WorldWideScience

Sample records for repeated measures examining

  1. Intra-examiner repeatability and agreement in accommodative response measurements.

    Science.gov (United States)

    Antona, B; Sanchez, I; Barrio, A; Barra, F; Gonzalez, E

    2009-11-01

    Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods. The AR of the right eye at one accommodative demand of 2.50 D (40 cm) was measured on two separate occasions in 61 visually normal subjects of mean age 19.7 years (range 18-32 years). The intraexaminer repeatability of the tests, and agreement between them, were estimated by the Bland-Altman method. We determined mean differences (MD) and the 95% limits of agreement [coefficient of repeatability (COR) and coefficient of agreement (COA)]. Nott retinoscopy and BCC offered the best repeatability, showing the lowest MD and narrowest 95% interval of agreement (Nott: -0.10 +/- 0.66 D, BCC: -0.05 +/- 0.75 D). The 95% limits of agreement for the four techniques were similar (COA = +/- 0.92 to +/-1.00 D) yet clinically significant, according to the expected values of the AR. The two dynamic retinoscopy techniques (Nott and MEM) had a better agreement (COA = +/-0.64 D) although this COA must be interpreted in the context of the low MEM repeatability (COR = +/-0.98 D). The best method of assessing AR was Nott retinoscopy. The BCC technique was also repeatable, and both are recommended as suitable methods for clinical use. Despite better agreement between MEM and Nott, agreement among the remaining methods was poor such that their interchangeable use in clinical practice is not recommended.

  2. Repeatability and reproducibility of decisions by latent fingerprint examiners.

    Directory of Open Access Journals (Sweden)

    Bradford T Ulery

    Full Text Available The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as "difficult" than for "easy" or "moderate" comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4; 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization. Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases.

  3. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  4. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  5. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.; Maity, A.; Mammen, E.; Yu, K.

    2009-01-01

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements

  6. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  7. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Near-Peer Teaching in Paramedic Education: A Repeated Measures Design

    Science.gov (United States)

    Williams, Brett; Nguyen, David

    2017-01-01

    The transition of the Australian paramedic discipline from vocation education and training to the higher education sector has seen a sharp rise in interest in near-peer teaching (NPT). The objective of this study was to examine satisfaction levels of NPT over one academic semester among undergraduate paramedic students. A repeated measured design…

  9. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  10. Methods for analysing cardiovascular studies with repeated measures

    NARCIS (Netherlands)

    Cleophas, T. J.; Zwinderman, A. H.; van Ouwerkerk, B. M.

    2009-01-01

    Background. Repeated measurements in a single subject are generally more similar than unrepeated measurements in different subjects. Unrepeated analyses of repeated data cause underestimation of the treatment effects. Objective. To review methods adequate for the analysis of cardiovascular studies

  11. Comparability and repeatability of three commonly used methods for measuring endurance capacity.

    Science.gov (United States)

    Baxter-Gilbert, James; Mühlenhaupt, Max; Whiting, Martin J

    2017-12-01

    Measures of endurance (time to exhaustion) have been used to address a wide range of questions in ecomorphological and physiological research, as well as being used as a proxy for survival and fitness. Swimming, stationary (circular) track running, and treadmill running are all commonly used methods for measuring endurance. Despite the use of these methods across a broad range of taxa, how comparable these methods are to one another, and whether they are biologically relevant, is rarely examined. We used Australian water dragons (Intellagama lesueurii), a species that is morphologically adept at climbing, swimming, and running, to compare these three methods of endurance and examined if there is repeatability within and between trial methods. We found that time to exhaustion was not highly repeatable within a method, suggesting that single measures or a mean time to exhaustion across trials are not appropriate. Furthermore, we compared mean maximal endurance times among the three methods, and found that the two running methods (i.e., stationary track and treadmill) were similar, but swimming was distinctly different, resulting in lower mean maximal endurance times. Finally, an individual's endurance rank was not repeatable across methods, suggesting that the three endurance trial methods are not providing similar information about an individual's performance capacity. Overall, these results highlight the need to carefully match a measure of performance capacity with the study species and the research questions being asked so that the methods being used are behaviorally, ecologically, and physiologically relevant. © 2018 Wiley Periodicals, Inc.

  12. [Computer optical topography: a study of the repeatability of the results of human body model examination].

    Science.gov (United States)

    Sarnadskiĭ, V N

    2007-01-01

    The problem of repeatability of the results of examination of a plastic human body model is considered. The model was examined in 7 positions using an optical topograph for kyphosis diagnosis. The examination was performed under television camera monitoring. It was shown that variation of the model position in the camera view affected the repeatability of the results of topographic examination, especially if the model-to-camera distance was changed. A study of the repeatability of the results of optical topographic examination can help to increase the reliability of the topographic method, which is widely used for medical screening of children and adolescents.

  13. Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements.

    Science.gov (United States)

    Preis, Sarah Rosner; Spiegelman, Donna; Zhao, Barbara Bojuan; Moshfegh, Alanna; Baer, David J; Willett, Walter C

    2011-03-15

    Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (ρ) and deattenuation factor (λ), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure to account for within-person variation in biomarkers can exaggerate correlated errors between FFQs and 24-hour diet recalls. For 2 validation studies, ρ and λ were calculated for total energy and protein density. In the Automated Multiple-Pass Method Validation Study (n=471), doubly labeled water (DLW) and urinary nitrogen (UN) were measured twice in 52 adults approximately 16 months apart (2002-2003), yielding intraclass correlation coefficients of 0.43 for energy (DLW) and 0.54 for protein density (UN/DLW). The deattenuated correlation coefficient for protein density was 0.51 for correlation between the FFQ and the 24-hour diet recall and 0.49 for correlation between the FFQ and the biomarker. Use of repeat-biomarker measurement error models resulted in a ρ of 0.42. These models were similarly applied to the Observing Protein and Energy Nutrition Study (1999-2000). In conclusion, within-person variation in biomarkers can be substantial, and to adequately assess the impact of correlated subject-specific error, this variation should be assessed in validation studies of FFQs. © The Author 2011. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved.

  14. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  15. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  16. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  17. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  18. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  19. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  20. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  1. Validation of Diagnostic Imaging Based on Repeat Examinations. An Image Interpretation Model

    International Nuclear Information System (INIS)

    Isberg, B.; Jorulf, H.; Thorstensen, Oe.

    2004-01-01

    Purpose: To develop an interpretation model, based on repeatedly acquired images, aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. Material and Methods: A theoretical model is proposed. The studied population consists of subjects that develop focal lesions which increase in size in organs of interest during the study period. The imaging modality produces images that can be re-interpreted with high precision, e.g. conventional radiography, computed tomography, and magnetic resonance imaging. At least four repeat examinations are carried out. Results: The interpretation is performed in four or five steps: 1. Independent readers interpret the examinations chronologically without access to previous or subsequent films. 2. Lesions found on images at the last examination are included in the analysis, with interpretation in consensus. 3. By concurrent back-reading in consensus, the lesions are identified on previous images until they are so small that even in retrospect they are undetectable. The earliest examination at which included lesions appear is recorded, and the lesions are verified by their growth (imaging reference standard). Lesion size and other characteristics may be recorded. 4. Records made at step 1 are corrected to those of steps 2 and 3. False positives are recorded. 5. (Optional) Lesion type is confirmed by another diagnostic test. Conclusion: Applied on subjects with progressive disease, the proposed image interpretation model may improve assessments of technical efficacy and diagnostic accuracy in the detection of small focal lesions. The model may provide an accurate imaging reference standard as well as repeated detection rates and false-positive rates for tested imaging modalities. However, potential review bias necessitates a strict protocol

  2. The effect of repeated applanation on subsequent IOP measurements.

    Science.gov (United States)

    AlMubrad, Turki M; Ogbuehi, Kelechi C

    2008-11-01

    In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (pcontact tonometer in both sessions. These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.

  3. Repeatability of Lucas chamber measurements; Powtarzalnosc pomiarow za pomoca komory Lucasa

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.

    1997-12-31

    Results of investigations concerning the repeatability of the measurements carried out with Lucas chamber are presented in the report. The Lucas chamber is used for determination of radon concentration in air, and the Lucas chamber itself is measured in a laboratory stand. The repeatability of measurements is {+-}5.4% relative. The error due to instability of measuring channel gain is estimated to be 2-3% relative. (author). 5 refs, 17 figs, 5 tabs.

  4. REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

    Energy Technology Data Exchange (ETDEWEB)

    Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa [Spitzer Science Center, California Institute of Technology, 1200 E California Boulevard, Mail Code 314-6, Pasadena, CA 91125 (United States); Buzasi, Derek [Department of Chemistry and Physics, Florida Gulf Coast University, Fort Myers, FL 33965 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Diamond-Lowe, Hannah; Stevenson, Kevin B. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S Ellis Avenue, Chicago, IL 60637 (United States); Evans, Thomas M. [School of Physics, University of Exeter, EX4 4QL Exeter (United Kingdom); Morello, G. [Department of Physics and Astronomy, University College London, Gower Street, WC1 E6BT (United Kingdom); Wong, Ian, E-mail: ingalls@ipac.caltech.edu [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-08-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble,  5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

  5. Use of the Counseling Center Assessment of Psychological Symptoms 62 (CCAPS-62) as a Repeated Measure

    Science.gov (United States)

    Ghosh, Arpita; Rieder Bennett, Sara; Martin, Juanita K.

    2018-01-01

    The purpose of this initial, exploratory study was to examine the utility of the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62) as a repeated measure tool at one university counseling center. This study investigated whether clients engaged in individual counseling changed in symptomology while in treatment and when (e.g.,…

  6. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  7. High precision measurement of the micro-imaging system to check repeatability of precision

    International Nuclear Information System (INIS)

    Cheng Lin; Song Li; Ma Chuntao; Luo Hongxin; Wang Jie

    2010-01-01

    The beamlines slits of Shanghai Synchrotron Radiation Facility (SSRF) are required to have a repeatability of better than 1 μm. Before the slits installation, the off-line and/or on-line repeatability measurements must be conducted. A machine vision measuring system based on high resolution CCD and adjustable high magnification lens was used in this regard. A multi-level filtering method was used to treat the imaging data. After image binarization, the imaging noises were depressed effectively by using of algebraic mean filtering, statistics median filtering,and the least square filtering. Using the subtracted image between the images before and after slit movement, an average displacement of slit blades could be obtained, and the repeatability of slit could be measured, with a resolution of 0.3 μm of the measurement system. The experimental results show that this measurement system meets the requirements for non-contact measurements to the repeatability of slits. (authors)

  8. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Gietema, Hester A.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands); Isgum, Ivana; Mol, Christian P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Zanen, Pieter [University Medical Center Utrecht, Pulmonology, Utrecht (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Centre, Radiology, Nijmegen (Netherlands); University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands)

    2012-12-15

    To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3 months. Inspiratory and expiratory low-dose CT was obtained using breath hold instructions. CT air trapping was defined as the percentage of voxels in expiratory CT with an attenuation below -856 HU (EXP{sub -856}) and the expiratory to inspiratory ratio of mean lung density (E/I-ratio{sub MLD}). Variation was determined using limits of agreement, defined as 1.96 times the standard deviation of the mean difference. The effect of both lung volume correction and breath hold reproducibility was determined. The limits of agreement for uncorrected CT air trapping measurements were -15.0 to 11.7 % (EXP{sub -856}) and -9.8 to 8.0 % (E/I-ratio{sub MLD}). Good breath hold reproducibility significantly narrowed the limits for EXP{sub -856} (-10.7 to 7.5 %, P = 0.002), but not for E/I-ratio{sub MLD} (-9.2 to 7.9 %, P = 0.75). Statistical lung volume correction did not improve the limits for EXP{sub -856} (-12.5 to 8.8 %, P = 0.12) and E/I-ratio{sub MLD} (-7.5 to 5.8 %, P = 0.17). Quantitative air trapping measures on low-dose CT of heavy smokers show considerable variation on repeat CT examinations, regardless of lung volume correction or reproducible breath holds. (orig.)

  9. Repeatability of Objective Measurements of Linear Udder and Body ...

    African Journals Online (AJOL)

    The objective of this study was to estimates the repeatability of objective measurements on linear udder and body conformation traits and to evaluate the objectivity of the measurements in Friesian x Bunaji cows. Data from 50 (F1) Frisian X Bunaji cows collected between 2007 and 2008 at the Dairy Research Farm of the ...

  10. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  11. Analyzing repeated measures data on individuals nested within groups: accounting for dynamic group effects.

    Science.gov (United States)

    Bauer, Daniel J; Gottfredson, Nisha C; Dean, Danielle; Zucker, Robert A

    2013-03-01

    Researchers commonly collect repeated measures on individuals nested within groups such as students within schools, patients within treatment groups, or siblings within families. Often, it is most appropriate to conceptualize such groups as dynamic entities, potentially undergoing stochastic structural and/or functional changes over time. For instance, as a student progresses through school, more senior students matriculate while more junior students enroll, administrators and teachers may turn over, and curricular changes may be introduced. What it means to be a student within that school may thus differ from 1 year to the next. This article demonstrates how to use multilevel linear models to recover time-varying group effects when analyzing repeated measures data on individuals nested within groups that evolve over time. Two examples are provided. The 1st example examines school effects on the science achievement trajectories of students, allowing for changes in school effects over time. The 2nd example concerns dynamic family effects on individual trajectories of externalizing behavior and depression. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  12. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    International Nuclear Information System (INIS)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-01-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of [ 3 H]Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in [14C]iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress [an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures], although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results

  13. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  14. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  15. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  16. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  17. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  18. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions.

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  19. Estimators for longitudinal latent exposure models: examining measurement model assumptions.

    Science.gov (United States)

    Sánchez, Brisa N; Kim, Sehee; Sammel, Mary D

    2017-06-15

    Latent variable (LV) models are increasingly being used in environmental epidemiology as a way to summarize multiple environmental exposures and thus minimize statistical concerns that arise in multiple regression. LV models may be especially useful when multivariate exposures are collected repeatedly over time. LV models can accommodate a variety of assumptions but, at the same time, present the user with many choices for model specification particularly in the case of exposure data collected repeatedly over time. For instance, the user could assume conditional independence of observed exposure biomarkers given the latent exposure and, in the case of longitudinal latent exposure variables, time invariance of the measurement model. Choosing which assumptions to relax is not always straightforward. We were motivated by a study of prenatal lead exposure and mental development, where assumptions of the measurement model for the time-changing longitudinal exposure have appreciable impact on (maximum-likelihood) inferences about the health effects of lead exposure. Although we were not particularly interested in characterizing the change of the LV itself, imposing a longitudinal LV structure on the repeated multivariate exposure measures could result in high efficiency gains for the exposure-disease association. We examine the biases of maximum likelihood estimators when assumptions about the measurement model for the longitudinal latent exposure variable are violated. We adapt existing instrumental variable estimators to the case of longitudinal exposures and propose them as an alternative to estimate the health effects of a time-changing latent predictor. We show that instrumental variable estimators remain unbiased for a wide range of data generating models and have advantages in terms of mean squared error. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  1. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    Science.gov (United States)

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  2. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  3. Convergence of repeated quantum nondemolition measurements and wave-function collapse

    International Nuclear Information System (INIS)

    Bauer, Michel; Bernard, Denis

    2011-01-01

    Motivated by recent experiments on quantum trapped fields, we give a rigorous proof that repeated indirect quantum nondemolition (QND) measurements converge to the collapse of the wave function as predicted by the postulates of quantum mechanics for direct measurements. We also relate the rate of convergence toward the collapsed wave function to the relative entropy of each indirect measurement, a result which makes contact with information theory.

  4. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...... to sphericity assumptions, use of F tests and the Greenhouse-Geisser and Huynh-Feldt adjustments to compensate for deviations from sphericity. During a recent implementation of such methods in the R language, the general structure of such transformations was reconsidered, leading to a flexible specification...

  5. Joint modelling of repeated measurement and time-to-event data: an introductory tutorial.

    Science.gov (United States)

    Asar, Özgür; Ritchie, James; Kalra, Philip A; Diggle, Peter J

    2015-02-01

    The term 'joint modelling' is used in the statistical literature to refer to methods for simultaneously analysing longitudinal measurement outcomes, also called repeated measurement data, and time-to-event outcomes, also called survival data. A typical example from nephrology is a study in which the data from each participant consist of repeated estimated glomerular filtration rate (eGFR) measurements and time to initiation of renal replacement therapy (RRT). Joint models typically combine linear mixed effects models for repeated measurements and Cox models for censored survival outcomes. Our aim in this paper is to present an introductory tutorial on joint modelling methods, with a case study in nephrology. We describe the development of the joint modelling framework and compare the results with those obtained by the more widely used approaches of conducting separate analyses of the repeated measurements and survival times based on a linear mixed effects model and a Cox model, respectively. Our case study concerns a data set from the Chronic Renal Insufficiency Standards Implementation Study (CRISIS). We also provide details of our open-source software implementation to allow others to replicate and/or modify our analysis. The results for the conventional linear mixed effects model and the longitudinal component of the joint models were found to be similar. However, there were considerable differences between the results for the Cox model with time-varying covariate and the time-to-event component of the joint model. For example, the relationship between kidney function as measured by eGFR and the hazard for initiation of RRT was significantly underestimated by the Cox model that treats eGFR as a time-varying covariate, because the Cox model does not take measurement error in eGFR into account. Joint models should be preferred for simultaneous analyses of repeated measurement and survival data, especially when the former is measured with error and the association

  6. Study of problems associated with the ultrasonic examination of repeatedly repaired austenitic stainless steel welds

    International Nuclear Information System (INIS)

    Subbaratnam, R.; Palaniappan, M.; Baskaran, A.; Chandramohan, R.

    1994-01-01

    In recent years the ultrasonic examination of austenitic stainless steel weldments has gained increased importance as an NDE technique for the volumetric examination in the nuclear power plant construction and other industries. A study has been undertaken to evaluate the effects of multiple repairs on austenitic stainless steel weldments, for the successful ultrasonic examination. The test welds have been subjected to repeated welding cycles and the ultrasonic parameters including the defect characterization have been evaluated for analysis. The paper discusses the approach followed, analysis, results obtained and the recommendations based on the above. 1 fig., 2 tabs

  7. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  8. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  9. Analysis of repeated measurement data in the clinical trials

    Science.gov (United States)

    Singh, Vineeta; Rana, Rakesh Kumar; Singhal, Richa

    2013-01-01

    Statistics is an integral part of Clinical Trials. Elements of statistics span Clinical Trial design, data monitoring, analyses and reporting. A solid understanding of statistical concepts by clinicians improves the comprehension and the resulting quality of Clinical Trials. In biomedical research it has been seen that researcher frequently use t-test and ANOVA to compare means between the groups of interest irrespective of the nature of the data. In Clinical Trials we record the data on the patients more than two times. In such a situation using the standard ANOVA procedures is not appropriate as it does not consider dependencies between observations within subjects in the analysis. To deal with such types of study data Repeated Measure ANOVA should be used. In this article the application of One-way Repeated Measure ANOVA has been demonstrated by using the software SPSS (Statistical Package for Social Sciences) Version 15.0 on the data collected at four time points 0 day, 15th day, 30th day, and 45th day of multicentre clinical trial conducted on Pandu Roga (~Iron Deficiency Anemia) with an Ayurvedic formulation Dhatrilauha. PMID:23930038

  10. Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

    OpenAIRE

    Ruiz-Belda, Clara; Piñero, David P.; Ruiz Fortes, Pedro; Soto-Negro, Roberto; Moya, Myriam; Pérez Cambrodí, Rafael J.; Artola, Alberto

    2016-01-01

    Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the C...

  11. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  12. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    Science.gov (United States)

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  13. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Science.gov (United States)

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  14. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  15. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  16. Estimation of breast doses and breast cancer risk associated with repeated fluoroscopic chest examinations of women with tuberculosis

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Rosenstein, M.; Trout, E.D.

    1978-01-01

    A methodology is presented to estimate cumulative breast dose and breast cancer risk for women exposed to repeated fluoroscopic chest examinations during air collapse therapy for pulmonary tuberculosis. Medical record abstraction, physician interview, patient contact, machine exposure measurements, and absorbed dose computations were combined to estimate average breast doses for 1047 Massachusetts women who were treated between 1930 and 1954. The methodology presented considers breast size and composition, patient orientation, x-ray field size and location, beam quality, type of examination, machine exposure rate, and exposure time during fluoroscopic examinations. The best estimate for the risk of radiation-induced cancer for the women living longer than 10 years after initial fluoroscopic exposure is 6.2 excess breast cancers per million woman-year-rad with 90% confidence limits of 2.8 and 10.7 cancers/10 6 WY-rad. When breast cancer risk is considered as a function of absorbed dose in the breast, instead of as a function of the number of fluoroscopic examinations, a linear dose--response relationship over the range of estimated doses is consistent with the data. However, because of the uncertainty due to small-sample variability and because of the wide range of assumptions regarding certain fluoroscopy conditions, other dose--response relationships are compatible with the data

  17. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  18. Unitarity, Feedback, Interactions - Dynamics Emergent from Repeated Measurements

    Science.gov (United States)

    Corona Ugalde, Paulina; Altamirano, Natacha; Mann, Robert; Zych, Magdalena

    Modern measurement theory dispenses with the description of a measurement as a projection. Rather, the measurement is understood as an operation, whereby the system's final state is determined by an action of a completely positive trace non-increasing map and the outcomes are described by linear operators on the system, distributed according to a positive-operator valued measure (POVM). The POVM approach unifies the theory of measurements with a general description of dynamics, the theory of open quantum systems. Engineering a particular measurement and engineering a particular dynamics for the system are thus two complementary aspects of the same conceptual framework. This correspondence is directly applied in quantum simulations and quantum control theory . With this motivation, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence. For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions. The simple framework used in the present study can find applications in devising novel quantum control protocols, or quantum simulations.

  19. Repeatability of measures of inflammatory cell number in bronchial biopsies in atopic asthma

    NARCIS (Netherlands)

    Sont, J. K.; Willems, L. N.; Evertse, C. E.; Hooijer, R.; Sterk, P. J.; van Krieken, J. H.

    1997-01-01

    Airway pathology is increasingly considered to be a major outcome in asthma research. The aim of this study was to examine the intra-observer, within-section and between-biopsy repeatability, together with the implications for statistical power of a computerized quantitative analysis of inflammatory

  20. Discontinuous Patterns of Cigarette Smoking From Ages 18 to 50 in the United States: A Repeated-Measures Latent Class Analysis.

    Science.gov (United States)

    Terry-McElrath, Yvonne M; O'Malley, Patrick M; Johnston, Lloyd D

    2017-12-13

    Effective cigarette smoking prevention and intervention programming is enhanced by accurate understanding of developmental smoking pathways across the life span. This study investigated within-person patterns of cigarette smoking from ages 18 to 50 among a US national sample of high school graduates, focusing on identifying ages of particular importance for smoking involvement change. Using data from approximately 15,000 individuals participating in the longitudinal Monitoring the Future study, trichotomous measures of past 30-day smoking obtained at 11 time points were modeled using repeated-measures latent class analyses. Sex differences in latent class structure and membership were examined. Twelve latent classes were identified: three characterized by consistent smoking patterns across age (no smoking; smoking developing effective smoking prevention and intervention programming. This study examined cigarette smoking among a national longitudinal US sample of high school graduates from ages 18 to 50 and identified distinct latent classes characterized by patterns of movement between no cigarette use, light-to-moderate smoking, and the conventional definition of heavy smoking at 11 time points via repeated-measures latent class analysis. Membership probabilities for each smoking class were estimated, and critical ages of susceptibility to change in smoking behaviors were identified. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  2. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    Science.gov (United States)

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations

  3. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    International Nuclear Information System (INIS)

    Kroner, E; Arzt, E; Maboudian, R

    2009-01-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  4. Repeatable aversion across threat types is linked with life-history traits but is dependent on how aversion is measured.

    Science.gov (United States)

    Davidson, Gabrielle L; Reichert, Michael S; Crane, Jodie M S; O'Shea, William; Quinn, John L

    2018-02-01

    Personality research suggests that individual differences in risk aversion may be explained by links with life-history variation. However, few empirical studies examine whether repeatable differences in risk avoidance behaviour covary with life-history traits among individuals in natural populations, or how these links vary depending on the context and the way risk aversion is measured. We measured two different risk avoidance behaviours (latency to enter the nest and inspection time) in wild great tits ( Parus major ) in two different contexts-response to a novel object and to a predator cue placed at the nest-box during incubation---and related these behaviours to female reproductive success and condition. Females responded equally strongly to both stimuli, and although both behaviours were repeatable, they did not correlate. Latency to enter was negatively related to body condition and the number of offspring fledged. By contrast, inspection time was directly explained by whether incubating females had been flushed from the nest before the trial began. Thus, our inferences on the relationship between risk aversion and fitness depend on how risk aversion was measured. Our results highlight the limitations of drawing conclusions about the relevance of single measures of a personality trait such as risk aversion.

  5. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  6. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  7. On summary measure analysis of linear trend repeated measures data: performance comparison with two competing methods.

    Science.gov (United States)

    Vossoughi, Mehrdad; Ayatollahi, S M T; Towhidi, Mina; Ketabchi, Farzaneh

    2012-03-22

    The summary measure approach (SMA) is sometimes the only applicable tool for the analysis of repeated measurements in medical research, especially when the number of measurements is relatively large. This study aimed to describe techniques based on summary measures for the analysis of linear trend repeated measures data and then to compare performances of SMA, linear mixed model (LMM), and unstructured multivariate approach (UMA). Practical guidelines based on the least squares regression slope and mean of response over time for each subject were provided to test time, group, and interaction effects. Through Monte Carlo simulation studies, the efficacy of SMA vs. LMM and traditional UMA, under different types of covariance structures, was illustrated. All the methods were also employed to analyze two real data examples. Based on the simulation and example results, it was found that the SMA completely dominated the traditional UMA and performed convincingly close to the best-fitting LMM in testing all the effects. However, the LMM was not often robust and led to non-sensible results when the covariance structure for errors was misspecified. The results emphasized discarding the UMA which often yielded extremely conservative inferences as to such data. It was shown that summary measure is a simple, safe and powerful approach in which the loss of efficiency compared to the best-fitting LMM was generally negligible. The SMA is recommended as the first choice to reliably analyze the linear trend data with a moderate to large number of measurements and/or small to moderate sample sizes.

  8. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  9. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and

  10. Formatting data files for repeated-measures analyses in SPSS: Using the Aggregate and Restructure procedures

    Directory of Open Access Journals (Sweden)

    Gyslain Giguère

    2006-03-01

    Full Text Available In this tutorial, we demonstrate how to use the Aggregate and Restructure procedures available in SPSS (versions 11 and up to prepare data files for repeated-measures analyses. In the first two sections of the tutorial, we briefly describe the Aggregate and Restructure procedures. In the final section, we present an example in which the data from a fictional lexical decision task are prepared for analysis using a mixed-design ANOVA. The tutorial demonstrates that the presented method is the most efficient way to prepare data for repeated-measures analyses in SPSS.

  11. Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.

    Science.gov (United States)

    Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E

    2018-01-01

    The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established

  12. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  13. Validation of Repeated Endothelial Function Measurements Using EndoPAT in Stroke

    DEFF Research Database (Denmark)

    Hansen, Aina S; Butt, Jawad H; Holm-Yildiz, Sonja

    2017-01-01

    BACKGROUND: Decreased endothelial function (EF) may be a prognostic marker for stroke. Measuring pharmacological effects on EF may be of interest in the development of personalized medicine for stroke prevention. In this study, we assessed the reliability of repeated EF measurements using a pulse......%, mean age 35.85 ± 3.47 years) and 21 stroke patients (men 52%, mean age 66.38 ± 2.85 years, and mean NIHSS 4.09 ± 0.53) under standardized conditions. EF was measured as the reactive hyperemia index (RHI), logarithm of RHI (lnRHI), and Framingham RHI (fRHI). Measurements were separated by 1.5 and 24 h...

  14. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  15. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  16. Inter-observer and inter-examination variability of manual vertebral bone attenuation measurements on computed tomography

    International Nuclear Information System (INIS)

    Pompe, Esther; Lammers, Jan-Willem J.; Jong, Pim A. de; Jong, Werner U. de; Takx, Richard A.P.; Eikendal, Anouk L.M.; Willemink, Martin J.; Mohamed Hoesein, Firdaus A.A.; Oudkerk, Matthijs; Budde, Ricardo P.J.

    2016-01-01

    To determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT). Three hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis. Inter-examination reliability was excellent with an ICC of 0.92 (p < 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification. Vertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT. (orig.)

  17. Repeated passive stretching : Acute effect on the passive muscle moment and extensibility of short hamstrings

    NARCIS (Netherlands)

    Halbertsma, JPK; Mulder, [No Value; Goeken, LNH; Eisma, WH; Mulder, I.; Göeken, L.N.

    Objective: To examine the response of short hamstring muscles to repeated passive stretching. Design: A repeated measures design. Setting: A university laboratory for human movement analysis in a department of rehabilitation. Subjects: Students (7 men, 10 women) from the Department of Human Movement

  18. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between......, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity....

  19. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind

  20. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  1. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate b...

  2. Analyzing Repeated Measures Marginal Models on Sample Surveys with Resampling Methods

    Directory of Open Access Journals (Sweden)

    James D. Knoke

    2005-12-01

    Full Text Available Packaged statistical software for analyzing categorical, repeated measures marginal models on sample survey data with binary covariates does not appear to be available. Consequently, this report describes a customized SAS program which accomplishes such an analysis on survey data with jackknifed replicate weights for which the primary sampling unit information has been suppressed for respondent confidentiality. First, the program employs the Macro Language and the Output Delivery System (ODS to estimate the means and covariances of indicator variables for the response variables, taking the design into account. Then, it uses PROC CATMOD and ODS, ignoring the survey design, to obtain the design matrix and hypothesis test specifications. Finally, it enters these results into another run of CATMOD, which performs automated direct input of the survey design specifications and accomplishes the appropriate analysis. This customized SAS program can be employed, with minor editing, to analyze general categorical, repeated measures marginal models on sample surveys with replicate weights. Finally, the results of our analysis accounting for the survey design are compared to the results of two alternate analyses of the same data. This comparison confirms that such alternate analyses, which do not properly account for the design, do not produce useful results.

  3. Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination

    Directory of Open Access Journals (Sweden)

    Rashad MA

    2012-12-01

    Full Text Available Mohammad A RashadOphthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, EgyptPurpose: To evaluate the success rate of a modified bleb needling technique in eyes with previous glaucoma surgery that had elevated intraocular pressure.Methods: A retrospective study of 24 eyes of 24 patients that underwent repeated bleb needling performed for failing and failed blebs on slit lamp with 5-fluorouracil (5-FU injections on demand. This was performed after gonioscopic examination to define levels of filtration block.Results: There was significant reduction of mean IOP from 36.91 mmHg to 14.73 mmHg at the final follow-up (P < 0.001. The overall success rate was 92%.Conclusion: Repeated needling with adjunctive 5-FU proved a highly effective, safe alternative to revive filtration surgery rather than another medication or surgery.Keywords: bleb, failure, 5-FU, needling, gonioscopy

  4. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Phypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  5. Repeatability study of replicate crash tests: A signal analysis approach.

    Science.gov (United States)

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test

  6. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  7. Repeated assessment of orthotopic glioma pO2 by multi-site EPR oximetry: A technique with the potential to guide therapeutic optimization by repeated measurements of oxygen

    Science.gov (United States)

    Khan, Nadeem; Mupparaju, Sriram; Hou, Huagang; Williams, Benjamin B.; Swartz, Harold

    2011-01-01

    Tumor hypoxia plays a vital role in therapeutic resistance. Consequently, measurements of tumor pO2 could be used to optimize the outcome of oxygen-dependent therapies, such as, chemoradiation. However, the potential optimizations are restricted by the lack of methods to repeatedly and quantitatively assess tumor pO2 during therapies, particularly in gliomas. We describe the procedures for repeated measurements of orthotopic glioma pO2 by multi-site electron paramagnetic resonance (EPR) oximetry. This oximetry approach provides simultaneous measurements of pO2 at more than one site in the glioma and contralateral cerebral tissue. The pO2 of intracerebral 9L, C6, F98 and U251 tumors, as well as contralateral brain, were measured repeatedly for five consecutive days. The 9L glioma was well oxygenated with pO2 of 27 - 36 mm Hg, while C6, F98 and U251 glioma were hypoxic with pO2 of 7 - 12 mm Hg. The potential of multi-site EPR oximetry to assess temporal changes in tissue pO2 was investigated in rats breathing 100% O2. A significant increase in F98 tumor and contralateral brain pO2 was observed on day 1 and day 2, however, glioma oxygenation declined on subsequent days. In conclusion, EPR oximetry provides the capability to repeatedly assess temporal changes in orthotopic glioma pO2. This information could be used to test and optimize the methods being developed to modulate tumor hypoxia. Furthermore, EPR oximetry could be potentially used to enhance the outcome of chemoradiation by scheduling treatments at times of increase in glioma pO2. PMID:22079559

  8. Counterbalancing and Other Uses of Repeated-Measures Latin-Square Designs: Analyses and Interpretations.

    Science.gov (United States)

    Reese, Hayne W.

    1997-01-01

    Recommends that when repeated-measures Latin-square designs are used to counterbalance treatments across a procedural variable or to reduce the number of treatment combinations given to each participant, effects be analyzed statistically, and that in all uses, researchers consider alternative interpretations of the variance associated with the…

  9. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  10. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  11. Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

    Directory of Open Access Journals (Sweden)

    Adrian F. Ocneanu

    2017-01-01

    Full Text Available Purpose. Myocardial blood flow (MBF quantification with Rb82 positron emission tomography (PET is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic Rb82 PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1 blood-pool versus uptake region sampled input function (Blood/Uptake-ROI, (2 dual spillover correction (SOC-On/Off, (3 right blood correction (RBC-On/Off, (4 arterial blood transit delay (Delay-On/Off, and (5 distribution volume (DV constraint (Global/Regional-DV. Repeatability of MBF, stress/rest myocardial flow reserve (MFR, and stress/rest MBF difference (ΔMBF was assessed using nonparametric reproducibility coefficients (RPCnp = 1.45 × interquartile range. Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPCnp = 0.21 mL/min/g (15.8%. Corresponding MFR and ΔMBF RPCnp were 0.42 (20.2% and 0.24 mL/min/g (23.5%. MBF repeatability improved with SOC-On at stress (p<0.001 and tended to improve with RBC-Off at both rest and stress (p<0.08. DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.

  12. Brain pathology after mild traumatic brain injury: an exploratory study by repeated magnetic resonance examination.

    Science.gov (United States)

    Lannsjö, Marianne; Raininko, Raili; Bustamante, Mariana; von Seth, Charlotta; Borg, Jörgen

    2013-09-01

    To explore brain pathology after mild traumatic brain injury by repeated magnetic resonance examination. A prospective follow-up study. Nineteen patients with mild traumatic brain injury presenting with Glasgow Coma Scale (GCS) 14-15. The patients were examined on day 2 or 3 and 3-7 months after the injury. The magnetic resonance protocol comprised conventional T1- and T2-weighted sequences including fluid attenuated inversion recovery (FLAIR), two susceptibility-weighted sequences to reveal haemorrhages, and diffusion-weighted sequences. Computer-aided volume comparison was performed. Clinical outcome was assessed by the Rivermead Post-Concussion Symptoms Questionnaire (RPQ), Hospital Anxiety and Depression Scale (HADS) and Glasgow Outcome Scale Extended (GOSE). At follow-up, 7 patients (37%) reported ≥  3 symptoms in RPQ, 5 reported some anxiety and 1 reported mild depression. Fifteen patients reported upper level of good recovery and 4 patients lower level of good recovery (GOSE 8 and 7, respectively). Magnetic resonance pathology was found in 1 patient at the first examination, but 4 patients (21%) showed volume loss at the second examination, at which 3 of them reported GOSE scores of 8. Loss of brain volume, demonstrated by computer-aided magnetic resonance imaging volumetry, may be a feasible marker of brain pathology after mild traumatic brain injury.

  13. Testing Mean Differences among Groups: Multivariate and Repeated Measures Analysis with Minimal Assumptions.

    Science.gov (United States)

    Bathke, Arne C; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne

    2018-03-22

    To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer's disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved.

  14. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    1999-01-01

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  15. Visual attention to repeated print advertising : A test of scanpath theory

    NARCIS (Netherlands)

    Pieters, F.G.M.; Rosbergen, E.; Wedel, M.

    The authors examine consumers' visual attention during repeated exposures to print advertisements using eye-tracking methodology. The authors propose a statistical model comprising submodels for two key measures of visual attention to elements of the advertisement: attention duration and inter- and

  16. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  17. Examination of temporal and spatial variability of NO2 VCDs measured using mobile-MAX-DOAS in Toronto, Canada.

    Science.gov (United States)

    Davis, Zoe; Baray, Sabour; Khanbabkhani, Aida; Fujs, William; Csukat, Csilla; McLaren, Robert

    2017-04-01

    Mobile-MAX-DOAS is an innovative technique used to estimate pollutant emission rates and validate satellite measurements and air quality models. It is essential to identify and examine factors that can significantly impact the accuracy of this developing technique. Mobile-MAX-DOAS measurements were conducted in Toronto, Canada with a mini-MAX-DOAS instrument mounted (pointing backwards) on top of a car during August and September, 2016. Scattered sunlight spectra were collected every 45 seconds in the continuously repeated sequence of elevation angles of 30o, 30o, 30o, 30o, 40o, 30o, 90o. Tropospheric VCDs were determined using the geometric approximation from DSCDs fitted using a near-noon, low NO2 VCD FRS spectrum. The study goal was to examine the validity of the assumption that VCDs remain relatively constant at each measured location on a driving route encircling an urban area of interest with typical time periods of 1.5-3 hours to estimate emissions and whether driving direction significantly impacts results. NO2 VCD temporal variability was therefore determined by repeating driving routes in both directions in quick succession on multiple days. Strong temporal variability in NO2 VCDs of up to a factor of two were observed for some routes for the same vehicle locations under constant prevailing wind conditions within cities of up to 90 mg m-2hr-1. This work will be used as a baseline experiment to apply this method in other Canadian cities.

  18. The repeatability of three diagnostic methods (visual using ICDAS II, laser fluorescence, and radiographic) for early caries detection

    Science.gov (United States)

    Sukmasari, S.; Lestari, W.; Ko, B. B.; Noh, Z.; Asmail, N.; Yaacob, N.

    2017-08-01

    Newly introduced ICDAS II as a visual method, laser fluorescence as another technique that have ability to quantify early mineral loss of tooth structure and intra oral radiograph, are methods can be used in the clinic. To provide standardization for comprehensive caries management at an early stage, all methods supposed to be tested between users. The objective of this research is to evaluate the repeatability of each system. It is a comparative cross sectional study using 100 extracted permanent teeth without obvious cavitation (premolar & molar) that were collected and stored in thymol solution. The teeth were embedded on the wax block and labeled with numbers. All 5 surfaces were examined by 5 examiners using visual (ICDAS II), laser fluorescence (LF) and radiographic examination. The data were then analyzed to measure intra and inter examiner repeatability using Cronbach’s alpha and inter-item correlation matrix. Intra-examiner repeatability for all examiners was >0.7. Chronbach’s a value for inter-examiner repeatability for ICDAS II was >0.8 on 3 surfaces except on buccal and lingual. LF exhibit repeatability of >0.8 on all surfaces. Radiograph shows a low value of inter examiner repeatability (students for inter-item correlation while the 2nd and 3rd reading of LF displays the best agreement. ICDAS II score favors more non-invasive treatment compared to LF. ICDAS II showed good repeatability except on buccal and lingual surfaces. In line with some of the previous study, ICDAS II is applicable for caries detection in daily clinical basis. Laser fluorescence exhibits the highest repeatability while the radiograph showed weak inter-examiner repeatability. Treatment decisions of ICDAS II propose more preventive treatment for early caries lesions compared to laser fluorescence.

  19. Use of Repeated Blood Pressure and Cholesterol Measurements to Improve Cardiovascular Disease Risk Prediction

    DEFF Research Database (Denmark)

    Paige, Ellie; Barrett, Jessica; Pennells, Lisa

    2017-01-01

    The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data...

  20. On model selections for repeated measurement data in clinical studies.

    Science.gov (United States)

    Zou, Baiming; Jin, Bo; Koch, Gary G; Zhou, Haibo; Borst, Stephen E; Menon, Sandeep; Shuster, Jonathan J

    2015-05-10

    Repeated measurement designs have been widely used in various randomized controlled trials for evaluating long-term intervention efficacies. For some clinical trials, the primary research question is how to compare two treatments at a fixed time, using a t-test. Although simple, robust, and convenient, this type of analysis fails to utilize a large amount of collected information. Alternatively, the mixed-effects model is commonly used for repeated measurement data. It models all available data jointly and allows explicit assessment of the overall treatment effects across the entire time spectrum. In this paper, we propose an analytic strategy for longitudinal clinical trial data where the mixed-effects model is coupled with a model selection scheme. The proposed test statistics not only make full use of all available data but also utilize the information from the optimal model deemed for the data. The performance of the proposed method under various setups, including different data missing mechanisms, is evaluated via extensive Monte Carlo simulations. Our numerical results demonstrate that the proposed analytic procedure is more powerful than the t-test when the primary interest is to test for the treatment effect at the last time point. Simulations also reveal that the proposed method outperforms the usual mixed-effects model for testing the overall treatment effects across time. In addition, the proposed framework is more robust and flexible in dealing with missing data compared with several competing methods. The utility of the proposed method is demonstrated by analyzing a clinical trial on the cognitive effect of testosterone in geriatric men with low baseline testosterone levels. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Ocular surface sensitivity repeatability with Cochet-Bonnet esthesiometer.

    Science.gov (United States)

    Chao, Cecilia; Stapleton, Fiona; Badarudin, Ezailina; Golebiowski, Blanka

    2015-02-01

    To determine the repeatability of ocular surface threshold measurements using the Cochet-Bonnet esthesiometer on the same day and 3 months apart. Two separate studies were conducted to determine the repeatability of ocular surface threshold measurements made on the same day (n = 20 subjects) and 3 months apart (n = 29 subjects). The Cochet-Bonnet esthesiometer was used to measure corneal and inferior conjunctival thresholds using the ascending method of limits. The pressure exerted by the Cochet-Bonnet esthesiometer was determined using an analytical balance, for both the 0.08- and 0.12-mm-diameter filaments. This calibration was then used to convert filament length measurements to pressure. Repeatability was determined using a Bland and Altman analysis. The pressure exerted at each filament length differed between the two filament diameters. The measured pressure also differed from values provided by the manufacturer. Repeatability of threshold measurements at the central cornea was shown to be good, with better repeatability for same-day measurements (coefficient of repeatability [CoR] = ±0.23 g/mm²) than for those 3 months apart (CoR = ±0.52 g/mm²). Threshold measurements at the inferior conjunctiva, in contrast, were poorly repeatable (CoR = ±12.78 g/mm²). Cochet-Bonnet esthesiometry is repeatable when performed on the central cornea on the same day and 3 months apart, but this instrument is not recommended for conjunctival threshold measurements.

  2. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  3. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    Science.gov (United States)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-04-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  5. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  6. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... to missing data, 730 children were included in the current analytical sample. An accelerometer was worn for 7 days and 8 nights during autumn, winter and spring, from which physical activity, sedentary time and sleep duration were measured. Cardio-respiratory fitness was assessed using a 10-min intermittent...

  7. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  8. Reproducibility of regional DEXA examinations of abdominal fat and lean tissue.

    Science.gov (United States)

    Tallroth, Kaj; Kettunen, Jyrki A; Kujala, Urho M

    2013-01-01

    The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was -13 g (95% confidence interval (CI) -193.0 to 166.8), and for the repeated abdominal FM measurements it was -35 g (95% CI -178.9 to 108.5). The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes.

  9. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  10. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy.

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-07-01

    To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.

  11. A study on radiographic repeat rate data of several hospitals in Jeddah

    International Nuclear Information System (INIS)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A.

    2003-01-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m 2 . As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  12. A study on radiographic repeat rate data of several hospitals in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A

    2003-07-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m{sup 2}. As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  13. Repeated absolute gravity measurements for monitoring slow intraplate vertical deformation in Western Europe

    Science.gov (United States)

    Van Camp, M. J.; de Viron, O.; Scherneck, H.; Hinzen, K. G.; Williams, S. D.; Lecocq, T.; Quinif, Y.; Camelbeeck, T.

    2011-12-01

    In continental plate interiors, ground surface movements are at the limit of the noise level and close to or below the accuracy of current geodetic techniques. Absolute gravity measurements are valuable to quantify slow vertical movements, as this instrument is drift free and, unlike GPS, independent of the terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformation in the area. The AG measurements, repeated once or twice a year, can resolve elusive gravity changes with a precision better than 3.7 nm/s2/yr (95% confidence interval) after 11 years, even in difficult conditions. After 8-15 years (depending on the station), we find that the gravity rates of change lie in the [-3.1, 8.1] nm/s2/yr interval and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. After correcting for the GIA, the inferred gravity rates and consequently, the vertical land movements, reduce to zero within the uncertainty level at all stations except Jülich (due to man-induced subsidence) and Sohier (possibly, an artefact due to the shortness of the time series at that station).

  14. Education for patients with chronic kidney disease in Taiwan: a prospective repeated measures study.

    Science.gov (United States)

    Yen, Miaofen; Huang, Jeng-Jong; Teng, Hsiu-Lan

    2008-11-01

    To investigate the physical, knowledge and quality of life outcomes of an educational intervention for patients with early stage chronic kidney disease. A comprehensive predialysis education care team can be effective in slowing the progression of chronic kidney disease. A single group repeated measures design was used to evaluate the effects of the intervention. Participants were recruited through health department community health screen data banks. A predialysis, team-delivered educational intervention covering renal function health care, dietary management of renal function and the effects of Chinese herb medication on renal function was designed and implemented. Data were collected at baseline, six and 12 months. Study outcomes included physical indicators, knowledge (renal function protection, use of Chinese herbs and renal function and diet) and quality of life. Data were analysed using repeated measure anova to test for change over time in outcome variables. Sixty-six persons participated in this study. The predialysis educational intervention showed significant differences at the three time points in overall knowledge scores, waist-hip ratio, body mass index and global health status. Knowledge measures increased at month 6 and decreased at month 12. The primary indicator of renal function, glomerular filtration rate, remained stable throughout the 12 months of follow-up, despite the relatively older mean age of study participants. A predialysis education care team can provide effective disease-specific knowledge and may help retard deterioration of renal function in persons with early-stage chronic kidney disease. The intervention dose may need to be repeated every six months to maintain knowledge effects. A predialysis educational program with disease-specific knowledge and information is feasible and may provide positive outcomes for patients. Topics on the uses of Chinese herbs should be included for people who are likely to use alternative therapies.

  15. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-01-01

    Purpose To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. Methods Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). Results For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Conclusions Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions. PMID:28738413

  16. Repeated DNA sequences in fungi

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, S K

    1974-11-01

    Several fungal species, representatives of all broad groups like basidiomycetes, ascomycetes and phycomycetes, were examined for the nature of repeated DNA sequences by DNA:DNA reassociation studies using hydroxyapatite chromatography. All of the fungal species tested contained 10 to 20 percent repeated DNA sequences. There are approximately 100 to 110 copies of repeated DNA sequences of approximately 4 x 10/sup 7/ daltons piece size of each. Repeated DNA sequence homoduplexes showed on average 5/sup 0/C difference of T/sub e/50 (temperature at which 50 percent duplexes dissociate) values from the corresponding homoduplexes of unfractionated whole DNA. It is suggested that a part of repetitive sequences in fungi constitutes mitochondrial DNA and a part of it constitutes nuclear DNA. (auth)

  17. Evidence of radiation-induced reduction of height and body weight from repeated measurements of adults exposed in childhood to the atomic bombs

    International Nuclear Information System (INIS)

    Otake, Masanori; Funamoto, Sachiyo; Fujikoshi, Yasunori; Schull, W.J.

