WorldWideScience

Sample records for repeated measures factorial

  1. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  2. Evaluation of corrosion of steel embedded in concrete exposed to carbonation AAS using a factorial experiment with repeated measures. Evaluación de la corrosión del acero embebido en concreto AAS, expuesto a carbonatación mediante un experimento factorial con medidas repetidas.

    Directory of Open Access Journals (Sweden)

    W Aperador Chaparro

    2013-03-01

    Full Text Available This article presents various techniques for assessing corrosion, the linear polarization resistance and galvanostatic pulse, the analysis was performed using analysis of variance models using a factorial experiment with three factors, one repeated measure, because on the same experimental unit (reinforced concrete, it experienced several samples to be measured in time (0 h=1, 350 h=2, 700 h=3, 1050 h=4, 1700 h=5 y 2600 h=6. This makes the observations are not independent, the other two factors relate to, the binder (ce: 1 = activatedslag [AAS] and 2 = ordinary Portland concrete [OPC] and the exposure condition (ca: 1 = y 2 = environmental exposure accelerated carbonation. These factors were discussed according to the results of the electrochemical properties. Initially performed the statistical processing of each of the variables in relation to the properties and analyzed the interaction between them. Where they established the differences in materials used as coating steel, concrete, OPC and AAS. OPC concrete specimens, exhibited a resting potential, polarization resistance and ohmic (CO2 condition than those obtained for reinforced concrete in AAS.En este artículo se presentan las técnicas de evaluación de la corrosión, tales como potencial de corrosión, resistencia lineal a la polarización y pulso galvanostático a los concretos de activación alcalina (AAS y Portland tipo I (OPC. El estudio se realizó por medio de modelos de análisis de varianza, aplicando un experimento factorial con tres factores, uno de ellos medida repetida, debido a que sobre la misma unidad experimental (concreto armado AAS y OPC se ensayaron varias muestras para medirlas en el tiempo (0 h=1, 350 h=2, 700 h=3, 1050 h=4, 1700 h=5 y 2600 h=6, lo que hace que las observaciones no sean independientes; los otros dos factores corresponden al cementante (ce: 1=escoria activada alcalinamente [AAS] y 2=concreto Portland ordinario [OPC] y la condición de exposici

  3. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  4. Golden measurements at a neutrino factory

    International Nuclear Information System (INIS)

    Cervera, A.; Donini, A.; Gavela, M.B.; Gomez Cadenas, J.J.; Hernandez, P.; Mena, O.; Rigolin, S.

    2000-01-01

    The precision and discovery potential of a neutrino factory based on muon storage rings is studied. For three-family neutrino oscillations, we analyse how to measure or severely constraint the angle θ 13 , CP-violation, MSW effects and the sign of the atmospheric mass difference Δm 2 23 . We present a simple analytical formula for the oscillation probabilities in matter, with all neutrino mass differences non-vanishing, which clarifies the subtleties involved in disentangling the unknown parameters. The appearance of 'wrong-sign muons' at three reference baselines is considered: 732 km, 3500 km, and 7332 km. We exploit the dependence of the signal on the neutrino energy, and include as well realistic background estimations and detection efficiencies. The optimal baseline turns out to be O (3000 km). Analyses combining the information from different baselines are also presented

  5. Golden measurements at a neutrino factory

    CERN Document Server

    Cervera-Villanueva, Anselmo; Gavela-Legazpi, Maria Belen; Cadenas, J J G; Hernández, Pilar; Mena, O; Rigolin, Stefano

    2000-01-01

    The precision and discovery potential of a neutrino factory based on muonstorage rings is studied. For three-family neutrino oscillations, we analysehow to measure or severely constraint the angle $\\theta_{13}$, CP violation,MSW effects and the sign of the atmospheric mass difference $\\Delta m^2_{23}$.We present a simple analytical formula for the oscillation probabilities inmatter, with all neutrino mass differences non-vanishing, which clarifies thesubtleties involved in disentangling the unknown parameters. The appearance of``wrong-sign muons'' at three reference baselines is considered: 732 km, 3500km, and 7332 km. We exploit the dependence of the signal on the neutrinoenergy, and include as well realistic background estimations and detectionefficiencies. The optimal baseline turns out to be ${\\cal O}(3000$ km).Analyses combining the information from different baselines are also presented.

  6. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.; Maity, A.; Mammen, E.; Yu, K.

    2009-01-01

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements

  7. Measurement of CP violation at a Neutrino Factory

    CERN Document Server

    Gómez-Cadenas, J J

    2001-01-01

    The prospects of measuring CP violation in the leptonic sector using the intense neutrino beams arising from muon decay in the straight sections of a muon accumulator ring (the so-called neutrino factory) are discussed.

  8. Measurement of Air Pollution Comes from Adra Cement Factory

    International Nuclear Information System (INIS)

    Odat, M.; Meslmani, Y.; Al-Kharfan, K.; Shamali, K.

    2013-06-01

    Measurements of air pollution were carried out in and around Adra cement factory during a single period (December). The Measurements included the following: 1- Dust fall. 2- Total suspended particulates (TSP) and inhalable particulates PM-1-0 & PM-3 inside the factor and in residential area surrounded the factory (Worker City of Adra, Adra city, Wafeden Mokheam, Baironi Hospital and Alkatiefa City). 3-Determination the levels of Cd, Pb, Cu and zinc associated with air born. 4- Determination of toxic gases (CO, SO-2 and NO-x) emitted from the chimneys. The results showed that the quantity of dust fall was varied obviously inside the factory and the regions affected by air pollutions. The monthly concentration of dust fall were 165, 27 and 10 tons/Km 2 /month inside the factory , affected villages and Baironi Hospital respectively, Wherein the permissible limit is (9tons/Km'2/month). The total suspended particulates (TSP) and inhalable particulates PM-1-0 & PM-3 in the studies area were higher than the permissible limit. The TSP concentrations inside the factory ranged between 497 and 2021 microgram/m'3 while the ranged between 328 and 561 microgram /m'3 in the surrounded villages and between 232 and 244 microgram/m'3 near Damascus, the were far higher than the world health organization (WHO) standards (120 Microgram/m'3). The PM-3 which is the most effecting on the human health reached 117.6, 124.6 and 62.6 microgram /m 3 inside the factory (main in trance), city worker of Adra and Baironi Hospital respectively, theses concentrations were higher than the Syrian standards (15 microgram/m'3) The measurements which were carried out through an exclusive day refered that the percentage of TSP/PM-3 is increasedwith moving away from the factory and reached 6.8, 18.6, 19.3% in the main intrance of the factory, worker city of Adra and Bironi Hospital respectively. The level of toxic gases inside the source (chimneys) was within the standards

  9. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  10. The vibration measurements at the photon factory storage ring building

    International Nuclear Information System (INIS)

    Haga, K.; Nakayama, M.; Masuda, K.; Ishizaki, H.; Kura, M.; Meng, L.; Oku, Y.

    1999-01-01

    The Photon Factory is a 2.5 GeV electron storage ring and has been operating since 1982 as a dedicated SR source. At the Photon Factory, we have been pursuing the various sources of the beam instabilities which deteriorated the SR beam quality in the wide frequency range. Some of the sources were the vibrations of magnets and floor of the ring tunnel, temperature change of the cooling water and the elongation of the storage ring building roof due to sunshine that induced the diurnal motion of the SR beam axis. This article presents the results of the vibration measurements that have been performed at the Photon Factory storage ring building. (1) The vibrations of the ring tunnel floor and the experimental hall floor, comparing with the vibration of the ground surrounding the storage ring building, are same order in the 1 ∼ 5 Hz range, and 1/3 ∼ 1/5 in the 5 ∼ 100 Hz range, in the vertical and the horizontal direction. (2) The effects of the vibration arising from the operating eight air-conditioners can be seen in the Fourier spectrum of the vibration of the ring tunnel floor, experimental floor, Q-magnets and BPM vacuum duct. (3) The vibrations of the Q-magnet and girder at frequencies near their fundamental resonant frequencies have been amplified 100 limes in the lateral direction comparing to the floor vibration. (4) Correlation between the vibration of the BPM vacuum duct and the vibration of the electron beam motion is unknown for the lack of the precise data. (authors)

  11. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  12. Measurement of Employability Skills on Teaching Factory Learning

    Science.gov (United States)

    Subekti, S.; Ana, A.

    2018-02-01

    Vocational High Schools as one of the educational institutions that has the responsibility in preparing skilled labors has a challenge to improve the quality of human resources as a candidate for skilled labors, to compete and survive in a changing climate of work. BPS noted an increase in the number of non-worker population (BAK) in 2015-2017 on vocational graduates as many as 564,272 people. The ability to adapt and maintain jobs in a variety of conditions is called employability skills. This study purpose to measure the development of employability skills of communication skills, problem-solving skills and teamwork skills on the implementation of teaching factory learning in SMK Negeri 1 Cibadak, THPH Skills Program on bakery competency. This research uses mixed method, with concurrent triangulation mix methods research design. Data collection techniques used interviews and questionnaires. The result shows that there are increasing students’ employability skills in communication skills, problem solving skills, and teamwork skills in teaching factory learning. Principles of learning that apply learning by doing student centering and learning arrangements such as situations and conditions in the workplace have an impact on improving student employability skills.

  13. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...... to sphericity assumptions, use of F tests and the Greenhouse-Geisser and Huynh-Feldt adjustments to compensate for deviations from sphericity. During a recent implementation of such methods in the R language, the general structure of such transformations was reconsidered, leading to a flexible specification...

  14. Methods for analysing cardiovascular studies with repeated measures

    NARCIS (Netherlands)

    Cleophas, T. J.; Zwinderman, A. H.; van Ouwerkerk, B. M.

    2009-01-01

    Background. Repeated measurements in a single subject are generally more similar than unrepeated measurements in different subjects. Unrepeated analyses of repeated data cause underestimation of the treatment effects. Objective. To review methods adequate for the analysis of cardiovascular studies

  15. A multiple-locus variable-number tandem repeat analysis (MLVA) of Listeria monocytogenes isolated from Norwegian salmon-processing factories and from listeriosis patients.

    Science.gov (United States)

    Lunestad, B T; Truong, T T T; Lindstedt, B-A

    2013-10-01

    The objective of this study was to characterize Listeria monocytogenes isolated from farmed Atlantic salmon (Salmo salar) and the processing environment in three different Norwegian factories, and compare these to clinical isolates by multiple-locus variable-number tandem repeat analysis (MLVA). The 65 L. monocytogenes isolates obtained gave 15 distinct MLVA profiles. There was great heterogeneity in the distribution of MLVA profiles in factories and within each factory. Nine of the 15 MLVA profiles found in the fish-associated isolates were found to match human profiles. The MLVA profile 07-07-09-10-06 was the most common strain in Norwegian listeriosis patients. L. monocytogenes with this profile has previously been associated with at least two known listeriosis outbreaks in Norway, neither determined to be due to fish consumption. However, since this profile was also found in fish and in the processing environment, fish should be considered as a possible food vehicle during sporadic cases and outbreaks of listeriosis.

  16. A method to identify energy efficiency measures for factory systems based on qualitative modeling

    CERN Document Server

    Krones, Manuela

    2017-01-01

    Manuela Krones develops a method that supports factory planners in generating energy-efficient planning solutions. The method provides qualitative description concepts for factory planning tasks and energy efficiency knowledge as well as an algorithm-based linkage between these measures and the respective planning tasks. Its application is guided by a procedure model which allows a general applicability in the manufacturing sector. The results contain energy efficiency measures that are suitable for a specific planning task and reveal the roles of various actors for the measures’ implementation. Contents Driving Concerns for and Barriers against Energy Efficiency Approaches to Increase Energy Efficiency in Factories Socio-Technical Description of Factory Planning Tasks Description of Energy Efficiency Measures Case Studies on Welding Processes and Logistics Systems Target Groups Lecturers and Students of Industrial Engineering, Production Engineering, Environmental Engineering, Mechanical Engineering Practi...

  17. Leptonic CP Violation measurement at the neutrino factory

    International Nuclear Information System (INIS)

    Burguet Castell, J.; Mena, O.

    2003-01-01

    In this talk, based on the work [J. Burguet Castell, et al., Nucl. Phys. B 608 (2001) 301], we refine our previous analysis [A. Cervera, et al., Nucl. Phys. B 579 (2000) 17] of the sensitivity to leptonic CP violation and θ 13 at a neutrino factory in the LMA-MSW scenario, by exploring the full range of these two parameters. We have discovered that there exist, at fixed neutrino energy, E ν , and baseline, L, degenerate solutions. Although the spectral analysis helps in disentangling fake from true solutions, a leftover product of this degeneracy remains for a realistic detector, which we analyse. Furthermore, we take into account the expected uncertainties on the solar and atmospheric oscillation parameters and in the average Earth matter density along the neutrino path. An intermediate baseline of O(3000) km is still the best option to tackle CP violation, although a combination of two baselines turns out to be very important in resolving degeneracies

  18. Assessment of the confiability and factorial structure of three scales measuring chronic procrastination

    OpenAIRE

    Doris Argumedo Bustinza; Karem Díaz Cema; Arturo Calderón García; Juan Francisco Díaz-Morales; Joseph R. Ferrari

    2005-01-01

    This study explores the confiability and factorial structure of three scales measuring chronic procrastination: Scale of General Procrastination (EPG. Lay. 1986). Adult Procrastinatio Inventory (lPA. McCown & Johnson as cited in Ferrari. Johnson & McCown. 1995) and the Scale of Procrastination in Decision-Making (PTF. Mann. 1982). The sample included 514 adults between 20 and 65 years of age from Lima. The three scales showed high levels of intemal consistency and factorial analysis s...

  19. Investigation of the Effect of Control Measures on Reduction of Risk Events in an Edible Oil Factory in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Malihe Kolahdouzi

    2017-07-01

    Full Text Available Background & Aims of the Study: Identification of hazards is one of the first goals of risk analysis. Failure mode and effect analysis method (FMEA is universally defined as efficient procedures for finding potential failures aimed to remove or decrease the risk which is related to them. This study aimed to investigate the effect of control measures on reduction of risk events in an edible oil factory in Tehran. Methods: This cross-sectional study was conducted in an edible oil factory in Tehran, Iran. For this, a four-member team of safety engineer experts was formed. Some factory units were selected randomly. After that, in all units, probability, severity and detection probability of hazards in all processes and tasks were assessed based on FMEA method. Regarding to the RPN, some control measures were taken to reduce the risk of events. After 9 months, risk assessment was repeated; primary and secondary RPNs were compared with each other to investigate the effect of interventions. Results: The results showed that highest and lowest probability of hazard were related to installation and can production unit, respectively. The highest and lowest severity of hazard were related to tool and can production unit, respectively. There was a significant difference between the probability of hazard in can-making and filling units, before and after the interventions. There was a significant difference between the severity of hazard in can-making, filling and neutralization units, before and after the interventions. As well, total probability, severity and RPN had a significant difference in all parts of the factory before and after the interventions. Conclusions: According to the results of this study and the overall risk reduction caused by interventional measures, it can be concluded that, FMEA is a successful method for identifying hazards and risk control measures.

  20. Unstable systems and repeated measurements. II

    International Nuclear Information System (INIS)

    Exner, P.

    1977-01-01

    Two examples are treated. In the first, the chamber structure is only assumed to be periodic and P(t) is an exponential. In the second example no specific assumption is made about the primary decay law and the measuring device is structured as an idealized spark chamber. This example contains the results by Beskow and Nilsson as a special case. (author)

  1. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  2. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  3. The Factorial Structure of Four Temperament Styles and Measurement Invariance across Gender and Age Groups

    Science.gov (United States)

    Rowinski, Tomasz; Cieciuch, Jan; Oakland, Thomas

    2014-01-01

    The Polish Temperament Styles Questionnaire (PTSQ), derived from Student Style Questionnaire (SSQ) was developed to measure four bipolar temperament styles: extroverted versus introverted, practical versus imaginative, thinking versus feeling, and organized versus flexible. The study focuses on factorial validity and measurement invariance…

  4. Assessment of the confiability and factorial structure of three scales measuring chronic procrastination

    Directory of Open Access Journals (Sweden)

    Doris Argumedo Bustinza

    2005-06-01

    Full Text Available This study explores the confiability and factorial structure of three scales measuring chronic procrastination: Scale of General Procrastination (EPG. Lay. 1986. Adult Procrastinatio Inventory (lPA. McCown & Johnson as cited in Ferrari. Johnson & McCown. 1995 and the Scale of Procrastination in Decision-Making (PTF. Mann. 1982. The sample included 514 adults between 20 and 65 years of age from Lima. The three scales showed high levels of intemal consistency and factorial analysis showed three factors for EPG and IPA and one factor for PTD A second degree factorial analysis suggested the presence of only one factor based on the grouping of items of the EPG and IPA scales The study did not find theoretically relevant dlfferences in chronic procrastination according to gender, age or education level. However,with respect to socioeconomic status. there were higher levels of chronic procrastmation in the poorest sector

  5. Intra-examiner repeatability and agreement in accommodative response measurements.

    Science.gov (United States)

    Antona, B; Sanchez, I; Barrio, A; Barra, F; Gonzalez, E

    2009-11-01

    Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods. The AR of the right eye at one accommodative demand of 2.50 D (40 cm) was measured on two separate occasions in 61 visually normal subjects of mean age 19.7 years (range 18-32 years). The intraexaminer repeatability of the tests, and agreement between them, were estimated by the Bland-Altman method. We determined mean differences (MD) and the 95% limits of agreement [coefficient of repeatability (COR) and coefficient of agreement (COA)]. Nott retinoscopy and BCC offered the best repeatability, showing the lowest MD and narrowest 95% interval of agreement (Nott: -0.10 +/- 0.66 D, BCC: -0.05 +/- 0.75 D). The 95% limits of agreement for the four techniques were similar (COA = +/- 0.92 to +/-1.00 D) yet clinically significant, according to the expected values of the AR. The two dynamic retinoscopy techniques (Nott and MEM) had a better agreement (COA = +/-0.64 D) although this COA must be interpreted in the context of the low MEM repeatability (COR = +/-0.98 D). The best method of assessing AR was Nott retinoscopy. The BCC technique was also repeatable, and both are recommended as suitable methods for clinical use. Despite better agreement between MEM and Nott, agreement among the remaining methods was poor such that their interchangeable use in clinical practice is not recommended.

  6. Repeatability of Objective Measurements of Linear Udder and Body ...

    African Journals Online (AJOL)

    The objective of this study was to estimates the repeatability of objective measurements on linear udder and body conformation traits and to evaluate the objectivity of the measurements in Friesian x Bunaji cows. Data from 50 (F1) Frisian X Bunaji cows collected between 2007 and 2008 at the Dairy Research Farm of the ...

  7. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  8. Magnetic field measurements on the perpendicular biased RF booster cavity for the proposed TRIUMF KAON Factory

    International Nuclear Information System (INIS)

    Enchevich, I.B.; Poirier, R.L.

    1992-08-01

    The successful operation of the full scale KAON Factory Ferrite tuned Booster Accelerating Cavity Prototype allowed us to do ac magnetic field measurements in the tuner. The field measured is close to that calculated. The measured data are discussed. They may be used for reliable computation of the perturbation of the beam dynamics due to the ferrite biasing magnetic field. Methods to compensate the disturbing magnetic fields are discussed. 7 refs., 7 figs

  9. Occupational hazards and safety measures amongst the paint factory workers in lagos, Nigeria.

    Science.gov (United States)

    Awodele, Olufunsho; Popoola, Temidayo D; Ogbudu, Bawo S; Akinyede, Akin; Coker, Herbert A B; Akintonwa, Alade

    2014-06-01

    The manufacture of paint involves a variety of processes that present with medical hazards. Safety initiatives are hence introduced to limit hazard exposures and promote workplace safety. This aim of this study is to assess the use of available control measures/initiatives in selected paint factories in Lagos West Senatorial District, Nigeria. A total of 400 randomly selected paint factory workers were involved in the study. A well-structured World Health Organization standard questionnaire was designed and distributed to the workers to elicit information on awareness to occupational hazards, use of personal protective devices, and commonly experienced adverse symptoms. Urine samples were obtained from 50 workers randomly selected from these 400 participants, and the concentrations of the heavy metals (lead, cadmium, arsenic, and chromium) were determined using atomic absorption spectroscopy. The results show that 72.5% of the respondents are aware of the hazards associated with their jobs; 30% have had formal training on hazards and safety measures; 40% do not use personal protective devices, and 90% of the respondents reported symptoms relating to hazard exposure. There was a statistically significant (p metal concentrations in the urine samples obtained from paint factory workers as compared with nonfactory workers. The need to develop effective frameworks that will initiate the integration and ensure implementation of safety regulations in paint factories is evident. Where these exist, there is a need to promote adherence to these practice guidelines.

  10. Magnetic field measurements and data acquisition of a model magnet for the B-factory

    International Nuclear Information System (INIS)

    Zhou Wenming; Endo, Kuninori

    1994-01-01

    In this paper we describe magnetic field measurements and the field data-acquisition system used to measure the model magnet for the B-factory booster. The results of the measurements indicate that the method adopted here is good for acquiring field data. This type of measurement is highly accurate and involves almost no temperature coefficient. The instrument is used not only for ac, but also dc field measurements. It is especially good for field measurements in the case of simultaneous ac and dc field excitation. (author)

  11. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  12. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  13. An Automated and Continuous Plant Weight Measurement System for Plant Factory.

    Science.gov (United States)

    Chen, Wei-Tai; Yeh, Yu-Hui F; Liu, Ting-Yu; Lin, Ta-Te

    2016-01-01

    In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analog electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.

  14. An Automated and Continuous Plant Weight Measurement System for Plant Factory

    Directory of Open Access Journals (Sweden)

    Wei-Tai eChen

    2016-03-01

    Full Text Available In plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator. Traditional plant weight measurements are destructive and laborious. In order to measure and record the plant weight during plant growth, an automated measurement system was designed and developed herein. The weight measurement system comprises a weight measurement device and an imaging system. The weight measurement device consists of a top disk, a bottom disk, a plant holder and a load cell. The load cell with a resolution of 0.1 g converts the plant weight on the plant holder disk to an analogue electrical signal for a precise measurement. The top disk and bottom disk are designed to be durable for different plant sizes, so plant weight can be measured continuously throughout the whole growth period, without hindering plant growth. The results show that plant weights measured by the weight measurement device are highly correlated with the weights estimated by the stereo-vision imaging system; hence, plant weight can be measured by either method. The weight growth of selected vegetables growing in the National Taiwan University plant factory were monitored and measured using our automated plant growth weight measurement system. The experimental results demonstrate the functionality, stability and durability of this system. The information gathered by this weight system can be valuable and beneficial for hydroponic plants monitoring research and agricultural research applications.

  15. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  16. The effect of repeated applanation on subsequent IOP measurements.

    Science.gov (United States)

    AlMubrad, Turki M; Ogbuehi, Kelechi C

    2008-11-01

    In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (pcontact tonometer in both sessions. These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.

  17. A Study of Transmission Control Method for Distributed Parameters Measurement in Large Factories and Storehouses

    Directory of Open Access Journals (Sweden)

    Shujing Su

    2015-01-01

    Full Text Available For the characteristics of parameters dispersion in large factories, storehouses, and other applications, a distributed parameter measurement system is designed that is based on the ring network. The structure of the system and the circuit design of the master-slave node are described briefly. The basic protocol architecture about transmission communication is introduced, and then this paper comes up with two kinds of distributed transmission control methods. Finally, the reliability, extendibility, and control characteristic of these two methods are tested through a series of experiments. Moreover, the measurement results are compared and discussed.

  18. Neutrino Factory

    CERN Document Server

    Bogomilov, M; Tsenov, R; Dracos, M; Bonesini, M; Palladino, V; Tortora, L; Mori, Y; Planche, T; Lagrange, J  B; Kuno, Y; Benedetto, E; Efthymiopoulos, I; Garoby, R; Gilardoini, S; Martini, M; Wildner, E; Prior, G; Blondel, A; Karadzhow, Y; Ellis, M; Kyberd, P; Bayes, R; Laing, A; Soler, F  J  P; Alekou, A; Apollonio, M; Aslaninejad, M; Bontoiu, C; Jenner, L  J; Kurup, A; Long, K; Pasternak, J; Zarrebini, A; Poslimski, J; Blackmore, V; Cobb, J; Tunnell, C; Andreopoulos, C; Bennett, J  R  J; Brooks, S; Caretta, O; Davenne, T; Densham, C; Edgecock, T  R; Fitton, M; Kelliher, D; Loveridge, P; McFarland, A; Machida, S; Prior, C; Rees, G; Rogers, C; Rooney, M; Thomason, J; Wilcox, D; Booth, C; Skoro, G; Back, J  J; Harrison, P; Berg, J  S; Fernow, R; Gallardo, J  C; Gupta, R; Kirk, H; Simos, N; Stratakis, D; Souchlas, N; Witte, H; Bross, A; Geer, S; Johnstone, C; Mokhov, N; Neuffer, D; Popovic, M; Strait, J; Striganov, S; Morfín, J  G; Wands, R; Snopok, P; Bogacz, S  A; Morozov, V; Roblin, Y; Cline, D; Ding, X; Bromberg, C; Hart, T; Abrams, R  J; Ankenbrandt, C  M; Beard, K  B; Cummings, M  A  C; Flanagan, G; Johnson, R  P; Roberts, T  J; Yoshikawa, C  Y; Graves, V  B; McDonald, K  T; Coney, L; Hanson, G

    2014-01-01

    The properties of the neutrino provide a unique window on physics beyond that described by the standard model. The study of subleading effects in neutrino oscillations, and the race to discover CP-invariance violation in the lepton sector, has begun with the recent discovery that $\\theta_{13} > 0$. The measured value of $\\theta_{13}$ is large, emphasizing the need for a facility at which the systematic uncertainties can be reduced to the percent level. The neutrino factory, in which intense neutrino beams are produced from the decay of muons, has been shown to outperform all realistic alternatives and to be capable of making measurements of the requisite precision. Its unique discovery potential arises from the fact that only at the neutrino factory is it practical to produce high-energy electron (anti)neutrino beams of the required intensity. This paper presents the conceptual design of the neutrino factory accelerator facility developed by the European Commission Framework Programme 7 EURO$\

  19. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  20. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  1. Analysis of repeated measurement data in the clinical trials

    Science.gov (United States)

    Singh, Vineeta; Rana, Rakesh Kumar; Singhal, Richa

    2013-01-01

    Statistics is an integral part of Clinical Trials. Elements of statistics span Clinical Trial design, data monitoring, analyses and reporting. A solid understanding of statistical concepts by clinicians improves the comprehension and the resulting quality of Clinical Trials. In biomedical research it has been seen that researcher frequently use t-test and ANOVA to compare means between the groups of interest irrespective of the nature of the data. In Clinical Trials we record the data on the patients more than two times. In such a situation using the standard ANOVA procedures is not appropriate as it does not consider dependencies between observations within subjects in the analysis. To deal with such types of study data Repeated Measure ANOVA should be used. In this article the application of One-way Repeated Measure ANOVA has been demonstrated by using the software SPSS (Statistical Package for Social Sciences) Version 15.0 on the data collected at four time points 0 day, 15th day, 30th day, and 45th day of multicentre clinical trial conducted on Pandu Roga (~Iron Deficiency Anemia) with an Ayurvedic formulation Dhatrilauha. PMID:23930038

  2. Unitarity, Feedback, Interactions - Dynamics Emergent from Repeated Measurements

    Science.gov (United States)

    Corona Ugalde, Paulina; Altamirano, Natacha; Mann, Robert; Zych, Magdalena

    Modern measurement theory dispenses with the description of a measurement as a projection. Rather, the measurement is understood as an operation, whereby the system's final state is determined by an action of a completely positive trace non-increasing map and the outcomes are described by linear operators on the system, distributed according to a positive-operator valued measure (POVM). The POVM approach unifies the theory of measurements with a general description of dynamics, the theory of open quantum systems. Engineering a particular measurement and engineering a particular dynamics for the system are thus two complementary aspects of the same conceptual framework. This correspondence is directly applied in quantum simulations and quantum control theory . With this motivation, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence. For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions. The simple framework used in the present study can find applications in devising novel quantum control protocols, or quantum simulations.

  3. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  4. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  5. An examination of the factorial and convergent validity of four measures of conspiracist ideation, with recommendations for researchers.

    Directory of Open Access Journals (Sweden)

    Viren Swami

    Full Text Available A number scales have been developed to measure conspiracist ideation, but little attention has been paid to the factorial validity of these scales. We reassessed the psychometric properties of four widely-used scales, namely the Belief in Conspiracy Theories Inventory (BCTI, the Conspiracy Mentality Questionnaire (CMQ, the Generic Conspiracist Beliefs Scale (GCBS, and the One-Item Conspiracy Measure (OICM. Eight-hundred-and-three U.S. adults completed all measures, along with measures of endorsement of 9/11 and anti-vaccination conspiracy theories. Through both exploratory and confirmatory factor analysis, we found that only the BCTI had acceptable factorial validity. We failed to confirm the factor structures of the CMQ and the GBCS, suggesting these measures had poor factorial validity. Indices of convergent validity were acceptable for the BCTI, but weaker for the other measures. Based on these findings, we provide suggestions for the future refinement in the measurement of conspiracist ideation.

  6. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. On model selections for repeated measurement data in clinical studies.

    Science.gov (United States)

    Zou, Baiming; Jin, Bo; Koch, Gary G; Zhou, Haibo; Borst, Stephen E; Menon, Sandeep; Shuster, Jonathan J

    2015-05-10

    Repeated measurement designs have been widely used in various randomized controlled trials for evaluating long-term intervention efficacies. For some clinical trials, the primary research question is how to compare two treatments at a fixed time, using a t-test. Although simple, robust, and convenient, this type of analysis fails to utilize a large amount of collected information. Alternatively, the mixed-effects model is commonly used for repeated measurement data. It models all available data jointly and allows explicit assessment of the overall treatment effects across the entire time spectrum. In this paper, we propose an analytic strategy for longitudinal clinical trial data where the mixed-effects model is coupled with a model selection scheme. The proposed test statistics not only make full use of all available data but also utilize the information from the optimal model deemed for the data. The performance of the proposed method under various setups, including different data missing mechanisms, is evaluated via extensive Monte Carlo simulations. Our numerical results demonstrate that the proposed analytic procedure is more powerful than the t-test when the primary interest is to test for the treatment effect at the last time point. Simulations also reveal that the proposed method outperforms the usual mixed-effects model for testing the overall treatment effects across time. In addition, the proposed framework is more robust and flexible in dealing with missing data compared with several competing methods. The utility of the proposed method is demonstrated by analyzing a clinical trial on the cognitive effect of testosterone in geriatric men with low baseline testosterone levels. Copyright © 2015 John Wiley & Sons, Ltd.

  8. A Comparison of Three Job Engagement Measures: Examining their Factorial and Criterion-Related Validity.

    Science.gov (United States)

    Wefald, Andrew J; Mills, Maura J; Smith, Michael R; Downey, Ronald G

    2012-03-01

    Engagement is an emerging job attitude that purports to measure employees' psychological presence at and involvement in their work. This research compares three academic approaches to engagement, and makes recommendations regarding the most appropriate conceptualisation and measurement of the construct in future research. The current research also investigates whether any of these three approaches to engagement contribute unique variance to the prediction of turnover intentions above and beyond the predictive capacity of alternative constructs. An online survey was taken by 382 employees and managers from a mid-sized financial institution. Results failed to support either a multi- or unidimensional factor structure for the Utrecht Work Engagement Scale (UWES) engagement measure. For the Shirom-Melamed Vigor Measure (SMVM), a multi-dimensional structure was identified as a good fit, while a unidimensional structure fit poorly. The uni-factorial structure of Britt's engagement measure was confirmed. The Schaufeli measure of engagement was a strong predictor of work outcomes; however, when controlling for job satisfaction and affective commitment, that measure lost its ability to predict intentions to leave. Two components of the Shirom vigor measure held their predictive validity. Collectively, these findings suggest that the Shirom vigor measure may provide better insight into whether and how much a person is 'into' his or her job. The Schaufeli measure was a good predictor of important work outcomes, but when job satisfaction and affective commitment were controlled, it lost its predictive validity. We were not able to confirm the three-factor structure of the Schaufeli measure. Two components of the Shirom vigor measure predicted turnover intentions after controlling for job satisfaction and affective commitment, suggesting less overlap with those constructs than the Schaufeli measure of engagement. This research adds important information on the nature of

  9. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  10. Testing Mean Differences among Groups: Multivariate and Repeated Measures Analysis with Minimal Assumptions.

    Science.gov (United States)

    Bathke, Arne C; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne

    2018-03-22

    To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer's disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved.

  11. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    International Nuclear Information System (INIS)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-01-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of [ 3 H]Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in [14C]iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress [an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures], although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results

  12. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  13. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool – A literature review

    OpenAIRE

    Konrad Kulikowski

    2017-01-01

    Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES) is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA) approach have been reviewed in order to answer the question as to which of th...

  14. Occupational Hazards and Safety Measures Amongst the Paint Factory Workers in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Olufunsho Awodele

    2014-06-01

    Conclusion: The need to develop effective frameworks that will initiate the integration and ensure implementation of safety regulations in paint factories is evident. Where these exist, there is a need to promote adherence to these practice guidelines.

  15. Validation of the Dyadic Coping Inventory with Chinese couples: Factorial structure, measurement invariance, and construct validity.

    Science.gov (United States)

    Xu, Feng; Hilpert, Peter; Randall, Ashley K; Li, Qiuping; Bodenmann, Guy

    2016-08-01

    The Dyadic Coping Inventory (DCI, Bodenmann, 2008) assesses how couples support each other when facing individual (e.g., workload) and common (e.g., parenting) stressors. Specifically, the DCI measures partners' perceptions of their own (Self) and their partners' behaviors (Partner) when facing individual stressors, and partners' common coping behaviors when facing common stressors (Common). To date, the DCI has been validated in 6 different languages from individualistic Western cultures; however, because culture can affect interpersonal interactions, it is unknown whether the DCI is a reliable measure of coping behaviors for couples living in collectivistic Eastern cultures. Based on data from 474 Chinese couples (N = 948 individuals), the current study examined the Chinese version of the DCI's factorial structure, measurement invariance (MI), and construct validity of test scores. Using 3 cultural groups (China, Switzerland, and the United States [U.S.]), confirmatory factor analysis revealed a 5-factor structure regarding Self and Partner and a 2-factor structure regarding Common dyadic coping (DC). Results from analyses of MI indicated that the DCI subscales met the criteria for configural, metric, and full/partial scalar invariance across cultures (Chinese-Swiss and Chinese-U.S.) and genders (Chinese men and women). Results further revealed good construct validity of the DCI test scores. In all, the Chinese version of the DCI can be used for measuring Chinese couples' coping behaviors, and is available for cross-cultural studies examining DC behaviors between Western and Eastern cultures. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. Design of a Low Cost Smart Dryer Temperature Measurement System for Tea Factories

    Directory of Open Access Journals (Sweden)

    Utpal SARMA

    2009-09-01

    Full Text Available This paper presents the design of a low cost smart dryer temperature measurement system for Tea Factories using K-type Thermocouple implementing linearization polynomial. The thermo emf is amplified by an instrumentation amplifier having high CMRR (106 dB and high input impedance (1012 Ohm. The analog signal is converted to digital form with the help of an SPI compatible 12-bit ADC. Data acquisition and transmission is done with an 8- bit microcontroller. As the dependence of thermo emf on temperature is not linear hence it is fitted with a polynomial. NIST data for K-type TC is taken as a standard for this fitting. The error with linear fit and polynomial fit is also presented. The digital data is corrected according to the polynomial and sent to a PC located at a remote control room for monitoring and data logging via RS232C communication. The performance of the entire system is discussed in the paper.

  17. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  18. Particle factories

    International Nuclear Information System (INIS)

    Schindler, Rafe

    1989-01-01

    Physicists' attention is increasingly turning to the high luminosity frontier - providing enough collisions to amass sizable numbers of rare events - to complement the traditional quest for higher energies. This month we cover three areas where projects are now being considered: Phi-factory workshop, PSI Planning for B meson factory, Tau-charm factory

  19. Particle factories

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, Rafe

    1989-07-15

    Physicists' attention is increasingly turning to the high luminosity frontier - providing enough collisions to amass sizable numbers of rare events - to complement the traditional quest for higher energies. This month we cover three areas where projects are now being considered: Phi-factory workshop, PSI Planning for B meson factory, Tau-charm factory.

  20. Acute caffeine effect on repeatedly measured P300

    OpenAIRE

    Pan, Jingbo; Takeshita, Tatsuya; Morimoto, Kanehisa

    2000-01-01

    The acute effect of a single-dose of caffeine on the P300 event-related brain potential (ERP) was assessed in a study using a repeatedly presented auditory oddball button-press task. A dose (5mg/kg body-weight) of either caffeine or placebo lactose, dissolved in a cup of decaffeinated coffee, was administered double-blindly to coffee drinkers who had abstained from coffee for 24hrs, with the presentation order of the sessions counterbalanced and separated by 2–4 weeks. The caffeine-treatment ...

  1. Factorial Structure of a Measure of Acculturation in a Puerto Rican Population.

    Science.gov (United States)

    De Leon, Brunilda; Mendez, Serafin

    1996-01-01

    The psychometric characteristics of the Cultural Life Style Inventory were studied with a sample of 402 Puerto Rican college students. Factor analysis revealed high factorial stability for Puerto Ricans. Similarities and differences with a previously studied Mexican American population are discussed. (SLD)

  2. On summary measure analysis of linear trend repeated measures data: performance comparison with two competing methods.

    Science.gov (United States)

    Vossoughi, Mehrdad; Ayatollahi, S M T; Towhidi, Mina; Ketabchi, Farzaneh

    2012-03-22

    The summary measure approach (SMA) is sometimes the only applicable tool for the analysis of repeated measurements in medical research, especially when the number of measurements is relatively large. This study aimed to describe techniques based on summary measures for the analysis of linear trend repeated measures data and then to compare performances of SMA, linear mixed model (LMM), and unstructured multivariate approach (UMA). Practical guidelines based on the least squares regression slope and mean of response over time for each subject were provided to test time, group, and interaction effects. Through Monte Carlo simulation studies, the efficacy of SMA vs. LMM and traditional UMA, under different types of covariance structures, was illustrated. All the methods were also employed to analyze two real data examples. Based on the simulation and example results, it was found that the SMA completely dominated the traditional UMA and performed convincingly close to the best-fitting LMM in testing all the effects. However, the LMM was not often robust and led to non-sensible results when the covariance structure for errors was misspecified. The results emphasized discarding the UMA which often yielded extremely conservative inferences as to such data. It was shown that summary measure is a simple, safe and powerful approach in which the loss of efficiency compared to the best-fitting LMM was generally negligible. The SMA is recommended as the first choice to reliably analyze the linear trend data with a moderate to large number of measurements and/or small to moderate sample sizes.

  3. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  4. Subjective measures of work-related fatigue in automobile factory employees.

    Science.gov (United States)

    Guo, Fu; Wang, Tianbo; Ning, Zuojiang

    2017-01-01

    Work-related fatigue is common among automobile factory employees. The purpose of this study was to assess fatigue of employees at a Chinese automobile factory. 238 employees (119 engineers and 119 workers) participated in this study. The following questionnaires were completed: demographic survey questionnaire, working condition questionnaire (WCQ), functional assessment of chronic illness therapy-fatigue (FACIT-F), subscales of multidimensional fatigue inventory (MFI), and Pittsburgh sleep quality index (PSQI). Both engineers and workers experienced fatigue. The workers (35.6 years old, SD = 6.7) generally felt more fatigue than engineers (42.6 years old, SD = 6.4). The engineers claimed to be more satisfied with the working conditions than workers. The WCQ showed good properties for assessing work-related factors, which were significantly correlated with fatigue (r = 0.568 for engineers and r = 0.639 for workers). For engineers, general fatigue was observed regularly and frequently, and for workers, physical fatigue usually had a long duration. The fatigue was significantly correlated with work-related factors, especially working environment and monotony. For workers, the duration of the work day also affected their fatigue. Some improvements to the working condition in this automobile factory should be considered.

  5. Repeatability of Lucas chamber measurements; Powtarzalnosc pomiarow za pomoca komory Lucasa

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.

    1997-12-31

    Results of investigations concerning the repeatability of the measurements carried out with Lucas chamber are presented in the report. The Lucas chamber is used for determination of radon concentration in air, and the Lucas chamber itself is measured in a laboratory stand. The repeatability of measurements is {+-}5.4% relative. The error due to instability of measuring channel gain is estimated to be 2-3% relative. (author). 5 refs, 17 figs, 5 tabs.

  6. High precision measurement of the micro-imaging system to check repeatability of precision

    International Nuclear Information System (INIS)

    Cheng Lin; Song Li; Ma Chuntao; Luo Hongxin; Wang Jie

    2010-01-01

    The beamlines slits of Shanghai Synchrotron Radiation Facility (SSRF) are required to have a repeatability of better than 1 μm. Before the slits installation, the off-line and/or on-line repeatability measurements must be conducted. A machine vision measuring system based on high resolution CCD and adjustable high magnification lens was used in this regard. A multi-level filtering method was used to treat the imaging data. After image binarization, the imaging noises were depressed effectively by using of algebraic mean filtering, statistics median filtering,and the least square filtering. Using the subtracted image between the images before and after slit movement, an average displacement of slit blades could be obtained, and the repeatability of slit could be measured, with a resolution of 0.3 μm of the measurement system. The experimental results show that this measurement system meets the requirements for non-contact measurements to the repeatability of slits. (authors)

  7. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Science.gov (United States)

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  8. Preventive maintenance measures and repeat tests on actuators

    International Nuclear Information System (INIS)

    Hueren, H.

    1990-01-01

    At Biblis Nuclear Power Station, about 1500 electrical actuators and variable speed drives of various model ranges and with various driving end speeds and actuating times are installed and about 600 of these are located in important safety engineering systems. In order to optimize the preventive maintenance measures on the drives, a data bank has been established into which are stored, in addition to the fixed type data of each drive, inter alia, statements about location of application, valve type, inspection cycle, calendar year of next maintenance, findings during inspection measures and causes of faults. Before each unit inspection, in addition to the inspection lists, the maintenance and installation records and also the associated job instructions are produced from this data processing equipment. (orig.) [de

  9. Virtual Learning Factory on VR-Supported Factory Planning

    OpenAIRE

    Weidig , Christian; Menck , Nicole; Winkes , Pascal ,; Aurich , Jan ,

    2014-01-01

    Part 13: Virtual Reality and Simulation; International audience; Learning Factories are becoming popular as tangible measures to teach engineering methods while making use of them in an industrial-like environment. Their core component is usually a factory demonstrator, users are physically working with. For factory planning such approaches can hardly be adapted, due to long lasting realization phases.To overcome this obstacle a virtual learning factory has been developed whose core component...

  10. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool - A literature review.

    Science.gov (United States)

    Kulikowski, Konrad

    2017-03-30

    Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES) is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA) approach have been reviewed in order to answer the question as to which of the UWES factorial structures displays greater validity. The originally proposed threefactor structure of the UWES has been recognized as superior in 6 studies. In further 6 studies, the UWES structure with 1 general factor has been found to be superior. In 8 studies, the authors have concluded that the one- and three-factor structures could be considered equivalent. One study has failed to confirm either the one- or three-factor structure of the UWES. These ambiguous results from studies focusing on the UWES factorial validity are puzzling because they not only indicate a lack of validity for the UWES as a measurement tool but might also challenge the whole concept of work engagement as a three-factor structure of dedication, vigor and absorption. Int J Occup Med Environ Health 2017;30(2):161-175. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  11. Do we all agree on how to measure work engagement? Factorial validity of Utrecht Work Engagement Scale as a standard measurement tool – A literature review

    Directory of Open Access Journals (Sweden)

    Konrad Kulikowski

    2017-04-01

    Full Text Available Work engagement as a predictor of health is an emerging concept in occupational science and the Utrecht Work Engagement Scale (UWES is the most popular work engagement measurement tool. However, despite its popularity, the UWES is not free from controversy concerning its factorial validity. In this paper, 21 research studies on both UWES-9 and UWES-17 factorial validity within the confirmatory factor analysis (CFA approach have been reviewed in order to answer the question as to which of the UWES factorial structures displays greater validity. The originally proposed threefactor structure of the UWES has been recognized as superior in 6 studies. In further 6 studies, the UWES structure with 1 general factor has been found to be superior. In 8 studies, the authors have concluded that the one- and three-factor structures could be considered equivalent. One study has failed to confirm either the one- or three-factor structure of the UWES. These ambiguous results from studies focusing on the UWES factorial validity are puzzling because they not only indicate a lack of validity for the UWES as a measurement tool but might also challenge the whole concept of work engagement as a three-factor structure of dedication, vigor and absorption. Int J Occup Med Environ Health 2017;30(2:161–175

  12. Is the color-octet mechanism consistent with the double J/ψ production measurement at B-factories?

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Yu [Third Military Medical University, Department of Physics, School of Biomedical Engineering, Chongqing (China); Sun, Zhan [Guizhou Minzu University, School of Science, Guiyang (China); Zhang, Hong-Fei [Third Military Medical University, Department of Physics, School of Biomedical Engineering, Chongqing (China); Chongqing University of Posts and Telecommunications, School of Science, Chongqing (China)

    2017-04-15

    Double J/ψ production in e{sup +}e{sup -} collisions involving color-octet channels are evaluated up to order α{sup 2}α{sub s}{sup 3}. Having implemented the variation of the parameters (m{sub c}, μ{sub r} and long-distance matrix elements), we found that the cross sections for producing double J/ψ at B-factories range from -0.016 to 0.245 fb, which are even much smaller than that via the color-singlet mechanism. Accordingly, this result is consistent with the measurement by the Belle and BABAR Collaborations. (orig.)

  13. Internet Factories

    NARCIS (Netherlands)

    Strijkers, R.J.

    2014-01-01

    This thesis contributes a novel concept for introducing new network technologies in network infrastructures. The concept, called Internet factories, describes the methodical process to create and manage application-specific networks from application programs, referred to as Netapps. An Internet

  14. Internet factories

    NARCIS (Netherlands)

    Strijkers, R.J.

    2014-01-01

    This thesis contributes a novel concept for introducing new network technologies in network infrastructures. The concept, called Internet factories, describes the methodical process to create and manage application-specific networks from application programs, referred to as Netapps. An Internet

  15. Factory physics

    CERN Document Server

    Hopp, Wallace J.

    2011-01-01

    After a brief introductory chapter, "Factory Physics 3/e" is divided into three parts: I - The Lessons of History; II - Factory Physics; and III - Principles in Practice. The scientific approach to manufacturing and supply chain management, developed in Part II, is unique to this text. No other text or professional book provides a rigorous, principles-based foundation for manufacturing management. The Third Edition offers tighter connections between Lean Manufacturing, MRP/ERP, Six Sigma, Supply Chain Management, and Factory Physics. In addition to enhancing the historical overview of how these systems evolved, the authors show explicitly how users can achieve Lean Manufacturing objectives (faster response, less inventory) using the integration aspects of MRP/ERP/SCM systems along with the variance analysis methods of Six Sigma. Factory Physics provides the overarching framework that coordinates all of these initiatives into a single-focused strategy.

  16. Baby Factory

    African Journals Online (AJOL)

    Prof

    2018-01-24

    Jan 24, 2018 ... mass media have the power to easily propagate ideas on social change ... issue of 'baby factory' is becoming everyday news affecting the right of ... according to recent mass media reports, teenage girls and young women are.

  17. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  18. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind

  19. Phi factories

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Plans for 'phi factories' gathered momentum with a recent workshop at UCLA. These machines, high luminosity electron-positron colliders working near the phi resonance at 1020 MeV, have been proposed at Laboratories in Europe, the US, Japan and the USSR

  20. Formatting data files for repeated-measures analyses in SPSS: Using the Aggregate and Restructure procedures

    Directory of Open Access Journals (Sweden)

    Gyslain Giguère

    2006-03-01

    Full Text Available In this tutorial, we demonstrate how to use the Aggregate and Restructure procedures available in SPSS (versions 11 and up to prepare data files for repeated-measures analyses. In the first two sections of the tutorial, we briefly describe the Aggregate and Restructure procedures. In the final section, we present an example in which the data from a fictional lexical decision task are prepared for analysis using a mixed-design ANOVA. The tutorial demonstrates that the presented method is the most efficient way to prepare data for repeated-measures analyses in SPSS.

  1. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  2. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    Science.gov (United States)

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  3. Convergence of repeated quantum nondemolition measurements and wave-function collapse

    International Nuclear Information System (INIS)

    Bauer, Michel; Bernard, Denis

    2011-01-01

    Motivated by recent experiments on quantum trapped fields, we give a rigorous proof that repeated indirect quantum nondemolition (QND) measurements converge to the collapse of the wave function as predicted by the postulates of quantum mechanics for direct measurements. We also relate the rate of convergence toward the collapsed wave function to the relative entropy of each indirect measurement, a result which makes contact with information theory.

  4. Smart Factory

    DEFF Research Database (Denmark)

    Bilberg, Arne; Radziwon, Agnieszka; Grube Hansen, David

    2017-01-01

    their innovation and competitive advantage by focusing at their competences, strengths and opportunities. The project suggests innovative solutions and business models through collaboration and use of new technologies. In the Smart Factory, SMEs should be able to collaborate on new products, markets and production......, and to target their challenges and ensure sustainable growth and business in these enterprises. Therefore the focus of the Smart Factory project was to support the growth and sustainable development of the small and medium sized manufacturing industry in Denmark. The project focused on SMEs and how to improve......A large part of Danish Industry is based on Small and Medium Sized Enterprises (SMEs), which account for –99% of the companies in Denmark and about two third of the job positions (source: statistikbanken.dk) . That is why, it is so important also to focus research and development at SMEs...

  5. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  6. Use of the Counseling Center Assessment of Psychological Symptoms 62 (CCAPS-62) as a Repeated Measure

    Science.gov (United States)

    Ghosh, Arpita; Rieder Bennett, Sara; Martin, Juanita K.

