WorldWideScience

Sample records for repeated measures crossover

  1. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  2. Measurement-based quantum repeaters

    CERN Document Server

    Zwerger, M; Briegel, H J

    2012-01-01

    We introduce measurement-based quantum repeaters, where small-scale measurement-based quantum processors are used to perform entanglement purification and entanglement swapping in a long-range quantum communication protocol. In the scheme, pre-prepared entangled states stored at intermediate repeater stations are coupled with incoming photons by simple Bell-measurements, without the need of performing additional quantum gates or measurements. We show how to construct the required resource states, and how to minimize their size. We analyze the performance of the scheme under noise and imperfections, with focus on small-scale implementations involving entangled states of few qubits. We find measurement-based purification protocols with significantly improved noise thresholds. Furthermore we show that already resource states of small size suffice to significantly increase the maximal communication distance. We also discuss possible advantages of our scheme for different set-ups.

  3. No Improved Performance With Repeated-Sprint Training in Hypoxia Versus Normoxia: A Double-Blind and Crossover Study.

    Science.gov (United States)

    Montero, David; Lundby, Carsten

    2017-02-01

    Few recent studies indicate that short-term repeated-sprint (RS) training in hypoxia (RSH) improves RS performance compared with identical training under normoxic conditions (RSN) in endurance-trained subjects. To determine the effects of RSH against RSN on RS performance under normoxic and moderate hypoxic conditions, using a randomized, doubleblind, crossover experimental design. Fifteen endurance-trained male subjects (age 25 ± 4 y) performed 4 wk of RS training (3 sessions/wk) in normobaric hypoxia (RSH, FiO2 = 13.8%) and normoxia (RSN, FiO2 = 20.9%) in a crossover manner. Before and after completion of training, RS tests were performed on a cycle ergometer with no prior exercise (RSNE), after an incremental exercise test (RSIE), and after a time-trial test (RSTT) in normoxia and hypoxia. Peak power outputs at the incremental exercise test and time-trial performance were unaltered by RSH in normoxia and hypoxia. RS performance was generally enhanced by RSH, as well as RSN, but there were no additional effects of RSH over RSN on peak and mean sprint power output and the number of repeated sprints performed in the RSNE, RSIE, and RSTT trials under normoxic and hypoxic conditions. The present double-blind crossover study indicates that RSH does not improve RS performance compared with RSN in normoxic and hypoxic conditions in endurance-trained subjects. Therefore, caution should be exercised when proposing RSH as an advantageous method to improve exercise performance.

  4. Crossover difference data records (XDR) from GEOSAT Geodetic Mission (GM) and Exact Repeat Mission (ERM) data from 01 April 1985 to 07 November 1987 (NCEI Accession 9100053)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Crossover difference data records (XDRs) from the GEOSAT Geodetic Mission (GM) and Exact Repeat Mission (ERM) for the time period April 1, 1985 to November 7, 1987....

  5. Crossover difference data records (XDR) from GEOSAT Geodetic Mission (GM) and Exact Repeat Mission (ERM) data from 01 January 1985 to 31 December 1989 (NODC Accession 9000068)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Crossover difference data records (XDRs) from the GEOSAT Geodetic Mission (GM) and Exact Repeat Mission (ERM) for the time period of January 01, 1985 to December 31,...

  6. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...

  7. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  8. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  9. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, Joris; Klugkist, I.G.; Schoot, Rens van de; Meeus, W.H.J.; Selfhout, Maarten; Hoijtink, Herbert

    2010-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between

  10. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, J.|info:eu-repo/dai/nl/304823031; Klugkist, I.G.|info:eu-repo/dai/nl/27330089X; Van de Schoot, R.|info:eu-repo/dai/nl/304833207; Meeus, W.H.J.|info:eu-repo/dai/nl/070442215; van Zalk, M.H.W.|info:eu-repo/dai/nl/304836214; Hoijtink, H.J.A.|info:eu-repo/dai/nl/075184427

    2009-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between groups,

  11. Measuring Meiotic Crossovers via Multi-Locus Genotyping of Single Pollen Grains in Barley.

    Directory of Open Access Journals (Sweden)

    Steven Dreissig

    Full Text Available The detection of meiotic crossovers in crop plants currently relies on scoring DNA markers in a segregating population or cytological visualization. We investigated the feasibility of using flow-sorted haploid nuclei, Phi29 DNA polymerase-based whole-genome-amplification (WGA and multi-locus KASP-genotyping to measure meiotic crossovers in individual barley pollen grains. To demonstrate the proof of concept, we used 24 gene-based physically mapped single nucleotide polymorphisms to genotype the WGA products of 50 single pollen nuclei. The number of crossovers per chromosome, recombination frequencies along chromosome 3H and segregation distortion were analysed and compared to a doubled haploid (DH population of the same genotype. The number of crossovers and chromosome wide recombination frequencies show that this approach is able to produce results that resemble those obtained from other methods in a biologically meaningful way. Only the segregation distortion was found to be lower in the pollen population than in DH plants.

  12. Analysis of repeated outcome measures from longitudinal studies

    Institute of Scientific and Technical Information of China (English)

    Yuanjia WANG; Naihua DUAN

    2011-01-01

    @@ In many clinical studies repeated measurements of an outcome are collected over time.For example,in an 8-week study of treatment for obsessive compulsive disorder,the severity of the disorder may be measured weekly using the Yale-Brown-Obsessive-Compulsive-Disorder-Scale (YBOCS).For each study participant who completes the study,there will be nine repeated measures of YBOCS (a baseline assessment plus eight assessments during the course of treatment).Such a study in which participants are followed and measured repeatedly over time is called a longitudinal study and the resulting data are called longitudinal data.

  13. Airborne Repeat Pass Interferometry for Deformation Measurements

    NARCIS (Netherlands)

    Groot, J.; Otten, M.; Halsema, E. van

    2000-01-01

    In ground engineering the need for deformation measurements is urgent. SAR interferometry can be used to measure small (sub-wavelength) deformations. An experiment to investigate this for dike deformations was set up, using the C-band SAR system PHARUS (PHased ARray Universal SAR). This paper descri

  14. Discriminant analysis for repeated measures data: a review

    Directory of Open Access Journals (Sweden)

    Lisa Lix

    2010-09-01

    Full Text Available Discriminant analysis (DA encompasses procedures for classifying observations into groups (i.e., predictive discriminative analysis and describing the relative importance of variables for distinguishing amongst groups (i.e., descriptive discriminative analysis. In recent years, a number of developments have occurred in DA procedures for the analysis of data from repeated measures designs. Specifically, DA procedures have been developed for repeated measures data characterized by missing observations and/or unbalanced measurement occasions, as well as high-dimensional data in which measurements are collected repeatedly on two or more variables. This paper reviews the literature on DA procedures for univariate and multivariate repeated measures data, focusing on covariance pattern and linear mixed-effects models. A numeric example illustrates their implementation using SAS software.

  15. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  16. Correct use of repeated measures analysis of variance.

    Science.gov (United States)

    Park, Eunsik; Cho, Meehye; Ki, Chang-Seok

    2009-02-01

    In biomedical research, researchers frequently use statistical procedures such as the t-test, standard analysis of variance (ANOVA), or the repeated measures ANOVA to compare means between the groups of interest. There are frequently some misuses in applying these procedures since the conditions of the experiments or statistical assumptions necessary to apply these procedures are not fully taken into consideration. In this paper, we demonstrate the correct use of repeated measures ANOVA to prevent or minimize ethical or scientific problems due to its misuse. We also describe the appropriate use of multiple comparison tests for follow-up analysis in repeated measures ANOVA. Finally, we demonstrate the use of repeated measures ANOVA by using real data and the statistical software package SPSS (SPSS Inc., USA).

  17. Repeated measurement sampling in genetic association analysis with genotyping errors.

    Science.gov (United States)

    Lai, Renzhen; Zhang, Hong; Yang, Yaning

    2007-02-01

    Genotype misclassification occurs frequently in human genetic association studies. When cases and controls are subject to the same misclassification model, Pearson's chi-square test has the correct type I error but may lose power. Most current methods adjusting for genotyping errors assume that the misclassification model is known a priori or can be assessed by a gold standard instrument. But in practical applications, the misclassification probabilities may not be completely known or the gold standard method can be too costly to be available. The repeated measurement design provides an alternative approach for identifying misclassification probabilities. With this design, a proportion of the subjects are measured repeatedly (five or more repeats) for the genotypes when the error model is completely unknown. We investigate the applications of the repeated measurement method in genetic association analysis. Cost-effectiveness study shows that if the phenotyping-to-genotyping cost ratio or the misclassification rates are relatively large, the repeat sampling can gain power over the regular case-control design. We also show that the power gain is not sensitive to the genetic model, genetic relative risk and the population high-risk allele frequency, all of which are typically important ingredients in association studies. An important implication of this result is that whatever the genetic factors are, the repeated measurement method can be applied if the genotyping errors must be accounted for or the phenotyping cost is high.

  18. Assessing agreement with repeated measures for random observers.

    Science.gov (United States)

    Chen, Chia-Cheng; Barnhart, Huiman X

    2011-12-30

    Agreement studies are often concerned with assessing whether different observers for measuring responses on the same subject or sample can produce similar results. The concordance correlation coefficient (CCC) is a popular index for assessing the closeness among observers for quantitative measurements. Usually, the CCC is used for data without and with replications based on subject and observer effects only. However, we cannot use this methodology if repeated measurements rather than replications are collected. Although there exist some CCC-type indices for assessing agreement with repeated measurements, there is no CCC for random observers and random time points. In this paper, we propose a new CCC for repeated measures where both observers and time points are treated as random effects. A simulation study demonstrates our proposed methodology, and we use vertebral body data and image data for illustrations.

  19. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  20. Measurement and repeatability of interrupter resistance in unsedated newborn infants.

    Science.gov (United States)

    Adams, A M; Olden, C; Wertheim, D; Ives, A; Bridge, P D; Lenton, J; Seddon, P

    2009-12-01

    Interrupter resistance (R(int)) is a useful measure of airway caliber in young children, but has not been well characterized in infants-in whom there are concerns about the accurate measurement of driving pressure. This study aimed to assess the feasibility and repeatability of measuring R(int) in unsedated newborn infants, and to explore alternative algorithms for calculating driving pressure. R(int) measurement was attempted in 28 healthy term newborn infants during natural sleep using the MicroRint device. Paired R(int) measurements were achieved in 24 infants, but after screening of waveforms only 15 infants had at least 5 technically acceptable waveforms on both measurements. R(int) values obtained were comparable with reported values for airflow resistance in newborns using other methods. However, the repeatability coefficient (CR) was much higher than reported values in preschool children using standard back-extrapolation algorithms, with CR 2.47 KPa L(-1) sec (unscreened) and 2.93 KPa L(-1) sec (screened). Other algorithms gave only marginally better repeatability, with all CR values over 50% of the mean R(int) value. Using current commercially available equipment, R(int) is too poorly repeatable to be a reliable measurement of airflow resistance in newborn infants. Lower deadspace equipment is needed, but anatomical and physiological factors in the infant are also important.

  1. Modeling repeated measurement data for occupational exposure assessment and epidemiology

    NARCIS (Netherlands)

    Peretz, Chava

    2004-01-01

    Repeated measurements designs, occur frequently in the assessment of exposure to toxic chemicals. This thesis deals with the possibilities of using mixed effects models for occupational exposure assessment and in the analysis of exposure response relationships. The model enables simultaneous estima

  2. Applying the General Linear Model to Repeated Measures Problems.

    Science.gov (United States)

    Pohlmann, John T.; McShane, Michael G.

    The purpose of this paper is to demonstrate the use of the general linear model (GLM) in problems with repeated measures on a dependent variable. Such problems include pretest-posttest designs, multitrial designs, and groups by trials designs. For each of these designs, a GLM analysis is demonstrated wherein full models are formed and restrictions…

  3. Positional Repeatability Measurements Of Stepper Motors At Cryogenic Temperatures

    Science.gov (United States)

    Pompea, Stephen M.; Hall, Michael S.; Bartko, Frank; Houck, James R.

    1983-08-01

    Stepper motors operating at liquid helium temperature have multiple applications in cryogenically-cooled telescopes such as the Shuttle Infrared Telescope Facility (SIRTF). These SIRTF applications include driving cryogen flow valves, operating the Multiple Instrument Chamber (MIC) beam splitter mechanism, and operating filters and grating wheel mechanisms in the scientific instruments. The positional repeatability of the beam splitter drive mechanism is especially critical since it feeds the optical beam to the scien-tific instruments. Despite these important applications, no significant data on the positional repeatability of stepper motors at cryogenic temperatures has been available. Therefore, we conducted a series of measurements to determine the positional repeatability of a modified, off-the-shelf Berger/Lahr stepper motor (model RDM 253/25, step angle 3.6°) which had demonstrated excellent performance in previous endurance testing at LHe temperature. These test results indicated that the positional repeatability of the motor was excellent at all temperatures, with somewhat better performance at cryogenic temperatures. Another important result was that the motor could be repeatedly turned off and on while still accurately retaining its rotor position.

  4. Repeatability of OCT lens thickness measures with age and accommodation.

    Science.gov (United States)

    Doyle, Lesley; Little, Julie-Anne; Saunders, Kathryn J

    2013-12-01

    To investigate crystalline lens thickness (LT) across a range of ages and accommodative demands and to evaluate the repeatability of LT measurements using the Visante Anterior Segment Optical Coherence Tomographer (AS-OCT) (Zeiss Meditec, Germany) under non-cycloplegic conditions. Participants were 98 visually normal adults aged 18-75 years, stratified into age groups of 18-29, 30-39, 40-49, 50-59, and 60-75 years of age. Images of the crystalline lens were taken using the Visante AS-OCT during stimulation of accommodation at demands of 0, 1, 2, 3, 4, 5, and 8 D with accommodative response measured in a subgroup of participants. Images were analyzed and LT measured assuming a refractive index of 1.42. Repeat measures were taken from 86 participants for each accommodative demand at a second visit. The mean unaccommodated LT for all participants was 4.07 ± 0.40 mm. An average increase in LT of 20 μm per year was calculated (linear regression, R² = 0.61, F(1,89) = 143.92, p report the repeatability of LT measures using the Visante AS-OCT in the non-cyclopleged eye. It has also demonstrated the ability of the Visante AS-OCT to detect small changes in lens thickness with accommodation.

  5. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  6. Capturing learning effects on eye movements in repeated measures experiments

    DEFF Research Database (Denmark)

    Bagger, Martin; Orquin, Jacob Lund; Fiedler, Susann

    We propose and illustrate that repeated exposure to stimuli sets increases the size of the saccade amplitudes. Saccadic amplitudes are closely related to the perceptual span and therefore used as a measure for the information intake in an experiment. Studies on expertise have shown that experts...... experiment in which 68 participants made choices between four alternatives with three different between subject conditions varying in presentation format (verbal matrix, a pictorial matrix, and a realistic product representation). The results consistently demonstrate an increase of the saccade amplitude over...... the course of the experiment independent of condition. We conclude by discussing our results in the light of the possible increase of the perceptual span and its implications for the research procedure in eye-tracking experiments with a repeated measurement design....

  7. Role of reciprocal exchange, one-ended invasion crossover and single-strand annealing on inverted and direct repeat recombination in yeast: Different requirements for the RAD1, RAD 10, and RAD52 genes

    Energy Technology Data Exchange (ETDEWEB)

    Prado, F.; Aguilera, A. [Universidad de Sevilla (Spain)

    1995-01-01

    We have constructed novel DNA substrates (one inverted and three direct repeats) based on the same 0.6-kb repeat sequence to study deletions and inversions in Saccharomyces cerevisiae. Spontaneous deletions occur six to eight times more frequently than inversions, irrespective of the distance between the repeats. This difference can be explained by the observation that deletion events can be mediated by a recombination mechanism that can initiate within the intervening sequence of the repeats. Spontaneous and double-strand break (DSB)-induced deletions occur as RAD52-dependent and RAD52-independent events. Those deletion events initiated through a DSB in the unique intervening sequence require the Rad1/Rad10 endonuclease only if the break is distantly located from the flanking DNA repeats. We propose that deletions can occur as three types of recombination events: the conservative RAD52-dependent reciprocal exchange and the nonconservative events, one-ended invasion crossover, and single-strand annealing (SSA). We suggest that one-ended invasion is RAD52 dependent, whereas SSA is RAD52 independent. Whereas deletions, like inversions, occur through reciprocal exchange, deletions can also occur through SSA or one-ended invasion. We propose that the contribution of reciprocal exchange and one-ended invasion crossover vs. SSA events to overall spontaneous deletions is a feature specific for each repeat system, determined by the initiation event and the availability of the Rad52 protein. We discuss the role of the Rad1/Rad10 endonuclease on the initial steps of one-ended invasion crossover and SSA as a function of the location of the initiation event relative to the repeats. We also show that the frequency of recombination between repeats is the same independent of their location (whether on circular plasmids, linear minichromosomes, or natural chromosomes) and have similar RAD52 dependence. 74 refs., 5 figs., 6 tabs.

  8. Measurement of Wave Chaotic Eigenfunctions in the Time-Reversal Symmetry-Breaking Crossover Regime

    CERN Document Server

    Chung, S H; Wu, D H; Bridgewater, A; Anlage, S M; Chung, Seok-Hwan; Gokirmak, Ali; Wu, Dong-Ho; Anlage, Steven M.

    1999-01-01

    We present experimental results on eigenfunctions of a wave chaotic system in the continuous crossover regime between time-reversal symmetric and time-reversal symmetry-broken states. The statistical properties of the eigenfunctions of a two-dimensional microwave resonator are analyzed as a function of an experimentally determined time-reversal symmetry breaking parameter. We test four theories of eigenfunction statistics in the crossover regime. We also find a universal correlation between the one-point and two-point statistical parameters for the crossover eigenfunctions.

  9. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  10. Unitarity, Feedback, Interactions -- Dynamics Emergent from Repeated Measurements

    CERN Document Server

    Altamirano, Natacha; Mann, Robert B; Zych, Magdalena

    2016-01-01

    Motivated by the recent efforts to describe the gravitational interaction as a classical channel arising from continuous quantum measurements, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence (quantum Zeno effect). For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions, generalizing the lower bound of the gravitational example. However, by allowing multipartite measurements, the interactions can be induced with arbitrary low decoherence. Our results have implications for gravity-inspired decoherence models and the simple framework used in the present study can find applications in devising novel quantum control protocols, or quan...

  11. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  12. Quasar Variability Measurements With SDSS Repeated Imaging and POSS Data

    CERN Document Server

    Ivezic, Z; Juric, M; Anderson, S; Hall, P B; Richards, G T; Rockosi, C M; Vanden Berk, Daniel E; Turner, E L; Knapp, G R; Gunn, J E; Schlegel, D J; Strauss, M A; Schneider, D P

    2004-01-01

    We analyze the properties of quasar variability using repeated SDSS imaging data in five UV-to-far red photometric bands, accurate to 0.02 mag, for 13,000 spectroscopically confirmed quasars. The observed time lags span the range from 3 hours to over 3 years, and constrain the quasar variability for rest-frame time lags of up to two years, and at rest-frame wavelengths from 1000 Ang. to 6000 Ang. We demonstrate that 66,000 SDSS measurements of magnitude differences can be described within the measurement noise by a simple function of only three free parameters. The addition of POSS data constrains the long-term behavior of quasar variability and provides evidence for a turn-over in the structure function. This turn-over indicates that the characteristic time scale for optical variability of quasars is of the order 1 year.

  13. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Science.gov (United States)

    Yang, Yuan-Pei; Zhang, Bing

    2017-09-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  14. Coseismic and postseismic velocity changes measured by repeating earthquakes

    Science.gov (United States)

    Schaff, David P.; Beroza, Gregory C.

    2004-10-01

    Repeating earthquakes that rupture approximately the same fault patch and have nearly identical waveforms are a useful tool for measuring temporal changes in wave propagation in the Earth's crust. Since source and path effects are common to all earthquakes in a repeating earthquake sequence (multiplet), differences in their waveforms can be attributed to changes in the characteristics of the medium. We have identified over 20 multiplets containing between 5 and 40 repeating events in the aftershock zones of the 1989 Loma Prieta and 1984 Morgan Hill, California, earthquakes. Postmain shock events reveal delays of phases in the early S wave coda of as much as 0.2 s relative to premain shock events. The delay amounts to a path-averaged coseismic velocity decrease of about 1.5% for P waves and 3.5% for S waves. Since most of the multiplets are aftershocks and follow Omori's law, we have excellent temporal sampling in the immediate postmain shock period. We find that the amplitude of the velocity decrease decays logarithmically in time following the main shock. In some cases it returns to the premain shock values, while in others it does not. Similar results are obtained for the Morgan Hill main shock. Because the fractional change in S wave velocity is greater than the fractional change in P wave velocity, it suggests that the opening or connection of fluid-filled fractures is the underlying cause. The magnitude of the velocity change implies that low effective pressures are present in the source region of the velocity change. Our results suggest that the changes are predominantly near the stations and shallow, but we cannot exclude the possibility that changes occur at greater depth as well. If the variations are shallow, we may be detecting the lingering effects of nonlinearity during main shock strong ground motion. If the variations are deep, it suggests that pore pressures at seismogenic depths are high, which would likely play a key role in the earthquake process.

  15. Two measures of bilingualism in the memories of immigrants and indigenous minorities: crossover memories and codeswitching.

    Science.gov (United States)

    Altman, Carmit

    2015-04-01

    Two indices of bilingualism, crossover memories and codeswitching (CS), were explored in five groups of immigrant (English-Hebrew, Georgian-Hebrew Russian-Hebrew) and indigenous bilinguals (Arabic-Hebrew, Hebrew-English). Participants recalled memories in response to cue words and then were asked to report the language of retrieval and provide a more elaborate narrative. More memories were 'same language' memories, recalled in the language of the experimental session/cue word, but as many as 48 % of the memories were crossovers, i.e. memories reported in a language other than the language of the session/cue word. In an effort to examine the ecological validity of the self-reported language of the memories, the frequency of CS in the elaborated narratives was investigated. For the entire sample, more CS was found for self-reported crossover memories in L2 sessions. In a further analysis of CS in crossover memories, collapsed across L1 and L2 sessions, significant differences emerged between immigrants and indigenous bilinguals. Differences between immigrant and non-immigrant bilinguals are discussed in terms of the role of activation in crossover memories.

  16. Bayesian Concordance Correlation Coefficient with Application to Repeatedly Measured Data

    Directory of Open Access Journals (Sweden)

    Atanu BHATTACHARJEE

    2015-10-01

    Full Text Available Objective: In medical research, Lin's classical concordance correlation coefficient (CCC is frequently applied to evaluate the similarity of the measurements produced by different raters or methods on the same subjects. It is particularly useful for continuous data. The objective of this paper is to propose the Bayesian counterpart to compute CCC for continuous data. Material and Methods: A total of 33 patients of astrocytoma brain treated in the Department of Radiation Oncology at Malabar Cancer Centre is enrolled in this work. It is a continuous data of tumor volume and tumor size repeatedly measured during baseline pretreatment workup and post surgery follow-ups for all patients. The tumor volume and tumor size are measured separately by MRI and CT scan. The agreement of measurement between MRI and CT scan is calculated through CCC. The statistical inference is performed through Markov Chain Monte Carlo (MCMC technique. Results: Bayesian CCC is found suitable to get prominent evidence for test statistics to explore the relation between concordance measurements. The posterior mean estimates and 95% credible interval of CCC on tumor size and tumor volume are observed with 0.96(0.87,0.99 and 0.98(0.95,0.99 respectively. Conclusion: The Bayesian inference is adopted for development of the computational algorithm. The approach illustrated in this work provides the researchers an opportunity to find out the most appropriate model for specific data and apply CCC to fulfill the desired hypothesis.

  17. A Simple and Transparent Alternative to Repeated Measures ANOVA

    Directory of Open Access Journals (Sweden)

    James W. Grice

    2015-09-01

    Full Text Available Observation Oriented Modeling is a novel approach toward conceptualizing and analyzing data. Compared with traditional parametric statistics, Observation Oriented Modeling is more intuitive, relatively free of assumptions, and encourages researchers to stay close to their data. Rather than estimating abstract population parameters, the overarching goal of the analysis is to identify and explain distinct patterns within the observations. Selected data from a recent study by Craig et al. were analyzed using Observation Oriented Modeling; this analysis was contrasted with a traditional repeated measures ANOVA assessment. Various pitfalls in traditional parametric analyses were avoided when using Observation Oriented Modeling, including the presence of outliers and missing data. The differences between Observation Oriented Modeling and various parametric and nonparametric statistical methods were finally discussed.

  18. Matrix-based concordance correlation coefficient for repeated measures.

    Science.gov (United States)

    Hiriote, Sasiprapa; Chinchilli, Vernon M

    2011-09-01

    In many clinical studies, Lin's concordance correlation coefficient (CCC) is a common tool to assess the agreement of a continuous response measured by two raters or methods. However, the need for measures of agreement may arise for more complex situations, such as when the responses are measured on more than one occasion by each rater or method. In this work, we propose a new CCC in the presence of repeated measurements, called the matrix-based concordance correlation coefficient (MCCC) based on a matrix norm that possesses the properties needed to characterize the level of agreement between two p× 1 vectors of random variables. It can be shown that the MCCC reduces to Lin's CCC when p= 1. For inference, we propose an estimator for the MCCC based on U-statistics. Furthermore, we derive the asymptotic distribution of the estimator of the MCCC, which is proven to be normal. The simulation studies confirm that overall in terms of accuracy, precision, and coverage probability, the estimator of the MCCC works very well in general cases especially when n is greater than 40. Finally, we use real data from an Asthma Clinical Research Network (ACRN) study and the Penn State Young Women's Health Study for demonstration.

  19. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  20. A 12-month randomized crossover study on the effects of Lanreotide Autogel and Octreotide long-acting repeatable on GH and IGF-l in patients with acromegaly

    DEFF Research Database (Denmark)

    Andries, Magdalene; Glintborg, Dorte; Kvistborg, Annette

    2007-01-01

    of acromegaly in a randomized study design. Material and methods Twelve acromegalic patients were included and 10 patients completed treatment with LAN or OCT for 6 months and were then switched to the opposite treatment modality for 6 months without a washout period in a randomized crossover design. GH and IGF...

  1. Rank-Based Analysis of Unbalanced Repeated Measures Data

    Directory of Open Access Journals (Sweden)

    M. Mushfiqur Rashid

    2012-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} In this article, we have developed a rank (intra-subject based analysis of clinical trials with unbalanced repeated measures data. We assume that the errors within each patient are exchangeable and continuous random variables. This rank-based inference is valid when the unbalanced data are missing either completely at random or by design. A drop in dispersion test is developed for general linear hypotheses. A numerical example is given to illustrate the procedure.