    1994-01-01

    Reduction of growth from exposure to atomic bomb radiation has been examined using individuals under 10 years old at the time of the bombing (ATB) and a growth curve analysis based on measurements of height and weight made in the course of the 4th-7th cycles of the Adult Health Study examinations (1964-1972). As expected, the largest difference in growth to emerge is between males and females. However, a highly significant reduction of growth associated with dose (DS86) was observed among those survivors for whom four repeated measurements of height and weight were available. Longitudinal analysis of a more extended data set (n = 821), using expected values based on simple linear regression models fitted to the three available sets of measurements of height and weight on the 254 individuals with a missing measurement, also indicates a significant radiation-related growth reduction. The possible contribution of such factors as poor nutrition and disruption of normal family life in the years immediately after the war is difficult to evaluate, but the effects of socioeconomic factors on the analysis of these data are discussed. 33 refs., 5 figs., 3 tabs

  18. Intelligence is in the eye of the beholder: investigating repeated IQ measurements in forensic psychiatry.

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-05-01

    A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were computed, and each IQ score was categorized. Additionally, t-tests and regression analyses were performed. Differences of 10 points or more were found in 66% of the cases comparing WAIS-III with RAVEN scores. Fisher's exact test revealed differences between two WAIS-III scores and the WAIS categories. The WAIS-III did not predict other IQs (WAIS or RAVEN) in participants with intellectual disability. This study showed that stability or interchangeability of scores is lacking, especially in individuals with intellectual disability. Caution in interpreting IQ scores is therefore recommended, and the use of the unitary concept of IQ should be discouraged. © 2014 John Wiley & Sons Ltd.

  19. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  20. Recommendations for analysis of repeated-measures designs: testing and correcting for sphericity and use of manova and mixed model analysis.

    Science.gov (United States)

    Armstrong, Richard A

    2017-09-01

    A common experimental design in ophthalmic research is the repeated-measures design in which at least one variable is a within-subject factor. This design is vulnerable to lack of 'sphericity' which assumes that the variances of the differences among all possible pairs of within-subject means are equal. Traditionally, this design has been analysed using a repeated-measures analysis of variance (RM-anova) but increasingly more complex methods such as multivariate anova (manova) and mixed model analysis (MMA) are being used. This article surveys current practice in the analysis of designs incorporating different factors in research articles published in three optometric journals, namely Ophthalmic and Physiological Optics (OPO), Optometry and Vision Science (OVS), and Clinical and Experimental Optometry (CXO), and provides advice to authors regarding the analysis of repeated-measures designs. Of the total sample of articles, 66% used a repeated-measures design. Of those articles using a repeated-measures design, 59% and 8% analysed the data using RM-anova or manova respectively and 33% used MMA. The use of MMA relative to RM-anova has increased significantly since 2009/10. A further search using terms to select those papers testing and correcting for sphericity ('Mauchly's test', 'Greenhouse-Geisser', 'Huynh and Feld') identified 66 articles, 62% of which were published from 2012 to the present. If the design is balanced without missing data then manova should be used rather than RM-anova as it gives better protection against lack of sphericity. If the design is unbalanced or with missing data then MMA is the method of choice. However, MMA is a more complex analysis and can be difficult to set up and run, and care should be taken first, to define appropriate models to be tested and second, to ensure that sample sizes are adequate. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  1. Characterisation and measurement of signals generated by DVB-H 'gap-filler' repeaters

    International Nuclear Information System (INIS)

    Baldini, M.; Barellini, A.; Bogi, L.; Licitra, G.; Silvi, A. M.; Zari, A.

    2009-01-01

    DVB-H (Digital Video Broadcasting Hand-held) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains. (authors)

  2. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  3. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  4. Repeated measurements of NT-pro-B-type natriuretic peptide, troponin T or C-reactive protein do not predict future allograft rejection in heart transplant recipients.

    Science.gov (United States)

    Battes, Linda C; Caliskan, Kadir; Rizopoulos, Dimitris; Constantinescu, Alina A; Robertus, Jan L; Akkerhuis, Martijn; Manintveld, Olivier C; Boersma, Eric; Kardys, Isabella

    2015-03-01

    Studies on the prognostic value of serial biomarker assays for future occurrence of allograft rejection (AR) are scarce. We examined whether repeated measurements of NT-pro-B-type natriuretic peptide (NT-proBNP), troponin T (TropT) and C-reactive protein (CRP) predict AR. From 2005 to 2010, 77 consecutive heart transplantation (HTx) recipients were included. The NT-proBNP, TropT, and CRP were measured at 16 ± 4 (mean ± standard deviation) consecutive routine endomyocardial biopsy surveillance visits during the first year of follow-up. Allograft rejection was defined as International Society for Heart and Lung Transplantation (ISHLT) grade 2R or higher at endomyocardial biopsy. Joint modeling was used to assess the association between repeated biomarker measurements and occurrence of future AR. Joint modeling accounts for dependence among repeated observations in individual patients. The mean age of the patients at HTx was 49 ± 9.2 years, and 68% were men. During the first year of follow-up, 1,136 biopsies and concurrent blood samples were obtained, and 56 patients (73%) experienced at least one episode of AR. All biomarkers were elevated directly after HTx and achieved steady-state after ∼ 12 weeks, both in patients with or without AR. No associations were present between the repeated measurements of NT-proBNP, TropT, or CRP and AR both early (weeks 0-12) and late (weeks 13-52) in the course after HTx (hazard ratios for weeks 13-52: 0.96 (95% confidence interval, 0.55-1.68), 0.67 (0.27-1.69), and 1.44 (0.90-2.30), respectively, per ln[unit]). Combining the three biomarkers in one model also rendered null results. The temporal evolution of NT-proBNP, TropT, and CRP before AR did not predict occurrence of acute AR both in the early and late course of the first year after HTx.

  5. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    with first year seed crops using three sowing rates and three spring nitrogen (N) application rates. PLSR models were developed for each year and showed correlation coefficients of 0.71, 0.76, and 0.92, respectively. Regression coefficients showed in these experiments that the optimum time for canopy...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development......Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...

  6. Performance Analysis of Measurement Inaccuracies of IMU/GPS on Airborne Repeat-pass Interferometric SAR in the Presence of Squint

    Directory of Open Access Journals (Sweden)

    Deng Yuan

    2014-08-01

    Full Text Available In the MOtion COmpensation (MOCO approach to airborne repeat-pass interferometric Synthetic Aperture Radar (SAR based on motion measurement data, the measurement inaccuracies of Inertial Measurement Unit/Global Positioning System (IMU/GPS and the positioning errors of the target, which may contribute to the residual uncompensated motion errors, affect the imaging result and interferometric measurement. Considering the effects of the two types of error, this paper builds a mathematical model of residual motion errors in presence of squint, and analyzes the effects on the residual motion errors induced by the measurement inaccuracies of IMU/GPS and the positioning errors of the target. In particular, the effects of various measurement inaccuracies of IMU/GPS on interferometric SAR image quality, interferometric phase, and digital elevation model precision are disscussed. Moreover, the paper quantitatively researches the effects of residual motion errors on airborne repeat-pass interferometric SAR through theoretical and simulated analyses and provides theoretical bases for system design and signal processing.

  7. Short-term Changes of Apparent Optical Properties in a Shallow Water Environment: Observations from Repeated Airborne Hyperspectral Measurements

    Science.gov (United States)

    Zhang, M.; English, D. C.; Hu, C.; Carlson, P. R., Jr.; Muller-Karger, F. E.; Toro-Farmer, G.; Herwitz, S. R.

    2016-02-01

    An atmospheric correction algorithm has been developed for AISA imagery over optically shallow waters in Sugarloaf Key of the Florida Keys. The AISA data were collected repeatedly during several days in May 2012, October 2012, and May 2013. A non-zero near-infrared (NIR) remote sensing reflectance (Rrs) was accounted for through iterations, based on the relationship of field-measured Rrs between the NIR and red wavelengths. Validation showed mean ratios of 0.94 to 1.002 between AISA-derived and field-measured Rrs in the blue to red wavelengths, with uncertainties generally turbidity (light attenuation) and bottom contributions. Some of these changes are larger than two times of the Rrs uncertainties from the AISA retrievals, therefore representing statistically significant changes that can be well observed from airborne measurements. The case study suggests that repeated airborne measurements may be used to study short-term changes in shallow water environments, and such a capacity may be enhanced with future geostationary satellite missions specifically designed to observe coastal ecosystems.

  8. The effects of toluene plus noise on hearing thresholds: an evaluation based on repeated measurements in the German printing industry.

    Science.gov (United States)

    Schäper, Michael; Seeber, Andreas; van Thriel, Christoph

    2008-01-01

    The ototoxicity of occupational exposure to toluene plus noise was investigated in a longitudinal study in rotogravure printing and existing findings in the literature were evaluated. The study comprised four repeated examinations during 5 years and started with 333 male workers. Lifetime weighted average exposures (LWAE) to toluene and noise were determined from individual work histories and historic recordings; recent individual exposures were measured 10 times during the study (toluene, active sampling; noise, stationary measurements). Auditory thresholds were measured with pure tone audiometry at 0.125, 0.25, 0.5, 0.75, 1, 2, 3, 4, 6, 8, 12 kHz. Mean LWAE exposures to toluene and noise were 45+/-17 ppm plus 82+/-7 dB(A) for high toluene exposed and 10+/-7 ppm plus 82+/-4 dB(A) for low toluene exposed subjects, mean current exposures were 26+/-20 ppm plus 81+/-4 dB(A) and 3+/-3 ppm plus 82+/-4 dB(A). Mean exposure duration was 21.3+/-6.5 years for long exposed and 5.9+/-2.2 years for short exposed subjects. Repeated measurement analyses of variance did not reveal effects of toluene intensity, exposure duration and interactions between toluene intensity and noise intensity. Noise intensity [79+/-3 dB(A) vs. 84+/-1 dB(A)] was significant for auditory thresholds. A case concept utilising developments of individual auditory thresholds did not reveal significant toluene effects. Logistic models including age, exposure duration, toluene in ambient air, current noise and either hippuric acid or ortho-cresol (o-cresol) found only age to be significant for elevated OR of high frequency hearing loss. Due to missing toluene effects, it was concluded that the threshold level for developing hearing loss as a result of occupational exposure to toluene plus noise might be above the current limit of 50 ppm toluene.

  9. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  10. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  11. Theoretical repeatability assessment without repetitive measurements in gradient high-performance liquid chromatography.

    Science.gov (United States)

    Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki

    2016-07-08

    This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Parsimonious Structural Equation Models for Repeated Measures Data, with Application to the Study of Consumer Preferences

    Science.gov (United States)

    Elrod, Terry; Haubl, Gerald; Tipps, Steven W.

    2012-01-01

    Recent research reflects a growing awareness of the value of using structural equation models to analyze repeated measures data. However, such data, particularly in the presence of covariates, often lead to models that either fit the data poorly, are exceedingly general and hard to interpret, or are specified in a manner that is highly data…

  13. The relationship of social support concept and repeat mammography among Iranian women.

    Science.gov (United States)

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  14. Complement consumption by double culture of Paramecium caudatum and Aerobacter cloacae in repeated examination in relation to the individual radiosensitivity

    International Nuclear Information System (INIS)

    Bernasovsky, I.; Cabadaj, S.; Praslicka, M.; Chlebovska, K.

    1976-01-01

    Two sets of rats were repeatedly examined by the complement consumption test with a double culture of Paramecium caudatum and Aerobacter cloacae (DPA). The first set was examined 11 days and 1 day before irradiation with 0.15 C/kg, the second 6 days before and 4 days after irradiation with 0.15 C/kg. The intensity of reaction and thus the relative titres of the examined antibodies were expressed numerically by the NMHD symbol, i.e., by the number of minimal hemolytical complement doses consumed in the reaction. This reaction is known as the NMHD test. The proportion of rats with a high NMHD which survived 30 days after irradiation was higher than that of rats with low reaction values. Rats having in one examination a high NMHD value and in the second a low one (the sequence high-low or low-high is not important) were more radioresistant than those with permanently low reaction values and did not basically differ from the animals with permanently high NMHD values. Bacteriae Aerobacter cloacae represent the antigenically effective substance of DNA. (author)

  15. Complement consumption by double culture of Paramecium caudatum and Aerobacter cloacae in repeated examination in relation to the individual radiosensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Bernasovsky, I; Cabadaj, S; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1976-01-01

    Two sets of rats were repeatedly examined by the complement consumption test with a double culture of Paramecium caudatum and Aerobacter cloacae (DPA). The first set was examined 11 days and 1 day before irradiation with 0.15 C/kg, the second 6 days before and 4 days after irradiation with 0.15 C/kg. The intensity of reaction and thus the relative titres of the examined antibodies were expressed numerically by the NMHD symbol, i.e., by the number of minimal hemolytical complement doses consumed in the reaction. This reaction is known as the NMHD test. The proportion of rats with a high NMHD which survived 30 days after irradiation was higher than that of rats with low reaction values. Rats having in one examination a high NMHD value and in the second a low one (the sequence high-low or low-high is not important) were more radioresistant than those with permanently low reaction values and did not basically differ from the animals with permanently high NMHD values. Bacteriae Aerobacter cloacae represent the antigenically effective substance of DNA.

  16. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  17. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  18. Examiner Reliability of Fluorosis Scoring: A Comparison of Photographic and Clinical Examination Findings

    Science.gov (United States)

    Cruz-Orcutt, Noemi; Warren, John J.; Broffitt, Barbara; Levy, Steven M.; Weber-Gasparoni, Karin

    2012-01-01

    Objective To assess and compare examiner reliability of clinical and photographic fluorosis examinations using the Fluorosis Risk Index (FRI) among children in the Iowa Fluoride Study (IFS). Methods The IFS examined 538 children for fluorosis and dental caries at age 13 and obtained intra-oral photographs from nearly all of them. To assess examiner reliability, duplicate clinical examinations were conducted for 40 of the subjects. In addition, 200 of the photographs were scored independently for fluorosis by two examiners in a standardized manner. Fluorosis data were compared between examiners for the clinical exams and separately for the photographic exams, and a comparison was made between clinical and photographic exams. For all 3 comparisons, examiner reliability was assessed using kappa statistics at the tooth level. Results Inter-examiner reliability for the duplicate clinical exams on the sample of 40 subjects as measured by kappa was 0.59, while the repeat exams of the 200 photographs yielded a kappa of 0.64. For the comparison of photographic and clinical exams, inter-examiner reliability, as measured by weighted kappa, was 0.46. FRI scores obtained using the photographs were higher on average than those obtained from the clinical exams. Fluorosis prevalence was higher for photographs (33%) than found for clinical exam (18%). Conclusion Results suggest inter-examiner reliability is greater and fluorosis scores higher when using photographic compared to clinical examinations. PMID:22316120

  19. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    Science.gov (United States)

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Tectonic, Climatic and Anthropogenic Vertical Land Movements in Western Europe by Repeated Absolute Gravity Measurements

    Science.gov (United States)

    van Camp, M. J.; de Viron, O.; Lecocq, T.; Hinzen, K. G.; Quinif, Y.; Williams, S. D.; Camelbeeck, T.

    2010-12-01

    In continental plate interiors, tectonic deformations are small and the associated ground surface movements remain close to or below the accuracy of current geodetic techniques, and at the limit of the noise level. An absolute gravimeter is an appropriate tool to quantify slow vertical movements, as this instrument, based on length and time standards, is drift free and does not depend on any terrestrial reference frame. Repeated absolute gravity (AG) measurements have been performed in Oostende (Belgian coastline) and at 8 stations along a southwest-northeast profile across the Belgian Ardennes and the Roer Valley Graben (Germany), in order to estimate the tectonic deformations in the area. After 7-13 years (depending on the station), we find evidence that the movements are no larger than a few millimeter per year and result from a combination of anthropogenic, climatic, tectonic, and Glacial Isostatic Adjustment (GIA) effects. This demonstrates the importance of precisely modeling the GIA effects in order to investigate intraplate tectonic deformations at the sub-millimeter level. This study also shows that AG measurements, repeated once or twice a year, can resolve vertical velocities at the 1.0 mm/yr level after 10 years, even in difficult conditions, provided that the gravimeter is carefully maintained.

  1. Psychosocial outcomes of Hong Kong Chinese diagnosed with acute coronary syndromes: a prospective repeated measures study.

    Science.gov (United States)

    Chan, Dominic S K; Chau, Janita P C; Chang, Anne M

    2007-08-01

    Western studies have suggested that emotional stress and distress impacted on the morbidity and mortality in people following acute coronary events. Symptoms of anxiety and depression have been associated with re-infarction and death, prolonged recovery and disability and depression may precipitate the client's low self-esteem. This study examined perceived anxiety, depression and self-esteem of Hong Kong Chinese clients diagnosed with acute coronary syndrome (ACS) over a 6-month period following hospital admission. To examine: A prospective, repeated measures design with measures taken on two occasions over a 6-month period; (1) within the 1st week of hospital admission following the onset of ACS and (2) at 6 months follow up. Convenient sample of 182 voluntary consented clients admitted with ACS to a major public hospital in Hong Kong who could communicate in Chinese, complete questionnaires, cognitive intact, and were haemodynamically stable and free from acute chest pain at the time of interview. Baseline data were obtained within 1 week after hospital admission. The follow-up data was collected 6 months after hospital discharge. The Chinese version of the Hospital Anxiety and Depression Scale (HADS), State Self-esteem Scale (SSES), and Rosenberg's Self-Esteem Scale (RSES) were used to assess anxiety and depression, state self-esteem, and trait self-esteem, respectively. Findings suggested gender differences in clients' perception in anxiety, depression and self-esteem. Improvements in clients' perception of these variables were evident over the 6-month period following their acute coronary events. The study confirmed the western notion that psychosocial problems are common among coronary clients and this also applies to Hong Kong Chinese diagnosed with ACS. Further studies to explore effective interventions to address these psychosocial issues are recommended.

  2. The Effects of Repeated Experience on Children's Suggestibility.

    Science.gov (United States)

    Powell, Martine B.; Roberts, Kim P.; Ceci, Stephen J.; Hembrooke, Helene

    1999-01-01

    Examined effect of suggestive questions on 3- to 5-year-olds' and 6- to 8-year-olds' recall of the final occurrence of repeated event. Found that relative to reports of children experiencing single occurrence, reports about fixed items of repeated events were less contaminated by false suggestions. Children's age and delay of interview were…

  3. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  4. Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds.

    Science.gov (United States)

    Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip

    2018-03-22

    To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.

  5. Repeated Causal Decision Making

    Science.gov (United States)

    Hagmayer, York; Meder, Bjorn

    2013-01-01

    Many of our decisions refer to actions that have a causal impact on the external environment. Such actions may not only allow for the mere learning of expected values or utilities but also for acquiring knowledge about the causal structure of our world. We used a repeated decision-making paradigm to examine what kind of knowledge people acquire in…

  6. Violation of the Sphericity Assumption and Its Effect on Type-I Error Rates in Repeated Measures ANOVA and Multi-Level Linear Models (MLM).

    Science.gov (United States)

    Haverkamp, Nicolas; Beauducel, André

    2017-01-01

    We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The

  7. Reject/repeat analysis and the effect prior film viewing has on a department's reject/repeat rate

    International Nuclear Information System (INIS)

    Clark, P.A.; Hogg, P.

    2003-01-01

    Purpose: Achieving cost-effectiveness within the NHS is an old initiative but one that has again been highlighted by recent government policies (The New NHS-Modern and Dependable, Stationary Office, London, 1997). It has been reiterated that it is the responsibility of individual Trusts to devise means to provide such a service. Reject/repeat analyses have long been the primary tool used to assess the cost-effectiveness of radiography departments (Quality Assurance in Diagnostic Radiology, WHO, Geneva, 1982). This research paper examines an in-house initiative (viewing patients' previous films) commonly employed in other Health Trusts in order to reduce departmental repeat/reject rates. Method: Three hundred orthopaedic patients with hip, knee and ankle prostheses were included in a reject/repeat analysis. The aim was to investigate whether or not viewing patient's previous relevant radiographs would be advantageous to the practicing radiographer. This was done through an audit cycle consisting of two audit periods each lasting for 3 months. The primary audit period recorded the baseline repeat/reject rate, with the secondary audit period recording the repeat/reject rate under an experimental condition of viewing the relevant radiographs. Results: The baseline audit revealed repeat rates of 33% in orthopaedic patients with hip, knee and ankle prostheses. The availability of prior film viewing to the radiographer reduced this repeat rate to 10.6%. Conclusion: Prior film viewing dramatically reduced the department's repeat/reject rate by 22.4%. This provides scope for significant patient dose reductions as well as reducing departmental film expenses. This is an underestimated initiative and should be used appropriately in routine clinical practice

  8. CO2 measurements during transcranial Doppler examinations in headache patients

    DEFF Research Database (Denmark)

    Thomsen, L L; Iversen, Helle Klingenberg

    1994-01-01

    Transcranial Doppler (TCD) examinations are increasingly being used in studies of headache pathophysiology. Because blood velocity is highly dependent on PCO2, these parameters should be measured simultaneously. The most common way of performing measurements during TCD examinations is as end......-tidal pCO2 with a capnograph. When patients are nauseated and vomit, as in migraine, the mask or mouthpiece connected to the capnograph represents a problem. We therefore evaluated whether a transcutaneous pCO2 electrode was as useful as the capnograph for pCO2 measurements in TCD examinations. We...... conclude that this is not the case, and recommend capnographic end-tidal pCO2 measurements during TCD examinations. However, transcutaneous pCO2 measurements may represent a supplement to spot measurements of end-tidal pCO2 in stable conditions when long-term monitoring is needed, and the mask...

  9. PERFORMANCE MEASURES OF STUDENTS IN EXAMINATIONS: A STOCHASTIC APPROACH

    OpenAIRE

    Goutam Saha; GOUTAM SAHA

    2013-01-01

    Data on Secondary and Higher Secondary examination (science stream) results from Tripura (North-East India) schools are analyzed to measure the performance of students based on tests and also the performance measures of schools based on final results and continuous assessment processes are obtained. The result variation in terms of grade points in the Secondary and Higher Secondary examinations are analysed using different sets of performance measures. The transition probabilities from one g...

  10. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  11. Acute caffeine effect on repeatedly measured P300

    OpenAIRE

    Pan, Jingbo; Takeshita, Tatsuya; Morimoto, Kanehisa

    2000-01-01

    The acute effect of a single-dose of caffeine on the P300 event-related brain potential (ERP) was assessed in a study using a repeatedly presented auditory oddball button-press task. A dose (5mg/kg body-weight) of either caffeine or placebo lactose, dissolved in a cup of decaffeinated coffee, was administered double-blindly to coffee drinkers who had abstained from coffee for 24hrs, with the presentation order of the sessions counterbalanced and separated by 2–4 weeks. The caffeine-treatment ...

  12. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  13. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    Science.gov (United States)

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  14. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  15. Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

    Science.gov (United States)

    Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C

    2015-07-01

    The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p rc = 0.9981 vs. 0.9953; p plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.

  16. Myotonin protein-kinase [AGC]n trinucleotide repeat in seven nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, G.; Sineo, L.; Pontieri, E. [Catholic Univ. of Rome (Italy)]|[Univ. of Milan (Italy)]|[Univ. Florence (Italy)] [and others

    1994-09-01

    Myotonic dystrophy (DM) is due to a genomic instability of a trinucleotide [AGC]n motif, located at the 3{prime} UTR region of a protein-kinase gene (myotonin protein kinase, MT-PK). The [AGC] repeat is meiotically and mitotically unstable, and it is directly related to the manifestations of the disorder. Although a gene dosage effect of the MT-PK has been demonstrated n DM muscle, the mechanism(s) by which the intragenic repeat expansion leads to disease is largely unknown. This non-standard mutational event could reflect an evolutionary mechanism widespread among animal genomes. We have isolated and sequenced the complete 3{prime}UTR region of the MT-PK gene in seven primates (macaque, orangutan, gorilla, chimpanzee, gibbon, owl monkey, saimiri), and examined by comparative sequence nucleotide analysis the [AGC]n intragenic repeat and the surrounding nucleotides. The genomic organization, including the [AGC]n repeat structure, was conserved in all examined species, excluding the gibbon (Hylobates agilis), in which the [AGC]n upstream sequence (GGAA) is replaced by a GA dinucleotide. The number of [AGC]n in the examined species ranged between 7 (gorilla) and 13 repeats (owl monkeys), with a polymorphism informative content (PIC) similar to that observed in humans. These results indicate that the 3{prime}UTR [AGC] repeat within the MT-PK gene is evolutionarily conserved, supporting that this region has important regulatory functions.

  17. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  18. To be so bold: boldness is repeatable and related to within individual behavioural variability in North Island robins.

    Science.gov (United States)

    He, Ruchuan; Pagani-Núñez, Emilio; Chevallier, Clément; Barnett, Craig R A

    2017-07-01

    Behavioural research traditionally focusses on the mean responses of a group of individuals rather than variation in behaviour around the mean or among individuals. However, examining the variation in behaviour among and within individuals may also yield important insights into the evolution and maintenance of behaviour. Repeatability is the most commonly used measure of variability among individuals in behavioural research. However, there are other forms of variation within populations that have received less attention. One such measure is intraindividual variation in behaviour (IIV), which is a short-term fluctuation of within-individual behaviour. Such variation in behaviour might be important during interactions because it could decrease the ability of conspecific and heterospecific individuals to predict the behaviour of the subject, thus increasing the cost of the interaction. In this experiment, we made repeated measures of the latency of North Island robins to attack a prey in a novel situation (a form of boldness) and examined (i) repeatability of boldness (the propensity to take a risk), (ii) IIV of boldness, and (iii) whether there was a significant relationship between these two traits (a behavioural syndrome). We found that boldness was highly repeatable, that there were high levels of IIV in boldness, and that there was a negative relationship between boldness and IIV in boldness. This suggests that despite high levels of repeatability for this behaviour, there were also still significant differences in IIV among different individuals within the population. Moreover, bolder individuals had significantly less IIV in their boldness, which suggests that they were forming routines (which reduces behavioural variability) compared to shyer individuals. Our results definitively demonstrate that IIV itself varies across individuals and is linked with key behavioural traits, and we argue for the importance of future studies aimed at understanding its causes

  19. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography.

    Directory of Open Access Journals (Sweden)

    Hannah V Wilson

    Full Text Available The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG has not been published.To investigate the; (1 reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm, (2 effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude and contraction time (Tc, (3 the effect of changing inter-electrode distance on Dm and Tc.Within subject, repeated measures.10 participants for each objective.Dm and Tc of the rectus femoris, measured using TMG.The coefficient of variance (CV and the intra-class correlation (ICC of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively.Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles.

  20. Perfectionism and negative affect after repeated failure: Anxiety, depression, and anger

    OpenAIRE

    Stoeber, Joachim; Schneider, Natalia; Hussain, Rimi; Matthews, Kelly

    2014-01-01

    Perfectionists have shown increased negative affect after failure compared to nonperfectionists. However, little is known about how perfectionists react to repeated failure. This study investigated the effects of two forms of perfectionism--self-oriented perfectionism and socially prescribed perfectionism--on 100 university students’ reactions to repeated failure (versus repeated success) examining three negative emotions: anxiety, depression, and anger. Results showed that socially prescribe...

  1. Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST

    Directory of Open Access Journals (Sweden)

    Bernardo T. Lopes

    2017-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of dynamic corneal response parameters measured by the Corvis ST (Oculus, Wetzlar, Germany. Methods. One eye randomly selected from 32 healthy volunteers was examined by the Corvis ST. Three different devices were used in an alternated random order for taking three measurements at each device in each subject. Standard intraocular pressure (IOP, the biomechanical-compensated IOP (bIOP, and DCR parameters were evaluated. The within-subject standard deviation (ζw and coefficient of variation (CV were assessed. Results. Regarding pressure indices, the ζw was below 1 mmHg for repeatability (0.98 for IOP and 0.89 for bIOP and the CV was 6.6% for IOP and 6.1% for bIOP. For reproducibility, the ζw was around 1 mmHg (1.12 for IOP and 1.05 for bIOP and the CV was 7.6% for IOP and 7.1% for bIOP. Most of DCR indices presented CV for repeatability below 4%. For reproducibility, the CV of most of the indices were below 6%. The deformation amplitude (DA ratio in 1 mm and integrated radius were below 4% (1.2% and 3.8%, resp.. Conclusions. The Corvis ST showed good precision (repeatability and reproducibility for IOP measurements and for DCR in healthy eyes.

  2. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor) variables? This question was answered using generalized...... involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...

  3. The effect of mere measurement from a cardiovascular examination program on physical activity and sedentary time in an adult population.

    Science.gov (United States)

    Voigt, Lisa; Baumann, Sophie; Ullrich, Antje; Weymar, Franziska; John, Ulrich; Ulbricht, Sabina

    2018-01-01

    Measuring physical activity (PA) and sedentary time (ST) by self-report or device as well as assessing related health factors may alter those behaviors. Thus, in intervention trials assessments may bias intervention effects. The aim of our study was to examine whether leisure-time PA, transport-related PA, and overall ST measured via self-report vary after assessments and whether a brief tailored letter intervention has an additional effect. Among a sample of subjects with no history of myocardial infarction, stroke, or vascular intervention, a number of 175 individuals participated in a study comprising multiple repeated assessments. Of those, 153 were analyzed (mean age 54.5 years, standard deviation = 6.2; 64% women). At baseline, participants attended a cardiovascular examination (standardized measurement of blood pressure and waist circumference, blood sample taking) and wore an accelerometer for seven days. At baseline and after 1, 6, and 12 months, participants completed the International Physical Activity Questionnaire. A random subsample received a tailored counseling letter intervention at month 1, 3, and 4. Changes in PA and ST from baseline to 12-month follow-up were analyzed using random-effects modelling. From baseline to 1-month assessment, leisure-time PA did not change (Incidence rate ratio = 1.13, p  = .432), transport-related PA increased (Incidence rate ratio = 1.45, p  = .023), and overall ST tended to decrease (b = - 1.96, p  = .060). Further, overall ST decreased from month 6 to month 12 (b = - 0.52, p  = .037). Time trends of the intervention group did not differ significantly from those of the assessment-only group. Results suggest an effect of measurements on PA and ST. Data of random-effects modelling results revealed an increase of transport-related PA after baseline to 1-month assessment. Decreases in overall ST may result from repeated assessments. A brief tailored letter intervention seemed to

  4. The effectiveness of eye-closure in repeated interviews

    NARCIS (Netherlands)

    Vredeveldt, A.; Baddeley, A.D.; Hitch, G.J.

    2014-01-01

    Purpose Closing the eyes during recall can help witnesses remember more about a witnessed event. This study examined the effectiveness of eye-closure in a repeated recall paradigm with immediate free recall followed 1 week later by both free and cued recall. We examined whether eye-closure was more

  5. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  6. Direct and Repeated Clinical Measurements of pO2 for Enhancing Cancer Therapy and Other Applications.

    Science.gov (United States)

    Swartz, Harold M; Williams, Benjamin B; Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A; Chen, Eunice Y; Schaner, Philip E; Ali, Arif; Gallez, Bernard; Kuppusamy, Periannan; Flood, Ann B

    2016-01-01

    The first systematic multi-center study of the clinical use of EPR oximetry has begun, with funding as a PPG from the NCI. Using particulate oxygen sensitive EPR, materials in three complementary forms (India Ink, "OxyChips", and implantable resonators) the clinical value of the technique will be evaluated. The aims include using repeated measurement of tumor pO2 to monitor the effects of treatments on tumor pO2, to use the measurements to select suitable subjects for the type of treatment including the use of hyperoxic techniques, and to provide data that will enable existing clinical techniques which provide data relevant to tumor pO2 but which cannot directly measure it to be enhanced by determining circumstances where they can give dependable information about tumor pO2.

  7. The importance of position and path repeatability on force at the knee during six-DOF joint motion.

    Science.gov (United States)

    Darcy, Shon P; Gil, Jorge E; Woo, Savio L-Y; Debski, Richard E

    2009-06-01

    Mechanical devices, such as robotic manipulators have been designed to measure joint and ligament function because of their ability to position a diarthrodial joint in six degrees-of-freedom with fidelity. However, the precision and performance of these testing devices vary. Therefore, the objective of this study was to determine the effect of systematic errors in position and path repeatability of two high-payload robotic manipulators (Manipulators 1 and 2) on the resultant forces at the knee. Using a porcine knee, the position and path repeatability of these manipulators were determined during passive flexion-extension with a coordinate measuring machine. The position repeatability of Manipulator 1 was 0.3 mm in position and 0.2 degrees in orientation while Manipulator 2 had a better position repeatability of 0.1 mm in position and 0.1 degrees in orientation throughout the range of positions examined. The corresponding variability in the resultant force at the knee for these assigned positions was 32+/-33 N for Manipulator 1 and 4+/-1 N for Manipulator 2. Furthermore, the repeatability of the trajectory of each manipulator while moving between assigned positions (path repeatability) was 0.8 mm for Manipulator 1 while the path repeatability for Manipulator 2 was improved (0.1 mm). These path discrepancies produced variability in the resultant force at the knee of 44+/-24 and 21+/-8 N, respectively, for Manipulators 1 and 2 primarily due to contact between the articular surfaces of the tibia and femur. Therefore, improved position and path repeatability yields lower variability in the resultant forces at the knee. Although position repeatability has been the most common criteria for evaluating biomechanical testing devices, the current study has clearly demonstrated that path repeatability can have an even larger effect on the variability in resultant force at the knee. Consequently, the repeatability of the path followed by the joint throughout its prescribed

  8. A maximal cycle test with good validity and high repeatability in adults of all ages

    DEFF Research Database (Denmark)

    Eriksen, L; Tolstrup, J S; Larsen, Steen

    2014-01-01

    indirectly in both tests and measured directly in one test. Agreement between the direct measurement and the indirect estimate of VO2max and repeatability of the indirect estimates of VO2max were examined by Bland-Altman plots, limits of agreement (LOA) and coefficient of repeatability (CR). The indirect...... method (mean VO2max=3 132 ml · min(-1)) underestimated VO2max as compared to the direct method (mean VO2max=3 190 ml · min(-1)) in men (bias: 58 ml · min(-1) (95% LOA-450 and 565)) and overestimated VO2max in women (mean VO2max=2 328 vs. 2 258 ml · min(-1), bias: - 70 ml · min(-1) (95% LOA-468 and 328...

  9. A Modified Jonckheere Test Statistic for Ordered Alternatives in Repeated Measures Design

    Directory of Open Access Journals (Sweden)

    Hatice Tül Kübra AKDUR

    2016-09-01

    Full Text Available In this article, a new test based on Jonckheere test [1] for  randomized blocks which have dependent observations within block is presented. A weighted sum for each block statistic rather than the unweighted sum proposed by Jonckheereis included. For Jonckheere type statistics, the main assumption is independency of observations within block. In the case of repeated measures design, the assumption of independence is violated. The weighted Jonckheere type statistic for the situation of dependence for different variance-covariance structure and the situation based on ordered alternative hypothesis structure of each block on the design is used. Also, the proposed statistic is compared to the existing test based on Jonckheere in terms of type I error rates by performing Monte Carlo simulation. For the strong correlations, circular bootstrap version of the proposed Jonckheere test provides lower rates of type I error.

  10. Reproducibility and Reliability of Repeated Quantitative Fluorescence Angiography

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Knudsen, Kristine Bach Korsholm; Ambrus, Rikard

    2017-01-01

    INTRODUCTION: When using fluorescence angiography (FA) in perioperative perfusion assessment, repeated measures with re-injections of fluorescent dye (ICG) may be required. However, repeated injections may cause saturation of dye in the tissue, exceeding the limit of fluorescence intensity...... that the camera can detect. As the emission of fluorescence is dependent of the excitatory light intensity, reduction of this may solve the problem. The aim of the present study was to investigate the reproducibility and reliability of repeated quantitative FA during a reduction of excitatory light....

  11. Impact of Inclusion or Exclusion of Repeaters on Test Equating

    Science.gov (United States)

    Puhan, Gautam

    2011-01-01

    This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…

  12. Kinematic repeatability of a multi-segment foot model for dance.

    Science.gov (United States)

    Carter, Sarah L; Sato, Nahoko; Hopper, Luke S

    2018-03-01

    The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.

  13. EFFICIENCY OF REPEATED AND UNSCHEDULED TRAINING AS THE MEASURES TO PREVENT ACCIDENTS AT SUPPLY DEPOTS AND WAREHOUSES

    Directory of Open Access Journals (Sweden)

    Bocharova Irina Nikolaevna

    2013-05-01

    Full Text Available This paper presents the results of the analysis of the state of occupational safety at supply depots and warehouses. It is revealed that most accidents involve the employees who have less than one year’s service. Experience has proven that the preventive activities to avoid occupational traumatism are efficient when a complex of workplace safety measures is implemented. The experts consider the repeated and unscheduled training to be very important events. This is supported by the fact that among the employees of the commercial establishments who underwent repeated and unscheduled training, the number of individuals who suffered an accident is small. The efficient functioning of the occupational safety training system is infeasible without ensuring the motivation for assimilating the knowledge and forming the complete foundation for safe labor. In order to reduce the number of accidents, one should proceed from the principle of responding to accidents to the system for professional risk management.

  14. Examining Teacher Grades Using Rasch Measurement Theory

    Science.gov (United States)

    Randall, Jennifer; Engelhard, George, Jr.

    2009-01-01

    In this study, we present an approach to questionnaire design within educational research based on Guttman's mapping sentences and Many-Facet Rasch Measurement Theory. We designed a 54-item questionnaire using Guttman's mapping sentences to examine the grading practices of teachers. Each item in the questionnaire represented a unique student…

  15. Repeated wildfires alter forest recovery of mixed-conifer ecosystems.

    Science.gov (United States)

    Stevens-Rumann, Camille; Morgan, Penelope

    2016-09-01

    Most models project warmer and drier climates that will contribute to larger and more frequent wildfires. However, it remains unknown how repeated wildfires alter post-fire successional patterns and forest structure. Here, we test the hypothesis that the number of wildfires, as well as the order and severity of wildfire events interact to alter forest structure and vegetation recovery and implications for vegetation management. In 2014, we examined forest structure, composition, and tree regeneration in stands that burned 1-18 yr before a subsequent 2007 wildfire. Three important findings emerged: (1) Repeatedly burned forests had 15% less woody surface fuels and 31% lower tree seedling densities compared with forests that only experienced one recent wildfire. These repeatedly burned areas are recovering differently than sites burned once, which may lead to alternative ecosystem structure. (2) Order of burn severity (high followed by low severity compared with low followed by high severity) did influence forest characteristics. When low burn severity followed high, forests had 60% lower canopy closure and total basal area with 92% fewer tree seedlings than when high burn severity followed low. (3) Time between fires had no effect on most variables measured following the second fire except large woody fuels, canopy closure and tree seedling density. We conclude that repeatedly burned areas meet many vegetation management objectives of reduced fuel loads and moderate tree seedling densities. These differences in forest structure, composition, and tree regeneration have implications not only for the trajectories of these forests, but may reduce fire intensity and burn severity of subsequent wildfires and may be used in conjunction with future fire suppression tactics. © 2016 by the Ecological Society of America.

  16. The Enigma of Rapid Repeat Pregnancy: A Qualitative Study of Teen Mothers.

    Science.gov (United States)

    Conroy, K N; Engelhart, T G; Martins, Y; Huntington, N L; Snyder, A F; Coletti, K D; Cox, J E

    2016-06-01

    Rapid repeat pregnancy accounts for 18% of teen pregnancies and leads to adverse health, economic, and developmental outcomes for teen mothers and their children. Few interventions have been successful in reducing rapid repeat pregnancy. In this qualitative study we examined adolescent mothers' perceptions of their decision-making and behaviors that helped prevent or promote a rapid repeat pregnancy. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: Semistructured interviews were conducted with 31 adolescent mothers, aged 16-21 years; 15 of these subjects experienced a repeat pregnancy within a year of their first child's birth and 16 had not. Two researchers used a grounded, inductive technique to identify emergent themes; interviews were subsequently coded accordingly. Counts were tabulated of the number of times themes were endorsed among those with or without a repeat pregnancy. Four overarching themes emerged from the interviews: intentionality regarding pregnancy planning, patients' degree of independence in making contraceptive choices, sense of control over life experience, and barriers to follow-through on contraceptive planning. Teens who had not experienced a rapid repeat pregnancy more often endorsed themes of intentionality in preventing or promoting a pregnancy, independence in decision-making, and feelings of control over their experience. Ambivalence and lack of decision-making about seeking another pregnancy were frequently endorsed by mothers who had experienced a second pregnancy. Decision-making regarding seeking or preventing a rapid repeat pregnancy is complex for teen mothers; techniques to help support decision-making or to delay pregnancy until decision-repeat making is complete might be important in reducing rapid pregnancy. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  17. Reproducibility of tender point examination in chronic low back pain patients as measured by intrarater and inter-rater reliability and agreement

    DEFF Research Database (Denmark)

    Jensen, Ole Kudsk; Callesen, Jacob; Nielsen, Merete Graakjaer

    2013-01-01

    back examination and return-to-work intervention, 43 and 39 patients, respectively (18 women, 46%) entered and completed the study. MAIN OUTCOME MEASURES: The reliability was estimated by the intraclass correlation coefficient (ICC), and agreement was calculated for up to ±3 TPs. Furthermore......, the smallest detectable difference was calculated. RESULTS: TP examination was performed twice by two consultants in rheumatology and rehabilitation at 20 min intervals and repeated 1 week later. Intrarater reliability in the more and less experienced rater was ICC 0.84 (95% CI 0.69 to 0.98) and 0.72 (95% CI 0.......49 to 0.95), respectively. The figures for inter-rater reliability were intermediate between these figures. In more than 70% of the cases, the raters agreed within ±3 TPs in both men and women and between test days. The smallest detectable difference between raters was 5, and for the more and less...

  18. Temporal Alcohol Availability Predicts First-Time Drunk Driving, but Not Repeat Offending

    OpenAIRE

    Schofield, Timothy P.; Denson, Thomas F.

    2013-01-01

    Alcohol availability has been linked to drunk driving, but research has not examined whether this relationship is the same for first-time and repeat offenses. We examined the relationship between the business hours of alcohol outlets licensed to serve alcohol for on-premises consumption and misdemeanor-level (first offense) and felony-level drunk driving (repeat offense) charges in New York State in 2009. Longer outlet business hours were associated with more misdemeanor drunk driving charges...

  19. The repeatability of an intraoral dental colorimeter.

    Science.gov (United States)

    Tung, Francis F; Goldstein, Gary R; Jang, Sungkoo; Hittelman, Eugene

    2002-12-01

    Characterizing and reproducing color remain one of the most challenging aspects of dentistry. A relatively new intraoral colorimeter measures the color of natural teeth and metal-ceramic restorations and prints out a color recipe for the Vintage Halo Porcelain System. The reliability of the colorimeter is unknown. The purpose of this study was to evaluate the reliability of a contact dental colorimeter and to correlate the shade registered by the colorimeter with the shade selected by experienced clinicians. In part I of the study, 2 examiners (A and B) took 2 colorimeter measurements from the maxillary right central incisors of 11 subjects. The examiners were blinded to their own data and those of other investigators. The readings were repeated 3 weeks later with the same protocol. The Cronbach alpha reliability coefficient was used to analyze the collected data. In part II of the study, 2 experienced clinicians (examiners D and E) selected a shade from the classic Vita Lumin Vacuum shade guide for the maxillary right central incisors of the same 11 subjects. The clinicians were blinded to each other's selections and the colorimeter readings. It should be noted that the manufacturer of the colorimeter uses the terms shade, value, and hue to represent chroma, value, and hue, respectively, as defined in the Glossary of Prosthodontic Terms (J Prosthet Dent 1999;81:39-110). The reliability analysis results for each of the combined trials for shade, value, and hue were all >.94. The interexaminer reliability alpha values were >.9 for shade and value and.64 to.74 for hue. The interexaminer alpha represented the value range of each of 4 measurements. The intraexaminer reliability alpha values for shade, value, and hue were.99,.95, and.96 for examiner A and.99,.93, and.97 for examiner B, respectively. In part II of the study, the colorimeter agreed with itself 82% of the time, whereas clinicians agreed with each other on the selected shade 73% of the time. Selections made

  20. Quantum key distribution with two-segment quantum repeaters

    Energy Technology Data Exchange (ETDEWEB)

    Kampermann, Hermann; Abruzzo, Silvestre; Bruss, Dagmar [Theoretische Physik III, Heinrich-Heine-Universitaet Duesseldorf (Germany)

    2014-07-01

    Quantum repeaters represent one possible way to achieve long-distance quantum key distribution. One way of improving the repeater rate and decreasing the memory coherence time is the usage of multiplexing. Motivated by the experimental fact that long-range connections are practically demanding, we extend the analysis of the quantum repeater multiplexing protocol to the case of short-range connections. We derive formulas for the repeater rate and we show that short-range connections lead to most of the benefits of a full-range multiplexing protocol. A less demanding QKD-protocol without quantum memories was recently introduced by Lo et al. We generalize this measurement-device-independent quantum key Distribution protocol to the scenario where the repeater Station contains also heralded quantum memories. We assume either single-photon sources or weak coherent pulse sources plus decay states. We show that it is possible to significantly outperform the original proposal, even in presence of decoherence of the quantum memory. We give formulas in terms of device imperfections i.e., the quantum bit error rate and the repeater rate.

  1. Test-retest repeatability of strength capacity, aerobic power and pericranial tenderness of neck and shoulder muscles in children - relevant for tension-type headache

    DEFF Research Database (Denmark)

    Tornøe, Birte; Andersen, Lars L; Skotte, J H

    2013-01-01

    Frequent or chronic tension-type headache in children is a prevalent and debilitating condition for the child, often leading to medication overuse. To explore the relationship between physical factors and tension-type headache in children, the quality of repeated measures was examined. The aim of...... of the present study was to determine the test-retest repeatability of parameters determining isometric neck and shoulder strength and stability, aerobic power, and pericranial tenderness in children....

  2. The repeatability of interleukin-6, tumor necrosis factor-alpha, and C-reactive protein in COPD patients over one year

    DEFF Research Database (Denmark)

    Kolsum, Umme; Roy, Kay; Starkey, Cerys

    2009-01-01

    BACKGROUND: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD) are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and C-reactive protein......(i)) and the Bland-Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits. RESULTS: There was moderate repeatability with a very high degree of statistical significance (p...... (CRP) over one year and examined the relationships between these systemic markers in COPD. METHODS: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-alpha were measured. Repeatability was expressed by intraclass correlation coefficient (R...

  3. The repeatability of interleukin-6, tumor necrosis factor-alpha, and C-reactive protein in COPD patients over one year

    DEFF Research Database (Denmark)

    Kolsum, Umme; Roy, Kay; Starkey, Cerys

    2009-01-01

    BACKGROUND: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD) are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of Interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and C-reactive protein......(i)) and the Bland-Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits. RESULTS: There was moderate repeatability with a very high degree of statistical significance (p...... (CRP) over one year and examined the relationships between these systemic markers in COPD. METHODS: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-alpha were measured. Repeatability was expressed by intraclass correlation coefficient (R...

