas admission is regulated by monitoring the system pressure, whilst the correct fuel balance is maintained through measurement of the discharge voltage. The HF(DF) generation rate is determined to be close to 5 X 1019 molecules per second per watt of laser output. Typical mean laser output powers of up to 3 watts can be delivered for extended periods of time. The primary limitation to life is found to be the discharge pre- ionization system. A distributed resistance corona pre- ionizer is shown to be advantageous when compared with an alternative arc array scheme.

  17. Theoretical repeatability assessment without repetitive measurements in gradient high-performance liquid chromatography.

    Science.gov (United States)

    Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki

    2016-07-08

    This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Storytelling and Repetitive Narratives for Design Empathy

    DEFF Research Database (Denmark)

    Fritsch, Jonas; Judice, Andrea; Soini, Katja

    2007-01-01

    study. In this paper, we show how we attained an empathic understanding through storytelling and aroused empathy to others using repetitive narratives in an experimental presentation bringing forth factual, reflective and experiential aspects of the user information. Taking as a starting point our...

  19. The algorithm for duration acceleration of repetitive projects considering the learning effect

    Science.gov (United States)

    Chen, Hongtao; Wang, Keke; Du, Yang; Wang, Liwan

    2018-03-01

    Repetitive project optimization problem is common in project scheduling. Repetitive Scheduling Method (RSM) has many irreplaceable advantages in the field of repetitive projects. As the same or similar work is repeated, the proficiency of workers will be correspondingly low to high, and workers will gain experience and improve the efficiency of operations. This is learning effect. Learning effect is one of the important factors affecting the optimization results in repetitive project scheduling. This paper analyzes the influence of the learning effect on the controlling path in RSM from two aspects: one is that the learning effect changes the controlling path, the other is that the learning effect doesn't change the controlling path. This paper proposes corresponding methods to accelerate duration for different types of critical activities and proposes the algorithm for duration acceleration based on the learning effect in RSM. And the paper chooses graphical method to identity activities' types and considers the impacts of the learning effect on duration. The method meets the requirement of duration while ensuring the lowest acceleration cost. A concrete bridge construction project is given to verify the effectiveness of the method. The results of this study will help project managers understand the impacts of the learning effect on repetitive projects, and use the learning effect to optimize project scheduling.

  20. Repetitive negative thinking and suicide: a burgeoning literature with need for further exploration.

    Science.gov (United States)

    Law, Keyne C; Tucker, Raymond P

    2017-08-24

    Extant research has found a significant overlap between various repetitive negative thinking (RNT) patterns, such as rumination and worry, across different affective disorders implicating that the process of repetitive negative thinking is likely trans-diagnostic. Furthermore, RNT patterns at the core of psychiatric disorders associated with suicide (e.g., rumination and worry) have been found to be associated with suicide even after accounting for the disorder. A synthesis of existing literature on repetitive negative thoughts suggest that following negative emotional experiences, RNTs may lead to a sense of entrapment and hopelessness that may contribute to the onset of suicidal ideation and then facilitate the transition from thinking about suicide to making a suicide attempt by increasing an individual's capability for suicide through repetitive exposure to violent thoughts and imagery associated with suicide. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. On the non-Poissonian repetition pattern of FRB121102

    Science.gov (United States)

    Oppermann, Niels; Yu, Hao-Ran; Pen, Ue-Li

    2018-04-01

    The Fast Radio Burst FRB121102 has been observed to repeat in an irregular fashion. Using published timing data of the observed bursts, we show that Poissonian statistics are not a good description of this random process. As an alternative, we suggest to describe the intervals between bursts with a Weibull distribution with a shape parameter smaller than one, which allows for the clustered nature of the bursts. We quantify the amount of clustering using the parameters of the Weibull distribution and discuss the consequences that it has for the detection probabilities of future observations and for the optimization of observing strategies. Allowing for this generalization, we find a mean repetition rate of r=5.7^{+3.0}_{-2.0} per day and index k=0.34^{+0.06}_{-0.05} for a correlation function ξ(t) = (t/t0)k - 1.

  2. Errors in nonword repetition: bridging short- and long-term memory.

    Science.gov (United States)

    Santos, F H; Bueno, O F A; Gathercole, S E

    2006-03-01

    According to the working memory model, the phonological loop is the component of working memory specialized in processing and manipulating limited amounts of speech-based information. The Children's Test of Nonword Repetition (CNRep) is a suitable measure of phonological short-term memory for English-speaking children, which was validated by the Brazilian Children's Test of Pseudoword Repetition (BCPR) as a Portuguese-language version. The objectives of the present study were: i) to investigate developmental aspects of the phonological memory processing by error analysis in the nonword repetition task, and ii) to examine phoneme (substitution, omission and addition) and order (migration) errors made in the BCPR by 180 normal Brazilian children of both sexes aged 4-10, from preschool to 4th grade. The dominant error was substitution [F(3,525) = 180.47; P long than in short items, was observed [F(3,519) = 108.36; P long-term memory contributes to holding memory trace. The findings were discussed in terms of distinctiveness, clustering and redintegration hypotheses.

  3. Repetitive control of an electrostatic microbridge actuator: theory and simulation

    International Nuclear Information System (INIS)

    Zhao, Haiyu; Rahn, Christopher D

    2010-01-01

    Electrostatic microactuators are used extensively in MEMS sensors, RF switches and microfluidic pumps. The high bandwidth operation required by these applications complicates the implementation of feedback controllers. This paper designs, proves stability and simulates a feedforward repetitive controller for an electrostatic microbridge. High residual stress creates tension in the microbridge that dominates bending stiffness so a pinned string model with uniform electrostatic force loading is used for model-based control. The control objective is to force the microbridge displacement to follow prescribed spatial and periodic time trajectories. Viscous damping ensures boundedness of the distributed transverse displacement in response to bounded inputs. The average displacement is measured by capacitive sensing and processed offline using a repetitive control algorithm that updates a high speed waveform generator's parameters. Simulations show that the performance depends on the amount of damping. With less than 1% damping in a representative microbridge structure, repetitive control reduces the midspan displacement overshoot by 83%

  4. Periventricular white matter abnormalities and restricted repetitive behavior in autism spectrum disorder

    Directory of Open Access Journals (Sweden)

    Karen Blackmon

    2016-01-01

    Full Text Available Malformations of cortical development are found at higher rates in autism spectrum disorder (ASD than in healthy controls on postmortem neuropathological evaluation but are more variably observed on visual review of in-vivo MRI brain scans. This may be due to the visually elusive nature of many malformations on MRI. Here, we utilize a quantitative approach to determine whether a volumetric measure of heterotopic gray matter in the white matter is elevated in people with ASD, relative to typically developing controls (TDC. Data from a primary sample of 48 children/young adults with ASD and 48 age-, and gender-matched TDCs, selected from the Autism Brain Imaging Data Exchange (ABIDE open-access database, were analyzed to compare groups on (1 blinded review of high-resolution T1-weighted research sequences; and (2 quantitative measurement of white matter hypointensity (WMH volume calculated from the same T1-weighted scans. Groupwise WMH volume comparisons were repeated in an independent, multi-site sample (80 ASD/80 TDC, also selected from ABIDE. Visual review resulted in equivalent proportions of imaging abnormalities in the ASD and TDC group. However, quantitative analysis revealed elevated periventricular and deep subcortical WMH volumes in ASD. This finding was replicated in the independent, multi-site sample. Periventricular WMH volume was not associated with age but was associated with greater restricted repetitive behaviors on both parent-reported and clinician-rated assessment inventories. Thus, findings demonstrate that periventricular WMH volume is elevated in ASD and associated with a higher degree of repetitive behaviors and restricted interests. Although the etiology of focal WMH clusters is unknown, the absence of age effects suggests that they may reflect a static anomaly.

  5. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Science.gov (United States)

    Baksht, E. Kh; Burachenko, A. G.; Lomaev, M. I.; Panchenko, A. N.; Tarasenko, V. F.

    2015-04-01

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ~4 ns and a rise time of ~2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 - 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr.

  6. Effects of Navigated Repetitive Transcranial Magnetic Stimulation After Stroke.

    Science.gov (United States)

    Chervyakov, Alexander V; Poydasheva, Alexandra G; Lyukmanov, Roman H; Suponeva, Natalia A; Chernikova, Ludmila A; Piradov, Michael A; Ustinova, Ksenia I

    2018-03-01

    The purpose of this study was to test the effects of navigated repetitive transcranial magnetic stimulation, delivered in different modes, on motor impairments and functional limitations after stroke. The study sample included 42 patients (58.5 ± 10.7 years; 26 males) who experienced a single unilateral stroke (1-12 months previously) in the area of the middle cerebral artery. Patients completed a course of conventional rehabilitation, together with 10 sessions of navigated repetitive transcranial magnetic stimulation or sham stimulation. Stimulation was scheduled five times a week over two consecutive weeks in an inpatient clinical setting. Patients were randomly assigned to one of four groups and received sham stimulation (n = 10), low-frequency (1-Hz) stimulation of the nonaffected hemisphere (n = 11), high-frequency (10-Hz) stimulation of the affected hemisphere (n = 13), or sequential combination of low- and high-frequency stimulations (n = 8). Participants were evaluated before and after stimulation with clinical tests, including the arm and hand section of the Fugl-Meyer Assessment Scale, modified Ashworth Scale of Muscle Spasticity, and Barthel Index of Activities of Daily Living. Participants in the three groups receiving navigated repetitive transcranial magnetic stimulation showed improvements in arm and hand functions on the Fugl-Meyer Stroke Assessment Scale. Ashworth Scale of Muscle Spasticity and Barthel Index scores were significantly reduced in groups receiving low- or high-frequency stimulation alone. Including navigated repetitive transcranial magnetic stimulation in a conventional rehabilitation program positively influenced motor and functional recovery in study participants, demonstrating the clinical potential of the method. The results of this study will be used for designing a large-scale clinical trial.

  7. The effect of changing from one to two views at incident (subsequent) screens in the NHS breast screening programme in England: impact on cancer detection and recall rates

    International Nuclear Information System (INIS)

    Blanks, R.G.; Bennett, R.L.; Patnick, J.; Cush, S.; Davison, C.; Moss, S.M.

    2005-01-01

    AIM: To assess the effect on cancer detection and recall rates of changing from one to two views for incident (subsequent) screens. METHODS: Controlled, comparative, observational study of programmes in NHS breast screening programme in England. Subjects: women aged 50-64 years were screened by the NHSBSP between 1 April 2001 and 31 March 2003. RESULTS: The effect of changing to two-view mammography was a 20% increase in overall incident screen cancer detection rate, with the biggest effect seen for small (<15 mm) invasive cancers. This increased detection rate was achieved with an 11% drop-in recall rate. CONCLUSION: The introduction of two-view mammography for incident screens has resulted in considerable improvements in overall NHS breast screening performance

  8. 3D reconstruction from multi-view VHR-satellite images in MicMac

    Science.gov (United States)

    Rupnik, Ewelina; Pierrot-Deseilligny, Marc; Delorme, Arthur

    2018-05-01

    This work addresses the generation of high quality digital surface models by fusing multiple depths maps calculated with the dense image matching method. The algorithm is adapted to very high resolution multi-view satellite images, and the main contributions of this work are in the multi-view fusion. The algorithm is insensitive to outliers, takes into account the matching quality indicators, handles non-correlated zones (e.g. occlusions), and is solved with a multi-directional dynamic programming approach. No geometric constraints (e.g. surface planarity) or auxiliary data in form of ground control points are required for its operation. Prior to the fusion procedures, the RPC geolocation parameters of all images are improved in a bundle block adjustment routine. The performance of the algorithm is evaluated on two VHR (Very High Resolution)-satellite image datasets (Pléiades, WorldView-3) revealing its good performance in reconstructing non-textured areas, repetitive patterns, and surface discontinuities.

  9. Ultra-high-resolution inelastic X-ray scattering at high-repetition-rate self-seeded X-ray free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chubar, Oleg [Brookhaven National Laboratory, Upton, NY 11973 (United States); Geloni, Gianluca [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Kocharyan, Vitali [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Madsen, Anders [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Saldin, Evgeni; Serkez, Svitozar [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Shvyd’ko, Yuri, E-mail: shvydko@aps.anl.gov [Argonne National Laboratory, Argonne, IL 60439 (United States); Sutter, John [Diamond Light Source Ltd, Didcot OX11 0DE (United Kingdom)

    2016-02-12

    This article explores novel opportunities for ultra-high-resolution inelastic X-ray scattering (IXS) at high-repetition-rate self-seeded XFELs. These next-generation light sources are promising a more than three orders of magnitude increase in average spectral flux compared with what is possible with storage-ring-based radiation sources. In combination with the advanced IXS spectrometer described here, this may become a real game-changer for ultra-high-resolution X-ray spectroscopies, and hence for the studies of dynamics in condensed matter systems. Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm{sup −1} spectral and momentum-transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm{sup −1} are required to close the gap in energy–momentum space between high- and low-frequency probes. It is shown that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a 100-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than what is possible with storage-ring-based radiation sources. Wave-optics calculations show that about 7 × 10{sup 12} photons s{sup −1} in a 90 µeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.

  10. [Identification of a repetitive sequence element for DNA fingerprinting in Phytophthora sojae].

