WorldWideScience

Sample records for repeated measures study

  1. Methods for analysing cardiovascular studies with repeated measures

    NARCIS (Netherlands)

    Cleophas, T. J.; Zwinderman, A. H.; van Ouwerkerk, B. M.

    2009-01-01

    Background. Repeated measurements in a single subject are generally more similar than unrepeated measurements in different subjects. Unrepeated analyses of repeated data cause underestimation of the treatment effects. Objective. To review methods adequate for the analysis of cardiovascular studies

  2. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  3. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    Science.gov (United States)

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  4. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  6. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.; Maity, A.; Mammen, E.; Yu, K.

    2009-01-01

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements

  7. Intra-examiner repeatability and agreement in accommodative response measurements.

    Science.gov (United States)

    Antona, B; Sanchez, I; Barrio, A; Barra, F; Gonzalez, E

    2009-11-01

    Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods. The AR of the right eye at one accommodative demand of 2.50 D (40 cm) was measured on two separate occasions in 61 visually normal subjects of mean age 19.7 years (range 18-32 years). The intraexaminer repeatability of the tests, and agreement between them, were estimated by the Bland-Altman method. We determined mean differences (MD) and the 95% limits of agreement [coefficient of repeatability (COR) and coefficient of agreement (COA)]. Nott retinoscopy and BCC offered the best repeatability, showing the lowest MD and narrowest 95% interval of agreement (Nott: -0.10 +/- 0.66 D, BCC: -0.05 +/- 0.75 D). The 95% limits of agreement for the four techniques were similar (COA = +/- 0.92 to +/-1.00 D) yet clinically significant, according to the expected values of the AR. The two dynamic retinoscopy techniques (Nott and MEM) had a better agreement (COA = +/-0.64 D) although this COA must be interpreted in the context of the low MEM repeatability (COR = +/-0.98 D). The best method of assessing AR was Nott retinoscopy. The BCC technique was also repeatable, and both are recommended as suitable methods for clinical use. Despite better agreement between MEM and Nott, agreement among the remaining methods was poor such that their interchangeable use in clinical practice is not recommended.

  8. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  9. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  10. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  11. The effect of repeated applanation on subsequent IOP measurements.

    Science.gov (United States)

    AlMubrad, Turki M; Ogbuehi, Kelechi C

    2008-11-01

    In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (pcontact tonometer in both sessions. These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.

  12. Education for patients with chronic kidney disease in Taiwan: a prospective repeated measures study.

    Science.gov (United States)

    Yen, Miaofen; Huang, Jeng-Jong; Teng, Hsiu-Lan

    2008-11-01

    To investigate the physical, knowledge and quality of life outcomes of an educational intervention for patients with early stage chronic kidney disease. A comprehensive predialysis education care team can be effective in slowing the progression of chronic kidney disease. A single group repeated measures design was used to evaluate the effects of the intervention. Participants were recruited through health department community health screen data banks. A predialysis, team-delivered educational intervention covering renal function health care, dietary management of renal function and the effects of Chinese herb medication on renal function was designed and implemented. Data were collected at baseline, six and 12 months. Study outcomes included physical indicators, knowledge (renal function protection, use of Chinese herbs and renal function and diet) and quality of life. Data were analysed using repeated measure anova to test for change over time in outcome variables. Sixty-six persons participated in this study. The predialysis educational intervention showed significant differences at the three time points in overall knowledge scores, waist-hip ratio, body mass index and global health status. Knowledge measures increased at month 6 and decreased at month 12. The primary indicator of renal function, glomerular filtration rate, remained stable throughout the 12 months of follow-up, despite the relatively older mean age of study participants. A predialysis education care team can provide effective disease-specific knowledge and may help retard deterioration of renal function in persons with early-stage chronic kidney disease. The intervention dose may need to be repeated every six months to maintain knowledge effects. A predialysis educational program with disease-specific knowledge and information is feasible and may provide positive outcomes for patients. Topics on the uses of Chinese herbs should be included for people who are likely to use alternative therapies.

  13. Repeatability of Objective Measurements of Linear Udder and Body ...

    African Journals Online (AJOL)

    The objective of this study was to estimates the repeatability of objective measurements on linear udder and body conformation traits and to evaluate the objectivity of the measurements in Friesian x Bunaji cows. Data from 50 (F1) Frisian X Bunaji cows collected between 2007 and 2008 at the Dairy Research Farm of the ...

  14. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  15. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  16. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  17. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  18. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  19. On model selections for repeated measurement data in clinical studies.

    Science.gov (United States)

    Zou, Baiming; Jin, Bo; Koch, Gary G; Zhou, Haibo; Borst, Stephen E; Menon, Sandeep; Shuster, Jonathan J

    2015-05-10

    Repeated measurement designs have been widely used in various randomized controlled trials for evaluating long-term intervention efficacies. For some clinical trials, the primary research question is how to compare two treatments at a fixed time, using a t-test. Although simple, robust, and convenient, this type of analysis fails to utilize a large amount of collected information. Alternatively, the mixed-effects model is commonly used for repeated measurement data. It models all available data jointly and allows explicit assessment of the overall treatment effects across the entire time spectrum. In this paper, we propose an analytic strategy for longitudinal clinical trial data where the mixed-effects model is coupled with a model selection scheme. The proposed test statistics not only make full use of all available data but also utilize the information from the optimal model deemed for the data. The performance of the proposed method under various setups, including different data missing mechanisms, is evaluated via extensive Monte Carlo simulations. Our numerical results demonstrate that the proposed analytic procedure is more powerful than the t-test when the primary interest is to test for the treatment effect at the last time point. Simulations also reveal that the proposed method outperforms the usual mixed-effects model for testing the overall treatment effects across time. In addition, the proposed framework is more robust and flexible in dealing with missing data compared with several competing methods. The utility of the proposed method is demonstrated by analyzing a clinical trial on the cognitive effect of testosterone in geriatric men with low baseline testosterone levels. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements.

    Science.gov (United States)

    Preis, Sarah Rosner; Spiegelman, Donna; Zhao, Barbara Bojuan; Moshfegh, Alanna; Baer, David J; Willett, Walter C

    2011-03-15

    Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (ρ) and deattenuation factor (λ), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure to account for within-person variation in biomarkers can exaggerate correlated errors between FFQs and 24-hour diet recalls. For 2 validation studies, ρ and λ were calculated for total energy and protein density. In the Automated Multiple-Pass Method Validation Study (n=471), doubly labeled water (DLW) and urinary nitrogen (UN) were measured twice in 52 adults approximately 16 months apart (2002-2003), yielding intraclass correlation coefficients of 0.43 for energy (DLW) and 0.54 for protein density (UN/DLW). The deattenuated correlation coefficient for protein density was 0.51 for correlation between the FFQ and the 24-hour diet recall and 0.49 for correlation between the FFQ and the biomarker. Use of repeat-biomarker measurement error models resulted in a ρ of 0.42. These models were similarly applied to the Observing Protein and Energy Nutrition Study (1999-2000). In conclusion, within-person variation in biomarkers can be substantial, and to adequately assess the impact of correlated subject-specific error, this variation should be assessed in validation studies of FFQs. © The Author 2011. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved.

  1. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  2. Joint modelling of repeated measurement and time-to-event data: an introductory tutorial.

    Science.gov (United States)

    Asar, Özgür; Ritchie, James; Kalra, Philip A; Diggle, Peter J

    2015-02-01

    The term 'joint modelling' is used in the statistical literature to refer to methods for simultaneously analysing longitudinal measurement outcomes, also called repeated measurement data, and time-to-event outcomes, also called survival data. A typical example from nephrology is a study in which the data from each participant consist of repeated estimated glomerular filtration rate (eGFR) measurements and time to initiation of renal replacement therapy (RRT). Joint models typically combine linear mixed effects models for repeated measurements and Cox models for censored survival outcomes. Our aim in this paper is to present an introductory tutorial on joint modelling methods, with a case study in nephrology. We describe the development of the joint modelling framework and compare the results with those obtained by the more widely used approaches of conducting separate analyses of the repeated measurements and survival times based on a linear mixed effects model and a Cox model, respectively. Our case study concerns a data set from the Chronic Renal Insufficiency Standards Implementation Study (CRISIS). We also provide details of our open-source software implementation to allow others to replicate and/or modify our analysis. The results for the conventional linear mixed effects model and the longitudinal component of the joint models were found to be similar. However, there were considerable differences between the results for the Cox model with time-varying covariate and the time-to-event component of the joint model. For example, the relationship between kidney function as measured by eGFR and the hazard for initiation of RRT was significantly underestimated by the Cox model that treats eGFR as a time-varying covariate, because the Cox model does not take measurement error in eGFR into account. Joint models should be preferred for simultaneous analyses of repeated measurement and survival data, especially when the former is measured with error and the association

  3. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  4. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  5. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  6. Repeatability of Lucas chamber measurements; Powtarzalnosc pomiarow za pomoca komory Lucasa

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.

    1997-12-31

    Results of investigations concerning the repeatability of the measurements carried out with Lucas chamber are presented in the report. The Lucas chamber is used for determination of radon concentration in air, and the Lucas chamber itself is measured in a laboratory stand. The repeatability of measurements is {+-}5.4% relative. The error due to instability of measuring channel gain is estimated to be 2-3% relative. (author). 5 refs, 17 figs, 5 tabs.

  7. Near-Peer Teaching in Paramedic Education: A Repeated Measures Design

    Science.gov (United States)

    Williams, Brett; Nguyen, David

    2017-01-01

    The transition of the Australian paramedic discipline from vocation education and training to the higher education sector has seen a sharp rise in interest in near-peer teaching (NPT). The objective of this study was to examine satisfaction levels of NPT over one academic semester among undergraduate paramedic students. A repeated measured design…

  8. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  9. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  10. Repeatability study of replicate crash tests: A signal analysis approach.

    Science.gov (United States)

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test

  11. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  12. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  13. High precision measurement of the micro-imaging system to check repeatability of precision

    International Nuclear Information System (INIS)

    Cheng Lin; Song Li; Ma Chuntao; Luo Hongxin; Wang Jie

    2010-01-01

    The beamlines slits of Shanghai Synchrotron Radiation Facility (SSRF) are required to have a repeatability of better than 1 μm. Before the slits installation, the off-line and/or on-line repeatability measurements must be conducted. A machine vision measuring system based on high resolution CCD and adjustable high magnification lens was used in this regard. A multi-level filtering method was used to treat the imaging data. After image binarization, the imaging noises were depressed effectively by using of algebraic mean filtering, statistics median filtering,and the least square filtering. Using the subtracted image between the images before and after slit movement, an average displacement of slit blades could be obtained, and the repeatability of slit could be measured, with a resolution of 0.3 μm of the measurement system. The experimental results show that this measurement system meets the requirements for non-contact measurements to the repeatability of slits. (authors)

  14. Unitarity, Feedback, Interactions - Dynamics Emergent from Repeated Measurements

    Science.gov (United States)

    Corona Ugalde, Paulina; Altamirano, Natacha; Mann, Robert; Zych, Magdalena

    Modern measurement theory dispenses with the description of a measurement as a projection. Rather, the measurement is understood as an operation, whereby the system's final state is determined by an action of a completely positive trace non-increasing map and the outcomes are described by linear operators on the system, distributed according to a positive-operator valued measure (POVM). The POVM approach unifies the theory of measurements with a general description of dynamics, the theory of open quantum systems. Engineering a particular measurement and engineering a particular dynamics for the system are thus two complementary aspects of the same conceptual framework. This correspondence is directly applied in quantum simulations and quantum control theory . With this motivation, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence. For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions. The simple framework used in the present study can find applications in devising novel quantum control protocols, or quantum simulations.

  15. Analysis of repeated measurement data in the clinical trials

    Science.gov (United States)

    Singh, Vineeta; Rana, Rakesh Kumar; Singhal, Richa

    2013-01-01

    Statistics is an integral part of Clinical Trials. Elements of statistics span Clinical Trial design, data monitoring, analyses and reporting. A solid understanding of statistical concepts by clinicians improves the comprehension and the resulting quality of Clinical Trials. In biomedical research it has been seen that researcher frequently use t-test and ANOVA to compare means between the groups of interest irrespective of the nature of the data. In Clinical Trials we record the data on the patients more than two times. In such a situation using the standard ANOVA procedures is not appropriate as it does not consider dependencies between observations within subjects in the analysis. To deal with such types of study data Repeated Measure ANOVA should be used. In this article the application of One-way Repeated Measure ANOVA has been demonstrated by using the software SPSS (Statistical Package for Social Sciences) Version 15.0 on the data collected at four time points 0 day, 15th day, 30th day, and 45th day of multicentre clinical trial conducted on Pandu Roga (~Iron Deficiency Anemia) with an Ayurvedic formulation Dhatrilauha. PMID:23930038

  16. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  17. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  18. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  19. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  20. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  1. On summary measure analysis of linear trend repeated measures data: performance comparison with two competing methods.

    Science.gov (United States)

    Vossoughi, Mehrdad; Ayatollahi, S M T; Towhidi, Mina; Ketabchi, Farzaneh

    2012-03-22

    The summary measure approach (SMA) is sometimes the only applicable tool for the analysis of repeated measurements in medical research, especially when the number of measurements is relatively large. This study aimed to describe techniques based on summary measures for the analysis of linear trend repeated measures data and then to compare performances of SMA, linear mixed model (LMM), and unstructured multivariate approach (UMA). Practical guidelines based on the least squares regression slope and mean of response over time for each subject were provided to test time, group, and interaction effects. Through Monte Carlo simulation studies, the efficacy of SMA vs. LMM and traditional UMA, under different types of covariance structures, was illustrated. All the methods were also employed to analyze two real data examples. Based on the simulation and example results, it was found that the SMA completely dominated the traditional UMA and performed convincingly close to the best-fitting LMM in testing all the effects. However, the LMM was not often robust and led to non-sensible results when the covariance structure for errors was misspecified. The results emphasized discarding the UMA which often yielded extremely conservative inferences as to such data. It was shown that summary measure is a simple, safe and powerful approach in which the loss of efficiency compared to the best-fitting LMM was generally negligible. The SMA is recommended as the first choice to reliably analyze the linear trend data with a moderate to large number of measurements and/or small to moderate sample sizes.

  2. Comparability and repeatability of three commonly used methods for measuring endurance capacity.

    Science.gov (United States)

    Baxter-Gilbert, James; Mühlenhaupt, Max; Whiting, Martin J

    2017-12-01

    Measures of endurance (time to exhaustion) have been used to address a wide range of questions in ecomorphological and physiological research, as well as being used as a proxy for survival and fitness. Swimming, stationary (circular) track running, and treadmill running are all commonly used methods for measuring endurance. Despite the use of these methods across a broad range of taxa, how comparable these methods are to one another, and whether they are biologically relevant, is rarely examined. We used Australian water dragons (Intellagama lesueurii), a species that is morphologically adept at climbing, swimming, and running, to compare these three methods of endurance and examined if there is repeatability within and between trial methods. We found that time to exhaustion was not highly repeatable within a method, suggesting that single measures or a mean time to exhaustion across trials are not appropriate. Furthermore, we compared mean maximal endurance times among the three methods, and found that the two running methods (i.e., stationary track and treadmill) were similar, but swimming was distinctly different, resulting in lower mean maximal endurance times. Finally, an individual's endurance rank was not repeatable across methods, suggesting that the three endurance trial methods are not providing similar information about an individual's performance capacity. Overall, these results highlight the need to carefully match a measure of performance capacity with the study species and the research questions being asked so that the methods being used are behaviorally, ecologically, and physiologically relevant. © 2018 Wiley Periodicals, Inc.

  3. Parsimonious Structural Equation Models for Repeated Measures Data, with Application to the Study of Consumer Preferences

    Science.gov (United States)

    Elrod, Terry; Haubl, Gerald; Tipps, Steven W.

    2012-01-01

    Recent research reflects a growing awareness of the value of using structural equation models to analyze repeated measures data. However, such data, particularly in the presence of covariates, often lead to models that either fit the data poorly, are exceedingly general and hard to interpret, or are specified in a manner that is highly data…

  4. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate b...

  5. Validation of Repeated Endothelial Function Measurements Using EndoPAT in Stroke

    DEFF Research Database (Denmark)

    Hansen, Aina S; Butt, Jawad H; Holm-Yildiz, Sonja

    2017-01-01

    BACKGROUND: Decreased endothelial function (EF) may be a prognostic marker for stroke. Measuring pharmacological effects on EF may be of interest in the development of personalized medicine for stroke prevention. In this study, we assessed the reliability of repeated EF measurements using a pulse......%, mean age 35.85 ± 3.47 years) and 21 stroke patients (men 52%, mean age 66.38 ± 2.85 years, and mean NIHSS 4.09 ± 0.53) under standardized conditions. EF was measured as the reactive hyperemia index (RHI), logarithm of RHI (lnRHI), and Framingham RHI (fRHI). Measurements were separated by 1.5 and 24 h...

  6. Convergence of repeated quantum nondemolition measurements and wave-function collapse

    International Nuclear Information System (INIS)

    Bauer, Michel; Bernard, Denis

    2011-01-01

    Motivated by recent experiments on quantum trapped fields, we give a rigorous proof that repeated indirect quantum nondemolition (QND) measurements converge to the collapse of the wave function as predicted by the postulates of quantum mechanics for direct measurements. We also relate the rate of convergence toward the collapsed wave function to the relative entropy of each indirect measurement, a result which makes contact with information theory.

  7. A study on radiographic repeat rate data of several hospitals in Jeddah

    International Nuclear Information System (INIS)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A.

    2003-01-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m 2 . As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  8. A study on radiographic repeat rate data of several hospitals in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A

    2003-07-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m{sup 2}. As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  9. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  10. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...... to sphericity assumptions, use of F tests and the Greenhouse-Geisser and Huynh-Feldt adjustments to compensate for deviations from sphericity. During a recent implementation of such methods in the R language, the general structure of such transformations was reconsidered, leading to a flexible specification...

  11. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    Science.gov (United States)

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations

  12. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  13. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  14. Effect of hip braces on brake response time: Repeated measures designed study.

    Science.gov (United States)

    Dammerer, Dietmar; Waidmann, Cornelia; Huber, Dennis G; Krismer, Martin; Haid, Christian; Liebensteiner, Michael C

    2017-08-01

    The question whether or not a patient with a hip brace should drive a car is of obvious importance because the advice given to patients to resume driving is often anecdotal as few scientific data are available on this specific subject. To assess driving ability (brake response time) with commonly used hip braces. Repeated measures design. Brake response time was assessed under six conditions: (1) without a brace (control), (2) with a typical postoperative hip brace with adjustable range of motion and the settings: unrestricted, (3) flexion limited to 70°, (4) extension blocked at 20° hip flexion, (5) both flexion and extension limited (20°/70°) and (6) an elastic hip bandage. Brake response time was assessed using a custom-made driving simulator as used in previous studies. The participants were a convenience sample of able-bodied participants. A total of 70 participants (35 women and 35 men) participated in our study. Mean age was 31.1 (standard deviation: 10.6; range: 21.7-66.4) years. A significant within-subject effect for brake response time was found ( p = 0.009), but subsequent post hoc analyses revealed no significant differences between control and the other settings. Based on our findings, it does not seem mandatory to recommend driving abstinence for patients wearing a hip orthosis. We suggest that our results be interpreted with caution, because (1) an underlying pathological hip condition needs to be considered, (2) the ability to drive a car safely is multifactorial and brake response time is only one component thereof and (3) brake response time measurements were performed only with healthy participants. Clinical relevance Hip braces are used in the context of joint-preserving and prosthetic surgery of the hip. Therefore, clinicians are confronted with the question whether to allow driving a car with the respective hip brace or not. Our data suggest that hip braces do not impair brake response time.

  15. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  16. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  17. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  18. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Science.gov (United States)

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  19. Intelligence is in the eye of the beholder: investigating repeated IQ measurements in forensic psychiatry.

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-05-01

    A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were computed, and each IQ score was categorized. Additionally, t-tests and regression analyses were performed. Differences of 10 points or more were found in 66% of the cases comparing WAIS-III with RAVEN scores. Fisher's exact test revealed differences between two WAIS-III scores and the WAIS categories. The WAIS-III did not predict other IQs (WAIS or RAVEN) in participants with intellectual disability. This study showed that stability or interchangeability of scores is lacking, especially in individuals with intellectual disability. Caution in interpreting IQ scores is therefore recommended, and the use of the unitary concept of IQ should be discouraged. © 2014 John Wiley & Sons Ltd.

  20. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study.

    Science.gov (United States)

    Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S; Cohen, Allison; Coull, Brent A; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A; Li, Yongsheng; Stone, Peter H; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R

    2014-03-01

    Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Baseline BAD was negatively associated with particle pollution, including home/trip-integrated BC (-0.02 mm; 95% CI: -0.04, -0.003, for a 0.28 μg/m3 increase in BC), OC (-0.08 mm; 95% CI: -0.14, -0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Zanobetti A, Luttmann

  1. Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

    Directory of Open Access Journals (Sweden)

    Adrian F. Ocneanu

    2017-01-01

    Full Text Available Purpose. Myocardial blood flow (MBF quantification with Rb82 positron emission tomography (PET is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic Rb82 PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1 blood-pool versus uptake region sampled input function (Blood/Uptake-ROI, (2 dual spillover correction (SOC-On/Off, (3 right blood correction (RBC-On/Off, (4 arterial blood transit delay (Delay-On/Off, and (5 distribution volume (DV constraint (Global/Regional-DV. Repeatability of MBF, stress/rest myocardial flow reserve (MFR, and stress/rest MBF difference (ΔMBF was assessed using nonparametric reproducibility coefficients (RPCnp = 1.45 × interquartile range. Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPCnp = 0.21 mL/min/g (15.8%. Corresponding MFR and ΔMBF RPCnp were 0.42 (20.2% and 0.24 mL/min/g (23.5%. MBF repeatability improved with SOC-On at stress (p<0.001 and tended to improve with RBC-Off at both rest and stress (p<0.08. DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.

  2. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  3. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  4. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK

    Directory of Open Access Journals (Sweden)

    Rosa Weiss Telles

    Full Text Available Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK. Material and methods: A test–retest design including 19 adults (38 knee images was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD values. Repeatability was assessed for IMD and joint space width (JSW measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively. Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV = 54.68%; intraclass correlation coefficient (ICC (95%CI = 0.59 (0.34–0.77]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI = 0.74 (0.55–0.85–0.94 (0.87–0.97]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.

  5. Use of the Counseling Center Assessment of Psychological Symptoms 62 (CCAPS-62) as a Repeated Measure

    Science.gov (United States)

    Ghosh, Arpita; Rieder Bennett, Sara; Martin, Juanita K.

    2018-01-01

    The purpose of this initial, exploratory study was to examine the utility of the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62) as a repeated measure tool at one university counseling center. This study investigated whether clients engaged in individual counseling changed in symptomology while in treatment and when (e.g.,…

  6. Ocular surface sensitivity repeatability with Cochet-Bonnet esthesiometer.

    Science.gov (United States)

    Chao, Cecilia; Stapleton, Fiona; Badarudin, Ezailina; Golebiowski, Blanka

    2015-02-01

    To determine the repeatability of ocular surface threshold measurements using the Cochet-Bonnet esthesiometer on the same day and 3 months apart. Two separate studies were conducted to determine the repeatability of ocular surface threshold measurements made on the same day (n = 20 subjects) and 3 months apart (n = 29 subjects). The Cochet-Bonnet esthesiometer was used to measure corneal and inferior conjunctival thresholds using the ascending method of limits. The pressure exerted by the Cochet-Bonnet esthesiometer was determined using an analytical balance, for both the 0.08- and 0.12-mm-diameter filaments. This calibration was then used to convert filament length measurements to pressure. Repeatability was determined using a Bland and Altman analysis. The pressure exerted at each filament length differed between the two filament diameters. The measured pressure also differed from values provided by the manufacturer. Repeatability of threshold measurements at the central cornea was shown to be good, with better repeatability for same-day measurements (coefficient of repeatability [CoR] = ±0.23 g/mm²) than for those 3 months apart (CoR = ±0.52 g/mm²). Threshold measurements at the inferior conjunctiva, in contrast, were poorly repeatable (CoR = ±12.78 g/mm²). Cochet-Bonnet esthesiometry is repeatable when performed on the central cornea on the same day and 3 months apart, but this instrument is not recommended for conjunctival threshold measurements.

  7. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  8. Short-term Changes of Apparent Optical Properties in a Shallow Water Environment: Observations from Repeated Airborne Hyperspectral Measurements

    Science.gov (United States)

    Zhang, M.; English, D. C.; Hu, C.; Carlson, P. R., Jr.; Muller-Karger, F. E.; Toro-Farmer, G.; Herwitz, S. R.

    2016-02-01

    An atmospheric correction algorithm has been developed for AISA imagery over optically shallow waters in Sugarloaf Key of the Florida Keys. The AISA data were collected repeatedly during several days in May 2012, October 2012, and May 2013. A non-zero near-infrared (NIR) remote sensing reflectance (Rrs) was accounted for through iterations, based on the relationship of field-measured Rrs between the NIR and red wavelengths. Validation showed mean ratios of 0.94 to 1.002 between AISA-derived and field-measured Rrs in the blue to red wavelengths, with uncertainties generally turbidity (light attenuation) and bottom contributions. Some of these changes are larger than two times of the Rrs uncertainties from the AISA retrievals, therefore representing statistically significant changes that can be well observed from airborne measurements. The case study suggests that repeated airborne measurements may be used to study short-term changes in shallow water environments, and such a capacity may be enhanced with future geostationary satellite missions specifically designed to observe coastal ecosystems.

  9. REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

    Energy Technology Data Exchange (ETDEWEB)

    Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa [Spitzer Science Center, California Institute of Technology, 1200 E California Boulevard, Mail Code 314-6, Pasadena, CA 91125 (United States); Buzasi, Derek [Department of Chemistry and Physics, Florida Gulf Coast University, Fort Myers, FL 33965 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Diamond-Lowe, Hannah; Stevenson, Kevin B. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S Ellis Avenue, Chicago, IL 60637 (United States); Evans, Thomas M. [School of Physics, University of Exeter, EX4 4QL Exeter (United Kingdom); Morello, G. [Department of Physics and Astronomy, University College London, Gower Street, WC1 E6BT (United Kingdom); Wong, Ian, E-mail: ingalls@ipac.caltech.edu [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-08-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble,  5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

  10. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    International Nuclear Information System (INIS)

    Kroner, E; Arzt, E; Maboudian, R

    2009-01-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  11. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  13. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  14. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy.

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-07-01

    To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.

  15. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  16. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  17. Formatting data files for repeated-measures analyses in SPSS: Using the Aggregate and Restructure procedures

    Directory of Open Access Journals (Sweden)

    Gyslain Giguère

    2006-03-01

    Full Text Available In this tutorial, we demonstrate how to use the Aggregate and Restructure procedures available in SPSS (versions 11 and up to prepare data files for repeated-measures analyses. In the first two sections of the tutorial, we briefly describe the Aggregate and Restructure procedures. In the final section, we present an example in which the data from a fictional lexical decision task are prepared for analysis using a mixed-design ANOVA. The tutorial demonstrates that the presented method is the most efficient way to prepare data for repeated-measures analyses in SPSS.

  18. Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.

    Science.gov (United States)

    Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E

    2018-01-01

    The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established

  19. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  20. PET functional volume delineation: a robustness and repeatability study

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Cheze-le Rest, Catherine; Albarghach, Nidal; Pradier, Olivier; Visvikis, Dimitris

    2011-01-01

    Current state-of-the-art algorithms for functional uptake volume segmentation in PET imaging consist of threshold-based approaches, whose parameters often require specific optimization for a given scanner and associated reconstruction algorithms. Different advanced image segmentation approaches previously proposed and extensively validated, such as among others fuzzy C-means (FCM) clustering, or fuzzy locally adaptive bayesian (FLAB) algorithm have the potential to improve the robustness of functional uptake volume measurements. The objective of this study was to investigate robustness and repeatability with respect to various scanner models, reconstruction algorithms and acquisition conditions. Robustness was evaluated using a series of IEC phantom acquisitions carried out on different PET/CT scanners (Philips Gemini and Gemini Time-of-Flight, Siemens Biograph and GE Discovery LS) with their associated reconstruction algorithms (RAMLA, TF MLEM, OSEM). A range of acquisition parameters (contrast, duration) and reconstruction parameters (voxel size) were considered for each scanner model, and the repeatability of each method was evaluated on simulated and clinical tumours and compared to manual delineation. For all the scanner models, acquisition parameters and reconstruction algorithms considered, the FLAB algorithm demonstrated higher robustness in delineation of the spheres with low mean errors (10%) and variability (5%), with respect to threshold-based methodologies and FCM. The repeatability provided by all segmentation algorithms considered was very high with a negligible variability of <5% in comparison to that associated with manual delineation (5-35%). The use of advanced image segmentation algorithms may not only allow high accuracy as previously demonstrated, but also provide a robust and repeatable tool to aid physicians as an initial guess in determining functional volumes in PET. (orig.)

  1. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  2. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  3. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  4. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-01-01

    Purpose To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. Methods Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). Results For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Conclusions Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions. PMID:28738413

  5. Comparison of diet measures from a food-frequency questionnaire with measures from repeated 24-hour dietary recalls. The Norwegian Women and Cancer Study.

    Science.gov (United States)

    Hjartåker, Anette; Andersen, Lene Frost; Lund, Eiliv

    2007-10-01

    To compare diet measures from a food-frequency questionnaire (FFQ) with measures from 24-hour dietary recalls (24HDRs). The participants answered an FFQ after completing four, repeated 24HDRs during a year. Norway, nationwide. Of 500 women randomly selected from The Norwegian Women and Cancer Study (the Norwegian arm of the European Prospective Investigation into Cancer and Nutrition), 286 agreed to participate and 238 completed the study. On the group level, the FFQ overestimated absolute intake in seven and underestimated intake in six of 21 food groups. Intakes of energy, fat, added sugar and alcohol were lower in the FFQ than in the 24HDRs, whereas intake of fibre was higher. Spearman's rank correlation coefficient ranged from 0.13 (desserts) to 0.82 (coffee) for foods, and from 0.25 (beta-carotene) to 0.67 (alcohol) for nutrients. Three per cent of the observations on nutrient intake fell in the opposite quintile when classified according to the FFQ as compared with the 24HDR. The median calibration coefficient, calculated by regression of the 24HDR data on the FFQ data, was 0.57 for foods and 0.38 for nutrients. The FFQ's ability to rank subjects was good for foods eaten frequently and fairly good for macronutrients in terms of energy percentages. Weaker ranking abilities were seen for foods eaten infrequently and for some micronutrients. The results underline the necessity of performing measurement error corrections.

  6. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  7. Psychosocial outcomes of Hong Kong Chinese diagnosed with acute coronary syndromes: a prospective repeated measures study.

    Science.gov (United States)

    Chan, Dominic S K; Chau, Janita P C; Chang, Anne M

    2007-08-01

    Western studies have suggested that emotional stress and distress impacted on the morbidity and mortality in people following acute coronary events. Symptoms of anxiety and depression have been associated with re-infarction and death, prolonged recovery and disability and depression may precipitate the client's low self-esteem. This study examined perceived anxiety, depression and self-esteem of Hong Kong Chinese clients diagnosed with acute coronary syndrome (ACS) over a 6-month period following hospital admission. To examine: A prospective, repeated measures design with measures taken on two occasions over a 6-month period; (1) within the 1st week of hospital admission following the onset of ACS and (2) at 6 months follow up. Convenient sample of 182 voluntary consented clients admitted with ACS to a major public hospital in Hong Kong who could communicate in Chinese, complete questionnaires, cognitive intact, and were haemodynamically stable and free from acute chest pain at the time of interview. Baseline data were obtained within 1 week after hospital admission. The follow-up data was collected 6 months after hospital discharge. The Chinese version of the Hospital Anxiety and Depression Scale (HADS), State Self-esteem Scale (SSES), and Rosenberg's Self-Esteem Scale (RSES) were used to assess anxiety and depression, state self-esteem, and trait self-esteem, respectively. Findings suggested gender differences in clients' perception in anxiety, depression and self-esteem. Improvements in clients' perception of these variables were evident over the 6-month period following their acute coronary events. The study confirmed the western notion that psychosocial problems are common among coronary clients and this also applies to Hong Kong Chinese diagnosed with ACS. Further studies to explore effective interventions to address these psychosocial issues are recommended.

  8. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Context matters! sources of variability in weekend physical activity among families: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Robert J. Noonan

    2017-04-01

    Full Text Available Abstract Background Family involvement is an essential component of effective physical activity (PA interventions in children. However, little is known about the PA levels and characteristics of PA among families. This study used a repeated measures design and multiple data sources to explore the variability and characteristics of weekend PA among families. Methods Families (including a ‘target’ child aged 9–11 years, their primary caregiver(s and siblings aged 6–8 years were recruited through primary schools in Liverpool, UK. Participants completed a paper-based PA diary and wore an ActiGraph GT9X accelerometer on their left wrist for up to 16 weekend days. ActiGraph.csv files were analysed using the R-package GGIR version 1.1–4. Mean minutes of moderate-to-vigorous PA (MVPA for each weekend of measurement were calculated using linear mixed models, and variance components were estimated for participant (inter-individual, weekend of measurement, and residual error (intra-individual. Intraclass correlation coefficients (ICC were calculated from the proportion of total variance accounted for by inter-individual sources, and used as a measure of reliability. Diary responses were summed to produce frequency counts. To offer contextual insight into weekend PA among family units, demographic, accelerometer, and diary data were combined to form two case studies representative of low and high active families. Results Twenty-five participants from 7 families participated, including 7 ‘target’ children (mean age 9.3 ± 1.1 years, 4 boys, 6 siblings (mean age 7.2 ± 0.7 years; 4 boys and 12 adults (7 mothers and 5 fathers. There was a high degree of variability in target children’s (ICC = 0.55, siblings (ICC = 0.38, and mothers’ MVPA (ICC = 0.58, but not in fathers’ MVPA (ICC = 0.83. Children’s weekend PA was mostly unstructured in nature and undertaken with friends, whereas a greater proportion of parents’ weekend

  10. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind

  11. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  12. Analyzing Repeated Measures Marginal Models on Sample Surveys with Resampling Methods

    Directory of Open Access Journals (Sweden)

    James D. Knoke

    2005-12-01

    Full Text Available Packaged statistical software for analyzing categorical, repeated measures marginal models on sample survey data with binary covariates does not appear to be available. Consequently, this report describes a customized SAS program which accomplishes such an analysis on survey data with jackknifed replicate weights for which the primary sampling unit information has been suppressed for respondent confidentiality. First, the program employs the Macro Language and the Output Delivery System (ODS to estimate the means and covariances of indicator variables for the response variables, taking the design into account. Then, it uses PROC CATMOD and ODS, ignoring the survey design, to obtain the design matrix and hypothesis test specifications. Finally, it enters these results into another run of CATMOD, which performs automated direct input of the survey design specifications and accomplishes the appropriate analysis. This customized SAS program can be employed, with minor editing, to analyze general categorical, repeated measures marginal models on sample surveys with replicate weights. Finally, the results of our analysis accounting for the survey design are compared to the results of two alternate analyses of the same data. This comparison confirms that such alternate analyses, which do not properly account for the design, do not produce useful results.

  13. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  14. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  15. Prognostic usefulness of repeated echocardiographic evaluation after acute myocardial infarction. TRACE Study Group. TRAndolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Korup, E; Køber, L; Torp-Pedersen, C

    1999-01-01

    The prognostic value of repeated echocardiographic measurement of left ventricular function after acute myocardial infarction was evaluated. We found that repeated measurements of wall motion index in survivors of acute myocardial infarction, with no reinfarction, provide important prognostic...

  16. Repeated assessment of orthotopic glioma pO2 by multi-site EPR oximetry: A technique with the potential to guide therapeutic optimization by repeated measurements of oxygen

    Science.gov (United States)

    Khan, Nadeem; Mupparaju, Sriram; Hou, Huagang; Williams, Benjamin B.; Swartz, Harold

    2011-01-01

    Tumor hypoxia plays a vital role in therapeutic resistance. Consequently, measurements of tumor pO2 could be used to optimize the outcome of oxygen-dependent therapies, such as, chemoradiation. However, the potential optimizations are restricted by the lack of methods to repeatedly and quantitatively assess tumor pO2 during therapies, particularly in gliomas. We describe the procedures for repeated measurements of orthotopic glioma pO2 by multi-site electron paramagnetic resonance (EPR) oximetry. This oximetry approach provides simultaneous measurements of pO2 at more than one site in the glioma and contralateral cerebral tissue. The pO2 of intracerebral 9L, C6, F98 and U251 tumors, as well as contralateral brain, were measured repeatedly for five consecutive days. The 9L glioma was well oxygenated with pO2 of 27 - 36 mm Hg, while C6, F98 and U251 glioma were hypoxic with pO2 of 7 - 12 mm Hg. The potential of multi-site EPR oximetry to assess temporal changes in tissue pO2 was investigated in rats breathing 100% O2. A significant increase in F98 tumor and contralateral brain pO2 was observed on day 1 and day 2, however, glioma oxygenation declined on subsequent days. In conclusion, EPR oximetry provides the capability to repeatedly assess temporal changes in orthotopic glioma pO2. This information could be used to test and optimize the methods being developed to modulate tumor hypoxia. Furthermore, EPR oximetry could be potentially used to enhance the outcome of chemoradiation by scheduling treatments at times of increase in glioma pO2. PMID:22079559

  17. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  18. Counterbalancing and Other Uses of Repeated-Measures Latin-Square Designs: Analyses and Interpretations.

    Science.gov (United States)

    Reese, Hayne W.

    1997-01-01

    Recommends that when repeated-measures Latin-square designs are used to counterbalance treatments across a procedural variable or to reduce the number of treatment combinations given to each participant, effects be analyzed statistically, and that in all uses, researchers consider alternative interpretations of the variance associated with the…

  19. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  20. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  1. Acute caffeine effect on repeatedly measured P300

    OpenAIRE

    Pan, Jingbo; Takeshita, Tatsuya; Morimoto, Kanehisa

    2000-01-01

    The acute effect of a single-dose of caffeine on the P300 event-related brain potential (ERP) was assessed in a study using a repeatedly presented auditory oddball button-press task. A dose (5mg/kg body-weight) of either caffeine or placebo lactose, dissolved in a cup of decaffeinated coffee, was administered double-blindly to coffee drinkers who had abstained from coffee for 24hrs, with the presentation order of the sessions counterbalanced and separated by 2–4 weeks. The caffeine-treatment ...

  2. The Enigma of Rapid Repeat Pregnancy: A Qualitative Study of Teen Mothers.

    Science.gov (United States)

    Conroy, K N; Engelhart, T G; Martins, Y; Huntington, N L; Snyder, A F; Coletti, K D; Cox, J E

    2016-06-01

    Rapid repeat pregnancy accounts for 18% of teen pregnancies and leads to adverse health, economic, and developmental outcomes for teen mothers and their children. Few interventions have been successful in reducing rapid repeat pregnancy. In this qualitative study we examined adolescent mothers' perceptions of their decision-making and behaviors that helped prevent or promote a rapid repeat pregnancy. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: Semistructured interviews were conducted with 31 adolescent mothers, aged 16-21 years; 15 of these subjects experienced a repeat pregnancy within a year of their first child's birth and 16 had not. Two researchers used a grounded, inductive technique to identify emergent themes; interviews were subsequently coded accordingly. Counts were tabulated of the number of times themes were endorsed among those with or without a repeat pregnancy. Four overarching themes emerged from the interviews: intentionality regarding pregnancy planning, patients' degree of independence in making contraceptive choices, sense of control over life experience, and barriers to follow-through on contraceptive planning. Teens who had not experienced a rapid repeat pregnancy more often endorsed themes of intentionality in preventing or promoting a pregnancy, independence in decision-making, and feelings of control over their experience. Ambivalence and lack of decision-making about seeking another pregnancy were frequently endorsed by mothers who had experienced a second pregnancy. Decision-making regarding seeking or preventing a rapid repeat pregnancy is complex for teen mothers; techniques to help support decision-making or to delay pregnancy until decision-repeat making is complete might be important in reducing rapid pregnancy. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  3. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  4. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    International Nuclear Information System (INIS)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-01-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of [ 3 H]Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in [14C]iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress [an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures], although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results

  5. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  6. t2prhd: a tool to study the patterns of repeat evolution

    Directory of Open Access Journals (Sweden)

    Pénzes Zsolt

    2008-01-01

    Full Text Available Abstract Background The models developed to characterize the evolution of multigene families (such as the birth-and-death and the concerted models have also been applied on the level of sequence repeats inside a gene/protein. Phylogenetic reconstruction is the method of choice to study the evolution of gene families and also sequence repeats in the light of these models. The characterization of the gene family evolution in view of the evolutionary models is done by the evaluation of the clustering of the sequences with the originating loci in mind. As the locus represents positional information, it is straightforward that in the case of the repeats the exact position in the sequence should be used, as the simple numbering according to repeat order can be misleading. Results We have developed a novel rapid visual approach to study repeat evolution, that takes into account the exact repeat position in a sequence. The "pairwise repeat homology diagram" visualizes sequence repeats detected by a profile HMM in a pair of sequences and highlights their homology relations inferred by a phylogenetic tree. The method is implemented in a Perl script (t2prhd available for downloading at http://t2prhd.sourceforge.net and is also accessible as an online tool at http://t2prhd.brc.hu. The power of the method is demonstrated on the EGF-like and fibronectin-III-like (Fn-III domain repeats of three selected mammalian Tenascin sequences. Conclusion Although pairwise repeat homology diagrams do not carry all the information provided by the phylogenetic tree, they allow a rapid and intuitive assessment of repeat evolution. We believe, that t2prhd is a helpful tool with which to study the pattern of repeat evolution. This method can be particularly useful in cases of large datasets (such as large gene families, as the command line interface makes it possible to automate the generation of pairwise repeat homology diagrams with the aid of scripts.

  7. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction

    DEFF Research Database (Denmark)

    Paige, Ellie; Barrett, Jessica; Pennells, Lisa

    2017-01-01

    The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data...

  8. Tectonic, Climatic and Anthropogenic Vertical Land Movements in Western Europe by Repeated Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M. J.; de Viron, O.; Lecocq, T.; Hinzen, K. G.; Quinif, Y.; Williams, S. D.; Camelbeeck, T.

    2010-12-01

    In continental plate interiors, tectonic deformations are small and the associated ground surface movements remain close to or below the accuracy of current geodetic techniques, and at the limit of the noise level. An absolute gravimeter is an appropriate tool to quantify slow vertical movements, as this instrument, based on length and time standards, is drift free and does not depend on any terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformations in the area. After 7-13 years (depending on the station), we find evidence that the movements are no larger than a few millimeter per year and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. This demonstrates the importance of precisely modeling the GIA effects in order to investigate intraplate tectonic deformations at the sub-millimeter level. This study also shows that AG measurements, repeated once or twice a year, can resolve vertical velocities at the 1.0 mm/yr level after 10 years, even in difficult conditions, provided that the gravimeter is carefully maintained.

  9. Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

    OpenAIRE

    Ruiz-Belda, Clara; Piñero, David P.; Ruiz Fortes, Pedro; Soto-Negro, Roberto; Moya, Myriam; Pérez Cambrodí, Rafael J.; Artola, Alberto

    2016-01-01

    Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the C...

  10. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  11. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  12. Repeated absolute gravity measurements for monitoring slow intraplate vertical deformation in Western Europe

    Science.gov (United States)

    Van Camp, M. J.; de Viron, O.; Scherneck, H.; Hinzen, K. G.; Williams, S. D.; Lecocq, T.; Quinif, Y.; Camelbeeck, T.

    2011-12-01

    In continental plate interiors, ground surface movements are at the limit of the noise level and close to or below the accuracy of current geodetic techniques. Absolute gravity measurements are valuable to quantify slow vertical movements, as this instrument is drift free and, unlike GPS, independent of the terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformation in the area. The AG measurements, repeated once or twice a year, can resolve elusive gravity changes with a precision better than 3.7 nm/s2/yr (95% confidence interval) after 11 years, even in difficult conditions. After 8-15 years (depending on the station), we find that the gravity rates of change lie in the [-3.1, 8.1] nm/s2/yr interval and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. After correcting for the GIA, the inferred gravity rates and consequently, the vertical land movements, reduce to zero within the uncertainty level at all stations except Jülich (due to man-induced subsidence) and Sohier (possibly, an artefact due to the shortness of the time series at that station).

  13. [A case-control study of factors associated with repeat teen pregnancy based on a sample from a university maternity hospital].

    Science.gov (United States)

    Silva, Andréa de Albuquerque Arruda; Coutinho, Isabela C; Katz, Leila; Souza, Alex Sandro Rolland

    2013-03-01

    Repeat teen pregnancy is a frequent issue and is considered an aggravating factor for increased maternal and fetal morbidity and social problems. The aim of the study was to identify factors associated with repeat teen pregnancy. A case-control study was conducted in 90 postpartum adolescents with more than one pregnancy (cases) and 90 adult women with a history of only one pregnancy during adolescence (controls). Statistical analysis used hierarchical logistic regression with 5% significance. Early sexual initiation (pregnancy (pregnancy, while partner change was inversely associated. Repeat teen pregnancy was mainly associated with reproductive and socioeconomic factors. Partner change appeared as a protective factor. Measures should be adopted during the postpartum period of teenage mothers in order to avoid repeat pregnancy.

  14. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2018-01-01

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  15. Correcting for multivariate measurement error by regression calibration in meta-analyses of epidemiological studies

    DEFF Research Database (Denmark)

    Tybjærg-Hansen, Anne

    2009-01-01

    Within-person variability in measured values of multiple risk factors can bias their associations with disease. The multivariate regression calibration (RC) approach can correct for such measurement error and has been applied to studies in which true values or independent repeat measurements...... of the risk factors are observed on a subsample. We extend the multivariate RC techniques to a meta-analysis framework where multiple studies provide independent repeat measurements and information on disease outcome. We consider the cases where some or all studies have repeat measurements, and compare study......-specific, averaged and empirical Bayes estimates of RC parameters. Additionally, we allow for binary covariates (e.g. smoking status) and for uncertainty and time trends in the measurement error corrections. Our methods are illustrated using a subset of individual participant data from prospective long-term studies...

  16. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor) variables? This question was answered using generalized...... involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...

  17. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  18. Reproducibility and Reliability of Repeated Quantitative Fluorescence Angiography

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Knudsen, Kristine Bach Korsholm; Ambrus, Rikard

    2017-01-01

    INTRODUCTION: When using fluorescence angiography (FA) in perioperative perfusion assessment, repeated measures with re-injections of fluorescent dye (ICG) may be required. However, repeated injections may cause saturation of dye in the tissue, exceeding the limit of fluorescence intensity...... that the camera can detect. As the emission of fluorescence is dependent of the excitatory light intensity, reduction of this may solve the problem. The aim of the present study was to investigate the reproducibility and reliability of repeated quantitative FA during a reduction of excitatory light....

  19. Thermal stability of chicken brain {alpha}-spectrin repeat 17: a spectroscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Annette K. [University of Bergen, Department of Chemistry (Norway); Kieffer, Bruno [Ecole Superieure de Biotechnologie de Strasbourg, IGBMC Biomolecular NMR Group, CNRS UMR 7104 (France); Trave, Gilles [Ecole Superieure de Biotechnologie de Strasbourg, Equipe Oncoproteines, IREBS, UMR 7242 (France); Froystein, Nils Age [University of Bergen, Department of Chemistry (Norway); Raae, Arnt J., E-mail: arnt.raae@mbi.uib.no [University of Bergen, Department of Molecular Biology (Norway)

    2012-06-15

    Spectrin is a rod-like multi-modular protein that is mainly composed of triple-helical repeats. These repeats show very similar 3D-structures but variable conformational and thermodynamical stabilities, which may be of great importance for the flexibility and dynamic behaviour of spectrin in the cell. For instance, repeat 17 (R17) of the chicken brain spectrin {alpha}-chain is four times less stable than neighbouring repeat 16 (R16) in terms of Increment G. The structure of spectrin repeats has mainly been investigated by X-ray crystallography, but the structures of a few repeats, e.g. R16, have also been determined by NMR spectroscopy. Here, we undertook a detailed characterization of the neighbouring R17 by NMR spectroscopy. We assigned most backbone resonances and observed NOE restraints, relaxation values and coupling constants that all indicated that the fold of R17 is highly similar to that of R16, in agreement with previous X-ray analysis of a tandem repeat of the two domains. However, {sup 15}N heteronuclear NMR spectra measured at different temperatures revealed particular features of the R17 domain that might contribute to its lower stability. Conformational exchange appeared to alter the linker connecting R17 to R16 as well as the BC-loop in close proximity. In addition, heat-induced splitting was observed for backbone resonances of a few spatially related residues including V99 of helix C, which in R16 is replaced by the larger hydrophobic tryptophan residue that is relatively conserved among other spectrin repeats. These data support the view that the substitution of tryptophan by valine at this position may contribute to the lower stability of R17.