  4. Examining the stability of dual-task posture and reaction time measures in older adults over five sessions: a pilot study.

    Science.gov (United States)

    Jehu, Deborah A; Paquet, Nicole; Lajoie, Yves

    2016-12-01

    Improved performance may be inherent due to repeated exposure to a testing protocol. However, limited research has examined this phenomenon in postural control. The aim was to determine the influence of repeated administration of a dual-task testing protocol once per week for 5 weeks on postural sway and reaction time. Ten healthy older adults (67.0 ± 6.9 years) stood on a force plate for 30 s in feet apart and semi-tandem positions while completing simple reaction time (SRT) and choice reaction time (CRT) tasks. They were instructed to stand as still as possible while verbally responding as fast as possible to the stimuli. No significant differences in postural sway were shown over time (p > 0.05). A plateau in average CRT emerged as the time effect revealed longer CRT during session 1 compared to sessions 3-5 (p task context. Postural sway and SRT were stable over the 5 testing sessions, but variability of CRT continued to improve over time. These findings form a basis for future studies to examine performance-related improvements due to repeated exposure to a testing protocol in a dual-task setting.

  5. An Examination of Organizatinal Performance Measurement System Utilization

    OpenAIRE

    DeBusk, Gerald Kenneth

    2003-01-01

    This dissertation provides results of three studies, which examine the utilization of organizational performance measurement systems. Evidence gathered in the first study provides insight into the number of perspectives or components found in the evaluation of an organization's performance and the relative weight placed on those components. The evidence suggests that the number of performance measurement components and their relative composition is situational. Components depend heavily on th...

  6. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  7. Examination of offsite emergency protective measures for core melt accidents

    International Nuclear Information System (INIS)

    Aldrich, D.C.; McGrath, P.E.; Ericson, D.M. Jr.; Jones, R.B.; Rasmussen, N.C.

    Evacuation, sheltering followed by population relocation, and iodine prophylaxis are evaluated as offsite public protective measures in response to potential nuclear reactor accidents involving core-melt. Evaluations were conducted using a modified version of the Reactor Safety Study consequence model. Models representing each protective measure were developed and are discussed. Potential PWR core-melt radioactive material releases are separated into two categories, ''Melt-through'' and ''Atmospheric,'' based upon the mode of containment falure. Protective measures are examined and compared for each category in terms of projected doses to the whole body and thyroid. Measures for ''Atmospheric'' accidents are also examined in terms of their influence on the occurrence of public health effects

  8. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  9. Clinical examination, critical care ultrasonography and outcomes in the critically ill

    DEFF Research Database (Denmark)

    Hiemstra, Bart; Eck, Ruben J; Koster, Geert

    2017-01-01

    PURPOSE: In the Simple Intensive Care Studies-I (SICS-I), we aim to unravel the value of clinical and haemodynamic variables obtained by physical examination and critical care ultrasound (CCUS) that currently guide daily practice in critically ill patients. We intend to (1) measure all available...... patient used for guiding diagnostics, prognosis and interventions. Repeated evaluations of these sets of variables are needed for continuous improvement of the diagnostic and prognostic models. Future plans include: (1) more advanced imaging; (2) repeated clinical and haemodynamic measurements; (3...... clinical and haemodynamic variables, (2) train novices in obtaining values for advanced variables based on CCUS in the intensive care unit (ICU) and (3) create an infrastructure for a registry with the flexibility of temporarily incorporating specific (haemodynamic) research questions and variables...

  10. THICKNESS OF THE MACULA, RETINAL NERVE FIBER LAYER, AND GANGLION CELL-INNER PLEXIFORM LAYER IN THE AGE-RELATED MACULAR DEGENERATION: The Repeatability Study of Spectral Domain Optical Coherence Tomography.

    Science.gov (United States)

    Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul

    2018-02-01

    To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.

  11. Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values.

    Directory of Open Access Journals (Sweden)

    Tomohiro Kaneta

    Full Text Available Standardized uptake values (SUVs are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan. We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves

  12. Automated genotyping of dinucleotide repeat markers

    Energy Technology Data Exchange (ETDEWEB)

    Perlin, M.W.; Hoffman, E.P. [Carnegie Mellon Univ., Pittsburgh, PA (United States)]|[Univ. of Pittsburgh, PA (United States)

    1994-09-01

    The dinucleotide repeats (i.e., microsatellites) such as CA-repeats are a highly polymorphic, highly abundant class of PCR-amplifiable markers that have greatly streamlined genetic mapping experimentation. It is expected that over 30,000 such markers (including tri- and tetranucleotide repeats) will be characterized for routine use in the next few years. Since only size determination, and not sequencing, is required to determine alleles, in principle, dinucleotide repeat genotyping is easily performed on electrophoretic gels, and can be automated using DNA sequencers. Unfortunately, PCR stuttering with these markers generates not one band for each allele, but a pattern of bands. Since closely spaced alleles must be disambiguated by human scoring, this poses a key obstacle to full automation. We have developed methods that overcome this obstacle. Our model is that the observed data is generated by arithmetic superposition (i.e., convolution) of multiple allele patterns. By quantitatively measuring the size of each component band, and exploiting the unique stutter pattern associated with each marker, closely spaced alleles can be deconvolved; this unambiguously reconstructs the {open_quotes}true{close_quotes} allele bands, with stutter artifact removed. We used this approach in a system for automated diagnosis of (X-linked) Duchenne muscular dystrophy; four multiplexed CA-repeats within the dystrophin gene were assayed on a DNA sequencer. Our method accurately detected small variations in gel migration that shifted the allele size estimate. In 167 nonmutated alleles, 89% (149/167) showed no size variation, 9% (15/167) showed 1 bp variation, and 2% (3/167) showed 2 bp variation. We are currently developing a library of dinucleotide repeat patterns; together with our deconvolution methods, this library will enable fully automated genotyping of dinucleotide repeats from sizing data.

  13. Learning With Repeated-Game Strategies

    Directory of Open Access Journals (Sweden)

    Christos A. Ioannou

    2014-07-01

    Full Text Available We use the self-tuning Experience Weighted Attraction model with repeated-game strategies as a computer testbed to examine the relative frequency, speed of convergence and progression of a set of repeated-game strategies in four symmetric 2x2 games: Prisoner's Dilemma, Battle of the Sexes, Stag-Hunt, and Chicken. In the Prisoner's Dilemma game, we fi□nd that the strategy with the most occurrences is the Grim-Trigger. In the Battle of the Sexes game, a cooperative pair that alternates between the two pure-strategy Nash equilibria emerges as the one with the most occurrences. In the Stag-Hunt and Chicken games, the Win-Stay, Lose-Shift and Grim-Trigger strategies are the ones with the most occurrences. Overall, the pairs that converged quickly ended up at the cooperative outcomes, whereas the ones that were extremely slow to reach convergence ended up at non-cooperative outcomes.

  14. A COMPARISON OF PAIRS FIGURE SKATERS IN REPEATED JUMPS

    Directory of Open Access Journals (Sweden)

    William A. Sands

    2012-03-01

    Full Text Available Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare

  15. Does repeat Hb measurement within 2 hours after a normal initial Hb in stable trauma patients add value to trauma evaluation?

    NARCIS (Netherlands)

    Sierink, Joanne C.; Joosse, Pieter; de Castro, Steve M. M.; Schep, Niels W. L.; Goslings, J. Carel

    2014-01-01

    In our level I trauma center, it is considered common practice to repeat blood haemoglobin measurements in patients within 2 h after admission. However, the rationale behind this procedure is elusive and can be considered labour-intensive, especially in patients in whom haemorrhaging is not to be

  16. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients...... with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...... macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm...

  17. Repeat cesarean delivery: what indications are recorded in the medical chart?

    Science.gov (United States)

    Lydon-Rochelle, Mona T; Gardella, Carolyn; Cárdenas, Vicky; Easterling, Thomas R

    2006-03-01

    National surveillance estimates reported a troubling 63 percent decline in the rate of vaginal birth after cesarean delivery (VBAC) from 1996 (28.3%) to 2003 (10.6%), with subsequent rising rates of repeat cesarean delivery. The study objective was to examine patterns of documented indications for repeat cesarean delivery in women with and without labor. We conducted a population-based validation study of 19 nonfederal short-stay hospitals in Washington state. Of the 4,541 women who had live births in 2000, 11 percent (n = 493) had repeat cesarean without labor and 3 percent (n = 138) had repeat cesarean with labor. Incidence of medical conditions and pregnancy complications, patterns of documented indications for repeat cesarean delivery, and perioperative complications in relation to repeat cesarean delivery with and without labor were calculated. Of the 493 women who underwent a repeat cesarean delivery without labor, "elective"(36%) and "maternal request"(18%) were the most common indications. Indications for maternal medical conditions (3.0%) were uncommon. Among the 138 women with repeat cesarean delivery with labor, 60.1 percent had failure to progress, 24.6 percent a non-reassuring fetal heart rate, 8.0 percent cephalopelvic disproportion, and 7.2 percent maternal request during labor. Fetal indications were less common (5.8%). Breech, failed vacuum, abruptio placentae, maternal complications, and failed forceps were all indicated less than 5.0 percent. Women's perioperative complications did not vary significantly between women without and with labor. Regardless of a woman's labor status, nearly 10 percent of women with repeat cesarean delivery had no documented indication as to why a cesarean delivery was performed. "Elective" and "maternal request" were common indications among women undergoing repeat cesarean delivery without labor, and nearly 10 percent of women had undocumented indications for repeat cesarean delivery in their medical record

  18. Accuracy of repeated kidney size estimation by ultrasonography and urography in children

    International Nuclear Information System (INIS)

    Hederstroem, E.; Forsberg, L.

    1985-01-01

    The accuracy of repeated sonographic and urographic kidney length measurements in kidney size evaluation was investigated in 80 children 0 to 14 years of age, mean age 4.5 years. At sonography 250 kidney lengths were compared. A difference of 0 to 1.0 cm in repeated length measurement was considered to be good accuracy and 94 per cent of right and 96 per cent of left kidney length were found within this interval-a better result than for urography with 76 per cent of repeated right kidney and 79 per cent of kidney lengths within the same interval (94 lengths). Both methods display a variation of kidney lengths which may lead to under- and overestimation of kidney size and growth. The investigation thus indicates good accuracy for repeated sonographic kidney size assessment which should be repeated often enough to estabilish a growth chart displaying the trend rather than rely too much on single measurements. Sonography can be highly recommended as a convenient and harmless alternative to urography. (orig.)

  19. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  20. Layered Architectures for Quantum Computers and Quantum Repeaters

    Science.gov (United States)

    Jones, Nathan C.

    This chapter examines how to organize quantum computers and repeaters using a systematic framework known as layered architecture, where machine control is organized in layers associated with specialized tasks. The framework is flexible and could be used for analysis and comparison of quantum information systems. To demonstrate the design principles in practice, we develop architectures for quantum computers and quantum repeaters based on optically controlled quantum dots, showing how a myriad of technologies must operate synchronously to achieve fault-tolerance. Optical control makes information processing in this system very fast, scalable to large problem sizes, and extendable to quantum communication.

  1. Temporal alcohol availability predicts first-time drunk driving, but not repeat offending.

    Science.gov (United States)

    Schofield, Timothy P; Denson, Thomas F

    2013-01-01

    Alcohol availability has been linked to drunk driving, but research has not examined whether this relationship is the same for first-time and repeat offenses. We examined the relationship between the business hours of alcohol outlets licensed to serve alcohol for on-premises consumption and misdemeanor-level (first offense) and felony-level drunk driving (repeat offense) charges in New York State in 2009. Longer outlet business hours were associated with more misdemeanor drunk driving charges, but were not associated with felony drunk driving charges. The per capita density of on-premises alcohol outlets did not affect misdemeanor or felony drunk driving charges. The results suggest that temporal alcohol availability may be an impelling factor for first-time drunk driving, but other factors likely influence repeat drunk driving behaviors.

  2. Temporal alcohol availability predicts first-time drunk driving, but not repeat offending.

    Directory of Open Access Journals (Sweden)

    Timothy P Schofield

    Full Text Available Alcohol availability has been linked to drunk driving, but research has not examined whether this relationship is the same for first-time and repeat offenses. We examined the relationship between the business hours of alcohol outlets licensed to serve alcohol for on-premises consumption and misdemeanor-level (first offense and felony-level drunk driving (repeat offense charges in New York State in 2009. Longer outlet business hours were associated with more misdemeanor drunk driving charges, but were not associated with felony drunk driving charges. The per capita density of on-premises alcohol outlets did not affect misdemeanor or felony drunk driving charges. The results suggest that temporal alcohol availability may be an impelling factor for first-time drunk driving, but other factors likely influence repeat drunk driving behaviors.

  3. Postural adaptations to repeated optic flow stimulation in older adults

    Science.gov (United States)

    O’Connor, Kathryn W.; Loughlin, Patrick J.; Redfern, Mark S.; Sparto, Patrick J.

    2008-01-01

    The purpose of this study is to understand the processes of adaptation (changes in within-trial postural responses) and habituation (reductions in between-trial postural responses) to visual cues in older and young adults. Of particular interest were responses to sudden increases in optic flow magnitude. The postural sway of 25 healthy young adults and 24 healthy older adults was measured while subjects viewed anterior-posterior 0.4 Hz sinusoidal optic flow for 45 s. Three trials for each of three conditions were performed: 1) constant 12 cm optic flow amplitude (24 cm peak-to-peak), 2) constant 4 cm amplitude (8 cm p-t-p), and 3) a transition in amplitude from 4 to 12 cm. The average power of head sway velocity (Pvel) was calculated for consecutive 5 s intervals during the trial to examine the changes in sway within and between trials. A mixed factor repeated measures ANOVA was performed to examine the effects of subject Group, Trial, and Interval on the Pvel. Pvel was greater in older adults in all conditions (p Pvel of the older adults decreased significantly between all 3 trials, but decreased only between trial 1 and 2 in young adults. While the responses of the young adults to the transition in optic flow from 4 to 12 cm did not significantly change, older adults had an increase in Pvel following the transition, ranging from 6.5 dB for the first trial to 3.4 dB for the third trial. These results show that older adults can habituate to repeated visual perturbation exposures; however, this habituation requires a greater number of exposures than young adults. This suggests aging impacts the ability to quickly modify the relative weighting of the sensory feedback for postural stabilization. PMID:18329878

  4. Examining impulse-variability in overarm throwing.

    Science.gov (United States)

    Urbin, M A; Stodden, David; Boros, Rhonda; Shannon, David

    2012-01-01

    The purpose of this study was to examine variability in overarm throwing velocity and spatial output error at various percentages of maximum to test the prediction of an inverted-U function as predicted by impulse-variability theory and a speed-accuracy trade-off as predicted by Fitts' Law Thirty subjects (16 skilled, 14 unskilled) were instructed to throw a tennis ball at seven percentages of their maximum velocity (40-100%) in random order (9 trials per condition) at a target 30 feet away. Throwing velocity was measured with a radar gun and interpreted as an index of overall systemic power output. Within-subject throwing velocity variability was examined using within-subjects repeated-measures ANOVAs (7 repeated conditions) with built-in polynomial contrasts. Spatial error was analyzed using mixed model regression. Results indicated a quadratic fit with variability in throwing velocity increasing from 40% up to 60%, where it peaked, and then decreasing at each subsequent interval to maximum (p < .001, η2 = .555). There was no linear relationship between speed and accuracy. Overall, these data support the notion of an inverted-U function in overarm throwing velocity variability as both skilled and unskilled subjects approach maximum effort. However, these data do not support the notion of a speed-accuracy trade-off. The consistent demonstration of an inverted-U function associated with systemic power output variability indicates an enhanced capability to regulate aspects of force production and relative timing between segments as individuals approach maximum effort, even in a complex ballistic skill.

  5. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    Science.gov (United States)

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  6. Proactive behavior, but not inhibitory control, predicts repeated innovation by spotted hyenas tested with a multi-access box.

    Science.gov (United States)

    Johnson-Ulrich, Lily; Johnson-Ulrich, Zoe; Holekamp, Kay

    2018-05-01

    Innovation is widely linked to cognitive ability, brain size, and adaptation to novel conditions. However, successful innovation appears to be influenced by both cognitive factors, such as inhibitory control, and non-cognitive behavioral traits. We used a multi-access box (MAB) paradigm to measure repeated innovation, the number of unique innovations learned across trials, by 10 captive spotted hyenas (Crocuta crocuta). Spotted hyenas are highly innovative in captivity and also display striking variation in behavioral traits, making them good model organisms for examining the relationship between innovation and other behavioral traits. We measured persistence, motor diversity, motivation, activity, efficiency, inhibitory control, and neophobia demonstrated by hyenas while interacting with the MAB. We also independently assessed inhibitory control with a detour cylinder task. Most hyenas were able to solve the MAB at least once, but only four hyenas satisfied learning criteria for all four possible solutions. Interestingly, neither measure of inhibitory control predicted repeated innovation. Instead, repeated innovation was predicted by a proactive syndrome of behavioral traits that included high persistence, high motor diversity, high activity and low neophobia. Our results suggest that this proactive behavioral syndrome may be more important than inhibitory control for successful innovation with the MAB by members of this species.

  7. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  8. Precision of high definition spectral-domain optical coherence tomography for measuring central corneal thickness.

    Science.gov (United States)

    Correa-Pérez, María E; López-Miguel, Alberto; Miranda-Anta, Silvia; Iglesias-Cortiñas, Darío; Alió, Jorge L; Maldonado, Miguel J

    2012-04-06

    This study was intended to assess the reliability of central corneal thickness (CCT) measurements using Cirrus high-definition optical coherence tomography (HD-OCT) in healthy subjects and its accuracy compared with ultrasonic pachymetry. Seventy-seven consecutive subjects were recruited for evaluating repeatability, and agreement between two examiners. To analyze repeatability, one examiner measured 77 eyes four times in succession. To study agreement between two observers, a second independently trained examiner obtained another CCT measurement. We also measured eyes in a subgroup of 20 patients using standard ultrasonic pachymetry. Within-subject standard deviation (S(w)), coefficient of variation (CV), limits of agreement (LoA), and intraclass correlation coefficient (ICC) data were obtained. For repeatability, the S(w) and precision (1.96 × S(w)) were 4.86 and 9.52 μm, respectively. Intraobserver CV was 0.89% and the ICC was 0.98 (95% confidence interval [CI], 0.97-0.99). For agreement between two examiners, the S(w) and precision were 7.58 and 14.85 μm, respectively; the CV was 1.40%. The mean difference between observers was -0.13 μm (95% CI, -1.85 to 1.58; P = 0.87). The width of the LoA was 29.64 μm. Median difference between Cirrus HD-OCT and ultrasound CCT measurements was -4.5 μm (interquartile range, -7.0-0.0; P = 0.04). Cirrus HD-OCT provides repeatable CCT measurements, good agreement between two independently trained examiners, and its systematic bias compared to ultrasonic pachymetry is clinically negligible. Therefore, research laboratories and eye clinics using Cirrus HD-OCT as a diagnostic imaging method, can also benefit from a reliable noncontact pachymeter when counseling patients with glaucoma and those undergoing corneal and refractive surgeries.

  9. Psychological and physiological responses following repeated peer death.

    Directory of Open Access Journals (Sweden)

    Judith Pizarro Andersen

    Full Text Available Undergraduates at a university in the United States were exposed - directly and indirectly - to 14 peer deaths during one academic year. We examined how individual and social factors were associated with psychological (e.g., anxiety, depression, somatization and physiological (i.e., cortisol distress responses following this unexpected and repeated experience with loss.Two to three months after the final peer death, respondents (N = 122, 61% female, 18-23 years, M = 20.13, SD = 1.14 reported prior adverse experiences, degree of closeness with the deceased, acute responses to the peer deaths, ongoing distress responses, social support, support seeking, and media viewing. A subset (n = 24 returned hair samples for evaluation of cortisol responses during the previous 3 months.Ongoing psychological distress was associated with a prior interpersonal trauma, b fewer social supports, and c media exposure to news of the deaths (p's25 p/mg compared to individuals with one or two prior bereavement experiences (who were, on average, within the normal range, 10 to 25 p/mg (p<.05. Only 8% of the sample utilized available university psychological or physical health resources and support groups.Limited research has examined the psychological and physiological impact of exposure to chronic, repeated peer loss, despite the fact that there are groups of individuals (e.g., police, military soldiers that routinely face such exposures. Prior adversity appears to play a role in shaping psychological and physiological responses to repeated loss. This topic warrants further research given the health implications of repeated loss for individuals in high-risk occupations and university settings.

  10. Do repeated rumble strip hits improve driver alertness?

    NARCIS (Netherlands)

    Watling, C.N.; Akerstedt, T.; Kecklund, L.G.; Anund, A.

    2016-01-01

    Driving while sleepy is associated with increased crash risk. Rumble strips are designed to alert a sleepy or inattentive driver when they deviate outside their driving lane. The current study sought to examine the effects of repeated rumble strip hits on levels of physiological and subjective

  11. Aging, recall and recognition: a study on the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT).

    Science.gov (United States)

    Parker, Elizabeth S; Landau, Susan M; Whipple, Stephen C; Schwartz, Barbara L

    2004-05-01

    This study examines the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT) to the effects of aging in a sample of 112 men and women from 18 to 93 years old. Two new recognition measures, yes-no and forced-choice, were developed to supplement the original USC-REMT which measured only free-recall. Free-recall, yes-no recognition and forced-choice recognition were sensitive to age effects, with free-recall being the most sensitive. The seven recall and recognition lists can be used interchangeably. The data indicate that the USC-REMT is worthy of consideration when there is a need for a brief, screening tool of various memory functions, particularly when there is interest in memory changes over time and repeated assessments.

  12. Potentials and limitations of histone repeat sequences for phylogenetic reconstruction of Sophophora.

    Science.gov (United States)

    Baldo, A M; Les, D H; Strausbaugh, L D

    1999-11-01

    Simplified DNA sequence acquisition has provided many new data sets that are useful for phylogenetic reconstruction, including single- and multiple-copy nuclear and organellar genes. Although transcribed regions receive much attention, nontranscribed regions have recently been added to the repertoire of sequences suitable for phylogenetic studies, especially for closely related taxa. We evaluated the efficacy of a small portion of the histone repeat for phylogenetic reconstruction among Drosophila species. Histone repeats in invertebrates offer distinct advantages similar to those of widely used ribosomal repeats. First, the units are tandemly repeated and undergo concerted evolution. Second, histone repeats include both highly conserved coding and variable intergenic regions. This composition facilitates application of "universal" primers spanning potentially informative sites. We examined a small region of the histone repeat, including the intergenic spacer segments of coding regions from the divergently transcribed H2A and H2B histone genes. The spacer (about 230 bp) exists as a mosaic with highly conserved functional motifs interspersed with rapidly diverging regions; the former aid in alignment of the spacer. There are no ambiguities in alignment of coding regions. Coding and noncoding regions were analyzed together and separately for phylogenetic information. Parsimony, distance, and maximum-likelihood methods successfully retrieve the corroborated phylogeny for the taxa examined. This study demonstrates the resolving power of a small histone region which may now be added to the growing collection of phylogenetically useful DNA sequences.

  13. Safety of Repeated Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Louie, John D.; Iagaru, Andrei H.; Goris, Michael L.; Sze, Daniel Y.

    2013-01-01

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver’s cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51–71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction

  14. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  15. Who Repeats Algebra, and How Does Initial Performance Relate to Improvement When the Course Is Repeated?

    Science.gov (United States)

    Fong, Anthony; Jaquet, Karina; Finkelstein, Neal

    2016-01-01

    The information provided in this report shows how students perform when they repeat algebra I and how the level of improvement varies depending on initial course performance and the academic measure (course grades or CST scores). This information can help inform decisions and policies regarding whether and under what circumstances students should…

  16. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    Science.gov (United States)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    Traditional methodologies for measuring ratios of stable isotopes within the xylem water of trees involve destructive coring of the stem. A recent approach involves permanently installed probes within the stem, and an on-site assembly of pumps, switching valves, gas lines, and climate-controlled structure for field deployment of a laser spectrometer. The former method limits the possible temporal resolution of sampling, and sample size, while the latter may not be feasible for many research groups. We present results from initial laboratory efforts towards developing a non-destructive, temporally-resolved technique for measuring stable isotope ratios within the xylem flow of trees. Researchers have used direct liquid-vapor equilibration as a method to measure isotope ratios of the water in soil pores. Typically, this is done by placing soil samples in a fixed container, and allowing the liquid water within the soil to come into isotopic equilibrium with the headspace of the container. Water can also be removed via cryogenic distillation or azeotropic distillation, with the resulting liquid tested for isotope ratios. Alternatively, the isotope ratios of the water vapor can be directly measured using a laser-based water vapor isotope analyzer. Well-established fractionation factors and the isotope ratios in the vapor phase are then used to calculate the isotope ratios in the liquid phase. We propose a setup which would install a single, removable chamber onto a tree, where vapor samples could non-destructively and repeatedly be taken. These vapor samples will be injected into a laser-based isotope analyzer by a recirculating gas conveyance system. A major part of what is presented here is in the procedure of taking vapor samples at 100% relative humidity, appropriately diluting them with completely dry N2 calibration gas, and injecting them into the gas conveyance system without inducing fractionation in the process. This methodology will be helpful in making

  17. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  18. Governing conditions of repeatable Barkhausen noise response

    International Nuclear Information System (INIS)

    Stupakov, O.; Pal'a, J.; Takagi, T.; Uchimoto, T.

    2009-01-01

    The paper is devoted to the establishment of experimental conditions, which ensure the repeatability of magnetic Barkhausen noise testing in practice. For this task, the measurements were performed on open flat samples using different experimental configurations, including: different magnetization frequencies, sampling rates, and filter cut-off frequencies; using a sample-wrapped coil and using attached pick-up coils of various dimensions, with different lift-offs of a single yoke magnet and of the attached coil. The sample magnetization was controlled by a vertical array of three Hall sensors; their readings were extrapolated to the sample surface to precisely define its field. After analysis of the results, a scheme for an optimized sensor with a controlled field waveform was suggested to improve the measurement repeatability. The important issues of signal processing and parameter applicability were also discussed in detail.

  19. A pilot study examining density of suppression measurement in strabismus.

    Science.gov (United States)

    Piano, Marianne; Newsham, David

    2015-01-01

    Establish whether the Sbisa bar, Bagolini filter (BF) bar, and neutral density filter (NDF) bar, used to measure density of suppression, are equivalent and possess test-retest reliability. Determine whether density of suppression is altered when measurement equipment/testing conditions are changed. Our pilot study had 10 subjects aged ≥18 years with childhood-onset strabismus, no ocular pathologies, and no binocular vision when manifest. Density of suppression upon repeated testing, with clinic lights on/off, and using a full/reduced intensity light source, was investigated. Results were analysed for test-retest reliability, equivalence, and changes with alteration of testing conditions. Test-retest reliability issues were present for the BF bar (median 6 filter change from first to final test, p = 0.021) and NDF bar (median 5 filter change from first to final test, p = 0.002). Density of suppression was unaffected by environmental illumination or fixation light intensity variations. Density of suppression measurements were higher when measured with the NDF bar (e.g. NDF bar = 1.5, medium suppression, vs BF bar = 6.5, light suppression). Test-retest reliability issues may be present for the two filter bars currently still under manufacture. Changes in testing conditions do not significantly affect test results, provided the same filter bar is used consistently for testing. Further studies in children with strabismus having active amblyopia treatment would be of benefit. Despite extensive use of these tests in the UK, this is to our knowledge the first study evaluating filter bar equivalence/reliability.

  20. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    Science.gov (United States)

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  1. RNA FISH for detecting expanded repeats in human diseases.

    Science.gov (United States)

    Urbanek, Martyna O; Krzyzosiak, Wlodzimierz J

    2016-04-01

    RNA fluorescence in situ hybridization (FISH) is a widely used technique for detecting transcripts in fixed cells and tissues. Many variants of RNA FISH have been proposed to increase signal strength, resolution and target specificity. The current variants of this technique facilitate the detection of the subcellular localization of transcripts at a single molecule level. Among the applications of RNA FISH are studies on nuclear RNA foci in diseases resulting from the expansion of tri-, tetra-, penta- and hexanucleotide repeats present in different single genes. The partial or complete retention of mutant transcripts forming RNA aggregates within the nucleoplasm has been shown in multiple cellular disease models and in the tissues of patients affected with these atypical mutations. Relevant diseases include, among others, myotonic dystrophy type 1 (DM1) with CUG repeats, Huntington's disease (HD) and spinocerebellar ataxia type 3 (SCA3) with CAG repeats, fragile X-associated tremor/ataxia syndrome (FXTAS) with CGG repeats, myotonic dystrophy type 2 (DM2) with CCUG repeats, amyotrophic lateral sclerosis/frontotemporal dementia (ALS/FTD) with GGGGCC repeats and spinocerebellar ataxia type 32 (SCA32) with GGCCUG. In this article, we summarize the results obtained with FISH to examine RNA nuclear inclusions. We provide a detailed protocol for detecting RNAs containing expanded CAG and CUG repeats in different cellular models, including fibroblasts, lymphoblasts, induced pluripotent stem cells and murine and human neuronal progenitors. We also present the results of the first single-molecule FISH application in a cellular model of polyglutamine disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    International Nuclear Information System (INIS)

    Bagchi, Manjari

    2017-01-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  3. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Bagchi, Manjari, E-mail: manjari@imsc.res.in [The Institute of Mathematical Sciences (IMSc-HBNI), 4th Cross Road, CIT Campus, Taramani, Chennai 600113 (India)

    2017-04-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  4. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  5. Exploring antecedents of consumer satisfaction and repeated search behavior on e-health information.

    Science.gov (United States)

    Lee, Yun Jung; Park, Jungkun; Widdows, Richard

    2009-03-01

    E-health information has become an important resource for people seeking health information. Even though many studies have been conducted to examine the quality of e-health information, only a few studies have explored the effects of the information seekers' motivations on the perceived quality of e-health information. There is even less information about repeated searches for e-health information after the users' initial experience of e-health information use. Using an online survey of information seekers, 252 e-health information users' responses were collected. The research examines the relationship among motivation, perceived quality, satisfaction, and intention to repeat-search e-health information. The results identify motivations to search e-health information and confirm the relationship among motivation, perceived quality dimensions, and satisfaction and intention to repeat searches for e-health information.

  6. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    Science.gov (United States)

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  7. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  8. Overcoming fixation with repeated memory suppression.

    Science.gov (United States)

    Angello, Genna; Storm, Benjamin C; Smith, Steven M

    2015-01-01

    Fixation (blocks to memories or ideas) can be alleviated not only by encouraging productive work towards a solution, but, as the present experiments show, by reducing counterproductive work. Two experiments examined relief from fixation in a word-fragment completion task. Blockers, orthographically similar negative primes (e.g., ANALOGY), blocked solutions to word fragments (e.g., A_L_ _GY) in both experiments. After priming, but before the fragment completion test, participants repeatedly suppressed half of the blockers using the Think/No-Think paradigm, which results in memory inhibition. Inhibiting blockers did not alleviate fixation in Experiment 1 when conscious recollection of negative primes was not encouraged on the fragment completion test. In Experiment 2, however, when participants were encouraged to remember negative primes at fragment completion, relief from fixation was observed. Repeated suppression may nullify fixation effects, and promote creative thinking, particularly when fixation is caused by conscious recollection of counterproductive information.

  9. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  10. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  11. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  12. Thermotactile perception thresholds measurement conditions.

    Science.gov (United States)

    Maeda, Setsuo; Sakakibara, Hisataka

    2002-10-01

    The purpose of this paper is to investigate the effects of posture, push force and rate of temperature change on thermotactile thresholds and to clarify suitable measuring conditions for Japanese people. Thermotactile (warm and cold) thresholds on the right middle finger were measured with an HVLab thermal aesthesiometer. Subjects were eight healthy male Japanese students. The effects of posture in measurement were examined in the posture of a straight hand and forearm placed on a support, the same posture without a support, and the fingers and hand flexed at the wrist with the elbow placed on a desk. The finger push force applied to the applicator of the thermal aesthesiometer was controlled at a 0.5, 1.0, 2.0 and 3.0 N. The applicator temperature was changed to 0.5, 1.0, 1.5, 2.0 and 2.5 degrees C/s. After each measurement, subjects were asked about comfort under the measuring conditions. Three series of experiments were conducted on different days to evaluate repeatability. Repeated measures ANOVA showed that warm thresholds were affected by the push force and the rate of temperature change and that cold thresholds were influenced by posture and push force. The comfort assessment indicated that the measurement posture of a straight hand and forearm laid on a support was the most comfortable for the subjects. Relatively high repeatability was obtained under measurement conditions of a 1 degrees C/s temperature change rate and a 0.5 N push force. Measurement posture, push force and rate of temperature change can affect the thermal threshold. Judging from the repeatability, a push force of 0.5 N and a temperature change of 1.0 degrees C/s in the posture with the straight hand and forearm laid on a support are recommended for warm and cold threshold measurements.

  13. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  14. The effectiveness of eye-closure in repeated interviews

    OpenAIRE

    Vredeveldt, A.; Baddeley, A.D.; Hitch, G.J.

    2014-01-01

    Purpose Closing the eyes during recall can help witnesses remember more about a witnessed event. This study examined the effectiveness of eye-closure in a repeated recall paradigm with immediate free recall followed 1 week later by both free and cued recall. We examined whether eye-closure was more or less effective during the second free-recall attempt compared with the first, whether eye-closure during the first recall attempt had an impact on subsequent free- and cued-recall performance, a...

  15. An examination of the parametric properties of four noise sensitivity measures

    DEFF Research Database (Denmark)

    van Kamp, Irene; Ellermeier, Wolfgang; Lopez-Barrio, Isabel

    2006-01-01

    Noise sensitivity (NS) is a personality trait with a strong influence on reactions to noise. Studies of reaction should include a standard measure of NS that is founded on a theoretically justified definition of NS, and examination of existing NS measures' parametric properties (internal consiste......, demographics and lifestyle). A standard NS measure should demonstrate high reliability, and should predict responses to noise. Discussion is welcomed and will focus on validation strategies and optimizing the study design.......Noise sensitivity (NS) is a personality trait with a strong influence on reactions to noise. Studies of reaction should include a standard measure of NS that is founded on a theoretically justified definition of NS, and examination of existing NS measures' parametric properties (internal...... consistency; stability; convergent and predictive validity). At each of 6 laboratory centres (Aalborg; London; Sydney; Dortmund; Madrid, Amsterdam), participants will complete four NS measures on each of two occasions. In one occasion, participants will complete a task while exposed to recorded aircraft noise...

  16. Repeated oral administration of capsaicin increases anxiety-like ...

    Indian Academy of Sciences (India)

    This study was conducted to examine the psycho-emotional effects of repeated oral exposure to capsaicin, the principal active component of chili peppers. Each rat received 1 mL of 0.02% capsaicin into its oral cavity daily, and was subjected to behavioural tests following 10 daily administrations of capsaicin. Stereotypy ...

  17. Improvement of Repeated-Sprint Ability and Horizontal-Jumping Performance in Elite Young Basketball Players With Low-Volume Repeated-Maximal-Power Training.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Tous-Fajardo, Julio; Arjol-Serrano, José Luis; Suarez-Arrones, Luis; Casajús, José Antonio; Mendez-Villanueva, Alberto

    2016-05-01

    To examine the effects of a low-volume repeated-power-ability (RPA) training program on repeated-sprint and change-of- direction (COD) ability and functional jumping performance. Twenty-two male elite young basketball players (age 16.2 ± 1.2 y, height 190.0 ± 10.0 cm, body mass 82.9 ± 10.1 kg) were randomly assigned either to an RPA-training group (n = 11) or a control group (n = 11). RPA training consisted of leg-press exercise, twice a week for 6 wk, of 1 or 2 blocks of 5 sets × 5 repetitions with 20 s of passive recovery between sets and 3 min between blocks with the load that maximized power output. Before and after training, performance was assessed by a repeated-sprint-ability (RSA) test, a repeated-COD-ability test, a hop for distance, and a drop jump followed by tests of a double unilateral hop with the right and left legs. Within-group and between-groups differences showed substantial improvements in slowest (RSAs) and mean time (RSAm) on RSA; best, slowest and mean time on repeated-COD ability; and unilateral right and left hop in the RPA group in comparison with control. While best time on RSA showed no improvement in any group, there was a large relationship (r = .68, 90% CI .43;.84) between the relative decrement in RSAm and RSAs, suggesting better sprint maintenance with RPA training. The relative improvements in best and mean repeated-COD ability were very largely correlated (r = .89, 90% CI .77;.94). Six weeks of lowvolume (4-14 min/wk) RPA training improved several physical-fitness tests in basketball players.

  18. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  19. TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Y; Fuller, C; Mohamed, A; Wang, J; Hazle, J [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients were scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.

  20. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  1. Warm magnetic measurements of MCBCs: comparison between the results obtained with the Quadrupole Industrial Magnetic Measurement and the Corrector Industrial Magnetic Measurement systems

    CERN Document Server

    Remondino, Vittorio; Catalan-Lasheras, N

    2005-01-01

    MCBCs modules are first magnetically measured at Tesla using a second-generation Corrector Industrial Magnetic Measurement (CIMM). After assembly into the SSS quadrupoles, measurements are repeated at CERN using the Quadrupole Industrial Magnetic Measurement (QIMM) system. In this note, we compare the measurements provided by the two systems. In all the 18 cases examined, the correlation found is excellent. The consistency of the results obtained indicates that both systems are effective, that modules are correctly measured by the firm personnel and that magnetic characteristics of the modules do not change during their assembly in cold masses.

  2. Poor methodological detail precludes experimental repeatability and hampers synthesis in ecology.

    Science.gov (United States)

    Haddaway, Neal R; Verhoeven, Jos T A

    2015-10-01

    Despite the scientific method's central tenets of reproducibility (the ability to obtain similar results when repeated) and repeatability (the ability to replicate an experiment based on methods described), published ecological research continues to fail to provide sufficient methodological detail to allow either repeatability of verification. Recent systematic reviews highlight the problem, with one example demonstrating that an average of 13% of studies per year (±8.0 [SD]) failed to report sample sizes. The problem affects the ability to verify the accuracy of any analysis, to repeat methods used, and to assimilate the study findings into powerful and useful meta-analyses. The problem is common in a variety of ecological topics examined to date, and despite previous calls for improved reporting and metadata archiving, which could indirectly alleviate the problem, there is no indication of an improvement in reporting standards over time. Here, we call on authors, editors, and peer reviewers to consider repeatability as a top priority when evaluating research manuscripts, bearing in mind that legacy and integration into the evidence base can drastically improve the impact of individual research reports.

  3. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    Directory of Open Access Journals (Sweden)

    Rohit Shetty

    2017-01-01

    Full Text Available Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL haze on the measurement and repeatability of pachymetry and mean keratometry (Km of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL underwent imaging with a scanning slit imaging device (Orbscan II and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei. Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05 significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively. Km values were affected by haze when measured with the Pentacam HR (P < 0.05. The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively, Km values (P = 0.4 and 0.6, respectively, repeatability of TCT (P = 0.1 in both zones, and Km (P = 0.5 and 0.1, respectively with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution.

  4. Repeated transsphenoidal surgery or gamma knife radiosurgery in recurrent cushing disease after transsphenoidal surgery.

    Science.gov (United States)

    Bodaghabadi, Mohammad; Riazi, Hooman; Aran, Shima; Bitaraf, Mohammad Ali; Alikhani, Mazdak; Alahverdi, Mahmud; Mohamadi, Masoumeh; Shalileh, Keivan; Azar, Maziar

    2014-03-01

    This study compared Gamma knife radiosurgery (GKRS) and repeated transsphenoidal adenomectomy (TSA) to find the best approach for recurrence of Cushing disease (CD) after unsuccessful first TSA. Fifty-two patients with relapse of CD after TSA were enrolled and randomly underwent a second surgery or GKRS as the next therapeutic approach. They were followed for a mean period of 3.05 ± 0.8 years by physical examination and hormone measurement as well as magnetic resonance imaging. No significant difference was observed in sex ratio, mean age, adenoma type, follow-up duration, and initial hormone level between the two groups. No significant relationship was found between preoperative 24-hour free urine cortisol and disease-free months or tumor volume among both groups. Our statistical analysis showed higher recurrence-free interval in the GKRS group compared with TSA group. With longer recurrence-free interval, GKRS could be considered a good treatment alternative to repeated TSA in recurrent CD. Georg Thieme Verlag KG Stuttgart · New York.

  5. Correlation between explosive strength, aerobic power and repeated sprint ability in elite basketball players.

    Science.gov (United States)

    Stojanovic, M D; Ostojic, S M; Calleja-González, J; Milosevic, Z; Mikic, M

    2012-08-01

    The aim of this study was to examine the relationship between explosive strength and aerobic power with basketball-specific repeated sprint ability in elite male basketball players. Twenty-four elite basketball players (age 22.2±3.4 years, height 197.1±6.2 cm, weight 95.7±8.8 kg; training experience 11.0±3.1 years; mean±SD), participated in the study. Subjects performed countermovement jump (CMJ) test and incremental pseudo-ramp test protocol with measured CMJ height and VO2max, respectively. Specific repeated sprint ability (RSA) test was conducted, with total sprinting time (summation of 10 sprint times - RSAtot) and sprint decrement (fatigue index - RSAFI) calculated. Significant decrements in sprint performance from the eight 30-m sprint (Pbasketball players. It seems that coaches and strength and conditioning professionals should devote additional time for explosive strength development in elite basketball players during preparatory period to enhance RSA performance.

  6. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  7. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  8. Comparing Young and Elderly Serial Reaction Time Task Performance on Repeated and Random Conditions

    Directory of Open Access Journals (Sweden)

    Fatemeh Ehsani

    2012-07-01

    Full Text Available Objectives: Acquisition motor skill training in elderly is at great importance. The main purpose of this study was to compare young and elderly performance in serial reaction time task on different repeated and random conditions. Methods & Materials: A serial reaction time task by using software was applied for studying motor learning in 30 young and 30 elderly. Each group divided randomly implicitly and explicitly into subgroups. A task 4 squares with different colors appeared on the monitor and subjects were asked to press its defined key immediately after observing it. Subjects practiced 8 motor blocks (4 repeated blocks, then 2 random blocks and 2 repeated blocks. Block time that was dependent variable measured and Independent-samples t- test with repeated ANOVA measures were used in this test. Results: young groups performed both repeated and random sequences significantly faster than elderly (P0.05. Explicit older subgroup performed 7,8 blocks slower than 6 block with a significant difference (P<0.05. Conclusion: Young adults discriminate high level performance than elderly in both repeated and random practice. Elderly performed random practice better than repeated practice.

  9. The leucine-rich repeat structure.

    Science.gov (United States)

    Bella, J; Hindle, K L; McEwan, P A; Lovell, S C

    2008-08-01

    The leucine-rich repeat is a widespread structural motif of 20-30 amino acids with a characteristic repetitive sequence pattern rich in leucines. Leucine-rich repeat domains are built from tandems of two or more repeats and form curved solenoid structures that are particularly suitable for protein-protein interactions. Thousands of protein sequences containing leucine-rich repeats have been identified by automatic annotation methods. Three-dimensional structures of leucine-rich repeat domains determined to date reveal a degree of structural variability that translates into the considerable functional versatility of this protein superfamily. As the essential structural principles become well established, the leucine-rich repeat architecture is emerging as an attractive framework for structural prediction and protein engineering. This review presents an update of the current understanding of leucine-rich repeat structure at the primary, secondary, tertiary and quaternary levels and discusses specific examples from recently determined three-dimensional structures.

  10. Repeatability and consistency of individual behaviour in juvenile and adult Eurasian harvest mice

    Science.gov (United States)

    Schuster, Andrea C.; Carl, Teresa; Foerster, Katharina

    2017-04-01

    Knowledge on animal personality has provided new insights into evolutionary biology and animal ecology, as behavioural types have been shown to affect fitness. Animal personality is characterized by repeatable and consistent between-individual behavioural differences throughout time and across different situations. Behavioural repeatability within life history stages and consistency between life history stages should be checked for the independence of sex and age, as recent data have shown that males and females in some species may differ in the repeatability of behavioural traits, as well as in their consistency. We measured the repeatability and consistency of three behavioural and one cognitive traits in juvenile and adult Eurasian harvest mice ( Micromys minutus). We found that exploration, activity and boldness were repeatable in juveniles and adults. Spatial recognition measured in a Y Maze was only repeatable in adult mice. Exploration, activity and boldness were consistent before and after maturation, as well as before and after first sexual contact. Data on spatial recognition provided little evidence for consistency. Further, we found some evidence for a litter effect on behaviours by comparing different linear mixed models. We concluded that harvest mice express animal personality traits as behaviours were repeatable across sexes and consistent across life history stages. The tested cognitive trait showed low repeatability and was less consistent across life history stages. Given the rising interest in individual variation in cognitive performance, and in its relationship to animal personality, we suggest that it is important to gather more data on the repeatability and consistency of cognitive traits.

  11. Repeatability of the Oxford Foot Model in children with foot deformity.

    Science.gov (United States)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Children's Conceptions of Bullying and Repeated Conventional Transgressions: Moral, Conventional, Structuring and Personal-Choice Reasoning

    Science.gov (United States)

    Thornberg, Robert; Thornberg, Ulrika Birberg; Alamaa, Rebecca; Daud, Noor

    2016-01-01

    This study examined 307 elementary school children's judgements and reasoning about bullying and other repeated transgressions when school rules regulating these transgressions have been removed in hypothetical school situations. As expected, children judged bullying (repeated moral transgressions) as wrong independently of rules and as more wrong…

  13. Repeatability of a 3D multi-segment foot model during anterior and lateral step down tests.

    Science.gov (United States)

    Lucareli, Paulo Roberto Garcia; Contani, Luciane Beatriz Grohs; Lima, Bruna; Rabelo, Nayra Deise dos Anjos; Ferreira, Cintia Lopes; Lima, Fernanda Pulpio Silva; Correa, João Carlos Ferrari; Politti, Fabiano

    2016-01-01

    The aim of the present study was to analyse the reproducibility of the Oxford Foot Model (OFM) when used with healthy adults during two clinical tests, i.e., the Anterior Step Down Test (SDA) and the Lateral Step Down Test (SDL). Five healthy participants (one male and four females, 10 limbs in total) with a mean age of 22.2 (19-30) years were assessed in four sessions of tests conducted at intervals of one week. Two independent examiners performed two of the sessions of each of the tests. For each session (intra-day), nine repetitions of each clinical test (SDA and SDL) were performed. After an interval of three hours, the data were collected again. The tests were conducted again after an interval of one week using the same experimental conditions. The intra- and inter-session repeatabilities of the ranges of motion of the feet were determined according to the standard error of measurement (SEM) for each examiner and for the differences between the examiners. The repeatabilities of the results were high for both of the conducted tests. The SEM results were as follows: 0.47-1.94° for the intra-examiner assessment (SDA), 0.55-2.01° for the inter-examiner comparison (SDA), 0.44-2.43° for the intra-examiner assessment (SDL), and 0.54-1.89° for the inter-examiner comparison (SDL). The OFM model was shown to be reproducible in terms of assessing the range of motion of healthy adults during functional tests (SDA and SDL). Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  15. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK

    Directory of Open Access Journals (Sweden)

    Rosa Weiss Telles

    Full Text Available Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK. Material and methods: A test–retest design including 19 adults (38 knee images was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD values. Repeatability was assessed for IMD and joint space width (JSW measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively. Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV = 54.68%; intraclass correlation coefficient (ICC (95%CI = 0.59 (0.34–0.77]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI = 0.74 (0.55–0.85–0.94 (0.87–0.97]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.