    Science.gov (United States)

    Yin, Lihua; Wang, Qinhu; Ning, Feng; Zhu, Xiaoying; Zuo, Yuhu; Shan, Weixing

    2010-04-01

    Establishment of DNA fingerprinting in Phytophthora sojae and an analysis of genetic relationship of Heilongjiang and Xinjiang populations. Bioinformatics tools were used to search repetitive sequences in P. sojae and Southern blot analysis was employed for DNA fingerprinting analysis of P. sojae populations from Heilongjiang and Xinjiang using the identified repetitive sequence. A moderately repetitive sequence was identified and designated as PS1227. Southern blot analysis indicated 34 distinct bands ranging in size from 1.5 kb-23 kb, of which 21 were polymorphic among 49 isolates examined. Analysis of single-zoospore progenies showed that the PS1227 fingerprint pattern was mitotically stable. DNA fingerprinting showed that the P. sojae isolates HP4002, SY6 and GJ0105 of Heilongjiang are genetically identical to DW303, 71228 and 71222 of Xinjiang, respectively. A moderately repetitive sequence designated PS1227 which will be useful for epidemiology and population biology studies of P. sojae was obtained, and a PS1227-based DNA fingerprinting analysis provided molecular evidence that P. sojae in Xinjiang was likely introduced from Heilongjiang.

  11. Topic Repetition in Conversations on Different Days as a Sign of Dementia.

    Science.gov (United States)

    Shinkawa, Kaoru; Yamada, Yasunori

    2018-01-01

    Detecting early signs of dementia in everyday situations becomes more and more important in a rapidly aging society. Language dysfunctions are recognized as the prominent signs of dementia. Previous computational studies characterized these language dysfunctions by using acoustic and linguistic features for detecting dementia. However, they mainly investigated language dysfunctions collected from patients during neuropsychological tests. Language dysfunctions observed during regular conversations in everyday situations received little attention. One of the dysfunctions associated with dementia which is frequently observed in regular conversations is the repetition of a topic on different days. In this study, we propose a feature to characterize topic repetition in conversations on different days. We used conversational data obtained from a daily monitoring service of eight elderly people, two of whom had dementia. Through the analysis of topic extraction with latent Dirichlet allocation, we found that the frequency of topic repetition was significantly higher in people with dementia than in the control group. The results suggest that our proposed feature for identifying topic repetition in regular conversations on different days might be used for detecting dementia.

  12. Product placement in video games: The effect of brand familiarity and repetition on consumers´ memory

    OpenAIRE

    Martí Parreño, José; Bermejo Berros, Jesús; Aldás Manzano, Joaquín

    2017-01-01

    Product placement in video games is gaining momentum as a means to target audiences in an indirect and engaging way. This research uses a 2 (high repetition vs low repetition) x 2 (high brand familiarity vs low brand familiarity) factorial design to test the effects of repetition and brand familiarity on consumers’ memory for brands placed in video games. Results suggest that consumers recall better familiar than unfamiliar brands placed in the video game and repetition increases recall for f...

  13. Priming With 1-Hz Repetitive Transcranial Magnetic Stimulation Over Contralesional Leg Motor Cortex Does Not Increase the Rate of Regaining Ambulation Within 3 Months of Stroke: A Randomized Controlled Trial.

    Science.gov (United States)

    Huang, Ying-Zu; Lin, Li-Fong; Chang, Kwang-Hwa; Hu, Chaur-Jong; Liou, Tsan-Hon; Lin, Yen-Nung

    2018-05-01

    The potential benefits of repetitive transcranial magnetic stimulation (rTMS), applied either alone or as a combination treatment, on recovery of lower limbs after stroke have been insufficiently studied. The aim of the study was to evaluate the effect of priming with 1-Hz repetitive transcranial magnetic stimulation over contralesional leg motor area with a double-cone coil before physical therapy on regaining ambulation. Thirty-eight subacute stroke patients with significant leg disabilities were randomly assigned into the experimental group or control group to receive a 15-min real or sham 1-Hz repetitive transcranial magnetic stimulation, respectively, over the contralesional motor cortex representing the quadriceps muscle followed by 45-min physical therapy for 15 sessions for 3 wks. Functional measures, motor evoked potentials, and quality of life were assessed. There was no significant difference between experimental group and control group regarding the recovery in ambulation, balance, motor functions, and activity of daily living. No significant difference was found in other functional measures and the quality of life. Only the control group displayed significantly increased cortical excitability of the contralesional hemisphere after the intervention. The present study found that insufficient evidence that contralesional priming with 1-Hz repetitive transcranial magnetic stimulation improves ambulatory and other motor functions among patients with a severe leg dysfunction in subacute stroke.

  14. Genome-wide survey of repetitive DNA elements in the button mushroom Agaricus bisporus

    NARCIS (Netherlands)

    Foulongne-Oriol, M.; Murat, C.; Castanera, R.; Ramírez, L.; Sonnenberg, A.S.M.

    2013-01-01

    Repetitive DNA elements are ubiquitous constituents of eukaryotic genomes. The biological roles of these repetitive elements, supposed to impact genome organization and evolution, are not completely elucidated yet. The availability of whole genome sequence offers the opportunity to draw a picture of

  15. Reducing Repetitive Speech: Effects of Strategy Instruction.

    Science.gov (United States)

    Dipipi, Caroline M.; Jitendra, Asha K.; Miller, Judith A.

    2001-01-01

    This article describes an intervention with an 18-year-old young woman with mild mental retardation and a seizure disorder, which focused on her repetitive echolalic verbalizations. The intervention included time delay, differential reinforcement of other behaviors, and self-monitoring. Overall, the intervention was successful in facilitating…

  16. Comprehension priming as rational expectation for repetition: Evidence from syntactic processing.

    Science.gov (United States)

    Myslín, Mark; Levy, Roger

    2016-02-01

    Why do comprehenders process repeated stimuli more rapidly than novel stimuli? We consider an adaptive explanation for why such facilitation may be beneficial: priming is a consequence of expectation for repetition due to rational adaptation to the environment. If occurrences of a stimulus cluster in time, given one occurrence it is rational to expect a second occurrence closely following. Leveraging such knowledge may be particularly useful in online processing of language, where pervasive clustering may help comprehenders negotiate the considerable challenge of continual expectation update at multiple levels of linguistic structure and environmental variability. We test this account in the domain of structural priming in syntax, making use of the sentential complement-direct object (SC-DO) ambiguity. We first show that sentences containing SC continuations cluster in natural language, motivating an expectation for repetition of this structure. Second, we show that comprehenders are indeed sensitive to the syntactic clustering properties of their current environment. In a series of between-groups self-paced reading studies, we find that participants who are exposed to clusters of SC sentences subsequently process repetitions of SC structure more rapidly than participants who are exposed to the same number of SCs spaced in time, and attribute the difference to the learned degree of expectation for repetition. We model this behavior through Bayesian belief update, showing that (the optimal degree of) sensitivity to clustering properties of syntactic structures is indeed learnable through experience. Comprehension priming effects are thus consistent with rational expectation for repetition based on adaptation to the linguistic environment. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Pulse repetition frequency effects in a high average power x-ray preionized excimer laser

    International Nuclear Information System (INIS)

    Fontaine, B.; Forestier, B.; Delaporte, P.; Canarelli, P.

    1989-01-01

    Experimental study of waves damping in a high repetition rate excimer laser is undertaken. Excitation of laser active medium in a subsonic loop is achieved by means of a classical discharge, through transfer capacitors. The discharge stability is controlled by a wire ion plasma (w.i.p.) X-rays gun. The strong acoustic waves induced by the active medium excitation may lead to a decrease, at high PRF, of the energy per pulse. First results of the influence of a damping of induced density perturbations between two successive pulses are presented

  18. Repetitive plasma opening switch for powerful high-voltage pulse generators

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Zakatov, L.P.; Nitishinskii, M.S.; Ushakov, A.G.

    1998-01-01

    Results are presented of experimental studies of plasma opening switches that serve to sharpen the pulses of inductive microsecond high-voltage pulse generators. It is demonstrated that repetitive plasma opening switches can be used to create super-powerful generators operating in a quasi-continuous regime. An erosion switching mechanism and the problem of magnetic insulation in repetitive switches are considered. Achieving super-high peak power in plasma switches makes it possible to develop new types of high-power generators of electron beams and X radiation. Possible implementations and the efficiency of these generators are discussed

  19. Repetitive Transcranial Magnetic Stimulation: a Novel Approach for Treating Oropharyngeal Dysphagia

    OpenAIRE

    Michou, Emilia; Raginis-Zborowska, Alicja; Watanabe, Masahiro; Lodhi, Taha; Hamdy, Shaheen

    2016-01-01

    In recent years, repetitive transcranial magnetic stimulation, a technique used to produce human central neurostimulation, has attracted increased interest and been applied experimentally in the treatment of dysphagia. This review presents a synopsis of the current research for the application of repetitive transcranial magnetic stimulation (rTMS) on dysphagia. Here, we review the mechanisms underlying the effects of rTMS and the results from studies on both healthy volunteers and dysphagic p...

  20. Repetitive pulse accelerator technology for light ion inertial confinement fusion

    International Nuclear Information System (INIS)

    Buttram, M.T.

    1985-01-01

    Successful ignition of an inertial confinement fusion (ICF) pellet is calculated to require that several megajoules of energy be deposited in the pellet's centimeter-sized shell within 10 ns. This implies a driver power of several hundreds of terawatts and power density around 100 TW/cm 2 . The Sandia ICF approach is to deposit the energy with beams of 30 MV lithium ions. The first accelerator capable of producing these beams (PBFA II, 100 TW) will be used to study beam formation and target physics on a single pulse basis. To utilize this technology for power production, repetitive pulsing at rates that may be as high as 10 Hz will be required. This paper will overview the technologies being studied for a repetitively pulsed ICF accelerator. As presently conceived, power is supplied by rotating machinery providing 16 MJ in 1 ms. The generator output is transformed to 3 MV, then switched into a pulse compression system using laser triggered spark gaps. These must be synchronized to about 1 ns. Pulse compression is performed with saturable inductor switches, the output being 40 ns, 1.5 MV pulses. These are transformed to 30 MV in a self-magnetically insulated cavity adder structure. Space charge limited ion beams are drawn from anode plasmas with electron counter streaming being magnetically inhibited. The ions are ballistically focused into the entrances of guiding discharge channels for transport to the pellet. The status of component development from the prime power to the ion source will be reviewed

  1. Repetitive Behaviours and Restricted Interests in Individuals with Down Syndrome—One Way of Managing Their World?

    Directory of Open Access Journals (Sweden)

    Sheila Glenn

    2017-06-01

    Full Text Available This paper argues that the repetitive behaviour and restrictive interests (RBRI displayed by individuals with Down syndrome have mostly positive functions. However, as research has developed from interests in Obsessional Compulsive Disorder or Autistic Spectrum Disorder, unfortunately a view has arisen that RBRI in individuals with Down syndrome are also likely to be pathological. This is particularly the case in adults. The paper reviews: (a measures employed and the perspectives that have been used; (b the development in typically developing individuals, those with Down syndrome, and those with other conditions associated with intellectual disability; (c positive and possible negative effects of RBRI; and (d the need for more research. The conclusion is that, for their level of development, RBRI are helpful for most individuals with Down syndrome.

  2. Transduction of Repetitive Mechanical Stimuli by Piezo1 and Piezo2 Ion Channels

    Directory of Open Access Journals (Sweden)

    Amanda H. Lewis

    2017-06-01

    Full Text Available Several cell types experience repetitive mechanical stimuli, including vein endothelial cells during pulsating blood flow, inner ear hair cells upon sound exposure, and skin cells and their innervating dorsal root ganglion (DRG neurons when sweeping across a textured surface or touching a vibrating object. While mechanosensitive Piezo ion channels have been clearly implicated in sensing static touch, their roles in transducing repetitive stimulations are less clear. Here, we perform electrophysiological recordings of heterologously expressed mouse Piezo1 and Piezo2 responding to repetitive mechanical stimulations. We find that both channels function as pronounced frequency filters whose transduction efficiencies vary with stimulus frequency, waveform, and duration. We then use numerical simulations and human disease-related point mutations to demonstrate that channel inactivation is the molecular mechanism underlying frequency filtering and further show that frequency filtering is conserved in rapidly adapting mouse DRG neurons. Our results give insight into the potential contributions of Piezos in transducing repetitive mechanical stimuli.

  3. Additive effects of repetition and predictability during comprehension: evidence from event-related potentials.

    Directory of Open Access Journals (Sweden)

    Wing-Yee Chow

    Full Text Available Previous research has shown that neural responses to words during sentence comprehension are sensitive to both lexical repetition and a word's predictability in context. While previous research has often contrasted the effects of these variables (e.g. by looking at cases in which word repetition violates sentence-level constraints, little is known about how they work in tandem. In the current study we examine how recent exposure to a word and its predictability in context combine to impact lexical semantic processing. We devise a novel paradigm that combines reading comprehension with a recognition memory task, allowing for an orthogonal manipulation of a word's predictability and its repetition status. Using event-related brain potentials (ERPs, we show that word repetition and predictability have qualitatively similar and additive effects on the N400 amplitude. We propose that prior exposure to a word and predictability impact lexical semantic processing in an additive and independent fashion.