    2018-01-01

    The purpose of this initial, exploratory study was to examine the utility of the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62) as a repeated measure tool at one university counseling center. This study investigated whether clients engaged in individual counseling changed in symptomology while in treatment and when (e.g.,…

  7. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction

    DEFF Research Database (Denmark)

    Paige, Ellie; Barrett, Jessica; Pennells, Lisa

    2017-01-01

    The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data...

  8. Counterbalancing and Other Uses of Repeated-Measures Latin-Square Designs: Analyses and Interpretations.

    Science.gov (United States)

    Reese, Hayne W.

    1997-01-01

    Recommends that when repeated-measures Latin-square designs are used to counterbalance treatments across a procedural variable or to reduce the number of treatment combinations given to each participant, effects be analyzed statistically, and that in all uses, researchers consider alternative interpretations of the variance associated with the…

  9. Parsimonious Structural Equation Models for Repeated Measures Data, with Application to the Study of Consumer Preferences

    Science.gov (United States)

    Elrod, Terry; Haubl, Gerald; Tipps, Steven W.

    2012-01-01

    Recent research reflects a growing awareness of the value of using structural equation models to analyze repeated measures data. However, such data, particularly in the presence of covariates, often lead to models that either fit the data poorly, are exceedingly general and hard to interpret, or are specified in a manner that is highly data…

  10. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  11. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  12. Near-Peer Teaching in Paramedic Education: A Repeated Measures Design

    Science.gov (United States)

    Williams, Brett; Nguyen, David

    2017-01-01

    The transition of the Australian paramedic discipline from vocation education and training to the higher education sector has seen a sharp rise in interest in near-peer teaching (NPT). The objective of this study was to examine satisfaction levels of NPT over one academic semester among undergraduate paramedic students. A repeated measured design…

  13. Neutrino factories

    International Nuclear Information System (INIS)

    Dydak, F.

    2002-01-01

    The discovery of neutrino oscillations marks a major milestone in the history of neutrino physics, and opens a window to what lies beyond the Standard Model. Many current and forthcoming experiments will answer open questions; however, a major step forward, up to and possibly including CP violation in the neutrino mixing matrix, will be offered by the neutrino beams from a neutrino factory. The neutrino factory is a new concept for producing neutrino beams of unprecedented quality in terms of intensity, flavour composition, and precision of the beam parameters. These beams enable the exploration of otherwise inaccessible domains in neutrino oscillation physics by exploiting baselines of planetary dimensions. Suitable detectors pose formidable challenges but seem within reach with only moderate extrapolations from existing technologies. Although the main physics attraction of the neutrino factory is in the area of neutrino oscillations, an interesting spectrum of further opportunities ranging from high-precision, high-rate neutrino scattering to physics with high-intensity stopped muons comes with it

  14. The structure of harassment and abuse in the workplace: a factorial comparison of two measures.

    Science.gov (United States)

    Fendrich, Michael; Woodword, Paul; Richman, Judith A

    2002-08-01

    The structures of two measures examining negative experiences in the workplace, one focusing primarily on sexual harassment (SEQ) and one focusing on workplace abuse (GWA), were examined in detail. This article investigated whether the five subscales for the relatively unexplored measure (GWA) are reliably measured by a single underlying construct. It also investigated whether the two workplace-based measures are distinct but related constructs and the consistency of their factor structure across genders. Using a large and diverse organizational survey derived from a Midwestern university, analyses supported the distinctiveness of the two measures and showed that the factor structures for the two constructs were remarkably similar across genders. Analyses also suggested that indices of extreme behavior within each of the constructs were not reliably measured. The findings have important implications for data collection strategies in research focused on negative workplace experiences. This study provides considerable support for the continued use of both measures in research investigating the impact of adverse workplace environment on health.

  15. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  16. The factorial structure of job-related affective well-being: Polish adaptation of the Warr's measure.

    Science.gov (United States)

    Mielniczuk, Emilia; Łaguna, Mariola

    2018-02-16

    The first aim of the study reported in this article was to test the factorial structure of job-related affect in a Polish sample. The second aim was to develop the Polish adaptation of the Warr's job-related affective well-being measure published in 1990, which is designed to assess 4 types of affect at work: anxiety, comfort, depression, enthusiasm. A longitudinal study design with 2 measurement times was used for verifying the psychometric properties of the Polish version of the measure. The final sample consisted of 254 Polish employees from different professions. Participants were asked to fill in a set of questionnaires consisting of measures capturing job-related affective well-being, mood, and turnover intention. The first step of analysis was to test the theoretically-based structure of the job-related affective well-being measure in a Polish sample. The confirmatory factor analysis revealed that a 4-factor model best describes the structure of the measure in comparison to 5 alternative models. Next, reliability of this measure was assessed. All scales achieved good internal consistency and acceptable test-retest reliability after 2 weeks. Finally, the convergent and discriminant validity as well as the criterion and predictive validity of all job-related affective well-being scales was confirmed, based on correlations between job-related affect and mood as well as turnover intention. The results suggest that the Polish adaptation of Warr's job-related affective well-being measure can be used by scientists as well as by practitioners who aim at assessing 4 types of affective well-being at a work context. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. Coaxial wire impedance measurements of BPM buttons for the PEP-II B- factory

    International Nuclear Information System (INIS)

    Corlett, J.N.

    1995-09-01

    The coaxial wire impedance measurement uses a conducting rod placed along the beam axis in the vacuum chamber, forming the center conductor in a coaxial line system. Tapers at either end of this section allow for smooth impedance transformation from the 50Ω lines used in common microwave measurement equipment, to the characteristic impedance of the vacuum chamber and center conductor, typically around 200Ω. RF and microwave absorptive material placed in the ends of the vacuum chamber and in the impedance matching tapers minimizes reflections which cause trapped modes within the apparatus, allowing measurements to be made above the traveling-wave cut-off frequency of the vacuum vessel (typically 2.5 - 3.0 GHz for PEP-II). A smooth vessel of the same cross-section as that containing the device under test is used in a reference measurement Resonances within the apparatus are difficult to avoid completely and require careful placing of absorptive material, manufacture of test and reference chambers, and assembly of apparatus

  18. First Measurements at the Daphne $\\phi$-Factory with the DEAR

    CERN Document Server

    Augsburger, M A; Egger, J P; Gartner, B; Guaraldo, C; Iliescu, M A; King, R; Lauss, B; Petrascu, C; Zmeskal, J

    2000-01-01

    The relevant background for the DEAR experiment - low-energy Xrays and ionizing particles - present in the DEAR interaction region of the DAPHNE e^+e^- collider was inves-tigated using the first stage DEAR setup and CCD detectors. $9 An extensive Monte Carlo simulation was performed for the present setup and beam conditions. Good quantitative agreement between measurements and simulation was achieved. This is a confirmation that, with respect to the expected $9 background, which gives an important contribution to the statistical precision of the experiment, the configuration chosen to measure the strong interaction shift and width in kaonic hydrogen and kaonic deuterium can indeed reach the $9 planned level of accuracy.

  19. Meson factories

    International Nuclear Information System (INIS)

    Dicello, J.F.; Zaider, M.; Bradbury, J.N.

    1979-01-01

    Technological improvements in accelerator design in the 1960's resulted in the capability to develop medium-energy proton accelerators with beam intensities of almost 1 mA. These beams are able to produce fluxes of secondary particles, including pions, muons, neutrinos, and neutrons, which are as much as 10,000 times as intense as those previously available. Those machines built for optimum meson production are commonly called meson factories. The characteristics of these facilities are reviewed, and the present programs in applied research, and some potential areas of future work are discussed

  20. Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

    Directory of Open Access Journals (Sweden)

    Adrian F. Ocneanu

    2017-01-01

    Full Text Available Purpose. Myocardial blood flow (MBF quantification with Rb82 positron emission tomography (PET is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic Rb82 PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1 blood-pool versus uptake region sampled input function (Blood/Uptake-ROI, (2 dual spillover correction (SOC-On/Off, (3 right blood correction (RBC-On/Off, (4 arterial blood transit delay (Delay-On/Off, and (5 distribution volume (DV constraint (Global/Regional-DV. Repeatability of MBF, stress/rest myocardial flow reserve (MFR, and stress/rest MBF difference (ΔMBF was assessed using nonparametric reproducibility coefficients (RPCnp = 1.45 × interquartile range. Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPCnp = 0.21 mL/min/g (15.8%. Corresponding MFR and ΔMBF RPCnp were 0.42 (20.2% and 0.24 mL/min/g (23.5%. MBF repeatability improved with SOC-On at stress (p<0.001 and tended to improve with RBC-Off at both rest and stress (p<0.08. DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.

  1. Joint modelling of repeated measurement and time-to-event data: an introductory tutorial.

    Science.gov (United States)

    Asar, Özgür; Ritchie, James; Kalra, Philip A; Diggle, Peter J

    2015-02-01

    The term 'joint modelling' is used in the statistical literature to refer to methods for simultaneously analysing longitudinal measurement outcomes, also called repeated measurement data, and time-to-event outcomes, also called survival data. A typical example from nephrology is a study in which the data from each participant consist of repeated estimated glomerular filtration rate (eGFR) measurements and time to initiation of renal replacement therapy (RRT). Joint models typically combine linear mixed effects models for repeated measurements and Cox models for censored survival outcomes. Our aim in this paper is to present an introductory tutorial on joint modelling methods, with a case study in nephrology. We describe the development of the joint modelling framework and compare the results with those obtained by the more widely used approaches of conducting separate analyses of the repeated measurements and survival times based on a linear mixed effects model and a Cox model, respectively. Our case study concerns a data set from the Chronic Renal Insufficiency Standards Implementation Study (CRISIS). We also provide details of our open-source software implementation to allow others to replicate and/or modify our analysis. The results for the conventional linear mixed effects model and the longitudinal component of the joint models were found to be similar. However, there were considerable differences between the results for the Cox model with time-varying covariate and the time-to-event component of the joint model. For example, the relationship between kidney function as measured by eGFR and the hazard for initiation of RRT was significantly underestimated by the Cox model that treats eGFR as a time-varying covariate, because the Cox model does not take measurement error in eGFR into account. Joint models should be preferred for simultaneous analyses of repeated measurement and survival data, especially when the former is measured with error and the association

  2. Solid deuterium and UCN factory: application to the neutron electric dipole moment measurement

    CERN Document Server

    Serebrov, A P

    2000-01-01

    Present experiments which search for an electric dipole moment (EDM) of the neutron use ultra-cold neutrons (UCN) and are limited by counting statistics. One way to solve this problem is to improve the source of UCN. The present article briefly reviews two possibilities which employ solid deuterium at the temperature of liquid helium. The possibility of installing a solid deuterium UCN source at the FRM-II reactor and at spallation neutron sources at PSI, LANL and KEK is discussed. An increase of the UCN density up to the level of 10 sup 3 -10 sup 4 cm sup - sup 3 is expected. Compared to existing sources, this corresponds to an improvement by two to three orders of magnitude. Such experimental facilities will make it possible to improve measurements of the EDM of the neutron down to the level of 10 sup - sup 2 sup 7 e cm.

  3. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  4. Comparability and repeatability of three commonly used methods for measuring endurance capacity.

    Science.gov (United States)

    Baxter-Gilbert, James; Mühlenhaupt, Max; Whiting, Martin J

    2017-12-01

    Measures of endurance (time to exhaustion) have been used to address a wide range of questions in ecomorphological and physiological research, as well as being used as a proxy for survival and fitness. Swimming, stationary (circular) track running, and treadmill running are all commonly used methods for measuring endurance. Despite the use of these methods across a broad range of taxa, how comparable these methods are to one another, and whether they are biologically relevant, is rarely examined. We used Australian water dragons (Intellagama lesueurii), a species that is morphologically adept at climbing, swimming, and running, to compare these three methods of endurance and examined if there is repeatability within and between trial methods. We found that time to exhaustion was not highly repeatable within a method, suggesting that single measures or a mean time to exhaustion across trials are not appropriate. Furthermore, we compared mean maximal endurance times among the three methods, and found that the two running methods (i.e., stationary track and treadmill) were similar, but swimming was distinctly different, resulting in lower mean maximal endurance times. Finally, an individual's endurance rank was not repeatable across methods, suggesting that the three endurance trial methods are not providing similar information about an individual's performance capacity. Overall, these results highlight the need to carefully match a measure of performance capacity with the study species and the research questions being asked so that the methods being used are behaviorally, ecologically, and physiologically relevant. © 2018 Wiley Periodicals, Inc.

  5. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  6. Intelligence is in the eye of the beholder: investigating repeated IQ measurements in forensic psychiatry.

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-05-01

    A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were computed, and each IQ score was categorized. Additionally, t-tests and regression analyses were performed. Differences of 10 points or more were found in 66% of the cases comparing WAIS-III with RAVEN scores. Fisher's exact test revealed differences between two WAIS-III scores and the WAIS categories. The WAIS-III did not predict other IQs (WAIS or RAVEN) in participants with intellectual disability. This study showed that stability or interchangeability of scores is lacking, especially in individuals with intellectual disability. Caution in interpreting IQ scores is therefore recommended, and the use of the unitary concept of IQ should be discouraged. © 2014 John Wiley & Sons Ltd.

  7. A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

    International Nuclear Information System (INIS)

    MacLeod, Chelsea L.; Ivezić, Željko; Becker, Andrew C.; Anderson, Scott F.; Sesar, Branimir; De Vries, Wim; Kochanek, Christopher S.; Kelly, Brandon C.; Lupton, Robert H.; Hall, Patrick B.; Richards, Gordon T.; Schneider, Donald P.

    2012-01-01

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining ∼25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 Å to 6000 Å. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of ∼5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

  8. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  9. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  10. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  11. Kaon factories

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1983-03-01

    Kaon factories would provide beams 100-1000 times more intense than those available from present accelerators in the 10-30 GeV range. More intense or cleaner secondary beams of kaons, antiprotons and neutrinos would be of particular interest for high precision experiments and studies of rare processes in both particle and nuclear physics, e.g. symmetry violations in K-decay, neutrino scattering, meson and baryon spectroscopy, hypernuclei, exotic atoms, K + studies of nuclear density and resonance propagation in nuclei. The various accelerators proposed include both fast-cycling synchrotrons providing 100 μA proton beams at 15 to 32 GeV and superconducting isochronous ring cyclotrons giving 100-400 μA at up to 15 GeV. This paper describes these designs and the various technical problems associated with them

  12. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  13. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  14. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  15. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    International Nuclear Information System (INIS)

    Kroner, E; Arzt, E; Maboudian, R

    2009-01-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  16. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  17. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  18. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  19. Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.

    Science.gov (United States)

    Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E

    2018-01-01

    The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established

  20. REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

    Energy Technology Data Exchange (ETDEWEB)

    Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa [Spitzer Science Center, California Institute of Technology, 1200 E California Boulevard, Mail Code 314-6, Pasadena, CA 91125 (United States); Buzasi, Derek [Department of Chemistry and Physics, Florida Gulf Coast University, Fort Myers, FL 33965 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Diamond-Lowe, Hannah; Stevenson, Kevin B. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S Ellis Avenue, Chicago, IL 60637 (United States); Evans, Thomas M. [School of Physics, University of Exeter, EX4 4QL Exeter (United Kingdom); Morello, G. [Department of Physics and Astronomy, University College London, Gower Street, WC1 E6BT (United Kingdom); Wong, Ian, E-mail: ingalls@ipac.caltech.edu [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-08-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble,  5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

  1. Validation of Repeated Endothelial Function Measurements Using EndoPAT in Stroke

    DEFF Research Database (Denmark)

    Hansen, Aina S; Butt, Jawad H; Holm-Yildiz, Sonja

    2017-01-01

    BACKGROUND: Decreased endothelial function (EF) may be a prognostic marker for stroke. Measuring pharmacological effects on EF may be of interest in the development of personalized medicine for stroke prevention. In this study, we assessed the reliability of repeated EF measurements using a pulse......%, mean age 35.85 ± 3.47 years) and 21 stroke patients (men 52%, mean age 66.38 ± 2.85 years, and mean NIHSS 4.09 ± 0.53) under standardized conditions. EF was measured as the reactive hyperemia index (RHI), logarithm of RHI (lnRHI), and Framingham RHI (fRHI). Measurements were separated by 1.5 and 24 h...

  2. KAON factories

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1989-09-01

    Proposals for high intensity proton synchrotrons (typically providing 100 μA (6 x 10 14 p/s)) at 30 GeV have been made in Canada, Europe, Japan, the USA and the USSR. These beams would be roughly 100 times more intense than those available now and would yield equivalent increases in the fluxes of secondary particles (kaons, pions, muons, antiprotons, hyperons and neutrinos) - or cleaner beams for a smaller increase in flux. The ability to investigate rare processes on the precision frontier opens new avenues to fundamental questions in both particle and nuclear physics, complementary to traditional approaches via the energy frontier. The demand for higher currents has led to novel features in many of the accelerator designs: asymmetric magnet cycles, avoidance of transition crossing, separate collector and stretcher rings, three-dimensional beam painting at injection, bucket-to-bucket beam transfer, perpendicular biassing of microwave ferrite in the rf tuners, the use of Siberian Snakes to preserve polarization, and the addition of a pre-septum to make slow extraction >99.8% efficient. Other characteristic features include rapid cycling rates, booster stages, H - injection, low impedance enclosures, powerful feedback systems for control of beam instabilities and beam loading, and local collimation systems for handling beam loss. This paper reviews the general features of kaon factory accelerator design and the status of the various proposals

  3. Education for patients with chronic kidney disease in Taiwan: a prospective repeated measures study.

    Science.gov (United States)

    Yen, Miaofen; Huang, Jeng-Jong; Teng, Hsiu-Lan

    2008-11-01

    To investigate the physical, knowledge and quality of life outcomes of an educational intervention for patients with early stage chronic kidney disease. A comprehensive predialysis education care team can be effective in slowing the progression of chronic kidney disease. A single group repeated measures design was used to evaluate the effects of the intervention. Participants were recruited through health department community health screen data banks. A predialysis, team-delivered educational intervention covering renal function health care, dietary management of renal function and the effects of Chinese herb medication on renal function was designed and implemented. Data were collected at baseline, six and 12 months. Study outcomes included physical indicators, knowledge (renal function protection, use of Chinese herbs and renal function and diet) and quality of life. Data were analysed using repeated measure anova to test for change over time in outcome variables. Sixty-six persons participated in this study. The predialysis educational intervention showed significant differences at the three time points in overall knowledge scores, waist-hip ratio, body mass index and global health status. Knowledge measures increased at month 6 and decreased at month 12. The primary indicator of renal function, glomerular filtration rate, remained stable throughout the 12 months of follow-up, despite the relatively older mean age of study participants. A predialysis education care team can provide effective disease-specific knowledge and may help retard deterioration of renal function in persons with early-stage chronic kidney disease. The intervention dose may need to be repeated every six months to maintain knowledge effects. A predialysis educational program with disease-specific knowledge and information is feasible and may provide positive outcomes for patients. Topics on the uses of Chinese herbs should be included for people who are likely to use alternative therapies.

  4. Characterisation and measurement of signals generated by DVB-H 'gap-filler' repeaters

    International Nuclear Information System (INIS)

    Baldini, M.; Barellini, A.; Bogi, L.; Licitra, G.; Silvi, A. M.; Zari, A.

    2009-01-01

    DVB-H (Digital Video Broadcasting Hand-held) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains. (authors)

  5. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  6. Repeated absolute gravity measurements for monitoring slow intraplate vertical deformation in Western Europe

    Science.gov (United States)

    Van Camp, M. J.; de Viron, O.; Scherneck, H.; Hinzen, K. G.; Williams, S. D.; Lecocq, T.; Quinif, Y.; Camelbeeck, T.

    2011-12-01

    In continental plate interiors, ground surface movements are at the limit of the noise level and close to or below the accuracy of current geodetic techniques. Absolute gravity measurements are valuable to quantify slow vertical movements, as this instrument is drift free and, unlike GPS, independent of the terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformation in the area. The AG measurements, repeated once or twice a year, can resolve elusive gravity changes with a precision better than 3.7 nm/s2/yr (95% confidence interval) after 11 years, even in difficult conditions. After 8-15 years (depending on the station), we find that the gravity rates of change lie in the [-3.1, 8.1] nm/s2/yr interval and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. After correcting for the GIA, the inferred gravity rates and consequently, the vertical land movements, reduce to zero within the uncertainty level at all stations except Jülich (due to man-induced subsidence) and Sohier (possibly, an artefact due to the shortness of the time series at that station).

  7. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    with first year seed crops using three sowing rates and three spring nitrogen (N) application rates. PLSR models were developed for each year and showed correlation coefficients of 0.71, 0.76, and 0.92, respectively. Regression coefficients showed in these experiments that the optimum time for canopy...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development......Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...

  8. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate b...

  9. Analyzing repeated measures data on individuals nested within groups: accounting for dynamic group effects.

    Science.gov (United States)

    Bauer, Daniel J; Gottfredson, Nisha C; Dean, Danielle; Zucker, Robert A

    2013-03-01

    Researchers commonly collect repeated measures on individuals nested within groups such as students within schools, patients within treatment groups, or siblings within families. Often, it is most appropriate to conceptualize such groups as dynamic entities, potentially undergoing stochastic structural and/or functional changes over time. For instance, as a student progresses through school, more senior students matriculate while more junior students enroll, administrators and teachers may turn over, and curricular changes may be introduced. What it means to be a student within that school may thus differ from 1 year to the next. This article demonstrates how to use multilevel linear models to recover time-varying group effects when analyzing repeated measures data on individuals nested within groups that evolve over time. Two examples are provided. The 1st example examines school effects on the science achievement trajectories of students, allowing for changes in school effects over time. The 2nd example concerns dynamic family effects on individual trajectories of externalizing behavior and depression. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  10. Analyzing Repeated Measures Marginal Models on Sample Surveys with Resampling Methods

    Directory of Open Access Journals (Sweden)

    James D. Knoke

    2005-12-01

    Full Text Available Packaged statistical software for analyzing categorical, repeated measures marginal models on sample survey data with binary covariates does not appear to be available. Consequently, this report describes a customized SAS program which accomplishes such an analysis on survey data with jackknifed replicate weights for which the primary sampling unit information has been suppressed for respondent confidentiality. First, the program employs the Macro Language and the Output Delivery System (ODS to estimate the means and covariances of indicator variables for the response variables, taking the design into account. Then, it uses PROC CATMOD and ODS, ignoring the survey design, to obtain the design matrix and hypothesis test specifications. Finally, it enters these results into another run of CATMOD, which performs automated direct input of the survey design specifications and accomplishes the appropriate analysis. This customized SAS program can be employed, with minor editing, to analyze general categorical, repeated measures marginal models on sample surveys with replicate weights. Finally, the results of our analysis accounting for the survey design are compared to the results of two alternate analyses of the same data. This comparison confirms that such alternate analyses, which do not properly account for the design, do not produce useful results.

  11. Tectonic, Climatic and Anthropogenic Vertical Land Movements in Western Europe by Repeated Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M. J.; de Viron, O.; Lecocq, T.; Hinzen, K. G.; Quinif, Y.; Williams, S. D.; Camelbeeck, T.

    2010-12-01

    In continental plate interiors, tectonic deformations are small and the associated ground surface movements remain close to or below the accuracy of current geodetic techniques, and at the limit of the noise level. An absolute gravimeter is an appropriate tool to quantify slow vertical movements, as this instrument, based on length and time standards, is drift free and does not depend on any terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformations in the area. After 7-13 years (depending on the station), we find evidence that the movements are no larger than a few millimeter per year and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. This demonstrates the importance of precisely modeling the GIA effects in order to investigate intraplate tectonic deformations at the sub-millimeter level. This study also shows that AG measurements, repeated once or twice a year, can resolve vertical velocities at the 1.0 mm/yr level after 10 years, even in difficult conditions, provided that the gravimeter is carefully maintained.

  12. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  13. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  14. Theoretical repeatability assessment without repetitive measurements in gradient high-performance liquid chromatography.

    Science.gov (United States)

    Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki

    2016-07-08

    This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A Modified Jonckheere Test Statistic for Ordered Alternatives in Repeated Measures Design

    Directory of Open Access Journals (Sweden)

    Hatice Tül Kübra AKDUR

    2016-09-01

    Full Text Available In this article, a new test based on Jonckheere test [1] for  randomized blocks which have dependent observations within block is presented. A weighted sum for each block statistic rather than the unweighted sum proposed by Jonckheereis included. For Jonckheere type statistics, the main assumption is independency of observations within block. In the case of repeated measures design, the assumption of independence is violated. The weighted Jonckheere type statistic for the situation of dependence for different variance-covariance structure and the situation based on ordered alternative hypothesis structure of each block on the design is used. Also, the proposed statistic is compared to the existing test based on Jonckheere in terms of type I error rates by performing Monte Carlo simulation. For the strong correlations, circular bootstrap version of the proposed Jonckheere test provides lower rates of type I error.

  16. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  17. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Phypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  18. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  19. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    Science.gov (United States)

    Surgenor, Paul Wg; Freeman, Joan; O'Connor, Cindy

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client's suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook. A quasi-experimental, pre-test post-test repeated measures design was employed. A questionnaire assessing self-esteem, depression, and positive and negative suicidal ideation was administered to the same participants pre- and post- therapy facilitating paired responses. Multiple analysis of variance and paired-samples t-tests were conducted to establish whether therapy using the PH-SIM had a significant effect on the clients' negative and positive outlook. Analyses revealed a statistically significant effect of therapy for depression, negative suicidal ideation, self-esteem, and positive suicidal ideation. Negative outlook was significantly lower after therapy and positive outlook significantly higher. The decreased negative outlook and increased positive outlook following therapy provide some support for the proposed model in fulfilling its role, though additional research is required to establish the precise role of the intervention model in achieving this.

  20. Psychosocial outcomes of Hong Kong Chinese diagnosed with acute coronary syndromes: a prospective repeated measures study.

    Science.gov (United States)

    Chan, Dominic S K; Chau, Janita P C; Chang, Anne M

    2007-08-01

    Western studies have suggested that emotional stress and distress impacted on the morbidity and mortality in people following acute coronary events. Symptoms of anxiety and depression have been associated with re-infarction and death, prolonged recovery and disability and depression may precipitate the client's low self-esteem. This study examined perceived anxiety, depression and self-esteem of Hong Kong Chinese clients diagnosed with acute coronary syndrome (ACS) over a 6-month period following hospital admission. To examine: A prospective, repeated measures design with measures taken on two occasions over a 6-month period; (1) within the 1st week of hospital admission following the onset of ACS and (2) at 6 months follow up. Convenient sample of 182 voluntary consented clients admitted with ACS to a major public hospital in Hong Kong who could communicate in Chinese, complete questionnaires, cognitive intact, and were haemodynamically stable and free from acute chest pain at the time of interview. Baseline data were obtained within 1 week after hospital admission. The follow-up data was collected 6 months after hospital discharge. The Chinese version of the Hospital Anxiety and Depression Scale (HADS), State Self-esteem Scale (SSES), and Rosenberg's Self-Esteem Scale (RSES) were used to assess anxiety and depression, state self-esteem, and trait self-esteem, respectively. Findings suggested gender differences in clients' perception in anxiety, depression and self-esteem. Improvements in clients' perception of these variables were evident over the 6-month period following their acute coronary events. The study confirmed the western notion that psychosocial problems are common among coronary clients and this also applies to Hong Kong Chinese diagnosed with ACS. Further studies to explore effective interventions to address these psychosocial issues are recommended.

  1. Effect of hip braces on brake response time: Repeated measures designed study.

    Science.gov (United States)

    Dammerer, Dietmar; Waidmann, Cornelia; Huber, Dennis G; Krismer, Martin; Haid, Christian; Liebensteiner, Michael C

    2017-08-01

    The question whether or not a patient with a hip brace should drive a car is of obvious importance because the advice given to patients to resume driving is often anecdotal as few scientific data are available on this specific subject. To assess driving ability (brake response time) with commonly used hip braces. Repeated measures design. Brake response time was assessed under six conditions: (1) without a brace (control), (2) with a typical postoperative hip brace with adjustable range of motion and the settings: unrestricted, (3) flexion limited to 70°, (4) extension blocked at 20° hip flexion, (5) both flexion and extension limited (20°/70°) and (6) an elastic hip bandage. Brake response time was assessed using a custom-made driving simulator as used in previous studies. The participants were a convenience sample of able-bodied participants. A total of 70 participants (35 women and 35 men) participated in our study. Mean age was 31.1 (standard deviation: 10.6; range: 21.7-66.4) years. A significant within-subject effect for brake response time was found ( p = 0.009), but subsequent post hoc analyses revealed no significant differences between control and the other settings. Based on our findings, it does not seem mandatory to recommend driving abstinence for patients wearing a hip orthosis. We suggest that our results be interpreted with caution, because (1) an underlying pathological hip condition needs to be considered, (2) the ability to drive a car safely is multifactorial and brake response time is only one component thereof and (3) brake response time measurements were performed only with healthy participants. Clinical relevance Hip braces are used in the context of joint-preserving and prosthetic surgery of the hip. Therefore, clinicians are confronted with the question whether to allow driving a car with the respective hip brace or not. Our data suggest that hip braces do not impair brake response time.

  2. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  3. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Science.gov (United States)

    Reed, Katharine; Wood, Carly; Barton, Jo; Pretty, Jules N; Cohen, Daniel; Sandercock, Gavin R H

    2013-01-01

    Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run) and self-reported physical activity (PAQ-A) in 11 and 12 year olds (n = 75). Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE) and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74), = 12.2, pself-esteem following exercise but there was no condition by exercise interaction (F (1,74), = 0.13, p = 0.72). There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04) between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55). Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  4. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    Science.gov (United States)

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations

  5. Context matters! sources of variability in weekend physical activity among families: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Robert J. Noonan

    2017-04-01

    Full Text Available Abstract Background Family involvement is an essential component of effective physical activity (PA interventions in children. However, little is known about the PA levels and characteristics of PA among families. This study used a repeated measures design and multiple data sources to explore the variability and characteristics of weekend PA among families. Methods Families (including a ‘target’ child aged 9–11 years, their primary caregiver(s and siblings aged 6–8 years were recruited through primary schools in Liverpool, UK. Participants completed a paper-based PA diary and wore an ActiGraph GT9X accelerometer on their left wrist for up to 16 weekend days. ActiGraph.csv files were analysed using the R-package GGIR version 1.1–4. Mean minutes of moderate-to-vigorous PA (MVPA for each weekend of measurement were calculated using linear mixed models, and variance components were estimated for participant (inter-individual, weekend of measurement, and residual error (intra-individual. Intraclass correlation coefficients (ICC were calculated from the proportion of total variance accounted for by inter-individual sources, and used as a measure of reliability. Diary responses were summed to produce frequency counts. To offer contextual insight into weekend PA among family units, demographic, accelerometer, and diary data were combined to form two case studies representative of low and high active families. Results Twenty-five participants from 7 families participated, including 7 ‘target’ children (mean age 9.3 ± 1.1 years, 4 boys, 6 siblings (mean age 7.2 ± 0.7 years; 4 boys and 12 adults (7 mothers and 5 fathers. There was a high degree of variability in target children’s (ICC = 0.55, siblings (ICC = 0.38, and mothers’ MVPA (ICC = 0.58, but not in fathers’ MVPA (ICC = 0.83. Children’s weekend PA was mostly unstructured in nature and undertaken with friends, whereas a greater proportion of parents’ weekend

  6. Fractional factorial plans

    CERN Document Server

    Dey, Aloke

    2009-01-01

    A one-stop reference to fractional factorials and related orthogonal arrays.Presenting one of the most dynamic areas of statistical research, this book offers a systematic, rigorous, and up-to-date treatment of fractional factorial designs and related combinatorial mathematics. Leading statisticians Aloke Dey and Rahul Mukerjee consolidate vast amounts of material from the professional literature--expertly weaving fractional replication, orthogonal arrays, and optimality aspects. They develop the basic theory of fractional factorials using the calculus of factorial arrangements, thereby providing a unified approach to the study of fractional factorial plans. An indispensable guide for statisticians in research and industry as well as for graduate students, Fractional Factorial Plans features: * Construction procedures of symmetric and asymmetric orthogonal arrays. * Many up-to-date research results on nonexistence. * A chapter on optimal fractional factorials not based on orthogonal arrays. * Trend-free plans...

  7. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  8. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  9. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  10. Repeatability of measures of inflammatory cell number in bronchial biopsies in atopic asthma

    NARCIS (Netherlands)

    Sont, J. K.; Willems, L. N.; Evertse, C. E.; Hooijer, R.; Sterk, P. J.; van Krieken, J. H.

    1997-01-01

    Airway pathology is increasingly considered to be a major outcome in asthma research. The aim of this study was to examine the intra-observer, within-section and between-biopsy repeatability, together with the implications for statistical power of a computerized quantitative analysis of inflammatory

  11. Neutrino Factory: status and prospects

    International Nuclear Information System (INIS)

    Long, K.

    2011-01-01

    The properties of the neutrino provide a unique window on physics beyond that described by the Standard Model. The study of sub-leading effects in neutrino oscillations has begun with the race to measure θ 13 consensus is emerging within the international community that a novel neutrino source is required to allow sensitive searches for leptonic CP violation to be carried out and the neutrino mass-hierarchy to be determined. The Neutrino Factory, in which intense neutrino beams are produced from the decay of muons, has been shown to out-perform the other proposed facilities. The physics case for the Neutrino Factory will be reviewed and the baseline design of the facility being developed by the International Design Study for the Neutrino Factory (the IDS-NF) collaboration will be described.

  12. Steps towards the Neutrino Factory

    International Nuclear Information System (INIS)

    Long, K.

    2012-01-01

    The properties of the neutrino provide a unique window on physics beyond that described by the Standard Model. The study of sub-leading effects in neutrino oscillations has begun with the race to measure θ 13 . A consensus is emerging within the international community that a novel neutrino source is required to allow sensitive searches for leptonic CP violation to be carried out and the neutrino mass-hierarchy to be determined. The Neutrino Factory, in which intense neutrino beams are produced from the decay of muons, has been shown to out-perform the other proposed facilities. The physics case for the Neutrino Factory will be reviewed and the baseline design of the facility being developed by the International Design Study for the Neutrino Factory (the IDS-NF) collaboration will be described.

  13. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  14. Cell Factory Engineering

    DEFF Research Database (Denmark)

    Davy, Anne Mathilde; Kildegaard, Helene Faustrup; Andersen, Mikael Rørdam

    2017-01-01

    focused on individual strategies or cell types, but collectively they fall under the broad umbrella of a growing field known as cell factory engineering. Here we condense >130 reviews and key studies in the art into a meta-review of cell factory engineering. We identified 33 generic strategies......-review provides general strategy guides for the broad range of applications of rational engineering of cell factories....

  15. Spatial Cluster Detection for Repeatedly Measured Outcomes while Accounting for Residential History

    OpenAIRE

    Cook, Andrea J.; Gold, Diane R.; Li, Yi

    2009-01-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information ...

  16. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  17. Proper-time resolution function for measurement of time evolution of B mesons at the KEK B-Factory

    International Nuclear Information System (INIS)

    Tajima, H.; Aihara, H.; Higuchi, T.; Kawai, H.; Nakadaira, T.; Tanaka, J.; Tomura, T.; Yokoyama, M.; Hazumi, M.; Sakai, Y.; Sumisawa, K.; Kawasaki, T.

    2004-01-01

    The proper-time resolution function for the measurement of the time evolution of B mesons with the Belle detector at KEKB is studied in detail. The obtained resolution function is applied to the measurement of B meson lifetimes, the B0B-bar 0 oscillation frequency and time-dependent CP asymmetries

  18. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  19. PCs in the factory

    CERN Document Server

    2013-01-01

    Please note this is a short discount publication.PCs have become as essential to the factory environment as they are to the office environment. This in-depth report examines how specially adapted PCs and peripherals are being established in Factory Process Control and Reporting. The report covers: * Hardware and Software* Typical Applications* Implementation Issues* Case Studies and Real Applications

  20. Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

    OpenAIRE

    Ruiz-Belda, Clara; Piñero, David P.; Ruiz Fortes, Pedro; Soto-Negro, Roberto; Moya, Myriam; Pérez Cambrodí, Rafael J.; Artola, Alberto

    2016-01-01

    Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the C...

  1. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  2. Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements.

    Science.gov (United States)

    Preis, Sarah Rosner; Spiegelman, Donna; Zhao, Barbara Bojuan; Moshfegh, Alanna; Baer, David J; Willett, Walter C

    2011-03-15

    Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (ρ) and deattenuation factor (λ), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure to account for within-person variation in biomarkers can exaggerate correlated errors between FFQs and 24-hour diet recalls. For 2 validation studies, ρ and λ were calculated for total energy and protein density. In the Automated Multiple-Pass Method Validation Study (n=471), doubly labeled water (DLW) and urinary nitrogen (UN) were measured twice in 52 adults approximately 16 months apart (2002-2003), yielding intraclass correlation coefficients of 0.43 for energy (DLW) and 0.54 for protein density (UN/DLW). The deattenuated correlation coefficient for protein density was 0.51 for correlation between the FFQ and the 24-hour diet recall and 0.49 for correlation between the FFQ and the biomarker. Use of repeat-biomarker measurement error models resulted in a ρ of 0.42. These models were similarly applied to the Observing Protein and Energy Nutrition Study (1999-2000). In conclusion, within-person variation in biomarkers can be substantial, and to adequately assess the impact of correlated subject-specific error, this variation should be assessed in validation studies of FFQs. © The Author 2011. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved.

  3. Assessment of the factorial validity and reliability of the ALSFRS-R: a revision of its measurement model.

    Science.gov (United States)

    Bakker, Leonhard A; Schröder, Carin D; van Es, Michael A; Westers, Paul; Visser-Meily, Johanna M A; van den Berg, Leonard H

    2017-07-01

    The amyotrophic lateral sclerosis functional rating scale-revised (ALSFRS-R) is a widely used primary outcome measure in amyotrophic lateral sclerosis (ALS) clinical practice and clinical trials. ALSFRS-R items cannot, however, validly be summed to obtain a total score, but constitute domain scores reflecting a profile of disease severity. Currently, there are different measurement models for estimating domain scores. The objective of the present study is, therefore, to derive the measurement model that best fits the data for a valid and uniform estimation of ALSFRS-R domain scores. Data from 1556 patients with ALS were obtained from a population-based register in The Netherlands. A random split of the sample provided a calibration and validation set. Measurement models of the ALSFRS-R were investigated using both exploratory factor analyses and confirmatory factor analyses. The measurement model with a four-factor structure (i.e., bulbar, fine motor, gross motor, and respiratory function), with correlated factors and cross-loading items on dressing and hygiene and turning in bed and adjusting bed clothes on both motor function scales, provided the best fit to the data in both sets. Correlation between factors ranged from weak to modest, confirming that the ALSFRS-R constitutes a profile of four clinically relevant domain scores rather than a total score that expresses disease severity. The internal consistency of the four domain scores was satisfactory. Our revision of the measurement model may allow for a more adequate estimation of disease severity and disease progression in epidemiological studies and clinical trials.

  4. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy.

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-07-01

    To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.

  5. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-01-01

    Purpose To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. Methods Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). Results For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Conclusions Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions. PMID:28738413

  6. Combined Time-Dependent CP Violation Measurements by the B factory experiments BaBar and Belle

    CERN Document Server

    CERN. Geneva

    2018-01-01

    During the 2000s, the BaBar experiment at SLAC in Stanford/USA and the Belle experiment at KEK in Tsukuba/Japan performed a very successful flavor physics program. In particular, BaBar and Belle discovered CP violation in the neutral and charged B meson system. In this talk, we present the results of two measurements from a novel analysis campaign by the former 'friendly competitors'. The novel approach combines the integrated luminosity of about 1.1 inverse attobarn collected by both experiments in single physics analyses. The first combined measurement presented is a time-dependent CP violation measurement of $B^{0} \\to D^{(*)}_{CP} h^{0}$ decays, where the light neutral hadron $h^{0}$ is a $\\pi^{0}$, $\\eta$ or $\\omega$ meson, and the neutral $D$ meson is reconstructed in decays to the two-body CP eigenstates $K^{+}K^{-}$, $K_{S}^{0}\\pi^{0}$ or $K_{S}^{0}\\omega$. A first observation of CP violation governed by mixing-induced CP violation according to $\\sin{2\\beta}$ is reported. The second combined measurem...

  7. EFFICIENCY OF REPEATED AND UNSCHEDULED TRAINING AS THE MEASURES TO PREVENT ACCIDENTS AT SUPPLY DEPOTS AND WAREHOUSES

    Directory of Open Access Journals (Sweden)

    Bocharova Irina Nikolaevna

    2013-05-01

    Full Text Available This paper presents the results of the analysis of the state of occupational safety at supply depots and warehouses. It is revealed that most accidents involve the employees who have less than one year’s service. Experience has proven that the preventive activities to avoid occupational traumatism are efficient when a complex of workplace safety measures is implemented. The experts consider the repeated and unscheduled training to be very important events. This is supported by the fact that among the employees of the commercial establishments who underwent repeated and unscheduled training, the number of individuals who suffered an accident is small. The efficient functioning of the occupational safety training system is infeasible without ensuring the motivation for assimilating the knowledge and forming the complete foundation for safe labor. In order to reduce the number of accidents, one should proceed from the principle of responding to accidents to the system for professional risk management.

  8. Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

    Science.gov (United States)

    Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C

    2015-07-01

    The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p rc = 0.9981 vs. 0.9953; p plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.

  9. Towards energy transparent factories

    CERN Document Server

    Posselt, Gerrit

    2016-01-01

    This monograph provides a methodological approach for establishing demand-oriented levels of energy transparency of factories. The author presents a systematic indication of energy drivers and cost factors, taking into account the interdependencies between facility and production domains. Particular attention is given to energy flow metering and monitoring. Readers will also be provided with an in-depth description of a planning tool which allows for systematically deriving suitable metering points in complex factory environments. The target audience primarily comprises researchers and experts in the field of factory planning, but the book may also be beneficial for graduate students.

  10. Characteristics and reference ranges of Insulin-Like Growth Factor-I measured with a commercially available immunoassay in 724 healthy adult Caucasians

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Nielsen, Kaspar; Raymond, Ilan

    2009-01-01

    BACKGROUND AND OBJECTIVE: Measurements of Insulin-Like Growth Factor-I (IGF-I) play a pivotal role in the evaluation of the growth hormone-IGF-I axis. Due to assay variation IGF-I reference ranges are assay specific. We provide serum IGF-I reference ranges for adult men and women obtained...... by a commercially available assay. METHOD: IGF-I was measured by an enzyme-linked immunosorbent assay (R&D Systems). Assay precision was evaluated in low, medium and high IGF-I pools and in single samples from outpatients. The reference ranges were obtained in 724 healthy Caucasians, mean age 48 years (range 19....../mL (mean 1 SD) were 5, 3 and 3%. Interassays CVs for the low, medium and high pool varied between 7-10, 5-7, and 6-9%. Reproducibility between 4 different lots showed a intraclass CV of 0.99 (95%CI 0.98-0.96). Logarithmically transformed IGF-I levels were linearly associated with age with a 13% reduction...

  11. Intergenic and repeat transcription in human, chimpanzee and macaque brains measured by RNA-Seq.

    Directory of Open Access Journals (Sweden)

    Augix Guohua Xu

    Full Text Available Transcription is the first step connecting genetic information with an organism's phenotype. While expression of annotated genes in the human brain has been characterized extensively, our knowledge about the scope and the conservation of transcripts located outside of the known genes' boundaries is limited. Here, we use high-throughput transcriptome sequencing (RNA-Seq to characterize the total non-ribosomal transcriptome of human, chimpanzee, and rhesus macaque brain. In all species, only 20-28% of non-ribosomal transcripts correspond to annotated exons and 20-23% to introns. By contrast, transcripts originating within intronic and intergenic repetitive sequences constitute 40-48% of the total brain transcriptome. Notably, some repeat families show elevated transcription. In non-repetitive intergenic regions, we identify and characterize 1,093 distinct regions highly expressed in the human brain. These regions are conserved at the RNA expression level across primates studied and at the DNA sequence level across mammals. A large proportion of these transcripts (20% represents 3'UTR extensions of known genes and may play roles in alternative microRNA-directed regulation. Finally, we show that while transcriptome divergence between species increases with evolutionary time, intergenic transcripts show more expression differences among species and exons show less. Our results show that many yet uncharacterized evolutionary conserved transcripts exist in the human brain. Some of these transcripts may play roles in transcriptional regulation and contribute to evolution of human-specific phenotypic traits.

  12. The Repeated Administration of Resveratrol Has Measurable Effects on Circulating T-Cell Subsets in Humans

    Directory of Open Access Journals (Sweden)

    J. Luis Espinoza

    2017-01-01

    Full Text Available Preclinical studies have shown that resveratrol exerts immunomodulatory effects with potential clinical value in the amelioration of autoimmune disorders and cancer prevention; however, little is known about the in vivo effects of this naturally occurring polyphenol on human immune cells. We assessed the effects of repeated doses of resveratrol (1000 mg/day for 28 days on circulating immune cells in healthy Japanese individuals. Resveratrol was safe and well tolerated and was associated with significant increases in the numbers of circulating γδ T cells and regulatory T cells and resulted in small, yet significant, decreases in the plasma levels of the proinflammatory cytokines TNF-α and MCP-1 and a significant increase in the plasma antioxidant activity compared with the corresponding antioxidant baseline activity and with that in four control individuals. In in vitro studies, resveratrol significantly improved the growth of γδ T cells and regulatory T cells. These findings demonstrate that resveratrol has some clear biological effects on human circulating immune cells. Further studies are necessary to interpret the long-term immunological changes associated with resveratrol treatment.

  13. Can we measure working memory via the Internet? The reliability and factorial validity of an online n-back task

    Directory of Open Access Journals (Sweden)

    Kulikowski Konrad

    2016-04-01

    Full Text Available The aim of this study was to check whether an online n-back task conducted in the uncontrolled environment of the Internet can yield valid and reliable data. For this purpose, 169 participants completed an online n-back task with n1, n2 and n3 blocks on their home computers. The results have shown acceptable reliability for overall accuracy and reaction time indices across n1, n2, n3 blocks, as well as for reaction time indices for each n block. Unacceptable reliability has been found for separate n levels accuracy indices and for response bias indices. Confirmatory factor analysis has revealed that, among 8 proposed measurement models, the best fit for the data collected is a model with two uncorrelated factors: accuracy consisting of n1, n2, n3 indices and reaction time consisting of n2, n3 indices. The results of this study have demonstrated for the first time that a reliable administration of online n-back task is possible and may therefore give rise to new opportunities for working memory research.

  14. Planned Positron Factory project

    International Nuclear Information System (INIS)

    Okada, Sohei

    1990-01-01

    The Japan Atomic Energy Research Institute, JAERI, has started, drafting a construction plan for the 'Positron Factory', in which intense energy-controllable monoenergetic positron beams are produced from pair-production reactions caused by high-energy electrons from a linac. The JAERI organized a planning committee to provide a basic picture for the Positron Factory. This article presents an overview of the interactions of positrons, intense positron sources and the research program and facilities planned for the project. The interactions of positrons and intense positron sources are discussed focusing on major characteristics of positrons in different energy ranges. The research program for the Positron Factory is then outlined, focusing on advanced positron annihilation techniques, positron spectroscopy (diffraction, scattering, channeling, microscopy), basic positron physics (exotic particle science), and positron beam technology. Discussion is also made of facilities required for the Positron Factory. (N.K.)

  15. Virtual Factory Testbed

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Factory Testbed (VFT) is comprised of three physical facilities linked by a standalone network (VFNet). The three facilities are the Smart and Wireless...

  16. TRIUMF kaon factory plans

    International Nuclear Information System (INIS)

    Blackmore, E.W.

    1983-01-01

    A progress report on the TRIUMF Kaon Factory Feasibility Study is presented. The requirements placed on the machine parameters and experimental facilities by the potentially interesting experiments are discussed

  17. TRIUMF kaon factory plans

    International Nuclear Information System (INIS)

    Blackmore, E.W.

    1982-11-01

    A progress report on the TRIUMF Kaon Factory Feasibility Study is presented. The requirements placed on the machine parameters and experimental facilities by the potentially interesting experiments are discussed

  18. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  19. Repeatable aversion across threat types is linked with life-history traits but is dependent on how aversion is measured.

    Science.gov (United States)

    Davidson, Gabrielle L; Reichert, Michael S; Crane, Jodie M S; O'Shea, William; Quinn, John L

    2018-02-01

    Personality research suggests that individual differences in risk aversion may be explained by links with life-history variation. However, few empirical studies examine whether repeatable differences in risk avoidance behaviour covary with life-history traits among individuals in natural populations, or how these links vary depending on the context and the way risk aversion is measured. We measured two different risk avoidance behaviours (latency to enter the nest and inspection time) in wild great tits ( Parus major ) in two different contexts-response to a novel object and to a predator cue placed at the nest-box during incubation---and related these behaviours to female reproductive success and condition. Females responded equally strongly to both stimuli, and although both behaviours were repeatable, they did not correlate. Latency to enter was negatively related to body condition and the number of offspring fledged. By contrast, inspection time was directly explained by whether incubating females had been flushed from the nest before the trial began. Thus, our inferences on the relationship between risk aversion and fitness depend on how risk aversion was measured. Our results highlight the limitations of drawing conclusions about the relevance of single measures of a personality trait such as risk aversion.

  20. Short-term Changes of Apparent Optical Properties in a Shallow Water Environment: Observations from Repeated Airborne Hyperspectral Measurements

    Science.gov (United States)

    Zhang, M.; English, D. C.; Hu, C.; Carlson, P. R., Jr.; Muller-Karger, F. E.; Toro-Farmer, G.; Herwitz, S. R.