  2. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study

    Directory of Open Access Journals (Sweden)

    Dancer Stephanie J

    2009-06-01

    Full Text Available Abstract Background Increasing hospital-acquired infections have generated much attention over the last decade. There is evidence that hygienic cleaning has a role in the control of hospital-acquired infections. This study aimed to evaluate the potential impact of one additional cleaner by using microbiological standards based on aerobic colony counts and the presence of Staphylococcus aureus including meticillin-resistant S. aureus. Methods We introduced an additional cleaner into two matched wards from Monday to Friday, with each ward receiving enhanced cleaning for six months in a cross-over design. Ten hand-touch sites on both wards were screened weekly using standardised methods and patients were monitored for meticillin-resistant S. aureus infection throughout the year-long study. Patient and environmental meticillin-resistant S. aureus isolates were characterised using molecular methods in order to investigate temporal and clonal relationships. Results Enhanced cleaning was associated with a 32.5% reduction in levels of microbial contamination at hand-touch sites when wards received enhanced cleaning (P S. aureus/S. aureus than sites further from the patient (P = 0.065. Genotyping identified indistinguishable strains from both hand-touch sites and patients. There was a 26.6% reduction in new meticillin-resistant S. aureus infections on the wards receiving extra cleaning, despite higher meticillin-resistant S. aureus patient-days and bed occupancy rates during enhanced cleaning periods (P = 0.032: 95% CI 7.7%, 92.3%. Adjusting for meticillin-resistant S. aureus patient-days and based upon nine new meticillin-resistant S. aureus infections seen during routine cleaning, we expected 13 new infections during enhanced cleaning periods rather than the four that actually occurred. Clusters of new meticillin-resistant S. aureus infections were identified 2 to 4 weeks after the cleaner left both wards. Enhanced cleaning saved the hospital £30

  3. Efficacy of wearing compression garments during post-exercise period after two repeated bouts of strenuous exercise: a randomized crossover design in healthy, active males.

    Science.gov (United States)

    Goto, Kazushige; Mizuno, Sahiro; Mori, Ayaka

    2017-12-01

    The efficacy of wearing [a] compression garment (CG) between repeated bouts of exercise within a same day has not been fully understood. The present study determined the effect of wearing a CG after strenuous exercise sessions (consisting of sprint exercise, resistance exercise, drop jump) twice a day on exercise performance, muscle damage, and inflammatory responses. Eleven physically active males (age, 22.7 ± 0.9 years; height, 175.7 ± 6.7 cm; body mass, 73.6 ± 10.2 kg; BMI, 23.8 ± 2.7 kg/m(2)) performed two trials (a randomized crossover design), consisting of the trial with either wearing a whole-body CG during post-exercise period (CG trial) or the trial with wearing a normal garment without specific pressure (CON trial). Two exercise sessions were conducted in the morning (09:00-10:00, Ex1) and afternoon (14:00-15:00, Ex2). Immediately after completing 60 min of each exercise, the subjects in the CG trial changed into a whole-body CG. Time-course changes in exercise performance (bench press power, jump performances, repeated sprint ability), blood variables (lactate, glucose, myoglobin, creatine kinase, interleukin-6, leptin), and scores of subjective feeling (fatigue, muscle soreness) were compared between the CG and CON trials before Ex1 (8:40), immediately before Ex2 (14:00, 4 h after Ex1), 4 h after Ex2 (19:00), and 24 h after the onset of Ex1 (9:00). Two bouts of exercise significantly decreased performances of counter movement jump (main effect for time: P = 0.04, F = 3.75, partial η (2) = 0.27) and rebound jump (main effect for time: P = 0.00, F = 12.22, partial η (2) = 0.55), while no significant difference was observed between the two trials (interaction: P = 0.10, F = 1.96, partial η (2) = 0.16 for counter movement jump, P = 0.93, F = 0.01, partial η (2) = 0.001 for rebound jump). Repeated sprint ability (power output during 10 × 6 s maximal sprint, 30-s rest

  4. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  5. The Effect of Nitrogen Cross-over on Proton Exchange Membrane Fuel Cell Water Balance Measurements Using Constant Temperature Anemometry

    DEFF Research Database (Denmark)

    Al Shakhshir, Saher; Berning, Torsten; Kær, Søren Knudsen

    2016-01-01

    A novel method to obtain an ad-hoc and real time electrical signal of the PEMFC water balance by employing a constant temperature hot wire anemometry has been developed by our fuel cell research group. In this work, the effect of nitrogen-cross over on this method is experimentally demonstrated....... This is due to the effect of 1% nitrogen on power law constant’s “m” which can be used in determining the water balance as explained in previous work was extremely low. Thus, the hot wire technique for measuring the PEMFC water balance is still accurate with the nitrogen cross-over...

  6. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  7. Detecting tropical forest biomass dynamics from repeated airborne lidar measurements

    Directory of Open Access Journals (Sweden)

    V. Meyer

    2013-08-01

    census data, differences of approximately one year between the ground census and lidar measurements, and differences in sensor characteristics. Our results indicate that the 50 ha BCI plot lost a significant amount of biomass (−0.8 Mg ha−1 yr−1 ± 2.2(SD over the past decade (2000–2010. Over the entire island and during the same period, mean AGB change was 0.2 ± 2.4 Mg ha−1 yr−1 with old growth forests losing −0.7 Mg ha−1 yr−1 ± 2.2 (SD, and secondary forests gaining +1.8 Mg ha yr−1 ± 3.4 (SD biomass. Our analysis suggests that repeated lidar surveys, despite taking measurement with different sensors, can estimate biomass changes in old-growth tropical forests at landscape scales (>10 ha.

  8. Using repeated measures of sleep disturbances to predict future diagnosis-specific work disability

    DEFF Research Database (Denmark)

    Salo, Paula; Vahtera, Jussi; Hall, Martica

    2012-01-01

    It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability.......It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability....

  9. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  10. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  11. Assessment of bone loss with repeated bone mineral measurements: Application to measurements on the individual patient

    Energy Technology Data Exchange (ETDEWEB)

    Wahner, H.W.

    1987-02-01

    Longitudinal measurements on lumbar spine and mid-radius were made by bone absorptiometry techniques in 139 normal women. Bone mineral was measured every 6 months over an median interval of 2.1 years. The results revealed that bone loss at different skeletal sites is non-uniform with equal bone loss patterns in all patients and relatively small variations in bone loss rate between normal women. For achieving these results there is strong demand on high precision and properly spaced measuring intervals for long-term rate of loss measurements. For exclusion of progressive degenerative disease a radiographic evaluation of the spine in the beginning and at the end of the study is mandatory as compression fractures or trauma reveal bone mineral changes independent from the agerelated bone loss. These repeated bone mineral measurements are useful for monitoring and follow-up studies during different therapeutic regimens.

  12. Endurance, aerobic high-intensity, and repeated sprint cycling performance is unaffected by normobaric "Live High-Train Low": a double-blind placebo-controlled cross-over study.

    Science.gov (United States)

    Bejder, Jacob; Andersen, Andreas Breenfeldt; Buchardt, Rie; Larsson, Tanja Hultengren; Olsen, Niels Vidiendal; Nordsborg, Nikolai Baastrup

    2017-05-01

    The aim was to investigate whether 6 weeks of normobaric "Live High-Train Low" (LHTL) using altitude tents affect highly trained athletes incremental peak power, 26-km time-trial cycling performance, 3-min all-out performance, and 30-s repeated sprint ability. In a double-blinded, placebo-controlled cross-over design, seven highly trained triathletes were exposed to 6 weeks of normobaric hypoxia (LHTL) and normoxia (placebo) for 8 h/day. LHTL exposure consisted of 2 weeks at 2500 m, 2 weeks at 3000 m, and 2 weeks at 3500 m. Power output during an incremental test, ~26-km time trial, 3-min all-out exercise, and 8 × 30 s of all-out sprint was evaluated before and after the intervention. Following at least 8 weeks of wash-out, the subjects crossed over and repeated the procedure. Incremental peak power output was similar after both interventions [LHTL: 375 ± 74 vs. 369 ± 70 W (pre-vs-post), placebo: 385 ± 60 vs. 364 ± 79 W (pre-vs-post)]. Likewise, mean power output was similar between treatments as well as before and after each intervention for time trial [LHTL: 257 ± 49 vs. 254 ± 54 W (pre-vs-post), placebo: 267 ± 57 vs. 267 ± 52 W (pre-vs-post)], and 3-min all-out [LHTL: 366 ± 68 vs. 369 ± 72 W (pre-vs-post), placebo: 365 ± 66 vs. 355 ± 71 W (pre-vs-post)]. Furthermore, peak- and mean power output during repeated sprint exercise was similar between groups at all time points (n = 5). In conclusion, 6 weeks of normobaric LHTL using altitude tents simulating altitudes of 2500-3500 m conducted in a double-blinded, placebo-controlled cross-over design do not affect power output during an incremental test, a ~26-km time-trial test, or 3-min all-out exercise in highly trained triathletes. Furthermore, 30 s of repeated sprint ability was unaltered.

  13. Precision measurement of the sound velocity in an ultracold fermi gas through the BEC-BCS crossover

    Science.gov (United States)

    Joseph, James Adlai

    A trapped Fermi gas near a collisional resonance provides a unique laboratory for testing many-body theories in a variety of fields. The ultracold Fermi gas produced in our lab is comprised of the lowest two spin states of 6Li. At 834 G there is a collisional or Feshbach resonance between the two spin states. The scattering length between trapped atoms of opposing spins far exceeds the interparticle spacing of the gas. On resonance, a strongly interacting, unitary, Fermi gas is created which exhibits universal behavior. The unitary Fermi gas is a prototype for other exotic systems in nature from nuclear matter to neutron stars and high temperature superconductors. For magnetic fields less than 834 G the scattering length is positive, and pairs Fermi atoms can form molecular dimers. These dimers, comprised of two fermions, are bosons. At ultracold temperatures the molecular bosons populate the lowest energy level and form a Bose Einstein Condensate (BEC). For magnetic fields greater than 834G the scattering length between fermions in opposing spin states is negative, like Cooper pairs formed between electrons in a superconductor. The Bardeen, Cooper, and Shriefer (BCS) theory was developed to describe the pairing effect in the context of superconductors. In our experiment we produce an ultracold unitary gas. By tuning the magnetic field to either side of the Feshbach resonance we can transform the gas into a weakly interacting BEC or BCS superfluid. Therefore, the region near a Feshbach resonance is called the BEC-BCS crossover. This dissertation presents a precision measurement of the hydrodynamic sound velocity in an ultracold Fermi gas near a Feshbach resonance. The sound velocity is measured at various magnetic fields both above and below resonance. Moreover, we are able compare our measurements to theoretical descriptions of hydrodynamic sound propagation. Further, our measurement of sound velocity exactly reproduces the non-perturbative case, eliminating the

  14. Influence of a user-adaptive prosthetic knee on quality of life, balance confidence, and measures of mobility: a randomised cross-over trial

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan; Nederhand, Marcus Johannes; Rietman, Johan Swanik; Koopman, Hubertus F.J.M.

    2015-01-01

    Objective: To study the influence of a transition from a non-microprocessor controlled to the Rheo Knee® II on quality of life, balance confidence and measures of mobility. Design: Randomised crossover trial. Setting: Research department of a rehabilitation centre. Subjects: Persons with a

  15. Influence of a user-adaptive prosthetic knee on quality of life, balance confidence, and measures of mobility: a randomised cross-over trial

    NARCIS (Netherlands)

    Prinsen, E.C.; Nederhand, M.J.; Rietman, J.S.; Koopman, H.F.J.M.

    2015-01-01

    Objective: To study the influence of a transition from a non-microprocessor controlled to the Rheo Knee® II on quality of life, balance confidence and measures of mobility. Design: Randomised crossover trial. Setting: Research department of a rehabilitation centre. Subjects: Persons with a tra

  16. Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.

    Science.gov (United States)

    Cruz, Antonio M; Maninchedda, Ugo E; Burger, Dominik; Wanda, Sabine; Vidondo, Beatriz

    2017-09-01

    OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.

  17. Analysis of repeated measurements from medical research when observations are missing

    OpenAIRE

    Walker, K.

    2007-01-01

    Subject dropout is a common problem in repeated measurements health stud ies. Where dropout is related to the response, the results obtained can be substantially biased. The research in this thesis is motivated by a repeated measurements asthma clinical trial with substantial patient dropout. In practice the extent to which missing observations affect parameter esti mates and their efficiency is not clear. Through extensive simulation studies under various scenarios and missing data mechanism...

  18. Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes

    Directory of Open Access Journals (Sweden)

    Carmen Lopez de la Fuente

    2014-01-01

    Full Text Available Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA in anterior segment examination. Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC, and coefficient of variation (COV. Results. Correlation among repeated measurements showed almost perfect reliability (ICC > 0.81 for all parameters except thinnest central corneal thickness (CCT (0.78, corneal thickness average out (0.79, and posterior axial curvature average out (0.60. Repeatability was excellent (COV < 10% for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean. Conclusions. GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.

  19. A Novel Signal Processing Measure to Identify Exact and Inexact Tandem Repeat Patterns in DNA Sequences

    Directory of Open Access Journals (Sweden)

    Ravi Gupta

    2007-03-01

    Full Text Available The identification and analysis of repetitive patterns are active areas of biological and computational research. Tandem repeats in telomeres play a role in cancer and hypervariable trinucleotide tandem repeats are linked to over a dozen major neurodegenerative genetic disorders. In this paper, we present an algorithm to identify the exact and inexact repeat patterns in DNA sequences based on orthogonal exactly periodic subspace decomposition technique. Using the new measure our algorithm resolves the problems like whether the repeat pattern is of period P or its multiple (i.e., 2P, 3P, etc., and several other problems that were present in previous signal-processing-based algorithms. We present an efficient algorithm of O(NLw logLw, where N is the length of DNA sequence and Lw is the window length, for identifying repeats. The algorithm operates in two stages. In the first stage, each nucleotide is analyzed separately for periodicity, and in the second stage, the periodic information of each nucleotide is combined together to identify the tandem repeats. Datasets having exact and inexact repeats were taken up for the experimental purpose. The experimental result shows the effectiveness of the approach.

  20. The concordance correlation coefficient for repeated measures estimated by variance components.

    Science.gov (United States)

    Carrasco, Josep L; King, Tonya S; Chinchilli, Vernon M

    2009-01-01

    The concordance correlation coefficient (CCC) is an index that is commonly used to assess the degree of agreement between observers on measuring a continuous characteristic. Here, a CCC for longitudinal repeated measurements is developed through the appropriate specification of the intraclass correlation coefficient from a variance components linear mixed model. A case example and the results of a simulation study are provided.

  1. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind li

  2. Hierarchical linear model: thinking outside the traditional repeated-measures analysis-of-variance box.

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C

    2015-04-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data.

  3. Hierarchical Linear Model: Thinking Outside the Traditional Repeated-Measures Analysis-of-Variance Box

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C.

    2015-01-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data. PMID:25875072

  4. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.

    Science.gov (United States)

    Wilson, Derek C; Niosi, Christina A; Zhu, Qingan A; Oxland, Thomas R; Wilson, David R

    2006-01-01

    We assessed the repeatability and accuracy of a relatively new, resistance-based sensor (Tekscan 6900) for measuring lumbar spine facet loads, pressures, and contact areas in cadaver specimens. Repeatability of measurements in the natural facet joint was determined for five trials of four specimens loaded in pure moment (+/- 7.5 N m) flexibility tests in axial rotation and flexion-extension. Accuracy of load measurements in four joints was assessed by applying known compressive loads of 25, 50, and 100 N to the natural facet joint in a materials testing machine and comparing the known applied load to the measured load. Measurements of load were obtained using two different calibration approaches: linear and two-point calibrations. Repeatability for force, pressure, and area (average of standard deviation as a percentage of the mean for all trials over all specimens) was 4-6% for axial rotation and 7-10% for extension. Peak resultant force in axial rotation was 30% smaller when calculated using the linear calibration method. The Tekscan sensor overestimated the applied force by 18 +/- 9% (mean+/-standard deviation), 35 +/- 7% and 50 +/- 9% for compressive loads of 100, 50, and 25 N, respectively. The two-point method overestimated the loads by 35 +/- 16%, 45 +/- 7%, and 56 +/- 10% for the same three loads. Our results show that the Tekscan sensor is repeatable. However, the sensor measurement range is not optimal for the small loads transmitted by the facets and measurement accuracy is highly dependent on calibration protocol.

  5. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  6. Repeated quantitative perfusion and contrast permeability measurement in the MRI examination of a CNS tumor

    Energy Technology Data Exchange (ETDEWEB)

    Vonken, E.P.A.; Osch, M.J.P. van; Willems, P.W.A.; Zwan, A. van der; Bakker, C.J.G.; Viergever, M.A.; Mali, W.P.T.M. [University Hospital Utrecht (Netherlands)

    2000-09-01

    This study reports on the results of quantitative MRI perfusion and contrast permeability measurement on two occasions in one patient. The measurements were separated 81 days in time. The tumor grew considerably in this period, but no change was found with respect to perfusion and contrast permeability. Non-involved white matter values were reproduced to demonstrate repeatability. The presented approach to dynamic susceptibility contrast MRI allows fast and repeatable quantitative assessment of perfusion and is easily integrated in a conventional brain tumor protocol. (orig.)

  7. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Directory of Open Access Journals (Sweden)

    Beatriz Antona

    2015-04-01

    Full Text Available AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus. METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision. RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability (COR: ±13 and ±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted. In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby (COR: ±69s arc and Randot (COR: ±72s arc. In both groups, the TNO test showed poorest agreement with the other tests. CONCLUSION: The repeatability of stereoacuity measures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  8. Effect of ischemic preconditioning in skeletal muscle measured by functional magnetic resonance imaging and spectroscopy: a randomized crossover trial

    Directory of Open Access Journals (Sweden)

    Bartko Johann

    2011-06-01

    Full Text Available Abstract Background Nuclear magnetic resonance (NMR imaging and spectroscopy have been applied to assess skeletal muscle oxidative metabolism. Therefore, in-vivo NMR may enable the characterization of ischemia-reperfusion injury. The goal of this study was to evaluate whether NMR could detect the effects of ischemic preconditioning (IPC in healthy subjects. Methods Twenty-three participants were included in two randomized crossover protocols in which the effects of IPC were measured by NMR and muscle force assessments. Leg ischemia was administered for 20 minutes with or without a subsequent impaired reperfusion for 5 minutes (stenosis model. IPC was administered 4 or 48 hours prior to ischemia. Changes in 31phosphate NMR spectroscopy and blood oxygen level-dependent (BOLD signals were recorded. 3-Tesla NMR data were compared to those obtained for isometric muscular strength. Results The phosphocreatine (PCr signal decreased robustly during ischemia and recovered rapidly during reperfusion. In contrast to PCr, the recovery of muscular strength was slow. During post-ischemic stenosis, PCr increased only slightly. The BOLD signal intensity decreased during ischemia, ischemic exercise and post-ischemic stenosis but increased during hyperemic reperfusion. IPC 4 hours prior to ischemia significantly increased the maximal PCr reperfusion signal and mitigated the peak BOLD signal during reperfusion. Conclusions Ischemic preconditioning positively influenced muscle metabolism during reperfusion; this resulted in an increase in PCr production and higher oxygen consumption, thereby mitigating the peak BOLD signal. In addition, an impairment of energy replenishment during the low-flow reperfusion was detected in this model. Thus, functional NMR is capable of characterizing changes in reperfusion and in therapeutic interventions in vivo. Trial Registration ClinicalTrials.gov: NCT00883467

  9. Repeatability of the modified Thorington card used to measure far heterophoria.

    Science.gov (United States)

    Cebrian, Jose Luis; Antona, Beatriz; Barrio, Ana; Gonzalez, Enrique; Gutierrez, Angel; Sanchez, Isabel

    2014-07-01

    To determine the interexaminer and intraexaminer repeatability of the modified Thorington test (TH) for distance vision in young adults and to compare these results with those observed for the heterophoria tests most commonly used in clinical practice. Agreement among tests was also assessed. Distance heterophoria was quantified on two separate occasions by two examiners in 110 subjects aged 18 to 32 years (mean, 19.74 years; SD, 2.5 years) using four different tests: cover test (CT) Von Graefe, Maddox rod, and modified TH. The repeatability of the tests and agreement between them was estimated by the Bland and Altman method whereby the mean difference and the 95% limits of agreement were determined as the coefficient of repeatability (COR) and coefficient of agreement. The Thorington test showed best interexaminer repeatability (COR = ±1.43Δ), followed closely by CT (COR = ±1.65Δ), whereas best intraexaminer repeatability was observed for CT (COR = ±1.28Δ) followed by TH (COR = ±1.51Δ). Among the different combinations of tests, TH and CT showed best agreement indicated by the lowest coefficient of agreement (±2.23Δ) and a low mean difference (-0.63Δ) between measurements. Good interexaminer and intraexaminer repeatability was observed for both TH and CT, and agreement between the two tests was also good. Given the simple administration of the TH, we recommend its clinical use to quantify distance horizontal heterophoria.

  10. Australian House Prices: A Comparison of Hedonic and Repeat-sales Measures

    OpenAIRE

    James Hansen

    2006-01-01

    House prices are intrinsically difficult to measure due to changes in the composition of properties sold through time and changes in the quality of housing. I provide an overview of the theoretical nature of these issues and consider how regression-based measures of house prices – hedonic and repeat-sales measures – can control for compositional and quality change. I then explore whether these regression-based alternatives can provide accurate estimates of pure house price changes in the Aust...

  11. Concordance correlation coefficients estimated by generalized estimating equations and variance components for longitudinal repeated measurements.

    Science.gov (United States)

    Tsai, Miao-Yu

    2017-04-15

    The concordance correlation coefficient (CCC) is a commonly accepted measure of agreement between two observers for continuous responses. This paper proposes a generalized estimating equations (GEE) approach allowing dependency between repeated measurements over time to assess intra-agreement for each observer and inter- and total agreement among multiple observers simultaneously. Furthermore, the indices of intra-, inter-, and total agreement through variance components (VC) from an extended three-way linear mixed model (LMM) are also developed with consideration of the correlation structure of longitudinal repeated measurements. Simulation studies are conducted to compare the performance of the GEE and VC approaches for repeated measurements from longitudinal data. An application of optometric conformity study is used for illustration. In conclusion, the GEE approach allowing flexibility in model assumptions and correlation structures of repeated measurements gives satisfactory results with small mean square errors and nominal 95% coverage rates for large data sets, and when the assumption of the relationship between variances and covariances for the extended three-way LMM holds, the VC approach performs outstandingly well for all sample sizes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Repeatability of cardiac-MRI-measured right ventricular size and function in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Rowan; Salem, Yishay [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Shah, Amee; Lai, Wyman W. [Morgan Stanley Children' s Hospital of New York Presbyterian, New York, NY (United States); Nielsen, James C. [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Mount Sinai Children' s Heart Center, Box 1201, New York, NY (United States)

    2011-08-15

    The measurement error for right ventricular (RV) size and function assessed by cardiac MRI (CMRI) in congenital heart disease has not been fully characterized. As CMRI parameters are being increasingly utilized to make clinical decisions, defining error in the clinical setting is critical. This investigation examines the repeatability of CMRI for RV size and function. Forty consecutive people with congenital heart disease involving the RV were retrospectively identified. Contouring of RV volumes was performed by two expert CMRI clinicians. The coefficient of variability and repeatability coefficients were calculated. Repeatability coefficients were multiplied by the mean value for each group studied to define a threshold beyond which measurement error was unlikely to be responsible. The variability for indexed RV end-diastolic volume = 3.2% and 3.3% for intra- and interobserver comparisons, respectively. The repeatability coefficients were 13.2% and 14.9% for intra- and interobserver comparisons, which yielded threshold values of 15.1 ml/m{sup 2} and 20.2 ml/m{sup 2}, respectively. For RV ejection fraction (EF), the repeatability coefficients for intra- and interobserver comparisons were 5.0% and 6.0%, which resulted in threshold values of 2.6 EF% and 3.0 EF%. The threshold values generated can be used during serial assessment of RV size and function. (orig.)

  13. Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues.

    Science.gov (United States)

    Liu, Helen; Holt, Cathy; Evans, Sam

    2007-01-01

    Optical motion analysis techniques have been widely used in biomechanics for measuring large-scale motions such as gait, but have not yet been significantly explored for measuring smaller movements such as the tooth displacements under load. In principle, very accurate measurements could be possible and this could provide a valuable tool in many engineering applications. The aim of this study was to evaluate accuracy and repeatability of the Qualisys ProReflex-MCU120 system when measuring small displacements, as a step towards measuring tooth displacements to characterise the properties of the periodontal ligament. Accuracy and repeatability of the system was evaluated using a wedge comparator with a resolution of 0.25 microm to provide measured marker displacements in three orthogonal directions. The marker was moved in ten steps in each direction, for each of seven step sizes (0.5, 1, 2, 3, 5, 10, and 20 microm), repeated five times. Spherical and diamond markers were tested. The system accuracy (i.e. percentage of maximum absolute error in range/measurement range), in the 20-200 microm ranges, was +/-1.17%, +/-1.67% and +/-1.31% for the diamond marker in x, y and z directions, while the system accuracy for the spherical marker was +/-1.81%, +/-2.37% and +/-1.39%. The system repeatability (i.e. maximum standard deviation in the measurement range) measured under the different days, light intensity and temperatures for five times, carried out step up and then step down measurements for the same step size, was +/-1.7, +/-2.3 and +/-1.9 microm for the diamond marker, and +/-2.6, +/-3.9 and +/-1.9 microm for the spherical marker in x, y and z directions, respectively. These results demonstrate that the system suffices accuracy for measuring tooth displacements and could potentially be useful in many other applications.

  14. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  15. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...

  16. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    2011-01-01

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and r

  17. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  18. REPEATABILITY OF THE SUGAR ABSORPTION TEST, USING LACTULOSE AND MANNITOL, FOR MEASURING INTESTINAL PERMEABILITY FOR SUGARS

    NARCIS (Netherlands)

    VANELBURG, RM; UIL, JJ; KOKKE, FTM; MULDER, AM; VANDEBROEK, WGM; MULDER, CJJ; HEYMANS, HSA

    1995-01-01

    Differential sugar-absorption tests for measuring intestinal permeability for sugars have been studied in a variety of gastrointestinal diseases. Their use in general practice has been hampered by a lack of data on reference values and repeatability of the test and the laboratory assay. In this stud

  19. The Multilevel Approach to Repeated Measures for Complete and Incomplete Data

    NARCIS (Netherlands)

    Maas, CJM; Snijders, TAB

    2003-01-01

    Repeated measurements often are analyzed by multivariate analysis of variance (MANOVA). An alternative approach is provided by multilevel analysis, also called the hierarchical linear model (HLM), which makes use of random coefficient models. This paper is a tutorial which indicates that the HLM can

  20. Optimal selection of individuals for repeated covariate measurements in follow-up studies.

    Science.gov (United States)

    Reinikainen, Jaakko; Karvanen, Juha; Tolonen, Hanna

    2016-12-01

    Repeated covariate measurements bring important information on the time-varying risk factors in long epidemiological follow-up studies. However, due to budget limitations, it may be possible to carry out the repeated measurements only for a subset of the cohort. We study cost-efficient alternatives for the simple random sampling in the selection of the individuals to be remeasured. The proposed selection criteria are based on forms of the D-optimality. The selection methods are compared with the simulation studies and illustrated with the data from the East-West study carried out in Finland from 1959 to 1999. The results indicate that cost savings can be achieved if the selection is focused on the individuals with high expected risk of the event and, on the other hand, on those with extreme covariate values in the previous measurements. © The Author(s) 2014.