  20. Analyzing repeated measures data on individuals nested within groups: accounting for dynamic group effects.

    Science.gov (United States)

    Bauer, Daniel J; Gottfredson, Nisha C; Dean, Danielle; Zucker, Robert A

    2013-03-01

    Researchers commonly collect repeated measures on individuals nested within groups such as students within schools, patients within treatment groups, or siblings within families. Often, it is most appropriate to conceptualize such groups as dynamic entities, potentially undergoing stochastic structural and/or functional changes over time. For instance, as a student progresses through school, more senior students matriculate while more junior students enroll, administrators and teachers may turn over, and curricular changes may be introduced. What it means to be a student within that school may thus differ from 1 year to the next. This article demonstrates how to use multilevel linear models to recover time-varying group effects when analyzing repeated measures data on individuals nested within groups that evolve over time. Two examples are provided. The 1st example examines school effects on the science achievement trajectories of students, allowing for changes in school effects over time. The 2nd example concerns dynamic family effects on individual trajectories of externalizing behavior and depression. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  1. Direct and Repeated Clinical Measurements of pO2 for Enhancing Cancer Therapy and Other Applications.

    Science.gov (United States)

    Swartz, Harold M; Williams, Benjamin B; Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A; Chen, Eunice Y; Schaner, Philip E; Ali, Arif; Gallez, Bernard; Kuppusamy, Periannan; Flood, Ann B

    2016-01-01

    The first systematic multi-center study of the clinical use of EPR oximetry has begun, with funding as a PPG from the NCI. Using particulate oxygen sensitive EPR, materials in three complementary forms (India Ink, "OxyChips", and implantable resonators) the clinical value of the technique will be evaluated. The aims include using repeated measurement of tumor pO2 to monitor the effects of treatments on tumor pO2, to use the measurements to select suitable subjects for the type of treatment including the use of hyperoxic techniques, and to provide data that will enable existing clinical techniques which provide data relevant to tumor pO2 but which cannot directly measure it to be enhanced by determining circumstances where they can give dependable information about tumor pO2.

  2. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  3. Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

    Science.gov (United States)

    Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C

    2015-07-01

    The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p rc = 0.9981 vs. 0.9953; p plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.

  4. Validation and Reliability of a Smartphone Application for the International Prostate Symptom Score Questionnaire: A Randomized Repeated Measures Crossover Study

    Science.gov (United States)

    Shim, Sung Ryul; Sun, Hwa Yeon; Ko, Young Myoung; Chun, Dong-Il; Yang, Won Jae

    2014-01-01

    Background Smartphone-based assessment may be a useful diagnostic and monitoring tool for patients. There have been many attempts to create a smartphone diagnostic tool for clinical use in various medical fields but few have demonstrated scientific validity. Objective The purpose of this study was to develop a smartphone application of the International Prostate Symptom Score (IPSS) and to demonstrate its validity and reliability. Methods From June 2012 to May 2013, a total of 1581 male participants (≥40 years old), with or without lower urinary tract symptoms (LUTS), visited our urology clinic via the health improvement center at Soonchunhyang University Hospital (Republic of Korea) and were enrolled in this study. A randomized repeated measures crossover design was employed using a smartphone application of the IPSS and the conventional paper form of the IPSS. Paired t test under a hypothesis of non-inferior trial was conducted. For the reliability test, the intraclass correlation coefficient (ICC) was measured. Results The total score of the IPSS (P=.289) and each item of the IPSS (P=.157-1.000) showed no differences between the paper version and the smartphone version of the IPSS. The mild, moderate, and severe LUTS groups showed no differences between the two versions of the IPSS. A significant correlation was noted in the total group (ICC=.935, Psmartphones could participate. Conclusions The validity and reliability of the smartphone application version were comparable to the conventional paper version of the IPSS. The smartphone application of the IPSS could be an effective method for measuring lower urinary tract symptoms. PMID:24513507

  5. Psychological Processes and Repeat Suicidal Behavior: A Four-Year Prospective Study

    Science.gov (United States)

    2013-01-01

    Objective: Although suicidal behavior is a major public health concern, understanding of individually sensitive suicide risk mechanisms is limited. In this study, the authors investigated, for the first time, the utility of defeat and entrapment in predicting repeat suicidal behavior in a sample of suicide attempters. Method: Seventy patients hospitalized after a suicide attempt completed a range of clinical and psychological measures (depression, hopelessness, suicidal ideation, defeat, and entrapment) while in hospital. Four years later, a nationally linked database was used to determine who had been hospitalized again after a suicide attempt. Results: Over 4 years, 24.6% of linked participants were readmitted to hospital after a suicidal attempt. In univariate logistic regression analyses, defeat and entrapment as well as depression, hopelessness, past suicide attempts, and suicidal ideation all predicted suicidal behavior over this interval. However, in the multivariate analysis, entrapment and past frequency of suicide attempts were the only significant predictors of suicidal behavior. Conclusions: This longitudinal study supports the utility of a new theoretical model in the prediction of suicidal behavior. Individually sensitive suicide risk processes like entrapment could usefully be targeted in treatment interventions to reduce the risk of repeat suicidal behavior in those who have been previously hospitalized after a suicide attempt. PMID:23855989

  6. The Queensland study of Melanoma: Environmental and Genetic Associations (Q-MEGA). Study design, baseline characteristics, and repeatability of phenotype and sun exposure measures

    Science.gov (United States)

    Baxter, Amanda J.; Hughes, Maria Celia; Kvaskoff, Marina; Siskind, Victor; Shekar, Sri; Aitken, Joanne F.; Green, Adele C.; Duffy, David L.; Hayward, Nicholas K.; Martin, Nicholas G.; Whiteman, David C.

    2013-01-01

    Cutaneous malignant melanoma (CMM) is a major health issue in Queensland, Australia which has the world’s highest incidence. Recent molecular and epidemiologic studies suggest that CMM arises through multiple etiological pathways involving gene-environment interactions. Understanding the potential mechanisms leading to CMM requires larger studies than those previously conducted. This article describes the design and baseline characteristics of Q-MEGA, the Queensland study of Melanoma: Environmental and Genetic Associations, which followed-up four population-based samples of CMM patients in Queensland, including children, adolescents, men aged over 50, and a large sample of adult cases and their families, including twins. Q-MEGA aims to investigate the roles of genetic and environmental factors, and their interaction, in the etiology of melanoma. 3,471 participants took part in the follow-up study and were administered a computer-assisted telephone interview in 2002–2005. Updated data on environmental and phenotypic risk factors, and 2,777 blood samples were collected from interviewed participants as well as a subset of relatives. This study provides a large and well-described population-based sample of CMM cases with follow-up data. Characteristics of the cases and repeatability of sun exposure and phenotype measures between the baseline and the follow-up surveys, from six to 17 years later, are also described. PMID:18361720

  7. Recommendations for analysis of repeated-measures designs: testing and correcting for sphericity and use of manova and mixed model analysis.

    Science.gov (United States)

    Armstrong, Richard A

    2017-09-01

    A common experimental design in ophthalmic research is the repeated-measures design in which at least one variable is a within-subject factor. This design is vulnerable to lack of 'sphericity' which assumes that the variances of the differences among all possible pairs of within-subject means are equal. Traditionally, this design has been analysed using a repeated-measures analysis of variance (RM-anova) but increasingly more complex methods such as multivariate anova (manova) and mixed model analysis (MMA) are being used. This article surveys current practice in the analysis of designs incorporating different factors in research articles published in three optometric journals, namely Ophthalmic and Physiological Optics (OPO), Optometry and Vision Science (OVS), and Clinical and Experimental Optometry (CXO), and provides advice to authors regarding the analysis of repeated-measures designs. Of the total sample of articles, 66% used a repeated-measures design. Of those articles using a repeated-measures design, 59% and 8% analysed the data using RM-anova or manova respectively and 33% used MMA. The use of MMA relative to RM-anova has increased significantly since 2009/10. A further search using terms to select those papers testing and correcting for sphericity ('Mauchly's test', 'Greenhouse-Geisser', 'Huynh and Feld') identified 66 articles, 62% of which were published from 2012 to the present. If the design is balanced without missing data then manova should be used rather than RM-anova as it gives better protection against lack of sphericity. If the design is unbalanced or with missing data then MMA is the method of choice. However, MMA is a more complex analysis and can be difficult to set up and run, and care should be taken first, to define appropriate models to be tested and second, to ensure that sample sizes are adequate. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  8. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients...... with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...... macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm...

  9. Characterisation and measurement of signals generated by DVB-H 'gap-filler' repeaters

    International Nuclear Information System (INIS)

    Baldini, M.; Barellini, A.; Bogi, L.; Licitra, G.; Silvi, A. M.; Zari, A.

    2009-01-01

    DVB-H (Digital Video Broadcasting Hand-held) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains. (authors)

  10. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  11. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  12. Repeatable aversion across threat types is linked with life-history traits but is dependent on how aversion is measured.

    Science.gov (United States)

    Davidson, Gabrielle L; Reichert, Michael S; Crane, Jodie M S; O'Shea, William; Quinn, John L

    2018-02-01

    Personality research suggests that individual differences in risk aversion may be explained by links with life-history variation. However, few empirical studies examine whether repeatable differences in risk avoidance behaviour covary with life-history traits among individuals in natural populations, or how these links vary depending on the context and the way risk aversion is measured. We measured two different risk avoidance behaviours (latency to enter the nest and inspection time) in wild great tits ( Parus major ) in two different contexts-response to a novel object and to a predator cue placed at the nest-box during incubation---and related these behaviours to female reproductive success and condition. Females responded equally strongly to both stimuli, and although both behaviours were repeatable, they did not correlate. Latency to enter was negatively related to body condition and the number of offspring fledged. By contrast, inspection time was directly explained by whether incubating females had been flushed from the nest before the trial began. Thus, our inferences on the relationship between risk aversion and fitness depend on how risk aversion was measured. Our results highlight the limitations of drawing conclusions about the relevance of single measures of a personality trait such as risk aversion.

  13. Reduction and technical simplification of testing protocol for walking based on repeatability analyses: An Interreg IVa pilot study

    Directory of Open Access Journals (Sweden)

    Nejc Sarabon

    2010-12-01

    Full Text Available The aim of this study was to define the most appropriate gait measurement protocols to be used in our future studies in the Mobility in Ageing project. A group of young healthy volunteers took part in the study. Each subject carried out a 10-metre walking test at five different speeds (preferred, very slow, very fast, slow, and fast. Each walking speed was repeated three times, making a total of 15 trials which were carried out in a random order. Each trial was simultaneously analysed by three observers using three different technical approaches: a stop watch, photo cells and electronic kinematic dress. In analysing the repeatability of the trials, the results showed that of the five self-selected walking speeds, three of them (preferred, very fast, and very slow had a significantly higher repeatability of the average walking velocity, step length and cadence than the other two speeds. Additionally, the data showed that one of the three technical methods for gait assessment has better metric characteristics than the other two. In conclusion, based on repeatability, technical and organizational simplification, this study helped us to successfully define a simple and reliable walking test to be used in the main study of the project.

  14. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  15. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  16. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    with first year seed crops using three sowing rates and three spring nitrogen (N) application rates. PLSR models were developed for each year and showed correlation coefficients of 0.71, 0.76, and 0.92, respectively. Regression coefficients showed in these experiments that the optimum time for canopy...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development......Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...

  17. Discontinuous Patterns of Cigarette Smoking From Ages 18 to 50 in the United States: A Repeated-Measures Latent Class Analysis.

    Science.gov (United States)

    Terry-McElrath, Yvonne M; O'Malley, Patrick M; Johnston, Lloyd D

    2017-12-13

    Effective cigarette smoking prevention and intervention programming is enhanced by accurate understanding of developmental smoking pathways across the life span. This study investigated within-person patterns of cigarette smoking from ages 18 to 50 among a US national sample of high school graduates, focusing on identifying ages of particular importance for smoking involvement change. Using data from approximately 15,000 individuals participating in the longitudinal Monitoring the Future study, trichotomous measures of past 30-day smoking obtained at 11 time points were modeled using repeated-measures latent class analyses. Sex differences in latent class structure and membership were examined. Twelve latent classes were identified: three characterized by consistent smoking patterns across age (no smoking; smoking developing effective smoking prevention and intervention programming. This study examined cigarette smoking among a national longitudinal US sample of high school graduates from ages 18 to 50 and identified distinct latent classes characterized by patterns of movement between no cigarette use, light-to-moderate smoking, and the conventional definition of heavy smoking at 11 time points via repeated-measures latent class analysis. Membership probabilities for each smoking class were estimated, and critical ages of susceptibility to change in smoking behaviors were identified. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Performance Analysis of Measurement Inaccuracies of IMU/GPS on Airborne Repeat-pass Interferometric SAR in the Presence of Squint

    Directory of Open Access Journals (Sweden)

    Deng Yuan

    2014-08-01

    Full Text Available In the MOtion COmpensation (MOCO approach to airborne repeat-pass interferometric Synthetic Aperture Radar (SAR based on motion measurement data, the measurement inaccuracies of Inertial Measurement Unit/Global Positioning System (IMU/GPS and the positioning errors of the target, which may contribute to the residual uncompensated motion errors, affect the imaging result and interferometric measurement. Considering the effects of the two types of error, this paper builds a mathematical model of residual motion errors in presence of squint, and analyzes the effects on the residual motion errors induced by the measurement inaccuracies of IMU/GPS and the positioning errors of the target. In particular, the effects of various measurement inaccuracies of IMU/GPS on interferometric SAR image quality, interferometric phase, and digital elevation model precision are disscussed. Moreover, the paper quantitatively researches the effects of residual motion errors on airborne repeat-pass interferometric SAR through theoretical and simulated analyses and provides theoretical bases for system design and signal processing.

  19. PTSD and DNA Methylation in Select Immune Function Gene Promoter Regions: A Repeated Measures Case-control Study of U.S. Military Service Members

    Science.gov (United States)

    2013-06-24

    other relevant exposures which may influ- ence DNA methylation , such as dietary factors ( folate , vitamin B12 intake) (Fenech, 2001; Piyathilake and...ARTICLE published: 24 June 2013 doi: 10.3389/fpsyt.2013.00056 PTSD and DNA methylation in select immune function gene promoter regions: a repeated measures...largely unknown. Dis- tinct expression signatures for PTSD have been found, in particular for immune activation transcripts. DNA methylation may be

  20. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... to missing data, 730 children were included in the current analytical sample. An accelerometer was worn for 7 days and 8 nights during autumn, winter and spring, from which physical activity, sedentary time and sleep duration were measured. Cardio-respiratory fitness was assessed using a 10-min intermittent...

  1. How to measure kyphosis in everyday clinical practice: a reliability study on different methods.

    Science.gov (United States)

    Zaina, Fabio; Donzelli, Sabrina; Lusini, Monia; Negrini, Stefano

    2012-01-01

    The sagittal plane measures have a relevant role both in Idiopathic Scoliosis (AIS) and in Hyperkyphosis (HK) management. Nevertheless, clinical tools for everyday use are scarce and not adequately studied. To assess the repeatability of different methods for the collection of the sagittal profile of patients with spinal deformities during everyday clinics. We performed 4 different studies in 4 different populations of AIS and HK patients. In the first study we reported the normative data and measurement error of the plumbline measures in a general population of 180 adolescents. In the second study we compared the sagittal distances from the plumbline of C7, T12, L3, and Sagittal Index (SI = C7+L3) with the measures of the Video Rasterstereography at the same levels and the angles of kyphosis and lordosis in 100 AIS patients. In the third study we evaluated the intra and inter-rater repeatability and the measurement error of kyphosis and lordosis angles measured with the Inclimed in 100 AIS patients. In the last study we evaluated the repeatability of the sagittal distances from the plumbline, by using a 1 mm change instead of 5 mm in a population of 40 patients. repeatability has been evaluated according to Bland and Altman, to identify the limits of variation that are clinically significant. Results. Study 1: the normative data were: females: 34 ± 11 mm for C7; 34 ± 15 mm for L3, males: 34 ± 10 mm for C7; 48 ± 10 mm for L3;. Study 2: a coefficient of correlation was calculated in order to compare measures. Study 3: the k value for Inclimed varied from fair to good. Study 4: the repeatability was fair for this measure. Some clinical instruments are now available for sagittal plane assessment in AIS and hyperkyphosis. The results of the present study report the limits during measurements in a clinical setting of parameters that are routinely collected by some clinicians.

  2. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  3. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  4. Synthetic food coloring and behavior: a dose response effect in a double-blind, placebo-controlled, repeated-measures study.

    Science.gov (United States)

    Rowe, K S; Rowe, K J

    1994-11-01

    To establish whether there is an association between the ingestion of synthetic food colorings and behavioral change in children referred for assessment of "hyperactivity." From approximately 800 children referred to the Royal Children's Hospital (Melbourne) for assessment of suspected hyperactivity, 200 were included in a 6-week open trial of a diet free of synthetic food coloring. The parents of 150 children reported behavioral improvement with the diet, and deterioration on the introduction of foods noted to contain synthetic coloring. A 30-item behavioral rating inventory was devised from an examination of the clinical histories of 50 suspected reactors. Thirty-four other children (23 suspected reactors, 11 uncertain reactors) and 20 control subjects, aged 2 to 14 years, were studied. A 21-day, double-blind, placebo-controlled, repeated-measures study used each child as his or her own control. Placebo, or one of six dose levels of tartrazine (1, 2, 5, 10, 20, 50 mg), was administered randomly each morning, and behavioral ratings were recorded by parents at the end of each 24 hours. The study identified 24 children as clear reactors (19 of 23 "suspected reactors," 3 of 11 "uncertain reactors," and 2 of 20 "control subjects"). They were irritable and restless and had sleep disturbance. Significant reactions were observed at all six dose levels. A dose response effect was obtained. With a dose increase greater than 10 mg, the duration of effect was prolonged. Behavioral changes in irritability, restlessness, and sleep disturbance are associated with the ingestion of tartrazine in some children. A dose response effect was observed.

  5. Kinematic repeatability of a multi-segment foot model for dance.

    Science.gov (United States)

    Carter, Sarah L; Sato, Nahoko; Hopper, Luke S

    2018-03-01

    The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.

  6. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    Science.gov (United States)

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  7. SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, J; Humm, J; Nehmeh, S; Schoder, H [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be.

  8. SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

    International Nuclear Information System (INIS)

    Schwartz, J; Humm, J; Nehmeh, S; Schoder, H

    2015-01-01

    Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be

  9. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  10. Repeatability of an automated Landolt C test, compared with the early treatment of diabetic retinopathy study (ETDRS) chart testing.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Tiensuwan, Montip; Kunawut, Catleya; Masayaanon, Patcharapim

    2003-10-01

    To evaluate the repeatability of visual acuity scores from the automated test and compare them with the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. Instrument validation study based on a model of repeatability study in two observations. SMETHODS: a prospective, clinic-based, comparative study. A total of 206 participants without ocular diseases and refractive errors in their right eyes were randomly enrolled in the automated group in which 107 participants performed the automated test and the ETDRS group in which 99 participants read the ETDRS chart. All participants were tested with only their right eyes without corrections at 4 meters and came back to have the same tests 1 week later. The automated test used the Landolt rings as optotypes and was conducted by a low-ended personal computer with a 15-inch monitor and a wireless keyboard. The "letter" score calculated by counting every correct response to optotypes, and the "threshold curve" score interpreted from the optotype size at the midpoint of a visual acuity threshold curve. The 95% confidence interval of test-retest of visual acuity scores from the automated test are comparable to the ETDRS chart (.143 compared with.125 for letter scores,.145 compared with.122 for threshold curve scores). The score repeatabilities, calculated from the standard deviations of test-retest, from the automated test are also comparable to the ETDRS chart (.201 compared with.177 for letter scores,.206 compared with.172 for threshold curve scores). All comparisons demonstrated no statistical difference (P >.05). The automated testing system in this study enables practical measuring visual acuity by the Landolt rings. The system's repeatability, which is comparable to the ETDRS chart, supports its role as an alternative tool for measuring outcome in new clinical research. Its ability to practically generate visual acuity threshold curves may also be useful in future clinical research studies.

  11. Exposing Students to Repeat Photography: Increasing Cultural Understanding on a Short-Term Study Abroad

    Science.gov (United States)

    Lemmons, Kelly K.; Brannstrom, Christian; Hurd, Danielle

    2014-01-01

    Traditionally, repeat photography has been used to analyze land cover change. This paper describes how repeat photography may be used as a tool to enhance the short-term study abroad experience by facilitating cultural interaction and understanding. We present evidence from two cases and suggest a five-step repeat photography method for educators…

  12. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Phypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  13. Theoretical repeatability assessment without repetitive measurements in gradient high-performance liquid chromatography.

    Science.gov (United States)

    Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki

    2016-07-08

    This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Computational study of the human dystrophin repeats: interaction properties and molecular dynamics.

    Directory of Open Access Journals (Sweden)

    Baptiste Legrand

    Full Text Available Dystrophin is a large protein involved in the rare genetic disease Duchenne muscular dystrophy (DMD. It functions as a mechanical linker between the cytoskeleton and the sarcolemma, and is able to resist shear stresses during muscle activity. In all, 75% of the dystrophin molecule consists of a large central rod domain made up of 24 repeat units that share high structural homology with spectrin-like repeats. However, in the absence of any high-resolution structure of these repeats, the molecular basis of dystrophin central domain's functions has not yet been deciphered. In this context, we have performed a computational study of the whole dystrophin central rod domain based on the rational homology modeling of successive and overlapping tandem repeats and the analysis of their surface properties. Each tandem repeat has very specific surface properties that make it unique. However, the repeats share enough electrostatic-surface similarities to be grouped into four separate clusters. Molecular dynamics simulations of four representative tandem repeats reveal specific flexibility or bending properties depending on the repeat sequence. We thus suggest that the dystrophin central rod domain is constituted of seven biologically relevant sub-domains. Our results provide evidence for the role of the dystrophin central rod domain as a scaffold platform with a wide range of surface features and biophysical properties allowing it to interact with its various known partners such as proteins and membrane lipids. This new integrative view is strongly supported by the previous experimental works that investigated the isolated domains and the observed heterogeneity of the severity of dystrophin related pathologies, especially Becker muscular dystrophy.

  15. A study on the repeatability of ultrasonic testing data

    International Nuclear Information System (INIS)

    Yoshimura, Seiichi; Fukumoto, Hiroshi

    1980-01-01

    Reliability improvement of ultrasonic testing data is strongly desired in ultrasonic testing working of nuclear power plants. This paper deals with the problems of the testing by the manual and the remote control apparatus, and with the factors which influence the repeatability of ultrasonic testing data. Following results are found in it. (1) In the testing by the manual, working time and posture influence the repeatability of testing data. (2) Glycerin in suitable for the couplant in the respect of the repeatability of testing data. In the case of using machine oil, the pressure to the probe necessitates to be over 0.2 kg/cm 2 . (3) In the testing by the remote control apparatus, working time, working environment and defect position does not influence the repeatability of testing data. (author)

  16. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  17. Repeatability of measures of inflammatory cell number in bronchial biopsies in atopic asthma

    NARCIS (Netherlands)

    Sont, J. K.; Willems, L. N.; Evertse, C. E.; Hooijer, R.; Sterk, P. J.; van Krieken, J. H.

    1997-01-01

    Airway pathology is increasingly considered to be a major outcome in asthma research. The aim of this study was to examine the intra-observer, within-section and between-biopsy repeatability, together with the implications for statistical power of a computerized quantitative analysis of inflammatory

  18. Measurements of Repeated Tightening and Loosening Torque of Seven Different Implant/Abutment Connection Designs and Their Modifications: An In Vitro Study.

    Science.gov (United States)

    Butkevica, Alena; Nathanson, Dan; Pober, Richard; Strating, Herman

    2018-02-01

    Repeated tightening and loosening of the abutment screw may alter its mechanical and physical properties affecting the optimal torque and ultimate reliability of an implant/abutment connection. The purpose of this study was to evaluate the effect of repeated tightening and loosening of implant/abutment screws on the loosening torque of implant/abutment connections of commercially available implant systems. Seven different implant/abutment connections and their modifications were tested. The screws of each system were tightened according to the manufacturer's specifications. After 20 minutes the screws were loosened. This procedure was repeated ten times, and the differences between the 1st and 10th cycle were expressed as a percentage change RTq(%) and correlated with initial torque, the number of threads, the length of shank, and thread surface area employing Spearman's analysis. All systems showed significant differences in residual torque (RTq) value (p 0.05). All connections but group 3 (p = 1.000) showed a significant change from the initial torque (ITq) to the RTq values. The first successive RTq values increased in two connection groups 1 and 2. The remaining connections showed reduced RTq values ranging from -1.2 % (group 5) to -23.5% (group 6). The RTq values declined gradually with every repeated tightening in groups 1, 2, 3, 8, 9, 11, 12. In group 2, after the tenth tightening the RTq was still above the ITq value. Only length of shank demonstrated a correlation with the RTq(%) change over the successive tightening loosening cycles (p abutment screws caused varying torque level changes among the different systems. These observations can probably be attributed to connection design. Limiting the number of tightening/loosening cycles in clinical and laboratory procedures is advisable for most of the implant systems tested. © 2016 by the American College of Prosthodontists.

  19. Can father inclusive practice reduce paternal postnatal anxiety? A repeated measures cohort study using the hospital anxiety and depression scale

    Directory of Open Access Journals (Sweden)

    Tohotoa Jenny

    2012-07-01

    Full Text Available Abstract Background Perinatal research on anxiety and depression has primarily focused on mothers. We have limited knowledge of fathers’ anxiety during the perinatal period yet there is evidence that the parenting capacity of a person can be compromised by anxiety and depression. The purpose of this paper is to identify the impact of a father inclusive intervention on perinatal anxiety and depression. The prime focus of the intervention was to provide education and support to fathers of breastfeeding partners with the aim of increasing both initiation and duration of breastfeeding. Methods A repeated measures cohort study was conducted during a RCT that was implemented across eight public maternity hospitals in Perth, Western Australia between May 2008 and June 2009. A baseline questionnaire which included the Hospital Anxiety and Depression Scale (HADS was administered to all participants on the first night of their hospital based antenatal education program and was repeated at six weeks postnatal. SPSS version 17 was used for reporting descriptive results. Results The mean anxiety levels at baseline for the fathers in the intervention group (n=289 and control group (n=244 were 4.58 and 4.22 respectively. At 6 weeks postnatal (only matched pairs, intervention and control group were 3.93 and 3.79. More intervention group fathers self-rated less anxiety compared to the fathers in the control group from baseline to post test (p=0.048. Depression scores for intervention fathers at baseline (mean =1.09 and at six weeks (mean=1.09 were very similar to fathers in the control group at baseline (mean=1.11 and at six weeks (mean =1.07 with no significant changes. Conclusions Both intervention and control group fathers experienced some anxiety prior to the birth of their baby, but this was rapidly reduced at six weeks. Paternal anxiety is common to new fathers and providing them with information and strategies for problem-solving can increase their

  20. Comparing Young and Elderly Serial Reaction Time Task Performance on Repeated and Random Conditions

    Directory of Open Access Journals (Sweden)

    Fatemeh Ehsani

    2012-07-01

    Full Text Available Objectives: Acquisition motor skill training in elderly is at great importance. The main purpose of this study was to compare young and elderly performance in serial reaction time task on different repeated and random conditions. Methods & Materials: A serial reaction time task by using software was applied for studying motor learning in 30 young and 30 elderly. Each group divided randomly implicitly and explicitly into subgroups. A task 4 squares with different colors appeared on the monitor and subjects were asked to press its defined key immediately after observing it. Subjects practiced 8 motor blocks (4 repeated blocks, then 2 random blocks and 2 repeated blocks. Block time that was dependent variable measured and Independent-samples t- test with repeated ANOVA measures were used in this test. Results: young groups performed both repeated and random sequences significantly faster than elderly (P0.05. Explicit older subgroup performed 7,8 blocks slower than 6 block with a significant difference (P<0.05. Conclusion: Young adults discriminate high level performance than elderly in both repeated and random practice. Elderly performed random practice better than repeated practice.

  1. Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds.

    Science.gov (United States)

    Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip

    2018-03-22

    To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.

  2. The effects of toluene plus noise on hearing thresholds: an evaluation based on repeated measurements in the German printing industry.

    Science.gov (United States)

    Schäper, Michael; Seeber, Andreas; van Thriel, Christoph

    2008-01-01

    The ototoxicity of occupational exposure to toluene plus noise was investigated in a longitudinal study in rotogravure printing and existing findings in the literature were evaluated. The study comprised four repeated examinations during 5 years and started with 333 male workers. Lifetime weighted average exposures (LWAE) to toluene and noise were determined from individual work histories and historic recordings; recent individual exposures were measured 10 times during the study (toluene, active sampling; noise, stationary measurements). Auditory thresholds were measured with pure tone audiometry at 0.125, 0.25, 0.5, 0.75, 1, 2, 3, 4, 6, 8, 12 kHz. Mean LWAE exposures to toluene and noise were 45+/-17 ppm plus 82+/-7 dB(A) for high toluene exposed and 10+/-7 ppm plus 82+/-4 dB(A) for low toluene exposed subjects, mean current exposures were 26+/-20 ppm plus 81+/-4 dB(A) and 3+/-3 ppm plus 82+/-4 dB(A). Mean exposure duration was 21.3+/-6.5 years for long exposed and 5.9+/-2.2 years for short exposed subjects. Repeated measurement analyses of variance did not reveal effects of toluene intensity, exposure duration and interactions between toluene intensity and noise intensity. Noise intensity [79+/-3 dB(A) vs. 84+/-1 dB(A)] was significant for auditory thresholds. A case concept utilising developments of individual auditory thresholds did not reveal significant toluene effects. Logistic models including age, exposure duration, toluene in ambient air, current noise and either hippuric acid or ortho-cresol (o-cresol) found only age to be significant for elevated OR of high frequency hearing loss. Due to missing toluene effects, it was concluded that the threshold level for developing hearing loss as a result of occupational exposure to toluene plus noise might be above the current limit of 50 ppm toluene.

  3. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between......, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity....

  4. Baseline repeated measures from controlled human exposure studies: associations between ambient air pollution exposure and the systemic inflammatory biomarkers IL-6 and fibrinogen.

    Science.gov (United States)

    Thompson, Aaron M S; Zanobetti, Antonella; Silverman, Frances; Schwartz, Joel; Coull, Brent; Urch, Bruce; Speck, Mary; Brook, Jeffrey R; Manno, Michael; Gold, Diane R

    2010-01-01

    Systemic inflammation may be one of the mechanisms mediating the association between ambient air pollution and cardiovascular morbidity and mortality. Interleukin-6 (IL-6) and fibrinogen are biomarkers of systemic inflammation that are independent risk factors for cardio-vascular disease. We investigated the association between ambient air pollution and systemic inflammation using baseline measurements of IL-6 and fibrinogen from controlled human exposure studies. In this retrospective analysis we used repeated-measures data in 45 nonsmoking subjects. Hourly and daily moving averages were calculated for ozone, nitrogen dioxide, sulfur dioxide, and particulate matter pollutants on systemic IL-6 and fibrinogen. Effect modification by season was considered. We observed a positive association between IL-6 and O3 [0.31 SD per O3 interquartile range (IQR); 95% confidence interval (CI), 0.080.54] and between IL-6 and SO2 (0.25 SD per SO2 IQR; 95% CI, 0.060.43). We observed the strongest effects using 4-day moving averages. Responses to pollutants varied by season and tended to be higher in the summer, particularly for O3 and PM2.5. Fibrinogen was not associated with pollution. This study demonstrates a significant association between ambient pollutant levels and baseline levels of systemic IL-6. These findings have potential implications for controlled human exposure studies. Future research should consider whether ambient pollution exposure before chamber exposure modifies IL-6 response.

  5. Repeatability of the Oxford Foot Model in children with foot deformity.

    Science.gov (United States)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Testing Mean Differences among Groups: Multivariate and Repeated Measures Analysis with Minimal Assumptions.

    Science.gov (United States)

    Bathke, Arne C; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne

    2018-03-22

    To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer's disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved.

  7. Aging, recall and recognition: a study on the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT).

    Science.gov (United States)

    Parker, Elizabeth S; Landau, Susan M; Whipple, Stephen C; Schwartz, Barbara L

    2004-05-01

    This study examines the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT) to the effects of aging in a sample of 112 men and women from 18 to 93 years old. Two new recognition measures, yes-no and forced-choice, were developed to supplement the original USC-REMT which measured only free-recall. Free-recall, yes-no recognition and forced-choice recognition were sensitive to age effects, with free-recall being the most sensitive. The seven recall and recognition lists can be used interchangeably. The data indicate that the USC-REMT is worthy of consideration when there is a need for a brief, screening tool of various memory functions, particularly when there is interest in memory changes over time and repeated assessments.

  8. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  9. Study of four week repeated dose toxic test of Sweet Bee Venom in Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Jae-Seuk Park

    2010-12-01

    Full Text Available Objectives: This study was performed to analyse four week repeated dose toxicity of Sweet Bee Venom(Sweet BV extracted from the bee venom in Beagle dogs. Methods: All experiments were conducted under the regulations of Good Laboratory Practice (GLP at Biotoxtech Company, a non-clinical study authorized institution. Male and female Beagle dogs of 5-6 months old were chosen for the pilot study of four week repeated dose toxicity of Sweet BV which was administered at the level of 0.56㎎/㎏ body weight which is eighty times higher than the clinical application dosage as the high dosage, followed by 0.28 and 0.14㎎/㎏ as midium and low dosage, respectively. Equal amount of excipient(normal saline to the Sweet BV experiment groups was administered as the control group every day for four weeks. Results: 1. No mortality was witnessed in all of the experiment groups. 2. All experiment groups were appealed pain sense in the treating time compared to the control group, and hyperemia and movement disorder were observed around the area of administration in all experiment groups, and higher occurrence in the higher dosage treatment. 3. For weight measurement, Neither male nor female groups showed significant changes. 4. In the urine analysis, CBC and biochemistry didn't show any significant changes in the experiment groups compared with control group. 5. For weight measurement of organs, experiment groups didn't show any significant changes compared with control group. 6. To verify abnormalities of organs and tissues, thigh muscle which treated with Sweet BV, cerebrum, liver, lung, kidney, and spinal cords were removed and conducted histologocal observation with H-E staining. In the histologocal observation of thigh muscle, cell infiltration, inflammatory, degeneration, necrosis of muscle fiber, and fibrosis were found in both thigh tissue. And the changes were depend on the dose of Sweet BV. But another organs were not detected in any abnormalities. 7

  10. A flow-cytometric NK-cytotoxicity assay adapted for use in rat repeated dose toxicity studies

    International Nuclear Information System (INIS)

    Marcusson-Staahl, Maritha; Cederbrant, Karin

    2003-01-01

    A recent regulatory document for immunotoxicity testing of new pharmaceutical drugs includes cytotoxic natural killer (NK)-cell function as a required parameter in repeated dose toxicity studies. The classical 51 Cr-release assay is the conventional test for cytotoxicity testing but several drawbacks with this assay has increased the demand for new reliable test systems. Here, we describe the optimisation of a flow-cytometric cytotoxicity assay especially adapted for regulatory rat studies in drug development. The test principle is based on target cell labelling with 5-(6)-carboxy-fluorescein succinimidyl ester (CFSE) and subsequent DNA-labelling with propidium iodide (PI) for identification of target cells with compromised cell membranes. The results are expressed as percentage of dead targets on a cell-to-cell basis. The final format of the assay includes 0.5 ml peripheral blood, 1.25x10 5 effector cells per sample, and collection of 500 target events by flow-cytometry. When NKR-P1+ cells were removed from the effector cell population by magnetic depletion the relative proportion decreased from 6 to 0.08%. The corresponding cytotoxic activity decreased from 68 to 8%. Also, the cytotoxic activity showed a significant and positive correlation with the proportion of NK-cells present in the effector cell suspension. Thus, the cytotoxicity measured is almost exclusively exerted by NK-cells. The current flow-cytometric test benefits from using peripheral blood as a source for effector cells since it will not conflict with the use of spleen for histopathological investigations in repeated dose toxicity studies. Additionally, since only a minimal number of effector cells are required per sample repeated testing of the same animal is enabled

  11. Repeated nicotine exposure enhances reward-related learning in the rat.

    Science.gov (United States)

    Olausson, Peter; Jentsch, J David; Taylor, Jane R

    2003-07-01

    Repeated exposure to addictive drugs causes neuroadaptive changes in cortico-limbic-striatal circuits that may underlie alterations in incentive-motivational processes and reward-related learning. Such drug-induced alterations may be relevant to drug addiction because enhanced incentive motivation and increased control over behavior by drug-associated stimuli may contribute to aspects of compulsive drug-seeking and drug-taking behaviors. This study investigated the consequences of repeated nicotine treatment on the acquisition and performance of Pavlovian discriminative approach behavior, a measure of reward-related learning, in male rats. Water-restricted rats were trained to associate a compound conditioned stimulus (tone+light) with the availability of water (the unconditioned stimulus) in 15 consecutive daily sessions. In separate experiments, rats were repeatedly treated with nicotine (0.35 mg/kg, s.c.) either (1) prior to the onset of training, (2) after each daily training session was completed (ie postsession injections), or (3) received nicotine both before the onset of training as well as after each daily training session. In this study, all nicotine treatment schedules increased Pavlovian discriminative approach behavior and, thus, prior repeated exposure to nicotine, repeated postsession nicotine injections, or both, facilitated reward-related learning.

  12. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  13. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  14. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  15. Film repeats in radiology department

    International Nuclear Information System (INIS)

    Suwan, A. Z.; Al-Shakharah, A. I

    1997-01-01

    During a one year period, 4910 radiographs of 55780 films were repeated. The objective of our study was to analyse and to classify the causes in order to minimize the repeats, cut the expenses and to provide optimal radiographs for accurate diagnosis. Analysis of the different factors revealed that, 43.6% of film repeats in our service were due to faults in exposure factors, centering comprises 15.9% of the repeats, while too much collimation was responsible for 7.6% of these repeats. All of which can be decreased by awareness and programmed training of technicians. Film blurring caused by patient motion was also responsible for 4.9% for radiographs reexamination, which can be minimized by detailed explanation to the patient and providing the necessary privacy. Fogging of X-Ray films by improper storage or inadequate handling or processing faults were responsible for 14.5% in repeats in our study. Methods and criteria for proper storage and handling of films were discussed. Recommendation for using modern day-light and laser processor has been high lighted. Artefacts are noticeably high in our cases, due to spinal dresses and frequent usage of precious metals for c osmotic purposes in this part of the world. The repeated films comprise 8.8% of all films We conclude that, the main factor responsible for repeats of up to 81.6% of cases was the technologists, thus emphasizing the importance of adequate training of the technologists. (authors). 15 refs., 9 figs., 1 table

  16. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    Science.gov (United States)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    temporally resolved measurements of the stable isotopes in xylem water, using a setup that can be easily repeated by other research groups. The method is anticipated to find broad application in ecohydrological analyses, and in tracer studies aimed at quantifying age distributions of soil water extracted by plant roots.

  17. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    Science.gov (United States)

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies

  18. Discrepancies in autobiographical memories— implications for the assessment of asylum seekers: repeated interviews study

    Science.gov (United States)

    Herlihy, Jane; Scragg, Peter; Turner, Stuart

    2002-01-01

    Objective To investigate the consistency of autobiographical memory of people seeking asylum, in light of the assumption that discrepancies in asylum seekers' accounts of persecution mean that they are fabricating their stories. Design Repeated interviews. Setting England, 1999 and 2000. Participants Community sample of 27 Kosovan and 12 Bosnian refugees. Main outcome measures Discrepancies in repeated descriptions of one traumatic and one non-traumatic event, including specific details, rated as central or peripheral to the event. Self report measures of post-traumatic stress disorder and depression. Results Discrepancies between an individual's accounts were common. For participants with high levels of post-traumatic stress, the number of discrepancies increased with length of time between interviews. More discrepancies occurred in details peripheral to the account than in details that were central to the account. Conclusion The assumption that inconsistency of recall means that accounts have poor credibility is questionable. Discrepancies are likely to occur in repeated interviews. For refugees showing symptoms of high levels of post-traumatic stress, the length of the application process may also affect the number of discrepancies. Recall of details rated by the interviewee as peripheral to the account is more likely to be inconsistent than recall of details that are central to the account. Thus, such inconsistencies should not be relied on as indicating a lack of credibility. What is already known on this topicDiscrepancies between accounts of an event are often used to judge the credibility of asylum seekersWhat this study addsDiscrepancies arise between two accounts of the same event even when there is no reason for fabricationRefugees with high levels of post-traumatic stress are more likely to give inconsistent accounts if they have a long time to wait between interviewsInterviewees are more likely to be inconsistent in details that they rate as peripheral

  19. Quantum repeated games revisited

    International Nuclear Information System (INIS)

    Frąckiewicz, Piotr

    2012-01-01

    We present a scheme for playing quantum repeated 2 × 2 games based on Marinatto and Weber’s approach to quantum games. As a potential application, we study the twice repeated Prisoner’s Dilemma game. We show that results not available in the classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games proposed by Iqbal and Toor. We point out the drawbacks that make their results unacceptable. (paper)

  20. Repeat Chlamydia trachomatis testing among heterosexual STI outpatient clinic visitors in the Netherlands: a longitudinal study.

    Science.gov (United States)

    Visser, Maartje; van Aar, Fleur; Koedijk, Femke D H; Kampman, Carolina J G; Heijne, Janneke C M

    2017-12-20

    Chlamydia infections are common in both men and women, are often asymptomatic and can cause serious complications. Repeat testing in high-risk groups is therefore indicated. In the Netherlands, guidelines on repeat chlamydia testing differ between testing facilities, and knowledge on repeat testing behaviour is limited. Here, we analyse the current repeat testing behaviour of heterosexual STI clinic visitors, and aim to identify groups for which repeat testing advice could be advantageous. Longitudinal surveillance data from all Dutch STI outpatient clinics were used, which included all STI clinic consultations carried out among heterosexual men and women between June 2014 and December 2015. Repeat testing was defined as returning to the same STI clinic between 35 days and 12 months after initial consultation. We calculated chlamydia positivity at repeat test stratified by initial test result and time between consultations. Logistic regression analyses were used to identify predictors of repeat testing, and predictors of having a chlamydia positive repeat test. In total, 140,486 consultations in 75,487 women and 46,286 men were available for analyses. Overall, 15.4% of women and 11.1% of men returned to the STI clinic within the study period. Highest chlamydia positivity at repeat test was seen 3-5 months after initial positive test. Among both women and men, repeat testing was associated with non-Western ethnicity, having had more than two sex partners in the past 6 months, reporting STI symptoms, having a history of STI, and having a chlamydia positive initial test. Among repeat testers, chlamydia positive repeat test was most strongly associated with younger age, followed by a chlamydia positive initial test. Repeat testing most often resulted in a positive test result among young heterosexuals (<25) and heterosexuals of any age with a chlamydia infection at the initial consultation. Further efforts are needed to determine optimal repeat testing strategies.

  1. The relationship of social support concept and repeat mammography among Iranian women.

    Science.gov (United States)

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  2. Study of four weeks repeated-dose toxic test of Sweet Bee Venom in rats Original Articles

    Directory of Open Access Journals (Sweden)

    Kwon Hae-Yon

    2011-03-01

    Full Text Available Objectives: This study was performed to analyse four weeks repeated -dose toxicity of Sweet Bee Venom (SBV-pure melittin, the major component of honey bee venom in rats. Methods: All experiments were conducted under the regulations of Good Laboratory Practice (GLPat Biotoxtech Company, a non-clinical study authorized institution. Male and female rats of 5 weeks old were chosen for the pilot study of four weeks repeated-dose toxicity and was injected at the level of 0.56 mg/kg body weight (eighty times higher than the clinical application dosage as the high dosage, followed by 0.28 and 0.14 mg/kg as midium and low dosage, respectively. Equal amount of normal saline was injected as the control group every day for four weeks. Results: 1. No mortality was witnessed in all of the experiment groups. 2. All experiment groups appealed pain sense in the treating time compared to the control group, and side effects such as hyperemia and movement disorder were observed around the area of injection in all experiment groups, and the higher dosage in treatment, the higher occurrence in side effects. 3. Concerning weight measurement, neither male nor female groups showed significant changes compared to the control group. 4. Concerning to the CBC and biochemistry, all experiment groups didn't show any significant changes compared to the control group. 5. Concerning weight measurement of organs, experiment groups didn't show any significant changes compared to the control group. 6. To verify abnormalities of organs and tissues, those such as cerebellum, cerebrum, liver, lung, kidney,and spinal cords were removed and we conducted histologocal observation with H-E staining.Concerning the histologocal observation of liver tissues, some fatty changes were observed around portal vein in 0.56 mg/kg experiment group. But another organs were not detected in any abnormalities. 7. The proper high dosage of SBV for the thirteen weeks repeated test in rats may be 0.28 mg

  3. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    Directory of Open Access Journals (Sweden)

    Rohit Shetty

    2017-01-01

    Full Text Available Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL haze on the measurement and repeatability of pachymetry and mean keratometry (Km of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL underwent imaging with a scanning slit imaging device (Orbscan II and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei. Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05 significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively. Km values were affected by haze when measured with the Pentacam HR (P < 0.05. The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively, Km values (P = 0.4 and 0.6, respectively, repeatability of TCT (P = 0.1 in both zones, and Km (P = 0.5 and 0.1, respectively with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution.

  4. Repeated measurements of NT-pro-B-type natriuretic peptide, troponin T or C-reactive protein do not predict future allograft rejection in heart transplant recipients.

    Science.gov (United States)

    Battes, Linda C; Caliskan, Kadir; Rizopoulos, Dimitris; Constantinescu, Alina A; Robertus, Jan L; Akkerhuis, Martijn; Manintveld, Olivier C; Boersma, Eric; Kardys, Isabella

    2015-03-01

    Studies on the prognostic value of serial biomarker assays for future occurrence of allograft rejection (AR) are scarce. We examined whether repeated measurements of NT-pro-B-type natriuretic peptide (NT-proBNP), troponin T (TropT) and C-reactive protein (CRP) predict AR. From 2005 to 2010, 77 consecutive heart transplantation (HTx) recipients were included. The NT-proBNP, TropT, and CRP were measured at 16 ± 4 (mean ± standard deviation) consecutive routine endomyocardial biopsy surveillance visits during the first year of follow-up. Allograft rejection was defined as International Society for Heart and Lung Transplantation (ISHLT) grade 2R or higher at endomyocardial biopsy. Joint modeling was used to assess the association between repeated biomarker measurements and occurrence of future AR. Joint modeling accounts for dependence among repeated observations in individual patients. The mean age of the patients at HTx was 49 ± 9.2 years, and 68% were men. During the first year of follow-up, 1,136 biopsies and concurrent blood samples were obtained, and 56 patients (73%) experienced at least one episode of AR. All biomarkers were elevated directly after HTx and achieved steady-state after ∼ 12 weeks, both in patients with or without AR. No associations were present between the repeated measurements of NT-proBNP, TropT, or CRP and AR both early (weeks 0-12) and late (weeks 13-52) in the course after HTx (hazard ratios for weeks 13-52: 0.96 (95% confidence interval, 0.55-1.68), 0.67 (0.27-1.69), and 1.44 (0.90-2.30), respectively, per ln[unit]). Combining the three biomarkers in one model also rendered null results. The temporal evolution of NT-proBNP, TropT, and CRP before AR did not predict occurrence of acute AR both in the early and late course of the first year after HTx.

  5. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  6. (In)Consistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Science.gov (United States)

    Froio de Araujo Dias, Gabriela; da Eira Silva, Vinicius; de Salles Painelli, Vitor; Sale, Craig; Giannini Artioli, Guilherme; Gualano, Bruno; Saunders, Bryan

    2015-01-01

    Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB). 15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m) completed six cycling capacity tests at 110% of maximum power output (CCT110%) following ingestion of either 0.3 g∙kg-1BM of SB (4 trials) or placebo (PL, 2 trials). Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD) was recorded as the exercise outcome. SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001); absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05). Blood lactate was elevated following exercise in all trials (p ≤ 0.001), and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05), although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none. The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation. ClinicalTrials.gov NCT02474628.

  7. (InConsistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Directory of Open Access Journals (Sweden)

    Gabriela Froio de Araujo Dias

    Full Text Available Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB.15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m completed six cycling capacity tests at 110% of maximum power output (CCT110% following ingestion of either 0.3 g∙kg-1BM of SB (4 trials or placebo (PL, 2 trials. Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD was recorded as the exercise outcome.SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001; absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05. Blood lactate was elevated following exercise in all trials (p ≤ 0.001, and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05, although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none.The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation.ClinicalTrials.gov NCT02474628.