  4. Outcomes in spasticity after repetitive transcranial magnetic and transcranial direct current stimulations

    OpenAIRE

    Gunduz, Aysegul; Kumru, Hatice; Pascual-Leone, Alvaro

    2014-01-01

    Non-invasive brain stimulations mainly consist of repetitive transcranial magnetic stimulation and transcranial direct current stimulation. Repetitive transcranial magnetic stimulation exhibits satisfactory outcomes in improving multiple sclerosis, stroke, spinal cord injury and cerebral palsy-induced spasticity. By contrast, transcranial direct current stimulation has only been studied in post-stroke spasticity. To better validate the efficacy of non-invasive brain stimulations in improving ...

  5. Risk factors for repetition of self-harm: a systematic review of prospective hospital-based studies.

    Directory of Open Access Journals (Sweden)

    Celine Larkin

    Full Text Available BACKGROUND: Self-harm entails high costs to individuals and society in terms of suicide risk, morbidity and healthcare expenditure. Repetition of self-harm confers yet higher risk of suicide and risk assessment of self-harm patients forms a key component of the health care management of self-harm patients. To date, there has been no systematic review published which synthesises the extensive evidence on risk factors for repetition. OBJECTIVE: This review is intended to identify risk factors for prospective repetition of self-harm after an index self-harm presentation, irrespective of suicidal intent. DATA SOURCES: PubMed, PsychInfo and Scirus were used to search for relevant publications. We included cohort studies which examining factors associated with prospective repetition among those presenting with self-harm to emergency departments. Journal articles, abstracts, letters and theses in any language published up to June 2012 were considered. Studies were quality-assessed and synthesised in narrative form. RESULTS: A total of 129 studies, including 329,001 participants, met our inclusion criteria. Some factors were studied extensively and were found to have a consistent association with repetition. These included previous self-harm, personality disorder, hopelessness, history of psychiatric treatment, schizophrenia, alcohol abuse/dependence, drug abuse/dependence, and living alone. However, the sensitivity values of these measures varied greatly across studies. Psychological risk factors and protective factors have been relatively under-researched but show emerging associations with repetition. Composite risk scales tended to have high sensitivity but poor specificity. CONCLUSIONS: Many risk factors for repetition of self-harm match risk factors for initiation of self-harm, but the most consistent evidence for increased risk of repetition comes from long-standing psychosocial vulnerabilities, rather than characteristics of an index episode

  6. FEMA Hazard Mitigation Assistance Severe Repetitive Loss (SRL) Data

    Data.gov (United States)

    Department of Homeland Security — This dataset contains closed and obligated projects funded under the following Hazard Mitigation Assistance (HMA) grant programs: Severe Repetitive Loss (SRL). The...

  7. FEMA Hazard Mitigation Assistance Repetitive Flood Claims (RFC) Data

    Data.gov (United States)

    Department of Homeland Security — This dataset contains closed and obligated projects funded under the following Hazard Mitigation Assistance (HMA) grant programs: Repetitive Flood Claims (RFC). The...

  8. Reduced sensitivity of the N400 and late positive component to semantic congruity and word repetition in left temporal lobe epilepsy.

    Science.gov (United States)

    Olichney, John M; Riggins, Brock R; Hillert, Dieter G; Nowacki, Ralph; Tecoma, Evelyn; Kutas, Marta; Iragui, Vicente J

    2002-07-01

    We studied 14 patients with well-characterized refractory temporal lobe epilepsy (TLE), 7 with right temporal lobe epilepsy (RTE) and 7 with left temporal lobe epilepsy (LTE), on a word repetition ERP experiment. Much prior literature supports the view that patients with left TLE are more likely to develop verbal memory deficits, often attributable to left hippocampal sclerosis. Our main objectives were to test if abnormalities of the N400 or Late Positive Component (LPC, P600) were associated with a left temporal seizure focus, or left temporal lobe dysfunction. A minimum of 19 channels of EEG/EOG data were collected while subjects performed a semantic categorization task. Auditory category statements were followed by a visual target word, which were 50% "congruous" (category exemplars) and 50% "incongruous" (non-category exemplars) with the preceding semantic context. These auditory-visual pairings were repeated pseudo-randomly at time intervals ranging from approximately 10-140 seconds later. The ERP data were submitted to repeated-measures ANOVAs, which showed the RTE group had generally normal effects of word repetition on the LPC and the N400. Also, the N400 component was larger to incongruous than congruous new words, as is normally the case. In contrast, the LTE group did not have statistically significant effects of either word repetition or congruity on their ERPs (N400 or LPC), suggesting that this ERP semantic categorization paradigm is sensitive to left temporal lobe dysfunction. Further studies are ongoing to determine if these ERP abnormalities predict hippocampal sclerosis on histopathology, or outcome after anterior temporal lobectomy.

  9. Development of a mobile device optimized cross platform-compatible oral pathology and radiology spaced repetition system for dental education.

    Science.gov (United States)

    Al-Rawi, Wisam; Easterling, Lauren; Edwards, Paul C

    2015-04-01

    Combining active recall testing with spaced repetition increases memory retention. The aim of this study was to evaluate and compare students' perception and utilization of an electronic spaced repetition oral pathology-radiology system in dental hygiene education and predoctoral dental education. The study employed an open-source suite of applications to create electronic "flashcards" that can be individually adjusted for frequency of repetition, depending on a user's assessment of difficulty. Accessible across multiple platforms (iOS, Android, Linux, OSX, Windows) as well as via any web-based browser, this framework was used to develop an oral radiology-oral pathology database of case-based questions. This system was introduced in two courses: sophomore oral pathology for dental students and sophomore radiology for dental hygiene students. Students were provided free software and/or mobile tablet devices as well as a database of 300 electronic question cards. Study participants were surveyed on frequency and extent of use. Perception-based surveys were used to evaluate their attitudes towards this technology. Of the eligible students, 12 of 22 (54.5%) dental hygiene and 49 of 107 (45.8%) dental students responded to the surveys. Adoption rates and student feedback were compared between the two groups. Among the respondents, acceptance of this technology with respect to educational usefulness was similar for the dental and dental hygiene students (median=5 on a five-point scale; dental hygiene interquartile range (IQR)=0; dental IQR=1). Only a minority of the survey respondents (25% dental, 33% dental hygiene) took advantage of one of the main benefits of this technology: automated spaced repetition.

  10. The development of a repetition-load scheme for the eccentric-only bench press exercise.

    Science.gov (United States)

    Moir, Gavin L; Erny, Kyle F; Davis, Shala E; Guers, John J; Witmer, Chad A

    2013-01-01

    The purpose of the present study was to develop a repetition-load scheme for the eccentric-only bench press exercise. Nine resistance trained men (age: 21.6 ± 1.0 years; 1-repetition maximum [RM] bench press: 137.7 ± 30.4 kg) attended four testing sessions during a four week period. During the first session each subject's 1-RM bench press load utilizing the stretch-shortening cycle was determined. During the remaining sessions they performed eccentric-only repetitions to failure using supra-maximal loads equivalent to 110%, 120% and 130% of their 1-RM value with a constant cadence (30 reps·min(-1)). Force plates and a three dimensional motion analysis system were used during these final three sessions in order to evaluate kinematic and kinetic variables. More repetitions were completed during the 110% 1-RM condition compared to the 130% 1-RM condition (p=0.01). Mean total work (p=0.046) as well as vertical force (p=0.049), vertical work (p=0.017), and vertical power output (p=0.05) were significantly greater during the 130% 1-RM condition compared to the 110% 1-RM condition. A linear function was fitted to the number of repetitions completed under each load condition that allowed the determination of the maximum number of repetitions that could be completed under other supra-maximal loads. This linear function predicted an eccentric-only 1-RM in the bench press with a load equivalent to 164.8% 1-RM, producing a load of 227.0 ± 50.0 kg. The repetition-load scheme presented here should provide a starting point for researchers to investigate the kinematic, kinetic and metabolic responses to eccentric-only bench press workouts.

  11. Shoulder muscle fatigue during repetitive tasks as measured by electromyography and near-infrared spectroscopy.

    Science.gov (United States)

    Ferguson, Sue A; Allread, W Gary; Le, Peter; Rose, Joseph; Marras, William S

    2013-12-01

    The objective of this study was to quantify shoulder muscle fatigue during repetitive exertions similar to motions found in automobile assembly tasks. Shoulder musculoskeletal disorders (MSDs) are a common and costly problem in automotive manufacturing. Ten subjects participated in the study. There were three independent variables: shoulder angle, frequency, and force. There were two types of dependent measures: percentage change in near-infrared spectroscopy (NIRS) measures and change in electromyography (EMG) median frequency. The anterior deltoid and trapezius muscles were measured for both NIRS and EMG. Also, EMG was collected on the middle deltoid and biceps muscles. The results showed that oxygenated hemoglobin decreased significantly due to the main effects (shoulder angle, frequency, and force). The percentage change in oxygenated hemoglobin had a significant interaction attributable to force and repetition for the anterior deltoid muscle, indicating that as repetition increased, the magnitude of the differences between the forces increased. The interaction of repetition and shoulder angle was also significant for the percentage change in oxygenated hemoglobin. The median frequency decreased significantly for the main effects; however, no interactions were statistically significant. There was significant shoulder muscle fatigue as a function of shoulder angle, task frequency, and force level. Furthermore, percentage change in oxygenated hemoglobin had two statistically significant interactions, enhancing our understanding of these risk factors. Ergonomists should examine interactions of force and repetition as well as shoulder angle and repetition when evaluating the risk of shoulder MSDs.

  12. Fatigue effects upon sticking region and electromyography in a six-repetition maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Saeterbakken, Atle Hole

    2013-01-01

    The aim of the study was to examine the sticking region and concomitant neuromuscular activation of the prime movers during six-repetition maximum (RM) bench pressing. We hypothesised that both peak velocities would decrease and that the electromyography (EMG) of the prime movers (deltoid, major pectoralis and triceps) would increase during the pre-sticking and sticking region during the six repetitions due to fatigue. Thirteen resistance-trained males (age 22.8 ± 2.2 years, stature 1.82 ± 0.06 m, body mass 83.4 ± 7.6 kg) performed 6-RM bench presses. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, and triceps brachii during the pre-, sticking and post-sticking region of each repetition in a 6-RM bench press were analysed. For both the sticking as the post-sticking region, the time increased significantly from the first to the sixth repetition. Vertical barbell height at the start of sticking region was lower, while the height at the end of the sticking region and post-sticking region did not change during the six repetitions. It was concluded that in 6-RM bench pressing performance, the sticking region is a poor mechanical force region due to the unchanged barbell height at the end of the sticking region. Furthermore, when fatigue occurs, the pectoralis and the deltoid muscles are responsible for surpassing the sticking region as indicated by their increased activity during the pre- and sticking region during the six-repetitions bench press.

  13. Change in power output across a high-repetition set of bench throws and jump squats in highly trained athletes.

    Science.gov (United States)

    Baker, Daniel G; Newton, Robert U

    2007-11-01

    Athletes experienced in maximal-power and power-endurance training performed 1 set of 2 common power training exercises in an effort to determine the effects of moderately high repetitions upon power output levels throughout the set. Twenty-four and 15 athletes, respectively, performed a set of 10 repetitions in both the bench throw (BT P60) and jump squat exercise (JS P60) with a resistance of 60 kg. For both exercises, power output was highest on either the second (JS P60) or the third repetition (BT P60) and was then maintained until the fifth repetition. Significant declines in power output occurred from the sixth repetition onwards until the 10th repetition (11.2% for BT P60 and 5% for JS P60 by the 10th repetition). These findings suggest that athletes attempting to increase maximal power limit their repetitions to 2 to 5 when using resistances of 35 to 45% 1RM in these exercises.

  14. Verbal Repetitions and Echolalia in Alzheimer's Discourse

    Science.gov (United States)

    Da Cruz, Fernanda Miranda

    2010-01-01

    This article reports on an investigation of echolalic repetition in Alzheimer's disease (AD). A qualitative analysis of data from spontaneous conversations with MHI, a woman with AD, is presented. The data come from the DALI Corpus, a corpus of spontaneous conversations involving subjects with AD. This study argues that echolalic effects can be…

  15. Maximal Repetitions in Written Texts: Finite Energy Hypothesis vs. Strong Hilberg Conjecture

    Directory of Open Access Journals (Sweden)

    Łukasz Dębowski

    2015-08-01

    Full Text Available The article discusses two mutually-incompatible hypotheses about the stochastic mechanism of the generation of texts in natural language, which could be related to entropy. The first hypothesis, the finite energy hypothesis, assumes that texts are generated by a process with exponentially-decaying probabilities. This hypothesis implies a logarithmic upper bound for maximal repetition, as a function of the text length. The second hypothesis, the strong Hilberg conjecture, assumes that the topological entropy grows as a power law. This hypothesis leads to a hyperlogarithmic lower bound for maximal repetition. By a study of 35 written texts in German, English and French, it is found that the hyperlogarithmic growth of maximal repetition holds for natural language. In this way, the finite energy hypothesis is rejected, and the strong Hilberg conjecture is partly corroborated.

  16. The effect of music on repetitive disruptive vocalizations of persons with dementia.

    Science.gov (United States)

    Casby, J A; Holm, M B

    1994-10-01

    This study examined the effect of classical music and favorite music on the repetitive disruptive vocalizations of long-term-care facility (LTCF) residents with dementia of the Alzheimer's type (DAT). Three subjects diagnosed with DAT who had a history of repetitive disruptive vocalizations were selected for the study. Three single-subject withdrawal designs (ABA, ACA, and ABCA) were used to assess subjects' repetitive disruptive vocalizations during each phase: no intervention (A); relaxing, classical music (B); and favorite music (C). Classical music and favorite music significantly decreased the number of vocalizations in two of the three subjects (p < .05). These findings support a method that was effective in decreasing the disruptive vocalization pattern common in those with DAT in the least restrictive manner, as mandated by the Omnibus Budget Reconciliation Act of 1987.