  1. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Institute of Scientific and Technical Information of China (English)

    Beatriz; Antona; Ana; Barrio; Isabel; Sanchez; Enrique; Gonzalez; Guadalupe; Gonzalez

    2015-01-01

    AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24 h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability(COR): ±13 and±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted.In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby(COR: ±69s arc)and Randot(COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.CONCLUSION:Therepeatabilityofstereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  2. Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography

    Science.gov (United States)

    Chen, Chieh-Li; Bojikian, Karine D.; Xin, Chen; Wen, Joanne C.; Gupta, Divakar; Zhang, Qinqin; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.; Wang, Ruikang K.

    2016-06-01

    Optical coherence tomography angiography (OCTA) has increasingly become a clinically useful technique in ophthalmic imaging. We evaluate the repeatability and reproducibility of blood perfusion in the optic nerve head (ONH) measured using optical microangiography (OMAG)-based OCTA. Ten eyes from 10 healthy volunteers are recruited and scanned three times with a 68-kHz Cirrus HD-OCT 5000-based OMAG prototype system (Carl Zeiss Meditec Inc., Dublin, California) centered at the ONH involving two separate visits within six weeks. Vascular images are generated with OMAG processing by detecting the differences in OCT signals between consecutive B-scans acquired at the same retina location. ONH perfusion is quantified as flux, vessel area density, and normalized flux within the ONH for the prelaminar, lamina cribrosa, and the full ONH. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) are used to evaluate intravisit and intervisit repeatability, and interobserver reproducibility. ONH perfusion measurements show high repeatability [CV≤3.7% (intravisit) and ≤5.2% (intervisit)] and interobserver reproducibility (ICC≤0.966) in all three layers by three metrics. OCTA provides a noninvasive method to visualize and quantify ONH perfusion in human eyes with excellent repeatability and reproducibility, which may add additional insight into ONH perfusion in clinical practice.

  3. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    Directory of Open Access Journals (Sweden)

    Leroux Aurélia A

    2012-10-01

    Full Text Available Abstract Background Pulsed wave (PW Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research.

  4. Using the Monte Carlo Simulation Methods in Gauge Repeatability and Reproducibility of Measurement System Analysis

    Directory of Open Access Journals (Sweden)

    Tsu-Ming Yeh

    2013-10-01

    Full Text Available Measurements are required to maintain the consistent quality of all finished and semi-finished products in a production line. Many firms in the automobile and general precision industries apply the TS 16949:2009 Technical Specifications and Measurement System Analysis (MSA manual to establish measurement systems. This work is undertaken to evaluate gauge repeatability and reproducibility (GR&R to verify the measuring ability and quality of the measurement frame, as well as to continuously improve and maintain the verification process. Nevertheless, the implementation of GR&R requires considerable time and manpower, and is likely to affect production adversely. In addition, the evaluation value for GR&R is always different owing to the sum of man-made and machine-made variations. Using a Monte Carlo simulation and the prediction of the repeatability and reproducibility of the measurement system analysis, this study aims to determine the distribution of %GR&R and the related number of distinct categories (ndc. This study uses two case studies of an automobile parts manufacturer and the combination of a Monte Carlo simulation, statistical bases, and the prediction of the repeatability and reproducibility of the measurement system analysis to determine the probability density function, the distribution of %GR&R, and the related number of distinct categories (ndc. The method used in this study could evaluate effectively the possible range of the GR&R of the measurement capability, in order to establish a prediction model for the evaluation of the measurement capacity of a measurement system.

  5. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  6. Validity and repeatability of three in-shoe pressure measurement systems.

    Science.gov (United States)

    Price, Carina; Parker, Daniel; Nester, Christopher

    2016-05-01

    In-shoe pressure measurement devices are used in research and clinic to quantify plantar foot pressures. Various devices are available, differing in size, sensor number and type; therefore accuracy and repeatability. Three devices (Medilogic, Tekscan and Pedar) were examined in a 2 day×3 trial design, quantifying insole response to regional and whole insole loading. The whole insole protocol applied an even pressure (50-600kPa) to the insole surface for 0-30s in the Novel TruBlue™ device. The regional protocol utilised cylinders with contact surfaces of 3.14 and 15.9cm(2) to apply pressures of 50 and 200kPa. The validity (% difference and Root Mean Square Error: RMSE) and repeatability (Intra-Class Correlation Coefficient: ICC) of the applied pressures (whole insole) and contact area (regional) were outcome variables. Validity of the Pedar system was highest (RMSE 2.6kPa; difference 3.9%), with the Medilogic (RMSE 27.0kPa; difference 13.4%) and Tekscan (RMSE 27.0kPa; difference 5.9%) systems displaying reduced validity. The average and peak pressures demonstrated high between-day repeatability for all three systems and each insole size (ICC≥0.859). The regional contact area % difference ranged from -97 to +249%, but the ICC demonstrated medium to high between-day repeatability (ICC≥0.797). Due to the varying responses of the systems, the choice of an appropriate pressure measurement device must be based on the loading characteristics and the outcome variables sought. Medilogic and Tekscan were most effective between 200 and 300kPa; Pedar performed well across all pressures. Contact area was less precise, but relatively repeatable for all systems.

  7. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development...

  8. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  9. Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Hoffman, Jim; Miller, Tim; Lou, Yunling; Muellerschoen, Ron; Zebker, Howard; Madsen, Soren; Rosen, Paul

    2004-01-01

    Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

  10. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  11. Analysis of oligonucleotide array experiments with repeated measures using mixed models.

    Science.gov (United States)

    Li, Hao; Wood, Constance L; Getchell, Thomas V; Getchell, Marilyn L; Stromberg, Arnold J

    2004-12-30

    Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease) or absence (Control) of the disease, and brain regions including olfactory bulb (OB) or cerebellum (CER). In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH) procedure of controlling false discovery rate (FDR) at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the alpha-level (alphanew = 0.0033) determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD) procedure at the level of alphanew to control the family-wise error rate (FWER) for each gene examined. A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  12. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  13. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  14. On the repeated measures designs and sample sizes for randomized controlled trials.

    Science.gov (United States)

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials.

  15. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  16. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  17. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  18. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Science.gov (United States)

    Kroner, E.; Maboudian, R.; Arzt, E.

    2009-09-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  19. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Energy Technology Data Exchange (ETDEWEB)

    Kroner, E; Arzt, E [INM-Leibniz Institute for New Materials, Campus D2 2, 66125 Saarbruecken (Germany); Maboudian, R, E-mail: elmar.kroner@inm-gmbh.de [Department of Chem. Eng., 201 Gilman Hall, University of California, Berkeley, CA 94720-1462 (United States)

    2009-09-15

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  20. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  1. [Repeated measurement of memory with valenced test items: verbal memory, working memory and autobiographic memory].

    Science.gov (United States)

    Kuffel, A; Terfehr, K; Uhlmann, C; Schreiner, J; Löwe, B; Spitzer, C; Wingenfeld, K

    2013-07-01

    A large number of questions in clinical and/or experimental neuropsychology require the multiple repetition of memory tests at relatively short intervals. Studies on the impact of the associated exercise and interference effects on the validity of the test results are rare. Moreover, hardly any neuropsychological instruments exist to date to record the memory performance with several parallel versions in which the emotional valence of the test material is also taken into consideration. The aim of the present study was to test whether a working memory test (WST, a digit-span task with neutral or negative distraction stimuli) devised by our workgroup can be used with repeated measurements. This question was also examined in parallel versions of a wordlist learning paradigm and an autobiographical memory test (AMT). Both tests contained stimuli with neutral, positive and negative valence. Twenty-four participants completed the memory testing including the working memory test and three versions of a wordlist and the AMT at intervals of a week apiece (measuring points 1. - 3.). The results reveal consistent performances across the three measuring points in the working and autobiographical memory test. The valence of the stimulus material did not influence the memory performance. In the delayed recall of the wordlist an improvement in memory performance over time was seen. The tests on working memory presented and the parallel versions for the declarative and autobiographical memory constitute informal economic instruments within the scope of the measurement repeatability designs. While the WST and AMT are appropriate for study designs with repeated measurements at relatively short intervals, longer intervals might seem more favourable for the use of wordlist learning paradigms. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Validity and repeatability of a depth camera-based surface imaging system for thigh volume measurement.

    Science.gov (United States)

    Bullas, Alice M; Choppin, Simon; Heller, Ben; Wheat, Jon

    2016-10-01

    Complex anthropometrics such as area and volume, can identify changes in body size and shape that are not detectable with traditional anthropometrics of lengths, breadths, skinfolds and girths. However, taking these complex with manual techniques (tape measurement and water displacement) is often unsuitable. Three-dimensional (3D) surface imaging systems are quick and accurate alternatives to manual techniques but their use is restricted by cost, complexity and limited access. We have developed a novel low-cost, accessible and portable 3D surface imaging system based on consumer depth cameras. The aim of this study was to determine the validity and repeatability of the system in the measurement of thigh volume. The thigh volumes of 36 participants were measured with the depth camera system and a high precision commercially available 3D surface imaging system (3dMD). The depth camera system used within this study is highly repeatable (technical error of measurement (TEM) of <1.0% intra-calibration and ~2.0% inter-calibration) but systematically overestimates (~6%) thigh volume when compared to the 3dMD system. This suggests poor agreement yet a close relationship, which once corrected can yield a usable thigh volume measurement.

  3. Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies.

    Science.gov (United States)

    Schall, Mark C; Fethke, Nathan B; Chen, Howard; Oyama, Sakiko; Douphrate, David I

    2016-04-01

    The accuracy and repeatability of an inertial measurement unit (IMU) system for directly measuring trunk angular displacement and upper arm elevation were evaluated over eight hours (i) in comparison to a gold standard, optical motion capture (OMC) system in a laboratory setting, and (ii) during a field-based assessment of dairy parlour work. Sample-to-sample root mean square differences between the IMU and OMC system ranged from 4.1° to 6.6° for the trunk and 7.2°-12.1° for the upper arm depending on the processing method. Estimates of mean angular displacement and angular displacement variation (difference between the 90th and 10th percentiles of angular displacement) were observed to change IMU system may serve as an acceptable instrument for directly measuring trunk and upper arm postures in field-based occupational exposure assessment studies with long sampling durations. Practitioner Summary: Few studies have evaluated inertial measurement unit (IMU) systems in the field or over long sampling durations. Results of this study indicate that the IMU system evaluated has reasonably good accuracy and repeatability for use in a field setting over a long sampling duration.

  4. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Hensley, Scott; Lou, Yunling; Rosen, Paul; Wheeler, Kevin; Zebker, Howard; Madsen, Soren; Miller, Tim; Hoffman, Jim; Farra, Don

    2003-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeat-pass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV) or minimally piloted vehicle (MPV). Upon surveying the capabilities and availabilities of such aircraft, the Proteus aircraft and the ALTAIR UAV appear to meet our criteria in terms of payload capabilities, flying altitude, and endurance. To support the repeat pass deformation capability it is necessary to control flight track capability of the aircraft to be within a specified 10 m tube with a goal of 1 m. This requires real-time GPS control of the autopilot to achieve these objectives that has not been demonstrated on these aircraft. Based on the Proteus and ALTAIR's altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and a 16 km range swath. The radar will have an active electronic beam steering antenna to achieve a Doppler centroid stability that is necessary for repeat-pass interferometry. This paper presents some of the trade studies for the platform, instrument and the expected science.

  5. Measurement of bedform migration rates on the Lower Missouri River in Missouri, USA using repeat measurements with a multibeam echosounder

    Science.gov (United States)

    Elliott, Caroline M.; Jacobson, Robert B.

    2016-01-01

    High-resolution repeat multibeam echosounder measurements on the Lower Missouri River near Boonville, Missouri, USA show bedform movement and sand storage patterns over daily to seasonal time scales and a range of discharges. Higher flows are frequently, but not always, associated with larger bedforms, higher bedform movement rates, and higher bedload transport rates. Measurements of the temporal and spatial variability in sand dune sizes, transport rates, and sand storage across the river channel have increased understanding of the dynamics of habitats utilized by benthic organisms over multiple life stages and daily to seasonal time scales.

  6. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability

    Directory of Open Access Journals (Sweden)

    Sousa Filipe

    2015-12-01

    Full Text Available Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p < 0.05. Pearson product-moment correlation measured the relationship between mechanical variables and free running performance. A total impulse, the rate of force development and maximum force did not show significant differences for most sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35. Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p < 0.001, followed by mean force (r = -0.61; p < 0.001 and total work (r = -0.50; p < 0.001. It was concluded that under a severe work-to-rest ratio condition, power variables were better suited to evaluating repeated sprint ability than the other studied variables.

  7. Characterisation and measurement of signals generated by DVB-H 'GAP-filler' repeaters.

    Science.gov (United States)

    Baldini, M; Barellini, A; Bogi, L; Licitra, G; Silvi, A M; Zari, A

    2009-12-01

    DVB-H (Digital Video Broadcasting Handheld) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains.

  8. Measuring the Activity of Leucine-Rich Repeat Kinase 2: A Kinase Involved in Parkinson's Disease

    Science.gov (United States)

    Lee, Byoung Dae; Li, Xiaojie; Dawson, Ted M.; Dawson, Valina L.

    2015-01-01

    Mutations in the LRRK2 (Leucine-Rich Repeat Kinase 2) gene are the most common cause of autosomal dominant Parkinson's disease. LRRK2 has multiple functional domains including a kinase domain. The kinase activity of LRRK2 is implicated in the pathogenesis of Parkinson's disease. Developing an assay to understand the mechanisms of LRRK2 kinase activity is important for the development of pharmacologic and therapeutic applications. Here, we describe how to measure in vitro LRRK2 kinase activity and its inhibition. PMID:21960214

  9. Iterative Weighted Semiparametric Least Squares Estimation in Repeated Measurement Partially Linear Regression Models

    Institute of Scientific and Technical Information of China (English)

    Ge-mai Chen; Jin-hong You

    2005-01-01

    Consider a repeated measurement partially linear regression model with an unknown vector pasemiparametric generalized least squares estimator (SGLSE) ofβ, we propose an iterative weighted semiparametric least squares estimator (IWSLSE) and show that it improves upon the SGLSE in terms of asymptotic covariance matrix. An adaptive procedure is given to determine the number of iterations. We also show that when the number of replicates is less than or equal to two, the IWSLSE can not improve upon the SGLSE.These results are generalizations of those in [2] to the case of semiparametric regressions.

  10. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  11. Repeatability and Accuracy of Exoplanet Eclipse Depths Measured with Post-Cryogenic Spitzer

    CERN Document Server

    Ingalls, James G; Carey, S J; Stauffer, John R; Lawrence, Patrick J; Grillmair, Carl J; Buzasi, Derek; Deming, Drake; Diamond-Lowe, Hannah; Evans, Thomas M; Morello, G; Stevenson, Kevin B; Wong, Ian; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa

    2016-01-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5{\\mu}m dataset, consisting of 10 observations of the XO-3 b system during secondary eclipse, using 7 different techniques for removing correlated noise. We find that, on average, for a given technique the eclipse depth estimate is repeatable from epoch to epoch to within 150 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 2 of the photon noise limit. Nearly all methods accurately assess their own errors: for these methods the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10-epoch sample. To assess the accuracy of the techniques as well as clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated datas...

  12. Repeatability and reproducibility of horizontal corneal diameter and anterior corneal power measurements using the Oculus Keratograph 4

    Directory of Open Access Journals (Sweden)

    Khathutshelo P. Mashige

    2016-03-01

    Full Text Available Purpose: To evaluate the repeatability and reproducibility of horizontal corneal diameter (HCD and anterior corneal power (ACP measurements obtained with the Oculus Keratograph 4 (OCULUS Optikgeräte GmbH.Methods: These parameters (HCD and ACP were prospectively measured in quick succession three times in each of the right eyes of 40 healthy subjects, aged 18–28 years, with normal vision (6/6 or better visual acuity in the first session by a single examiner. Measurements were then repeated in the second session scheduled 1 week later by the same examiner using the same instrument. Repeatability and reproducibility of HCD and ACP measurements was assessed based on the intra-session and intersession within-subject standard deviation (sw, repeatability (2.77sw, coefficient of variation (CoV and intra-class correlation coefficient (ICC.Results: Intra-session repeatability and intersession reproducibility of all measured parameters showed a repeatability (2.77sw of 0.35 mm or less for HCD and 0.35 D or less for ACP, a CoV of 0.30% or less and an ICC of more than 0.9.Conclusion: HCD and ACP measurements obtained using an Oculus Keratograph 4 show good repeatability and reproducibility in healthy eyes; therefore, these parameters can be used for longitudinal follow-up when measured with this device.

  13. Measuring the Dynamic Soil Response During Repeated Wheeling Using Seismic Methods

    DEFF Research Database (Denmark)

    Keller, Thomas; Carizzon, Marco; Berisso, Feto Esimo

    2013-01-01

    Our understanding of soil deformation processes, especially its dynamics, remains limited. This hampers accurate predictions of the impact of soil management practices such as agricultural field traffic on (physical) soil functions. The main objective of this study was to investigate whether...... seismic measurements could be used to assess the dynamic soil behavior during repeated loading. Moreover, we aimed at linking the velocity of P-waves, Vp, to traditionally measured soil properties associated with soil compaction, namely bulk density (ρb) and penetrometer resistance. A wheeling experiment......, and simulated the evolution of bulk density due to the wheeling using a soil compaction model. The dynamic soil response during loading–unloading–reloading cycles could be well captured with the seismic method. The measured Vp related to bulk density, and the compaction-induced increase in Vp correlated...

  14. Information Contents of a Signal at Repeated Positioning Measurements of the Coordinate Measuring Machine (CMM by Laser Interferometer

    Directory of Open Access Journals (Sweden)

    Stejskal Tomáš

    2016-10-01

    Full Text Available The input of this paper lies in displaying possibilities how to determine the condition of a coordinate measuring machine (CMM based on a large number of repeated measurements. The number of repeated measurements exceeds common requirements for determining positioning accuracy. The total offset in the accuracy of spatial positioning consists of partial inaccuracies of individual axes. 6 basic errors may be defined at each axis. In a triaxial set, that translates into 18 errors, to which an offset from the perpendicularity between the axial pairs must be added. Therefore, the combined number of errors in a single position is 21. These errors are systemic and stem from the machine’s geometry. In addition, there are accidental errors to account for as well. Accidental errors can be attributed to vibrations, mass inertness, passive resistance, and in part to fluctuations in temperature. A peculiar set of systemic errors are time-varying errors. The nature of those errors may be reversible, for instance if they result from influence of temperature or elastic deformation. They can be also irreversible, for example as a result of wear and tear or line clogging, due to loosened connection or permanent deformation of a part post collision. A demonstration of thermal equalizing of the machine’s parts may also be observed in case of failure to adhere to a sufficient time interval from the moment the air-conditioning is turned on. Repeated measurements done on a selected axis with linear interferometer can provide complex information on the CMM condition and also on the machine’s interaction with the given technical environment.

  15. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability.

    Science.gov (United States)

    Sousa, Filipe; Dos Reis, Ivan; Ribeiro, Luiz; Martins, Luiz; Gobatto, Claudio

    2015-12-22

    Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s) completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35). Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p sprint ability than the other studied variables.

  16. On the Analysis of a Repeated Measure Design in Genome-Wide Association Analysis

    Directory of Open Access Journals (Sweden)

    Young Lee

    2014-11-01

    Full Text Available Longitudinal data enables detecting the effect of aging/time, and as a repeated measures design is statistically more efficient compared to cross-sectional data if the correlations between repeated measurements are not large. In particular, when genotyping cost is more expensive than phenotyping cost, the collection of longitudinal data can be an efficient strategy for genetic association analysis. However, in spite of these advantages, genome-wide association studies (GWAS with longitudinal data have rarely been analyzed taking this into account. In this report, we calculate the required sample size to achieve 80% power at the genome-wide significance level for both longitudinal and cross-sectional data, and compare their statistical efficiency. Furthermore, we analyzed the GWAS of eight phenotypes with three observations on each individual in the Korean Association Resource (KARE. A linear mixed model allowing for the correlations between observations for each individual was applied to analyze the longitudinal data, and linear regression was used to analyze the first observation on each individual as cross-sectional data. We found 12 novel genome-wide significant disease susceptibility loci that were then confirmed in the Health Examination cohort, as well as some significant interactions between age/sex and SNPs.

  17. Multiple-objective response-adaptive repeated measurement designs in clinical trials for binary responses.

    Science.gov (United States)

    Liang, Yuanyuan; Li, Yin; Wang, Jing; Carriere, Keumhee C

    2014-02-20

    A multiple-objective allocation strategy was recently proposed for constructing response-adaptive repeated measurement designs for continuous responses. We extend the allocation strategy to constructing response-adaptive repeated measurement designs for binary responses. The approach with binary responses is quite different from the continuous case, as the information matrix is a function of responses, and it involves nonlinear modeling. To deal with these problems, we first build the design on the basis of success probabilities. Then we illustrate how various models can accommodate carryover effects on the basis of logits of response profiles as well as any correlation structure. Through computer simulations, we find that the allocation strategy developed for continuous responses also works well for binary responses. As expected, design efficiency in terms of mean squared error drops sharply, as more emphasis is placed on increasing treatment benefit than estimation precision. However, we find that it can successfully allocate more patients to better treatment sequences without sacrificing much estimation precision.

  18. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg

    Science.gov (United States)

    van Zantvoort, Aniek P. M.; de Bruijn, Johan A.; Winkes, Michiel B.; Hoogeveen, Adwin R.; Teijink, Joep A. W.; Scheltinga, Marc R.

    2017-01-01

    Background: The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. Purpose: To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Study Design: Case series; Level of evidence, 4. Methods: Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. Results: A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ2 = 1.928, P = .381). Sex (χ2 = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ2 = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15

  19. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg.

    Science.gov (United States)

    van Zantvoort, Aniek P M; de Bruijn, Johan A; Winkes, Michiel B; Hoogeveen, Adwin R; Teijink, Joep A W; Scheltinga, Marc R

    2017-06-01

    The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Case series; Level of evidence, 4. Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ(2) = 1.928, P = .381). Sex (χ(2) = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ(2) = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15 patients [53% female]; mean age, 31 ± 10 years

  20. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  1. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  2. Impact of repeated measures and sample selection on genome-wide association studies of fasting glucose

    Science.gov (United States)

    Rasmussen-Torvik, Laura J.; Alonso, Alvaro; Li, Man; Kao, Wen; Köttgen, Anna; Yan, Yuer; Couper, David; Boerwinkle, Eric; Bielinski, Suzette J.; Pankow, James S.

    2010-01-01

    Although GWAS have been performed in longitudinal studies, most used only a single trait measure. GWAS of fasting glucose have generally included only normoglycemic individuals. We examined the impact of both repeated measures and sample selection on GWAS in ARIC, a study which obtained four longitudinal measures of fasting glucose and included both individuals with and without prevalent diabetes. The sample included Caucasians and the Affymetrix 6.0 chip was used for genotyping. Sample sizes for GWAS analyses ranged from 8372 (first study visit) to 5782 (average fasting glucose). Candidate SNP analyses with SNPs identified through fasting glucose or diabetes GWAS were conducted in 9133 individuals, including 761 with prevalent diabetes. For a constant sample size, smaller p-values were obtained for the average measure of fasting glucose compared to values at any single visit, and two additional significant GWAS signals were detected. For four candidate SNPs (rs780094, rs10830963, rs7903146, and rs4607517), the strength of association between genotype and glucose was significantly (p-interaction fasting glucose candidate SNPs (rs780094, rs10830963, rs560887, rs4607517, rs13266634) the association with measured fasting glucose was more significant in the smaller sample without prevalent diabetes than in the larger combined sample of those with and without diabetes. This analysis demonstrates the potential utility of averaging trait values in GWAS studies and explores the advantage of using only individuals without prevalent diabetes in GWAS of fasting glucose. PMID:20839289

  3. Estimation of the concordance correlation coefficient for repeated measures using SAS and R.

    Science.gov (United States)

    Carrasco, Josep L; Phillips, Brenda R; Puig-Martinez, Josep; King, Tonya S; Chinchilli, Vernon M

    2013-03-01

    The concordance correlation coefficient is one of the most common approaches used to assess agreement among different observers or instruments when the outcome of interest is a continuous variable. A SAS macro and R package are provided here to estimate the concordance correlation coefficient (CCC) where the design of the data involves repeated measurements by subject and observer. The CCC is estimated using U-statistics (UST) and variance components (VC) approaches. Confidence intervals and standard errors are reported along with the point estimate of the CCC. In the case of the VC approach, the linear mixed model output and variance components estimates are also provided. The performance of each function is shown by means of some examples with real data sets.

  4. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...... patterns estimated in RM-APIM. Interpretation of results from these models largely focuses on the meaning of single-parameter estimates in isolation from all the others. However, considering individual coefficients separately impedes the understanding of how these associations combine to produce...... to improve the understanding and presentation of dyadic patterns of association described by standard RM-APIMs. The current article briefly reviews the conceptual foundations of RM-APIMs, demonstrates how change-as-outcome RM-APIMs and VFDs can aid interpretation of standard RM-APIMs, and provides a tutorial...

  5. Inmate responses to prison-based drug treatment: a repeated measures analysis.

    Science.gov (United States)

    Welsh, Wayne N

    2010-06-01

    Using a sample of 347 prison inmates and general linear modeling (GLM) repeated measures analyses, this paper examined during-treatment responses (e.g., changes in psychological and social functioning) to prison-based TC drug treatment. These effects have rarely been examined in previous studies, and never with a fully multivariate model accounting for within-subjects effects (changes over time), between-subjects effects (e.g., levels of risk and motivation), and within/between-subjects interactions (timexriskxmotivation). The results provide evidence of positive inmate change in response to prison TC treatment, but the patterns of results varied depending upon: (a) specific indicators of psychological and social functioning, motivation, and treatment process; (b) the time periods examined (1, 6, and 12 months during treatment); and (c) baseline levels of risk and motivation. Significant interactions between time and type of inmate suggest important new directions for research, theory, and practice in offender-based substance abuse treatment.