  8. A Modified Jonckheere Test Statistic for Ordered Alternatives in Repeated Measures Design

    Directory of Open Access Journals (Sweden)

    Hatice Tül Kübra AKDUR

    2016-09-01

    Full Text Available In this article, a new test based on Jonckheere test [1] for  randomized blocks which have dependent observations within block is presented. A weighted sum for each block statistic rather than the unweighted sum proposed by Jonckheereis included. For Jonckheere type statistics, the main assumption is independency of observations within block. In the case of repeated measures design, the assumption of independence is violated. The weighted Jonckheere type statistic for the situation of dependence for different variance-covariance structure and the situation based on ordered alternative hypothesis structure of each block on the design is used. Also, the proposed statistic is compared to the existing test based on Jonckheere in terms of type I error rates by performing Monte Carlo simulation. For the strong correlations, circular bootstrap version of the proposed Jonckheere test provides lower rates of type I error.

  9. Interactional justice at work is related to sickness absence: a study using repeated measures in the Swedish working population.

    Science.gov (United States)

    Leineweber, Constanze; Bernhard-Oettel, Claudia; Peristera, Paraskevi; Eib, Constanze; Nyberg, Anna; Westerlund, Hugo

    2017-12-08

    Research has shown that perceived unfairness contributes to higher rates of sickness absence. While shorter, but more frequent periods of sickness absence might be a possibility for the individual to get relief from high strain, long-term sickness absence might be a sign of more serious health problems. The Uncertainty Management Model suggests that justice is particularly important in times of uncertainty, e.g. perceived job insecurity. The present study investigated the association between interpersonal and informational justice at work with long and frequent sickness absence respectively, under conditions of job insecurity. Data were derived from the 2010, 2012, and 2014 biennial waves of the Swedish Longitudinal Occupational Survey of Health (SLOSH). The final analytic sample consisted of 19,493 individuals. We applied repeated measures regression analyses through generalized estimating equations (GEE), a method for longitudinal data that simultaneously analyses variables at different time points. We calculated risk of long and frequent sickness absence, respectively in relation to interpersonal and informational justice taking perceptions of job insecurity into account. We found informational and interpersonal justice to be associated with risk of long and frequent sickness absence independently of job insecurity and demographic variables. Results from autoregressive GEE provided some support for a causal relationship between justice perceptions and sickness absence. Contrary to expectations, we found no interaction between justice and job insecurity. Our results underline the need for fair and just treatment of employees irrespective of perceived job insecurity in order to keep the workforce healthy and to minimize lost work days due to sickness absence.

  10. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  11. Ambient temperature and cardiovascular biomarkers in a repeated-measure study in healthy adults: A novel biomarker index approach.

    Science.gov (United States)

    Wu, Shaowei; Yang, Di; Pan, Lu; Shan, Jiao; Li, Hongyu; Wei, Hongying; Wang, Bin; Huang, Jing; Baccarelli, Andrea A; Shima, Masayuki; Deng, Furong; Guo, Xinbiao

    2017-07-01

    Associations of ambient temperature with cardiovascular morbidity and mortality have been well documented in numerous epidemiological studies, but the underlying pathways remain unclear. We investigated whether systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function may be the mechanistic pathways associated with ambient temperature. Forty study participants underwent repeated blood collections for 12 times in Beijing, China in 2010-2011. Ambient temperature and air pollution data were measured in central monitors close to student residences. We created five indices as the sum of weighted biomarker percentiles to represent the overall levels of 15 cardiovascular biomarkers in five pathways (systemic inflammation: hs-CRP, TNF-α and fibrinogen; coagulation: fibrinogen, PAI-1, tPA, vWF and sP-selectin; systemic oxidative stress: Ox-LDL and sCD36: antioxidant activity: EC-SOD and GPX1; and endothelial function: ET-1, E-selectin, ICAM-1 and VCAM-1). We used generalized mixed-effects models to estimate temperature effects controlling for air pollution and other covariates. There were significant decreasing trends in the adjusted means of biomarker indices over the lowest to the highest quartiles of daily temperatures before blood collection. A 10°C decrease at 2-d average daily temperature were associated with increases of 2.5% [95% confidence interval (CI): 0.7, 4.2], 1.6% (95% CI: 0.1, 3.1), 2.7% (95% CI: 0.5, 4.8), 5.5% (95% CI: 3.8, 7.3) and 2.0% (95% CI: 0.3, 3.8) in the indices for systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function, respectively. In contrast, the associations between ambient temperature and individual biomarkers had substantial variation in magnitude and strength. The altered cardiovascular biomarker profiles in healthy adults associated with ambient temperature changes may help explain the temperature-related cardiovascular morbidity

  12. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  13. Gender, obesity and repeated elevation of C-reactive protein: data from the CARDIA cohort.

    Directory of Open Access Journals (Sweden)

    Shinya Ishii

    Full Text Available C-reactive Protein (CRP measurements above 10 mg/L have been conventionally treated as acute inflammation and excluded from epidemiologic studies of chronic inflammation. However, recent evidence suggest that such CRP elevations can be seen even with chronic inflammation. The authors assessed 3,300 participants in The Coronary Artery Risk Development in Young Adults study, who had two or more CRP measurements between 1992/3 and 2005/6 to a investigate characteristics associated with repeated CRP elevation above 10 mg/L; b identify subgroups at high risk of repeated elevation; and c investigate the effect of different CRP thresholds on the probability of an elevation being one-time rather than repeated. 225 participants (6.8% had one-time and 103 (3.1% had repeated CRP elevation above 10 mg/L. Repeated elevation was associated with obesity, female gender, low income, and sex hormone use. The probability of an elevation above 10 mg/L being one-time rather than repeated was lowest (51% in women with body mass index above 31 kg/m(2, compared to 82% in others. These findings suggest that CRP elevations above 10 mg/L in obese women are likely to be from chronic rather than acute inflammation, and that CRP thresholds above 10 mg/L may be warranted to distinguish acute from chronic inflammation in obese women.

  14. A Systematic Review of Longitudinal Studies Which Measure Alzheimer's Disease Biomarkers.

    Science.gov (United States)

    Lawrence, Emma; Vegvari, Carolin; Ower, Alison; Hadjichrysanthou, Christoforos; De Wolf, Frank; Anderson, Roy M

    2017-01-01

    Alzheimer's disease (AD) is a progressive and fatal neurodegenerative disease, with no effective treatment or cure. A gold standard therapy would be treatment to slow or halt disease progression; however, knowledge of causation in the early stages of AD is very limited. In order to determine effective endpoints for possible therapies, a number of quantitative surrogate markers of disease progression have been suggested, including biochemical and imaging biomarkers. The dynamics of these various surrogate markers over time, particularly in relation to disease development, are, however, not well characterized. We reviewed the literature for studies that measured cerebrospinal fluid or plasma amyloid-β and tau, or took magnetic resonance image or fluorodeoxyglucose/Pittsburgh compound B-positron electron tomography scans, in longitudinal cohort studies. We summarized the properties of the major cohort studies in various countries, commonly used diagnosis methods and study designs. We have concluded that additional studies with repeat measures over time in a representative population cohort are needed to address the gap in knowledge of AD progression. Based on our analysis, we suggest directions in which research could move in order to advance our understanding of this complex disease, including repeat biomarker measurements, standardization and increased sample sizes.

  15. Studies on serum macro and micro minerals status in repeat breeder ...

    African Journals Online (AJOL)

    user01

    2014-03-05

    Mar 5, 2014 ... as well as 11.5% to gross domestic product. Repeat breeding is one of ... signs with no clinical detectable reproductive disorders. *Corresponding ... repeat breeding includes abnormal recommencement of postpartum ovarian ...

  16. EFFICIENCY OF REPEATED AND UNSCHEDULED TRAINING AS THE MEASURES TO PREVENT ACCIDENTS AT SUPPLY DEPOTS AND WAREHOUSES

    Directory of Open Access Journals (Sweden)

    Bocharova Irina Nikolaevna

    2013-05-01

    Full Text Available This paper presents the results of the analysis of the state of occupational safety at supply depots and warehouses. It is revealed that most accidents involve the employees who have less than one year’s service. Experience has proven that the preventive activities to avoid occupational traumatism are efficient when a complex of workplace safety measures is implemented. The experts consider the repeated and unscheduled training to be very important events. This is supported by the fact that among the employees of the commercial establishments who underwent repeated and unscheduled training, the number of individuals who suffered an accident is small. The efficient functioning of the occupational safety training system is infeasible without ensuring the motivation for assimilating the knowledge and forming the complete foundation for safe labor. In order to reduce the number of accidents, one should proceed from the principle of responding to accidents to the system for professional risk management.

  17. Correcting for multivariate measurement error by regression calibration in meta-analyses of epidemiological studies.

    NARCIS (Netherlands)

    Kromhout, D.

    2009-01-01

    Within-person variability in measured values of multiple risk factors can bias their associations with disease. The multivariate regression calibration (RC) approach can correct for such measurement error and has been applied to studies in which true values or independent repeat measurements of the

  18. Violation of the Sphericity Assumption and Its Effect on Type-I Error Rates in Repeated Measures ANOVA and Multi-Level Linear Models (MLM).

    Science.gov (United States)

    Haverkamp, Nicolas; Beauducel, André

    2017-01-01

    We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The

  19. Repeat immigration: A previously unobserved source of heterogeneity?

    Science.gov (United States)

    Aradhya, Siddartha; Scott, Kirk; Smith, Christopher D

    2017-07-01

    Register data allow for nuanced analyses of heterogeneities between sub-groups which are not observable in other data sources. One heterogeneity for which register data is particularly useful is in identifying unique migration histories of immigrant populations, a group of interest across disciplines. Years since migration is a commonly used measure of integration in studies seeking to understand the outcomes of immigrants. This study constructs detailed migration histories to test whether misclassified migrations may mask important heterogeneities. In doing so, we identify a previously understudied group of migrants called repeat immigrants, and show that they differ systematically from permanent immigrants. In addition, we quantify the degree to which migration information is misreported in the registers. The analysis is carried out in two steps. First, we estimate income trajectories for repeat immigrants and permanent immigrants to understand the degree to which they differ. Second, we test data validity by cross-referencing migration information with changes in income to determine whether there are inconsistencies indicating misreporting. From the first part of the analysis, the results indicate that repeat immigrants systematically differ from permanent immigrants in terms of income trajectories. Furthermore, income trajectories differ based on the way in which years since migration is calculated. The second part of the analysis suggests that misreported migration events, while present, are negligible. Repeat immigrants differ in terms of income trajectories, and may differ in terms of other outcomes as well. Furthermore, this study underlines that Swedish registers provide a reliable data source to analyze groups which are unidentifiable in other data sources.

  20. Receptionist input to quality and safety in repeat prescribing in UK general practice: ethnographic case study.

    Science.gov (United States)

    Swinglehurst, Deborah; Greenhalgh, Trisha; Russell, Jill; Myall, Michelle

    2011-11-03

    To describe, explore, and compare organisational routines for repeat prescribing in general practice to identify contributors and barriers to safety and quality. Ethnographic case study. Four urban UK general practices with diverse organisational characteristics using electronic patient records that supported semi-automation of repeat prescribing. 395 hours of ethnographic observation of staff (25 doctors, 16 nurses, 4 healthcare assistants, 6 managers, and 56 reception or administrative staff), and 28 documents and other artefacts relating to repeat prescribing locally and nationally. Potential threats to patient safety and characteristics of good practice. Observation of how doctors, receptionists, and other administrative staff contributed to, and collaborated on, the repeat prescribing routine. Analysis included mapping prescribing routines, building a rich description of organisational practices, and drawing these together through narrative synthesis. This was informed by a sociological model of how organisational routines shape and are shaped by information and communications technologies. Results Repeat prescribing was a complex, technology-supported social practice requiring collaboration between clinical and administrative staff, with important implications for patient safety. More than half of requests for repeat prescriptions were classed as "exceptions" by receptionists (most commonly because the drug, dose, or timing differed from what was on the electronic repeat list). They managed these exceptions by making situated judgments that enabled them (sometimes but not always) to bridge the gap between the idealised assumptions about tasks, roles, and interactions that were built into the electronic patient record and formal protocols, and the actual repeat prescribing routine as it played out in practice. This work was creative and demanded both explicit and tacit knowledge. Clinicians were often unaware of this input and it did not feature in policy

  1. Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study

    Directory of Open Access Journals (Sweden)

    Shruthi Acharya

    2015-01-01

    Full Text Available Context: The goal of any radiologist is to produce the highest quality diagnostic radiographs, while keeping patient exposure as low as reasonably achievable (ALARA. Aims: The aim of this study was to describe the reasons for radiograph rejections through a repeat film analysis in an Indian dental school. Settings and Design: An observational study conducted in the Department of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal. Materials and Methods: During a 6-month study period, a total of 9,495 intra-oral radiographs and 2339 extraoral radiographs taken in the Radiology Department were subjected to repeat film analysis. Statistical Analysis Used: SPSS Version 16. Descriptive analysis used. Results: The results showed that the repeat rates were 7.1% and 5.86% for intraoral and extraoral radiographs, respectively. Among the causes for errors reported, positioning error (38.7% was the most common, followed by improper angulations (26.1%, and improper film placement (11.2% for intra-oral radiographs. The study found that the maximum frequency of repeats among extraoral radiographs was for panoramic radiographs (49% followed by lateral cephalogram (33%, and paranasal sinus view (14%. It was also observed that repeat rate of intraoral radiographs was highest for internees (44.7%, and undergraduate students (28.2%. Conclusions: The study pointed to a need for more targeted interventions to achieve the goal of keeping patient exposure ALARA in a dental school setting.

  2. Magnetic Resonance Spectroscopy in Patients with Insomnia: A Repeated Measurement Study.

    Directory of Open Access Journals (Sweden)

    Kai Spiegelhalder

    Full Text Available Chronic insomnia is one of the most prevalent central nervous system disorders. It is characterized by increased arousal levels, however, the neurobiological causes and correlates of hyperarousal in insomnia remain to be further determined. In the current study, magnetic resonance spectroscopy was used in the morning and evening in a well-characterized sample of 20 primary insomnia patients (12 females; 8 males; 42.7 ± 13.4 years and 20 healthy good sleepers (12 females; 8 males; 44.1 ± 10.6 years. The most important inhibitory and excitatory neurotransmitters of the central nervous system, γ-aminobutyric acid (GABA and glutamate/glutamine (Glx, were assessed in the anterior cingulate cortex (ACC and dorsolateral prefrontal cortex (DLPFC. The primary hypothesis, a diurnal effect on GABA levels in patients with insomnia, could not be confirmed. Moreover, the current results did not support previous findings of altered GABA levels in individuals with insomnia. Exploratory analyses, however, suggested that GABA levels in the ACC may be positively associated with habitual sleep duration, and, thus, reduced GABA levels may be a trait marker of objective sleep disturbances. Moreover, there was a significant GROUP x MEASUREMENT TIME interaction effect on Glx in the DLPFC with increasing Glx levels across the day in the patients but not in the control group. Therefore, Glx levels may reflect hyperarousal at bedtime in those with insomnia. Future confirmatory studies should include larger sample sizes to investigate brain metabolites in different subgroups of insomnia.

  3. Beverage Intake Assessment Questionnaire: Relative Validity and Repeatability in a Spanish Population with Metabolic Syndrome from the PREDIMED-PLUS Study

    Science.gov (United States)

    Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi

    2016-01-01

    We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318

  4. Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Matricali, Giovanni A; Spaepen, Pieter; Meyer, Christophe; Desloovere, Kaat

    2012-07-01

    Repeatability studies on 3D multi-segment foot models (3DMFMs) have mainly considered healthy participants which contrasts with the widespread application of these models to evaluate foot pathologies. The current study aimed at establishing the repeatability of the 3DMFM described by Leardini et al. in presence of foot deformities. Foot kinematics of eight adult participants were analyzed using a repeated-measures design including two therapists with different levels of experience. The inter-trial variability was higher compared to the kinematics of healthy subjects. Consideration of relative angles resulted in the lowest inter-session variability. The absolute 3D rotations between the Sha-Cal and Cal-Met seem to have the lowest variability in both therapists. A general trend towards higher σ(sess)/σ(trial) ratios was observed when the midfoot was involved. The current study indicates that not only relative 3D rotations and planar angles can be measured consistently in patients, also a number of absolute parameters can be consistently measured serving as basis for the decision making process. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Quantum key distribution with two-segment quantum repeaters

    Energy Technology Data Exchange (ETDEWEB)

    Kampermann, Hermann; Abruzzo, Silvestre; Bruss, Dagmar [Theoretische Physik III, Heinrich-Heine-Universitaet Duesseldorf (Germany)

    2014-07-01

    Quantum repeaters represent one possible way to achieve long-distance quantum key distribution. One way of improving the repeater rate and decreasing the memory coherence time is the usage of multiplexing. Motivated by the experimental fact that long-range connections are practically demanding, we extend the analysis of the quantum repeater multiplexing protocol to the case of short-range connections. We derive formulas for the repeater rate and we show that short-range connections lead to most of the benefits of a full-range multiplexing protocol. A less demanding QKD-protocol without quantum memories was recently introduced by Lo et al. We generalize this measurement-device-independent quantum key Distribution protocol to the scenario where the repeater Station contains also heralded quantum memories. We assume either single-photon sources or weak coherent pulse sources plus decay states. We show that it is possible to significantly outperform the original proposal, even in presence of decoherence of the quantum memory. We give formulas in terms of device imperfections i.e., the quantum bit error rate and the repeater rate.

  6. Repeated DNA sequences in fungi

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, S K

    1974-11-01

    Several fungal species, representatives of all broad groups like basidiomycetes, ascomycetes and phycomycetes, were examined for the nature of repeated DNA sequences by DNA:DNA reassociation studies using hydroxyapatite chromatography. All of the fungal species tested contained 10 to 20 percent repeated DNA sequences. There are approximately 100 to 110 copies of repeated DNA sequences of approximately 4 x 10/sup 7/ daltons piece size of each. Repeated DNA sequence homoduplexes showed on average 5/sup 0/C difference of T/sub e/50 (temperature at which 50 percent duplexes dissociate) values from the corresponding homoduplexes of unfractionated whole DNA. It is suggested that a part of repetitive sequences in fungi constitutes mitochondrial DNA and a part of it constitutes nuclear DNA. (auth)

  7. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  8. Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.

    Science.gov (United States)

    Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L

    2012-04-01

    Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Factors influencing repeated teenage pregnancy: a review and meta-analysis.

    Science.gov (United States)

    Maravilla, Joemer C; Betts, Kim S; Couto E Cruz, Camila; Alati, Rosa

    2017-11-01

    .14-1.87), history of abortion (pooled odds ratio, 1.66; 95% confidence interval, 1.08-2.54), and relationship factors, such as partner support, increased the repeated teenage pregnancy risk. Contraceptive use, educational factors, depression, and a history of abortion are the highly influential predictors of repeated teenage pregnancy. However, there is a lack of epidemiologic studies in low- and middle-income countries to measure the extent and characteristics of repeated teenage pregnancy across more varied settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. THICKNESS OF THE MACULA, RETINAL NERVE FIBER LAYER, AND GANGLION CELL-INNER PLEXIFORM LAYER IN THE AGE-RELATED MACULAR DEGENERATION: The Repeatability Study of Spectral Domain Optical Coherence Tomography.

    Science.gov (United States)

    Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul

    2018-02-01

    To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.

  11. Automated genotyping of dinucleotide repeat markers

    Energy Technology Data Exchange (ETDEWEB)

    Perlin, M.W.; Hoffman, E.P. [Carnegie Mellon Univ., Pittsburgh, PA (United States)]|[Univ. of Pittsburgh, PA (United States)

    1994-09-01

    The dinucleotide repeats (i.e., microsatellites) such as CA-repeats are a highly polymorphic, highly abundant class of PCR-amplifiable markers that have greatly streamlined genetic mapping experimentation. It is expected that over 30,000 such markers (including tri- and tetranucleotide repeats) will be characterized for routine use in the next few years. Since only size determination, and not sequencing, is required to determine alleles, in principle, dinucleotide repeat genotyping is easily performed on electrophoretic gels, and can be automated using DNA sequencers. Unfortunately, PCR stuttering with these markers generates not one band for each allele, but a pattern of bands. Since closely spaced alleles must be disambiguated by human scoring, this poses a key obstacle to full automation. We have developed methods that overcome this obstacle. Our model is that the observed data is generated by arithmetic superposition (i.e., convolution) of multiple allele patterns. By quantitatively measuring the size of each component band, and exploiting the unique stutter pattern associated with each marker, closely spaced alleles can be deconvolved; this unambiguously reconstructs the {open_quotes}true{close_quotes} allele bands, with stutter artifact removed. We used this approach in a system for automated diagnosis of (X-linked) Duchenne muscular dystrophy; four multiplexed CA-repeats within the dystrophin gene were assayed on a DNA sequencer. Our method accurately detected small variations in gel migration that shifted the allele size estimate. In 167 nonmutated alleles, 89% (149/167) showed no size variation, 9% (15/167) showed 1 bp variation, and 2% (3/167) showed 2 bp variation. We are currently developing a library of dinucleotide repeat patterns; together with our deconvolution methods, this library will enable fully automated genotyping of dinucleotide repeats from sizing data.

  12. A COMPARISON OF PAIRS FIGURE SKATERS IN REPEATED JUMPS

    Directory of Open Access Journals (Sweden)

    William A. Sands

    2012-03-01

    Full Text Available Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare

  13. Does repeat Hb measurement within 2 hours after a normal initial Hb in stable trauma patients add value to trauma evaluation?

    NARCIS (Netherlands)

    Sierink, Joanne C.; Joosse, Pieter; de Castro, Steve M. M.; Schep, Niels W. L.; Goslings, J. Carel

    2014-01-01

    In our level I trauma center, it is considered common practice to repeat blood haemoglobin measurements in patients within 2 h after admission. However, the rationale behind this procedure is elusive and can be considered labour-intensive, especially in patients in whom haemorrhaging is not to be

  14. Repeat Colonoscopy within 6 Months after Initial Outpatient Colonoscopy in Ontario: A Population-Based Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Lawrence Paszat

    2017-01-01

    Full Text Available Background. The goal of this study is to examine utilization of early repeat colonoscopy ≤ 6 months after an index procedure. Methods. We identified persons having repeat colonoscopy ≤ 6 months following outpatient colonoscopy without prior colonoscopy ≤ 5 years or prior diagnosis of colorectal cancer (CRC. We modeled repeat colonoscopy using a generalized estimating equation with an exchangeable correlation structure to account for clustering of patients by endoscopist. Results. The population included 334,663 persons, 7,892 (2.36% of whom had an early repeat colonoscopy within 6 months. Overall, endoscopist prior year colonoscopy volume was inversely related to repeat ≤ 6 months. Repeat colonoscopy ≤ 6 months varied by the clinical setting of the index colonoscopy (adjusted OR = 1.41 (95% CI 1.29–1.55 at nonhospital facilities compared to teaching or community hospitals. Among those who had polypectomy or biopsy, the adjusted OR for early repeat ≤ 6 months was elevated among those whose index colonoscopy was at a nonhospital facility (OR 1.44, 95% CI 1.30–1.60, compared to those at a teaching hospital or community hospital. Conclusions. Repeat colonoscopy ≤ 6 months after an index procedure is associated with the clinical setting of the index colonoscopy.

  15. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  16. Accuracy of repeated kidney size estimation by ultrasonography and urography in children

    International Nuclear Information System (INIS)

    Hederstroem, E.; Forsberg, L.

    1985-01-01

    The accuracy of repeated sonographic and urographic kidney length measurements in kidney size evaluation was investigated in 80 children 0 to 14 years of age, mean age 4.5 years. At sonography 250 kidney lengths were compared. A difference of 0 to 1.0 cm in repeated length measurement was considered to be good accuracy and 94 per cent of right and 96 per cent of left kidney length were found within this interval-a better result than for urography with 76 per cent of repeated right kidney and 79 per cent of kidney lengths within the same interval (94 lengths). Both methods display a variation of kidney lengths which may lead to under- and overestimation of kidney size and growth. The investigation thus indicates good accuracy for repeated sonographic kidney size assessment which should be repeated often enough to estabilish a growth chart displaying the trend rather than rely too much on single measurements. Sonography can be highly recommended as a convenient and harmless alternative to urography. (orig.)

  17. [Study on causes and treatment of repeated vulvovaginitis in girlhood].

    Science.gov (United States)

    Zhang, Di-kai; Li, Xiu-yun; Yang, Dong-zi; Kuang, Jian-quan

    2006-07-01

    To explore the causes and treatment of repeated vulvovaginitis in girlhood in order to improve its prevention and treatment. Fifty-one girls with repeated vulvovaginitis (age vulvovaginitis and 14 ones (27%) suffering from posterior recto-vaginal fistula with in 51 patients. Five girls (10%) were smitten with vulval ulcer and 3 ones (6%) had been were found with vaginal foreign bodies. One girl (2%) was smitten with adhesion of labia minora. The vaginal discharges taken from 21 girls were cultured. Seventeen cases found bacteria. The positive rate of bacteria culture in the 21 cases reached 81%, in which, E.coli accounted for 5 cases (24%), staphylococcus and streptococcus accounted for 3 cases (14%) respectively. Patients suffering from non-specific vulvovaginitis and vulval ulcer accepted external lotion, antibiotic ointment or combining with antibiotics. Patients suffering from posterior recto-vaginal fistula accepted fistulectomy. Three girls who found vaginal foreign bodies took out of foreign bodies by hysteroscope. Fifty-one girls all were cured after appropriate therapy. Vulvovaginitis is the most common gynecologic diagnosis in girlhood. The principal cause of repeated invasion is non-specific vulvovaginitis and the secondly one is posterior recto-vaginal fistula. It need overhaul during the diagnosis. It is very availability to use hysteroscopy and do bacteria culture + antibiotic sensitivity test for repeated pediatric vulvovaginitis.

  18. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    Science.gov (United States)

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  19. Fostering repeat donations in Ghana.

    Science.gov (United States)

    Owusu-Ofori, S; Asenso-Mensah, K; Boateng, P; Sarkodie, F; Allain, J-P

    2010-01-01

    Most African countries are challenged in recruiting and retaining voluntary blood donors by cost and other complexities and in establishing and implementing national blood policies. The availability of replacement donors who are a cheaper source of blood has not enhanced repeat voluntary donor initiatives. An overview of activities for recruiting and retaining voluntary blood donors was carried out. Donor records from mobile sessions were reviewed from 2002 to 2008. A total of 71,701 blood donations; 45,515 (63.5%) being voluntary donations with 11,680 (25%) repeat donations were collected during the study period. Donations from schools and colleges contributed a steady 60% of total voluntary whilst radio station blood drives increased contribution from 10 to 27%. Though Muslim population is less than 20%, blood collection was above the 30-donation cost-effectiveness threshold with a repeat donation trend reaching 60%. In contrast Christian worshippers provided donations. Repeat donation trends amongst school donors and radio blood drives were 20% and 70% respectively. Repeat donations rates have been variable amongst different blood donor groups in Kumasi, Ghana. The impact of community leaders in propagating altruism cannot be overemphasized. Programs aiming at motivating replacement donors to be repeat donors should be developed and assessed. Copyright 2009 The International Association for Biologicals. All rights reserved.

  20. Comparative study of radioprotective properties of serotin derivatives repeatedly applied before gamma irradiation

    International Nuclear Information System (INIS)

    Gorelova, N.V.; Antipov, V.V.; Vasin, M.V.

    1977-01-01

    In the experiments on albino mice, the phenomenon of desensitization has been studied by a specific activity and some pharmacologic properties of serotonin, mexamin and 5-acetyloxytryptamine, the time-intervals between injections of the preparations being 5, 30 and 60 minutes, 2, 3, 4, 6, 8 and 24 hours. A correlation has been found between changes in radioprotective and pharmacologic properties (as determined by the accumulation of the dye in the splenic tissue) after repeated administration of mexamin. The phenomenon of desensitization is probably dependent not only on the chemical nature and mechanism of action of the protectors but also on the conditions under which they are repeatedly applied

  1. [Computer optical topography: a study of the repeatability of the results of human body model examination].

    Science.gov (United States)

    Sarnadskiĭ, V N

    2007-01-01

    The problem of repeatability of the results of examination of a plastic human body model is considered. The model was examined in 7 positions using an optical topograph for kyphosis diagnosis. The examination was performed under television camera monitoring. It was shown that variation of the model position in the camera view affected the repeatability of the results of topographic examination, especially if the model-to-camera distance was changed. A study of the repeatability of the results of optical topographic examination can help to increase the reliability of the topographic method, which is widely used for medical screening of children and adolescents.

  2. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    Science.gov (United States)

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  3. Hearing loss associated with repeated MRI acquisition procedure-related acoustic noise exposure: an occupational cohort study.

    Science.gov (United States)

    Bongers, Suzan; Slottje, Pauline; Kromhout, Hans

    2017-11-01

    To study the effects of repeated exposure to MRI-related acoustic noise during image acquisition procedures (scans) on hearing. A retrospective occupational cohort study was performed among workers of an MRI manufacturing facility (n=474). Longitudinal audiometry data from the facility's medical surveillance scheme collected from 1973 to 2010 were analysed by studying the association of cumulative exposure to MRI-related acoustic noise from voluntary (multiple) MRI scans and the hearing threshold of the volunteer. Repeated acoustic noise exposure during volunteer MRI scans was found to be associated with a small exposure-dependent increased rate change of hearing threshold level (dB/year), but the association was only found related to the number of voluntary MRI scans and not to modelled cumulative noise exposure (dB*hour) based on MRI-system type. The increased rate change of hearing threshold level was found to be statistically significant for the frequencies 500, 1000, 2000, 3000 and 4000 Hz in the right ear. From our longitudinal cohort study, it appeared that exposure to noise from voluntarily MRI scans may have resulted in a slight amount of hearing loss. Mandatory use of hearing protection might have prevented more severe hearing loss. Lack of consistency in findings between the left and right ears and between the two exposure measures prohibits definitive conclusions. Further research that addresses the study's methodological limitations is warranted to corroborate our findings. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  5. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  6. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    Science.gov (United States)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-04-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  7. Tools for analyzing genetic variants from sequencing data Case study: short tandem repeats

    OpenAIRE

    Gymrek, Melissa

    2016-01-01

    This was presented as a BitesizeBio Webinar entitled "Tools for analyzing genetic variants from sequencing data Case study: short tandem repeats"Accompanying scripts can be accessed on github:https://github.com/mgymrek/mgymrek-bitesizebio-webinar 

  8. Muscle Damage and Metabolic Responses to Repeated-Sprint Running With and Without Deceleration.

    Science.gov (United States)

    Minahan, Clare L; Poke, Daniel P; Morrison, Jaime; Bellinger, Phillip M

    2018-04-04

    Minahan, CL, Poke, DP, Morrison, J, and Bellinger, PM. Muscle damage and metabolic responses to repeated-sprint running with and without deceleration. J Strength Cond Res XX(X): 000-000, 2017-This study aimed to determine whether repeated-sprint running with deceleration aggravates markers of muscle damage or delays the recovery of performance compared with repeated-sprint running without deceleration. Fourteen male team-sport athletes performed 2 randomly ordered testing sessions on a nonmotorized treadmill with one session requiring participants to decelerate (TMd) within 4 seconds before stopping or immediately step to the side of the treadmill belt at the completion of each sprint (TMa). Peak and mean velocities, speed decrement, blood lactate concentrations, and oxygen uptake were monitored during the repeated-sprint running protocols. Countermovement vertical jump (CMJ) performance, perceived muscle soreness, sit-and-reach flexibility, plasma creatine kinase (CK), lactate dehydrogenase (LDH), and myoglobin (Mb) concentrations were quantified immediately before and after and 45 minutes, 24 and 48 hours after repeated-sprint running protocols. Although muscle damage was indicated by increases in CK, LDH, and Mb (p ≤ 0.05) in both groups, there was no significant effect of condition (TMa vs. TMd) on any of the measured performance or physiological variables (p > 0.05). The present study indicated that the removal of deceleration from repeated-sprint running on a nonmotorized treadmill has no effect on metabolism or performance during or after repeated-sprint running or markers of muscle damage.

  9. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Science.gov (United States)

    Reed, Katharine; Wood, Carly; Barton, Jo; Pretty, Jules N; Cohen, Daniel; Sandercock, Gavin R H

    2013-01-01

    Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run) and self-reported physical activity (PAQ-A) in 11 and 12 year olds (n = 75). Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE) and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74), = 12.2, pself-esteem following exercise but there was no condition by exercise interaction (F (1,74), = 0.13, p = 0.72). There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04) between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55). Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  10. Initial study of stability and repeatability of measuring R2' and oxygen extraction fraction values in the healthy brain with gradient-echo sampling of spin-echo sequence

    International Nuclear Information System (INIS)

    Hui Lihong; Zhang Xiaodong; He Chao; Xie Sheng; Xiao Jiangxi; Zhang jue; Wang Xiaoying; Jiang Xuexiang

    2010-01-01

    Objective: To evaluate the stability and repeatability of gradient-echo sampling of spin- echo (GESSE) sequence in measuring the R 2 ' value in volunteers, by comparison with traditional GRE sequence (T 2 * ]nap and T 2 map). Methods: Eight normal healthy volunteers were enrolled in this study and written informed consents were obtained from all subjects. MR scanning including sequences of GESSE, T 2 map and T 2 * map were performed in these subjects at resting status. The same protocol was repeated one day later. Raw data from GESSE sequence were transferred to PC to conduct postprocessing with the software built in house. R 2 ' map and OEF map were got consequently. To obtain quantitative R 2 ' and OEF values in the brain parenchyma, six ROIs were equally placed in the anterior, middle and posterior part of bilateral hemispheres. Both mean and standard deviation of R 2 ' and OEF were recorded. All images from T 2 * map and T 2 map were transferred to the Workstation for postprocessing. The ROIs were put at the same areas as those for GESSE sequence. R 2 ' is defined as R 2 ' = R 2 * - R 2 , R 2 * = 1/T 2 * . The R 2 ' value of GESSE sequence were compared with that of GRE sequence. Results: The mean R 2 ' values of GESSE at the first and second scan and those of the GRE were (4.21±0.92), (4.45±0.94) Hz and (7.37±1.47), (6.42±2.33) Hz respectively. The mean OEF values of GESSE at the first and second scan is 0.327±0.036 and 0.336± 0.035 respectively. The R 2 ' value and OEF value obtained from GESSE were not significantly different between the first and second scan (t=-0.83, -1.48, P>0.05). The R 2 ' value of first GRE imaging had significantly statistical difference from that of second GRE imaging (t=1.80, P 2 ' value of GESSE sequence was less than that of GRE sequence, and there was significantly statistical difference between them (t=1.71, P<0.05). Conclusion: The GESSE sequence has good stability and repeatability with promising clinical practicability

  11. Safety of Repeated Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Louie, John D.; Iagaru, Andrei H.; Goris, Michael L.; Sze, Daniel Y.

    2013-01-01

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver’s cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51–71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction

  12. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  13. Who Repeats Algebra, and How Does Initial Performance Relate to Improvement When the Course Is Repeated?

    Science.gov (United States)

    Fong, Anthony; Jaquet, Karina; Finkelstein, Neal

    2016-01-01

    The information provided in this report shows how students perform when they repeat algebra I and how the level of improvement varies depending on initial course performance and the academic measure (course grades or CST scores). This information can help inform decisions and policies regarding whether and under what circumstances students should…

  14. The importance of position and path repeatability on force at the knee during six-DOF joint motion.

    Science.gov (United States)

    Darcy, Shon P; Gil, Jorge E; Woo, Savio L-Y; Debski, Richard E

    2009-06-01

    Mechanical devices, such as robotic manipulators have been designed to measure joint and ligament function because of their ability to position a diarthrodial joint in six degrees-of-freedom with fidelity. However, the precision and performance of these testing devices vary. Therefore, the objective of this study was to determine the effect of systematic errors in position and path repeatability of two high-payload robotic manipulators (Manipulators 1 and 2) on the resultant forces at the knee. Using a porcine knee, the position and path repeatability of these manipulators were determined during passive flexion-extension with a coordinate measuring machine. The position repeatability of Manipulator 1 was 0.3 mm in position and 0.2 degrees in orientation while Manipulator 2 had a better position repeatability of 0.1 mm in position and 0.1 degrees in orientation throughout the range of positions examined. The corresponding variability in the resultant force at the knee for these assigned positions was 32+/-33 N for Manipulator 1 and 4+/-1 N for Manipulator 2. Furthermore, the repeatability of the trajectory of each manipulator while moving between assigned positions (path repeatability) was 0.8 mm for Manipulator 1 while the path repeatability for Manipulator 2 was improved (0.1 mm). These path discrepancies produced variability in the resultant force at the knee of 44+/-24 and 21+/-8 N, respectively, for Manipulators 1 and 2 primarily due to contact between the articular surfaces of the tibia and femur. Therefore, improved position and path repeatability yields lower variability in the resultant forces at the knee. Although position repeatability has been the most common criteria for evaluating biomechanical testing devices, the current study has clearly demonstrated that path repeatability can have an even larger effect on the variability in resultant force at the knee. Consequently, the repeatability of the path followed by the joint throughout its prescribed

  15. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  16. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  17. Implementation of repeat HIV testing during pregnancy in Kenya: a qualitative study.

    Science.gov (United States)

    Rogers, Anna Joy; Weke, Elly; Kwena, Zachary; Bukusi, Elizabeth A; Oyaro, Patrick; Cohen, Craig R; Turan, Janet M

    2016-07-11

    Repeat HIV testing in late pregnancy has the potential to decrease rates of mother-to-child transmission of HIV by identifying mothers who seroconvert after having tested negative for HIV in early pregnancy. Despite being national policy in Kenya, the available data suggest that implementation rates are low. We conducted 20 in-depth semi-structured interviews with healthcare providers and managers to explore barriers and enablers to implementation of repeat HIV testing guidelines for pregnant women. Participants were from the Nyanza region of Kenya and were purposively selected to provide variation in socio-demographics and job characteristics. Interview transcripts were coded and analyzed in Dedoose software using a thematic analysis approach. Four themes were identified a priori using Ferlie and Shortell's Framework for Change and additional themes were allowed to emerge from the data. Participants identified barriers and enablers at the client, provider, facility, and health system levels. Key barriers at the client level from the perspective of providers included late initial presentation to antenatal care and low proportions of women completing the recommended four antenatal visits. Barriers to offering repeat HIV testing for providers included heavy workloads, time limitations, and failing to remember to check for retest eligibility. At the facility level, inconsistent volume of clients and lack of space required for confidential HIV retesting were cited as barriers. Finally, at the health system level, there were challenges relating to the HIV test kit supply chain and the design of nationally standardized antenatal patient registers. Enablers to improving the implementation of repeat HIV testing included client dissemination of the benefits of antenatal care through word-of-mouth, provider cooperation and task shifting, and it was suggested that use of an electronic health record system could provide automatic reminders for retest eligibility. This study

  18. Governing conditions of repeatable Barkhausen noise response

    International Nuclear Information System (INIS)

    Stupakov, O.; Pal'a, J.; Takagi, T.; Uchimoto, T.

    2009-01-01

    The paper is devoted to the establishment of experimental conditions, which ensure the repeatability of magnetic Barkhausen noise testing in practice. For this task, the measurements were performed on open flat samples using different experimental configurations, including: different magnetization frequencies, sampling rates, and filter cut-off frequencies; using a sample-wrapped coil and using attached pick-up coils of various dimensions, with different lift-offs of a single yoke magnet and of the attached coil. The sample magnetization was controlled by a vertical array of three Hall sensors; their readings were extrapolated to the sample surface to precisely define its field. After analysis of the results, a scheme for an optimized sensor with a controlled field waveform was suggested to improve the measurement repeatability. The important issues of signal processing and parameter applicability were also discussed in detail.

  19. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    International Nuclear Information System (INIS)

    Bagchi, Manjari

    2017-01-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  20. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Bagchi, Manjari, E-mail: manjari@imsc.res.in [The Institute of Mathematical Sciences (IMSc-HBNI), 4th Cross Road, CIT Campus, Taramani, Chennai 600113 (India)

    2017-04-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  1. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  2. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    Science.gov (United States)

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  3. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  4. Repeated vertebral augmentation for new vertebral compression fractures of postvertebral augmentation patients: a nationwide cohort study

    Directory of Open Access Journals (Sweden)

    Liang CL

    2015-03-01

    Full Text Available Cheng-Loong Liang,1 Hao-Kwan Wang,1 Fei-Kai Syu,2 Kuo-Wei Wang,1 Kang Lu,1 Po-Chou Liliang1 1Department of Neurosurgery, E-Da Hospital, I-Shou University, Kaohsiung City, Taiwan; 2Department of Pharmacy, China Medical University Hospital, Taichung City, Taiwan Purpose: Postvertebral augmentation vertebral compression fractures are common; repeated vertebral augmentation is usually performed for prompt pain relief. This study aimed to evaluate the incidence and risk factors of repeat vertebral augmentation.Methods: We performed a retrospective, nationwide, population-based longitudinal observation study, using the National Health Insurance Research Database (NHIRD of Taiwan. All patients who received vertebral augmentation for vertebral compression fractures were evaluated. The collected data included patient characteristics (demographics, comorbidities, and medication exposure and repeat vertebral augmentation. Kaplan–Meier and stratified Cox proportional hazard regressions were performed for analyses.Results: The overall incidence of repeat vertebral augmentation was 11.3% during the follow-up until 2010. Patients with the following characteristics were at greater risk for repeat vertebral augmentation: female sex (AOR=1.24; 95% confidence interval [CI]: 1.10–2.36, advanced age (AOR=1.60; 95% CI: 1.32–2.08, diabetes mellitus (AOR=4.31; 95% CI: 4.05–5.88, cerebrovascular disease (AOR=4.09; 95% CI: 3.44–5.76, dementia (AOR=1.97; 95% CI: 1.69–2.33, blindness or low vision (AOR=3.72; 95% CI: 2.32–3.95, hypertension (AOR=2.58; 95% CI: 2.35–3.47, and hyperlipidemia (AOR=2.09; 95% CI: 1.67–2.22. Patients taking calcium/ vitamin D (AOR=2.98; 95% CI: 1.83–3.93, bisphosphonates (AOR=2.11; 95% CI: 1.26–2.61, or calcitonin (AOR=4.59; 95% CI: 3.40–5.77 were less likely to undergo repeat vertebral augmentation; however, those taking steroids (AOR=7.28; 95% CI: 6.32–8.08, acetaminophen (AOR=3.54; 95% CI: 2.75–4.83, or nonsteroidal

  5. Muscle damage and repeated bout effect induced by enhanced eccentric squats.

    Science.gov (United States)

    Coratella, Giuseppe; Chemello, Alessandro; Schena, Federico

    2016-12-01

    Muscle damage and repeated bout effect have been studied after pure eccentric-only exercise. The aim of this study was to evaluate muscle damage and repeated bout effect induced by enhanced eccentric squat exercise using flywheel device. Thirteen healthy males volunteered for this study. Creatine kinase blood activity (CK), quadriceps isometric peak torque and muscle soreness were used as markers of muscle damage. The dependent parameters were measured at baseline, immediately after and each day up to 96 hours after the exercise session. The intervention consisted of 100 repetitions of enhanced eccentric squat exercise using flywheel device. The same protocol was repeated after 4 weeks. After the first bout, CK and muscle soreness were significantly greater (P0.05), while isometric peak torque and muscle soreness returned to values similar to baseline after respectively 48 and 72 hours. All muscle damage markers were significantly lower after second compared to first bout. The enhanced eccentric exercise induced symptoms of muscle damage up to 96 hours. However, it provided muscle protection after the second bout, performed four weeks later. Although it was not eccentric-only exercise, the enhancement of eccentric phase provided muscle protection.

  6. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  7. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  8. Control of coercive field in lithium niobate crystals with repeated polarization reversal

    International Nuclear Information System (INIS)

    Ro, Jung Hoon; Jeong, Doun; Park, Taeyong; Kim, Chulhan; Kwon, Soon-Bok; Cha, Myoungsik; Choi, Byeong Cheol; Yu, Nanei; Kurimura, Sunao; Jeon, Gyerok

    2005-01-01

    In this study, the amount of decrease in coercive field of congruent lithium niobate during repeated poling and back-poling was measured. The polarization is reversed in 300 ms and then back-poled during the rest period. The coercive field can be decreased around 1 kV/mm with a repeated poling interval of 5 s. As the interval prolonged, the poling field decrease became smaller, and a stretched exponential function is suggested for the experimental fitting resulting in a set of meaningful parameters. These values are essential for the design of high quality domain engineering

  9. Digital repeat analysis; setup and operation.

    Science.gov (United States)

    Nol, J; Isouard, G; Mirecki, J

    2006-06-01

    Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.

  10. Repeat profile analysis in an x-ray department

    International Nuclear Information System (INIS)

    Bassey, C.E.; Ojo, O.O.; Akpabio, I.

    1991-01-01

    The repeat profile of an x-ray department in a developing country was analysed monthly between July 1989 and June 1990. Results showed an average repeat rate of 3.7% for the period of study. The main causes of film repetition were: equipment fault, 33.9%; radiographer's fault, 27.4%; film fault, 19.3%; processing fault, 10.8% and patient's fault, 8.6%. The average repeat rate in the first 6 months of study reduced by 50% in the last 6 months. This was due to the effectiveness of implementation of corrective actions. The overall repeat rate was found to correlate well with both the equipment fault and radiographer's fault with correlation coefficients, r, of 0.94 and 0.91, respectively. It is expected that a further reduction in the repeat rate will be obtained after the introduction of quality assurance programmes. (author)

  11. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    Science.gov (United States)

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  12. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  13. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  14. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    Science.gov (United States)

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  16. Potential Role of the Last Half Repeat in TAL Effectors Revealed by a Molecular Simulation Study

    Directory of Open Access Journals (Sweden)

    Hua Wan

    2016-01-01

    Full Text Available TAL effectors (TALEs contain a modular DNA-binding domain that is composed of tandem repeats. In all naturally occurring TALEs, the end of tandem repeats is invariantly a truncated half repeat. To investigate the potential role of the last half repeat in TALEs, we performed comparative molecular dynamics simulations for the crystal structure of DNA-bound TALE AvrBs3 lacking the last half repeat and its modeled structure having the last half repeat. The structural stability analysis indicates that the modeled system is more stable than the nonmodeled system. Based on the principle component analysis, it is found that the AvrBs3 increases its structural compactness in the presence of the last half repeat. The comparison of DNA groove parameters of the two systems implies that the last half repeat also causes the change of DNA major groove binding efficiency. The following calculation of hydrogen bond reveals that, by stabilizing the phosphate binding with DNA at the C-terminus, the last half repeat helps to adopt a compact conformation at the protein-DNA interface. It further mediates more contacts between TAL repeats and DNA nucleotide bases. Finally, we suggest that the last half repeat is required for the high-efficient recognition of DNA by TALE.

  17. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  18. Construction and updating of a public events questionnaire for repeated measures longitudinal studies

    Directory of Open Access Journals (Sweden)

    Martha eNoone

    2014-03-01

    Full Text Available Impairments of retrospective memory and cases of retrograde amnesia are often seen in clinical settings. A measure of the proportion of memories retained over a specified time can be useful in clinical situations and public events questionnaires may be valuable in this respect. However, consistency of retention of public events memory has rarely been studied in the same participants. In addition, when used in a research context, public events questionnaires require updating to ensure questions are of equivalent age with respect to when the test is taken. This paper describes an approach to constructing and updating a Public Events Questionnaire (PEQ for use with a sample that is recruited and followed-up over a long time-period. Internal consistency, parallel-form reliability, test-retest reliability and secondary validity analyses were examined for three versions of the PEQ that were updated every six months. Versions 2 and 3 of the questionnaire were reliable across and within versions and for recall and recognition. Change over time was comparable across each version of the PEQ. These results show that PEQs can be regularly updated in a standardised fashion to allow use throughout studies with long recruitment periods.

  19. Construction and updating of a public events questionnaire for repeated measures longitudinal studies.

    Science.gov (United States)

    Noone, Martha; Semkovska, Maria; Carton, Mary; Dunne, Ross; Horgan, John-Paul; O'Kane, Breige; McLoughlin, Declan M

    2014-01-01

    Impairments of retrospective memory and cases of retrograde amnesia are often seen in clinical settings. A measure of the proportion of memories retained over a specified time can be useful in clinical situations and public events questionnaires may be valuable in this respect. However, consistency of retention of public events memory has rarely been studied in the same participants. In addition, when used in a research context, public events questionnaires require updating to ensure questions are of equivalent age with respect to when the test is taken. This paper describes an approach to constructing and updating a Public Events Questionnaire (PEQ) for use with a sample that is recruited and followed-up over a long time-period. Internal consistency, parallel-form reliability, test-retest reliability, and secondary validity analyses were examined for three versions of the PEQ that were updated every 6 months. Versions 2 and 3 of the questionnaire were reliable across and within versions and for recall and recognition. Change over time was comparable across each version of the PEQ. These results show that PEQs can be regularly updated in a standardized fashion to allow use throughout studies with long recruitment periods.