    2016-02-01

    An atmospheric correction algorithm has been developed for AISA imagery over optically shallow waters in Sugarloaf Key of the Florida Keys. The AISA data were collected repeatedly during several days in May 2012, October 2012, and May 2013. A non-zero near-infrared (NIR) remote sensing reflectance (Rrs) was accounted for through iterations, based on the relationship of field-measured Rrs between the NIR and red wavelengths. Validation showed mean ratios of 0.94 to 1.002 between AISA-derived and field-measured Rrs in the blue to red wavelengths, with uncertainties generally turbidity (light attenuation) and bottom contributions. Some of these changes are larger than two times of the Rrs uncertainties from the AISA retrievals, therefore representing statistically significant changes that can be well observed from airborne measurements. The case study suggests that repeated airborne measurements may be used to study short-term changes in shallow water environments, and such a capacity may be enhanced with future geostationary satellite missions specifically designed to observe coastal ecosystems.

  1. Super B Factories

    Indian Academy of Sciences (India)

    B factory; CP violation; B meson; supersymmetry. PACS Nos 11.30.Hv; 11.30.Pb; 12.15.Hh; 12.15.Mm; 13.20.He; 13.20.Fc;. 13.35.Dx; 14.65.Fy. 1. Introduction. The two asymmetric B factories, PEP-II and KEK-B, and their companion detec- tors, BABAR and Belle, have produced a wealth of flavor physics results, subjecting.

  2. Measuring the Dynamic Soil Response During Repeated Wheeling Using Seismic Methods

    DEFF Research Database (Denmark)

    Keller, Thomas; Carizzon, Marco; Berisso, Feto Esimo

    2013-01-01

    was performed with an agricultural tire (60 kN wheel load) on a gleyic Cambisol. We measured Vp using an acoustic (microseismic) device at various depths before, during (i.e., below the tire), and after wheeling. In addition, we measured bulk density and penetrometer resistance before and after wheeling...

  3. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  4. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  5. Factorial correlators: angular scaling within QCD jets

    International Nuclear Information System (INIS)

    Peschanski, R.

    2001-01-01

    Factorial correlators measure the amount of dynamical correlation in the multiplicity between two separated phase-space windows. We present the analytical derivation of factorial correlators for a QCD jet described at the double logarithmic (DL) accuracy. We obtain a new angular scaling property for properly normalized correlators between two solid-angle cells or two rings around the jet axis. Normalized QCD factorial correlators scale with the angular distance and are independent of the window size. Scaling violations are expected beyond the DL approximation, in particular from the subject structure. Experimental tests are feasible, and thus would be welcome. (orig.)

  6. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  7. The nearby supernova factory

    International Nuclear Information System (INIS)

    Wood-Vasey, W.M.; Aldering, G.; Lee, B.C.; Loken, S.; Nugent, P.; Perlmutter, S.; Siegrist, J.; Wang, L.; Antilogus, P.; Astier, P.; Hardin, D.; Pain, R.; Copin, Y.; Smadja, G.; Gangler, E.; Castera, A.; Adam, G.; Bacon, R.; Lemonnier, J.-P.; Pecontal, A.; Pecontal, E.; Kessler, R.

    2004-01-01

    The Nearby Supernova Factory (SNfactory) is an ambitious project to find and study in detail approximately 300 nearby Type Ia supernovae (SNe Ia) at redshifts 0.03 < z < 0.08. This program will provide an exceptional data set of well-studied SNe in the nearby smooth Hubble flow that can be used as calibration for the current and future programs designed to use SNe to measure the cosmological parameters. The first key ingredient for this program is a reliable supply of Hubble-flow SNe systematically discovered in unprecedented numbers using the same techniques as those used in distant SNe searches. In 2002, 35 SNe were found using our test-bed pipeline for automated SN search and discovery. The pipeline uses images from the asteroid search conducted by the Near Earth Asteroid Tracking group at JPL. Improvements in our subtraction techniques and analysis have allowed us to increase our effective SN discovery rate to ∼12 SNe/month in 2003

  8. Attrition from Web-Based Cognitive Testing: A Repeated Measures Comparison of Gamification Techniques.

    Science.gov (United States)

    Lumsden, Jim; Skinner, Andy; Coyle, David; Lawrence, Natalia; Munafo, Marcus

    2017-11-22

    The prospect of assessing cognition longitudinally and remotely is attractive to researchers, health practitioners, and pharmaceutical companies alike. However, such repeated testing regimes place a considerable burden on participants, and with cognitive tasks typically being regarded as effortful and unengaging, these studies may experience high levels of participant attrition. One potential solution is to gamify these tasks to make them more engaging: increasing participant willingness to take part and reducing attrition. However, such an approach must balance task validity with the introduction of entertaining gamelike elements. This study aims to investigate the effects of gamelike features on participant attrition using a between-subjects, longitudinal Web-based testing study. We used three variants of a common cognitive task, the Stop Signal Task (SST), with a single gamelike feature in each: one variant where points were rewarded for performing optimally; another where the task was given a graphical theme; and a third variant, which was a standard SST and served as a control condition. Participants completed four compulsory test sessions over 4 consecutive days before entering a 6-day voluntary testing period where they faced a daily decision to either drop out or continue taking part. Participants were paid for each session they completed. A total of 482 participants signed up to take part in the study, with 265 completing the requisite four consecutive test sessions. No evidence of an effect of gamification on attrition was observed. A log-rank test showed no evidence of a difference in dropout rates between task variants (χ 2 2 =3.0, P=.22), and a one-way analysis of variance of the mean number of sessions completed per participant in each variant also showed no evidence of a difference (F 2,262 =1.534, P=.21, partial η 2 =0.012). Our findings raise doubts about the ability of gamification to reduce attrition from longitudinal cognitive testing studies

  9. Direct and Repeated Clinical Measurements of pO2 for Enhancing Cancer Therapy and Other Applications.

    Science.gov (United States)

    Swartz, Harold M; Williams, Benjamin B; Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A; Chen, Eunice Y; Schaner, Philip E; Ali, Arif; Gallez, Bernard; Kuppusamy, Periannan; Flood, Ann B

    2016-01-01

    The first systematic multi-center study of the clinical use of EPR oximetry has begun, with funding as a PPG from the NCI. Using particulate oxygen sensitive EPR, materials in three complementary forms (India Ink, "OxyChips", and implantable resonators) the clinical value of the technique will be evaluated. The aims include using repeated measurement of tumor pO2 to monitor the effects of treatments on tumor pO2, to use the measurements to select suitable subjects for the type of treatment including the use of hyperoxic techniques, and to provide data that will enable existing clinical techniques which provide data relevant to tumor pO2 but which cannot directly measure it to be enhanced by determining circumstances where they can give dependable information about tumor pO2.

  10. Looking back on a half century of repeat magnetic measurements in France

    Science.gov (United States)

    Alexandrescu, Mioara Mandea; Gilder, Stuart; Courtillot, Vincent; Le Mouël, Jean Louis; Gilbert, Daniel

    Birds do it. Bees do it. And with the discovery of lodestone over 2200 years ago, humans too could incorporate the Earth's magnetic field into their daily lives. Some of the oldest applications for tracking the magnetic field were in land and sea navigation. Magnetic field measurements quickly became an important economic factor in world trade, with documented use dating from the 11th century in China.The measurements are important in other applications as well. For example, rapid field variations are generated by solar activity and its interaction with the terrestrial environment. Large magnetic storms can disrupt satellite operation, communication systems, power transmission networks, and so forth [Campbell, 1997].Geomagnetism also provides a unique opportunity to explore the Earth's outer core, which is mostly liquid (molten) iron, where the field is generated. Field measurements can also yield valuable insights into the location of mineral deposits and aid in applications in the petroleum industry.

  11. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  12. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    Science.gov (United States)

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  13. Tau-charm factory..

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-10-15

    In addition to hearing the latest experimental and theoretical developments at the 17th International Symposium on Lepton Photon Interactions in Beijing, delegates were brought up-to-date on the substantial progress towards the realization of a Tau-Charm Factory in the Chinese capital. Opening the Symposium, Zhou Guangzhao, President of the Chinese Academy of Sciences, expressed a commitment of the Chinese government to basic research and its interest in the continuing development high energy physics in China. Following the very successful construction and operation of Beijing's Electron-Positron Collider, BEPC, the Chinese government has provided 5M yuan ($US 600,000) for a feasibility study by the end of 1996 for a Tau-Charm Factory at Beijing's Institute of High Energy Physics (IHEP). Professor Zhou expressed his belief that, once approved, such a factory would greatly enhance high energy physics in China. He warmly welcomed international collaboration both in the construction of the accelerator and in the experimental programme. His comments were reinforced in the following welcome speech by IHEP Director Zheng Zhipeng. Conference delegates had the opportunity to inspect the BEPC injector and collider, built almost entirely by Chinese industry. The International Committee for Future Accelerators (ICFA) met during the Symposium, with Tau- Charm Factory business on the agenda. In his subsequent report, ICFA Chairman John Peoples said that a Tau-Charm Factory provides a unique experimental environment for the precision studies of tau, charm and light quark-gluon spectroscopy, and that some issues in these fields are not satisfactorily addressed solely by B Factories or fixed-target experiments. The committee expressed a strong interest in seeing a Tau-Charm Factory built and noted the serious interest, especially in China, and looks forward to operation and exploitation by the international physics community. In their Beijing summary talks, both Sam Ting and T

  14. Tau-charm factory..

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    In addition to hearing the latest experimental and theoretical developments at the 17th International Symposium on Lepton Photon Interactions in Beijing, delegates were brought up-to-date on the substantial progress towards the realization of a Tau-Charm Factory in the Chinese capital. Opening the Symposium, Zhou Guangzhao, President of the Chinese Academy of Sciences, expressed a commitment of the Chinese government to basic research and its interest in the continuing development high energy physics in China. Following the very successful construction and operation of Beijing's Electron-Positron Collider, BEPC, the Chinese government has provided 5M yuan ($US 600,000) for a feasibility study by the end of 1996 for a Tau-Charm Factory at Beijing's Institute of High Energy Physics (IHEP). Professor Zhou expressed his belief that, once approved, such a factory would greatly enhance high energy physics in China. He warmly welcomed international collaboration both in the construction of the accelerator and in the experimental programme. His comments were reinforced in the following welcome speech by IHEP Director Zheng Zhipeng. Conference delegates had the opportunity to inspect the BEPC injector and collider, built almost entirely by Chinese industry. The International Committee for Future Accelerators (ICFA) met during the Symposium, with Tau- Charm Factory business on the agenda. In his subsequent report, ICFA Chairman John Peoples said that a Tau-Charm Factory provides a unique experimental environment for the precision studies of tau, charm and light quark-gluon spectroscopy, and that some issues in these fields are not satisfactorily addressed solely by B Factories or fixed-target experiments. The committee expressed a strong interest in seeing a Tau-Charm Factory built and noted the serious interest, especially in China, and looks forward to operation and exploitation by the international physics community. In their Beijing summary talks, both Sam Ting

  15. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  16. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  17. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  18. Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.

    Science.gov (United States)

    Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T

    2001-08-01

    To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA

  19. Health Services OutPatient Experience questionnaire: factorial validity and reliability of a patient-centered outcome measure for outpatient settings in Italy

    Directory of Open Access Journals (Sweden)

    Coluccia A

    2014-09-01

    Full Text Available Anna Coluccia, Fabio Ferretti, Andrea PozzaDepartment of Medical Sciences, Surgery and Neurosciences, Santa Maria alle Scotte University Hospital, University of Siena, Siena, ItalyPurpose: The patient-centered approach to health care does not seem to be sufficiently developed in the Italian context, and is still characterized by the biomedical model. In addition, there is a lack of validated outcome measures to assess outpatient experience as an aspect common to a variety of settings. The current study aimed to evaluate the factorial validity, reliability, and invariance across sex of the Health Services OutPatient Experience (HSOPE questionnaire, a short ten-item measure of patient-centeredness for Italian adult outpatients. The rationale for unidimensionality of the measure was that it could cover global patient experience as a process common to patients with a variety of diseases and irrespective of the phase of treatment course.Patients and methods: The HSOPE was compiled by 1,532 adult outpatients (51% females, mean age 59.22 years, standard deviation 16.26 receiving care in ten facilities at the Santa Maria alle Scotte University Hospital of Siena, Italy. The sample represented all the age cohorts. Twelve percent were young adults, 57% were adults, and 32% were older adults. Exploratory and confirmatory factor analyses were conducted to evaluate factor structure. Reliability was evaluated as internal consistency using Cronbach’s α. Factor invariance was assessed through multigroup analyses.Results: Both exploratory and confirmatory analyses suggested a clearly defined unidimensional structure of the measure, with all the ten items having salient loadings on a single factor. Internal consistency was excellent (α=0.95. Indices of model fit supported a single-factor structure for both male and female outpatient groups. Young adult outpatients had significantly lower scores on perceived patient-centeredness relative to older adults. No

  20. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. The effects of toluene plus noise on hearing thresholds: an evaluation based on repeated measurements in the German printing industry.

    Science.gov (United States)

    Schäper, Michael; Seeber, Andreas; van Thriel, Christoph

    2008-01-01

    The ototoxicity of occupational exposure to toluene plus noise was investigated in a longitudinal study in rotogravure printing and existing findings in the literature were evaluated. The study comprised four repeated examinations during 5 years and started with 333 male workers. Lifetime weighted average exposures (LWAE) to toluene and noise were determined from individual work histories and historic recordings; recent individual exposures were measured 10 times during the study (toluene, active sampling; noise, stationary measurements). Auditory thresholds were measured with pure tone audiometry at 0.125, 0.25, 0.5, 0.75, 1, 2, 3, 4, 6, 8, 12 kHz. Mean LWAE exposures to toluene and noise were 45+/-17 ppm plus 82+/-7 dB(A) for high toluene exposed and 10+/-7 ppm plus 82+/-4 dB(A) for low toluene exposed subjects, mean current exposures were 26+/-20 ppm plus 81+/-4 dB(A) and 3+/-3 ppm plus 82+/-4 dB(A). Mean exposure duration was 21.3+/-6.5 years for long exposed and 5.9+/-2.2 years for short exposed subjects. Repeated measurement analyses of variance did not reveal effects of toluene intensity, exposure duration and interactions between toluene intensity and noise intensity. Noise intensity [79+/-3 dB(A) vs. 84+/-1 dB(A)] was significant for auditory thresholds. A case concept utilising developments of individual auditory thresholds did not reveal significant toluene effects. Logistic models including age, exposure duration, toluene in ambient air, current noise and either hippuric acid or ortho-cresol (o-cresol) found only age to be significant for elevated OR of high frequency hearing loss. Due to missing toluene effects, it was concluded that the threshold level for developing hearing loss as a result of occupational exposure to toluene plus noise might be above the current limit of 50 ppm toluene.

  2. Colorful Microbial Cell Factories

    DEFF Research Database (Denmark)

    Petersen, Pia Damm

    Yeast cell factories are powerful tools used for the production of high-value natural compounds otherwise not easily available. Many bioactive and industrially important plant secondary metabolites can be produced in yeast by engineering their biosynthetic pathways into yeast cells, as these both...... anthocyanins. Yeast cell factories present a platform to circumvent the problem of low yields of interesting molecular structures in plant tissues, as hand-picking of desired enzyme activities allows for specific biosynthesis of the precise pigment of interest, as well as choosing more stable structures...... for heterologous biosynthesis is possible. In cell factories, great improvements in yields can be achieved through molecular engineering of flux from endogenous yeast precursors, e.g. by elimination of by-product formation, and by genetic optimization of pathway components, such as fine-tuning of expression levels...

  3. The Smart Factory

    DEFF Research Database (Denmark)

    Radziwon, Agnieszka; Bilberg, Arne; Bogers, Marcel

    2014-01-01

    Nowadays we live in a world, which a decade ago would only be described in the science fiction literature. More and more things become smart and both scientists and engineers strive for developing not only new and innovative devices, but also homes, factories, or even cities. Despite of continuous...... development, many of those concepts are still being just a vision of the future, which still needs a lot of effort to become true. This paper reviews the usage of adjective smart in respect to technology and with a special emphasis on the smart factory concept placement among contemporary studies. Due...... to a lack of a consensus of common understanding of this term, a unified definition is proposed. The conceptualization will not only refer to various smart factory visions reported in the literature, but also link the crucial characteristics of this emerging manufacturing concept to usual manufacturing...

  4. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  5. Photon Factory activity report, 1990

    International Nuclear Information System (INIS)

    1991-01-01

    The Photon Factory has grown at a considerable rate, and 600 experiments are carried out in 1991, while the number of users is now 2300 including about 500 from industrial sectors. The use of synchrotron radiation increased from fundamental research to industrial development. The development at the Photon Factory is supported by the capability of the accelerators. At present, the 2.5 GeV PF ring is operated with positrons at the initial beam current of 350 mA. The total operation time was 3500 hours in the fiscal year 1990. The development of an avalanche mode photodiode, the observation of quantum beat in the experiment of nuclear Bragg scattering, the measurement of photo-electron and photo-ion spectroscopy were carried out. The conversion of TRISTAN main ring to an ultrahigh brilliance and high coherence source is planned for the future. The annual PF Symposium was held, and Professor H. Winick gave the lecture 'Ultrahigh brightness and coherent radiation from large storage rings'. In this report, the outline of the Photon Factory and the activities in Divisions of Injector Linac, Light Source and Instrumentation are described. (K.I.)

  6. Repeated measurement of nasal lavage fluid chemokines in school-age children with asthma.

    Science.gov (United States)

    Noah, Terry L; Tudor, Gail E; Ivins, Sally S; Murphy, Paula C; Peden, David B; Henderson, Frederick W

    2006-02-01

    Inflammatory processes at the mucosal surface may play a role in maintenance of asthma pathophysiology. Cross-sectional studies in asthmatic patients suggest that chemokines such as interleukin 8 (IL-8) are overproduced by respiratory epithelium. To test the hypothesis that chemokine levels are persistently elevated in the respiratory secretions of asthmatic children at a stable baseline. We measured nasal lavage fluid (NLF) levels of chemokines and other mediators at 3- to 4-month intervals in a longitudinal study of asthmatic children, with nonasthmatic siblings as controls. In a linear mixed-model analysis, both family and day of visit had significant effects on nasal mediators. Thus, data for 12 asthmatic-nonasthmatic sibling pairs who had 3 or more same-day visits were analyzed separately. For sibling pairs, median eosinophil cationic protein levels derived from serial measurements in NLF were elevated in asthmatic patients compared with nonasthmatic patients, with a near-significant tendency for elevation of total protein and eotaxin levels as well. However, no significant differences were found for IL-8 or several other chemokines. Ratios of IL-13 or IL-5 to interferon-gamma released by house dust mite antigen-stimulated peripheral blood mononuclear cells, tested on a single occasion, were significantly increased for asthmatic patients. Substantial temporal and family-related variability exists in nasal inflammation in asthmatic children. Although higher levels of eosinophil cationic protein are usually present in NLF of patients with stable asthma compared with patients without asthma, chemokines other than eotaxin are not consistently increased. Eosinophil activation at the mucosal surface is a more consistent predictor of asthmatic symptoms than nonspecific elevation of epithelium-derived inflammatory chemokine levels.

  7. Construction and updating of a public events questionnaire for repeated measures longitudinal studies

    Directory of Open Access Journals (Sweden)

    Martha eNoone

    2014-03-01

    Full Text Available Impairments of retrospective memory and cases of retrograde amnesia are often seen in clinical settings. A measure of the proportion of memories retained over a specified time can be useful in clinical situations and public events questionnaires may be valuable in this respect. However, consistency of retention of public events memory has rarely been studied in the same participants. In addition, when used in a research context, public events questionnaires require updating to ensure questions are of equivalent age with respect to when the test is taken. This paper describes an approach to constructing and updating a Public Events Questionnaire (PEQ for use with a sample that is recruited and followed-up over a long time-period. Internal consistency, parallel-form reliability, test-retest reliability and secondary validity analyses were examined for three versions of the PEQ that were updated every six months. Versions 2 and 3 of the questionnaire were reliable across and within versions and for recall and recognition. Change over time was comparable across each version of the PEQ. These results show that PEQs can be regularly updated in a standardised fashion to allow use throughout studies with long recruitment periods.

  8. Magnetic Resonance Spectroscopy in Patients with Insomnia: A Repeated Measurement Study.

    Directory of Open Access Journals (Sweden)

    Kai Spiegelhalder

    Full Text Available Chronic insomnia is one of the most prevalent central nervous system disorders. It is characterized by increased arousal levels, however, the neurobiological causes and correlates of hyperarousal in insomnia remain to be further determined. In the current study, magnetic resonance spectroscopy was used in the morning and evening in a well-characterized sample of 20 primary insomnia patients (12 females; 8 males; 42.7 ± 13.4 years and 20 healthy good sleepers (12 females; 8 males; 44.1 ± 10.6 years. The most important inhibitory and excitatory neurotransmitters of the central nervous system, γ-aminobutyric acid (GABA and glutamate/glutamine (Glx, were assessed in the anterior cingulate cortex (ACC and dorsolateral prefrontal cortex (DLPFC. The primary hypothesis, a diurnal effect on GABA levels in patients with insomnia, could not be confirmed. Moreover, the current results did not support previous findings of altered GABA levels in individuals with insomnia. Exploratory analyses, however, suggested that GABA levels in the ACC may be positively associated with habitual sleep duration, and, thus, reduced GABA levels may be a trait marker of objective sleep disturbances. Moreover, there was a significant GROUP x MEASUREMENT TIME interaction effect on Glx in the DLPFC with increasing Glx levels across the day in the patients but not in the control group. Therefore, Glx levels may reflect hyperarousal at bedtime in those with insomnia. Future confirmatory studies should include larger sample sizes to investigate brain metabolites in different subgroups of insomnia.

  9. Construction and updating of a public events questionnaire for repeated measures longitudinal studies.

    Science.gov (United States)

    Noone, Martha; Semkovska, Maria; Carton, Mary; Dunne, Ross; Horgan, John-Paul; O'Kane, Breige; McLoughlin, Declan M

    2014-01-01

    Impairments of retrospective memory and cases of retrograde amnesia are often seen in clinical settings. A measure of the proportion of memories retained over a specified time can be useful in clinical situations and public events questionnaires may be valuable in this respect. However, consistency of retention of public events memory has rarely been studied in the same participants. In addition, when used in a research context, public events questionnaires require updating to ensure questions are of equivalent age with respect to when the test is taken. This paper describes an approach to constructing and updating a Public Events Questionnaire (PEQ) for use with a sample that is recruited and followed-up over a long time-period. Internal consistency, parallel-form reliability, test-retest reliability, and secondary validity analyses were examined for three versions of the PEQ that were updated every 6 months. Versions 2 and 3 of the questionnaire were reliable across and within versions and for recall and recognition. Change over time was comparable across each version of the PEQ. These results show that PEQs can be regularly updated in a standardized fashion to allow use throughout studies with long recruitment periods.

  10. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients...... with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...... macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm...

  11. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  12. A comparison of parallel dust and fibre measurements of airborne chrysotile asbestos in a large mine and processing factories in the Russian Federation

    NARCIS (Netherlands)

    Feletto, Eleonora; Schonfeld, Sara J; Kovalevskiy, Evgeny V; Bukhtiyarov, Igor V; Kashanskiy, Sergey V; Moissonnier, Monika; Straif, Kurt; Kromhout, Hans

    2017-01-01

    INTRODUCTION: Historic dust concentrations are available in a large-scale cohort study of workers in a chrysotile mine and processing factories in Asbest, Russian Federation. Parallel dust (gravimetric) and fibre (phase-contrast optical microscopy) concentrations collected in 1995, 2007 and 2013/14

  13. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  14. Performance of bias-correction methods for exposure measurement error using repeated measurements with and without missing data.

    Science.gov (United States)

    Batistatou, Evridiki; McNamee, Roseanne

    2012-12-10

    It is known that measurement error leads to bias in assessing exposure effects, which can however, be corrected if independent replicates are available. For expensive replicates, two-stage (2S) studies that produce data 'missing by design', may be preferred over a single-stage (1S) study, because in the second stage, measurement of replicates is restricted to a sample of first-stage subjects. Motivated by an occupational study on the acute effect of carbon black exposure on respiratory morbidity, we compare the performance of several bias-correction methods for both designs in a simulation study: an instrumental variable method (EVROS IV) based on grouping strategies, which had been recommended especially when measurement error is large, the regression calibration and the simulation extrapolation methods. For the 2S design, either the problem of 'missing' data was ignored or the 'missing' data were imputed using multiple imputations. Both in 1S and 2S designs, in the case of small or moderate measurement error, regression calibration was shown to be the preferred approach in terms of root mean square error. For 2S designs, regression calibration as implemented by Stata software is not recommended in contrast to our implementation of this method; the 'problematic' implementation of regression calibration although substantially improved with use of multiple imputations. The EVROS IV method, under a good/fairly good grouping, outperforms the regression calibration approach in both design scenarios when exposure mismeasurement is severe. Both in 1S and 2S designs with moderate or large measurement error, simulation extrapolation severely failed to correct for bias. Copyright © 2012 John Wiley & Sons, Ltd.

  15. B-factory detectors

    International Nuclear Information System (INIS)

    Marlow, D.R.

    2002-01-01

    The designs of the recently commissioned BaBar and Belle B-Factory detectors are described. The discussion is organized around the methods and instruments used to detect the so-called gold-plated-mode B 0 →J/ΨK S decays and related modes

  16. Factorial Analysis of Profitability

    OpenAIRE

    Georgeta VINTILA; Ilie GHEORGHE; Ioana Mihaela POCAN; Madalina Gabriela ANGHEL

    2012-01-01

    The DuPont analysis system is based on decomposing the profitability ratio in factors of influence. This paper describes the factorial analysis of profitability based on the DuPont system. Significant importance is given to the impact on various indicators on the shares value and profitability.

  17. The Clone Factory

    Science.gov (United States)

    Stoddard, Beryl

    2005-01-01

    Have humans been cloned? Is it possible? Immediate interest is sparked when students are asked these questions. In response to their curiosity, the clone factory activity was developed to help them understand the process of cloning. In this activity, students reenact the cloning process, in a very simplified simulation. After completing the…

  18. Four-legged factories

    International Nuclear Information System (INIS)

    Mackie, R.I.; Van der Walt, J.G.

    1982-01-01

    Insight into how ruminants utilise plant material, converting what is essentially waste into food, wool and draught power for Man is being sought by Animal Scientists using isotopic tracer techniques. Answers to cost-effectice biological conversion lie in the complex interactions of the rumen's microbial fermentation factory and the host animal's diet and metabolism

  19. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    Science.gov (United States)

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  20. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study.

    Science.gov (United States)

    Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S; Cohen, Allison; Coull, Brent A; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A; Li, Yongsheng; Stone, Peter H; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R

    2014-03-01

    Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Baseline BAD was negatively associated with particle pollution, including home/trip-integrated BC (-0.02 mm; 95% CI: -0.04, -0.003, for a 0.28 μg/m3 increase in BC), OC (-0.08 mm; 95% CI: -0.14, -0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Zanobetti A, Luttmann

  1. Haiti. Educating factory workers.

    Science.gov (United States)

    Hughes, H

    1990-04-01

    There are approximately 50,000 workers employed in the light assembly industry in Haiti. About 70% are women, the majority of whom are aged between 25 and 34 years, and are either single or in a nonpermanent relationship with the father of their children. Many live and work in appalling conditions, surviving on very low wages to support several children and an extended family. The acquired immunodeficiency syndrome (AIDS) is now a visible problem in many factories. In October 1988, the Center for the Promotion of Women Workers (Centre de Promotion des Femmes Ouvriers/CPFO) launched a pilot AIDS education program for factory women. The Center, based in a large industrial zone near the airport, runs a health clinic and courses in literacy, communications skills, health promotion and family planning. The new AIDS program allowed CPFO staff to gain entry into factories for the 1st time. Other courses were held outside working hours and outside factory premises. Staff contacted manages by telephone to arrange a meeting to discuss AIDS and to ask permission to hold educational "round tables" with workers. Of 18 managers in the factories approached over a 12-month period, only 2 refused entry to CPFO staff. Almost all managers reported they had registered between 2 and 5 deaths from AIDS among their employees over the past couple of years. A total of 85 educational sessions, each lasting about 2 hours, were held within 28 different factories, community or labor organizations reaching 3063 workers (male and female). In each session, the presentation was carried out by 2 CPFO trained monitors and included a slide show, flip charts, and the video "Met ko," originally produced for Haitian immigrants in New York. The most important aspect of the program was the training of 38 volunteer factory-based health promoters. These promoters attended the round table sessions, where they facilitated discussion and distributed condoms and were subsequently available for counseling co

  2. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    Science.gov (United States)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    Traditional methodologies for measuring ratios of stable isotopes within the xylem water of trees involve destructive coring of the stem. A recent approach involves permanently installed probes within the stem, and an on-site assembly of pumps, switching valves, gas lines, and climate-controlled structure for field deployment of a laser spectrometer. The former method limits the possible temporal resolution of sampling, and sample size, while the latter may not be feasible for many research groups. We present results from initial laboratory efforts towards developing a non-destructive, temporally-resolved technique for measuring stable isotope ratios within the xylem flow of trees. Researchers have used direct liquid-vapor equilibration as a method to measure isotope ratios of the water in soil pores. Typically, this is done by placing soil samples in a fixed container, and allowing the liquid water within the soil to come into isotopic equilibrium with the headspace of the container. Water can also be removed via cryogenic distillation or azeotropic distillation, with the resulting liquid tested for isotope ratios. Alternatively, the isotope ratios of the water vapor can be directly measured using a laser-based water vapor isotope analyzer. Well-established fractionation factors and the isotope ratios in the vapor phase are then used to calculate the isotope ratios in the liquid phase. We propose a setup which would install a single, removable chamber onto a tree, where vapor samples could non-destructively and repeatedly be taken. These vapor samples will be injected into a laser-based isotope analyzer by a recirculating gas conveyance system. A major part of what is presented here is in the procedure of taking vapor samples at 100% relative humidity, appropriately diluting them with completely dry N2 calibration gas, and injecting them into the gas conveyance system without inducing fractionation in the process. This methodology will be helpful in making

  3. Muon Colliders and Neutrino Factories

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, Daniel M. [IIT, Chicago

    2015-05-29

    Muon colliders and neutrino factories are attractive options for future facilities aimed at achieving the highest lepton-antilepton collision energies and precision measurements of Higgs boson and neutrino mixing matrix parameters. The facility performance and cost depend on how well a beam of muons can be cooled. Recent progress in muon cooling design studies and prototype tests nourishes the hope that such facilities could be built starting in the coming decade. The status of the key technologies and their various demonstration experiments is summarized. Prospects "post-P5" are also discussed.

  4. Magnets for TRIUMF's KAON factory

    International Nuclear Information System (INIS)

    Otter, A.J.; Reeve, P.A.

    1991-05-01

    The KAON Factory will require over 2000 magnets to transport protons from the existing 500 Mev cyclotron through three storage rings and two synchrotrons and deliver them to the experimental area at 30 Gev. The magnet requirements are summarized and the results of measurements on prototypes for the 50 hz Booster magnets are compared with design values. This paper will address three topics: the results of prototype work, some of the more difficult design aspects of other magnets and the tolerances required to achieve production magnets uniform to ± 2 parts in 10 4 . (Author) 10 refs., 3 figs., tab

  5. Design and Development of a Relative Humidity and Room Temperature Measurement System with On Line Data Logging Feature for Monitoring the Fermentation Room of Tea Factory

    Directory of Open Access Journals (Sweden)

    Utpal SARMA

    2011-12-01

    Full Text Available The design and development of a Relative Humidity (RH and Room Temperature (RT monitoring system with on line data logging feature for monitoring fermentation room of a tea factory is presented in this paper. A capacitive RH sensor with on chip signal conditioner is taken as RH sensor and a temperature to digital converter (TDC is used for ambient temperature monitoring. An 8051 core microcontroller is the heart of the whole system which reads the digital equivalent of RH data with the help of a 12-bit Analog to Digital (A/D converter and synchronize TDC to get the ambient temperature. The online data logging is achieved with the help of RS-232C communication. Field performance is also studied by installing it in the fermentation room of a tea factory.

  6. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Review of kaon factory proposals

    International Nuclear Information System (INIS)

    Thiessen, H.A.

    1985-01-01

    Nuclear physics issues and particle physics issues for a kaon factory are discussed. Kaon factory accelerator proposals are then considered. Secondary beam considerations are covered and hardware development for a kaon factory is discussed. The prospects for construction are presented. 9 refs., 12 figs., 2 tabs

  8. Superconducting cavities for beauty factories

    International Nuclear Information System (INIS)

    Lengeler, H.

    1992-01-01

    The possibilities and merits of superconducting accelerating cavities for Beauty-factories are considered. There exist already large sc systems of size and frequency comparable to the ones needed for Beauty-factories. Their status and operation experience is discussed. A comparison of normal conducting and superconducting systems is done for two typical Beauty-factory rings

  9. Hazardous factories: Nigerian evidence.

    Science.gov (United States)

    Oloyede, Olajide

    2005-06-01

    The past 15 years have seen an increasing governmental and corporate concern for the environment worldwide. For governments, information about the environmental performance of the industrial sector is required to inform macro-level decisions about environmental targets such as those required to meet UN directives. However, in many African, Asian, and Latin American countries, researching and reporting company environmental performance is limited. This article serves as a contribution to filling the gap by presenting evidence of physical and chemical risk in Nigerian factories. One hundred and three factories with a total of 5,021 workers were studied. One hundred and twenty physical and chemical hazards were identified and the result shows a high number of workers exposed to such hazards. The study also reveals that workers' awareness level of chemical hazards was high. Yet the danger was perceived in behavioral terms, especially by manufacturing firms, which tend to see environmental investment in an increasingly global economy as detrimental to profitability.

  10. Engineering the smart factory

    Science.gov (United States)

    Harrison, Robert; Vera, Daniel; Ahmad, Bilal

    2016-10-01

    The fourth industrial revolution promises to create what has been called the smart factory. The vision is that within such modular structured smart factories, cyber-physical systems monitor physical processes, create a virtual copy of the physical world and make decentralised decisions. This paper provides a view of this initiative from an automation systems perspective. In this context it considers how future automation systems might be effectively configured and supported through their lifecycles and how integration, application modelling, visualisation and reuse of such systems might be best achieved. The paper briefly describes limitations in current engineering methods, and new emerging approaches including the cyber physical systems (CPS) engineering tools being developed by the automation systems group (ASG) at Warwick Manufacturing Group, University of Warwick, UK.

  11. The TRIUMF KAON Factory

    International Nuclear Information System (INIS)

    Craddock, M.

    1989-05-01

    TRIUMF has been awarded $11M for a one-year pre-construction Engineering Design and Impact Study of the KAON Factory. This will enable prototypes of many accelerator components to be built and the design of the accelerators and the layout of the experimental areas to be reviewed. The building and tunnel designs will be finalized, environmental, legal and economic impact studies carried out, and international involvement pursued further

  12. Automation in the factory

    Energy Technology Data Exchange (ETDEWEB)

    Hatvany, J

    1984-05-01

    There are now about 100000 computers in the manufacturing plants of the world, but the thirty-year old dream of the computer-controlled factory is only now beginning to materialize. With the advent of advanced microprocessor technology of distributed systems based on local area networking and of supervisory and diagnostic systems utilizing artificial intelligence techniques, computer-integrated manufacturing (CIM) has today become a realistic aim. 6 references.

  13. SLAC B Factory computing

    International Nuclear Information System (INIS)

    Kunz, P.F.

    1992-02-01

    As part of the research and development program in preparation for a possible B Factory at SLAC, a group has been studying various aspects of HEP computing. In particular, the group is investigating the use of UNIX for all computing, from data acquisition, through analysis, and word processing. A summary of some of the results of this study will be given, along with some personal opinions on these topics

  14. Repeated assessment of orthotopic glioma pO2 by multi-site EPR oximetry: A technique with the potential to guide therapeutic optimization by repeated measurements of oxygen

    Science.gov (United States)

    Khan, Nadeem; Mupparaju, Sriram; Hou, Huagang; Williams, Benjamin B.; Swartz, Harold

    2011-01-01

    Tumor hypoxia plays a vital role in therapeutic resistance. Consequently, measurements of tumor pO2 could be used to optimize the outcome of oxygen-dependent therapies, such as, chemoradiation. However, the potential optimizations are restricted by the lack of methods to repeatedly and quantitatively assess tumor pO2 during therapies, particularly in gliomas. We describe the procedures for repeated measurements of orthotopic glioma pO2 by multi-site electron paramagnetic resonance (EPR) oximetry. This oximetry approach provides simultaneous measurements of pO2 at more than one site in the glioma and contralateral cerebral tissue. The pO2 of intracerebral 9L, C6, F98 and U251 tumors, as well as contralateral brain, were measured repeatedly for five consecutive days. The 9L glioma was well oxygenated with pO2 of 27 - 36 mm Hg, while C6, F98 and U251 glioma were hypoxic with pO2 of 7 - 12 mm Hg. The potential of multi-site EPR oximetry to assess temporal changes in tissue pO2 was investigated in rats breathing 100% O2. A significant increase in F98 tumor and contralateral brain pO2 was observed on day 1 and day 2, however, glioma oxygenation declined on subsequent days. In conclusion, EPR oximetry provides the capability to repeatedly assess temporal changes in orthotopic glioma pO2. This information could be used to test and optimize the methods being developed to modulate tumor hypoxia. Furthermore, EPR oximetry could be potentially used to enhance the outcome of chemoradiation by scheduling treatments at times of increase in glioma pO2. PMID:22079559

  15. Validation and Reliability of a Smartphone Application for the International Prostate Symptom Score Questionnaire: A Randomized Repeated Measures Crossover Study

    Science.gov (United States)

    Shim, Sung Ryul; Sun, Hwa Yeon; Ko, Young Myoung; Chun, Dong-Il; Yang, Won Jae

    2014-01-01

    Background Smartphone-based assessment may be a useful diagnostic and monitoring tool for patients. There have been many attempts to create a smartphone diagnostic tool for clinical use in various medical fields but few have demonstrated scientific validity. Objective The purpose of this study was to develop a smartphone application of the International Prostate Symptom Score (IPSS) and to demonstrate its validity and reliability. Methods From June 2012 to May 2013, a total of 1581 male participants (≥40 years old), with or without lower urinary tract symptoms (LUTS), visited our urology clinic via the health improvement center at Soonchunhyang University Hospital (Republic of Korea) and were enrolled in this study. A randomized repeated measures crossover design was employed using a smartphone application of the IPSS and the conventional paper form of the IPSS. Paired t test under a hypothesis of non-inferior trial was conducted. For the reliability test, the intraclass correlation coefficient (ICC) was measured. Results The total score of the IPSS (P=.289) and each item of the IPSS (P=.157-1.000) showed no differences between the paper version and the smartphone version of the IPSS. The mild, moderate, and severe LUTS groups showed no differences between the two versions of the IPSS. A significant correlation was noted in the total group (ICC=.935, Psmartphones could participate. Conclusions The validity and reliability of the smartphone application version were comparable to the conventional paper version of the IPSS. The smartphone application of the IPSS could be an effective method for measuring lower urinary tract symptoms. PMID:24513507

  16. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  17. Predictive value of repeated measurements of luteal progesterone and estradiol levels in patients with intrauterine insemination and controlled ovarian stimulation.

    Science.gov (United States)

    Bakas, Panagiotis; Simopoulou, Maria; Giner, Maria; Drakakis, Petros; Panagopoulos, Perikles; Vlahos, Nikolaos

    2017-10-01

    The objective of this study is to assess if the difference of repeated measurements of estradiol and progesterone during luteal phase predict the outcome of intrauterine insemination. Prospective study. Reproductive clinic. 126 patients with infertility. Patients underwent controlled ovarian stimulation with recombinant FSH (50-150 IU/d). The day of IUI patients were given p.o natural micronized progesterone in a dose of 100 mg/tds. The area under the receiver characteristic operating curve (ROC curve) in predicting clinical pregnancy for % change of estradiol level on days 6 and 10 was 0.892 with 95% CI: 0.82-0.94. A cutoff value of change > -29.5% had a sensitivity of 85.7 with a specificity of 90.2. The corresponding ROC curve for % change of progesterone level was 0.839 with 95% CI: 0.76-0.90. A cutoff value of change > -33% had a sensitivity of 85 with a specificity of 75. The % change of estradiol and progesterone between days 6 and 10 has a predictive ability of pregnancy after IUI with COS of 89.2% and 83.4%, respectively. The addition of % of progesterone to % change of estradiol does not improve the predictive ability of % estradiol and should not be used.

  18. Comparing a single case to a control group - Applying linear mixed effects models to repeated measures data.

    Science.gov (United States)

    Huber, Stefan; Klein, Elise; Moeller, Korbinian; Willmes, Klaus

    2015-10-01

    In neuropsychological research, single-cases are often compared with a small control sample. Crawford and colleagues developed inferential methods (i.e., the modified t-test) for such a research design. In the present article, we suggest an extension of the methods of Crawford and colleagues employing linear mixed models (LMM). We first show that a t-test for the significance of a dummy coded predictor variable in a linear regression is equivalent to the modified t-test of Crawford and colleagues. As an extension to this idea, we then generalized the modified t-test to repeated measures data by using LMMs to compare the performance difference in two conditions observed in a single participant to that of a small control group. The performance of LMMs regarding Type I error rates and statistical power were tested based on Monte-Carlo simulations. We found that starting with about 15-20 participants in the control sample Type I error rates were close to the nominal Type I error rate using the Satterthwaite approximation for the degrees of freedom. Moreover, statistical power was acceptable. Therefore, we conclude that LMMs can be applied successfully to statistically evaluate performance differences between a single-case and a control sample. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Can father inclusive practice reduce paternal postnatal anxiety? A repeated measures cohort study using the hospital anxiety and depression scale

    Directory of Open Access Journals (Sweden)

    Tohotoa Jenny

    2012-07-01

    Full Text Available Abstract Background Perinatal research on anxiety and depression has primarily focused on mothers. We have limited knowledge of fathers’ anxiety during the perinatal period yet there is evidence that the parenting capacity of a person can be compromised by anxiety and depression. The purpose of this paper is to identify the impact of a father inclusive intervention on perinatal anxiety and depression. The prime focus of the intervention was to provide education and support to fathers of breastfeeding partners with the aim of increasing both initiation and duration of breastfeeding. Methods A repeated measures cohort study was conducted during a RCT that was implemented across eight public maternity hospitals in Perth, Western Australia between May 2008 and June 2009. A baseline questionnaire which included the Hospital Anxiety and Depression Scale (HADS was administered to all participants on the first night of their hospital based antenatal education program and was repeated at six weeks postnatal. SPSS version 17 was used for reporting descriptive results. Results The mean anxiety levels at baseline for the fathers in the intervention group (n=289 and control group (n=244 were 4.58 and 4.22 respectively. At 6 weeks postnatal (only matched pairs, intervention and control group were 3.93 and 3.79. More intervention group fathers self-rated less anxiety compared to the fathers in the control group from baseline to post test (p=0.048. Depression scores for intervention fathers at baseline (mean =1.09 and at six weeks (mean=1.09 were very similar to fathers in the control group at baseline (mean=1.11 and at six weeks (mean =1.07 with no significant changes. Conclusions Both intervention and control group fathers experienced some anxiety prior to the birth of their baby, but this was rapidly reduced at six weeks. Paternal anxiety is common to new fathers and providing them with information and strategies for problem-solving can increase their

  20. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  1. TRIUMF: Kaon factory physics

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The second TRIUMF Kaon Factory Physics Workshop was held on 10-14 August, 1981. About a hundred physicists participated in the meeting, which consisted of fifteen invited talks and four afternoon workshop sessions, and proved to be a stimulating and productive event. The discussions centred on identifying the most important physics that could be studied with a machine providing an increase in intensity of two orders of magnitude in primary proton beam over present accelerators in the energy range 8 to 20 GeV, and on establishing some preliminary guidelines on the desirable properties of secondary beams at such a machine

  2. KEK: B factory plans

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    To boost the study of B mesons (carrying the heavy b quark), the Japanese KEK Laboratory is looking to construct a B-meson 'factory'. B-mesons have revealed unexpected and important quark physics. Well-known examples are the long lifetime of the B-mesons, indicating a large gap between the third and second quark generation (compared to that between the second and the first), and relatively large mixing of the neutral B-meson and its antiparticle, now interpreted as being due to a heavy sixth ('top') quark

  3. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  4. Connectedness Among Chilean Adolescents: Factor Analysis of the Hemingway Measure of Adolescent Connectedness La Conectividad Entre Adolescentes Chilenos: Un Análisis Factorial de la Hemingway Measure of Adolescent Connectedness

    Directory of Open Access Journals (Sweden)

    Benedict T McWhirter

    2011-05-01

    Full Text Available The construct of connectedness was investigated among 390 Chilean adolescents using the Hemingway Measure of Adolescent Connectedness (Hemingway; Karcher, 2003. Participants were 7th-12th graders at an urban Santiago Catholic school. Results of a principal-axis exploratory factor analysis revealed an 11 factor structure that accounts for 61.92% of total explained variance of adolescent connectedness measured by the Hemingway, similar to results found in the adolescent samples in the United States. Two additional Hemingway subscales (connectedness to siblings and to boyfriend/girlfriend are also described. Correlations between domains of connectedness and additional data obtained from these adolescents, their parents, and their teachers support the construct validity of the measure in this Chilean sample. Connectedness is an important protective factor among adolescents across many national contexts and the Hemingway is a promising measure for use with Chilean adolescents.Se examinó el constructo conectividad en 390 adolescentes chilenos en un colegio urbano y católico de Santiago. Mediante un análisis factorial exploratorio de la escala Hemingway Measure of Adolescent Connectedness (Hemingway, Karcher, 2003 se observó una estructura de 11 factores que da cuenta de un 61,92% de la varianza explicada de la conectividad de los adolescentes medida por la escala Hemingway, lo cual es muy similar a los resultados obtenidos en muestras de adolescentes estadounidenses. También se describen dos subescalas adicionales (la conectividad con los/las hermanos/as y con los/las pololos/as. Las relaciones entre los factores de conectividad y los datos reportados por los adolescentes, sus padres y profesores contribuyen también a la validez de constructo de la escala en esta muestra chilena. Para los adolescentes de distintos contextos culturales la conectividad es un factor importante de protección y la escala Hemingway es un instrumento de uso prometedor

  5. Validation of the Psychometric Properties of the Self-Compassion Scale. Testing the Factorial Validity and Factorial Invariance of the Measure among Borderline Personality Disorder, Anxiety Disorder, Eating Disorder and General Populations.

    Science.gov (United States)

    Costa, Joana; Marôco, João; Pinto-Gouveia, José; Ferreira, Cláudia; Castilho, Paula

    2016-09-01

    During the last years, there has been a growing interest in self-compassion. Empirical evidences show that self-compassion is associated with psychological benefits among young adults and it might be considered a buffer factor in several mental disorders. The aim of this study was to validate the psychometric properties of the Self-compassion Scale (SCS: Neff, 2003a) after the initial lack of replicating the original six-factor structure. Data were collected from the overall database of a research centre (56 men and 305 women; mean age = 25.19) and comprised four groups: borderline personality disorder, anxiety disorder, eating disorder and general population. Confirmatory factor analysis supported a two-factor model (self-compassionate attitude versus self-critical attitude) with good internal consistencies, construct-related validity and external validity. Configural, weak measurement and structural invariance of the two-factor model of SCS were also shown. Findings support the generalizability of the two-factor model and show that both properties and interpretations of scores on self-compassion are equivalent across these population groups. Copyright © 2015 John Wiley & Sons, Ltd. A two-factor structure of SCS with strong psychometric validity was supported in clinical and non-clinical samples. Helping individuals with limited experiences of compassion to develop positive internal processing systems seems to be related with better mental health, self-acceptance and self-nurturing abilities. The non-probabilistic sampling limits the generalization of our conclusions. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Hadronic atoms at a kaon factory

    International Nuclear Information System (INIS)

    Leon, M.

    1982-01-01

    Beyond doubt, the advent of a kaon factory will be of immense significance for the study of hadronic atoms. Here we will discuss some classes of experiments that certainly can and will be done at a kaon factory, as well as some very interesting possibilities which deserve investigation. Among the certains we include the observation of hadronic x rays from kaonic and μ - atoms, for both Z greater than one and for the isotopes of hydrogen, mainly for strong interaction information. More conjectural is the possibility of measuring Xi - and Ω - x rays

  7. Particle physics prospects for the KAON factory

    International Nuclear Information System (INIS)

    Bryman, D.

    1989-05-01

    The Kaon Factory at TRIUMF will produce beams of kaons, antiprotons, neutrinos and other particles with a hundred-fold increase in intensity over existing machines in the 30 GeV region. This will make possible new high precision experiments designed to test current ideas as well as high sensitivity measurements which could potentially reveal new effects. A sample of particle physics experiments involving rare kaon decays, CP and T violation studies, neutrino properties and reactions and light quark spectroscopy which might take advantage of the new opportunities presented by the Kaon Factory is discussed

  8. Long-term, repeated measurements of mouse cortical microflow at the same region of interest with high spatial resolution.

    Science.gov (United States)

    Tomita, Yutaka; Pinard, Elisabeth; Tran-Dinh, Alexy; Schiszler, Istvan; Kubis, Nathalie; Tomita, Minoru; Suzuki, Norihiro; Seylaz, Jacques

    2011-02-04

    A method for long-term, repeated, semi-quantitative measurements of cerebral microflow at the same region of interest (ROI) with high spatial resolution was developed and applied to mice subjected to focal arterial occlusion. A closed cranial window was chronically implanted over the left parieto-occipital cortex. The anesthetized mouse was placed several times, e.g., weekly, under a dynamic confocal microscope, and Rhodamine B-isothiocyanate-dextran was each time intravenously injected as a bolus, while microflow images were video recorded. Left and right tail veins were sequentially catheterized in a mouse three times at maximum over a 1.5 months' observation period. Smearing of the input function resulting from the use of intravenous injection was shown to be sufficiently small. The distal middle cerebral artery (MCA) was thermocoagulated through the cranial window in six mice, and five sham-operated mice were studied in parallel. Dye injection and video recording were conducted four times in this series, i.e., before and at 10 min, 7 and 30 days after sham operation or MCA occlusion. Pixelar microflow values (1/MTT) in a matrix of approximately 50×50 pixels were displayed on a two-dimensional (2-D) map, and the frequency distribution of the flow values was also calculated. No significant changes in microflow values over time were detected in sham-operated mice, while the time course of flow changes in the ischemic penumbral area in operated mice was similar to those reported in the literature. This method provides a powerful tool to investigate long-term changes in mouse cortical microflow under physiological and pathological conditions. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Interactional justice at work is related to sickness absence: a study using repeated measures in the Swedish working population.