  6. Bayesian latent variable models for hierarchical clustered count outcomes with repeated measures in microbiome studies.

    Science.gov (United States)

    Xu, Lizhen; Paterson, Andrew D; Xu, Wei

    2017-04-01

    Motivated by the multivariate nature of microbiome data with hierarchical taxonomic clusters, counts that are often skewed and zero inflated, and repeated measures, we propose a Bayesian latent variable methodology to jointly model multiple operational taxonomic units within a single taxonomic cluster. This novel method can incorporate both negative binomial and zero-inflated negative binomial responses, and can account for serial and familial correlations. We develop a Markov chain Monte Carlo algorithm that is built on a data augmentation scheme using Pólya-Gamma random variables. Hierarchical centering and parameter expansion techniques are also used to improve the convergence of the Markov chain. We evaluate the performance of our proposed method through extensive simulations. We also apply our method to a human microbiome study.

  7. Causal inference in longitudinal comparative effectiveness studies with repeated measures of a continuous intermediate variable.

    Science.gov (United States)

    Wang, Chen-Pin; Jo, Booil; Brown, C Hendricks

    2014-09-10

    We propose a principal stratification approach to assess causal effects in nonrandomized longitudinal comparative effectiveness studies with a binary endpoint outcome and repeated measures of a continuous intermediate variable. Our method is an extension of the principal stratification approach originally proposed for the longitudinal randomized study "Prevention of Suicide in Primary Care Elderly: Collaborative Trial" to assess the treatment effect on the continuous Hamilton depression score adjusting for the heterogeneity of repeatedly measured binary compliance status. Our motivation for this work comes from a comparison of the effect of two glucose-lowering medications on a clinical cohort of patients with type 2 diabetes. Here, we consider a causal inference problem assessing how well the two medications work relative to one another on two binary endpoint outcomes: cardiovascular disease-related hospitalization and all-cause mortality. Clinically, these glucose-lowering medications can have differential effects on the intermediate outcome, glucose level over time. Ultimately, we want to compare medication effects on the endpoint outcomes among individuals in the same glucose trajectory stratum while accounting for the heterogeneity in baseline covariates (i.e., to obtain 'principal effects' on the endpoint outcomes). The proposed method involves a three-step model estimation procedure. Step 1 identifies principal strata associated with the intermediate variable using hybrid growth mixture modeling analyses. Step 2 obtains the stratum membership using the pseudoclass technique and derives propensity scores for treatment assignment. Step 3 obtains the stratum-specific treatment effect on the endpoint outcome weighted by inverse propensity probabilities derived from Step 2.

  8. The Ubiquity Of Crossover

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    If the word 'crossover' is unfamiliar to you, perhaps it is time to get to grips with this modern phenomenon. It is one of those vague words that one is never quite clear about; how did it start? What exactly does it mean? Crossover seems to have infiltrated our lives without us even noticing.

  9. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  10. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate....... Our study suggests that the blood transcriptome of healthy individuals is reproducible over a time period of several months. © 2013 Elsevier Inc....

  11. Status of a UAVSAR designed for repeat pass interferometry for deformation measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Sadowy, Greg; Miller, Tim; Shaffer, Scott; Muellerschoen, Ron; Jones, Cathleen; Zebker, Howard; Madsen, Soren; Paul, Rose

    2005-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also known as differential interferometric measurements. Differential interferometry can provide key deformation measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The expected performance of the flight control system will constrain the flight path to be within a 10 m diameter tube about the desired flight track. The radar wilI be designed to operate on a UAV (Unpiloted Aria1 Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus buitt by Scaled Composites or on a NASA Gulfstream III. The radar design is a fully polarimetric with an 80 MHz bandwidth (2 m range resolution) and 16 km range swath. The antenna is an electronically steered along track to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. Other features supported by the antenna include an elevation monopulse option and a pulse-to-pulse resteering capability that will enable some novel modes of operation. The system will nominally operate at 45,000 ft (13800 m). The program began out as an Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  12. Repeated measures of serum glucose and insulin in relation to postmenopausal breast cancer.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi; Caan, Bette J; Chlebowski, Rowan T; Gunter, Marc J; Ho, Gloria Y F; Rodriguez, Beatriz L; Shikany, James M; Strickler, Howard D; Vitolins, Mara Z; Rohan, Thomas E

    2009-12-01

    Experimental and epidemiological evidence suggests that circulating glucose and insulin may play a role in breast carcinogenesis. However, few cohort studies have examined breast cancer risk in association with glucose and insulin levels, and studies to date have had only baseline measurements of exposure. We conducted a longitudinal study of postmenopausal breast cancer risk using the 6% random sample of women in the Women's Health Initiative clinical trials whose fasting blood samples, provided at baseline and at years 1, 3 and 6, were analyzed for glucose and insulin. In addition, a 1% sample of women in the observational study, who had glucose and insulin measured in fasting blood samples drawn at baseline and in year 3, were included in the analysis. We used Cox proportional hazards models to estimate hazard ratios and 95% confidence intervals for the association of baseline and follow-up measurements of serum glucose and insulin with breast cancer risk. All statistical tests were 2-sided. Among 5,450 women with baseline serum glucose and insulin values, 190 incident cases of breast cancer were ascertained over a median of 8.0 years of follow-up. The highest tertile of baseline insulin, relative to the lowest, was associated with a 2-fold increase in risk in the total population (multivariable hazard ratio 2.22, 95% confidence interval 1.39-3.53) and with a 3-fold increase in risk in women who were not enrolled in the intervention arm of any clinical trial (multivariable hazard ratio 3.15, 95% confidence interval 1.61-6.17). Glucose levels showed no association with risk. Analysis of the repeated measurements supported the results of the baseline analysis. These data suggest that elevated serum insulin levels may be a risk factor for postmenopausal breast cancer.

  13. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Ppressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  14. Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2017-01-01

    Full Text Available Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France. Three consecutive measurements were obtained. The within-subject standard deviation (Sw, intrasubject precision (1.96×Sw, and intraclass correlation coefficient (ICC were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689. Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.

  15. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  16. Constructing Measure by Repeated Infinite Subdivision%通过反复无限细分定义测度

    Institute of Scientific and Technical Information of China (English)

    严质彬

    2005-01-01

    This paper generalizes the method of constructing measure by repeated finite subdivision in fTactal geometry to that by infinite subdivision. Two conditions for the existing method are removed. A measure on the interval [0, 1] is constructed using this generalized method.

  17. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure, choles

  18. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure,

  19. Tracking photon jumps with repeated quantum non-demolition parity measurements.

    Science.gov (United States)

    Sun, L; Petrenko, A; Leghtas, Z; Vlastakis, B; Kirchmair, G; Sliwa, K M; Narla, A; Hatridge, M; Shankar, S; Blumoff, J; Frunzio, L; Mirrahimi, M; Devoret, M H; Schoelkopf, R J

    2014-07-24

    Quantum error correction is required for a practical quantum computer because of the fragile nature of quantum information. In quantum error correction, information is redundantly stored in a large quantum state space and one or more observables must be monitored to reveal the occurrence of an error, without disturbing the information encoded in an unknown quantum state. Such observables, typically multi-quantum-bit parities, must correspond to a special symmetry property inherent in the encoding scheme. Measurements of these observables, or error syndromes, must also be performed in a quantum non-demolition way (projecting without further perturbing the state) and more quickly than errors occur. Previously, quantum non-demolition measurements of quantum jumps between states of well-defined energy have been performed in systems such as trapped ions, electrons, cavity quantum electrodynamics, nitrogen-vacancy centres and superconducting quantum bits. So far, however, no fast and repeated monitoring of an error syndrome has been achieved. Here we track the quantum jumps of a possible error syndrome, namely the photon number parity of a microwave cavity, by mapping this property onto an ancilla quantum bit, whose only role is to facilitate quantum state manipulation and measurement. This quantity is just the error syndrome required in a recently proposed scheme for a hardware-efficient protected quantum memory using Schrödinger cat states (quantum superpositions of different coherent states of light) in a harmonic oscillator. We demonstrate the projective nature of this measurement onto a region of state space with well-defined parity by observing the collapse of a coherent state onto even or odd cat states. The measurement is fast compared with the cavity lifetime, has a high single-shot fidelity and has a 99.8 per cent probability per single measurement of leaving the parity unchanged. In combination with the deterministic encoding of quantum information in cat

  20. Assessing variability and comparing short-term biomarkers of styrene exposure using a repeated measurements approach.

    Science.gov (United States)

    Fustinoni, S; Manini, P; Campo, L; De Palma, G; Andreoli, R; Mutti, A; Bertazzi, P A; Rappaport, S M

    2010-01-15

    The aim of this work is to compare several short-term biomarkers of styrene exposure, namely urinary styrene (StyU), mercapturic acids (M1+M2), mandelic acid (MA), phenylglyoxylic acid (PGA), phenylglycine (PHG), and 4-vinylphenol conjugates (VP), for use as biomarkers of exposure in epidemiologic studies. A repeated measurements protocol (typically 4 measurements per worker over 6 weeks) was applied to measure airborne styrene (StyA) and urinary biomarkers in 10 varnish and 8 fiberglass reinforced plastic workers. Estimated geometric mean personal exposures to StyA were 2.96mg/m(3) in varnish workers and 15.7mg/m(3) in plastic workers. The corresponding levels of StyU, M1+M2, MA, PGA, MA+PGA, PHG and VP were 5.13microg/L, 0.111, 38.2, 22.7, 62.6, 0.978, and 3.97mg/g creatinine in varnish workers and 8.38microg/L, 0.303, 146, 83.4, 232, 2.85 and 3.97mg/g creatinine in plastic workers. Within-worker (sigma(wY)(2)) and between-worker (sigma(bY)(2)) variance components were estimated from the log-transformed data as were the corresponding fold ranges containing 95% of the respective lognormal distributions of daily levels ((w)R(0.95)) and subject-specific mean levels ((b)R(0.95)). Estimates of (w)R(0.95) (range: 4-26) were generally smaller than those of (b)R(0.95) (range: 5-790) for both environmental and biological markers; this indicates that exposures varied much more between workers than within workers in these groups. Since attenuation bias in an estimated exposure-response relationship increases with the variance ratio lambda=sigma(wY)(2)/sigma(bY)(2), we estimated values of lambda for all exposure measures in our study. Values of lambda were typically much less than one (median=0.220) and ranged from 0.089 for M1+M2 in plastic workers to 1.38 for PHG in varnish workers. Since values of lambda were 0.147 and 0.271 for StyA in varnish workers and plastic workers, respectively, compared to 0.178 and 0.210 for MA in the same groups, our results suggest that either

  1. Analyzing repeated measures semi-continuous data, with application to an alcohol dependence study.

    Science.gov (United States)

    Liu, Lei; Strawderman, Robert L; Johnson, Bankole A; O'Quigley, John M

    2016-02-01

    Two-part random effects models (Olsen and Schafer,(1) Tooze et al.(2)) have been applied to repeated measures of semi-continuous data, characterized by a mixture of a substantial proportion of zero values and a skewed distribution of positive values. In the original formulation of this model, the natural logarithm of the positive values is assumed to follow a normal distribution with a constant variance parameter. In this article, we review and consider three extensions of this model, allowing the positive values to follow (a) a generalized gamma distribution, (b) a log-skew-normal distribution, and (c) a normal distribution after the Box-Cox transformation. We allow for the possibility of heteroscedasticity. Maximum likelihood estimation is shown to be conveniently implemented in SAS Proc NLMIXED. The performance of the methods is compared through applications to daily drinking records in a secondary data analysis from a randomized controlled trial of topiramate for alcohol dependence treatment. We find that all three models provide a significantly better fit than the log-normal model, and there exists strong evidence for heteroscedasticity. We also compare the three models by the likelihood ratio tests for non-nested hypotheses (Vuong(3)). The results suggest that the generalized gamma distribution provides the best fit, though no statistically significant differences are found in pairwise model comparisons.

  2. Preliminary evaluation of a micro-based repeated measures testing system

    Science.gov (United States)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  3. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  4. Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

    Science.gov (United States)

    Fukuda, Shinichi; Kawana, Keisuke; Yasuno, Yoshiaki; Oshika, Tetsuro

    2011-03-01

    To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. Nonrandomized clinical trial. Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Dimensional crossover in semiconductor nanostructures

    Science.gov (United States)

    McDonald, Matthew P.; Chatterjee, Rusha; Si, Jixin; Jankó, Boldizsár; Kuno, Masaru

    2016-08-01

    Recent advances in semiconductor nanostructure syntheses provide unprecedented control over electronic quantum confinement and have led to extensive investigations of their size- and shape-dependent optical/electrical properties. Notably, spectroscopic measurements show that optical bandgaps of one-dimensional CdSe nanowires are substantially (approximately 100 meV) lower than their zero-dimensional counterparts for equivalent diameters spanning 5-10 nm. But what, exactly, dictates the dimensional crossover of a semiconductor's electronic structure? Here we probe the one-dimensional to zero-dimensional transition of CdSe using single nanowire/nanorod absorption spectroscopy. We find that carrier electrostatic interactions play a fundamental role in establishing dimensional crossover. Moreover, the critical length at which this transition occurs is governed by the aspect ratio-dependent interplay between carrier confinement and dielectric contrast/confinement energies.

  6. Precision (Repeatability and Reproducibility and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

    Directory of Open Access Journals (Sweden)

    Yanjun Hua

    Full Text Available To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks, flat keratometry (Kf, mean keratometry (Km, J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw, coefficient of variation (CoV, test-retest repeatability (2.77Sw, and intraclass correlation coefficient (ICC. Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA.Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446. Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05. The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements.The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not

  7. Separating climate-induced mass transfers and instrumental effects from tectonic signal in repeated absolute gravity measurements

    Science.gov (United States)

    Van Camp, M.; Viron, O.; Avouac, J. P.

    2016-05-01

    We estimate the signature of the climate-induced mass transfers in repeated absolute gravity measurements based on satellite gravimetric measurements from the Gravity Recovery and Climate Experiment (GRACE) mission. We show results at the globe scale and compare them with repeated absolute gravity (AG) time behavior in three zones where AG surveys have been published: Northwestern Europe, Canada, and Tibet. For 10 yearly campaigns, the uncertainties affecting the determination of a linear gravity rate of change range 3-4 nm/s2/a in most cases, in the absence of instrumental artifacts. The results are consistent with what is observed for long-term repeated campaigns. We also discuss the possible artifact that can result from using short AG survey to determine the tectonic effects in a zone of high hydrological variability. We call into question the tectonic interpretation of several gravity changes reported from stations in Tibet, in particular the variation observed prior to the 2015 Gorkha earthquake.

  8. Accounting for uncertainty in volumes of seabed change measured with repeat multibeam sonar surveys

    Science.gov (United States)

    Schimel, Alexandre C. G.; Ierodiaconou, Daniel; Hulands, Lachlan; Kennedy, David M.

    2015-12-01

    Seafloors of unconsolidated sediment are highly dynamic features; eroding or accumulating under the action of tides, waves and currents. Assessing which areas of the seafloor experienced change and measuring the corresponding volumes involved provide insights into these important active sedimentation processes. Computing the difference between Digital Elevation Models (DEMs) obtained from repeat Multibeam Echosounders (MBES) surveys has become a common technique to identify these areas, but the uncertainty in these datasets considerably affects the estimation of the volumes displaced. The two main techniques used to take into account uncertainty in volume estimations are the limitation of calculations to areas experiencing a change in depth beyond a chosen threshold, and the computation of volumetric confidence intervals. However, these techniques are still in their infancy and, as a result, are often crude, seldom used or poorly understood. In this article, we explored a number of possible methodological advances to address this issue, including: (1) using the uncertainty information provided by the MBES data processing algorithm CUBE, (2) adapting fluvial geomorphology techniques for volume calculations using spatially variable thresholds and (3) volumetric histograms. The nearshore seabed off Warrnambool harbour - located in the highly energetic southwest Victorian coast, Australia - was used as a test site. Four consecutive MBES surveys were carried out over a four-months period. The difference between consecutive DEMs revealed an area near the beach experiencing large sediment transfers - mostly erosion - and an area of reef experiencing increasing deposition from the advance of a nearby sediment sheet. The volumes of sediment displaced in these two areas were calculated using the techniques described above, both traditionally and using the suggested improvements. We compared the results and discussed the applicability of the new methodological improvements

  9. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  10. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  11. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  12. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  13. A Correction for the Epsilon Approximate Test in Repeated Measures Designs with Two or More Independent Groups.

    Science.gov (United States)

    Lecoutre, Bruno

    1991-01-01

    The routine epsilon approximate test in repeated measures designs when the condition of circularity is unfulfilled uses an erroneous formula in the case of two or more groups. Because this may lead to underestimation of the deviation from circularity when the subject number is small, a correction is proposed. (Author/SLD)

  14. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients with...

  15. GSTM1 and APE1 genotypes affect arsenic-induced oxidative stress: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Quamruzzaman Quazi

    2007-12-01

    Full Text Available Abstract Background Chronic arsenic exposure is associated with an increased risk of skin, bladder and lung cancers. Generation of oxidative stress may contribute to arsenic carcinogenesis. Methods To investigate the association between arsenic exposure and oxidative stress, urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG was evaluated in a cohort of 97 women recruited from an arsenic-endemic region of Bangladesh in 2003. Arsenic exposure was measured in urine, toenails, and drinking water. Drinking water and urine samples were collected on three consecutive days. Susceptibility to oxidative stress was evaluated by genotyping relevant polymorphisms in glutathione-s transferase mu (GSTM1, human 8-oxoguanine glycosylase (hOGG1 and apurinic/apyrimidinic endonuclease (APE1 genes using the Taqman method. Data were analyzed using random effects Tobit regression to account for repeated measures and 8-OHdG values below the detection limit. Results A consistent negative effect for APE1 was observed across water, toenail and urinary arsenic models. APE1 148 glu/glu + asp/glu genotype was associated with a decrease in logged 8-OHdG of 0.40 (95%CI -0.73, -0.07 compared to APE1 148 asp/asp. An association between total urinary arsenic and 8-OHdG was observed among women with the GSTM1 null genotype but not in women with GSTM1 positive. Among women with GSTM1 null, a comparison of the second, third, and fourth quartiles of total urinary arsenic to the first quartile resulted in a 0.84 increase (95% CI 0.27, 1.42, a 0.98 increase (95% CI 033, 1.66 and a 0.85 increase (95% CI 0.27, 1.44 in logged 8-OHdG, respectively. No effects between 8-OHdG and toenail arsenic or drinking water arsenic were observed. Conclusion These results suggest the APE1 variant genotype decreases repair of 8-OHdG and that arsenic exposure is associated with oxidative stress in women who lack a functional GSTM1 detoxification enzyme.

  16. Pilot study: Assessing repeatability of the EcoWalk platform resistive pressure sensors to measure plantar pressure during barefoot standing

    Science.gov (United States)

    Zequera, Martha; Perdomo, Oscar; Wilches, Carlos; Vizcaya, Pedro

    2013-06-01

    Plantar pressure provides useful information to assess the feet's condition. These systems have emerged as popular tools in clinical environment. These systems present errors and no compensation information is presented by the manufacturer, leading to uncertainty in the measurements. Ten healthy subjects, 5 females and 5 males, were recruited. Lateral load distribution, antero-posterior load distribution, average pressure, contact area, and force were recorded. The aims of this study were to assess repeatability of the EcoWalk system and identify the range of pressure values observed in the normal foot. The coefficient of repeatability was less than 4% for all parameters considered.

  17. Influence of repeated washings with soap and synthetic detergents on pH and resident flora of the skin of forehead and forearm. Results of a cross-over trial in health probationers.

    Science.gov (United States)

    Korting, H C; Kober, M; Mueller, M; Braun-Falco, O

    1987-01-01

    Ten healthy individuals washed their forehead and forearm twice a day over consecutive periods of four weeks with soap and synthetic detergents or vice versa (cross-over design). In general the pH values were higher during the period when soap was applied (the mean pH differed by 0.3 units, p less than 0.01). As a rule the counts of coagulase-negative staphylococci were not much altered. The number of propionibacteria, however, was markedly higher when soap was used (p = 0.02 and 0.01 resp.). At the forehead there was a clear correlation between bacterial counts and skin pH both with propionibacteria (0.56, p less than 0.001) and staphylococci (0.51, p less than 0.001). At the forearm only the former proved true (0.24, p less than 0.05). Thus the skin pH seems to be open to long-standing changes according to the preferred washing habits which may also be of major influence on the composition of the cutaneous bacterial flora.

  18. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y.; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%) however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  19. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    Directory of Open Access Journals (Sweden)

    Semra Tiryaki Demir

    2014-08-01

    Full Text Available Objectives: Comparison of central corneal thickness (CCT measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG, 41 patients with ocular hypertension (OHT, and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000 were used for measurement of CCT. ANOVA (Turkey test was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p0.05. CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001. Repeatability of ultrasonic pachymetry for same observer was (ICC value 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7

  20. Making crossovers during meiosis.

    Science.gov (United States)

    Whitby, M C

    2005-12-01

    Homologous recombination (HR) is required to promote both correct chromosome segregation and genetic variation during meiosis. For this to be successful recombination intermediates must be resolved to generate reciprocal exchanges or 'crossovers' between the homologous chromosomes (homologues) during the first meiotic division. Crossover recombination promotes faithful chromosome segregation by establishing connections (chiasmata) between the homologues, which help guide their proper bipolar alignment on the meiotic spindle. Recent studies of meiotic recombination in both the budding and fission yeasts have established that there are at least two pathways for generating crossovers. One pathway involves the resolution of fully ligated four-way DNA junctions [HJs (Holliday junctions)] by an as yet unidentified endonuclease. The second pathway appears to involve the cleavage of the precursors of ligated HJs, namely displacement (D) loops and unligated/nicked HJs, by the Mus81-Eme1/Mms4 endonuclease.

  1. Quantum Key Distribution over Probabilistic Quantum Repeaters

    CERN Document Server

    Amirloo, Jeyran; Majedi, A Hamed

    2010-01-01

    A feasible route towards implementing long-distance quantum key distribution (QKD) systems relies on probabilistic schemes for entanglement distribution and swapping as proposed in the work of Duan, Lukin, Cirac, and Zoller (DLCZ) [Nature 414, 413 (2001)]. Here, we calculate the conditional throughput and fidelity of entanglement for DLCZ quantum repeaters, by accounting for the DLCZ self-purification property, in the presence of multiple excitations in the ensemble memories as well as loss and other sources of inefficiency in the channel and measurement modules. We then use our results to find the generation rate of secure key bits for QKD systems that rely on DLCZ quantum repeaters. We compare the key generation rate per logical memory employed in the two cases of with and without a repeater node. We find the cross-over distance beyond which the repeater system outperforms the non-repeater one. That provides us with the optimum inter-node distancing in quantum repeater systems. We also find the optimal exci...

  2. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah

    2016-01-01

    Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement...... of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume...... and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema....

  3. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  4. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    Directory of Open Access Journals (Sweden)

    Maria Magdalena Dresler

    2017-06-01

    Full Text Available Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.

  5. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration.

    Science.gov (United States)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie; Sagoo, Mandeep S; Tufail, Adnan; Balaggan, Kamaljit S; Patel, Praveen J

    2017-05-01

    The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). A prospective study consisting of patients with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS macular subfields. Repeatability was calculated according to methods described by Bland and Altman. 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm). The repeatability this subfield, expressed as a percentage of the mean central macular subfield thickness, was 23.2%. The percentage repeatability of the other macular subfields ranged from 13.2% to 28.7%. The intrasession coefficient of repeatability of choroidal thickness of the central macular subfield was 57.2 μm with a mean choroidal thickness (±SD) of 181 μm (±15.8 μm). This study suggests that a change >23.2% of retinal thickness and 57.2 μm choroidal thickness in the central macular subfield is required to distinguish true clinical change from measurement variability when using the DRI OCT-1 device to manage patients with nAMD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    OpenAIRE

    Semra Tiryaki Demir; Mahmut Odabaşı; Mehmet Ersin Oba; Ayşe Burcu Dirim; Efe Can; Orhan Kara

    2014-01-01

    Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) ...

  7. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  8. Incomplete quality of life data in lung transplant research: comparing cross sectional, repeated measures ANOVA, and multi-level analysis

    Directory of Open Access Journals (Sweden)

    van der Bij Wim

    2005-09-01

    Full Text Available Abstract Background In longitudinal studies on Health Related Quality of Life (HRQL it frequently occurs that patients have one or more missing forms, which may cause bias, and reduce the sample size. Aims of the present study were to address the problem of missing data in the field of lung transplantation (LgTX and HRQL, to compare results obtained with different methods of analysis, and to show the value of each type of statistical method used to summarize data. Methods Results from cross-sectional analysis, repeated measures on complete cases (ANOVA, and a multi-level analysis were compared. The scores on the dimension 'energy' of the Nottingham Health Profile (NHP after transplantation were used to illustrate the differences between methods. Results Compared to repeated measures ANOVA, the cross-sectional and multi-level analysis included more patients, and allowed for a longer period of follow-up. In contrast to the cross sectional analyses, in the complete case analysis, and the multi-level analysis, the correlation between different time points was taken into account. Patterns over time of the three methods were comparable. In general, results from repeated measures ANOVA showed the most favorable energy scores, and results from the multi-level analysis the least favorable. Due to the separate subgroups per time point in the cross-sectional analysis, and the relatively small number of patients in the repeated measures ANOVA, inclusion of predictors was only possible in the multi-level analysis. Conclusion Results obtained with the various methods of analysis differed, indicating some reduction of bias took place. Multi-level analysis is a useful approach to study changes over time in a data set where missing data, to reduce bias, make efficient use of available data, and to include predictors, in studies concerning the effects of LgTX on HRQL.

  9. Repeated Microsphere Delivery for Serial Measurement of Regional Blood Perfusion in the Chronically Instrumented, Conscious Canine

    Science.gov (United States)

    Bartoli, Carlo R.; Okabe, Kazunori; Akiyama, Ichiro; Coull, Brent; Godleski, John J.