  20. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  1. Long-term repeatability of the skin prick test is high when supported by history or allergen-sensitivity tests

    DEFF Research Database (Denmark)

    Bødtger, Uffe; Jacobsen, C R; Poulsen, L K

    2003-01-01

    subjects. An SPT was positive when > or =3 mm, and repeatable if either persistently positive or negative. Clinical sensitivity to birch pollen was used as model for inhalation allergy, and was investigated at inclusion and at study termination by challenge tests, intradermal test, titrated SPT and Ig......E measurements. Birch pollen symptoms were confirmed in diaries. RESULTS: The repeatability of a positive SPT was 67%, increasing significantly to 100% when supported by the history. When not supported by history, the presence of specific IgE was significantly associated with a repeatable SPT. Allergen....... CONCLUSION: SPT changes are clinically relevant. Further studies using other allergens are needed. Long-term repeatability of SPT is high in the presence of a supportive history....

  2. Metamemory judgments and the benefits of repeated study: improving recall predictions through the activation of appropriate knowledge.

    Science.gov (United States)

    Tiede, Heather L; Leboe, Jason P

    2009-05-01

    Correspondence between judgments of learning (JOLs) and actual recall tends to be poor when the same items are studied and recalled multiple times (e.g., A. Koriat, L. Sheffer, & H. Ma'ayan, 2002). The authors investigated whether making relevant metamemory knowledge more salient would improve the association between actual and predicted recall as a function of repeated exposure to the same study list. In 2 experiments, participants completed 4 study-recall phases involving the same list of items. In addition to having participants make item-by-item JOLs during each study phase, after the 1st study-recall phase participants also generated change-in-recall estimates as to how many more or fewer words they would recall given another exposure to the same study list. This estimation procedure was designed to highlight repeated study as a factor that can contribute to recall performance. Activating metamemory knowledge about the benefits of repeated study for recall in this way allowed participants to accurately express this knowledge in a free-recall context (Experiment 2), but less so when the memory test was cued recall (Experiment 1). Copyright 2009 APA, all rights reserved.

  3. Dental Fear in Children with Repeated Tooth Injuries.

    Science.gov (United States)

    Negovetić Vranić, Dubravka; Ivančić Jokić, Nataša; Bakarčić, Danko; Carek, Andreja; Rotim, Željko; Verzak, Željko

    2016-06-01

    Tooth injuries are serious clinical conditions. Some children experience dental trauma only once, while others are more prone to repeated tooth injuries. Repeated dental trauma occurs in 19.4% to 30% of patients. Pain and dental trauma are the most common reasons for fear and anxiety. The main objective of this study was to investigate how dental trauma, as well as repeated dental trauma affects the occurrence and development of dental fear in children. The study was conducted on a random sample of 147 subjects (88 boys and 59 girls) aged 5-8 and 9-12 years. Subjects in both age groups were divided into subroups without dental trauma, with one dental trauma and with repeated dental trauma. The validated Children’s Fear Survey Schedule – Dental Subscale was used on fear assessment. Results showed that only 12.2% of children without trauma, 33.3% with one trauma and 51.7% with repeated trauma were not afraid of injection. Older children had a significantly lower fear of injections, touch of an unknown person, choking, going to the hospital and people in white uniforms. Dentist was not the cause of fear in 65.5% of patients with repeated trauma. With each repeated injury of teeth, the degree of their fear of dental treatment was lower.

  4. The development of the micro-solid propellant thruster array with improved repeatability

    International Nuclear Information System (INIS)

    Seo, Daeban; Kwon, Sejin; Lee, Jongkwang

    2012-01-01

    This paper presents the development of a micro-solid propellant thruster array with improved repeatability. The repeatability and low performance variation of each thruster unit with a high ignition success rate is essential in micro-solid propellant thruster array. To date, the study on the improvement of the repeatability has not yet been reported. As the first step for this study, we propose a new type of micro igniter, using a glass wafer called the heater-contact micro igniter. This igniter is also designed to improve the ignition characteristics of a glass-based micro igniter. The prototype of the igniter array is designed and fabricated to establish its fabrication process and to conduct its performance evaluation. Through the firing test, the performance of the heater-contact micro igniter is verified. The 5 × 5 sized micro-solid propellant thruster array is designed and fabricated applying the developed heater-contact igniter. The measured average thrust of each thruster unit is 2.542 N, and calculated standard deviation is 0.369 N. The calculated average total impulse and its standard deviation are 0.182 and 0.04 mNs, respectively. Based on these results, the improvement of repeatability is verified. Finally, the ignition control system of the micro-thruster array is developed. (paper)

  5. ATXN2 trinucleotide repeat length correlates with risk of ALS.

    Science.gov (United States)

    Sproviero, William; Shatunov, Aleksey; Stahl, Daniel; Shoai, Maryam; van Rheenen, Wouter; Jones, Ashley R; Al-Sarraj, Safa; Andersen, Peter M; Bonini, Nancy M; Conforti, Francesca L; Van Damme, Philip; Daoud, Hussein; Del Mar Amador, Maria; Fogh, Isabella; Forzan, Monica; Gaastra, Ben; Gellera, Cinzia; Gitler, Aaron D; Hardy, John; Fratta, Pietro; La Bella, Vincenzo; Le Ber, Isabelle; Van Langenhove, Tim; Lattante, Serena; Lee, Yi-Chung; Malaspina, Andrea; Meininger, Vincent; Millecamps, Stéphanie; Orrell, Richard; Rademakers, Rosa; Robberecht, Wim; Rouleau, Guy; Ross, Owen A; Salachas, Francois; Sidle, Katie; Smith, Bradley N; Soong, Bing-Wen; Sorarù, Gianni; Stevanin, Giovanni; Kabashi, Edor; Troakes, Claire; van Broeckhoven, Christine; Veldink, Jan H; van den Berg, Leonard H; Shaw, Christopher E; Powell, John F; Al-Chalabi, Ammar

    2017-03-01

    We investigated a CAG trinucleotide repeat expansion in the ATXN2 gene in amyotrophic lateral sclerosis (ALS). Two new case-control studies, a British dataset of 1474 ALS cases and 567 controls, and a Dutch dataset of 1328 ALS cases and 691 controls were analyzed. In addition, to increase power, we systematically searched PubMed for case-control studies published after 1 August 2010 that investigated the association between ATXN2 intermediate repeats and ALS. We conducted a meta-analysis of the new and existing studies for the relative risks of ATXN2 intermediate repeat alleles of between 24 and 34 CAG trinucleotide repeats and ALS. There was an overall increased risk of ALS for those carrying intermediate sized trinucleotide repeat alleles (odds ratio 3.06 [95% confidence interval 2.37-3.94]; p = 6 × 10 -18 ), with an exponential relationship between repeat length and ALS risk for alleles of 29-32 repeats (R 2  = 0.91, p = 0.0002). No relationship was seen for repeat length and age of onset or survival. In contrast to trinucleotide repeat diseases, intermediate ATXN2 trinucleotide repeat expansion in ALS does not predict age of onset but does predict disease risk. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  6. Study of simple sequence repeat (SSR) polymorphism for biotic ...

    African Journals Online (AJOL)

    home

    2013-10-02

    Oct 2, 2013 ... G. Siva Kumar1, K. Aruna Kumari1*, Ch. V. Durga Rani1, R. M. Sundaram2, S. Vanisree3, Md. ..... review by Jena and Mackill (2008) provided the list of .... repeat protein and is a member of a resistance gene cluster on rice.

  7. Measuring taste impairment in epidemiologic studies: the Beaver Dam Offspring Study.

    Science.gov (United States)

    Cruickshanks, K J; Schubert, C R; Snyder, D J; Bartoshuk, L M; Huang, G H; Klein, B E K; Klein, R; Nieto, F J; Pankow, J S; Tweed, T S; Krantz, E M; Moy, G S

    2009-07-01

    Taste or gustatory function may play an important role in determining diet and nutritional status and therefore indirectly impact health. Yet there have been few attempts to study the spectrum of taste function and dysfunction in human populations. Epidemiologic studies are needed to understand the impact of taste function and dysfunction on public health, to identify modifiable risk factors, and to develop and test strategies to prevent clinically significant dysfunction. However, measuring taste function in epidemiologic studies is challenging and requires repeatable, efficient methods that can measure change over time. Insights gained from translating laboratory-based methods to a population-based study, the Beaver Dam Offspring Study (BOSS) will be shared. In this study, a generalized labeled magnitude scale (gLMS) method was used to measure taste intensity of filter paper disks saturated with salt, sucrose, citric acid, quinine, or 6-n-propylthiouracil, and a gLMS measure of taste preferences was administered. In addition, a portable, inexpensive camera system to capture digital images of fungiform papillae and a masked grading system to measure the density of fungiform papillae were developed. Adult children of participants in the population-based Epidemiology of Hearing Loss Study in Beaver Dam, Wisconsin, are eligible for this ongoing study. The parents were residents of Beaver Dam and 43-84 years of age in 1987-1988; offspring ranged in age from 21-84 years in 2005-2008. Methods will be described in detail and preliminary results about the distributions of taste function in the BOSS cohort will be presented.

  8. Comparison of two techniques for assessing the shaping efficacy of repeatedly used nickel-titanium rotary instruments.

    Science.gov (United States)

    Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone

    2011-06-01

    The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. The leucine-rich repeat structure.

    Science.gov (United States)

    Bella, J; Hindle, K L; McEwan, P A; Lovell, S C

    2008-08-01

    The leucine-rich repeat is a widespread structural motif of 20-30 amino acids with a characteristic repetitive sequence pattern rich in leucines. Leucine-rich repeat domains are built from tandems of two or more repeats and form curved solenoid structures that are particularly suitable for protein-protein interactions. Thousands of protein sequences containing leucine-rich repeats have been identified by automatic annotation methods. Three-dimensional structures of leucine-rich repeat domains determined to date reveal a degree of structural variability that translates into the considerable functional versatility of this protein superfamily. As the essential structural principles become well established, the leucine-rich repeat architecture is emerging as an attractive framework for structural prediction and protein engineering. This review presents an update of the current understanding of leucine-rich repeat structure at the primary, secondary, tertiary and quaternary levels and discusses specific examples from recently determined three-dimensional structures.

  10. Repeatability and consistency of individual behaviour in juvenile and adult Eurasian harvest mice

    Science.gov (United States)

    Schuster, Andrea C.; Carl, Teresa; Foerster, Katharina

    2017-04-01

    Knowledge on animal personality has provided new insights into evolutionary biology and animal ecology, as behavioural types have been shown to affect fitness. Animal personality is characterized by repeatable and consistent between-individual behavioural differences throughout time and across different situations. Behavioural repeatability within life history stages and consistency between life history stages should be checked for the independence of sex and age, as recent data have shown that males and females in some species may differ in the repeatability of behavioural traits, as well as in their consistency. We measured the repeatability and consistency of three behavioural and one cognitive traits in juvenile and adult Eurasian harvest mice ( Micromys minutus). We found that exploration, activity and boldness were repeatable in juveniles and adults. Spatial recognition measured in a Y Maze was only repeatable in adult mice. Exploration, activity and boldness were consistent before and after maturation, as well as before and after first sexual contact. Data on spatial recognition provided little evidence for consistency. Further, we found some evidence for a litter effect on behaviours by comparing different linear mixed models. We concluded that harvest mice express animal personality traits as behaviours were repeatable across sexes and consistent across life history stages. The tested cognitive trait showed low repeatability and was less consistent across life history stages. Given the rising interest in individual variation in cognitive performance, and in its relationship to animal personality, we suggest that it is important to gather more data on the repeatability and consistency of cognitive traits.

  11. Secondhand tobacco smoke exposure and heart rate variability and inflammation among non-smoking construction workers: a repeated measures study.

    Science.gov (United States)

    Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M

    2013-10-02

    Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated

  12. Repeatability of chemical-shift-encoded water-fat MRI and diffusion-tensor imaging in lower extremity muscles in children.

    Science.gov (United States)

    Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente

    2014-06-01

    The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.

  13. Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology.

    Science.gov (United States)

    McAlinden, Colm; Khadka, Jyoti; Pesudovs, Konrad

    2011-07-01

    The ever-expanding choice of ocular metrology and imaging equipment has driven research into the validity of their measurements. Consequently, studies of the agreement between two instruments or clinical tests have proliferated in the ophthalmic literature. It is important that researchers apply the appropriate statistical tests in agreement studies. Correlation coefficients are hazardous and should be avoided. The 'limits of agreement' method originally proposed by Altman and Bland in 1983 is the statistical procedure of choice. Its step-by-step use and practical considerations in relation to optometry and ophthalmology are detailed in addition to sample size considerations and statistical approaches to precision (repeatability or reproducibility) estimates. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  14. Ten days of repeated local forearm heating does not affect cutaneous vascular function.

    Science.gov (United States)

    Francisco, Michael A; Brunt, Vienna E; Jensen, Krista Nicole; Lorenzo, Santiago; Minson, Christopher T

    2017-08-01

    The aim of the present study was to determine whether 10 days of repeated local heating could induce peripheral adaptations in the cutaneous vasculature and to investigate potential mechanisms of adaptation. We also assessed maximal forearm blood flow to determine whether repeated local heating affects maximal dilator capacity. Before and after 10 days of heat training consisting of 1-h exposures of the forearm to 42°C water or 32°C water (control) in the contralateral arm (randomized and counterbalanced), we assessed hyperemia to rapid local heating of the skin ( n = 14 recreationally active young subjects). In addition, sequential doses of acetylcholine (ACh, 1 and 10 mM) were infused in a subset of subjects ( n = 7) via microdialysis to study potential nonthermal microvascular adaptations following 10 days of repeated forearm heat training. Skin blood flow was assessed using laser-Doppler flowmetry, and cutaneous vascular conductance (CVC) was calculated as laser-Doppler red blood cell flux divided by mean arterial pressure. Maximal cutaneous vasodilation was achieved by heating the arm in a water-spray device for 45 min and assessed using venous occlusion plethysmography. Forearm vascular conductance (FVC) was calculated as forearm blood flow divided by mean arterial pressure. Repeated forearm heating did not increase plateau percent maximal CVC (CVC max ) responses to local heating (89 ± 3 vs. 89 ± 2% CVC max , P = 0.19), 1 mM ACh (43 ± 9 vs. 53 ± 7% CVC max , P = 0.76), or 10 mM ACh (61 ± 9 vs. 85 ± 7% CVC max , P = 0.37, by 2-way repeated-measures ANOVA). There was a main effect of time at 10 mM ACh ( P = 0.03). Maximal FVC remained unchanged (0.12 ± 0.02 vs. 0.14 ± 0.02 FVC, P = 0.30). No differences were observed in the control arm. Ten days of repeated forearm heating in recreationally active young adults did not improve the microvascular responsiveness to ACh or local heating. NEW & NOTEWORTHY We show for the first time that 10 days of repeated

  15. Evidence of radiation-induced reduction of height and body weight from repeated measurements of adults exposed in childhood to the atomic bombs

    International Nuclear Information System (INIS)

    Otake, Masanori; Funamoto, Sachiyo; Fujikoshi, Yasunori; Schull, W.J.

    1994-01-01

    Reduction of growth from exposure to atomic bomb radiation has been examined using individuals under 10 years old at the time of the bombing (ATB) and a growth curve analysis based on measurements of height and weight made in the course of the 4th-7th cycles of the Adult Health Study examinations (1964-1972). As expected, the largest difference in growth to emerge is between males and females. However, a highly significant reduction of growth associated with dose (DS86) was observed among those survivors for whom four repeated measurements of height and weight were available. Longitudinal analysis of a more extended data set (n = 821), using expected values based on simple linear regression models fitted to the three available sets of measurements of height and weight on the 254 individuals with a missing measurement, also indicates a significant radiation-related growth reduction. The possible contribution of such factors as poor nutrition and disruption of normal family life in the years immediately after the war is difficult to evaluate, but the effects of socioeconomic factors on the analysis of these data are discussed. 33 refs., 5 figs., 3 tabs

  16. PHYSIOLOGICAL RESPONSES AND MOOD STATES AFTER DAILY REPEATED PROLONGED EXERCISE

    Directory of Open Access Journals (Sweden)

    Ilkka Väänänen

    2004-10-01

    Full Text Available The purpose of this study was to describe the physiological responses to daily repeated acute but non-competitive prolonged exercise during a 4-day march and a 2-day cross-country ski event to the cardiorespiratory, autonomic nervous, musculoskeletal and endocrine systems. Mood states were also evaluated after these repeated exercises. The data of these short-term follow-up (reversal field trials was collected from healthy, 23 to 48 year old Finnish male soldiers in 1993 (n=6 and 1994 (n=15 during the "International Four-Day Long-Distance March" in Nijmegen, The Netherlands, and from ten healthy, 22 to 48 year old Finnish male participants in 1995 during a 2-day Finlandia Ski Race in Lahti, Finland. Acute cardiovascular responses were estimated by measuring the heart rate during exercise. The responses of the autonomic nervous system were estimated by measuring the heart rates during the orthostatic test. The musculoskeletal responses were estimated by measuring the perceived pains, flexibility, functional strength, use of elastic energy and oedemic changes of the lower extremities. Hormonal responses were estimated from the urinary excretion of catecholamines, and the concentrations of serum cortisol, testosterone, luteinizing (LH and follicle stimulating hormone (FSH. Mood states were assessed with the Profile of Mood States (POMS questionnaire. Daily walking time was 7-10 hours while the skiing time was 3 hours. Average heart rate during walking was 59% and skiing 87% of maximum heart rate. Morning heart rate in the supine position increased progressively through the marching period but not through the skiing experiment. After the first day, perceived pain increased significantly and remained at a similarly increased level until the end of the exercise period. Leg measurements showed no signs of oedema, decreases in flexibility, or functional strength. Catecholamine excretion rates during marches indicated cumulatively increased

  17. Spatial Cluster Detection for Repeatedly Measured Outcomes while Accounting for Residential History

    OpenAIRE

    Cook, Andrea J.; Gold, Diane R.; Li, Yi

    2009-01-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information ...

  18. Validity and repeatability of goniometry in normal horses.

    Science.gov (United States)

    Adair, Henry S; Marcellin-Little, Denis J; Levine, David

    2016-07-19

    To assess validity and inter- and intra-tester reliability of equine goniometry and to establish values for carpal, metacarpophalangeal, tarsal, and metatarsophalangeal flexion and extension in horses. Seventeen healthy equine subjects of varied breeds were used. Three investigators blindly and independently measured in triplicate the extension and flexion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints of 17 horses after sedation. Radiographs of these joints in flexion and extension were acquired while under sedation. Goniometric and radiographic measurements were compared statistically and were correlated. A Bland-Altman plot was constructed. Inter- and intra-tester repeatability of goniometry were evaluated by calculating intraclass correlation coefficients (ICC). Mean flexion and extension of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints were calculated. Goniometric and radiographic measurements did not differ statistically and were significantly correlated (correlation coefficients ranged from 0.59 - 0.89). The mean difference between goniometric and radiographic measurements was 0.4°. Triplicate measurements collected by the three raters did not differ significantly within raters (ICC ranging from 0.950 - 0.995) and between raters (ICC ranging from 0.942 - 0.989). Goniometry is a valid and repeatable tool for evaluation of the range of motion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints in standing, sedated healthy horses.

  19. Factors associated with repeated outbreak of anthrax in Bangladesh: qualitative and quantitative study

    Directory of Open Access Journals (Sweden)

    Jayedul Hassan

    2015-06-01

    Full Text Available Anthrax, caused by Bacillus anthracis is an acute, febrile disease of warm blooded animals including humans. Social norms and poverty in addition to climatic factors such as soil conditions, seasons of year, ambient temperature and rainfall influence the persistence of the B. anthracis and anthrax outbreaks. The present study was designed to reveal the factors influencing the repeated outbreak of anthrax in Bangladesh. Considering the previous outbreaks of anthrax, Sirajganj, Bogra, Kushtia, Tangail and Mymensingh districts of Bangladesh were selected for this study. To elucidate the factors, qualitative data relating to the animal management, knowledge and behavior of the people; and quantitative data relating to soil conditions, ambient temperature and rainfall were acquired, and analyzed critically. Based on the outbreak histories, a year was divided into two seasons, anthrax prone season (May-November and anthrax dry season (December-April. Anthrax spores could be isolated from 11.67% (n=14/120 of the soil samples collected from the study areas. The present study revealed that poor knowledge, lack of awareness, improper carcass disposal, inadequate vaccination, high Ca content and moisture in the soil along with high ambient temperature and rainfall during the anthrax prone season were the possible influencing factors of repeated outbreaks of anthrax in the study areas. Intensive propaganda to create public awareness of anthrax together with proper vaccination may reduce anthrax outbreaks in Bangladesh.

  20. Test–retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects

    International Nuclear Information System (INIS)

    Cutajar, Marica; Clayden, Jonathan D.; Clark, Christopher A.; Gordon, Isky

    2011-01-01

    Purpose: This study assessed test–retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Materials and methods: Seven healthy volunteers (age range, 19–31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR = 730 ms, TE = 73 ms and 2 b-values (0 and 400 s mm −2 ). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Results: Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Conclusion: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable.

  1. Manual versus automatic bladder wall thickness measurements: a method comparison study

    NARCIS (Netherlands)

    Oelke, M.; Mamoulakis, C.; Ubbink, D.T.; de la Rosette, J.J.; Wijkstra, H.

    2009-01-01

    Purpose To compare repeatability and agreement of conventional ultrasound bladder wall thickness (BWT) measurements with automatically obtained BWT measurements by the BVM 6500 device. Methods Adult patients with lower urinary tract symptoms, urinary incontinence, or postvoid residual urine were

  2. Assessing the repeatability of terrestrial laser scanning for monitoring gully topography: A case study from Aratula, Queensland, Australia

    Science.gov (United States)

    Goodwin, Nicholas Robert; Armston, John; Stiller, Isaac; Muir, Jasmine

    2016-06-01

    Terrestrial laser scanning (TLS) technology is a powerful tool for quantifying gully morphology and monitoring change over time. This is due to the high sampling density, sub-centimetre positional accuracies (x, y, z), flexibility of survey configurations and ability to link multiple TLS scans together. However, to ensure correct interpretation of results, research is needed to test the repeatability of TLS derived products to quantify the accuracy and separate 'false' from 'true' geomorphic change. In this study, we use the RIEGL VZ400 scanner to test the repeatability of TLS datasets for mapping gully morphology. We then quantify change following a rainfall event of approximately 100 mm. Our study site, located in south-east Queensland, Australia was chosen to be challenging from a repeatability perspective with high topographic variability. The TLS data capture involved three sets of linked scans: one survey pre-rainfall, to be compared to two surveys post-rainfall acquired on consecutive days. Change is considered negligible in the two post-rainfall scans to test survey repeatability. To verify TLS accuracy, an independent dataset of gully extent and spot heights were acquired using traditional total station techniques. Results confirm that the TLS datasets can be registered multi-temporally at sub-centimetre levels of accuracy in three dimensions. Total station and TLS elevation samples showed strong agreement with a mean error and standard deviation (SD) of residuals equal to 0.052 and 0.047 m, respectively (n = 889). Significantly, our repeatability tests found that return type and pulse deviation influence the accuracy and repeatability of DEMs in gully environments. Analysis of consecutive day datasets showed that DEMs derived from first return data recorded 40% higher SD of residual error than DEMs using multiple return data. A significant empirical relationship between pulse deviation and the variance of residuals for repeat DEMs is also shown (r2 = 0

  3. Thermal, cardiac and adrenergic responses to repeated local cooling.

    Science.gov (United States)

    Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P

    2006-01-01

    The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.

  4. REPEATABILITY OF FRUIT QUALITY TRAITS OF CACTUS PEAR

    Directory of Open Access Journals (Sweden)

    VALTÂNIA XAVIER NUNES

    2017-12-01

    Full Text Available ABSTRACT Repeatability analysis has been used to study traits in several crops, assisting in the definition of the minimum number needed to evaluate genotypes more efficiently and with less time and resource consumption. So far, however, no repeatability studies on cactus pear have been found in the literature. The objective of this study was to determine the coefficient of repeatability for cactus pear fruits traits and the minimum number of evaluations (fruit that can provide acceptable accuracy for the prediction of the true value. The experiment was conducted at the Federal Institute of Bahia/Campus Guanambi, with 150 fruits collected from three municipalities in the state of Bahia. The coefficients of repeatability were estimated by the methods of analysis of variance, principal components based on the covariance (PCCV and correlation (PCC matrices, and structural analysis based on the correlation matrix (SA. The analysis of variance showed that, except for fruit diameter, the effect of the production site (municipality was significant for all traits evaluated. The PCCV method was proven the most suitable for studying the repeatability of quality traits of cactus pear fruits. Seven fruits were required to determine, with 90% confidence, the traits length, diameter, fruit firmness, skin thickness, number of seeds, fruit mass, bark mass, pulp mass, pH, titratable acidity, soluble solids, SS/AT ratio, and pulp yield.

  5. Cognitive behavioural therapy halves the risk of repeated suicide attempts

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Gøtzsche, Pernille K

    2017-01-01

    is excluded, the risk ratio becomes 0.61 (0.46-0.80) and the heterogeneity in the results disappears (I(2 )= 0%). Conclusions Cognitive behavioural therapy reduces not only repeated self-harm but also repeated suicide attempts. It should be the preferred treatment for all patients with depression.......Objective To study whether cognitive behavioural therapy decreases suicide attempts in people with previous suicide attempts. Design Systematic review and meta-analysis. Setting Randomised trials that compare cognitive behavioural therapy with treatment as usual. Participants Patients who had...... engaged in any type of suicide attempt in the six months prior to trial entry resulting in presentation to clinical services. Main outcome measure Suicide attempt. Results We included ten trials, eight from Cochrane reviews and two from our updated searches (1241 patients, 219 of whom had at least one new...

  6. The Outcome of Repeated Mid Urethral Sling in SUI Treatment after Vaginal Excisions of Primary Failed Sling: Preliminary Study

    Directory of Open Access Journals (Sweden)

    Jacek Kociszewski

    2016-01-01

    Full Text Available Mid urethral sling is the standard in SUI treatment. Nevertheless, the risk of reoperation reaches 9%. There is no consensus as to the best treatment option for complications. A question is raised: what is the optimal way to achieve the best result in patients after primary failure? The aim of the study was to evaluate the outcomes of repeat MUS surgery in patients after excision of the sling with recurrent SUI. We compared its effectiveness with uncomplicated cases treated with TVT. 27 patients who underwent the repeated MUS and 50 consecutive patients after primary TVT were enrolled in the study. After 6 months, we have found that 24 (88.46% patients from repeat sling group and 48 (96% patients after primary sling were dry (1-hour pad test, 2 g or less. The difference between groups was not significant. We showed statistically significant improvement of quality of life in both groups. In conclusion, we showed that repeated sling after MUS excision is almost as effective as primary MUS. We postulate that sling excision and repeated MUS may be the best option for persistent SUI and/or complications after MUS procedures. Further multicenter observations are ongoing as to provide results on bigger group of cases.

  7. CAG repeat polymorphisms in the androgen receptor and breast cancer risk in women: a meta-analysis of 17 studies

    Directory of Open Access Journals (Sweden)

    Mao Q

    2015-08-01

    Full Text Available Qixing Mao,1–3,* Mantang Qiu,1–3,* Gaochao Dong,3 Wenjie Xia,1–3 Shuai Zhang,1,3 Youtao Xu,1,3 Jie Wang,3 Yin Rong,1,3 Lin Xu,1,3 Feng Jiang1,3 1Department of Thoracic Surgery, Nanjing Medical University Affiliated Cancer Institute of Jiangsu Province, 2Fourth Clinical College of Nanjing Medical University, 3Jiangsu Key Laboratory of Molecular and Translational Cancer Research, Nanjing, People’s Republic of China *These authors contributed equally to this work Abstract: The association between polymorphic CAG repeats in the androgen receptor gene in women and breast cancer susceptibility has been studied extensively. However, the conclusions regarding this relationship remain conflicting. The purpose of this meta-analysis was to identify whether androgen receptor CAG repeat lengths were related to breast cancer susceptibility. The MEDLINE, PubMed, and EMBASE databases were searched through to December 2014 to identify eligible studies. Data and study quality were rigorously assessed by two investigators according to the Newcastle-Ottawa Quality Assessment Scale. The publication bias was assessed by the Begg’s test. Seventeen eligible studies were included in this meta-analysis. The overall analysis suggested no association between CAG polymorphisms and breast cancer risk (odds ratio [OR] 1.031, 95% confidence interval [CI] 0.855–1.245. However, in the subgroup analysis, we observed that long CAG repeats significantly increased the risk of breast cancer in the Caucasian population (OR 1.447, 95% CI 1.089–1.992. Additionally, the risk was significantly increased in Caucasian women carrying two alleles with CAG repeats ≥22 units compared with those with two shorter alleles (OR 1.315, 95% CI 1.014–1.707. These findings suggest that long CAG repeats increase the risk of breast cancer in Caucasian women. However, larger scale case-control studies are needed to validate our results. Keywords: androgen, CAG repeat polymorphism, women

  8. SeqEntropy: genome-wide assessment of repeats for short read sequencing.

    Directory of Open Access Journals (Sweden)

    Hsueh-Ting Chu

    Full Text Available BACKGROUND: Recent studies on genome assembly from short-read sequencing data reported the limitation of this technology to reconstruct the entire genome even at very high depth coverage. We investigated the limitation from the perspective of information theory to evaluate the effect of repeats on short-read genome assembly using idealized (error-free reads at different lengths. METHODOLOGY/PRINCIPAL FINDINGS: We define a metric H(k to be the entropy of sequencing reads at a read length k and use the relative loss of entropy ΔH(k to measure the impact of repeats for the reconstruction of whole-genome from sequences of length k. In our experiments, we found that entropy loss correlates well with de-novo assembly coverage of a genome, and a score of ΔH(k>1% indicates a severe loss in genome reconstruction fidelity. The minimal read lengths to achieve ΔH(k<1% are different for various organisms and are independent of the genome size. For example, in order to meet the threshold of ΔH(k<1%, a read length of 60 bp is needed for the sequencing of human genome (3.2 10(9 bp and 320 bp for the sequencing of fruit fly (1.8×10(8 bp. We also calculated the ΔH(k scores for 2725 prokaryotic chromosomes and plasmids at several read lengths. Our results indicate that the levels of repeats in different genomes are diverse and the entropy of sequencing reads provides a measurement for the repeat structures. CONCLUSIONS/SIGNIFICANCE: The proposed entropy-based measurement, which can be calculated in seconds to minutes in most cases, provides a rapid quantitative evaluation on the limitation of idealized short-read genome sequencing. Moreover, the calculation can be parallelized to scale up to large euakryotic genomes. This approach may be useful to tune the sequencing parameters to achieve better genome assemblies when a closely related genome is already available.

  9. The repeatability and reproducibility of the BioRID IIg in a repeatable laboratory seat based on a production car seat.

    Science.gov (United States)

    Hynd, David; Depinet, Paul; Lorenz, Bernd

    2013-01-01

    The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx . However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My . The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was

  10. Oxidative stress adaptation with acute, chronic, and repeated stress.

    Science.gov (United States)

    Pickering, Andrew M; Vojtovich, Lesya; Tower, John; A Davies, Kelvin J

    2013-02-01

    Oxidative stress adaptation, or hormesis, is an important mechanism by which cells and organisms respond to, and cope with, environmental and physiological shifts in the level of oxidative stress. Most studies of oxidative stress adaption have been limited to adaptation induced by acute stress. In contrast, many if not most environmental and physiological stresses are either repeated or chronic. In this study we find that both cultured mammalian cells and the fruit fly Drosophila melanogaster are capable of adapting to chronic or repeated stress by upregulating protective systems, such as their proteasomal proteolytic capacity to remove oxidized proteins. Repeated stress adaptation resulted in significant extension of adaptive responses. Repeated stresses must occur at sufficiently long intervals, however (12-h or more for MEF cells and 7 days or more for flies), for adaptation to be successful, and the levels of both repeated and chronic stress must be lower than is optimal for adaptation to acute stress. Regrettably, regimens of adaptation to both repeated and chronic stress that were successful for short-term survival in Drosophila nevertheless also caused significant reductions in life span for the flies. Thus, although both repeated and chronic stress can be tolerated, they may result in a shorter life. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. How do repeat suicide attempters differ from first timers? An exploratory record based analysis

    Directory of Open Access Journals (Sweden)

    Vikas Menon

    2016-01-01

    Full Text Available Background: Evidence indicates that repeat suicide attempters, as a group, may differ from 1st time attempters. The identification of repeat attempters is a powerful but underutilized clinical variable. Aims: In this research, we aimed to compare individuals with lifetime histories of multiple attempts with 1st time attempters to identify factors predictive of repeat attempts. Setting and Design: This was a retrospective record based study carried out at a teaching cum Tertiary Care Hospital in South India. Methods: Relevant data was extracted from the clinical records of 1st time attempters (n = 362 and repeat attempters (n = 61 presenting to a single Tertiary Care Center over a 4½ year period. They were compared on various sociodemographic and clinical parameters. The clinical measures included Presumptive Stressful Life Events Scale, Beck Hopelessness Scale, Coping Strategies Inventory – Short Form, and the Global Assessment of Functioning Scale. Statistical Analysis Used: First time attempters and repeaters were compared using appropriate inferential statistics. Logistic regression was used to identify independent predictors of repeat attempts. Results: The two groups did not significantly differ on sociodemographic characteristics. Repeat attempters were more likely to have given prior hints about their act (χ2 = 4.500, P = 0.034. In the final regression model, beck hopelessness score emerged as a significant predictor of repeat suicide attempts (odds ratio = 1.064, P = 0.020. Conclusion: Among suicide attempters presenting to the hospital, the presence of hopelessness is a predictor of repeat suicide attempts, independent of clinical depression. This highlights the importance of considering hopelessness in the assessment of suicidality with a view to minimize the risk of future attempts.

  12. simple sequence repeat (SSR)

    African Journals Online (AJOL)

    In the present study, 78 mapped simple sequence repeat (SSR) markers representing 11 linkage groups of adzuki bean were evaluated for transferability to mungbean and related Vigna spp. 41 markers amplified characteristic bands in at least one Vigna species. The transferability percentage across the genotypes ranged ...

  13. A novel magnet based 3D printed marker wand as basis for repeated in-shoe multi segment foot analysis: a proof of concept.

    Science.gov (United States)

    Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin

    2017-01-01

    Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.

  14. Acute effects of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion.

    Science.gov (United States)

    Kobayashi, Ryota; Hashimoto, Yuto; Hatakeyama, Hiroyuki; Okamoto, Takanobu

    2018-03-22

    The aim of this study was to investigate the acute repeated bouts of aerobic exercise decrease leg arterial stiffness. However, the influence of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion is unknown. The present study investigates the acute effects of repeated bouts of aerobic exercise on arterial stiffness after the 75-g oral glucose tolerance test (OGTT). Ten healthy young men (age, 23.2 ± 0.9 years) performed repeated bouts of aerobic exercise trial (RE, 65% peak oxygen uptake; two 15 min bouts of cycling performed 20 min apart) and control trial (CON, seated and resting in a quiet room) at 80 min before the 75-g OGTT on separate days in a randomized, controlled crossover fashion. Carotid-femoral (aortic) and femoral-ankle (leg) pulse wave velocity, carotid augmentation index, brachial and ankle blood pressure, heart rate and blood glucose and insulin levels were measured before (baseline) and 30, 60 and 120 min after the 75-g OGTT. Leg pulse wave velocity, ankle systolic blood pressure and blood glucose levels increased from baseline after the 75-g OGTT in the CON trial, but not in the RE trial. The present findings indicate that acute repeated bouts of aerobic exercise before glucose ingestion suppress increases in leg arterial stiffness following glucose ingestion. RE trial repeated bouts of aerobic exercise trial; CON trial control trial; BG blood glucose; VO 2peak peak oxygen uptake; PWV Pulse wave velocity; AIx carotid augmentation index; BP blood pressure; HR heart rate; CVs coefficients of variation; RPE Ratings of perceived exertion; SE standard error.

  15. Androgen receptor CAG repeat polymorphism and epigenetic influence among the south Indian women with Polycystic Ovary Syndrome.

    Directory of Open Access Journals (Sweden)

    Shilpi Dasgupta

    Full Text Available The present study was carried out to assess the role of androgen receptor CAG repeat polymorphism and X chromosome inactivation (XCI pattern among Indian PCOS women and controls which has not been hitherto explored and also to test the hypothesis that shorter CAG alleles would be preferentially activated in PCOS. CAG repeat polymorphism and X chromosome methylation patterns were compared between PCOS and non-PCOS women. 250 PCOS women and 299 controls were included for this study. Androgen receptor CAG repeat sizes, XCI percentages, and clinical and biochemical parameters were measured. The mean CAG repeat number is similar between the cases (18.74±0.13 and controls (18.73±0.12. The obese PCOS women were significantly more frequent in the 20 CAG repeat category than the lean PCOS women, yielding a highly significant odds (p=0.001. Among the women with non-random X-inactivation, alleles with <19 repeats were more frequently activated among cases than controls (p=0.33. CAG repeat polymorphism by itself cannot be considered as a useful marker for discriminating PCOS. We observed a trend of preferential activation of the shorter allele among the PCOS cases with non random XCI pattern. In the obese PCOS women, this microsatellite variation may account for the hyperandrogenicity to a larger extent than the lean PCOS women.

  16. Performance Comparisons of Improved Regular Repeat Accumulate (RA and Irregular Repeat Accumulate (IRA Turbo Decoding

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulkadhim Hamad

    2017-08-01

    Full Text Available In this paper, different techniques are used to improve the turbo decoding of regular repeat accumulate (RA and irregular repeat accumulate (IRA codes. The adaptive scaling of a-posteriori information produced by Soft-output Viterbi decoder (SOVA is proposed. The encoded pilots are another scheme that applied for short length RA codes. This work also suggests a simple and a fast method to generate a random interleaver having a free 4 cycle Tanner graph. Progressive edge growth algorithm (PEG is also studied and simulated to create the Tanner graphs which have a great girth.

  17. Fourteen Annually Repeated Droughts Suppressed Autotrophic Soil Respiration and Resulted in an Ecosystem Change

    NARCIS (Netherlands)

    Kopittke, G.R.; Tietema, A.; van Loon, E.; Asscheman, D.

    2014-01-01

    Predictions of future climate over the next 100 years show that the frequency of long periods of droughts in summer will increase in the Netherlands. This study investigated the effect of 14 annually repeated droughts on soil respiration at a Dutch heathland. Field measurements of total soil

  18. 78 FR 65594 - Vehicular Repeaters

    Science.gov (United States)

    2013-11-01

    ... coordinators estimate the effect on coordination fees? Does the supposed benefit that mobile repeater stations... allow the licensing and operation of vehicular repeater systems and other mobile repeaters by public... email: [email protected] or phone: 202-418- 0530 or TTY: 202-418-0432. For detailed instructions for...

  19. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  20. Study on the homocysteine metabolism of patients with unexplained repeated spontaneous abortion

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Objective:To study the metabolism abnormality of homocysteine(Hcy) in unexplained repeated spontaneous abortion(URSA).Methods:The level of Hcy in sera was measured with hyperpressure liquid chromatography(HPLC);Folic acid and vitamin B12 were detected by radioimmune assay;anticardiolipin antibody (ACA) was detected by ELISA.Results:(1)The level of serum Hcy in URSA group was significantly higher than that in control group,showing a statistical significant difference(P<0.01).The level of Hcy was correlated with ages,but not correlated with areas,numbers of miscarriage,gestation age,primary or secondary abortions.(2)The levels of folic acid and vitamin B12 in URSA group were significantly lower than those in control group.The levels of serum folic acid and vitamin B12 were not correlated with age,area,numbers of miscarriage and abortion periods.(3)ACA positive rate in URSA was significantly higher than that in control group.The level of Hcy in ACA(+) group was significantly higher than that in ACA(-) group among URSA patients.Conclusions:Hyperhomocysteinemia,low folic acid state,and ACA were all the independent risk factors for URSA.Lacking of folic acid and vitamin B12 is one of the important causes of hyperhomocysteinemia.ACA and hyperhomocysteinemia may have synergistic action in the occurrence of URSA.

  1. Overexpression of MIP2, a novel WD-repeat protein, promotes proliferation of H9c2 cells

    International Nuclear Information System (INIS)

    Wei, Xing; Song, Lan; Jiang, Lei; Wang, Guiliang; Luo, Xinjing; Zhang, Bin; Xiao, Xianzhong

    2010-01-01

    WD40 repeat proteins have a wide range of diverse biological functions including signal transduction, cell cycle regulation, RNA splicing, and transcription. Myocardial ischemic preconditioning up-regulated protein 2 (MIP2) is a novel member of the WD40 repeat proteins superfamily that contains five WD40 repeats. Little is known about its biological role, and the purpose of this study was to determine the role of MIP2 in regulating cellular proliferation. Transfection and constitutive expression of MIP2 in the rat cardiomyoblast cell line H9c2 results in enhanced growth of those cells as measured by cell number and is proportional to the amount of MIP2 expressed. Overexpression of MIP2 results in a shorter cell cycle, as measured by flow cytometry. Collectively, these data suggest that MIP2 may participate in the progression of cell proliferation in H9c2 cells.

  2. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study.

    Science.gov (United States)

    Aten, Jan Jaap; Oudega, Mardien; van Exel, Eric; Stek, Max L; van Waarde, Jeroen A

    2015-06-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment characteristics, clinical outcome, and cognitive functioning after ECT. Thirty-nine unipolar depressed patients dosed using repeated DTM and 40 matched patients treated with ABM were compared. Montgomery-Åsberg Depression Rating Scale (MADRS) and Mini-Mental State Examination (MMSE) were assessed at baseline and at the end of the index course, as well as the total number of ECT sessions. Both groups were similar regarding age, sex, psychotic features, mean baseline MADRS, and median baseline MMSE. At the end of the index course, the two methods showed equal outcome (mean end MADRS, 11.6 ± 8.3 in DTM and 9.5 ± 7.6 in ABM (P = 0.26); median end MMSE, 28 (25-29) and 28 (25-29.8), respectively (P = 0.81). However, the median number of all ECT sessions differed 16 (11-22) in DTM versus 12 (10-14.8) in ABM; P = 0.02]. Using regression analysis, dosing method and age were independently associated with the total number of ECT sessions, with less sessions needed in ABM (P = 0.02) and in older patients (P = 0.001). In this comparative cohort study, ABM and DTM showed equal outcome for depression and cognition. However, the median ECT course duration in repeated DTM appeared longer. Additionally, higher age was associated with shorter ECT courses regardless of the dosing method. Further prospective studies are needed to confirm these findings.

  3. Hearing loss associated with repeated MRI acquisition procedure-related acoustic noise exposure: an occupational cohort study

    NARCIS (Netherlands)

    Bongers, Suzan; Slottje, Pauline; Kromhout, Hans

    2017-01-01

    OBJECTIVE: To study the effects of repeated exposure to MRI-related acoustic noise during image acquisition procedures (scans) on hearing. METHODS: A retrospective occupational cohort study was performed among workers of an MRI manufacturing facility (n=474). Longitudinal audiometry data from the

  4. Primary blast survival and injury risk assessment for repeated blast exposures.

    Science.gov (United States)

    Panzer, Matthew B; Bass, Cameron R Dale; Rafaels, Karin A; Shridharani, Jay; Capehart, Bruce P

    2012-02-01

    The widespread use of explosives by modern insurgents and terrorists has increased the potential frequency of blast exposure in soldiers and civilians. This growing threat highlights the importance of understanding and evaluating blast injury risk and the increase of injury risk from exposure to repeated blast effects. Data from more than 3,250 large animal experiments were collected from studies focusing on the effects of blast exposure. The current study uses 2,349 experiments from the data collection for analysis of the primary blast injury and survival risk for both long- and short-duration blasts, including the effects from repeated exposures. A piecewise linear logistic regression was performed on the data to develop survival and injury risk assessment curves. New injury risk assessment curves uniting long- and short-duration blasts were developed for incident and reflected pressure measures and were used to evaluate the risk of injury based on blast over pressure, positive-phase duration, and the number of repeated exposures. The risk assessments were derived for three levels of injury severity: nonauditory, pulmonary, and fatality. The analysis showed a marked initial decrease in injury tolerance with each subsequent blast exposure. This effect decreases with increasing number of blast exposures. The new injury risk functions showed good agreement with the existing experimental data and provided a simplified model for primary blast injury risk. This model can be used to predict blast injury or fatality risk for single exposure and repeated exposure cases and has application in modern combat scenarios or in setting occupational health limits. .Copyright © 2012 by Lippincott Williams & Wilkins

  5. Repeat Customer Success in Extension

    Science.gov (United States)

    Bess, Melissa M.; Traub, Sarah M.

    2013-01-01

    Four multi-session research-based programs were offered by two Extension specialist in one rural Missouri county. Eleven participants who came to multiple Extension programs could be called "repeat customers." Based on the total number of participants for all four programs, 25% could be deemed as repeat customers. Repeat customers had…

  6. Experimental study on acquisition of knowledge through repeated education and training

    International Nuclear Information System (INIS)

    Sasou, Kunihide; Suzuki, Tomohiro; Yoshimura, Seiichi; Kitamura, Masaharu.

    1997-01-01

    Considering the educational methodology to bring up nuclear power plant operators, the experiments are conducted to discuss the relation between the educational backgrounds of subjects and the knowledge acquired through education and training and also to discuss the effects of repeated training on knowledge acquisition. The results show that the knowledge the subjects obtained through the training depends on their educational backgrounds. The subjects with the higher educational backgrounds seem to properly reorganize the knowledge for the operations with using their deep and meta knowledge. Therefore they can create anticipative responses and easily identify causes of events. The results also show that the repeated education and training given to the subjects with weaker backgrounds makes their knowledge reorganized and their ability becomes closer to the subjects' one with higher educational backgrounds. These results indicate that the knowledge acquired in the earlier stage of the education and training depends on the subjects' educational backgrounds. However, the repeated education and training compensates for the difference. It is also suggested that it will be possible to bring up operators more effectively and properly if the existence of people with different educational backgrounds is recognized and the education/training depending on the educational backgrounds are realized. (author)

  7. Repeat migration and disappointment.

    Science.gov (United States)

    Grant, E K; Vanderkamp, J

    1986-01-01

    This article investigates the determinants of repeat migration among the 44 regions of Canada, using information from a large micro-database which spans the period 1968 to 1971. The explanation of repeat migration probabilities is a difficult task, and this attempt is only partly successful. May of the explanatory variables are not significant, and the overall explanatory power of the equations is not high. In the area of personal characteristics, the variables related to age, sex, and marital status are generally significant and with expected signs. The distance variable has a strongly positive effect on onward move probabilities. Variables related to prior migration experience have an important impact that differs between return and onward probabilities. In particular, the occurrence of prior moves has a striking effect on the probability of onward migration. The variable representing disappointment, or relative success of the initial move, plays a significant role in explaining repeat migration probabilities. The disappointment variable represents the ratio of actural versus expected wage income in the year after the initial move, and its effect on both repeat migration probabilities is always negative and almost always highly significant. The repeat probabilities diminish after a year's stay in the destination region, but disappointment in the most recent year still has a bearing on the delayed repeat probabilities. While the quantitative impact of the disappointment variable is not large, it is difficult to draw comparisons since similar estimates are not available elsewhere.

  8. The absolute number of repeat operations for complex intra ...

    African Journals Online (AJOL)

    abdominal sepsis, questions about futility of treatment frequently arise. This study focuses specifically on patients who required two or more repeat laparotomies and describes the spectrum of disease necessitating multiple repeat laparotomies ...

  9. Repeatability and reproducibility of decisions by latent fingerprint examiners.

    Directory of Open Access Journals (Sweden)

    Bradford T Ulery

    Full Text Available The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as "difficult" than for "easy" or "moderate" comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4; 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization. Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases.

  10. Single molecule study of the intrinsically disordered FG-repeat nucleoporin 153.

    Science.gov (United States)

    Milles, Sigrid; Lemke, Edward A

    2011-10-05

    Nucleoporins (Nups), which are intrinsically disordered, form a selectivity filter inside the nuclear pore complex, taking a central role in the vital nucleocytoplasmic transport mechanism. These Nups display a complex and nonrandom amino-acid architecture of phenylalanine glycine (FG)-repeat clusters and intra-FG linkers. How such heterogeneous sequence composition relates to function and could give rise to a transport mechanism is still unclear. Here we describe a combined chemical biology and single-molecule fluorescence approach to study the large human Nup153 FG-domain. In order to obtain insights into the properties of this domain beyond the average behavior, we probed the end-to-end distance (R(E)) of several ∼50-residues long FG-repeat clusters in the context of the whole protein domain. Despite the sequence heterogeneity of these FG-clusters, we detected a reoccurring and consistent compaction from a relaxed coil behavior under denaturing conditions (R(E)/R(E,RC) = 0.99 ± 0.15 with R(E,RC) corresponding to ideal relaxed coil behavior) to a collapsed state under native conditions (R(E)/R(E,RC) = 0.79 ± 0.09). We then analyzed the properties of this protein on the supramolecular level, and determined that this human FG-domain was in fact able to form a hydrogel with physiological permeability barrier properties. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  11. NIST mixed stain study 3: signal intensity balance in commercial short tandem repeat multiplexes.