    Science.gov (United States)

    Leineweber, Constanze; Bernhard-Oettel, Claudia; Peristera, Paraskevi; Eib, Constanze; Nyberg, Anna; Westerlund, Hugo

    2017-12-08

    Research has shown that perceived unfairness contributes to higher rates of sickness absence. While shorter, but more frequent periods of sickness absence might be a possibility for the individual to get relief from high strain, long-term sickness absence might be a sign of more serious health problems. The Uncertainty Management Model suggests that justice is particularly important in times of uncertainty, e.g. perceived job insecurity. The present study investigated the association between interpersonal and informational justice at work with long and frequent sickness absence respectively, under conditions of job insecurity. Data were derived from the 2010, 2012, and 2014 biennial waves of the Swedish Longitudinal Occupational Survey of Health (SLOSH). The final analytic sample consisted of 19,493 individuals. We applied repeated measures regression analyses through generalized estimating equations (GEE), a method for longitudinal data that simultaneously analyses variables at different time points. We calculated risk of long and frequent sickness absence, respectively in relation to interpersonal and informational justice taking perceptions of job insecurity into account. We found informational and interpersonal justice to be associated with risk of long and frequent sickness absence independently of job insecurity and demographic variables. Results from autoregressive GEE provided some support for a causal relationship between justice perceptions and sickness absence. Contrary to expectations, we found no interaction between justice and job insecurity. Our results underline the need for fair and just treatment of employees irrespective of perceived job insecurity in order to keep the workforce healthy and to minimize lost work days due to sickness absence.

  10. Comparison of diet measures from a food-frequency questionnaire with measures from repeated 24-hour dietary recalls. The Norwegian Women and Cancer Study.

    Science.gov (United States)

    Hjartåker, Anette; Andersen, Lene Frost; Lund, Eiliv

    2007-10-01

    To compare diet measures from a food-frequency questionnaire (FFQ) with measures from 24-hour dietary recalls (24HDRs). The participants answered an FFQ after completing four, repeated 24HDRs during a year. Norway, nationwide. Of 500 women randomly selected from The Norwegian Women and Cancer Study (the Norwegian arm of the European Prospective Investigation into Cancer and Nutrition), 286 agreed to participate and 238 completed the study. On the group level, the FFQ overestimated absolute intake in seven and underestimated intake in six of 21 food groups. Intakes of energy, fat, added sugar and alcohol were lower in the FFQ than in the 24HDRs, whereas intake of fibre was higher. Spearman's rank correlation coefficient ranged from 0.13 (desserts) to 0.82 (coffee) for foods, and from 0.25 (beta-carotene) to 0.67 (alcohol) for nutrients. Three per cent of the observations on nutrient intake fell in the opposite quintile when classified according to the FFQ as compared with the 24HDR. The median calibration coefficient, calculated by regression of the 24HDR data on the FFQ data, was 0.57 for foods and 0.38 for nutrients. The FFQ's ability to rank subjects was good for foods eaten frequently and fairly good for macronutrients in terms of energy percentages. Weaker ranking abilities were seen for foods eaten infrequently and for some micronutrients. The results underline the necessity of performing measurement error corrections.

  11. Deciding WQO for factorial languages

    KAUST Repository

    Atminas, Aistis; Lozin, Vadim V.; Moshkov, Mikhail

    2013-01-01

    A language is factorial if it is closed under taking factors (i.e. contiguous subwords). Every factorial language can be described by an antidictionary, i.e. a minimal set of forbidden factors. We show that the problem of deciding whether a factorial language given by a finite antidictionary is well-quasi-ordered under the factor containment relation can be solved in polynomial time. © 2013 Springer-Verlag Berlin Heidelberg.

  12. Deciding WQO for factorial languages

    KAUST Repository

    Atminas, Aistis

    2013-04-05

    A language is factorial if it is closed under taking factors (i.e. contiguous subwords). Every factorial language can be described by an antidictionary, i.e. a minimal set of forbidden factors. We show that the problem of deciding whether a factorial language given by a finite antidictionary is well-quasi-ordered under the factor containment relation can be solved in polynomial time. © 2013 Springer-Verlag Berlin Heidelberg.

  13. Does repeat Hb measurement within 2 hours after a normal initial Hb in stable trauma patients add value to trauma evaluation?

    NARCIS (Netherlands)

    Sierink, Joanne C.; Joosse, Pieter; de Castro, Steve M. M.; Schep, Niels W. L.; Goslings, J. Carel

    2014-01-01

    In our level I trauma center, it is considered common practice to repeat blood haemoglobin measurements in patients within 2 h after admission. However, the rationale behind this procedure is elusive and can be considered labour-intensive, especially in patients in whom haemorrhaging is not to be

  14. Assessment of Work Zone Noise Levels at a Cement Factory in ...

    African Journals Online (AJOL)

    Assessment of Work Zone Noise Levels at a Cement Factory in Tanga, Tanzania. ... measured in most production sections exceeded the allowed limit value of 85 ... Keywords: Noise levels, Noise exposure, Cement factory, Survey, Tanzania ...

  15. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  16. KEK: B factory

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    After more than three years of intensive evaluation, the Japanese government has approved the conversion of the TRISTAN electronpositron collider at the national KEK Laboratory to a two-ring asymmetric B-meson factory. The project will take about five years to complete. Initial construction will proceed while TRISTAN experiments continue datataking, expected to continue until summer 1995. When it becomes operational in 1998, the new facility (TRISTAN II) will be capable of producing more than ten million B meson pairs each year. Detailed studies of their decay properties are expected to reveal answers to the long-standing puzzle of the violation of CP symmetry - combined left-right reversal and particle-antiparticle substitution

  17. SRF for neutrino factories

    International Nuclear Information System (INIS)

    Padamsee, H.

    2003-01-01

    The Neutrino Factory calls for nearly 500 meters of 200 MHz SRF cavities to provide 7.5 GV. Such a facility is more demanding than the largest SRF installation to date, i.e., LEP-II, where 500 m of niobium-coated copper cavities provided more than 3 GV of acceleration. Based on the high real estate gradient desired to minimize muon loss, superconducting cavities are selected to provide active gradients of 15 - 17 MV/m, and a real estate gradient of 7.5 MV/m. At such high gradients, the peak RF power demand for copper cavities would become prohibitively expensive. By virtue of low losses, SC cavities can be filled slowly (rise time 3 ms) reducing the peak power demand to roughly half MW per cell. (author)

  18. Positron Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Sohei; Sunaga, Hiromi; Kaneko, Hirohisa; Kawasuso, Atsuo; Masuno, Shin-ichi; Takizawa, Haruki; Yotsumoto, Keiichi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    We have started drafting a construction program for the Positron Factory, in which linac-based intense monoenergetic positron beams are planned to be applied for materials science, biotechnology and basic physics and chemistry. A technical survey study confirmed the feasibility of manufacturing a dedicated electron linac of 100 kW class with a beam energy of 100 MeV, which will produce a world-highest monoenergetic positron beam of more than 10{sup 10}/sec in intensity. A self-driven rotating converter (electrons to positrons and photons) suitable for the high power electron beam was devised and successfully tested. The practicability of simultaneous extraction of multi-channel monoenergetic positron beams with multiple moderator assemblies, which had been originated on the basis of a Monte Carlo simulation, was demonstrated by an experiment using an electron linac. An efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is also proposed. (author)

  19. Measuring the Extent of the Environmental Pollution in the Waters of the Al-Diwani River by Certain Trace Elements Resulting from Al-Diwani Textile Factory Using Spectroscopic Methods

    Directory of Open Access Journals (Sweden)

    Al-Rufaie Mohauman Mahammad

    2016-04-01

    Full Text Available The textile industry is a key source of pollution in fresh water. The concentration of key heavy metal pollutants (cobalt, nickel, lead, mercury, cadmium, copper, and iron as well as pH value and conductivity were measured in water samples taken from the input and output (waste water of Al-Diwani textile factory on the Al-Diwani River, Iraq. These samples were measured using two methods, flame atomic absorption spectrophotometry and spectrometry. This paper considers the relative effectiveness of each method for measuring the concentrations of the elements, and discusses which method is best for which element. It was found that the first method is more accurate for measuring the concentrations for all elements except iron.

  20. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah

    2017-01-01

    was calculated using the density of bone mineral content, fat, and lean mass. The repeatability of the volume of the lower limb and regional thigh and lower leg tissue composition (bone mineral content, fat, and lean mass) was good with intraclass correlation coefficient values of 0.97 to 0.99, and narrow limits...

  1. Recommendations for analysis of repeated-measures designs: testing and correcting for sphericity and use of manova and mixed model analysis.

    Science.gov (United States)

    Armstrong, Richard A

    2017-09-01

    A common experimental design in ophthalmic research is the repeated-measures design in which at least one variable is a within-subject factor. This design is vulnerable to lack of 'sphericity' which assumes that the variances of the differences among all possible pairs of within-subject means are equal. Traditionally, this design has been analysed using a repeated-measures analysis of variance (RM-anova) but increasingly more complex methods such as multivariate anova (manova) and mixed model analysis (MMA) are being used. This article surveys current practice in the analysis of designs incorporating different factors in research articles published in three optometric journals, namely Ophthalmic and Physiological Optics (OPO), Optometry and Vision Science (OVS), and Clinical and Experimental Optometry (CXO), and provides advice to authors regarding the analysis of repeated-measures designs. Of the total sample of articles, 66% used a repeated-measures design. Of those articles using a repeated-measures design, 59% and 8% analysed the data using RM-anova or manova respectively and 33% used MMA. The use of MMA relative to RM-anova has increased significantly since 2009/10. A further search using terms to select those papers testing and correcting for sphericity ('Mauchly's test', 'Greenhouse-Geisser', 'Huynh and Feld') identified 66 articles, 62% of which were published from 2012 to the present. If the design is balanced without missing data then manova should be used rather than RM-anova as it gives better protection against lack of sphericity. If the design is unbalanced or with missing data then MMA is the method of choice. However, MMA is a more complex analysis and can be difficult to set up and run, and care should be taken first, to define appropriate models to be tested and second, to ensure that sample sizes are adequate. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  2. Confirmatory factorial analysis of TEOSQp / Análise factorial confirmatória do TEOSQp

    Directory of Open Access Journals (Sweden)

    Helder M. Fernandes

    2010-01-01

    Full Text Available The present research assessed the reliability, factorial validity and measurement invariance (by gender of the Portuguese version of TEOSQ –Task and Ego Orientation in Sport Questionnaire (Fonseca & Biddle, 2001. Data were collected from 1010 physical education students with a mean age of 15.42 ( SD=1.91. Factorial and invariance measurements were tested via confirmatory factorial analysis. Results supported internal consistency for the two proposed subscales (task and ego. Based on modification indices and theoretical justification the TEOSQ p was reduced to 12 items with better goodness-of-fit indices for the oblique model. The results of gender invariance did not provide full empirical support to the multi-group equivalence assumption, being suggested that TEOSQ p does not measure in the same way goal orientations for boys (orthogonal model and girls (oblique model. In light of these results, conceptual, empirical and practical issues were discussed.

  3. Secondhand tobacco smoke exposure and heart rate variability and inflammation among non-smoking construction workers: a repeated measures study.

    Science.gov (United States)

    Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M

    2013-10-02

    Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated

  4. Ambient temperature and cardiovascular biomarkers in a repeated-measure study in healthy adults: A novel biomarker index approach.

    Science.gov (United States)

    Wu, Shaowei; Yang, Di; Pan, Lu; Shan, Jiao; Li, Hongyu; Wei, Hongying; Wang, Bin; Huang, Jing; Baccarelli, Andrea A; Shima, Masayuki; Deng, Furong; Guo, Xinbiao

    2017-07-01

    Associations of ambient temperature with cardiovascular morbidity and mortality have been well documented in numerous epidemiological studies, but the underlying pathways remain unclear. We investigated whether systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function may be the mechanistic pathways associated with ambient temperature. Forty study participants underwent repeated blood collections for 12 times in Beijing, China in 2010-2011. Ambient temperature and air pollution data were measured in central monitors close to student residences. We created five indices as the sum of weighted biomarker percentiles to represent the overall levels of 15 cardiovascular biomarkers in five pathways (systemic inflammation: hs-CRP, TNF-α and fibrinogen; coagulation: fibrinogen, PAI-1, tPA, vWF and sP-selectin; systemic oxidative stress: Ox-LDL and sCD36: antioxidant activity: EC-SOD and GPX1; and endothelial function: ET-1, E-selectin, ICAM-1 and VCAM-1). We used generalized mixed-effects models to estimate temperature effects controlling for air pollution and other covariates. There were significant decreasing trends in the adjusted means of biomarker indices over the lowest to the highest quartiles of daily temperatures before blood collection. A 10°C decrease at 2-d average daily temperature were associated with increases of 2.5% [95% confidence interval (CI): 0.7, 4.2], 1.6% (95% CI: 0.1, 3.1), 2.7% (95% CI: 0.5, 4.8), 5.5% (95% CI: 3.8, 7.3) and 2.0% (95% CI: 0.3, 3.8) in the indices for systemic inflammation, coagulation, systemic oxidative stress, antioxidant activity and endothelial function, respectively. In contrast, the associations between ambient temperature and individual biomarkers had substantial variation in magnitude and strength. The altered cardiovascular biomarker profiles in healthy adults associated with ambient temperature changes may help explain the temperature-related cardiovascular morbidity

  5. General B factory design considerations

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1992-12-01

    We describe the general considerations that go into the design of an asymmetric B factory collider. Justification is given for the typical parameters of such a facility, and the physics and technology challenges that arise from these parameter choices are discussed. Cost and schedule issues for a B factory are discussed briefly. A summary of existing proposals is presented, noting their similarities and differences

  6. Repeating Marx

    DEFF Research Database (Denmark)

    Fuchs, Christian; Monticelli, Lara

    2018-01-01

    This introduction sets out the context of the special issue “Karl Marx @ 200: Debating Capitalism & Perspectives for the Future of Radical Theory”, which was published on the occasion of Marx’s bicentenary on 5 May 2018. First, we give a brief overview of contemporary capitalism’s development...... and its crises. Second, we argue that it is important to repeat Marx today. Third, we reflect on lessons learned from 200 years of struggles for alternatives to capitalism. Fourth, we give an overview of the contributions in this special issue. Taken together, the contributions in this special issue show...... that Marx’s theory and politics remain key inspirations for understanding exploitation and domination in 21st-century society and for struggles that aim to overcome these phenomena and establishing a just and fair society. We need to repeat Marx today....

  7. Deployment Repeatability

    Science.gov (United States)

    2016-08-31

    large cohort of trials to spot unusual cases. However, deployment repeatability is inherently a nonlinear phenomenon, which makes modeling difficult...and GEMS tip position were both tracked during ground testing by a laser target tracking system. Earlier SAILMAST testing in 2005 [8] used...recalls the strategy used by SRTM, where a constellation of lights was installed at the tip of the boom and a modified star tracker was used to track tip

  8. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor) variables? This question was answered using generalized...... involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...

  9. The Low-Energy Neutrino Factory

    International Nuclear Information System (INIS)

    Brass, Alan; Geer, Steve; Ellis, Malcolm; Mena, Olga; Pascoli, Silvia

    2008-01-01

    To date most studies of Neutrino Factories have focused on facilities where the energy of the muon in the storage ring has been in the range of 25-50 GeV. In this paper we present a concept for a Low-Energy (∼ 4 GeV) neutrino factory. For baselines of O(1000 km), the rich oscillation pattern at low neutrino interaction energy (0.5 - ∼3 GeV) provides the unique performance of this facility with regard to its sensitivity to CP violation and the determination of the neutrino mass hierarchy. A unique neutrino detector is needed, however, in order to exploit this oscillation pattern. We will describe the basic accelerator facility, demonstrate the methodology of the analysis and give an estimate on how well the Low-Energy neutrino factory can measure θ 13 , CP violation and the mass hierarchy. We will also describe the detector concept that is used, show a preliminary analysis regarding its performance and indicate what R and D is still needed. Finally we will show how the Low-Energy neutrino factory could be a step towards an energy frontier muon collider.

  10. The eldercare factory.

    Science.gov (United States)

    Sharkey, Noel; Sharkey, Amanda

    2012-01-01

    Rapid advances in service robotics together with dramatic shifts in population demographics have led to the notion that technology may be the answer to our eldercare problems. Robots are being developed for feeding, washing, lifting, carrying and mobilising the elderly as well as monitoring their health. They are also being proposed as a substitute for companionship. While these technologies could accrue major benefits for society and empower the elderly, we must balance their use with the ethical costs. These include a potential reduction in human contact, increased feeling of objectification and loss of control, loss of privacy and personal freedom as well as deception and infantilisation. With appropriate guidelines in place before the introduction of robots en masse into the care system, robots could improve the lives of the elderly, reducing their dependence and creating more opportunities for social interaction. Without forethought, the elderly may find themselves in a barren world of machines, a world of automated care: a factory for the elderly. Copyright © 2011 S. Karger AG, Basel.

  11. The TRIUMF KAON factory

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1991-05-01

    The TRIUMF KAON Factory is designed to produce beams of kaons, antiprotons, other hadrons and neutrinos 100 times more intense, or cleaner, than are available now, for a broad range of particle and nuclear physics experiments. This will require a 100 μA beam of 30 GeV protons, to be produced by an interleaved sequence of two fast-cycling synchrotrons and three storage rings, with the existing TRIUMF H - cyclotron as injector. An $11-million preconstruction study has enabled the overall design to be reviewed and prototypes of various components to be built and evaluated -fast-cycling dipole and quadrupole magnets, a dual-frequency magnet power supply, ceramic beam pipes with internal RF shields, an RF cavity (using perpendicular bias), an extraction kicker, and RF beam chopper, and production targets. Environmental, industrial and economic impact studies have also been completed and the cost estimates and schedule updated. The total cost of $708 million (Canadian) will be shared equally between Canada, British Columbia (already approved) and international contributors. The federal decision is expected shortly. (Author) 29 refs., 5 figs

  12. The TRIUMF KAON Factory

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1990-11-01

    The TRIUMF KAON Factory is designed to produce beams of kaons, antiprotons, other hadrons and neutrinos 100 times more intense, or cleaner, than are available now, for a broad range of experiments in particle and nuclear physics. This will require a 100 μA beam of 30 GeV protons, to be produced by an interleaved sequence of two fast-cycling synchrotrons and three storage rings, with the existing TRIUMF H - cyclotron as injector. An $11-million preconstruction study has enabled the overall design to be reviewed and prototypes of various accelerator components to be built and evaluated. Environmental, industrial and economic impact studies have also been completed. Payment of one-third of the total cost of $708 million (Canadian) has been approved by the government of British Columbia; a further third is expected from international sources, on the basis of inter-governmental consultations. A decision on the final third is expected from the government of Canada before the end of 1990. (Author) (15 refs., 7 figs.)

  13. AutoPyFactory: A Scalable Flexible Pilot Factory Implementation

    International Nuclear Information System (INIS)

    Caballero, J; Hover, J; Love, P; Stewart, G A

    2012-01-01

    The ATLAS experiment at the CERN LHC is one of the largest users of grid computing infrastructure, which is a central part of the experiment's computing operations. Considerable efforts have been made to use grid technology in the most efficient and effective way, including the use of a pilot job based workload management framework. In this model the experiment submits ‘pilot’ jobs to sites without payload. When these jobs begin to run they contact a central service to pick-up a real payload to execute. The first generation of pilot factories were usually specific to a single Virtual Organization (VO), and were bound to the particular architecture of that VO's distributed processing. A second generation provides factories which are more flexible, not tied to any particular VO, and provide new and improved features such as monitoring, logging, profiling, etc. In this paper we describe this key part of the ATLAS pilot architecture, a second generation pilot factory, AutoPyFactory. AutoPyFactory has a modular design and is highly configurable. It is able to send different types of pilots to sites and exploit different submission mechanisms and queue characteristics. It is tightly integrated with the PanDA job submission framework, coupling pilot flow to the amount of work the site has to run. It gathers information from many sources in order to correctly configure itself for a site and its decision logic can easily be updated. Integrated into AutoPyFactory is a flexible system for delivering both generic and specific job wrappers which can perform many useful actions before starting to run end-user scientific applications, e.g., validation of the middleware, node profiling and diagnostics, and monitoring. AutoPyFactory also has a robust monitoring system that has been invaluable in establishing a reliable pilot factory service for ATLAS.

  14. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  15. PTSD and DNA Methylation in Select Immune Function Gene Promoter Regions: A Repeated Measures Case-control Study of U.S. Military Service Members

    Science.gov (United States)

    2013-06-24

    other relevant exposures which may influ- ence DNA methylation , such as dietary factors ( folate , vitamin B12 intake) (Fenech, 2001; Piyathilake and...ARTICLE published: 24 June 2013 doi: 10.3389/fpsyt.2013.00056 PTSD and DNA methylation in select immune function gene promoter regions: a repeated measures...largely unknown. Dis- tinct expression signatures for PTSD have been found, in particular for immune activation transcripts. DNA methylation may be

  16. Effects of annealing on the sensitivity of LiF TLD-100 after repeated use for low dose measurements

    International Nuclear Information System (INIS)

    Ogunleye, O.T.; Richmond, R.G.

    1987-01-01

    The changes in sensitivity of LiF TLD-100 extruded ribbons subjected to repeated use up to 100 times were investigated. Three different annealing regimes were compared. The dosemeters were annealed at 400 0 C followed by (i) a slow or (ii) fast cooling to room temperature or (iii) utilising a 20 s readout process in the reader without a high temperature annealing at 400 0 C. Each of the three groups consisted of two sets of 20 chips each, with one set receiving 500 μ Gy of 90 Sr beta radiation and the other unirradiated. Sensitivity evaluations were performed every five cycles through the first 50 cycles, and on each tenth cycle thereafter. On the average, the fast cooled group maintained their integrity best, while a maximum variation in sensitivity of about 15% was observed in the irradiated set of the slowly cooled group. A permanent increase in sensitivity of at least 10% was observed for the set of dosemeters receiving radiation without annealing. Glow curve analyses showed an increase in the ratio of peaks 4 and 5 with repeated use of this group. (author)

  17. Neutrino Factory Targets and the MICE Beam

    International Nuclear Information System (INIS)

    Walaron, Kenneth A.

    2007-01-01

    The future of particle physics in the next 20 years must include detailed study of neutrinos. The first proof of physics beyond the Standard Model of particle physics is evident in results from recent neutrino experiements which imply that neutrinos have mass and flavour mixing. The Neutrino Factory is the leading contender to measure precisely the neutrino mixing parameters to probe beyond the Standard Model physics.

  18. Photon factory activity report, 1992

    International Nuclear Information System (INIS)

    1993-01-01

    This issue is the annual report of the Photon Factory, National laboratory of High Energy Physics. First, the outline of the Photon Factory is presented. Injector linac, light source, beamlines and instrumentation, the Tristan synchrotron radiation facility at the accumulation ring, and the Tristan super light facility are described in detail. The facility is open to researchers. The user's reports are collected as well. (J.P.N.) (435 refs.)

  19. Atomic Energy (factories) rules: 1988

    International Nuclear Information System (INIS)

    1988-01-01

    These rules are made by the Central Government under the Factories Act, 1948 and extend to all factories engaged in carrying out the purposes of the Atomic Energy Act, 1962. The rules cover the requirements of inspecting staff, health aspects, personnel safety, personnel welfare, working hours, employment of young persons, special provisions in case of dangerous manufacturing processes or operations, supplemental rules for administrative aspects and special powers of competent authority. (M.G.B.)

  20. Photon factory activity report, 1993

    International Nuclear Information System (INIS)

    1994-01-01

    This issue is the annual report of the Photon Factory, National Laboratory of High Energy Physics. First the outline of the Photon Factory is presented. Injector linac, light source, beamlines and instrumentation, synchrotron radiation facility at the Tristan accumulation ring, and the Tristan super light facility are described in detail. The facility is open to researchers. The user's reports are collected as well. (J.P.N.)

  1. Muon colliders and neutrino factories

    Energy Technology Data Exchange (ETDEWEB)

    Geer, S.; /Fermilab

    2010-09-01

    Over the last decade there has been significant progress in developing the concepts and technologies needed to produce, capture and accelerate {Omicron}(10{sup 21}) muons/year. This development prepares the way for a new type of neutrino source (Neutrino Factory) and a new type of very high energy lepton-antilepton collider (Muon Collider). This article reviews the motivation, design and R&D for Neutrino Factories and Muon Colliders.

  2. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  3. Performance Analysis of Measurement Inaccuracies of IMU/GPS on Airborne Repeat-pass Interferometric SAR in the Presence of Squint

    Directory of Open Access Journals (Sweden)

    Deng Yuan

    2014-08-01

    Full Text Available In the MOtion COmpensation (MOCO approach to airborne repeat-pass interferometric Synthetic Aperture Radar (SAR based on motion measurement data, the measurement inaccuracies of Inertial Measurement Unit/Global Positioning System (IMU/GPS and the positioning errors of the target, which may contribute to the residual uncompensated motion errors, affect the imaging result and interferometric measurement. Considering the effects of the two types of error, this paper builds a mathematical model of residual motion errors in presence of squint, and analyzes the effects on the residual motion errors induced by the measurement inaccuracies of IMU/GPS and the positioning errors of the target. In particular, the effects of various measurement inaccuracies of IMU/GPS on interferometric SAR image quality, interferometric phase, and digital elevation model precision are disscussed. Moreover, the paper quantitatively researches the effects of residual motion errors on airborne repeat-pass interferometric SAR through theoretical and simulated analyses and provides theoretical bases for system design and signal processing.

  4. Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds.

    Science.gov (United States)

    Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip

    2018-03-22

    To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.

  5. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  6. AutoPyFactory: A Scalable Flexible Pilot Factory Implementation

    CERN Document Server

    Caballero, J; The ATLAS collaboration; Love, P; Stewart, G

    2012-01-01

    The ATLAS experiment at the CERN LHC is one of the largest users of grid computing infrastructure, which is a central part of the experiment’s computing operations. Considerable efforts have been made to use grid technology in the most efficient and effective way, including the use of a pilot job based workload management framework. In this model the experiment submits ’pilot’ jobs to sites without payload. When these jobs begin to run they contact a central service to retrieve a real payload to execute. The first generation of pilot factories were usually specific to a single VO, and were bound to the particular architecture of that VO’s distributed processing. A second generation provides factories which are more flexible, not tied to any particular VO, and provide new or improved features such as monitoring, logging, profiling, etc. In this paper we describe this key part of the ATLAS pilot architecture, a second generation pilot factory, AutoPyFactory. AutoPyFactory has a modular design and is hig...

  7. (In)Consistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Science.gov (United States)

    Froio de Araujo Dias, Gabriela; da Eira Silva, Vinicius; de Salles Painelli, Vitor; Sale, Craig; Giannini Artioli, Guilherme; Gualano, Bruno; Saunders, Bryan

    2015-01-01

    Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB). 15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m) completed six cycling capacity tests at 110% of maximum power output (CCT110%) following ingestion of either 0.3 g∙kg-1BM of SB (4 trials) or placebo (PL, 2 trials). Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD) was recorded as the exercise outcome. SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001); absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05). Blood lactate was elevated following exercise in all trials (p ≤ 0.001), and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05), although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none. The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation. ClinicalTrials.gov NCT02474628.

  8. (InConsistencies in Responses to Sodium Bicarbonate Supplementation: A Randomised, Repeated Measures, Counterbalanced and Double-Blind Study.

    Directory of Open Access Journals (Sweden)

    Gabriela Froio de Araujo Dias

    Full Text Available Intervention studies do not account for high within-individual variation potentially compromising the magnitude of an effect. Repeat administration of a treatment allows quantification of individual responses and determination of the consistency of responses. We determined the consistency of metabolic and exercise responses following repeated administration of sodium bicarbonate (SB.15 physically active males (age 25±4 y; body mass 76.0±7.3 kg; height 1.77±0.05 m completed six cycling capacity tests at 110% of maximum power output (CCT110% following ingestion of either 0.3 g∙kg-1BM of SB (4 trials or placebo (PL, 2 trials. Blood pH, bicarbonate, base excess and lactate were determined at baseline, pre-exercise, post-exercise and 5-min post-exercise. Total work done (TWD was recorded as the exercise outcome.SB supplementation increased blood pH, bicarbonate and base excess prior to every trial (all p ≤ 0.001; absolute changes in pH, bicarbonate and base excess from baseline to pre-exercise were similar in all SB trials (all p > 0.05. Blood lactate was elevated following exercise in all trials (p ≤ 0.001, and was higher in some, but not all, SB trials compared to PL. TWD was not significantly improved with SB vs. PL in any trial (SB1: +3.6%; SB2 +0.3%; SB3: +2.1%; SB4: +6.7%; all p > 0.05, although magnitude-based inferences suggested a 93% likely improvement in SB4. Individual analysis showed ten participants improved in at least one SB trial above the normal variation of the test although five improved in none.The mechanism for improved exercise with SB was consistently in place prior to exercise, although this only resulted in a likely improvement in one trial. SB does not consistently improve high intensity cycling capacity, with results suggesting that caution should be taken when interpreting the results from single trials as to the efficacy of SB supplementation.ClinicalTrials.gov NCT02474628.

  9. The tau-charm factory: Experimental perspectives

    International Nuclear Information System (INIS)

    Perl, M.L.; Schindler, R.H.

    1991-09-01

    This report discusses the Tau-Charm Factory Concept; D and D S Physics at the Tau-Charm Factory; τ and ν τ Physics at the Tau-Charm Factory; and Charmonium, Gluonium and Light Quark Spectroscopy at the Tau-Charm Factory

  10. Very long Detection Times after High and repeated intake of Heroin and Methadone, measured in Oral Fluid

    Directory of Open Access Journals (Sweden)

    Vindenes V.

    2014-12-01

    Full Text Available When detection times for psychoactive drugs in oral fluid are reported, they are most often based on therapeutic doses administered in clinical studies. Repeated ingestions of high doses, as seen after drug abuse, are however likely to cause positive samples for extended time periods. Findings of drugs of abuse in oral fluid might lead to negative sanctions, and the knowledge of detection times of these drugs are important to ensure correct interpretation. The aim of this study was to investigate the detection times of opioids in oral fluid. 25 patients with a history of heavy drug abuse admitted to a detoxification ward were included. Oral fluid and urine were collected daily and, if the patient gave consent, a blood sample was drawn during the first five days after admission. Morphine, codeine and/or 6-monoacetyl morphine (6-MAM were found in oral fluid and/or urine from 20 patients. The maximum detection times in oral fluid for codeine, morphine and 6-MAM were 1, 3 and 8 days, respectively. Positive oral fluid samples were interspersed with negative samples, mainly for concentrations around cut off. Elimination curves for methadone in oral fluid were found for two subjects, and the detection times were 5 and 8 days. Oral fluid is likely to become a good method for detection of drug abuse in the future

  11. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  12. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK

    Directory of Open Access Journals (Sweden)

    Rosa Weiss Telles

    Full Text Available Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK. Material and methods: A test–retest design including 19 adults (38 knee images was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD values. Repeatability was assessed for IMD and joint space width (JSW measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively. Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV = 54.68%; intraclass correlation coefficient (ICC (95%CI = 0.59 (0.34–0.77]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI = 0.74 (0.55–0.85–0.94 (0.87–0.97]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.

  13. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  14. Violation of the Sphericity Assumption and Its Effect on Type-I Error Rates in Repeated Measures ANOVA and Multi-Level Linear Models (MLM).

    Science.gov (United States)

    Haverkamp, Nicolas; Beauducel, André

    2017-01-01

    We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The

  15. The Physics of the B Factories

    Energy Technology Data Exchange (ETDEWEB)

    Bevan, A.J. [Queen Mary Univ., London (United Kingdom); Golob, B. [Ljubljana Univ. (Slovenia). Faculty of Mathematics and Physics; J. Stefan Institute, Ljubljana (Slovenia); Mannel, T. [Siegen Univ. (Germany). Theoretische Physik 1; Collaboration: BABAR Collaboration; Belle Collaboration; and others

    2014-11-15

    The inspiration for this book came from Fran@cois le Diberder. During his term as spokesperson for BABAR he laid down a vision for the two B Factory detector collaborations, BABAR and Belle, to work together on a book that would describe the methodologies used and physics results obtained by those experiments. A key ideal emphasized from the outset was that this book should be written from a pedagogical perspective; it should be of interest to the student and expert alike. This vision was presented during a BABAR collaboration meeting on the island of Elba in May 2008 and a follow up Belle collaboration meeting at KEK, with visiting colleagues from the BABAR collaboration, and was embraced by the community. A number of workshops involving people from the theoretical community as well as the two collaborations were held on four continents over the following years. The resulting book, ''The Physics of the B Factories'', is a testament to the way that this concept captured the zeitgeist on both sides of the Pacific Ocean. This book is divided into three parts, the first of which provides a brief description of the B Factories, including a short (though not exhaustive) historical perspective, as well as descriptions of the detectors, ancillary data acquisition systems and data (re)processing systems that were built by the two detector collaborations in the late 1990's. The second part of the book discusses tools and methods that are frequently used when analyzing the data collected. These range from details of low level reconstruction algorithms and abstract summaries of statistical methods to high level prescriptions used when evaluating systematic uncertainties on measurements of observables. The third part of the book is devoted to physics results. This includes sufficient theoretical discussion in order for the reader to understand the context of the work being described. We are indebted to our colleagues from the theoretical community who

  16. The Physics of the B Factories

    International Nuclear Information System (INIS)

    Bevan, A.J.; Golob, B.; Mannel, T.

    2014-01-01

    The inspiration for this book came from Fran@cois le Diberder. During his term as spokesperson for BABAR he laid down a vision for the two B Factory detector collaborations, BABAR and Belle, to work together on a book that would describe the methodologies used and physics results obtained by those experiments. A key ideal emphasized from the outset was that this book should be written from a pedagogical perspective; it should be of interest to the student and expert alike. This vision was presented during a BABAR collaboration meeting on the island of Elba in May 2008 and a follow up Belle collaboration meeting at KEK, with visiting colleagues from the BABAR collaboration, and was embraced by the community. A number of workshops involving people from the theoretical community as well as the two collaborations were held on four continents over the following years. The resulting book, ''The Physics of the B Factories'', is a testament to the way that this concept captured the zeitgeist on both sides of the Pacific Ocean. This book is divided into three parts, the first of which provides a brief description of the B Factories, including a short (though not exhaustive) historical perspective, as well as descriptions of the detectors, ancillary data acquisition systems and data (re)processing systems that were built by the two detector collaborations in the late 1990's. The second part of the book discusses tools and methods that are frequently used when analyzing the data collected. These range from details of low level reconstruction algorithms and abstract summaries of statistical methods to high level prescriptions used when evaluating systematic uncertainties on measurements of observables. The third part of the book is devoted to physics results. This includes sufficient theoretical discussion in order for the reader to understand the context of the work being described. We are indebted to our colleagues from the theoretical community who have helped us achieve

  17. IMPLANTABLE RESONATORS – A TECHNIQUE FOR REPEATED MEASUREMENT OF OXYGEN AT MULTIPLE DEEP SITES WITH IN VIVO EPR

    Science.gov (United States)

    Li, Hongbin; Hou, Huagang; Sucheta, Artur; Williams, Benjamin B.; Lariviere, Jean P.; Khan, Nadeem; Lesniewski, Piotr N.; Swartz, Harold M.

    2013-01-01

    EPR oximetry using implantable resonators allow measurements at much deeper sites than are possible with surface resonators (> 80 mm vs. 10 mm) and have greater sensitivity at any depth. We report here the development of an improvement of the technique that now enables us to obtain the information from multiple sites and at a variety of depths. The measurements from the various sites are resolved using a simple magnetic field gradient. In the rat brain multi-probe implanted resonators measured pO2 at several sites simultaneously for over 6 months to record under normoxic, hypoxic and hyperoxic conditions. This technique also facilitates measurements in moving parts of the animal such as the heart, because the orientation of the paramagnetic material relative to the sensitive small loop is not altered by the motion. The measured response is very fast, enabling measurements in real time of physiological and pathological changes such as experimental cardiac ischemia in the mouse heart. The technique also is quite useful for following changes in tumor pO2, including applications with simultaneous measurements in tumors and adjacent normal tissues. PMID:20204802

  18. Engineering the Polyketide Cell Factory

    DEFF Research Database (Denmark)

    Mølgaard, Louise

    sufficient titers. To improve the production of polyketides biological engineering principles have been applied for the development and engineering of microbial polyketide cell factories. The two biological hosts used for heterologous polyketide production were Aspergillus nidulans and Saccharomyces...... phosphopantetheinylase (PPTase). This versatile vector system can easily be used for expression of other polyketides of interest as well as extended to express whole gene clusters. After achieving proof of principle in terms of expression, the polyketide cell factory must be optimized. The optimization can be achieved...... characterization in bioreactors revealed that the yields of 6-MSA on biomass increased albeit not significantly. As a result of this it may be argued that there is still more work to be done in terms of model building in A. nidulans. Utilizing another well-established cell factory S. cerevisiae the capabilities...

  19. Photon Factory activity report, 1991

    International Nuclear Information System (INIS)

    1992-01-01

    The Photon Factory is a national synchrotron radiation research facility affiliated with the National Laboratory for High Energy Physics located in Tsukuba Science City. The Photon Factory consists of a 2.5 GeV electron/positron linear accelerator, a 2.5 GeV electron/positron storage ring, beam lines and experimental stations. All the facilities for synchrotron radiation research are open to scientists. A part of the accumulation ring of the TRISTAN main ring has been used as a synchrotron radiation source in the energy range from 5.8 to 6.5 GeV. The Photon Factory is composed of three divisions of Injector Linac, Light Source and Instrumentation. The researches of each divisions are reviewed, and the users' short reports are collected. The list of published papers with author index is also included in the publication. (K.I.) 233 refs

  20. Math for the digital factory

    CERN Document Server

    Hömberg, Dietmar; Landry, Chantal

    2017-01-01

    This volume provides a unique collection of mathematical tools and industrial case studies in digital manufacturing. It addresses various topics, ranging from models of single production technologies, production lines, logistics and workflows to models and optimization strategies for energy consumption in production. The digital factory represents a network of digital models and simulation and 3D visualization methods for the holistic planning, realization, control and ongoing improvement of all factory processes related to a specific product. In the past ten years, all industrialized countries have launched initiatives to realize this vision, sometimes also referred to as Industry 4.0 (in Europe) or Smart Manufacturing (in the United States). Its main goals are • reconfigurable, adaptive and evolving factories capable of small-scale production • high-performance production, combining flexibility, productivity, precision and zero defects • energy and resource efficiency in manufacturing None of these...

  1. Conversion of an Alpha CAM Monitor of Victoreen calibrated of factory for plutonium in a measurement monitor of radon in the atmosphere

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2004-01-01

    It is presented in this work the conversion of a monitor ALPHA CAM of the monitor Victoreen gauged of it manufactures for plutonium in a monitor for radon mensuration in the atmosphere. Those units in that the radon measures are expressed are: peak curies/unit of volume of air to sampling. This way one has to gauge and to supplement the software and the parts that the old one monitor for plutonium. It requires. This task implies: a) To calibrate and to determine the efficiency of the detector of accustomed to state of 1700 mm 2 for alpha particles coming from the radioactive series of the radon. b) to connect in series and to calibrate a flow measurer of air in it lines with the detector. Measures are presented of the ambient air and other places of the the historical area of the city of Puebla obtained with the team Converted ALPHA-CAM. (Author)

  2. Repeated measurements of NT-pro-B-type natriuretic peptide, troponin T or C-reactive protein do not predict future allograft rejection in heart transplant recipients.

    Science.gov (United States)

    Battes, Linda C; Caliskan, Kadir; Rizopoulos, Dimitris; Constantinescu, Alina A; Robertus, Jan L; Akkerhuis, Martijn; Manintveld, Olivier C; Boersma, Eric; Kardys, Isabella

    2015-03-01

    Studies on the prognostic value of serial biomarker assays for future occurrence of allograft rejection (AR) are scarce. We examined whether repeated measurements of NT-pro-B-type natriuretic peptide (NT-proBNP), troponin T (TropT) and C-reactive protein (CRP) predict AR. From 2005 to 2010, 77 consecutive heart transplantation (HTx) recipients were included. The NT-proBNP, TropT, and CRP were measured at 16 ± 4 (mean ± standard deviation) consecutive routine endomyocardial biopsy surveillance visits during the first year of follow-up. Allograft rejection was defined as International Society for Heart and Lung Transplantation (ISHLT) grade 2R or higher at endomyocardial biopsy. Joint modeling was used to assess the association between repeated biomarker measurements and occurrence of future AR. Joint modeling accounts for dependence among repeated observations in individual patients. The mean age of the patients at HTx was 49 ± 9.2 years, and 68% were men. During the first year of follow-up, 1,136 biopsies and concurrent blood samples were obtained, and 56 patients (73%) experienced at least one episode of AR. All biomarkers were elevated directly after HTx and achieved steady-state after ∼ 12 weeks, both in patients with or without AR. No associations were present between the repeated measurements of NT-proBNP, TropT, or CRP and AR both early (weeks 0-12) and late (weeks 13-52) in the course after HTx (hazard ratios for weeks 13-52: 0.96 (95% confidence interval, 0.55-1.68), 0.67 (0.27-1.69), and 1.44 (0.90-2.30), respectively, per ln[unit]). Combining the three biomarkers in one model also rendered null results. The temporal evolution of NT-proBNP, TropT, and CRP before AR did not predict occurrence of acute AR both in the early and late course of the first year after HTx.

  3. A tau-charm-factory at Argonne

    International Nuclear Information System (INIS)

    Norem, J.; Repond, J.

    1994-01-01

    In this paper we explore the possibility of building a tau-charm-factory at the Argonne National Laboratory. A tau-charm-factory is an e + e - collider with a center-of-mass energy between 3.0 GeV and 5.0 GeV and a luminosity of at least 1 x 10 33 cm -2 s -1 . Once operational, the facility will produce large samples of τ pairs, charm mesons, and charmonium with either negligible or well understood backgrounds. This will lead to high precision measurements in the second generation quark and the third generation lepton sectors that cannot be done at other facilities. Basic physical properties and processes, such as the tau neutrino mass, rare tau decays, charm decay constants, rare charm meson decays, neutral D 0 -- meson mixing, and many more will be studied with unique precision. An initial design of the collider including the injector system is described. The design shows that a luminosity of at least 1 x 10 33 cm -2 s -1 can be achieved over the entire center-of-mass energy range of the factory

  4. Factorial complexity and Morally Debatable Behaviors

    Directory of Open Access Journals (Sweden)

    Grimaldo Muchotrigo, Mirian P.

    2011-12-01

    Full Text Available Currently, from the scientific and professional practice point of view, comes out the necessity to know more about moral permissiveness, as it seems to be an increase in “moral relativism”.. Because it, it this is important to have tools to collect valid and reliable information about moral in social situations defined as social and personal behavior issue. This paper presents a technical note of The Morally Debatable Behaviors Scale (MDBS from Harding & Phillips (1986, which was developed in USA and mainly focused on young people and adults. This technical note makes direct reference to a recent Latin American study (Merino & Grimaldo, 2010; this article focuses on the internal structure and the problems associated with evidences of factorial complexity among items of the MDBS. This means that the interpretation of scores is not factorially simple and could not be achieved by a conceptual distinction between the latent constructs applied to the study sample.. The results in the previous study of the factorial complexity leads the researcher to decide whether an instrument for measuring this aspect may contain a reasonable amount of complexity that is consistent with what is in reality, or look for the unidimensional and simple structure.

  5. Discontinuous Patterns of Cigarette Smoking From Ages 18 to 50 in the United States: A Repeated-Measures Latent Class Analysis.

    Science.gov (United States)

    Terry-McElrath, Yvonne M; O'Malley, Patrick M; Johnston, Lloyd D

    2017-12-13

    Effective cigarette smoking prevention and intervention programming is enhanced by accurate understanding of developmental smoking pathways across the life span. This study investigated within-person patterns of cigarette smoking from ages 18 to 50 among a US national sample of high school graduates, focusing on identifying ages of particular importance for smoking involvement change. Using data from approximately 15,000 individuals participating in the longitudinal Monitoring the Future study, trichotomous measures of past 30-day smoking obtained at 11 time points were modeled using repeated-measures latent class analyses. Sex differences in latent class structure and membership were examined. Twelve latent classes were identified: three characterized by consistent smoking patterns across age (no smoking; smoking developing effective smoking prevention and intervention programming. This study examined cigarette smoking among a national longitudinal US sample of high school graduates from ages 18 to 50 and identified distinct latent classes characterized by patterns of movement between no cigarette use, light-to-moderate smoking, and the conventional definition of heavy smoking at 11 time points via repeated-measures latent class analysis. Membership probabilities for each smoking class were estimated, and critical ages of susceptibility to change in smoking behaviors were identified. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    Science.gov (United States)

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  7. Evaluation of the Gratitude Questionnaire in a Chinese Sample of Adults: Factorial Validity, Criterion-Related Validity, and Measurement Invariance Across Sex.

    Science.gov (United States)

    Kong, Feng; You, Xuqun; Zhao, Jingjing

    2017-01-01

    The Gratitude Questionnaire (GQ; McCullough et al., 2002) is one of the most widely used instruments to assess dispositional gratitude. The purpose of this study was to validate a Chinese version of the GQ by examining internal consistency, factor structure, convergent validity, and measurement invariance across sex. A total of 1151 Chinese adults were recruited to complete the GQ, Positive Affect and Negative Affect Scales, and Satisfaction with Life Scale. Confirmatory factor analysis indicated that the original unidimensional model fitted well, which is in accordance with the findings in Western populations. Furthermore, the GQ had satisfactory composite reliability and criterion-related validity with measures of life satisfaction and affective well-being. Evidence of configural, metric and scalar invariance across sex was obtained. Tests of the latent mean differences found females had higher latent mean scores than males. These findings suggest that the Chinese version of GQ is a reliable and valid tool for measuring dispositional gratitude and can generally be utilized across sex in the Chinese context.

  8. A short German Physical-Self-Concept Questionnaire for elementary school children (PSCQ-C): Factorial validity and measurement invariance across gender.

    Science.gov (United States)

    Lohbeck, Annette; Tietjens, Maike; Bund, Andreas

    2017-09-01

    Research on children's physical self-concept (PSC) is increasingly recognised as an important field of psychology. However, there is a lack of instruments suitable for younger children at elementary school age. In the present study, a short German 21-item Physical Self-Concept-Questionnaire for children (PSCQ-C) was tested measuring seven specific facets of elementary school children's PSC (strength, endurance, speed, flexibility, coordination, physical appearance, global sport competence). A number of 770 elementary school children aged 8-12 years completed the PSCQ-C. Results showed good psychometric properties and high reliabilities of the seven scales. Confirmatory factor analysis revealed that the presumed 7-factor model fitted the data best compared to a global 1- and 2-factor model. Also, full measurement invariance was strongly established. Correlations among the seven scales were mainly moderate. Gender differences were suggestive of developmental trends that are consistent with prior studies. These results provide support that the PSCQ-C is a confidential instrument with sound psychometric properties measuring seven specific facets of elementary school children's PSC.

  9. Repeatability and reproducibility of in situ measurements of sound reflection and airborne sound insulation index of noise barriers

    NARCIS (Netherlands)

    Garai, M.; Schoen, E.; Behler, G.; Bragado, B.; Chudalla, M.; Conter, M.; Defrance, J.; Demizieux, P.; Glorieux, C.; Guidorzi, P.

    2014-01-01

    In Europe, in situ measurements of sound reflection and airborne sound insulation of noise barriers are usually done according to CEN/TS 1793-5. This method has been improved substantially during the EU funded QUIESST collaborative project. Within the same framework, an inter-laboratory test has

  10. New technologies, new hazards: Need for evidence base: A report on the health status and safety measures in a biotechnology factory in Bangalore

    Directory of Open Access Journals (Sweden)

    Sudhashree V

    2007-01-01

    Full Text Available Background: In highly competitive economies, the fast-paced development of new and improved products and services inevitably spurs the development of new technologies, of which one-fifth growth has been in the biotechnology sector. Advances in technologies provide opportunities to minimize the drudgery of work and to eliminate old hazards, but they may create new currently unrecognized risks to workers. Objectives: To assess the morbidity pattern among workers in the biotechnology industry and also to find out the health and safety measures provided to the workers. Materials and Methods: A cross-sectional study was conducted in a biotechnology industry in Bangalore, which covered 779 employees who underwent health examination and blood and urine investigations; of the 779 employees, 600 were permanent employees and 179 were contract employees. Results and Discussion: The common morbidity among the workers included refractory errors; allergic contact dermatitis; hypertension; abnormal pulmonary function tests (61, 10.2%, of which 23 (37.7% were from the production department; high eosinophil count (110, 14.1%. Majority, i.e., 46 (41.8% worked in the production department. The safety measures provided to the workers are adequate, but there is a need to insist on regular use of personal protective devices by newly employed and contract laborers.

  11. Dynamic Pain Phenotypes are Associated with Spinal Cord Stimulation-Induced Reduction in Pain: A Repeated Measures Observational Pilot Study.