  16. Prognostic usefulness of repeated echocardiographic evaluation after acute myocardial infarction. TRACE Study Group. TRAndolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Korup, E; Køber, L; Torp-Pedersen, C

    1999-01-01

    The prognostic value of repeated echocardiographic measurement of left ventricular function after acute myocardial infarction was evaluated. We found that repeated measurements of wall motion index in survivors of acute myocardial infarction, with no reinfarction, provide important prognostic...

  17. Characteristics of intergenerational contractions of the CTG repeat in myotonic dystropy

    Energy Technology Data Exchange (ETDEWEB)

    Ashizawa, T.; Anvret, M.; Grandell, U.; Baiget, M.; Cobo, A.M.; Barcelo, J.M.; Korneluk, R.G.; Dallapiccola, B.; Novelli, G.; Fenwick, R.G. Jr. (and others)

    1994-03-01

    In myotonic dystropy (DM), the size of a CTG repeat in the DM kinase gene generally increases in successive generations with clinical evidence of anticipation. However, there have also been cases with an intergenerational contraction of the repeat. The authors have examined 1,489 DM parent-offspring pairs, of which 95 (6.4%) showed such contractions in peripheral blood leukocytes (PBL). In 56 of th 95 pairs, clinical data allowed an analysis of their anticipation status. It is surprising that anticipation occurred in 27 (48%) of these 56 pairs, while none clearly showed a later onset of DM in the asymptomatic offspring. The contraction occurred in 76 (10%) of 753 paternal transmission and in 19 (3%) of 736 maternal transmissions. Anticipation was observed more frequently in maternal (85%) than in paternal (37%) transmissions (P<.001). The parental repeat size correlated with the size of intergenerational contraction (r[sup 2] = .50, P [much lt].001), and the slope of linear regression was steeper in paternal ([minus].62) than in maternal ([minus].30) transmissions (P [much lt].001). Sixteen DM parents had multiple DM offspring with the CTG repeat contractions. This frequency was higher than the frequency expected from the probability of the repeat contractions (6.4%) and the size of DM sib population (1.54 DM offspring per DM parent, in 968 DM parents). The authors conclude that (1) intergenerational contraction of the CTG repeat in leukocyte DNA frequently accompanies apparent anticipation, especially when DM is maternally transmitted, and (2) the paternal origin of the repeat and the presence of the repeat contraction in a sibling increase the probability of the CTG repeat contraction. 43 refs., 1 fig., 4 tabs.

  18. Measuring the differences in work ratios between pediatric and adult ophthalmologic examinations.

    Science.gov (United States)

    Hyun, Joo; Chang, Jee Ho; Kim, Seung Hoon; Park, Song Hee; Kim, Sunghoon

    2017-06-01

    To assess the differences in work needed for pediatric and adult ophthalmologic examinations. Seven ophthalmology residents conducted slit-lamp and refraction examinations on children 3-7 years of age and adults 20-69 years of age. The examiners reported the magnitude estimate (ME) of their work in relation to two references (cross-reference ME): average adult examination and average pediatric examination. The examination time was also measured. For the slit-lamp examination, 50 children and 58 adults were recruited. The ME was 1.45 (95% CI, 1.30-1.62) times higher for the pediatric examinations than for the adult examinations when the reference was an average adult case. With respect to time, the pediatric examinations took 1.22 (95% CI, 1.06-1.41) times longer than the adult examinations. For the refraction examinations, 58 children and 96 adults were recruited. The ME was 1.35 (95% CI, 1.21-1.52) times higher for the pediatric examinations. The pediatric examination took 1.32 (95% CI, 1.16-1.50) times longer than the adult examination. The cross-reference ME ratios measuring the pediatric over adult examinations against both the pediatric and adult reference cases were equivalent in both the slit-lamp and the refraction examinations; however, the ME and time ratios of the pediatric over the adult examinations were not equivalent for the slit-lamp or for the refraction examinations. The cross-reference ME showed that pediatric ophthalmologic examinations require more work than the adult examination with validity and reliability. The time estimate was insufficient as a single indicator for work estimation. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    Science.gov (United States)

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies

  20. Examination of tumor diameter measurement precision by RECIST

    International Nuclear Information System (INIS)

    Goto, Masami; Ino, Kenji; Akahane, Masaaki

    2007-01-01

    Image evaluation with Response Evaluation Criteria in Solid Tumors (RECIST) evaluates the change in a measurable lesion as determined by ruler or micrometer caliper. However, there is no definition of the conditions thought to influence the precision of measurement. We therefore examined the effects on measurement precision by changing image amplification, window width (WW), window level (WL), and time phase. Moreover, to determine response rate, one-dimensional evaluation with RECIST was compared with the two-dimensional evaluation of World Health Organization (WHO) for a hepatocellular carcinoma. The results of measuring the object lesion for measured value variation were as follows. Under image conditions of 1 time expansion/WW 150/WL 100 was (4.92±1.94)%. Under image conditions of 1 time expansion/WW 350/WL 75 was (4.42±1.70)%. Under image conditions of 4 times expansion/WW 150/WL 100 was (2.52±0.82)%. Under image conditions of 4 times expansion/WW 350/WL 75 was (2.83±1.10)%. When an image was enlarged to 4 times, precision doubled. There was no a difference in comparing RECIST to WHO in terms of response rate. Thus the best method was considered to be RECIST because of its convenience. (author)

  1. Spatial Cluster Detection for Repeatedly Measured Outcomes while Accounting for Residential History

    OpenAIRE

    Cook, Andrea J.; Gold, Diane R.; Li, Yi

    2009-01-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information ...

  2. Social instigation and repeated aggressive confrontations in male Swiss mice: analysis of plasma corticosterone, CRF and BDNF levels in limbic brain areas

    Directory of Open Access Journals (Sweden)

    Paula Madeira Fortes

    2017-06-01

    Full Text Available Abstract Introduction: Agonistic behaviors help to ensure survival, provide advantage in competition, and communicate social status. The resident-intruder paradigm, an animal model based on male intraspecific confrontations, can be an ethologically relevant tool to investigate the neurobiology of aggressive behavior. Objectives: To examine behavioral and neurobiological mechanisms of aggressive behavior in male Swiss mice exposed to repeated confrontations in the resident intruder paradigm. Methods: Behavioral analysis was performed in association with measurements of plasma corticosterone of mice repeatedly exposed to a potential rival nearby, but inaccessible (social instigation, or to 10 sessions of social instigation followed by direct aggressive encounters. Moreover, corticotropin-releasing factor (CRF and brain-derived neurotrophic factor (BNDF were measured in the brain of these animals. Control mice were exposed to neither social instigation nor aggressive confrontations. Results: Mice exposed to aggressive confrontations exhibited a similar pattern of species-typical aggressive and non-aggressive behaviors on the first and the last session. Moreover, in contrast to social instigation only, repeated aggressive confrontations promoted an increase in plasma corticosterone. After 10 aggressive confrontation sessions, mice presented a non-significant trend toward reducing hippocampal levels of CRF, which inversely correlated with plasma corticosterone levels. Conversely, repeated sessions of social instigation or aggressive confrontation did not alter BDNF concentrations at the prefrontal cortex and hippocampus. Conclusion: Exposure to repeated episodes of aggressive encounters did not promote habituation over time. Additionally, CRF seems to be involved in physiological responses to social stressors.

  3. Validity and repeatability of goniometry in normal horses.

    Science.gov (United States)

    Adair, Henry S; Marcellin-Little, Denis J; Levine, David

    2016-07-19

    To assess validity and inter- and intra-tester reliability of equine goniometry and to establish values for carpal, metacarpophalangeal, tarsal, and metatarsophalangeal flexion and extension in horses. Seventeen healthy equine subjects of varied breeds were used. Three investigators blindly and independently measured in triplicate the extension and flexion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints of 17 horses after sedation. Radiographs of these joints in flexion and extension were acquired while under sedation. Goniometric and radiographic measurements were compared statistically and were correlated. A Bland-Altman plot was constructed. Inter- and intra-tester repeatability of goniometry were evaluated by calculating intraclass correlation coefficients (ICC). Mean flexion and extension of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints were calculated. Goniometric and radiographic measurements did not differ statistically and were significantly correlated (correlation coefficients ranged from 0.59 - 0.89). The mean difference between goniometric and radiographic measurements was 0.4°. Triplicate measurements collected by the three raters did not differ significantly within raters (ICC ranging from 0.950 - 0.995) and between raters (ICC ranging from 0.942 - 0.989). Goniometry is a valid and repeatable tool for evaluation of the range of motion of carpal, metacarpophalangeal, tarsal, and metatarsophalangeal joints in standing, sedated healthy horses.

  4. Mood and autonomic responses to repeated exposure to the Trier Social Stress Test for Groups (TSST-G).

    Science.gov (United States)

    Boesch, Maria; Sefidan, Sandra; Ehlert, Ulrike; Annen, Hubert; Wyss, Thomas; Steptoe, Andrew; La Marca, Roberto

    2014-05-01

    A group version of the Trier Social Stress Test (TSST-G) was introduced as a standardized, economic and efficient tool to induce a psychobiological stress response simultaneously in a group of subjects. The aim of the present study was to examine the efficacy of the TSST-G to repeatedly induce an affective and autonomic stress response while comparing two alternative protocols for the second examination. Healthy young male recruits participated twice in the TSST-G 10 weeks apart. In the first examination, the TSST-G consisted of a combination of mental arithmetic and a fake job interview (TSST-G-1st; n=294). For the second examination, mental arithmetic was combined with either (a) a defensive speech in response to a false shoplifting accusation (TSST-G-2nd-defence; n=105), or (b) a speech on a more neutral topic selected by the investigators (TSST-G-2nd-presentation; n=100). Affect ratings and salivary alpha-amylase (sAA) were determined immediately before and after the stress test, while heart rate (HR) and heart rate variability (HRV) were measured continuously. TSST-G-1st resulted in a significant increase of negative affect, HR, and sAA, and a significant decrease in positive affect and HRV. TSST-G-2nd, overall, resulted in a significant increase of HR and sAA (the latter only in response to TSST-G-2nd-defence) and a decrease in HRV, while no significant affect alterations were found. When comparing both, TSST-G-2nd-defence and -2nd-presentation, the former resulted in a stronger stress response with regard to HR and HRV. The findings reveal that the TSST-G is a useful protocol to repeatedly evoke an affective and autonomic stress response, while repetition leads to affective but not necessarily autonomic habituation. When interested in examining repeated psychosocial stress reactivity, a task that requires an ego-involving effort, such as a defensive speech, seems to be significantly superior to a task using an impersonal speech. Copyright © 2014 Elsevier

  5. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  6. The value of the repeated examination of BRAF V600E mutation status in diagnostics of papillary thyroid cancer.

    Science.gov (United States)

    Beiša, Augustas; Beiša, Virgilijus; Stoškus, Mindaugas; Ostanevičiūtė, Elvyra; Griškevičius, Laimonas; Strupas, Kęstutis

    2016-01-01

    Nodular thyroid disease is one of the most frequently diagnosed pathologies of the adult population in iodine-deficient regions. Approximately 30% of thyroid aspirates are classified as nondiagnostic/unsatisfactory or indeterminate. However, patients with indeterminate cytology still undergo surgery. The object of this study was to determine the diagnostic value of re-examining the BRAF V600E mutation in papillary thyroid carcinoma patients. All patients underwent ultrasound guided fine-needle aspiration of a thyroid nodule. They were assigned to one of the four groups (indeterminate or positive for malignant cells) of the Bethesda System for Reporting Thyroid Cytopathology. Genetic investigation of the BRAF V600E mutation was performed for all of the fine-needle aspiration cytology specimens. All of the patients underwent surgery. Subsequently, histological investigation of the removed tissues was performed. Additional analysis of the BRAF V600E mutation from the histology specimen was then performed for the initially BRAF-negative cases. Two hundred and fourteen patients were involved in the study. One hundred and six (49.53%) patients were diagnosed with thyroid cancer. Of these 106 patients, 95 (89.62%) patients were diagnosed with papillary thyroid cancer. The BRAF V600E mutation was positive in 62 (65.26%) and negative in 33 (34.74%) histologically confirmed papillary thyroid cancer cases. After the genetic investigation, a total of 74 (77.89%) papillary thyroid cancer cases were positive for the BRAF V600E mutation and 21 (22.11%) were negative. Repeated examination of the BRAF V600E mutation status in the fine-needle aspiration may potentially increase the sensitivity of papillary thyroid cancer diagnostics.

  7. Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ahmad, Sumayya; Mathews, Priya M; Lindsley, Kristina; Alkharashi, Majed; Hwang, Frank S; Ng, Sueko M; Aldave, Anthony J; Akpek, Esen Karamursel

    2016-01-01

    To compare repeat penetrating keratoplasty (PK) with Boston type I keratoprosthesis (KPro) implantation for full-thickness donor corneal graft failure. Previous donor graft failure is a common indication for both PK and KPro implantation. Selection of the surgical procedure is entirely dependent on the surgeon because there are no studies available for guidance. Therefore, a systematic review was undertaken to examine vision, device retention, graft clarity, and postoperative glaucoma and infection outcomes after repeat PK versus KPro implantation. Articles with data regarding repeat PK published between 1990 and 2014 were identified in PubMed, EMBASE, the Latin American and Caribbean Health Sciences Literature Database, and the Cochrane Central Register of Controlled Trials and were reviewed. Results were compared with a retrospective review of consecutive, nonrandomized, longitudinal case series of KPro implantations performed at 5 tertiary care centers in the United States. Visual acuity at 2 years was the primary outcome measure. The proportion of clear grafts in the repeat PK group, device retention in the KPro group, and the development of postoperative glaucoma and infection were secondary outcome measures. The search strategy identified 17 128 articles in the PK analysis. After screening, 26 studies (21 case series and 5 cohort studies) were included in the review. Pooled analysis of the 26 unique studies demonstrated a 42% (95% confidence interval [CI], 30%-56%) likelihood of maintaining 20/200 or better at 2 years after repeat PK, compared with an 80% (95% CI, 68%-88%) probability with KPro implantation. The probability of maintaining a clear graft at 5 years was 47% (95% CI, 40%-54%) after repeat PK, whereas the probability of retention of the KPro at 5 years was 75% (95% CI, 64%-84%). The rate of progression of glaucoma at 3 years was 25% (95% CI, 10%-44%) after repeat PK and 30% in the KPro cohort. These results demonstrate favorable outcomes of KPro

  8. Construction of Subgame-Perfect Mixed Strategy Equilibria in Repeated Games

    NARCIS (Netherlands)

    Berg, Kimmo; Schoenmakers, Gijsbertus

    2017-01-01

    This paper examines how to construct subgame-perfect mixed-strategy equilibria in discounted repeated games with perfect monitoring.We introduce a relatively simple class of strategy profiles that are easy to compute and may give rise to a large set of equilibrium payoffs. These sets are called

  9. Intra-rater repeatability of the Oxford foot model in healthy children in different stages of the foot roll over process during gait

    DEFF Research Database (Denmark)

    Curtis, D J; Bencke, J; Stebbins, J A

    2009-01-01

    BACKGROUND: The repeatability of the Oxford foot model has been reported, but possible variations in the repeatability during the foot roll over process have not been examined. The aim of this study was to determine the relative and absolute repeatability of the model for each stage of the foot...... roll over process during gait and to compare foot kinematic data from this study with that from another centre as a preliminary examination of the model's inter-centre repeatability and validity. METHOD: Eight healthy children were tested twice at the gait laboratory. Foot kinematics from this study...... were plotted against those from an earlier repeatability study and repeatability statistics calculated for the three rockers of stance phase and swing phase. RESULTS: Foot kinematics from this study and an earlier repeatability study produced similar kinematic patterns and joint angle ranges...

  10. Awareness in contextual cueing of visual search as measured with concurrent access- and phenomenal-consciousness tasks.

    Science.gov (United States)

    Schlagbauer, Bernhard; Müller, Hermann J; Zehetleitner, Michael; Geyer, Thomas

    2012-10-25

    In visual search, context information can serve as a cue to guide attention to the target location. When observers repeatedly encounter displays with identical target-distractor arrangements, reaction times (RTs) are faster for repeated relative to nonrepeated displays, the latter containing novel configurations. This effect has been termed "contextual cueing." The present study asked whether information about the target location in repeated displays is "explicit" (or "conscious") in nature. To examine this issue, observers performed a test session (after an initial training phase in which RTs to repeated and nonrepeated displays were measured) in which the search stimuli were presented briefly and terminated by visual masks; following this, observers had to make a target localization response (with accuracy as the dependent measure) and indicate their visual experience and confidence associated with the localization response. The data were examined at the level of individual displays, i.e., in terms of whether or not a repeated display actually produced contextual cueing. The results were that (a) contextual cueing was driven by only a very small number of about four actually learned configurations; (b) localization accuracy was increased for learned relative to nonrepeated displays; and (c) both consciousness measures were enhanced for learned compared to nonrepeated displays. It is concluded that contextual cueing is driven by only a few repeated displays and the ability to locate the target in these displays is associated with increased visual experience.

  11. 78 FR 65594 - Vehicular Repeaters

    Science.gov (United States)

    2013-11-01

    ... coordinators estimate the effect on coordination fees? Does the supposed benefit that mobile repeater stations... allow the licensing and operation of vehicular repeater systems and other mobile repeaters by public... email: [email protected] or phone: 202-418- 0530 or TTY: 202-418-0432. For detailed instructions for...

  12. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  13. Tests and measures used by specialist physical therapists when examining patients with stroke.

    Science.gov (United States)

    Andrews, A Williams; Folger, Stephen E; Norbet, Shannon E; Swift, Lindsay C

    2008-09-01

    Examination procedures preferred by physical therapists have not been documented either specifically or comprehensively. The purpose of this study was to determine which tests and measures are used most frequently by specialists in the examination of adults with stroke. Physical therapy specialists were identified as having geriatric or neurologic certification through the American Board of Physical Therapy Specialties. A request to participate in a Web-based survey was sent to 471 individuals in the American Physical Therapy Association's Directory of Certified Specialists. A comprehensive list of tests and measures was first derived from the Interactive Guide to Physical Therapist Practice. The list was finalized based on several exclusion criteria and the results of a pilot study. Subjects rated the frequency of use of 294 tests and measures with patients post-stroke on a Likert scale. The survey response rate was 31.7% (n = 128). The 50 most frequently used tests and measures were identified. The results of this study do not identify the tests and measures that clinicians should use, only those that the specialists use. Nevertheless, clinicians may want to consider tests and measurements frequently used by specialists when examining adults with stroke.

  14. Repeat Customer Success in Extension

    Science.gov (United States)

    Bess, Melissa M.; Traub, Sarah M.

    2013-01-01

    Four multi-session research-based programs were offered by two Extension specialist in one rural Missouri county. Eleven participants who came to multiple Extension programs could be called "repeat customers." Based on the total number of participants for all four programs, 25% could be deemed as repeat customers. Repeat customers had…

  15. Film repeats in radiology department

    International Nuclear Information System (INIS)

    Suwan, A. Z.; Al-Shakharah, A. I

    1997-01-01

    During a one year period, 4910 radiographs of 55780 films were repeated. The objective of our study was to analyse and to classify the causes in order to minimize the repeats, cut the expenses and to provide optimal radiographs for accurate diagnosis. Analysis of the different factors revealed that, 43.6% of film repeats in our service were due to faults in exposure factors, centering comprises 15.9% of the repeats, while too much collimation was responsible for 7.6% of these repeats. All of which can be decreased by awareness and programmed training of technicians. Film blurring caused by patient motion was also responsible for 4.9% for radiographs reexamination, which can be minimized by detailed explanation to the patient and providing the necessary privacy. Fogging of X-Ray films by improper storage or inadequate handling or processing faults were responsible for 14.5% in repeats in our study. Methods and criteria for proper storage and handling of films were discussed. Recommendation for using modern day-light and laser processor has been high lighted. Artefacts are noticeably high in our cases, due to spinal dresses and frequent usage of precious metals for c osmotic purposes in this part of the world. The repeated films comprise 8.8% of all films We conclude that, the main factor responsible for repeats of up to 81.6% of cases was the technologists, thus emphasizing the importance of adequate training of the technologists. (authors). 15 refs., 9 figs., 1 table

  16. Examination of offsite radiological emergency measures for nuclear reactor accidents involving core melt

    International Nuclear Information System (INIS)

    Aldrich, D.C.; McGrath, P.E.; Rasmussen, N.C.

    1978-06-01

    Evacuation, sheltering followed by population relocation, and iodine prophylaxis are evaluated as offsite public protective measures in response to nuclear reactor accidents involving core-melt. Evaluations were conducted using a modified version of the Reactor Safety Study consequence model. Models representing each measure were developed and are discussed. Potential PWR core-melt radioactive material releases are separated into two categories, ''Melt-through'' and ''Atmospheric,'' based upon the mode of containment failure. Protective measures are examined and compared for each category in terms of projected doses to the whole body and thyroid. Measures for ''Atmospheric'' accidents are also examined in terms of their influence on the occurrence of public health effects

  17. Synthetic food coloring and behavior: a dose response effect in a double-blind, placebo-controlled, repeated-measures study.

    Science.gov (United States)

    Rowe, K S; Rowe, K J

    1994-11-01

    To establish whether there is an association between the ingestion of synthetic food colorings and behavioral change in children referred for assessment of "hyperactivity." From approximately 800 children referred to the Royal Children's Hospital (Melbourne) for assessment of suspected hyperactivity, 200 were included in a 6-week open trial of a diet free of synthetic food coloring. The parents of 150 children reported behavioral improvement with the diet, and deterioration on the introduction of foods noted to contain synthetic coloring. A 30-item behavioral rating inventory was devised from an examination of the clinical histories of 50 suspected reactors. Thirty-four other children (23 suspected reactors, 11 uncertain reactors) and 20 control subjects, aged 2 to 14 years, were studied. A 21-day, double-blind, placebo-controlled, repeated-measures study used each child as his or her own control. Placebo, or one of six dose levels of tartrazine (1, 2, 5, 10, 20, 50 mg), was administered randomly each morning, and behavioral ratings were recorded by parents at the end of each 24 hours. The study identified 24 children as clear reactors (19 of 23 "suspected reactors," 3 of 11 "uncertain reactors," and 2 of 20 "control subjects"). They were irritable and restless and had sleep disturbance. Significant reactions were observed at all six dose levels. A dose response effect was obtained. With a dose increase greater than 10 mg, the duration of effect was prolonged. Behavioral changes in irritability, restlessness, and sleep disturbance are associated with the ingestion of tartrazine in some children. A dose response effect was observed.

  18. Repeated nicotine exposure enhances reward-related learning in the rat.

    Science.gov (United States)

    Olausson, Peter; Jentsch, J David; Taylor, Jane R

    2003-07-01

    Repeated exposure to addictive drugs causes neuroadaptive changes in cortico-limbic-striatal circuits that may underlie alterations in incentive-motivational processes and reward-related learning. Such drug-induced alterations may be relevant to drug addiction because enhanced incentive motivation and increased control over behavior by drug-associated stimuli may contribute to aspects of compulsive drug-seeking and drug-taking behaviors. This study investigated the consequences of repeated nicotine treatment on the acquisition and performance of Pavlovian discriminative approach behavior, a measure of reward-related learning, in male rats. Water-restricted rats were trained to associate a compound conditioned stimulus (tone+light) with the availability of water (the unconditioned stimulus) in 15 consecutive daily sessions. In separate experiments, rats were repeatedly treated with nicotine (0.35 mg/kg, s.c.) either (1) prior to the onset of training, (2) after each daily training session was completed (ie postsession injections), or (3) received nicotine both before the onset of training as well as after each daily training session. In this study, all nicotine treatment schedules increased Pavlovian discriminative approach behavior and, thus, prior repeated exposure to nicotine, repeated postsession nicotine injections, or both, facilitated reward-related learning.

  19. Repeat migration and disappointment.

    Science.gov (United States)

    Grant, E K; Vanderkamp, J

    1986-01-01

    This article investigates the determinants of repeat migration among the 44 regions of Canada, using information from a large micro-database which spans the period 1968 to 1971. The explanation of repeat migration probabilities is a difficult task, and this attempt is only partly successful. May of the explanatory variables are not significant, and the overall explanatory power of the equations is not high. In the area of personal characteristics, the variables related to age, sex, and marital status are generally significant and with expected signs. The distance variable has a strongly positive effect on onward move probabilities. Variables related to prior migration experience have an important impact that differs between return and onward probabilities. In particular, the occurrence of prior moves has a striking effect on the probability of onward migration. The variable representing disappointment, or relative success of the initial move, plays a significant role in explaining repeat migration probabilities. The disappointment variable represents the ratio of actural versus expected wage income in the year after the initial move, and its effect on both repeat migration probabilities is always negative and almost always highly significant. The repeat probabilities diminish after a year's stay in the destination region, but disappointment in the most recent year still has a bearing on the delayed repeat probabilities. While the quantitative impact of the disappointment variable is not large, it is difficult to draw comparisons since similar estimates are not available elsewhere.

  20. Quantum repeated games revisited

    International Nuclear Information System (INIS)

    Frąckiewicz, Piotr

    2012-01-01

    We present a scheme for playing quantum repeated 2 × 2 games based on Marinatto and Weber’s approach to quantum games. As a potential application, we study the twice repeated Prisoner’s Dilemma game. We show that results not available in the classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games proposed by Iqbal and Toor. We point out the drawbacks that make their results unacceptable. (paper)

  1. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study.

    Science.gov (United States)

    Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S; Cohen, Allison; Coull, Brent A; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A; Li, Yongsheng; Stone, Peter H; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R

    2014-03-01

    Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Baseline BAD was negatively associated with particle pollution, including home/trip-integrated BC (-0.02 mm; 95% CI: -0.04, -0.003, for a 0.28 μg/m3 increase in BC), OC (-0.08 mm; 95% CI: -0.14, -0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Zanobetti A, Luttmann

  2. Test-retest repeatability of strength capacity, aerobic power and pericranial tenderness of neck and shoulder muscles in children - relevant for tension-type headache

    Directory of Open Access Journals (Sweden)

    Tornøe B

    2013-08-01

    Full Text Available Birte Tornøe,1,2,5,6 Lars L Andersen,3 Jørgen H Skotte,3 Rigmor Jensen,4 Gunvor Gard,1 Liselotte Skov,2 Inger Hallström1 1Department of Health Sciences, Lund University, Scania, Sweden; 2Children's Headache Clinic, Department of Pediatrics, University of Copenhagen, Herlev Hospital, Herlev, Denmark; 3National Research Centre for the Working Environment, Copenhagen, Denmark; 4Danish Headache Center, Department of Neurology, University of Copenhagen, Glostrup Hospital, Glostrup, Denmark; 5Department of Physiotherapy and Occupational Therapy, University of Copenhagen, Glostrup Hospital, Glostrup, Denmark; 6Department of Physiotherapy, Medical Department, University of Copenhagen, Herlev Hospital, Herlev, Denmark Background: Frequent or chronic tension-type headache in children is a prevalent and debilitating condition for the child, often leading to medication overuse. To explore the relationship between physical factors and tension-type headache in children, the quality of repeated measures was examined. The aim of the present study was to determine the test-retest repeatability of parameters determining isometric neck and shoulder strength and stability, aerobic power, and pericranial tenderness in children. Methods: Twenty-five healthy children, 9 to 18 years of age, participated in test-retest procedures within a 1-week interval. A computerized padded force transducer was used for testing. The tests included the isometric maximal voluntary contraction and force steadiness of neck flexion and extension, and the isometric maximal voluntary contraction and rate of force of the dominant shoulder. Pericranial tenderness was recorded by means of standardized manual palpation, and a submaximal cycle ergometer test predicted maximal oxygen uptake (VO2 max. The measurements were evaluated in steps, using the intraclass correlation coefficient (ICC; changes in the mean between the two test occasions; the levels of agreement, visualized in Bland

  3. Repeatability and accuracy of reproductive tract scoring to determine pubertal status in beef heifers.

    Science.gov (United States)

    Rosenkrans, Kelly S; Hardin, David K

    2003-03-01

    The objective of this study was to compare the repeatability and accuracy of palpation per rectum to transrectal ultrasonography and serum progesterone concentrations for determining pubertal status in beef heifers. One hundred and seventy-four rectal examinations were performed on 29 predominantly Angus heifers by two veterinarians (A and B) and assigned individual reproductive tract scores (RTS) during monthly examinations over a 3-month period. Heifers were examined in the morning by both veterinarians, randomized, and re-examined in the afternoon. The size and location of ovarian structures of each heifer were determined by ultrasonography. Heifers with follicles >10mm in diameter or corpora lutea were classified as pubertal. Serum progesterone concentrations at the time of the examination and 10 days later were determined by radioimmunoassay and used to classify heifers as prepubertal (or=1 ng/ml). Kappa, which describes degree of agreement beyond chance, was used to determine repeatability of the RTS system. Multicategory Kappa for agreement was 0.64 within veterinarian, 0.46 between veterinarian, and 0.35 between palpation per rectum and transrectal ultrasonography. Sensitivity and specificity of palpation per rectum for diagnosis of pubertal status compared to serum progesterone levels were higher (82 and 69%, respectively) than sensitivity and specificity of ultrasonography (79 and 59%, respectively). This study validates the RTS system as a repeatable and accurate screening test to evaluate pubertal status in groups of heifers prior to the onset of the breeding season.

  4. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    Science.gov (United States)

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  5. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    Science.gov (United States)

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  6. Effect of hip braces on brake response time: Repeated measures designed study.

    Science.gov (United States)

    Dammerer, Dietmar; Waidmann, Cornelia; Huber, Dennis G; Krismer, Martin; Haid, Christian; Liebensteiner, Michael C

    2017-08-01

    The question whether or not a patient with a hip brace should drive a car is of obvious importance because the advice given to patients to resume driving is often anecdotal as few scientific data are available on this specific subject. To assess driving ability (brake response time) with commonly used hip braces. Repeated measures design. Brake response time was assessed under six conditions: (1) without a brace (control), (2) with a typical postoperative hip brace with adjustable range of motion and the settings: unrestricted, (3) flexion limited to 70°, (4) extension blocked at 20° hip flexion, (5) both flexion and extension limited (20°/70°) and (6) an elastic hip bandage. Brake response time was assessed using a custom-made driving simulator as used in previous studies. The participants were a convenience sample of able-bodied participants. A total of 70 participants (35 women and 35 men) participated in our study. Mean age was 31.1 (standard deviation: 10.6; range: 21.7-66.4) years. A significant within-subject effect for brake response time was found ( p = 0.009), but subsequent post hoc analyses revealed no significant differences between control and the other settings. Based on our findings, it does not seem mandatory to recommend driving abstinence for patients wearing a hip orthosis. We suggest that our results be interpreted with caution, because (1) an underlying pathological hip condition needs to be considered, (2) the ability to drive a car safely is multifactorial and brake response time is only one component thereof and (3) brake response time measurements were performed only with healthy participants. Clinical relevance Hip braces are used in the context of joint-preserving and prosthetic surgery of the hip. Therefore, clinicians are confronted with the question whether to allow driving a car with the respective hip brace or not. Our data suggest that hip braces do not impair brake response time.

  7. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  8. No impact of repeated extinction exposures on operant responding maintained by different reinforcer rates.

    Science.gov (United States)

    Bai, John Y H; Podlesnik, Christopher A

    2017-05-01

    Greater rates of intermittent reinforcement in the presence of discriminative stimuli generally produce greater resistance to extinction, consistent with predictions of behavioral momentum theory. Other studies reveal more rapid extinction with higher rates of reinforcers - the partial reinforcement extinction effect. Further, repeated extinction often produces more rapid decreases in operant responding due to learning a discrimination between training and extinction contingencies. The present study examined extinction repeatedly with training with different rates of intermittent reinforcement in a multiple schedule. We assessed whether repeated extinction would reverse the pattern of greater resistance to extinction with greater reinforcer rates. Counter to this prediction, resistance to extinction was consistently greater across twelve assessments of training followed by six successive sessions of extinction. Moreover, patterns of responding during extinction resembled those observed during satiation tests, which should not alter discrimination processes with repeated testing. These findings join others suggesting operant responding in extinction can be durable across repeated tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Genetic Contributors to Intergenerational CAG Repeat Instability in Huntington's Disease Knock-In Mice.

    Science.gov (United States)

    Neto, João Luís; Lee, Jong-Min; Afridi, Ali; Gillis, Tammy; Guide, Jolene R; Dempsey, Stephani; Lager, Brenda; Alonso, Isabel; Wheeler, Vanessa C; Pinto, Ricardo Mouro

    2017-02-01

    Huntington's disease (HD) is a neurodegenerative disorder caused by the expansion of a CAG trinucleotide repeat in exon 1 of the HTT gene. Longer repeat sizes are associated with increased disease penetrance and earlier ages of onset. Intergenerationally unstable transmissions are common in HD families, partly underlying the genetic anticipation seen in this disorder. HD CAG knock-in mouse models also exhibit a propensity for intergenerational repeat size changes. In this work, we examine intergenerational instability of the CAG repeat in over 20,000 transmissions in the largest HD knock-in mouse model breeding datasets reported to date. We confirmed previous observations that parental sex drives the relative ratio of expansions and contractions. The large datasets further allowed us to distinguish effects of paternal CAG repeat length on the magnitude and frequency of expansions and contractions, as well as the identification of large repeat size jumps in the knock-in models. Distinct degrees of intergenerational instability were observed between knock-in mice of six background strains, indicating the occurrence of trans-acting genetic modifiers. We also found that lines harboring a neomycin resistance cassette upstream of Htt showed reduced expansion frequency, indicative of a contributing role for sequences in cis, with the expanded repeat as modifiers of intergenerational instability. These results provide a basis for further understanding of the mechanisms underlying intergenerational repeat instability. Copyright © 2017 by the Genetics Society of America.

  10. Repeated Recall and PKM? Maintain Fear Memories in Juvenile Rats

    Science.gov (United States)

    Oliver, Chicora F.; Kabitzke, Patricia; Serrano, Peter; Egan, Laura J.; Barr, Gordon A.; Shair, Harry N.; Wiedenmayer, Christoph

    2016-01-01

    We examined the neural substrates of fear memory formation and maintenance when repeated recall was used to prevent forgetting in young animals. In contrast to adult rats, juveniles failed to show contextual fear responses at 4 d post-fear conditioning. Reconsolidation sessions 3 and 6 d after conditioning restored contextual fear responses in…

  11. Is energy imparted a good measure of the radiation risk associated with CT examinations

    International Nuclear Information System (INIS)

    Huda, W.

    1984-01-01

    The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the risk per unit energy imparted can significantly underestimate the radiation risk. (author)

  12. Studies on Section XI ultrasonic repeatability

    International Nuclear Information System (INIS)

    Jamison, T.D.; McDearman, W.R.

    1981-05-01

    A block representative of a nuclear component has been welded containing intentional defects. Acoustic emission data taken during the welding correlate well with ultrasonic data. Repetitive ultrasonic examinations have been performed by skilled operators using a procedure based on that desribed in ASME Section XI. These examinations were performed by different examination teams using different ultrasonic equipment in such a manner that the effects on the repeatability of the ultrasonic test method caused by the operator and by the use of different equipment could be estimated. It was tentatively concluded that when considering a large number of inspections: (1) there is no significant difference in indication sizing between operators, and (2) there is a significant difference in amplitude and defect sizing when instruments having different, Code acceptable operating characteristics are used. It was determined that the Section XI sizing parameters follow a bivariate normal distribution. Data derived from ultrasonically and physically sizing indications in nuclear components during farication show that the Section XI technique tends to overestimate the size of the reflectors

  13. Anesthetic efficacy of a repeated intraosseous injection given 30 min following an inferior alveolar nerve block/intraosseous injection.

    OpenAIRE

    Reitz, J.; Reader, A.; Nist, R.; Beck, M.; Meyers, W. J.

    1998-01-01

    To determine whether a repeated intraosseous (IO) injection would increase or prolong pulpal anesthesia, we measured the degree of anesthesia obtained by a repeated IO injection given 30 min following a combination inferior alveolar nerve block/intraosseous injection (IAN/IO) in mandibular second premolars and in first and second molars. Using a repeated-measures design, we randomly assigned 38 subjects to receive two combinations of injections at two separate appointments. The combinations w...

  14. Somatic mosaicism of androgen receptor CAG repeats in colorectal carcinoma epithelial cells from men.

    Science.gov (United States)

    Di Fabio, Francesco; Alvarado, Carlos; Gologan, Adrian; Youssef, Emad; Voda, Linda; Mitmaker, Elliot; Beitel, Lenore K; Gordon, Philip H; Trifiro, Mark

    2009-06-01

    The X-linked human androgen receptor gene (AR) contains an exonic polymorphic trinucleotide CAG. The length of this encoded CAG tract inversely affects AR transcriptional activity. Colorectal carcinoma is known to express the androgen receptor, but data on somatic CAG repeat lengths variations in malignant and normal epithelial cells are still sporadic. Using laser capture microdissection (LCM), epithelial cells from colorectal carcinoma and normal-appearing mucosa were collected from the fresh tissue of eight consecutive male patients undergoing surgery (mean age, 70 y; range, 54-82). DNA isolated from each LCM sample underwent subsequent PCR and DNA sequencing to precisely determine AR CAG repeat lengths and the presence of microsatellite instability (MSI). Different AR CAG repeat lengths were observed in colorectal carcinoma (ranging from 0 to 36 CAG repeats), mainly in the form of multiple shorter repeat lengths. This genetic heterogeneity (somatic mosaicism) was also found in normal-appearing colorectal mucosa. Half of the carcinoma cases examined tended to have a higher number of AR CAG repeat lengths with a wider range of repeat size variation compared to normal mucosa. MSI carcinomas tended to have longer median AR CAG repeat lengths (n = 17) compared to microsatellite stable carcinomas (n = 14), although the difference was not significant (P = 0.31, Mann-Whitney test). Multiple unique somatic mutations of the AR CAG repeats occur in colorectal mucosa and in carcinoma, predominantly resulting in shorter alleles. Colorectal epithelial cells carrying AR alleles with shorter CAG repeat lengths may be more androgen-sensitive and therefore have a growth advantage.

  15. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    Science.gov (United States)

    Surgenor, Paul Wg; Freeman, Joan; O'Connor, Cindy

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client's suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook. A quasi-experimental, pre-test post-test repeated measures design was employed. A questionnaire assessing self-esteem, depression, and positive and negative suicidal ideation was administered to the same participants pre- and post- therapy facilitating paired responses. Multiple analysis of variance and paired-samples t-tests were conducted to establish whether therapy using the PH-SIM had a significant effect on the clients' negative and positive outlook. Analyses revealed a statistically significant effect of therapy for depression, negative suicidal ideation, self-esteem, and positive suicidal ideation. Negative outlook was significantly lower after therapy and positive outlook significantly higher. The decreased negative outlook and increased positive outlook following therapy provide some support for the proposed model in fulfilling its role, though additional research is required to establish the precise role of the intervention model in achieving this.

  16. PTSD and DNA Methylation in Select Immune Function Gene Promoter Regions: A Repeated Measures Case-control Study of U.S. Military Service Members

    Science.gov (United States)

    2013-06-24

    other relevant exposures which may influ- ence DNA methylation , such as dietary factors ( folate , vitamin B12 intake) (Fenech, 2001; Piyathilake and...ARTICLE published: 24 June 2013 doi: 10.3389/fpsyt.2013.00056 PTSD and DNA methylation in select immune function gene promoter regions: a repeated measures...largely unknown. Dis- tinct expression signatures for PTSD have been found, in particular for immune activation transcripts. DNA methylation may be

  17. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  18. Beverage Intake Assessment Questionnaire: Relative Validity and Repeatability in a Spanish Population with Metabolic Syndrome from the PREDIMED-PLUS Study

    Science.gov (United States)

    Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi

    2016-01-01

    We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318

  19. Gender, obesity and repeated elevation of C-reactive protein: data from the CARDIA cohort.

    Directory of Open Access Journals (Sweden)

    Shinya Ishii

    Full Text Available C-reactive Protein (CRP measurements above 10 mg/L have been conventionally treated as acute inflammation and excluded from epidemiologic studies of chronic inflammation. However, recent evidence suggest that such CRP elevations can be seen even with chronic inflammation. The authors assessed 3,300 participants in The Coronary Artery Risk Development in Young Adults study, who had two or more CRP measurements between 1992/3 and 2005/6 to a investigate characteristics associated with repeated CRP elevation above 10 mg/L; b identify subgroups at high risk of repeated elevation; and c investigate the effect of different CRP thresholds on the probability of an elevation being one-time rather than repeated. 225 participants (6.8% had one-time and 103 (3.1% had repeated CRP elevation above 10 mg/L. Repeated elevation was associated with obesity, female gender, low income, and sex hormone use. The probability of an elevation above 10 mg/L being one-time rather than repeated was lowest (51% in women with body mass index above 31 kg/m(2, compared to 82% in others. These findings suggest that CRP elevations above 10 mg/L in obese women are likely to be from chronic rather than acute inflammation, and that CRP thresholds above 10 mg/L may be warranted to distinguish acute from chronic inflammation in obese women.

  20. Fostering repeat donations in Ghana.

    Science.gov (United States)

    Owusu-Ofori, S; Asenso-Mensah, K; Boateng, P; Sarkodie, F; Allain, J-P

    2010-01-01

    Most African countries are challenged in recruiting and retaining voluntary blood donors by cost and other complexities and in establishing and implementing national blood policies. The availability of replacement donors who are a cheaper source of blood has not enhanced repeat voluntary donor initiatives. An overview of activities for recruiting and retaining voluntary blood donors was carried out. Donor records from mobile sessions were reviewed from 2002 to 2008. A total of 71,701 blood donations; 45,515 (63.5%) being voluntary donations with 11,680 (25%) repeat donations were collected during the study period. Donations from schools and colleges contributed a steady 60% of total voluntary whilst radio station blood drives increased contribution from 10 to 27%. Though Muslim population is less than 20%, blood collection was above the 30-donation cost-effectiveness threshold with a repeat donation trend reaching 60%. In contrast Christian worshippers provided donations. Repeat donation trends amongst school donors and radio blood drives were 20% and 70% respectively. Repeat donations rates have been variable amongst different blood donor groups in Kumasi, Ghana. The impact of community leaders in propagating altruism cannot be overemphasized. Programs aiming at motivating replacement donors to be repeat donors should be developed and assessed. Copyright 2009 The International Association for Biologicals. All rights reserved.

  1. Comparing Destination Image and Loyalty between First-time and Repeat-visit Tourists

    Directory of Open Access Journals (Sweden)

    Mohamad M.

    2014-01-01

    Full Text Available The objective of this study was to investigate the difference between destination image and loyalty among first-time and repeat-visit tourists. The study was undertaken to examine aspects of underlying factors of destination image that influenced tourists’ willingness to recommend Malaysia to their friends and relatives as well as spread positive word-of-mouth to others. In addition, it was to ascertain the relationship between destination image and loyalty among first-time and repeat-visit tourists. The data was collected at Kuala Lumpur International Airport at the departure hall using self-administered questionnaires. 248 usable questionnaires were returned and analysed. The findings of the study revealed that both groups of tourists perceived Malaysia as providing a nature-based destination. The study also empirically proved that both first-time and repeat-visit tourists were willing to disseminate positive word-of-mouth and recommend Malaysia to their friends and relatives as a vacation destination to visit. However, there was a significant difference in destination loyalty between first-visit and repeat-visit tourists.

  2. Unstable systems and repeated measurements. II

    International Nuclear Information System (INIS)

    Exner, P.

    1977-01-01

    Two examples are treated. In the first, the chamber structure is only assumed to be periodic and P(t) is an exponential. In the second example no specific assumption is made about the primary decay law and the measuring device is structured as an idealized spark chamber. This example contains the results by Beskow and Nilsson as a special case. (author)

  3. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  4. The repeatability of interleukin-6, tumor necrosis factor-α, and C-reactive protein in COPD patients over one year

    Directory of Open Access Journals (Sweden)

    Umme Kolsum

    2009-04-01

    Full Text Available Umme Kolsum, Kay Roy, Cerys Starkey, Zoë Borrill, Nick Truman, Jørgen Vestbo, Dave SinghNorth West Lung Research Centre, University of Manchester, South Manchester University Hospitals Trust, Wythenshawe, Manchester, UKBackground: Many of the systemic manifestations of chronic obstructive pulmonary disease (COPD are mediated through increased systemic levels of inflammatory proteins. We assessed the long term repeatability of Interleukin-6 (IL-6, tumor necrosis factor-α (TNF-α, and C-reactive protein (CRP over one year and examined the relationships between these systemic markers in COPD.Methods: Fifty-eight stable COPD patients completed a baseline and one-year visit. Serum IL-6, plasma CRP, and plasma TNF-α were measured. Repeatability was expressed by intraclass correlation coefficient (Ri and the Bland–Altman method. Pearson correlations were used to determine the relationships between the systemic markers at both visits.Results: There was moderate repeatability with a very high degree of statistical significance (p ≤ 0.001 between the two visits for all the systemic biomarkers (IL-6, CRP, and TNF-α. CRP was significantly associated with IL-6 at both visits (r = 0.55, p = 0.0001, r = 0.51, p = 0.0002, respectively. There were no other significant associations between the systemic markers at either of the visits.Conclusions: Systemic inflammatory biomarkers IL-6, CRP, and TNF-α were moderately repeatable over a twelve month period in COPD patients. We have also shown that a robust and repeatable association between IL-6 and CRP exists.Keywords: interleukin-6, tumor necrosis factor-α, C-reactive protein, repeatability, COPD   

  5. Repeatability and variation of region-of-interest methods using quantitative diffusion tensor MR imaging of the brain

    International Nuclear Information System (INIS)

    Hakulinen, Ullamari; Brander, Antti; Ryymin, Pertti; Öhman, Juha; Soimakallio, Seppo; Helminen, Mika; Dastidar, Prasun; Eskola, Hannu

    2012-01-01

    Diffusion tensor imaging (DTI) is increasingly used in various diseases as a clinical tool for assessing the integrity of the brain’s white matter. Reduced fractional anisotropy (FA) and an increased apparent diffusion coefficient (ADC) are nonspecific findings in most pathological processes affecting the brain’s parenchyma. At present, there is no gold standard for validating diffusion measures, which are dependent on the scanning protocols, methods of the softwares and observers. Therefore, the normal variation and repeatability effects on commonly-derived measures should be carefully examined. Thirty healthy volunteers (mean age 37.8 years, SD 11.4) underwent DTI of the brain with 3T MRI. Region-of-interest (ROI) -based measurements were calculated at eleven anatomical locations in the pyramidal tracts, corpus callosum and frontobasal area. Two ROI-based methods, the circular method (CM) and the freehand method (FM), were compared. Both methods were also compared by performing measurements on a DTI phantom. The intra- and inter-observer variability (coefficient of variation, or CV%) and repeatability (intra-class correlation coefficient, or ICC) were assessed for FA and ADC values obtained using both ROI methods. The mean FA values for all of the regions were 0.663 with the CM and 0.621 with the FM. For both methods, the FA was highest in the splenium of the corpus callosum. The mean ADC value was 0.727 ×10 -3 mm 2 /s with the CM and 0.747 ×10 -3 mm 2 /s with the FM, and both methods found the ADC to be lowest in the corona radiata. The CV percentages of the derived measures were < 13% with the CM and < 10% with the FM. In most of the regions, the ICCs were excellent or moderate for both methods. With the CM, the highest ICC for FA was in the posterior limb of the internal capsule (0.90), and with the FM, it was in the corona radiata (0.86). For ADC, the highest ICC was found in the genu of the corpus callosum (0.93) with the CM and in the uncinate

  6. Topological characteristics of helical repeat proteins

    NARCIS (Netherlands)

    Groves, M R; Barford, D

    The recent elucidation of protein structures based upon repeating amino acid motifs, including the armadillo motif, the HEAT motif and tetratricopeptide repeats, reveals that they belong to the class of helical repeat proteins. These proteins share the common property of being assembled from tandem

  7. Repeatability and Reproducibility in Proteomic Identifications by Liquid Chromatography—Tandem Mass Spectrometry

    Science.gov (United States)

    Tabb, David L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Variyath, Asokan Mulayath; Ham, Amy-Joan L.; Bunk, David M.; Kilpatrick, Lisa E.; Billheimer, Dean D.; Blackman, Ronald K.; Cardasis, Helene L.; Carr, Steven A.; Clauser, Karl R.; Jaffe, Jacob D.; Kowalski, Kevin A.; Neubert, Thomas A.; Regnier, Fred E.; Schilling, Birgit; Tegeler, Tony J.; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fisher, Susan J.; Gibson, Bradford W.; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Stein, Steven E.; Tempst, Paul; Paulovich, Amanda G.; Liebler, Daniel C.; Spiegelman, Cliff

    2009-01-01

    The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35–60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind

  8. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. The properties and interrelationships of various force-time parameters during maximal repeated rhythmic grip.