    Science.gov (United States)

    Duewer, David L; Kline, Margaret C; Redman, Janette W; Butler, John M

    2004-12-01

    Short-tandem repeat (STR) allelic intensities were collected from more than 60 forensic laboratories for a suite of seven samples as part of the National Institute of Standards and Technology-coordinated 2001 Mixed Stain Study 3 (MSS3). These interlaboratory challenge data illuminate the relative importance of intrinsic and user-determined factors affecting the locus-to-locus balance of signal intensities for currently used STR multiplexes. To varying degrees, seven of the eight commercially produced multiplexes used by MSS3 participants displayed very similar patterns of intensity differences among the different loci probed by the multiplexes for all samples, in the hands of multiple analysts, with a variety of supplies and instruments. These systematic differences reflect intrinsic properties of the individual multiplexes, not user-controllable measurement practices. To the extent that quality systems specify minimum and maximum absolute intensities for data acceptability and data interpretation schema require among-locus balance, these intrinsic intensity differences may decrease the utility of multiplex results and surely increase the cost of analysis.

  12. Measuring Explicit Word Learning of Preschool Children: A Development Study.

    Science.gov (United States)

    Kelley, Elizabeth Spencer

    2017-08-15

    The purpose of this article is to present preliminary results related to the development of a new measure of explicit word learning. The measure incorporated elements of explicit vocabulary instruction and dynamic assessment and was designed to be sensitive to differences in word learning skill and to be feasible for use in clinical settings. The explicit word learning measure included brief teaching trials and repeated fine-grained measurement of semantic knowledge and production of 3 novel words (2 verbs and 1 adjective). Preschool children (N = 23) completed the measure of explicit word learning; standardized, norm-referenced measures of expressive and receptive vocabulary; and an incidental word learning task. The measure of explicit word learning provided meaningful information about word learning. Performance on the explicit measure was related to existing vocabulary knowledge and incidental word learning. Findings from this development study indicate that further examination of the measure of explicit word learning is warranted. The measure may have the potential to identify children who are poor word learners. https://doi.org/10.23641/asha.5170738.

  13. The Study on the Ferrokinetics and Acquired Immunity in Repeated Hookworm Infections

    International Nuclear Information System (INIS)

    Lee, Mun Ho; Lee, Pyl Ung

    1967-01-01

    In order to confirm whether acquired immunity or resistance can be developed by the repeated hookworm infections, the 150 mature actively moving filariform ancylostoma duodenale larvae obtained from the severe hookworm anemia patients were orally given to 8 healthy volunteers in three divided doses, 50 in each, at 5 day interval. Also the hematological changes as well as several ferrokinetics using 59 Fe were done and were compared with 10 controls. The clinical symptoms and signs were checked every day for the first 3 weeks and then twice weekly until the end of the experiment. The appearance of the ova in the stool was examined by the formalin ether method and the ova was counted by the Stoll's method. The following laboratory tests were done:1) Red blood cell count, venous blood hematocrit (micromethod), hemoglobin count (cyanomethemoglobin method) were checked every 5 to 7 day interval. 2) Plasma iron concentration (Barkan's modified method) was determined every 2 to 3 week interval. 3) Radioisotope studies:a) Ferrokinetics: Huff et al and Bothwell's method were applied. Erythropoietic Index (% of normal)= [ S ubject's turnover/100 ml whole bloodX100 ] over [ A verage normal turnover/100 ml whole blood ] b) Quantitative measurement of the gastrointestinal absorption of iron:Radioiron ( 59 Fe) balance method was applied. c) Determination of the plasma erythropoietin activity: Fried's method was applied. Following were the results: 1) The serum iron level was lower. The red cell volume was decreased, but with relative increase of plasma volume. 2) The plasma iron disappearance time was accelerated and the plasma iron turnover rate was decreased. The red cell iron turnover rate was markedly increased, while all of the red cell iron concentration, circulating red cell iron, plasma iron pool were decreased. The daily iron pool turnover and red cell renewal rate were increased. 3) The erythropoietic index, erythropoietin activity and intestinal absorption of iron

  14. The Study on the Ferrokinetics and Acquired Immunity in Repeated Hookworm Infections

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mun Ho; Lee, Pyl Ung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1967-09-15

    In order to confirm whether acquired immunity or resistance can be developed by the repeated hookworm infections, the 150 mature actively moving filariform ancylostoma duodenale larvae obtained from the severe hookworm anemia patients were orally given to 8 healthy volunteers in three divided doses, 50 in each, at 5 day interval. Also the hematological changes as well as several ferrokinetics using {sup 59}Fe were done and were compared with 10 controls. The clinical symptoms and signs were checked every day for the first 3 weeks and then twice weekly until the end of the experiment. The appearance of the ova in the stool was examined by the formalin ether method and the ova was counted by the Stoll's method. The following laboratory tests were done:1) Red blood cell count, venous blood hematocrit (micromethod), hemoglobin count (cyanomethemoglobin method) were checked every 5 to 7 day interval. 2) Plasma iron concentration (Barkan's modified method) was determined every 2 to 3 week interval. 3) Radioisotope studies:a) Ferrokinetics: Huff et al and Bothwell's method were applied. Erythropoietic Index (% of normal)= ['Subject's turnover/100 ml whole bloodX100'] over ['Average normal turnover/100 ml whole blood'] b) Quantitative measurement of the gastrointestinal absorption of iron:Radioiron ({sup 59}Fe) balance method was applied. c) Determination of the plasma erythropoietin activity: Fried's method was applied. Following were the results: 1) The serum iron level was lower. The red cell volume was decreased, but with relative increase of plasma volume. 2) The plasma iron disappearance time was accelerated and the plasma iron turnover rate was decreased. The red cell iron turnover rate was markedly increased, while all of the red cell iron concentration, circulating red cell iron, plasma iron pool were decreased. The daily iron pool turnover and red cell renewal rate were increased. 3) The erythropoietic index, erythropoietin activity and intestinal absorption of

  15. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    Science.gov (United States)

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  16. One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li

    2017-01-01

    This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.

  17. Strategic Interviewing to Detect Deception: Cues to Deception across Repeated Interviews

    Directory of Open Access Journals (Sweden)

    Jaume Masip

    2016-11-01

    Full Text Available Previous deception research on repeated interviews found that liars are not less consistent than truth tellers, presumably because liars use a repeat strategy to be consistent across interviews. The goal of this study was to design an interview procedure to overcome this strategy. Innocent participants (truth tellers and guilty participants (liars had to convince an interviewer that they had performed several innocent activities rather than committing a mock crime. The interview focused on the innocent activities (alibi, contained specific central and peripheral questions, and was repeated after one week without forewarning. Cognitive load was increased by asking participants to reply quickly. The liars’ answers in replying to both central and peripheral questions were significantly less accurate, less consistent, and more evasive than the truth tellers’ answers. Logistic regression analyses yielded classification rates ranging from around 70% (with consistency as the predictor variable, 85% (with evasive answers as the predictor variable, to over 90% (with an improved measure of consistency that incorporated evasive answers as the predictor variable, as well as with response accuracy as the predictor variable. These classification rates were higher than the interviewers’ accuracy rate (54%.

  18. TU-AB-BRA-05: Repeatability of [F-18]-NaF PET Imaging Biomarkers for Bone Lesions: A Multicenter Study

    International Nuclear Information System (INIS)

    Lin, C; Bradshaw, T; Perk, T; Harmon, S; Jeraj, R; Liu, G

    2015-01-01

    Purpose: Quantifying the repeatability of imaging biomarkers is critical for assessing therapeutic response. While therapeutic efficacy has been traditionally quantified by SUV metrics, imaging texture features have shown potential for use as quantitative biomarkers. In this study we evaluated the repeatability of quantitative "1"8F-NaF PET-derived SUV metrics and texture features in bone lesions from patients in a multicenter study. Methods: Twenty-nine metastatic castrate-resistant prostate cancer patients received whole-body test-retest NaF PET/CT scans from one of three harmonized imaging centers. Bone lesions of volume greater than 1.5 cm"3 were identified and automatically segmented using a SUV>15 threshold. From each lesion, 55 NaF PET-derived texture features (including first-order, co-occurrence, grey-level run-length, neighbor gray-level, and neighbor gray-tone difference matrix) were extracted. The test-retest repeatability of each SUV metric and texture feature was assessed with Bland-Altman analysis. Results: A total of 315 bone lesions were evaluated. Of the traditional SUV metrics, the repeatability coefficient (RC) was 12.6 SUV for SUVmax, 2.5 SUV for SUVmean, and 4.3 cm"3 for volume. Their respective intralesion coefficients of variation (COVs) were 12%, 17%, and 6%. Of the texture features, COV was lowest for entropy (0.03%) and highest for kurtosis (105%). Lesion intraclass correlation coefficient (ICC) was lowest for maximum correlation coefficient (ICC=0.848), and highest for entropy (ICC=0.985). Across imaging centers, repeatability of texture features and SUV varied. For example, across imaging centers, COV for SUVmax ranged between 11–23%. Conclusion: Many NaF PET-derived SUV metrics and texture features for bone lesions demonstrated high repeatability, such as SUVmax, entropy, and volume. Several imaging texture features demonstrated poor repeatability, such as SUVtotal and SUVstd. These results can be used to establish response criteria

  19. Impact of a person-centred dementia care training programme on hospital staff attitudes, role efficacy and perceptions of caring for people with dementia: A repeated measures study.

    Science.gov (United States)

    Surr, C A; Smith, S J; Crossland, J; Robins, J

    2016-01-01

    People with dementia occupy up to one quarter of acute hospital beds. However, the quality of care delivered to this patient group is of national concern. Staff working in acute hospitals report lack of knowledge, skills and confidence in caring for people with dementia. There is limited evidence about the most effective approaches to supporting acute hospital staff to deliver more person-centred care. This study aimed to evaluate the efficacy of a specialist training programme for acute hospital staff regarding improving attitudes, satisfaction and feelings of caring efficacy, in provision of care to people with dementia. A repeated measures design, with measures completed immediately prior to commencing training (T1), after completion of Foundation level training (T2: 4-6 weeks post-baseline), and following Intermediate level training (T3: 3-4 months post-baseline). One NHS Trust in the North of England, UK. 40 acute hospital staff working in clinical roles, the majority of whom (90%) were nurses. All participants received the 3.5 day Person-centred Care Training for Acute Hospitals (PCTAH) programme, comprised of two levels, Foundation (0.5 day) and Intermediate (3 days), delivered over a 3-4 months period. Staff demographics and previous exposure to dementia training were collected via a questionnaire. Staff attitudes were measured using the Approaches to Dementia Questionnaire (ADQ), satisfaction in caring for people with dementia was captured using the Staff Experiences of Working with Demented Residents questionnaire (SEWDR) and perceived caring efficacy was measured using the Caring Efficacy Scale (CES). The training programme was effective in producing a significant positive change on all three outcome measures following intermediate training compared to baseline. A significant positive effect was found on the ADQ between baseline and after completion of Foundation level training, but not for either of the other measures. Training acute hospital staff in

  20. Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ahmad, Sumayya; Mathews, Priya M; Lindsley, Kristina; Alkharashi, Majed; Hwang, Frank S; Ng, Sueko M; Aldave, Anthony J; Akpek, Esen Karamursel

    2016-01-01

    To compare repeat penetrating keratoplasty (PK) with Boston type I keratoprosthesis (KPro) implantation for full-thickness donor corneal graft failure. Previous donor graft failure is a common indication for both PK and KPro implantation. Selection of the surgical procedure is entirely dependent on the surgeon because there are no studies available for guidance. Therefore, a systematic review was undertaken to examine vision, device retention, graft clarity, and postoperative glaucoma and infection outcomes after repeat PK versus KPro implantation. Articles with data regarding repeat PK published between 1990 and 2014 were identified in PubMed, EMBASE, the Latin American and Caribbean Health Sciences Literature Database, and the Cochrane Central Register of Controlled Trials and were reviewed. Results were compared with a retrospective review of consecutive, nonrandomized, longitudinal case series of KPro implantations performed at 5 tertiary care centers in the United States. Visual acuity at 2 years was the primary outcome measure. The proportion of clear grafts in the repeat PK group, device retention in the KPro group, and the development of postoperative glaucoma and infection were secondary outcome measures. The search strategy identified 17 128 articles in the PK analysis. After screening, 26 studies (21 case series and 5 cohort studies) were included in the review. Pooled analysis of the 26 unique studies demonstrated a 42% (95% confidence interval [CI], 30%-56%) likelihood of maintaining 20/200 or better at 2 years after repeat PK, compared with an 80% (95% CI, 68%-88%) probability with KPro implantation. The probability of maintaining a clear graft at 5 years was 47% (95% CI, 40%-54%) after repeat PK, whereas the probability of retention of the KPro at 5 years was 75% (95% CI, 64%-84%). The rate of progression of glaucoma at 3 years was 25% (95% CI, 10%-44%) after repeat PK and 30% in the KPro cohort. These results demonstrate favorable outcomes of KPro

  1. A novel method to measure femoral component migration by computed tomography: a cadaver study.

    Science.gov (United States)

    Boettner, Friedrich; Sculco, Peter; Lipman, Joseph; Renner, Lisa; Faschingbauer, Martin

    2016-06-01

    Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.

  2. Studies on Section XI ultrasonic repeatability

    International Nuclear Information System (INIS)

    Jamison, T.D.; McDearman, W.R.

    1981-05-01

    A block representative of a nuclear component has been welded containing intentional defects. Acoustic emission data taken during the welding correlate well with ultrasonic data. Repetitive ultrasonic examinations have been performed by skilled operators using a procedure based on that desribed in ASME Section XI. These examinations were performed by different examination teams using different ultrasonic equipment in such a manner that the effects on the repeatability of the ultrasonic test method caused by the operator and by the use of different equipment could be estimated. It was tentatively concluded that when considering a large number of inspections: (1) there is no significant difference in indication sizing between operators, and (2) there is a significant difference in amplitude and defect sizing when instruments having different, Code acceptable operating characteristics are used. It was determined that the Section XI sizing parameters follow a bivariate normal distribution. Data derived from ultrasonically and physically sizing indications in nuclear components during farication show that the Section XI technique tends to overestimate the size of the reflectors

  3. Repeat Assessed Values Model for Housing Price Index

    Directory of Open Access Journals (Sweden)

    Carini Manuela

    2017-12-01

    Full Text Available This study proposes an innovative methodology, named Repeat Appraised Price Model (RAV, useful for determining the price index numbers for real estate markets and the corresponding index numbers of hedonic prices of main real estate characteristics in the case of a lack of data. The methodological approach proposed in this paper aims to appraise the time series of price index numbers. It integrates the principles of the method of repeat sales with the peculiarities of the Hedonic Price Method, overcoming the problem of an almost total absence of repeat sales for the same property in a given time range; on the other hand, the technique aims to overcome the limitation of the repeat sales technique concerning the inability to take into account the characteristics of individual properties.

  4. Measurement properties of continuous text reading performance tests.

    Science.gov (United States)

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  5. Agreement and repeatability of vascular reactivity estimates based on a breath-hold task and a resting state scan.

    Science.gov (United States)

    Lipp, Ilona; Murphy, Kevin; Caseras, Xavier; Wise, Richard G

    2015-06-01

    FMRI BOLD responses to changes in neural activity are influenced by the reactivity of the vasculature. By complementing a task-related BOLD acquisition with a vascular reactivity measure obtained through breath-holding or hypercapnia, this unwanted variance can be statistically reduced in the BOLD responses of interest. Recently, it has been suggested that vascular reactivity can also be estimated using a resting state scan. This study aimed to compare three breath-hold based analysis approaches (block design, sine-cosine regressor and CO2 regressor) and a resting state approach (CO2 regressor) to measure vascular reactivity. We tested BOLD variance explained by the model and repeatability of the measures. Fifteen healthy participants underwent a breath-hold task and a resting state scan with end-tidal CO2 being recorded during both. Vascular reactivity was defined as CO2-related BOLD percent signal change/mmHg change in CO2. Maps and regional vascular reactivity estimates showed high repeatability when the breath-hold task was used. Repeatability and variance explained by the CO2 trace regressor were lower for the resting state data based approach, which resulted in highly variable measures of vascular reactivity. We conclude that breath-hold based vascular reactivity estimations are more repeatable than resting-based estimates, and that there are limitations with replacing breath-hold scans by resting state scans for vascular reactivity assessment. Copyright © 2015. Published by Elsevier Inc.

  6. Anesthetic efficacy of a repeated intraosseous injection given 30 min following an inferior alveolar nerve block/intraosseous injection.

    OpenAIRE

    Reitz, J.; Reader, A.; Nist, R.; Beck, M.; Meyers, W. J.

    1998-01-01

    To determine whether a repeated intraosseous (IO) injection would increase or prolong pulpal anesthesia, we measured the degree of anesthesia obtained by a repeated IO injection given 30 min following a combination inferior alveolar nerve block/intraosseous injection (IAN/IO) in mandibular second premolars and in first and second molars. Using a repeated-measures design, we randomly assigned 38 subjects to receive two combinations of injections at two separate appointments. The combinations w...

  7. Repeatability of cervical joint flexion and extension within and between days

    DEFF Research Database (Denmark)

    Wang, Xu; Lindstroem, René; Plocharski, Maciej

    2018-01-01

    OBJECTIVE: The purpose of this study was to investigate within- and between-day repeatability of free and unrestricted healthy cervical flexion and extension motion when assessing dynamic cervical spine motion. METHODS: Fluoroscopy videos of 2 repeated cervical flexion and 2 repeated extension...

  8. Analysis of CR1 Repeats in the Zebra Finch Genome

    Directory of Open Access Journals (Sweden)

    George E. Liu

    2013-06-01

    Full Text Available Most bird species have smaller genomes and fewer repeats than mammals. Chicken Repeat 1 (CR1 repeat is one of the most abundant families of repeats, ranging from ~133,000 to ~187,000 copies accounting for ~50 to ~80% of the interspersed repeats in the zebra finch and chicken genomes, respectively. CR1 repeats are believed to have arisen from the retrotransposition of a small number of master elements, which gave rise to multiple CR1 subfamilies in the chicken. In this study, we performed a global assessment of the divergence distributions, phylogenies, and consensus sequences of CR1 repeats in the zebra finch genome. We identified and validated 34 CR1 subfamilies and further analyzed the correlation between these subfamilies. We also discovered 4 novel lineage-specific CR1 subfamilies in the zebra finch when compared to the chicken genome. We built various evolutionary trees of these subfamilies and concluded that CR1 repeats may play an important role in reshaping the structure of bird genomes.

  9. Large Polyglutamine Repeats Cause Muscle Degeneration in SCA17 Mice

    Directory of Open Access Journals (Sweden)

    Shanshan Huang

    2015-10-01

    Full Text Available In polyglutamine (polyQ diseases, large polyQ repeats cause juvenile cases with different symptoms than those of adult-onset patients, who carry smaller expanded polyQ repeats. The mechanisms behind the differential pathology mediated by different polyQ repeat lengths remain unknown. By studying knockin mouse models of spinal cerebellar ataxia-17 (SCA17, we found that a large polyQ (105 glutamines in the TATA-box-binding protein (TBP preferentially causes muscle degeneration and reduces the expression of muscle-specific genes. Direct expression of TBP with different polyQ repeats in mouse muscle revealed that muscle degeneration is mediated only by the large polyQ repeats. Different polyQ repeats differentially alter TBP’s interaction with neuronal and muscle-specific transcription factors. As a result, the large polyQ repeat decreases the association of MyoD with TBP and DNA promoters. Our findings suggest that specific alterations in protein interactions by large polyQ repeats may account for the unique pathology in juvenile polyQ diseases.

  10. Large Polyglutamine Repeats Cause Muscle Degeneration in SCA17 Mice

    Science.gov (United States)

    Huang, Shanshan; Yang, Su; Guo, Jifeng; Yan, Sen; Gaertig, Marta A.; Li, Shihua; Li, Xiao-Jiang

    2015-01-01

    SUMMARY In polyglutamine (polyQ) diseases, large polyQ repeats cause juvenile cases with different symptoms than adult-onset patients, who carry smaller expanded polyQ repeats. The mechanisms behind the differential pathology mediated by different polyQ repeat lengths remain unknown. By studying knock-in mouse models of spinal cerebellar ataxia-17 (SCA17), we found that a large polyQ (105 glutamines) in the TATA box-binding protein (TBP) preferentially causes muscle degeneration and reduces the expression of muscle-specific genes. Direct expression of TBP with different polyQ repeats in mouse muscle revealed that muscle degeneration is mediated only by the large polyQ repeats. Different polyQ repeats differentially alter TBP’s interaction with neuronal and muscle-specific transcription factors. As a result, the large polyQ repeat decreases the association of MyoD with TBP and DNA promoters. Our findings suggest that specific alterations in protein interactions by large polyQ repeats may account for the unique pathology in juvenile polyQ diseases. PMID:26387956

  11. Expression, purification and preliminary biochemical and structural characterization of the leucine rich repeat namesake domain of leucine rich repeat kinase 2.

    Science.gov (United States)

    Vancraenenbroeck, Renée; Lobbestael, Evy; Weeks, Stephen D; Strelkov, Sergei V; Baekelandt, Veerle; Taymans, Jean-Marc; De Maeyer, Marc

    2012-03-01

    Mutations in leucine-rich repeat kinase 2 (LRRK2) are the most common cause of familial Parkinson's disease. Much research effort has been directed towards the catalytic core region of LRRK2 composed of GTPase (ROC, Ras of complex proteins) and kinase domains and a connecting COR (C-terminus of ROC) domain. In contrast, the precise functions of the protein-protein interaction domains, such as the leucine-rich repeat (LRR) domain, are not known. In the present study, we modeled the LRRK2 LRR domain (LRR(LRRK2)) using a template assembly approach, revealing the presence of 14 LRRs. Next, we focused on the expression and purification of LRR(LRRK2) in Escherichia coli. Buffer optimization revealed that the protein requires the presence of a zwitterionic detergent, namely Empigen BB, during solubilization and the subsequent purification and characterization steps. This indicates that the detergent captures the hydrophobic surface patches of LRR(LRRK2) thereby suppressing its aggregation. Circular dichroism (CD) spectroscopy measured 18% α-helices and 21% β-sheets, consistent with predictions from the homology model. Size exclusion chromatography (SEC) and dynamic light scattering measurements showed the presence of a single species, with a Stokes radius corresponding to the model dimensions of a protein monomer. Furthermore, no obvious LRR(LRRK2) multimerization was detected via cross-linking studies. Finally, the LRR(LRRK2) clinical mutations did not influence LRR(LRRK2) secondary, tertiary or quaternary structure as determined via SEC and CD spectroscopy. We therefore conclude that these mutations are likely to affect putative LRR(LRRK2) inter- and intramolecular interactions. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Comparison of step-by-step kinematics in repeated 30m sprints in female soccer players.

    Science.gov (United States)

    van den Tillaar, Roland

    2018-01-04

    The aim of this study was to compare kinematics in repeated 30m sprints in female soccer players. Seventeen subjects performed seven 30m sprints every 30s in one session. Kinematics were measured with an infrared contact mat and laser gun, and running times with an electronic timing device. The main findings were that sprint times increased in the repeated sprint ability test. The main changes in kinematics during the repeated sprint ability test were increased contact time and decreased step frequency, while no change in step length was observed. The step velocity increased in almost each step until the 14, which occurred around 22m. After this, the velocity was stable until the last step, when it decreased. This increase in step velocity was mainly caused by the increased step length and decreased contact times. It was concluded that the fatigue induced in repeated 30m sprints in female soccer players resulted in decreased step frequency and increased contact time. Employing this approach in combination with a laser gun and infrared mat for 30m makes it very easy to analyse running kinematics in repeated sprints in training. This extra information gives the athlete, coach and sports scientist the opportunity to give more detailed feedback and help to target these changes in kinematics better to enhance repeated sprint performance.

  13. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    Science.gov (United States)

    Surgenor, Paul Wg; Freeman, Joan; O'Connor, Cindy

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client's suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook. A quasi-experimental, pre-test post-test repeated measures design was employed. A questionnaire assessing self-esteem, depression, and positive and negative suicidal ideation was administered to the same participants pre- and post- therapy facilitating paired responses. Multiple analysis of variance and paired-samples t-tests were conducted to establish whether therapy using the PH-SIM had a significant effect on the clients' negative and positive outlook. Analyses revealed a statistically significant effect of therapy for depression, negative suicidal ideation, self-esteem, and positive suicidal ideation. Negative outlook was significantly lower after therapy and positive outlook significantly higher. The decreased negative outlook and increased positive outlook following therapy provide some support for the proposed model in fulfilling its role, though additional research is required to establish the precise role of the intervention model in achieving this.

  14. Thickness of the Macula, Retinal Nerve Fiber Layer, and Ganglion Cell Layer in the Epiretinal Membrane: The Repeatability Study of Optical Coherence Tomography.

    Science.gov (United States)

    Lee, Haeng-Jin; Kim, Min-Su; Jo, Young-Joon; Kim, Jung-Yeul

    2015-07-01

    To analyze the repeatability of measurements of the thicknesses of the macula, retinal nerve fiber layer (RNFL), and ganglion cell inner plexiform layer (GCIPL) using spectral-domain optical coherence tomography (SD-OCT) in the epiretinal membrane (ERM). The prospective study analyzed patients who visited our retinal clinic from June 2013 to January 2014. An experienced examiner measured the thicknesses twice using macular cube 512 × 128 and optic disc cube 200 × 200 scans. The repeatability of the thicknesses of the macula, RNFL, and GCIPL were compared using the intraclass correlation coefficient (ICC) of two groups based on the central macular thickness (group A, ≤ 450 μm; group B, > 450 μm). A total of 88 patients were analyzed. The average thicknesses of the central macula, RNFL, and GCIPL were 256.5, 96.6, and 84.4 μm, respectively, in the normal fellow eye and 412.3, 94.6, and 56.7 μm in the affected eye. The ICCs of the central macula, RNFL, and GCIPL were 0.995, 0.994, and 0.996, respectively, for the normal fellow eye and 0.991, 0.973, and 0.881 for the affected eye. The average thicknesses of the central macula, RNFL, and GCIPL in group A were 360.9, 93.5, and 63.4 μm, respectively, and the ICCs were 0.997, 0.987, and 0.995. The thicknesses in group B were 489.5, 96.2, and 46.6 μm, respectively, and the ICCs were 0.910, 0.942, and 0.603, significantly lower repeatability compared with group A (P macula.

  15. Intraspecific variation in flight metabolic rate in the bumblebee Bombus impatiens: repeatability and functional determinants in workers and drones.

    Science.gov (United States)

    Darveau, Charles-A; Billardon, Fannie; Bélanger, Kasandra

    2014-02-15

    The evolution of flight energetics requires that phenotypes be variable, repeatable and heritable. We studied intraspecific variation in flight energetics in order to assess the repeatability of flight metabolic rate and wingbeat frequency, as well as the functional basis of phenotypic variation in workers and drones of the bumblebee species Bombus impatiens. We showed that flight metabolic rate and wingbeat frequency were highly repeatable in workers, even when controlling for body mass variation using residual analysis. We did not detect significant repeatability in drones, but a smaller range of variation might have prevented us from finding significant values in our sample. Based on our results and previous findings, we associated the high repeatability of flight phenotypes in workers to the functional links between body mass, thorax mass, wing size, wingbeat frequency and metabolic rate. Moreover, differences between workers and drones were as predicted from these functional associations, where drones had larger wings for their size, lower wingbeat frequency and lower flight metabolic rate. We also investigated thoracic muscle metabolic phenotypes by measuring the activity of carbohydrate metabolism enzymes, and we found positive correlations between mass-independent metabolic rate and the activity of all enzymes measured, but in workers only. When comparing workers and drones that differ in flight metabolic rate, only the activity of the enzymes hexokinase and trehalase showed the predicted differences. Overall, our study indicates that there should be correlated evolution among physiological phenotypes at multiple levels of organization and morphological traits associated with flight.

  16. Combined Study of Titanium Dioxide Nanoparticle Transport and Toxicity on Microbial Nitrifying Communities under Single and Repeated Exposures in Soil Columns.

    Science.gov (United States)

    Simonin, Marie; Martins, Jean M F; Uzu, Gaëlle; Vince, Erwann; Richaume, Agnès

    2016-10-04

    Soils are exposed to nanoparticles (NPs) as a result of their increasing use in many commercial products. Adverse effects of NPs on soil microorganisms have been reported in several ecotoxicological studies using microcosms. Although repeated exposures are more likely to occur in soils, most of these previous studies were performed as a single exposure to NPs. Contrary to single contamination, the study of multiple NP contaminations in soils requires the use of specialized setups. Using a soil column experiment, we compared the influence of single and repeated exposures (one, two, or three exposures that resulted in the same final concentration applied) on the transport of titanium dioxide (TiO 2 ) NPs through soil and the effect of these different exposure scenarios on the abundance and activity of soil nitrifying microbial communities after a 2 month incubation. The transport of TiO 2 NPs was very limited under both single and repeated exposures and was highest for the lowest concentration injected during the first application. Significant decreases in nitrification activity and ammonia-oxidizing archaea and bacteria populations were observed only for the repeated exposure scenario (three TiO 2 NP contaminations). These results suggest that, under repeated exposures, the transport of TiO 2 NPs to deep soil layers and groundwater is limited and that a chronic contamination is more harmful for the soil microbiological functioning than a single exposure.

  17. Repeated sprint ability in young basketball players: one vs. two changes of direction (Part 2).

    Science.gov (United States)

    Attene, Giuseppe; Laffaye, Guillaume; Chaouachi, Anis; Pizzolato, Fabio; Migliaccio, Gian Mario; Padulo, Johnny

    2015-01-01

    The aim of this study was to compare the training effects based on repeated sprint ability (RSA) (with one change of direction) with an intensive repeated sprint ability (IRSA) (with two changes of direction) on jump performance and aerobic fitness. Eighteen male basketball players were assigned to repeated sprint ability and intensive repeated sprint ability training groups (RSAG and IRSAG). RSA, IRSA, squat jump (SJ), countermovement jump (CMJ) and Yo-Yo intermittent recovery level 1 test were assessed before and after four training weeks. The RSA and IRSA trainings consisted of three sets of six sprints (first two weeks) and eight sprints (second two weeks) with 4-min sets recovery and 20-s of sprints recovery. Four weeks of training led to an overall improvement in most of the measures of RSA, but little evidence of any differences between the two training modes. Jump performance was enhanced: CMJ of 7.5% (P training with one/two changes of direction promotes improvements in both RSA and IRSA respectively but the better increase on jump performance shown a few changes on sprint and endurance performances.

  18. Acute toxicity and the 28-day repeated dose study of a Siddha medicine Nuna Kadugu in rats

    Directory of Open Access Journals (Sweden)

    Ramaswamy Ramaswamy

    2012-10-01

    Full Text Available Abstract Background Nuna Kadugu (NK, a Siddha medicine prepared from leaves and fruits of Morinda Pubescens, used for the treatment of various skin diseases. Though NK has been widely used for several decades, no scientific report was available on its safety. Present study was undertaken to demonstrate the oral toxicity of NK in Sprague Dawley rats. Methods Acute and 28-day repeated oral toxicity studies were performed following OECD test guidelines 423 and 407, respectively, with minor modifications. In acute oral toxicity study, NK was administered at 2000mg/kg b.wt., p.o and animals were observed for toxic signs at 0, 0.5, 1, 4, 24 h and for next 14 days. Gross pathology was performed at the end of the study. In repeated dose, the 28- day oral toxicity study, NK was administered at 300, 600 and 900 mg/kg b.wt./p.o/day. Two satellite groups (control and high dose were also maintained to determine the delayed onset toxicity of NK. Animals were observed for mortality, morbidity, body weight changes, feed and water intake. Haematology, clinical biochemistry, electrolytes, gross pathology, relative organ weight and histopathological examination were performed. Results In acute toxicity study, no treatment related death or toxic signs were observed with NK administration. In the repeated dose study, no significant differences in body weight changes, food / water intake, haematology, clinical biochemistry and electrolytes content were observed between control and NK groups. No gross pathological findings and difference in relative organ weights were observed between control and NK treated rats. Histopathological examination revealed no abnormalities with NK treatment. Conclusion Acute study reveals that the LD50 of NK is greater than 2000mg/kg, b.wt. in fasted female rats and can be classified as Category 5. 28-day repeated oral toxicity demonstrates that the No Observed Adverse Effect Level of NK is greater than 900 mg/kg b.wt./day, p.o in rats

  19. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  20. Structure of thrombospondin type 3 repeats in bacterial outer membrane protein A reveals its intra-repeat disulfide bond-dependent calcium-binding capability

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Shuyan; Sun, Cancan; Tan, Kemin; Ye, Sheng; Zhang, Rongguang

    2017-09-01

    Eukaryotic thrombospondin type 3 repeat (TT3R) is an efficient calcium ion (Ca2+) binding motif only found in mammalian thrombospondin family. TT3R has also been found in prokaryotic cellulase Cel5G, which was thought to forfeit the Ca2+-binding capability due to the formation of intra-repeat disulfide bonds, instead of the inter-repeat ones possessed by eukaryotic TT3Rs. In this study, we have identified an enormous number of prokaryotic TT3R-containing proteins belonging to several different protein families, including outer membrane protein A (OmpA), an important structural protein connecting the outer membrane and the periplasmic peptidoglycan layer in gram-negative bacteria. Here, we report the crystal structure of the periplasmic region of OmpA from Capnocytophaga gingivalis, which contains a linker region comprising five consecutive TT3Rs. The structure of OmpA-TT3R exhibits a well-ordered architecture organized around two tightly-coordinated Ca2+ and confirms the presence of abnormal intra-repeat disulfide bonds. Further mutagenesis studies showed that the Ca2+-binding capability of OmpA-TT3R is indeed dependent on the proper formation of intra-repeat disulfide bonds, which help to fix a conserved glycine residue at its proper position for Ca2+ coordination. Additionally, despite lacking inter repeat disulfide bonds, the interfaces between adjacent OmpA-TT3Rs are enhanced by both hydrophobic and conserved aromatic-proline interactions.

  1. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  2. The Association Between Oxidative Stress and Depressive Symptom Scores in Elderly Population: A Repeated Panel Study

    Directory of Open Access Journals (Sweden)

    Changwoo Han

    2016-09-01

    Full Text Available Objectives Previous epidemiological studies about oxidative stress and depression are limited by hospital-based case-control design, single-time measurements of oxidative stress biomarkers, and the small number of study participants. Therefore, in this study, we analyzed the association between biomarker of oxidative stress and depressive symptom scores using repeatedly measured panel data from a community-dwelling elderly population. Methods From 2008 to 2010, a total of 478 elderly participants residing in Seoul, Korea, were evaluated three times. Participants underwent the Korean version of the Short Form Generic Depression Scale (SGDS-K test for screening depression, and urinary malondialdehyde (MDA levels were measured as an oxidative stress biomarker. We used a generalized estimating equation with a compound symmetry covariance structure to estimate the effects of oxidative stress on depressive symptom scores. Results A two-fold increase in urinary MDA concentration was significantly associated with a 33.88% (95% confidence interval [CI], 21.59% to 47.42% increase in total SGDS-K scores. In subgroup analyses by gender, a two-fold increase in urinary MDA concentration was significantly associated with increased SGDS-K scores in both men and women (men: 30.88%; 95% CI, 10.24% to 55.37%; women: 34.77%; 95% CI, 20.09% to 51.25%. In bivariate analysis after an SGDS-K score ≥8 was defined as depression, the third and the fourth urinary MDA quartiles showed a significantly increased odds ratio(OR of depression compared to the lowest urinary MDA quartile (third quartile OR, 6.51; 95% CI, 1.77 to 24.00; fourth quartile OR, 7.11; 95% CI, 1.99 to 25.42. Conclusions Our study suggests a significant association between oxidative stress and depressive symptoms in the elderly population.

  3. Repeated passive stretching : Acute effect on the passive muscle moment and extensibility of short hamstrings

    NARCIS (Netherlands)

    Halbertsma, JPK; Mulder, [No Value; Goeken, LNH; Eisma, WH; Mulder, I.; Göeken, L.N.

    Objective: To examine the response of short hamstring muscles to repeated passive stretching. Design: A repeated measures design. Setting: A university laboratory for human movement analysis in a department of rehabilitation. Subjects: Students (7 men, 10 women) from the Department of Human Movement

  4. Variable flip angle 3D ultrashort echo time (UTE) T1 mapping of mouse lung: A repeatability assessment.

    Science.gov (United States)

    Alamidi, Daniel F; Smailagic, Amir; Bidar, Abdel W; Parker, Nicole S; Olsson, Marita; Hockings, Paul D; Lagerstrand, Kerstin M; Olsson, Lars E

    2018-03-08

    Lung T 1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T 1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. To evaluate the feasibility of regional lung T 1 quantification with VFA 3D-UTE and to investigate long- and short-term T 1 repeatability in the lungs of naive mice. Prospective preclinical animal study. Eight naive mice and phantoms. 3D free-breathing radial UTE (8 μs) at 4.7T. VFA 3D-UTE T 1 calculations were validated against T 1 values measured with inversion recovery (IR) in phantoms. Lung T 1 and proton density (S 0 ) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T 1 measurements were performed during one of the imaging sessions. Agreement in T 1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson 's correlation analysis. The T 1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Good T 1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T 1 in lung and muscle showed a 5% and 3% CV (1255 ± 63 msec and 1432 ± 42 msec, respectively, mean ± SD) with no changes in T 1 or S 0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T 1 and S 0 . VFA 3D-UTE shows promise as a reliable T 1 mapping method that enables full lung coverage, high signal-to-noise ratio (∼25), and spatial resolution (300 μm) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  5. Unstable systems and repeated measurements. II

    International Nuclear Information System (INIS)

    Exner, P.

    1977-01-01

    Two examples are treated. In the first, the chamber structure is only assumed to be periodic and P(t) is an exponential. In the second example no specific assumption is made about the primary decay law and the measuring device is structured as an idealized spark chamber. This example contains the results by Beskow and Nilsson as a special case. (author)

  6. Study on coal dust wettability measurement using cold briquetting technique

    Energy Technology Data Exchange (ETDEWEB)

    Li, M.; Xu, H.; Shu, X. [North China Institute of Science and Technology, Beijing (China). Department of Resource and Environmental Engineering

    2008-12-15

    Quantitative measuring of coal dust wettability is essential for the research and development of chemical coal dust suppressants in the field of dust control with wetting-agent-added water. The causes of low repeat rate and poor consistency in present lab testing of coal dust wettability are discussed. The influence of different briquetting pressure (from 0 to 6.5108 Pa) on the wet behavior of coal dust is investigated as a new way to quantitatively evaluate coal dust wettability. The study shows that there is a fairly high coincidence between the coal dust wettability data measured by the briquetting technique and the results gained from the lab dust suppression tests using an MCYZ apparatus designed by the authors. 9 refs., 8 figs., 2 tabs.

  7. Huntingtin gene repeat size variations affect risk of lifetime depression.

    Science.gov (United States)

    Gardiner, Sarah L; van Belzen, Martine J; Boogaard, Merel W; van Roon-Mom, Willeke M C; Rozing, Maarten P; van Hemert, Albert M; Smit, Johannes H; Beekman, Aartjan T F; van Grootheest, Gerard; Schoevers, Robert A; Oude Voshaar, Richard C; Roos, Raymund A C; Comijs, Hannie C; Penninx, Brenda W J H; van der Mast, Roos C; Aziz, N Ahmad

    2017-12-11

    Huntington disease (HD) is a severe neuropsychiatric disorder caused by a cytosine-adenine-guanine (CAG) repeat expansion in the HTT gene. Although HD is frequently complicated by depression, it is still unknown to what extent common HTT CAG repeat size variations in the normal range could affect depression risk in the general population. Using binary logistic regression, we assessed the association between HTT CAG repeat size and depression risk in two well-characterized Dutch cohorts─the Netherlands Study of Depression and Anxiety and the Netherlands Study of Depression in Older Persons─including 2165 depressed and 1058 non-depressed persons. In both cohorts, separately as well as combined, there was a significant non-linear association between the risk of lifetime depression and HTT CAG repeat size in which both relatively short and relatively large alleles were associated with an increased risk of depression (β = -0.292 and β = 0.006 for the linear and the quadratic term, respectively; both P < 0.01 after adjustment for the effects of sex, age, and education level). The odds of lifetime depression were lowest in persons with a HTT CAG repeat size of 21 (odds ratio: 0.71, 95% confidence interval: 0.52 to 0.98) compared to the average odds in the total cohort. In conclusion, lifetime depression risk was higher with both relatively short and relatively large HTT CAG repeat sizes in the normal range. Our study provides important proof-of-principle that repeat polymorphisms can act as hitherto unappreciated but complex genetic modifiers of depression.

  8. Topological characteristics of helical repeat proteins

    NARCIS (Netherlands)

    Groves, M R; Barford, D

    The recent elucidation of protein structures based upon repeating amino acid motifs, including the armadillo motif, the HEAT motif and tetratricopeptide repeats, reveals that they belong to the class of helical repeat proteins. These proteins share the common property of being assembled from tandem

  9. Spleen and thymic sonography as estimator of the immune response in children with repeated infections

    International Nuclear Information System (INIS)

    Rabaza, Jesus; Fundora, Hermes; Rodriguez, Alexis; Hernandez, Maria de los Angeles

    2010-01-01

    The spleen is a secondary lymphoid organ. The spleen has many functions: IgM class antibody production and phagocytosis of encapsulated bacteria. We propose to measure the dimensions of the spleen in children with repeated infections, in order to describe them as a diagnosis marker and to explore the probable correlation between the thymic characteristics and the dimensions of the spleen. We study 81 patients that attended the consultation of Immunology from Aballi hospital with repeated infections and they were from 8 months to 9 years old. Children with nutritional value up to the third percentile and those taking steroids 45 days before the study were excluded. We measured the thymic and splenic areas by mediastinal and abdominal echography. The length, the splenic index and the weight are less in patients with repeated infections. These data were significant in 12 to 23 month of age group. The length and the splenic index were less in patients with depletion of thymic area. The sonographic evaluation of the spleen is very important in patients from 1 to 2 years old and in patients with thymic depletion, because they are on the age of vaccine administration according to the Cuban schedule and having affected a main organ for immune response might be a reason for them to show a deficient response and need special schedules

  10. In silico reversal of repeat-induced point mutation (RIP identifies the origins of repeat families and uncovers obscured duplicated genes

    Directory of Open Access Journals (Sweden)

    Hane James K

    2010-11-01

    Full Text Available Abstract Background Repeat-induced point mutation (RIP is a fungal genome defence mechanism guarding against transposon invasion. RIP mutates the sequence of repeated DNA and over time renders the affected regions unrecognisable by similarity search tools such as BLAST. Results DeRIP is a new software tool developed to predict the original sequence of a RIP-mutated region prior to the occurrence of RIP. In this study, we apply deRIP to the genome of the wheat pathogen Stagonospora nodorum SN15 and predict the origin of several previously uncharacterised classes of repetitive DNA. Conclusions Five new classes of transposon repeats and four classes of endogenous gene repeats were identified after deRIP. The deRIP process is a new tool for fungal genomics that facilitates the identification and understanding of the role and origin of fungal repetitive DNA. DeRIP is open-source and is available as part of the RIPCAL suite at http://www.sourceforge.net/projects/ripcal.

  11. Environmental stress induces trinucleotide repeat mutagenesis in human cells.

    Science.gov (United States)

    Chatterjee, Nimrat; Lin, Yunfu; Santillan, Beatriz A; Yotnda, Patricia; Wilson, John H

    2015-03-24

    The dynamic mutability of microsatellite repeats is implicated in the modification of gene function and disease phenotype. Studies of the enhanced instability of long trinucleotide repeats (TNRs)-the cause of multiple human diseases-have revealed a remarkable complexity of mutagenic mechanisms. Here, we show that cold, heat, hypoxic, and oxidative stresses induce mutagenesis of a long CAG repeat tract in human cells. We show that stress-response factors mediate the stress-induced mutagenesis (SIM) of CAG repeats. We show further that SIM of CAG repeats does not involve mismatch repair, nucleotide excision repair, or transcription, processes that are known to promote TNR mutagenesis in other pathways of instability. Instead, we find that these stresses stimulate DNA rereplication, increasing the proportion of cells with >4 C-value (C) DNA content. Knockdown of the replication origin-licensing factor CDT1 eliminates both stress-induced rereplication and CAG repeat mutagenesis. In addition, direct induction of rereplication in the absence of stress also increases the proportion of cells with >4C DNA content and promotes repeat mutagenesis. Thus, environmental stress triggers a unique pathway for TNR mutagenesis that likely is mediated by DNA rereplication. This pathway may impact normal cells as they encounter stresses in their environment or during development or abnormal cells as they evolve metastatic potential.

  12. TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Y; Fuller, C; Mohamed, A; Wang, J; Hazle, J [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients were scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.

  13. Repeatability, number of harvests, and phenotypic stability of dry matter yield and quality traits of Panicum maximum jacq.

    Directory of Open Access Journals (Sweden)

    Francisco Duarte Fernandes

    2017-04-01

    Full Text Available Selection of superior forage genotypes is based on agronomic traits assayed in repeated measures. The questions are how repeatable the performance of individual genotypes is and how many harvests are needed to select the best genotypes. The objectives were to estimate repeatability coefficients of dry matter yield (DMY and forage quality, their phenotypic stability and the number of harvests needed for an accurate selection. Two randomized complete block design experiments data with 24 genotypes each, undergoing 12 and 16 harvests, over a period of 2 and 3 years, respectively, were used. The DMY repeatability estimates ranged from 0.42 to 0.55, suggesting a low heritability. The mean numbers of repeated measures were 5 and 7 harvests for 0.80 and 0.85 accuracy, respectively. The inclusion of the first two harvests negatively affects the estimates. Repeatability for quality traits ranged from 0.30 to 0.69, indicating low to moderate heritability.

  14. Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes

    Science.gov (United States)

    Zavorsky, Gerald S.

    2010-01-01

    Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…

  15. Reject/repeat analysis and the effect prior film viewing has on a department's reject/repeat rate

    International Nuclear Information System (INIS)

    Clark, P.A.; Hogg, P.

    2003-01-01

    Purpose: Achieving cost-effectiveness within the NHS is an old initiative but one that has again been highlighted by recent government policies (The New NHS-Modern and Dependable, Stationary Office, London, 1997). It has been reiterated that it is the responsibility of individual Trusts to devise means to provide such a service. Reject/repeat analyses have long been the primary tool used to assess the cost-effectiveness of radiography departments (Quality Assurance in Diagnostic Radiology, WHO, Geneva, 1982). This research paper examines an in-house initiative (viewing patients' previous films) commonly employed in other Health Trusts in order to reduce departmental repeat/reject rates. Method: Three hundred orthopaedic patients with hip, knee and ankle prostheses were included in a reject/repeat analysis. The aim was to investigate whether or not viewing patient's previous relevant radiographs would be advantageous to the practicing radiographer. This was done through an audit cycle consisting of two audit periods each lasting for 3 months. The primary audit period recorded the baseline repeat/reject rate, with the secondary audit period recording the repeat/reject rate under an experimental condition of viewing the relevant radiographs. Results: The baseline audit revealed repeat rates of 33% in orthopaedic patients with hip, knee and ankle prostheses. The availability of prior film viewing to the radiographer reduced this repeat rate to 10.6%. Conclusion: Prior film viewing dramatically reduced the department's repeat/reject rate by 22.4%. This provides scope for significant patient dose reductions as well as reducing departmental film expenses. This is an underestimated initiative and should be used appropriately in routine clinical practice

  16. Evaluation of the repeated-dose liver micronucleus assay using 2,4-dinitrotoluene: a report of a collaborative study by CSGMT/JEMS.MMS.