    Science.gov (United States)

    Campbell, Claudia M; Buenaver, Luis F; Raja, Srinivasa N; Kiley, Kasey B; Swedberg, Lauren J; Wacnik, Paul W; Cohen, Steven P; Erdek, Michael A; Williams, Kayode A; Christo, Paul J

    2015-07-01

    Spinal cord stimulation (SCS) has become a widely used treatment option for a variety of pain conditions. Substantial variability exists in the degree of benefit obtained from SCS and patient selection is a topic of expanding interest and importance. However, few studies have examined the potential benefits of dynamic quantitative sensory testing (QST) to develop objective measures of SCS outcomes or as a predictive tool to help patient selection. Psychological characteristics have been shown to play an important role in shaping individual differences in the pain experience and may aid in predicting responses to SCS. Static laboratory pain-induction measures have also been examined in their capacity for predicting SCS outcomes. The current study evaluated clinical, psychological and laboratory pain measures at baseline, during trial SCS lead placement, as well as 1 month and 3 months following permanent SCS implantation in chronic pain patients who received SCS treatment. Several QST measures were conducted, with specific focus on examination of dynamic models (central sensitization and conditioned pain modulation [CPM]) and their association with pain outcomes 3 months post SCS implantation. Results suggest few changes in QST over time. However, central sensitization and CPM at baseline were significantly associated with clinical pain at 3 months following SCS implantation, controlling for psycho/behavioral factors and pain at baseline. Specifically, enhanced central sensitization and reduced CPM were associated with less self-reported pain 3 months following SCS implantation. These findings suggest a potentially important role for dynamic pain assessment in individuals undergoing SCS, and hint at potential mechanisms through which SCS may impart its benefit. Wiley Periodicals, Inc.

  12. Neutrino factory plans at CERN

    CERN Document Server

    Riche, J A

    2001-01-01

    The considerable interest raised by the discovery of neutrino oscillations and recent progress in studies of muon colliders has triggered interest in considering a neutrino factory at CERN. This paper explains the reference scenario, indicates the other possible choices and mentions the R&D that are foreseen.

  13. Planned e+e- factories

    International Nuclear Information System (INIS)

    Le Duff, J.

    1993-09-01

    Various Beauty and Tau-Charm factories and projects are reviewed. Different machines (TRISTAN II, PEP II, CESR-B, the Dubna project and the European project) are compared and their design and parameters are described. (K.A.) 34 refs., 2 figs., 2 tabs

  14. Factorial representations of path groups

    International Nuclear Information System (INIS)

    Albeverio, S.; Hoegh-Krohn, R.; Testard, D.; Vershik, A.

    1983-11-01

    We give the reduction of the energy representation of the group of mappings from I = [ 0,1 ], S 1 , IRsub(+) or IR into a compact semi simple Lie group G. For G = SU(2) we prove the factoriality of the representation, which is of type III in the case I = IR

  15. A Review of "Infinity Factory."

    Science.gov (United States)

    National Council of Teachers of Mathematics, Inc., Reston, VA.

    Following a discussion of the historical background of the TV series "Infinity Factory," the goals of the television project are listed. A general description of the television series, an evaluation of the entertainment value, and an evaluation of children's attitude change are briefly presented. The program's presentation of mathematics…

  16. Reappraisal of serum insulin-like growth factor-I (IGF-1) measurement in the detection of isolated and combined growth hormone deficiency (GHD) during the transition period.

    Science.gov (United States)

    Boguszewski, Cesar L; Lacerda, Claudio Silva de; Lacerda Filho, Luiz de; Carvalho, Julienne A R de; Boguszewski, Margaret C S

    2013-12-01

    To evaluate the accuracy of serum IGF-1 in the detection of isolated (IGHD) or combined growth hormone deficiency (CGHD) at the transition phase. Forty nine patients with GHD during childhood [16 with IGHD (10 men) and 33 with CGHD (24 men); age 23.2 ± 3.5 yrs.] were submitted to an insulin tolerance test (ITT) with a GH peak IGF-1 measurements were evaluated in the basal sample of the ITT. Transition patients were reclassified as GH-sufficient (SGH; n = 12), IGHD (n = 7), or CGHD (n = 30). Five (31%) patients with IGHD and 32 (97%) with CGHD at childhood persisted with GHD at retesting. One patient with IGHD was reclassified as CGHD, whereas 3 patients with CGHD were reclassified as IGHD. Mean GH peak was 0.2 ± 0.3 µg/L in the CGHD, 1.3 ± 1.5 µg/L in the IGHD, and 18.1 ± 13.1 µg/L in the SGH group. Serum IGF-1 level was significantly higher in the SGH (272 ± 107 ng/mL) compared to IGHD (100.2 ± 110) and CGHD (48.7 ± 32.8) (p IGF-1 level, resulting in 97.3% sensitivity and 91.6% specificity in the detection of GHD at the transition period; the cutoff value of 110 ng/mL showed 94.5% sensitivity and 100% specificity. Mean IGF-1 values did not differ in IGHD or CGHD associated with one, two, three, or four additional pituitary deficiencies. IGF-1 measurement is accurate to replace ITT as initial diagnostic test for IGHD and CGHD detection at the transition phase.

  17. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between......, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity....

  18. Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study

    Directory of Open Access Journals (Sweden)

    Hinderliter Alan L

    2011-04-01

    Full Text Available Abstract Background Ambulatory blood pressure monitoring (ABPM is increasingly used to measure blood pressure (BP in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting. Methods Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions, we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements. Results The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2. Wearers found the monitor straightforward to use (mean 7.5. Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%, skin irritation (37%, and bruising (7%. Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003 were more likely to report being in fair/poor health (75% vs 22%, p = 0.01 and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37. They were

  19. Análise factorial confirmatória do TEOSQp Confirmatory factorial analysis of TEOSQp

    Directory of Open Access Journals (Sweden)

    Helder M. Fernandes

    2010-04-01

    Full Text Available O propósito do presente estudo foi avaliar a confiabilidade, a validade factorial e a invariância (por sexo da versão portuguesa do TEOSQ (Fonseca & Biddle, 2001. Integraram a amostra 1010 estudantes com uma média de idade de 15,42 anos. A análise factorial e da invariância foi avaliada através da análise factorial confirmatória. Os resultados corroboram a proposta de uma estrutura de duas subescalas (tarefa e ego. Com base nos índices de modificação e justificação teórica, o TEOSQ p foi reduzido a 12-itens, com melhores índices de adequação para o modelo oblíquo. Os resultados relativos à invariância por sexo não apresentaram apoio empírico total para a assumpção de equivalência multi-grupo, sugerindo que o TEOSQ p não parece avaliar as orientações cognitivas do mesmo modo, para os indivíduos do sexo masculino (modelo ortogonal e feminino (modelo oblíquo. Face aos resultados obtidos, foram discutidas as implicações conceptuais, empíricas, assim como os aspectos de carácter aplicado.The present research assessed the reliability, factorial validity and measurement invariance (by gender of the Portuguese version of TEOSQ -Task and Ego Orientation in Sport Questionnaire (Fonseca & Biddle, 2001. Data were collected from 1010 physical education students with a mean age of 15.42 ( SD=1.91. Factorial and invariance measurements were tested via confirmatory factorial analysis. Results supported internal consistency for the two proposed subscales (task and ego. Based on modification indices and theoretical justification the TEOSQ p was reduced to 12 items with better goodness-of-fit indices for the oblique model. The results of gender invariance did not provide full empirical support to the multi-group equivalence assumption, being suggested that TEOSQ p does not measure in the same way goal orientations for boys (orthogonal model and girls (oblique model. In light of these results, conceptual, empirical and practical

  20. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  1. Photon Factory Activity Report, 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    Photon Factory Activity Report no.12 deals with our activities in the period from October 1993 through September 1994. We operate two light sources at the Photon Factory; the 2.5-GeV Photon Factory storage ring, which is a dedicated light source, and the 6.5-GeV TRISTAN Accumulation Ring, which is parasitically used as a light source. We keep more than seventy experimental stations at two facilities, and accept experiments primarily according to approval by the Program Advisory Committee. The number of proposals to the Photon Factory has been still growing. Three-hundred eighty two proposals were approved by the PAC in FY1994, which is an increase by thirteen percent compared to the previous year. Remarkable was growth in biology proposals, particularly proposals in protein crystallography. In FY 1994, we accepted approximately 20,000 man-days as general users, and almost ten percent of them were from abroad. We always open the facility to users, not only domestic but also international. Recently we have been concentrating our effort to upgrading of the light sources and reconstruction of the experimental stations to keep the Photon Factory an attractive research facility in the forthcoming years. We have already started a program of reducing the emittance of the 2.5-GeV storage ring, which now operates with an emittance of 110 nm-rad, to 27 nm-rad by modifying the lattice, with the goal of operation at the reduced emittance in the fall of 1997. We also have conceived of a conversion of the TRISTAN Accumulation Ring to a dedicated light source of high energies. The on-going TRISTAN project will terminate by the end of 1995, and the TRISTAN Main Ring will be converted to a new B-Factory. At this moment, the TRISTAN Accumulation Ring will be disused as the injector to the Main Ring, and conversion of the AR to a dedicated light source becomes possible. (J.P.N.)

  2. Photon Factory Activity Report, 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    Photon Factory Activity Report no.12 deals with our activities in the period from October 1993 through September 1994. We operate two light sources at the Photon Factory; the 2.5-GeV Photon Factory storage ring, which is a dedicated light source, and the 6.5-GeV TRISTAN Accumulation Ring, which is parasitically used as a light source. We keep more than seventy experimental stations at two facilities, and accept experiments primarily according to approval by the Program Advisory Committee. The number of proposals to the Photon Factory has been still growing. Three-hundred eighty two proposals were approved by the PAC in FY1994, which is an increase by thirteen percent compared to the previous year. Remarkable was growth in biology proposals, particularly proposals in protein crystallography. In FY 1994, we accepted approximately 20,000 man-days as general users, and almost ten percent of them were from abroad. We always open the facility to users, not only domestic but also international. Recently we have been concentrating our effort to upgrading of the light sources and reconstruction of the experimental stations to keep the Photon Factory an attractive research facility in the forthcoming years. We have already started a program of reducing the emittance of the 2.5-GeV storage ring, which now operates with an emittance of 110 nm-rad, to 27 nm-rad by modifying the lattice, with the goal of operation at the reduced emittance in the fall of 1997. We also have conceived of a conversion of the TRISTAN Accumulation Ring to a dedicated light source of high energies. The on-going TRISTAN project will terminate by the end of 1995, and the TRISTAN Main Ring will be converted to a new B-Factory. At this moment, the TRISTAN Accumulation Ring will be disused as the injector to the Main Ring, and conversion of the AR to a dedicated light source becomes possible. (J.P.N.)

  3. Photon Factory Activity Report, 1994

    International Nuclear Information System (INIS)

    1995-01-01

    Photon Factory Activity Report no.12 deals with our activities in the period from October 1993 through September 1994. We operate two light sources at the Photon Factory; the 2.5-GeV Photon Factory storage ring, which is a dedicated light source, and the 6.5-GeV TRISTAN Accumulation Ring, which is parasitically used as a light source. We keep more than seventy experimental stations at two facilities, and accept experiments primarily according to approval by the Program Advisory Committee. The number of proposals to the Photon Factory has been still growing. Three-hundred eighty two proposals were approved by the PAC in FY1994, which is an increase by thirteen percent compared to the previous year. Remarkable was growth in biology proposals, particularly proposals in protein crystallography. In FY 1994, we accepted approximately 20,000 man-days as general users, and almost ten percent of them were from abroad. We always open the facility to users, not only domestic but also international. Recently we have been concentrating our effort to upgrading of the light sources and reconstruction of the experimental stations to keep the Photon Factory an attractive research facility in the forthcoming years. We have already started a program of reducing the emittance of the 2.5-GeV storage ring, which now operates with an emittance of 110 nm-rad, to 27 nm-rad by modifying the lattice, with the goal of operation at the reduced emittance in the fall of 1997. We also have conceived of a conversion of the TRISTAN Accumulation Ring to a dedicated light source of high energies. The on-going TRISTAN project will terminate by the end of 1995, and the TRISTAN Main Ring will be converted to a new B-Factory. At this moment, the TRISTAN Accumulation Ring will be disused as the injector to the Main Ring, and conversion of the AR to a dedicated light source becomes possible. (J.P.N.)

  4. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  5. Rare B decays at B factories

    International Nuclear Information System (INIS)

    Trabelsi, Karim

    2010-01-01

    Radiative and Electroweak Penguin Decays are Flavor Changing Neutral Currents (FCNC) occurring in the Standard Model only at the loop level. They are characterized by high sensitivity to New Physics (they can appear in the loop with size comparable to leading SM contributions) and they are Complementary to the direct production of new particles expected at LHC. Huge datasets collected at the two B- factories, BaBar and Belle, have made it possible to explore precisely these decays in exclusive channels and inclusive measurements. b →sγ, b→dγ, b→s l + l - , B + →τν, B→Dτν etc measured provide tests of SM predictions and interesting BSM constraints: Charged Higgs bounds from b →sγ, B + →τν, B + →Dτν; Constraints on Wilson coefficients C 7 , C 9 and C 10 ; and Constraints on |V td |/|V ts |. They provide interesting signatures: B(B + →τ + ν) direct measurement versus CKM fit; and large forward-backward asymmetry of K* l + l - . Final Belle/BaBar data samples are yet to be analyzed and even more interesting results are expected at Super B factories with two orders of magnitude larger data samples

  6. Handbook factory planning and design

    CERN Document Server

    Wiendahl, Hans-Peter; Nyhuis, Peter

    2015-01-01

    This handbook introduces a methodical approach and pragmatic concept for the planning and design of changeable factories that act in strategic alliances to supply the ever-changing needs of the global market. In the first part, the change drivers of manufacturing enterprises and the resulting new challenges are considered in detail with focus on an appropriate change potential. The second part concerns the design of the production facilities and systems on the factory levels work place, section, building and site under functional, organisational, architectural and strategic aspects keeping in mind the environmental, health and safety aspects including corporate social responsibility. The third part is dedicated to the planning and design method that is based on a synergetic interaction of process and space. The accompanying project management of the planning and construction phase and the facility management for the effective utilization of the built premises close the book. -        Concise overview o...

  7. RIKEN RI Beam Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Yasushige; Goto, Akira; Katayama, Takeshi [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1997-03-01

    The RARF proposes `RIKEN RI Beam Factory` as a next facility-expanding project. The factory makes it the primary aim to provide RI (Radioactive Isotope) beams covering over the whole atomic-mass range with the world-highest intensity in a wide energy range up to several hundreds MeV/nucleon. These RI beams are generated by the fragmentation of high-intensity heavy-ion beams. For the efficient production heavy-ion energies will be boosted up to over 100 MeV/nucleon even for very heavy ions by a K2500-MeV superconducting ring cyclotron serving as a post accelerator of the existing K540-MeV ring cyclotron. A new type of experimental installation called `MUSES` (Multi-USe Experimental Storage rings) will be constructed as well. With MUSES, various types of unique colliding experiments will become possible. (author)

  8. On KEK B-Factory

    Science.gov (United States)

    Sugawara, H.

    2009-07-01

    There are two principles which the management of a research institute like KEK must respect when dealing with such big project as B-Factory. One is the scientific merit of the project and the other is the organizational consideration which includes financial, human, technical and historical elements. Ideally, the two principles are to be fully taken into account. But, in many cases, one or the other is only partially fulfilled due to unavoidable circumstances. The lack of flexibility to respond to all possible situations is more dangerous and may lead to a disaster as in the case of SSC. I will describe the process which lead to the successful construction, operation and physics presentations of KEK B-Factory following faithfully the official records.

  9. On KEK B-factory

    International Nuclear Information System (INIS)

    Sugawara, Hirotaka

    2009-01-01

    There are two principles which the management of a research institute like KEK must respect when dealing with such big project as B-Factory. One is the scientific merit of the project and the other is the organizational consideration which includes financial, human, technical and historical elements. Ideally, the two principles are to be fully taken into account. But, in many cases, one or the other is only partially fulfilled due to unavoidable circumstances. The lack of flexibility to respond to all possible situations is more dangerous and may lead to a disaster as in the case of SSC. I will describe the process which lead to the successful construction, operation and physics presentations of KEK B-Factory following faithfully the official records. (author)

  10. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  11. Experimental evaluation of rigor mortis. VIII. Estimation of time since death by repeated measurements of the intensity of rigor mortis on rats.

    Science.gov (United States)

    Krompecher, T

    1994-10-21

    The development of the intensity of rigor mortis was monitored in nine groups of rats. The measurements were initiated after 2, 4, 5, 6, 8, 12, 15, 24, and 48 h post mortem (p.m.) and lasted 5-9 h, which ideally should correspond to the usual procedure after the discovery of a corpse. The experiments were carried out at an ambient temperature of 24 degrees C. Measurements initiated early after death resulted in curves with a rising portion, a plateau, and a descending slope. Delaying the initial measurement translated into shorter rising portions, and curves initiated 8 h p.m. or later are comprised of a plateau and/or a downward slope only. Three different phases were observed suggesting simple rules that can help estimate the time since death: (1) if an increase in intensity was found, the initial measurements were conducted not later than 5 h p.m.; (2) if only a decrease in intensity was observed, the initial measurements were conducted not earlier than 7 h p.m.; and (3) at 24 h p.m., the resolution is complete, and no further changes in intensity should occur. Our results clearly demonstrate that repeated measurements of the intensity of rigor mortis allow a more accurate estimation of the time since death of the experimental animals than the single measurement method used earlier. A critical review of the literature on the estimation of time since death on the basis of objective measurements of the intensity of rigor mortis is also presented.

  12. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  13. Apiary B Factory lattice design

    International Nuclear Information System (INIS)

    Donald, M.H.R.; Garren, A.A.

    1991-04-01

    The Apiary B Factory is a proposed high-intensity electron-positron collider. This paper will present the lattice design for this facility, which envisions two rings with unequal energies in the PEP tunnel. The design has many interesting optical and geometrical features due to the needs to conform to the existing tunnel, and to achieve the necessary emittances, damping times and vacuum. Existing hardware is used to a maximum extent. 8 figs. 1 tab

  14. A kaon factory for TRIUMF

    International Nuclear Information System (INIS)

    Measday, D.F.

    1988-11-01

    The design study for the TRIUMF Kaon Factory has recently been funded. A short discussion of the scientific motivation is given first, followed by a brief description of the 30 GeV synchrotron which is being proposed. There will be five rings altogether using the present TRIUMF 500 MeV cyclotron as an injector. If the project is funded in 1990 the accelerators would be completed in 1995 or so, and the experimental programme would start a year later

  15. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2018-01-01

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. Evidence of radiation-induced reduction of height and body weight from repeated measurements of adults exposed in childhood to the atomic bombs

    International Nuclear Information System (INIS)

    Otake, Masanori; Funamoto, Sachiyo; Fujikoshi, Yasunori; Schull, W.J.

    1994-01-01

    Reduction of growth from exposure to atomic bomb radiation has been examined using individuals under 10 years old at the time of the bombing (ATB) and a growth curve analysis based on measurements of height and weight made in the course of the 4th-7th cycles of the Adult Health Study examinations (1964-1972). As expected, the largest difference in growth to emerge is between males and females. However, a highly significant reduction of growth associated with dose (DS86) was observed among those survivors for whom four repeated measurements of height and weight were available. Longitudinal analysis of a more extended data set (n = 821), using expected values based on simple linear regression models fitted to the three available sets of measurements of height and weight on the 254 individuals with a missing measurement, also indicates a significant radiation-related growth reduction. The possible contribution of such factors as poor nutrition and disruption of normal family life in the years immediately after the war is difficult to evaluate, but the effects of socioeconomic factors on the analysis of these data are discussed. 33 refs., 5 figs., 3 tabs

  17. Photon Factory activity report, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    The Photon Factory at the National Laboratory for High Energy Physics is a national facility for scientific research utilizing synchrotron radiation. Although the Photon Factory operator the linear injector, two light sources including the 2.5 GeV storage ring and the 6.5 GeV TRISTAN accumulation Ring as well as a major fraction of their beamlines and experimental station. This report is covered the period from October 1994 to September 1995. The total number of proposals by this PAC was 399 in 1995. Facility development projects currently in progress include the following, TRISTAN Super Light Facility (TSLF) project, VUV-FEL project, KEKB project and Slow-positron Source. This report contents outline of the Photon Factory, introduction, scientific disciplines, electronic properties of condensed matters, atomic and molecular science, X-ray imaging, radiobiology using synchrotron radiation, structural properties of condensed matters, structural properties of solid surfaces and adsorbates, structure and function of proteins, theoretical researches, experimental facilities, beamlines, new instrumentation, AR Upgrade, collaborations, projects, user`s short reports, list of published papers 1994/95. (S.Y.)

  18. Photon Factory activity report, 1995

    International Nuclear Information System (INIS)

    1996-01-01

    The Photon Factory at the National Laboratory for High Energy Physics is a national facility for scientific research utilizing synchrotron radiation. Although the Photon Factory operator the linear injector, two light sources including the 2.5 GeV storage ring and the 6.5 GeV TRISTAN accumulation Ring as well as a major fraction of their beamlines and experimental station. This report is covered the period from October 1994 to September 1995. The total number of proposals by this PAC was 399 in 1995. Facility development projects currently in progress include the following, TRISTAN Super Light Facility (TSLF) project, VUV-FEL project, KEKB project and Slow-positron Source. This report contents outline of the Photon Factory, introduction, scientific disciplines, electronic properties of condensed matters, atomic and molecular science, X-ray imaging, radiobiology using synchrotron radiation, structural properties of condensed matters, structural properties of solid surfaces and adsorbates, structure and function of proteins, theoretical researches, experimental facilities, beamlines, new instrumentation, AR Upgrade, collaborations, projects, user's short reports, list of published papers 1994/95. (S.Y.)

  19. Photon Factory activity report, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The Photon Factory at the National Laboratory for High Energy Physics is a national facility for scientific research utilizing synchrotron radiation. Although the Photon Factory operator the linear injector, two light sources including the 2.5 GeV storage ring and the 6.5 GeV TRISTAN accumulation Ring as well as a major fraction of their beamlines and experimental station. This report is covered the period from October 1994 to September 1995. The total number of proposals by this PAC was 399 in 1995. Facility development projects currently in progress include the following, TRISTAN Super Light Facility (TSLF) project, VUV-FEL project, KEKB project and Slow-positron Source. This report contents outline of the Photon Factory, introduction, scientific disciplines, electronic properties of condensed matters, atomic and molecular science, X-ray imaging, radiobiology using synchrotron radiation, structural properties of condensed matters, structural properties of solid surfaces and adsorbates, structure and function of proteins, theoretical researches, experimental facilities, beamlines, new instrumentation, AR Upgrade, collaborations, projects, user`s short reports, list of published papers 1994/95. (S.Y.)

  20. Outbreak of Occupational Brucellosis at a Pharmaceutical Factory in Southeast China.

    Science.gov (United States)

    Zhan, B D; Wang, S Q; Lai, S M; Lu, Y; Shi, X G; Cao, G P; Hu, X L; Zheng, C J; Yu, Z Y; Zhang, J M; Fang, C F; Gong, Z Y

    2017-09-01

    Brucellosis is an occupational disease affecting workers in butcher shops, the milking and dairy product industry, causing more than 500 000 new cases around the world. As a national statutory B infectious disease in China, morbidity of brucellosis is rapidly increasing in recent years. We report an occupational outbreak of brucellosis infection in a pharmaceutical factory. Exposure was a result of manual operation in the process line, close contact with sheep placentas, insufficient disinfection and repeated using of protective suits and infected by aerosol dissemination. Improved preventive methods, appropriate public health measures and spread of health education would be helpful to prevent the occupational outbreak of brucellosis in future. © 2016 Blackwell Verlag GmbH.

  1. R and D Toward Neutrino Factories and Muon Colliders

    International Nuclear Information System (INIS)

    Zisman, Michael S.

    2003-01-01

    R and D aimed at the production, acceleration, and storage of intense muon beams is under way in the U.S., in Europe, and in Japan. Considerable progress has been made in the past few years toward the design of a ''Neutrino Factory'' in which a beam of 20-50 GeV mu- or mu+ is stored. Decay neutrinos from the beam illuminate a detector located roughly 3000 km from the ring. Here, we briefly describe the ingredients of a Neutrino Factory and then discuss the current R and D program and its results. A key concept in the design is ''ionization cooling,'' a process whereby the muon emittance is reduced by repeated interactions with an absorber material followed by reacceleration with high-gradient rf cavities. Plans to test this concept in the Muon Ionization Cooling Experiment (MICE) are well along and are described briefly

  2. Profil Konsumen dan Pesaing pada “Factory Bakery”

    OpenAIRE

    Salam, Ramdhan; Rengkung, Leonardus R; Katiandagho, Theodora M; Ngangi, Charles R

    2015-01-01

    The purpose of this study was to describe the profile of competitors and consumers in the Factory Bakery. This research was conducted at the Factory Bakery is located at Pogidon Street, Tuminting, Manado. The collection of data carried out for three months, from June 2015 to Agustus 2015. The primary data in this study were taken two ways to measure the variables of consumers by asking directly to consumers for six days, whereas for measuring competitors by asking directly to the owner of th...

  3. Repeated tumor pO2 measurements by multi-site EPR oximetry as a prognostic marker for enhanced therapeutic efficacy of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Hou Huagang; Lariviere, Jean P.; Demidenko, Eugene; Gladstone, David; Swartz, Harold; Khan, Nadeem

    2009-01-01

    Purpose: To investigate the temporal effects of single or fractionated radiotherapy on subcutaneous RIF-1 tumor pO 2 and to determine the therapeutic outcomes when the timing of fractionations is guided by tumor pO 2 . Methods: The time-course of the tumor pO 2 changes was followed by multi-site electron paramagnetic resonance (EPR) oximetry. The tumors were treated with single 10, 20, and 10 Gy x 2 doses, and the tumor pO 2 was measured repeatedly for six consecutive days. In the 10 Gy x 2 group, the second dose of 10 Gy was delivered at a time when the tumors were either relatively oxygenated or hypoxic. The changes in tumor volumes were followed for nine days to determine the therapeutic outcomes. Results: A significant increase in tumor pO 2 was observed at 24 h post 10 Gy, while 20 Gy resulted in a significant increase in tumor pO 2 at 72-120 h post irradiation. The tumors irradiated with a second dose of 10 Gy at 24 h, when the tumors were oxygenated, had a significant increase in tumor doubling times (DTs), as compared to tumors treated at 48 h when they were hypoxic (p 2 repeatedly during fractionated schemes to optimize radiotherapeutic outcome. This technique could also be used to identify responsive and non-responsive tumors, which will facilitate the design of other therapeutic approaches for non-responsive tumors at early time points during the course of therapy.

  4. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  5. Repeat, Low Altitude Measurements of Vegetation Status and Biomass Using Manned Aerial and UAS Imagery in a Piñon-Juniper Woodland

    Science.gov (United States)

    Krofcheck, D. J.; Lippitt, C.; Loerch, A.; Litvak, M. E.

    2015-12-01

    Measuring the above ground biomass of vegetation is a critical component of any ecological monitoring campaign. Traditionally, biomass of vegetation was measured with allometric-based approach. However, it is also time-consuming, labor-intensive, and extremely expensive to conduct over large scales and consequently is cost-prohibitive at the landscape scale. Furthermore, in semi-arid ecosystems characterized by vegetation with inconsistent growth morphologies (e.g., piñon-juniper woodlands), even ground-based conventional allometric approaches are often challenging to execute consistently across individuals and through time, increasing the difficulty of the required measurements and consequently the accuracy of the resulting products. To constrain the uncertainty associated with these campaigns, and to expand the extent of our measurement capability, we made repeat measurements of vegetation biomass in a semi-arid piñon-juniper woodland using structure-from-motion (SfM) techniques. We used high-spatial resolution overlapping aerial images and high-accuracy ground control points collected from both manned aircraft and multi-rotor UAS platforms, to generate digital surface model (DSM) for our experimental region. We extracted high-precision canopy volumes from the DSM and compared these to the vegetation allometric data, s to generate high precision canopy volume models. We used these models to predict the drivers of allometric equations for Pinus edulis and Juniperous monosperma (canopy height, diameter at breast height, and root collar diameter). Using this approach, we successfully accounted for the carbon stocks in standing live and standing dead vegetation across a 9 ha region, which contained 12.6 Mg / ha of standing dead biomass, with good agreement to our field plots. Here we present the initial results from an object oriented workflow which aims to automate the biomass estimation process of tree crown delineation and volume calculation, and partition

  6. Baseline repeated measures from controlled human exposure studies: associations between ambient air pollution exposure and the systemic inflammatory biomarkers IL-6 and fibrinogen.

    Science.gov (United States)

    Thompson, Aaron M S; Zanobetti, Antonella; Silverman, Frances; Schwartz, Joel; Coull, Brent; Urch, Bruce; Speck, Mary; Brook, Jeffrey R; Manno, Michael; Gold, Diane R

    2010-01-01

    Systemic inflammation may be one of the mechanisms mediating the association between ambient air pollution and cardiovascular morbidity and mortality. Interleukin-6 (IL-6) and fibrinogen are biomarkers of systemic inflammation that are independent risk factors for cardio-vascular disease. We investigated the association between ambient air pollution and systemic inflammation using baseline measurements of IL-6 and fibrinogen from controlled human exposure studies. In this retrospective analysis we used repeated-measures data in 45 nonsmoking subjects. Hourly and daily moving averages were calculated for ozone, nitrogen dioxide, sulfur dioxide, and particulate matter pollutants on systemic IL-6 and fibrinogen. Effect modification by season was considered. We observed a positive association between IL-6 and O3 [0.31 SD per O3 interquartile range (IQR); 95% confidence interval (CI), 0.080.54] and between IL-6 and SO2 (0.25 SD per SO2 IQR; 95% CI, 0.060.43). We observed the strongest effects using 4-day moving averages. Responses to pollutants varied by season and tended to be higher in the summer, particularly for O3 and PM2.5. Fibrinogen was not associated with pollution. This study demonstrates a significant association between ambient pollutant levels and baseline levels of systemic IL-6. These findings have potential implications for controlled human exposure studies. Future research should consider whether ambient pollution exposure before chamber exposure modifies IL-6 response.

  7. Information security of Smart Factories

    Science.gov (United States)

    Iureva, R. A.; Andreev, Y. S.; Iuvshin, A. M.; Timko, A. S.

    2018-05-01

    In several years, technologies and systems based on the Internet of things (IoT) will be widely used in all smart factories. When processing a huge array of unstructured data, their filtration and adequate interpretation are a priority for enterprises. In this context, the correct representation of information in a user-friendly form acquires special importance, for which the market today presents advanced analytical platforms designed to collect, store and analyze data on technological processes and events in real time. The main idea of the paper is the statement of the information security problem in IoT and integrity of processed information.

  8. Incense and Joss Stick Making in Small Household Factories, Thailand

    Directory of Open Access Journals (Sweden)

    S Siripanich

    2014-07-01

    Full Text Available Background: Incense and joss stick are generally used in the world. Most products were made in small household factories. There are many environmental and occupational hazards in these factories. Objective: To evaluate the workplace environmental and occupational hazards in small household incense and joss stick factories in Roi-Et, Thailand. Methods: Nine small household factories in rural areas of Roi-Et, Thailand, were studied. Dust concentration and small aerosol particles were counted through real time exposure monitoring. The inductively coupled plasma optical emission spectrometry (ICP-OES was used for quantitative measurement of heavy metal residue in incense products. Results: Several heavy metals were found in dissolved dye and joss sticks. Those included barium, manganese, and lead. Rolling and shaking processes produced the highest concentration of dust and aerosols. Only 3.9 % of female workers used personal protection equipment. Conclusion: Dust and chemicals were major threats in small household incense and joss stick factories in Thailand. Increasing awareness towards using personal protection equipment and emphasis on elimination of environmental workplace hazards should be considered to help the workers of this industry.

  9. Photon Factory activity report, 1988

    International Nuclear Information System (INIS)

    1989-01-01

    Since the foundation of Photon Factory a decade age, it has played an important role as a unique synchrotron X-ray radiation source in Japan. Installation of various insertion devices, storage of intense positron beam and reduction of beam emittance were the substantial achievements in the last several years. The exploitation of the TRISTAN Accumulation Ring as a synchrotron radiation source has paved the way for a new potential of development. All these activities have brought about the increase of beamlines and the expansion of scientific fronts. Third International Conference on Synchrotron Radiation Instrumentation held in Tsukuba was one of the most highlighted events for the facility. In coming years, it is intended to open new research fields using the promising single bunch beam and circularly polarized wiggler radiation. The TRISTAN Main Ring also will be applied to synchrotron radiation research. The Photon Factory in a national synchrotron radiation research facility affiliated to the National Laboratory for High Energy Physics, and it consists of a 2.5 GeV electron linac, a 2.5 GeV storage ring as a synchrotron light source, beam lines and experimental stations. The operation, improvement and development in respective departments are reported. (Kako, I.)

  10. Simple sequence repeat (SSR)-based genetic variability among ...

    African Journals Online (AJOL)

    The objective of this study was to compare if simple sequence repeat (SSR) markers could correctly identify peanut genotypes with difference in specific leaf weight (SLW) and relative water content (RWC). Four peanut genotypes and two water regimes (FC and 1/3 available water; 1/3 AW) were arranged in factorial ...

  11. Usefulness of repeated N-terminal pro-B-type natriuretic peptide measurements as incremental predictor for long-term cardiovascular outcome after vascular surgery.

    Science.gov (United States)

    Goei, Dustin; van Kuijk, Jan-Peter; Flu, Willem-Jan; Hoeks, Sanne E; Chonchol, Michel; Verhagen, Hence J M; Bax, Jeroen J; Poldermans, Don

    2011-02-15

    Plasma N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) levels improve preoperative cardiac risk stratification in vascular surgery patients. However, single preoperative measurements of NT-pro-BNP cannot take into account the hemodynamic stress caused by anesthesia and surgery. Therefore, the aim of the present study was to assess the incremental predictive value of changes in NT-pro-BNP during the perioperative period for long-term cardiac mortality. Detailed cardiac histories, rest left ventricular echocardiography, and NT-pro-BNP levels were obtained in 144 patients before vascular surgery and before discharge. The study end point was the occurrence of cardiovascular death during a median follow-up period of 13 months (interquartile range 5 to 20). Preoperatively, the median NT-pro-BNP level in the study population was 314 pg/ml (interquartile range 136 to 1,351), which increased to a median level of 1,505 pg/ml (interquartile range 404 to 6,453) before discharge. During the follow-up period, 29 patients (20%) died, 27 (93%) from cardiovascular causes. The median difference in NT-pro-BNP in the survivors was 665 pg/ml, compared to 5,336 pg/ml in the patients who died (p = 0.01). Multivariate Cox regression analyses, adjusted for cardiac history and cardiovascular risk factors (age, angina pectoris, myocardial infarction, stroke, diabetes mellitus, renal dysfunction, body mass index, type of surgery and the left ventricular ejection fraction), demonstrated that the difference in NT-pro-BNP level between pre- and postoperative measurement was the strongest independent predictor of cardiac outcome (hazard ratio 3.06, 95% confidence interval 1.36 to 6.91). In conclusion, the change in NT-pro-BNP, indicated by repeated measurements before surgery and before discharge is the strongest predictor of cardiac outcomes in patients who undergo vascular surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Search for new physics at a super-B factory

    Indian Academy of Sciences (India)

    The importance of a super- factory in the search for new physics, in particular, due to CP-odd phase(s) from physics beyond the standard model is surveyed. The first point to emphasize is that we now know how to directly measure all three angles of the unitarity triangle very cleanly, i.e. without theoretical assumptions with ...

  13. Impact of a person-centred dementia care training programme on hospital staff attitudes, role efficacy and perceptions of caring for people with dementia: A repeated measures study.

    Science.gov (United States)

    Surr, C A; Smith, S J; Crossland, J; Robins, J

    2016-01-01

    People with dementia occupy up to one quarter of acute hospital beds. However, the quality of care delivered to this patient group is of national concern. Staff working in acute hospitals report lack of knowledge, skills and confidence in caring for people with dementia. There is limited evidence about the most effective approaches to supporting acute hospital staff to deliver more person-centred care. This study aimed to evaluate the efficacy of a specialist training programme for acute hospital staff regarding improving attitudes, satisfaction and feelings of caring efficacy, in provision of care to people with dementia. A repeated measures design, with measures completed immediately prior to commencing training (T1), after completion of Foundation level training (T2: 4-6 weeks post-baseline), and following Intermediate level training (T3: 3-4 months post-baseline). One NHS Trust in the North of England, UK. 40 acute hospital staff working in clinical roles, the majority of whom (90%) were nurses. All participants received the 3.5 day Person-centred Care Training for Acute Hospitals (PCTAH) programme, comprised of two levels, Foundation (0.5 day) and Intermediate (3 days), delivered over a 3-4 months period. Staff demographics and previous exposure to dementia training were collected via a questionnaire. Staff attitudes were measured using the Approaches to Dementia Questionnaire (ADQ), satisfaction in caring for people with dementia was captured using the Staff Experiences of Working with Demented Residents questionnaire (SEWDR) and perceived caring efficacy was measured using the Caring Efficacy Scale (CES). The training programme was effective in producing a significant positive change on all three outcome measures following intermediate training compared to baseline. A significant positive effect was found on the ADQ between baseline and after completion of Foundation level training, but not for either of the other measures. Training acute hospital staff in

  14. Hearing effects from intermittent and continuous noise exposure in a study of Korean factory workers and firefighters

    Directory of Open Access Journals (Sweden)

    Chung In-Sung

    2012-01-01

    Full Text Available Abstract Background South Korea and surrounding countries in East Asia are believed to have the highest proportion in the world of high frequency hearing loss due to occupational noise exposure, yet there has been limited information published in international journals, and limited information for control of noise in local workplaces beyond strategies from western countries. We exploit medical surveillance information from two worker groups to enhance local knowledge about noise-induced hearing loss and explore the possible importance of shift work to risk. Methods Four-years of hearing data were evaluated for 81 male farm machine factory workers and 371 male firefighters who had successfully completed a health examination and questionnaires for the duration of the study period. The averages of hearing thresholds at 2, 3, and 4 kHz were used as the primary end-point for comparison. Repeat measure analysis adjusted for age, exposure duration and smoking status was used to measure the difference in hearing threshold between the two groups. Results Noise levels were measured in the factory at a mean of 82 dBA, with a range of 66-97. No concurrent measurements were taken for the firefighters, but historic comparison values showed a wider range but a similar mean of 76-79 dBA. Although losses during follow-up were negligible, the factory workers had significantly (P 25 dB loss. Firefighters also showed increased losses associated with longer exposure duration, but these were significantly less marked. Losses at lower frequencies ( Conclusions Korean work environments with continuous noise exposure in the measured range should consider implementation of a hearing conservation program. Further evaluation of hearing loss in workers exposed to irregular or intermittent high noise levels, such as firefighters, is also warranted.

  15. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    Science.gov (United States)

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  16. The Queensland study of Melanoma: Environmental and Genetic Associations (Q-MEGA). Study design, baseline characteristics, and repeatability of phenotype and sun exposure measures

    Science.gov (United States)

    Baxter, Amanda J.; Hughes, Maria Celia; Kvaskoff, Marina; Siskind, Victor; Shekar, Sri; Aitken, Joanne F.; Green, Adele C.; Duffy, David L.; Hayward, Nicholas K.; Martin, Nicholas G.; Whiteman, David C.

    2013-01-01

    Cutaneous malignant melanoma (CMM) is a major health issue in Queensland, Australia which has the world’s highest incidence. Recent molecular and epidemiologic studies suggest that CMM arises through multiple etiological pathways involving gene-environment interactions. Understanding the potential mechanisms leading to CMM requires larger studies than those previously conducted. This article describes the design and baseline characteristics of Q-MEGA, the Queensland study of Melanoma: Environmental and Genetic Associations, which followed-up four population-based samples of CMM patients in Queensland, including children, adolescents, men aged over 50, and a large sample of adult cases and their families, including twins. Q-MEGA aims to investigate the roles of genetic and environmental factors, and their interaction, in the etiology of melanoma. 3,471 participants took part in the follow-up study and were administered a computer-assisted telephone interview in 2002–2005. Updated data on environmental and phenotypic risk factors, and 2,777 blood samples were collected from interviewed participants as well as a subset of relatives. This study provides a large and well-described population-based sample of CMM cases with follow-up data. Characteristics of the cases and repeatability of sun exposure and phenotype measures between the baseline and the follow-up surveys, from six to 17 years later, are also described. PMID:18361720

  17. Information Management for Factory Planning and Design

    OpenAIRE

    Chen, Danfang

    2012-01-01

    This thesis is dedicated to the manufacturing industry for the improvement of information management within the factory planningand design domain, and for more efficient factory planning and design. Currently the manufacturing industry lacks sufficient methods for capturing, structuring, and representing information and knowledge for easy access, exchange, integration and reuse within the domain. Therefore the focus of this thesis is on information and knowledge management within factory plan...

  18. WQO is Decidable for Factorial Languages

    KAUST Repository

    Atminas, Aistis

    2017-08-08

    A language is factorial if it is closed under taking factors, i.e. contiguous subwords. Every factorial language can be described by an antidictionary, i.e. a minimal set of forbidden factors. We show that the problem of deciding whether a factorial language given by a finite antidictionary is well-quasi-ordered under the factor containment relation can be solved in polynomial time. We also discuss possible ways to extend our solution to permutations and graphs.

  19. Preserving the Modernist Vertical Urban Factory

    Directory of Open Access Journals (Sweden)

    Nina Rappaport

    2016-07-01

    Full Text Available This essay is adapted in part, from the section, “Modern Factory Architecture” case studies from Nina Rappaport’s book Vertical Urban Factory, published by Actar this spring. Vertical Urban Factory began as an architecture studio, and then an exhibition, which opened in New York in 2011 and traveled to Detroit and Toronto in 2012. Last year the show was displayed at Archizoom at EPFL in Lausanne; Industry City, Brooklyn; and the Charles Moore School of Architecture at Kean University, in New Jersey. The project continues as a think tank evaluating factory futures and urban industrial potential.

  20. Effect of exposure to evening light on sleep initiation in the elderly: a longitudinal analysis for repeated measurements in home settings.

    Science.gov (United States)

    Obayashi, Kenji; Saeki, Keigo; Iwamoto, Junko; Okamoto, Nozomi; Tomioka, Kimiko; Nezu, Satoko; Ikada, Yoshito; Kurumatani, Norio

    2014-05-01

    Epidemiologic data have demonstrated associations of sleep-onset insomnia with a variety of diseases, including depression, dementia, diabetes and cardiovascular diseases. Sleep initiation is controlled by the suprachiasmatic nucleus of the hypothalamus and endogenous melatonin, both of which are influenced by environmental light. Exposure to evening light is hypothesized to cause circadian phase delay and melatonin suppression before bedtime, resulting in circadian misalignment and sleep-onset insomnia; however, whether exposure to evening light disturbs sleep initiation in home settings remains unclear. In this longitudinal analysis of 192 elderly individuals (mean age: 69.9 years), we measured evening light exposure and sleep-onset latency for 4 days using a wrist actigraph incorporating a light meter and an accelerometer. Mixed-effect linear regression analysis for repeated measurements was used to evaluate the effect of evening light exposure on subsequent sleep-onset latency. The median intensity of evening light exposure and the median sleep-onset latency were 27.3 lux (interquartile range, 17.9-43.4) and 17 min (interquartile range, 7-33), respectively. Univariate models showed significant associations between sleep-onset latency and age, gender, daytime physical activity, in-bed time, day length and average intensity of evening and nighttime light exposures. In a multivariate model, log-transformed average intensity of evening light exposure was significantly associated with log-transformed sleep-onset latency independent of the former potential confounding factors (regression coefficient, 0.133; 95% CI, 0.020-0.247; p = 0.021). Day length and nighttime light exposure were also significantly associated with log-transformed sleep-onset latency (p = 0.001 and p < 0.001, respectively). In conclusion, exposure to evening light in home setting prolongs subsequent sleep-onset latency in the elderly.

  1. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  2. Photon Factory activity report, 1987

    International Nuclear Information System (INIS)

    1987-01-01

    The Photon Factory made great strides in 1987. The low emittance operation of the PF ring was achieved in March, and resulted favorably in the increase of brilliance from 2 to 20 times for all the beam lines with high beam stability. At the same time, the installation of inserted devices was under way for all available straight sections of the ring. A 54-pole wiggler-undulator has been commissioned at BL-16. The devices to be inserted in the near future are a multipole wiggler for BL-13, an undulator for BL-19, and an undulator for circular polarized radiation at BL-28. The construction of beam lines continued, and four new beam lines, BL-6, BL-9, BL-16 and BL-17, are now in operation, BL-13 and BL-19 are under construction, and BL-3, BL-5, BL-18, BL-20 and BL-28 are in the design stage. Since its inauguration with four beam lines in 1982, the Photon Factory has grown rapidly, and approaches the goal of operating the PF ring with positrons in full use of its 24 beam ports and the straight sections for inserted devices. The total operation time was limited to 3,000 hours by the budget for fiscal year 1987, and about 80 % of the operation hours were devoted to the experiments of users. The nearly perfect operation of the 400 m long linac has continued in 1987, and has supplied both electrons and positrons to the TRISTAN collision experiment. The light source of a 2.5 GeV electron storage ring was normally operated. (Kako, I.)

  3. Construção e validação fatorial de uma medida de inteligência emocional Construction and factorial validation for a measurement of emotional intelligence

    Directory of Open Access Journals (Sweden)

    Mirlene Maria Matias Siqueira

    1999-08-01

    ,87; factor 2 sociability (13 items, alpha = 0,82; factor 3 self-motivation (12 items, alpha = 0,82; factor 4 self-control (10 items, alpha = 0,84, and factor 5 self-consciousness (10 items, alpha = 0,78. The method for measuring emotional intelligence resulting from this study opens possible avenues for future national research on the subject seeing that the measurement is factorially valid and has factors with levels of accuracy which indicate this measure to scientific applications.

  4. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... to missing data, 730 children were included in the current analytical sample. An accelerometer was worn for 7 days and 8 nights during autumn, winter and spring, from which physical activity, sedentary time and sleep duration were measured. Cardio-respiratory fitness was assessed using a 10-min intermittent...

  5. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    Science.gov (United States)

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies

  6. Synthetic food coloring and behavior: a dose response effect in a double-blind, placebo-controlled, repeated-measures study.

    Science.gov (United States)

    Rowe, K S; Rowe, K J

    1994-11-01

    To establish whether there is an association between the ingestion of synthetic food colorings and behavioral change in children referred for assessment of "hyperactivity." From approximately 800 children referred to the Royal Children's Hospital (Melbourne) for assessment of suspected hyperactivity, 200 were included in a 6-week open trial of a diet free of synthetic food coloring. The parents of 150 children reported behavioral improvement with the diet, and deterioration on the introduction of foods noted to contain synthetic coloring. A 30-item behavioral rating inventory was devised from an examination of the clinical histories of 50 suspected reactors. Thirty-four other children (23 suspected reactors, 11 uncertain reactors) and 20 control subjects, aged 2 to 14 years, were studied. A 21-day, double-blind, placebo-controlled, repeated-measures study used each child as his or her own control. Placebo, or one of six dose levels of tartrazine (1, 2, 5, 10, 20, 50 mg), was administered randomly each morning, and behavioral ratings were recorded by parents at the end of each 24 hours. The study identified 24 children as clear reactors (19 of 23 "suspected reactors," 3 of 11 "uncertain reactors," and 2 of 20 "control subjects"). They were irritable and restless and had sleep disturbance. Significant reactions were observed at all six dose levels. A dose response effect was obtained. With a dose increase greater than 10 mg, the duration of effect was prolonged. Behavioral changes in irritability, restlessness, and sleep disturbance are associated with the ingestion of tartrazine in some children. A dose response effect was observed.

  7. Knowledge and Skill Retention of In-Service versus Preservice Nursing Professionals following an Informal Training Program in Pediatric Cardiopulmonary Resuscitation: A Repeated-Measures Quasiexperimental Study

    Directory of Open Access Journals (Sweden)

    Jhuma Sankar

    2013-01-01

    Full Text Available Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses and final year undergraduate nursing students (preservice nurses using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants—28 in-service and 46 preservice professionals—were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P=0.08 while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P<0.001. Immediately after training, the scores improved in both groups. At 6 weeks however, we observed a nonuniform decline in performance in both groups—in-service nurses performing better in knowledge test (10.5 versus 9.1, P=0.01 and the preservice nurses performing better in skill test (9.8 versus 7.4, P<0.001. Thus, knowledge and skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  8. A Tau-Charm Factory at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Seth, K.K. [Northwestern Univ., Evanston, IL (United States)

    1994-04-01

    It is proposed that a Tau Charm Factory represents a natural extension of CEBAF into higher energy domains. The exciting nature of the physics of charm quarks and tau leptons is briefly reviewed and it is suggested that the concept of a linac-ring collider as a Tau Charm Factory at CEBAF should be seriously studied.