    2008-01-01

    INTRODUCTION For chronic, repeated hemodynamic studies in conscious dogs, we designed and tested a chronically instrumented canine, microsphere delivery model. The goals of this study were to investigate the accuracy of repeated estimations of blood perfusion using fluorescent-labeled microspheres and to develop and validate a chronic preparation that permits consecutive estimations in the same conscious animal over an extended protocol. METHODS Via thoracotomy, 9 dogs were instrumented with left atrial appendage and aortic vascular access catheters connected to subcutaneous vascular access ports (VAPs). Four animals received 7 serial injections of 1.6 million 15μm microspheres (total: 11.2 million), and five animals received 8 serial injections of 2.25 million microspheres (total: 18 million) over the course of 11 or 18 weeks. RESULTS All catheters have remained bidirectionally patent during protocol for 14.9±0.8 (Mean±SEM) weeks. Sphere accumulation did not significantly alter global myocardial (p=0.69, p=0.25), renal (p=0.92, p=0.12), hepatic (p=0.84, p=0.32), or splenic (p=0.33, p=0.70) blood perfusion in either set of animals. CONCLUSIONS Catheters remained bidirectionally patent for months, did not interfere with the hemodynamic responses of the preparation, and allowed repeat percutaneous injection of microspheres and withdrawal of reference arterial blood from within conscious canines. Eight serial injections totaling 18 million microspheres over 18 weeks did not alter regional myocardial, hepatic, renal, or splenic blood flow. This dependable, chronic, percutaneous arterial access preparation provides a means for examining acute and long-term effects of pathophysiological, pharmaceutical, and environmental influences on regional arterial blood perfusion in conscious, large animals. PMID:17632127

  10. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  11. Persistent repeated measurements by magnetic resonance spectroscopy demonstrate minimal hepatic encephalopathy: a case report.

    Science.gov (United States)

    Scheau, C; Popa, G A; Ghergus, A E; Preda, E M; Capsa, R A; Lupescu, I G

    2013-09-15

    Minimal Hepatic Encephalopathy (MHE), previously referred to as infraclinical or subclinical is a precursor in the development of clinical hepatic encephalopathy (HE). The demonstration of MHE is done through neuropsychological testing in the absence of clinical evidence of HE, patients showing only a mild cognitive impairment. Neuropsychological tests employed consist of Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) and portosystemic encephalopathy (PSE) test score. Unfortunately, there are numerous occasions when the tests prove irrelevant: in the situation of inexperienced investigators, the patient's poor education, vision problems or concurring central nervous system disease, all of which may delay or deviate from the correct diagnosis.

  12. Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy

    Institute of Scientific and Technical Information of China (English)

    LI De-jiao; WANG Ning-li; CHEN Shu; LI Shu-ning; MU Da-peng; WANG Tao

    2009-01-01

    Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia. Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM).Methods A fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator.Results On a scale of 1 mm, the greatest indicating error was 40 μm; the mean largest indicating error of 1 mm scale from the 10 images was (26±14) μm; on a scale of 11 mm, the greatest indicating error was 70 μo; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 μm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were-0.41 mm to 0.48 mm and -0.59 mm to 0.58 ram, respectively.Conclusion The full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct

  13. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    DEFF Research Database (Denmark)

    Miles, James Edward; Jensen, Bente Rona; Kirpensteijn, Jolle

    2013-01-01

    Objective-To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind limbs. An...... and applied criteria. The TT-TG offset distance has potential as an objective assessment of alignment of the distal portion of the quadriceps mechanism; its use as an aid in case selection for corrective femoral osteotomy among dogs with medial patellar luxation warrants investigation....

  14. Intergenic and repeat transcription in human, chimpanzee and macaque brains measured by RNA-Seq.

    Directory of Open Access Journals (Sweden)

    Augix Guohua Xu

    Full Text Available Transcription is the first step connecting genetic information with an organism's phenotype. While expression of annotated genes in the human brain has been characterized extensively, our knowledge about the scope and the conservation of transcripts located outside of the known genes' boundaries is limited. Here, we use high-throughput transcriptome sequencing (RNA-Seq to characterize the total non-ribosomal transcriptome of human, chimpanzee, and rhesus macaque brain. In all species, only 20-28% of non-ribosomal transcripts correspond to annotated exons and 20-23% to introns. By contrast, transcripts originating within intronic and intergenic repetitive sequences constitute 40-48% of the total brain transcriptome. Notably, some repeat families show elevated transcription. In non-repetitive intergenic regions, we identify and characterize 1,093 distinct regions highly expressed in the human brain. These regions are conserved at the RNA expression level across primates studied and at the DNA sequence level across mammals. A large proportion of these transcripts (20% represents 3'UTR extensions of known genes and may play roles in alternative microRNA-directed regulation. Finally, we show that while transcriptome divergence between species increases with evolutionary time, intergenic transcripts show more expression differences among species and exons show less. Our results show that many yet uncharacterized evolutionary conserved transcripts exist in the human brain. Some of these transcripts may play roles in transcriptional regulation and contribute to evolution of human-specific phenotypic traits.

  15. A Description of Quasar Variability Measured Using Repeated SDSS and POSS Imaging

    CERN Document Server

    MacLeod, Chelsea L; Sesar, Branimir; de Vries, Wim; Kochanek, Christopher S; Kelly, Brandon C; Becker, Andrew C; Lupton, Robert H; Hall, Patrick B; Richards, Gordon T; Anderson, Scott F; Schneider, Donald P

    2011-01-01

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 34,727 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along stripe 82 (S82), whereas the remaining ~25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000A to 6000A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic time scale and an asymptotic variabilit...

  16. Estimation of spatial patterns of urban air pollution over a 4-week period from repeated 5-min measurements

    Science.gov (United States)

    Gillespie, Jonathan; Masey, Nicola; Heal, Mathew R.; Hamilton, Scott; Beverland, Iain J.

    2017-02-01

    Determination of intra-urban spatial variations in air pollutant concentrations for exposure assessment requires substantial time and monitoring equipment. The objective of this study was to establish if short-duration measurements of air pollutants can be used to estimate longer-term pollutant concentrations. We compared 5-min measurements of black carbon (BC) and particle number (PN) concentrations made once per week on 5 occasions, with 4 consecutive 1-week average nitrogen dioxide (NO2) concentrations at 18 locations at a range of distances from busy roads in Glasgow, UK. 5-min BC and PN measurements (averaged over the two 5-min periods at the start and end of a week) explained 40-80%, and 7-64% respectively, of spatial variation in the intervening 1-week NO2 concentrations for individual weeks. Adjustment for variations in background concentrations increased the percentage of explained variation in the bivariate relationship between the full set of NO2 and BC measurements over the 4-week period from 28% to 50% prior to averaging of repeat measurements. The averages of five 5-min BC and PN measurements made over 5 weeks explained 75% and 33% respectively of the variation in average 1-week NO2 concentrations over the same period. The relatively high explained variation observed between BC and NO2 measured on different time scales suggests that, with appropriate steps to correct or average out temporal variations, repeated short-term measurements can be used to provide useful information on longer-term spatial patterns for these traffic-related pollutants.

  17. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus.

    Science.gov (United States)

    Jager-Wittenaar, H; Dijkstra, P U; Vissink, A; van Oort, R P; Roodenburg, J L N

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this study was to analyse the variation in mouth-opening measurements in patients treated for head and neck cancer, with and without trismus. Maximal mouth opening was measured in 120 patients in two sessions of three repeated measurements by one observer. To analyse the influence of interobserver variation on mouth-opening measurements a subgroup of 30 patients was measured by a second observer. The standard deviation of the six measurements per patient was used as the variation in measurements of maximal mouth opening. No significant difference was found in maximal mouth opening in patients with (n=33) or without (n=87) trismus. The interobserver intraclass correlation coefficient (ICC) was 0.98. Intraobserver ICC and intersession ICC reliabilities both were 0.99. The variation in the mean values of the three measurements was only slightly smaller than the variation of the single measurements. Variation in maximal mouth opening in patients with trismus does not differ from variation in maximal mouth opening in patients without trismus. Interobserver variation is limited.

  18. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  19. A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    MacLeod, Chelsea L.; Ivezic, Zeljko; Becker, Andrew C.; Anderson, Scott F. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Sesar, Branimir [Division of Physics, Mathematics and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); De Vries, Wim [Department of Physics, University of California, One Shields Ave, Davis, CA 95616 (United States); Kochanek, Christopher S. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Kelly, Brandon C. [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Lupton, Robert H. [Department of Astrophysical Sciences, Princeton University, Princeton, New Jersey 08544 (United States); Hall, Patrick B. [Department of Physics and Astronomy, York University, Toronto, ON M3J 1P3 (Canada); Richards, Gordon T. [Department of Physics, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Schneider, Donald P. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States)

    2012-07-10

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining {approx}25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 A to 6000 A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of {approx}5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

  20. Application of genetic algorithm with approximation crossover strategy to ambiguity resolution in PD radar

    Institute of Scientific and Technical Information of China (English)

    ZhangGong; ZhuZhaoda; ZhuNingyi

    2003-01-01

    The genetic algorithm (GA) designed as a general optimization method was applied to the ambiguity resolution of pulse Doppler (PD) radar. The fitness, based on squared error for multi-PRF (pulse repeat frequency) consecutive ordered ranges, was designed. The crossover operator and the conditions of ending in GA were discussed. The relations among the probability of ambiguity resolution of this algorithm, the measurement error and the computational efficiency were analyzed.Simulation results show the GA ambiguity resolution algorithm does better than the sliding window algorithm on the probability of ambiguity resolution.

  1. Correcting for GPS Multipath Error in LIDAR Surveys Using Crossover Analysis

    Science.gov (United States)

    Borsa, A. A.; Bills, B. G.; Fricker, H. A.; Minster, J. B.

    2003-12-01

    The quality of the range measurement from an airborne Light Detection and Ranging (LIDAR) survey is largely dependent on the accuracy of the GPS trajectory for the aircraft. GPS elevation error - which today is largely due to multipath effects at the aircraft and the GPS base station - contributes a major portion of the LIDAR vertical error budget. The usual practice of quoting an RMS value for the GPS component of the error budget implies that GPS noise is Gaussian, yet the true nature of the noise signal is time-varying with significant power at long periods. GPS noise with a 3-cm RMS can easily have more than 10 cm of total variability on a time scale of tens of minutes to several hours. We show examples from an airborne LIDAR survey over the open-pit Hector Mine where repeated flyovers of an area used for ground truth revealed large elevation biases between passes that could not be resolved by adjusting the (non-GPS) parameters of the LIDAR system. As part of the post-processing of a large kinematic GPS survey of the salar de Uyuni, Bolivia, we have developed an algorithm to correct time-varying GPS error using elevation mismatches at crossovers between vehicle paths. The survey was originally designed to incorporate a large number of crossovers for the purpose of determining survey repeatability, and we were later able to exploit the crossover difference observations to solve for a model of the actual error signal generating those differences. We give results from tests with synthetic noise and topography data indicating that this method removes more than two-thirds of the added noise from the topographic signal, and we show the excellent results obtained for the salar de Uyuni survey data. We believe that airborne LIDAR surveys incorporating crossovers at regular intervals can also benefit from the application of this algorithm.

  2. Repeatability of Cone Spacing Measures in Eyes With Inherited Retinal Degenerations

    National Research Council Canada - National Science Library

    Zayit-Soudry, Shiri; Sippl-Swezey, Nicolas; Porco, Travis C; Lynch, Stephanie K; Syed, Reema; Ratnam, Kavitha; Menghini, Moreno; Roorda, Austin J; Duncan, Jacque L

    2015-01-01

    ...)-derived cone spacing measures in eyes with inherited retinal degenerations (IRD) and in normal eyes. Twenty IRD patients and 10 visually normal subjects underwent AOSLO imaging at two visits separated by no more than 1 month...

  3. Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries.

    Science.gov (United States)

    Vuong, Vivian S; Moisseiev, Elad; Cunefare, David; Farsiu, Sina; Moshiri, Ala; Yiu, Glenn

    2016-09-01

    To assess the reliability of manual choroidal thickness measurements by comparing different posterior boundary definitions of the choroidal-scleral junction on enhanced depth imaging optical coherence tomography (EDI-OCT). Reliability analysis. Two graders marked the choroidal-scleral junction with segmentation software using different posterior boundaries: (1) the outer border of the choroidal vessel lumen, (2) the outer border of the choroid stroma, and (3) the inner border of the sclera, to measure the vascular choroidal thickness (VCT), stromal choroidal thickness (SCT), and total choroidal thickness (TCT), respectively. Measurements were taken at 0.5-mm intervals from 1.5 mm nasal to 1.5 mm temporal to the fovea, and averaged continuously across the central 3 mm of the macula. Intraclass correlation coefficient (ICC) and coefficient of reliability (CR) were compared to assess intergrader and intragrader reliability. Choroidal thickness measurements varied significantly with different posterior boundaries (P choroidal-scleral junction visibility was Choroidal thickness measurements are more reproducible when measured to the border of the choroid stroma (SCT) than the vascular lumen (VCT) or sclera (TCT). Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Decomposing Multifractal Crossovers

    Science.gov (United States)

    Nagy, Zoltan; Mukli, Peter; Herman, Peter; Eke, Andras

    2017-01-01

    Physiological processes—such as, the brain's resting-state electrical activity or hemodynamic fluctuations—exhibit scale-free temporal structuring. However, impacts common in biological systems such as, noise, multiple signal generators, or filtering by transport function, result in multimodal scaling that cannot be reliably assessed by standard analytical tools that assume unimodal scaling. Here, we present two methods to identify breakpoints or crossovers in multimodal multifractal scaling functions. These methods incorporate the robust iterative fitting approach of the focus-based multifractal formalism (FMF). The first approach (moment-wise scaling range adaptivity) allows for a breakpoint-based adaptive treatment that analyzes segregated scale-invariant ranges. The second method (scaling function decomposition method, SFD) is a crossover-based design aimed at decomposing signal constituents from multimodal scaling functions resulting from signal addition or co-sampling, such as, contamination by uncorrelated fractals. We demonstrated that these methods could handle multimodal, mono- or multifractal, and exact or empirical signals alike. Their precision was numerically characterized on ideal signals, and a robust performance was demonstrated on exemplary empirical signals capturing resting-state brain dynamics by near infrared spectroscopy (NIRS), electroencephalography (EEG), and blood oxygen level-dependent functional magnetic resonance imaging (fMRI-BOLD). The NIRS and fMRI-BOLD low-frequency fluctuations were dominated by a multifractal component over an underlying biologically relevant random noise, thus forming a bimodal signal. The crossover between the EEG signal components was found at the boundary between the δ and θ bands, suggesting an independent generator for the multifractal δ rhythm. The robust implementation of the SFD method should be regarded as essential in the seamless processing of large volumes of bimodal fMRI-BOLD imaging data for

  5. Decomposing Multifractal Crossovers

    Directory of Open Access Journals (Sweden)

    Zoltan Nagy

    2017-07-01

    Full Text Available Physiological processes—such as, the brain's resting-state electrical activity or hemodynamic fluctuations—exhibit scale-free temporal structuring. However, impacts common in biological systems such as, noise, multiple signal generators, or filtering by transport function, result in multimodal scaling that cannot be reliably assessed by standard analytical tools that assume unimodal scaling. Here, we present two methods to identify breakpoints or crossovers in multimodal multifractal scaling functions. These methods incorporate the robust iterative fitting approach of the focus-based multifractal formalism (FMF. The first approach (moment-wise scaling range adaptivity allows for a breakpoint-based adaptive treatment that analyzes segregated scale-invariant ranges. The second method (scaling function decomposition method, SFD is a crossover-based design aimed at decomposing signal constituents from multimodal scaling functions resulting from signal addition or co-sampling, such as, contamination by uncorrelated fractals. We demonstrated that these methods could handle multimodal, mono- or multifractal, and exact or empirical signals alike. Their precision was numerically characterized on ideal signals, and a robust performance was demonstrated on exemplary empirical signals capturing resting-state brain dynamics by near infrared spectroscopy (NIRS, electroencephalography (EEG, and blood oxygen level-dependent functional magnetic resonance imaging (fMRI-BOLD. The NIRS and fMRI-BOLD low-frequency fluctuations were dominated by a multifractal component over an underlying biologically relevant random noise, thus forming a bimodal signal. The crossover between the EEG signal components was found at the boundary between the δ and θ bands, suggesting an independent generator for the multifractal δ rhythm. The robust implementation of the SFD method should be regarded as essential in the seamless processing of large volumes of bimodal f

  6. The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography

    Science.gov (United States)

    Chang, Pingjun; Li, Jin; Savini, Giacomo; Huang, Jinhai; Huang, Shenghai; Zhao, Yinying; Liao, Na; Lin, Lei; Yu, Xiaoyu; Zhao, Yun-e

    2015-01-01

    Purpose To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. Methods Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening. Results PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements. Conclusion SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex. PMID:26600254

  7. Repeatability of measurements: Non-Hermitian observables and quantum Coriolis force

    Science.gov (United States)

    Gardas, Bartłomiej; Deffner, Sebastian; Saxena, Avadh

    2016-08-01

    A noncommuting measurement transfers, via the apparatus, information encoded in a system's state to the external "observer." Classical measurements determine properties of physical objects. In the quantum realm, the very same notion restricts the recording process to orthogonal states as only those are distinguishable by measurements. Therefore, even a possibility to describe physical reality by means of non-Hermitian operators should volens nolens be excluded as their eigenstates are not orthogonal. Here, we show that non-Hermitian operators with real spectra can be treated within the standard framework of quantum mechanics. Furthermore, we propose a quantum canonical transformation that maps Hermitian systems onto non-Hermitian ones. Similar to classical inertial forces this map is accompanied by an energetic cost, pinning the system on the unitary path.

  8. Mediation of the Relationship between Maternal Phthalate Exposure and Preterm Birth by Oxidative Stress with Repeated Measurements across Pregnancy.

    Science.gov (United States)

    Ferguson, Kelly K; Chen, Yin-Hsiu; VanderWeele, Tyler J; McElrath, Thomas F; Meeker, John D; Mukherjee, Bhramar

    2017-03-01

    Mediation analysis is useful for understanding mechanisms and has been used minimally in the study of the environment and disease. We examined mediation of the association between phthalate exposure during pregnancy and preterm birth by oxidative stress. This nested case-control study of preterm birth (n = 130 cases, 352 controls) included women who delivered in Boston, Massachusestts, from 2006 through 2008. Phthalate metabolites and 8-isoprostane, an oxidative stress biomarker, were measured in urine from three visits in pregnancy. We applied four counterfactual mediation methods: method 1, utilizing exposure and mediator averages; method 2, using averages but allowing for an exposure-mediator interaction; method 3, incorporating longitudinal measurements of the exposure and mediator; and method 4, using longitudinal measurements and allowing for an exposure-mediator interaction. We observed mediation of the associations between phthalate metabolites and all preterm birth by 8-isoprostane, with the greatest estimated proportion mediated observed for spontaneous preterm births specifically. Fully utilizing repeated measures of the exposure and mediator improved precision of indirect (i.e., mediated) effect estimates, and including an exposure-mediator interaction increased the estimated proportion mediated. For example, for mono(2-ethyl-carboxy-propyl) phthalate (MECPP), a metabolite of di(2-ethylhexyl) phthalate (DEHP), the percent of the total effect mediated by 8-isoprostane increased from 47% to 60% with inclusion of an exposure-mediator interaction term, in reference to a total adjusted odds ratio of 1.67 or 1.48, respectively. This demonstrates mediation of the phthalate-preterm birth relationship by oxidative stress, and the utility of complex regression models in capturing mediated associations when repeated measures of exposure and mediator are available and an exposure-mediator interaction may exist. Citation: Ferguson KK, Chen YH, VanderWeele TJ, Mc

  9. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Wheeler, Kevin; Hensley, Scott; Lou, Yunling

    2004-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeatpass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV or minimally piloted vehicle (MPV).

  10. Repeated measurements of P retention in ponies fed rations with various Ca:P ratios

    NARCIS (Netherlands)

    van Doorn, D A; Schaafstra, F J W C; Wouterse, H; Everts, H; Estepa, J C; Aguilera-Tejero, E; Beynen, A C

    2014-01-01

    This study addresses the question of whether feeding rations rich in P for a period of up to 42 d induces a positive P balance in adult ponies. Biochemical bone markers and parathyroid hormone (PTH; intact as well as whole PTH) were measured to obtain clues as to the effect of P loading on bone meta

  11. Repeated measures of urinary oxidative stress biomarkers during pregnancy and preterm birth.

    Science.gov (United States)

    Ferguson, Kelly K; McElrath, Thomas F; Chen, Yin-Hsiu; Loch-Caruso, Rita; Mukherjee, Bhramar; Meeker, John D

    2015-02-01

    The purpose of this study was to investigate oxidative stress as a mechanism of preterm birth in human subjects; we examined associations between urinary biomarkers of oxidative stress that were measured at multiple time points during pregnancy and preterm birth. This nested case-control study included 130 mothers who delivered preterm and 352 mothers who delivered term who were originally recruited as part of an ongoing prospective birth cohort at Brigham and Women's Hospital. Two biomarkers that included 8-hydroxydeoxyguanosine (8-OHdG) and 8-isoprostane were measured in urine samples that were collected at up to 4 time points (median 10, 18, 26, and 35 weeks) during gestation. Urinary concentrations of 8-isoprostane and 8-OHdG decreased and increased, respectively, as pregnancy progressed. Average levels of 8-isoprostane across pregnancy were associated with increased odds of spontaneous preterm birth (adjusted odds ratio, 6.25; 95% confidence interval, 2.86-13.7), and associations were strongest with levels measured later in pregnancy. Average levels of 8-OHdG were protective against overall preterm birth (adjusted odds ratio, 0.19; 95% confidence interval, 0.10-0.34), and there were no apparent differences in the protective effect in cases of spontaneous preterm birth compared with cases of placental origin. Odds ratios for overall preterm birth were more protective in association with urinary 8-OHdG concentrations that were measured early in pregnancy. Maternal oxidative stress may be an important contributor to preterm birth, regardless of subtype and timing of exposure during pregnancy. The 2 biomarkers that were measured in the present study had opposite associations with preterm birth; an improved understanding of what each represents may help to identify more precisely important mechanisms in the pathway to preterm birth. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig.

  13. Extended fluctuation theorems for repeated measurements and feedback within Hamiltonian framework

    Energy Technology Data Exchange (ETDEWEB)

    Lahiri, Sourabh, E-mail: sourabhlahiri@gmail.com [Laboratoire de Physico-Chimie Théorique, ESPCI, 10 rue Vauquelin, F-75231 Paris (France); Jayannavar, A.M. [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005 (India)

    2016-04-29

    We derive the extended fluctuation theorems in presence of multiple measurements and feedback, when the system is governed by Hamiltonian dynamics. We use only the forward phase space trajectories in the derivation. However, to obtain an expression for the efficacy parameter, we must necessarily use the notion of reverse trajectory. Our results show that the correction term appearing in the exponent of the extended fluctuation theorems is non-unique, whereas the physical meaning of the efficacy parameter is unique. - Highlights: • Extended Fluctuation Theorems under multiple measurements and feedback have been derived using Hamiltonian dynamics. • We prove the theorems without using the notion of reverse trajectory. • We show that the correction terms are not unique. • The efficacy parameter is shown to have a unique physical meaning.

  14. Composite tube and plate manufacturing repeatability as determined by precision measurements of thermal strain

    Science.gov (United States)

    Riddle, Lenn A.; Tucker, James R.; Bluth, A. Marcel

    2013-09-01

    Composite materials often carry the reputation of demonstrating high variability in critical material properties. The JWST telescope metering structure is fabricated of several thousand separate composite piece parts. The stringent dimensional stability requirements on the metering structure require the critical thermal strain response of every composite piece be verified either at the billet or piece part level. JWST is a unique composite space structure in that it has required the manufacturing of several hundred composite billets that cover many lots of prepreg and many years of fabrication. The flight billet thermal expansion acceptance criteria limits the coefficient of thermal expansion (CTE) to a tolerance ranging between +/-0.014 ppm/K to +/-0.04 ppm/K around a prescribed nominal when measured from 293 K down to 40 K. The different tolerance values represent different material forms including flat plates and different tube cross-section dimensions. A precision measurement facility was developed that could measure at the required accuracy and at a pace that supported the composite part fabrication rate. The test method and facility is discussed and the results of a statistical process analysis of the flight composite billets are surveyed.

  15. Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

    Directory of Open Access Journals (Sweden)

    Raza Abid

    2010-04-01

    Full Text Available Abstract Background Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden, is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers. Methods Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study. Results The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb, although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p Conclusions The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.

  16. Reliability of plasma lipopolysaccharide-binding protein (LBP) from repeated measures in healthy adults.

    Science.gov (United States)

    Citronberg, Jessica S; Wilkens, Lynne R; Lim, Unhee; Hullar, Meredith A J; White, Emily; Newcomb, Polly A; Le Marchand, Loïc; Lampe, Johanna W

    2016-09-01

    Plasma lipopolysaccharide-binding protein (LBP), a measure of internal exposure to bacterial lipopolysaccharide, has been associated with several chronic conditions and may be a marker of chronic inflammation; however, no studies have examined the reliability of this biomarker in a healthy population. We examined the temporal reliability of LBP measured in archived samples from participants in two studies. In Study one, 60 healthy participants had blood drawn at two time points: baseline and follow-up (either three, six, or nine months). In Study two, 24 individuals had blood drawn three to four times over a seven-month period. We measured LBP in archived plasma by ELISA. Test-retest reliability was estimated by calculating the intraclass correlation coefficient (ICC). Plasma LBP concentrations showed moderate reliability in Study one (ICC 0.60, 95 % CI 0.43-0.75) and Study two (ICC 0.46, 95 % CI 0.26-0.69). Restricting the follow-up period improved reliability. In Study one, the reliability of LBP over a three-month period was 0.68 (95 % CI: 0.41-0.87). In Study two, the ICC of samples taken ≤seven days apart was 0.61 (95 % CI 0.29-0.86). Plasma LBP concentrations demonstrated moderate test-retest reliability in healthy individuals with reliability improving over a shorter follow-up period.

  17. Global sensitivity analysis for repeated measures studies with informative drop-out: A semi-parametric approach.

    Science.gov (United States)

    Scharfstein, Daniel; McDermott, Aidan; Díaz, Iván; Carone, Marco; Lunardon, Nicola; Turkoz, Ibrahim

    2017-05-23

    In practice, both testable and untestable assumptions are generally required to draw inference about the mean outcome measured at the final scheduled visit in a repeated measures study with drop-out. Scharfstein et al. (2014) proposed a sensitivity analysis methodology to determine the robustness of conclusions within a class of untestable assumptions. In their approach, the untestable and testable assumptions were guaranteed to be compatible; their testable assumptions were based on a fully parametric model for the distribution of the observable data. While convenient, these parametric assumptions have proven especially restrictive in empirical research. Here, we relax their distributional assumptions and provide a more flexible, semi-parametric approach. We illustrate our proposal in the context of a randomized trial for evaluating a treatment of schizoaffective disorder. © 2017, The International Biometric Society.

  18. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  19. Assessment of individual agreements with repeated measurements based on generalized confidence intervals.

    Science.gov (United States)

    Quiroz, Jorge; Burdick, Richard K

    2009-01-01

    Individual agreement between two measurement systems is determined using the total deviation index (TDI) or the coverage probability (CP) criteria as proposed by Lin (2000) and Lin et al. (2002). We used a variance component model as proposed by Choudhary (2007). Using the bootstrap approach, Choudhary (2007), and generalized confidence intervals, we construct bounds on TDI and CP. A simulation study was conducted to assess whether the bounds maintain the stated type I error probability of the test. We also present a computational example to demonstrate the statistical methods described in the paper.