    Science.gov (United States)

    Nakada, Masakatsu; Demura, Shinichi; Yamaji, Shunsuke

    2007-01-01

    The purpose of this study was to examine the properties and interrelationships of various force-time parameters including the inflection point for the rate of decline in force during a maximal repeated rhythmic grip. Fifteen healthy males (age M=21.5, SD=2.1 yr, height M=172.4, SD=5.7 cm, body mass M=68.2, SD=9.2 kg) participated in this study. Subjects performed a maximal repeated rhythmic grip with maximal effort with a target frequency of 30 grip.min(-1) for 6 min. The force value decreased linearly and markedly until about 70% of maximal strength for about 55 s after the onset of a maximal repeated rhythmic grip, and then decreased moderately. Because all parameters showed fair or good correlations between 3 min and 6 min, they are considered to be able to sufficiently evaluate muscle endurance for 3 min instead of 6 min. However, there were significant differences between 3 min and 6 min in the integrated area, the final force, the rate of the decrement constant (k) fitting the force decreasing data to y=ae(-kx)+b and the force of maximal difference between the force and a straight line from peak force to the final force. Their parameters may vary generally by the length of a steady state, namely, a measurement time. The final force value before finishing and the rate of the decrement constant (k) reflect the latter phase during a maximal repeated rhythmic grip. Although many parameters show relatively high mutual relationships, the rate constant (k) shows relatively low correlations with other parameters. We inferred that decreasing the time until 80% of maximal strength and the amount of the decrement force for the first 1 min reflect a linear decrease in the initial phase.

  10. Measurement of dose received in knee joint x-ray examination

    International Nuclear Information System (INIS)

    Abashar, Basamat Musa Hajo

    2014-11-01

    Diagnostic x-rays examinations play an important role in the health care of the population. These examinations may involve significant irradiation of the patient and probably represent the largest man-made source of radiation exposure for the population. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study performed to assess the effective dose (ED) received in knee joint radiographic examination and to analyze dose (ed) received in knee joint radiographic examination and to analyze effective dose distribution among radiological departments under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded age, weight, height, body mass ines (BMI) derived from weight (Kg) and (Height (M)) and (height (m)) and exposure factors. The dose was measured for knee joint x-rays examination. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for knee joint Ap and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were then calculated from energy imparted using ED conversion factors proposed by IAEA. The results of ED values calculated showed that patient exposure were within the normal range of exposure. The mean ED values calculated were( 2.49 + 0.03) and (5.60 + 0.22) milli Grey for knee joint AP and lateral examinations, respectively, Further studies are recommended with more number of patients and using more two modalities for comparison.(Author)

  11. An examination of practice during radiography of the clavicle

    International Nuclear Information System (INIS)

    McEntee, Mark F.; Kinsella, Catherine

    2010-01-01

    Background: Variation in techniques is a well reported phenomenon in Radiography that can lead to dose discrepancies. Radiography of the clavicle is an examination which can result in a scattered extra-focal radiation dose to the radiosensitive organs of the thyroid, breast and eyes. Techniques for imaging the clavicle are examined and causal factors of repeats examined. Given the recent increase of the tissue weighting factor of breast tissue, an increased importance is placed upon dose reduction techniques to this area. Aims: This study aims to investigate the variation in techniques used in imaging of the clavicle and to investigate whether AP or PA position resulted in a higher level of repeat imaging. Method: To investigate current practice amongst hospitals a sample of large teaching hospitals was chosen (n = 5). An interview with radiographers was carried out along with an examination of the stated protocols in each of these hospital plus retrospective analysis of the images produced in each of these hospitals. Results: Variations in practice were established, significant differences in collimation and vertical centring were found. AP coned view of the clavicle was performed by 80% of radiographers interviewed with 20% of radiographers performing an AP shoulder. This variation being 100% correlated with country of training. 60% of radiographers were found to perform AP15 o cranial angulation clavicle as a second projection with 28%, 8% and 4% of those interview performing AP25 o , AP20 o , and AP30 o cranial angulation, respectively. The comparison of error and repeat rates study demonstrated a lack of confidence, reduced employment of collimation and reduced accuracy while centring in the PA position and it was deemed necessary to repeat in 30% of cases compared to 40% repeats were necessary. Conclusion: Wide variation exists in technique and PA imaging is not being implemented. The author recommends training and information on PA technique be disseminated

  12. Short- and long-term reproducibility of radioisotopic examination of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Jonderko, K. (Silesian School of Medicine, Katowice (Poland). Dept. of Gastroenterology)

    1990-01-01

    Reproducibility of gastric emptying (GE) of a radiolabelled solid meal was assessed. The short-term reproducibility was evaluated on the basis of 12 paired GE examinations performed 1-3 days apart. Twelve paired GE examinations taken 3-8 months apart enabled long-term reproducibility assessment. Reproducibility of GE parameters was expressed in terms of the coefficient of variation, CV. No significant between-day variation of solid GE was found either regarding the short-term or the long-term reproducibility. Although slightly higher CV values characterized the long-term reproducibility of the GE parameters considered, the variations of the differences between repeated GE examinations did not differ significantly between short- and long-term GE reproducibility. The results obtained justify the use of radioisotopic GE measurement for the assessment of early and late results of pharmacologic or surgical management. (author).

  13. DNA Replication Dynamics of the GGGGCC Repeat of the C9orf72 Gene.

    Science.gov (United States)

    Thys, Ryan Griffin; Wang, Yuh-Hwa

    2015-11-27

    DNA has the ability to form a variety of secondary structures in addition to the normal B-form DNA, including hairpins and quadruplexes. These structures are implicated in a number of neurological diseases and cancer. Expansion of a GGGGCC repeat located at C9orf72 is associated with familial amyotrophic lateral sclerosis and frontotemporal dementia. This repeat expands from two to 24 copies in normal individuals to several hundreds or thousands of repeats in individuals with the disease. Biochemical studies have demonstrated that as little as four repeats have the ability to form a stable DNA secondary structure known as a G-quadruplex. Quadruplex structures have the ability to disrupt normal DNA processes such as DNA replication and transcription. Here we examine the role of GGGGCC repeat length and orientation on DNA replication using an SV40 replication system in human cells. Replication through GGGGCC repeats leads to a decrease in overall replication efficiency and an increase in instability in a length-dependent manner. Both repeat expansions and contractions are observed, and replication orientation is found to influence the propensity for expansions or contractions. The presence of replication stress, such as low-dose aphidicolin, diminishes replication efficiency but has no effect on instability. Two-dimensional gel electrophoresis analysis demonstrates a replication stall with as few as 20 GGGGCC repeats. These results suggest that replication of the GGGGCC repeat at C9orf72 is perturbed by the presence of expanded repeats, which has the potential to result in further expansion, leading to disease. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  14. Reliability of segmental accelerations measured using a new wireless gait analysis system.

    Science.gov (United States)

    Kavanagh, Justin J; Morrison, Steven; James, Daniel A; Barrett, Rod

    2006-01-01

    The purpose of this study was to determine the inter- and intra-examiner reliability, and stride-to-stride reliability, of an accelerometer-based gait analysis system which measured 3D accelerations of the upper and lower body during self-selected slow, preferred and fast walking speeds. Eight subjects attended two testing sessions in which accelerometers were attached to the head, neck, lower trunk, and right shank. In the initial testing session, two different examiners attached the accelerometers and performed the same testing procedures. A single examiner repeated the procedure in a subsequent testing session. All data were collected using a new wireless gait analysis system, which features near real-time data transmission via a Bluetooth network. Reliability for each testing condition (4 locations, 3 directions, 3 speeds) was quantified using a waveform similarity statistic known as the coefficient of multiple determination (CMD). CMD's ranged from 0.60 to 0.98 across all test conditions and were not significantly different for inter-examiner (0.86), intra-examiner (0.87), and stride-to-stride reliability (0.86). The highest repeatability for the effect of location, direction and walking speed were for the shank segment (0.94), the vertical direction (0.91) and the fast walking speed (0.91), respectively. Overall, these results indicate that a high degree of waveform repeatability was obtained using a new gait system under test-retest conditions involving single and dual examiners. Furthermore, differences in acceleration waveform repeatability associated with the reapplication of accelerometers were small in relation to normal motor variability.

  15. Repeatability, number of harvests, and phenotypic stability of dry matter yield and quality traits of Panicum maximum jacq.

    Directory of Open Access Journals (Sweden)

    Francisco Duarte Fernandes

    2017-04-01

    Full Text Available Selection of superior forage genotypes is based on agronomic traits assayed in repeated measures. The questions are how repeatable the performance of individual genotypes is and how many harvests are needed to select the best genotypes. The objectives were to estimate repeatability coefficients of dry matter yield (DMY and forage quality, their phenotypic stability and the number of harvests needed for an accurate selection. Two randomized complete block design experiments data with 24 genotypes each, undergoing 12 and 16 harvests, over a period of 2 and 3 years, respectively, were used. The DMY repeatability estimates ranged from 0.42 to 0.55, suggesting a low heritability. The mean numbers of repeated measures were 5 and 7 harvests for 0.80 and 0.85 accuracy, respectively. The inclusion of the first two harvests negatively affects the estimates. Repeatability for quality traits ranged from 0.30 to 0.69, indicating low to moderate heritability.

  16. Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes

    Science.gov (United States)

    Zavorsky, Gerald S.

    2010-01-01

    Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…

  17. Comparison of diet measures from a food-frequency questionnaire with measures from repeated 24-hour dietary recalls. The Norwegian Women and Cancer Study.

    Science.gov (United States)

    Hjartåker, Anette; Andersen, Lene Frost; Lund, Eiliv

    2007-10-01

    To compare diet measures from a food-frequency questionnaire (FFQ) with measures from 24-hour dietary recalls (24HDRs). The participants answered an FFQ after completing four, repeated 24HDRs during a year. Norway, nationwide. Of 500 women randomly selected from The Norwegian Women and Cancer Study (the Norwegian arm of the European Prospective Investigation into Cancer and Nutrition), 286 agreed to participate and 238 completed the study. On the group level, the FFQ overestimated absolute intake in seven and underestimated intake in six of 21 food groups. Intakes of energy, fat, added sugar and alcohol were lower in the FFQ than in the 24HDRs, whereas intake of fibre was higher. Spearman's rank correlation coefficient ranged from 0.13 (desserts) to 0.82 (coffee) for foods, and from 0.25 (beta-carotene) to 0.67 (alcohol) for nutrients. Three per cent of the observations on nutrient intake fell in the opposite quintile when classified according to the FFQ as compared with the 24HDR. The median calibration coefficient, calculated by regression of the 24HDR data on the FFQ data, was 0.57 for foods and 0.38 for nutrients. The FFQ's ability to rank subjects was good for foods eaten frequently and fairly good for macronutrients in terms of energy percentages. Weaker ranking abilities were seen for foods eaten infrequently and for some micronutrients. The results underline the necessity of performing measurement error corrections.

  18. Examination of the Correlation Between Foot Morphology Measurements Using Pedography and Radiographic Measurements.

    Science.gov (United States)

    Inui, Kentaro; Ikoma, Kazuya; Imai, Kan; Ohashi, Suzuyo; Maki, Masahiro; Kido, Masamitsu; Hara, Yusuke; Oka, Yoshinobu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    Pedography provides excellent visualization of the footprint. However, the correlation between the footprint images and radiographic measures has not been thoroughly evaluated. Therefore, the objectives of our study were to examine the correlation between the pedography-based measures of foot morphology and radiographic measurements and to propose reference values for the diagnosis of flatfoot using footprint imaging. The plantar footprints of 100 right feet were photographed using a pedography standing platform. The sole and arch areas were measured to calculate the footprint index (FPI). The lateral talar-first metatarsal angle (LTM) and calcaneal pitch angle (CP) were measured on standing lateral radiographs, and the talonavicular coverage angle was measured on frontal radiographs. The Pearson moment correlation between the FPI and radiography-based measures was calculated. The area under the receiver operating characteristic curve was calculated using an LTM of <-4° as the identifying criterion of flatfoot. The sensitivity and specificity of FPI were calculated for LTM values <-4°. The FPI correlated with the LTM (y = -17.964 ± 52.644x, R = 0.588) and CP (y = 9.2304 ± 27.739x, R = 0.659) but not with the talonavicular coverage angle (y = 26.01 ± 15.78x, R = 0.207). The area under the receiver operating characteristic curve was 0.753, with a cutoff FPI of 0.208, yielding a sensitivity of 0.462 and specificity of 0.934 for flatfoot identification. Pedography could provide an easy screening tool for flatfoot, with an FPI cutoff of 0.208, yielding a specificity of 93.4%. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability and sensitivity in pediatric planovalgus feet.

    Science.gov (United States)

    Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B; D'Astous, Jacques L

    2013-01-01

    Several multisegment foot models have been proposed and some have been used to study foot pathologies. These models have been tested and validated on typically developed populations; however application of such models to feet with significant deformities presents an additional set of challenges. For the first time, in this study, a multisegment foot model is tested for repeatability in a population of children with symptomatic abnormal feet. The results from this population are compared to the same metrics collected from an age matched (8-14 years) typically developing population. The modified Shriners Hospitals for Children, Greenville (mSHCG) foot model was applied to ten typically developing children and eleven children with planovalgus feet by two clinicians. Five subjects in each group were retested by both clinicians after 4-6 weeks. Both intra-clinician and inter-clinician repeatability were evaluated using static and dynamic measures. A plaster mold method was used to quantify variability arising from marker placement error. Dynamic variability was measured by examining trial differences from the same subjects when multiple clinicians carried out the data collection multiple times. For hindfoot and forefoot angles, static and dynamic variability in both groups was found to be less than 4° and 6° respectively. The mSHCG model strategy of minimal reliance on anatomical markers for dynamic measures and inherent flexibility enabled by separate anatomical and technical coordinate systems resulted in a model equally repeatable in typically developing and planovalgus populations. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Repeated mild closed head injury impairs short-term visuospatial memory and complex learning.

    Science.gov (United States)

    Hylin, Michael J; Orsi, Sara A; Rozas, Natalia S; Hill, Julia L; Zhao, Jing; Redell, John B; Moore, Anthony N; Dash, Pramod K

    2013-05-01

    Concussive force can cause neurocognitive and neurobehavioral dysfunction by inducing functional, electrophysiological, and/or ultrastructural changes within the brain. Although concussion-triggered symptoms typically subside within days to weeks in most people, in 15%-20% of the cases, symptomology can continue beyond this time point. Problems with memory, attention, processing speed, and cognitive flexibility (e.g., problem solving, conflict resolution) are some of the prominent post-concussive cognitive symptoms. Repeated concussions (with loss or altered consciousness), which are common to many contact sports, can exacerbate these symptoms. The pathophysiology of repeated concussions is not well understood, nor is an effective treatment available. In order to facilitate drug discovery to treat post-concussive symptoms (PCSs), there is a need to determine if animal models of repeated mild closed head injury (mCHI) can mimic the neurocognitive and histopathological consequences of repeated concussions. To this end, we employed a controlled cortical impact (CCI) device to deliver a mCHI directly to the skull of mice daily for 4 days, and examined the ensuing neurological and neurocognitive functions using beam balance, foot-fault, an abbreviated Morris water maze test, context discrimination, and active place avoidance tasks. Repeated mCHI exacerbated vestibulomotor, motor, short-term memory and conflict learning impairments as compared to a single mCHI. Learning and memory impairments were still observed in repeated mCHI mice when tested 3 months post-injury. Repeated mCHI also reduced cerebral perfusion, prolonged the inflammatory response, and in some animals, caused hippocampal neuronal loss. Our results show that repeated mCHI can reproduce some of the deficits seen after repeated concussions in humans and may be suitable for drug discovery studies and translational research.

  1. Effect of repeated burning on plant and soil carbon and nitrogen in cheatgrass (Bromus tectorum) dominated ecosystems

    Science.gov (United States)

    Rachel Jones; Jeanne C. Chambers; Dale W. Johnson; Robert R. Blank; David I. Board

    2015-01-01

    Fire has profound effects on ecosystem properties, but few studies have addressed the effect of repeated burns on soil nutrients, and none have been conducted in cold desert ecosystems where invasion by exotic annual grasses is resulting in greater fire frequency. In a 5 year study, we examined effects of repeated burning, litter removal, and post-fire seeding on...

  2. Unusual structures are present in DNA fragments containing super-long Huntingtin CAG repeats.

    Directory of Open Access Journals (Sweden)

    Daniel Duzdevich

    2011-02-01

    Full Text Available In the R6/2 mouse model of Huntington's disease (HD, expansion of the CAG trinucleotide repeat length beyond about 300 repeats induces a novel phenotype associated with a reduction in transcription of the transgene.We analysed the structure of polymerase chain reaction (PCR-generated DNA containing up to 585 CAG repeats using atomic force microscopy (AFM. As the number of CAG repeats increased, an increasing proportion of the DNA molecules exhibited unusual structural features, including convolutions and multiple protrusions. At least some of these features are hairpin loops, as judged by cross-sectional analysis and sensitivity to cleavage by mung bean nuclease. Single-molecule force measurements showed that the convoluted DNA was very resistant to untangling. In vitro replication by PCR was markedly reduced, and TseI restriction enzyme digestion was also hindered by the abnormal DNA structures. However, significantly, the DNA gained sensitivity to cleavage by the Type III restriction-modification enzyme, EcoP15I."Super-long" CAG repeats are found in a number of neurological diseases and may also appear through CAG repeat instability. We suggest that unusual DNA structures associated with super-long CAG repeats decrease transcriptional efficiency in vitro. We also raise the possibility that if these structures occur in vivo, they may play a role in the aetiology of CAG repeat diseases such as HD.

  3. Repeatability and comparison of clinical techniques for anterior chamber angle assessment.

    Science.gov (United States)

    Campbell, Peter; Redmond, Tony; Agarwal, Rishi; Marshall, Lewis R; Evans, Bruce J W

    2015-03-01

    To assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. Gonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1 month apart, on 80 subjects aged over 40 years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840 nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa (κ) was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. Measurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair κ = 0.29, while that of the van Herick method (κ = 0.54) and AS-OCT (κ = 0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). Intra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more

  4. EXAMINATION ABOUT INFLUENCE FOR PRECISION OF 3D IMAGE MEASUREMENT FROM THE GROUND CONTROL POINT MEASUREMENT AND SURFACE MATCHING

    Directory of Open Access Journals (Sweden)

    T. Anai

    2015-05-01

    Full Text Available As the 3D image measurement software is now widely used with the recent development of computer-vision technology, the 3D measurement from the image is now has acquired the application field from desktop objects as wide as the topography survey in large geographical areas. Especially, the orientation, which used to be a complicated process in the heretofore image measurement, can be now performed automatically by simply taking many pictures around the object. And in the case of fully textured object, the 3D measurement of surface features is now done all automatically from the orientated images, and greatly facilitated the acquisition of the dense 3D point cloud from images with high precision. With all this development in the background, in the case of small and the middle size objects, we are now furnishing the all-around 3D measurement by a single digital camera sold on the market. And we have also developed the technology of the topographical measurement with the air-borne images taken by a small UAV [1~5]. In this present study, in the case of the small size objects, we examine the accuracy of surface measurement (Matching by the data of the experiments. And as to the topographic measurement, we examine the influence of GCP distribution on the accuracy by the data of the experiments. Besides, we examined the difference of the analytical results in each of the 3D image measurement software. This document reviews the processing flow of orientation and the 3D measurement of each software and explains the feature of the each software. And as to the verification of the precision of stereo-matching, we measured the test plane and the test sphere of the known form and assessed the result. As to the topography measurement, we used the air-borne image data photographed at the test field in Yadorigi of Matsuda City, Kanagawa Prefecture JAPAN. We have constructed Ground Control Point which measured by RTK-GPS and Total Station. And we show the results

  5. Examination about Influence for Precision of 3d Image Measurement from the Ground Control Point Measurement and Surface Matching

    Science.gov (United States)

    Anai, T.; Kochi, N.; Yamada, M.; Sasaki, T.; Otani, H.; Sasaki, D.; Nishimura, S.; Kimoto, K.; Yasui, N.

    2015-05-01

    As the 3D image measurement software is now widely used with the recent development of computer-vision technology, the 3D measurement from the image is now has acquired the application field from desktop objects as wide as the topography survey in large geographical areas. Especially, the orientation, which used to be a complicated process in the heretofore image measurement, can be now performed automatically by simply taking many pictures around the object. And in the case of fully textured object, the 3D measurement of surface features is now done all automatically from the orientated images, and greatly facilitated the acquisition of the dense 3D point cloud from images with high precision. With all this development in the background, in the case of small and the middle size objects, we are now furnishing the all-around 3D measurement by a single digital camera sold on the market. And we have also developed the technology of the topographical measurement with the air-borne images taken by a small UAV [1~5]. In this present study, in the case of the small size objects, we examine the accuracy of surface measurement (Matching) by the data of the experiments. And as to the topographic measurement, we examine the influence of GCP distribution on the accuracy by the data of the experiments. Besides, we examined the difference of the analytical results in each of the 3D image measurement software. This document reviews the processing flow of orientation and the 3D measurement of each software and explains the feature of the each software. And as to the verification of the precision of stereo-matching, we measured the test plane and the test sphere of the known form and assessed the result. As to the topography measurement, we used the air-borne image data photographed at the test field in Yadorigi of Matsuda City, Kanagawa Prefecture JAPAN. We have constructed Ground Control Point which measured by RTK-GPS and Total Station. And we show the results of analysis made

  6. The risk of X-ray examinations of the lungs in neonates

    International Nuclear Information System (INIS)

    Arroee, M.

    1991-01-01

    X-ray examinations of the lungs is an important element in the evaluation of the neonates and their respiratory function. It is often necessary to perform a large number of X-ray examinations depending upon the infant's birthweight, gestational age and respiratory problems. To estimate the risk of X-ray examinations of the lungs the radiation dose to 18 infants at the Neonatal Intensive Care Univ, Hvidovre Hospital, was measured by means of the thermoluminescent dosimeter placed on the nipple of the infant. The radiation dose to various organs was estimated and the risk weighted whole body radiation dose calculated to 40 microsievert per examination (AP- and lateral). Using the latest increased risk factors this means an excess cancer mortality of 5x10 -5 for boys abd 11x10 -5 for girls per millisievert, corresponding to 25 X-ray examinations (AP- and lateral) of the lungs. It is concluded, that even using the latest increased risk factors, the radiation risk of repeated X-ray examinations of the chest in prematures will be very low considering the benefit for the infant. (au)

  7. The Predictive Validity of the ABFM's In-Training Examination.

    Science.gov (United States)

    O'Neill, Thomas R; Li, Zijia; Peabody, Michael R; Lybarger, Melanie; Royal, Kenneth; Puffer, James C

    2015-05-01

    Our objective was to examine the predictive validity of the American Board of Family Medicine's (ABFM) In-Training Examination (ITE) with regard to predicting outcomes on the ABFM certification examination. This study used a repeated measures design across three levels of medical training (PGY1--PGY2, PGY2--PGY3, and PGY3--initial certification) with three different cohorts (2010--2011, 2011--2012, and 2012--2013) to examine: (1) how well the residents' ITE scores correlated with their test scores in the following year, (2) what the typical score increase was across training years, and (3) what was the sensitivity, specificity, positive predictive value, and negative predictive value of the PGY3 scores with regard to predicting future results on the MC-FP Examination. ITE scores generally correlate at about .7 with the following year's ITE or with the following year's certification examination. The mean growth from PGY1 to PGY2 was 52 points, from PGY2 to PGY3 was 34 points, and from PGY3 to initial certification was 27 points. The sensitivity, specificity, positive predictive value, and negative predictive value were .91, .47, .96, and .27, respectively. The ITE is a useful predictor of future ITE and initial certification examination performance.

  8. Repeating Marx

    DEFF Research Database (Denmark)

    Fuchs, Christian; Monticelli, Lara

    2018-01-01

    This introduction sets out the context of the special issue “Karl Marx @ 200: Debating Capitalism & Perspectives for the Future of Radical Theory”, which was published on the occasion of Marx’s bicentenary on 5 May 2018. First, we give a brief overview of contemporary capitalism’s development...... and its crises. Second, we argue that it is important to repeat Marx today. Third, we reflect on lessons learned from 200 years of struggles for alternatives to capitalism. Fourth, we give an overview of the contributions in this special issue. Taken together, the contributions in this special issue show...... that Marx’s theory and politics remain key inspirations for understanding exploitation and domination in 21st-century society and for struggles that aim to overcome these phenomena and establishing a just and fair society. We need to repeat Marx today....

  9. Determination of internal series resistance of PV devices: repeatability and uncertainty

    International Nuclear Information System (INIS)

    Trentadue, Germana; Pavanello, Diego; Salis, Elena; Field, Mike; Müllejans, Harald

    2016-01-01

    The calibration of photovoltaic devices requires the measurement of their current–voltage characteristics at standard test conditions (STC). As the latter can only be reached approximately, a curve translation is necessary, requiring among others the internal series resistance of the photovoltaic device as an input parameter. Therefore accurate and reliable determination of the series resistance is important in measurement and test laboratories. This work follows standard IEC 60891 ed 2 (2009) for the determination of the internal series resistance and investigates repeatability and uncertainty of the result in three aspects for a number of typical photovoltaic technologies. Firstly the effect of varying device temperature on the determined series resistance is determined experimentally and compared to a theoretical derivation showing agreement. It is found that the series resistance can be determined with an uncertainty of better than 5% if the device temperature is stable within  ±0.1 °C, whereas the temperature range of  ±2 °C allowed by the standard leads to much larger variations. Secondly the repeatability of the series resistance determination with respect to noise in current–voltage measurement is examined yielding typical values of  ±5%. Thirdly the determination of the series resistance using three different experimental set-ups (solar simulators) shows agreement on the level of  ±5% for crystalline Silicon photovoltaic devices and deviations up to 15% for thin-film devices. It is concluded that the internal series resistance of photovoltaic devices could be determined with an uncertainty of better than 10%. The influence of this uncertainty in series resistance on the electrical performance parameters of photovoltaic devices was estimated and showed a contribution of 0.05% for open-circuit voltage and 0.1% for maximum power. Furthermore it is concluded that the range of device temperatures allowed during determination of series

  10. Examination of the effect of the annealing cation on higher order structures containing guanine or isoguanine repeats

    Science.gov (United States)

    Pierce, Sarah E.; Wang, Junmei; Jayawickramarajah, Janarthanan; Hamilton, Andrew D.; Brodbelt, Jennifer S.

    2010-01-01

    Isoguanine (2-oxo-6-amino-guanine), a natural but non-standard base, exhibits unique self-association properties compared to its isomer, guanine, and results in formation of different higher order DNA structures. In this work, the higher order structures formed by oligonucleotides containing guanine repeats or isoguanine repeats after annealing in solutions containing various cations are evaluated by electrospray ionization mass spectrometry (ESI-MS) and circular dichroism (CD) spectroscopy. The guanine-containing strand (G9) consistently formed quadruplexes upon annealing, whereas the isoguanine strand (Ig9) formed both pentaplexes and quadruplexes depending on the annealing cation. Quadruplex formation with G9 showed some dependence on the identity of the cation present during annealing with high relative quadruplex formation detected with six of ten cations. Analogous annealing experiments with Ig9 resulted in complex formation with all ten cations, and the majority of the resulting complexes were pentaplexes. CD results indicated most of the original complexes survived the desalting process necessary for ESI-MS analysis. In addition, several complexes, especially the pentaplexes, were found to be capable of cation exchange with ammonium ions. Ab initio calculations were conducted for isoguanine tetrads and pentads coordinated with all ten cations to predict the most energetically stable structures of the complexes in the gas phase. The observed preference of forming quadruplexes versus pentaplexes as a function of the coordinated cation can be interpreted by the calculated reaction energies of both the tetrads and pentads in combination with the distortion energies of tetrads. PMID:19746468

  11. An Examination of Disciplinary Procedures with Children

    Science.gov (United States)

    Forehand, Rex; And Others

    1976-01-01

    Experiment 1 examined the effect of negative attention and repeated demands on the noncompliant behavior of children. Experiment 2 studied the relative effectiveness of negative attention, isolation, ignoring, and a combination of procedures in reducing noncompliance in children. (GO)

  12. Repeat immigration: A previously unobserved source of heterogeneity?

    Science.gov (United States)

    Aradhya, Siddartha; Scott, Kirk; Smith, Christopher D

    2017-07-01

    Register data allow for nuanced analyses of heterogeneities between sub-groups which are not observable in other data sources. One heterogeneity for which register data is particularly useful is in identifying unique migration histories of immigrant populations, a group of interest across disciplines. Years since migration is a commonly used measure of integration in studies seeking to understand the outcomes of immigrants. This study constructs detailed migration histories to test whether misclassified migrations may mask important heterogeneities. In doing so, we identify a previously understudied group of migrants called repeat immigrants, and show that they differ systematically from permanent immigrants. In addition, we quantify the degree to which migration information is misreported in the registers. The analysis is carried out in two steps. First, we estimate income trajectories for repeat immigrants and permanent immigrants to understand the degree to which they differ. Second, we test data validity by cross-referencing migration information with changes in income to determine whether there are inconsistencies indicating misreporting. From the first part of the analysis, the results indicate that repeat immigrants systematically differ from permanent immigrants in terms of income trajectories. Furthermore, income trajectories differ based on the way in which years since migration is calculated. The second part of the analysis suggests that misreported migration events, while present, are negligible. Repeat immigrants differ in terms of income trajectories, and may differ in terms of other outcomes as well. Furthermore, this study underlines that Swedish registers provide a reliable data source to analyze groups which are unidentifiable in other data sources.

  13. Repeated bonding of fixed retainer increases the risk of enamel fracture.

    Science.gov (United States)

    Chinvipas, Netrporn; Hasegawa, Yuh; Terada, Kazuto

    2014-01-01

    The aim of this study was to investigate the influences of repeated bonding, using 2 different orthodontic adhesive systems, on the shear bond strength (SBS) and the enamel surface morphology. Sixty premolars were divided into 2 groups (n = 30), and either Transbond XT (T group) or Fuji Ortho LC (F group) adhesives were used. SBS was measured 24 h after bonding, using a universal testing machine. Then, the enamel surfaces were investigated and the mode of failure was described using adhesive remnant index (ARI) scores. After each debonding, 10 teeth from each group were examined by scanning electron microscopy to determine the penetration of adhesives, the length of resin tags, and the state of the enamel surface. The other teeth were subjected to two more bonding/debonding procedures. In T group, the second debonding sequences had significantly higher bond strengths than the other sequences. The length of resin tags was greatest in the second debonding sequence, although there was no significant difference. In F group, the SBS increased with further rebonding and the failure mode tended towards cohesive failure. In both groups, the ARI scores increased with rebonding. Enamel loss could have occurred with both adhesives, although the surfaces appeared unchanged to the naked eye. From this study, we suggest that enamel damage caused by repeated bonding is of concern. To prevent bond failure, we should pay attention to the adhesion method used for bondable retainers.

  14. Genome-wide analysis of tandem repeats in plants and green algae

    Science.gov (United States)

    Zhixin Zhao; Cheng Guo; Sreeskandarajan Sutharzan; Pei Li; Craig Echt; Jie Zhang; Chun Liang

    2014-01-01

    Tandem repeats (TRs) extensively exist in the genomes of prokaryotes and eukaryotes. Based on the sequenced genomes and gene annotations of 31 plant and algal species in Phytozome version 8.0 (http://www.phytozome.net/), we examined TRs in a genome-wide scale, characterized their distributions and motif features, and explored their putative biological functions. Among...

  15. Repeat-associated plasticity in the Helicobacter pylori RD gene family.

    Science.gov (United States)

    Shak, Joshua R; Dick, Jonathan J; Meinersmann, Richard J; Perez-Perez, Guillermo I; Blaser, Martin J

    2009-11-01

    The bacterium Helicobacter pylori is remarkable for its ability to persist in the human stomach for decades without provoking sterilizing immunity. Since repetitive DNA can facilitate adaptive genomic flexibility via increased recombination, insertion, and deletion, we searched the genomes of two H. pylori strains for nucleotide repeats. We discovered a family of genes with extensive repetitive DNA that we have termed the H. pylori RD gene family. Each gene of this family is composed of a conserved 3' region, a variable mid-region encoding 7 and 11 amino acid repeats, and a 5' region containing one of two possible alleles. Analysis of five complete genome sequences and PCR genotyping of 42 H. pylori strains revealed extensive variation between strains in the number, location, and arrangement of RD genes. Furthermore, examination of multiple strains isolated from a single subject's stomach revealed intrahost variation in repeat number and composition. Despite prior evidence that the protein products of this gene family are expressed at the bacterial cell surface, enzyme-linked immunosorbent assay and immunoblot studies revealed no consistent seroreactivity to a recombinant RD protein by H. pylori-positive hosts. The pattern of repeats uncovered in the RD gene family appears to reflect slipped-strand mispairing or domain duplication, allowing for redundancy and subsequent diversity in genotype and phenotype. This novel family of hypervariable genes with conserved, repetitive, and allelic domains may represent an important locus for understanding H. pylori persistence in its natural host.

  16. A repeat-until-success quantum computing scheme

    Energy Technology Data Exchange (ETDEWEB)

    Beige, A [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom); Lim, Y L [DSO National Laboratories, 20 Science Park Drive, Singapore 118230, Singapore (Singapore); Kwek, L C [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542, Singapore (Singapore)

    2007-06-15

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes.

  17. A repeat-until-success quantum computing scheme

    International Nuclear Information System (INIS)

    Beige, A; Lim, Y L; Kwek, L C

    2007-01-01

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes

  18. IDA NOMEX: examination of emergency protective measures in Switzerland

    International Nuclear Information System (INIS)

    2012-06-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) presents the results of work carried out by the Swiss Interdepartmental Working Group on Emergency Protective Measures for Extreme Incidents IDA NOMEX after the nuclear incident in Fukushima, Japan. The first three chapters deal with the initial situation after the incidents in Fukushima. The mandate issued by the Swiss Federal Government to IDA NOMEX and its implementation are discussed. Topics covered include data on the personnel and materials required to deal with nuclear incidents, details with reference to the Swiss Radiation Protection Ordinance, tasks of the various state agencies along with the interfaces between them, lessons learned from the nuclear accident in Fukushima, current deficits in the various organisations and measures to be taken as well as a master plan and its implementation. The testing of the various reference scenarios proposed is discussed and various measures, such as evacuation concepts and the distribution of iodine tablets, are looked at in detail. The international situation is examined and co-operation within Europe and also with international bodies is looked at. Finally the required resources are discussed and further work to be done is looked at. Appendices complete the report

  19. Repeated irradiations with γ-rays at a dose of 0.5 Gy may exacerbate asthma

    International Nuclear Information System (INIS)

    Fang, Su-ping; Tago, Fumitoshi; Tanaka, Takashi; Simura, Noriko; Kojima, Shuji; Muto, Yasuko; Goto, Resuke

    2005-01-01

    We previously showed that 0.5 Gy whole-body γ-ray irradiation with a single or small number of repeated exposures inhibits tumor growth in mice, via elevation of the IFNγ/IL-4 ratio concomitantly with a decrease in the percentage of B cells. Here we examined whether repeated 0.5 Gy γ-rays irradiation can improve asthma in an ovalbumin (OVA)-induced asthmatic mouse model. We found that repeated irradiation (10 times) with 0.5 Gy of γ-rays significantly increased total IgE in comparison with the disease-control group. The levels of IL-4 and IL-5 were also significantly higher in the γ-ray-irradiated group, while that of IFN-γ was significantly lower, resulting in a further decrease of the IFN-γ/IL-4 ratio from the normal value. These results indicate that the repeated irradiation with γ-rays may exacerbate asthma, and may have opposite effects on different immune reactions unlike the irradiation with a single or small number of repeated exposures. (author)

  20. Readout Distance Enhancement of the Passive Wireless Multi-Parameter Sensing System Using a Repeater Coil

    Directory of Open Access Journals (Sweden)

    Lifeng Wang

    2018-01-01

    Full Text Available A repeater coil is used to extend the detection distance of a passive wireless multi-parameter sensing system. The passive wireless sensing system has the ability of simultaneously monitoring three parameters by using backscatter modulation together with channel multiplexing. Two different repeater coils are designed and fabricated for readout distance enhancement of the sensing system: one is a PCB (printed circuit board repeater coil, and the other is a copper wire repeater coil. Under the conditions of fixed voltage and adjustable voltage, the maximum readout distance of the sensing system with and without a repeater coil is measured. Experimental results show that larger power supply voltage can help further increase the readout distance. The maximum readout distance of the sensing system with a PCB repeater coil has been extended 2.3 times, and the one with a copper wire repeater coil has been extended 3 times. Theoretical analysis and experimental results both indicate that the high Q factor repeater coil can extend the readout distance more. With the copper wire repeater coil as well as a higher power supply voltage, the passive wireless multi-parameter sensing system finally achieves a maximum readout distance of 13.5 cm.

  1. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  2. Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.

    Science.gov (United States)

    Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L

    2012-04-01

    Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Repeated Strains, Social Control, Social Learning, and Delinquency: Testing an Integrated Model of General Strain Theory in China

    Science.gov (United States)

    Bao, Wan-Ning; Haas, Ain; Chen, Xiaojin; Pi, Yijun

    2014-01-01

    In Agnew's general strain theory, repeated strains can generate crime and delinquency by reducing social control and fostering social learning of crime. Using a sample of 615 middle-and high-school students in China, this study examines how social control and social learning variables mediate the effect of repeated strains in school and at home on…

  4. TRIM timber projections: an evaluation based on forest inventory measurements.

    Science.gov (United States)

    John R. Mills

    1989-01-01

    Two consecutive timberland inventories collected from permanent plots in the natural pine type in North Carolina were used to evaluate the timber resource inventory model (TRIM). This study compares model predictions with field measurements and examines the effect of inventory data aggregation on the accuracy of projections. Projections were repeated for two geographic...

  5. Examining Impulse-Variability in Kicking.

    Science.gov (United States)

    Chappell, Andrew; Molina, Sergio L; McKibben, Jonathon; Stodden, David F

    2016-07-01

    This study examined variability in kicking speed and spatial accuracy to test the impulse-variability theory prediction of an inverted-U function and the speed-accuracy trade-off. Twenty-eight 18- to 25-year-old adults kicked a playground ball at various percentages (50-100%) of their maximum speed at a wall target. Speed variability and spatial error were analyzed using repeated-measures ANOVA with built-in polynomial contrasts. Results indicated a significant inverse linear trajectory for speed variability (p < .001, η2= .345) where 50% and 60% maximum speed had significantly higher variability than the 100% condition. A significant quadratic fit was found for spatial error scores of mean radial error (p < .0001, η2 = .474) and subject-centroid radial error (p < .0001, η2 = .453). Findings suggest variability and accuracy of multijoint, ballistic skill performance may not follow the general principles of impulse-variability theory or the speed-accuracy trade-off.

  6. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    Directory of Open Access Journals (Sweden)

    Sha-Sha Yu

    2017-11-01

    Full Text Available AIM: To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL-Master and LenstarLS900 (Lenstar in measuring corneal parameters among cataract patients. METHODS: Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf, the steepest meridian power (Ks, mean power (Km, J0 and J45 were recorded. Intra-class correlation coefficients (ICCs, the coefficient of variance (COV, within subject standard deviation (Sw, and test-retest repeatability (2.77Sw were adopted to determine the repeatability. The 95% limit of agreement (95%LOA and Bland-Altman plots were used to assess comparability. RESULTS: Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION: Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  7. simple sequence repeats (EST-SSR)

    African Journals Online (AJOL)

    Yomi

    2012-01-19

    Jan 19, 2012 ... 212 primer pairs selected, based on repeat patterns of n≥8 for di-, tri-, tetra- and penta-nucleotide repeat ... Cluster analysis revealed a high genetic similarity among the sugarcane (Saccharum spp.) breeding lines which could reduce the genetic gain in ..... The multiple allele characteristic of SSR com-.

  8. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  9. Repeated Prescribed Burning in Aspen

    Science.gov (United States)

    Donald A. Perala

    1974-01-01

    Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.

  10. Some anemonefish lack personality: a comparative assessment of behavioral variation and repeatability in relation to environmental and social factors

    Science.gov (United States)

    Wong, Marian Y. L.; Beasley, Amanda L.; Douglass, Tasman; Whalan, Steve; Scott, Anna

    2017-12-01

    Determining the extent of repeatable differences in the behavior of animals and the factors that influence behavioral expression is important for understanding individual fitness and population processes, thereby aiding in species conservation. However, little is known about the causes of variation in the repeatability of behavioral differences among species because rarely have comparative studies been undertaken to examine the repeatability of behavioral differences among individuals within their natural ecological settings. Using two species of endemic subtropical anemonefishes, Amphiprion mccullochi and A. latezonatus at Lord Howe and North Solitary Islands, Australia, we conducted an in situ comparative analysis of personality traits, examining the repeatability of boldness, sociability and aggression as well as the potential role of environmental and social factors on behavioral expression. For A. mccullochi, only boldness and aggression were highly repeatable and these behaviors formed a behavioral syndrome. For A. latezonatus, none of the three behaviors were repeatable due to low-inter-individual variation in behavior. We suggest that the harsher and more variable environmental and social conditions experienced by A. latezonatus have resulted in reduced repeatability in behavior, in contrast to A. mccullochi which typically inhabits a more stable lagoonal reef environment. Additionally, group size and size rank, rather than nearest-neighbor distance and anemone size, influenced the expression of these behaviors in both species, suggesting that behavioral variation was more sensitive to social than environmental factors. Overall, differences in repeatability between these closely related species likely reflect adaptations to contrasting environmental and social conditions, although alternative explanations must be considered. The differences in behavioral consistency between these two endemic anemonefishes could lead to disparity in their resilience to

  11. Regret in repeat purchase versus switching decisions : The attenuating role of decision justifiability

    NARCIS (Netherlands)

    Inman, J.J.; Zeelenberg, M.

    2002-01-01

    The decision-making literature has consistently reported that decisions to maintain the status quo tend to be regretted less than decisions to change it. We examine the consequences of repeat purchasing (maintaining the status quo) versus switching in the context of information regarding the reason

  12. Repeat Colonoscopy within 6 Months after Initial Outpatient Colonoscopy in Ontario: A Population-Based Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Lawrence Paszat

    2017-01-01

    Full Text Available Background. The goal of this study is to examine utilization of early repeat colonoscopy ≤ 6 months after an index procedure. Methods. We identified persons having repeat colonoscopy ≤ 6 months following outpatient colonoscopy without prior colonoscopy ≤ 5 years or prior diagnosis of colorectal cancer (CRC. We modeled repeat colonoscopy using a generalized estimating equation with an exchangeable correlation structure to account for clustering of patients by endoscopist. Results. The population included 334,663 persons, 7,892 (2.36% of whom had an early repeat colonoscopy within 6 months. Overall, endoscopist prior year colonoscopy volume was inversely related to repeat ≤ 6 months. Repeat colonoscopy ≤ 6 months varied by the clinical setting of the index colonoscopy (adjusted OR = 1.41 (95% CI 1.29–1.55 at nonhospital facilities compared to teaching or community hospitals. Among those who had polypectomy or biopsy, the adjusted OR for early repeat ≤ 6 months was elevated among those whose index colonoscopy was at a nonhospital facility (OR 1.44, 95% CI 1.30–1.60, compared to those at a teaching hospital or community hospital. Conclusions. Repeat colonoscopy ≤ 6 months after an index procedure is associated with the clinical setting of the index colonoscopy.

  13. Investigation of cerebral hemodynamic changes during repeated sit-stand maneuver using functional near-infrared spectroscopy

    Science.gov (United States)

    Niu, Haijing; Li, Lin; Bhave, Gauri S.; Lin, Zi-jing; Tian, Fenghua; Khosrow, Behbehani; Zhang, Rong; Liu, Hanli

    2011-03-01

    The goal for this study is to examine cerebral autoregulation in response to a repeated sit-stand maneuver using both diffuse functional Near Infrared spectroscopy (fNIRS) and Transcranial Doppler sonography (TCD). While fNIRS can provide transient changes in hemodynamic response to such a physical action, TCD is a noninvasive transcranial method to detect the flow velocities in the basal or middle cerebral arteries (MCA). The initial phase of this study was to measure fNIRS signals from the forehead of subjects during the repeated sit-stand protocol and to understand the corresponding meaning of the detected signals. Also, we acquired preliminary data from simultaneous measurements of fNIRS and TCD during the sit-stand protocol so as to explore the technical difficulty of such an approach. Specifically, ten healthy adult subjects were enrolled to perform the planned protocol, and the fNIRS array probes with 4 sources and 10 detectors were placed on the subject's forehead to detect hemodynamic signal changes from the prefrontal cortex. The fNIRS results show that the oscillations of hemoglobin concentration were spatially global and temporally dynamic across the entire region of subject's forehead. The oscillation patterns in both hemoglobin concentrations and blood flow velocity seemed to follow one another; changes in oxy-hemoglobin concentration were much larger than those in deoxyhemoglobin concentration. These preliminary findings provide us with evidence that fNIRS is an appropriate means readily for studying cerebral hemodynamics and autoregulation during sit-stand maneuvers.

  14. What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?

    Science.gov (United States)

    Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E

    2018-03-01

    Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.

  15. Individual differences and repeatability in vocal production: stress-induced calling exposes a songbird's personality

    Science.gov (United States)

    Guillette, Lauren M.; Sturdy, Christopher B.