  9. Phenomenology of neutrino oscillations at the neutrino factory

    International Nuclear Information System (INIS)

    Tang, Jian

    2011-01-01

    We consider the prospects for a neutrino factory measuring mixing angles, the CP violating phase and mass-squared differences by detecting wrong-charge muons arising from the chain μ + → ν e → ν μ → μ - and the right-charge muons coming from the chain μ + → anti ν μ → anti ν μ → μ - (similar to μ - chains), where ν e → ν μ and anti ν μ → anti ν μ are neutrino oscillation channels through a long baseline. First, we study physics with near detectors and consider the treatment of systematic errors including cross section errors, flux errors, and background uncertainties. We illustrate for which measurements near detectors are required, discuss how many are needed, and what the role of the flux monitoring is. We demonstrate that near detectors are mandatory for the leading atmospheric parameter measurements if the neutrino factory has only one baseline, whereas systematic errors partially cancel if the neutrino factory complex includes the magic baseline. Second, we perform the baseline and energy optimization of the neutrino factory including the latest simulation results from the magnetized iron neutrino detector (MIND). We also consider the impact of τ decays, generated by appearance channels ν μ → ν τ and ν e → ν τ , on the discovery reaches of the mass orderings, the leptonic CP violation, and the non-zero θ 13 , which we find to be negligible for the considered detector. Third, we make a comparison of a high energy neutrino factory to a low energy neutrino factory and find that they are just two versions of the same experiment optimized for different regions of the parameter space. In addition, we briefly comment on whether it is useful to build the bi-magic baseline at the low energy neutrino factory. Finally, the effects of one additional massive sterile neutrino are discussed in the context of a combined short and long baseline setup. It is found that near detectors can provide the required sensitivity at the

  10. Phenomenology of neutrino oscillations at the neutrino factory

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Jian

    2011-12-19

    We consider the prospects for a neutrino factory measuring mixing angles, the CP violating phase and mass-squared differences by detecting wrong-charge muons arising from the chain {mu}{sup +} {yields} {nu}{sub e} {yields} {nu}{sub {mu}} {yields} {mu}{sup -} and the right-charge muons coming from the chain {mu}{sup +} {yields} anti {nu}{sub {mu}} {yields} anti {nu}{sub {mu}} {yields} {mu}{sup -} (similar to {mu}{sup -} chains), where {nu}{sub e} {yields} {nu}{sub {mu}} and anti {nu}{sub {mu}} {yields} anti {nu}{sub {mu}} are neutrino oscillation channels through a long baseline. First, we study physics with near detectors and consider the treatment of systematic errors including cross section errors, flux errors, and background uncertainties. We illustrate for which measurements near detectors are required, discuss how many are needed, and what the role of the flux monitoring is. We demonstrate that near detectors are mandatory for the leading atmospheric parameter measurements if the neutrino factory has only one baseline, whereas systematic errors partially cancel if the neutrino factory complex includes the magic baseline. Second, we perform the baseline and energy optimization of the neutrino factory including the latest simulation results from the magnetized iron neutrino detector (MIND). We also consider the impact of {tau} decays, generated by appearance channels {nu}{sub {mu}} {yields} {nu}{sub {tau}} and {nu}{sub e} {yields} {nu}{sub {tau}}, on the discovery reaches of the mass orderings, the leptonic CP violation, and the non-zero {theta}{sub 13}, which we find to be negligible for the considered detector. Third, we make a comparison of a high energy neutrino factory to a low energy neutrino factory and find that they are just two versions of the same experiment optimized for different regions of the parameter space. In addition, we briefly comment on whether it is useful to build the bi-magic baseline at the low energy neutrino factory. Finally, the

  11. Photon Factory activity report, 1989

    International Nuclear Information System (INIS)

    1990-01-01

    At the Photon Factory about 500 experiments are now running annually with about 50 experimental stations, the total operation time of the 2.5 GeV storage ring was 3400 hour in 1989, and the number of users was more than 2000, including 300 scientists from industry. This wide usage of synchrotron radiation has been supported by good performance of the accelerators. The positron beam current of the linac was increased for rapid injection (injection time: 20 min). The entire roof of the Light Source building was covered with thermal insulator (urethane-foam). This has greatly improved the beam stability of the ring. It has been operated at an initial ring current of 350 mA with a life time of 20 hours. Distinctive instrumentation at the Photon Factory has expanded to various fields such as angle-resolved ion-spectroscopy, dispersive EXAFS, trace impurity X-ray fluorescence analysis, plane-wave topography, structure analysis under high pressure, and imaging plates. Recently, experiments of protein structure analysis have been carried out extensively; Sakabe developed a new type of Weissenberg camera for protein crystallography, and about 50 experiments have been done for the past six months by a combination of Sakabe camera and imaging plates. The 2.5 GeV light source is now at an entrance of its harvest season. The TRISTAN Accumulation Ring has been used throughout this year in a time sharing basis with the TRISTAN experiment; twenty minutes for injection to TRISTAN Main Ring and 2 hours for SR experiment. The main subject has been magnetic Compton scattering with circularly polarized wiggler radiation. Such experiences enable us to expand our perspective for research in the following decade; we are investigating the possibility of operating the TRISTAN Main Ring at 6-8 GeV with 6000-pole undulaters, resulting in an extremely brilliant radiation source (Emittance: 0.1 nm·rad at 5 GeV with damping rings). (J.P.N.)

  12. Avaliação do desempenho zootécnico de genótipos de frangos de corte utilizando-se a análise de medidas repetidas Performance evaluation of broiler genotypes by repeated measures

    Directory of Open Access Journals (Sweden)

    Millor Fernandes do Rosário

    2005-12-01

    . Four genotypes (A, B, C, and D and two sexes were evaluated at six ages (7, 14, 21, 28, 35, and 42 days for average feed intake (AFI, average body weight (ABW and feed:gain ratio (F/G using an unbalanced incomplete blocks 4x2 factorial design. Five error co(variance structures were tested using the MIXED procedure of SAS® for statistical analyses. Averages were estimated by least squares and compared by the Tukey-Kramer test. Quadratic profile analyses for AFI and F/G and Gompertz growth model for ABW and respective coefficients of determination were estimated by NLIN procedure of SAS®. Significant effects of some triple or double interactions were observed for all response variables. Genotypes signicantly diferred in each age and sex for AFI and ABW after 21 days of age and diferences for F/G between genotypes and sexes, in each age, were verified only at 42 days of age. Larger averages for AFI and ABW was observed for genotype D and smaller F/G was verified in genotypes C and B. Estimated profile analyses explained adequately each response variable in function of age. AFI and ABW for males of genotype D were larger after 14 days and from 28 to 42 days their performance diferred from the other genotypes. The best F/G was observed in males of the genotype C. Overall, genotypes C and B presented the best performance. The repeated measurements approach was approppriate to evaluate diferences in the performance of broiler genotypes.

  13. Mobile monitoring and embedded control system for factory environment.

    Science.gov (United States)

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  14. Feasibility study for an asymmetric B-factory at KEK

    International Nuclear Information System (INIS)

    Ozaki, Hitoshi; Yoshimura, Yoshio

    1990-06-01

    In June, 1989, the study group for exploring the feasibility of B meson physics using an asymmetric energy accelerator was organized. This report is the summary of the results of the works that this study group carried out in nine months, and is the Japanese edition of the report of English edition 'Task Force Report on Asymmetric B-factory at KEK'. The activity plan of the study group was to make up the plan exceeding the preceding CLEO-2 experiment by utilizing the features of an asymmetric B-factory. Under this plan, the activities have been carried out by the study meetings twice every week on the physics side and once every two weeks on the accelerator side. Besides, in two study meetings held in October and December, 1989, several persons who have engaged in the research on B meson physics actually in foreign countries were invited, and the discussion was carried out. At present toward the materialization of the plan, the concrete investigation of accelerators and measuring instruments was begun. The significance of a B-factory and the construction project, the physics of a B-factory, the experimental method and the plan for an accelerator are reported. (K.I.)

  15. Mobile Monitoring and Embedded Control System for Factory Environment

    Science.gov (United States)

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-01-01

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones. PMID:24351642

  16. Mobile Monitoring and Embedded Control System for Factory Environment

    Directory of Open Access Journals (Sweden)

    Kuang-Yow Lian

    2013-12-01

    Full Text Available This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC technology is used to carry out the actual electricity load experiments using smart phones.

  17. The KAON Factory at TRIUMF

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1992-08-01

    The TRIUMF KAON Factory is designed to produce beams of kaons, antiprotons, other hadrons and neutrinos 100 times more intense, or cleaner, than are available now, for a broad range of particle and nuclear physics experiments. This will require a 100 μA beam of 30 GeV protons, to be produced by an interleaved sequence of two fast-cycling synchrotrons and three storage rings, with the existing TRIUMF H - cyclotron as injector. An $11-million preconstruction study has enabled the overall design to be reviewed and prototypes of various components to be built and evaluated -fast-cycling dipole and quadrupole magnets, a dual-frequency magnet power supply, ceramic beam pipes with internal rf shields, and rf cavity (using perpendicular bias), an extraction kicker, and rf beam chopper, and production targets. Environmental, industrial and economic impact studies have also been completed and the cost estimates and schedule updated. The total cost of $708 million (Canadian) will be shared equally between Canada, British Columbia and international contributors: the first two-thirds of this sum have already been approved and negotiations for the remainder are under way. 25 refs., 7 figs

  18. The KAON factory at TRIUMF

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1992-07-01

    The TRIUMF KAON Factory is designed to produce beams of kaons, antiprotons, other hadrons and neutrinos 100 times more intense, or cleaner, than are available now, for a broad range of particle and nuclear physics experiments. This will require a 100 μA beam of 30 GeV protons, to be produced by an interleaved sequence of two fast-cycling synchrotrons and three storage rings, with the existing TRIUMF H - cyclotron as injector. An $11-million pre-construction study has enabled the overall design to be reviewed and prototypes of various components to be built and evaluated: fast-cycling dipole and quadrupole magnets, a dual frequency magnet power supply, ceramic beam pipes with internal rf shields, an rf cavity (using perpendicular bias), an extraction kicker, an rf beam chopper, and production targets. Environmental, industrial and economic impact studies have also been completed and the cost estimates and schedule updated. The total cost of $708 million (Canadian) will be shared equally between Canada, British Columbia and international contributors; the first two-thirds of this sum have already been approved and negotiations for the remainder are under way. 26 refs., 6 figs

  19. Factorial structure of aerobics athletes’ fitness

    Directory of Open Access Journals (Sweden)

    T.V. Shepelenko

    2017-11-01

    Full Text Available The purpose of the research is to develop an algorithm of teams’ formation in sport aerobics and to define factorial structure of athletes’ fitness. Material : in the research sport aerobics’ athletes (n=19 participated. All athletes are members of Kharkiv national team (Ukraine. All athletes underwent complete medical examination. The functional condition of an organism (arterial blood pressure, indicators of a variability of the rhythm of the heart, treadbahn testing, psycho-physiological state (time’s determination of simple and complex reaction were defined. The physical development and physical fitness and stability of vestibular system were also defined. The factorial and cluster analysis were used. Results : The algorithm of teams’ formation in sport aerobics is developed for performances in various competitive categories. The algorithm contains all stages of standard procedure of the factorial and cluster analysis. In the factorial analysis the individual factorial values were also defined. Conclusions : The obtained data are recommended to be used at teams’ formation for performances in various competitive categories: team formation for pair and group performances. The general and individual factorial structure of athletes’ complex fitness is defined. It is possible to select athletes with similar qualities and with different qualities for the mixed performances. The determination of individual factorial structure of fitness permits to estimate objectively variants of athletes’ formation in groups.

  20. Reproducibility of repeated measures of deuterium substituted [11C]L-deprenyl ([11C]L-deprenyl-D2) binding in the human brain

    International Nuclear Information System (INIS)

    Logan, Jean; Fowler, Joanna S.; Volkow, Nora D.; Wang, Gene-Jack; MacGregor, Robert R.; Shea, Colleen

    2000-01-01

    The purpose of this study was to assess the reproducibility of repeated positron emission tomography (PET) measures of brain monoamine oxidase B (MAO B) using deuterium-substituted [ 11 C]L-deprenyl ([ 11 C]L-deprenyl-D2) in normal subjects and to validate the method used for estimating the kinetic constants from the irreversible 3-compartment model applied to the tracer binding. Five normal healthy subjects (age range 23-73 years) each received two PET scans with [ 11 C]L-deprenyl-D2. The time interval between scans was 7-27 days. Time-activity data from eight regions of interest and an arterial plasma input function was used to calculate λk 3 , a model term proportional to MAO B, and K 1 , the plasma to brain transfer constant that is related to blood flow. Linear (LIN) and nonlinear least-squares (NLLSQ) estimation methods were used to calculate the optimum model constants. A comparison of time-activity curves for scan 1 and scan 2 showed that the percent of change for peak uptake varied from -18.5 to 15.0% and that increases and decreases in uptake on scan 2 were associated with increases and decreases in the value of the arterial input of the tracer. Calculation of λk 3 showed a difference between scan 1 and scan 2 in the global value ranging between -6.97 and 4.5% (average -2.1±4.7%). The average percent change for eight brain regions for the five subjects was -2.84±7.07%. Values of λk 3 for scan 1 and scan 2 were highly correlated (r 2 =0.98; p 1 showed a significant correlation between scan 1 and scan 2 (r 2 =0.61; p 11 C]L-deprenyl-D2 varied between scan 1 and scan 2, driven by the differences in arterial tracer input. Application of a 3-compartment model to regional time-activity data and arterial input function yielded λk 3 values for scan 1 and scan 2 with an average difference of -2.84 ± 7.07%. Linear regression applied to values of λk 3 from the LIN and NLLSQ methods validated the use of the linear method for calculating λk 3

  1. Evaluation of a Direct-Instruction Intervention to Improve Movement and Preliteracy Skills among Young Children: A Within-Subject Repeated-Measures Design.

    Science.gov (United States)

    Bedard, Chloe; Bremer, Emily; Campbell, Wenonah; Cairney, John

    2017-01-01

    School readiness involves the development of foundational skills such as emergent literacy and fundamental movement skills as well as the capacity to attentively engage in instructional situations. Children do not develop these skills naturally; therefore, they need the opportunity to develop these skills in their early years prior to entering school. The objective of the current study was to evaluate the effectiveness and feasibility of a direct-instruction movement and preliteracy intervention in children aged 3-4 years. A within-subject repeated-measures design, embedded within a wait-list control study, was used to evaluate the intervention. The intervention was run across 10 weeks with 1 h weekly sessions. Each weekly session consisted of 30-min of movement skill instruction (e.g., through single-step acquisition strategies), 15-min of free play during which time children had access to a variety of equipment (e.g., balls, hula hoops, etc.) or toys (e.g., puzzles, building blocks), and a 15-min interactive reading circle during which children read a storybook and were taught 1-2 preliteracy skills (e.g., alphabet knowledge, narrative knowledge, etc.). A convenience sample of 11 children (mean age = 45.6 months, SD = 7.3) was recruited. All children were assessed four times: baseline (Time 1), pre-intervention (Time 2), post-intervention (Time 3), and 5-week follow-up (Time 4). Gross motor skills and preliteracy skills were assessed at each time point. There was a statistically significant effect of time on the change in gross motor skills (Wilks' lambda = 0.09, p  = .002), print-concept skills (Wilks' lambda = 0.09, p  = .001), and alphabet knowledge (Wilks' lambda = 0.29, p  = .046). Post hoc analyses reveal non-significant changes between time 1 and 2 for motor and print-concept skills and significant changes in all three outcomes between time 2 and time 3. Participation in a direct-instruction movement and preliteracy

  2. Evaluation of a Direct-Instruction Intervention to Improve Movement and Preliteracy Skills among Young Children: A Within-Subject Repeated-Measures Design

    Directory of Open Access Journals (Sweden)

    Chloe Bedard

    2018-01-01

    Full Text Available ObjectiveSchool readiness involves the development of foundational skills such as emergent literacy and fundamental movement skills as well as the capacity to attentively engage in instructional situations. Children do not develop these skills naturally; therefore, they need the opportunity to develop these skills in their early years prior to entering school. The objective of the current study was to evaluate the effectiveness and feasibility of a direct-instruction movement and preliteracy intervention in children aged 3–4 years.MethodsA within-subject repeated-measures design, embedded within a wait-list control study, was used to evaluate the intervention. The intervention was run across 10 weeks with 1 h weekly sessions. Each weekly session consisted of 30-min of movement skill instruction (e.g., through single-step acquisition strategies, 15-min of free play during which time children had access to a variety of equipment (e.g., balls, hula hoops, etc. or toys (e.g., puzzles, building blocks, and a 15-min interactive reading circle during which children read a storybook and were taught 1–2 preliteracy skills (e.g., alphabet knowledge, narrative knowledge, etc.. A convenience sample of 11 children (mean age = 45.6 months, SD = 7.3 was recruited. All children were assessed four times: baseline (Time 1, pre-intervention (Time 2, post-intervention (Time 3, and 5-week follow-up (Time 4. Gross motor skills and preliteracy skills were assessed at each time point.ResultsThere was a statistically significant effect of time on the change in gross motor skills (Wilks’ lambda = 0.09, p = .002, print-concept skills (Wilks’ lambda = 0.09, p = .001, and alphabet knowledge (Wilks’ lambda = 0.29, p = .046. Post hoc analyses reveal non-significant changes between time 1 and 2 for motor and print-concept skills and significant changes in all three outcomes between time 2 and time 3.ConclusionParticipation in a

  3. A probit- log- skew-normal mixture model for repeated measures data with excess zeros, with application to a cohort study of paediatric respiratory symptoms

    Directory of Open Access Journals (Sweden)

    Johnston Neil W

    2010-06-01

    Full Text Available Abstract Background A zero-inflated continuous outcome is characterized by occurrence of "excess" zeros that more than a single distribution can explain, with the positive observations forming a skewed distribution. Mixture models are employed for regression analysis of zero-inflated data. Moreover, for repeated measures zero-inflated data the clustering structure should also be modeled for an adequate analysis. Methods Diary of Asthma and Viral Infections Study (DAVIS was a one year (2004 cohort study conducted at McMaster University to monitor viral infection and respiratory symptoms in children aged 5-11 years with and without asthma. Respiratory symptoms were recorded daily using either an Internet or paper-based diary. Changes in symptoms were assessed by study staff and led to collection of nasal fluid specimens for virological testing. The study objectives included investigating the response of respiratory symptoms to respiratory viral infection in children with and without asthma over a one year period. Due to sparse data daily respiratory symptom scores were aggregated into weekly average scores. More than 70% of the weekly average scores were zero, with the positive scores forming a skewed distribution. We propose a random effects probit/log-skew-normal mixture model to analyze the DAVIS data. The model parameters were estimated using a maximum marginal likelihood approach. A simulation study was conducted to assess the performance of the proposed mixture model if the underlying distribution of the positive response is different from log-skew normal. Results Viral infection status was highly significant in both probit and log-skew normal model components respectively. The probability of being symptom free was much lower for the week a child was viral positive relative to the week she/he was viral negative. The severity of the symptoms was also greater for the week a child was viral positive. The probability of being symptom free was

  4. SatisFactory Final System Evaluation Report

    OpenAIRE

    Sunlight SA

    2018-01-01

    The present document is a deliverable of the SatisFactory project, funded by the European Commission’s Directorate-General for Research and Innovation (DG RTD), under its Horizon 2020 Research and innovation programme (H2020). The main objective of this deliverable is to report on the SatisFactory Final System Evaluation, with regards to the industrial pilots at COMAU and SUNLIGHT. The evaluation of SatisFactory platform is based on the implementation of the business scenarios where each tool...

  5. STANFORD (SLAC): B factory construction begins

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1994-03-15

    At a ceremony marking the start of construction, members of the US Congress and Secretary of Energy Hazel O'Leary hailed the new Asymmetric B Factory as the key to continued vitality of the Stanford Linear Accelerator Center (SLAC). Being built in collaboration with the Lawrence Berkeley Laboratory and the Lawrence Livermore National Laboratory, the B factory is a $177 million upgrade of the existing PEP electron-positron collider. Scheduled for completion in 1998, the B factory will generate many millions of B mesons, allowing, among other physics, an intensive search for the phenomena of CP violation in the decays of these particles.

  6. STANFORD (SLAC): B factory construction begins

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    At a ceremony marking the start of construction, members of the US Congress and Secretary of Energy Hazel O'Leary hailed the new Asymmetric B Factory as the key to continued vitality of the Stanford Linear Accelerator Center (SLAC). Being built in collaboration with the Lawrence Berkeley Laboratory and the Lawrence Livermore National Laboratory, the B factory is a $177 million upgrade of the existing PEP electron-positron collider. Scheduled for completion in 1998, the B factory will generate many millions of B mesons, allowing, among other physics, an intensive search for the phenomena of CP violation in the decays of these particles

  7. Deficits and Solutions in the Development of Modular Factory Systems

    OpenAIRE

    Achim Kampker; Peter Burggräf; Moritz Krunke; Hanno Voet

    2017-01-01

    As a reaction to current challenges in factory planning, many companies think about introducing factory standards to lower planning times and decrease planning costs. If these factory standards are set-up with a high level of modularity, they are defined as modular factory systems. This paper deals with the main current problems in the application of modular factory systems in practice and presents a solution approach with its basic models. The methodology is based on methods from factory pla...

  8. The factory as a battlefield

    Directory of Open Access Journals (Sweden)

    Helena Chávez Mac Gregor

    Full Text Available The crisis of labour is also one of representation. Some contemporary artists working with moving images have been questioning how to represent capital, labour and the worker. Isaac Julien or Harun Farocki, for example, have focused on interlacing characters - from fiction or reality - with geopolitical spaces in order to present the entanglement of the economical new order with the new forms of labour. The South African artist Simon Gush has shifted from this trend in order to present labour without directly representing the workers. In his artwork there is no longer a search for the political subject as a historical force or for the individuals who occupied its place; instead he leads viewers to a critical reading of an object, allowing a staging of the past from the viewpoint of the present. That is what I think Red does. In this article I explore Gush's connections with Marx, Benjamin and Steyerl to show how Gush's work is part of a critical tradition that has abandoned the subject as the privileged instance of political agency; turning the emphasis of the modern schema upside down, it focuses on the object as the force of emancipation. I would like to suggest that Gush used an object, Mandela's red Mercedes-Benz, to produce another image so that the story told is not necessarily that of a symbol of pacification, but one in which the factory was a battlefield. In this way I explore the emancipatory potencies of the object. What I propose is a reading of Red from the point of view of a return to the thing, where the latter becomes a political force.

  9. Energy usage in Beet Suger Factories. Sockerfabrikens energianvaendning; En systemstudie

    Energy Technology Data Exchange (ETDEWEB)

    Feltborg, G

    1990-02-01

    A computer program has been developed in order to simulate the energy consumption of beet sugar factories, for various plant configurations. The program is divided into five block units: Extraction and Juice purification, Juice concentration, Crystallization, Drying and finally the Power House. Each block consists of different modules, for example, a heat exchanger, an evaporator, a turbine and a dryer. The purpose of this project was to simulate some different system configurations of a sugar factory, whereby both new and previously used process technologies were utilized. The following parts of the process have been particularly emphasized: Power House - gas turbine, waste heat boiler. Drying - low-temperature dryer, steam dryer. Evaporation - vapour recompression. Crystallization - vapour recompression, continuous system. The different plant configurations have been compared to a reference factory, which is designed according to current technology used in a modern and well balanced Swedish factory. The comparisons are based upon the total power consumption as well as the total annual energy costs. Eleven different plant configurations were studied. The maximum power reduction is 36%, relative to the reference factory. The dissertation also contains an experimental study of a low-temperature drying process. The drying characteristics of pressed beet pulp were studied in a specially designed rotary dryer pilot plant. A number of parameters were varied i.e. the solid moisture content, air velocity, temperature and rotational speed. The results are given in terms of an apparent volumetric heat-transfer coefficient, determined from measured data. A mathematical model was established to determine the residence time of the material in the rotary dryer at different air velocities. (45 refs.).

  10. Measurements of Repeated Tightening and Loosening Torque of Seven Different Implant/Abutment Connection Designs and Their Modifications: An In Vitro Study.

    Science.gov (United States)

    Butkevica, Alena; Nathanson, Dan; Pober, Richard; Strating, Herman

    2018-02-01

    Repeated tightening and loosening of the abutment screw may alter its mechanical and physical properties affecting the optimal torque and ultimate reliability of an implant/abutment connection. The purpose of this study was to evaluate the effect of repeated tightening and loosening of implant/abutment screws on the loosening torque of implant/abutment connections of commercially available implant systems. Seven different implant/abutment connections and their modifications were tested. The screws of each system were tightened according to the manufacturer's specifications. After 20 minutes the screws were loosened. This procedure was repeated ten times, and the differences between the 1st and 10th cycle were expressed as a percentage change RTq(%) and correlated with initial torque, the number of threads, the length of shank, and thread surface area employing Spearman's analysis. All systems showed significant differences in residual torque (RTq) value (p 0.05). All connections but group 3 (p = 1.000) showed a significant change from the initial torque (ITq) to the RTq values. The first successive RTq values increased in two connection groups 1 and 2. The remaining connections showed reduced RTq values ranging from -1.2 % (group 5) to -23.5% (group 6). The RTq values declined gradually with every repeated tightening in groups 1, 2, 3, 8, 9, 11, 12. In group 2, after the tenth tightening the RTq was still above the ITq value. Only length of shank demonstrated a correlation with the RTq(%) change over the successive tightening loosening cycles (p abutment screws caused varying torque level changes among the different systems. These observations can probably be attributed to connection design. Limiting the number of tightening/loosening cycles in clinical and laboratory procedures is advisable for most of the implant systems tested. © 2016 by the American College of Prosthodontists.

  11. Physics opportunities for a B Factory

    International Nuclear Information System (INIS)

    Quinn, H.R.

    1992-02-01

    In the short time allotted for this talk it is not possible to review all the physics opportunities offered by a B Factory. I focus on the physics of CP Violation and the resulting tests of the Standard Model

  12. Benthic carbonate factories of the Phanerozoic

    NARCIS (Netherlands)

    Schlager, W.

    2003-01-01

    Marine carbonate precipitation occurs in three basic modes: abiotic (or quasi-abiotic), biotically induced, and biotically controlled. On a geologic scale, these precipitation modes combine to form three carbonate production systems, or "factories" in the benthic environment: (1) tropical

  13. Survey and alignment of photon factory storage ring at KEK

    International Nuclear Information System (INIS)

    Araki, A.; Honjo, I.; Katoh, M.; Kamiya, Y.; Kihara, M.

    1987-01-01

    The heights of the magnets for both the ring and the beam transport line (BT-line) have been periodically measured at the Photon Factory. The accumulated data showed that the ring was considerably declined due to the construction of the large experimental hall and the tunnel of the TRISTAN project, and that the BT-line also sank several centimeters at some locations. These displacements of the magnets produce a significantly large closed orbit distortion and the vertical dispersion

  14. The physics of the B factories

    CERN Document Server

    Bevan, A J; Mannel, Th; Prell, S; Yabsley, B D; Abe, K; Aihara, H; Anulli, F; Arnaud, N; Aushev, T; Beneke, M; Beringer, J; Bianchi, F; Bigi, I I; Bona, M; Brambilla, N; Brodzicka, J; Chang, P; Charles, M J; Cheng, C H; Cheng, H -Y; Chistov, R; Colangelo, P; Coleman, J P; Drutskoy, A; Druzhinin, V P; Eidelman, S; Eigen, G; Eisner, A M; Faccini, R; Flood, K T; Gambino, P; Gaz, A; Gradl, W; Hayashii, H; Higuchi, T; Hulsbergen, W D; Hurth, T; Iijima, T; Itoh, R; Jackson, P D; Kass, R; Kolomensky, Yu G; Kou, E; Križan, P; Kronfeld, A; Kumano, S; Kwon, Y J; Latham, T E; Leith, D W G S; Lüth, V; Martinez-Vidal, F; Meadows, B T; Mussa, R; Nakao, M; Nishida, S; Ocariz, J; Olsen, S L; Pakhlov, P; Pakhlova, G; Palano, A; Pich, A; Playfer, S; Poluektov, A; Porter, F C; Robertson, S H; Roney, J M; Roodman, A; Sakai, Y; Schwanda, C; Schwartz, A J; Seidl, R; Sekula, S J; Steinhauser, M; Sumisawa, K; Swanson, E S; Tackmann, F; Trabelsi, K; Uehara, S; Uno, S; van der Water, R; Vasseur, G; Verkerke, W; Waldi, R; Wang, M Z; Wilson, F F; Zupan, J; Zupanc, A; Adachi, I; Albert, J; Banerjee, Sw; Ben-Haim, E; Biassoni, P; Cahn, R N; Cartaro, C; Chauveau, J; Chen, C; Chiang, C C; Cowan, R; Dalseno, J; Davier, M; Davies, C; Dingfelder, J C; Echenard, B; Epifanov, D; Fulsom, B G; Gabareen, A M; Gary, J W; Godang, R; Graham, M T; Hafner, A; Hamilton, B; Hartmann, T; Hayasaka, K; Hearty, C; Iwasaki, Y; Khodjamirian, A; Kusaka, A; Kuzmin, A; Lafferty, G D; Lazzaro, A; Li, J; Lindemann, D; Long, O; Lusiani, A; Marchiori, G; Martinelli, M; Miyabayashi, K; Mizuk, R; Mohanty, G B; Muller, D R; Nakazawa, H; Ongmongkolkul, P; Pacetti, S; Palombo, F; Pedlar, T K; Piilonen, L E; Pilloni, A; Poireau, V; Prothmann, K; Pulliam, T; Rama, M; Ratcliff, B N; Roudeau, P; Schrenk, S; Schroeder, T; Schubert, K R; Shen, C P; Shwartz, B; Soffer, A; Solodov, E P; Somov, A; Starič, M; Stracka, S; Telnov, A V; Todyshev, K Yu; Tsuboyama, T; Uglov, T; Vinokurova, A; Walsh, J J; Watanabe, Y; Won, E; Wormser, G; Wright, D H; Ye, S; Zhang, C C; Abachi, S; Abashian, A; Abe, N; Abe, R; Abe, T; Abrams, G S; Adam, I; Adamczyk, K; Adametz, A; Adye, T; Agarwal, A; Ahmed, H; Ahmed, M; Ahmed, S; Ahn, B S; Ahn, H S; Aitchison, I J R; Akai, K; Akar, S; Akatsu, M; Akemoto, M; Akhmetshin, R; Akre, R; Alam, M S; Albert, J N; Aleksan, R; Alexander, J P; Alimonti, G; Allen, M T; Allison, J; Allmendinger, T; Alsmiller, J R G; Altenburg, D; Alwyn, K E; An, Q; Anderson, J; Andreassen, R; Andreotti, D; Andreotti, M; Andress, J C; Angelini, C; Anipko, D; Anjomshoaa, A; Anthony, P L; Antillon, E A; Antonioli, E; Aoki, K; Arguin, J F; A, K; Arisaka, K; Asai, K; Asai, M; Asano, Y; Asgeirsson, D J; Asner, D M; Aso, T; Aspinwall, M L; Aston, D; Atmacan, H; Aubert, B; Aulchenko, V; Ayad, R; Azemoon, T; Aziz, T; Azzolini, V; Azzopardi, D E; Baak, M A; Back, J J; Bagnasco, S; Bahinipati, S; Bailey, D S; Bailey, S; Bailly, P; van Bakel, N; Bakich, A M; Bala, A; Balagura, V; Baldini-Ferroli, R; Ban, Y; Banas, E; Band, H R; Banerjee, S; Baracchini, E; Barate, R; Barberio, E; Barbero, M; Bard, D J; Barillari, T; Barlow, N R; Barlow, R J; Barrett, M; Bartel, W; Bartelt, J; Bartoldus, R; Batignani, G; Battaglia, M; Bauer, J M; Bay, A; Beaulieu, M; Bechtle, P; Beck, T W; Becker, J; Becla, J; Bedny, I; Behari, S; Behera, P K; Behn, E; Behr, L; Beigbeder, C; Beiline, D; Bell, R; Bellini, F; Bellis, M; Bellodi, G; Belous, K; Benayoun, M; Benelli, G; Benitez, J F; Benkebil, M; Berger, N; Bernabeu, J; Bernard, D; Bernet, R; Bernlochner, F U; Berryhill, J W; Bertsche, K; Besson, P; Best, D S; Bettarini, S; Bettoni, D; Bhardwaj, V; Bhimji, W; Bhuyan, B; Biagini, M E; Biasini, M; van Bibber, K; Biesiada, J; Bingham, I; Bionta, R M; Bischofberger, M; Bitenc, U; Bizjak, I; Blanc, F; Blaylock, G; Blinov, V E; Bloom, E; Bloom, P C; Blount, N L; Blouw, J; Bly, M; Blyth, S; Boeheim, C T; Bomben, M; Bondar, A; Bondioli, M; Bonneaud, G R; Bonvicini, G; Booke, M; Booth, J; Borean, C; Borgland, A W; Borsato, E; Bosi, F; Bosisio, L; Botov, A A; Bougher, J; Bouldin, K; Bourgeois, P; Boutigny, D; Bowerman, D A; Boyarski, A M; Boyce, R F; Boyd, J T; Bozek, A; Bozzi, C; Bračko, M; Brandenburg, G; Brandt, T; Brau, B; Brau, J; Breon, A B; Breton, D; Brew, C; Briand, H; Bright-Thomas, P G; Brigljević, V; Britton, D I; Brochard, F; Broomer, B; Brose, J; Browder, T E; Brown, C L; Brown, C M; Brown, D N; Browne, M; Bruinsma, M; Brunet, S; Bucci, F; Buchanan, C; Buchmueller, O L; Bünger, C; Bugg, W; Bukin, A D; Bula, R; Bulten, H; Burchat, P R; Burgess, W; Burke, J P; Button-Shafer, J; Buzykaev, A R; Buzzo, A; Cai, Y; Calabrese, R; Calcaterra, A; Calderini, G; Camanzi, B; Campagna, E; Campagnari, C; Capra, R; Carassiti, V; Carpinelli, M; Carroll, M; Casarosa, G; Casey, B C K; Cason, N M; Castelli, G; Cavallo, N; Cavoto, G; Cecchi, A; Cenci, R; Cerizza, G; Cervelli, A; Ceseracciu, A; Chai, X; Chaisanguanthum, K S; Chang, M C; Chang, Y H; Chang, Y W; Chao, D S; Chao, M; Chao, Y; Charles, E; Chavez, C A; Cheaib, R; Chekelian, V; Chen, A; Chen, E; Chen, G P; Chen, H F; Chen, J -H; Chen, J C; Chen, K F; Chen, P; Chen, S; Chen, W T; Chen, X; Chen, X R; Chen, Y Q; Cheng, B; Cheon, B G; Chevalier, N; Chia, Y M; Chidzik, S; Chilikin, K; Chistiakova, M V; Cizeron, R; Cho, I S; Cho, K; Chobanova, V; Choi, H H F; Choi, K S; Choi, S K; Choi, Y; Choi, Y K; Christ, S; Chu, P H; Chun, S; Chuvikov, A; Cibinetto, G; Cinabro, D; Clark, A R; Clark, P J; Clarke, C K; Claus, R; Claxton, B; Clifton, Z C; Cochran, J; Cohen-Tanugi, J; Cohn, H; Colberg, T; Cole, S; Colecchia, F; Condurache, C; Contri, R; Convert, P; Convery, M R; Cooke, P; Copty, N; Cormack, C M; Corso, F Dal; Corwin, L A; Cossutti, F; Cote, D; Ramusino, A Cotta; Cottingham, W N; Couderc, F; Coupal, D P; Covarelli, R; Cowan, G; Craddock, W W; Crane, G; Crawley, H B; Cremaldi, L; Crescente, A; Cristinziani, M; Crnkovic, J; Crosetti, G; Cuhadar-Donszelmann, T; Cunha, A; Curry, S; D'Orazio, A; Dû, S; Dahlinger, G; Dahmes, B; Dallapiccola, C; Danielson, N; Danilov, M; Das, A; Dash, M; Dasu, S; Datta, M; Daudo, F; Dauncey, P D; David, P; Davis, C L; Day, C T; De Mori, F; De Domenico, G; De Groot, N; De la Vaissière, C; de la Vaissière, Ch; de Lesquen, A; De Nardo, G; de Sangro, R; De Silva, A; DeBarger, S; Decker, F J; Sanchez, P del Amo; Del Buono, L; Del Gamba, V; del Re, D; Della Ricca, G; Denig, A G; Derkach, D; Derrington, I M; DeStaebler, H; Destree, J; Devmal, S; Dey, B; Di Girolamo, B; Di Marco, E; Dickopp, M; Dima, M O; Dittrich, S; Dittongo, S; Dixon, P; Dneprovsky, L; Dohou, F; Doi, Y; Doležal, Z; Doll, D A; Donald, M; Dong, L; Dong, L Y; Dorfan, J; Dorigo, A; Dorsten, M P; Dowd, R; Dowdell, J; Drásal, Z; Dragic, J; Drummond, B W; Dubitzky, R S; Dubois-Felsmann, G P; Dubrovin, M S; Duh, Y C; Duh, Y T; Dujmic, D; Dungel, W; Dunwoodie, W; Dutta, D; Dvoretskii, A; Dyce, N; Ebert, M; Eckhart, E A; Ecklund, S; Eckmann, R; Eckstein, P; Edgar, C L; Edwards, A J; Egede, U; Eichenbaum, A M; Elmer, P; Emery, S; Enari, Y; Enomoto, R; Erdos, E; Erickson, R; Ernst, J A; Erwin, R J; Escalier, M; Eschenburg, V; Eschrich, I; Esen, S; Esteve, L; Evangelisti, F; Everton, C W; Eyges, V; Fabby, C; Fabozzi, F; Fahey, S; Falbo, M; Fan, S; Fang, F; Fanin, C; Farbin, A; Farhat, H; Fast, J E; Feindt, M; Fella, A; Feltresi, E; Ferber, T; Fernholz, R E; Ferrag, S; Ferrarotto, F; Ferroni, F; Field, R C; Filippi, A; Finocchiaro, G; Fioravanti, E; da Costa, J Firmino; Fischer, P -A; Fisher, A; Fisher, P H; Flacco, C J; Flack, R L; Flaecher, H U; Flanagan, J; Flanigan, J M; Ford, K E; Ford, W T; Forster, I J; Forti, A C; Forti, F; Fortin, D; Foster, B; Foulkes, S D; Fouque, G; Fox, J; Franchini, P; Sevilla, M Franco; Franek, B; Frank, E D; Fransham, K B; Fratina, S; Fratini, K; Frey, A; Frey, R; Friedl, M; Fritsch, M; Fry, J R; Fujii, H; Fujikawa, M; Fujita, Y; Fujiyama, Y; Fukunaga, C; Fukushima, M; Fullwood, J; Funahashi, Y; Funakoshi, Y; Furano, F; Furman, M; Furukawa, K; Futterschneider, H; Gabathuler, E; Gabriel, T A; Gabyshev, N; Gaede, F; Gagliardi, N; Gaidot, A; Gaillard, J -M; Gaillard, J R; Galagedera, S; Galeazzi, F; Gallo, F; Gamba, D; Gamet, R; Gan, K K; Gandini, P; Ganguly, S; Ganzhur, S F; Gao, Y Y; Gaponenko, I; Garmash, A; Tico, J Garra; Garzia, I; Gaspero, M; Gastaldi, F; Gatto, C; Gaur, V; Geddes, N I; Geld, T L; Genat, J -F; George, K A; George, M; George, S; Georgette, Z; Gershon, T J; Gill, M S; Gillard, R; Gilman, J D; Giordano, F; Giorgi, M A; Giraud, P -F; Gladney, L; Glanzman, T; Glattauer, R; Go, A; Goetzen, K; Goh, Y M; Gokhroo, G; Goldenzweig, P; Golubev, V B; Gopal, G P; Gordon, A; Gorišek, A; Goriletsky, V I; Gorodeisky, R; Gosset, L; Gotow, K; Gowdy, S J; Graffin, P; Grancagnolo, S; Grauges, E; Graziani, G; Green, M G; Greene, M G; Grenier, G J; Grenier, P; Griessinger, K; Grillo, A A; Grinyov, B V; Gritsan, A V; Grosdidier, G; Perdekamp, M Grosse; Grosso, P; Grothe, M; Groysman, Y; Grünberg, O; Guido, E; Guler, H; Gunawardane, N J W; Guo, Q H; Guo, R S; Guo, Z J; Guttman, N; Ha, H; Ha, H C; Haas, T; Haba, J; Hachtel, J; Hadavand, H K; Hadig, T; Hagner, C; Haire, M; Haitani, F; Haji, T; Haller, G; Halyo, V; Hamano, K; Hamasaki, H; de Monchenault, G Hamel; Hamilton, J; Hamilton, R; Hamon, O; Han, B Y; Han, Y L; Hanada, H; Hanagaki, K; Handa, F; Hanson, J E; Hanushevsky, A; Hara, K; Hara, T; Harada, Y; Harrison, P F; Harrison, T J; Harrop, B; Hart, A J; Hart, P A; Hartfiel, B L; Harton, J L; Haruyama, T; Hasan, A; Hasegawa, Y; Hast, C; Hastings, N C; Hasuko, K; Hauke, A; Hawkes, C M; Hayashi, K; Hazumi, M; Hee, C; Heenan, E M; Heffernan, D; Held, T; Henderson, R; Henderson, S W; Hertzbach, S S; Hervé, S; Heß, M; Heusch, C A; Hicheur, A; Higashi, Y; Higasino, Y; Higuchi, I; Hikita, S; Hill, E J; Himel, T; Hinz, L; Hirai, T; Hirano, H; Hirschauer, J F; Hitlin, D G; Hitomi, N; Hodgkinson, M C; Höcker, A; Hoi, C T; Hojo, T; Hokuue, T; Hollar, J J; Hong, T M; Honscheid, K; Hooberman, B; Hopkins, D A; Horii, Y; Hoshi, Y; Hoshina, K; Hou, S; Hou, W S; Hryn'ova, T; Hsiung, Y B; Hsu, C L; Hsu, S C; Hu, H; Hu, T; Huang, H C; Huang, T J; Huang, Y C; Huard, Z; Huffer, M E; Hufnagel, D; Hung, T; Hutchcroft, D E; Hyun, H J; Ichizawa, S; Igaki, T; Igarashi, A; Igarashi, S; Igarashi, Y; Igonkina, O; Ikado, K; Ikeda, H; Ikeda, K; Ilic, J; Inami, K; Innes, W R; Inoue, Y; Ishikawa, A; Ishino, H; Itagaki, K; Itami, S; Itoh, K; Ivanchenko, V N; Iverson, R; Iwabuchi, M; Iwai, G; Iwai, M; Iwaida, S; Iwamoto, M; Iwasaki, H; Iwasaki, M; Iwashita, T; Izen, J M; Jackson, D J; Jackson, F; Jackson, G; Jackson, P S; Jacobsen, R G; Jacoby, C; Jaegle, I; Jain, V; Jalocha, P; Jang, H K; Jasper, H; Jawahery, A; Jayatilleke, S; Jen, C M; Jensen, F; Jessop, C P; Ji, X B; John, M J J; Johnson, D R; Johnson, J R; Jolly, S; Jones, M; Joo, K K; Joshi, N; Joshi, N J; Judd, D; Julius, T; Kadel, R W; Kadyk, J A; Kagan, H; Kagan, R; Kah, D H; Kaiser, S; Kaji, H; Kajiwara, S; Kakuno, H; Kameshima, T; Kaminski, J; Kamitani, T; Kaneko, J; Kang, J H; Kang, J S; Kani, T; Kapusta, P; Karbach, T M; Karolak, M; Karyotakis, Y; Kasami, K; Katano, G; Kataoka, S U; Katayama, N; Kato, E; Kato, Y; Kawai, H; Kawai, M; Kawamura, N; Kawasaki, T; Kay, J; Kay, M; Kelly, M P; Kelsey, M H; Kent, N; Kerth, L T; Khan, A; Khan, H R; Kharakh, D; Kibayashi, A; Kichimi, H; Kiesling, C; Kikuchi, M; Kikutani, E; Kim, B H; Kim, C H; Kim, D W; Kim, H; Kim, H J; Kim, H O; Kim, H W; Kim, J B; Kim, J H; Kim, K T; Kim, M J; Kim, P; Kim, S K; Kim, S M; Kim, T H; Kim, Y I; Kim, Y J; King, G J; Kinoshita, K; Kirk, A; Kirkby, D; Kitayama, I; Klemetti, M; Klose, V; Klucar, J; Knecht, N S; Knoepfel, K J; Knowles, D J; Ko, B R; Kobayashi, N; Kobayashi, S; Kobayashi, T; Kobel, M J; Koblitz, S; Koch, H; Kocian, M L; Kodyš, P; Koeneke, K; Kofler, R; Koike, S; Koishi, S; Koiso, H; Kolb, J A; Kolya, S D; Kondo, Y; Konishi, H; Koppenburg, P; Koptchev, V B; Kordich, T M B; Korol, A A; Korotushenko, K; Korpar, S; Kouzes, R T; Kovalskyi, D; Kowalewski, R; Kozakai, Y; Kozanecki, W; Kral, J F; Krasnykh, A; Krause, R; Kravchenko, E A; Krebs, J; Kreisel, A; Kreps, M; Krishnamurthy, M; Kroeger, R; Kroeger, W; Krokovny, P; Kronenbitter, B; Kroseberg, J; Kubo, T; Kuhr, T; Kukartsev, G; Kulasiri, R; Kulikov, A; Kumar, R; Kumar, S; Kumita, T; Kuniya, T; Kunze, M; Kuo, C C; Kuo, T -L; Kurashiro, H; Kurihara, E; Kurita, N; Kuroki, Y; Kurup, A; Kutter, P E; Kuznetsova, N; Kvasnička, P; Kyberd, P; Kyeong, S H; Lacker, H M; Lae, C K; Lamanna, E; Lamsa, J; Lanceri, L; Landi, L; Lang, M I; Lange, D J; Lange, J S; Langenegger, U; Langer, M; Lankford, A J; Lanni, F; Laplace, S; Latour, E; Lau, Y P; Lavin, D R; Layter, J; Lebbolo, H; LeClerc, C; Leddig, T; Leder, G; Diberder, F Le; Lee, C L; Lee, J; Lee, J S; Lee, M C; Lee, M H; Lee, M J; Lee, S -J; Lee, S E; Lee, S H; Lee, Y J; Lees, J P; Legendre, M; Leitgab, M; Leitner, R; Leonardi, E; Leonidopoulos, C; Lepeltier, V; Leruste, Ph; Lesiak, T; Levi, M E; Levy, S L; Lewandowski, B; Lewczuk, M J; Lewis, P; Li, H; Li, H B; Li, S; Li, X; Li, Y; Gioi, L Li; Libby, J; Lidbury, J; Lillard, V; Lim, C L; Limosani, A; Lin, C S; Lin, J Y; Lin, S W; Lin, Y S; Lindquist, B; Lindsay, C; Lista, L; Liu, C; Liu, F; Liu, H; Liu, H M; Liu, J; Liu, R; Liu, T; Liu, Y; Liu, Z Q; Liventsev, D; Vetere, M Lo; Locke, C B; Lockman, W S; Di Lodovico, F; Lombardo, V; London, G W; Pegna, D Lopes; Lopez, L; Lopez-March, N; Lory, J; LoSecco, J M; Lou, X C; Louvot, R; Lu, A; Lu, C; Lu, M; Lu, R S; Lueck, T; Luitz, S; Lukin, P; Lund, P; Luppi, E; Lutz, A M; Lutz, O; Lynch, G; Lynch, H L; Lyon, A J; Lyubinsky, V R; MacFarlane, D B; Mackay, C; MacNaughton, J; Macri, M M; Madani, S; Mader, W F; Majewski, S A; Majumder, G; Makida, Y; Malaescu, B; Malaguti, R; Malclès, J; Mallik, U; Maly, E; Mamada, H; Manabe, A; Mancinelli, G; Mandelkern, M; Mandl, F; Manfredi, P F; Mangeol, D J J; Manoni, E; Mao, Z P; Margoni, M; Marker, C E; Markey, G; Marks, J; Marlow, D; Marques, V; Marsiske, H; Martellotti, S; Martin, E C; Martin, J P; Martin, L; Martinez, A J; Marzolla, M; Mass, A; Masuzawa, M; Mathieu, A; Matricon, P; Matsubara, T; Matsuda, T; Matsumoto, H; Matsumoto, S; Matsumoto, T; Matsuo, H; Mattison, T S; Matvienko, D; Matyja, A; Mayer, B; Mazur, M A; Mazzoni, M A; McCulloch, M; McDonald, J; McFall, J D; McGrath, P; McKemey, A K; McKenna, J A; Mclachlin, S E; McMahon, S; McMahon, T R; McOnie, S; Medvedeva, T; Melen, R; Mellado, B; Menges, W; Menke, S; Merchant, A M; Merkel, J; Messner, R; Metcalfe, S; Metzler, S; Meyer, N T; Meyer, T I; Meyer, W T; Michael, A K; Michelon, G; Michizono, S; Micout, P; Miftakov, V; Mihalyi, A; Mikami, Y; Milanes, D A; Milek, M; Mimashi, T; Minamora, J S; Mindas, C; Minutoli, S; Mir, L M; Mishra, K; Mitaroff, W; Miyake, H; Miyashita, T S; Miyata, H; Miyazaki, Y; Moffitt, L C; Mohapatra, A; Mohapatra, A K; Mohapatra, D; Moll, A; Moloney, G R; Mols, J P; Mommsen, R K; Monge, M R; Monorchio, D; Moore, T B; Moorhead, G F; de Freitas, P Mora; Morandin, M; Morgan, N; Morgan, S E; Morganti, M; Morganti, S; Mori, S; Mori, T; Morii, M; Morris, J P; Morsani, F; Morton, G W; Moss, L J; Mouly, J P; Mount, R; Mueller, J; Müller-Pfefferkorn, R; Mugge, M; Muheim, F; Muir, A; Mullin, E; Munerato, M; Murakami, A; Murakami, T; Muramatsu, N; Musico, P; Nagai, I; Nagamine, T; Nagasaka, Y; Nagashima, Y; Nagayama, S; Nagel, M; Naisbit, M T; Nakadaira, T; Nakahama, Y; Nakajima, M; Nakajima, T; Nakamura, I; Nakamura, T; Nakamura, T T; Nakano, E; Nakayama, H; Nam, J W; Narita, S; Narsky, I; Nash, J A; Natkaniec, Z; Nauenberg, U; Nayak, M; Neal, H; Nedelkovska, E; Negrini, M; Neichi, K; Nelson, D; Nelson, S; Neri, N; Nesom, G; Neubauer, S; Newman-Coburn, D; Ng, C; Nguyen, X; Nicholson, H; Niebuhr, C; Nief, J Y; Niiyama, M; Nikolich, M B; Nisar, N K; Nishimura, K; Nishio, Y; Nitoh, O; Nogowski, R; Noguchi, S; Nomura, T; Nordby, M; Nosochkov, Y; Novokhatski, A; Nozaki, S; Nozaki, T; Nugent, I M; O'Grady, C P; O'Neale, S W; O'Neill, F G; Oberhof, B; Oddone, P J; Ofte, I; Ogawa, A; Ogawa, K; Ogawa, S; Ogawa, Y; Ohkubo, R; Ohmi, K; Ohnishi, Y; Ohno, F; Ohshima, T; Ohshima, Y; Ohuchi, N; Oide, K; Oishi, N; Okabe, T; Okazaki, N; Okazaki, T; Okuno, S; Olaiya, E O; Olivas, A; Olley, P; Olsen, J; Ono, S; Onorato, G; Onuchin, A P; Onuki, Y; Ooba, T; Orimoto, T J; Oshima, T; Osipenkov, I L; Ostrowicz, W; Oswald, C; Otto, S; Oyang, J; Oyanguren, A; Ozaki, H; Ozcan, V E; Paar, H P; Padoan, C; Paick, K; Palka, H; Pan, B; Pan, Y; Vazquez, W Panduro; Panetta, J; Panova, A I; Panvini, R S; Panzenböck, E; Paoloni, E; Paolucci, P; Pappagallo, M; Paramesvaran, S; Park, C S; Park, C W; Park, H; Park, H K; Park, K S; Park, W; Parry, R J; Parslow, N; Passaggio, S; Pastore, F C; Patel, P M; Patrignani, C; Patteri, P; Pavel, T; Pavlovich, J; Payne, D J; Peak, L S; Peimer, D R; Pelizaeus, M; Pellegrini, R; Pelliccioni, M; Peng, C C; Peng, J C; Peng, K C; Peng, T; Penichot, Y; Pennazzi, S; Pennington, M R; Penny, R C; Penzkofer, A; Perazzo, A; Perez, A; Perl, M; Pernicka, M; Perroud, J -P; Peruzzi, I M; Pestotnik, R; Peters, K; Peters, M; Petersen, B A; Petersen, T C; Petigura, E; Petrak, S; Petrella, A; Petrič, M; Petzold, A; Pia, M G; Piatenko, T; Piccolo, D; Piccolo, M; Piemontese, L; Piemontese, M; Pierini, M; Pierson, S; Pioppi, M; Piredda, G; Pivk, M; Plaszczynski, S; Polci, F; Pompili, A; Poropat, P; Posocco, M; Potter, C T; Potter, R J L; Prasad, V; Prebys, E; Prencipe, E; Prendki, J; Prepost, R; Prest, M; Prim, M; Pripstein, M; Prudent, X; Pruvot, S; Puccio, E M T; Purohit, M V; Qi, N D; Quinn, H; Raaf, J; Rabberman, R; Raffaelli, F; Ragghianti, G; Rahatlou, S; Rahimi, A M; Rahmat, R; Rakitin, A Y; Randle-Conde, A; Rankin, P; Rashevskaya, I; Ratkovsky, S; Raven, G; Re, V; Reep, M; Regensburger, J J; Reidy, J; Reif, R; Reisert, B; Renard, C; Renga, F; Ricciardi, S; Richman, J D; Ritchie, J L; Ritter, M; Rivetta, C; Rizzo, G; Roat, C; Robbe, P; Roberts, D A; Robertson, A I; Robutti, E; Rodier, S; Rodriguez, D M; Rodriguez, J L; Rodriguez, R; Roe, N A; Röhrken, M; Roethel, W; Rolquin, J; Romanov, L; Romosan, A; Ronan, M T; Rong, G; Ronga, F J; Roos, L; Root, N; Rosen, M; Rosenberg, E I; Rossi, A; Rostomyan, A; Rotondo, M; Roussot, E; Roy, J; Rozanska, M; Rozen, Y; Rubin, A E; Ruddick, W O; Ruland, A M; Rybicki, K; Ryd, A; Ryu, S; Ryuko, J; Sabik, S; Sacco, R; Saeed, M A; Tehrani, F Safai; Sagawa, H; Sahoo, H; Sahu, S; Saigo, M; Saito, T; Saitoh, S; Sakai, K; Sakamoto, H; Sakaue, H; Saleem, M; Salnikov, A A; Salvati, E; Salvatore, F; Samuel, A; Sanders, D A; Sanders, P; Sandilya, S; Sandrelli, F; Sands, W; Sands, W R; Sanpei, M; Santel, D; Santelj, L; Santoro, V; Santroni, A; Sanuki, T; Sarangi, T R; Saremi, S; Sarti, A; Sasaki, T; Sasao, N; Satapathy, M; Sato, Nobuhiko; Sato, Noriaki; Sato, Y; Satoyama, N; Satpathy, A; Savinov, V; Savvas, N; Saxton, O H; Sayeed, K; Schaffner, S F; Schalk, T; Schenk, S; Schieck, J R; Schietinger, T; Schilling, C J; Schindler, R H; Schmid, S; Schmitz, R E; Schmuecker, H; Schneider, O; Schnell, G; Schönmeier, P; Schofield, K C; Schott, G; Schröder, H; Schram, M; Schubert, J; Schümann, J; Schultz, J; Schumm, B A; Schune, M H; Schwanke, U; Schwarz, H; Schwiening, J; Schwierz, R; Schwitters, R F; Sciacca, C; Sciolla, G; Scott, I J; Seeman, J; Seiden, A; Seitz, R; Seki, T; Sekiya, A I; Semenov, S; Semmler, D; Sen, S; Senyo, K; Seon, O; Serbo, V V; Serednyakov, S I; Serfass, B; Serra, M; Serrano, J; Settai, Y; Seuster, R; Sevior, M E; Shakhova, K V; Shang, L; Shapkin, M; Sharma, V; Shebalin, V; Shelkov, V G; Shen, B C; Shen, D Z; Shen, Y T; Sherwood, D J; Shibata, T; Shibata, T A; Shibuya, H; Shidara, T; Shimada, K; Shimoyama, M; Shinomiya, S; Shiu, J G; Shorthouse, H W; Shpilinskaya, L I; Sibidanov, A; Sicard, E; Sidorov, A; Sidorov, V; Siegle, V; Sigamani, M; Simani, M C; Simard, M; Simi, G; Simon, F; Simonetto, F; Sinev, N B; Singh, H; Singh, J B; Sinha, R; Sitt, S; Skovpen, Yu I; Sloane, R J; Smerkol, P; Smith, A J S; Smith, D; Smith, D S; Smith, J G; Smol, A; Snoek, H L; Snyder, A; So, R Y; Sobie, R J; Soderstrom, E; Soha, A; Sohn, Y S; Sokoloff, M D; Sokolov, A; Solagna, P; Solovieva, E; Soni, N; Sonnek, P; Sordini, V; Spaan, B; Spanier, S M; Spencer, E; Speziali, V; Spitznagel, M; Spradlin, P; Staengle, H; Stamen, R; Stanek, M; Stanič, S; Stark, J; Steder, M; Steininger, H; Steinke, M; Stelzer, J; Stevanato, E; Stocchi, A; Stock, R; Stoeck, H; Stoker, D P; Stroili, R; Strom, D; Strother, P; Strube, J; Stugu, B; Stypula, J; Su, D; Suda, R; Sugahara, R; Sugi, A; Sugimura, T; Sugiyama, A; Suitoh, S; Sullivan, M K; Sumihama, M; Sumiyoshi, T; Summers, D J; Sun, L; Sun, S; Sundermann, J E; Sung, H F; Susaki, Y; Sutcliffe, P; Suzuki, A; Suzuki, J; Suzuki, J I; Suzuki, K; Suzuki, S; Suzuki, S Y; Swain, J E; Swain, S K; T'Jampens, S; Tabata, M; Tackmann, K; Tajima, H; Tajima, O; Takahashi, K; Takahashi, S; Takahashi, T; Takasaki, F; Takayama, T; Takita, M; Tamai, K; Tamponi, U; Tamura, N; Tan, N; Tan, P; Tanabe, K; Tanabe, T; Tanaka, H A; Tanaka, J; Tanaka, M; Tanaka, S; Tanaka, Y; Tanida, K; Taniguchi, N; Taras, P; Tasneem, N; Tatishvili, G; Tatomi, T; Tawada, M; Taylor, F; Taylor, G N; Taylor, G P; Telnov, V I; Teodorescu, L; Ter-Antonyan, R; Teramoto, Y; Teytelman, D; Thérin, G; Thiebaux, Ch; Thiessen, D; Thomas, E W; Thompson, J M; Thorne, F; Tian, X C; Tibbetts, M; Tikhomirov, I; Tinslay, J S; Tiozzo, G; Tisserand, V; Tocut, V; Toki, W H; Tomassini, E W; Tomoto, M; Tomura, T; Torassa, E; Torrence, E; Tosi, S; Touramanis, C; Toussaint, J C; Tovey, S N; Trapani, P P; Treadwell, E; Triggiani, G; Trincaz-Duvoid, S; Trischuk, W; Troost, D; Trunov, A; Tsai, K L; Tsai, Y T; Tsujita, Y; Tsukada, K; Tsukamoto, T; Tuggle, J M; Tumanov, A; Tung, Y W; Turnbull, L; Turner, J; Turri, M; Uchida, K; Uchida, M; Uchida, Y; Ueki, M; Ueno, K; Ujiie, N; Ulmer, K A; Unno, Y; Urquijo, P; Ushiroda, Y; Usov, Y; Usseglio, M; Usuki, Y; Uwer, U; Va'vra, J; Vahsen, S E; Vaitsas, G; Valassi, A; Vallazza, E; Vallereau, A; Vanhoefer, P; van Hoek, W C; Van Hulse, C; van Winkle, D; Varner, G; Varnes, E W; Varvell, K E; Vasileiadis, G; Velikzhanin, Y S; Verderi, M; Versillé, S; Vervink, K; Viaud, B; Vidal, P B; Villa, S; Villanueva-Perez, P; Vinograd, E L; Vitale, L; Vitug, G M; Voß, C; Voci, C; Voena, C; Volk, A; von Wimmersperg-Toeller, J H; Vorobyev, V; Vossen, A; Vuagnin, G; Vuosalo, C O; Wacker, K; Wagner, A P; Wagner, D L; Wagner, G; Wagner, M N; Wagner, S R; Wagoner, D E; Walker, D; Walkowiak, W; Wallom, D; Wang, C C; Wang, C H; Wang, J; Wang, J G; Wang, K; Wang, L; Wang, L L; Wang, P; Wang, T J; Wang, W F; Wang, X L; Wang, Y F; Wappler, F R; Watanabe, M; Watson, A T; Watson, J E; Watson, N K; Watt, M; Weatherall, J H; Weaver, M; Weber, T; Wedd, R; Wei, J T; Weidemann, A W; W, A J R; Wenzel, W A; West, C A; West, C G; West, T J; White, R M; Wicht, J; Widhalm, L; Wiechczynski, J; Wienands, U; Wilden, L; Wilder, M; Williams, D C; Williams, G; Williams, J C; Williams, K M; Williams, M I; Willocq, S Y; Wilson, J R; Wilson, M G; Wilson, R J; Winklmeier, F; Winter, M A; Wisniewski, W J; Wittgen, M; Wittlin, J; Wittmer, W; Wixted, R; Woch, A; Wogsland, B J; Wong, Q K; Wray, B C; Wren, A C; Wright, D M; Wu, C H; Wu, J; Wu, S L; Wulsin, H W; Xella, S M; Xie, Q L; Xie, Y; Xu, Z Z; Yèche, Ch; Yamada, Y; Yamaga, M; Yamaguchi, A; Yamaguchi, H; Yamaki, T; Yamamoto, H; Yamamoto, N; Yamamoto, R K; Yamamoto, S; Yamanaka, T; Yamaoka, H; Yamaoka, J; Yamaoka, Y; Yamashita, Y; Yamauchi, M; Yan, D S; Yan, Y; Yanai, H; Yanaka, S; Yang, H; Yang, R; Yang, S; Yarritu, A K; Yashchenko, S; Yashima, J; Yasin, Z; Yasu, Y; Ye, S W; Yeh, P; Yi, J I; Yi, K; Yi, M; Yin, Z W; Ying, J; Yocky, G; Yokoyama, K; Yokoyama, M; Yokoyama, T; Yoshida, K; Yoshida, M; Yoshimura, Y; Young, C C; Yu, C X; Yu, Z; Yuan, C Z; Yuan, Y; Yumiceva, F X; Yusa, Y; Yushkov, A N; Yuta, H; Zacek, V; Zain, S B; Zallo, A; Zambito, S; Zander, D; Zang, S L; Zanin, D; Zaslavsky, B G; Zeng, Q L; Zghiche, A; Zhang, B; Zhang, J; Zhang, L; Zhang, L M; Zhang, S Q; Zhang, Z P; Zhao, H W; Zhao, M; Zhao, Z G; Zheng, Y; Zheng, Y H; Zheng, Z P; Zhilich, V; Zhou, P; Zhu, R Y; Zhu, Y S; Zhu, Z M; Zhulanov, V; Ziegler, T; Ziegler, V; Zioulas, G; Zisman, M; Zito, M; Zürcher, D; Zwahlen, N; Zyukova, O; Živko, T; Žontar, D; Bevan, Adrian; Golob, Bostjan; Mannel, Thomas; Prell, Soeren; Yabsley, Bruce