  20. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms

    Directory of Open Access Journals (Sweden)

    Clark Kogan

    2016-01-01

    Full Text Available In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  1. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms.

    Science.gov (United States)

    Kogan, Clark; Kalachev, Leonid; Van Dongen, Hans P A

    2016-01-01

    In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables) by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary) response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  2. The clinical applicability of a daily summary of patients' self-reported postoperative pain-A repeated measure analysis.

    Science.gov (United States)

    Wikström, Lotta; Eriksson, Kerstin; Fridlund, Bengt; Nilsson, Mats; Årestedt, Kristofer; Broström, Anders

    2017-03-23

    (i) To determine whether a central tendency, median, based on patients' self-rated pain is a clinically applicable daily measure to show patients' postoperative pain on the first day after major surgery (ii) and to determine the number of self-ratings required for the calculation of this measure. Perioperative pain traits in medical records are difficult to overview. The clinical applicability of a daily documented summarising measure of patients' self-rated pain scores is little explored. A repeated measure design was carried out at three Swedish country hospitals. Associations between the measures were analysed with nonparametric statistical methods; systematic and individual group changes were analysed separately. Measure I: pain scores at rest and activity postoperative day 1; measure II: retrospective average pain from postoperative day 1. The sample consisted of 190 general surgery patients and 289 orthopaedic surgery patients with a mean age of 65; 56% were men. Forty-four percent had a pre-operative daily intake of analgesia, and 77% used postoperative opioids. A range of 4-9 pain scores seem to be eligible for the calculation of the daily measures of pain. Rank correlations for individual median scores, based on four ratings, vs. retrospective self-rated average pain, were moderate and strengthened with increased numbers of ratings. A systematic group change towards a higher level of reported retrospective pain was significant. The median values were clinically applicable daily measures. The risk of obtaining a higher value than was recalled by patients seemed to be low. Applicability increased with increased frequency of self-rated pain scores and with high-quality pain assessments. The documenting of daily median pain scores at rest and during activity could constitute the basis for obtaining patients' experiences by showing their pain severity trajectories. The measures could also be an important key to predicting postoperative health

  3. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  4. Repeated measures of inflammation and oxidative stress biomarkers in preeclamptic and normotensive pregnancies.

    Science.gov (United States)

    Ferguson, Kelly K; Meeker, John D; McElrath, Thomas F; Mukherjee, Bhramar; Cantonwine, David E

    2017-05-01

    Preeclampsia is a prevalent and enigmatic disease, in part characterized by poor remodeling of the spiral arteries. However, preeclampsia does not always clinically present when remodeling has failed to occur. Hypotheses surrounding the "second hit" that is necessary for the clinical presentation of the disease focus on maternal inflammation and oxidative stress. Yet, the studies to date that have investigated these factors have used cross-sectional study designs or small study populations. In the present study, we sought to explore longitudinal trajectories, beginning early in gestation, of a panel of inflammation and oxidative stress markers in women who went on to have preeclamptic or normotensive pregnancies. We examined 441 subjects from the ongoing LIFECODES prospective birth cohort, which included 50 mothers who experienced preeclampsia and 391 mothers with normotensive pregnancies. Participants provided urine and plasma samples at 4 time points during gestation (median, 10, 18, 26, and 35 weeks) that were analyzed for a panel of oxidative stress and inflammation markers. Oxidative stress biomarkers included 8-isoprostane and 8-hydroxydeoxyguanosine. Inflammation biomarkers included C-reactive protein, the cytokines interleukin-1β, -6, and -10, and tumor necrosis factor-α. We created Cox proportional hazard models to calculate hazard ratios based on time of preeclampsia diagnosis in association with biomarker concentrations at each of the 4 study visits. In adjusted models, hazard ratios of preeclampsia were significantly (Pinflammation biomarkers that were measured at visit 2 (median, 18 weeks; hazard ratios, 1.31-1.83, in association with an interquartile range increase in biomarker). Hazard ratios at this time point were the most elevated for C-reactive protein, for interleukin-1β, -6, and -10, and for the oxidative stress biomarker 8-isoprostane (hazard ratio, 1.68; 95% confidence interval, 1.14-2.48) compared to other time points. Hazard ratios for

  5. C-reactive Protein: Repeated Measurements will Improve Dialysis Patient Care.

    Science.gov (United States)

    Cobo, Gabriela; Qureshi, Abdul Rashid; Lindholm, Bengt; Stenvinkel, Peter

    2016-01-01

    Systemic inflammation is a common feature in the uremic phenotype and associates with poor outcomes. The awareness regarding the importance of inflammation assessment in chronic kidney disease (CKD) patients has risen in recent years, and despite the development of novel biomarkers, C-reactive protein (CRP) is still the most measured inflammatory parameter. Notwithstanding, the possible weak points of CRP determination, this biomarker has demonstrated being useful both for guidance in clinical practice and for risk estimation. In addition, regular determination of CRP among dialysis patients has been associated with better outcomes in different dialysis facilities. Because persistent inflammation may be a silent reflection of various pathophysiologic alterations in CKD, it is crucial that inflammatory markers are regularly monitored and therapeutic attempts be made to target this inflammation.

  6. Repeated heart rate measurement and cardiovascular outcomes in left ventricular systolic dysfunction.

    Science.gov (United States)

    Hamill, Victoria; Ford, Ian; Fox, Kim; Böhm, Michael; Borer, Jeffrey S; Ferrari, Roberto; Komajda, Michel; Steg, Philippe Gabriel; Tavazzi, Luigi; Tendera, Michal; Swedberg, Karl

    2015-10-01

    Elevated resting heart rate is associated with increased cardiovascular risk, particularly in patients with left ventricular systolic dysfunction. Heart rate is not monitored routinely in these patients. We hypothesized that routine monitoring of heart rate would increase its prognostic value in patients with left ventricular systolic dysfunction. We analyzed the relationship between heart rate measurements and a range of adverse cardiovascular outcomes, including hospitalization for worsening heart failure, in the pooled placebo-treated patients from the morBidity-mortality EvAlUaTion of the If inhibitor ivabradine in patients with coronary disease and left ventricULar dysfunction (BEAUTIFUL) trial and Systolic Heart failure treatment with the If inhibitor ivabradine (SHIFT) Trial, using standard and time-varying covariate Cox proportional hazards models. By adjusting for other prognostic factors, models were fitted for baseline heart rate alone or for time-updated heart rate (latest heart rate) alone or corrected for baseline heart rate or for immediate previous time-updated heart rate. Baseline heart rate was strongly associated with all outcomes apart from hospitalization for myocardial infarction. Time-updated heart rate increased the strengths of associations for all outcomes. Adjustment for baseline heart rate or immediate previous time-updated heart rate modestly reduced the prognostic importance of time-updated heart rate. For hospitalization for worsening heart failure, each 5 beats/min increase in baseline heart rate and time-updated heart rate was associated with a 15% (95% confidence interval, 12-18) and 22% (confidence interval, 19-40) increase in risk, respectively. Even after correction, the prognostic value of time-updated heart rate remained greater. In patients with left ventricular systolic dysfunction, time-updated heart rate is more strongly related with adverse cardiovascular outcomes than baseline heart rate. Heart rate should be measured to

  7. Psychological impact and recovery after involvement in a patient safety incident: a repeated measures analysis

    Science.gov (United States)

    Van Gerven, Eva; Bruyneel, Luk; Panella, Massimiliano; Euwema, Martin; Sermeus, Walter; Vanhaecht, Kris

    2016-01-01

    Objective To examine individual, situational and organisational aspects that influence psychological impact and recovery of a patient safety incident on physicians, nurses and midwives. Design Cross-sectional, retrospective surveys of physicians, midwives and nurses. Setting 33 Belgian hospitals. Participants 913 clinicians (186 physicians, 682 nurses, 45 midwives) involved in a patient safety incident. Main outcome measures The Impact of Event Scale was used to retrospectively measure psychological impact of the safety incident at the time of the event and compare it with psychological impact at the time of the survey. Results Individual, situational as well as organisational aspects influenced psychological impact and recovery of a patient safety incident. Psychological impact is higher when the degree of harm for the patient is more severe, when healthcare professionals feel responsible for the incident and among female healthcare professionals. Impact of degree of harm differed across clinicians. Psychological impact is lower among more optimistic professionals. Overall, impact decreased significantly over time. This effect was more pronounced for women and for those who feel responsible for the incident. The longer ago the incident took place, the stronger impact had decreased. Also, higher psychological impact is related with the use of a more active coping and planning coping strategy, and is unrelated to support seeking coping strategies. Rendered support and a support culture reduce psychological impact, whereas a blame culture increases psychological impact. No associations were found with job experience and resilience of the health professional, the presence of a second victim support team or guideline and working in a learning culture. Conclusions Healthcare organisations should anticipate on providing their staff appropriate and timely support structures that are tailored to the healthcare professional involved in the incident and to the specific

  8. Repeat-until-success quantum repeaters

    Science.gov (United States)

    Bruschi, David Edward; Barlow, Thomas M.; Razavi, Mohsen; Beige, Almut

    2014-09-01

    We propose a repeat-until-success protocol to improve the performance of probabilistic quantum repeaters. Conventionally, these rely on passive static linear-optics elements and photodetectors to perform Bell-state measurements (BSMs) with a maximum success rate of 50%. This is a strong impediment for entanglement swapping between distant quantum memories. Every time a BSM fails, entanglement needs to be redistributed between the corresponding memories in the repeater link. The key ingredients of our scheme are repeatable BSMs. Under ideal conditions, these turn probabilistic quantum repeaters into deterministic ones. Under realistic conditions, our protocol too might fail. However, using additional threshold detectors now allows us to improve the entanglement generation rate by almost orders of magnitude, at a nominal distance of 1000 km, compared to schemes that rely on conventional BSMs. This improvement is sufficient to make the performance of our scheme comparable to the expected performance of some deterministic quantum repeaters.

  9. A novel AX+/BX- paradigm to assess fear learning and safety-signal processing with repeated-measure designs.

    Science.gov (United States)

    Kazama, Andy M; Schauder, Kimberly B; McKinnon, Michael; Bachevalier, Jocelyne; Davis, Michael

    2013-04-15

    One of the core symptoms of anxiety disorders, such as post-traumatic stress disorder, is the failure to overcome feelings of danger despite being in a safe environment. This deficit likely stems from an inability to fully process safety signals, which are cues in the environment that enable healthy individuals to over-ride fear in aversive situations. Studies examining safety signal learning in rodents, humans, and non-human primates currently rely on between-groups designs. Because repeated-measure designs reduce the number of subjects required, and facilitate a broader range of safety signal studies, the current project sought to develop a repeated-measures safety-signal learning paradigm in non-human primates. Twelve healthy rhesus macaques of both sexes received three rounds of auditory fear-potentiated startle training and testing using an AX+/BX- design with all visual cues. Cue AX was paired with an aversive blast of air, whereas the same X cue in compound with another B cue (BX) signaled the absence of an air blast. Hence, cue B served as a safety signal. Once animals consistently discriminated between the aversive (AX+) and safe (BX-) cues, measured by greater startle amplitude in the presence of AX vs. BX, they were tested for conditioned inhibition by eliciting startle in the presence of a novel ambiguous combined cue (AB). Similar to previous AX+/BX- studies, healthy animals rapidly learned to discriminate between the AX+ and BX- cues as well as demonstrate conditioned inhibition in the presence of the combined AB cue (i.e. lower startle amplitude in the presence of AB vs. AX). Additionally, animals performed consistently across three rounds of testing using three new cues each time. The results validate this novel method that will serve as a useful tool for better understanding the mechanisms for the regulation of fear and anxiety. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability

    Directory of Open Access Journals (Sweden)

    Liran Domachevsky

    2017-01-01

    Full Text Available Background. To investigate same day 18F-FDG (Fluorodeoxyglucose PET (Positron Emission Tomography/MR (Magnetic Resonance test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV and lean body mass (SUL in different locations in the liver. Methods. This prospective study was IRB approved with written informed consent obtained. 35 patients (20 women and 15 men, 61±11.2 years that performed a whole-body 18F-FDG PET/MR followed by liver-dedicated contrast-enhanced 18F-FDG PET/MR were included. SUV/L max, mean, and peak were measured inferior to, superior to, and at the right portal vein and in the left lobe of the liver. The coefficient of variation (CV and intraclass correlation coefficient (ICC were calculated and Bland-Altman plots were obtained. Results. The variability for SUV/L’s measurements was lowest inferior to the portal vein (<9.2% followed by measurements performed at the level of the portal vein (<14.6%. Conclusion. The area inferior to the portal vein is the most reliable location for hepatic 18F-FDG uptake measurements on PET/MR.

  11. Magnetic Resonance Spectroscopy in Patients with Insomnia: A Repeated Measurement Study.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Nissen, Christoph; Feige, Bernd; Baglioni, Chiara; Riemann, Dieter; Hennig, Jürgen; Lange, Thomas

    2016-01-01

    Chronic insomnia is one of the most prevalent central nervous system disorders. It is characterized by increased arousal levels, however, the neurobiological causes and correlates of hyperarousal in insomnia remain to be further determined. In the current study, magnetic resonance spectroscopy was used in the morning and evening in a well-characterized sample of 20 primary insomnia patients (12 females; 8 males; 42.7 ± 13.4 years) and 20 healthy good sleepers (12 females; 8 males; 44.1 ± 10.6 years). The most important inhibitory and excitatory neurotransmitters of the central nervous system, γ-aminobutyric acid (GABA) and glutamate/glutamine (Glx), were assessed in the anterior cingulate cortex (ACC) and dorsolateral prefrontal cortex (DLPFC). The primary hypothesis, a diurnal effect on GABA levels in patients with insomnia, could not be confirmed. Moreover, the current results did not support previous findings of altered GABA levels in individuals with insomnia. Exploratory analyses, however, suggested that GABA levels in the ACC may be positively associated with habitual sleep duration, and, thus, reduced GABA levels may be a trait marker of objective sleep disturbances. Moreover, there was a significant GROUP x MEASUREMENT TIME interaction effect on Glx in the DLPFC with increasing Glx levels across the day in the patients but not in the control group. Therefore, Glx levels may reflect hyperarousal at bedtime in those with insomnia. Future confirmatory studies should include larger sample sizes to investigate brain metabolites in different subgroups of insomnia.

  12. Using high-dynamic-range digital repeat photography to measure plant phenology in a subarctic mire.

    Science.gov (United States)

    Garnello, A.; Dye, D. G.; Bogle, R.; Vogel, J.; Saleska, S. R.; Crill, P. M.

    2015-12-01

    A novel Visual Imaging System (VIS) was designed and deployed in a subarctic mire (68° 20' N, 19° 03'E) aimed at cataloging plant biological changes (phenology) and analyzing seasonal color shifts in relation to micrometeorological data along the summer growing season: June-November, 2015. The VIS is designed as a tower-based, solar-powered, automated phenology camera (Phenocam) that collects red, green, blue (RGB) and near-infrared (NIR) landscape images in High Dynamic Range (HDR) with fully programmable temporal resolution. HDR composite images are made through combining a series of rapid-capture photos with incremental increases of exposure times and a fixed focus, minimizing the spatial and visual data lost from shadows or from the over-saturation of light. This visual record of ecosystem phenology stages (Phenophases) is being used to (1) investigate vegetation-dependent spectral indices; (2) establish a cross-year comparison record of Phenophase seasonality; (3) investigate meteorological-dependent vegetation Phenophases; (4) provide ground-truthing measurements that enhance broader spatial-scale remote sensing analyses of subarctic wetlands.

  13. A Finite Mixture of Nonlinear Random Coefficient Models for Continuous Repeated Measures Data.

    Science.gov (United States)

    Kohli, Nidhi; Harring, Jeffrey R; Zopluoglu, Cengiz

    2016-09-01

    Nonlinear random coefficient models (NRCMs) for continuous longitudinal data are often used for examining individual behaviors that display nonlinear patterns of development (or growth) over time in measured variables. As an extension of this model, this study considers the finite mixture of NRCMs that combine features of NRCMs with the idea of finite mixture (or latent class) models. The efficacy of this model is that it allows the integration of intrinsically nonlinear functions where the data come from a mixture of two or more unobserved subpopulations, thus allowing the simultaneous investigation of intra-individual (within-person) variability, inter-individual (between-person) variability, and subpopulation heterogeneity. Effectiveness of this model to work under real data analytic conditions was examined by executing a Monte Carlo simulation study. The simulation study was carried out using an R routine specifically developed for the purpose of this study. The R routine used maximum likelihood with the expectation-maximization algorithm. The design of the study mimicked the output obtained from running a two-class mixture model on task completion data.

  14. FANCM limits meiotic crossovers.

    Science.gov (United States)

    Crismani, Wayne; Girard, Chloé; Froger, Nicole; Pradillo, Mónica; Santos, Juan Luis; Chelysheva, Liudmila; Copenhaver, Gregory P; Horlow, Christine; Mercier, Raphaël

    2012-06-22

    The number of meiotic crossovers (COs) is tightly regulated within a narrow range, despite a large excess of molecular precursors. The factors that limit COs remain largely unknown. Here, using a genetic screen in Arabidopsis thaliana, we identified the highly conserved FANCM helicase, which is required for genome stability in humans and yeasts, as a major factor limiting meiotic CO formation. The fancm mutant has a threefold-increased CO frequency as compared to the wild type. These extra COs arise not from the pathway that accounts for most of the COs in wild type, but from an alternate, normally minor pathway. Thus, FANCM is a key factor imposing an upper limit on the number of meiotic COs, and its manipulation holds much promise for plant breeding.

  15. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  16. Repeatability of corticospinal and spinal measures during lengthening and shortening contractions in the human tibialis anterior muscle.

    Directory of Open Access Journals (Sweden)

    Jamie Tallent

    Full Text Available UNLABELLED: Elements of the human central nervous system (CNS constantly oscillate. In addition, there are also methodological factors and changes in muscle mechanics during dynamic muscle contractions that threaten the stability and consistency of transcranial magnetic stimulation (TMS and perpherial nerve stimulation (PNS measures. PURPOSE: To determine the repeatability of TMS and PNS measures during lengthening and shortening muscle actions in the intact human tibialis anterior. METHODS: On three consecutive days, 20 males performed lengthening and shortening muscle actions at 15, 25, 50 and 80% of maximal voluntary contraction (MVC. The amplitude of the Motor Evoked Potentials (MEPs produced by TMS was measured at rest and during muscle contraction at 90° of ankle joint position. MEPs were normalised to Mmax determined with PNS. The corticospinal silent period was recorded at 80% MVC. Hoffman reflex (H-reflex at 10% isometric and 25% shortening and lengthening MVCs, and V-waves during MVCs were also evoked on each of the three days. RESULTS: With the exception of MEPs evoked at 80% shortening MVC, all TMS-derived measures showed good reliability (ICC = 0.81-0.94 from days 2 to 3. Confidence intervals (CI, 95% were lower between days 2 and 3 when compared to days 1 and 2. MEPs significantly increased at rest from days 1 to 2 (P = 0.016 and days 1 to 3 (P = 0.046. The H-reflex during dynamic muscle contraction was reliable across the three days (ICC = 0.76-0.84. V-waves (shortening, ICC = 0.77, lengthening ICC = 0.54 and the H-reflex at 10% isometric MVC (ICC = 0.66 was generally less reliable over the three days. CONCLUSION: Although it is well known that measures of the intact human CNS exhibit moment-to-moment fluctuations, careful experimental arrangements make it possible to obtain consistent and repeatable measurements of corticospinal and spinal excitability in the actively lengthening and shortening human

  17. Are There Linguistic Markers of Suicidal Writing That Can Predict the Course of Treatment? A Repeated Measures Longitudinal Analysis.

    Science.gov (United States)

    Brancu, Mira; Jobes, David; Wagner, Barry M; Greene, Jeffrey A; Fratto, Timothy A

    2016-07-02

    The purpose of this pilot study was to predict resolution of suicidal ideation and risk over the course of therapy among suicidal outpatients (N = 144) using a novel method for analyzing Self- verses Relationally oriented qualitative written responses to the Suicide Status Form (SSF). A content analysis software program was used to extract word counts and a repeated measures longitudinal design was implemented to assess improvement over time. Patients with primarily Relationally focused word counts were more likely to have a quicker suicide risk resolution than those with more Self-focused word counts (6-7 sessions versus 17-18 sessions). Implications of these data are discussed, including the potential for enhancing treatment outcomes using this method with individuals entering treatment.

  18. A Bayesian model for repeated measures zero-inflated count data with application to outpatient psychiatric service use

    Science.gov (United States)

    Neelon, Brian H.; O’Malley, A. James; Normand, Sharon-Lise T.

    2009-01-01

    In applications involving count data, it is common to encounter an excess number of zeros. In the study of outpatient service utilization, for example, the number of utilization days will take on integer values, with many subjects having no utilization (zero values). Mixed-distribution models, such as the zero-inflated Poisson (ZIP) and zero-inflated negative binomial (ZINB), are often used to fit such data. A more general class of mixture models, called hurdle models, can be used to model zero-deflation as well as zero-inflation. Several authors have proposed frequentist approaches to fitting zero-inflated models for repeated measures. We describe a practical Bayesian approach which incorporates prior information, has optimal small-sample properties, and allows for tractable inference. The approach can be easily implemented using standard Bayesian software. A study of psychiatric outpatient service use illustrates the methods. PMID:21339863

  19. Crossover studies with survival outcomes.

    Science.gov (United States)

    Buyze, Jozefien; Goetghebeur, Els

    2013-12-01

    Crossover designs are well known to have major advantages when comparing the effect of two treatments which do not interact. With a right-censored survival endpoint, however, this design is quickly abandoned in favour of the more costly parallel design. Motivated by human immunodeficiency virus (HIV) prevention studies which lacked power, we evaluate what may be gained in this setting and compare parallel with crossover designs. In a heterogeneous population, we find and explain a substantial increase in power for the crossover study using a non-parametric logrank test. With frailties in a proportional hazards model, crossover designs equally lead to substantially smaller variance for the subject-specific hazard ratio (HR), while the population-averaged HR sees negligible gain. Its efficiency benefit is recovered when the population-averaged HR is reconstructed from estimated subject-specific hazard rates. We derive the time point for treatment crossover that optimizes efficiency and end with the analysis of two recent HIV prevention trials. We find that a Cellulose sulphate trial could have hardly gained efficiency from a crossover design, while a Nonoxynol-9 trial stood to gain substantial power. We conclude that there is a role for effective crossover designs in important classes of survival problems.

  20. Detection of quasi-periodic processes in repeated measurements: New approach for the fitting and clusterization of different data

    Science.gov (United States)

    Nigmatullin, R.; Rakhmatullin, R.

    2014-12-01

    Many experimentalists were accustomed to think that any independent measurement forms a non-correlated measurement that depends weakly from others. We are trying to reconsider this conventional point of view and prove that similar measurements form a strongly-correlated sequence of random functions with memory. In other words, successive measurements "remember" each other at least their nearest neighbors. This observation and justification on real data help to fit the wide set of data based on the Prony's function. The Prony's decomposition follows from the quasi-periodic (QP) properties of the measured functions and includes the Fourier transform as a partial case. New type of decomposition helps to obtain a specific amplitude-frequency response (AFR) of the measured (random) functions analyzed and each random function contains less number of the fitting parameters in comparison with its number of initial data points. Actually, the calculated AFR can be considered as the generalized Prony's spectrum (GPS), which will be extremely useful in cases where the simple model pretending on description of the measured data is absent but vital necessity of their quantitative description is remained. These possibilities open a new way for clusterization of the initial data and new information that is contained in these data gives a chance for their detailed analysis. The electron paramagnetic resonance (EPR) measurements realized for empty resonator (pure noise data) and resonator containing a sample (CeO2 in our case) confirmed the existence of the QP processes in reality. But we think that the detection of the QP processes is a common feature of many repeated measurements and this new property of successive measurements can attract an attention of many experimentalists. To formulate some general conditions that help to identify and then detect the presence of some QP process in the repeated experimental measurements. To find a functional equation and its solution that

  1. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Directory of Open Access Journals (Sweden)

    Po-Shan Wang

    Full Text Available The aim of this study was to correlate magnetic resonance spectroscopy (MRS measurements, including that for the N-acetyl aspartate (NAA/creatine (Cr ratio in the vermis (denoted V-NAA, right cerebellar hemisphere (R-NAA, and left (L-NAA cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA score for patients with spinocerebellar ataxia (SCA types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  2. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Science.gov (United States)

    Wang, Po-Shan; Chen, Hung-Chieh; Wu, Hsiu-Mei; Lirng, Jiing-Feng; Wu, Yu-Te; Soong, Bing-Wen

    2012-01-01

    The aim of this study was to correlate magnetic resonance spectroscopy (MRS) measurements, including that for the N-acetyl aspartate (NAA)/creatine (Cr) ratio in the vermis (denoted V-NAA), right cerebellar hemisphere (R-NAA), and left (L-NAA) cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA) score for patients with spinocerebellar ataxia (SCA) types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score) in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  3. Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, L.; Douglas, N.H.M.; Collins, D.J.; Giles, S.L.; O' Flynn, E.A.M.; Orton, M.; DeSouza, N.M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK and EPSRC Cancer Imaging Centre, Surrey (United Kingdom)

    2014-02-15

    To establish repeatability of apparent diffusion coefficients (ADCs) acquired from free-breathing diffusion-weighted magnetic resonance imaging (DW-MRI) in malignant lung lesions and investigate effects of lesion size, location and respiratory motion. Thirty-six malignant lung lesions (eight patients) were examined twice (1- to 5-h interval) using T1-weighted, T2-weighted and axial single-shot echo-planar DW-MRI (b = 100, 500, 800 s/mm{sup 2}) during free-breathing. Regions of interest around target lesions on computed b = 800 s/mm{sup 2} images by two independent observers yielded ADC values from maps (pixel-by-pixel fitting using all b values and a mono-exponential decay model). Intra- and inter-observer repeatability was assessed per lesion, per patient and by lesion size (> or <2 cm) or location. ADCs were similar between observers (mean ± SD, 1.15 ± 0.28 x 10{sup -3} mm{sup 2}/s, observer 1; 1.15 ± 0.29 x 10{sup -3} mm{sup 2}/s, observer 2). Intra-observer coefficients of variation of the mean [median] ADC per lesion and per patient were 11 % [11.4 %], 5.7 % [5.7 %] for observer 1 and 9.2 % [9.5 %], 3.9 % [4.7 %] for observer 2 respectively; inter-observer values were 8.9 % [9.3 %] (per lesion) and 3.0 % [3.7 %] (per patient). Inter-observer coefficient of variation (CoV) was greater for lesions <2 cm (n = 20) compared with >2 cm (n = 16) (10.8 % vs 6.5 % ADC{sub mean}, 11.3 % vs 6.7 % ADC{sub median}) and for mid (n = 14) vs apical (n = 9) or lower zone (n = 13) lesions (13.9 %, 2.7 %, 3.8 % respectively ADC{sub mean}; 14.2 %, 2.8 %, 4.7 % respectively ADC{sub median}). Free-breathing DW-MRI of whole lung achieves good intra- and inter-observer repeatability of ADC measurements in malignant lung tumours. (orig.)