    2011-11-01

    Recent research in songbirds has demonstrated that male singing behavior varies systematically with personality traits such as exploration and risk taking. Here we examine whether the production of bird calls, in addition to bird songs, is repeatable and related to exploratory behavior, using the black-capped chickadee ( Poecile atricapillus) as a model. We assessed the exploratory behavior of individual birds in a novel environment task. We then recorded the vocalizations and accompanying motor behavior of both male and female chickadees, over the course of several days, in two different contexts: a control condition with no playback and a stressful condition where chick-a-dee mobbing calls were played to individual birds. We found that several vocalizations and behaviors were repeatable within both a control and a stressful context, and across contexts. While there was no relationship between vocal output and exploratory behavior in the control context, production of alarm and chick-a-dee calls in the stressful condition was positively associated with exploratory behavior. These findings are important because they show that bird calls, in addition to bird song, are an aspect of personality, in that calls are consistent both within and across contexts, and covary with other personality measures (exploration).

  16. The effects of a repeated bout of eccentric exercise on indices of muscle damage and delayed onset muscle soreness.

    Science.gov (United States)

    Paddon-Jones, D; Muthalib, M; Jenkins, D

    2000-03-01

    This study examined markers of muscle damage following a repeated bout of maximal isokinetic eccentric exercise performed prior to full recovery from a previous bout. Twenty non-resistance trained volunteers were randomly assigned to a control (CON, n=10) or experimental (EXP, n=10) group. Both groups performed 36 maximal isokinetic eccentric contractions of the elbow flexors of the non-dominant arm (ECC1). The EXP group repeated the same eccentric exercise bout two days later (ECC2). Total work and peak eccentric torque were recorded during each set of ECC1 and ECC2. Isometric torque, delayed onset muscle soreness (DOMS), flexed elbow angle and plasma creatine kinase (CK) activity were measured prior to and immediately following ECC1 and ECC2. at 24h intervals for 7 days following ECC1 and finally on day 11. In both groups, all dependent variables changed significantly during the 2 days following ECC1. A further acute post-exercise impairment in isometric torque (30 +/- 5%) and flexed elbow angle (20 +/- 4%) was observed following ECC2 (p0.05). These findings suggest that when maximal isokinetic eccentric exercise is repeated two days after experiencing of contraction-induced muscle damage, the recovery time course is not significantly altered.

  17. Thermal stability of chicken brain {alpha}-spectrin repeat 17: a spectroscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Annette K. [University of Bergen, Department of Chemistry (Norway); Kieffer, Bruno [Ecole Superieure de Biotechnologie de Strasbourg, IGBMC Biomolecular NMR Group, CNRS UMR 7104 (France); Trave, Gilles [Ecole Superieure de Biotechnologie de Strasbourg, Equipe Oncoproteines, IREBS, UMR 7242 (France); Froystein, Nils Age [University of Bergen, Department of Chemistry (Norway); Raae, Arnt J., E-mail: arnt.raae@mbi.uib.no [University of Bergen, Department of Molecular Biology (Norway)

    2012-06-15

    Spectrin is a rod-like multi-modular protein that is mainly composed of triple-helical repeats. These repeats show very similar 3D-structures but variable conformational and thermodynamical stabilities, which may be of great importance for the flexibility and dynamic behaviour of spectrin in the cell. For instance, repeat 17 (R17) of the chicken brain spectrin {alpha}-chain is four times less stable than neighbouring repeat 16 (R16) in terms of Increment G. The structure of spectrin repeats has mainly been investigated by X-ray crystallography, but the structures of a few repeats, e.g. R16, have also been determined by NMR spectroscopy. Here, we undertook a detailed characterization of the neighbouring R17 by NMR spectroscopy. We assigned most backbone resonances and observed NOE restraints, relaxation values and coupling constants that all indicated that the fold of R17 is highly similar to that of R16, in agreement with previous X-ray analysis of a tandem repeat of the two domains. However, {sup 15}N heteronuclear NMR spectra measured at different temperatures revealed particular features of the R17 domain that might contribute to its lower stability. Conformational exchange appeared to alter the linker connecting R17 to R16 as well as the BC-loop in close proximity. In addition, heat-induced splitting was observed for backbone resonances of a few spatially related residues including V99 of helix C, which in R16 is replaced by the larger hydrophobic tryptophan residue that is relatively conserved among other spectrin repeats. These data support the view that the substitution of tryptophan by valine at this position may contribute to the lower stability of R17.

  18. Standardization in dust emission measurement; Mesure des emissions de poussieres normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Perret, R. [INERIS, 60 - Verneuil-en-Halatte, (France)

    1996-12-31

    The European Standardization Committee (CEN TC 264WG5) is developing a new reference method for measuring particulate emissions, suitable for concentrations inferior to 20 mg/m{sup 3} and especially for concentrations around 5 mg/m{sup 3}; the measuring method should be applicable to waste incinerator effluents and more generally to industrial effluents. Testing protocols and data analysis have been examined and repeatability and reproducibility issues are discussed

  19. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Science.gov (United States)

    Reed, Katharine; Wood, Carly; Barton, Jo; Pretty, Jules N; Cohen, Daniel; Sandercock, Gavin R H

    2013-01-01

    Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run) and self-reported physical activity (PAQ-A) in 11 and 12 year olds (n = 75). Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE) and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74), = 12.2, pself-esteem following exercise but there was no condition by exercise interaction (F (1,74), = 0.13, p = 0.72). There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04) between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55). Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  20. The Pentapeptide Repeat Proteins

    OpenAIRE

    Vetting, Matthew W.; Hegde, Subray S.; Fajardo, J. Eduardo; Fiser, Andras; Roderick, Steven L.; Takiff, Howard E.; Blanchard, John S.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S,T,A,V][D,N][L,F]-[S,T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Myc...

  1. An Examination of Unsteady Airloads on a UH-60A Rotor: Computation Versus Measurement

    Science.gov (United States)

    Biedron, Robert T.; Lee-Rausch, Elizabeth

    2012-01-01

    An unsteady Reynolds-averaged Navier-Stokes solver for unstructured grids is used to simulate the flow over a UH-60A rotor. Traditionally, the computed pressure and shear stresses are integrated on the computational mesh at selected radial stations and compared to measured airloads. However, the corresponding integration of experimental data uses only the pressure contribution, and the set of integration points (pressure taps) is modest compared to the computational mesh resolution. This paper examines the difference between the traditional integration of computed airloads and an integration consistent with that used for the experimental data. In addition, a comparison of chordwise pressure distributions between computation and measurement is made. Examination of this unsteady pressure data provides new opportunities to understand differences between computation and flight measurement.

  2. Microsatellite instability at a tetranucleotide repeat in type I endometrial carcinoma

    Directory of Open Access Journals (Sweden)

    Choi Ho

    2008-12-01

    Full Text Available Abstract Background Microsatellite instability (MSI at tri- or tetranucleotide repeat markers (elevated microsatellite alterations at selected tetranucleotide repeat, EMAST has been recently described. But, the underlying genetic mechanism of EMAST is unclear. This study was to investigate the prevalence of EMAST, in type I endometrial carcinoma, and to determine the correlation between the MSI status and mismatch repair genes (MMR or p53. Methods We examined the 3 mono-, 3 di-, and 6 tetranucleotide repeat markers by PCR in 39 cases of type I endometrial carcinoma and performed the immunohistochemistry of hMSH2, hMLH1, and p53 protein. Results More than two MSI at mono- and dinucleotide repeat markers was noted in 8 cases (MSI-H, 20.5%. MSI, at a tetranucleotide repeat, was detected in 15 cases (EMAST, 38.5%. In remaining 16 cases, any MSI was not observed. (MSS, 42.1%, MSI status was not associated with FIGO stage, grade or depth of invasion. The absence of expression of either one of both hMSH2 or hMLH1 was noted in seven (87.5% of eight MSI-H tumors, one (6.3% of 16 MSS tumors, and five (33.3% of 15 EMAST tumors. (p = 0.010 The expression of p53 protein was found in one (12.5% of eight MSI-H tumors, five (31.3% of 16 MSS tumors, and seven of 15 EMAST tumors. (p = 0.247 Conclusion Our results showed that about 38.5% of type I endometrial carcinomas exhibited EMAST, and that EMAST was rarely associated with alteration of hMSH2 or hMLH1.

  3. Spatial Component Position in Total Hip Arthroplasty. Accuracy and repeatability with a new CT method

    International Nuclear Information System (INIS)

    Olivecrona, H.

    2003-01-01

    Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically

  4. Spatial Component Position in Total Hip Arthroplasty. Accuracy and repeatability with a new CT method

    Energy Technology Data Exchange (ETDEWEB)

    Olivecrona, H. [Soedersjukhuset, Stockholm (Sweden). Dept. of Hand Surgery; Weidenhielm, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Orthopedics; Olivecrona, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Radiology; Noz, M.E. [New York Univ. School of Medicine, NY (United States). Dept. of Radiology; Maguire, G.Q. [Royal Inst. of Tech., Kista (Sweden). Inst. for Microelectronics and Information Technology; Zeleznik, M. P. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Radiation Oncology; Svensson, L. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Mathematics; Jonson, T. [Eskadern Foeretagsutveckling AB, Goeteborg (Sweden)

    2003-03-01

    Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.

  5. Muscle Damage and Metabolic Responses to Repeated-Sprint Running With and Without Deceleration.

    Science.gov (United States)

    Minahan, Clare L; Poke, Daniel P; Morrison, Jaime; Bellinger, Phillip M

    2018-04-04

    Minahan, CL, Poke, DP, Morrison, J, and Bellinger, PM. Muscle damage and metabolic responses to repeated-sprint running with and without deceleration. J Strength Cond Res XX(X): 000-000, 2017-This study aimed to determine whether repeated-sprint running with deceleration aggravates markers of muscle damage or delays the recovery of performance compared with repeated-sprint running without deceleration. Fourteen male team-sport athletes performed 2 randomly ordered testing sessions on a nonmotorized treadmill with one session requiring participants to decelerate (TMd) within 4 seconds before stopping or immediately step to the side of the treadmill belt at the completion of each sprint (TMa). Peak and mean velocities, speed decrement, blood lactate concentrations, and oxygen uptake were monitored during the repeated-sprint running protocols. Countermovement vertical jump (CMJ) performance, perceived muscle soreness, sit-and-reach flexibility, plasma creatine kinase (CK), lactate dehydrogenase (LDH), and myoglobin (Mb) concentrations were quantified immediately before and after and 45 minutes, 24 and 48 hours after repeated-sprint running protocols. Although muscle damage was indicated by increases in CK, LDH, and Mb (p ≤ 0.05) in both groups, there was no significant effect of condition (TMa vs. TMd) on any of the measured performance or physiological variables (p > 0.05). The present study indicated that the removal of deceleration from repeated-sprint running on a nonmotorized treadmill has no effect on metabolism or performance during or after repeated-sprint running or markers of muscle damage.

  6. Magnetic Repeat Station Network on the Baltic Sea — Why So Needed?

    Directory of Open Access Journals (Sweden)

    Welker Elżbieta

    2017-12-01

    Full Text Available The development of navigation systems requires more and more accurate base data. Currently, attention is paid to utilization of geophysical fields — gravitational and magnetic ones — for navigation purposes. The Earth’s magnetic field distribution — both onshore and offshore — is complicated and variable in time. Hence, it is essential to precisely know the secular variations in the area of interest. In the case of Baltic Sea, this involves establishing (re-establishing of a marine network of secular points (repeat stations and regular magnetic measurements of the three independent components of the Earth’s magnetic field. Such measurements require equipment that ensures not only high stability, but also information about sensors’ orientation in relation to geographic north and to the level. This article presents a new project of the Baltic network of repeat stations and gives a solution for the instruments usable for quasi-absolute magnetic measurements.

  7. Test-retest repeatability of myocardial oxidative metabolism and efficiency using standalone dynamic 11C-acetate PET and multimodality approaches in healthy controls.

    Science.gov (United States)

    Hansson, Nils Henrik; Harms, Hendrik Johannes; Kim, Won Yong; Nielsen, Roni; Tolbod, Lars P; Frøkiær, Jørgen; Bouchelouche, Kirsten; Poulsen, Steen Hvitfeldt; Wiggers, Henrik; Parner, Erik Thorlund; Sörensen, Jens

    2018-05-31

    Myocardial efficiency measured by 11 C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11 C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE CMR , MEE Echo , and MEE PET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P PET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m 2  × 10 6 , respectively, P = .45. Repeatability for MEE CMR was superior compared with MEE Echo but did not differ significantly compared with MEE PET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI CMR , WMI Echo , and WMI PET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Non-invasive measurements of MEE using 11 C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.

  8. Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Matricali, Giovanni A; Spaepen, Pieter; Meyer, Christophe; Desloovere, Kaat

    2012-07-01

    Repeatability studies on 3D multi-segment foot models (3DMFMs) have mainly considered healthy participants which contrasts with the widespread application of these models to evaluate foot pathologies. The current study aimed at establishing the repeatability of the 3DMFM described by Leardini et al. in presence of foot deformities. Foot kinematics of eight adult participants were analyzed using a repeated-measures design including two therapists with different levels of experience. The inter-trial variability was higher compared to the kinematics of healthy subjects. Consideration of relative angles resulted in the lowest inter-session variability. The absolute 3D rotations between the Sha-Cal and Cal-Met seem to have the lowest variability in both therapists. A general trend towards higher σ(sess)/σ(trial) ratios was observed when the midfoot was involved. The current study indicates that not only relative 3D rotations and planar angles can be measured consistently in patients, also a number of absolute parameters can be consistently measured serving as basis for the decision making process. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. SeqEntropy: genome-wide assessment of repeats for short read sequencing.

    Directory of Open Access Journals (Sweden)

    Hsueh-Ting Chu

    Full Text Available BACKGROUND: Recent studies on genome assembly from short-read sequencing data reported the limitation of this technology to reconstruct the entire genome even at very high depth coverage. We investigated the limitation from the perspective of information theory to evaluate the effect of repeats on short-read genome assembly using idealized (error-free reads at different lengths. METHODOLOGY/PRINCIPAL FINDINGS: We define a metric H(k to be the entropy of sequencing reads at a read length k and use the relative loss of entropy ΔH(k to measure the impact of repeats for the reconstruction of whole-genome from sequences of length k. In our experiments, we found that entropy loss correlates well with de-novo assembly coverage of a genome, and a score of ΔH(k>1% indicates a severe loss in genome reconstruction fidelity. The minimal read lengths to achieve ΔH(k<1% are different for various organisms and are independent of the genome size. For example, in order to meet the threshold of ΔH(k<1%, a read length of 60 bp is needed for the sequencing of human genome (3.2 10(9 bp and 320 bp for the sequencing of fruit fly (1.8×10(8 bp. We also calculated the ΔH(k scores for 2725 prokaryotic chromosomes and plasmids at several read lengths. Our results indicate that the levels of repeats in different genomes are diverse and the entropy of sequencing reads provides a measurement for the repeat structures. CONCLUSIONS/SIGNIFICANCE: The proposed entropy-based measurement, which can be calculated in seconds to minutes in most cases, provides a rapid quantitative evaluation on the limitation of idealized short-read genome sequencing. Moreover, the calculation can be parallelized to scale up to large euakryotic genomes. This approach may be useful to tune the sequencing parameters to achieve better genome assemblies when a closely related genome is already available.

  10. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  11. Preservice science teachers' experiences with repeated, guided inquiry

    Science.gov (United States)

    Slack, Amy B.

    The purpose of this study was to examine preservice science teachers' experiences with repeated scientific inquiry (SI) activities. The National Science Education Standards (National Research Council, 1996) stress students should understand and possess the abilities to do SI. For students to meet these standards, science teachers must understand and be able to perform SI; however, previous research demonstrated that many teachers have naive understandings in this area. Teacher preparation programs provide an opportunity to facilitate the development of inquiry understandings and abilities. In this study, preservice science teachers had experiences with two inquiry activities that were repeated three times each. The research questions for this study were (a) How do preservice science teachers' describe their experiences with repeated, guided inquiry activities? (b) What are preservice science teachers' understandings and abilities of SI? This study was conducted at a large, urban university in the southeastern United States. The 5 participants had bachelor's degrees in science and were enrolled in a graduate science education methods course. The researcher was one of the course instructors but did not lead the activities. Case study methodology was used. Data was collected from a demographic survey, an open-ended questionnaire with follow-up interviews, the researcher's observations, participants' lab notes, personal interviews, and participants' journals. Data were coded and analyzed through chronological data matrices to identify patterns in participants' experiences. The five domains identified in this study were understandings of SI, abilities to conduct SI, personal feelings about the experience, science content knowledge, and classroom implications. Through analysis of themes identified within each domain, the four conclusions made about these preservice teachers' experiences with SI were that the experience increased their abilities to conduct inquiry

  12. An audit of rejected repeated x-ray films as a quality assurance element in a radiology department.

    Science.gov (United States)

    Eze, K C; Omodia, N; Okegbunam, B; Adewonyi, T; Nzotta, C C

    2008-12-01

    To find out the causes, number, percentage and sizes of rejected radiographic films with a view of adopting measures that will reduce the rate and number of rejected films. Radiology Department of a University Teaching Hospital. Over a two-year period (1st April 2002 to 31st March 2004), the total number of x-ray films utilized for radiographic examinations, rejected films and sizes of rejected films were collected retrospectively from the medical record of radiology department. All the rejected films were viewed by a radiologist and three radiographers for the causes of the rejects which was arrived at by consensus. The data was analysed. A total of 15,095 films were used in the study period and 1,338 films (8.86%) were rejected or wasted. The rate of rejected films varied from 7.69% to 13.82% with average of 8.86%. The greatest cause of film rejects was radiographers' faults 547 (40.88%), followed by equipments faults 255 (19.06%), and patients' faults 250 (18.90%). The highest reject rate (13.82%) was for films used for examination of the spine (15 x 30) cm size. This is followed by 9.92% for skull (18 x 24) cm films and 8.83% for small sized films (24 x 30) cm used for paediatric patients. Of a total of 1,338 rejected films, 1276 (95.37%) additional exposure were done to obtain the basic desired diagnostic information involving 1151 patients; 885 (76.89%) of these patients needed at least one additional hospital visit to take the repeat exposure. Rejected films are not billable; patients receive additional radiation and may even come to hospital in another day for the repeat. Radiographer's work is increased as well as that of the support staff. The waiting room may be congested and waiting time increased. The cost of processing chemical and films are increased, thus if work is quantified in monetary terms, the cost of repeats is high. Rejected-repeated film analysis is cheap, simple, practicable, easy to interpret and an effective indictor of quality assurance

  13. Test–retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects

    International Nuclear Information System (INIS)

    Cutajar, Marica; Clayden, Jonathan D.; Clark, Christopher A.; Gordon, Isky

    2011-01-01

    Purpose: This study assessed test–retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Materials and methods: Seven healthy volunteers (age range, 19–31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR = 730 ms, TE = 73 ms and 2 b-values (0 and 400 s mm −2 ). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Results: Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Conclusion: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable.

  14. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  15. Repeat-Associated Plasticity in the Helicobacter pylori RD Gene Family▿ †

    Science.gov (United States)

    Shak, Joshua R.; Dick, Jonathan J.; Meinersmann, Richard J.; Perez-Perez, Guillermo I.; Blaser, Martin J.

    2009-01-01

    The bacterium Helicobacter pylori is remarkable for its ability to persist in the human stomach for decades without provoking sterilizing immunity. Since repetitive DNA can facilitate adaptive genomic flexibility via increased recombination, insertion, and deletion, we searched the genomes of two H. pylori strains for nucleotide repeats. We discovered a family of genes with extensive repetitive DNA that we have termed the H. pylori RD gene family. Each gene of this family is composed of a conserved 3′ region, a variable mid-region encoding 7 and 11 amino acid repeats, and a 5′ region containing one of two possible alleles. Analysis of five complete genome sequences and PCR genotyping of 42 H. pylori strains revealed extensive variation between strains in the number, location, and arrangement of RD genes. Furthermore, examination of multiple strains isolated from a single subject's stomach revealed intrahost variation in repeat number and composition. Despite prior evidence that the protein products of this gene family are expressed at the bacterial cell surface, enzyme-linked immunosorbent assay and immunoblot studies revealed no consistent seroreactivity to a recombinant RD protein by H. pylori-positive hosts. The pattern of repeats uncovered in the RD gene family appears to reflect slipped-strand mispairing or domain duplication, allowing for redundancy and subsequent diversity in genotype and phenotype. This novel family of hypervariable genes with conserved, repetitive, and allelic domains may represent an important locus for understanding H. pylori persistence in its natural host. PMID:19749042

  16. Intraoperative mapping during repeat awake craniotomy reveals the functional plasticity of adult cortex.

    Science.gov (United States)

    Southwell, Derek G; Hervey-Jumper, Shawn L; Perry, David W; Berger, Mitchel S

    2016-05-01

    OBJECT To avoid iatrogenic injury during the removal of intrinsic cerebral neoplasms such as gliomas, direct electrical stimulation (DES) is used to identify cortical and subcortical white matter pathways critical for language, motor, and sensory function. When a patient undergoes more than 1 brain tumor resection as in the case of tumor recurrence, the use of DES provides an unusual opportunity to examine brain plasticity in the setting of neurological disease. METHODS The authors examined 561 consecutive cases in which patients underwent DES mapping during surgery forglioma resection. "Positive" and "negative" sites-discrete cortical regions where electrical stimulation did (positive) or did not (negative) produce transient sensory, motor, or language disturbance-were identified prior to tumor resection and documented by intraoperative photography for categorization into functional maps. In this group of 561 patients, 18 were identified who underwent repeat surgery in which 1 or more stimulation sites overlapped with those tested during the initial surgery. The authors compared intraoperative sensory, motor, or language mapping results between initial and repeat surgeries, and evaluated the clinical outcomes for these patients. RESULTS A total of 117 sites were tested for sensory (7 sites, 6.0%), motor (9 sites, 7.7%), or language (101 sites, 86.3%) function during both initial and repeat surgeries. The mean interval between surgical procedures was 4.1 years. During initial surgeries, 95 (81.2%) of 117 sites were found to be negative and 22 (18.8%) of 117 sites were found to be positive. During repeat surgeries, 103 (88.0%) of 117 sites were negative and 14 (12.0%) of 117 were positive. Of the 95 sites that were negative at the initial surgery, 94 (98.9%) were also negative at the repeat surgery, while 1 (1.1%) site was found to be positive. Of the 22 sites that were initially positive, 13 (59.1%) remained positive at repeat surgery, while 9 (40.9%) had become

  17. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    Science.gov (United States)

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  18. Thermal, cardiac and adrenergic responses to repeated local cooling.

    Science.gov (United States)

    Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P

    2006-01-01

    The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.

  19. THE EFFECTS OF SINGLE VERSUS REPEATED PLYOMETRICS ON LANDING BIOMECHANICS AND JUMPING PERFORMANCE IN MEN

    Directory of Open Access Journals (Sweden)

    H. Makaruk

    2014-07-01

    Full Text Available The aim of this study was to examine the chronic effects of single and repeated jumps training on vertical landing force (VGRF and jump height in untrained men. The VGRF and jump height were compared after a six-week plyometric training programme containing single and repeated jumps, together with two additional parameters: landing time (LT and range of the knee flexion during landing (KF. Thirty-six untrained physical education students with a plyometric training background were randomly assigned to a single jump group (SJG, n =12, repeated jumps group (RJG, n =12, and control group (CON, n =12. The SJG performed only single jumps, the RJG executed repeated (consecutive jumps, whereas the CON did not perform any exercises at all. A countermovement jump (CMJ, repeated countermovement jumps (RCMJ, and a drop jump (DJ were tested before and after the training. Only the RJG showed a significantly reduced VGRF (p<0.05 in all tests. Both plyometric groups significantly improved (p<0.05 their jump height in all tests. The LT was significantly greater in the RJG, compared to the SJG, in all tests. The KF was also significantly (p<0.05 greater in the RJG than in the SJG for CMJ and RCMJ. The results suggest that repeated jumps are beneficial for simultaneous landing force reduction and jumping performance enhancement.

  20. A high stability and repeatability electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-12-01

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  1. Repeated E-Book Reading and Its Contribution to Learning New Words among Kindergartners

    Science.gov (United States)

    Korat, Ofra; Kozlov-Peretz, Olla; Segal-Drori, Ora

    2017-01-01

    The contribution of repeated e-book reading with and without word explanation support and its effect on receptive and expressive word learning among preschoolers was examined. Seventy-eight kindergartners were randomly divided into an experimental and a control group. The experimental group received two individual reading sessions of an e-book…

  2. Impact of depressive symptoms, self-esteem and neuroticism on trajectories of overgeneral autobiographical memory over repeated trials.

    Science.gov (United States)

    Kashdan, Todd B; Roberts, John E; Carlos, Erica L

    2006-04-01

    The present study examined trajectories of change in the frequency of overgeneral autobiographical memory (OGM) over the course of repeated trials, and tested whether particular dimensions of depressive symptomatology (somatic and cognitive-affective distress), self-esteem, and neuroticism account for individual differences in these trajectories. Given that depression is associated with impairments in effortful processing, we predicted that over repeated trials depression would be associated with increasingly OGM. Generalised Linear Mixed Models with Penalised Quasi-Likelihood demonstrated significant linear and quadratic trends in OGM over repeated trials, and somatic distress and self-esteem moderated these slopes. The form of these interactions suggested that somatic distress and low self-esteem primarily contribute to OGM during the second half of the trial sequence. The present findings demonstrate the value of a novel analytical approach to OGM that estimates individual trajectories of change over repeated trials.

  3. Ubiquitous expression of CUG or CAG trinucleotide repeat RNA causes common morphological defects in a Drosophila model of RNA-mediated pathology.

    Directory of Open Access Journals (Sweden)

    Kynan T Lawlor

    Full Text Available Expanded DNA repeat sequences are known to cause over 20 diseases, including Huntington's disease, several types of spinocerebellar ataxia and myotonic dystrophy type 1 and 2. A shared genetic basis, and overlapping clinical features for some of these diseases, indicate that common pathways may contribute to pathology. Multiple mechanisms, mediated by both expanded homopolymeric proteins and expanded repeat RNA, have been identified by the use of model systems, that may account for shared pathology. The use of such animal models enables identification of distinct pathways and their 'molecular hallmarks' that can be used to determine the contribution of each pathway in human pathology. Here we characterise a tergite disruption phenotype in adult flies, caused by ubiquitous expression of either untranslated CUG or CAG expanded repeat RNA. Using the tergite phenotype as a quantitative trait we define a new genetic system in which to examine 'hairpin' repeat RNA-mediated cellular perturbation. Further experiments use this system to examine whether pathways involving Muscleblind sequestration or Dicer processing, which have been shown to mediate repeat RNA-mediated pathology in other model systems, contribute to cellular perturbation in this model.

  4. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  5. How do repeat suicide attempters differ from first timers? An exploratory record based analysis

    Directory of Open Access Journals (Sweden)

    Vikas Menon

    2016-01-01

    Full Text Available Background: Evidence indicates that repeat suicide attempters, as a group, may differ from 1st time attempters. The identification of repeat attempters is a powerful but underutilized clinical variable. Aims: In this research, we aimed to compare individuals with lifetime histories of multiple attempts with 1st time attempters to identify factors predictive of repeat attempts. Setting and Design: This was a retrospective record based study carried out at a teaching cum Tertiary Care Hospital in South India. Methods: Relevant data was extracted from the clinical records of 1st time attempters (n = 362 and repeat attempters (n = 61 presenting to a single Tertiary Care Center over a 4½ year period. They were compared on various sociodemographic and clinical parameters. The clinical measures included Presumptive Stressful Life Events Scale, Beck Hopelessness Scale, Coping Strategies Inventory – Short Form, and the Global Assessment of Functioning Scale. Statistical Analysis Used: First time attempters and repeaters were compared using appropriate inferential statistics. Logistic regression was used to identify independent predictors of repeat attempts. Results: The two groups did not significantly differ on sociodemographic characteristics. Repeat attempters were more likely to have given prior hints about their act (χ2 = 4.500, P = 0.034. In the final regression model, beck hopelessness score emerged as a significant predictor of repeat suicide attempts (odds ratio = 1.064, P = 0.020. Conclusion: Among suicide attempters presenting to the hospital, the presence of hopelessness is a predictor of repeat suicide attempts, independent of clinical depression. This highlights the importance of considering hopelessness in the assessment of suicidality with a view to minimize the risk of future attempts.

  6. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  7. Hybrid FRC under repeated loading

    International Nuclear Information System (INIS)

    Komlos, K.; Babal, B.; Nuernbergerova, T.

    1993-01-01

    Fibre reinforced concretes (FRC) containing several volume fractions in different ratios of two types of fibres - polypropylene and steel, were tested under repeated loading. Mechanical properties of specimens - cubes 150/150/150 mm (for compressive strength), prisms 100/100/400 (for flexural strength), short cylinders 150/60 mm (for impact strength) have been experimentally investigated before and after cyclic loading at the age of 28 days curing time. Mix proportions were designed after DIN 1045 with max. aggregate size 8 mm and grading curve B 8. Portland Cement PC 400 in the amount of 450 kg. m -3 was applied and W/C ratio 0.55. Workability of mixes was measured by Vebe method and regulated by plasticizing admixture Ligoplast Na. Maximum hybrid fibre volume fraction (polypropylene + steel) was 1.0%. Dynamic forces generated in Schenck testing machine with frequency 16 Hz had sinusoidal wave form varying between 0.7 and 0.1 of static mechanical characteristics. The number of cycles in all tests was 10 5 . The residual MOR at static four point bending test and working diagram force-deflection was carried out as well. The impact properties after repeated loading in compression were tested by means of falling weight test. Relationships between composition of fibre composites with different combination of polypropylene (0.2, 0.3, 0.5% by volume) and steel (0.5, 0.7, and 0.8% by volume) fibre content were obtained and technological properties of mixes as well. (author)

  8. Control of coercive field in lithium niobate crystals with repeated polarization reversal

    International Nuclear Information System (INIS)

    Ro, Jung Hoon; Jeong, Doun; Park, Taeyong; Kim, Chulhan; Kwon, Soon-Bok; Cha, Myoungsik; Choi, Byeong Cheol; Yu, Nanei; Kurimura, Sunao; Jeon, Gyerok

    2005-01-01

    In this study, the amount of decrease in coercive field of congruent lithium niobate during repeated poling and back-poling was measured. The polarization is reversed in 300 ms and then back-poled during the rest period. The coercive field can be decreased around 1 kV/mm with a repeated poling interval of 5 s. As the interval prolonged, the poling field decrease became smaller, and a stretched exponential function is suggested for the experimental fitting resulting in a set of meaningful parameters. These values are essential for the design of high quality domain engineering

  9. Understanding Mixed Emotions: Paradigms and Measures

    Science.gov (United States)

    Kreibig, Sylvia D.; Gross, James J.

    2017-01-01

    In this review, we examine the paradigms and measures available for experimentally studying mixed emotions in the laboratory. For eliciting mixed emotions, we describe a mixed emotions film library that allows for the repeated elicitation of a specific homogeneous mixed emotional state and appropriately matched pure positive, pure negative, and neutral emotional states. For assessing mixed emotions, we consider subjective and objective measures that fall into univariate, bivariate, and multivariate measurement categories. As paradigms and measures for objectively studying mixed emotions are still in their early stages, we conclude by outlining future directions that focus on the reliability, temporal dynamics, and response coherence of mixed emotions paradigms and measures. This research will build a strong foundation for future studies and significantly advance our understanding of mixed emotions. PMID:28804752

  10. Rethinking the Measurement of Place Brands

    DEFF Research Database (Denmark)

    Zenker, Sebastian; Braun, Erik

    2015-01-01

    in the form of free brand associations of target customers with qualitative methods; in the form of attributes with quantitative methods like standardized questionnaires; and with mixed methods that combine qualitative research with quantitative methods. Two mixed methods, namely the network analysis......Place brand managers often disregard the complexity of place brands, as do their counterparts in the academic arena: they repeatedly use simple explorative descriptions of certain place brands, rather than a precise measurement. Thus, this chapter aims to identify and discuss measurement approaches...... that could prove useful in place branding. Therefore, we will define the brand and examine various options regarding what to measure in place branding. Finally, we will discuss the different approaches of brand measurement for their use in place branding, namely the approaches to measuring the brand...

  11. Characterization of the repeat expansion size in C9orf72 in amyotrophic lateral sclerosis and frontotemporal dementia.

    Science.gov (United States)

    Dols-Icardo, Oriol; García-Redondo, Alberto; Rojas-García, Ricard; Sánchez-Valle, Raquel; Noguera, Aina; Gómez-Tortosa, Estrella; Pastor, Pau; Hernández, Isabel; Esteban-Pérez, Jesús; Suárez-Calvet, Marc; Antón-Aguirre, Sofía; Amer, Guillermo; Ortega-Cubero, Sara; Blesa, Rafael; Fortea, Juan; Alcolea, Daniel; Capdevila, Aura; Antonell, Anna; Lladó, Albert; Muñoz-Blanco, José Luís; Mora, Jesús S; Galán-Dávila, Lucía; Rodríguez De Rivera, Francisco Javier; Lleó, Alberto; Clarimón, Jordi

    2014-02-01

    Hexanucleotide repeat expansions within the C9orf72 gene are the most important genetic cause of amyotrophic lateral sclerosis (ALS) and frontotemporal dementia (FTD). The difficulty of developing a precise method to determine the expansion size has hampered the study of possible correlations between the hexanucleotide repeat number and clinical phenotype. Here we characterize, through a new non-radioactive Southern blot protocol, the expansion size range in a series of 38 ALS and 22 FTD heterozygous carriers of >30 copies of the repeat. Maximum, median and modal hexanucleotide repeat number were higher in ALS patients than in FTD patients (P< 0.05 in all comparisons). A higher median number of repeats correlated with a bigger range of repeat sizes (Spearman's ρ = 0.743, P = 1.05 × 10(-11)). We did not find any correlation between age of onset or disease duration with the repeat size in neither ALS nor FTD mutation carriers. Clinical presentation (bulbar or spinal) in ALS patients did not correlate either with the repeat length. We finally analyzed two families with affected and unaffected repeat expansion carriers, compared the size of the repeat expansion between two monozygotic (MZ) twins (one affected of ALS and the other unaffected), and examined the expansion size in two different tissues (cerebellum and peripheral blood) belonging to the same FTD patient. The results suggested that the length of the C9orf72 repeat varies between family members, including MZ twins, and among different tissues from the same individual.

  12. An Examination of Alternative Poverty Measures for the Wisconsin Equalization Aid Formula.

    Science.gov (United States)

    Cibulka, James G.

    1986-01-01

    Wisconsin's guaranteed tax base equalization formula has no direct adjustment for the additional costs of educating poverty level pupils. This paper establishes the need for an adjustment and examines three measures (based on varying poverty definitions) to determine which provides the most equitable funding formula for educating poor children. (9…

  13. Digital repeat analysis; setup and operation.

    Science.gov (United States)

    Nol, J; Isouard, G; Mirecki, J

    2006-06-01

    Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.

  14. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    Science.gov (United States)

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  15. Apraxia of Speech: Perceptual Analysis of Trisyllabic Word Productions across Repeated Sampling Occasions

    Science.gov (United States)

    Mauszycki, Shannon C.; Wambaugh, Julie L.; Cameron, Rosalea M.

    2012-01-01

    Purpose: Early apraxia of speech (AOS) research has characterized errors as being variable, resulting in a number of different error types being produced on repeated productions of the same stimuli. Conversely, recent research has uncovered greater consistency in errors, but there are limited data examining sound errors over time (more than one…

  16. The Student Volunteer Army: a 'repeat emergent' emergency response organisation.

    Science.gov (United States)

    Carlton, Sally; Mills, Colleen E

    2017-10-01

    This paper seeks to contribute to understanding of the factors associated with an effective emergent emergency response organisation and to provide new insights into this understudied area. It examines, through an analysis of a range of textual resources, the emergence and re-emergence of the Student Volunteer Army (SVA) during the devastating earthquakes in Canterbury, New Zealand, in 2010-11. This evaluation is conducted in relation to the four key features of an effective emergency response organisation: adaptability; direction; leadership; and communication. In addition, the paper aims to further understanding of 'emergency entrepreneurship' and thus of the values and strategies that underpin social entrepreneur organisations in times of normalcy. The paper concludes that the unique position of the SVA as a 'repeat emergent' emergency response organisation enabled it to innovate continually and to improve repeatedly its systems, relationships, and image, such that it exhibited features common to emergent and established emergency response organisations. © 2017 The Author(s). Disasters © Overseas Development Institute, 2017.

  17. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2018-01-01

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Trial of Repeated Analgesia with Kangaroo Mother Care (TRAKC Trial)

    Science.gov (United States)

    2013-01-01

    Background Skin-to-skin contact (SSC) between mother and infant, commonly referred to as Kangaroo Mother Care (KMC), is recommended as an intervention for procedural pain. Evidence demonstrates its consistent efficacy in reducing pain for a single painful procedure. The purpose of this study is to examine the sustained efficacy of KMC, provided during all routine painful procedures for the duration of Neonatal Intensive Care Unit (NICU) hospitalization, in diminishing behavioral pain response in preterm neonates. The efficacy of KMC alone will be compared to standard care of 24% oral sucrose, as well as the combination of KMC and 24% oral sucrose. Methods/design Infants admitted to the NICU who are less than 36 6/7 weeks gestational age (according to early ultrasound), that are stable enough to be held in KMC, will be considered eligible (N = 258). Using a single-blinded randomized parallel group design, participants will be assigned to one of three possible interventions: 1) KMC, 2) combined KMC and sucrose, and 3) sucrose alone, when they undergo any routine painful procedure (heel lance, venipuncture, intravenous, oro/nasogastric insertion). The primary outcome is infant’s pain intensity, which will be assessed using the Premature Infant Pain Profile (PIPP). The secondary outcome will be maturity of neurobehavioral functioning, as measured by the Neurobehavioral Assessment of the Preterm Infant (NAPI). Gestational age, cumulative exposure to KMC provided during non-pain contexts, and maternal cortisol levels will be considered in the analysis. Clinical feasibility will be accounted for from nurse and maternal questionnaires. Discussion This will be the first study to examine the repeated use of KMC for managing procedural pain in preterm neonates. It is also the first to compare KMC to sucrose, or the interventions in combination, across time. Based on the theoretical framework of the brain opioid theory of attachment, it is expected that KMC will be a

  19. Opening Doors to Recovery: Recidivism and Recovery Among Persons With Serious Mental Illnesses and Repeated Hospitalizations.

    Science.gov (United States)

    Compton, Michael T; Kelley, Mary E; Pope, Alicia; Smith, Kelly; Broussard, Beth; Reed, Thomas A; DiPolito, June A; Druss, Benjamin G; Li, Charles; Lott Haynes, Nora

    2016-02-01

    Repeated hospitalizations and arrests or incarcerations diminish the ability of individuals with serious mental illnesses to pursue recovery. Community mental health systems need new models to address recidivism as well as service fragmentation, lack of engagement by local stakeholders, and poor communication between mental health providers and the police. This study examined the initial effects on institutional recidivism and measures of recovery among persons enrolled in Opening Doors to Recovery, an intensive, team-based community support program for persons with mental illness and a history of inpatient psychiatric recidivism. A randomized controlled trial of the model is underway. The number of hospitalizations, days hospitalized, and arrests (all from state administrative sources) in the year before enrollment and during the first 12 months of enrollment in the program were compared. Longitudinal trajectories of recovery-using three self-report and five clinician-rated measures-were examined. Analyses accounted for baseline symptom severity and intensity of involvement in the program. One hundred participants were enrolled, and 72 were included in the analyses. Hospitalizations decreased, from 1.9±1.6 to .6±.9 (precovery measures, and trajectories of improvement were apparent across the entire follow-up period. Opening Doors to Recovery holds promise as a new service approach for reducing hospital recidivism and promoting recovery in community mental health systems and is deserving of further controlled testing.

  20. Analysis of the Effect of Radio Frequency Interference on Repeat Track Airborne InSAR System

    Directory of Open Access Journals (Sweden)

    Ding Bin

    2012-03-01

    Full Text Available The SAR system operating at low frequency is susceptible to Radio Frequency Interference (RFI from television station, radio station, and some other civil electronic facilities. The presence of RFI degrades the SAR image quality, and obscures the targets in the scene. Furthermore, RFI can cause interferometric phase error in repeat track InSAR system. In order to analyze the effect of RFI on interferometric phase of InSAR, real measured RFI signal are added on cone simulated SAR echoes. The imaging and interferometric processing results of both the RFI-contaminated and raw data are given. The effect of real measured RFI signal on repeat track InSAR system is analyzed. Finally, the imaging and interferometric processing results of both with and without RFI suppressed of the P band airborne repeat track InSAR real data are presented, which demonstrates the efficiency of the RFI suppression method in terms of decreasing the interferometric phase errors caused by RFI.

  1. Genus-specific protein binding to the large clusters of DNA repeats (short regularly spaced repeats) present in Sulfolobus genomes

    DEFF Research Database (Denmark)

    Peng, Xu; Brügger, Kim; Shen, Biao

    2003-01-01

    terminally modified and corresponds to SSO454, an open reading frame of previously unassigned function. It binds specifically to DNA fragments carrying double and single repeat sequences, binding on one side of the repeat structure, and producing an opening of the opposite side of the DNA structure. It also...... recognizes both main families of repeat sequences in S. solfataricus. The recombinant protein, expressed in Escherichia coli, showed the same binding properties to the SRSR repeat as the native one. The SSO454 protein exhibits a tripartite internal repeat structure which yields a good sequence match...... with a helix-turn-helix DNA-binding motif. Although this putative motif is shared by other archaeal proteins, orthologs of SSO454 were only detected in species within the Sulfolobus genus and in the closely related Acidianus genus. We infer that the genus-specific protein induces an opening of the structure...

  2. Emotional stability, anxiety, and natural killer activity under examination stress.

    Science.gov (United States)

    Borella, P; Bargellini, A; Rovesti, S; Pinelli, M; Vivoli, R; Solfrini, V; Vivoli, G

    1999-08-01

    This study was performed to evaluate the relation between a stable personality trait, a mood state and immune response to an examination stress. A self-reported measure of emotional stability (BFQ-ES scale) was obtained in a sample (n = 39) randomly selected from 277 cadets; this personality trait was also investigated by completing a neuroticism scale (Eysenck personality inventory) and a trait-anxiety scale (STAI). Natural killer (NK) cell activity was measured at baseline, long before the examination time and the examination day. The state-anxiety scale evaluated the response to the stressful stimulus. Taking subjects all together, the academic task did not result in significant modification over baseline in NK cell activity. Subjects were then divided into three groups based on emotional stability and state-anxiety scores: high emotional stability/low anxiety, medium, and low emotional stability/high anxiety. Examination stress induced significant increases in NK cell activity in the high emotional stability/low anxiety group, no effect in the medium group, and significant decreases in the low emotional stability/high anxiety group. The repeated-measure ANOVA revealed a significant interaction of group x period (baseline vs. examination) for both lytic units and percent cytolysis. The results did not change after introducing coffee and smoking habits as covariates. Our findings suggest that the state-anxiety acts in concert with a stable personality trait to modulate NK response in healthy subjects exposed to a psychological naturalistic stress. The relation between anxiety and poor immune control has been already described, whereas the ability of emotional stability to associate with an immunoenhancement has not yet reported. The peculiarity of our population, a very homogeneous and healthy group for life style and habits, can have highlighted the role of emotional stability, and may account for the difference with other studies.

  3. Coexistence of 3G repeaters with LTE base stations.

    Science.gov (United States)

    Yeo, Woon-Young; Lee, Sang-Min; Hwang, Gyung-Ho; Kim, Jae-Hoon

    2013-01-01

    Repeaters have been an attractive solution for mobile operators to upgrade their wireless networks at low cost and to extend network coverage effectively. Since the first LTE commercial deployment in 2009, many mobile operators have launched LTE networks by upgrading their 3G and legacy networks. Because all 3G frequency bands are shared with the frequency bands for LTE deployment and 3G mobile operators have an enormous number of repeaters, reusing 3G repeaters in LTE networks is definitely a practical and cost-efficient solution. However, 3G repeaters usually do not support spatial multiplexing with multiple antennas, and thus it is difficult to reuse them directly in LTE networks. In order to support spatial multiplexing of LTE, the role of 3G repeaters should be replaced with small LTE base stations or MIMO-capable repeaters. In this paper, a repeater network is proposed to reuse 3G repeaters in LTE deployment while still supporting multilayer transmission of LTE. Interestingly, the proposed network has a higher cluster throughput than an LTE network with MIMO-capable repeaters.

  4. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan

    2010-12-15

    SIGMOD 2008 was the first database conference that offered to test submitters\\' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  5. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan; Manolescu, Ioana; Afanasiev, Loredana; Feng, Jieling; Gou, G.; Hadjieleftheriou, Marios; Harizopoulos, Stavros; Kalnis, Panos; Karanasos, Konstantinos; Laurent, Dominique; Lupu, M.; Onose, N.; Ré , C.; Sans, Virginie; Senellart, Pierre; Wu, T.; Shasha, Dennis E.

    2010-01-01

    SIGMOD 2008 was the first database conference that offered to test submitters' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  6. Firefighting and mental health: Experiences of repeated exposure to trauma.

    Science.gov (United States)

    Jahnke, Sara A; Poston, Walker S Carlos; Haddock, Christopher K; Murphy, Beth

    2016-02-15

    Firefighters must be ready to respond to a broad range of emergencies every duty day. In the course of many of these emergencies, firefighters witness events which have the potential to induce emotional trauma, such as badly injured people, deceased children, and individuals who are highly distraught. Previous research suggests that repeated exposure to these traumas (RET) may have negative impacts on the emotional and mental health of fire service personnel. Research on the mental health of firefighters has been limited to small surveys reporting the prevalence of specific mental health problems such as depression and post-traumatic stress disorder among firefighters. Despite the likelihood that RET leads to negative outcomes in firefighters, data is lacking on how exposure impacts fire service personnel. The current study examines the experiences of firefighters related to RET. Using formative research methods, we examined the beliefs and experiences of firefighters and administrators from across the United States regarding the impact of RET on firefighter health. Study findings highlight the cumulative psychological toll of repeated exposure to traumatic events including desensitization, flashbacks, and irritability. Results of the current study suggest that RET is a significant concern for emergency responders that warrants additional research and attention. It is likely that the long term consequences of RET are closely intertwined with other mental health outcomes and general well-being of this important occupational group.

  7. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  8. FRB 121102: A Starquake-induced Repeater?

    Science.gov (United States)

    Wang, Weiyang; Luo, Rui; Yue, Han; Chen, Xuelei; Lee, Kejia; Xu, Renxin

    2018-01-01

    Since its initial discovery, the fast radio burst (FRB) FRB 121102 has been found to be repeating with millisecond-duration pulses. Very recently, 14 new bursts were detected by the Green Bank Telescope during its continuous monitoring observations. In this paper, we show that the burst energy distribution has a power-law form which is very similar to the Gutenberg–Richter law of earthquakes. In addition, the distribution of burst waiting time can be described as a Poissonian or Gaussian distribution, which is consistent with earthquakes, while the aftershock sequence exhibits some local correlations. These findings suggest that the repeating FRB pulses may originate from the starquakes of a pulsar. Noting that the soft gamma-ray repeaters (SGRs) also exhibit such distributions, the FRB could be powered by some starquake mechanisms associated with the SGRs, including the crustal activity of a magnetar or solidification-induced stress of a newborn strangeon star. These conjectures could be tested with more repeating samples.

  9. The repeatability and reproducibility of the BioRID IIg in a repeatable laboratory seat based on a production car seat.