  17. Refining borders of genome-rearrangements including repetitions

    Directory of Open Access Journals (Sweden)

    JA Arjona-Medina

    2016-10-01

    Full Text Available Abstract Background DNA rearrangement events have been widely studied in comparative genomic for many years. The importance of these events resides not only in the study about relatedness among different species, but also to determine the mechanisms behind evolution. Although there are many methods to identify genome-rearrangements (GR, the refinement of their borders has become a huge challenge. Until now no accepted method exists to achieve accurate fine-tuning: i.e. the notion of breakpoint (BP is still an open issue, and despite repeated regions are vital to understand evolution they are not taken into account in most of the GR detection and refinement methods. Methods and results We propose a method to refine the borders of GR including repeated regions. Instead of removing these repetitions to facilitate computation, we take advantage of them using a consensus alignment sequence of the repeated region in between two blocks. Using the concept of identity vectors for Synteny Blocks (SB and repetitions, a Finite State Machine is designed to detect transition points in the difference between such vectors. The method does not force the BP to be a region or a point but depends on the alignment transitions within the SBs and repetitions. Conclusion The accurate definition of the borders of SB and repeated genomic regions and consequently the detection of BP might help to understand the evolutionary model of species. In this manuscript we present a new proposal for such a refinement. Features of the SBs borders and BPs are different and fit with what is expected. SBs with more diversity in annotations and BPs short and richer in DNA replication and stress response, which are strongly linked with rearrangements.

  18. Bystanders' Reactions to Witnessing Repetitive Abuse Experiences

    Science.gov (United States)

    Janson, Gregory R.; Carney, JoLynn V.; Hazler, Richard J.; Oh, Insoo

    2009-01-01

    The Impact of Event Scale-Revised (D. S. Weiss & C. R. Marmar, 1997) was used to obtain self-reported trauma levels from 587 young adults recalling childhood or adolescence experiences as witnesses to common forms of repetitive abuse defined as bullying. Mean participant scores were in a range suggesting potential need for clinical assessment…

  19. Context-Dependent Repetition Effects on Recognition Memory

    Science.gov (United States)

    Opitz, Bertram

    2010-01-01

    One widely acknowledged way to improve our memory performance is to repeatedly study the to be learned material. One aspect that has received little attention in past research regards the context sensitivity of this repetition effect, that is whether the item is repeated within the same or within different contexts. The predictions of a…

  20. Matriculation Research Report: Course Repetition Data & Analysis.

    Science.gov (United States)

    Gerda, Joe

    Due to concerns that its policy on class repetition was not promoting student success, California's College of the Canyons (CoC) undertook a project to analyze student course-taking patterns and make recommendations to modify the policy. Existing college policy did not follow Section 58161 of the State Educational Code that allows colleges to…

  1. Repetitively pulsed material testing facility

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Gullickson, R.; Long, J.; Luce, J.; Sahlin, H.

    1975-01-01

    A continuously operated, 1 pps, dense-plasma-focus device capable of delivering a minimum of 10 15 neutrons per pulse for material testing purposes is described. Moderate scaling from existing results is sufficient to provide 2 x 10 13 n/cm 2 . s to a suitable target. The average power consumption, which has become a major issue as a result of the energy crisis, is analyzed with respect to other plasma devices and is shown to be highly favorable. A novel approach to the capacitor bank and switch design allowing repetitive operation is discussed

  2. Repetitive cryotherapy attenuates the in vitro and in vivo mononuclear cell activation response.

    Science.gov (United States)

    Lindsay, Angus; Othman, Mohd Izani; Prebble, Hannah; Davies, Sian; Gieseg, Steven P

    2016-07-01

    What is the central question of this study? Acute and repetitive cryotherapy are routinely used to accelerate postexercise recovery, although the effect on resident immune cells and repetitive exposure has largely been unexplored and neglected. What is the main finding and its importance? Using blood-derived mononuclear cells and semi-professional mixed martial artists, we show that acute and repetitive cryotherapy reduces the in vitro and in vivo T-cell and monocyte activation response whilst remaining independent of the physical performance of elite athletes. We investigated the effect of repetitive cryotherapy on the in vitro (cold exposure) and in vivo (cold water immersion) activation of blood-derived mononuclear cells following high-intensity exercise. Single and repeated cold exposure (5°C) of a mixed cell culture (T cells and monocytes) was investigated using in vitro tissue culture experimentation for total neopterin production (neopterin plus 7,8-dihydroneopterin). Fourteen elite mixed martial art fighters were also randomly assigned to either a cold water immersion (15 min at 10°C) or passive recovery protocol, which they completed three times per week during a 6 week training camp. Urine was collected and analysed for neopterin and total neopterin three times per week, and perceived soreness, fatigue, physical performance (broad jump, push-ups and pull-ups) and training performance were also assessed. Single and repetitive cold exposure significantly (P cryotherapy attenuates in vitro T-cell and monocyte activation. This may explain the disparity in in vivo neopterin and total neopterin between cold water immersion and passive recovery following repetitive exposure during a high-intensity physical impact sport that remains independent of physical performance. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

  3. Functions of repetition in the discourse of elderly speakers: The role of prosody and gesture

    OpenAIRE

    Bolly, Catherine; Gerstenberg, Annette; 14th International Pragmatics Conference (IPra), Panel session "Age and language use"

    2015-01-01

    Cognitively speaking, repetition can work as a facilitator for both the planning and the understanding of spoken language. It can work as a cohesive and interactive device or, at a higher-level function of discourse, to engage in interaction by creating interpersonal involvement: repetition always conveys altered meaning, as it has to be re-interpreted by the interlocutor “in light of the accretion, juxtaposition, or expansion” (Tannen 2007: 62). Repetition is thus useful for the building of ...

  4. Cumulative Repetition Effects across Multiple Readings of a Word: Evidence from Eye Movements

    Science.gov (United States)

    Kamienkowski, Juan E.; Carbajal, M. Julia; Bianchi, Bruno; Sigman, Mariano; Shalom, Diego E.

    2018-01-01

    When a word is read more than once, reading time generally decreases in the successive occurrences. This Repetition Effect has been used to study word encoding and memory processes in a variety of experimental measures. We studied naturally occurring repetitions of words within normal texts (stories of around 3,000 words). Using linear mixed…

  5. Ways of Viewing Pictorial Plasticity

    Directory of Open Access Journals (Sweden)

    Maarten W. A. Wijntjes

    2017-03-01

    Full Text Available The plastic effect is historically used to denote various forms of stereopsis. The vivid impression of depth often associated with binocular stereopsis can also be achieved in other ways, for example, using a synopter. Accounts of this go back over a hundred years. These ways of viewing all aim to diminish sensorial evidence that the picture is physically flat. Although various viewing modes have been proposed in the literature, their effects have never been compared. In the current study, we compared three viewing modes: monocular blur, synoptic viewing, and free viewing (using a placebo synopter. By designing a physical embodiment that was indistinguishable for the three experimental conditions, we kept observers naïve with respect to the differences between them; 197 observers participated in an experiment where the three viewing modes were compared by performing a rating task. Results indicate that synoptic viewing causes the largest plastic effect. Monocular blur scores lower than synoptic viewing but is still rated significantly higher than the baseline conditions. The results strengthen the idea that synoptic viewing is not due to a placebo effect. Furthermore, monocular blur has been verified for the first time as a way of experiencing the plastic effect, although the effect is smaller than synoptic viewing. We discuss the results with respect to the theoretical basis for the plastic effect. We show that current theories are not described with sufficient details to explain the differences we found.

  6. Ways of Viewing Pictorial Plasticity.

    Science.gov (United States)

    Wijntjes, Maarten W A

    2017-01-01

    The plastic effect is historically used to denote various forms of stereopsis. The vivid impression of depth often associated with binocular stereopsis can also be achieved in other ways, for example, using a synopter. Accounts of this go back over a hundred years. These ways of viewing all aim to diminish sensorial evidence that the picture is physically flat. Although various viewing modes have been proposed in the literature, their effects have never been compared. In the current study, we compared three viewing modes: monocular blur, synoptic viewing, and free viewing (using a placebo synopter). By designing a physical embodiment that was indistinguishable for the three experimental conditions, we kept observers naïve with respect to the differences between them; 197 observers participated in an experiment where the three viewing modes were compared by performing a rating task. Results indicate that synoptic viewing causes the largest plastic effect. Monocular blur scores lower than synoptic viewing but is still rated significantly higher than the baseline conditions. The results strengthen the idea that synoptic viewing is not due to a placebo effect. Furthermore, monocular blur has been verified for the first time as a way of experiencing the plastic effect, although the effect is smaller than synoptic viewing. We discuss the results with respect to the theoretical basis for the plastic effect. We show that current theories are not described with sufficient details to explain the differences we found.

  7. Measuring Glial Metabolism in Repetitive Brain Trauma and Alzheimer’s Disease

    Science.gov (United States)

    2016-09-01

    stages of repetitive brain trauma as well. Current methods of measure brain glutamate using proton spectroscopy is not specific to different cell...covering a representative range of clinical cases: a young female , young male , middle-aged male (all healthy volunteers) and a male patient with...AWARD NUMBER: W81XWH-15-1-0412 TITLE: Measuring Glial Metabolism in Repetitive Brain Trauma and Alzheimer’s Disease PRINCIPAL INVESTIGATOR

  8. The relationship between executive functioning, central coherence, and repetitive behaviors in the high-functioning autism spectrum.

    Science.gov (United States)

    South, Mikle; Ozonoff, Sally; McMahon, William M

    2007-09-01

    This study examined the relationship between everyday repetitive behavior (primary symptoms of autism) and performance on neuropsychological tests of executive function and central coherence (secondary symptoms). It was hypothesized that the frequency and intensity of repetitive behavior would be positively correlated with laboratory measures of cognitive rigidity and weak central coherence. Participants included 19 individuals (ages 10-19) with high-functioning autism spectrum disorders (ASD group) and 18 age- and IQ-matched typically developing controls (TD group). There was partial support in the ASD group for the link between repetitive behavior and executive performance (the Wisconsin Card Sorting Task). There was no support for a link between repetitive behavior and measures of central coherence (a Gestalt Closure test and the Embedded Figures Test). Further research on repetitive behaviors in autism may benefit from a focus on narrow behavioral and cognitive constructs rather than general categories.

  9. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Baksht, E Kh; Burachenko, A G; Lomaev, M I; Panchenko, A N; Tarasenko, V F [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

    2015-04-30

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ∼4 ns and a rise time of ∼2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 – 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr. (laser applications and other topics in quantum electronics)

  10. Repetitive MEGAMP per microsecond di/dt pulsers for driving sub-ohm transmission line neutrino particle detectors

    International Nuclear Information System (INIS)

    Krausse, G.J.

    1980-01-01

    With the advent of low-cost honeycomb extrusions of polypropylene sheets, transmission line flash chambers have become highly attractive candidates for large particle detector arrays. This has brought about the need for repetitive pulse systems that must provide exceptionally high peak currents, low levels of spurious radiation, high reliability, and shot life in excess of 10 7 . Each module of 10 flash chambers requires a peak current of 20 kA with a current di/dt greater than 1 MA/μs. The pulser output must develop approx. = 7 kV across a load of 0.5 Ω with a pulse width of 500 ns. The complete system will require 40 pulsers run in parallel for a combined current output of 1.4 MA peak with a system di/dt of 40 MA/μs. The repetition rate will be up to 2 Hz. This paper describes the development of such a system, its unique voltage and current diagnostics, and the impact of the physical limitations of present component technology on lifetime, reliability, maintainability, and pulse fidelity

  11. Perseveration and other repetitive verbal behaviors: functional dissociations.

    Science.gov (United States)

    Christman, Sarah S; Boutsen, Frank R; Buckingham, Hugh W

    2004-11-01

    This article will review types of perseveration from a neurolinguistic perspective. During the course of the article, continuous, stuck-in-set, and recurrent perseveration will be placed in contradistinction to several other types of repetitive behaviors commonly associated with neurogenic communication disorders. These include echolalia in mixed transcortical aphasia; conduite d'approche and conduite d'ecart in fluent aphasias; lexical and nonlexical automatisms in nonfluent aphasias; palilalia in neuromotor disorders, such as Parkinson's disease (PD); and sound, syllable, word, and phrase repetitions in neurogenic stuttering. When differentiating these phenomena from perseveration, it is helpful to consider the salient factors that condition observed behaviors in individual patients, such as overall speech fluency, inventory of available utterances, nature of eliciting tasks, and propositionality of responses. Information such as communication disorder diagnosis, underlying etiology, and known sites of lesion from each patient's total clinical profile may also assist with differentiation.