    2014-01-01

    This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.

  15. Alternativas de análises em dados de medidas repetidas de bovinos de corte Alternative analyses of repeated weight measurements of beef cattle

    Directory of Open Access Journals (Sweden)

    Alfredo Ribeiro de Freitas

    2005-12-01

    Full Text Available Objetivou-se estudar duas alternativas de análises de variâncias e covariâncias para dados de pesagens de bovinos. Foram utilizados dados de animais Nelore, Guzerá, Gir e Indubrasil, machos e fêmeas, pertencentes à Associação Brasileira de Criadores de Zebu - ABCZ. De cada indivíduo, foram obtidas, em intervalos trimestrais, nove medidas repetidas de pesos, do nascimento aos dois anos de idade. Na primeira análise, a variável resposta y i foi transformada por meio da família de transformação de Box-Cox y ilambda = (ylambda-lambda/lambda, (l ¹ 0 ou y i = log y i, (lambda = 0. Essa transformação foi efetiva na redução dos coeficientes de assimetria e da heterogeneidade de variância para todas as pesagens e raças. Na segunda análise, foi selecionada a estrutura de covariâncias mais adequada para representar a variabilidade dentro de indivíduo, considerando-se um modelo misto usual para medidas repetidas. Utilizando-se os critérios fornecidos pelo procedimento MIXED do SAS: distribuição de chi2, AIC ("Akaike's Information Criterion" e SBC ("Schwarz's Bayesian Criterion", a estrutura de covariância mais adequada para todas as raças foi a Não-Estruturada, seguida da estrutura Fator-Analítico para Nelore, Gir e Indubrasil e Simetria Composta Heterogênea para Guzerá.Data consisting of individual records of male and female animals of purebred Bos Indicus beef cattle (Nellore, Guzerá, Gir and Indubrasil weighted every three months from birth to 24 months of age available from National Archive of Brazilian Zebu Breeders Association (ABCZ were used to evaluate two alternatives (covariance analyses for body weight. In the first analysis the Box-Cox family transformation y ilambda = (ylambda-lambda/lambda (l ¹ 0 or y i = log y i, for lambda=0 was effective in reducing the asymmetry of the coefficients and variance heterogeneity for all weights and breeds. In the second analysis a usual standard mixed model for repeated

  16. The Experience Factory: Strategy and Practice

    Science.gov (United States)

    Basili, Victor R.; Caldiera, Gianluigi

    1995-01-01

    The quality movement, that has had in recent years a dramatic impact on all industrial sectors, has recently reached the system and software industry. Although some concepts of quality management, originally developed for other product types, can be applied to software, its specificity as a product which is developed and not produced requires a special approach. This paper introduces a quality paradigm specifically tailored on the problem of the systems and software industry. Reuse of products, processes and experiences originating from the system life cycle is seen today as a feasible solution to the problem of developing higher quality systems at a lower cost. In fact, quality improvement is very often achieved by defining and developing an appropriate set of strategic capabilities and core competencies to support them. A strategic capability is, in this context, a corporate goal defined by the business position of the organization and implemented by key business processes. Strategic capabilities are supported by core competencies, which are aggregate technologies tailored to the specific needs of the organization in performing the needed business processes. Core competencies are non-transitional, have a consistent evolution, and are typically fueled by multiple technologies. Their selection and development requires commitment, investment and leadership. The paradigm introduced in this paper for developing core competencies is the Quality Improvement Paradigm which consists of six steps: (1) Characterize the environment, (2) Set the goals, (3) Choose the process, (4) Execute the process, (5) Analyze the process data, and (6) Package experience. The process must be supported by a goal oriented approach to measurement and control, and an organizational infrastructure, called Experience Factory. The Experience Factory is a logical and physical organization distinct from the project organizations it supports. Its goal is development and support of core competencies

  17. The factorial structure of pathological gambling.

    Science.gov (United States)

    Steel, Z; Blaszczynski, A

    1996-03-01

    Pathological gambling has been characterised by DSM-III-R and DSM-IV as a disorder of impulse control with a proportion of gamblers identified as meeting criteria for a co-morbid diagnosis of Antisocial Personality Disorder. To date, empirical evidence in support of the notion that pathological gamblers as a group manifest elevated traits of impulsivity remains equivocal. Principal components analysis was used to investigate relationships between the constructs of impulsivity, psychopathy, DSM-III-R criteria for Antisocial Personality Disorder, psychological distress, criminal offending behavior and a range of other common psychological measures employed with pathological gamblers. The sample comprised 115 pathological gamblers, 80 consecutive gamblers seeking treatment from a general hospital psychiatric inpatient behavior therapy unit, and 35 volunteer Gamblers Anonymous attenders. Four primary factors were determined: psychological distress, sensation seeking, crime and liveliness, and impulsive-antisocial. Results suggest that pathological gambling consists of a number of discrete and reproducible factorial structures. The impulsive antisocial factor was found to be associated with gambling behavior and indices of poor psychosocial functioning.

  18. New Physics at a Super Flavor Factory

    CERN Document Server

    Browder, Thomas E; Pirjol, Dan; Soni, Amarjit; Zupan, Jure

    2009-01-01

    The potential of a Super Flavor Factory (SFF) for searches of New Physics is reviewed. While very high luminosity B physics is assumed to be at the core of the program, its scope for extensive charm and tau studies are also emphasized. The possibility to run at the Upsilon(5S) as well as at the Upsilon(4S) is also very briefly discussed; in principle, this could provide very clean measurements of B_s decays. The strength and reach of a SFF is most notably due to the possibility of examining an impressive array of very clean observables. The angles and the sides of the unitarity triangle can be determined with unprecedented accuracy. These serve as a reference for New Physics (NP) sensitive decays such as B^+ ->tau^+ nu and penguin dominated hadronic decay modes, providing tests of generic NP scenarios with an accuracy of a few percent. Besides, very precise studies of direct and time dependent CP asymmetries in radiative B decays and forward-backward asymmetry studies in B -> X_s l^+ l^- and numerous null tes...

  19. Shielding design of RIKEN RI Beam Factory

    Energy Technology Data Exchange (ETDEWEB)

    Uwamino, Yoshitomo; Fukunishi, Nobuhisa [Institute of Physical and Chemical Research, Wako, Saitama (Japan); Oishi, Koji [Shimizu Corp., Tokyo (Japan)

    2000-03-01

    Construction of the RIKEN RI Beam Factory is started, and the phase 1 will be finished by the end of March 2003. Two ring cyclotrons including one superconducting machine and two Big RIPSs will be constructed in the phase 1. Heavy ions of proton to uranium will be accelerated up to 400 MeV/u (A<40) and 150 MeV/u for uranium at an intensity of 10{sup 13} pps. Neutron production by the 400 MeV/u {sup 20}Ne beam was measured at HIMAC of NIRS and it was used for the source term of the shielding calculations. The deep penetration of high-energy neutrons was calculated by using the ANISN code with the DLC-119/HILO86R group constants and also by using the HETC code. The ANISN results were modified by using the HETC results and the shielding experiment at ISIS, and they were fitted by a simple formula for practical use. High-energy neutron penetrations of slantwise injection and the reflection probabilities of iron slab were calculated with the HETC code, and these results were used for the estimation of the thickness for the iron local shielding of Big RIPSs. Induced radioactivity in the air, accelerator components and the building, and the skyshine effect were also estimated. (author)

  20. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  1. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  2. A large magnetic detector for the neutrino factory

    International Nuclear Information System (INIS)

    Cervera, A.; Dydak, F.; Gomez Cadenas, J.J.

    2000-01-01

    The physics opportunities of the neutrino factory have been the subject of a number of recent studies. It was shown that sensitive measurements of the angle θ 13 , of MSW effects, and of the sign of the atmospheric mass difference Δm 23 2 are possible, and even CP violation in the neutrino mixing matrix may be within reach. The focus of interest is the oscillation ν e →ν μ , which leads in the well-defined neutrino beam of the neutrino factory to 'wrong-sign' muon events. In this paper, we show that a large magnetic detector will be capable of detecting with high efficiency and small backgrounds such wrong-sign muon events. We present a conceptual design of the apparatus and its performance. Various backgrounds are analysed and we demonstrate that they can be sufficiently suppressed by appropriate cuts. We illustrate the performance of the large magnetic detector by its sensitivity to the angle θ 13

  3. SEARCH FOR NEW PHYSICS AT A SUPER-B FACTORY.

    Energy Technology Data Exchange (ETDEWEB)

    BROWDER,T.E.; SONI,A.

    2004-01-05

    The importance of a Super-B Factory in the search for New Physics, in particular, due to CP-od phase(s) from physics beyond the Standard Model is surveyed. The first point to emphasize is that we know now how to directly measure all three angles of the unitarity triangle very cleanly, i. e. without theoretical assumptions with irreducible theory error {le} 1%; however this requires much more luminosity than is currently available at B-factories. Direct searches via penguin-dominated hadronic modes as well as radiative, pair-leptonic and semi-leptonic decays are also discussed. Null tests of the SM are stressed as these will play a crucial role especially if the effects of BSM phase(s) on B-physics are small.

  4. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  5. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    Science.gov (United States)

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  6. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  7. Repeated cycles of chemical and physical disinfection and their influence on Mycobacterium avium subsp. paratuberculosis viability measured by propidium monoazide F57 quantitative real time PCR.

    Science.gov (United States)

    Kralik, Petr; Babak, Vladimir; Dziedzinska, Radka

    2014-09-01

    Mycobacterium avium subsp. paratuberculosis (MAP) has a high degree of resistance to chemical and physical procedures frequently used for the elimination of other bacteria. Recently, a method for the determination of viability by exposure of MAP to propidium monoazide (PMA) and subsequent real time quantitative PCR (qPCR) was established and found to be comparable with culture. The aim of this study was to apply the PMA qPCR method to determine the impact of increasing concentration or time and repeated cycles of the application of selected disinfectants on MAP viability. Different MAP isolates responded to the same type of stress in different ways. The laboratory strain CAPM 6381 had the highest tolerance, while the 8819 low-passage field isolate was the most sensitive. Ultraviolet exposure caused only a partial reduction in MAP viability; all MAP isolates were relatively resistant to chlorine. Only the application of peracetic acid led to the total elimination of MAP. Repeated application of the treatments resulted in more significant decreases in MAP viability compared to single increases in the concentration or time of exposure to the disinfectant. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Quantum repeated games revisited

    International Nuclear Information System (INIS)

    Frąckiewicz, Piotr

    2012-01-01

    We present a scheme for playing quantum repeated 2 × 2 games based on Marinatto and Weber’s approach to quantum games. As a potential application, we study the twice repeated Prisoner’s Dilemma game. We show that results not available in the classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games proposed by Iqbal and Toor. We point out the drawbacks that make their results unacceptable. (paper)

  9. Pharmacokinetics of taurolidine following repeated intravenous infusions measured by HPLC-ESI-MS/MS of the derivatives taurultame and taurinamide in glioblastoma patients.

    Science.gov (United States)

    Stendel, Ruediger; Scheurer, Louis; Schlatterer, Kathrin; Stalder, Urs; Pfirrmann, Rolf W; Fiss, Ingo; Möhler, Hanns; Bigler, Laurent

    2007-01-01

    Taurolidine is known to have antimicrobial activity. Furthermore, at lower concentrations, it has been found to exert a selective antineoplastic effect in vitro and in vivo. The aim of this study was to investigate the pharmacokinetics of taurolidine in vivo following repeated intravenous infusion in a schedule used for the treatment of glioblastoma. As a prerequisite, the pharmacokinetics of taurolidine in human blood plasma and whole blood in vitro was investigated. The pharmacokinetics of taurolidine and its derivatives taurultame and taurinamide were investigated in human blood plasma and in whole blood in vitro using blood from a healthy male volunteer. During repeated intravenous infusion therapy with taurolidine, plasma samples were taken every hour for a period of 13 hours per day in seven patients (three male, four female; mean age 48.4 +/- 12.8 years, range 27-66 years) with a glioblastoma. Following dansyl derivatisation, the concentrations of taurultame and taurinamide were determined using a new method based on high-performance liquid chromatography (HPLC) online coupled to electrospray ionisation tandem mass spectrometry (ESI-MS/MS) in the multiple reaction monitoring mode. Under the experimental conditions used, taurolidine could not be determined directly and was back-calculated from the taurultame and taurinamide values. The new HPLC-ESI-MS/MS method demonstrated high accuracy and reproducibility. In vitro plasma concentrations of taurultame and taurinamide remained constant over the incubation period. In whole blood in vitro, a time-dependent formation of taurinamide was observed. At the start of the incubation, the taurultame-taurinamide ratio (TTR) was 0.95 at an initial taurolidine concentration of 50 microg/mL, and 1.69 at 100 microg/mL. The concentration of taurultame decreased at the same rate as the taurinamide concentration increased, showing logarithmic kinetics. The calculated taurolidine concentration remained largely constant over the

  10. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  11. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  12. Survey of the respiratory health of the workers of a talc producing factory.

    OpenAIRE

    Wild, P; Réfrégier, M; Auburtin, G; Carton, B; Moulin, J J

    1995-01-01

    OBJECTIVES--To assess the effect of an occupational exposure to talc dust on respiratory health. METHODS--166 talc millers from a French factory underwent spirometry and filled in a standardised respiratory questionnaire during their annual medical visit in 1989. A full sized chest radiograph taken in 1987 for the subjects hired before 1982 was also available, for the others a radiograph taken when hired was used. Radiography was repeated in 1992 for all subjects still active at this date (n ...

  13. Factorials of real negative and imaginary numbers - A new perspective.

    Science.gov (United States)

    Thukral, Ashwani K

    2014-01-01

    Presently, factorials of real negative numbers and imaginary numbers, except for zero and negative integers are interpolated using the Euler's gamma function. In the present paper, the concept of factorials has been generalised as applicable to real and imaginary numbers, and multifactorials. New functions based on Euler's factorial function have been proposed for the factorials of real negative and imaginary numbers. As per the present concept, the factorials of real negative numbers, are complex numbers. The factorials of real negative integers have their imaginary part equal to zero, thus are real numbers. Similarly, the factorials of imaginary numbers are complex numbers. The moduli of the complex factorials of real negative numbers, and imaginary numbers are equal to their respective real positive number factorials. Fractional factorials and multifactorials have been defined in a new perspective. The proposed concept has also been extended to Euler's gamma function for real negative numbers and imaginary numbers, and beta function.

  14. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  15. Modelo de Cuadro de Mando para una Software Factory del Sector Financiero

    OpenAIRE

    Álvarez Pérez, César

    2012-01-01

    Abstract This work aims to search for KPI’s, Key Performance Indicators which permit to measure productivity of the generation of Financial Software in a Software Factory, which means the workplace where software is developed by using principles and techniques associated to traditional industrial production. A set of new indicators is presented, which together with the already used and more traditional ones, allow us to assess productivity and performance for Software Factory. The ...

  16. Prevalence of hearing loss and accuracy of self-report among factory workers

    OpenAIRE

    Marjorie C McCullagh; Delbert Raymond; Madeleine J Kerr; Sally L Lusk

    2011-01-01

    Noise represents one of the most common occupational health hazards. A Healthy People 2020 objective aims to reduce hearing loss in the noise-exposed public. The purpose of this study was to describe and compare perceived and measured hearing, and to determine the prevalence of hearing loss among a group of factory workers. Data collected as part of an intervention study promoting hearing protector use among workers at an automotive factory in the Midwest were used. Plant employees (n=2691) p...

  17. Analysis of scaled-factorial-moment data

    International Nuclear Information System (INIS)

    Seibert, D.

    1990-01-01

    We discuss the two standard constructions used in the search for intermittency, the exclusive and inclusive scaled factorial moments. We propose the use of a new scaled factorial moment that reduces to the exclusive moment in the appropriate limit and is free of undesirable multiplicity correlations that are contained in the inclusive moment. We show that there are some similarities among most of the models that have been proposed to explain factorial-moment data, and that these similarities can be used to increase the efficiency of testing these models. We begin by calculating factorial moments from a simple independent-cluster model that assumes only approximate boost invariance of the cluster rapidity distribution and an approximate relation among the moments of the cluster multiplicity distribution. We find two scaling laws that are essentially model independent. The first scaling law relates the moments to each other with a simple formula, indicating that the different factorial moments are not independent. The second scaling law relates samples with different rapidity densities. We find evidence for much larger clusters in heavy-ion data than in light-ion data, indicating possible spatial intermittency in the heavy-ion events

  18. Baby factories taint surrogacy in Nigeria.

    Science.gov (United States)

    Makinde, Olusesan Ayodeji; Makinde, Olufunmbi Olukemi; Olaleye, Olalekan; Brown, Brandon; Odimegwu, Clifford O

    2016-01-01

    The practice of reproductive medicine in Nigeria is facing new challenges with the proliferation of 'baby factories'. Baby factories are buildings, hospitals or orphanages that have been converted into places for young girls and women to give birth to children for sale on the black market, often to infertile couples, or into trafficking rings. This practice illegally provides outcomes (children) similar to surrogacy. While surrogacy has not been well accepted in this environment, the proliferation of baby factories further threatens its acceptance. The involvement of medical and allied health workers in the operation of baby factories raises ethical concerns. The lack of a properly defined legal framework and code of practice for surrogacy makes it difficult to prosecute baby factory owners, especially when they are health workers claiming to be providing services to clients. In this environment, surrogacy and other assisted reproductive techniques urgently require regulation in order to define when ethico-legal lines have been crossed in providing surrogacy or surrogacy-like services. Copyright © 2015 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  19. Repeat migration and disappointment.

    Science.gov (United States)

    Grant, E K; Vanderkamp, J

    1986-01-01

    This article investigates the determinants of repeat migration among the 44 regions of Canada, using information from a large micro-database which spans the period 1968 to 1971. The explanation of repeat migration probabilities is a difficult task, and this attempt is only partly successful. May of the explanatory variables are not significant, and the overall explanatory power of the equations is not high. In the area of personal characteristics, the variables related to age, sex, and marital status are generally significant and with expected signs. The distance variable has a strongly positive effect on onward move probabilities. Variables related to prior migration experience have an important impact that differs between return and onward probabilities. In particular, the occurrence of prior moves has a striking effect on the probability of onward migration. The variable representing disappointment, or relative success of the initial move, plays a significant role in explaining repeat migration probabilities. The disappointment variable represents the ratio of actural versus expected wage income in the year after the initial move, and its effect on both repeat migration probabilities is always negative and almost always highly significant. The repeat probabilities diminish after a year's stay in the destination region, but disappointment in the most recent year still has a bearing on the delayed repeat probabilities. While the quantitative impact of the disappointment variable is not large, it is difficult to draw comparisons since similar estimates are not available elsewhere.

  20. Pseudomonas putida as a microbial cell factory

    DEFF Research Database (Denmark)

    Wigneswaran, Vinoth

    for sustainable production of chemicals, which can be achieved by microbial cell factories. The work presented in this PhD thesis elucidates the application of Pseudomonas putida as a microbial cell factory for production of the biosurfactant rhamnolipid. The rhamnolipid production was achieved by heterologous...... phase. The genomic alterations were identified by genome sequencing and revealed parallel evolution. Glycerol was also shown to be able to support biofilm growth and as a result of this it can be used as an alternative substrate for producing biochemicals in conventional and biofilm reactors. The use...... of biofilm as a production platform and the usage of glycerol as a feedstock show the potential of using microbial cell factories in the transition toward sustainable production of chemicals. Particularly, the applicability of biofilm as a production platform can emerge as a promising alternative...

  1. Ergonomic analysis jobs in recovered factories.

    Science.gov (United States)

    Cuenca, Gabriela; Zotta, Gastón

    2012-01-01

    With the advent of the deep economic crisis in Argentina on 2001, the recovery of companies through to the creation of the Cooperatives Working Self-Management or Factories Recovered by its workers was constituted as one of the ways in which the salaried disobeyed the increasing unemployment. When the companies turn into recovered factories they tend to leave of side practices that have been seen like imposed by the previous organization and not understanding them as a primary condition for the execution of his tasks. Safety and ergonomics are two disciplines that are no longer considered relevant to the daily work. Therefore this investigation aims to revalue, undergo semantic to give back to a place in every organization analyzed. This research developed a self-diagnostic tool for working conditions, and the environment, present in the recovered factories.

  2. A conceptual design of circular Higgs factory

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yunhai

    2016-11-30

    Similar to a super B-factory, a circular Higgs factory (CHF) will require strong focusing systems near the interaction points and a low-emittance lattice in the arcs to achieve a factory luminosity. At electron beam energy of 125 GeV, beamstrahlung effects during the collision pose an additional challenge to the collider design. In particular, a large momentum acceptance at the 2% level is necessary to retain an adequate beam lifetime. This turns out to be the most challenging aspect in the design of a CHF. In this paper, an example will be provided to illustrate the beam dynamics in a CHF, emphasizing the chromatic optics. Basic optical modules and advanced analysis will be presented. Most importantly, we will show that 2% momentum aperture is achievable.

  3. Optimized Neutrino Factory for small and large θ13

    International Nuclear Information System (INIS)

    Agarwalla, Sanjib Kumar

    2013-01-01

    Recent results from long baseline neutrino oscillation experiments point towards a non-zero value of θ 13 at around 3σ confidence level. In the coming years, further ratification of this result with high significance will have crucial impact on the planning of the future long baseline Neutrino Factory setup aimed to explore leptonic CP violation and the neutrino mass ordering. In this talk, we discuss the baseline and energy optimization of the Neutrino Factory including the latest simulation results on the magnetized iron neutrino detector (MIND) in the light of both small and large θ 13 . We find that in case of small θ 13 , baselines of about 2500 to 5000 km is the optimal choice for the CP violation measurement with E μ as low as 12 GeV can be considered. However, for large θ 13 , we show that the lower threshold and the backgrounds reconstructed at lower energies allow in fact for muon energies as low as 5 to 8 GeV at considerably shorter baselines, such as Fermilab to Homestake. This suggests that with the latest MIND simulation, low- and high-energy versions of the Neutrino Factory are just two different forms of the same experiment optimized for different regions of the parameter space.

  4. Advanced factory managing technology. Sentan kojo kanri gijuts

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, M [Daicel Chemical Industries, Ltd., Osaka (Japan)

    1994-04-05

    With respect to a managing technology of advanced factories in the Japanese chemical industry, this paper enumerates the following three examples to discuss the ways the future factory technologies should be: operation techniques and problems in a newest ethylene plant, operation supports and facility control in chemical factories, and CIM structuring in beer breweries. The paper describes the operation techniques in an ethylene plant that are broken down into the following: measures for safety and material diversification, environment preservation, means to minimize the required labor, adoption of multi-variables, non-interference control technology for ethylene-propylene columns, and operation techniques that have been introduced with such a new technique as an integrated instrumentation room equipped with a gas leakage detection system. Structuring of CIM in the cited beer brewery has followed the transition of IE-TQC-JIT-FMS-CIM. Although a beer brewery may give somewhat different image from an ordinary chemical plant, the beer brewing process resembles a chemical plant in that it operates reacting machines in batch multiple tanks, and uses instrumentations and controllers using sensors. The key point in the future development is an organic link between market fluctuation and production activities. 1 fig.

  5. Pulmonary functions in plastic factory workers: a preliminary study.

    Science.gov (United States)

    Khaliq, Farah; Singh, Pawan; Chandra, Prakash; Gupta, Keshav; Vaney, Neelam

    2011-01-01

    Exposure to long term air pollution in the work environment may result in decreased lung functions and various other health problems. A significant occupational hazard to lung functions is experienced by plastic factory workers. The present study is planned to assess the pulmonary functions of workers in the plastic factory where recycling of pastic material was done. These workers were constantly exposed to fumes of various chemicals throughout the day. Thirty one workers of plastic factory were assessed for their pulmonary functions. Parameters were compared with 31 age and sex matched controls not exposed to the same environment. The pulmonary function tests were done using Sibelmed Datospir 120 B portable spirometer. A significant decrease in most of the flow rates (MEF 25%, MEF 50%, MEF 75% and FEF 25-75%) and most of the lung volumes and capacities (FVC, FEV1, VC, TV, ERV, MVV) were observed in the workers. Smoking and duration of exposure were not affecting the lung functions as the non smokers also showed a similar decrement in pulmonary functions. Similarly the workers working for less than 5 years also had decrement in pulmonary functions indicating that their lungs are being affected even if they have worked for one year. Exposure to the organic dust in the work environment should be controlled by adequate engineering measures, complemented by effective personal respiratory protection.

  6. Synchrotron radiation leakage from the B-factory beam pipe

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Nelson, W.R.; Ipe, N.

    1990-01-01

    The high-energy ring (HER) of the B-Factory, running at an energy of 9 GeV, generates the synchrotron spectrum when applied to a ring with the PEP bending radius. The B-Factory HER may also run at 12 GeV, producing the harder spectrum. Depending upon beam-pipe material and thickness, some of this radiation may escape and deposit energy in the surrounding material. This was originally pointed out in PEP-109 during the initial design of PEP, and subsequently verified by measurements at both PEP and PETRA at DESY. Of concern to the B Factory is magnet insulation, though other adjacent materials such as wire insulation and cooling water hoses are even more radiosensitive. Radiation damage to magnets is a function of the type of material used in the potting compound. The PEP magnets, which hopefully can be used for the high-energy ring of the B-Factory, are insulated with an epoxy composed of DER-332, DER-732, NMA and aluminum oxide. It is estimated that this epoxy compound should tolerate doses near the 10 10 rad range. To summarize the results of these calculations, 0.87 cm of copper is needed at the point of maximum dose from 12-GeV operation in order to reach the dose criterion if a rectangular beam pipe is used. The copper needs to be only 0.7-cm thick for an octagonal beam pipe and the same energy. For 9-GeV operation, an octagonal copper pipe needs only to be 0.25-cm thick. An octagonal aluminum pipe that is 0.5-cm thick also needs 0.3 cm of lead on the outside to reach the same criterion for 12-GeV operation. For 9-GeV operation, the aluminum pipe still requires a lead liner

  7. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  8. Nuclear physics at the KAON factory

    International Nuclear Information System (INIS)

    Kitching, R.

    1989-05-01

    The author surveys the range of nuclear physics issues which can be addressed with a high intensity hadron facility such as the KAON factory. He discusses hadron spectroscopy, kaon scattering, hypernuclear physics, spin physics, and nuclear physics with neutrinos. Nuclear Physics is defined rather broadly, encompassing the study of strongly interacting systems, and including the structure of individual hadrons, hadron-hadron interactions, hadronic weak and electromagnetic currents (in nuclei too), conventional nuclear structure, and exotic nuclei. The basic theme is how the KAON Factory can shed light on non-perturbative QCD and its relation to conventional nuclear physics

  9. Interaction region considerations for a B-factory

    International Nuclear Information System (INIS)

    DeStaebler, H.

    1990-07-01

    The goal of the project is to observe CP violation in the bar BB system. This machine is supposed to be a factory for high energy physics, not an R ampersand D project for accelerator physics. There are a number of interrelated design issues arising from the different desires of the detector and the machine, some of which are listed in this paper. A number of background and beampipe issues are mentioned. The emphasis is on calculations. Any satisfactory design will combine measurements on existing machines with calculations pertaining to the measurement conditions as well as to the proposed machine. 57 refs

  10. Overview of the nearby supernova factory

    International Nuclear Information System (INIS)

    Aldering, Greg; Adam, Gilles; Antilogus, Pierre; Astier, Pierre; Bacon, Roland; Bongard, S.; Bonnaud, C.; Copin, Yannick; Hardin, D.; Howell, D. Andy; Lemmonnier, Jean-Pierre; Levy, J.-M.; Loken, S.; Nugent, Peter; Pain, Reynald; Pecontal, Arlette; Pecontal, Emmanuel; Perlmutter, Saul; Quimby, Robert; Schahmaneche, Kyan; Smadja, Gerard; Wood-Vasey, W. Michael

    2002-01-01

    The Nearby Supernova Factory (SNfactory) is an international experiment designed to lay the foundation for the next generation of cosmology experiments (such as CFHTLS, wP, SNAP and LSST) which will measure the expansion history of the Universe using Type Ia supernovae. The SNfactory will discover and obtain frequent lightcurve spectrophotometry covering 3200-10000 (angstrom) for roughly 300 Type Ia supernovae at the loW--redshift end of the smooth Hubble flow. The quantity, quality, breadth of galactic environments, and homogeneous nature of the SNfactory dataset will make it the premier source of calibration for the Type Ia supernova width-brightness relation and the intrinsic supernova colors used for K-correction and correction for extinction by host-galaxy dust. This dataset will also allow an extensive investigation of additional parameters which possibly influence the quality of Type Ia supernovae as cosmological probes. The SNfactory search capabilities and folloW--up instrumentation include wide-field CCD imagers on two 1.2-m telescopes (via collaboration with the Near Earth Asteroid Tracking team at JPL and the QUEST team at Yale), and a two-channel integral-field-unit optical spectrograph/imager being fabricated for the University of Hawaii 2.2-m telescope. In addition to ground-based folloW--up, UV spectra for a subsample of these supernovae will be obtained with HST. The pipeline to obtain, transfer via wireless and standard internet, and automatically process the search images is in operation. Software and hardware development is now underway to enable the execution of folloW--up spectroscopy of supernova candidates at the Hawaii 2.2-m telescope via automated remote control of the telescope and the IFU spectrograph/imager

  11. The Pentapeptide Repeat Proteins

    OpenAIRE

    Vetting, Matthew W.; Hegde, Subray S.; Fajardo, J. Eduardo; Fiser, Andras; Roderick, Steven L.; Takiff, Howard E.; Blanchard, John S.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S,T,A,V][D,N][L,F]-[S,T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Myc...

  12. BERKELEY/STANFORD: B factory plans

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    For the past several years, accelerator physicists at Lawrence Berkeley Laboratory (LBL) and the Stanford Linear Accelerator Center (SLAC) have been involved in the design of an Asymmetric B Factory to be sited in the tunnel of the PEP electron-positron collider at SLAC

  13. KEKB B-Factory, the luminosity frontier

    International Nuclear Information System (INIS)

    Oide, Katsunobu

    2009-01-01

    The experiment at the KEKB B-Factory, as well as PEP-II, brought the final blow on the 2008 Nobel Prize in Physics for the Kobayashi-Maskawa theory. A few key issues will be described on the design and performance of KEKB to make the world's highest luminosity possible. (author)

  14. The Energy Factory; EnergieFabriek

    Energy Technology Data Exchange (ETDEWEB)

    Van den Boomen, M.; Van den Dungen, G.J.; Elias, T.; Jansen, M. [Universiteit van Amsterdam UvA, Amsterdam (Netherlands)

    2009-05-15

    The Energy Factory is a collaboration of 26 Dutch local water boards in which options for energy saving and energy production are examined. According to the authors, the initiative of the Energy Factory will lead to a reframing of the role of the water boards. Moreover, they explain how the PPP concept (People, Planet, Profit) may act as platform for negotiations between actors who are involved in the Energy Factory. In addition, the PPP concept is used to demonstrate that the Energy Factory will lead to larger social involvement, social entrepreneurship and growing profits [Dutch] De Energiefabriek is een samenwerkingsverband van 26 waterschappen in Nederland waarin wordt gezocht naar mogelijkheden om energie te besparen en zelf energie te produceren. Volgens de auteurs van deze notitie leidt het initiatief van de Energiefabriek tot een reframing van de rol van waterschappen. Daarnaast leggen ze uit hoe het PPP-concept (People, Profit, Planet) kan fungeren als platform voor onderhandelingen tussen de actoren die betrokken zijn bij de Energiefabriek. Verder wordt met het PPP-concept aangetoond dat de Energiefabriek leidt tot ruimere maatschappelijke betrokkenheid, maatschappelijk ondernemen en winstvergroting.

  15. Racetrack lattices for the TRIUMF KAON factory

    International Nuclear Information System (INIS)

    Servranckx, R.V.; Wienands, U.; Craddock, M.K.; Rees, G.H.

    1989-03-01

    Separated-function racetrack lattices have been developed for the KAON Factory accelerators that have more flexibility than the old circular lattices. Straight sections with zero dispersion are provided for rf cavities and fast injection and extraction, and with controlled dispersion for H - injection and slow extraction. In addition the new lattices have fewer depolarizing resonances than the old circular lattices

  16. Factory automation for heavy electric equipment

    International Nuclear Information System (INIS)

    Rokutani, Takashi; Ninomiya, Iwao; Hatayama, Naokatsu; Kato, Hiroshi; Yano, Hideaki.

    1986-01-01

    The heightening of productivity in the factories manufacturing heavy electric equipment has been advanced so far by the rationalization of direct workings such as NC, robots and the adoption of FMS (flexible manufacturing system). However, as CAD advances, the effective utilization of these data and the expansion to future CIM (computer integrated manufacture) have become to be demanded. In the Hitachi Works of Hitachi Ltd., it was decided to advance the synthetic rationalization by adopting FA (factory automation) system. Steam turbine blades, pipings for nuclear power plants and motor coils were taken up as the objects since these are important parts, and for the purpose of the drastic heightening of QA level, the heightening of accuracy and the shortening of processes, the synchronization with field installation schedule and the creation of safe working place environment, the FA projects for these three sections were simultaneously planned. When the automation of non-mass production factories is promoted, there are the unmanned factories combining FMS lines for relatively many products and those characterized by FMC of shortening preparation time for small lot products, and this is the examples of the former. The system constitution for FA and the production management combined with it are described. The high reliability of the optical network was regarded as important. (Kako, I.)

  17. Employment and Training Problems in New Factories.

    Science.gov (United States)

    International Labour Office, Geneva (Switzerland).

    Does management in newly established factories using highly advanced technology meet special problems in recruitment and training of their workers? Are the traditional training systems supplying the skilled manpower required for running highly sophisticated plants? These were the basic questions asked when the present study was started in seven…

  18. The Mathematics of Symmetrical Factorial Designs

    Indian Academy of Sciences (India)

    The Mathematics of Symmetrical Factorial Designs. Mausumi Bose (nee Sen) obtained her MSc degree in. Statistics from the Calcutta. University and PhD degree from the Indian Statistical. Institute. She is on the faculty of the Indian. Statistical Institute. Her main field of research interest is design and analysis of experiments.

  19. A tau -- charm -- factory at Argonne

    International Nuclear Information System (INIS)

    Berger, E.; Fields, T.; Grosnick, D.; Norem, J.; Repond, J.; Schoessow, P.

    1994-01-01

    Depending on the beam energy setting, the τ -- charm -- factory will be optimized to study physics with τ leptons, with charmed mesons, or with charmonium states. This report gives a short overview of the physics of these topics. Also discussed are the detectors and the costs associated with this project

  20. Plant factories; crop transpiration and energy balance

    NARCIS (Netherlands)

    Graamans, Luuk; Dobbelsteen, van den Andy; Meinen, Esther; Stanghellini, Cecilia

    2017-01-01

    Population growth and rapid urbanisation may result in a shortage of food supplies for cities in the foreseeable future. Research on closed plant production systems, such as plant factories, has attempted to offer perspectives for robust (urban) agricultural systems. Insight into the explicit role

  1. Factorial and reduced K-means reconsidered

    NARCIS (Netherlands)

    Timmerman, Marieke E.; Ceulemans, Eva; Kiers, Henk A. L.; Vichi, Maurizio

    2010-01-01

    Factorial K-means analysis (FKM) and Reduced K-means analysis (RKM) are clustering methods that aim at simultaneously achieving a clustering of the objects and a dimension reduction of the variables. Because a comprehensive comparison between FKM and RKM is lacking in the literature so far, a

  2. Undergraduate Students' Initial Conceptions of Factorials

    Science.gov (United States)

    Lockwood, Elise; Erickson, Sarah

    2017-01-01

    Counting problems offer rich opportunities for students to engage in mathematical thinking, but they can be difficult for students to solve. In this paper, we present a study that examines student thinking about one concept within counting, factorials, which are a key aspect of many combinatorial ideas. In an effort to better understand students'…

  3. The Idea Factory: An Interactive Intergroup Exercise

    Science.gov (United States)

    Rosh, Lisa; Leach, Evan

    2011-01-01

    This article outlines the Idea Factory exercise, an interactive exercise designed to help participants examine group, individual, and organizational factors that affect intergroup conflict. Specific emphasis is placed on exploring the relationship between intra- and intergroup dynamics and identifying managerial practices that foster effective…

  4. Business plan Feed Factory Zambezi Valley, Mozambique

    NARCIS (Netherlands)

    Vernooij, A.G.; Wilschut, S.

    2015-01-01

    This business plan focuses on the establishment of a poultry feed factory, one of the essential elements of a sustainable and profitable poultry meat value chain. There is a growing demand for poultry meat in the Tete Province, and currently a large part of the consumed broilers come from other

  5. MODEL PENGELOLAAN TEACHING FACTORY SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    M Burhan R Wijaya

    2013-02-01

    Full Text Available This study aims to identify and develop management models Factory Teaching Vocational School through a series of tests and validation of the model with the approach of reasearch and Development. Teaching Factory Management Models at Vocational Schools is a concept that combines learning management approach learning Competency Based Training (CBT and Production Based Training (PBT in the real atmosphere so that the process of achieving competence or skill skills life skills (life skills in accordance with the standards of graduate work in the industrial world. In particular, this study aims to formulate design management model development Teaching Factory Vocational School. To achieve the research objectives above using the approach of Research and Development, through preliminary studies, design development models, testing and validation. Preliminary study phase is planned to take the flow / stage as follows: the study of literature, study / collection of field data, and a description and analysis of field findings (factual, namely: (1 the description of the characteristics of vocational school with a standard performance indicators that can be poured as the content of the development of Teaching Factory, (2 description of the characteristics and potential development group management model Tefa as an outcome groups to develop and implement management models Tefa for Vocational Schools (3 description of the characteristics of potential stakeholders to support the development and implementation TEFA management model, and (4 preparation of the management model TEFA for Vocational Schools excellence and innovative. Trial design done on a limited scale model group. Then the model was accompanied by outcome group to develop and implement a model TEFA for Vocational Schools to determine whether the model developed can be applied correctly. Data analysis in this study, the preliminary study stage, the findings or the facts about productive learning

  6. Residues leaching from 'Factory of barren ores'

    International Nuclear Information System (INIS)

    Rakhmatov, N.; Khakimov, N.; Nazarov, Kh.M.; Barotov, A.M.