    Science.gov (United States)

    Hynd, David; Depinet, Paul; Lorenz, Bernd

    2013-01-01

    The United Nations Economic Commission for Europe Informal Group on GTR No. 7 Phase 2 are working to define a build level for the BioRID II rear impact (whiplash) crash test dummy that ensures repeatable and reproducible performance in a test procedure that has been proposed for future legislation. This includes the specification of dummy hardware, as well as the development of comprehensive certification procedures for the dummy. This study evaluated whether the dummy build level and certification procedures deliver the desired level of repeatability and reproducibility. A custom-designed laboratory seat was made using the seat base, back, and head restraint from a production car seat to ensure a representative interface with the dummy. The seat back was reinforced for use in multiple tests and the recliner mechanism was replaced by an external spring-damper mechanism. A total of 65 tests were performed with 6 BioRID IIg dummies using the draft GTR No.7 sled pulse and seating procedure. All dummies were subject to the build, maintenance, and certification procedures defined by the Informal Group. The test condition was highly repeatable, with a very repeatable pulse, a well-controlled seat back response, and minimal observed degradation of seat foams. The results showed qualitatively reasonable repeatability and reproducibility for the upper torso and head accelerations, as well as for T1 Fx and upper neck Fx . However, reproducibility was not acceptable for T1 and upper neck Fz or for T1 and upper neck My . The Informal Group has not selected injury or seat assessment criteria for use with BioRID II, so it is not known whether these channels would be used in the regulation. However, the ramping-up behavior of the dummy showed poor reproducibility, which would be expected to affect the reproducibility of dummy measurements in general. Pelvis and spine characteristics were found to significantly influence the dummy measurements for which poor reproducibility was

  10. Interactions between cannabidiol and Δ9-THC following acute and repeated dosing: Rebound hyperactivity, sensorimotor gating and epigenetic and neuroadaptive changes in the mesolimbic pathway.

    Science.gov (United States)

    Todd, Stephanie M; Zhou, Cilla; Clarke, David J; Chohan, Tariq W; Bahceci, Dilara; Arnold, Jonathon C

    2017-02-01

    The evidence base for the use of medical cannabis preparations containing specific ratios of cannabidiol (CBD) and Δ 9 -tetrahydrocannabinol (THC) is limited. While there is abundant data on acute interactions between CBD and THC, few studies have assessed the impact of their repeated co-administration. We previously reported that CBD inhibited or potentiated the acute effects of THC dependent on the measure being examined at a 1:1 CBD:THC dose ratio. Further, CBD decreased THC effects on brain regions involved in memory, anxiety and body temperature regulation. Here we extend on these finding by examining over 15 days of treatment whether CBD modulated the repeated effects of THC on behaviour and neuroadaption markers in the mesolimbic dopamine pathway. After acute locomotor suppression, repeated THC caused rebound locomotor hyperactivity that was modestly inhibited by CBD. CBD also slightly reduced the acute effects of THC on sensorimotor gating. These subtle effects were found at a 1:1 CBD:THC dose ratio but were not accentuated by a 5:1 dose ratio. CBD did not alter the trajectory of enduring THC-induced anxiety nor tolerance to the pharmacological effects of THC. There was no evidence of CBD potentiating the behavioural effects of THC. However we demonstrated for the first time that repeated co-administration of CBD and THC increased histone 3 acetylation (H3K9/14ac) in the VTA and ΔFosB expression in the nucleus accumbens. These changes suggest that while CBD may have protective effects acutely, its long-term molecular actions on the brain are more complex and may be supradditive. Copyright © 2016 Elsevier B.V. and ECNP. All rights reserved.

  11. Multielemental segregation analysis of the thallium bromide impurities purified by repeated Bridgman technique

    International Nuclear Information System (INIS)

    Santos, Robinson A. dos; Hamada, Margarida M.; Costa, Fabio E. da; Gennari, Roseli F.; Martins, Joao F.T.; Marcondes, Renata M.; Mesquita, Carlos H. de

    2011-01-01

    TlBr crystals were purified and grown by the repeated Bridgman method from two commercial TlBr salts and characterized to be used as radiation detectors. To evaluate the purification efficiency, measurements of the impurity concentration were made after each growth, analyzing the trace impurities by inductively coupled plasma mass spectroscopy (ICP-MS). A significant decrease of the impurity concentration resulting from the purification number was observed. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out. The radiation response depended on the crystal purity. The repeated Bridgman technique improved the TlBr crystal quality used as a radiation detector. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growth. (author)

  12. A high stability and repeatability electrochemical scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Zhigang; Wang, Jihao; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-12-15

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO{sub 4}{sup 2−} image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  13. On the crustal bias of repeat stations in Romania

    Directory of Open Access Journals (Sweden)

    Venera Dobrica

    2013-03-01

    Full Text Available A magnetic induction model has been applied to recordings obtained in 2010 during the field campaigns for geomagnetic measurements at the 26 repeat stations of the Romanian secular variation network. The model is based on the observation that a variable external magnetic field induces a response of the Earth's interior not only by electromagnetic induction, but also by magnetic induction in the magnetic rocks above the Curie temperature. The model computes coefficients of a linear relationship between recorded values of a certain geomagnetic element (X, Y, Z, or F at the repeat station and recorded X, Y, Z values at a reference station (in this case, SUA observatory. Coefficients depend on magnetic permeabilities of rocks beneath the station and stand as a proxy for the anomaly bias characterizing the site. Maps of the lateral variation of this type of information were obtained and discussed.

  14. Measurement Invariance in Mentoring Research: A Cross-Cultural Examination across Taiwan and the U.S.

    Science.gov (United States)

    Hu, Changya; Pellegrini, Ekin K.; Scandura, Terri A.

    2011-01-01

    Workplace mentoring in the international context is an emerging research area with significant potential for global integration. However, although measurement equivalence is a prerequisite for examining cross-cultural differences, this assumption has yet to be examined in mentoring research. This study contributes to the mentoring literature by…

  15. Repeatability and interobserver reproducibility of Artemis-2 high-frequency ultrasound in determination of human corneal thickness

    Directory of Open Access Journals (Sweden)

    Ogbuehi KC

    2012-05-01

    Full Text Available Kelechi C Ogbuehi, Uchechukwu L OsuagwuOutpatient Clinic, Department of Optometry, King Saud University, Riyadh, Kingdom of Saudi ArabiaBackground: The purpose of this study was to assess the repeatability and limits of agreement of corneal thickness values measured by a high-frequency ultrasound (Artemis-2, hand-held ultrasound pachymeter (DGH-500 and a specular microscope (SP-3000P.Methods: Central corneal thickness (CCT was analyzed in this prospective randomized study that included 32 patients (18 men and 14 women aged 21–24 years. Measurements were obtained in two sessions, one week apart, by two examiners with three devices in a randomized order. Nine measurements were taken (three with each device on one randomly selected eye of each patient in each measurement session. The coefficient of repeatability and interobserver reproducibility for the values of each method were calculated. The limits of agreement between techniques were also evaluated.Results: There were no significant differences in CCT values between sessions for each of the three devices (P > 0.05. The repeatability coefficients for the Artemis-2 (±8 µm/±9 µm were superior to those of the SP-3000P (±9 µm/±11 µm and DGH 500 (±12 µm/±12 µm in session 1/session 2 respectively, while the interobserver reproducibility index (differences between session 1 and session 2 was superior for the SP-3000P (±17 µm with respect to DHG-500 (±29 µm and the Artemis-2 (±31 µm. In session 1 and session 2, the limits of agreement between the techniques were 35 µm to -31 µm and 34 to -20 µm, respectively, for DGH-500 versus Artemis-2, 73 µm to 3 µm and 60 µm to 9 µm for Artemis-2 versus SP-3000P, and 58 µm to 22 µm and 72 µm to 10 µm for DGH-500 versus SP-3000P comparisons. The DGH-500 and Artemis-2 gave similar values (P > 0.05 in both sessions, but both (Artemis-2 and DGH-500 values were significantly greater than that of the SP-3000P (P < 0.05 in both sessions

  16. Secondhand tobacco smoke exposure and heart rate variability and inflammation among non-smoking construction workers: a repeated measures study.

    Science.gov (United States)

    Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M

    2013-10-02

    Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated

  17. PET functional volume delineation: a robustness and repeatability study

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Cheze-le Rest, Catherine; Albarghach, Nidal; Pradier, Olivier; Visvikis, Dimitris

    2011-01-01

    Current state-of-the-art algorithms for functional uptake volume segmentation in PET imaging consist of threshold-based approaches, whose parameters often require specific optimization for a given scanner and associated reconstruction algorithms. Different advanced image segmentation approaches previously proposed and extensively validated, such as among others fuzzy C-means (FCM) clustering, or fuzzy locally adaptive bayesian (FLAB) algorithm have the potential to improve the robustness of functional uptake volume measurements. The objective of this study was to investigate robustness and repeatability with respect to various scanner models, reconstruction algorithms and acquisition conditions. Robustness was evaluated using a series of IEC phantom acquisitions carried out on different PET/CT scanners (Philips Gemini and Gemini Time-of-Flight, Siemens Biograph and GE Discovery LS) with their associated reconstruction algorithms (RAMLA, TF MLEM, OSEM). A range of acquisition parameters (contrast, duration) and reconstruction parameters (voxel size) were considered for each scanner model, and the repeatability of each method was evaluated on simulated and clinical tumours and compared to manual delineation. For all the scanner models, acquisition parameters and reconstruction algorithms considered, the FLAB algorithm demonstrated higher robustness in delineation of the spheres with low mean errors (10%) and variability (5%), with respect to threshold-based methodologies and FCM. The repeatability provided by all segmentation algorithms considered was very high with a negligible variability of <5% in comparison to that associated with manual delineation (5-35%). The use of advanced image segmentation algorithms may not only allow high accuracy as previously demonstrated, but also provide a robust and repeatable tool to aid physicians as an initial guess in determining functional volumes in PET. (orig.)

  18. Repeat Syphilis Among Men Who Have Sex With Men in California, 2002–2006: Implications for Syphilis Elimination Efforts

    Science.gov (United States)

    Chew Ng, Rilene A.; Katz, Kenneth A.; Bernstein, Kyle T.; Samuel, Michael C.; Kerndt, Peter R.; Bolan, Gail

    2012-01-01

    Objectives. We examined rates of and risk factors for repeat syphilis infection among men who have sex with men (MSM) in California. Methods. We analyzed 2002 to 2006 California syphilis surveillance system data. Results. During the study period, a mean of 5.9% (range: 4.9%–7.1% per year) of MSM had a repeat primary or secondary (PS) syphilis infection within 2 years of an initial infection. There was no significant increase in the annual proportion of MSM with a repeat syphilis infection (P = .42). In a multivariable model, factors associated with repeat syphilis infection were HIV infection (odds ratio [OR] = 1.65; 95% confidence interval [CI] = 1.14, 2.37), Black race (OR = 1.84; 95% CI = 1.12, 3.04), and 10 or more recent sex partners (OR = 1.99; 95% CI = 1.12, 3.50). Conclusions. Approximately 6% of MSM in California have a repeat PS syphilis infection within 2 years of an initial infection. HIV infection, Black race, and having multiple sex partners are associated with increased odds of repeat infection. Syphilis elimination efforts should include messages about the risk for repeat infection and the importance of follow-up testing. Public health attention to individuals repeatedly infected with syphilis may help reduce local disease burdens. PMID:22095364

  19. Relational stressors as predictors for repeat aggressive and self-harming incidents in child and adolescent psychiatric inpatient settings.

    Science.gov (United States)

    Ulke, Christine; Klein, Annette M; von Klitzing, Kai

    2014-01-01

    This study examined whether relational stressors such as psychosocial stressors, the therapist's absence and a change of therapist are associated with repeat aggressive or self-harming incidents in child and adolescent psychiatric inpatient care. The study data were derived from critical incident reports and chart reviews of 107 inpatients. In multinomial regression analysis, patients with repeat aggressive or self-harming incidents were compared with patients with single incidents. Results suggested that a higher number of psychosocial stressors and a change of therapist, but not the therapist's absence are predictors for repeat aggressive and self-harming incidents. There was a high prevalence of therapist's absence during both, single and repeat, incidents. Repeat aggressive incidents were common in male children and adolescents with disruptive behavior disorders. Repeat self-harming incidents were common in adolescent females with trauma-related disorders. Patients with repeat aggressive or self-harming incidents had a higher number of abnormal intrafamilial relationships and acute life events than patients with single incidents. Interventions to reduce a change of therapist should in particular target children and adolescents with a higher number of psychosocial stressors and/or a known history of traumatic relational experiences. After a first incident, patients should have a psychosocial assessment to evaluate whether additional relational support is needed.

  20. Lesser Neural Pattern Similarity across Repeated Tests Is Associated with Better Long-Term Memory Retention.

    Science.gov (United States)

    Karlsson Wirebring, Linnea; Wiklund-Hörnqvist, Carola; Eriksson, Johan; Andersson, Micael; Jonsson, Bert; Nyberg, Lars

    2015-07-01

    Encoding and retrieval processes enhance long-term memory performance. The efficiency of encoding processes has recently been linked to representational consistency: the reactivation of a representation that gets more specific each time an item is further studied. Here we examined the complementary hypothesis of whether the efficiency of retrieval processes also is linked to representational consistency. Alternatively, recurrent retrieval might foster representational variability--the altering or adding of underlying memory representations. Human participants studied 60 Swahili-Swedish word pairs before being scanned with fMRI the same day and 1 week later. On Day 1, participants were tested three times on each word pair, and on Day 7 each pair was tested once. A BOLD signal change in right superior parietal cortex was associated with subsequent memory on Day 1 and with successful long-term retention on Day 7. A representational similarity analysis in this parietal region revealed that beneficial recurrent retrieval was associated with representational variability, such that the pattern similarity on Day 1 was lower for retrieved words subsequently remembered compared with those subsequently forgotten. This was mirrored by a monotonically decreased BOLD signal change in dorsolateral prefrontal cortex on Day 1 as a function of repeated successful retrieval for words subsequently remembered, but not for words subsequently forgotten. This reduction in prefrontal response could reflect reduced demands on cognitive control. Collectively, the results offer novel insights into why memory retention benefits from repeated retrieval, and they suggest fundamental differences between repeated study and repeated testing. Repeated testing is known to produce superior long-term retention of the to-be-learned material compared with repeated encoding and other learning techniques, much because it fosters repeated memory retrieval. This study demonstrates that repeated memory

  1. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  2. Comparison of two techniques for assessing the shaping efficacy of repeatedly used nickel-titanium rotary instruments.

    Science.gov (United States)

    Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone

    2011-06-01

    The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Examining Measures of Weight as Risk Factors for Sport-Related Injury in Adolescents

    OpenAIRE

    Richmond, Sarah A.; Nettel-Aguirre, Alberto; Doyle-Baker, Patricia K.; Macpherson, Alison; Emery, Carolyn A.

    2016-01-01

    Objectives. To examine body mass index (BMI) and waist circumference (WC) as risk factors for sport injury in adolescents. Design. A secondary analysis of prospectively collected data from a pilot cluster randomized controlled trial. Methods. Adolescents (n = 1,040) at the ages of 11?15 years from two Calgary junior high schools were included. BMI (kg/m2) and WC (cm) were measured from direct measures at baseline assessment. Categories (overweight/obese) were created using validated internati...

  4. Novel expressed sequence tag- simple sequence repeats (EST ...

    African Journals Online (AJOL)

    Using different bioinformatic criteria, the SUCEST database was used to mine for simple sequence repeat (SSR) markers. Among 42,189 clusters, 1,425 expressed sequence tag- simple sequence repeats (EST-SSRs) were identified in silico. Trinucleotide repeats were the most abundant SSRs detected. Of 212 primer pairs ...

  5. A novel magnet based 3D printed marker wand as basis for repeated in-shoe multi segment foot analysis: a proof of concept.

    Science.gov (United States)

    Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin

    2017-01-01

    Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.

  6. Role of memory errors in quantum repeaters

    International Nuclear Information System (INIS)

    Hartmann, L.; Kraus, B.; Briegel, H.-J.; Duer, W.

    2007-01-01

    We investigate the influence of memory errors in the quantum repeater scheme for long-range quantum communication. We show that the communication distance is limited in standard operation mode due to memory errors resulting from unavoidable waiting times for classical signals. We show how to overcome these limitations by (i) improving local memory and (ii) introducing two operational modes of the quantum repeater. In both operational modes, the repeater is run blindly, i.e., without waiting for classical signals to arrive. In the first scheme, entanglement purification protocols based on one-way classical communication are used allowing to communicate over arbitrary distances. However, the error thresholds for noise in local control operations are very stringent. The second scheme makes use of entanglement purification protocols with two-way classical communication and inherits the favorable error thresholds of the repeater run in standard mode. One can increase the possible communication distance by an order of magnitude with reasonable overhead in physical resources. We outline the architecture of a quantum repeater that can possibly ensure intercontinental quantum communication

  7. How repeated 15-minute assertiveness training sessions reduce wrist cutting in patients with borderline personality disorder.

    Science.gov (United States)

    Hayakawa, Masaya

    2009-01-01

    The aim of this work was to examine a possible treatment for patients with borderline personality disorder who have wrist-cutting syndrome, a condition characterized by repeated, superficial wrist cutting in a non-suicidal fashion. Within the current healthcare system in Japan, the average amount of time a doctor can spend with a psychiatric outpatient is about 8 to 15 minutes. We, therefore, examined whether repeated 15-minute psychotherapy sessions to improve patient assertiveness would be effective for reducing wrist cutting and possibly other forms of self-mutilation. We treated 13 patients diagnosed with borderline personality disorder and wrist-cutting syndrome with assertiveness training during 15-minute, biweekly therapy sessions over a course of one to four years. At the conclusion of psychotherapeutic treatment, 69% of outpatients showed a statistically significant reduction in wrist-cutting behavior.

  8. Repeated sprint ability in young basketball players: multi-direction vs. one-change of direction (Part 1

    Directory of Open Access Journals (Sweden)

    Johnny ePadulo

    2016-04-01

    Full Text Available The aim of the present study was to examine the reliability of a novel multi-direction repeated sprint ability test (RSM; 10×(6×5-m compared with a repeated sprint ability test (RSA with one change of direction (10×(2×15-m, and the relationship of the RSM and RSA with Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1 and jump performances [squat jump (SJ and counter-movement-jump (CMJ]. Thirty-six (male, n=14, female n=22 young basketball players (age 16.0±0.9 yrs performed the RSM, RSA, Yo-Yo IR1, SJ and CMJ, and were re-tested only for RSM and RSA after one week. The absolute error of reliability (standard error of the measurement was lower than 0.212-s and 0.617-s for the time variables of the RSA and RSM test, respectively. Performance in the RSA and RSM test significantly correlated with CMJ and SJ. The best time, worst time and total time of the RSA and RSM test were negatively correlated with Yo-Yo IR1 distance. Based on these findings, consistent with previously published studies, it was concluded that the novel RSM test was valid and reliable.

  9. PHYSIOLOGICAL RESPONSES AND MOOD STATES AFTER DAILY REPEATED PROLONGED EXERCISE

    Directory of Open Access Journals (Sweden)

    Ilkka Väänänen

    2004-10-01

    Full Text Available The purpose of this study was to describe the physiological responses to daily repeated acute but non-competitive prolonged exercise during a 4-day march and a 2-day cross-country ski event to the cardiorespiratory, autonomic nervous, musculoskeletal and endocrine systems. Mood states were also evaluated after these repeated exercises. The data of these short-term follow-up (reversal field trials was collected from healthy, 23 to 48 year old Finnish male soldiers in 1993 (n=6 and 1994 (n=15 during the "International Four-Day Long-Distance March" in Nijmegen, The Netherlands, and from ten healthy, 22 to 48 year old Finnish male participants in 1995 during a 2-day Finlandia Ski Race in Lahti, Finland. Acute cardiovascular responses were estimated by measuring the heart rate during exercise. The responses of the autonomic nervous system were estimated by measuring the heart rates during the orthostatic test. The musculoskeletal responses were estimated by measuring the perceived pains, flexibility, functional strength, use of elastic energy and oedemic changes of the lower extremities. Hormonal responses were estimated from the urinary excretion of catecholamines, and the concentrations of serum cortisol, testosterone, luteinizing (LH and follicle stimulating hormone (FSH. Mood states were assessed with the Profile of Mood States (POMS questionnaire. Daily walking time was 7-10 hours while the skiing time was 3 hours. Average heart rate during walking was 59% and skiing 87% of maximum heart rate. Morning heart rate in the supine position increased progressively through the marching period but not through the skiing experiment. After the first day, perceived pain increased significantly and remained at a similarly increased level until the end of the exercise period. Leg measurements showed no signs of oedema, decreases in flexibility, or functional strength. Catecholamine excretion rates during marches indicated cumulatively increased

  10. Preventive maintenance measures and repeat tests on actuators

    International Nuclear Information System (INIS)

    Hueren, H.

    1990-01-01

    At Biblis Nuclear Power Station, about 1500 electrical actuators and variable speed drives of various model ranges and with various driving end speeds and actuating times are installed and about 600 of these are located in important safety engineering systems. In order to optimize the preventive maintenance measures on the drives, a data bank has been established into which are stored, in addition to the fixed type data of each drive, inter alia, statements about location of application, valve type, inspection cycle, calendar year of next maintenance, findings during inspection measures and causes of faults. Before each unit inspection, in addition to the inspection lists, the maintenance and installation records and also the associated job instructions are produced from this data processing equipment. (orig.) [de

  11. Dental Fear in Children with Repeated Tooth Injuries.

    Science.gov (United States)

    Negovetić Vranić, Dubravka; Ivančić Jokić, Nataša; Bakarčić, Danko; Carek, Andreja; Rotim, Željko; Verzak, Željko

    2016-06-01

    Tooth injuries are serious clinical conditions. Some children experience dental trauma only once, while others are more prone to repeated tooth injuries. Repeated dental trauma occurs in 19.4% to 30% of patients. Pain and dental trauma are the most common reasons for fear and anxiety. The main objective of this study was to investigate how dental trauma, as well as repeated dental trauma affects the occurrence and development of dental fear in children. The study was conducted on a random sample of 147 subjects (88 boys and 59 girls) aged 5-8 and 9-12 years. Subjects in both age groups were divided into subroups without dental trauma, with one dental trauma and with repeated dental trauma. The validated Children’s Fear Survey Schedule – Dental Subscale was used on fear assessment. Results showed that only 12.2% of children without trauma, 33.3% with one trauma and 51.7% with repeated trauma were not afraid of injection. Older children had a significantly lower fear of injections, touch of an unknown person, choking, going to the hospital and people in white uniforms. Dentist was not the cause of fear in 65.5% of patients with repeated trauma. With each repeated injury of teeth, the degree of their fear of dental treatment was lower.

  12. Erroneous Memories Arising from Repeated Attempts to Remember

    Science.gov (United States)

    Henkel, Linda A.

    2004-01-01

    The impact of repeated and prolonged attempts at remembering on false memory rates was assessed in three experiments. Participants saw and imagined pictures and then made repeated recall attempts before taking a source memory test. Although the number of items recalled increased with repeated tests, the net gains were associated with more source…

  13. Quantitative measurement of intervertebral disc signal using MRI

    International Nuclear Information System (INIS)

    Niemelaeinen, R.; Videman, T.; Dhillon, S.S.; Battie, M.C.

    2008-01-01

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high (≥0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples

  14. Quantitative measurement of intervertebral disc signal using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Niemelaeinen, R. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)], E-mail: riikka.niemelainen@ualberta.ca; Videman, T. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada); Dhillon, S.S. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton (Canada); Battie, M.C. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)

    2008-03-15

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high ({>=}0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples.

  15. The development of the micro-solid propellant thruster array with improved repeatability

    International Nuclear Information System (INIS)

    Seo, Daeban; Kwon, Sejin; Lee, Jongkwang

    2012-01-01

    This paper presents the development of a micro-solid propellant thruster array with improved repeatability. The repeatability and low performance variation of each thruster unit with a high ignition success rate is essential in micro-solid propellant thruster array. To date, the study on the improvement of the repeatability has not yet been reported. As the first step for this study, we propose a new type of micro igniter, using a glass wafer called the heater-contact micro igniter. This igniter is also designed to improve the ignition characteristics of a glass-based micro igniter. The prototype of the igniter array is designed and fabricated to establish its fabrication process and to conduct its performance evaluation. Through the firing test, the performance of the heater-contact micro igniter is verified. The 5 × 5 sized micro-solid propellant thruster array is designed and fabricated applying the developed heater-contact igniter. The measured average thrust of each thruster unit is 2.542 N, and calculated standard deviation is 0.369 N. The calculated average total impulse and its standard deviation are 0.182 and 0.04 mNs, respectively. Based on these results, the improvement of repeatability is verified. Finally, the ignition control system of the micro-thruster array is developed. (paper)

  16. Identification, variation and transcription of pneumococcal repeat sequences

    Science.gov (United States)

    2011-01-01

    Background Small interspersed repeats are commonly found in many bacterial chromosomes. Two families of repeats (BOX and RUP) have previously been identified in the genome of Streptococcus pneumoniae, a nasopharyngeal commensal and respiratory pathogen of humans. However, little is known about the role they play in pneumococcal genetics. Results Analysis of the genome of S. pneumoniae ATCC 700669 revealed the presence of a third repeat family, which we have named SPRITE. All three repeats are present at a reduced density in the genome of the closely related species S. mitis. However, they are almost entirely absent from all other streptococci, although a set of elements related to the pneumococcal BOX repeat was identified in the zoonotic pathogen S. suis. In conjunction with information regarding their distribution within the pneumococcal chromosome, this suggests that it is unlikely that these repeats are specialised sequences performing a particular role for the host, but rather that they constitute parasitic elements. However, comparing insertion sites between pneumococcal sequences indicates that they appear to transpose at a much lower rate than IS elements. Some large BOX elements in S. pneumoniae were found to encode open reading frames on both strands of the genome, whilst another was found to form a composite RNA structure with two T box riboswitches. In multiple cases, such BOX elements were demonstrated as being expressed using directional RNA-seq and RT-PCR. Conclusions BOX, RUP and SPRITE repeats appear to have proliferated extensively throughout the pneumococcal chromosome during the species' past, but novel insertions are currently occurring at a relatively slow rate. Through their extensive secondary structures, they seem likely to affect the expression of genes with which they are co-transcribed. Software for annotation of these repeats is freely available from ftp://ftp.sanger.ac.uk/pub/pathogens/strep_repeats/. PMID:21333003

  17. Repeated causal decision making.

    Science.gov (United States)

    Hagmayer, York; Meder, Björn

    2013-01-01

    Many of our decisions refer to actions that have a causal impact on the external environment. Such actions may not only allow for the mere learning of expected values or utilities but also for acquiring knowledge about the causal structure of our world. We used a repeated decision-making paradigm to examine what kind of knowledge people acquire in such situations and how they use their knowledge to adapt to changes in the decision context. Our studies show that decision makers' behavior is strongly contingent on their causal beliefs and that people exploit their causal knowledge to assess the consequences of changes in the decision problem. A high consistency between hypotheses about causal structure, causally expected values, and actual choices was observed. The experiments show that (a) existing causal hypotheses guide the interpretation of decision feedback, (b) consequences of decisions are used to revise existing causal beliefs, and (c) decision makers use the experienced feedback to induce a causal model of the choice situation even when they have no initial causal hypotheses, which (d) enables them to adapt their choices to changes of the decision problem. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  18. Emergency Department Referrals for Adolescent Urgent Psychiatric Consultation: Comparison of Clinical Characteristics of Repeat-presentations and Single-presentation.

    Science.gov (United States)

    Roberts, Nasreen; Nesdole, Robert; Hu, Tina

    2018-01-01

    a) to examine the demographic and clinical characteristics of repeat-presentations to an adolescent urgent psychiatric clinic, and b) to compare them with single-time presentation. This 18-month retrospective study compared repeat-presenters to age and gender matched single-time presenters. Demographic variables included age gender and ethnicity. Clinical variables included reason for referral, family history, diagnosis, recommendations and compliance. Data were analyzed using descriptive statistics, McNemar's Chi-square tests for matched pairs, and conditional logistic regression. Of 624 assessments 24% (N=151) were repeat-presentations. Compared with single-presentation, repeat-presentation group had a higher proportion of Aboriginal youth (X2 (1) = 108.28 p presentation group had higher odds of past hospital admission (OR: 3.50, p presentations for urgent psychiatric consultation constitute a quarter of referrals to the urgent psychiatric clinic. Identifying and addressing factors that contribute to repeat-presentations may, assist in improving treatment compliance by ensuring focused interventions and service delivery for these youth. In turn, this will improve access to the limited urgent services for other youth.

  19. Cognitive behavioural therapy halves the risk of repeated suicide attempts

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Gøtzsche, Pernille K

    2017-01-01

    is excluded, the risk ratio becomes 0.61 (0.46-0.80) and the heterogeneity in the results disappears (I(2 )= 0%). Conclusions Cognitive behavioural therapy reduces not only repeated self-harm but also repeated suicide attempts. It should be the preferred treatment for all patients with depression.......Objective To study whether cognitive behavioural therapy decreases suicide attempts in people with previous suicide attempts. Design Systematic review and meta-analysis. Setting Randomised trials that compare cognitive behavioural therapy with treatment as usual. Participants Patients who had...... engaged in any type of suicide attempt in the six months prior to trial entry resulting in presentation to clinical services. Main outcome measure Suicide attempt. Results We included ten trials, eight from Cochrane reviews and two from our updated searches (1241 patients, 219 of whom had at least one new...

  20. Factors influencing repeated teenage pregnancy: a review and meta-analysis.

    Science.gov (United States)

    Maravilla, Joemer C; Betts, Kim S; Couto E Cruz, Camila; Alati, Rosa

    2017-11-01

    .14-1.87), history of abortion (pooled odds ratio, 1.66; 95% confidence interval, 1.08-2.54), and relationship factors, such as partner support, increased the repeated teenage pregnancy risk. Contraceptive use, educational factors, depression, and a history of abortion are the highly influential predictors of repeated teenage pregnancy. However, there is a lack of epidemiologic studies in low- and middle-income countries to measure the extent and characteristics of repeated teenage pregnancy across more varied settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    Science.gov (United States)

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  2. Are repeated single-limb heel raises and manual muscle testing associated with peak plantar-flexor force in people with inclusion body myositis?

    Science.gov (United States)

    Harris-Love, Michael O; Shrader, Joseph A; Davenport, Todd E; Joe, Galen; Rakocevic, Goran; McElroy, Beverly; Dalakas, Marinos

    2014-04-01

    Repeated heel raises have been proposed as a method of ankle plantar-flexor strength testing that circumvents the limitations of manual muscle testing (MMT). The study objective was to examine the relationships among ankle plantar-flexion isometric maximum voluntary contraction (MVC), repeated single-limb heel raises (SLHRs), and MMT in people with myositis. This was a cross-sectional study with a between-group design. The ability to complete 1 SLHR determined group assignment (SLHR group, n=24; no-SLHR group, n=19). Forty-three participants with myositis (13 women; median age=64.9 years) participated. Outcome measures included MVC, predicted MVC, Kendall MMT, and Daniels-Worthingham MMT. The Kendall MMT was unable to detect significant ankle plantar-flexor weakness established by quantitative methods and was unable to discriminate between participants who could and those who could not perform the SLHR task. Ankle plantar-flexion MVC was not associated with the number of heel-raise repetitions in the SLHR group (pseudo R(2)=.13). No significant relationship was observed between MVC values and MMT grades in the SLHR and no-SLHR groups. However, a moderate relationship between MVC values and MMT grades was evident in a combined-group analysis (ρ=.50-.67). The lower half of both MMT grading scales was not represented in the study despite the profound weakness of the participants. Both Kendall MMT and Daniels-Worthingham MMT had limited utility in the assessment of ankle plantar-flexor strength. Repeated SLHRs should not be used as a proxy measure of ankle plantar-flexion MVC in people with myositis.

  3. Deployment Repeatability

    Science.gov (United States)

    2016-08-31

    large cohort of trials to spot unusual cases. However, deployment repeatability is inherently a nonlinear phenomenon, which makes modeling difficult...and GEMS tip position were both tracked during ground testing by a laser target tracking system. Earlier SAILMAST testing in 2005 [8] used...recalls the strategy used by SRTM, where a constellation of lights was installed at the tip of the boom and a modified star tracker was used to track tip

  4. Variable presence of the inverted repeat and plastome stability in Erodium

    OpenAIRE

    Blazier, John C.; Jansen, Robert K.; Mower, Jeffrey P.; Govindu, Madhu; Zhang, Jin; Weng, Mao-Lun; Ruhlman, Tracey A.

    2016-01-01

    Background and Aims Several unrelated lineages such as plastids, viruses and plasmids, have converged on quadripartite genomes of similar size with large and small single copy regions and a large inverted repeat (IR). Except for Erodium (Geraniaceae), saguaro cactus and some legumes, the plastomes of all photosynthetic angiosperms display this structure. The functional significance of the IR is not understood and Erodium provides a system to examine the role of the IR in the long-term stabili...

  5. Repeated superovulation increases the risk of osteoporosis and cardiovascular diseases by accelerating ovarian aging in mice.

    Science.gov (United States)

    Zhang, Jinjin; Lai, Zhiwen; Shi, Liangyan; Tian, Yong; Luo, Aiyue; Xu, Zheyuan; Ma, Xiangyi; Wang, Shixuan

    2018-05-22

    Superovulation procedures and assisted reproductive technologies have been widely used to treat couples who have infertility problems. Although generally safe, the superovulation procedures are associated with a series of complications, such as ovarian hyper-stimulation syndrome, thromboembolism, and adnexal torsion. The role of long-term repeated superovulation in ovarian aging and especially in associated disorders such as osteoporosis and cardiovascular diseases is still unclear. In this study, we sought to determine if repeated superovulation by ten cycles of treatment with pregnant mare serum gonadotropin/human chorionic gonadotropin could affect ovarian reserve, ovarian function, bone density and heart function. Ovarian reserve and function were reflected by the size of the primordial follicle pool, anti-Mullerian hormone expressions, hormone levels and fertility status. Furthermore, we examined bone density and heart function by microCT and cardiovascular ultrasonography, respectively. After repeated superovulation, the size of the primordial follicle pool and the expression of anti-mullerian hormone decreased, along with the concentrations of estrogen and progesterone. Mice exposed to repeated superovulation showed an obvious decrease in fertility and fecundity. Furthermore, both bone density and heart ejection fraction significantly decreased. These results suggest that repeated superovulation may increase the risk of osteoporosis and cardiovascular diseases by accelerating ovarian aging.

  6. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  7. Cost-effectiveness analysis of repeat fine-needle aspiration for thyroid biopsies read as atypia of undetermined significance.

    Science.gov (United States)

    Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord

    2012-09-01

    The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.

  8. R-loops: targets for nuclease cleavage and repeat instability.

    Science.gov (United States)

    Freudenreich, Catherine H

    2018-01-11

    R-loops form when transcribed RNA remains bound to its DNA template to form a stable RNA:DNA hybrid. Stable R-loops form when the RNA is purine-rich, and are further stabilized by DNA secondary structures on the non-template strand. Interestingly, many expandable and disease-causing repeat sequences form stable R-loops, and R-loops can contribute to repeat instability. Repeat expansions are responsible for multiple neurodegenerative diseases, including Huntington's disease, myotonic dystrophy, and several types of ataxias. Recently, it was found that R-loops at an expanded CAG/CTG repeat tract cause DNA breaks as well as repeat instability (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Two factors were identified as causing R-loop-dependent breaks at CAG/CTG tracts: deamination of cytosines and the MutLγ (Mlh1-Mlh3) endonuclease, defining two new mechanisms for how R-loops can generate DNA breaks (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Following R-loop-dependent nicking, base excision repair resulted in repeat instability. These results have implications for human repeat expansion diseases and provide a paradigm for how RNA:DNA hybrids can cause genome instability at structure-forming DNA sequences. This perspective summarizes mechanisms of R-loop-induced fragility at G-rich repeats and new links between DNA breaks and repeat instability.

  9. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  10. Experimental evaluation of rigor mortis. VIII. Estimation of time since death by repeated measurements of the intensity of rigor mortis on rats.

    Science.gov (United States)

    Krompecher, T

    1994-10-21

    The development of the intensity of rigor mortis was monitored in nine groups of rats. The measurements were initiated after 2, 4, 5, 6, 8, 12, 15, 24, and 48 h post mortem (p.m.) and lasted 5-9 h, which ideally should correspond to the usual procedure after the discovery of a corpse. The experiments were carried out at an ambient temperature of 24 degrees C. Measurements initiated early after death resulted in curves with a rising portion, a plateau, and a descending slope. Delaying the initial measurement translated into shorter rising portions, and curves initiated 8 h p.m. or later are comprised of a plateau and/or a downward slope only. Three different phases were observed suggesting simple rules that can help estimate the time since death: (1) if an increase in intensity was found, the initial measurements were conducted not later than 5 h p.m.; (2) if only a decrease in intensity was observed, the initial measurements were conducted not earlier than 7 h p.m.; and (3) at 24 h p.m., the resolution is complete, and no further changes in intensity should occur. Our results clearly demonstrate that repeated measurements of the intensity of rigor mortis allow a more accurate estimation of the time since death of the experimental animals than the single measurement method used earlier. A critical review of the literature on the estimation of time since death on the basis of objective measurements of the intensity of rigor mortis is also presented.

  11. Repeat profile analysis in an x-ray department

    International Nuclear Information System (INIS)

    Bassey, C.E.; Ojo, O.O.; Akpabio, I.

    1991-01-01

    The repeat profile of an x-ray department in a developing country was analysed monthly between July 1989 and June 1990. Results showed an average repeat rate of 3.7% for the period of study. The main causes of film repetition were: equipment fault, 33.9%; radiographer's fault, 27.4%; film fault, 19.3%; processing fault, 10.8% and patient's fault, 8.6%. The average repeat rate in the first 6 months of study reduced by 50% in the last 6 months. This was due to the effectiveness of implementation of corrective actions. The overall repeat rate was found to correlate well with both the equipment fault and radiographer's fault with correlation coefficients, r, of 0.94 and 0.91, respectively. It is expected that a further reduction in the repeat rate will be obtained after the introduction of quality assurance programmes. (author)

  12. Exceptionally long 5' UTR short tandem repeats specifically linked to primates.

    Science.gov (United States)

    Namdar-Aligoodarzi, P; Mohammadparast, S; Zaker-Kandjani, B; Talebi Kakroodi, S; Jafari Vesiehsari, M; Ohadi, M

    2015-09-10

    We have previously reported genome-scale short tandem repeats (STRs) in the core promoter interval (i.e. -120 to +1 to the transcription start site) of protein-coding genes that have evolved identically in primates vs. non-primates. Those STRs may function as evolutionary switch codes for primate speciation. In the current study, we used the Ensembl database to analyze the 5' untranslated region (5' UTR) between +1 and +60 of the transcription start site of the entire human protein-coding genes annotated in the GeneCards database, in order to identify "exceptionally long" STRs (≥5-repeats), which may be of selective/adaptive advantage. The importance of this critical interval is its function as core promoter, and its effect on transcription and translation. In order to minimize ascertainment bias, we analyzed the evolutionary status of the human 5' UTR STRs of ≥5-repeats in several species encompassing six major orders and superorders across mammals, including primates, rodents, Scandentia, Laurasiatheria, Afrotheria, and Xenarthra. We introduce primate-specific STRs, and STRs which have expanded from mouse to primates. Identical co-occurrence of the identified STRs of rare average frequency between 0.006 and 0.0001 in primates supports a role for those motifs in processes that diverged primates from other mammals, such as neuronal differentiation (e.g. APOD and FGF4), and craniofacial development (e.g. FILIP1L). A number of the identified STRs of ≥5-repeats may be human-specific (e.g. ZMYM3 and DAZAP1). Future work is warranted to examine the importance of the listed genes in primate/human evolution, development, and disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Context matters! sources of variability in weekend physical activity among families: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Robert J. Noonan

    2017-04-01

    Full Text Available Abstract Background Family involvement is an essential component of effective physical activity (PA interventions in children. However, little is known about the PA levels and characteristics of PA among families. This study used a repeated measures design and multiple data sources to explore the variability and characteristics of weekend PA among families. Methods Families (including a ‘target’ child aged 9–11 years, their primary caregiver(s and siblings aged 6–8 years were recruited through primary schools in Liverpool, UK. Participants completed a paper-based PA diary and wore an ActiGraph GT9X accelerometer on their left wrist for up to 16 weekend days. ActiGraph.csv files were analysed using the R-package GGIR version 1.1–4. Mean minutes of moderate-to-vigorous PA (MVPA for each weekend of measurement were calculated using linear mixed models, and variance components were estimated for participant (inter-individual, weekend of measurement, and residual error (intra-individual. Intraclass correlation coefficients (ICC were calculated from the proportion of total variance accounted for by inter-individual sources, and used as a measure of reliability. Diary responses were summed to produce frequency counts. To offer contextual insight into weekend PA among family units, demographic, accelerometer, and diary data were combined to form two case studies representative of low and high active families. Results Twenty-five participants from 7 families participated, including 7 ‘target’ children (mean age 9.3 ± 1.1 years, 4 boys, 6 siblings (mean age 7.2 ± 0.7 years; 4 boys and 12 adults (7 mothers and 5 fathers. There was a high degree of variability in target children’s (ICC = 0.55, siblings (ICC = 0.38, and mothers’ MVPA (ICC = 0.58, but not in fathers’ MVPA (ICC = 0.83. Children’s weekend PA was mostly unstructured in nature and undertaken with friends, whereas a greater proportion of parents’ weekend

  14. The "saying is repeating" effect: dyadic communication can generate cultural stereotypes.

    Science.gov (United States)

    Bratanova, Boyka; Kashima, Yoshi

    2014-01-01

    It has been long established that interpersonal communication underpins the existence of cultural stereotypes. However, research has either examined the formation of new or the maintenance of existing stereotypes. In a series of three studies, the present research bridges the gap between these phases by showing that newly formed stereotypes can spread through repeated dyadic communication with others. The stereotypic representation arose due to the audience tuning in to communication to a first audience. Further transmission to two types of subsequent audiences was simulated: a newcomer and an old-timer with an unknown attitude towards the target. A "saying-is-repeating" effect was obtained: the stereotypic representation was invariably transmitted to the newcomer, regardless of whether communicators personally believed in the bias; perceived group-level consensus moderated its transmission to the old-timer. These findings demonstrate that once a stereotypic representation is formed, it is likely to spread in a community and potentially become a cultural stereotype.

  15. Repeated Sprint Ability in Young Basketball Players: Multi-direction vs. One-Change of Direction (Part 1)

    OpenAIRE

    Padulo, Johnny; Bragazzi, Nicola L.; Nikolaidis, Pantelis T.; Dello Iacono, Antonio; Attene, Giuseppe; Pizzolato, Fabio; Dal Pupo, Juliano; Zagatto, Alessandro M.; Oggianu, Marcello; Migliaccio, Gian M.

    2016-01-01

    The aim of the present study was to examine the reliability of a novel multi-direction repeated sprint ability test (RSM; 10×(6×5-m)) compared with a repeated sprint ability test (RSA) with one change of direction (10×(2×15-m)), and the relationship of the RSM and RSA with Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) and jump performances [squat jump (SJ) and counter-movement-jump (CMJ)]. Thirty-six (male, n=14, female n=22) young basketball players (age 16.0±0.9 yrs) performed the RS...

  16. Experimental study on the long-term effect of cadmium in mice fed cadmium-polluted rice with special reference to the effect of repeated reproductive cycles

    International Nuclear Information System (INIS)

    Watanabe, M.; Shiroishi, K.; Nishino, H.; Shinmura, T.; Murase, H.; Shoji, T.; Naruse, Y.; Kagamimori, S.

    1986-01-01

    Long-term biological effects of cadmium-polluted rice and effect of repeated reproductive cycles on them were examined. Female SLC-B6D2F mice (female C57BL/6, male DBA/2) were fed a rice diet containing 65% unpolished rice for about 2 years from 7 weeks of age. The unpolished rice preparations used were commercially available rice (non-Cd-polluted) and Cd-polluted rice (over 1.0 ppm). Average Cd contents in each diet class were 0.12, 0.48, 1.78, 1.75, and 47.1 ppm (50 ppm Cd as CdCl 2 added). Some experimental mice were subjected to repeated reproductive cycles (parity group). Hematological, biochemical, and pathological examinations of urine, blood, and tissues, including Cd measurement, were carried out. Results after statistical analysis indicate Cd toxicities such as anemia and disturbances of Ca metabolism. These Cd effects were found to be enhanced by the reproductive cycles. Soft X-ray radiograms showed osteoporosis in the parity groups, especially in the groups with diets of higher Cd content. However, we could not find any sign of disturbance of renal function under our experimental conditions

  17. Agreement and repeatability of vascular reactivity estimates based on a breath-hold task and a resting state scan.

    Science.gov (United States)

    Lipp, Ilona; Murphy, Kevin; Caseras, Xavier; Wise, Richard G

    2015-06-01

    FMRI BOLD responses to changes in neural activity are influenced by the reactivity of the vasculature. By complementing a task-related BOLD acquisition with a vascular reactivity measure obtained through breath-holding or hypercapnia, this unwanted variance can be statistically reduced in the BOLD responses of interest. Recently, it has been suggested that vascular reactivity can also be estimated using a resting state scan. This study aimed to compare three breath-hold based analysis approaches (block design, sine-cosine regressor and CO2 regressor) and a resting state approach (CO2 regressor) to measure vascular reactivity. We tested BOLD variance explained by the model and repeatability of the measures. Fifteen healthy participants underwent a breath-hold task and a resting state scan with end-tidal CO2 being recorded during both. Vascular reactivity was defined as CO2-related BOLD percent signal change/mmHg change in CO2. Maps and regional vascular reactivity estimates showed high repeatability when the breath-hold task was used. Repeatability and variance explained by the CO2 trace regressor were lower for the resting state data based approach, which resulted in highly variable measures of vascular reactivity. We conclude that breath-hold based vascular reactivity estimations are more repeatable than resting-based estimates, and that there are limitations with replacing breath-hold scans by resting state scans for vascular reactivity assessment. Copyright © 2015. Published by Elsevier Inc.