  12. Task Repetition Effects on L1 Use in EFL Child Task-Based Interaction

    Science.gov (United States)

    Azkarai, Agurtzane; García Mayo, María del Pilar

    2017-01-01

    Research has shown that tasks provide second language (L2) learners with many opportunities to learn the L2. Task repetition has been claimed to benefit L2 learning since familiarity with procedure and/or content gives learners the chance to focus on more specific aspects of language. Most research on task repetition has focused on adult…

  13. Understanding and defining bullying - adolescents' own views.

    Science.gov (United States)

    Hellström, Lisa; Persson, Louise; Hagquist, Curt

    2015-01-01

    The negative consequences of peer-victimization on children and adolescents are major public health concerns which have been subjected to extensive research. Given all efforts made to analyze and estimate the social and health consequences of peer-victimization, the adolescents' own experiences and understandings have had surprisingly little impact on the definition of bullying. Therefore, the aim of the current study is to explore adolescents' definitions of bullying. A questionnaire study (n = 128) and four focus group interviews (n = 21) were conducted among students aged 13 and 15. First, gender and age differences were analyzed with respect to what behaviors are considered bullying (questionnaire data). Second, analysis of what bullying is (focus group interviews) was conducted using qualitative content analysis. The adolescents own understanding and definition of bullying didn't just include the traditional criteria of repetition and power imbalance, but also a criterion based on the health consequences of bullying. The results showed that a single but hurtful or harmful incident also could be considered bullying irrespective of whether the traditional criteria were fulfilled or not. Further, girls and older students had a more inclusive view of bullying and reported more types of behaviors as bullying compared to boys and younger students. The results of the current study adds to the existing literature by showing that adolescents consider the victim's experience of hurt and harm as a criterion for defining bullying and not only as consequences of bullying. This may be of special relevance for the identification and classification of bullying incidents on the internet where devastating consequences have been reported from single incidents and the use of the traditional criteria of intent, repetition and power imbalance may not be as relevant as for traditional bullying. It implies that the traditional criteria included in most definitions of bullying

  14. Contrasting the Chromosomal Organization of Repetitive DNAs in Two Gryllidae Crickets with Highly Divergent Karyotypes.

    Directory of Open Access Journals (Sweden)

    Octavio M Palacios-Gimenez

    Full Text Available A large percentage of eukaryotic genomes consist of repetitive DNA that plays an important role in the organization, size and evolution. In the case of crickets, chromosomal variability has been found using classical cytogenetics, but almost no information concerning the organization of their repetitive DNAs is available. To better understand the chromosomal organization and diversification of repetitive DNAs in crickets, we studied the chromosomes of two Gryllidae species with highly divergent karyotypes, i.e., 2n(♂ = 29,X0 (Gryllus assimilis and 2n = 9, neo-X1X2Y (Eneoptera surinamensis. The analyses were performed using classical cytogenetic techniques, repetitive DNA mapping and genome-size estimation. Conserved characteristics were observed, such as the occurrence of a small number of clusters of rDNAs and U snDNAs, in contrast to the multiple clusters/dispersal of the H3 histone genes. The positions of U2 snDNA and 18S rDNA are also conserved, being intermingled within the largest autosome. The distribution and base-pair composition of the heterochromatin and repetitive DNA pools of these organisms differed, suggesting reorganization. Although the microsatellite arrays had a similar distribution pattern, being dispersed along entire chromosomes, as has been observed in some grasshopper species, a band-like pattern was also observed in the E. surinamensis chromosomes, putatively due to their amplification and clustering. In addition to these differences, the genome of E. surinamensis is approximately 2.5 times larger than that of G. assimilis, which we hypothesize is due to the amplification of repetitive DNAs. Finally, we discuss the possible involvement of repetitive DNAs in the differentiation of the neo-sex chromosomes of E. surinamensis, as has been reported in other eukaryotic groups. This study provided an opportunity to explore the evolutionary dynamics of repetitive DNAs in two non-model species and will contribute to the

  15. Effect of parallel magnetic field on repetitively unipolar nanosecond pulsed dielectric barrier discharge under different pulse repetition frequencies

    Science.gov (United States)

    Liu, Yidi; Yan, Huijie; Guo, Hongfei; Fan, Zhihui; Wang, Yuying; Wu, Yun; Ren, Chunsheng

    2018-03-01

    A magnetic field, with the direction parallel to the electric field, is applied to the repetitively unipolar positive nanosecond pulsed dielectric barrier discharge. The effect of the parallel magnetic field on the plasma generated between two parallel-plate electrodes in quiescent air is experimentally studied under different pulse repetition frequencies (PRFs). It is indicated that only the current pulse in the rising front of the voltage pulse occurs, and the value of the current is increased by the parallel magnetic field under different PRFs. The discharge uniformity is improved with the decrease in PRF, and this phenomenon is also observed in the discharge with the parallel magnetic field. By using the line-ratio technique of optical emission spectra, it is found that the average electron density and electron temperature under the considered PRFs are both increased when the parallel magnetic field is applied. The incremental degree of average electron density is basically the same under the considered PRFs, while the incremental degree of electron temperature under the higher-PRFs is larger than that under the lower-PRFs. All the above phenomena are explained by the effect of parallel magnetic field on diffusion and dissipation of electrons.

  16. Repetitive transient extraction for machinery fault diagnosis using multiscale fractional order entropy infogram

    Science.gov (United States)

    Xu, Xuefang; Qiao, Zijian; Lei, Yaguo

    2018-03-01

    The presence of repetitive transients in vibration signals is a typical symptom of local faults of rotating machinery. Infogram was developed to extract the repetitive transients from vibration signals based on Shannon entropy. Unfortunately, the Shannon entropy is maximized for random processes and unable to quantify the repetitive transients buried in heavy random noise. In addition, the vibration signals always contain multiple intrinsic oscillatory modes due to interaction and coupling effects between machine components. Under this circumstance, high values of Shannon entropy appear in several frequency bands or high value of Shannon entropy doesn't appear in the optimal frequency band, and the infogram becomes difficult to interpret. Thus, it also becomes difficult to select the optimal frequency band for extracting the repetitive transients from the whole frequency bands. To solve these problems, multiscale fractional order entropy (MSFE) infogram is proposed in this paper. With the help of MSFE infogram, the complexity and nonlinear signatures of the vibration signals can be evaluated by quantifying spectral entropy over a range of scales in fractional domain. Moreover, the similarity tolerance of MSFE infogram is helpful for assessing the regularity of signals. A simulation and two experiments concerning a locomotive bearing and a wind turbine gear are used to validate the MSFE infogram. The results demonstrate that the MSFE infogram is more robust to the heavy noise than infogram and the high value is able to only appear in the optimal frequency band for the repetitive transient extraction.

  17. Development of highly repetitive pulse power system using amorphous metallic cores

    Energy Technology Data Exchange (ETDEWEB)

    Masugata, K; Yatsui, K [Nagaoka Univ. of Technology (Japan). Dept. of Electrical Engineering

    1997-12-31

    A new type of pulse power system has been developed to obtain an efficient highly repetitive pulse-power generation. The system is constructed of a double pulse circuit (1st stage), step-up transformer and Blumlein pulse forming line (BL) and can generate high power pulse of 600 kV, 24 kA, 60 ns. In the system, discharge gap switches are replaced by magnetic switches. In addition, instead of Marx generator, a step-up transformer is utilized to generate high voltage pulse. The system is tested under the double pulse mode where two 1st stage capacitors are connected in parallel and switched with a interval of T{sub d}. The minimum value of T{sub d} is limited by the recovery of 1st stage gap switches and at T{sub d} {>=} 500 {mu}s (equivalent rep-rate of 2 kHz), the system is operated with good reproducibility. To enhance the recovery, magnetic switch is utilized, which enables operation at T{sub d} {>=} 30 {mu}s (equivalent rep-rate of 33 kHz). (author). 7 figs., 7 refs.

  18. Robustification and Optimization in Repetitive Control For Minimum Phase and Non-Minimum Phase Systems

    Science.gov (United States)

    Prasitmeeboon, Pitcha

    repetitive control FIR compensator. The aim is to reduce the final error level by using real time frequency response model updates to successively increase the cutoff frequency, each time creating the improved model needed to produce convergence zero error up to the higher cutoff. Non-minimum phase systems present a difficult design challenge to the sister field of Iterative Learning Control. The third topic investigates to what extent the same challenges appear in RC. One challenge is that the intrinsic non-minimum phase zero mapped from continuous time is close to the pole of repetitive controller at +1 creating behavior similar to pole-zero cancellation. The near pole-zero cancellation causes slow learning at DC and low frequencies. The Min-Max cost function over the learning rate is presented. The Min-Max can be reformulated as a Quadratically Constrained Linear Programming problem. This approach is shown to be an RC design approach that addresses the main challenge of non-minimum phase systems to have a reasonable learning rate at DC. Although it was illustrated that using the Min-Max objective improves learning at DC and low frequencies compared to other designs, the method requires model accuracy at high frequencies. In the real world, models usually have error at high frequencies. The fourth topic addresses how one can merge the quadratic penalty to the Min-Max cost function to increase robustness at high frequencies. The topic also considers limiting the Min-Max optimization to some frequencies interval and applying an FIR zero-phase low-pass filter to cutoff the learning for frequencies above that interval.

  19. Repetitive controller for improving grid-connected photovoltaic systems

    NARCIS (Netherlands)

    Almeida, de P.M.; Duarte, J.L.; Ribeiro, P.F.; Barbosa, P.G.

    2014-01-01

    This study presents the modelling and design steps of a discrete time recursive repetitive controller (RC) to be used in a grid-connected photovoltaic (PV) system. It is shown that the linear synchronous reference frame proportional-integral controller, originally designed to control the converter's

  20. Stimulus repetition and the perception of time: the effects of prior exposure on temporal discrimination, judgment, and production.

    Directory of Open Access Journals (Sweden)

    William J Matthews

    Full Text Available It has been suggested that repeated stimuli have shorter subjective duration than novel items, perhaps because of a reduction in the neural response to repeated presentations of the same object. Five experiments investigated the effects of repetition on time perception and found further evidence that immediate repetition reduces apparent duration, consistent with the idea that subjective duration is partly based on neural coding efficiency. In addition, the experiments found (a no effect of repetition on the precision of temporal discrimination, (b that the effects of repetition disappeared when there was a modest lag between presentations, (c that, across participants, the size of the repetition effect correlated with temporal discrimination, and (d that the effects of repetition suggested by a temporal production task were the opposite of those suggested by temporal judgments. The theoretical and practical implications of these results are discussed.

  1. Models of epidemics: when contact repetition and clustering should be included

    Directory of Open Access Journals (Sweden)

    Scholz Roland W

    2009-06-01

    Full Text Available Abstract Background The spread of infectious disease is determined by biological factors, e.g. the duration of the infectious period, and social factors, e.g. the arrangement of potentially contagious contacts. Repetitiveness and clustering of contacts are known to be relevant factors influencing the transmission of droplet or contact transmitted diseases. However, we do not yet completely know under what conditions repetitiveness and clustering should be included for realistically modelling disease spread. Methods We compare two different types of individual-based models: One assumes random mixing without repetition of contacts, whereas the other assumes that the same contacts repeat day-by-day. The latter exists in two variants, with and without clustering. We systematically test and compare how the total size of an outbreak differs between these model types depending on the key parameters transmission probability, number of contacts per day, duration of the infectious period, different levels of clustering and varying proportions of repetitive contacts. Results The simulation runs under different parameter constellations provide the following results: The difference between both model types is highest for low numbers of contacts per day and low transmission probabilities. The number of contacts and the transmission probability have a higher influence on this difference than the duration of the infectious period. Even when only minor parts of the daily contacts are repetitive and clustered can there be relevant differences compared to a purely random mixing model. Conclusion We show that random mixing models provide acceptable estimates of the total outbreak size if the number of contacts per day is high or if the per-contact transmission probability is high, as seen in typical childhood diseases such as measles. In the case of very short infectious periods, for instance, as in Norovirus, models assuming repeating contacts will also behave

  2. Software-engineering-based model for mitigating Repetitive Strain ...

    African Journals Online (AJOL)

    The incorporation of Information and Communication Technology (ICT) in virtually all facets of human endeavours has fostered the use of computers. This has induced Repetitive Stress Injury (RSI) for continuous and persistent computer users. Proposing a software engineering model capable of enacted RSI force break ...

  3. High resolution Thomson scattering on the COMPASS tokamak - extending edge plasma view and increasing repetition rate

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Böhm, Petr; Aftanas, Milan; Šos, Miroslav; Havránek, Aleš; Šesták, David; Weinzettl, Vladimír; Hron, Martin; Pánek, Radomír

    2018-01-01

    Roč. 13, č. 1 (2018), č. článku C01024. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017] R&D Projects: GA ČR(CZ) GA14-35260S; GA MŠk(CZ) 8D15001; GA MŠk(CZ) LM2015045 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : Plasma diagnostics - interferometry * spectroscopy and imaging * Trigger concepts and systems (hardware and software) Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01024/meta

  4. Cognitive Impairments and Depressive Symptoms Did Not Impede Upper Extremity Recovery in a Clinical Repetitive Task Practice Program after Stroke

    Science.gov (United States)

    Skidmore, Elizabeth R.; Becker, James T.; Whyte, Ellen M.; Huber, Lynne M.; Waterstram, Laura F.; Ward, Amalie Andrew; Grattan, Emily S.; Holm, Margo B.