  4. Pressure and Temperature Sensors Using Two Spin Crossover Materials

    Directory of Open Access Journals (Sweden)

    Catalin-Maricel Jureschi

    2016-02-01

    Full Text Available The possibility of a new design concept for dual spin crossover based sensors for concomitant detection of both temperature and pressure is presented. It is conjectured from numerical results obtained by mean field approximation applied to a Ising-like model that using two different spin crossover compounds containing switching molecules with weak elastic interactions it is possible to simultaneously measure P and T. When the interaction parameters are optimized, the spin transition is gradual and for each spin crossover compounds, both temperature and pressure values being identified from their optical densities. This concept offers great perspectives for smart sensing devices.

  5. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences.

  6. Magnetic crossover effect in Nickel nanowire arrays

    Energy Technology Data Exchange (ETDEWEB)

    Ghaddar, A. [Laboratoire de Magnetisme de Bretagne, CNRS-FRE 3117, C.S. 93837, 29238 Brest, Cedex (France); Gloaguen, F. [Laboratoire de Chimie, Electrochimie Moleculaire et Chimie Analytique, CNRS-UMR 6521, C. S. 93837 Brest Cedex 3 (France); Gieraltowski, J. [Laboratoire de Magnetisme de Bretagne, CNRS-FRE 3117, C.S. 93837, 29238 Brest, Cedex (France); Tannous, C., E-mail: tannous@univ-brest.f [Laboratoire de Magnetisme de Bretagne, CNRS-FRE 3117, C.S. 93837, 29238 Brest, Cedex (France)

    2011-05-01

    A crossover effect in the magnetic reversal mechanism within arrays of Nickel nanowires whose diameter varies from 15 to 100 nm is observed around 50 nm. Hysteresis loops and FMR measurements confirm that nanowire diameter controls effectively the nanowire easy axis as well as the magnetization reversal mechanism. This might be very interesting for spintronic devices based on current-induced domain motion such as non-volatile magnetic memory elements (MRAM) and low Ohmic loss devices.

  7. The use of portable NIRS to measure muscle oxygenation and haemodynamics during a repeated sprint running test.

    Science.gov (United States)

    Jones, Ben; Hesford, Catherine M; Cooper, Chris E

    2013-01-01

    Portable near-infrared spectroscopy (NIRS) devices were originally developed for use in exercise and sports science by Britton Chance in the 1990s (the RunMan and microRunman series). However, only recently with the development of more robust, and wireless systems, has the routine use in elite sport become possible. As with the medical use of NIRS, finding applications of the technology that are relevant to practitioners is the key issue. One option is to use NIRS to track exercise training-induced adaptations in muscle. Portable NIRS devices enable monitoring during the normal 'field' routine uses to assess fitness, such as repeat sprint shuttle tests. Knowledge about the acute physiological responses to these specific tests has practical applications within team sport training prescription, where development of both central and peripheral determinants of high-intensity intermittent exercise needs to be considered. The purpose of this study was to observe NIRS-detected parameters during a repeat sprint test. We used the PortaMon, a two wavelength spatially resolved NIR spectrometer manufactured by Artinis Inc., to assess NIR changes in the gastrocnemius muscle of both the left and right leg during high-intensity running. Six university standard rugby players were assessed (age 20 ± 1.5 years; height 183 ± 1.0 cm; weight 89.4 ± 5.8 kg; body fat 12.2 ± 3.0 %); the subjects completed nine repeated shuttle runs, which incorporated forward, backward and change of direction movements. Individual sprint time, total time to complete test, blood lactate response (BL), heart rate values (HR) and haemoglobin variables (ΔHHb, ΔtHb, ΔHbO2 and ΔTSI%) were measured. Total time to complete the test was 260 ± 20 s, final blood lactate was 14.3 ± 2.8 mM, and maximal HR 182 ± 5 bpm. NIRS variables displayed no differences between right and left legs. During the test, the group-averaged data showed a clear decrease in HbO2 (max. decrease 11.41 ± 4.95 μM), increase in HHb

  8. How integrated are behavioral and endocrine stress response traits? A repeated measures approach to testing the stress-coping style model.

    Science.gov (United States)

    Boulton, Kay; Couto, Elsa; Grimmer, Andrew J; Earley, Ryan L; Canario, Adelino V M; Wilson, Alastair J; Walling, Craig A

    2015-02-01

    It is widely expected that physiological and behavioral stress responses will be integrated within divergent stress-coping styles (SCS) and that these may represent opposite ends of a continuously varying reactive-proactive axis. If such a model is valid, then stress response traits should be repeatable and physiological and behavioral responses should also change in an integrated manner along a major axis of among-individual variation. While there is some evidence of association between endocrine and behavioral stress response traits, few studies incorporate repeated observations of both. To test this model, we use a multivariate, repeated measures approach in a captive-bred population of Xiphophorus birchmanni. We quantify among-individual variation in behavioral stress response to an open field trial (OFT) with simulated predator attack (SPA) and measure waterborne steroid hormone levels (cortisol, 11-ketotestosterone) before and after exposure. Under the mild stress stimulus (OFT), (multivariate) behavioral variation among individuals was consistent with a strong axis of personality (shy-bold) or coping style (reactive-proactive) variation. However, behavioral responses to a moderate stressor (SPA) were less repeatable, and robust statistical support for repeatable endocrine state over the full sampling period was limited to 11-ketotestosterone. Although post hoc analysis suggested cortisol expression was repeatable over short time periods, qualitative relationships between behavior and glucocorticoid levels were counter to our a priori expectations. Thus, while our results clearly show among-individual differences in behavioral and endocrine traits associated with stress response, the correlation structure between these is not consistent with a simple proactive-reactive axis of integrated stress-coping style. Additionally, the low repeatability of cortisol suggests caution is warranted if single observations (or indeed repeat measures over short sampling

  9. SPECIFIC AND CROSS-OVER EFFECTS OF FOAM ROLLING ON ANKLE DORSIFLEXION RANGE OF MOTION

    Science.gov (United States)

    Beardsley, Chris

    2016-01-01

    ABSTRACT Background Flexibility is an important physical quality. Self-myofascial release (SMFR) methods such as foam rolling (FR) increase flexibility acutely but how long such increases in range of motion (ROM) last is unclear. Static stretching (SS) also increases flexibility acutely and produces a cross-over effect to contralateral limbs. FR may also produce a cross-over effect to contralateral limbs but this has not yet been identified. Purpose To explore the potential cross-over effect of SMFR by investigating the effects of a FR treatment on the ipsilateral limb of 3 bouts of 30 seconds on changes in ipsilateral and contralateral ankle DF ROM and to assess the time-course of those effects up to 20 minutes post-treatment. Methods A within- and between-subject design was carried out in a convenience sample of 26 subjects, allocated into FR (n=13) and control (CON, n=13) groups. Ankle DF ROM was recorded at baseline with the in-line weight-bearing lunge test for both ipsilateral and contralateral legs and at 0, 5, 10, 15, 20 minutes following either a two-minute seated rest (CON) or 3 3 30 seconds of FR of the plantar flexors of the dominant leg (FR). Repeated measures ANOVA was used to examine differences in ankle DF ROM. Results No significant between-group effect was seen following the intervention. However, a significant within-group effect (p<0.05) in the FR group was seen between baseline and all post-treatment time-points (0, 5, 10, 15 and 20 minutes). Significant within-group effects (p<0.05) were also seen in the ipsilateral leg between baseline and at all post-treatment time-points, and in the contralateral leg up to 10 minutes post-treatment, indicating the presence of a cross-over effect. Conclusions FR improves ankle DF ROM for at least 20 minutes in the ipsilateral limb and up to 10 minutes in the contralateral limb, indicating that FR produces a cross-over effect into the contralateral limb. The mechanism producing these cross-over effects is

  10. Repeated-sprint cycling does not induce respiratory muscle fatigue in active adults: measurements from the powerbreathe® inspiratory muscle trainer.

    Science.gov (United States)

    Minahan, Clare; Sheehan, Beth; Doutreband, Rachel; Kirkwood, Tom; Reeves, Daniel; Cross, Troy

    2015-03-01

    This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., 'S-Index') before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP) values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p Repeated-sprint cycling had no effect on respiratory muscle strength as measured by the POWERbreathe® (p > 0.99) and during the Mueller maneuver (p > 0.99). The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults. Key pointsThe S-Index as measured by the POWERbreathe® is a reliable measure of respiratory muscle strengthThe S-Index does not accurately reflect maximal inspiratory pressure obtained from a Mueller maneuverRepeated-sprint cycling does not induce respiratory muscle fatigue as measured by the POWERbreathe® and the Manometer.

  11. The spatial regulation of meiotic recombination hotspots: are all DSB hotspots crossover hotspots?

    Science.gov (United States)

    Serrentino, Maria-Elisabetta; Borde, Valérie

    2012-07-15

    A key step for the success of meiosis is programmed homologous recombination, during which crossovers, or exchange of chromosome arms, take place. Crossovers increase genetic diversity but their main function is to ensure accurate chromosome segregation. Defects in crossover number and position produce aneuploidies that represent the main cause of miscarriages and chromosomal abnormalities such as Down's syndrome. Recombination is initiated by the formation of programmed double strand breaks (DSBs), which occur preferentially at places called DSB hotspots. Among all DSBs generated, only a small fraction is repaired by crossover, the other being repaired by other homologous recombination pathways. Crossover maps have been generated in a number of organisms, defining crossover hotspots. With the availability of genome-wide maps of DSBs as well as the ability to measure genetically the repair outcome at several hotspots, it is becoming more and more clear that not all DSB hotspots behave the same for crossover formation, suggesting that chromosomal features distinguish different types of hotspots.

  12. Ambient particulate air pollution and circulating antioxidant enzymes: A repeated-measure study in healthy adults in Beijing, China.

    Science.gov (United States)

    Wu, Shaowei; Wang, Bin; Yang, Di; Wei, Hongying; Li, Hongyu; Pan, Lu; Huang, Jing; Wang, Xin; Qin, Yu; Zheng, Chanjuan; Shima, Masayuki; Deng, Furong; Guo, Xinbiao

    2016-01-01

    The association of systemic antioxidant activity with ambient air pollution has been unclear. A panel of 40 healthy college students underwent repeated blood collection for 12 occasions under three exposure scenarios before and after relocating from a suburban area to an urban area in Beijing, China in 2010-2011. We measured various air pollutants including fine particles (PM2.5) and determined circulating levels of antioxidant enzymes extracellular superoxide dismutase (EC-SOD) and glutathione peroxidase 1 (GPX1) in the laboratory. An interquartile range increase of 63.4 μg/m(3) at 3-d PM2.5 moving average was associated with a 6.3% (95% CI: 0.6, 12.4) increase in EC-SOD and a 5.5% (95% CI: 1.3, 9.8) increase in GPX1. Several PM2.5 chemical constituents, including negative ions (nitrate and chloride) and metals (e.g., iron and strontium), were consistently associated with increases in EC-SOD and GPX1. Our results support activation of circulating antioxidant enzymes following exposure to particulate air pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A method to construct a points system to predict cardiovascular disease considering repeated measures of risk factors

    Science.gov (United States)

    Carbayo-Herencia, Julio Antonio; Vigo, Maria Isabel; Gil-Guillén, Vicente Francisco

    2016-01-01

    Current predictive models for cardiovascular disease based on points systems use the baseline situation of the risk factors as independent variables. These models do not take into account the variability of the risk factors over time. Predictive models for other types of disease also exist that do consider the temporal variability of a single biological marker in addition to the baseline variables. However, due to their complexity these other models are not used in daily clinical practice. Bearing in mind the clinical relevance of these issues and that cardiovascular diseases are the leading cause of death worldwide we show the properties and viability of a new methodological alternative for constructing cardiovascular risk scores to make predictions of cardiovascular disease with repeated measures of the risk factors and retaining the simplicity of the points systems so often used in clinical practice (construction, statistical validation by simulation and explanation of potential utilization). We have also applied the system clinically upon a set of simulated data solely to help readers understand the procedure constructed. PMID:26893963

  14. Are diagnostic criteria for acute malnutrition affected by hydration status in hospitalized children? A repeated measures study

    Directory of Open Access Journals (Sweden)

    Fegan Gregory

    2011-09-01

    Full Text Available Abstract Introduction Dehydration and malnutrition commonly occur together among ill children in developing countries. Dehydration (change in total body water is known to alter weight. Although muscle tissue has high water content, it is not known whether mid-upper arm circumference (MUAC may be altered by changes in tissue hydration. We aimed to determine whether rehydration alters MUAC, MUAC Z score (MUACz, weight-for-length Z-score (WFLz and classification of nutritional status among hospitalised Kenyan children admitted with signs of dehydration. Study procedure We enrolled children aged from 3 months to 5 years admitted to a rural Kenyan district hospital with clinical signs compatible with dehydration, and without kwashiorkor. Anthropometric measurements were taken at admission and repeated after 48 hours of treatment, which included rehydration by WHO protocols. Changes in weight observed during this period were considered to be due to changes in hydration status. Results Among 325 children (median age 11 months the median weight gain (rehydration after 48 hours was 0.21 kg, (an increase of 2.9% of admission body weight. Each 1% change in weight was associated with a 0.40 mm (95% CI: 0.30 to 0.44 mm, p Conclusion MUAC is less affected by dehydration than WFLz and is therefore more suitable for nutritional assessment of ill children. However, both WFLz and MUAC misclassify SAM among dehydrated children. Nutritional status should be re-evaluated following rehydration, and management adjusted accordingly.

  15. Selecting a linear mixed model for longitudinal data: repeated measures analysis of variance, covariance pattern model, and growth curve approaches.

    Science.gov (United States)

    Liu, Siwei; Rovine, Michael J; Molenaar, Peter C M

    2012-03-01

    With increasing popularity, growth curve modeling is more and more often considered as the 1st choice for analyzing longitudinal data. Although the growth curve approach is often a good choice, other modeling strategies may more directly answer questions of interest. It is common to see researchers fit growth curve models without considering alterative modeling strategies. In this article we compare 3 approaches for analyzing longitudinal data: repeated measures analysis of variance, covariance pattern models, and growth curve models. As all are members of the general linear mixed model family, they represent somewhat different assumptions about the way individuals change. These assumptions result in different patterns of covariation among the residuals around the fixed effects. In this article, we first indicate the kinds of data that are appropriately modeled by each and use real data examples to demonstrate possible problems associated with the blanket selection of the growth curve model. We then present a simulation that indicates the utility of Akaike information criterion and Bayesian information criterion in the selection of a proper residual covariance structure. The results cast doubt on the popular practice of automatically using growth curve modeling for longitudinal data without comparing the fit of different models. Finally, we provide some practical advice for assessing mean changes in the presence of correlated data.

  16. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  17. Repeated measurements of blood lactate concentration as a prognostic marker in horses with acute colitis evaluated with classification and regression trees (CART) and random forest analysis.

    Science.gov (United States)

    Petersen, M B; Tolver, A; Husted, L; Tølbøll, T H; Pihl, T H

    2016-07-01

    The objective of this study was to investigate the prognostic value of single and repeated measurements of blood l-lactate (Lac) and ionised calcium (iCa) concentrations, packed cell volume (PCV) and plasma total protein (TP) concentration in horses with acute colitis. A total of 66 adult horses admitted with acute colitis (2 mmol/L (sensitivity, 0.72; specificity, 0.8). In conclusion, blood lactate concentration measured at admission and repeated 6 h later aided the prognostic evaluation of horses with acute colitis in this population with a very high mortality rate. This should allow clinicians to give a more reliable prognosis for the horse.

  18. Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experience.

    Science.gov (United States)

    Patel, Neil; Dodsworth, Melissa; Mills, John F

    2011-05-01

    To assess (1) agreement between the ultrasonic cardiac output monitor (USCOM) 1A device for measurement of cardiac output in newborn infants and conventional echocardiography (ECHO), (2) repeatability of USCOM measurements and (3) agreement between novice and expert users of the USCOM. A prospective observational study. The Neonatal Unit at the Royal Children's Hospital, Melbourne, Australia. 56 term and near-term infants, with no evidence of structural or functional cardiovascular disease, or haemodynamic shunts. Agreement between ECHO and USCOM was assessed by paired measurements of ventricular outputs by a single experienced user. Repeatability was assessed using five repeated measurements in 10 infants. Agreement between five novices and one expert user was assessed by paired USCOM measurements over 30 training measurements. Agreement between USCOM and ECHO for left ventricular output (LVO) was (bias, ±limits of agreement, mean % error): 14, ±108 ml/kg/min, 43%, and for right ventricular output (RVO): -59, ±160, ml/kg/min, 57%. Intra-observer repeatability was 6.7% for USCOM LVO and 3.6% for ECHO LVO. After five training measurements, the mean difference between USCOM measures of LVO by novice and expert users was less than 50 ml/kg/min, but with variability. Repeatability of USCOM measures is high in newborn infants. New users can be trained quickly, but with high inter-user variability. Agreement between USCOM and conventional ECHO is broad, and worse for RVO and LVO. Further studies are required to assess the ability of the device to detect clinically significant changes in infant cardiac output.

  19. Effects of CAG repeat length, HTT protein length and protein context on cerebral metabolism measured using magnetic resonance spectroscopy in transgenic mouse models of Huntington's disease.

    Science.gov (United States)

    Jenkins, Bruce G; Andreassen, Ole A; Dedeoglu, Alpaslan; Leavitt, Blair; Hayden, Michael; Borchelt, David; Ross, Christopher A; Ferrante, Robert J; Beal, M Flint

    2005-10-01

    Huntington's disease is a neurodegenerative illness caused by expansion of CAG repeats at the N-terminal end of the protein huntingtin. We examined longitudinal changes in brain metabolite levels using in vivo magnetic resonance spectroscopy in five different mouse models. There was a large (>50%) exponential decrease in N-acetyl aspartate (NAA) with time in both striatum and cortex in mice with 150 CAG repeats (R6/2 strain). There was a linear decrease restricted to striatum in N171-82Q mice with 82 CAG repeats. Both the exponential and linear decreases of NAA were paralleled in time by decreases in neuronal area measured histologically. Yeast artificial chromosome transgenic mice with 72 CAG repeats, but low expression levels, had less striatal NAA loss than the N171-82Q mice (15% vs. 43%). We evaluated the effect of gene context in mice with an approximate 146 CAG repeat on the hypoxanthine phosphoribosyltransferase gene (HPRT). HPRT mice developed an obese phenotype in contrast to weight loss in the R6/2 and N171-82Q mice. These mice showed a small striatal NAA loss (21%), and a possible increase in brain lipids detectable by magnetic resonance (MR) spectroscopy and decreased brain water T1. Our results indicate profound metabolic defects that are strongly affected by CAG repeat length, as well as gene expression levels and protein context.

  20. Detecting variable responses in time-series using repeated measures ANOVA: Application to physiologic challenges [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Paul M. Macey

    2016-07-01

    Full Text Available We present an approach to analyzing physiologic timetrends recorded during a stimulus by comparing means at each time point using repeated measures analysis of variance (RMANOVA. The approach allows temporal patterns to be examined without an a priori model of expected timing or pattern of response. The approach was originally applied to signals recorded from functional magnetic resonance imaging (fMRI volumes-of-interest (VOI during a physiologic challenge, but we have used the same technique to analyze continuous recordings of other physiological signals such as heart rate, breathing rate, and pulse oximetry. For fMRI, the method serves as a complement to whole-brain voxel-based analyses, and is useful for detecting complex responses within pre-determined brain regions, or as a post-hoc analysis of regions of interest identified by whole-brain assessments. We illustrate an implementation of the technique in the statistical software packages R and SAS. VOI timetrends are extracted from conventionally preprocessed fMRI images. A timetrend of average signal intensity across the VOI during the scanning period is calculated for each subject. The values are scaled relative to baseline periods, and time points are binned. In SAS, the procedure PROC MIXED implements the RMANOVA in a single step. In R, we present one option for implementing RMANOVA with the mixed model function “lme”. Model diagnostics, and predicted means and differences are best performed with additional libraries and commands in R; we present one example. The ensuing results allow determination of significant overall effects, and time-point specific within- and between-group responses relative to baseline. We illustrate the technique using fMRI data from two groups of subjects who underwent a respiratory challenge. RMANOVA allows insight into the timing of responses and response differences between groups, and so is suited to physiologic testing paradigms eliciting complex

  1. The Effects of Group Leader Learning Style on Student Knowledge Gain in a Leadership Camp Setting: A Repeated-Measures Experiment

    Science.gov (United States)

    Brown, Nicholas R.; Terry, Robert, Jr.

    2013-01-01

    Many state FFA associations conduct summer camps focusing on leadership and personal development for FFA members. Interestingly, little research has been conducted on the impact or outcomes of these common activities. The purpose of this split-plot factorial repeated-measures experiment was to assess the level of campers' learning of the…

  2. Power and sample size for the S:T repeated measures design combined with a linear mixed-effects model allowing for missing data.

    Science.gov (United States)

    Tango, Toshiro

    2017-02-13

    Tango (Biostatistics 2016) proposed a new repeated measures design called the S:T repeated measures design, combined with generalized linear mixed-effects models and sample size calculations for a test of the average treatment effect that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size compared with the simple pre-post design. In this article, we present formulas for calculating power and sample sizes for a test of the average treatment effect allowing for missing data within the framework of the S:T repeated measures design with a continuous response variable combined with a linear mixed-effects model. Examples are provided to illustrate the use of these formulas.

  3. Predictors and Variability of Repeat Measurements of Urinary Phenols and Parabens in a Cohort of Shanghai Women and Men

    Science.gov (United States)

    Buckley, Jessie P.; Yang, Gong; Liao, Linda M.; Satagopan, Jaya; Calafat, Antonia M.; Matthews, Charles E.; Cai, Qiuyin; Ji, Bu-Tian; Cai, Hui; Wolff, Mary S.; Rothman, Nathaniel; Zheng, Wei; Xiang, Yong-Bing; Shu, Xiao-Ou; Gao, Yu-Tang; Chow, Wong-Ho

    2014-01-01

    , under certain circumstances, among women. Citation: Engel LS, Buckley JP, Yang G, Liao LM, Satagopan J, Calafat AM, Matthews CE, Cai Q, Ji BT, Cai H, Engel SM, Wolff MS, Rothman N, Zheng W, Xiang YB, Shu XO, Gao YT, Chow WH. 2014. Predictors and variability of repeat measurements of urinary phenols and parabens in a cohort of Shanghai women and men. Environ Health Perspect 122:733–740; http://dx.doi.org/10.1289/ehp.1306830 PMID:24659570

  4. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures

    Directory of Open Access Journals (Sweden)

    Karahalios Amalia

    2012-07-01

    Full Text Available Abstract Background Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007; Vandenbroucke et al. (PLoS Med, 4:e297, 2007 and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009 recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. Methods A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Results Among the 82 papers meeting the inclusion criteria, only 35 (43% reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83% described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n = 54, 66%. Other papers used more sophisticated methods including multiple imputation (n = 5 or fully Bayesian modeling (n = 1. Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n = 7, the missing indicator method (n = 1, and mean value substitution (n = 3. For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. Conclusions This review highlights the inconsistent reporting of missing data in cohort studies and the continuing

  5. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures.

    Science.gov (United States)

    Karahalios, Amalia; Baglietto, Laura; Carlin, John B; English, Dallas R; Simpson, Julie A

    2012-07-11

    Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007); Vandenbroucke et al. (PLoS Med, 4:e297, 2007) and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009) recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Among the 82 papers meeting the inclusion criteria, only 35 (43%) reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83%) described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n=54, 66%). Other papers used more sophisticated methods including multiple imputation (n=5) or fully Bayesian modeling (n=1). Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n=7), the missing indicator method (n=1), and mean value substitution (n=3). For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. This review highlights the inconsistent reporting of missing data in cohort studies and the continuing use of inappropriate methods to handle missing data in the analysis. Epidemiological journals

  6. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    ABSTRACT: BACKGROUND: Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...... questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants "recovered" at a specific time point? This question was answered using logistic regression analysis. 3: What is the time...

  7. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction and...

  8. Heart rate variability and DNA methylation levels are altered after short-term metal fume exposure among occupational welders: a repeated-measures panel study

    OpenAIRE

    2014-01-01

    Background: In occupational settings, boilermakers are exposed to high levels of metallic fine particulate matter (PM2.5) generated during the welding process. The effect of welding PM2.5 on heart rate variability (HRV) has been described, but the relationship between PM2.5, DNA methylation, and HRV is not known. Methods: In this repeated-measures panel study, we recorded resting HRV and measured DNA methylation levels in transposable elements Alu and long interspersed nuclear element-1 (LINE...

  9. Repeated measures dose-finding design with time-trend detection in the presence of correlated toxicity data.

    Science.gov (United States)

    Yin, Jun; Paoletti, Xavier; Sargent, Daniel J; Mandrekar, Sumithra J

    2017-08-01

    Phase I trials are designed to determine the safety, tolerability, and recommended phase 2 dose of therapeutic agents for subsequent testing. The dose-finding paradigm has thus traditionally focused on identifying the maximum tolerable dose of an agent or combination therapy under the assumption that there is a non-decreasing relationship between dose-toxicity and dose-efficacy. The dose is typically determined based on the probability of severe toxicity observed during the first treatment cycle. A novel endpoint, the total toxicity profile, was previously developed to account for the multiple toxicity types and grades experienced in the first cycle. More recently, this was extended to a repeated measures design based on the total toxicity profile to account for longitudinal toxicities over multiple treatment cycles in the absence of within-patient correlation. In this work, we propose to extend the design in the presence of within-patient correlation. Furthermore, we provide a framework to detect a toxicity time trend (toxicity increasing, decreasing, or stable) over multiple treatment cycles. We utilize a linear mixed model in the Bayesian framework, with the addition of Bayesian risk functions for decision-making in dose assignment. The performance of this design was evaluated using simulation studies and real data from a phase I trial. We demonstrated that using available toxicity data from all cycles of treatment improves the accuracy of maximum tolerated dose identification and allows for the detection of a time trend. The performance is consistent regardless of the strength of the within-patient correlation. In addition, the use of a quasi-continuous total toxicity profile score significantly increased the power to detect time trends compared to when binary data only were used. The increased interest in molecularly targeted agents and immunotherapies in oncology necessitates innovative phase I study designs. Our proposed framework provides a tool to tackle

  10. Modified Order Crossover (OX Operator

    Directory of Open Access Journals (Sweden)

    Ms. Monica Sehrawat,

    2011-05-01

    Full Text Available In this work Traveling salesperson problem is taken as Domain. TSP has long been known to be NP-complete and is a standard example of such problems. Genetic Algorithm (GA is an approximate algorithmthat doesn’t always aim to find the shortest tour but to find a reasonably short tour quickly, which is a search procedure inspired by the mechanisms of biological evolution. In genetic algorithms, crossovers are used as a main search operator for TSP. Briefly speaking: the role of crossovers is to generate offspring that are better tours by preserving partial tours from the parents. There were a lot attempts to discover an appropriate crossover operator. This paper presents the strategy which used to find the nearly optimized solution to these type of problems. It is the order crossover operator (OX which was proposed by Davis, which constructs an offspring by choosing a subsequence of one parent and preserving the relative order of cities of the other parent.