  18. Repeated isoflurane exposure and neuroapoptosis in the midgestation fetal sheep brain.

    Science.gov (United States)

    Olutoye, Olutoyin A; Sheikh, Fariha; Zamora, Irving J; Yu, Ling; Akinkuotu, Adesola C; Adesina, Adekunle M; Olutoye, Oluyinka O

    2016-04-01

    Advances in surgery and technology have resulted in increased in-utero procedures. However, the effect of anesthesia on the fetal brain is not fully known. The inhalational anesthetic agent, isoflurane, other gamma amino butyric acid agonists (benzodiazepines, barbiturates, propofol, other inhalation anesthetics), and N-methyl D aspartate antagonists, eg, ketamine, have been shown to induce neuroapoptosis. The ovine model has been used extensively to study maternal-fetal physiologic interactions and to investigate different surgical interventions on the fetus. The purpose of this study was to determine effects of different doses and duration of isoflurane on neuroapoptosis in midgestation fetal sheep. We hypothesized that repeated anesthetic exposure and high concentrations of isoflurane would result in increased neuroapoptosis. Time-dated, pregnant sheep at 70 days gestation (term 145 days) received either isoflurane 2% × 1 hour, 4% × 3 hours, or 2% × 1 hour every other day for 3 exposures (repeated exposure group). Euthanasia occurred following anesthetic exposure and fetal brains were processed. Neuroapoptosis was detected by immunohistochemistry using anticaspase-3 antibodies. Fetuses unexposed to anesthesia served as controls. Another midgestation group with repeated 2% isoflurane exposure was examined at day 130 (long-term group) and neuronal cell density compared to age-matched controls. Representative sections of the brain were analyzed using Aperio Digital imaging (Leica Microsystems Inc, Buffalo Grove, IL). Data, reported by number of neurons per cubic millimeter of brain tissue are presented as means and SEM. Data were analyzed using the Mann-Whitney U and Kruskal-Wallis tests as appropriate. A total of 34 fetuses were studied. There was no significant difference in neuroapoptosis observed in fetuses exposed to 2% isoflurane for 1 hour or 4% isoflurane for 3 hours. Increased neuroapoptosis was observed in the frontal cortex following repeated 2

  19. Overexpression of MIP2, a novel WD-repeat protein, promotes proliferation of H9c2 cells

    International Nuclear Information System (INIS)

    Wei, Xing; Song, Lan; Jiang, Lei; Wang, Guiliang; Luo, Xinjing; Zhang, Bin; Xiao, Xianzhong

    2010-01-01

    WD40 repeat proteins have a wide range of diverse biological functions including signal transduction, cell cycle regulation, RNA splicing, and transcription. Myocardial ischemic preconditioning up-regulated protein 2 (MIP2) is a novel member of the WD40 repeat proteins superfamily that contains five WD40 repeats. Little is known about its biological role, and the purpose of this study was to determine the role of MIP2 in regulating cellular proliferation. Transfection and constitutive expression of MIP2 in the rat cardiomyoblast cell line H9c2 results in enhanced growth of those cells as measured by cell number and is proportional to the amount of MIP2 expressed. Overexpression of MIP2 results in a shorter cell cycle, as measured by flow cytometry. Collectively, these data suggest that MIP2 may participate in the progression of cell proliferation in H9c2 cells.

  20. Repeated Sleep Restriction in Adolescent Rats Altered Sleep Patterns and Impaired Spatial Learning/Memory Ability

    Science.gov (United States)

    Yang, Su-Rong; Sun, Hui; Huang, Zhi-Li; Yao, Ming-Hui; Qu, Wei-Min

    2012-01-01

    Study Objectives: To investigate possible differences in the effect of repeated sleep restriction (RSR) during adolescence and adulthood on sleep homeostasis and spatial learning and memory ability. Design: The authors examined electroencephalograms of rats as they were subjected to 4-h daily sleep deprivation that continued for 7 consecutive days and assessed the spatial learning and memory by Morris water maze test (WMT). Participants: Adolescent and adult rats. Measurements and Results: Adolescent rats exhibited a similar amount of rapid eye movement (REM) and nonrapid eye movement (NREM) sleep with higher slow wave activity (SWA, 0.5-4 Hz) and fewer episodes and conversions with prolonged durations, indicating they have better sleep quality than adult rats. After RSR, adult rats showed strong rebound of REM sleep by 31% on sleep deprivation day 1; this value was 37% on sleep deprivation day 7 in adolescents compared with 20-h baseline level. On sleep deprivation day 7, SWA in adult and adolescent rats increased by 47% and 33%, and such elevation lasted for 5 h and 7 h, respectively. Furthermore, the authors investigated the effects of 4-h daily sleep deprivation immediately after the water maze training sessions on spatial cognitive performance. Adolescent rats sleep-restricted for 7 days traveled a longer distance to find the hidden platform during the acquisition training and had fewer numbers of platform crossings in the probe trial than those in the control group, something that did not occur in the sleep-deprived adult rats. Conclusions: Repeated sleep restriction (RSR) altered sleep profiles and mildly impaired spatial learning and memory capability in adolescent rats. Citation: Yang SR; Sun H; Huang ZL; Yao MH; Qu WM. Repeated sleep restriction in adolescent rats altered sleep patterns and impaired spatial learning/memory ability. SLEEP 2012;35(6):849-859. PMID:22654204

  1. Repeatability of the Oxford Foot Model for Kinematic Gait Analysis of the Foot and Ankle

    NARCIS (Netherlands)

    van Hoeve, S.; Vos, J.; Weijers, P.; Verbruggen, J.; Willems, P.; Poeze, M.; Meijer, K.

    2015-01-01

    INTRODUCTION: Kinematic gait analysis via the multi-segmental Oxford foot model (OFM) may be a valuable addition to the biomechanical examination of the foot and ankle. The aim of this study is to assess the repeatability of the OFM in healthy subjects. METHODS: Nine healthy subjects, without a

  2. Acquiring a cognitive skill with a new repeating version of the Tower of London task.

    Science.gov (United States)

    Ouellet, Marie-Christine; Beauchamp, Miriam H; Owen, Adrian M; Doyon, Julien

    2004-12-01

    A computerized version of the Tower of London task was used to investigate cognitive skill learning. Thirty-six healthy volunteers were assigned to either a random condition (nonrecurring problems), or to a sequence condition in which, unbeknownst to the subjects, a repeating sequence of three problems was presented. Indices of execution, planning, and total time, as well as number of moves performed, were used to measure behavioural change. Subjects' performance improved in both conditions across blocks of practice. A distinct learning effect related to the repeating sequence was also observed. This suggests that a specific skill that reflects procedural learning of the strategies, rules, and procedures pertaining to repeating problems can develop over and above a more general skill at solving cognitive planning problems with practice.

  3. GENETIC DIVERSITY OF TYPHA LATIFOLIA (TYPHACEAE) AND THE IMPACT OF POLLUTANTS EXAMINED WITH TANDEM-REPETITIVE DNA PROBES

    Science.gov (United States)

    Genetic diversity at variable-number-tandem-repeat (VNTR) loci was examined in the common cattail, Typha latifolia (Typhaceae), using three synthetic DNA probes composed of tandemly repeated "core" sequences (GACA, GATA, and GCAC). The principal objectives of this investigation w...

  4. Muscle damage and repeated bout effect induced by enhanced eccentric squats.

    Science.gov (United States)

    Coratella, Giuseppe; Chemello, Alessandro; Schena, Federico

    2016-12-01

    Muscle damage and repeated bout effect have been studied after pure eccentric-only exercise. The aim of this study was to evaluate muscle damage and repeated bout effect induced by enhanced eccentric squat exercise using flywheel device. Thirteen healthy males volunteered for this study. Creatine kinase blood activity (CK), quadriceps isometric peak torque and muscle soreness were used as markers of muscle damage. The dependent parameters were measured at baseline, immediately after and each day up to 96 hours after the exercise session. The intervention consisted of 100 repetitions of enhanced eccentric squat exercise using flywheel device. The same protocol was repeated after 4 weeks. After the first bout, CK and muscle soreness were significantly greater (P0.05), while isometric peak torque and muscle soreness returned to values similar to baseline after respectively 48 and 72 hours. All muscle damage markers were significantly lower after second compared to first bout. The enhanced eccentric exercise induced symptoms of muscle damage up to 96 hours. However, it provided muscle protection after the second bout, performed four weeks later. Although it was not eccentric-only exercise, the enhancement of eccentric phase provided muscle protection.

  5. Strategic Interviewing to Detect Deception: Cues to Deception across Repeated Interviews

    Directory of Open Access Journals (Sweden)

    Jaume Masip

    2016-11-01

    Full Text Available Previous deception research on repeated interviews found that liars are not less consistent than truth tellers, presumably because liars use a repeat strategy to be consistent across interviews. The goal of this study was to design an interview procedure to overcome this strategy. Innocent participants (truth tellers and guilty participants (liars had to convince an interviewer that they had performed several innocent activities rather than committing a mock crime. The interview focused on the innocent activities (alibi, contained specific central and peripheral questions, and was repeated after one week without forewarning. Cognitive load was increased by asking participants to reply quickly. The liars’ answers in replying to both central and peripheral questions were significantly less accurate, less consistent, and more evasive than the truth tellers’ answers. Logistic regression analyses yielded classification rates ranging from around 70% (with consistency as the predictor variable, 85% (with evasive answers as the predictor variable, to over 90% (with an improved measure of consistency that incorporated evasive answers as the predictor variable, as well as with response accuracy as the predictor variable. These classification rates were higher than the interviewers’ accuracy rate (54%.

  6. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    Science.gov (United States)

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  7. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    International Nuclear Information System (INIS)

    Hinzpeter, Ricarda; Sprengel, Kai; Wanner, Guido A.; Mildenberger, Peter; Alkadhi, Hatem

    2017-01-01

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  8. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    Energy Technology Data Exchange (ETDEWEB)

    Hinzpeter, Ricarda, E-mail: Ricarda.Hinzpeter@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland); Sprengel, Kai, E-mail: Kai.Sprengel@usz.ch [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Wanner, Guido A., E-mail: Guido.Wanner@sbk-vs.de [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Department of General Surgery, Schwarzwald-Baar Klinikum, University of Freiburg, Klinikstr. 11, D-78052 Villingen-Schwenningen (Germany); Mildenberger, Peter, E-mail: peter.mildenberger@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, University Hospital of Mainz, Langenbeckstr. 1, D-55131 Mainz (Germany); Alkadhi, Hatem, E-mail: hatem.alkadhi@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland)

    2017-03-15

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  9. Comparison of step-by-step kinematics in repeated 30m sprints in female soccer players.

    Science.gov (United States)

    van den Tillaar, Roland

    2018-01-04

    The aim of this study was to compare kinematics in repeated 30m sprints in female soccer players. Seventeen subjects performed seven 30m sprints every 30s in one session. Kinematics were measured with an infrared contact mat and laser gun, and running times with an electronic timing device. The main findings were that sprint times increased in the repeated sprint ability test. The main changes in kinematics during the repeated sprint ability test were increased contact time and decreased step frequency, while no change in step length was observed. The step velocity increased in almost each step until the 14, which occurred around 22m. After this, the velocity was stable until the last step, when it decreased. This increase in step velocity was mainly caused by the increased step length and decreased contact times. It was concluded that the fatigue induced in repeated 30m sprints in female soccer players resulted in decreased step frequency and increased contact time. Employing this approach in combination with a laser gun and infrared mat for 30m makes it very easy to analyse running kinematics in repeated sprints in training. This extra information gives the athlete, coach and sports scientist the opportunity to give more detailed feedback and help to target these changes in kinematics better to enhance repeated sprint performance.

  10. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  11. Quality control during repeated fryings

    Directory of Open Access Journals (Sweden)

    Cuesta, C.

    1998-08-01

    Full Text Available Most of the debate ¡s about how the slow or frequent turnover of fresh fat affects the deterioration, of fat used in frying. Then, the modification of different oils used in repeated fryings of potatoes without or with turnover of fresh oil, under similar frying conditions, was evaluated by two criteria: by measuring the total polar component isolated by column chromatography and by the evaluation of the specific compounds related to thermoxidative and hydrolytic alteration by High Performance Size Exclusion Chromatography (HPSEC. The results indicate that with frequent turnover of fresh oil, the critical level of 25% of polar material is rarely reached, and there are fewer problems with fat deterioration because the frying tended to increase the level of polar material and thermoxidative compounds (polymers and dimers of triglycerides and oxidized triglycerides in the fryer oil during the first fryings, followed by minor changes and a tendency to reach a near-steady state in successive fryings. However, in repeated frying of potatoes using a null turnover the alteration rate was higher being linear the relationship found between polar material or the different thermoxidative compounds and the number of fryings. On the other hand chemical reactions produced during deep-fat frying can be minimized by using proper oils. In addition the increased level of consumers awareness toward fat composition and its impact on human health could had an impact on the selection of fats for snacks and for industry. In this way monoenic fats are the most adequate from a nutritional point of view and for its oxidative stability during frying.

  12. Anterior prostate biopsy at initial and repeat evaluation: is it useful to detect significant prostate cancer?

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2015-10-01

    Full Text Available ABSTRACT Purpose: Detection rate for anterior prostate cancer (PCa in men who underwent initial and repeat biopsy has been prospectively evaluated. Materials and Methods: From January 2013 to March 2014, 400 patients all of Caucasian origin (median age 63.5 years underwent initial (285 cases and repeat (115 cases prostate biopsy; all the men had negative digital rectal examination and the indications to biopsy were: PSA values > 10 ng/mL, PSA between 4.1-10 or 2.6-4 ng/mL with free/total PSA≤25% and ≤20%, respectively. A median of 22 (initial biopsy and 31 cores (repeat biopsy were transperineally performed including 4 cores of the anterior zone (AZ and 4 cores of the AZ plus 2 cores of the transition zone (TZ, respectively. Results: Median PSA was 7.9 ng/mL; overall, a PCa was found in 180 (45% patients: in 135 (47.4% and 45 (36% of the men who underwent initial and repeat biopsy, respectively. An exclusive PCa of the anterior zone was found in the 8.9 (initial biopsy vs 13.3% (repeat biopsy of the men: a single microfocus of cancer was found in the 61.2% of the cases; moreover, in 7 out 18 AZ PCa the biopsy histology was predictive of significant cancer in 2 (28.5% and 5 (71.5% men who underwent initial and repeat biopsy, respectively. Conclusions: However AZ biopsies increased detection rate for PCa (10% of the cases, the majority of AZ PCa with histological findings predictive of clinically significant cancer were found at repeat biopsy (about 70% of the cases.

  13. [Effects of repeated firing on microleakage of selective laser melting ceramic crowns].

    Science.gov (United States)

    Zhong, Qun; Peng, Yan; Wu, Xue-Ying; Weng, Jia-Wei

    2016-12-01

    To investigate the effects of repeated firing on microleakage of selective laser melting ceramic crowns. Fifty molars were randomly divided into 2 groups (25 teeth in each group). Teeth in group A received a chamfer finish line preparation, whereas teeth in group B received a shoulder finish line. After SLM metal crowns were fabricated, all the crowns received initial oxidation step, opaque firing, dentin firing and glaze firing, then crowns in each group were randomly divided into 5 sub-groups according to different time of clinical firings. Glass ionomer was applied for bonding. After 5000 thermocycles ranging from 5degrees centigrade to 55degrees centigrade, all the specimens was evaluated by dye penetration and then microleakage was examined under light microscopy. The data were analyzed with SPSS 20.0 software package. Microleakage between all specimens of group A were not statistically significant (P>0.05) whereas that of group B were statistically significant (P<0.05); After the fifth time of clinical firing, microleakage of specimens in group B(B5) were significantly higher than that of group A(A5). Repeated firings had no significant influence on marginal microleakage of SLM ceramic crowns whereas the crowns of chamfer finish lines result in better clinical performance after repeated firings.

  14. Examining Effects of Physical Exertion on the Dynamic Visual Acuity Test in Collegiate Athletes.

    Science.gov (United States)

    Patterson, Jessie N; Murphy, Anna M; Honaker, Julie A

    2017-01-01

    Acute symptoms of dizziness and/or imbalance commonly experienced in athletes postconcussion are speculated to arise from dysfunction at multiple levels (i.e., inner ear or central vestibular system) to appropriately integrate afferent sensory information. Disruption along any pathway of the balance system can result in symptoms of dizziness, decreased postural control function (vestibulospinal reflex), and reduced vestibulo-ocular reflex function. This may also lead to decreased gaze stability with movements of the head and may account for symptoms of blurred vision or diplopia reported in almost half of athletes sustaining a concussion. Current concussion position statements include measures of postural control to examine changes to the balance system postconcussion. The Balance Error Scoring System (BESS) is a commonly used low-cost postural control measure for concussion assessment. Although this is a widely used measure for documenting balance function on both immediate (sideline) and recovery monitoring, the BESS has been shown to be affected by physical exertion. Therefore, the BESS may not be the most efficient means of examining functional changes to the balance system immediately after head injury. Dynamic Visual Acuity Test (DVAT) has been found to effectively evaluate and monitor changes to the gaze stability system postinjury. Thus, DVAT may be an additional measure in the concussion assessment battery, as well as an alternative for more immediate sideline assessment to help make objective return-to-play decisions. The aim of the study was to determine the effects of physical exertion on a clinical vestibular assessment, the DVAT, in collegiate athletes, as a first step in defining the role of this measure in the concussion assessment battery. Cross-sectional, repeated-measures design. Twenty-eight healthy collegiate athletes (20 males, 8 females; age = 20.25 ± 1.46 yr, range = 18-25 yr) volunteered to participate in the study. Participants were

  15. Development of analog watch with minute repeater

    Science.gov (United States)

    Okigami, Tomio; Aoyama, Shigeru; Osa, Takashi; Igarashi, Kiyotaka; Ikegami, Tomomi

    A complementary metal oxide semiconductor with large scale integration was developed for an electronic minute repeater. It is equipped with the synthetic struck sound circuit to generate natural struck sound necessary for the minute repeater. This circuit consists of an envelope curve drawing circuit, frequency mixer, polyphonic mixer, and booster circuit made by using analog circuit technology. This large scale integration is a single chip microcomputer with motor drivers and input ports in addition to the synthetic struck sound circuit, and it is possible to make an electronic system of minute repeater at a very low cost in comparison with the conventional type.

  16. RTEL1 Inhibits Trinucleotide Repeat Expansions and Fragility

    Directory of Open Access Journals (Sweden)

    Aisling Frizzell

    2014-03-01

    Full Text Available Human RTEL1 is an essential, multifunctional helicase that maintains telomeres, regulates homologous recombination, and helps prevent bone marrow failure. Here, we show that RTEL1 also blocks trinucleotide repeat expansions, the causal mutation for 17 neurological diseases. Increased expansion frequencies of (CTG⋅CAG repeats occurred in human cells following knockdown of RTEL1, but not the alternative helicase Fbh1, and purified RTEL1 efficiently unwound triplet repeat hairpins in vitro. The expansion-blocking activity of RTEL1 also required Rad18 and HLTF, homologs of yeast Rad18 and Rad5. These findings are reminiscent of budding yeast Srs2, which inhibits expansions, unwinds hairpins, and prevents triplet-repeat-induced chromosome fragility. Accordingly, we found expansions and fragility were suppressed in yeast srs2 mutants expressing RTEL1, but not Fbh1. We propose that RTEL1 serves as a human analog of Srs2 to inhibit (CTG⋅CAG repeat expansions and fragility, likely by unwinding problematic hairpins.

  17. Isolation of human simple repeat loci by hybridization selection.

    Science.gov (United States)

    Armour, J A; Neumann, R; Gobert, S; Jeffreys, A J

    1994-04-01

    We have isolated short tandem repeat arrays from the human genome, using a rapid method involving filter hybridization to enrich for tri- or tetranucleotide tandem repeats. About 30% of clones from the enriched library cross-hybridize with probes containing trimeric or tetrameric tandem arrays, facilitating the rapid isolation of large numbers of clones. In an initial analysis of 54 clones, 46 different tandem arrays were identified. Analysis of these tandem repeat loci by PCR showed that 24 were polymorphic in length; substantially higher levels of polymorphism were displayed by the tetrameric repeat loci isolated than by the trimeric repeats. Primary mapping of these loci by linkage analysis showed that they derive from 17 chromosomes, including the X chromosome. We anticipate the use of this strategy for the efficient isolation of tandem repeats from other sources of genomic DNA, including DNA from flow-sorted chromosomes, and from other species.

  18. Repeated tumor pO2 measurements by multi-site EPR oximetry as a prognostic marker for enhanced therapeutic efficacy of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Hou Huagang; Lariviere, Jean P.; Demidenko, Eugene; Gladstone, David; Swartz, Harold; Khan, Nadeem

    2009-01-01

    Purpose: To investigate the temporal effects of single or fractionated radiotherapy on subcutaneous RIF-1 tumor pO 2 and to determine the therapeutic outcomes when the timing of fractionations is guided by tumor pO 2 . Methods: The time-course of the tumor pO 2 changes was followed by multi-site electron paramagnetic resonance (EPR) oximetry. The tumors were treated with single 10, 20, and 10 Gy x 2 doses, and the tumor pO 2 was measured repeatedly for six consecutive days. In the 10 Gy x 2 group, the second dose of 10 Gy was delivered at a time when the tumors were either relatively oxygenated or hypoxic. The changes in tumor volumes were followed for nine days to determine the therapeutic outcomes. Results: A significant increase in tumor pO 2 was observed at 24 h post 10 Gy, while 20 Gy resulted in a significant increase in tumor pO 2 at 72-120 h post irradiation. The tumors irradiated with a second dose of 10 Gy at 24 h, when the tumors were oxygenated, had a significant increase in tumor doubling times (DTs), as compared to tumors treated at 48 h when they were hypoxic (p 2 repeatedly during fractionated schemes to optimize radiotherapeutic outcome. This technique could also be used to identify responsive and non-responsive tumors, which will facilitate the design of other therapeutic approaches for non-responsive tumors at early time points during the course of therapy.

  19. Long-term repeatability of the skin prick test is high when supported by history or allergen-sensitivity tests

    DEFF Research Database (Denmark)

    Bødtger, Uffe; Jacobsen, C R; Poulsen, L K

    2003-01-01

    subjects. An SPT was positive when > or =3 mm, and repeatable if either persistently positive or negative. Clinical sensitivity to birch pollen was used as model for inhalation allergy, and was investigated at inclusion and at study termination by challenge tests, intradermal test, titrated SPT and Ig......E measurements. Birch pollen symptoms were confirmed in diaries. RESULTS: The repeatability of a positive SPT was 67%, increasing significantly to 100% when supported by the history. When not supported by history, the presence of specific IgE was significantly associated with a repeatable SPT. Allergen....... CONCLUSION: SPT changes are clinically relevant. Further studies using other allergens are needed. Long-term repeatability of SPT is high in the presence of a supportive history....

  20. The role of TRAIL in fatigue induced by repeated stress from radiotherapy.

    Science.gov (United States)

    Feng, Li Rebekah; Suy, Simeng; Collins, Sean P; Saligan, Leorey N

    2017-08-01

    Fatigue is one of the most common and debilitating side effects of cancer and cancer treatment, and yet its etiology remains elusive. The goal of this study is to understand the role of chronic inflammation in fatigue following repeated stress from radiotherapy. Fatigue and non-fatigue categories were assessed using ≥ 3-point change in Functional Assessment of Cancer Therapy-Fatigue questionnaire (FACT-F) administered to participants at baseline/before radiotherapy and one year post-radiotherapy. Whole genome microarray and cytokine multiplex panel were used to examine fatigue-related transcriptome and serum cytokine changes, respectively. The study included 86 subjects (discovery phase n = 40, validation phase n = 46). The sample in the discovery phase included men with prostate cancer scheduled to receive external-beam radiotherapy. A panel of 48 cytokines were measured and the significantly changed cytokine found in the discovery phase was validated using sera from a separate cohort of men two years after completing radiotherapy for prostate cancer at a different institution. Effects of the significantly changed cytokine on cell viability was quantified using the MTT assay. During the discovery phase, tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) and TRAIL decoy receptor, TNFRSF10C (TRAIL-R3), were significantly upregulated in fatigued (≥3-point decrease from baseline to 1yr-post radiotherapy) subjects (n = 15). In the validation phase, TRAIL correlated with fatigue scores 2yrs post-radiotherapy. TRAIL caused selective cytotoxicity in neuronal cells, but not in microglial and muscle cells, in vitro. Late-onset inflammation directed by TRAIL may play a role in fatigue pathogenesis post-repeated stress from irradiation. Published by Elsevier Ltd.

  1. Repeated Gene Transfection Impairs the Engraftment of Transplanted Porcine Neonatal Pancreatic Cells

    Directory of Open Access Journals (Sweden)

    Min Koo Seo

    2011-02-01

    Full Text Available BackgroundPreviously, we reported that neonatal porcine pancreatic cells transfected with hepatocyte growth factor (HGF gene in an Epstein-Barr virus (EBV-based plasmid (pEBVHGF showed improved proliferation and differentiation compared to those of the control. In this study, we examined if pancreatic cells transfected repeatedly with pEBVHGF can be successfully grafted to control blood glucose in a diabetes mouse model.MethodsNeonatal porcine pancreatic cells were cultured as a monolayer and were transfected with pEBVHGF every other day for a total of three transfections. The transfected pancreatic cells were re-aggregated and transplanted into kidney capsules of diabetic nude mice or normal nude mice. Blood glucose level and body weight were measured every other day after transplantation. The engraftment of the transplanted cells and differentiation into beta cells were assessed using immunohistochemistry.ResultsRe-aggregation of the pancreatic cells before transplantation improved engraftment of the cells and facilitated neovascularization of the graft. Right before transplantation, pancreatic cells that were transfected with pEBVHGF and then re-aggregated showed ductal cell marker expression. However, ductal cells disappeared and the cells underwent fibrosis in a diabetes mouse model two to five weeks after transplantation; these mice also did not show controlled blood glucose levels. Furthermore, pancreatic cells transplanted into nude mice with normal blood glucose showed poor graft survival regardless of the type of transfected plasmid (pCEP4, pHGF, or pEBVHGF.ConclusionFor clinical application of transfected neonatal porcine pancreatic cells, further studies are required to develop methods of overcoming the damage for the cells caused by repeated transfection and to re-aggregate them into islet-like structures.

  2. Effects of acute or repeated paroxetine and fluoxetine treatment on affective behavior in male and female adolescent rats

    Science.gov (United States)

    Amodeo, Leslie R.; Greenfield, Venuz Y.; Humphrey, Danielle E.; Varela, Veronica; Pipkin, Joseph A.; Eaton, Shannon E.; Johnson, Jelesa D.; Plant, Christopher P.; Harmony, Zachary R.; Wang, Li; Crawford, Cynthia A.

    2015-01-01

    Rationale The SSRI antidepressant fluoxetine is one of the few drugs that is effective at treating depression in adolescent humans. In contrast, the SSRI paroxetine has limited efficacy and is more at risk for inducing suicidal behavior. Objective The purpose of the present study was to more fully characterize the differential actions of paroxetine and fluoxetine. Methods In Experiment 1, male and female rats were injected with paroxetine (2.5 or 10 mg/kg), fluoxetine (10 mg/kg), or vehicle for 10 days starting on postnatal day (PD) 35, and affective behaviors were assessed using sucrose preference and elevated plus maze tasks. A separate set of rats were used to examine monoamine levels. In Experiment 2, rats were injected with paroxetine (2.5, 5 or 10 mg/kg), fluoxetine (5, 10 or 20 mg/kg), or vehicle during the same time frame as Experiment 1 and anxiety-like behaviors were measured using elevated plus maze, light/dark box, and acoustic startle. Results Repeated SSRI treatment failed to alter sucrose preference, although both paroxetine and fluoxetine reduced time spent in the open arms of the elevated plus maze and light compartment of the light/dark box. Paroxetine, but not fluoxetine, enhanced acoustic startle and interfered with habituation. Serotonin turnover was decreased by both acute and repeated fluoxetine treatment but unaltered by paroxetine administration. Discussion These results show that repeated treatment with paroxetine and fluoxetine has dissociable actions in adolescent rats. In particular, paroxetine, but not fluoxetine, increases acoustic startle at low doses and may increase sensitivity to environmental stressors. PMID:26141193

  3. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  4. Repeatability of chemical-shift-encoded water-fat MRI and diffusion-tensor imaging in lower extremity muscles in children.

    Science.gov (United States)

    Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente

    2014-06-01

    The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.

  5. Repeated exposure to conditioned fear stress increases anxiety and delays sleep recovery following exposure to an acute traumatic stressor

    Directory of Open Access Journals (Sweden)

    Benjamin N Greenwood

    2014-10-01

    Full Text Available Repeated stressor exposure can sensitize physiological responses to novel stressors and facilitate the development of stress-related psychiatric disorders including anxiety. Disruptions in diurnal rhythms of sleep-wake behavior accompany stress-related psychiatric disorders and could contribute to their development. Complex stressors that include fear-eliciting stimuli can be a component of repeated stress experienced by humans, but whether exposure to repeated fear can prime the development of anxiety and sleep disturbances is unknown. In the current study, adult male F344 rats were exposed to either control conditions or repeated contextual fear conditioning for 22 days followed by exposure to either no, mild (10, or severe (100 acute uncontrollable tail shock stress. Exposure to acute stress produced anxiety-like behavior as measured by a reduction in juvenile social exploration and exaggerated shock-elicited freezing in a novel context. Prior exposure to repeated fear enhanced anxiety-like behavior as measured by shock-elicited freezing, but did not alter social exploratory behavior. The potentiation of anxiety produced by prior repeated fear was temporary; exaggerated fear was present 1 day but not 4 days following acute stress. Interestingly, exposure to acute stress reduced REM and NREM sleep during the hours immediately following acute stress. This initial reduction in sleep was followed by robust REM rebound and diurnal rhythm flattening of sleep / wake behavior. Prior repeated fear extended the acute stress-induced REM and NREM sleep loss, impaired REM rebound, and prolonged the flattening of the diurnal rhythm of NREM sleep following acute stressor exposure. These data suggest that impaired recovery of sleep / wake behavior following acute stress could contribute to the mechanisms by which a history of prior repeated stress increases vulnerability to subsequent novel stressors and stress-related disorders.

  6. Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lecler, Augustin [Fondation Ophtalmologique Adolphe de Rothschild, Department of Radiology, Paris (France); Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Savatovsky, Julien; Sadik, Jean-Claude; Charbonneau, Frederique; Berges, Olivier [Fondation Ophtalmologique Adolphe de Rothschild, Department of Radiology, Paris (France); Balvay, Daniel [Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Zmuda, Mathieu; Galatoire, Olivier [Fondation Ophtalmologique Adolphe de Rothschild, Department of Orbitopalpebral Surgery, Paris (France); Picard, Herve [Fondation Ophtalmologique Adolphe de Rothschild, Clinical Research Unit, Paris (France); Fournier, Laure [Cardiovascular Research Centre - PARCC, Universite Paris Descartes Sorbonne Paris Cite, INSERM UMR-S970, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Assistance Publique-Hopitaux de Paris, Hopital Europeen Georges Pompidou, Radiology Department, Paris (France)

    2017-12-15

    To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit. From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm{sup 2}) at 3.0T. Two readers independently delineated regions of interest in an orbital mass and in different intra-orbital and extra-orbital structures. Short-term test-retest repeatability and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CV) and Bland-Altman limits of agreements (BA-LA). Test-retest repeatability of IVIM parameters in the orbital mass was satisfactory for ADC and D (mean CV 12% and 14%, ICC 95% and 93%), poor for f and D*(means CV 43% and 110%, ICC 90% and 65%). Inter-observer repeatability agreement was almost perfect in the orbital mass for all the IVIM parameters (ICC = 95%, 93%, 94% and 90% for ADC, D, f and D*, respectively). IVIM appeared to be a robust tool to measure D in orbital lesions with good repeatability, but this approach showed a poor repeatability of f and D*. (orig.)

  7. Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions

    International Nuclear Information System (INIS)

    Lecler, Augustin; Savatovsky, Julien; Sadik, Jean-Claude; Charbonneau, Frederique; Berges, Olivier; Balvay, Daniel; Zmuda, Mathieu; Galatoire, Olivier; Picard, Herve; Fournier, Laure

    2017-01-01

    To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit. From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm 2 ) at 3.0T. Two readers independently delineated regions of interest in an orbital mass and in different intra-orbital and extra-orbital structures. Short-term test-retest repeatability and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CV) and Bland-Altman limits of agreements (BA-LA). Test-retest repeatability of IVIM parameters in the orbital mass was satisfactory for ADC and D (mean CV 12% and 14%, ICC 95% and 93%), poor for f and D*(means CV 43% and 110%, ICC 90% and 65%). Inter-observer repeatability agreement was almost perfect in the orbital mass for all the IVIM parameters (ICC = 95%, 93%, 94% and 90% for ADC, D, f and D*, respectively). IVIM appeared to be a robust tool to measure D in orbital lesions with good repeatability, but this approach showed a poor repeatability of f and D*. (orig.)

  8. ATXN2 trinucleotide repeat length correlates with risk of ALS.

    Science.gov (United States)

    Sproviero, William; Shatunov, Aleksey; Stahl, Daniel; Shoai, Maryam; van Rheenen, Wouter; Jones, Ashley R; Al-Sarraj, Safa; Andersen, Peter M; Bonini, Nancy M; Conforti, Francesca L; Van Damme, Philip; Daoud, Hussein; Del Mar Amador, Maria; Fogh, Isabella; Forzan, Monica; Gaastra, Ben; Gellera, Cinzia; Gitler, Aaron D; Hardy, John; Fratta, Pietro; La Bella, Vincenzo; Le Ber, Isabelle; Van Langenhove, Tim; Lattante, Serena; Lee, Yi-Chung; Malaspina, Andrea; Meininger, Vincent; Millecamps, Stéphanie; Orrell, Richard; Rademakers, Rosa; Robberecht, Wim; Rouleau, Guy; Ross, Owen A; Salachas, Francois; Sidle, Katie; Smith, Bradley N; Soong, Bing-Wen; Sorarù, Gianni; Stevanin, Giovanni; Kabashi, Edor; Troakes, Claire; van Broeckhoven, Christine; Veldink, Jan H; van den Berg, Leonard H; Shaw, Christopher E; Powell, John F; Al-Chalabi, Ammar

    2017-03-01

    We investigated a CAG trinucleotide repeat expansion in the ATXN2 gene in amyotrophic lateral sclerosis (ALS). Two new case-control studies, a British dataset of 1474 ALS cases and 567 controls, and a Dutch dataset of 1328 ALS cases and 691 controls were analyzed. In addition, to increase power, we systematically searched PubMed for case-control studies published after 1 August 2010 that investigated the association between ATXN2 intermediate repeats and ALS. We conducted a meta-analysis of the new and existing studies for the relative risks of ATXN2 intermediate repeat alleles of between 24 and 34 CAG trinucleotide repeats and ALS. There was an overall increased risk of ALS for those carrying intermediate sized trinucleotide repeat alleles (odds ratio 3.06 [95% confidence interval 2.37-3.94]; p = 6 × 10 -18 ), with an exponential relationship between repeat length and ALS risk for alleles of 29-32 repeats (R 2  = 0.91, p = 0.0002). No relationship was seen for repeat length and age of onset or survival. In contrast to trinucleotide repeat diseases, intermediate ATXN2 trinucleotide repeat expansion in ALS does not predict age of onset but does predict disease risk. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  9. Sedation for pediatric neuroradiological examinations. Retrospective study of 160 cases

    International Nuclear Information System (INIS)

    Shose, Yoshiteru; Oi, Shizuo

    1995-01-01

    A retrospective study of 160 pediatric neuroradiological examinations was conducted to determine the efficacy and safety of two sedation regimens (figs. 1, 2). For CT purposes, 150 patients (fig. 3) were orally given monosodium trichlorethyl phosphate syrup (100 mg/kg, with repeat 50 mg/kg if necessary), and for cerebral angiography, 15 patients (fig. 4) were intramuscularly administered a modified D.P.T. cocktail (pentazocine, chlorpromadine, promethazine). Failure rate in the oral syrup group was 6%, and in the D.P.T. group 6.7%. Diagnostic-quality images were obtained in 99.3% and 100%, respectively, of the two groups. There were neither mortality nor significant complications (table 3). It was concluded that each method had proved acceptably safe and effective, and that measures can be taken to further decrease complications and sedation failures. (author)

  10. Comparing a single case to a control group - Applying linear mixed effects models to repeated measures data.

    Science.gov (United States)

    Huber, Stefan; Klein, Elise; Moeller, Korbinian; Willmes, Klaus

    2015-10-01

    In neuropsychological research, single-cases are often compared with a small control sample. Crawford and colleagues developed inferential methods (i.e., the modified t-test) for such a research design. In the present article, we suggest an extension of the methods of Crawford and colleagues employing linear mixed models (LMM). We first show that a t-test for the significance of a dummy coded predictor variable in a linear regression is equivalent to the modified t-test of Crawford and colleagues. As an extension to this idea, we then generalized the modified t-test to repeated measures data by using LMMs to compare the performance difference in two conditions observed in a single participant to that of a small control group. The performance of LMMs regarding Type I error rates and statistical power were tested based on Monte-Carlo simulations. We found that starting with about 15-20 participants in the control sample Type I error rates were close to the nominal Type I error rate using the Satterthwaite approximation for the degrees of freedom. Moreover, statistical power was acceptable. Therefore, we conclude that LMMs can be applied successfully to statistically evaluate performance differences between a single-case and a control sample. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. RTEL1 Inhibits Trinucleotide Repeat Expansions and Fragility

    OpenAIRE

    Aisling Frizzell; Jennifer H.G. Nguyen; Mark I.R. Petalcorin; Katherine D. Turner; Simon J. Boulton; Catherine H. Freudenreich; Robert S. Lahue

    2014-01-01

    SUMMARY Human RTEL1 is an essential, multifunctional helicase that maintains telomeres, regulates homologous recombination, and helps prevent bone marrow failure. Here, we show that RTEL1 also blocks trinucleotide repeat expansions, the causal mutation for 17 neurological diseases. Increased expansion frequencies of (CTG·CAG) repeats occurred in human cells following knockdown of RTEL1, but not the alternative helicase Fbh1, and purified RTEL1 efficiently unwound triplet repeat hairpins in vi...

  12. Germ-line CAG repeat instability causes extreme CAG repeat expansion with infantile-onset spinocerebellar ataxia type 2

    DEFF Research Database (Denmark)

    Vinther-Jensen, Tua; Ek, Jakob; Duno, Morten

    2013-01-01

    The spinocerebellar ataxias (SCA) are a genetically and clinically heterogeneous group of diseases, characterized by dominant inheritance, progressive cerebellar ataxia and diverse extracerebellar symptoms. A subgroup of the ataxias is caused by unstable CAG-repeat expansions in their respective ...... of paternal germ-line repeat sequence instability of the expanded SCA2 locus.European Journal of Human Genetics advance online publication, 10 October 2012; doi:10.1038/ejhg.2012.231....

  13. Acute effects of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion.

    Science.gov (United States)

    Kobayashi, Ryota; Hashimoto, Yuto; Hatakeyama, Hiroyuki; Okamoto, Takanobu

    2018-03-22

    The aim of this study was to investigate the acute repeated bouts of aerobic exercise decrease leg arterial stiffness. However, the influence of repeated bouts of aerobic exercise on arterial stiffness after glucose ingestion is unknown. The present study investigates the acute effects of repeated bouts of aerobic exercise on arterial stiffness after the 75-g oral glucose tolerance test (OGTT). Ten healthy young men (age, 23.2 ± 0.9 years) performed repeated bouts of aerobic exercise trial (RE, 65% peak oxygen uptake; two 15 min bouts of cycling performed 20 min apart) and control trial (CON, seated and resting in a quiet room) at 80 min before the 75-g OGTT on separate days in a randomized, controlled crossover fashion. Carotid-femoral (aortic) and femoral-ankle (leg) pulse wave velocity, carotid augmentation index, brachial and ankle blood pressure, heart rate and blood glucose and insulin levels were measured before (baseline) and 30, 60 and 120 min after the 75-g OGTT. Leg pulse wave velocity, ankle systolic blood pressure and blood glucose levels increased from baseline after the 75-g OGTT in the CON trial, but not in the RE trial. The present findings indicate that acute repeated bouts of aerobic exercise before glucose ingestion suppress increases in leg arterial stiffness following glucose ingestion. RE trial repeated bouts of aerobic exercise trial; CON trial control trial; BG blood glucose; VO 2peak peak oxygen uptake; PWV Pulse wave velocity; AIx carotid augmentation index; BP blood pressure; HR heart rate; CVs coefficients of variation; RPE Ratings of perceived exertion; SE standard error.

  14. Performance Comparisons of Improved Regular Repeat Accumulate (RA and Irregular Repeat Accumulate (IRA Turbo Decoding

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulkadhim Hamad

    2017-08-01

    Full Text Available In this paper, different techniques are used to improve the turbo decoding of regular repeat accumulate (RA and irregular repeat accumulate (IRA codes. The adaptive scaling of a-posteriori information produced by Soft-output Viterbi decoder (SOVA is proposed. The encoded pilots are another scheme that applied for short length RA codes. This work also suggests a simple and a fast method to generate a random interleaver having a free 4 cycle Tanner graph. Progressive edge growth algorithm (PEG is also studied and simulated to create the Tanner graphs which have a great girth.

  15. Behavioral sensitization after repeated formaldehyde exposure in rats.

    Science.gov (United States)

    Sorg, B A; Hochstatter, T

    1999-01-01

    Multiple chemical sensitivity (MCS) is a phenomenon whereby individuals report increased sensitivity to chemicals in the environment, and attribute their sensitivities to prior exposure to the same or often structurally unrelated chemicals. A leading hypothesis suggests that MCS is akin to behavioral sensitization observed in rodents after repeated exposure to drugs of abuse or environmental stressors. Sensitization occurring within limbic circuitry of the central nervous system (CNS) may explain the multisymptom complaints in individuals with MCS. The present studies represent the continuing development of an animal model for MCS, the basis of which is the CNS sensitization hypothesis. Three behaviors were assessed in rats repeatedly exposed to formaldehyde (Form) inhalation. In the first series of experiments, rats were given high-dose Form exposure (11 parts per million [ppm]; 1 h/day x 7 days) or low-dose Form exposure (1 ppm; either 1 h/day x 7 days or 1 h/day x 5 days/week x 4 weeks). Within a few days after discontinuing daily Form, cocaine-induced locomotor activity was elevated after high-dose Form or 20 days of low-dose Form inhalation. Approximately 1 month later, cocaine-induced locomotor activity remained significantly elevated in the 20-day Form-exposed rats. The second experiment assessed whether prior exposure to Form (20 days, as above) would alter the ability to condition to an odor (orange oil) paired with footshock. The results suggested a tendency to increase the conditioned fear response to the odor but not the context of the footshock box, and a decreased tendency to extinguish the conditioned fear response to odor. The third experiment examined whether CNS sensitization to daily cocaine or stress would alter subsequent avoidance responding to odor (Form). Daily cocaine significantly elevated approach responses to Form, while daily stress pretreatment produced a trend in the opposite direction, producing greater avoidance of Form. Preliminary

  16. ALTERED HIPPOCAMPAL NEUROGENESIS AND AMYGDALAR NEURONAL ACTIVITY IN ADULT MICE WITH REPEATED EXPERIENCE OF AGGRESSION

    Directory of Open Access Journals (Sweden)

    Dmitriy eSmagin

    2015-12-01

    Full Text Available The repeated experience of winning in a social conflict setting elevates levels of aggression and may lead to violent behavioral patterns. Here we use a paradigm of repeated aggression and fighting deprivation to examine changes in behavior, neurogenesis, and neuronal activity in mice with positive fighting experience. We show that for males, repeated positive fighting experience induces persistent demonstration of aggression and stereotypic behaviors in daily agonistic interactions, enhances aggressive motivation, and elevates levels of anxiety. When winning males are deprived of opportunities to engage in further fights, they demonstrate increased levels of aggressiveness. Positive fighting experience results in increased levels of progenitor cell proliferation and production of young neurons in the hippocampus. This increase is not diminished after a fighting deprivation period. Furthermore, repeated winning experience decreases the number of activated (c-fos positive cells in the basolateral amygdala and increases the number of activated cells in the hippocampus; a subsequent no-fight period restores the number of c-fos-positive cells. Our results indicate that extended positive fighting experience in a social conflict heightens aggression, increases proliferation of neuronal progenitors and production of young neurons in the hippocampus, and decreases neuronal activity in the amygdala; these changes can be modified by depriving the winners of the opportunity for further fights.

  17. Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data

    Science.gov (United States)

    Bao, FangJun; Wang, JunJie; Huang, JinHai; Yu, Ye; Deng, ManLi; Li, LinNa; Yu, AYong; Wang, QinMei; Davey, Pinakin Gunvant; Elsheikh, Ahmed

    2015-01-01

    Purpose To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data. Methods Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm. The method simultaneously considered the anterior and posterior maps taken for the same eye since they were assumed to have the same set of misalignment components. A new parameter, named Combined Misalignment parameter (CM), has been developed to combine the effect of all six misalignment components on topography data and so enable study of the association between misalignment and the data repeatability test results. Results The repeatability tests resulted in average root mean square (RMS) differences in elevation data of 8.46±2.75 μm before ICP map matching when simultaneously considering anterior and posterior surfaces. With map matching and misalignment correction, the differences decreased to 7.28±2.58 μm (P = 0.00). When applied to only the anterior maps, misalignment correction led to a more pronounced reduction in elevation data differences from 4.58±1.84 μm to 2.97±1.29 μm (P = 0.00). CM was found to be associated with the repeatability error (P = 0.00), with posterior maps being responsible for most of the error due to their relatively lower accuracy compared to anterior maps

  18. Aging and repeated thought suppression success.

    Directory of Open Access Journals (Sweden)

    Ann E Lambert

    Full Text Available Intrusive thoughts and attempts to suppress them are common, but while suppression may be effective in the short-term, it can increase thought recurrence in the long-term. Because intentional suppression involves controlled processing, and many aspects of controlled processing decline with age, age differences in thought suppression outcomes may emerge, especially over repeated thought suppression attempts as cognitive resources are expended. Using multilevel modeling, we examined age differences in reactions to thought suppression attempts across four thought suppression sequences in 40 older and 42 younger adults. As expected, age differences were more prevalent during suppression than during free monitoring periods, with younger adults indicating longer, more frequent thought recurrences and greater suppression difficulty. Further, younger adults' thought suppression outcomes changed over time, while trajectories for older adults' were relatively stable. Results are discussed in terms of older adults' reduced thought recurrence, which was potentially afforded by age-related changes in reactive control and distractibility.

  19. Analysis of CR1 Repeats in the Zebra Finch Genome

    Directory of Open Access Journals (Sweden)

    George E. Liu

    2013-06-01

    Full Text Available Most bird species have smaller genomes and fewer repeats than mammals. Chicken Repeat 1 (CR1 repeat is one of the most abundant families of repeats, ranging from ~133,000 to ~187,000 copies accounting for ~50 to ~80% of the interspersed repeats in the zebra finch and chicken genomes, respectively. CR1 repeats are believed to have arisen from the retrotransposition of a small number of master elements, which gave rise to multiple CR1 subfamilies in the chicken. In this study, we performed a global assessment of the divergence distributions, phylogenies, and consensus sequences of CR1 repeats in the zebra finch genome. We identified and validated 34 CR1 subfamilies and further analyzed the correlation between these subfamilies. We also discovered 4 novel lineage-specific CR1 subfamilies in the zebra finch when compared to the chicken genome. We built various evolutionary trees of these subfamilies and concluded that CR1 repeats may play an important role in reshaping the structure of bird genomes.

  20. Large Polyglutamine Repeats Cause Muscle Degeneration in SCA17 Mice

    Directory of Open Access Journals (Sweden)

    Shanshan Huang

    2015-10-01

    Full Text Available In polyglutamine (polyQ diseases, large polyQ repeats cause juvenile cases with different symptoms than those of adult-onset patients, who carry smaller expanded polyQ repeats. The mechanisms behind the differential pathology mediated by different polyQ repeat lengths remain unknown. By studying knockin mouse models of spinal cerebellar ataxia-17 (SCA17, we found that a large polyQ (105 glutamines in the TATA-box-binding protein (TBP preferentially causes muscle degeneration and reduces the expression of muscle-specific genes. Direct expression of TBP with different polyQ repeats in mouse muscle revealed that muscle degeneration is mediated only by the large polyQ repeats. Different polyQ repeats differentially alter TBP’s interaction with neuronal and muscle-specific transcription factors. As a result, the large polyQ repeat decreases the association of MyoD with TBP and DNA promoters. Our findings suggest that specific alterations in protein interactions by large polyQ repeats may account for the unique pathology in juvenile polyQ diseases.