    2012-01-01

    Objective We examined whether cognitive impairments or depressive symptoms impeded improvement in upper extremity function in a clinical repetitive task practice program. Design Participants had mild to moderate upper extremity impairment after stroke (n=20). We characterized baseline cognitive function and depressive symptoms with the Repeatable Battery of Neuropsychological Status and the Hamilton Rating Scale for Depression. We measured upper extremity function at baseline, week 4 and week 24 with the Action Research Arm Test. Results Participants with and without cognitive impairments improved significantly over time (F1,17=84.48, pstroke (t17=.07, p=.95). Participants with and without depressive symptoms improved significantly over time (F1,18=86.29, pstroke (t17=.06, p=.95). Conclusions Preliminary findings suggest that cognitive impairments and depressive symptoms may not impede benefit from repetitive task practice after stroke. PMID:22311057

  5. Molecular typing of Lactobacillus brevis isolates from Korean food using repetitive element-polymerase chain reaction.

    Science.gov (United States)

    Kaur, Jasmine; Sharma, Anshul; Lee, Sulhee; Park, Young-Seo

    2018-06-01

    Lactobacillus brevis is a part of a large family of lactic acid bacteria that are present in cheese, sauerkraut, sourdough, silage, cow manure, feces, and the intestinal tract of humans and rats. It finds its use in food fermentation, and so is considered a "generally regarded as safe" organism. L. brevis strains are extensively used as probiotics and hence, there is a need for identifying and characterizing these strains. For identification and discrimination of the bacterial species at the subspecific level, repetitive element-polymerase chain reaction method is a reliable genomic fingerprinting tool. The objective of the present study was to characterize 13 strains of L. brevis isolated from various fermented foods using repetitive element-polymerase chain reaction. Repetitive element-polymerase chain reaction was performed using three primer sets, REP, Enterobacterial Repetitive Intergenic Consensus (ERIC), and (GTG) 5 , which produced different fingerprinting patterns that enable us to distinguish between the closely related strains. Fingerprinting patterns generated band range in between 150 and 5000 bp with REP, 200-7500 bp with ERIC, and 250-2000 bp with (GTG) 5 primers, respectively. The Jaccard's dissimilarity matrices were used to obtain dendrograms by the unweighted neighbor-joining method using genetic dissimilarities based on repetitive element-polymerase chain reaction fingerprinting data. Repetitive element-polymerase chain reaction proved to be a rapid and easy method that can produce reliable results in L. brevis species.

  6. Decreased microvascular cerebral blood flow assessed by diffuse correlation spectroscopy after repetitive concussions in mice.

    Science.gov (United States)

    Buckley, Erin M; Miller, Benjamin F; Golinski, Julianne M; Sadeghian, Homa; McAllister, Lauren M; Vangel, Mark; Ayata, Cenk; Meehan, William P; Franceschini, Maria Angela; Whalen, Michael J

    2015-12-01

    Repetitive concussions are associated with long-term cognitive dysfunction that can be attenuated by increasing the time intervals between concussions; however, biomarkers of the safest rest interval between injuries remain undefined. We hypothesize that deranged cerebral blood flow (CBF) is a candidate biomarker for vulnerability to repetitive concussions. Using a mouse model of human concussion, we examined the effect of single and repetitive concussions on cognition and on an index of CBF (CBFi) measured with diffuse correlation spectroscopy. After a single mild concussion, CBFi was reduced by 35±4% at 4 hours (Pconcussions spaced 1 day apart, CBFi was also reduced from preinjury levels 4 hours after each concussion but had returned to preinjury levels by 72 hours after the final concussion. Interestingly, in this repetitive concussion model, lower CBFi values measured both preinjury and 4 hours after the third concussion were associated with worse performance on the Morris water maze assessed 72 hours after the final concussion. We conclude that low CBFi measured either before or early on in the evolution of injury caused by repetitive concussions could be a useful predictor of cognitive outcome.

  7. Methylation patterns of repetitive DNA sequences in germ cells of Mus musculus.

    OpenAIRE

    Sanford, J; Forrester, L; Chapman, V; Chandley, A; Hastie, N

    1984-01-01

    The major and the minor satellite sequences of Mus musculus were undermethylated in both sperm and oocyte DNAs relative to the amount of undermethylation observed in adult somatic tissue DNA. This hypomethylation was specific for satellite sequences in sperm DNA. Dispersed repetitive and low copy sequences show a high degree of methylation in sperm DNA; however, a dispersed repetitive sequence was undermethylated in oocyte DNA. This finding suggests a difference in the amount of total genomic...

  8. Repetitively pulsed material testing facility

    International Nuclear Information System (INIS)

    Zucker, O.; Bostick, W.; Gullickson, R; Long, J.; Luce, J.; Sahlin, H.

    1975-01-01

    A continuously operated, 1 pps, dense-plasma-focus device capable of delivering a minimum of 10 15 neutrons per pulse for material testing purposes is described. Moderate scaling from existing results is sufficient to provide 2 x 10 13 n/cm 2 .s to a suitable target. The average power consumption, which has become a major issue as a result of the energy crisis, is analyzed with respect to other plasma devices and is shown to be highly favorable. A novel approach to the capacitor bank and switch design allowing repetitive operation is discussed. (U.S.)

  9. Repetitive muscle compression reduces vascular mechano-sensitivity and the hyperemic response to muscle contraction.

    Science.gov (United States)

    Messere, A; Turturici, M; Millo, G; Roatta, S

    2017-06-01

    Animal studies have shown that the rapid hyperemic response to external muscle compression undergoes inactivation upon repetitive stimulation, but this phenomenon has never been observed in humans. The aim of the present study was to determine whether 1) the vascular mechano-sensitivity underlying muscle compression-induced hyperemia is inactivated in an inter-stimulus interval (ISI)-dependent fashion upon repetitive stimulation, as suggested by animal studies, and 2) whether such inactivation also attenuates contraction-induced hyperemia. Brachial artery blood flow was measured by echo Doppler sonography in 13 healthy adults in response to 1) single and repetitive cuff muscle compression (CMC) of the forearm (20 CMCs, 1 s ISI); 2) a sequence of CMC delivered at decreasing ISI from 120 to 2 s; and 3) electrically-stimulated contraction of the forearm muscles before and after repetitive CMC. The peak amplitude of hyperemia in response to CMC normalized to baseline decreased from 2.2 ± 0.6 to 1.4 ± 0.4 after repetitive CMC and, in general, was decreased at ISI < 240 s. The peak amplitude of contraction-induced hyperemia was attenuated after as compared to before repeated CMC (1.7 ± 0.4 and 2.6 ± 0.6, respectively). Mechano-sensitivity of the vascular network can be conditioned by previous mechanical stimulation, and such preconditioning may substantially decrease contraction-induced hyperemia.

  10. Sources of Phoneme Errors in Repetition: Perseverative, Neologistic, and Lesion Patterns in Jargon Aphasia

    Directory of Open Access Journals (Sweden)

    Emma Pilkington

    2017-05-01

    Full Text Available This study examined patterns of neologistic and perseverative errors during word repetition in fluent Jargon aphasia. The principal hypotheses accounting for Jargon production indicate that poor activation of a target stimulus leads to weakly activated target phoneme segments, which are outcompeted at the phonological encoding level. Voxel-lesion symptom mapping studies of word repetition errors suggest a breakdown in the translation from auditory-phonological analysis to motor activation. Behavioral analyses of repetition data were used to analyse the target relatedness (Phonological Overlap Index: POI of neologistic errors and patterns of perseveration in 25 individuals with Jargon aphasia. Lesion-symptom analyses explored the relationship between neurological damage and jargon repetition in a group of 38 aphasia participants. Behavioral results showed that neologisms produced by 23 jargon individuals contained greater degrees of target lexico-phonological information than predicted by chance and that neologistic and perseverative production were closely associated. A significant relationship between jargon production and lesions to temporoparietal regions was identified. Region of interest regression analyses suggested that damage to the posterior superior temporal gyrus and superior temporal sulcus in combination was best predictive of a Jargon aphasia profile. Taken together, these results suggest that poor phonological encoding, secondary to impairment in sensory-motor integration, alongside impairments in self-monitoring result in jargon repetition. Insights for clinical management and future directions are discussed.

  11. Repetition Suppression in the Left Inferior Frontal Gyrus Predicts Tone Learning Performance.

    Science.gov (United States)

    Asaridou, Salomi S; Takashima, Atsuko; Dediu, Dan; Hagoort, Peter; McQueen, James M

    2016-06-01

    Do individuals differ in how efficiently they process non-native sounds? To what extent do these differences relate to individual variability in sound-learning aptitude? We addressed these questions by assessing the sound-learning abilities of Dutch native speakers as they were trained on non-native tone contrasts. We used fMRI repetition suppression to the non-native tones to measure participants' neuronal processing efficiency before and after training. Although all participants improved in tone identification with training, there was large individual variability in learning performance. A repetition suppression effect to tone was found in the bilateral inferior frontal gyri (IFGs) before training. No whole-brain effect was found after training; a region-of-interest analysis, however, showed that, after training, repetition suppression to tone in the left IFG correlated positively with learning. That is, individuals who were better in learning the non-native tones showed larger repetition suppression in this area. Crucially, this was true even before training. These findings add to existing evidence that the left IFG plays an important role in sound learning and indicate that individual differences in learning aptitude stem from differences in the neuronal efficiency with which non-native sounds are processed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Social relevance drives viewing behavior independent of low-level salience in rhesus macaques

    Directory of Open Access Journals (Sweden)

    James Andrew Solyst

    2014-11-01

    Full Text Available Quantifying attention to social stimuli during the viewing of complex social scenes with eye tracking has proven to be a sensitive method in the diagnosis of autism spectrum disorders years before average clinical diagnosis. Rhesus macaques provide an ideal model for understanding the mechanisms underlying social viewing behavior, but to date no comparable behavioral task has been developed for use in monkeys. Using a novel scene-viewing task, we monitored the gaze of three rhesus macaques while they freely viewed well-controlled composed social scenes and analyzed the time spent viewing objects and monkeys. In each of six behavioral sessions, monkeys viewed a set of 90 images (540 unique scenes with each image presented twice. In two-thirds of the repeated scenes, either a monkey or an object was replaced with a novel item (manipulated scenes. When viewing a repeated scene, monkeys made longer fixations and shorter saccades, shifting from a rapid orienting to global scene contents to a more local analysis of fewer items. In addition to this repetition effect, in manipulated scenes, monkeys demonstrated robust memory by spending more time viewing the replaced items. By analyzing attention to specific scene content, we found that monkeys strongly preferred to view conspecifics and that this was not related to their salience in terms of low-level image features. A model-free analysis of viewing statistics found that monkeys that were viewed earlier and longer had direct gaze and redder sex skin around their face and rump, two important visual social cues. These data provide a quantification of viewing strategy, memory and social preferences in rhesus macaques viewing complex social scenes, and they provide an important baseline with which to compare to the effects of therapeutics aimed at enhancing social cognition.

  13. Involvement of Disperse Repetitive Sequences in Wheat/Rye Genome Adjustment

    Directory of Open Access Journals (Sweden)

    Manuela Silva

    2012-07-01

    Full Text Available The union of different genomes in the same nucleus frequently results in hybrid genotypes with improved genome plasticity related to both genome remodeling events and changes in gene expression. Most modern cereal crops are polyploid species. Triticale, synthesized by the cross between wheat and rye, constitutes an excellent model to study polyploidization functional implications. We intend to attain a deeper knowledge of dispersed repetitive sequence involvement in parental genome reshuffle in triticale and in wheat-rye addition lines that have the entire wheat genome plus each rye chromosome pair. Through Random Amplified Polymorphic DNA (RAPD analysis with OPH20 10-mer primer we unraveled clear alterations corresponding to the loss of specific bands from both parental genomes. Moreover, the sequential nature of those events was revealed by the increased absence of rye-origin bands in wheat-rye addition lines in comparison with triticale. Remodeled band sequencing revealed that both repetitive and coding genome domains are affected in wheat-rye hybrid genotypes. Additionally, the amplification and sequencing of pSc20H internal segments showed that the disappearance of parental bands may result from restricted sequence alterations and unraveled the involvement of wheat/rye related repetitive sequences in genome adjustment needed for hybrid plant stabilization.

  14. Comorbid psychopathology and stress mediate the relationship between autistic traits and repetitive behaviours in adults with autism.

    Science.gov (United States)

    García-Villamisar, D; Rojahn, J

    2015-02-01

    Comorbid psychopathology and stress were considered possible mediators that may explain the relationship between some autistic traits and repetitive behaviours. The current study sought to examine the mediational effects of comorbid psychopathology, executive dysfunctions and stress in the relationship between some autistic traits and repetitive behaviours. A battery of questionnaires including measures of autistic traits, repetitive behaviours, stress, executive dysfunctions and comorbid psychopathology were administered to a sample of adults with autism and intellectual disabilities (n = 43). We found that when taken as set dimensions of comorbidity, dysexecutive functioning and stress mediated or explained the effects of autistic symptoms on repetitive behaviour. The total model explained 60% of the variation in repetitive behaviours (R = 0.60; F = 13.64, P autism, while executive functioning did not contribute to that relationship. © 2013 2013 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  15. An evaluation of factors affecting duration of treatment with repetitive transcranial magnetic stimulation for depression

    Directory of Open Access Journals (Sweden)

    Roni Broder Cohen

    2007-12-01

    Full Text Available Objective: To investigate the effects of repetitive transcranialmagnetic stimulation in patients with major depression who weresubmitted to this treatment during the period from 2000 to 2006.Methods: A retrospective study with 204 patients who underwenttreatment with repetitive transcranial magnetic stimulation, collectingdata from those who experienced remission (defined as a HDRS scoreequal to or lower than 7. The patients were followed for up to 6 monthsafter treatment. Mean duration of remission for this cohort of patientswas 70.2 (± 58.4 days. Results: The only variable associated withthe duration of remission in the linear regression model was numberof repetitive transcranial magnetic stimulation sessions. Conclusion:Our findings suggest that the greater the number of sessions, the longerthe duration of repetitive transcranial magnetic stimulation effects.Consequently, future research investigating the effects of repetitivetranscranial magnetic stimulation should explore this variable in orderto maximize the therapeutic effects of this new brain stimulationtechnique.