    Science.gov (United States)

    Maeda, Akihisa; Tsuchiyama, Hiromi; Asaoka, Yoshiji; Hirakata, Mikito; Miyoshi, Tomoya; Oshida, Keiyu; Miyamoto, Yohei

    2015-03-01

    The liver micronucleus assay using young adult rats has the potential to detect liver carcinogens by repeated dosing, and could be expected to be integrated into repeated-dose toxicity studies using a hepatocyte isolation method without the traditional in situ collagenase perfusion. In this study, to assess the performance of the repeated-dose liver micronucleus assay, 2,4-dinitrotoluene (DNT), which is a rodent liver carcinogen, was administered orally to male rats at doses of 50, 100 and 200 mg/kg/day once daily for 14 or 28 consecutive days, and the frequencies of micronucleated hepatocytes (MNHEPs) and micronucleated immature erythrocytes (MNIMEs) were examined. Significant increases in the MNHEPs were observed at 50 mg/kg/day or more in the 14-day treatment, and 50 and 100 mg/kg/day in the 28-day treatment. These increases were dependent on both the dose and the number of administrations, which indicates the possibility that the MNHEPs accumulate as a result of repeated dosing. In contrast, no increase in the MNIMEs was observed. In conclusion, the repeated-dose liver micronucleus assay using young adult rats is sufficiently sensitive to detect the genotoxicity of 2,4-DNT at a low dose.

  17. Reasons of repeat dental treatment under general anaesthesia: A retrospective study.

    Science.gov (United States)

    Guidry, J; Bagher, S; Felemban, O; Rich, A; Loo, C

    2017-12-01

    The purpose of this chart review study was to investigate the common factors that exist in paediatric patients requiring a repeat dental treatment under general anaesthesia (GA2) within four years after the initial dental treatment under general anaesthesia (GA1). The Electronic Health Records of one to 12 year-old children who received dental treatment under general anaesthesia (GA) between April 2004 and October 2009 were identified and analysed by a single examiner. Children who had GA2, within a four year period following GA1 were categorised as cases. Children who had only one dental treatment under GA were considered the control pool. Each case was matched to three controls based on sex and age range at GA1 of ± 6 months. Other recorded variables included: date of birth, date of GAs (GA1 and GA2 for cases; GA1 for controls), type of payment, dmfs before GA1, dental treatments provided under GA, return of 1-week post-GA1 follow-up, frequency of recare/recall visits following one-year post-GA1 visit and the type and frequency of post GA1 emergency visits. Out of 581 subjects, 29 (4.99%) cases were matched to 87 controls. Medically compromised patients had four times the risk of GA2. At GA1, cases received statistically significant less sealants (p=0.026), less extractions (pdental treatment under general anaesthesia were more likely to have a repeat dental treatment under general anaesthesia within 4 years.

  18. Repeated exposure to conditioned fear stress increases anxiety and delays sleep recovery following exposure to an acute traumatic stressor

    Directory of Open Access Journals (Sweden)

    Benjamin N Greenwood

    2014-10-01

    Full Text Available Repeated stressor exposure can sensitize physiological responses to novel stressors and facilitate the development of stress-related psychiatric disorders including anxiety. Disruptions in diurnal rhythms of sleep-wake behavior accompany stress-related psychiatric disorders and could contribute to their development. Complex stressors that include fear-eliciting stimuli can be a component of repeated stress experienced by humans, but whether exposure to repeated fear can prime the development of anxiety and sleep disturbances is unknown. In the current study, adult male F344 rats were exposed to either control conditions or repeated contextual fear conditioning for 22 days followed by exposure to either no, mild (10, or severe (100 acute uncontrollable tail shock stress. Exposure to acute stress produced anxiety-like behavior as measured by a reduction in juvenile social exploration and exaggerated shock-elicited freezing in a novel context. Prior exposure to repeated fear enhanced anxiety-like behavior as measured by shock-elicited freezing, but did not alter social exploratory behavior. The potentiation of anxiety produced by prior repeated fear was temporary; exaggerated fear was present 1 day but not 4 days following acute stress. Interestingly, exposure to acute stress reduced REM and NREM sleep during the hours immediately following acute stress. This initial reduction in sleep was followed by robust REM rebound and diurnal rhythm flattening of sleep / wake behavior. Prior repeated fear extended the acute stress-induced REM and NREM sleep loss, impaired REM rebound, and prolonged the flattening of the diurnal rhythm of NREM sleep following acute stressor exposure. These data suggest that impaired recovery of sleep / wake behavior following acute stress could contribute to the mechanisms by which a history of prior repeated stress increases vulnerability to subsequent novel stressors and stress-related disorders.

  19. Unusual structures are present in DNA fragments containing super-long Huntingtin CAG repeats.

    Directory of Open Access Journals (Sweden)

    Daniel Duzdevich

    2011-02-01

    Full Text Available In the R6/2 mouse model of Huntington's disease (HD, expansion of the CAG trinucleotide repeat length beyond about 300 repeats induces a novel phenotype associated with a reduction in transcription of the transgene.We analysed the structure of polymerase chain reaction (PCR-generated DNA containing up to 585 CAG repeats using atomic force microscopy (AFM. As the number of CAG repeats increased, an increasing proportion of the DNA molecules exhibited unusual structural features, including convolutions and multiple protrusions. At least some of these features are hairpin loops, as judged by cross-sectional analysis and sensitivity to cleavage by mung bean nuclease. Single-molecule force measurements showed that the convoluted DNA was very resistant to untangling. In vitro replication by PCR was markedly reduced, and TseI restriction enzyme digestion was also hindered by the abnormal DNA structures. However, significantly, the DNA gained sensitivity to cleavage by the Type III restriction-modification enzyme, EcoP15I."Super-long" CAG repeats are found in a number of neurological diseases and may also appear through CAG repeat instability. We suggest that unusual DNA structures associated with super-long CAG repeats decrease transcriptional efficiency in vitro. We also raise the possibility that if these structures occur in vivo, they may play a role in the aetiology of CAG repeat diseases such as HD.

  20. The repeatability of three diagnostic methods (visual using ICDAS II, laser fluorescence, and radiographic) for early caries detection

    Science.gov (United States)

    Sukmasari, S.; Lestari, W.; Ko, B. B.; Noh, Z.; Asmail, N.; Yaacob, N.

    2017-08-01

    Newly introduced ICDAS II as a visual method, laser fluorescence as another technique that have ability to quantify early mineral loss of tooth structure and intra oral radiograph, are methods can be used in the clinic. To provide standardization for comprehensive caries management at an early stage, all methods supposed to be tested between users. The objective of this research is to evaluate the repeatability of each system. It is a comparative cross sectional study using 100 extracted permanent teeth without obvious cavitation (premolar & molar) that were collected and stored in thymol solution. The teeth were embedded on the wax block and labeled with numbers. All 5 surfaces were examined by 5 examiners using visual (ICDAS II), laser fluorescence (LF) and radiographic examination. The data were then analyzed to measure intra and inter examiner repeatability using Cronbach’s alpha and inter-item correlation matrix. Intra-examiner repeatability for all examiners was >0.7. Chronbach’s a value for inter-examiner repeatability for ICDAS II was >0.8 on 3 surfaces except on buccal and lingual. LF exhibit repeatability of >0.8 on all surfaces. Radiograph shows a low value of inter examiner repeatability (students for inter-item correlation while the 2nd and 3rd reading of LF displays the best agreement. ICDAS II score favors more non-invasive treatment compared to LF. ICDAS II showed good repeatability except on buccal and lingual surfaces. In line with some of the previous study, ICDAS II is applicable for caries detection in daily clinical basis. Laser fluorescence exhibits the highest repeatability while the radiograph showed weak inter-examiner repeatability. Treatment decisions of ICDAS II propose more preventive treatment for early caries lesions compared to laser fluorescence.

  1. Repeating Marx

    DEFF Research Database (Denmark)

    Fuchs, Christian; Monticelli, Lara

    2018-01-01

    This introduction sets out the context of the special issue “Karl Marx @ 200: Debating Capitalism & Perspectives for the Future of Radical Theory”, which was published on the occasion of Marx’s bicentenary on 5 May 2018. First, we give a brief overview of contemporary capitalism’s development...... and its crises. Second, we argue that it is important to repeat Marx today. Third, we reflect on lessons learned from 200 years of struggles for alternatives to capitalism. Fourth, we give an overview of the contributions in this special issue. Taken together, the contributions in this special issue show...... that Marx’s theory and politics remain key inspirations for understanding exploitation and domination in 21st-century society and for struggles that aim to overcome these phenomena and establishing a just and fair society. We need to repeat Marx today....

  2. Repeatability and reliability of muscle relaxation properties induced by motor cortical stimulation.

    Science.gov (United States)

    Molenaar, Joery P; Voermans, Nicol C; de Jong, Lysanne A; Stegeman, Dick F; Doorduin, Jonne; van Engelen, Baziel G

    2018-03-15

    Impaired muscle relaxation is a feature of many neuromuscular disorders. However, there are few tests available to quantify muscle relaxation. Transcranial magnetic stimulation (TMS) of the motor cortex can induce muscle relaxation by abruptly inhibiting corticospinal drive. The aim of our study is to investigate if repeatability and reliability of TMS-induced relaxation is greater than voluntary relaxation. Furthermore, effects of sex, cooling and fatigue on muscle relaxation properties were studied. Muscle relaxation of deep finger flexors was assessed in twenty-five healthy subjects (14 M and 11 F, aged 39.1{plus minus}12.7 and 45.3{plus minus}8.7 years old, respectively) using handgrip dynamometry. All outcome measures showed greater repeatability and reliability in TMS-induced relaxation compared to voluntary relaxation. The within-subject coefficient of variability of normalized peak relaxation rate was lower in TMS-induced relaxation than in voluntary relaxation (3.0 vs 19.7% in men, and 6.1 vs 14.3% in women). The repeatability coefficient was lower (1.3 vs 6.1 s -1 in men and 2.3 vs 3.1 s -1 in women), and the intraclass correlation coefficient was higher (0.95 vs 0.53 in men and 0.78 vs 0.69 in women), for TMS-induced relaxation compared to voluntary relaxation. TMS enabled to demonstrate slowing effects of sex, muscle cooling, and muscle fatigue on relaxation properties that voluntary relaxation could not. In conclusion, repeatability and reliability of TMS-induced muscle relaxation was greater compared to voluntary muscle relaxation. TMS-induced muscle relaxation has the potential to be used in clinical practice for diagnostic purposes and therapy effect monitoring in patients with impaired muscle relaxation.

  3. Enhancement of creative expression and entoptic phenomena as after-effects of repeated ayahuasca ceremonies.

    Science.gov (United States)

    Frecska, Ede; Móré, Csaba E; Vargha, András; Luna, Luis E

    2012-01-01

    Studying the effect of psychedelic substances on expression of creativity is a challenging problem. Our primary objective was to study the psychometric measures of creativity after a series of ayahuasca ceremonies at a time when the acute effects have subsided. The secondary objective was to investigate how entoptic phenomena emerge during expression of creativity. Forty individuals who were self-motivated participants of ayahuasca rituals in Brazil completed the visual components of the Torrance Tests of Creative Thinking before and the second day after the end of a two-week long ceremony series. Twenty-one comparison subjects who did not participate in recent psychedelic use also took the Torrance tests twice, two weeks apart. Repeated ingestion of ayahuasca in the ritual setting significantly increased the number of highly original solutions and phosphenic responses. However, participants in the ayahuasca ceremonies exhibited more phosphenic solutions already at the baseline, probably due to the fact that they had more psychedelic experiences within six months prior to the study than the comparison subjects did. This naturalistic study supports the notion that some measures of visual creativity may increase after ritual use of ayahuasca, when the acute psychoactive effects are receded. It also demonstrates an increased entoptic activity after repeated ayahuasca ingestion.

  4. Anthropometric and performance measures to study talent detection in youth volleyball.

    Science.gov (United States)

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia

    2017-12-01

    The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.

  5. Wettability Studies Using Zeta Potential Measurements

    Directory of Open Access Journals (Sweden)

    Ghada Bassioni

    2015-01-01

    Full Text Available Wettability studies have been carried out on reservoir rocks using different techniques such as the Amott-Harvey method, the USBM method, and the contact angle method, all with limitations. In this study, the wettability is studied by discussing the surface charge using zeta potential measurements. The study relies on the finding that carbonated reservoir rocks, consisting of CaCO3 mainly, are positively charged and their surface has the potential to adsorb significant quantities of anions. Moreover, heavy fractions such as asphaltenes are reported to remain afloat depending on dispersive forces present in the oil and its various fractions. Experiments are carried out on aqueous limestone suspension with the addition of crude oil. The experiment is repeated with the use of polymeric inhibitors, A and B. The zeta potential is found to alter depending on the sequence of polymeric inhibitor in oil/water addition. The inhibitor is found to adsorb on the limestone surface, with a net negative charge, causing repulsion between crude oil and the inhibitor and, hence, preventing the deposition of heavy fractions and particularly asphaltenes. This study gives a comprehensive insight on the mechanism of polymeric inhibitor interaction with the surface and the effect of wettability on its performance.

  6. Coordination in continuously repeated games

    NARCIS (Netherlands)

    Weeren, A.J.T.M.; Schumacher, J.M.; Engwerda, J.C.

    1995-01-01

    In this paper we propose a model to describe the effectiveness of coordination in a continuously repeated two-player game. We study how the choice of a decision rule by a coordinator affects the strategic behavior of the players, resulting in more or less cooperation. Our model requires the analysis

  7. Impact of Inclusion or Exclusion of Repeaters on Test Equating

    Science.gov (United States)

    Puhan, Gautam

    2011-01-01

    This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…

  8. Evaluation study of an ion selective field effect transistor electrode for measuring quality parameters of fuel ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Gonzaga, Fabiano B.; Sobral, Sidney P.; Ribeiro, Carla M.; Goncalves, Mary A., E-mail: fbgonzaga@inmetro.gov.br [Instituto Nacional de Metrologia, Qualidade e Tecnologia(INMETRO), Duque de Caxias, RJ (Brazil). Div. de Metrologia Quimica

    2013-01-15

    An ion selective field effect transistor (ISFET) electrode was evaluated for measuring pH and acid number (AN) of fuel ethanol and compared to two glass electrodes with different reference filling solutions: KCl aqueous solution (glass-KCl electrode)and LiCl ethanolic solution (glass-LiCl electrode). pH was determined at different measurement times and AN was determined using automatic potentiometric titration. For pH, the glass-KCl electrode showed the best precision and stability, with an average repeatability about four times better when compared to the ISFET electrode for the measurement time of 30 s (as indicated in the ASTM D6423 standard). For AN, the glass-KCl and glass-LiCl electrodes showed similar repeatabilities, which were about three times better than that of the ISFET electrode. In addition, the results from a recovery study demonstrated better accuracy of the glass-LiCl electrode, with a recovery value of 100.1% (author)

  9. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  10. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans

    Science.gov (United States)

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-07-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature ( P cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  11. Carbohydrate mouth rinse does not improve repeated sprint performance

    Directory of Open Access Journals (Sweden)

    Leandro Ricardo Altimari

    2013-09-01

    Full Text Available The objective of this study was to evaluate the effect of a carbohydrate mouth rinse on the repeated sprint ability (RSA of young soccer players. Nine youth soccer players (15.0 ± 1.5 years; 60.7 ± 4.84 kg; 1.72 ± 0.05 m; 20.5 ± 1.25 kg/m2 were selected. The athletes were submitted to an RSA test consisting of six sprints of 40 m (going/return = 20 m + 20 m, separated by 20 s of passive recovery, under three experimental conditions: carbohydrate mouth rinse (CHO or placebo (PLA and control (CON. The mouth rinses containing CHO or PLA were administered 5 min and immediately before the beginning of the test in doses of 100 mL. The best sprint time (RSAbest, mean sprint time (RSAmean, and drop-off in sprint performance (fatigue index were determined for the different treatments. One-not identify significant differences (p> 0.05 in RSAbest (CHO way ANOVA for repeated measures did = 7.30 ± 0.31 s; PLA = 7.30 ± 0.30 s; CON = 7.26 ±0.16 s, RSA mean (CHO = 7.71 ± 0.30 s; PLA = 7.71 ± 0.25 s; CON = 7.66 ± 0.24s, or fatigue index (CHO = 5.58 ± 2.16%; PLA = 5.77 ± 3.04%; CON = 5.55 ±3.72%. The results suggest that a carbohydrate mouth rinse does not improve the repeated sprint performance of young soccer players.

  12. Fixed or adapted conditioning intensity for repeated conditioned pain modulation.

    Science.gov (United States)

    Hoegh, M; Petersen, K K; Graven-Nielsen, T

    2017-12-29

    Aims Conditioned pain modulation (CPM) is used to assess descending pain modulation through a test stimulation (TS) and a conditioning stimulation (CS). Due to potential carry-over effects, sequential CPM paradigms might alter the intensity of the CS, which potentially can alter the CPM-effect. This study aimed to investigate the difference between a fixed and adaptive CS intensity on CPM-effect. Methods On the dominant leg of 20 healthy subjects the cuff pressure detection threshold (PDT) was recorded as TS and the pain tolerance threshold (PTT) was assessed on the non-dominant leg for estimating the CS. The difference in PDT before and during CS defined the CPM-effect. The CPM-effect was assessed four times using a CS with intensities of 70% of baseline PTT (fixed) or 70% of PTT measured throughout the session (adaptive). Pain intensity of the conditioning stimulus was assessed on a numeric rating scale (NRS). Data were analyzed with repeated-measures ANOVA. Results No difference was found comparing the four PDTs assessed before CSs for the fixed and the adaptive paradigms. The CS pressure intensity for the adaptive paradigm was increasing during the four repeated assessments (P CPM-effect was higher using the fixed condition compared with the adaptive condition (P CPM paradigms using a fixed conditioning stimulus produced an increased CPM-effect compared with adaptive and increasing conditioning intensities.

  13. Collaborative work on evaluation of ovarian toxicity. 13) Two- or four-week repeated dose studies and fertility study of PPAR alpha/gamma dual agonist in female rats.

    Science.gov (United States)

    Sato, Norihiro; Uchida, Keisuke; Nakajima, Mikio; Watanabe, Atsushi; Kohira, Terutomo

    2009-01-01

    The main focus of this study was to determine the optimal dosing period in a repeated dose toxicity study based on toxic effects as assessed by ovarian morphological changes. To assess morphological and functional changes induced in the ovary by a peroxisome proliferator-activated receptor (PPAR) alpha/gamma dual agonist, the compound was administered to female rats at dose levels of 0, 4, 20, and 100 mg/kg/day in a repeated dose toxicity study for 2 or 4 weeks, and from 2 weeks prior to mating to Day 7 of pregnancy in a female fertility study. In the repeated dose toxicity study, an increase in atresia of large follicles, a decrease in corpora lutea, and an increase in stromal cells were observed in the treated groups. In addition, the granulosa cell exfoliations into antrum of large follicles and corpora lutea with retained oocyte are morphological characteristics induced by this compound, and they might be related with abnormal condition of ovulation. In the female fertility study, the pregnancy rate tended to decrease in the 100 mg/kg/day group. At necropsy, decreases in the number of corpora lutea, implantations and live embryos were noted in the 20 and 100 mg/kg/day group. No changes were observed in animals given 4 mg/kg/day. These findings indicated that histopathological changes in the ovary are important endpoints for evaluation of drugs inducing ovarian damage. In conclusion, a 2-week administration period is sufficient to detect ovarian toxicity of this test compound in the repeated dose toxicity study.

  14. Perfectionism and negative affect after repeated failure: Anxiety, depression, and anger

    OpenAIRE

    Stoeber, Joachim; Schneider, Natalia; Hussain, Rimi; Matthews, Kelly

    2014-01-01

    Perfectionists have shown increased negative affect after failure compared to nonperfectionists. However, little is known about how perfectionists react to repeated failure. This study investigated the effects of two forms of perfectionism--self-oriented perfectionism and socially prescribed perfectionism--on 100 university students’ reactions to repeated failure (versus repeated success) examining three negative emotions: anxiety, depression, and anger. Results showed that socially prescribe...

  15. Knowledge and Skill Retention of In-Service versus Preservice Nursing Professionals following an Informal Training Program in Pediatric Cardiopulmonary Resuscitation: A Repeated-Measures Quasiexperimental Study

    Directory of Open Access Journals (Sweden)

    Jhuma Sankar

    2013-01-01

    Full Text Available Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses and final year undergraduate nursing students (preservice nurses using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants—28 in-service and 46 preservice professionals—were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P=0.08 while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P<0.001. Immediately after training, the scores improved in both groups. At 6 weeks however, we observed a nonuniform decline in performance in both groups—in-service nurses performing better in knowledge test (10.5 versus 9.1, P=0.01 and the preservice nurses performing better in skill test (9.8 versus 7.4, P<0.001. Thus, knowledge and skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  16. In Vivo and in Vitro Evaluations of Repeatability and Accuracy of VITA Easyshade® Advance 4.0 Dental Shade-Matching Device

    Directory of Open Access Journals (Sweden)

    Davor Illeš

    2015-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the intra-device repeatability and accuracy of dental shade-matching device (VITA Easyshade® Advance 4.0 using both in vitro and in vivo models. Materials and methods: For the repeatability assessment, the in vivo model utilized shade-matching device to measure the central region of the labial surface of right maxillary central incisors of 10 people twice. The following tooth colors were measured: B1, A1, A2, A3, C1 and C3. The in vitro model included the same six Vitapan Classical tabs. Two measurements were made of the central region of each shade tab. For the accuracy assessment, each shade tab from 3 Vitapan Classical shade guides was measured once. CIE L*a*b* values were determined. Intraclass correlation coefficients (ICCs were used to analyze the in vitro and in vivo intra-device repeatability of the shade-matching device. The difference between in vitro and in vivo models was analyzed. Accuracy of the device tested was calculated. Results: The mean color differences for in vivo and in vitro models were 3.51 and 1.25 E units, respectively. The device repeatability ICCs for in vivo measurements ranged from 0.858 to 0.971 and for in vitro from 0.992 to 0.994. Accuracy of the device tested was 93.75%. Conclusion: Within the limitations of the experiment, VITA Easyshade®Advance 4.0 dental shade-matching device enabled reliable and accurate measurement. It can be a valuable tool for the determination of tooth colours.

  17. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    OpenAIRE

    Van Gucht, Dinska; Vansteenwegen, Debora; Beckers, Tom; Hermans, Dirk; Baeyens, Frank; Van den Bergh, Omer

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n=40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days. Control participants (n=18) received two exposures at the start and end of each session. Chocolate craving was measured (alternately) through subjective report and the amount of saliva secretion to cho...

  18. Visual assessment of the cervical vertebral maturation stages: A study of diagnostic accuracy and repeatability.

    Science.gov (United States)

    Perinetti, Giuseppe; Caprioglio, Alberto; Contardo, Luca

    2014-11-01

    To evaluate the diagnostic accuracy and repeatability of the visual assessment of the cervical vertebral maturation (CVM) stages. Ten operators underwent training sessions in visual assessment of CVM staging. Subsequently, they were asked to stage 72 cases equally divided into the six stages. Such assessment was repeated twice in two sessions (T1 and T2) 4 weeks apart. A reference standard for each case was created according to a cephalometric analysis of both the concavities and shapes of the cervical vertebrae. The overall agreement with the reference standard was about 68% for both sessions and 76.9% for intrarater repeatability. The overall kappa coefficients with the reference standard were up to 0.86 for both sessions, and 0.88 for intrarater repeatability. Overall, disagreements one stage and twp stage apart were 23.5% (T1) and 5.1% (T2), respectively. Sensitivity ranged from 53.3% for CS5 (T1) to 99.9% for CS1 (T2), positive predictive values ranged from 52.4% for CS5 (T2) to 94.3% for CS6 (T1), and accuracy ranged from 83.6% for CS4 (T2) to 94.9% for CS1 (T1). Visual assessment of the CVM stages is accurate and repeatable to a satisfactory level. About one in three cases remain misclassified; disagreement is generally limited to one stage and is mostly seen in stages 4 and 5.

  19. Autocorrelation and cross-correlation between hCGβ and PAPP-A in repeated sampling during first trimester of pregnancy

    DEFF Research Database (Denmark)

    Nørgaard, Pernille; Wright, Dave; Ball, Susan

    2013-01-01

    Theoretically, repeated sampling of free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein-A (PAPP-A) in the first trimester of pregnancy might improve performance of risk assessment of trisomy 21 (T21). To assess the performance of a screening test involving repeated...... measures of biochemical markers, correlations between markers must be estimated. The aims of this study were to calculate the autocorrelation and cross-correlation between hCGβ and PAPP-A in the first trimester of pregnancy and to investigate the possible impact of gestational age at the first sample...

  20. A comparative study on pathological features of transgenic rat lines expressing either three or four repeat misfolded tau.

    Science.gov (United States)

    Valachova, Bernadeta; Brezovakova, Veronika; Bugos, Ondrej; Jadhav, Santosh; Smolek, Tomas; Novak, Petr; Zilka, Norbert

    2018-08-01

    Human tauopathies represent a heterogeneous group of neurodegenerative disorders characterized by distinct clinical features, typical histopathological structures, and defined ratio(s) of three-repeat and four-repeat tau isoforms within pathological aggregates. How the optional microtubule-binding repeat of tau influences this differentiation of pathologies is understudied. We have previously generated and characterized transgenic rodent models expressing human truncated tau aa151-391 with either three (SHR24) or four microtubule-binding repeats (SHR72). Here, we compare the behavioral and neuropathological hallmarks of these two transgenic lines using a battery of tests for sensorimotor, cognitive, and neurological functions over the age range of 3.5-15 months. Progression of sensorimotor and neurological deficits was similar in both transgenic lines; however, the lifespan of transgenic line SHR72 expressing truncated four-repeat tau was markedly shorter than SHR24. Moreover, the expression of three or four-repeat tau induced distinct neurofibrillary pathology in these lines. Transgenic lines displayed different distribution of tau pathology and different type of neurofibrillary tangles. Our results suggest that three- and four-repeat isoforms of tau may display different modes of action in the diseased brain. © 2018 Wiley Periodicals, Inc.

  1. Electromyographic analysis of repeated bouts of eccentric exercise.

    Science.gov (United States)

    McHugh, M P; Connolly, D A; Eston, R G; Gartman, E J; Gleim, G W

    2001-03-01

    The repeated bout effect refers to the protective effect provided by a single bout of eccentric exercise against muscle damage from a similar subsequent bout. The aim of this study was to determine if the repeated bout was associated with an increase in motor unit activation relative to force production, an increased recruitment of slow-twitch motor units or increased motor unit synchronization. Surface electromyographic (EMG) signals were recorded from the hamstring muscles during two bouts of submaximal isokinetic (2.6 rad x s(-1)) eccentric (11 men, 9 women) or concentric (6 men, 4 women) contractions separated by 2 weeks. The EMG per unit torque and median frequency were analysed. The initial bout of eccentric exercise resulted in strength loss, pain and muscle tenderness, while the repeated eccentric bout resulted in a slight increase in strength, no pain and no muscle tenderness (bout x time effects, P exercise. The EMG per unit torque and median frequency were not different between the initial and repeated bouts of eccentric exercise. The EMG per unit torque and median frequency increased during both bouts of eccentric exercise (P < 0.01) but did not change during either concentric bout. In conclusion, there was no evidence that the repeated bout effect was due to a neural adaptation.

  2. Repeated radiation injuries by fission products

    International Nuclear Information System (INIS)

    Vasilenko, I.Ya.

    1986-01-01

    Attention is given to repeated radiation injuries during internal irradiation of theoretical and practical interest, particularly in case of the intake into organism of young products of nuclear fission (PNF). The results of experiments with dogs with repeated radioactive iodine injury the isotopes of which (131-135sub(I)) constitute a considerable part of PNF activity are discussed. The blood reaction and protein metabolism state have been studied. Observations for dogs have been continued for about 4 years. The doses for thyroid, gastrointestinal tract and liver subjected to the most intensive irradiation consituted in the first series of experiments after the first intake about 3;0.3;0.05 Gy, after the second - 5;0.5;0.08 Gy and in the second series of experiments - 3;0.3;0.05 Gy and 0.6;0.06;0.01 Gy, respectively. Hematologic factors,thyroid function, changes in exchange and immunologic reactivity have been studied. The dogs have been under observation for 5 years. It is shown in case of repeated intake of Isup(131) PNF into animals organism in quantity which does not cause during the acute period a clinically outlined sickness, substantial differences in the organism reaction as compared with the first intake of radionuclides have not been found. The presence of residual radiation injuries did not cause charging action during the acute period during PNF and repeated intake which in the author's opinion testifies to perfection of compensator mechanisms in case of intake of such quantities of radioactive products. At the remote periods blastomogenic action manifested which is estimated as a result of general biological action of radionuclides administered to the organism. The necessity in subsequent investigations for obtaining the data on organism reactivity, clinic and pathogenesis with the aim of prophylaxis and treatment of such injuries is indicated

  3. Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data

    Science.gov (United States)

    Bao, FangJun; Wang, JunJie; Huang, JinHai; Yu, Ye; Deng, ManLi; Li, LinNa; Yu, AYong; Wang, QinMei; Davey, Pinakin Gunvant; Elsheikh, Ahmed

    2015-01-01

    Purpose To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data. Methods Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm. The method simultaneously considered the anterior and posterior maps taken for the same eye since they were assumed to have the same set of misalignment components. A new parameter, named Combined Misalignment parameter (CM), has been developed to combine the effect of all six misalignment components on topography data and so enable study of the association between misalignment and the data repeatability test results. Results The repeatability tests resulted in average root mean square (RMS) differences in elevation data of 8.46±2.75 μm before ICP map matching when simultaneously considering anterior and posterior surfaces. With map matching and misalignment correction, the differences decreased to 7.28±2.58 μm (P = 0.00). When applied to only the anterior maps, misalignment correction led to a more pronounced reduction in elevation data differences from 4.58±1.84 μm to 2.97±1.29 μm (P = 0.00). CM was found to be associated with the repeatability error (P = 0.00), with posterior maps being responsible for most of the error due to their relatively lower accuracy compared to anterior maps

  4. Mechanism of Repeat-Associated MicroRNAs in Fragile X Syndrome

    Directory of Open Access Journals (Sweden)

    Karen Kelley

    2012-01-01

    Full Text Available The majority of the human genome is comprised of non-coding DNA, which frequently contains redundant microsatellite-like trinucleotide repeats. Many of these trinucleotide repeats are involved in triplet repeat expansion diseases (TREDs such as fragile X syndrome (FXS. After transcription, the trinucleotide repeats can fold into RNA hairpins and are further processed by Dicer endoribonuclases to form microRNA (miRNA-like molecules that are capable of triggering targeted gene-silencing effects in the TREDs. However, the function of these repeat-associated miRNAs (ramRNAs is unclear. To solve this question, we identified the first native ramRNA in FXS and successfully developed a transgenic zebrafish model for studying its function. Our studies showed that ramRNA-induced DNA methylation of the FMR1 5′-UTR CGG trinucleotide repeat expansion is responsible for both pathological and neurocognitive characteristics linked to the transcriptional FMR1 gene inactivation and the deficiency of its protein product FMRP. FMRP deficiency often causes synapse deformity in the neurons essential for cognition and memory activities, while FMR1 inactivation augments metabotropic glutamate receptor (mGluR-activated long-term depression (LTD, leading to abnormal neuronal responses in FXS. Using this novel animal model, we may further dissect the etiological mechanisms of TREDs, with the hope of providing insights into new means for therapeutic intervention.

  5. Use of short tandem repeat sequences to study Mycobacterium leprae in leprosy patients in Malawi and India.

    Directory of Open Access Journals (Sweden)

    Saroj K Young

    2008-04-01

    Full Text Available Inadequate understanding of the transmission of Mycobacterium leprae makes it difficult to predict the impact of leprosy control interventions. Genotypic tests that allow tracking of individual bacterial strains would strengthen epidemiological studies and contribute to our understanding of the disease.Genotyping assays based on variation in the copy number of short tandem repeat sequences were applied to biopsies collected in population-based epidemiological studies of leprosy in northern Malawi, and from members of multi-case households in Hyderabad, India. In the Malawi series, considerable genotypic variability was observed between patients, and also within patients, when isolates were collected at different times or from different tissues. Less within-patient variability was observed when isolates were collected from similar tissues at the same time. Less genotypic variability was noted amongst the closely related Indian patients than in the Malawi series.Lineages of M. leprae undergo changes in their pattern of short tandem repeat sequences over time. Genetic divergence is particularly likely between bacilli inhabiting different (e.g., skin and nerve tissues. Such variability makes short tandem repeat sequences unsuitable as a general tool for population-based strain typing of M. leprae, or for distinguishing relapse from reinfection. Careful use of these markers may provide insights into the development of disease within individuals and for tracking of short transmission chains.

  6. On repeated corneal applanation with the Goldmann and two non-contact tonometers.

    Science.gov (United States)

    Almubrad, Turki M; Ogbuehi, Kelechi C

    2010-03-01

    Several authors believe it is necessary to randomise the order in which contact and non-contact tonometers are used in comparison studies. This study was carried out to investigate the effect of repeated applanation on the measured intraocular pressure. One set of measurements per session was made on each of three sessions (one session per day) with the Goldmann and two non-contact tonometers (Topcon CT80 and Keeler Pulsair EasyEye), in a pre-determined order, on one randomly selected eye of 120 subjects randomised to one of two groups. For session one, only the non-contact tonometers were used to assess the intraocular pressure of both groups. For session two, either non-contact or Goldmann tonometry was performed first and this order was reversed for session 3. Average intraocular pressures were compared between sessions to determine the presence or absence of effects on the intraocular pressure caused by prior repeated applanation with the Goldmann or either one (or both) of the non-contact tonometers. Prior applanation with a non-contact tonometer did not cause a significant (p > 0.05) reduction of the mean pressure measured with either non-contact tonometer. The mean pressure was slightly but significantly (p contact tonometers in both subject groups) when non-contact tonometry was performed after Goldmann tonometry. There was no significant difference (p > 0.05) between the pressures measured with the Goldmann tonometer prior to and subsequent to non-contact tonometry, in both subject groups. A small but statistically significant reduction in the intraocular pressure was found following applanation with the Goldmann tonometer but not with either one of two non-contact tonometers.

  7. A repeat-until-success quantum computing scheme

    Energy Technology Data Exchange (ETDEWEB)

    Beige, A [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom); Lim, Y L [DSO National Laboratories, 20 Science Park Drive, Singapore 118230, Singapore (Singapore); Kwek, L C [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542, Singapore (Singapore)

    2007-06-15

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes.

  8. A repeat-until-success quantum computing scheme

    International Nuclear Information System (INIS)

    Beige, A; Lim, Y L; Kwek, L C

    2007-01-01

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes

  9. Readout Distance Enhancement of the Passive Wireless Multi-Parameter Sensing System Using a Repeater Coil

    Directory of Open Access Journals (Sweden)

    Lifeng Wang

    2018-01-01

    Full Text Available A repeater coil is used to extend the detection distance of a passive wireless multi-parameter sensing system. The passive wireless sensing system has the ability of simultaneously monitoring three parameters by using backscatter modulation together with channel multiplexing. Two different repeater coils are designed and fabricated for readout distance enhancement of the sensing system: one is a PCB (printed circuit board repeater coil, and the other is a copper wire repeater coil. Under the conditions of fixed voltage and adjustable voltage, the maximum readout distance of the sensing system with and without a repeater coil is measured. Experimental results show that larger power supply voltage can help further increase the readout distance. The maximum readout distance of the sensing system with a PCB repeater coil has been extended 2.3 times, and the one with a copper wire repeater coil has been extended 3 times. Theoretical analysis and experimental results both indicate that the high Q factor repeater coil can extend the readout distance more. With the copper wire repeater coil as well as a higher power supply voltage, the passive wireless multi-parameter sensing system finally achieves a maximum readout distance of 13.5 cm.

  10. Effect of repeated compaction of tablets on tablet properties and work of compaction using an instrumented laboratory tablet press.

    Science.gov (United States)

    Gamlen, Michael John Desmond; Martini, Luigi G; Al Obaidy, Kais G

    2015-01-01

    The repeated compaction of Avicel PH101, dicalcium phosphate dihydrate (DCP) powder, 50:50 DCP/Avicel PH101 and Starch 1500 was studied using an instrumented laboratory tablet press which measures upper punch force, punch displacement and ejection force and operates using a V-shaped compression profile. The measurement of work compaction was demonstrated, and the test materials were ranked in order of compaction behaviour Avicel PH101 > DCP/Avicel PH101 > Starch > DCP. The behaviour of the DCP/Avicel PH101 mixture was distinctly non-linear compared with the pure components. Repeated compaction and precompression had no effect on the tensile fracture strength of Avicel PH101 tablets, although small effects on friability and disintegration time were seen. Repeated compaction and precompression reduced the tensile strength and the increased disintegration time of the DCP tablets, but improved the strength and friability of Starch 1500 tablets. Based on the data reported, routine laboratory measurement of tablet work of compaction may have potential as a critical quality attribute of a powder blend for compression. The instrumented press was suitable for student use with minimal supervisor input.

  11. To be so bold: boldness is repeatable and related to within individual behavioural variability in North Island robins.

    Science.gov (United States)

    He, Ruchuan; Pagani-Núñez, Emilio; Chevallier, Clément; Barnett, Craig R A

    2017-07-01

    Behavioural research traditionally focusses on the mean responses of a group of individuals rather than variation in behaviour around the mean or among individuals. However, examining the variation in behaviour among and within individuals may also yield important insights into the evolution and maintenance of behaviour. Repeatability is the most commonly used measure of variability among individuals in behavioural research. However, there are other forms of variation within populations that have received less attention. One such measure is intraindividual variation in behaviour (IIV), which is a short-term fluctuation of within-individual behaviour. Such variation in behaviour might be important during interactions because it could decrease the ability of conspecific and heterospecific individuals to predict the behaviour of the subject, thus increasing the cost of the interaction. In this experiment, we made repeated measures of the latency of North Island robins to attack a prey in a novel situation (a form of boldness) and examined (i) repeatability of boldness (the propensity to take a risk), (ii) IIV of boldness, and (iii) whether there was a significant relationship between these two traits (a behavioural syndrome). We found that boldness was highly repeatable, that there were high levels of IIV in boldness, and that there was a negative relationship between boldness and IIV in boldness. This suggests that despite high levels of repeatability for this behaviour, there were also still significant differences in IIV among different individuals within the population. Moreover, bolder individuals had significantly less IIV in their boldness, which suggests that they were forming routines (which reduces behavioural variability) compared to shyer individuals. Our results definitively demonstrate that IIV itself varies across individuals and is linked with key behavioural traits, and we argue for the importance of future studies aimed at understanding its causes

  12. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    Directory of Open Access Journals (Sweden)

    Sha-Sha Yu

    2017-11-01

    Full Text Available AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL-Master and LenstarLS900 (Lenstar in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf, the steepest meridian power (Ks, mean power (Km, J0 and J45 were recorded. Intra-class correlation coefficients (ICCs, the coefficient of variance (COV, within subject standard deviation (Sw, and test-retest repeatability (2.77Sw were adopted to determine the repeatability. The 95% limit of agreement (95%LOA and Bland-Altman plots were used to assess comparability. RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  13. Prolonged Repeated Acupuncture Stimulation Induces Habituation Effects in Pain-Related Brain Areas: An fMRI Study

    Science.gov (United States)

    Li, Chuanfu; Yang, Jun; Park, Kyungmo; Wu, Hongli; Hu, Sheng; Zhang, Wei; Bu, Junjie; Xu, Chunsheng; Qiu, Bensheng; Zhang, Xiaochu

    2014-01-01

    Most previous studies of brain responses to acupuncture were designed to investigate the acupuncture instant effect while the cumulative effect that should be more important in clinical practice has seldom been discussed. In this study, the neural basis of the acupuncture cumulative effect was analyzed. For this experiment, forty healthy volunteers were recruited, in which more than 40 minutes of repeated acupuncture stimulation was implemented at acupoint Zhusanli (ST36). Three runs of acupuncture fMRI datasets were acquired, with each run consisting of two blocks of acupuncture stimulation. Besides general linear model (GLM) analysis, the cumulative effects of acupuncture were analyzed with analysis of covariance (ANCOVA) to find the association between the brain response and the cumulative duration of acupuncture stimulation in each stimulation block. The experimental results showed that the brain response in the initial stage was the strongest although the brain response to acupuncture was time-variant. In particular, the brain areas that were activated in the first block and the brain areas that demonstrated cumulative effects in the course of repeated acupuncture stimulation overlapped in the pain-related areas, including the bilateral middle cingulate cortex, the bilateral paracentral lobule, the SII, and the right thalamus. Furthermore, the cumulative effects demonstrated bimodal characteristics, i.e. the brain response was positive at the beginning, and became negative at the end. It was suggested that the cumulative effect of repeated acupuncture stimulation was consistent with the characteristic of habituation effects. This finding may explain the neurophysiologic mechanism underlying acupuncture analgesia. PMID:24821143

  14. Determinants of repeated abortion among women of reproductive age attending health facilities in Northern Ethiopia: a case–control study

    Directory of Open Access Journals (Sweden)

    Mussie Alemayehu

    2017-02-01

    Full Text Available Abstract Background Every year, an estimated 19–20 million unsafe abortions take place, almost all in developing countries, leading to 68,000 deaths and millions more injured many permanently. Many women throughout the world, experience more than one abortion in their lifetimes. Repeat abortion is an indicator of the larger problem of unintended pregnancy. This study aimed to identify determinants of repeat abortion in Tigray Region, Ethiopia. Methods Unmatched case–control study was conducted in hospitals in Tigray Region, northern Ethiopia, from November 2014 to June 2015. The sample included 105 cases and 204 controls, recruited from among women seeking abortion care at public hospitals. Clients having two or more abortions (“repeat abortion” were taken as cases and those who had a total of one abortion were taken as controls (“single abortion”. Cases were selected consecutive based on proportional to size allocation while systematic sampling was employed for controls. Data were analyzed using SPSS version 20.0. Binary and multiple variable logistic regression analyses were calculated with 95% CI. Results Mean age of cases was 24 years (±6.85 and 22 years (±6.25 for controls. 79.0% of cases had their sexual debut in less than 18 years of age compared to 57% of controls. 42.2% of controls and 23.8% of cases cited rape as the reason for having an abortion. Study participants who did not understand their fertility cycle and when they were most likely to conceive after menstruation (adjusted odds ratio [AOR] = 2.0, 95% confidence interval [CI]: 1.1–3.7, having a previous abortion using medication (AOR = 3.3, CI: 1.83, 6.11, having multiple sexual partners in the preceding 12 months (AOR = 4.4, CI: 2.39,8.45, perceiving that the abortion procedure is not painful (AOR = 2.3, CI: 1.31,4.26, initiating sexual intercourse before the age of 18 years (AOR = 2.7, CI: 1.49, 5.23 and disclosure to a third

  15. The Repeated Administration of Resveratrol Has Measurable Effects on Circulating T-Cell Subsets in Humans

    Directory of Open Access Journals (Sweden)

    J. Luis Espinoza

    2017-01-01

    Full Text Available Preclinical studies have shown that resveratrol exerts immunomodulatory effects with potential clinical value in the amelioration of autoimmune disorders and cancer prevention; however, little is known about the in vivo effects of this naturally occurring polyphenol on human immune cells. We assessed the effects of repeated doses of resveratrol (1000 mg/day for 28 days on circulating immune cells in healthy Japanese individuals. Resveratrol was safe and well tolerated and was associated with significant increases in the numbers of circulating γδ T cells and regulatory T cells and resulted in small, yet significant, decreases in the plasma levels of the proinflammatory cytokines TNF-α and MCP-1 and a significant increase in the plasma antioxidant activity compared with the corresponding antioxidant baseline activity and with that in four control individuals. In in vitro studies, resveratrol significantly improved the growth of γδ T cells and regulatory T cells. These findings demonstrate that resveratrol has some clear biological effects on human circulating immune cells. Further studies are necessary to interpret the long-term immunological changes associated with resveratrol treatment.

  16. Accuracy of velocities from repeated GPS surveys: relative positioning is concerned

    Science.gov (United States)

    Duman, Huseyin; Ugur Sanli, D.

    2016-04-01

    Over more than a decade, researchers have been interested in studying the accuracy of GPS positioning solutions. Recently, reporting the accuracy of GPS velocities has been added to this. Researchers studying landslide motion, tectonic motion, uplift, sea level rise, and subsidence still report results from GPS experiments in which repeated GPS measurements from short sessions are used. This motivated some other researchers to study the accuracy of GPS deformation rates/velocities from various repeated GPS surveys. In one of the efforts, the velocity accuracy was derived from repeated GPS static surveys using short observation sessions and Precise Point Positioning mode of GPS software. Velocities from short GPS sessions were compared with the velocities from 24 h sessions. The accuracy of velocities was obtained using statistical hypothesis testing and quantifying the accuracy of least squares estimation models. The results reveal that 45-60 % of the horizontal and none of the vertical solutions comply with the results from 24 h solutions. We argue that this case in which the data was evaluated using PPP should also apply to the case in which the data belonging to long GPS base lengths is processed using fundamental relative point positioning. To test this idea we chose the two IGS stations ANKR and NICO and derive their velocities from the reference stations held fixed in the stable EURASIAN plate. The University of Bern's GNSS software BERNESE was used to produce relative positioning solutions, and the results are compared with those of GIPSY/OASIS II PPP results. First impressions indicate that it is worth designing a global experiment and test these ideas in detail.

  17. Repeated checking induces uncertainty about future threat

    NARCIS (Netherlands)

    Giele, C.L.|info:eu-repo/dai/nl/318754460; Engelhard, I.M.|info:eu-repo/dai/nl/239681533; van den Hout, M.A.|info:eu-repo/dai/nl/070445354; Dek, E.C.P.|info:eu-repo/dai/nl/313959552; Damstra, Marianne; Douma, Ellen

    2015-01-01

    Studies have shown that obsessive-compulsive (OC) -like repeated checking paradoxically increases memory uncertainty. This study tested if checking also induces uncertainty about future threat by impairing the distinction between danger and safety cues. Participants (n = 54) engaged in a simulated

  18. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  19. Telomeric repeat-containing RNA (TERRA) related to polycystic ovary syndrome (PCOS).

    Science.gov (United States)

    Wang, Caiqin; Shen, Fengxian; Zhu, Yuning; Fang, Yuying; Lu, Shiming

    2017-04-01

    Telomeric repeat-containing RNA (TERRA) participates in the regulation of telomere length, and leucocyte telomere length (LTL) plays an important role in the pathophysiology of polycystic ovary syndrome (PCOS), but little is known about the role of TERRA in PCOS. To evaluate the role of TERRA and peripheral blood LTL in PCOS. Forty women with PCOS and 35 healthy women without PCOS were recruited. A prospective case-control study was performed. RNA fluorescence in situ hybridization (FISH) was used to detect TERRA expression in peripheral blood leucocyte. Quantitative PCR was used to measure TERRA expression and the mean LTL in the PCOS and control groups. We analysed the association between related clinical parameters and the age-adjusted ratio of the telomere repeat length (T/S ratio) or TERRA. Telomeric repeat-containing RNA was expressed in human peripheral blood leucocytes, and the signal was abolished after culture with RNase A. The age-adjusted LTLs were significantly longer in the PCOS group than in the control group (P PCOS group than in the control group (P PCOS group (r = 0·532, P = 0·002; r = -0·477, P = 0·017). We found TERRA expression in human peripheral blood leucocytes, and LTLs were positively associated with PCOS. TERRA and testosterone play an important role in the LTL regulation in PCOS. © 2016 John Wiley & Sons Ltd.

  20. A family of DNA repeats in Aspergillus nidulans has assimilated degenerated retrotransposons

    DEFF Research Database (Denmark)

    Nielsen, M.L.; Hermansen, T.D.; Aleksenko, Alexei Y.

    2001-01-01

    In the course of a chromosomal walk towards the centromere of chromosome IV of Aspergillus nidulans, several cross- hybridizing genomic cosmid clones were isolated. Restriction mapping of two such clones revealed that their restriction patterns were similar in a region of at least 15 kb, indicati......) phenomenon, first described in Neurospora crassa, may have operated in A. nidulans. The data indicate that this family of repeats has assimilated mobile elements that subsequently degenerated but then underwent further duplications as a part of the host repeats....... the presence of a large repeat. The nature of the repeat was further investigated by sequencing and Southern analysis. The study revealed a family of long dispersed repeats with a high degree of sequence similarity. The number and location of the repeats vary between wild isolates. Two copies of the repeat...

  1. simple sequence repeats (EST-SSR)

    African Journals Online (AJOL)

    Yomi

    2012-01-19

    Jan 19, 2012 ... 212 primer pairs selected, based on repeat patterns of n≥8 for di-, tri-, tetra- and penta-nucleotide repeat ... Cluster analysis revealed a high genetic similarity among the sugarcane (Saccharum spp.) breeding lines which could reduce the genetic gain in ..... The multiple allele characteristic of SSR com-.

  2. Repeated Prescribed Burning in Aspen

    Science.gov (United States)

    Donald A. Perala

    1974-01-01

    Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.