    2012-01-01

    The objective of the present work is safe management of residues from Factory of Barren Ores, their reprocessing, expenditures reduction for remediation of Istiklol city former uranium tailings. For this purpose, some experiences were adopted - Factory of Barren Ores tailing use for filling up the open pit where water with uranium content 3-5 mg/l is located. Factory of Barren Ores waste are passed through heap leaching and have some amount of uranium salts dissolved in water. Thus, we propose to dissolve uranium from Factory of Barren Ores wastes with uranium bearing water flowing out from gallery and filling up the open-pit by radioactive wastes. In so doing, uranium content flowing out from gallery will increase twice, and further, passing them through apricot's shell, as a sorbent, we will clean the water against radionuclides. Residue samples with uranium content 0,015% from Factory of Barren Ores and uranium bearing waters from gallery 1 with uranium content 0,0025 g/l were used for laboratory tests. After which, a slurry was prepared by means of residue mixing with water in ratio of solid and liquid phases (S:L) - 1:2 and 9,7 ml of sulfuric acid (Ρ=1,82) was added which corresponds consumption by H 2 SO 4 176,54 kg/t. For the first test, leaching was carried out during 4 hours at ph=1,6 at room temperature. For the second test, leaching was carried out at 60 d eg C a nd ph=1,6 during 4 hours. Slurry heating and mixing was carried out by means of magnetic mixer. The basic residue leaching indicators are provided in this article.

  7. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  8. Repeated Causal Decision Making

    Science.gov (United States)

    Hagmayer, York; Meder, Bjorn

    2013-01-01

    Many of our decisions refer to actions that have a causal impact on the external environment. Such actions may not only allow for the mere learning of expected values or utilities but also for acquiring knowledge about the causal structure of our world. We used a repeated decision-making paradigm to examine what kind of knowledge people acquire in…

  9. simple sequence repeat (SSR)

    African Journals Online (AJOL)

    In the present study, 78 mapped simple sequence repeat (SSR) markers representing 11 linkage groups of adzuki bean were evaluated for transferability to mungbean and related Vigna spp. 41 markers amplified characteristic bands in at least one Vigna species. The transferability percentage across the genotypes ranged ...

  10. Evaluation of ring impedance of the Photon Factory storage ring

    International Nuclear Information System (INIS)

    Kiuchi, T.; Izawa, M.; Tokumoto, S.; Hori, Y.; Sakanaka, S.; Kobayashi, M.; Kobayakawa, H.

    1992-05-01

    The loss parameters of the ducts in the Photon Factory (PF) storage ring were evaluated using the wire method and the code TBCI. Both the measurement and the calculation were done for a different bunch length (σ) ranging from 23 to 80 ps. The PF ring impedance was estimated to be |Z/n|=3.2 Ω using the broadband impedance model. The major contribution to the impedance comes from the bellows and the gate valve sections. Improvements of these components will lower the ring impedance by half. (author)

  11. Characterization of undulator radiation at the Photon Factory

    International Nuclear Information System (INIS)

    Maezawa, Hideki; Kitamura, Hideo; Sasaki, Taizo; Suzuki, Yoshio

    1986-01-01

    Spectra of undulator radiation of the Photon Factory undulator, model PMU-2, were measured in a scale of absolute brightness in the soft X-ray region for various values of the K-parameter from 0.72 to 1.66. A significant reduction of the peak brightness was observed, whereas we also observed a relatively sharp edge at the high energy side of the first harmonic. The results show that the peak brightness and the band width are highly dependent on the beam parameters and the geometry of spectral observation. (orig.)

  12. Characterization of undulator radiation at the photon factory

    Science.gov (United States)

    Maezawa, Hideki; Suzuki, Yoshio; Kitamura, Hideo; Sasaki, Taizo

    1986-05-01

    Spectra of undulator radiation of the Photon Factory undulator, model PMU-2, were measured in a scale of absolute brightness in the soft X-ray region for various values of the K-parameter from 0.72 to 1.66. A significant reduction of the peak brightness was observed, whereas we also observed a relatively sharp edge at the high energy side of the first harmonic. The results show that the peak brightness and the band width are highly dependent on the beam parameters and the geometry of spectral observation.

  13. DEVELOPMENT OF EVALUATION OF A QUANTITATIVE VIDEO-FLUORESCENCE IMAGING SYSTEM AND FLUORESCENT TRACER FOR MEASURING TRANSFER OF PESTICIDE RESIDUES FROM SURFACES TO HANDS WITH REPEATED CONTACTS

    Science.gov (United States)

    A video imaging system and the associated quantification methods have been developed for measurement of the transfers of a fluorescent tracer from surfaces to hands. The highly fluorescent compound riboflavin (Vitamin B2), which is also water soluble and non-toxic, was chosen as...

  14. Flow-based approach for holistic factory engineering and design

    OpenAIRE

    Constantinescu, C.; Westkämper, E.

    2010-01-01

    The engineering of future factories requires digital tools along life cycle phases from investment planning to ramp-up. Manufacturers need scientific-based integrated highly dynamic data management systems for the participative and integrated factory planning. The paper presents a new approach for the continuously integrated product design, factory and process planning, through a service-oriented architecture for the implementation of digital factory tools. A first prototype of the digital fa...

  15. An Interactive Simulation Tool for Production Planning in Bacon Factories

    DEFF Research Database (Denmark)

    Nielsen, Jens Frederik Dalsgaard; Nielsen, Kirsten Mølgaard

    1994-01-01

    The paper describes an interactive simulation tool for production planning in bacon factories. The main aim of the tool is to make it possible to combine the production plans of all parts of the factory......The paper describes an interactive simulation tool for production planning in bacon factories. The main aim of the tool is to make it possible to combine the production plans of all parts of the factory...

  16. The Virtual Factory Teaching System (VFTS): Project Review and Results.

    Science.gov (United States)

    Kazlauskas, E. J.; Boyd, E. F., III; Dessouky, M. M.

    This paper presents a review of the Virtual Factory Teaching (VFTS) project, a Web-based, multimedia collaborative learning network. The system allows students, working alone or in teams, to build factories, forecast demand for products, plan production, establish release rules for new work into the factory, and set scheduling rules for…

  17. e sup + e sup - Factories: PEP-II, KEKB, DAPHINE

    CERN Document Server

    Guiducci, S

    2001-01-01

    In 1999 two B-factories, PEP-II and KEK, and a PHI-factory, DAPHINE, started their physics experiments. A status report of the three factories is presented. A description of the interaction regions, strongly influenced by the detector requirements, and of the machine background in the detectors is presented.

  18. Classifying individuals based on a densely captured sequence of vital signs: An example using repeated blood pressure measurements during hemodialysis treatment.

    Science.gov (United States)

    Goldstein, Benjamin A; Chang, Tara I; Winkelmayer, Wolfgang C

    2015-10-01

    Electronic Health Records (EHRs) present the opportunity to observe serial measurements on patients. While potentially informative, analyzing these data can be challenging. In this work we present a means to classify individuals based on a series of measurements collected by an EHR. Using patients undergoing hemodialysis, we categorized people based on their intradialytic blood pressure. Our primary criteria were that the classifications were time dependent and independent of other subjects. We fit a curve of intradialytic blood pressure using regression splines and then calculated first and second derivatives to come up with four mutually exclusive classifications at different time points. We show that these classifications relate to near term risk of cardiac events and are moderately stable over a succeeding two-week period. This work has general application for analyzing dense EHR data. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Portable Material Culture and Death Factory Auschwitz

    Directory of Open Access Journals (Sweden)

    Adrian T. Myers

    2007-11-01

    Full Text Available Like any other factory, the death factory of Auschwitz consumed primary materials and produced secondary products. Unique to Auschwitz, though, is that the primary material consumed was human life; not just the life of the breathing human body, but also the material possessions associated with that life. The detritus of this most efficient genocide – clothing, jewellery, food, corpses – was appropriated and put to new uses by the SS and the prisoners. Others have recognised the various postwar material cultural outcomes of the camp: the writing, the film, the theatre, the art, the tourism. This article, however, demonstrates that the material culture of Auschwitz is not a phenomenon exclusive to the postwar era. It focuses on the fact that inside the camp during the war, despite the landscape of death and deprivation, intimate interaction between humans and material culture continued.

  20. JINR tau-charm factory design study

    International Nuclear Information System (INIS)

    Perel'shtejn, E.; Aleksandrov, V.; Antropov, V.

    1993-01-01

    The review on tau-charm factory in JINR (Dubna) is presented. The structure scheme of tau-charm factory is described. The problems on injection complex are discussed: the composition, the working regime and parameters. The magnetic lattice of a booster is described. A versatile magnet lattice is used in tau-charm collider. It can realize both conventional flat beam scheme and monochromatization scheme. The results of chromaticity correction in high emittance lattice are presented. The list of parameters of tau-charm collider is given. The technical proposal of magnetic elements of booster and collider and their power supplies is made, as well as RF power supply in collider and vacuum system in its periodic cell. 12 refs.; 12 figs.; 3 tabs

  1. B factory rf system design issues

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1992-06-01

    We discuss the issues of relevance to the design of a B factory RF system. First, the general parameter regime is outlined, and the reasons behind certain commonly made choices are indicated. This regime involves high beam currents, and many relatively short bunches. Next, the physics difficulties associated with coupled-bunch instabilities are described briefly. We then describe in general terms the alternative approaches taken by various B factory designers, the motivation for these choices, and the technical issues raised by them. Technical solutions have been proposed for both the room-temperature and the superconducting RF scenarios, and considerable R ampersand D is being carried out worldwide to confirm and optimize these solutions

  2. Physics at e+e- factories

    International Nuclear Information System (INIS)

    Lueth, V.; MacFarlane, D.B.

    1991-02-01

    Feasible designs are well advanced for high-luminosity e + e - storage rings which produce B 0 bar B 0 pairs either at rest or, in what appears to be a more promising option, boosted in the detector frame. Facilities which could provide samples of 30--100 fb -1 per year on the Υ(4S) will be proposed in early 1991. Here we examine the principal physics goal of such B Factories, namely CP violation in the b system. Methods in a variety of channels, estimated event samples, and detector requirements are all considered. We conclude that the physics argument for an e + e - B Factory is well documented, and compelling. 50 refs., 22 figs., 10 tabs

  3. B factory RF system design issues

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1992-01-01

    We discuss the issues of relevance to the design of a B factory RF system. First, the general parameter regime is outlined, and the reasons behind certain commonly made choices are indicated. This regime involves high beam currents, and many relatively short bunches. Next, the physics difficulties associated with coupled-bunch instabilities are described briefly. We then describe in general terms the alternative approaches taken by various B factory designers, the motivation for these choices, and the technical issues raised by them. Technical solutions have been proposed for both the room-temperature and the superconducting RF scenarios, and considerable R ampersand D is being carried out worldwide to confirm and optimize these solutions

  4. Review of proposed kaon factory facilities

    International Nuclear Information System (INIS)

    Macek, R.J.

    1985-01-01

    A number of proton accelerator facilities, popularly called ''Kaon Factories,'' have been proposed to extend the intensity frontier from about 1 GeV to higher energies in the range of 15 to 45 GeV. Seven proposed facilities - LAMPF II, TRIUMF II, SIN II, AGS II, KEK, MUNICH, and KYOTO - are reviewed with emphasis on capabilities of the experimental facilities. Costs and the choice of energy and current are also discussed. 7 refs., 29 figs., 7 tabs

  5. Design studies for the Positron Factory

    International Nuclear Information System (INIS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Masuno, S.; Kawasuso, A.; Sakai, T.; Takizawa, H.; Yotsumoto, K.; Honda, Y.; Tagawa, S.

    1996-01-01

    In the design study for the Positron Factory, a feasibility of simultaneous extraction of multi-channel monoenergetic positron beams, which had been proposed at the previous conference (Linac 94), was demonstrated by an experiment using an electron linac. On the basis of the experimental result, an efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is proposed. (author)

  6. Muon front end for the neutrino factory

    Directory of Open Access Journals (Sweden)

    C. T. Rogers

    2013-04-01

    Full Text Available In the neutrino factory, muons are produced by firing high-energy protons onto a target to produce pions. The pions decay to muons and pass through a capture channel known as the muon front end, before acceleration to 12.6 GeV. The muon front end comprises a variable frequency rf system for longitudinal capture and an ionization cooling channel. In this paper we detail recent improvements in the design of the muon front end.

  7. Muon front end for the neutrino factory

    CERN Document Server

    Rogers, C T; Prior, G; Gilardoni, S; Neuffer, D; Snopok, P; Alekou, A; Pasternak, J

    2013-01-01

    In the neutrino factory, muons are produced by firing high-energy protons onto a target to produce pions. The pions decay to muons and pass through a capture channel known as the muon front end, before acceleration to 12.6 GeV. The muon front end comprises a variable frequency rf system for longitudinal capture and an ionization cooling channel. In this paper we detail recent improvements in the design of the muon front end.

  8. LAMPF: the meson factory. A LASL monograph

    Energy Technology Data Exchange (ETDEWEB)

    Allred, J.C.

    1977-08-01

    A general and simplified introduction to the entire concept of LAMPF is given in terms of its experimental capabilities. Parts of the current experimental program are used as illustrative examples. Topics discussed include: (1) the evolution of the meson factory; (2) accelerator construction; (3) strong focusing; (4) accelerator innovations at LAMPF; (5) photons and pions; (6) muons as nuclear probes; (7) nuclear chemistry; (8) radiobiology and medical applications; (9) radioisotope production; (10) materials testing; and (11) LAMPF management and users group. (PMA)

  9. Collective issues related to B-factories

    International Nuclear Information System (INIS)

    Pestrikov, D.V.

    1993-02-01

    This report reviews the limitations on the performance of the planned B- and Φ-factories due to the collective interactions of stored bunches. Together with the traditional revision of the limitations due to the single- and multi-bunch interaction with surrounding electrodes, we briefly discuss in this report the limitations on the performance due to collective beam-beam instabilities of colliding beams and instabilities due to the collective interaction of beams with the ions. (author)

  10. LAMPF: the meson factory. A LASL monograph

    International Nuclear Information System (INIS)

    Allred, J.C.

    1977-08-01

    A general and simplified introduction to the entire concept of LAMPF is given in terms of its experimental capabilities. Parts of the current experimental program are used as illustrative examples. Topics discussed include: (1) the evolution of the meson factory; (2) accelerator construction; (3) strong focusing; (4) accelerator innovations at LAMPF; (5) photons and pions; (6) muons as nuclear probes; (7) nuclear chemistry; (8) radiobiology and medical applications; (9) radioisotope production; (10) materials testing; and (11) LAMPF management and users group

  11. The Factory of the Future, Group Exhibition

    OpenAIRE

    Dean, Lionel T.

    2016-01-01

    3D Printing, The factory of the future, Lieu du Design (centre for Design), Paris This exhibition dedicated entirely to 3D printing technology was billed as “the first in France wholly devoted to exploring the interdisciplinary and multifaceted topic of 3D printing technology and its undeniable influence on everything from industry, to economics, to creative and social issues, demonstrated to the public through achievements in the fields of 3D design, 3D printed architecture, 3D printed fa...

  12. Cell factories for a sustainable world

    DEFF Research Database (Denmark)

    Kindtler, Jens William

    2016-01-01

    The Novo Nordisk Foundation Center for Biosustainability (CFB) is a university research center under the Technical University of Denmark within the field of design, engineering and construction of superior cell factories for the production of biopharmaceuticals, anti-infective compounds, industrial......-spectrum inhibitors against multi-drug resistant (MDR) Gram-negative bacterial pathogens using co-Adaptive Laboratory Evolution, 3. Design and engineering of E. coli and Saccharomyces cerevisiae for biobased production of various classes of chemicals. CFB has 230 employees....

  13. A biophysical model for transcription factories

    International Nuclear Information System (INIS)

    Canals-Hamann, Ana Z; Neves, Ricardo Pires das; Reittie, Joyce E; Iñiguez, Carlos; Soneji, Shamit; Enver, Tariq; Buckle, Veronica J; Iborra, Francisco J

    2013-01-01

    Transcription factories are nuclear domains where gene transcription takes place although the molecular basis for their formation and maintenance are unknown. In this study, we explored how the properties of chromatin as a polymer may contribute to the structure of transcription factories. We found that transcriptional active chromatin contains modifications like histone H4 acetylated at Lysine 16 (H4K16ac). Single fibre analysis showed that this modification spans the entire body of the gene. Furthermore, H4K16ac genes cluster in regions up to 500 Kb alternating active and inactive chromatin. The introduction of H4K16ac in chromatin induces stiffness in the chromatin fibre. The result of this change in flexibility is that chromatin could behave like a multi-block copolymer with repetitions of stiff-flexible (active-inactive chromatin) components. Copolymers with such structure self-organize through spontaneous phase separation into microdomains. Consistent with such model H4K16ac chromatin form foci that associates with nascent transcripts. We propose that transcription factories are the result of the spontaneous concentration of H4K16ac chromatin that are in proximity, mainly in cis

  14. Ultrastructural Characterization of Zika Virus Replication Factories

    Directory of Open Access Journals (Sweden)

    Mirko Cortese

    2017-02-01

    Full Text Available Summary: A global concern has emerged with the pandemic spread of Zika virus (ZIKV infections that can cause severe neurological symptoms in adults and newborns. ZIKV is a positive-strand RNA virus replicating in virus-induced membranous replication factories (RFs. Here we used various imaging techniques to investigate the ultrastructural details of ZIKV RFs and their relationship with host cell organelles. Analyses of human hepatic cells and neural progenitor cells infected with ZIKV revealed endoplasmic reticulum (ER membrane invaginations containing pore-like openings toward the cytosol, reminiscent to RFs in Dengue virus-infected cells. Both the MR766 African strain and the H/PF/2013 Asian strain, the latter linked to neurological diseases, induce RFs of similar architecture. Importantly, ZIKV infection causes a drastic reorganization of microtubules and intermediate filaments forming cage-like structures surrounding the viral RF. Consistently, ZIKV replication is suppressed by cytoskeleton-targeting drugs. Thus, ZIKV RFs are tightly linked to rearrangements of the host cell cytoskeleton. : Cortese et al. show that ZIKV infection in both human hepatoma and neuronal progenitor cells induces drastic structural modification of the cellular architecture. Microtubules and intermediate filaments surround the viral replication factory composed of vesicles corresponding to ER membrane invagination toward the ER lumen. Importantly, alteration of microtubule flexibility impairs ZIKV replication. Keywords: Zika virus, flavivirus, human neural progenitor cells, replication factories, replication organelles, microtubules, intermediate filaments, electron microscopy, electron tomography, live-cell imaging

  15. Engineering Robustness of Microbial Cell Factories.

    Science.gov (United States)

    Gong, Zhiwei; Nielsen, Jens; Zhou, Yongjin J

    2017-10-01

    Metabolic engineering and synthetic biology offer great prospects in developing microbial cell factories capable of converting renewable feedstocks into fuels, chemicals, food ingredients, and pharmaceuticals. However, prohibitively low production rate and mass concentration remain the major hurdles in industrial processes even though the biosynthetic pathways are comprehensively optimized. These limitations are caused by a variety of factors unamenable for host cell survival, such as harsh industrial conditions, fermentation inhibitors from biomass hydrolysates, and toxic compounds including metabolic intermediates and valuable target products. Therefore, engineered microbes with robust phenotypes is essential for achieving higher yield and productivity. In this review, the recent advances in engineering robustness and tolerance of cell factories is described to cope with these issues and briefly introduce novel strategies with great potential to enhance the robustness of cell factories, including metabolic pathway balancing, transporter engineering, and adaptive laboratory evolution. This review also highlights the integration of advanced systems and synthetic biology principles toward engineering the harmony of overall cell function, more than the specific pathways or enzymes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Neutrinos: from the Workshop to the Factory

    CERN Multimedia

    2001-01-01

    Over the next 5 years much work will be done to reach a theoretical and practical description of a neutrino factory. How could this project turn out to be an interesting future option for CERN? Neutrino beams travelling from CERN to the Canary Islands? And to the Svalbard archipelago in Norway? Or even to the Pyhaesalmi Mine in Finland? Why neutrinos? And why so far? The answers provide one of CERN's next challenging options: the construction of a high-energy muon storage ring to provide neutrino beams. This project, nicknamed 'neutrino factory', now figures in CERN's middle term plan as a recognized and supported research and development project. International collaborations, with other European laboratories and also with America and Japan, are now being set up. Long baseline locations for neutrino oscillations studies at a CERN based neutrino factory. Early in its history, LEP established that there exist just three kinds of light neutrinos, those associated with the electron, muon, and tau leptons. For a...

  17. An asymmetric B factory based on PEP

    Energy Technology Data Exchange (ETDEWEB)

    1991-02-01

    In this report we describe a design for a high-luminosity Asymmetric B Factory to be built in the PEP tunnel on the SLAC site. This proposal, a collaborative effort SLAC, LBL, and LLNL, is the culmination of more than two years of effort aimed at the design and construction of an asymmetric e{sup +}e{sup {minus}} collider capable of achieving a luminosity of L = 3 {times} 10{sup 33} cm{sup {minus}2} s{sup {minus}1}. The configuration adopted utilizes two storage rings, and electron ring operating at 9 GeV and a positron ring at 3.1 GeV, each with a circumference of 2200 m. The high-energy ring is an upgrade of the PEP storage ring at SLAC; all PEP magnets and most power supplies will be reused. The upgrade consists primarily of replacing the PEP vacuum chamber and RF system with newly designed versions optimized for the high-current environment of the B Factory. The low-energy ring will be newly constructed and will be situated atop the high-energy ring in the PEP tunnel. Utilities already installed in the PEP tunnel are largely sufficient to operate the two B Factory storage rings.

  18. An asymmetric B factory based on PEP

    International Nuclear Information System (INIS)

    1991-02-01

    In this report we describe a design for a high-luminosity Asymmetric B Factory to be built in the PEP tunnel on the SLAC site. This proposal, a collaborative effort SLAC, LBL, and LLNL, is the culmination of more than two years of effort aimed at the design and construction of an asymmetric e + e - collider capable of achieving a luminosity of L = 3 x 10 33 cm -2 s -1 . The configuration adopted utilizes two storage rings, and electron ring operating at 9 GeV and a positron ring at 3.1 GeV, each with a circumference of 2200 m. The high-energy ring is an upgrade of the PEP storage ring at SLAC; all PEP magnets and most power supplies will be reused. The upgrade consists primarily of replacing the PEP vacuum chamber and RF system with newly designed versions optimized for the high-current environment of the B Factory. The low-energy ring will be newly constructed and will be situated atop the high-energy ring in the PEP tunnel. Utilities already installed in the PEP tunnel are largely sufficient to operate the two B Factory storage rings

  19. Changing the size of a mirror-reflected hand moderates the experience of embodiment but not proprioceptive drift: a repeated measures study on healthy human participants.

    Science.gov (United States)

    Wittkopf, Priscilla G; Lloyd, Donna M; Johnson, Mark I

    2017-06-01

    Mirror visual feedback is used for reducing pain and visually distorting the size of the reflection may improve efficacy. The findings of studies investigating size distortion are inconsistent. The influence of the size of the reflected hand on embodiment of the mirror reflection is not known. The aim of this study was to compare the effect of magnifying and minifying mirror reflections of the hand on embodiment measured using an eight-item questionnaire and on proprioceptive drift. During the experiment, participants (n = 45) placed their right hand behind a mirror and their left hand in front of a mirror. Participants watched a normal-sized, a magnified and a minified reflection of the left hand while performing synchronised finger movements for 3 min (adaptive phase). Measurements of embodiment were taken before (pre) and after (post) synchronous movements of the fingers of both hands (embodiment adaptive phase). Results revealed larger proprioceptive drift post-adaptive phase (p = 0.001). Participants agreed more strongly with questionnaire items associated with location, ownership and agency of the reflection of the hand post-adaptive phase (p embodiment of the reflection of the hand. Magnifying and minifying the reflection of the hand has little effect on proprioceptive drift, but it weakens the subjective embodiment experience. Such factors need to be taken into account in future studies using this technique, particularly when assessing mirror visual feedback for pain management.

  20. Testing strong factorial invariance using three-level structural equation modeling

    NARCIS (Netherlands)

    Jak, Suzanne

    Within structural equation modeling, the most prevalent model to investigate measurement bias is the multigroup model. Equal factor loadings and intercepts across groups in a multigroup model represent strong factorial invariance (absence of measurement bias) across groups. Although this approach is

  1. Repetibilidade e número mínimo de medições para caracteres de cacho de bacabi (Oenocarpus mapora Repeatability and minimum number of measurements for characters of bacabi palm (Oenocarpus mapora racemes

    Directory of Open Access Journals (Sweden)

    Maria do Socorro Padilha de Oliveira

    2010-12-01

    potential for commercial and food uses, but has not been well studied. The objectives of this study were to estimate the repeatability coefficients, determine predictability and the number of measurements needed for raceme characters of this palm. 27 individuals of bacabi that belong to the Germplasm Bank of Oenocarpus/Jessenia at Embrapa Eastern Amazon, in Belém, PA, Brazil were evaluated. Three fully matured racemes from each plant were sampled to measure six characters: total weight of raceme (TWR and fruit weight per raceme (FWR, number of rachillae per raceme (NRR, rachis length per raceme (RLR, weight of 100 fruits (WHF and fruit yield per raceme (FER. The repeatability estimates were obtained by three statistical methods: analysis of variance; principal components; and structural analysis. For all characters, the estimates of repeatability coefficients presented values with very similar magnitudes in the three methods. The estimates of repeatability coefficients and determination coefficients were relatively high (r 0.60 and R2 81.7% for the characters FER and NRR, showing genotype regularity for these raceme measurements. For these characters, the minimum number of racemes necessary to estimate the true character value of the genotypes was thirteen (FER and five (NRR, with 95% reliability. The remaining characters showed repeatabilities and determination coefficients with medium to low values, indicating the need for better environmental control to make the measurements.

  2. CRISPR/Cas9-mediated genome engineering of CHO cell factories: application and perspectives

    DEFF Research Database (Denmark)

    Lee, Jae Seong; Grav, Lise Marie; Lewis, Nathan E.

    2015-01-01

    repeat (CRISPR)/CRISPR-associated protein 9 (Cas9) system enables rapid,easy and efficient engineering of mammalian genomes. It has a wide range of applications frommodification of individual genes to genome-wide screening or regulation of genes. Facile genomeediting using CRISPR/Cas9 empowers...... researchers in the CHO community to elucidate the mechanisticbasis behind high level production of proteins and product quality attributes of interest. Inthis review, we describe the basis of CRISPR/Cas9-mediated genome editing and its applicationfor development of next generation CHO cell factories while...... highlighting both future perspectivesand challenges. As one of the main drivers for the CHO systems biology era, genome engineeringwith CRISPR/Cas9 will pave the way for rational design of CHO cell factories....

  3. The effects of repeated testing, simulated malingering, and traumatic brain injury on high-precision measures of simple visual reaction time

    Directory of Open Access Journals (Sweden)

    David L Woods

    2015-11-01

    Full Text Available Simple reaction time (SRT, the latency to respond to a stimulus, has been widely used as a basic measure of processing speed. In the current experiments, we examined clinically-relevant properties of a new SRT test that presents visual stimuli to the left or right hemifield at varying stimulus onset asynchronies. Experiment 1 examined test-retest reliability in participants who underwent three test sessions at weekly intervals. In the first test, log-transformed (log-SRT z-scores, corrected for the influence of age and computer-use, were well predicted by regression functions derived from a normative population of 189 control participants. Test-retest reliability of log-SRT z-scores was measured with an intraclass correlation coefficient (ICC = 0.83 and equaled or exceeded those of other SRT tests and other widely used tests of processing speed that are administered manually. No significant learning effects were observed across test sessions. Experiment 2 investigated the same participants when instructed to malinger during a fourth testing session: 94% showed abnormal log-SRT z-scores, with 83% producing log-SRT z-scores exceeding a cutoff of 3.0, a degree of abnormality never seen in full-effort conditions. Thus, a log-SRT z-score cutoff of 3.0 had a sensitivity (83% and specificity (100% that equaled or exceeded that of existing symptom validity tests. We argue that even expert malingerers, fully informed of the malingering-detection metric, would be unable to successfully feign impairments on the SRT test because of the precise control of SRT latencies that would be required. Experiment 3 investigated 26 patients with traumatic brain injury (TBI tested more than one year post-injury. The 22 patients with mild TBI showed insignificantly faster SRTs than controls, but a small group of four patients with severe TBI showed slowed SRTs. Simple visual reaction time is a reliable measure of processing speed that is sensitive to the effects of

  4. Quantum mechanics paradoxes at the Φ-factory

    International Nuclear Information System (INIS)

    Ghirardi, G.C.; Grassi, R.; Weber, T.

    1991-04-01

    We discuss the possibility of performing experiments allowing one to test quantum mechanics versus any local realistic model within the context of the physics at the Φ-factory. After having sketched the main features of the physical process under consideration and having focused the locality requirements for it, we derive Bell's inequality for the two-meson system. Comparison with quantum predictions shows that the inequality is not violated for any choice of the parameters characterizing the measurement process. Contrary to the case of spin variables, there is then no way to exclude, by experiments at the Φ-factory, the possibility of a local realistic description of the process. A recent suggestion about a test of quantum predictions versus the assumption of a spontaneous factorization mechanism, as well as the claimed validity of an inequality which is different from Bell's one, are also discussed. The general conclusion is that the Φ-factory facility does not seem to open new ways of testing quantum mechanics versus alternative general schemes of the type which are usually regarded as worth considering the debate about locality and quantum mechanics. The concluding Section is devoted to making clear our position with respect to the problems discussed in this paper. It is pointed out that, in our opinion, the existing experimental evidence makes already clear that one has to accept the ''mysterious'' features of microscopic systems. The really crucial problem is that of investigating whether one can restore a coherent worldview which generally conforms with our experience at the macroscopic level, by keeping all highly successful predictions of quantum theory at the microscopic one. (author). 22 refs

  5. [Risk assessment and countermeasure of BTEX in pesticide factory].

    Science.gov (United States)

    Pang, Bo; Wang, Tie-Yu; Du, Li-Yu; Tan, Bing; Zhu, Zhao-Yun; Lu, Yong-Long

    2013-07-01

    BTEX are important environmental pollutants, harmful to human through respiratory inhalation, digestive tract and skin contact, and also have teratogenic, mutagenic and carcinogenic effects. BTEX were detected in multi-media to identify their distributions and assess their human health risk in a pesticide factory in Hebei province. Purge and trap GC-MS, adsorption/thermal desorption GC chromatography and the health risk assessment model were applied, and corresponding management measures were proposed. The results showed that BTEX existed in soil, dust, air, groundwater and wastewater. The concentration of BTEX in dust of the production area was 7.33 mg x kg(-1), in particular the concentration of toluene was 5.64 mg x kg(-1), exceeding the Canadian industrial land standard. Building three scenarios for working more than 10 years, 20 years and 30 years, the total non-carcinogens index was 4.19 x10(-3), 8.25 x 10(-3) and 1.22 x 10(-2), respectively, all lower than 1; the carcinogens index of benzene was 1.70 x 10(-7), 3.34 x 10(-7) and 4.92 x 10(-7), respectively, all lower than 10(-6). It indicated that there was no significant non-carcinogens and carcinogens hazard to workers inside the factory, but they might be exposed to more health risks if their work experience increase. Finally, recommendations for improving the environmental quality and personnel security in the factory were proposed based on the research results.

  6. County level socioeconomic position, work organization and depression disorder: a repeated measures cross-classified multilevel analysis of low-income nursing home workers.

    Science.gov (United States)

    Muntaner, Carles; Li, Yong; Xue, Xiaonan; Thompson, Theresa; O'Campo, Patricia; Chung, Haejoo; Eaton, William W

    2006-12-01

    This study simultaneously tests the effect of county, organizational, workplace, and individual level variables on depressive disorders among low-income nursing assistants employed in US nursing homes. A total of 482 observations are used from two waves of survey data collection, with an average two-year interval between initial and follow-up surveys. The overall response rate was 62 percent. The hierarchically structured data was analyzed using multilevel modeling to account for cross-classifications across levels of data. Nursing assistants working in nursing homes covered by a single union in three states were asked about aspects of their working conditions, job stress, physical and mental health status, individual and family health-care needs, household economics and household strain. The 241 nursing assistants who participated in this study were employed in 34 nursing homes and lived in 49 counties of West Virginia, Ohio and Kentucky. The study finds that emotional strain, related to providing direct care to elderly and disabled clients, is associated with depressive disorder, as is nursing home ownership type (for-profit versus not-for-profit). However, when controlling for county level socioeconomic variables (Gini index and proportion of African Americans living in the county), neither workplace nor organizational level variables were found to be statistically significant associated with depressive disorder. This study supports previous findings that emotional demand in health-care environments is an important correlate of mental health. It also adds empirical evidence to support a link between financial strain and depression in US women. While this study does not find that lack of a seniority wage benefits--a factor that can conceivably exacerbate financial strain over time--is associated with depressive disorder among low-income health-care workers, it does find county level measures of poverty to be statistically significant predictors of depressive

  7. Long-term aerobic exercise and omega-3 supplementation modulate osteoporosis through inflammatory mechanisms in post-menopausal women: a randomized, repeated measures study

    Directory of Open Access Journals (Sweden)

    Kanaley Jill

    2011-10-01

    Full Text Available Abstract Background Evidence indicates that dietary fats and physical activity influence bone health. The purpose of this study was to examine the effects of long-term aerobic exercise and omega-3 (N-3 supplementation on serum inflammatory markers, bone mineral density (BMD, and bone biomarkers in post-menopausal women. Methods Seventy-nine healthy sedentary post-menopausal women aged 58-78 years participated in this study. Subjects were randomized to one of 4 groups: exercise + supplement (E+S, n = 21, exercise (E, n = 20, supplement (S, n = 20, and control (Con, n = 18 groups. The subjects in the E+S and E groups performed aerobic exercise training (walking and jogging up to 65% of HRmax, three times a week for 24 weeks. Subjects in the E+S and S groups consumed 1000 mg/d N-3 for 24 weeks. The lumbar spine (L2-L4 and femoral neck BMD, serum tumor necrosis factor (TNF α, interleukin (IL 6, prostaglandin (PG E2, estrogen, osteocalcin, 1, 25-dihydroxyvitamin D3 (1, 25 Vit D, C-telopeptide (CTX, parathyroid hormone (PTH and calcitonin (CT were measured at baseline, the end of week 12 and 24. Results Serum estrogen, osteocalcin, 1, 25 Vit D, CT, L2-L4 and femoral neck BMD measures increased (P 2 decreased (P 2-L4 and femoral neck BMD, estrogen, osteocalcin, and CT were negatively (P 2. PTH and CT were correlated positively and negatively with IL-6, respectively (P Conclusions The present study demonstrates that long-term aerobic exercise training plus N-3 supplementation have a synergistic effect in attenuating inflammation and augmenting BMD in post-menopausal osteoporosis.

  8. Accuracy of repeated measurements of late-night salivary cortisol to screen for early-stage recurrence of Cushing's disease following pituitary surgery.

    Science.gov (United States)

    Danet-Lamasou, Marie; Asselineau, Julien; Perez, Paul; Vivot, Alexandre; Nunes, Marie-Laure; Loiseau, Hugues; San-Galli, François; Cherifi-Gatta, Blandine; Corcuff, Jean-Benoît; Tabarin, Antoine

    2015-02-01

    The performance of late-night salivary cortisol (LNSC) to accurately screen for postoperative recurrence of Cushing's disease (CD) at an early stage is unknown. The aim of this study was to compare the accuracy of multiple sampling strategies to suggest the optimal number of LNSC samples needed for diagnosing post-surgical recurrences of CD at an early stage. Retrospective analysis in a single centre. Thirty-six patients in surgical remission of CD had successive measurements of LNSC, defined as 'sequences', using a locally modified RIA assay as part of long-term follow-up (69·2 ± 10·6 months). Patients underwent an extensive biochemical evaluation within 3 months before or after a sequence of saliva sampling and were classified as being in remission or in early-stage recurrence. The accuracy of three diagnostic strategies combining two, three or four LNSC results from a sequence was estimated using areas under the ROC curves (AUC), sensitivity, specificity and predictive values. Forty-four sequences of LNSC measurements were available. Fifty-two percent of sequences were performed during early-stage recurrence. The intrasequence variability of LNSC was higher during recurrence than during remission (medians of SDs: 2·1 vs 0·5 nm; P recurrence of CD. However, due to a major within-patient variability of LNSC from 1 day to another, a screening strategy using three or four samples collected on successive days may be recommended to detect early-stage recurrence of CD with a high accuracy. © 2014 John Wiley & Sons Ltd.

  9. Evaluation of repeated measurements of radon-222 concentrations in well water sampled from bedrock aquifers of the Piedmont near Richmond, Virginia, USA: Effects of lithology and well characteristics

    International Nuclear Information System (INIS)

    Harris, Shelley A.; Billmeyer, Ernest R.; Robinson, Michael A.

    2006-01-01

    Radon ( 222 Rn) concentrations in 26 ground water wells of two distinct lithologies in the Piedmont of Virginia were measured to assess variation in ground water radon concentrations (GWRC), to evaluate differences in concentrations related to well characteristics, lithology, and spatial distributions, and to assess the feasibility of predicting GWRC. Wells were sampled in accordance with American Public Health Association Method 7500 Rn-B, with modifications to include a well shaft profile analysis that determined the minimum purge time sufficient to remove the equivalent of one column of water from each well. Statistically significant differences in GWRC were found in the Trssu (1482±1711 pCi/L) and Mpg (7750±5188 pCi/L) lithologies, however, no significant differences were found among GWRC at each well over time. Using multiple regression, 86% of the variability (R 2 ) in the GWRC was explained by the lithology, latitudinal class, and water table elevation of the wells. The GWRC in a majority of the wells studied exceed US Environmental Protection Agency designated maximum contaminant level and AMCL. Results support modifications to sampling procedures and indicate that, in previous studies, variations in GWRC concentrations over time may have been due in part to differences in sampling procedures and not in source water

  10. Testing strong factorial invariance using three-level structural equation modeling

    Directory of Open Access Journals (Sweden)

    Suzanne eJak

    2014-07-01

    Full Text Available Within structural equation modeling, the most prevalent model to investigate measurement bias is the multigroup model. Equal factor loadings and intercepts across groups in a multigroup model represent strong factorial invariance (absence of measurement bias across groups. Although this approach is possible in principle, it is hardly practical when the number of groups is large or when the group size is relatively small. Jak, Oort and Dolan (2013 showed how strong factorial invariance across large numbers of groups can be tested in a multilevel structural equation modeling framework, by treating group as a random instead of a fixed variable. In the present study, this model is extended for use with three-level data. The proposed method is illustrated with an investigation of strong factorial invariance across 156 school classes and 50 schools in a Dutch dyscalculia test, using three-level structural equation modeling.

  11. The control of radioactivity in the working environment in the factories for production of phosphate fertilizers

    International Nuclear Information System (INIS)

    Ajdacic, B.N.; Gnjatovic, S.S.; Vujovic, P.V.

    1980-01-01

    The results of dosimetric control in factories for the production of phosphoric acid and phosphate fertilizers in Serbia, and of the measurement of the total beta radioactivity of samples collected in these factories, are presented. An increase in the radiation dose, even up to 1000 times background, has been found at certain places in the plant. These results serve as a basis for conclusions on the existence, variation and collection of the radioactive component in particular phases of the technological process for the production of phosphate fertilizers. An attempt is made on the basis of the results obtained in three plants to evaluate the degree of danger in the working environment and in the area surrounding the factories and to propose protective measures. (Author)

  12. Assessment of denitrification gaseous end-products in the soil profile under two water table management practices using repeated measures analysis.

    Science.gov (United States)

    Elmi, Abdirashid A; Astatkie, Tess; Madramootoo, Chandra; Gordon, Robert; Burton, David

    2005-01-01

    The denitrification process and nitrous oxide (N2O) production in the soil profile are poorly documented because most research into denitrification has concentrated on the upper soil layer (0-0.15 m). This study, undertaken during the 1999 and 2000 growing seasons, was designed to examine the effects of water table management (WTM), nitrogen (N) application rate, and depth (0.15, 0.30, and 0.45 m) on soil denitrification end-products (N2O and N2) from a corn (Zea mays L.) field. Water table management treatments were free drainage (FD) with open drains and subirrigation (SI) with a target water table depth of 0.6 m. Fertility treatments (ammonium nitrate) were 120 kg N ha(-1) (N120) and 200 kg N ha(-1) (N200). During both growing seasons greater denitrification rates were measured in SI than in FD, particularly in the surface soil (0-0.15 m) and at the intermediate (0.15-0.30 m) soil depths under N200 treatment. Greater denitrification rates under the SI treatment, however, were not accompanied with greater N2O production. The decrease in N2O production under SI was probably caused by a more complete reduction of N2O to N2, which resulted in lower N2O to (N2O + N2) ratios. Denitrification rate, N2O production and N2O to (N2O + N2) ratios were only minimally affected by N treatments, irrespective of sampling date and soil depth. Overall, half of the denitrification occurred at the 0.15- to 0.30- and 0.30- to 0.45-m soil layers, and under SI, regardless of fertility treatment level. Consequently, sampling of the 0- to 0.15-m soil layer alone may not give an accurate estimation of denitrification losses under SI practice.

  13. Real-World Massage Therapy Produces Meaningful Effectiveness Signal for Primary Care Patients with Chronic Low Back Pain: Results of a Repeated Measures Cohort Study.

    Science.gov (United States)

    Elder, William G; Munk, Niki; Love, Margaret M; Bruckner, Geza G; Stewart, Kathryn E; Pearce, Kevin

    2017-07-01

    While efficacy of massage and other nonpharmacological treatments for chronic low back pain is established, stakeholders have called for pragmatic studies of effectiveness in "real-world" primary health care. The Kentucky Pain Research and Outcomes Study evaluated massage impact on pain, disability, and health-related quality of life for primary care patients with chronic low back pain. We report effectiveness and feasibility results, and make comparisons with established minimal clinically important differences. Primary care providers referred eligible patients for 10 massage sessions with community practicing licensed massage therapists. Oswestry Disability Index and SF-36v2 measures obtained at baseline and postintervention at 12 and 24 weeks were analyzed with mixed linear models and Tukey's tests. Additional analyses examined clinically significant improvement and predictive patient characteristics. Of 104 enrolled patients, 85 and 76 completed 12 and 24 weeks of data collection, respectively. Group means improved at 12 weeks for all outcomes and at 24 weeks for SF-36v2's Physical Component Summary and Bodily Pain Domain. Of those with clinically improved disability at 12 weeks, 75% were still clinically improved at 24 weeks ( P  < 0.01). For SF-36v2 Physical and Mental Component Summaries, 55.4% and 43.4%, respectively, showed clinically meaningful improvement at 12 weeks, 46.1% and 30.3% at 24 weeks. For Bodily Pain Domain, 49.4% were clinically improved at 12 weeks, 40% at 24 weeks. Adults older than age 49 years had better pain and disability outcomes than younger adults. Results provide a meaningful signal of massage effect for primary care patients with chronic low back pain and call for further research in practice settings using pragmatic designs with control groups. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. In-Factory Learning - Qualification For The Factory Of The Future

    Science.gov (United States)

    Quint, Fabian; Mura, Katharina; Gorecky, Dominic

    2015-07-01

    The Industry 4.0 vision anticipates that internet technologies will find their way into future factories replacing traditional components by dynamic and intelligent cyber-physical systems (CPS) that combine the physical objects with their digital representation. Reducing the gap between the real and digital world makes the factory environment more flexible, more adaptive, but also more complex for the human workers. Future workers require interdisciplinary competencies from engineering, information technology, and computer science in order to understand and manage the diverse interrelations between physical objects and their digital counterpart. This paper proposes a mixed-reality based learning environment, which combines physical objects and visualisation of digital content via Augmented Reality. It uses reality-based interaction in order to make the dynamic interrelations between real and digital factory visible and tangible. We argue that our learning system does not work as a stand-alone solution, but should fit into existing academic and advanced training curricula.

  15. Effects of two hospital bed design features on physical demands and usability during brake engagement and patient transportation: a repeated measures experimental study.

    Science.gov (United States)

    Kim, Sunwook; Barker, Linsey M; Jia, Bochen; Agnew, Michael J; Nussbaum, Maury A

    2009-03-01

    Work-related musculoskeletal disorders (WMSDs) are prevalent among healthcare workers worldwide. While existing research has focused on patient-handling techniques during activities which require direct patient contact (e.g., patient transfer), nursing tasks also involve other patient-handling activities, such as engaging bed brakes and transporting patients in beds, which could render healthcare workers at risk of developing WMSDs. Effectiveness of hospital bed design features (brake pedal location and steering-assistance) was evaluated in terms of physical demands and usability during brake engagement and patient transportation tasks. Two laboratory-based studies were conducted. In simulated brake engagement tasks, three brake pedal locations (head-end vs. foot-end vs. side of a bed) and two hands conditions (hands-free vs. hands-occupied) were manipulated. Additionally, both in-room and corridor patient transportation tasks were simulated, in which activation of steering-assistance features (5th wheel and/or front wheel caster lock) and two patient masses were manipulated. Nine novice participants were recruited from the local student population and community for each study. During brake engagement, trunk flexion angle, task completion time, and questionnaires were used to quantify postural comfort and usability. For patient transportation, dependent measures were hand forces and questionnaire responses. Brake pedal locations and steering-assistance features in hospital beds had significant effects on physical demands and usability during brake engagement and patient transportation tasks. Specifically, a brake pedal at the head-end of a bed increased trunk flexion by 74-224% and completion time by 53-74%, compared to other pedal locations. Participants reported greater overall perceived difficulty and less postural comfort with the brake pedal at the head-end. During in-room transportation, participants generally reported "Neither Low nor High" physical demands

  16. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  17. The Tau-Charm Factory in the ERA of B-Factories and CESR

    International Nuclear Information System (INIS)

    Beers, L.V.; Perl, M.L.

    1994-10-01

    This paper is a collection of presentations made at a conference on tau-charm factories, held at the Stanford Linear Accelerator Center and Stanford University on August 15-16, 1994. The papers presented summarize the physics which can be learned from such a facility, the advantages it would present over planned B-factories and large centers such as CESR, and the types of decay modes which could be observed. More detailed studies of tau physics are opened up, as well as charmonium and charmed systems. Seperate presentations to the proceedings are indexed individually into the database

  18. Do code of conduct audits improve chemical safety in garment factories? Lessons on corporate social responsibility in the supply chain from Fair Wear Foundation.

    Science.gov (United States)

    Lindholm, Henrik; Egels-Zandén, Niklas; Rudén, Christina

    2016-10-01

    In managing chemical risks to the environment and human health in supply chains, voluntary corporate social responsibility (CSR) measures, such as auditing code of conduct compliance, play an important role. To examine how well suppliers' chemical health and safety performance complies with buyers' CSR policies and whether audited factories improve their performance. CSR audits (n = 288) of garment factories conducted by Fair Wear Foundation (FWF), an independent non-profit organization, were analyzed using descriptive statistics and statistical modeling. Forty-three per cent of factories did not comply with the FWF code of conduct, i.e. received remarks on chemical safety. Only among factories audited 10 or more times was there a significant increase in the number of factories receiving no remarks. Compliance with chemical safety requirements in garment supply chains is low and auditing is statistically correlated with improvements only at factories that have undergone numerous audits.

  19. Do code of conduct audits improve chemical safety in garment factories? Lessons on corporate social responsibility in the supply chain from Fair Wear Foundation

    Science.gov (United States)

    2016-01-01

    Background In managing chemical risks to the environment and human health in supply chains, voluntary corporate social responsibility (CSR) measures, such as auditing code of conduct compliance, play an important role. Objectives To examine how well suppliers’ chemical health and safety performance complies with buyers’ CSR policies and whether audited factories improve their performance. Methods CSR audits (n = 288) of garment factories conducted by Fair Wear Foundation (FWF), an independent non-profit organization, were analyzed using descriptive statistics and statistical modeling. Results Forty-three per cent of factories did not comply with the FWF code of conduct, i.e. received remarks on chemical safety. Only among factories audited 10 or more times was there a significant increase in the number of factories receiving no remarks. Conclusions Compliance with chemical safety requirements in garment supply chains is low and auditing is statistically correlated with improvements only at factories that have undergone numerous audits. PMID:27611103

  20. Physics with the KLOE2 experiment at the φ factory

    International Nuclear Information System (INIS)

    Bloise, C.; Gauzzi, P.

    2009-01-01

    We report on the most debated issues which experimentation at the φ factory can really shed light on with a short-term program of measurements. Recent, very promising improvements in the lattice-QCD calculations call for new precision measurements in the Kaon sector to obtain more stringent results on CKM Unitarity and Lepton Flavour Universality. Neutral Kaon Interferometry can probe Discrete Symmetries, but also Quantum Mechanics at the Planck scale. Current limits obtained by KLOE can be overcome by both, the increase in statistics, and the upgrade of the tracking system with an inner GEM chamber for improving vertex resolution near the beam interaction region. One possible solution to the Dark Mass problem, allowing also to interpret the positron excess measured by the satellite Payload experiment PAMELA, suggests a '' dark '' sector that can really be constrained by the experiments at the Kaon and B-Factories. Low energy QCD phenomenology can receive an important contribution from the new measurements of radiative and non-leptonic decays of K, eta and eta' mesons. Finally, important results on the physics in the continuum can be achieved by new measurements of the hadronic cross section and the study of gamma-gamma processes. Improvements on hadronic cross section at low energy are needed to understand the 3-sigma effect on (g-2) μ and for precision determination of alpha em at the TeV scale while the analysis of the gamma-gamma sample impacts scalar spectroscopy and the underlying physics but also the light-by-light hadronic contribution to (g-2) μ . (authors)