  16. EFEKTIVITAS MODEL PEMBELAJARAN AUDITORY INTELLECTUALLY REPETITION (AIR TERHADAP PEMAHAMAN SISWA PADA KONSEP ENERGI DALAM

    Directory of Open Access Journals (Sweden)

    S. Linuwih

    2014-07-01

    Full Text Available Telah dilakukan pembelajaran fisika melalui penerapan model pembelajaran Auditory Intellectually Repetition (AIR pada pokok bahasan konsep energi dalam. Tujuan penelitian ini untuk mengetahui peningkatan pemahaman konsep siswa dan efektivitas model pembelajaran Auditory Intellectually Repetition (AIR terhadap pemahaman siswa pada konsep energi dalam. Penelitian ini menggunakan metode penelitian eksperimen kependidikan (educational experiment research, dengan rancangan pre test-post test control group design. Subjek penelitian adalah dua kelompok belajar yang terdiri atas 32 siswa (eksperimen dan 32 siswa (kontrol kelas XI IPA di SMA N 2 Ungaran tahun ajaran 2013/2014. Data dianalisis menggunakan uji gain dan uji t. Hasil penelitian menunjukkan adanya peningkatan pemahaman konsep siswa dan hasil belajar kognitif siswa. Berdasarkan hasil analisis dapat disimpulkan bahwa penerapan model pembelajaran Auditory Intellectually Repetition (AIR dalam pembelajaran fisika SMA efektif untuk meningkatkan pemahaman konsep siswa.ABSTRACTThe physics learning on concept of the internal energy was carried out through application of Auditory Intellectually Repetition (AIR learning model. This study aimed to determining the improvement of students’ concept understanding and the effectiveness of Auditory Intellectually Repetition (AIR learning model on students’ understanding of the internal energy concept. The research used educational experiment research with pre test-post test control group design. The subject of research consisted of 32 students in eksperimental group and 32 students in control group of XI IPA SMA N 2 Ungaran, academic year 2013/2014. The data were analyzed by using gain test and t test. The result showed that there was an increase of students’ concept understanding and the outcome of students’ cognitive learning. Based on the result, it can be concluded that the application of Auditory Intellectually Repetition (AIR learning model in

  17. BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy.

    Science.gov (United States)

    Petasecca, M; Loo, K J; Safavi-Naeini, M; Han, Z; Metcalfe, P E; Meikle, S; Pospisil, S; Jakubek, J; Bucci, J A; Zaider, M; Lerch, M L F; Qi, Y; Rosenfeld, A B

    2013-04-01

    The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5-3 mm for a 10-60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for real-time imaging (using a 3 s

  18. BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy

    International Nuclear Information System (INIS)

    Petasecca, M.; Loo, K. J.; Safavi-Naeini, M.; Han, Z.; Metcalfe, P. E.; Lerch, M. L. F.; Qi, Y.; Rosenfeld, A. B.; Meikle, S.; Pospisil, S.; Jakubek, J.; Bucci, J. A.; Zaider, M.

    2013-01-01

    Purpose: The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. Methods: BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. Results: The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5–3 mm for a 10–60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for

  19. Long-term repetition priming with symmetrical polygons and words.

    Science.gov (United States)

    Kersteen-Tucker, Z

    1991-01-01

    In two different tasks, subjects were asked to make lexical decisions (word or nonword) and symmetry judgments (symmetrical or nonsymmetrical) about two-dimensional polygons. In both tasks, every stimulus was repeated at one of four lags (0, 1, 4, or 8 items interposed between the first and second stimulus presentations). This paradigm, known as repetition priming, revealed comparable short-term priming (Lag 0) and long-term priming (Lags 1, 4, and 8) both for symmetrical polygons and for words. A shorter term component (Lags 0 and 1) of priming was observed for nonwords, and only very short-term priming (Lag 0) was observed for nonsymmetrical polygons. These results indicate that response facilitation accruing from repeated exposure can be observed for stimuli that have no preexisting memory representations and suggest that perceptual factors contribute to repetition-priming effects.

  20. Effects of modality and repetition in a continuous recognition memory task: Repetition has no effect on auditory recognition memory.

    Science.gov (United States)

    Amir Kassim, Azlina; Rehman, Rehan; Price, Jessica M

    2018-04-01

    Previous research has shown that auditory recognition memory is poorer compared to visual and cross-modal (visual and auditory) recognition memory. The effect of repetition on memory has been robust in showing improved performance. It is not clear, however, how auditory recognition memory compares to visual and cross-modal recognition memory following repetition. Participants performed a recognition memory task, making old/new discriminations to new stimuli, stimuli repeated for the first time after 4-7 intervening items (R1), or repeated for the second time after 36-39 intervening items (R2). Depending on the condition, participants were either exposed to visual stimuli (2D line drawings), auditory stimuli (spoken words), or cross-modal stimuli (pairs of images and associated spoken words). Results showed that unlike participants in the visual and cross-modal conditions, participants in the auditory recognition did not show improvements in performance on R2 trials compared to R1 trials. These findings have implications for pedagogical techniques in education, as well as for interventions and exercises aimed at boosting memory performance. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Functional role of a highly repetitive DNA sequence in anchorage of the mouse genome.

    Science.gov (United States)

    Neuer-Nitsche, B; Lu, X N; Werner, D

    1988-09-12

    The major portion of the eukaryotic genome consists of various categories of repetitive DNA sequences which have been studied with respect to their base compositions, organizations, copy numbers, transcription and species specificities; their biological roles, however, are still unclear. A novel quality of a highly repetitive mouse DNA sequence is described which points to a functional role: All copies (approximately 50,000 per haploid genome) of this DNA sequence reside on genomic Alu I DNA fragments each associated with nuclear polypeptides that are not released from DNA by proteinase K, SDS and phenol extraction. By this quality the repetitive DNA sequence is classified as a member of the sub-set of DNA sequences involved in tight DNA-polypeptide complexes which have been previously shown to be components of the subnuclear structure termed 'nuclear matrix'. From these results it has to be concluded that the repetitive DNA sequence characterized in this report represents or comprises a signal for a large number of site specific attachment points of the mouse genome in the nuclear matrix.

  2. Differential preparation intervals modulate repetition processes in task switching: an ERP study

    Directory of Open Access Journals (Sweden)

    Min eWang

    2016-02-01

    Full Text Available In task-switching paradigms, reaction times (RTs switch cost (SC and the neural correlates underlying the SC are affected by different preparation intervals. However, little is known about the effect of the preparation interval on the repetition processes in task-switching. To examine this effect we utilized a cued task-switching paradigm with long sequences of repeated trials. Response-stimulus intervals (RSI and cue-stimulus intervals (CSI were manipulated in short and long conditions. Electroencephalography (EEG and behavioral data were recorded. We found that with increasing repetitions, RTs were faster in the short CSI conditions, while P3 amplitudes decreased in the LS (long RSI and short CSI conditions. Positive correlations between RT benefit and P3 activation decrease (repeat 1 minus repeat 5, and between the slope of the RT and P3 regression lines were observed only in the LS condition. Our findings suggest that differential preparation intervals modulate repetition processes in task switching.

  3. Facilitation of speech repetition accuracy by theta burst stimulation of the left posterior inferior frontal gyrus.

    Science.gov (United States)

    Restle, Julia; Murakami, Takenobu; Ziemann, Ulf

    2012-07-01

    The posterior part of the inferior frontal gyrus (pIFG) in the left hemisphere is thought to form part of the putative human mirror neuron system and is assigned a key role in mapping sensory perception onto motor action. Accordingly, the pIFG is involved in motor imitation of the observed actions of others but it is not known to what extent speech repetition of auditory-presented sentences is also a function of the pIFG. Here we applied fMRI-guided facilitating intermittent theta burst transcranial magnetic stimulation (iTBS), or depressant continuous TBS (cTBS), or intermediate TBS (imTBS) over the left pIFG of healthy subjects and compared speech repetition accuracy of foreign Japanese sentences before and after TBS. We found that repetition accuracy improved after iTBS and, to a lesser extent, after imTBS, but remained unchanged after cTBS. In a control experiment, iTBS was applied over the left middle occipital gyrus (MOG), a region not involved in sensorimotor processing of auditory-presented speech. Repetition accuracy remained unchanged after iTBS of MOG. We argue that the stimulation type and stimulation site specific facilitating effect of iTBS over left pIFG on speech repetition accuracy indicates a causal role of the human left-hemispheric pIFG in the translation of phonological perception to motor articulatory output for repetition of speech. This effect may prove useful in rehabilitation strategies that combine repetitive speech training with iTBS of the left pIFG in speech disorders, such as aphasia after cerebral stroke. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. An effective repetitive training schedule to achieve skill proficiency using a novel robotic virtual reality simulator.

    Science.gov (United States)

    Kang, Sung Gu; Ryu, Byung Ju; Yang, Kyung Sook; Ko, Young Hwii; Cho, Seok; Kang, Seok Ho; Patel, Vipul R; Cheon, Jun

    2015-01-01

    A robotic virtual reality simulator (Mimic dV-Trainer) can be a useful training method for the da Vinci surgical system. Herein, we investigate several repetitive training schedules and determine which is the most effective. A total of 30 medical students were enrolled and were divided into 3 groups according to the training schedule. Group 1 performed the task 1 hour daily for 4 consecutive days, group II performed the task on once per week for 1 hour for 4 consecutive weeks, and group III performed the task for 4 consecutive hours in 1 day. The effects of training were investigated by analyzing the number of repetitions and the time required to complete the "Tube 2" simulation task when the learning curve plateau was reached. The point at which participants reached a stable score was evaluated using the cumulative sum control graph. The average time to complete the task at the learning curve plateau was 150.3 seconds in group I, 171.9 seconds in group II, and 188.5 seconds in group III. The number of task repetitions required to reach the learning curve plateau was 45 repetitions in group I, 36 repetitions in group II, and 39 repetitions in group III. Therefore, there was continuous improvement in the time required to perform the task after 40 repetitions in group I only. There was a significant correlation between improvement in each trial interval and attempt, and the correlation coefficient (0.924) in group I was higher than that in group II (0.899) and group III (0.838). Daily 1-hour practice sessions performed for 4 consecutive days resulted in the best final score, continuous score improvement, and effective training while minimizing fatigue. This repetition schedule can be used for effectively training novices in future. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. The Action Plan Against Repetitive Work - An Industrial Relation Strategy for Improving the Working Environment

    DEFF Research Database (Denmark)

    Hasle, Peter; Møller, Niels

    2001-01-01

    The Danish Action Plan against Repetitive Work is presented and discussed as a possible new strategy for regulating repetitive work as well as other complicated working environment problems. The article is based on an empirical evaluation ot the Action Plan. The asseessment of the Action Plan...... indicates that a measurable reduction of repetitive work has been achieved, while recognizing the the new management strategies focusing on human resources development have also played an important role. These results are used to suggest that - under certain conditions - a combination of state regulation...... and industrial relation agreements can be used to regulate other working environment problems....

  6. N-2 repetition leads to a cost within working memory and a benefit outside it.

    Science.gov (United States)

    Kessler, Yoav

    2018-03-15

    Removal has been suggested to play a key role in controlling the contents of working memory. The present study examined the aftereffects of removal in a working memory updating task. Participants performed the reference-back paradigm, a version of the n-back task that is composed of two trial types: reference trials that required working memory updating and comparison trials that did not require updating. N-2 repetition effects-the difference in performance between trials that presented the same stimulus as the one presented two trials before (ABA sequences) and trials in which the stimulus differed from the two previous stimuli (ABC sequences)-were examined. In two experiments, n-2 repetition costs were observed within sequences of reference trials, while n-2 repetition benefits were observed within sequences of comparison trials. This pattern suggests that removal takes place during working memory updating. Furthermore, automatic formation and updating of representation outside working memory, which takes place in comparison trials and gives rise to n-2 repetition benefits, does not involve removal. Removal, demonstrated by phenomena such as n-2 repetition costs, is therefore proposed to be a marker for the utilization of working memory within a given task. © 2018 New York Academy of Sciences.

  7. Working memory load affects repetitive behaviour but not cognitive flexibility in adolescent autism spectrum disorder.

    Science.gov (United States)

    Wolff, Nicole; Chmielewski, Witold X; Beste, Christian; Roessner, Veit

    2017-03-16

    Autism spectrum disorder (ASD) is associated with repetitive and stereotyped behaviour, suggesting that cognitive flexibility may be deficient in ASD. A central, yet not examined aspect to understand possible deficits in flexible behaviour in ASD relates (i) to the role of working memory and (ii) to neurophysiological mechanisms underlying behavioural modulations. We analysed behavioural and neurophysiological (EEG) correlates of cognitive flexibility using a task-switching paradigm with and without working memory load in adolescents with ASD and typically developing controls (TD). Adolescents with ASD versus TD show similar performance in task switching with no memory load, indicating that 'pure' cognitive flexibility is not in deficit in adolescent ASD. However performance during task repetition decreases with increasing memory load. Neurophysiological data reflect the pattern of behavioural effects, showing modulations in P2 and P3 event-related potentials. Working memory demands affect repetitive behaviour while processes of cognitive flexibility are unaffected. Effects emerge due to deficits in preparatory attentional processes and deficits in task rule activation, organisation and implementation of task sets when repetitive behaviour is concerned. It may be speculated that the habitual response mode in ASD (i.e. repetitive behaviour) is particularly vulnerable to additional demands on executive control processes.