  3. Day-to-day repeatability of the Pulse Time Index of Norm

    Directory of Open Access Journals (Sweden)

    Posokhov IN

    2014-02-01

    Full Text Available Igor N Posokhov,1 Aleksandra O Konradi,2 Eugeny V Shlyakhto,2 Oleg V Mamontov,2 Artemy V Orlov,3 Anatoly N Rogoza4 1Hemodynamic Laboratory Ltd, Nizhniy Novgorod, 2Almazov Federal Heart, Blood and Endocrinology Centre, Saint Petersburg, 3Department 65 Competitive System Analysis, National Research Nuclear University, Moscow, 4Cardiology Research Center, Moscow, Russia Abstract: The pulse wave velocity (PWV threshold for hypertensive target organ damage is presently set at 10 meters per second. New 24-hour monitors (eg, BPLab® and Vasotens® provide several PWV measurements over a period of 24–72 hours. A new parameter, ie, the Pulse Time Index of Norm (PTIN, can be calculated from these data. The PTIN is defined as the percentage of a 24-hour period during which the PWV does not exceed 10 meters per second. The aim of the present study was to test the new PTIN for clinical feasibility using day-to-day repeatability analysis. Oscillometrically generated waveform files (n=85, which were previously used for research studies, were reanalyzed using the new 2013 version software of the Vasotens technology program, which enables calculation of PTIN. The intraclass correlation coefficient was 0.98 and Cronbach's alpha was 0.97, indicating that the PTIN has excellent day-to-day repeatability and internal consistency. The present results show adequate repeatability, and PTIN assessment using the Vasotens technology appears to be feasible. Keywords: pulse wave velocity, ambulatory, 24-hour, monitoring, Pulse Time Index of Norm, arterial stiffness

  4. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  5. Childhood experiences and repeated suicidal behavior

    DEFF Research Database (Denmark)

    Krarup, Gertrud; Nielsen, Bent; Rask, P

    1991-01-01

    The aim of this study was to elucidate the influence of various events in childhood on suicidal behavior in adult age. For this purpose, 99 patients admitted to the Department of Psychiatry of Odense University Hospital after making a suicide attempt were followed for 5 years, to register repeated...... that the psychological climate of the home may be more important than the rupture of early home life. It is noteworthy that the group of repeaters, as against the first-evers, could be characterized by personality disorders and abuse, especially of alcohol: disorders known to be precipitated by a discordant childhood....... It is commonly agreed that the experience in childhood of suicidal behavior among family members or other persons in the close environment is of importance in future suicidal risk. The results of this study indicate that the predictive value of this factor mainly applies to attempts with no fatal outcome...

  6. Sex differences in behavioral and PKA cascade responses to repeated cocaine administration.

    Science.gov (United States)

    Zhou, Luyi; Sun, Wei-Lun; Weierstall, Karen; Minerly, Ana Christina; Weiner, Jan; Jenab, Shirzad; Quinones-Jenab, Vanya

    2016-10-01

    Previous studies have shown sex different patterns in behavioral responses to cocaine. Here, we used between-subject experiment design to study whether sex differences exist in the development of behavioral sensitization and tolerance to repeated cocaine, as well as the role of protein kinase A (PKA) signaling cascade in this process. Ambulatory and rearing responses were recorded in male and female rats after 1 to 14 days of administration of saline or cocaine (15 mg/kg; ip). Correspondent PKA-associated signaling in the nucleus accumbens (NAc) and caudate-putamen (CPu) was measured at each time point. Our results showed that females exhibited higher cocaine-induced behavioral responses and developed behavioral sensitization and tolerance faster than males. Whereas females developed behavioral sensitization to cocaine after 2 days and tolerance after 14 days, male rats developed sensitization after 5 days. In addition, cocaine induced a sexual dimorphic pattern in the progression of neuronal adaptations on the PKA cascade signaling in region (NAc vs. CPu) and time (days of cocaine administration)-dependent manners. In general, more PKA signaling cascade changes were found in the NAc of males on day 5 and in the CPu of females with repeated cocaine injection. In addition, in females, behavioral activities positively correlated with FosB levels in the NAc and CPu and negatively correlated with Cdk5 and p35 in the CPu, while no correlation was observed in males. Our studies suggest that repeated cocaine administration induced different patterns of behavioral and molecular responses in the PKA cascade in male and female rats.

  7. Single, 14-Day, and 13-Week Repeated Dose Toxicity Studies of Daily Oral Gelidium elegans Extract Administration to Rats.

    Science.gov (United States)

    Choi, Jia; Ryu, Su-Jung; Kim, Kui-Jin; Kim, Hyung-Min; Chung, Hee-Chul; Lee, Boo-Yong

    2018-01-20

    Gelidium elegans extract (GEE) is derived from a red alga from the Asia-Pacific region, which has antioxidant, anti-adipogenic, and anti-hyperglycemic effects. However, detailed studies of the toxicology of GEE have not been performed. We evaluated the single oral dose toxicity of GEE in male and female Sprague-Dawley (CD) rats. GEE did not cause deaths or have toxic effects at dosages of 5000 mg/kg/day, although compound-colored stools and diarrhea were observed in both sexes, which lasted 5000 mg/kg. We next evaluated the repeated oral dose toxicity of GEE in CD rats over 14 days and 13 weeks. GEE did not induce any significant toxicological changes in either sex at 2000 mg/kg/day. Repeated oral dose toxicity studies showed no adverse effects, in terms of clinical signs, mortality, body mass, food consumption, ophthalmic examination, urinalysis, hematology, serum biochemistry, necropsy, organ masses, or histopathology, at dosages of 500, 1000, or 2000 mg/kg/day. The no observed adverse effect level (NOAEL) for GEE is thus likely to be >2000 mg/kg/day, and no pathology was identified in potential target organs. Therefore, this study indicates that repeated oral dosing with GEE is safe in CD rats.

  8. Predictive value of repeated measurements of luteal progesterone and estradiol levels in patients with intrauterine insemination and controlled ovarian stimulation.

    Science.gov (United States)

    Bakas, Panagiotis; Simopoulou, Maria; Giner, Maria; Drakakis, Petros; Panagopoulos, Perikles; Vlahos, Nikolaos

    2017-10-01

    The objective of this study is to assess if the difference of repeated measurements of estradiol and progesterone during luteal phase predict the outcome of intrauterine insemination. Prospective study. Reproductive clinic. 126 patients with infertility. Patients underwent controlled ovarian stimulation with recombinant FSH (50-150 IU/d). The day of IUI patients were given p.o natural micronized progesterone in a dose of 100 mg/tds. The area under the receiver characteristic operating curve (ROC curve) in predicting clinical pregnancy for % change of estradiol level on days 6 and 10 was 0.892 with 95% CI: 0.82-0.94. A cutoff value of change > -29.5% had a sensitivity of 85.7 with a specificity of 90.2. The corresponding ROC curve for % change of progesterone level was 0.839 with 95% CI: 0.76-0.90. A cutoff value of change > -33% had a sensitivity of 85 with a specificity of 75. The % change of estradiol and progesterone between days 6 and 10 has a predictive ability of pregnancy after IUI with COS of 89.2% and 83.4%, respectively. The addition of % of progesterone to % change of estradiol does not improve the predictive ability of % estradiol and should not be used.

  9. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  10. What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?

    Science.gov (United States)

    Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E

    2018-03-01

    Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.

  11. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    Science.gov (United States)

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  12. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    1999-01-01

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  13. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  14. RNA FISH for detecting expanded repeats in human diseases.

    Science.gov (United States)

    Urbanek, Martyna O; Krzyzosiak, Wlodzimierz J

    2016-04-01

    RNA fluorescence in situ hybridization (FISH) is a widely used technique for detecting transcripts in fixed cells and tissues. Many variants of RNA FISH have been proposed to increase signal strength, resolution and target specificity. The current variants of this technique facilitate the detection of the subcellular localization of transcripts at a single molecule level. Among the applications of RNA FISH are studies on nuclear RNA foci in diseases resulting from the expansion of tri-, tetra-, penta- and hexanucleotide repeats present in different single genes. The partial or complete retention of mutant transcripts forming RNA aggregates within the nucleoplasm has been shown in multiple cellular disease models and in the tissues of patients affected with these atypical mutations. Relevant diseases include, among others, myotonic dystrophy type 1 (DM1) with CUG repeats, Huntington's disease (HD) and spinocerebellar ataxia type 3 (SCA3) with CAG repeats, fragile X-associated tremor/ataxia syndrome (FXTAS) with CGG repeats, myotonic dystrophy type 2 (DM2) with CCUG repeats, amyotrophic lateral sclerosis/frontotemporal dementia (ALS/FTD) with GGGGCC repeats and spinocerebellar ataxia type 32 (SCA32) with GGCCUG. In this article, we summarize the results obtained with FISH to examine RNA nuclear inclusions. We provide a detailed protocol for detecting RNAs containing expanded CAG and CUG repeats in different cellular models, including fibroblasts, lymphoblasts, induced pluripotent stem cells and murine and human neuronal progenitors. We also present the results of the first single-molecule FISH application in a cellular model of polyglutamine disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Cognitive outcome in adolescents and young adults after repeat courses of antenatal corticosteroids.

    Science.gov (United States)

    Stålnacke, Johanna; Diaz Heijtz, Rochellys; Norberg, Hanna; Norman, Mikael; Smedler, Ann-Charlotte; Forssberg, Hans

    2013-08-01

    To investigate whether repeat courses of antenatal corticosteroids have long-term effects on cognitive and psychological functioning. In a prospective cohort study, 58 adolescents and young adults (36 males) who had been exposed to 2-9 weekly courses of betamethasone in utero were assessed with neuropsychological tests and behavior self-reports. Unexposed subjects (n = 44, 25 males) matched for age, sex, and gestational age at birth served as a comparison group. In addition, individuals exposed in utero to a single course (n = 25, 14 males) were included for dose-response analysis. Group differences were investigated using multilevel linear modeling. Mean scores obtained in 2 measures of attention and speed were significantly lower in subjects exposed to 2 or more antenatal corticosteroids courses (Symbol Search, P = .009; Digit Span Forward, P = .02), but these were not dose-dependent. Exposure to repeat courses of antenatal corticosteroids was not associated with general deficits in higher cognitive functions, self-reported attention, adaptability, or overall psychological function. Although this study indicates that repeat exposure to antenatal corticosteroids may have an impact on aspects of executive functioning, it does not provide support for the prevailing concern that such fetal exposure will have a major adverse impact on cognitive functions and psychological health later in life. Copyright © 2013 Mosby, Inc. All rights reserved.

  16. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    Science.gov (United States)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  17. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation

    International Nuclear Information System (INIS)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-01-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C. Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland–Altman method was used to assess agreement between them. The devices showed agreement in overall tracking of changes in SO2. Test–retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range. Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative. (paper)

  18. Poor methodological detail precludes experimental repeatability and hampers synthesis in ecology.

    Science.gov (United States)

    Haddaway, Neal R; Verhoeven, Jos T A

    2015-10-01

    Despite the scientific method's central tenets of reproducibility (the ability to obtain similar results when repeated) and repeatability (the ability to replicate an experiment based on methods described), published ecological research continues to fail to provide sufficient methodological detail to allow either repeatability of verification. Recent systematic reviews highlight the problem, with one example demonstrating that an average of 13% of studies per year (±8.0 [SD]) failed to report sample sizes. The problem affects the ability to verify the accuracy of any analysis, to repeat methods used, and to assimilate the study findings into powerful and useful meta-analyses. The problem is common in a variety of ecological topics examined to date, and despite previous calls for improved reporting and metadata archiving, which could indirectly alleviate the problem, there is no indication of an improvement in reporting standards over time. Here, we call on authors, editors, and peer reviewers to consider repeatability as a top priority when evaluating research manuscripts, bearing in mind that legacy and integration into the evidence base can drastically improve the impact of individual research reports.

  19. Current practice of usual clinic blood pressure measurement in people with and without diabetes: a survey and prospective 'mystery shopper' study in UK primary care.

    Science.gov (United States)

    Stevens, Sarah L; McManus, Richard J; Stevens, Richard John

    2018-04-12

    Hypertension trials and epidemiological studies use multiple clinic blood pressure (BP) measurements at each visit. Repeat measurement is also recommended in international guidance; however, little is known about how BP is measured routinely. This is important for individual patient management and because routinely recorded readings form part of research databases. We aimed to determine the current practice of BP measurement during routine general practice appointments. (1) An online cross-sectional survey and (2) a prospective 'mystery shopper' study where patients agreed to report how BP was measured during their next appointment. Primary care. Patient charity/involvement group members completing an online survey between July 2015 and January 2016. 334 participants completed the prospective study (51.5% male, mean age=59.3 years) of which 279 (83.5%) had diabetes. Proportion of patients having BP measured according to guidelines. 217 participants with (183) and without diabetes (34) had their BP measured at their last appointment. BP was measured in line with UK guidance in 63.7% and 60.0% of participants with and without diabetes, respectively. Initial pressures were significantly higher in those who had their BP measured more than once compared with only once (p=0.016/0.089 systolic and p<0.001/p=0.022 diastolic, in patients with/without diabetes, respectively). Current practice of routine BP measurement in UK primary care is often concordant with guidelines for repeat measurement. Further studies are required to confirm findings in broader populations, to confirm when a third repeat reading is obtained routinely and to assess adherence to other aspects of BP measurement guidance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. The Pentapeptide Repeat Proteins

    OpenAIRE

    Vetting, Matthew W.; Hegde, Subray S.; Fajardo, J. Eduardo; Fiser, Andras; Roderick, Steven L.; Takiff, Howard E.; Blanchard, John S.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S,T,A,V][D,N][L,F]-[S,T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Myc...

  1. Repeat cesarean delivery: what indications are recorded in the medical chart?

    Science.gov (United States)

    Lydon-Rochelle, Mona T; Gardella, Carolyn; Cárdenas, Vicky; Easterling, Thomas R

    2006-03-01

    National surveillance estimates reported a troubling 63 percent decline in the rate of vaginal birth after cesarean delivery (VBAC) from 1996 (28.3%) to 2003 (10.6%), with subsequent rising rates of repeat cesarean delivery. The study objective was to examine patterns of documented indications for repeat cesarean delivery in women with and without labor. We conducted a population-based validation study of 19 nonfederal short-stay hospitals in Washington state. Of the 4,541 women who had live births in 2000, 11 percent (n = 493) had repeat cesarean without labor and 3 percent (n = 138) had repeat cesarean with labor. Incidence of medical conditions and pregnancy complications, patterns of documented indications for repeat cesarean delivery, and perioperative complications in relation to repeat cesarean delivery with and without labor were calculated. Of the 493 women who underwent a repeat cesarean delivery without labor, "elective"(36%) and "maternal request"(18%) were the most common indications. Indications for maternal medical conditions (3.0%) were uncommon. Among the 138 women with repeat cesarean delivery with labor, 60.1 percent had failure to progress, 24.6 percent a non-reassuring fetal heart rate, 8.0 percent cephalopelvic disproportion, and 7.2 percent maternal request during labor. Fetal indications were less common (5.8%). Breech, failed vacuum, abruptio placentae, maternal complications, and failed forceps were all indicated less than 5.0 percent. Women's perioperative complications did not vary significantly between women without and with labor. Regardless of a woman's labor status, nearly 10 percent of women with repeat cesarean delivery had no documented indication as to why a cesarean delivery was performed. "Elective" and "maternal request" were common indications among women undergoing repeat cesarean delivery without labor, and nearly 10 percent of women had undocumented indications for repeat cesarean delivery in their medical record

  2. Prediction and repeatability of milk coagulation properties and curd-firming modeling parameters of ovine milk using Fourier-transform infrared spectroscopy and Bayesian models.

    Science.gov (United States)

    Ferragina, A; Cipolat-Gotet, C; Cecchinato, A; Pazzola, M; Dettori, M L; Vacca, G M; Bittante, G

    2017-05-01

    The aim of this study was to apply Bayesian models to the Fourier-transform infrared spectroscopy spectra of individual sheep milk samples to derive calibration equations to predict traditional and modeled milk coagulation properties (MCP), and to assess the repeatability of MCP measures and their predictions. Data consisted of 1,002 individual milk samples collected from Sarda ewes reared in 22 farms in the region of Sardinia (Italy) for which MCP and modeled curd-firming parameters were available. Two milk samples were taken from 87 ewes and analyzed with the aim of estimating repeatability, whereas a single sample was taken from the other 915 ewes. Therefore, a total of 1,089 analyses were performed. For each sample, 2 spectra in the infrared region 5,011 to 925 cm -1 were available and averaged before data analysis. BayesB models were used to calibrate equations for each of the traits. Prediction accuracy was estimated for each trait and model using 20 replicates of a training-testing validation procedure. The repeatability of MCP measures and their predictions were also compared. The correlations between measured and predicted traits, in the external validation, were always higher than 0.5 (0.88 for rennet coagulation time). We confirmed that the most important element for finding the prediction accuracy is the repeatability of the gold standard analyses used for building calibration equations. Repeatability measures of the predicted traits were generally high (≥95%), even for those traits with moderate analytical repeatability. Our results show that Bayesian models applied to Fourier-transform infrared spectra are powerful tools for cheap and rapid prediction of important traits in ovine milk and, compared with other methods, could help in the interpretation of results. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Magnetic Repeat Station Network on the Baltic Sea — Why So Needed?

    Directory of Open Access Journals (Sweden)

    Welker Elżbieta

    2017-12-01

    Full Text Available The development of navigation systems requires more and more accurate base data. Currently, attention is paid to utilization of geophysical fields — gravitational and magnetic ones — for navigation purposes. The Earth’s magnetic field distribution — both onshore and offshore — is complicated and variable in time. Hence, it is essential to precisely know the secular variations in the area of interest. In the case of Baltic Sea, this involves establishing (re-establishing of a marine network of secular points (repeat stations and regular magnetic measurements of the three independent components of the Earth’s magnetic field. Such measurements require equipment that ensures not only high stability, but also information about sensors’ orientation in relation to geographic north and to the level. This article presents a new project of the Baltic network of repeat stations and gives a solution for the instruments usable for quasi-absolute magnetic measurements.

  4. Aberrant approach-avoidance conflict resolution following repeated cocaine pre-exposure.

    Science.gov (United States)

    Nguyen, David; Schumacher, Anett; Erb, Suzanne; Ito, Rutsuko

    2015-10-01

    Addiction is characterized by persistence to seek drug reinforcement despite negative consequences. Drug-induced aberrations in approach and avoidance processing likely facilitate the sustenance of addiction pathology. Currently, the effects of repeated drug exposure on the resolution of conflicting approach and avoidance motivational signals have yet to be thoroughly investigated. The present study sought to investigate the effects of cocaine pre-exposure on conflict resolution using novel approach-avoidance paradigms. We used a novel mixed-valence conditioning paradigm to condition cocaine-pre-exposed rats to associate visuo-tactile cues with either the delivery of sucrose reward or shock punishment in the arms in which the cues were presented. Following training, exploration of an arm containing a superimposition of the cues was assessed as a measure of conflict resolution behavior. We also used a mixed-valence runway paradigm wherein cocaine-pre-exposed rats traversed an alleyway toward a goal compartment to receive a pairing of sucrose reward and shock punishment. Latency to enter the goal compartment across trials was taken as a measure of motivational conflict. Our results reveal that cocaine pre-exposure attenuated learning for the aversive cue association in our conditioning paradigm and enhanced preference for mixed-valence stimuli in both paradigms. Repeated cocaine pre-exposure allows appetitive approach motivations to gain greater influence over behavioral output in the context of motivational conflict, due to aberrant positive and negative incentive motivational processing.

  5. Feasibility and repeatability of cold and mechanical quantitative sensory testing in normal dogs

    Science.gov (United States)

    Briley, Jessica D.; Williams, Morika D.; Freire, Mila; Griffith, Emily H.; Lascelles, B. Duncan X.

    2015-01-01

    Feasibility and inter-session repeatability of cold and mechanical quantitative sensory testing (QST) were assessed in 24 normal dogs. Cold thermal latencies were evaluated using a thermal probe (0 °C) applied to three pelvic limb sites. Mechanical thresholds were measured using an electronic von Frey anesthesiometer (EVF) and a blunt-probed pressure algometer (PA) applied to the dorsal aspect of the metatarsus. All QST trials were performed with dogs in lateral recumbency. Collection of cold QST data was easy (feasible) in 19/24 (79%) dogs. However, only 18.4%, 18.9% and 13.2% of cold QST trials elicited a response at the medial tibia, third digital pad and plantar metatarsal regions, respectively. Collection of mechanical QST data was easy (feasible) in 20/24 (83%) dogs for both EVF and PA. At consecutive sampling times, approximately 2 weeks apart, the average EVF sensory thresholds were 414 ± 186 g and 379 ± 166 g, respectively, and the average PA sensory thresholds were 1089 ± 414 g and 1028 ± 331 g, respectively. There was no significant difference in inter-session or inter-limb threshold values for either mechanical QST device. The cold QST protocol in this study was achievable, but did not provide consistently quantifiable results. Both mechanical QST devices tested provided repeatable, reliable sensory threshold measurements in normal, client-owned dogs. These findings contribute to the validation of the EVF and PA as tools to obtain repeated QST data over time in dogs to assess somatosensory processing changes. PMID:24268475

  6. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  7. Study of reproducibility of measurements with the spectrometer of Bonner multispheres

    International Nuclear Information System (INIS)

    Azevedo, G.A.; Pereira, W.W.; Patrao, K.C.S.; Fonseca, E.S.

    2013-01-01

    This work aims to study the metrological behavior of the Bonner Multisphere Spectrometer (BMS) of the LN / LNMRI / IRD - Laboratorio Metrologia de Neutrons / Laboratorio Nacional de Metrologia e Radiacao Ionizante / Instituto de Radioprotecao e Dosimetria, for measurements in repeatability and reproducibility conditions. Initially, a simulation was done by applying the Monte Carlo method, using the MCNP code and respecting the ISO 8529-1 (2001), using the sources of Californium ( 252 Cf), Americium-Beryllium ( 241 AmBe) and californium in heavy water (Cf + D 2 O), all located at a distance of 100 cm from the neutron detector ( 6 Li (Eu) - crystal scintillator). In this program, the counting of neutrons that are captured by the detector was made. The source is located in the center of a sphere of radius 300 cm. Analyzes the impact of these neutrons in a point of the sphere wall, which in this case acted as a neutron detector and from there, it is estimated the number of neutrons that collide in the whole sphere. The purpose is to obtain the neutron count for different energy bands in a solid field of neutrons, since they have a spectrum ranging from a low to a high energy that can also vary within a particular environment. Wishes to obtain new fields with different sources and moderators materials to be used as new reference fields. Measurements are being conducted for these fields, with the aim of analyzing the variability conditions of the measurement (repeatability and reproducibility) in LEN - Laboratorio de Espectrometria de Neutrons of the LN/LMNRI/IRD. Thus, the spectrometer will be used to improve both the knowledge of the spectrum as the standard of neutrons of the lab, proving that a spectrometry is essential for correct measurement

  8. Intra-rater repeatability of gait parameters in healthy adults during self-paced treadmill-based virtual reality walking.

    Science.gov (United States)

    Al-Amri, Mohammad; Al Balushi, Hilal; Mashabi, Abdulrhman

    2017-12-01

    Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, gait performance over time.

  9. Consequences of repeated blood-brain barrier disruption in football players.

    Directory of Open Access Journals (Sweden)

    Nicola Marchi

    Full Text Available The acknowledgement of risks for traumatic brain injury in American football players has prompted studies for sideline concussion diagnosis and testing for neurological deficits. While concussions are recognized etiological factors for a spectrum of neurological sequelae, the consequences of sub-concussive events are unclear. We tested the hypothesis that blood-brain barrier disruption (BBBD and the accompanying surge of the astrocytic protein S100B in blood may cause an immune response associated with production of auto-antibodies. We also wished to determine whether these events result in disrupted white matter on diffusion tensor imaging (DT scans. Players from three college football teams were enrolled (total of 67 volunteers. None of the players experienced a concussion. Blood samples were collected before and after games (n = 57; the number of head hits in all players was monitored by movie review and post-game interviews. S100B serum levels and auto-antibodies against S100B were measured and correlated by direct and reverse immunoassays (n = 15 players; 5 games. A subset of players underwent DTI scans pre- and post-season and after a 6-month interval (n = 10. Cognitive and functional assessments were also performed. After a game, transient BBB damage measured by serum S100B was detected only in players experiencing the greatest number of sub-concussive head hits. Elevated levels of auto-antibodies against S100B were elevated only after repeated sub-concussive events characterized by BBBD. Serum levels of S100B auto-antibodies also predicted persistence of MRI-DTI abnormalities which in turn correlated with cognitive changes. Even in the absence of concussion, football players may experience repeated BBBD and serum surges of the potential auto-antigen S100B. The correlation of serum S100B, auto-antibodies and DTI changes support a link between repeated BBBD and future risk for cognitive changes.

  10. Consequences of Repeated Blood-Brain Barrier Disruption in Football Players

    Science.gov (United States)

    Puvenna, Vikram; Janigro, Mattia; Ghosh, Chaitali; Zhong, Jianhui; Zhu, Tong; Blackman, Eric; Stewart, Desiree; Ellis, Jasmina; Butler, Robert; Janigro, Damir

    2013-01-01

    The acknowledgement of risks for traumatic brain injury in American football players has prompted studies for sideline concussion diagnosis and testing for neurological deficits. While concussions are recognized etiological factors for a spectrum of neurological sequelae, the consequences of sub-concussive events are unclear. We tested the hypothesis that blood-brain barrier disruption (BBBD) and the accompanying surge of the astrocytic protein S100B in blood may cause an immune response associated with production of auto-antibodies. We also wished to determine whether these events result in disrupted white matter on diffusion tensor imaging (DT) scans. Players from three college football teams were enrolled (total of 67 volunteers). None of the players experienced a concussion. Blood samples were collected before and after games (n = 57); the number of head hits in all players was monitored by movie review and post-game interviews. S100B serum levels and auto-antibodies against S100B were measured and correlated by direct and reverse immunoassays (n = 15 players; 5 games). A subset of players underwent DTI scans pre- and post-season and after a 6-month interval (n = 10). Cognitive and functional assessments were also performed. After a game, transient BBB damage measured by serum S100B was detected only in players experiencing the greatest number of sub-concussive head hits. Elevated levels of auto-antibodies against S100B were elevated only after repeated sub-concussive events characterized by BBBD. Serum levels of S100B auto-antibodies also predicted persistence of MRI-DTI abnormalities which in turn correlated with cognitive changes. Even in the absence of concussion, football players may experience repeated BBBD and serum surges of the potential auto-antigen S100B. The correlation of serum S100B, auto-antibodies and DTI changes support a link between repeated BBBD and future risk for cognitive changes. PMID:23483891

  11. Usefulness of repeated N-terminal pro-B-type natriuretic peptide measurements as incremental predictor for long-term cardiovascular outcome after vascular surgery.

    Science.gov (United States)

    Goei, Dustin; van Kuijk, Jan-Peter; Flu, Willem-Jan; Hoeks, Sanne E; Chonchol, Michel; Verhagen, Hence J M; Bax, Jeroen J; Poldermans, Don

    2011-02-15

    Plasma N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) levels improve preoperative cardiac risk stratification in vascular surgery patients. However, single preoperative measurements of NT-pro-BNP cannot take into account the hemodynamic stress caused by anesthesia and surgery. Therefore, the aim of the present study was to assess the incremental predictive value of changes in NT-pro-BNP during the perioperative period for long-term cardiac mortality. Detailed cardiac histories, rest left ventricular echocardiography, and NT-pro-BNP levels were obtained in 144 patients before vascular surgery and before discharge. The study end point was the occurrence of cardiovascular death during a median follow-up period of 13 months (interquartile range 5 to 20). Preoperatively, the median NT-pro-BNP level in the study population was 314 pg/ml (interquartile range 136 to 1,351), which increased to a median level of 1,505 pg/ml (interquartile range 404 to 6,453) before discharge. During the follow-up period, 29 patients (20%) died, 27 (93%) from cardiovascular causes. The median difference in NT-pro-BNP in the survivors was 665 pg/ml, compared to 5,336 pg/ml in the patients who died (p = 0.01). Multivariate Cox regression analyses, adjusted for cardiac history and cardiovascular risk factors (age, angina pectoris, myocardial infarction, stroke, diabetes mellitus, renal dysfunction, body mass index, type of surgery and the left ventricular ejection fraction), demonstrated that the difference in NT-pro-BNP level between pre- and postoperative measurement was the strongest independent predictor of cardiac outcome (hazard ratio 3.06, 95% confidence interval 1.36 to 6.91). In conclusion, the change in NT-pro-BNP, indicated by repeated measurements before surgery and before discharge is the strongest predictor of cardiac outcomes in patients who undergo vascular surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Correlation between explosive strength, aerobic power and repeated sprint ability in elite basketball players.

    Science.gov (United States)

    Stojanovic, M D; Ostojic, S M; Calleja-González, J; Milosevic, Z; Mikic, M

    2012-08-01

    The aim of this study was to examine the relationship between explosive strength and aerobic power with basketball-specific repeated sprint ability in elite male basketball players. Twenty-four elite basketball players (age 22.2±3.4 years, height 197.1±6.2 cm, weight 95.7±8.8 kg; training experience 11.0±3.1 years; mean±SD), participated in the study. Subjects performed countermovement jump (CMJ) test and incremental pseudo-ramp test protocol with measured CMJ height and VO2max, respectively. Specific repeated sprint ability (RSA) test was conducted, with total sprinting time (summation of 10 sprint times - RSAtot) and sprint decrement (fatigue index - RSAFI) calculated. Significant decrements in sprint performance from the eight 30-m sprint (Pbasketball players. It seems that coaches and strength and conditioning professionals should devote additional time for explosive strength development in elite basketball players during preparatory period to enhance RSA performance.

  13. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  14. A new rapid method to measure human platelet cholesterol: a pilot study.

    Science.gov (United States)

    Jagroop, I Anita; Persaud, Jahm Want; Mikhailidis, Dimitri P

    2011-01-01

    Platelet cholesterol (PC) could be used to assess "tissue" cholesterol of patients with vascular disease. However, the methods available so far to measure PC involve a complex extraction process. We developed a rapid method to measure PC and assessed its correlation with serum total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), LDL-C/HDL-C ratio, triglycerides (TG), and non-HDL-C. We assessed repeatability (20 times, 3 participants) and reproducibility (8 times, 2 participants). A group of 47 healthy participants was studied. Blood was collected to analyze serum TC, LDL-C, HDL-C, and TG. Citrated blood was used to prepare a platelet pellet. A "clear soup" was produced (by disrupting this pellet using freeze-thaw and sonication cycles) and used to measure PC. Repeatability of PC showed a coefficient of variation (CV) of 4.8%. The reproducibility of PC over a period of 2 months was CV 7.5% and 8.1% (8 measurements for 2 participants). The PC of participants with serum LDL-C >2.6 mmol/L (treatment goal recommended by the National Cholesterol Education Program Adult Treatment Panel III) was 377 ± 120 μmol/10(12) platelets (n = 25). There was a significant correlation (Spearman, correlation coefficient) of PC (n = 25) with serum LDL-C (r(s) = 0.45, P = .02), LDL-C/HDL-C (r(s) = 0.45, P = .02), TG (r(s) = 0.43, P = .03), and non-HDL-C (r(s) = 0.53, P = .007). This technique of measuring PC has the advantage of being reproducible, fast, and simpler than previous methods. Thus, it may be useful for multiple sampling when investigating changes in PC in hypercholesterolemic patients. More extensive evaluation is necessary.

  15. Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

    Science.gov (United States)

    Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda

    2015-01-01

    To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (Pcontact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.

  16. Single, 14-Day, and 13-Week Repeated Dose Toxicity Studies of Daily Oral Gelidium elegans Extract Administration to Rats

    Directory of Open Access Journals (Sweden)

    Jia Choi

    2018-01-01

    Full Text Available Gelidium elegans extract (GEE is derived from a red alga from the Asia–Pacific region, which has antioxidant, anti-adipogenic, and anti-hyperglycemic effects. However, detailed studies of the toxicology of GEE have not been performed. We evaluated the single oral dose toxicity of GEE in male and female Sprague-Dawley (CD rats. GEE did not cause deaths or have toxic effects at dosages of 5000 mg/kg/day, although compound-colored stools and diarrhea were observed in both sexes, which lasted <2 days. Therefore, the LD50 of GEE is likely to be >5000 mg/kg. We next evaluated the repeated oral dose toxicity of GEE in CD rats over 14 days and 13 weeks. GEE did not induce any significant toxicological changes in either sex at 2000 mg/kg/day. Repeated oral dose toxicity studies showed no adverse effects, in terms of clinical signs, mortality, body mass, food consumption, ophthalmic examination, urinalysis, hematology, serum biochemistry, necropsy, organ masses, or histopathology, at dosages of 500, 1000, or 2000 mg/kg/day. The no observed adverse effect level (NOAEL for GEE is thus likely to be >2000 mg/kg/day, and no pathology was identified in potential target organs. Therefore, this study indicates that repeated oral dosing with GEE is safe in CD rats.

  17. Smooth muscle fatigue due to repeated urinary bladder neurostimulation: an in vivo study.

    Science.gov (United States)

    Bross, S; Schumacher, S; Scheepe, J R; Seif, C; Jünemann, K P; Alken, P

    1999-01-01

    The presented study investigates the influence of different pause lengths between two consecutive stimulations of the S3 roots on intravesical pressure during bladder neurostimulation. In eight male foxhounds (aged 7-18 months), laminectomy and placement of a modified Brindley electrode were performed. In four series with different pause lengths between two consecutive stimulations (1, 3, 5, and 15 min), the maximum intravesical pressure was measured during stimulation. The changes in intravesical pressure were registered in these four series, each series with six stimulations. A 15-min interval elapsed before the commencement of each series. In the series with a pause length of 15 min, the consecutive stimulations did not result in significant changes in maximum intravesical pressure. In the 5-min series, a significant decrease in intravesical pressure was not observed after the third stimulation. In the 3-min series, a significant decrease was seen at almost every stimulation (average decrease of 3.8% per stimulation) and in the 1-min series, a significant decrease was also observed at almost every stimulation (average decrease of 5.9% per stimulation). The results of repeated bladder neurostimulation demonstrate that the maximum intravesical pressure is dependent on the pause length between two consecutive stimulations. The detrusor muscle showed reversible and short-lived signs of fatigue. This implies the importance of a minimum 5-min interval between two subsequent stimulations. A pause length <5 min leads to a falsification of the results and thus to lower validity of the investigation.

  18. Performance of bias-correction methods for exposure measurement error using repeated measurements with and without missing data.

    Science.gov (United States)

    Batistatou, Evridiki; McNamee, Roseanne

    2012-12-10

    It is known that measurement error leads to bias in assessing exposure effects, which can however, be corrected if independent replicates are available. For expensive replicates, two-stage (2S) studies that produce data 'missing by design', may be preferred over a single-stage (1S) study, because in the second stage, measurement of replicates is restricted to a sample of first-stage subjects. Motivated by an occupational study on the acute effect of carbon black exposure on respiratory morbidity, we compare the performance of several bias-correction methods for both designs in a simulation study: an instrumental variable method (EVROS IV) based on grouping strategies, which had been recommended especially when measurement error is large, the regression calibration and the simulation extrapolation methods. For the 2S design, either the problem of 'missing' data was ignored or the 'missing' data were imputed using multiple imputations. Both in 1S and 2S designs, in the case of small or moderate measurement error, regression calibration was shown to be the preferred approach in terms of root mean square error. For 2S designs, regression calibration as implemented by Stata software is not recommended in contrast to our implementation of this method; the 'problematic' implementation of regression calibration although substantially improved with use of multiple imputations. The EVROS IV method, under a good/fairly good grouping, outperforms the regression calibration approach in both design scenarios when exposure mismeasurement is severe. Both in 1S and 2S designs with moderate or large measurement error, simulation extrapolation severely failed to correct for bias. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Single and 2-week repeated intravenous dose toxicity studies of disodium mercaptoundecahydro-closo-dodecaborate in rats

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Fumio; Yabuuchi, Kazuya; Ohno, Kouji; Muraoka, Yoshihiro [Shionogi and Co. Ltd., Toyonaka, Osaka (Japan). Developmental Research Lab.; Ikeuchi, Isao

    1998-10-01

    Disodium mercaptoundecahydro-closo-dodecaborate (BSH) is a boron compound used in Boron Neutron Capture Therapy for malignant brain tumors. Intravenous single and 2-week repeated dose toxicity studies of BSH were performed in Sprague-Dawley rats. In the single-dose study, BSH was administered at doses of 100, 300 or 600 mg/kg. Death occurred within 10 min (acute type) or from 5 hr to 2 days (delayed type) after dosing in the 600 mg/kg group. No differences in mortality by sex and dosing speed were observed. Major causes of death were considered to be circulatory disorder in acute death and renal injury in delayed death. The renal injury was observed in the 300 and 600 mg/kg groups. In the 2-week repeated dose study, BSH was administered at doses of 30, 100 or 300 mg/kg/day for 14 days. Body weight gain was suppressed in the 100 and 300 mg/kg groups. One male in the 300 mg/kg group died due to renal and pulmonary lesions at day 8. Slight anemia was observed in the 300 mg/kg group. Pathologically, the kidney showed tubular regeneration with increase of weight in the 300 mg/kg. From these results, the NOAEL of BSH is 30 mg/kg/day. (author)

  20. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Science.gov (United States)

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J

    2016-01-01

    Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max

  1. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Directory of Open Access Journals (Sweden)

    Oliver Stoller

    Full Text Available Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC. The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations.Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error. Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC, standard error of the measurement (SEM, and minimal detectable change (MDC. Mean differences, limits of agreement, and coefficients of variation (CoV were estimated to assess repeatability.All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects. Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%. Repeatability for the primary outcomes was good (CoV ≤ 0.12.RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2

  2. A high stability and repeatability electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-12-01

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  3. Flanking Variation Influences Rates of Stutter in Simple Repeats

    Directory of Open Access Journals (Sweden)

    August E. Woerner

    2017-11-01

    Full Text Available It has been posited that the longest uninterrupted stretch (LUS of tandem repeats, as defined by the number of exactly matching repeating motif units, is a better predictor of rates of stutter than the parental allele length (PAL. While there are cases where this hypothesis is likely correct, such as the 9.3 allele in the TH01 locus, there can be situations where it may not apply as well. For example, the PAL may capture flanking indel variations while remaining insensitive to polymorphisms in the repeat, and these haplotypic changes may impact the stutter rate. To address this, rates of stutter were contrasted against the LUS as well as the PAL on different flanking haplotypic backgrounds. This study shows that rates of stutter can vary substantially depending on the flanking haplotype, and while there are cases where the LUS is a better predictor of stutter than the PAL, examples to the contrary are apparent in commonly assayed forensic markers. Further, flanking variation that is 7 bp from the repeat region can impact rates of stutter. These findings suggest that non-proximal effects, such as DNA secondary structure, may be impacting the rates of stutter in common forensic short tandem repeat markers.

  4. "Focused introspection" during naturally increased diuresis: description and repeatability of a method to study bladder sensation non-invasively.

    Science.gov (United States)

    De Wachter, Stefan G G; Heeringa, Rhea; Van Koeveringe, Gommert A; Winkens, Bjorn; Van Kerrebroeck, Philip E V; Gillespie, James I

    2014-06-01

    To present and describe a non-invasive method to study the origin and development of bladder filling sensation and to evaluate the repeatability of the method. Eighteen volunteers participated in the study and were given a water loading protocol consisting of 1,000 ml water intake 1 hr before the session and 200 ml every 10 min during the session. Protocol 1: To evaluate diuresis rate, seven participants were asked to void every 15 min and the voided volume was measured. Protocol 2: Eleven volunteers graded bladder sensation on regular time points, on an empty graph with time on the X-axis and intensity of sensation on the Y-axis. The protocol ended at absolute need to void (maximal intensity) and voided volumes were measured. This protocol was conducted three times with a 10 days interval. Protocol 1: The diuresis rate was not different during the sessions and showed no variation over the studied time period (P = 0.2). Protocol 2: For an individual, the diuresis rate was not different between the sessions. The curves in all patients showed a continuously increasing bladder intensity. In seven participants the curve was convex, in the other four, the curve was sigmoidal. For each individual the pattern was constant during the three sessions. A strict water loading protocol induces a constant diuresis. This allows individuals to draw an introspection bladder sensation curve with a specific shape, which can be used as a method to study the development of bladder sensation non-invasively. © 2013 Wiley Periodicals, Inc.

  5. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  6. A probit- log- skew-normal mixture model for repeated measures data with excess zeros, with application to a cohort study of paediatric respiratory symptoms

    Directory of Open Access Journals (Sweden)

    Johnston Neil W

    2010-06-01

    Full Text Available Abstract Background A zero-inflated continuous outcome is characterized by occurrence of "excess" zeros that more than a single distribution can explain, with the positive observations forming a skewed distribution. Mixture models are employed for regression analysis of zero-inflated data. Moreover, for repeated measures zero-inflated data the clustering structure should also be modeled for an adequate analysis. Methods Diary of Asthma and Viral Infections Study (DAVIS was a one year (2004 cohort study conducted at McMaster University to monitor viral infection and respiratory symptoms in children aged 5-11 years with and without asthma. Respiratory symptoms were recorded daily using either an Internet or paper-based diary. Changes in symptoms were assessed by study staff and led to collection of nasal fluid specimens for virological testing. The study objectives included investigating the response of respiratory symptoms to respiratory viral infection in children with and without asthma over a one year period. Due to sparse data daily respiratory symptom scores were aggregated into weekly average scores. More than 70% of the weekly average scores were zero, with the positive scores forming a skewed distribution. We propose a random effects probit/log-skew-normal mixture model to analyze the DAVIS data. The model parameters were estimated using a maximum marginal likelihood approach. A simulation study was conducted to assess the performance of the proposed mixture model if the underlying distribution of the positive response is different from log-skew normal. Results Viral infection status was highly significant in both probit and log-skew normal model components respectively. The probability of being symptom free was much lower for the week a child was viral positive relative to the week she/he was viral negative. The severity of the symptoms was also greater for the week a child was viral positive. The probability of being symptom free was

  7. The effect of sex on the repeatability of evolution in different environments.

    Science.gov (United States)

    Lachapelle, Josianne; Colegrave, Nick

    2017-04-01

    The adaptive function of sex has been extensively studied, while less consideration has been given to the potential downstream consequences of sex on evolution. Here, we investigate one such potential consequence, the effect of sex on the repeatability of evolution. By affecting the repeatability of evolution, sex could have important implications for biodiversity, and for our ability to make predictions about the outcome of environmental change. We allowed asexual and sexual populations of Chlamydomonas reinhardtii to evolve in novel environments and monitored both their change in fitness and variance in fitness after evolution. Sex affected the repeatability of evolution by changing the importance of the effect of selection, chance, and ancestral constraints on the outcome of the evolutionary process. In particular, the effects of sex were highly dependent on the initial genetic composition of the population and on the environment. Given the lack of a consistent effect of sex on repeatability across the environments used here, further studies to dissect in more detail the underlying reasons for these differences as well as studies in additional environments are required if we are to have a general understanding of the effects of sex on the repeatability of evolution. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  8. Preservice science teachers' experiences with repeated, guided inquiry

    Science.gov (United States)

    Slack, Amy B.

    The purpose of this study was to examine preservice science teachers' experiences with repeated scientific inquiry (SI) activities. The National Science Education Standards (National Research Council, 1996) stress students should understand and possess the abilities to do SI. For students to meet these standards, science teachers must understand and be able to perform SI; however, previous research demonstrated that many teachers have naive understandings in this area. Teacher preparation programs provide an opportunity to facilitate the development of inquiry understandings and abilities. In this study, preservice science teachers had experiences with two inquiry activities that were repeated three times each. The research questions for this study were (a) How do preservice science teachers' describe their experiences with repeated, guided inquiry activities? (b) What are preservice science teachers' understandings and abilities of SI? This study was conducted at a large, urban university in the southeastern United States. The 5 participants had bachelor's degrees in science and were enrolled in a graduate science education methods course. The researcher was one of the course instructors but did not lead the activities. Case study methodology was used. Data was collected from a demographic survey, an open-ended questionnaire with follow-up interviews, the researcher's observations, participants' lab notes, personal interviews, and participants' journals. Data were coded and analyzed through chronological data matrices to identify patterns in participants' experiences. The five domains identified in this study were understandings of SI, abilities to conduct SI, personal feelings about the experience, science content knowledge, and classroom implications. Through analysis of themes identified within each domain, the four conclusions made about these preservice teachers' experiences with SI were that the experience increased their abilities to conduct inquiry

  9. Hybrid FRC under repeated loading

    International Nuclear Information System (INIS)

    Komlos, K.; Babal, B.; Nuernbergerova, T.

    1993-01-01

    Fibre reinforced concretes (FRC) containing several volume fractions in different ratios of two types of fibres - polypropylene and steel, were tested under repeated loading. Mechanical properties of specimens - cubes 150/150/150 mm (for compressive strength), prisms 100/100/400 (for flexural strength), short cylinders 150/60 mm (for impact strength) have been experimentally investigated before and after cyclic loading at the age of 28 days curing time. Mix proportions were designed after DIN 1045 with max. aggregate size 8 mm and grading curve B 8. Portland Cement PC 400 in the amount of 450 kg. m -3 was applied and W/C ratio 0.55. Workability of mixes was measured by Vebe method and regulated by plasticizing admixture Ligoplast Na. Maximum hybrid fibre volume fraction (polypropylene + steel) was 1.0%. Dynamic forces generated in Schenck testing machine with frequency 16 Hz had sinusoidal wave form varying between 0.7 and 0.1 of static mechanical characteristics. The number of cycles in all tests was 10 5 . The residual MOR at static four point bending test and working diagram force-deflection was carried out as well. The impact properties after repeated loading in compression were tested by means of falling weight test. Relationships between composition of fibre composites with different combination of polypropylene (0.2, 0.3, 0.5% by volume) and steel (0.5, 0.7, and 0.8% by volume) fibre content were obtained and technological properties of mixes as well. (author)

  10. Test-retest repeatability of strength capacity, aerobic power and pericranial tenderness of neck and shoulder muscles in children - relevant for tension-type headache

    DEFF Research Database (Denmark)

    Tornøe, Birte; Andersen, Lars L; Skotte, J H

    2013-01-01

    Frequent or chronic tension-type headache in children is a prevalent and debilitating condition for the child, often leading to medication overuse. To explore the relationship between physical factors and tension-type headache in children, the quality of repeated measures was examined. The aim of...... of the present study was to determine the test-retest repeatability of parameters determining isometric neck and shoulder strength and stability, aerobic power, and pericranial tenderness in children....

  11. Study of the repeatability of histone genes in the ploidy series of wheat and Aegilops

    International Nuclear Information System (INIS)

    Vakhitov, V.A.; Kulikov, A.M.

    1986-01-01

    The hDNA content and number of histone genes in the genomes of different wheat and Aegilops species have been determined by molecular hybridization of DNA with 125 I-histone DNA of Drosophila (L-repeat) on nitrocellulose filters. It has been demonstrated that the proportion of hDNA in the total DNA of diploid and polyploid wheat species is (1.3-7.7) x 10 -3 % (57-850 genes), and in the ploidy series of Aegilops species (2.0-8.0) x 10 -3 % (89-780 genes). The repeatability of the histone genes generally increases at each ploidy level in the species with higher DNA content. At the same time, it has been demonstrated that the DNA content is not the only factor determining repeatability of the histone genes, as some diploid and allopolyploid species have similar number of these genes. It has been concluded that genetic mechanisms are involved in the regulation of the number of histone genes

  12. Use of Different Furnaces to Study Repeatability and Reproducibility of Three Pd-C Cells

    Science.gov (United States)

    Battuello, M.; Florio, M.; Girard, F.

    2010-09-01

    Three different Pd-C eutectic fixed-point cells were prepared and investigated at INRIM. Several tens of phase transition runs were carried out and recorded with both a Si-based radiation thermometer at 950 nm and a precision InGaAs-based thermometer at 1.6 μm. Two of the cells were of the same design with an inner volume of 12 cm3. The third one was smaller with a useful inner volume of 3.6 cm3. The three cells were filled with palladium powder 4N5 or 4N8 pure and graphite powder 6N pure. The repeatability and stability of the inflection point were investigated over a period of 1 year. The noticeably different external dimensions of the two cells, namely, 110 mm and 40 mm in length, allowed the influence of the longitudinal temperature distribution to be investigated. For this purpose, two different furnaces, a single-zone with SiC heaters and a three-zone with MoSi2 heaters, were used. Different operative conditions, namely, temperature steps, melting rate, longitudinal temperature distributions, and position of cells within the furnace, were tested to investigate the reproducibility of the cells. Effects on the duration and shape of the plateaux were also studied. This article gives details of the measurement setup and analyses of the melting plateaux obtained with the different conditions.

  13. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  14. Minocycline Prevents Muscular Pain Hypersensitivity and Cutaneous Allodynia Produced by Repeated Intramuscular Injections of Hypertonic Saline in Healthy Human Participants.