  8. The Effect of Rest Interval Length on Repetition Consistency and Perceived Exertion During Near Maximal Loaded Bench Press Sets.

    Science.gov (United States)

    Scudese, Estevão; Willardson, Jeffrey M; Simão, Roberto; Senna, Gilmar; de Salles, Belmiro F; Miranda, Humberto

    2015-11-01

    The purpose of this study was to compare different rest intervals between sets on repetition consistency and ratings of perceived exertion (RPE) during consecutive bench press sets with an absolute 3RM (3 repetition maximum) load. Sixteen trained men (23.75 ± 4.21 years; 74.63 ± 5.36 kg; 175 ± 4.64 cm; bench press relative strength: 1.44 ± 0.19 kg/kg of body mass) attended 4 randomly ordered sessions during which 5 consecutive sets of the bench press were performed with an absolute 3RM load and 1, 2, 3, or 5 minutes of rest interval between sets. The results indicated that significantly greater bench press repetitions were completed with 2, 3, and 5 minutes vs. 1-minute rest between sets (p ≤ 0.05); no significant differences were noted between the 2, 3, and 5 minutes rest conditions. For the 1-minute rest condition, performance reductions (relative to the first set) were observed commencing with the second set; whereas for the other conditions (2, 3, and 5 minutes rest), performance reductions were not evident until the third and fourth sets. The RPE values before each of the successive sets were significantly greater, commencing with the second set for the 1-minute vs. the 3 and 5 minutes rest conditions. Significant increases were also evident in RPE immediately after each set between the 1 and 5 minutes rest conditions from the second through fifth sets. These findings indicate that when utilizing an absolute 3RM load for the bench press, practitioners may prescribe a time-efficient minimum of 2 minutes rest between sets without significant impairments in repetition performance. However, lower perceived exertion levels may necessitate prescription of a minimum of 3 minutes rest between sets.

  9. Exact and conceptual repetition dissociate conceptual memory tests: problems for transfer appropriate processing theory.

    Science.gov (United States)

    McDermott, K B; Roediger, H L

    1996-03-01

    Three experiments examined whether a conceptual implicit memory test (specifically, category instance generation) would exhibit repetition effects similar to those found in free recall. The transfer appropriate processing account of dissociations among memory tests led us to predict that the tests would show parallel effects; this prediction was based upon the theory's assumption that conceptual tests will behave similarly as a function of various independent variables. In Experiment 1, conceptual repetition (i.e., following a target word [e.g., puzzles] with an associate [e.g., jigsaw]) did not enhance priming on the instance generation test relative to the condition of simply presenting the target word once, although this manipulation did affect free recall. In Experiment 2, conceptual repetition was achieved by following a picture with its corresponding word (or vice versa). In this case, there was an effect of conceptual repetition on free recall but no reliable effect on category instance generation or category cued recall. In addition, we obtained a picture superiority effect in free recall but not in category instance generation. In the third experiment, when the same study sequence was used as in Experiment 1, but with instructions that encouraged relational processing, priming on the category instance generation task was enhanced by conceptual repetition. Results demonstrate that conceptual memory tests can be dissociated and present problems for Roediger's (1990) transfer appropriate processing account of dissociations between explicit and implicit tests.

  10. Analysis of repetitive DNA in chromosomes by flow cytometry

    NARCIS (Netherlands)

    Brind'Amour, Julie; Lansdorp, Peter M.

    We developed a flow cytometry method, chromosome flow fluorescence in situ hybridization (FISH), called CFF, to analyze repetitive DNA in chromosomes using FISH with directly labeled peptide nucleic acid (PNA) probes. We used CFF to measure the abundance of interstitial telomeric sequences in

  11. Repetitive motion planning and control of redundant robot manipulators

    CERN Document Server

    Zhang, Yunong

    2013-01-01

    Repetitive Motion Planning and Control of Redundant Robot Manipulators presents four typical motion planning schemes based on optimization techniques, including the fundamental RMP scheme and its extensions. These schemes are unified as quadratic programs (QPs), which are solved by neural networks or numerical algorithms. The RMP schemes are demonstrated effectively by the simulation results based on various robotic models; the experiments applying the fundamental RMP scheme to a physical robot manipulator are also presented. As the schemes and the corresponding solvers presented in the book have solved the non-repetitive motion problems existing in redundant robot manipulators, it is of particular use in applying theoretical research based on the quadratic program for redundant robot manipulators in industrial situations. This book will be a valuable reference work for engineers, researchers, advanced undergraduate and graduate students in robotics fields. Yunong Zhang is a professor at The School of Informa...

  12. Sound segregation via embedded repetition is robust to inattention.

    Science.gov (United States)

    Masutomi, Keiko; Barascud, Nicolas; Kashino, Makio; McDermott, Josh H; Chait, Maria

    2016-03-01

    The segregation of sound sources from the mixture of sounds that enters the ear is a core capacity of human hearing, but the extent to which this process is dependent on attention remains unclear. This study investigated the effect of attention on the ability to segregate sounds via repetition. We utilized a dual task design in which stimuli to be segregated were presented along with stimuli for a "decoy" task that required continuous monitoring. The task to assess segregation presented a target sound 10 times in a row, each time concurrent with a different distractor sound. McDermott, Wrobleski, and Oxenham (2011) demonstrated that repetition causes the target sound to be segregated from the distractors. Segregation was queried by asking listeners whether a subsequent probe sound was identical to the target. A control task presented similar stimuli but probed discrimination without engaging segregation processes. We present results from 3 different decoy tasks: a visual multiple object tracking task, a rapid serial visual presentation (RSVP) digit encoding task, and a demanding auditory monitoring task. Load was manipulated by using high- and low-demand versions of each decoy task. The data provide converging evidence of a small effect of attention that is nonspecific, in that it affected the segregation and control tasks to a similar extent. In all cases, segregation performance remained high despite the presence of a concurrent, objectively demanding decoy task. The results suggest that repetition-based segregation is robust to inattention. (c) 2016 APA, all rights reserved).

  13. Relationship between Subtypes of Restricted and Repetitive Behaviors and Sleep Disturbance in Autism Spectrum Disorder

    Science.gov (United States)

    Hundley, Rachel J.; Shui, Amy; Malow, Beth A.

    2016-01-01

    We examined the association of two types of restricted and repetitive behaviors, repetitive sensory motor (RSM) and insistence on sameness (IS), with sleep problems in children with autism spectrum disorder (ASD). Participants included 532 children (aged 2-17) who participated in the Autism Speaks Autism Treatment Network research registry.…

  14. Ammonia and nitrite removal rates in a closed recirculating-water system, under three load rates of rainbow trout Oncorhynchus mykiss

    OpenAIRE

    Arredondo-Figueroa, J. L.; Ingle de la Mora, G; Guerrero-Legarreta, I; Ponce-Palafox, J. T.; Barriga-Sosa, I. de los A.

    2007-01-01

    Nitrification and denitrification rates of inorganic nitrogen were studied in a closed recirculating-water system, comparing three load rates of rainbow trout Oncorhynchus mykiss (89, 156 and 194 kg in each tank with two repetitions). Six self-cleaning water circular fish tanks with a volume of 4.3 m³ were used, maintaining a 3.94 m³/day of average flow rate and constant aeration. A total of 371 rainbow trout, 524 ± 8 g initial wet weight were introduced in the system and fed with a commercia...

  15. The incident of repetitive demands resolution in consumer affairs: empirical analysis of legal feasibility

    Directory of Open Access Journals (Sweden)

    Lucas do Monte Silva

    2017-05-01

    Full Text Available Faced with the scenario of massification of lawsuits, this article intends to analyze the main arguments and questionings of the demands related to moral damage and health plans, on Santa Catarina’s Court of Justice, in order to analyze the possible application of the incident of repetitive demands resolution of the new Civil Procedure Code. To do so, it will be done, first, an analysis of the current context of the Brazilian judiciary, presenting the context of repetitive demands and massification of contracts and introductory aspects of the incident of repetitive demands resolution. Then it will made be a judicial empirical analysis, quantitative and qualitative, through a case study of Santa Catarina Courts of Justice, conducting an empirical study of cross descriptive analysis of the demands related to the issue highlighted above, in order to demonstrate an 'argumentative radiography’ of the judgments of that Court. The results confirmed the possibility of applying IRDR in repetitive demands relating to subjects of this study, with due legal caution, taking into account the high number of “issues of fact” that involve lawsuits that have, among their claims, compensation for moral damages.

  16. Gating circuit for single photon-counting fluorescence lifetime instruments using high repetition pulsed light sources

    International Nuclear Information System (INIS)

    Laws, W.R.; Potter, D.W.; Sutherland, J.C.

    1984-01-01

    We have constructed a circuit that permits conventional timing electronics to be used in single photon-counting fluorimeters with high repetition rate excitation sources (synchrotrons and mode-locked lasers). Most commercial time-to-amplitude and time-to-digital converters introduce errors when processing very short time intervals and when subjected to high-frequency signals. This circuit reduces the frequency of signals representing the pulsed light source (stops) to the rate of detected fluorescence events (starts). Precise timing between the start/stop pair is accomplished by using the second stop pulse after a start pulse. Important features of our design are that the circuit is insensitive to the simultaneous occurrence of start and stop signals and that the reduction in the stop frequency allows the start/stop time interval to be placed in linear regions of the response functions of commercial timing electronics

  17. Nonword repetition in adults who stutter: The effects of stimuli stress and auditory-orthographic cues.

    Directory of Open Access Journals (Sweden)

    Geoffrey A Coalson

    Full Text Available Adults who stutter (AWS are less accurate in their immediate repetition of novel phonological sequences compared to adults who do not stutter (AWNS. The present study examined whether manipulation of the following two aspects of traditional nonword repetition tasks unmask distinct weaknesses in phonological working memory in AWS: (1 presentation of stimuli with less-frequent stress patterns, and (2 removal of auditory-orthographic cues immediately prior to response.Fifty-two participants (26 AWS, 26 AWNS produced 12 bisyllabic nonwords in the presence of corresponding auditory-orthographic cues (i.e., immediate repetition task, and the absence of auditory-orthographic cues (i.e., short-term recall task. Half of each cohort (13 AWS, 13 AWNS were exposed to the stimuli with high-frequency trochaic stress, and half (13 AWS, 13 AWNS were exposed to identical stimuli with lower-frequency iambic stress.No differences in immediate repetition accuracy for trochaic or iambic nonwords were observed for either group. However, AWS were less accurate when recalling iambic nonwords than trochaic nonwords in the absence of auditory-orthographic cues.Manipulation of two factors which may minimize phonological demand during standard nonword repetition tasks increased the number of errors in AWS compared to AWNS. These findings suggest greater vulnerability in phonological working memory in AWS, even when producing nonwords as short as two syllables.

  18. Chronic repetitive reaching and grasping results in decreased motor performance and widespread tissue responses in a rat model of MSD.

    Science.gov (United States)

    Barbe, Mary F; Barr, Ann E; Gorzelany, Irene; Amin, Mamta; Gaughan, John P; Safadi, Fayez F

    2003-01-01

    This study investigated changes in motor skills and tissues of the upper extremity (UE) with regard to injury and inflammatory reactions resulting from performance of a voluntary forelimb repetitive reaching and grasping task in rats. Rats reached for food at a rate of 4 reaches/min, 2 h/day, and 3 days/week for up to 8 weeks during which reach rate, task duration and movement strategies were observed. UE tissues were collected bilaterally at weekly time points of 3-8 weeks and examined for morphological changes. Serum was tested for levels of interleukin-1alpha (IL-1) protein. The macrophage-specific antibody, ED1, was used to identify infiltrating macrophages and the ED2 antibody was used to identify resident macrophages. Rats were unable to maintain baseline reach rate in weeks 5 and 6 of task performance. Alternative patterns of movement emerged. Fraying of tendon fibrils was observed after 6 weeks in the mid-forelimb. After 4 weeks, a general elevation of ED1-IR macrophages were seen in all tissues examined bilaterally including the contralateral, uninvolved forelimb and hindlimbs. Significantly more resident macrophages were seen at 6 and 8 weeks in the reach limb. At 8 weeks, serum levels of IL-1alpha increased significantly above week 0. Our results demonstrate that performance of repetitive tasks elicits motor decrements, signs of injury and a cellular and tissue responses associated with inflammation.

  19. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function

    NARCIS (Netherlands)

    Coolen, Bram F.; Abdurrachim, Desiree; Motaal, Abdallah G.; Nicolay, Klaas; Prompers, Jeanine J.; Strijkers, Gustav J.

    2013-01-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered

  20. The Effect of Repetition on Tempo Preferences of Elementary Children.

    Science.gov (United States)

    Moskovitz, Elisa M.

    1992-01-01

    Reports on a study of children's preferences between slow and fast tempo classical music excerpts. Finds that students preferred music with a slow tempo. Concludes that repetition had a positive effect on children's preferences. (CFR)