    Science.gov (United States)

    Samour, Mohamad Samir; Nagi, Saad Saulat; Shortland, Peter John; Mahns, David Anthony

    2017-08-01

    Minocycline, a glial suppressor, prevents behavioral hypersensitivities in animal models of peripheral nerve injury. However, clinical trials of minocycline in human studies have produced mixed results. This study addressed 2 questions: can repeated injections of hypertonic saline (HS) in humans induce persistent hypersensitivity? Can pretreatment with minocycline, a tetracycline antibiotic with microglial inhibitory effects, prevent the onset of hypersensitivity? Twenty-seven healthy participants took part in this double-blind, placebo-controlled study, consisting of 6 test sessions across 2 weeks. At the beginning of every session, pressure-pain thresholds of the anterior muscle compartment of both legs were measured to determine the region distribution and intensity of muscle soreness. To measure changes in thermal sensitivity in the skin overlying the anterior muscle compartment of both legs, quantitative sensory testing was used to measure the cutaneous thermal thresholds (cold sensation, cold pain, warm sensation, and heat pain) and a mild cooling stimulus was applied to assess the presence of cold allodynia. To induce ongoing hypersensitivity, repeated injections of HS were administered into the right tibialis anterior muscle at 48-hour intervals. In the final 2 sessions (days 9 and 14), only sensory assessments were done to plot the recovery after cessation of HS administrations and drug washout. By day 9, nontreated participants experienced a significant bilateral increase in muscle soreness (P minocycline-treated participants experienced a bilateral 70% alleviation in muscle soreness (P minocycline-treated participants showed cold allodynia. This study showed that repeated injections of HS can induce a hypersensitivity that outlasts the acute response, and the development of this hypersensitivity can be reliably attenuated with minocycline pretreatment. Four repeated injections of HS at 48-hour intervals induce a state of persistent hypersensitivity in

  15. Establishing column batch repeatability according to Quality by Design (QbD) principles using modeling software.

    Science.gov (United States)

    Rácz, Norbert; Kormány, Róbert; Fekete, Jenő; Molnár, Imre

    2015-04-10

    Column technology needs further improvement even today. To get information of batch-to-batch repeatability, intelligent modeling software was applied. Twelve columns from the same production process, but from different batches were compared in this work. In this paper, the retention parameters of these columns with real life sample solutes were studied. The following parameters were selected for measurements: gradient time, temperature and pH. Based on calculated results, batch-to-batch repeatability of BEH columns was evaluated. Two parallel measurements on two columns from the same batch were performed to obtain information about the quality of packing. Calculating the average of individual working points at the highest critical resolution (R(s,crit)) it was found that the robustness, calculated with a newly released robustness module, had a success rate >98% among the predicted 3(6) = 729 experiments for all 12 columns. With the help of retention modeling all substances could be separated independently from the batch and/or packing, using the same conditions, having high robustness of the experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Dynamic Pain Phenotypes are Associated with Spinal Cord Stimulation-Induced Reduction in Pain: A Repeated Measures Observational Pilot Study.

    Science.gov (United States)

    Campbell, Claudia M; Buenaver, Luis F; Raja, Srinivasa N; Kiley, Kasey B; Swedberg, Lauren J; Wacnik, Paul W; Cohen, Steven P; Erdek, Michael A; Williams, Kayode A; Christo, Paul J

    2015-07-01

    Spinal cord stimulation (SCS) has become a widely used treatment option for a variety of pain conditions. Substantial variability exists in the degree of benefit obtained from SCS and patient selection is a topic of expanding interest and importance. However, few studies have examined the potential benefits of dynamic quantitative sensory testing (QST) to develop objective measures of SCS outcomes or as a predictive tool to help patient selection. Psychological characteristics have been shown to play an important role in shaping individual differences in the pain experience and may aid in predicting responses to SCS. Static laboratory pain-induction measures have also been examined in their capacity for predicting SCS outcomes. The current study evaluated clinical, psychological and laboratory pain measures at baseline, during trial SCS lead placement, as well as 1 month and 3 months following permanent SCS implantation in chronic pain patients who received SCS treatment. Several QST measures were conducted, with specific focus on examination of dynamic models (central sensitization and conditioned pain modulation [CPM]) and their association with pain outcomes 3 months post SCS implantation. Results suggest few changes in QST over time. However, central sensitization and CPM at baseline were significantly associated with clinical pain at 3 months following SCS implantation, controlling for psycho/behavioral factors and pain at baseline. Specifically, enhanced central sensitization and reduced CPM were associated with less self-reported pain 3 months following SCS implantation. These findings suggest a potentially important role for dynamic pain assessment in individuals undergoing SCS, and hint at potential mechanisms through which SCS may impart its benefit. Wiley Periodicals, Inc.

  17. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    Science.gov (United States)

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  18. Device-independent secret-key-rate analysis for quantum repeaters

    Science.gov (United States)

    Holz, Timo; Kampermann, Hermann; Bruß, Dagmar

    2018-01-01

    The device-independent approach to quantum key distribution (QKD) aims to establish a secret key between two or more parties with untrusted devices, potentially under full control of a quantum adversary. The performance of a QKD protocol can be quantified by the secret key rate, which can be lower bounded via the violation of an appropriate Bell inequality in a setup with untrusted devices. We study secret key rates in the device-independent scenario for different quantum repeater setups and compare them to their device-dependent analogon. The quantum repeater setups under consideration are the original protocol by Briegel et al. [Phys. Rev. Lett. 81, 5932 (1998), 10.1103/PhysRevLett.81.5932] and the hybrid quantum repeater protocol by van Loock et al. [Phys. Rev. Lett. 96, 240501 (2006), 10.1103/PhysRevLett.96.240501]. For a given repeater scheme and a given QKD protocol, the secret key rate depends on a variety of parameters, such as the gate quality or the detector efficiency. We systematically analyze the impact of these parameters and suggest optimized strategies.

  19. Analysis of the Effect of Radio Frequency Interference on Repeat Track Airborne InSAR System

    Directory of Open Access Journals (Sweden)

    Ding Bin

    2012-03-01

    Full Text Available The SAR system operating at low frequency is susceptible to Radio Frequency Interference (RFI from television station, radio station, and some other civil electronic facilities. The presence of RFI degrades the SAR image quality, and obscures the targets in the scene. Furthermore, RFI can cause interferometric phase error in repeat track InSAR system. In order to analyze the effect of RFI on interferometric phase of InSAR, real measured RFI signal are added on cone simulated SAR echoes. The imaging and interferometric processing results of both the RFI-contaminated and raw data are given. The effect of real measured RFI signal on repeat track InSAR system is analyzed. Finally, the imaging and interferometric processing results of both with and without RFI suppressed of the P band airborne repeat track InSAR real data are presented, which demonstrates the efficiency of the RFI suppression method in terms of decreasing the interferometric phase errors caused by RFI.

  20. The Vestibular Effects of Repeated Low-Level Blasts.

    Science.gov (United States)

    Littlefield, Philip D; Pinto, Robin L; Burrows, Holly L; Brungart, Douglas S

    2016-01-01

    The objective of this study was to use a prospective cohort of United States Marine Corps (USMC) instructors to identify any acute or long-term vestibular dysfunction following repeated blast exposures during explosive breaching training. They were assessed in clinic and on location during training at the USMC Methods of Entry School, Quantico, VA. Subjects received comprehensive baseline vestibular assessments and these were repeated in order to identify longitudinal changes. They also received shorter assessments immediately following blast exposure in order to identify acute findings. The main outcome measures were the Neurobehavioral Symptom Inventory, vestibular Visual Analog Scale (VAS) of subjective vestibular function, videonystagmography (VNG), vestibular evoked myogenic potentials (VEMP), rotary chair (including the unilateral centrifugation test), computerized dynamic posturography, and computerized dynamic visual acuity. A total of 11 breachers and 4 engineers were followed for up to 17 months. No acute effects or longitudinal deteriorations were identified, but there were some interesting baseline group differences. Upbeat positional nystagmus was common, and correlated (p<0.005) with a history of mild traumatic brain injury (mTBI). Several instructors had abnormally short low-frequency phase leads on rotary chair testing. This study evaluated breaching instructors over a longer test period than any other study, and the results suggest that this population appears to be safe from a vestibular standpoint at the current exposure levels. Upbeat positional nystagmus correlated with a history of mTBI in this population, and this has not been described elsewhere. The data trends also suggest that this nystagmus could be an acute blast effect. However, the reasons for the abnormally short phase leads seen in rotary chair testing are unclear at this time. Further investigation seems warranted.

  1. One way quantum repeaters with quantum Reed-Solomon codes

    OpenAIRE

    Muralidharan, Sreraman; Zou, Chang-Ling; Li, Linshu; Jiang, Liang

    2018-01-01

    We show that quantum Reed-Solomon codes constructed from classical Reed-Solomon codes can approach the capacity on the quantum erasure channel of $d$-level systems for large dimension $d$. We study the performance of one-way quantum repeaters with these codes and obtain a significant improvement in key generation rate compared to previously investigated encoding schemes with quantum parity codes and quantum polynomial codes. We also compare the three generation of quantum repeaters using quan...

  2. Scoliosis short-term rehabilitation (SSTR according to 'Best Practice' standards - are the results repeatable?

    Directory of Open Access Journals (Sweden)

    Borysov Maksym

    2012-01-01

    Full Text Available Abstract Claims have been made in a pilot study that a new form of short-term rehabilitation according to 'Best Practice' standards would change signs and symptoms of patients with scoliosis in the short-term. Aim of this study is to repeat the study published 2010 with a larger sample of patients using the same protocol. Both authors have undergone training in this special approach to scoliosis rehabilitation in 2010. Materials and methods 34 patients with Adolescent Idiopathic Scoliosis (AIS, 32 girls and 2 boys, average age 13.7 years and an average Cobb angle of 28.7 degrees (21-43 degrees underwent Scoliosis Short-Term Rehabilitation (SSTR of seven days. Two days with an intensity of 3 × 90 min sessions/day, and five days with an intensity of 2 × 60 min sessions/day. Angle of trunk rotation (ATR was measured before and after the time of treatment as well as the active correctability of the ATR after the programme as it has been done in the pilot investigation. Additionally to that, we also recorded the changes in Vital Capacity (VC before and after the programme. Results ATR was reduced significantly from 11,5 degrees to 8,4 degrees, the active correctability as measured with the Scoliometer (TM was also reduced significantly from the ATR after treatment 8,9 degrees to 6,5 degrees in the patients with thoracic curves. VC improved significantly (P Discussion The results achieved in the pilot investigation published previously are repeatable. The deformity of the trunk can be reduced significantly after SSTR. During the pilot study VC was not investigated. In our study VC improved significantly. Therefore, also shorter rehabilitation times with an appropriate programme seem to be able to change signs and symptoms of a patient with scoliosis. Like the out-patient Schroth programme as described in a study from Turkey, the SSTR provides benefits leading to an improvement of the condition. Conclusion Out-patient rehabilitation following the

  3. Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST

    Directory of Open Access Journals (Sweden)

    Bernardo T. Lopes

    2017-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of dynamic corneal response parameters measured by the Corvis ST (Oculus, Wetzlar, Germany. Methods. One eye randomly selected from 32 healthy volunteers was examined by the Corvis ST. Three different devices were used in an alternated random order for taking three measurements at each device in each subject. Standard intraocular pressure (IOP, the biomechanical-compensated IOP (bIOP, and DCR parameters were evaluated. The within-subject standard deviation (ζw and coefficient of variation (CV were assessed. Results. Regarding pressure indices, the ζw was below 1 mmHg for repeatability (0.98 for IOP and 0.89 for bIOP and the CV was 6.6% for IOP and 6.1% for bIOP. For reproducibility, the ζw was around 1 mmHg (1.12 for IOP and 1.05 for bIOP and the CV was 7.6% for IOP and 7.1% for bIOP. Most of DCR indices presented CV for repeatability below 4%. For reproducibility, the CV of most of the indices were below 6%. The deformation amplitude (DA ratio in 1 mm and integrated radius were below 4% (1.2% and 3.8%, resp.. Conclusions. The Corvis ST showed good precision (repeatability and reproducibility for IOP measurements and for DCR in healthy eyes.

  4. Genus-specific protein binding to the large clusters of DNA repeats (short regularly spaced repeats) present in Sulfolobus genomes

    DEFF Research Database (Denmark)

    Peng, Xu; Brügger, Kim; Shen, Biao

    2003-01-01

    terminally modified and corresponds to SSO454, an open reading frame of previously unassigned function. It binds specifically to DNA fragments carrying double and single repeat sequences, binding on one side of the repeat structure, and producing an opening of the opposite side of the DNA structure. It also...... recognizes both main families of repeat sequences in S. solfataricus. The recombinant protein, expressed in Escherichia coli, showed the same binding properties to the SRSR repeat as the native one. The SSO454 protein exhibits a tripartite internal repeat structure which yields a good sequence match...... with a helix-turn-helix DNA-binding motif. Although this putative motif is shared by other archaeal proteins, orthologs of SSO454 were only detected in species within the Sulfolobus genus and in the closely related Acidianus genus. We infer that the genus-specific protein induces an opening of the structure...

  5. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    Science.gov (United States)

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  6. Coexistence of 3G repeaters with LTE base stations.

    Science.gov (United States)

    Yeo, Woon-Young; Lee, Sang-Min; Hwang, Gyung-Ho; Kim, Jae-Hoon

    2013-01-01

    Repeaters have been an attractive solution for mobile operators to upgrade their wireless networks at low cost and to extend network coverage effectively. Since the first LTE commercial deployment in 2009, many mobile operators have launched LTE networks by upgrading their 3G and legacy networks. Because all 3G frequency bands are shared with the frequency bands for LTE deployment and 3G mobile operators have an enormous number of repeaters, reusing 3G repeaters in LTE networks is definitely a practical and cost-efficient solution. However, 3G repeaters usually do not support spatial multiplexing with multiple antennas, and thus it is difficult to reuse them directly in LTE networks. In order to support spatial multiplexing of LTE, the role of 3G repeaters should be replaced with small LTE base stations or MIMO-capable repeaters. In this paper, a repeater network is proposed to reuse 3G repeaters in LTE deployment while still supporting multilayer transmission of LTE. Interestingly, the proposed network has a higher cluster throughput than an LTE network with MIMO-capable repeaters.

  7. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan

    2010-12-15

    SIGMOD 2008 was the first database conference that offered to test submitters\\' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  8. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan; Manolescu, Ioana; Afanasiev, Loredana; Feng, Jieling; Gou, G.; Hadjieleftheriou, Marios; Harizopoulos, Stavros; Kalnis, Panos; Karanasos, Konstantinos; Laurent, Dominique; Lupu, M.; Onose, N.; Ré , C.; Sans, Virginie; Senellart, Pierre; Wu, T.; Shasha, Dennis E.

    2010-01-01

    SIGMOD 2008 was the first database conference that offered to test submitters' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  9. FRB 121102: A Starquake-induced Repeater?

    Science.gov (United States)

    Wang, Weiyang; Luo, Rui; Yue, Han; Chen, Xuelei; Lee, Kejia; Xu, Renxin

    2018-01-01

    Since its initial discovery, the fast radio burst (FRB) FRB 121102 has been found to be repeating with millisecond-duration pulses. Very recently, 14 new bursts were detected by the Green Bank Telescope during its continuous monitoring observations. In this paper, we show that the burst energy distribution has a power-law form which is very similar to the Gutenberg–Richter law of earthquakes. In addition, the distribution of burst waiting time can be described as a Poissonian or Gaussian distribution, which is consistent with earthquakes, while the aftershock sequence exhibits some local correlations. These findings suggest that the repeating FRB pulses may originate from the starquakes of a pulsar. Noting that the soft gamma-ray repeaters (SGRs) also exhibit such distributions, the FRB could be powered by some starquake mechanisms associated with the SGRs, including the crustal activity of a magnetar or solidification-induced stress of a newborn strangeon star. These conjectures could be tested with more repeating samples.

  10. Comparing Destination Image and Loyalty between First-time and Repeat-visit Tourists

    Directory of Open Access Journals (Sweden)

    Mohamad M.

    2014-01-01

    Full Text Available The objective of this study was to investigate the difference between destination image and loyalty among first-time and repeat-visit tourists. The study was undertaken to examine aspects of underlying factors of destination image that influenced tourists’ willingness to recommend Malaysia to their friends and relatives as well as spread positive word-of-mouth to others. In addition, it was to ascertain the relationship between destination image and loyalty among first-time and repeat-visit tourists. The data was collected at Kuala Lumpur International Airport at the departure hall using self-administered questionnaires. 248 usable questionnaires were returned and analysed. The findings of the study revealed that both groups of tourists perceived Malaysia as providing a nature-based destination. The study also empirically proved that both first-time and repeat-visit tourists were willing to disseminate positive word-of-mouth and recommend Malaysia to their friends and relatives as a vacation destination to visit. However, there was a significant difference in destination loyalty between first-visit and repeat-visit tourists.

  11. Multielemental segregation analysis of the thallium bromide impurities purified by repeated Bridgman technique

    International Nuclear Information System (INIS)

    Santos, Robinson A. dos; Hamada, Margarida M.; Costa, Fabio E. da; Gennari, Roseli F.; Martins, Joao F.T.; Marcondes, Renata M.; Mesquita, Carlos H. de

    2011-01-01

    TlBr crystals were purified and grown by the repeated Bridgman method from two commercial TlBr salts and characterized to be used as radiation detectors. To evaluate the purification efficiency, measurements of the impurity concentration were made after each growth, analyzing the trace impurities by inductively coupled plasma mass spectroscopy (ICP-MS). A significant decrease of the impurity concentration resulting from the purification number was observed. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out. The radiation response depended on the crystal purity. The repeated Bridgman technique improved the TlBr crystal quality used as a radiation detector. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growth. (author)

  12. A high stability and repeatability electrochemical scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Zhigang; Wang, Jihao; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-12-15

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO{sub 4}{sup 2−} image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  13. On the crustal bias of repeat stations in Romania

    Directory of Open Access Journals (Sweden)

    Venera Dobrica

    2013-03-01

    Full Text Available A magnetic induction model has been applied to recordings obtained in 2010 during the field campaigns for geomagnetic measurements at the 26 repeat stations of the Romanian secular variation network. The model is based on the observation that a variable external magnetic field induces a response of the Earth's interior not only by electromagnetic induction, but also by magnetic induction in the magnetic rocks above the Curie temperature. The model computes coefficients of a linear relationship between recorded values of a certain geomagnetic element (X, Y, Z, or F at the repeat station and recorded X, Y, Z values at a reference station (in this case, SUA observatory. Coefficients depend on magnetic permeabilities of rocks beneath the station and stand as a proxy for the anomaly bias characterizing the site. Maps of the lateral variation of this type of information were obtained and discussed.

  14. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  15. Effects of repeated firing on the marginal accuracy of Co-Cr copings fabricated by selective laser melting.

    Science.gov (United States)

    Zeng, Li; Zhang, Yong; Liu, Zheng; Wei, Bin

    2015-02-01

    Selective laser melting (SLM) is a technique used to fabricate Co-Cr dental restorations; however, because marginal accuracy is important for the long-term success of restorations, the marginal accuracy of SLM after repeated firings must be considered. The purpose of this study was to evaluate the marginal accuracy of dental Co-Cr alloy copings fabricated by SLM and to investigate the effects of repeated firing on the marginal fit of these copings. SLM-fabricated and cast Co-Cr alloy copings (n=15) were prepared for a zirconia die. The marginal gap widths of each group were evaluated with a silicone replica technique after the first, third, fifth, and seventh firing cycle. The thickness of the reference point was measured with a stereomicroscope with ×100 magnification. Analysis of variance was used to evaluate the effect of repeated firing on the marginal accuracy of the 2 alloys. The Student t test was used to compare the marginal gap widths of the SLM-fabricated and cast Co-Cr alloy copings after repeated firing (α=.05). The marginal gap width values between the 2 groups at all firing periods were statistically significant (P.05). The SLM copings demonstrated superior marginal accuracy at all firings. Repeated firing had no significant influence on the marginal accuracy of both copings, and the marginal fit of both copings after repeated firing was within a clinically acceptable range. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Construction of a quantum repeater with linear optics

    International Nuclear Information System (INIS)

    Kok, Pieter; Williams, Colin P.; Dowling, Jonathan P.

    2003-01-01

    We study the mechanism and complexity of an efficient quantum repeater, employing double-photon guns, for long-distance optical quantum communication. The guns create polarization-entangled photon pairs on demand. One such source might be a semiconducter quantum dot, which has the distinct advantage over parametric down-conversion that the probability of creating a photon pair is close to 1, while the probability of creating multiple pairs vanishes. The swapping and purifying components are implemented by polarizing beam splitters and probabilistic optical controlled-NOT gates. We also show that the bottleneck in the efficiency of this repeater is due to detector losses

  17. A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Lee A.; Dixon, Adrian K. (Dept. of Radiology, Cambridge Univ. Teaching Hospitals NHS Foundation Trust, Cambridge (United Kingdom)), e-mail: leegrant100@gmail.com; Napolitano, Antonella; McHugh, Simon M. (GlaxoSmithKline RandD, Clinical Unit Cambridge, Addenbrooke' s Centre for Clinical Investigation, Addenbrooke' s Hospital, Cambridge (United Kingdom)); Miller, Sam (Analysis Applications Research Group, GSK RandD, Harlow, Essex (United Kingdom)); Stephens, Kimberley (Discovery Statistics, GSK RandD, Harlow, Essex (United Kingdom))

    2010-01-15

    Background: Repeated computed tomography (CT) assessment of the adrenal glands is associated with a significant radiation burden. The increasing capabilities of magnetic resonance (MR) volumetric analysis of the adrenals make this a potentially alternative technique in man. Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm3 adrenal gland. Interobserver variation is approximately 9% of a 3-cm3 adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm3 adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size

  18. Repeated wildfires alter forest recovery of mixed-conifer ecosystems.

    Science.gov (United States)

    Stevens-Rumann, Camille; Morgan, Penelope

    2016-09-01

    Most models project warmer and drier climates that will contribute to larger and more frequent wildfires. However, it remains unknown how repeated wildfires alter post-fire successional patterns and forest structure. Here, we test the hypothesis that the number of wildfires, as well as the order and severity of wildfire events interact to alter forest structure and vegetation recovery and implications for vegetation management. In 2014, we examined forest structure, composition, and tree regeneration in stands that burned 1-18 yr before a subsequent 2007 wildfire. Three important findings emerged: (1) Repeatedly burned forests had 15% less woody surface fuels and 31% lower tree seedling densities compared with forests that only experienced one recent wildfire. These repeatedly burned areas are recovering differently than sites burned once, which may lead to alternative ecosystem structure. (2) Order of burn severity (high followed by low severity compared with low followed by high severity) did influence forest characteristics. When low burn severity followed high, forests had 60% lower canopy closure and total basal area with 92% fewer tree seedlings than when high burn severity followed low. (3) Time between fires had no effect on most variables measured following the second fire except large woody fuels, canopy closure and tree seedling density. We conclude that repeatedly burned areas meet many vegetation management objectives of reduced fuel loads and moderate tree seedling densities. These differences in forest structure, composition, and tree regeneration have implications not only for the trajectories of these forests, but may reduce fire intensity and burn severity of subsequent wildfires and may be used in conjunction with future fire suppression tactics. © 2016 by the Ecological Society of America.

  19. Inter-Simple Sequence Repeat (ISSR Markers to Study Genetic Diversity Among Cotton Cultivars in Associated with Salt Tolerance

    Directory of Open Access Journals (Sweden)

    Ali Akbar ABDI

    2012-11-01

    Full Text Available Developing salt-tolerant crops is very important as a significant proportion of cultivated land is salt-affected. Screening and selection of salt tolerant genotypes of cotton using DNA molecular markers not only introduce tolerant cultivars useful for hybridization and breeding programs but also detect DNA regions involved in mechanism of salinity tolerance. To study this, 28 cotton cultivars, including 8 Iranian cotton varieties were grown in pots under greenhouse condition and three salt treatments were imposed with salt solutions (0, 70 and 140 mM NaCl. Eight agronomic traits including root length, root fresh weight, root dry weight, chlorophyll and fluorescence index, K+ and Na+ contents in shoot (above ground biomass, and K+/Na+ ratio were measured. Cluster analysis of cultivars based on measured agronomic traits, showed �Cindose� and �Ciacra� as the most tolerant cultivars, and �B-557� and �43347� as the most sensitive cultivars of salt damage. A total of 65 polymorphic DNA fragments were generated at 14 inter-simple sequence repeat (ISSR loci. Plants of 28 cultivars of cotton grouped into three clusters based on ISSR markers. Regression analysis of markers in relation with traits data showed that 23, 33 and 30 markers associated with the measured traits in three salt treatments respectively. These markers might help breeders in any marker assisted selection program in order to improving cotton cultivars against salt stress.

  20. Ground measured evapotranspiration scaled to stand level using MODIS and Landsat sensors to study Tamarix spp.response to repeated defoliation by the Tamarix leaf beetle at two sites

    Science.gov (United States)

    Pearlstein, S.; Nagler, P. L.; Glenn, E. P.; Hultine, K. R.

    2012-12-01

    The Dolores River in Southern Utah and the Virgin River in Southern Nevada are ecosystems under pressure from increased groundwater withdrawal due to growing populations and introduced riparian species. We studied the impact of the biocontrol Tamarix leaf beetles (Dirohabda carinulata and D. elongata) on the introduced riparian species, Tamarix spp., phenology and water use over multiple cycles of annual defoliation. Heat balance sap flow measurements, leaf area index (LAI), well data, allometry and satellite imagery from Landsat Thematic Mapper 5 and EOS-1 Moderate Resolution Imaging Spectrometer (MODIS) sensors were used to assess the distribution of beetle defoliation and its effect on evapotranspiration (ET). Study objectives for the Virgin River were to measure pre-beetle arrival ET, while the Dolores River site has had defoliation since 2004 and is a site of long-term beetle effect monitoring. This study focuses on measurements conducted over two seasons, 2010 and 2011. At the Dolores River site, results from 2010 were inconclusive due to sensor malfunctions but plant ET by sap flow in 2011 averaged 1.02 mm/m^2 leaf area/day before beetle arrival, dropping to an average of 0.75 mm/m^2 leaf area/day after beetle arrival. Stand level estimations from May - December, 2010 by MODIS were about 0.63 mm/ day, results from Landsat were 0.51 mm/day in June and 0.78 in August. For January -September, 2011, MODIS values were about 0.6 mm/day, and Landsat was 0.57 mm/day in June and 0.62 mm/day in August. These values are lower than previously reported ET values for this site meaning that repeated defoliation does diminish stand level water use. The Virgin River site showed plant ET from sap flow averaged about 3.9-4 mm/m^2 leaf area/day from mid-May - September, 2010. In 2011, ET from sap flow averaged 3.83 mm/m^2 leaf area/day during June - July, but dropped to 3.73 mm/ m^2 leaf area/day after beetle arrival in August. The slight drop in plant ET is not significant

  1. Chromosome-specific DNA Repeat Probes

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, Adolf; Weier, Jingly Fung; Weier, Heinz-Ulrich G.

    2006-03-16

    In research as well as in clinical applications, fluorescence in situ hybridization (FISH) has gained increasing popularity as a highly sensitive technique to study cytogenetic changes. Today, hundreds of commercially available DNA probes serve the basic needs of the biomedical research community. Widespread applications, however, are often limited by the lack of appropriately labeled, specific nucleic acid probes. We describe two approaches for an expeditious preparation of chromosome-specific DNAs and the subsequent probe labeling with reporter molecules of choice. The described techniques allow the preparation of highly specific DNA repeat probes suitable for enumeration of chromosomes in interphase cell nuclei or tissue sections. In addition, there is no need for chromosome enrichment by flow cytometry and sorting or molecular cloning. Our PCR-based method uses either bacterial artificial chromosomes or human genomic DNA as templates with {alpha}-satellite-specific primers. Here we demonstrate the production of fluorochrome-labeled DNA repeat probes specific for human chromosomes 17 and 18 in just a few days without the need for highly specialized equipment and without the limitation to only a few fluorochrome labels.

  2. Relationship between income and repeat criminal victimization in Brazil

    Directory of Open Access Journals (Sweden)

    Marcelo Justus

    2015-09-01

    Full Text Available This study analyzes the effect of income on repeat criminal victimization in Brazil using data from the 2009 National Household Sample Survey and its special supplement on victimization and access to justice. Two count-data models were estimated for four types of crime: theft, robbery, attempted theft/robbery, and physical assault. A positive nonlinear effect of income on repeat victimization for the three types of property crimes and a negative nonlinear effect of income on physical assault were observed.

  3. Repeat polymorphisms in ESR2 and AR and colorectal cancer risk and prognosis: results from a German population-based case-control study.

    Science.gov (United States)

    Rudolph, Anja; Shi, Hong; Försti, Asta; Hoffmeister, Michael; Sainz, Juan; Jansen, Lina; Hemminki, Kari; Brenner, Hermann; Chang-Claude, Jenny

    2014-11-07

    Evidence has accumulated which suggests that sex steroids influence colorectal cancer development and progression. We therefore assessed the association of repeat polymorphisms in the estrogen receptor β gene (ESR2) and the androgen receptor gene (AR) with colorectal cancer risk and prognosis. The ESR2 CA and AR CAG repeat polymorphisms were genotyped in 1798 cases (746 female, 1052 male) and 1810 controls (732 female, 1078 male), matched for sex, age and county of residence. Colorectal cancer risk associations overall and specific for gender were evaluated using multivariate logistic regression models adjusted for sex, county of residence and age. Associations with overall and disease-specific survival were evaluated using Cox proportional hazard models adjusted for established prognostic factors (diagnosis of other cancer after colorectal cancer diagnosis, detection by screening, treatment with adjuvant chemotherapy, tumour extent, nodal status, distant metastasis, body mass index, age at diagnosis and year of diagnosis) and stratified for grade of differentiation. Heterogeneity in gender specific associations was assessed by comparing models with and without a multiplicative interaction term by means of a likelihood ratio test. The average number of ESR2 CA repeats was associated with a small 5% increase in colorectal cancer risk (OR = 1.05, 95% CI 1.01-1.10) without significant heterogeneity according to gender or tumoural ESR2 expression. We found no indication for an association between the AR CAG repeat polymorphisms and risk of colorectal cancer. The ESR2 CA and AR CAG repeat polymorphisms were not associated with overall survival or disease specific survival after colorectal cancer diagnosis. Higher numbers of ESR2 CA repeats are potentially associated with a small increase in colorectal cancer risk. Our study does not support an association between colorectal cancer prognosis and the investigated repeat polymorphisms.

  4. The Effects of Aquatic Plyometric Training on Repeated Jumps, Drop Jumps and Muscle Damage.

    Science.gov (United States)

    Jurado-Lavanant, A; Alvero-Cruz, J R; Pareja-Blanco, F; Melero-Romero, C; Rodríguez-Rosell, D; Fernandez-Garcia, J C

    2015-09-22

    The purpose of this study was to compare the effects of land- vs. aquatic based plyometric training programs on the drop jump, repeated jump performance and muscle damage. Sixty-five male students were randomly assigned to one of 3 groups: aquatic plyometric training group (APT), plyometric training group (PT) and control group (CG). Both experimental groups trained twice a week for 10 weeks performing the same number of sets and total jumps. The following variables were measured prior to, halfway through and after the training programs: creatine kinase (CK) concentration, maximal height during a drop jump from the height of 30 (DJ30) and 50 cm (DJ50), and mean height during a repeated vertical jump test (RJ). The training program resulted in a significant increase (Pplyometric training, PT produced greater gains on reactive jumps performance than APT. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Repetibilidade e número mínimo de medições para caracteres de cacho de bacabi (Oenocarpus mapora Repeatability and minimum number of measurements for characters of bacabi palm (Oenocarpus mapora racemes

    Directory of Open Access Journals (Sweden)

    Maria do Socorro Padilha de Oliveira

    2010-12-01

    potential for commercial and food uses, but has not been well studied. The objectives of this study were to estimate the repeatability coefficients, determine predictability and the number of measurements needed for raceme characters of this palm. 27 individuals of bacabi that belong to the Germplasm Bank of Oenocarpus/Jessenia at Embrapa Eastern Amazon, in Belém, PA, Brazil were evaluated. Three fully matured racemes from each plant were sampled to measure six characters: total weight of raceme (TWR and fruit weight per raceme (FWR, number of rachillae per raceme (NRR, rachis length per raceme (RLR, weight of 100 fruits (WHF and fruit yield per raceme (FER. The repeatability estimates were obtained by three statistical methods: analysis of variance; principal components; and structural analysis. For all characters, the estimates of repeatability coefficients presented values with very similar magnitudes in the three methods. The estimates of repeatability coefficients and determination coefficients were relatively high (r 0.60 and R2 81.7% for the characters FER and NRR, showing genotype regularity for these raceme measurements. For these characters, the minimum number of racemes necessary to estimate the true character value of the genotypes was thirteen (FER and five (NRR, with 95% reliability. The remaining characters showed repeatabilities and determination coefficients with medium to low values, indicating the need for better environmental control to make the measurements.

  6. Novel expressed sequence tag- simple sequence repeats (EST ...

    African Journals Online (AJOL)

    Using different bioinformatic criteria, the SUCEST database was used to mine for simple sequence repeat (SSR) markers. Among 42,189 clusters, 1,425 expressed sequence tag- simple sequence repeats (EST-SSRs) were identified in silico. Trinucleotide repeats were the most abundant SSRs detected. Of 212 primer pairs ...

  7. Absence of bacterial resistance following repeat exposure to photodynamic therapy

    Science.gov (United States)

    Pedigo, Lisa A.; Gibbs, Aaron J.; Scott, Robert J.; Street, Cale N.

    2009-06-01

    The prevalence of antibiotic resistant bacteria necessitates exploration of alternative approaches to treat hospital and community acquired infections. The aim of this study was to determine whether bacterial pathogens develop resistance to antimicrobial photodynamic therapy (aPDT) during repeated sub-lethal challenge. Antibiotic sensitive and resistant strains of S. aureus and antibiotic sensitive E. coli were subjected to repeat PDT treatments using a methylene blue photosensitizer formulation and 670 nm illumination from a non-thermal diode laser. Parameters were adjusted such that kills were antibiotic resistance strains. Furthermore, repeated sub-lethal exposure does not induce resistance to subsequent PDT treatments. The absence of resistance formation represents a significant advantage of PDT over traditional antibiotics.

  8. Expected satiation after repeated consumption of low- or high-energy-dense soup.

    Science.gov (United States)

    Hogenkamp, Pleunie S; Brunstrom, Jeffrey M; Stafleu, Annette; Mars, Monica; de Graaf, Cees

    2012-07-14

    We investigated whether repeated consumption of a low-energy-dense (LED; 208 kJ/100 g) or high-energy-dense (HED; 645 kJ/100 g) soup modifies expectations relating to the satiating capacity of the food, and its subsequent intake. In study 1, participants consumed either a novel-flavoured LED (n 32; 21 (SD 1·6) years, BMI 21·4 (SD 1·6) kg/m(2)) or HED soup (n 32; 21 (SD 1·6) years, BMI 21·3 (SD 1·7) kg/m(2)). Soup was served in a fixed amount on days 1-4 and ad libitum on day 5. 'Expected satiation' was measured on days 1, 2 and 5. Expected satiation did not change after repeated consumption of the LED or HED soup. Ad libitum intake did not differ between the LED (461 (SD 213) g) and HED soup (391 (SD 164) g). Only on day 1, expected satiation was higher for the HED soup than for the LED soup (P = 0·03), suggesting a role for sensory attributes in expected satiation. In study 2, thirty participants (21 (SD 1·6) years, BMI 21·3 (SD 1·7) kg/m(2)) performed a single measurement of expected satiation of the LED and HED soup, and four commercially available types of soup. Ratings on sensory attributes were associated with expected satiation. Results on expected satiation coincided with those of study 1. Thickness and intensity of taste were independently associated with expected satiation. Expectations may initially rely on sensory attributes and previous experiences, and are not easily changed.

  9. Role of memory errors in quantum repeaters

    International Nuclear Information System (INIS)

    Hartmann, L.; Kraus, B.; Briegel, H.-J.; Duer, W.

    2007-01-01

    We investigate the influence of memory errors in the quantum repeater scheme for long-range quantum communication. We show that the communication distance is limited in standard operation mode due to memory errors resulting from unavoidable waiting times for classical signals. We show how to overcome these limitations by (i) improving local memory and (ii) introducing two operational modes of the quantum repeater. In both operational modes, the repeater is run blindly, i.e., without waiting for classical signals to arrive. In the first scheme, entanglement purification protocols based on one-way classical communication are used allowing to communicate over arbitrary distances. However, the error thresholds for noise in local control operations are very stringent. The second scheme makes use of entanglement purification protocols with two-way classical communication and inherits the favorable error thresholds of the repeater run in standard mode. One can increase the possible communication distance by an order of magnitude with reasonable overhead in physical resources. We outline the architecture of a quantum repeater that can possibly ensure intercontinental quantum communication

  10. DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats.

    Science.gov (United States)

    de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas

    2015-11-16

    Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Association of aromatase (TTTA)n repeat polymorphisms with central precocious puberty in girls.

    Science.gov (United States)

    Lee, Hae Sang; Kim, Kyung Hee; Hwang, Jin Soon

    2014-09-01

    Precocious puberty is characterized by early activation of the pituitary-gonadal axis. Oestrogen is the final key factor to start the onset of puberty. The cytochrome P450 19A1 (CYP19A1) gene encodes an aromatase that is responsible for the conversion of androgens to oestrogen, which is a key step in oestrogen biosynthesis. The aim of this study was to identify CYP19A1 gene mutations or polymorphisms in girls with central precocious puberty (CPP). We evaluated the frequency of allelic variants of the CYP19A1 exons and the tetranucleotide tandem repeat (TTTA)n in intron 4 in 203 idiopathic central precocious puberty (CPP) girls and 101 normal healthy women. The genotype analysis of the CYP19A1 (TTTA)n polymorphism revealed six different alleles ranging from seven to 13 repeats. Among the six different repeat alleles detected in this study, the (TTTA)₁₃ repeat allele was only detected in the patient group and carriers of the (TTTA)₁₃ allele were significantly associated with an increased risk of CPP (OR = 1·509, 95% CI = 1·425-1·598, P = 0·033). Carriers of the (TTTA)₁₃ repeat allele were significantly younger at pubertal onset and had higher levels of oestrogen than noncarriers of the (TTTA)₁₃ repeat allele. Although nine polymorphisms were detected in exons of the CYP19A1 gene, no clinical significance was observed. In this study, carriers of a higher repeat (TTTA)₁₃ polymorphism in intron 4 of the CYP19A1 gene had higher levels of oestrogen. Those carrying the (TTTA)₁₃ repeat allele may have a higher risk of developing CPP. © 2014 John Wiley & Sons Ltd.

  12. Preventive maintenance measures and repeat tests on actuators

    International Nuclear Information System (INIS)

    Hueren, H.

    1990-01-01

    At Biblis Nuclear Power Station, about 1500 electrical actuators and variable speed drives of various model ranges and with various driving end speeds and actuating times are installed and about 600 of these are located in important safety engineering systems. In order to optimize the preventive maintenance measures on the drives, a data bank has been established into which are stored, in addition to the fixed type data of each drive, inter alia, statements about location of application, valve type, inspection cycle, calendar year of next maintenance, findings during inspection measures and causes of faults. Before each unit inspection, in addition to the inspection lists, the maintenance and installation records and also the associated job instructions are produced from this data processing equipment. (orig.) [de

  13. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Effects of repeated transport on Holstein calf post-transport behavior and feed intake.

    Science.gov (United States)

    Adams-Progar, A L; Friend, T H; Holub, G A; Krenek, A J; Garey, S M; Terrill, C L

    2015-02-01

    Previous studies have determined that stress causes decreases in feed intake and efficiency in livestock, but the effect of repeated transport on these parameters has not been well studied. This study determined how repeated transport affected calf post-transport behavior, feed intake, ADG, and feed conversion. Thirty-six 4-mo-old Holstein steer calves were housed in groups of 6 with each group randomly assigned to either transport or control treatments. Each calf was assigned to an individual Calan gate feeder and feed intake was recorded daily. Transport calves were transported for 6 h in their groups in a 7.3 by 2.4 m gooseneck trailer divided into 3 compartments, at an average density of 0.87 m/calf, every 7 d for 5 consecutive weeks. After return to their home pens, behavior was recorded for transported calves at 5-min intervals for 1 h. Calf ADG and feed conversion were analyzed in a mixed model ANOVA, whereas feed intake was analyzed as a repeated measure in a mixed model ANOVA. Post-transport, calves followed a pattern of drinking, eating, and then lying down. The highest (82 ± 5% calves) and lowest (0 ± 5% calves) incidences of eating behavior occurred 10 and 60 min post-transport, respectively. Control calves had a higher feed intake than transported calves overall (7.29 ± 0.22 kg for control and 6.91 ± 0.21 kg for transport; = 0.01), for the feeding posttreatment (6.78 ± 0.27 kg for control and 6.01 ± 0.28 kg for transport; = 0.007), and the day after treatment (7.83 ± 0.23 kg for control and 7.08 ± 0.15 kg for transport; = 0.02). Feed intake for the feeding post-transport for transport calves significantly decreased after the second transport but increased with each successive transport ( < 0.0001). Overall, control calves had higher ADG than transported calves (1.34 ± 0.13 kg/d for control and 1.15 ± 0.12 kg/d for transport; = 0.006). No significant difference ( = 0.12) between treatments was detected for feed conversion. These results

  15. The properties and interrelationships of various force-time parameters during maximal repeated rhythmic grip.

    Science.gov (United States)

    Nakada, Masakatsu; Demura, Shinichi; Yamaji, Shunsuke

    2007-01-01

    The purpose of this study was to examine the properties and interrelationships of various force-time parameters including the inflection point for the rate of decline in force during a maximal repeated rhythmic grip. Fifteen healthy males (age M=21.5, SD=2.1 yr, height M=172.4, SD=5.7 cm, body mass M=68.2, SD=9.2 kg) participated in this study. Subjects performed a maximal repeated rhythmic grip with maximal effort with a target frequency of 30 grip.min(-1) for 6 min. The force value decreased linearly and markedly until about 70% of maximal strength for about 55 s after the onset of a maximal repeated rhythmic grip, and then decreased moderately. Because all parameters showed fair or good correlations between 3 min and 6 min, they are considered to be able to sufficiently evaluate muscle endurance for 3 min instead of 6 min. However, there were significant differences between 3 min and 6 min in the integrated area, the final force, the rate of the decrement constant (k) fitting the force decreasing data to y=ae(-kx)+b and the force of maximal difference between the force and a straight line from peak force to the final force. Their parameters may vary generally by the length of a steady state, namely, a measurement time. The final force value before finishing and the rate of the decrement constant (k) reflect the latter phase during a maximal repeated rhythmic grip. Although many parameters show relatively high mutual relationships, the rate constant (k) shows relatively low correlations with other parameters. We inferred that decreasing the time until 80% of maximal strength and the amount of the decrement force for the first 1 min reflect a linear decrease in the initial phase.

  16. Erroneous Memories Arising from Repeated Attempts to Remember

    Science.gov (United States)

    Henkel, Linda A.

    2004-01-01

    The impact of repeated and prolonged attempts at remembering on false memory rates was assessed in three experiments. Participants saw and imagined pictures and then made repeated recall attempts before taking a source memory test. Although the number of items recalled increased with repeated tests, the net gains were associated with more source…

  17. Attrition from Web-Based Cognitive Testing: A Repeated Measures Comparison of Gamification Techniques.

    Science.gov (United States)

    Lumsden, Jim; Skinner, Andy; Coyle, David; Lawrence, Natalia; Munafo, Marcus

    2017-11-22

    The prospect of assessing cognition longitudinally and remotely is attractive to researchers, health practitioners, and pharmaceutical companies alike. However, such repeated testing regimes place a considerable burden on participants, and with cognitive tasks typically being regarded as effortful and unengaging, these studies may experience high levels of participant attrition. One potential solution is to gamify these tasks to make them more engaging: increasing participant willingness to take part and reducing attrition. However, such an approach must balance task validity with the introduction of entertaining gamelike elements. This study aims to investigate the effects of gamelike features on participant attrition using a between-subjects, longitudinal Web-based testing study. We used three variants of a common cognitive task, the Stop Signal Task (SST), with a single gamelike feature in each: one variant where points were rewarded for performing optimally; another where the task was given a graphical theme; and a third variant, which was a standard SST and served as a control condition. Participants completed four compulsory test sessions over 4 consecutive days before entering a 6-day voluntary testing period where they faced a daily decision to either drop out or continue taking part. Participants were paid for each session they completed. A total of 482 participants signed up to take part in the study, with 265 completing the requisite four consecutive test sessions. No evidence of an effect of gamification on attrition was observed. A log-rank test showed no evidence of a difference in dropout rates between task variants (χ 2 2 =3.0, P=.22), and a one-way analysis of variance of the mean number of sessions completed per participant in each variant also showed no evidence of a difference (F 2,262 =1.534, P=.21, partial η 2 =0.012). Our findings raise doubts about the ability of gamification to reduce attrition from longitudinal cognitive testing studies

  18. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study

    NARCIS (Netherlands)

    Aten, J.J.; Oudega, M.L.; van Exel, E.; Stek, M.L.; van Waarde, J.A.

    2015-01-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment

  19. Lesser Neural Pattern Similarity across Repeated Tests Is Associated with Better Long-Term Memory Retention.

    Science.gov (United States)

    Karlsson Wirebring, Linnea; Wiklund-Hörnqvist, Carola; Eriksson, Johan; Andersson, Micael; Jonsson, Bert; Nyberg, Lars

    2015-07-01

    Encoding and retrieval processes enhance long-term memory performance. The efficiency of encoding processes has recently been linked to representational consistency: the reactivation of a representation that gets more specific each time an item is further studied. Here we examined the complementary hypothesis of whether the efficiency of retrieval processes also is linked to representational consistency. Alternatively, recurrent retrieval might foster representational variability--the altering or adding of underlying memory representations. Human participants studied 60 Swahili-Swedish word pairs before being scanned with fMRI the same day and 1 week later. On Day 1, participants were tested three times on each word pair, and on Day 7 each pair was tested once. A BOLD signal change in right superior parietal cortex was associated with subsequent memory on Day 1 and with successful long-term retention on Day 7. A representational similarity analysis in this parietal region revealed that beneficial recurrent retrieval was associated with representational variability, such that the pattern similarity on Day 1 was lower for retrieved words subsequently remembered compared with those subsequently forgotten. This was mirrored by a monotonically decreased BOLD signal change in dorsolateral prefrontal cortex on Day 1 as a function of repeated successful retrieval for words subsequently remembered, but not for words subsequently forgotten. This reduction in prefrontal response could reflect reduced demands on cognitive control. Collectively, the results offer novel insights into why memory retention benefits from repeated retrieval, and they suggest fundamental differences between repeated study and repeated testing. Repeated testing is known to produce superior long-term retention of the to-be-learned material compared with repeated encoding and other learning techniques, much because it fosters repeated memory retrieval. This study demonstrates that repeated memory

  20. MNS16A tandem repeat minisatellite of human telomerase gene: functional studies in colorectal, lung and prostate cancer.

    Science.gov (United States)

    Hofer, Philipp; Zöchmeister, Cornelia; Behm, Christian; Brezina, Stefanie; Baierl, Andreas; Doriguzzi, Angelina; Vanas, Vanita; Holzmann, Klaus; Sutterlüty-Fall, Hedwig; Gsur, Andrea

    2017-04-25

    MNS16A, a functional polymorphic tandem repeat minisatellite, is located in the promoter region of an antisense transcript of the human telomerase reverse transcriptase gene. MNS16A promoter activity depends on the variable number of tandem repeats (VNTR) presenting varying numbers of transcription factor binding sites for GATA binding protein 1. Although MNS16A has been investigated in multiple cancer epidemiology studies with incongruent findings, functional data of only two VNTRs (VNTR-243 and VNTR-302) were available thus far, linking the shorter VNTR to higher promoter activity.For the first time, we investigated promoter activity of all six VNTRs of MNS16A in cell lines of colorectal, lung and prostate cancer using Luciferase reporter assay. In all investigated cell lines shorter VNTRs showed higher promoter activity. While this anticipated indirect linear relationship was affirmed for colorectal cancer SW480 (P = 0.006), a piecewise linear regression model provided significantly better model fit in lung cancer A-427 (P = 6.9 × 10-9) and prostate cancer LNCaP (P = 0.039). In silico search for transcription factor binding sites in MNS16A core repeat element suggested a higher degree of complexity involving X-box binding protein 1, general transcription factor II-I, and glucocorticoid receptor alpha in addition to GATA binding protein 1.Further functional studies in additional cancers are requested to extend our knowledge of MNS16A functionality uncovering potential cancer type-specific differences. Risk alleles may vary in different malignancies and their determination in vitro could be relevant for interpretation of genotype data.