  11. Young investigator challenge: Atypia of undetermined significance in thyroid FNA: Standardized terminology without standardized management--a closer look at repeat FNA and quality measures.

    Science.gov (United States)

    Brandler, Tamar C; Aziz, Mohamed S; Coutsouvelis, Constantinos; Rosen, Lisa; Rafael, Oana C; Souza, Fabiola; Jelloul, Fatima-Zahra; Klein, Melissa A

    2016-01-01

    The Bethesda system (TBS) for the reporting of thyroid cytopathology established the category of atypia of undetermined significance (AUS) with a 7% target rate and a 5% to 15% implied malignancy risk. Recent literature has reported a broad range of AUS rates, subsequent malignancy rates, and discrepant results from repeat fine-needle aspiration (FNA) versus surgical follow-up. Therefore, this study examined AUS data from the Hofstra North Shore-LIJ School of Medicine to determine the best clinical follow-up. Thyroid aspirates interpreted as AUS in 2012-2014 at the Hofstra North Shore-LIJ School of Medicine were collected. Repeat FNA and surgical follow-up data were tabulated to establish AUS, secondary AUS (diagnosed upon repeat FNA follow-up of a primary FNA AUS diagnosis), atypia of undetermined significance/malignancy (AUS:M) ratios (according to the TBS categories), and malignancy rates for AUS. The AUS rate was 8.5% (976/11,481), and there was follow-up data for 545 cases. The AUS:M ratio was 2.0. Repeat FNA was performed for 281 cases; 57 proceeded to surgical intervention. Repeat FNA reclassified 71.17% of the cases. The malignancy rates for AUS cases proceeding directly to surgery and for those receiving a surgical intervention after a repeat AUS diagnosis were 33.33% and 43.75%, respectively. Repeat FNA resulted in definitive diagnostic reclassification for 67.61% of primary AUS cases and reduced the number of patients triaged to surgery, with 56.58% of the cases recategorized as benign. Cases undergoing surgery after repeat AUS had a higher malignancy rate than those going straight to surgery, and this emphasizes the value of repeat FNA in selecting surgical candidates. In addition, this study highlights the utility of AUS rate monitoring as a quality measure that has contributed to the ability of the Hofstra North Shore-LIJ School of Medicine to adhere closely to TBS recommendations. © 2016 American Cancer Society.

  12. The effects of repeated-sprint training on field-based fitness measures: a meta-analysis of controlled and non-controlled trials.

    Science.gov (United States)

    Taylor, Jonathan; Macpherson, Tom; Spears, Iain; Weston, Matthew

    2015-06-01

    Repeated-sprint training appears to be an efficient and practical means for the simultaneous development of different components of fitness relevant to team sports. Our objective was to systematically review the literature and meta-analyse the effect of repeated-sprint training on a selection of field-based measures of athletic performance, i.e. counter-movement jump, 10 m sprint, 20 m sprint, 30 m sprint, repeated-sprint ability and high-intensity intermittent running performance. The SPORTDiscus, PubMed, MEDLINE and Web of Science databases were searched for original research articles. Search terms included 'repeated-sprint training', 'sprint training', 'aerobic endurance', 'repeated-sprint ability', 'counter-movement jump' and 'sprint performance'. Inclusion criteria included intervention consisting of a series of ≤10 s sprints with ≤60 s recovery; trained participants; intervention duration of 2-12 weeks; field-based fitness measures; running- or cycling-based intervention; published up to, and including, February 2014. Our final dataset included six trials for counter-movement jump (two controlled trials), eight trials for 10 m sprint, four trials for 20 m sprint (three controlled trials), two trials for 30 m sprint, eight trials for repeated-sprint ability and three trials for high-intensity intermittent running performance. Analyses were conducted using comprehensive meta-analysis software. Uncertainty in the meta-analysed effect of repeated-sprint training was expressed as 95% confidence limits (CL), along with the probability that the true value of the effect was trivial, beneficial or harmful. Magnitude-based inferences were based on standardised thresholds for small, moderate and large changes of 0.2, 0.6 and 1.2 standard deviations, respectively. Repeated-sprint training had a likely small beneficial effect in non-controlled counter-movement jump trials (effect size 0.33; 95% CL ±0.30), with a possibly moderate beneficial effect in controlled

  13. Effects of repeatability measures on results of fMRI sICA: a study on simulated and real resting-state effects.

    Science.gov (United States)

    Remes, Jukka J; Starck, Tuomo; Nikkinen, Juha; Ollila, Esa; Beckmann, Christian F; Tervonen, Osmo; Kiviniemi, Vesa; Silven, Olli

    2011-05-15

    Spatial independent components analysis (sICA) has become a widely applied data-driven method for fMRI data, especially for resting-state studies. These sICA approaches are often based on iterative estimation algorithms and there are concerns about accuracy due to noise. Repeatability measures such as ICASSO, RAICAR and ARABICA have been introduced as remedies but information on their effects on estimates is limited. The contribution of this study was to provide more of such information and test if the repeatability analyses are necessary. We compared FastICA-based ordinary and repeatability approaches concerning mixing vector estimates. Comparisons included original FastICA, FSL4 Melodic FastICA and original and modified ICASSO. The effects of bootstrapping and convergence threshold were evaluated. The results show that there is only moderate improvement due to repeatability measures and only in the bootstrapping case. Bootstrapping attenuated power from time courses of resting-state network related ICs at frequencies higher than 0.1 Hz and made subsets of low frequency oscillations more emphasized IC-wise. The convergence threshold did not have a significant role concerning the accuracy of estimates. The performance results suggest that repeatability measures or strict converge criteria might not be needed in sICA analyses of fMRI data. Consequently, the results in existing sICA fMRI literature are probably valid in this sense. A decreased accuracy of original bootstrapping ICASSO was observed and corrected by using centrotype mixing estimates but the results warrant for thorough evaluations of data-driven methods in general. Also, given the fMRI-specific considerations, further development of sICA methods is strongly encouraged. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. The Effect of Nitrogen Cross-Over on Water Balance Measurements in Proton Exchange Membrane Fuel Cell Using Constant Temperature Anemometry

    DEFF Research Database (Denmark)

    Al Shakhshir, Saher; Berning, Torsten; Kær, Søren Knudsen

    2016-01-01

    by introducing 1% of nitrogen concentration to the dry and humidified hydrogen flow simulating the PEMFC anode outlet. The hot wire voltage is measured with and without nitrogen and it was slightly lower with the presence of nitrogen. The effect of the voltage reduction on the measured water balance is small....... This is due to the effect of 1% nitrogen on power law constant’s “m” which can be used in determining the water balance as explained in previous work was extremely low. Thus, the hot wire technique for measuring the PEMFC water balance is still accurate with the nitrogen cross-over......A novel method to obtain an ad-hoc and real time electrical signal of the PEMFC water balance by employing a constant temperature hot wire anemometry has been developed by our fuel cell research group. In this work, the effect of nitrogen-cross over on this method is experimentally demonstrated...

  15. Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses.

    Science.gov (United States)

    Convertino, Victor A; Ratliff, Duane A; Doerr, Donald F; Ludwig, David A; Muniz, Gary W; Benedetti, Erik; Chavarria, Jose; Koreen, Susan; Nguyen, Claude; Wang, Jeff

    2003-03-01

    We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.

  16. Crossover Interference on Nucleolus Organizing Region-Bearing Chromosomes in Arabidopsis

    Science.gov (United States)

    Lam, Sandy Y.; Horn, Sarah R.; Radford, Sarah J.; Housworth, Elizabeth A.; Stahl, Franklin W.; Copenhaver, Gregory P.

    2005-01-01

    In most eukaryotes, crossovers are not independently distributed along the length of a chromosome. Instead, they appear to avoid close proximity to one another—a phenomenon known as crossover interference. Previously, for three of the five Arabidopsis chromosomes, we measured the strength of interference and suggested a model wherein some crossovers experience interference while others do not. Here we show, using the same model, that the fraction of interference-insensitive crossovers is significantly smaller on the remaining two chromosomes. Since these two chromosomes bear the Arabidopsis NOR domains, the possibility that these chromosomal regions influence interference is discussed. PMID:15802520

  17. Observation of the crossover from two-gap to single-gap superconductivity through specific heat measurements in neutron-irradiated MgB2.

    Science.gov (United States)

    Putti, M; Affronte, M; Ferdeghini, C; Manfrinetti, P; Tarantini, C; Lehmann, E

    2006-02-24

    We report specific heat measurements on neutron-irradiated MgB2 samples, for which the critical temperature is lowered to 8.7 K, but the superconducting transition remains extremely sharp, indicative of a defect structure extremely homogeneous. Our results evidence the presence of two superconducting gaps in the temperature range above 21 K, while single-gap superconductivity is well established as a bulk property, not associated with local disorder fluctuations, when Tc decreases to 11 K.

  18. Evaluation of Tip Surface Collision Count as a Measure of Fibreoptic Scope Handling Skills: A Randomized, Cross-Over Manikin Study

    Directory of Open Access Journals (Sweden)

    Mari H. Roberts

    2014-01-01

    Full Text Available Background. In this pilot study, we evaluated tip collisions against three commonly used measures of fibreoptic scope handling skills. Methods. Seventy-seven anaesthetists were recruited to perform a standardized task on an Oxford Box and a modified AirSim manikin. Collision count was correlated against time to scope placement, a global rating scale score, and up-to-date fibreoptic experience. Results. Strong and moderate correlations were found between collision count and task completion time for the Oxford Box (ρ = 0.730, P < 0.0001 and AirSim manikin (ρ = 0.405, P < 0.0001, respectively. Moderate correlation was found between collision count and global rating scale score for the Oxford Box (ρ = −0.545, P < 0.0001 and AirSim manikin (ρ = −0.500, P < 0.0001. Mild and moderate correlations were found between collision count and fibreoptic experience on the Oxford Box (ρ = −0.240, P = 0.041 and AirSim manikin (ρ = −0.423, P < 0.0001, respectively. Conclusions. This study infers that collision count may be used as a measure of fibreoptic scope handling skills in simulation training. Using this outcome in addition to other measures of performance may improve accuracy and precision of fibreoptic scope placement.

  19. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    controlled to great precision, but in a Cubesat , there may be no attitude determination at all. Such a Cubesat might treat sun angle and tumbling rates as...could be sensitive to small differences in motor controller timing. In these cases, the analyst might choose to model the entire deployment path, with...knowledge of the material damage model or motor controller timing precision. On the other hand, if many repeated and environmentally representative

  20. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  1. The antiplaque efficacy of propolis-based herbal toothpaste: A crossover clinical study

    Science.gov (United States)

    Bhat, Nagesh; Bapat, Salil; Asawa, Kailash; Tak, Mridula; Chaturvedi, Pulkit; Gupta, Vivek V.; George, Pradeep P.

    2015-01-01

    Background: In recent years, herbal products have been suggested as an economic, safe and probably effective alternative for prevention and control of various oral diseases. But still there are some products which need to be evaluated. Of lately, Propolis is one such product. To assess and compare the efficacy of herbal dentifrice containing Propolis with Miswak and Colgate total toothpastes in controlling plaque formation. Materials and Methods: A double blind, randomized, crossover study design was conducted among thirty healthy dental students. After oral prophylaxis all subjects were given a washout product for one week period. Subjects were then made to brush with (washout product) for 1 minute followed by 1 minute brushing with assigned test product. The baseline MGMPI plaque scores were recorded. Subjects were then refrained from oral hygiene for 24 hours, and were recalled to be re-disclosed and re-measured for plaque formation. This procedure was repeated according to crossover design after a washout period of (2 week). Statistical tests used were Krukalwallis and Wilcoxon sign rank test. Results: There was a significant difference in 24 hour score between the test products evaluated. When the change from baseline to 24 hours was analyzed, the test product Propolis resulted in a consistently and significantly (p < 0.05) lower MGMPI mean scores than the Colgate Total and Miswak toothpastes. Conclusion: Propolis was found to be safe and effective in reducing plaque accumulation when compared to Miswak and Colgate total toothpaste. PMID:26283831

  2. Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Edwin Hong-Teck Loh

    2017-08-01

    Full Text Available BackgroundWith increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients.MethodsThis is a retrospective cohort study. Patients with Alzheimer’s disease (AD or mild cognitive impairment (MCI with no change in global clinical dementia rating (CDR score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL and retinal nerve fiber layer (RNFL parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC and coefficients of variation (CoVs.ResultsWe included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948–0.985, and CoV was 1.81% (range: 1.14–2.40; while the average inter-visit ICC was 0.968 (0.941–0.985, and CoV was 1.91% (range: 1.24–2.32. The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937–0.986 and 2.32% (range: 1.34–2.90%, respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845–0.961 and 3.83% (range: 2.71–5.25%, respectively.ConclusionBoth GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time.

  3. Fractal-to-nonfractal crossover for viscous fingers

    Science.gov (United States)

    Lee, Jysoo; Coniglio, Antonio; Stanley, H. Eugene

    1990-04-01

    We propose a position-space renormalization-group approach to the problem of viscous fingering in the absence of surface tension, with arbitrary viscosity ratio between the injected and displaced fluid. We find there are only two fixed points, the Eden and the diffusion-limited aggregation (DLA) points. The Eden point, which corresponds to a compact cluster with nonfractal surface, is stable in all directions, while the DLA fixed point is a saddle point. Hence if the viscosity of the injected fluid is not zero, the system must eventually cross over to a compact cluster. We also calculate the crossover exponent φ and crossover radius R×, and discuss possible experimental measurements.

  4. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Mirian Ara

    2015-01-01

    Full Text Available Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL thickness parameters measured by scanning laser polarimetry (SLP with enhanced corneal compensation (ECC in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC, coefficient of variation (COV, and test-retest variability (TRT were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT average was the highest (0.967 and 0.946 in normal eyes, while nerve fiber indicator (NFI; 0.982 and inferior average (0.978 yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43% in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  5. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  6. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T1-weighted images (3D-T1WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  7. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  8. Crossover Designs in Nutrition and Dietetics Research.

    Science.gov (United States)

    Harris, Jeffrey E; Raynor, Hollie A

    2017-07-01

    This article is the 12th installment in a statistical series exploring the importance of research design, epidemiologic methods, and statistical analysis as applied to nutrition and dietetics research. The purpose of this series is to assist registered dietitian nutritionists in interpreting nutrition research and aid nutrition researchers in applying scientific principles to produce high-quality nutrition research. This article focuses on the use of crossover designs in nutrition and dietetics research. The purpose is to distinguish the crossover design from the randomized clinical trial, define important terms, illustrate a 2×2 crossover design, discuss potential confounding variables in the crossover design, describe the analysis and interpretation of crossover data, present sample size considerations, provide examples of the use of the crossover design in nutrition and dietetics, and discuss additional considerations when the independent variable has more than two levels. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  9. An Analysis of Semantic Aware Crossover

    Science.gov (United States)

    Uy, Nguyen Quang; Hoai, Nguyen Xuan; O'Neill, Michael; McKay, Bob; Galván-López, Edgar

    It is well-known that the crossover operator plays an important role in Genetic Programming (GP). In Standard Crossover (SC), semantics are not used to guide the selection of the crossover points, which are generated randomly. This lack of semantic information is the main cause of destructive effects from SC (e.g., children having lower fitness than their parents). Recently, we proposed a new semantic based crossover known GP called Semantic Aware Crossover (SAC) [25]. We show that SAC outperforms SC in solving a class of real-value symbolic regression problems. We clarify the effect of SAC on GP search in increasing the semantic diversity of the population, thus helping to reduce the destructive effects of crossover in GP.

  10. Repeated-Sprint Cycling Does Not Induce Respiratory Muscle Fatigue in Active Adults: Measurements from The Powerbreathe® Inspiratory Muscle Trainer

    Directory of Open Access Journals (Sweden)

    Clare Minahan, Beth Sheehan, Rachel Doutreband, Tom Kirkwood, Daniel Reeves, Troy Cross

    2015-03-01

    Full Text Available This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., ‘S-Index’ before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p 0.99 and during the Mueller maneuver (p > 0.99. The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults.

  11. Repeatability of measurements of packed cell volume and egg count as indicators of endoparasite load and their relationship with sheep productivity.

    Science.gov (United States)

    Bekele, T; Kasali, O B; Rege, J E

    1991-12-01

    Monthly measurements of packed cell volume (PCV) and nematode and trematode eggs per gram (EPG) were made in Ethiopian highland sheep at Debre Berhan, Dejen, Deneba, Tulu Meko and Wereilu from June 1988 to December 1989. High frequencies of low PCV, high nematode EPG and high trematode EPG were found at Tulu Meko. Among the productivity traits examined, body condition scores and live-weights were significantly (P less than 0.05) associated with differences in PCV and nematode and trematode EPG levels at most sites. The lambing interval was, however, not significantly (P greater than 0.05) affected by these variables. Monthly repeatabilities of PCV, body weight and body condition scores were 0.44 +/- 0.01, 0.71 +/- 0.01 and 0.35 +/- 0.01, respectively, while those of nematode (0.09 +/- 0.01) and trematode EPGs (0.20 +/- 0.02) were much lower. The high repeatability for PCV indicates that it was less affected by the variable factors influencing egg output, and hence it could be utilized in conjunction with nematode and trematode EPG levels for endoparasite monitoring. Repeatability of the lambing interval across parities was 0.43 +/- 0.14.

  12. Relationship between measures of aerobic fitness, speed and repeated sprint ability in full and part time youth soccer players.

    Science.gov (United States)

    Gibson, N; Currie, J; Johnston, R; Hill, J

    2013-02-01

    The aim of the study was to investigate the relationship between repeated sprint ability (RSA) involving changes in direction, short linear sprinting and aerobic capacity in young elite soccer players. A secondary aim was to assess any differences in performance of these assessments between players of different age groups. Thirty-two male adolescent soccer players belonging to the same elite club academy were assessed for RSA comprising 6 x 40m efforts interspersed by 25s recovery, linear sprinting speed over 15m, and aerobic capacity via the YYIE2 assessment. There was a significant correlation between performance in the YYIE2 and RSA total time, RSA fastest sprint and RSA percentage decrement (r = -0.71, -0.53, and -0.52 respectively. Psprint (Psprinting. Assessments of RSA over 40m and incorporating changes of direction appear to be significantly correlated with YYIE2 performance in young elite level soccer players. In addition older players performed significantly better in the YYIE2 assessment and RSA protocol but not in short linear sprinting. These results have implications for the design of assessment protocols for young elite soccer players of different ages.

  13. Very long Detection Times after High and repeated intake of Heroin and Methadone, measured in Oral Fluid

    Directory of Open Access Journals (Sweden)

    Vindenes V.

    2014-12-01

    Full Text Available When detection times for psychoactive drugs in oral fluid are reported, they are most often based on therapeutic doses administered in clinical studies. Repeated ingestions of high doses, as seen after drug abuse, are however likely to cause positive samples for extended time periods. Findings of drugs of abuse in oral fluid might lead to negative sanctions, and the knowledge of detection times of these drugs are important to ensure correct interpretation. The aim of this study was to investigate the detection times of opioids in oral fluid. 25 patients with a history of heavy drug abuse admitted to a detoxification ward were included. Oral fluid and urine were collected daily and, if the patient gave consent, a blood sample was drawn during the first five days after admission. Morphine, codeine and/or 6-monoacetyl morphine (6-MAM were found in oral fluid and/or urine from 20 patients. The maximum detection times in oral fluid for codeine, morphine and 6-MAM were 1, 3 and 8 days, respectively. Positive oral fluid samples were interspersed with negative samples, mainly for concentrations around cut off. Elimination curves for methadone in oral fluid were found for two subjects, and the detection times were 5 and 8 days. Oral fluid is likely to become a good method for detection of drug abuse in the future

  14. Design, Analysis, and Presentation of Crossover Trials

    OpenAIRE

    Guyatt Gordon H; Vail Andy; Wu Ping; Chan An-Wen; Mills Edward J; Altman Douglas G

    2009-01-01

    Abstract Objective Although crossover trials enjoy wide use, standards for analysis and reporting have not been established. We reviewed methodological aspects and quality of reporting in a representative sample of published crossover trials. Methods We searched MEDLINE for December 2000 and identified all randomized crossover trials. We abstracted data independently, in duplicate, on 14 design criteria, 13 analysis criteria, and 14 criteria assessing the data presentation. Results We identif...

  15. Spin-crossover materials properties and applications

    CERN Document Server

    Halcrow, Malcolm A

    2013-01-01

    The phenomenon of spin-crossover has a large impact on the physical properties of a solid material, including its colour, magnetic moment, and electrical resistance. Some materials also show a structural phase change during the transition. Several practical applications of spin-crossover materials have been demonstrated including display and memory devices, electrical and electroluminescent devices, and MRI contrast agents. Switchable liquid crystals, nanoparticles, and thin films of spin-crossover materials have also been achieved. Spin-Crossover Materials: Properties and Applicat

  16. Becoming a crossover-competent DSB.

    Science.gov (United States)

    Lake, Cathleen M; Hawley, R Scott

    2016-06-01

    The proper execution of meiotic recombination (or crossing over) is essential for chromosome segregation during the first meiotic division, and thus this process is regulated by multiple, and often elaborate, mechanisms. Meiotic recombination begins with the programmed induction of DNA double-strand breaks (DSBs), of which only a subset are selected to be repaired into crossovers. This crossover selection process is carried out by a number of pro-crossover proteins that regulate the fashion in which DSBs are repaired. Here, we highlight recent studies regarding the process of DSB fate selection by a family of pro-crossover proteins known as the Zip-3 homologs.

  17. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  18. Comparison of intraclass correlation coefficient estimates and standard errors between using cross-sectional and repeated measurement data: the Safety Check cluster randomized trial.

    Science.gov (United States)

    Ip, Edward H; Wasserman, Richard; Barkin, Shari

    2011-03-01

    Designing cluster randomized trials in clinical studies often requires accurate estimates of intraclass correlation, which quantifies the strength of correlation between units, such as participants, within a cluster, such as a practice. Published ICC estimates, even when available, often suffer from the problem of wide confidence intervals. Using data from a national, randomized, controlled study concerning violence prevention for children--the Safety Check--we compare the ICC values derived from two approaches only baseline data and using both baseline and follow-up data. Using a variance component decomposition approach, the latter method allows flexibility in handling complex data sets. For example, it allows for shifts in the outcome variable over time and for an unbalanced cluster design. Furthermore, we evaluate the large-sample formula for ICC estimates and standard errors using the bootstrap method. Our findings suggest that ICC estimates range from 0.012 to 0.11 for providers within practice and range from 0.018 to 0.11 for families within provider. The estimates derived from the baseline-only and repeated-measurements approaches agree quite well except in cases in which variation over repeated measurements is large. The reductions in the widths of ICC confidence limits from using repeated measurement over baseline only are, respectively, 62% and 42% at the practice and provider levels. The contribution of this paper therefore includes two elements, which are a methodology for improving the accuracy of ICC, and the reporting of such quantities for pediatric and other researchers who are interested in designing clustered randomized trials similar to the current study.

  19. The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains.

    Science.gov (United States)

    Iannetta, Danilo; Qahtani, Ahmad; Mattioni Maturana, Felipe; Murias, Juan Manuel

    2017-09-01

    A breaking-point in the near-infrared spectroscopy (NIRS)-derived deoxygenated haemoglobin ([HHb]) profile towards the end of a ramp incremental (RI) cycling test has been associated to the respiratory compensation point (RCP). Despite the physiological value of this measure, its repeatability remains unknown. The aim was to examine the repeatability of the [HHb] breaking-point ([HHb]BP) and its association to RCP during a RI cycling test. A repeated measures design was performed on 11 males (30.5±8.4 year; 76.5±8.4kg) and 4 females (30.5±5.9 year; 61.9±4.4 Kg). Gas exchange and NIRS [HHb] data were collected during RI tests performed on two different days separated by 48h. The [HHb]BP and the RCP were determined and compared for each trial. The [HHb]BP and the respiratory compensation point (RCP) occurred at the same VO2 in test 1 and test 2 ([HHb]BP: 3.49±0.52Lmin(-1) test 1; 3.48±0.45Lmin(-1) test 2; RCP: 3.38±0.40Lmin(-1) test 1; 3.38±0.44Lmin(-1) test 2) (P>0.05). The VO2 associated with the [HHb]BP and the VO2 at RCP were not significantly different from each other either in test 1 as well as in test 2 (P>0.05). Neither test 1 nor test 2 showed significant mean average error between the VO2 at the [HHb]BP and RCP using Bland & Altman plots. The [HHb]BP is a repeatable measure that consistently occurs towards the end of a RI test. The association between the [HHb]BP and the RCP reinforces the idea that these parameters may share similar mechanistic basis. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  1. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  2. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  3. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening

  4. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  5. The mechanocaloric potential of spin crossover compounds

    OpenAIRE

    Sandeman, K. G.

    2016-01-01

    We present a first evaluation of the potential for spin crossover (SCO) compounds to be considered as a new class of giant mechanocaloric effect material. From literature data on the variation of the spin crossover temperature with pressure, we estimate the maximum available adiabatic temperature change for several compounds and the relatively low pressures that may be required to observe these effects.

  6. 24 CFR 3285.701 - Electrical crossovers.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Electrical crossovers. 3285.701... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.701 Electrical crossovers. Multi-section homes with electrical wiring in more than one section...

  7. Effects of ambient air pollution on functional status in patients with chronic congestive heart failure: a repeated-measures study

    Directory of Open Access Journals (Sweden)

    Phillips Russell S

    2007-09-01

    Full Text Available Abstract Background Studies using administrative data report a positive association between ambient air pollution and the risk of hospitalization for congestive heart failure (HF. Circulating levels of B-type natriuretic peptide (BNP are directly associated with cardiac hemodynamics and symptom severity in patients with HF and, therefore, serves as a marker of functional status. We tested the hypothesis that BNP levels would be positively associated with short-term changes in ambient pollution levels among 28 patients with chronic stable HF and impaired systolic function. Methods BNP was measured in whole blood at 0, 6, and 12 weeks. We used linear mixed models to evaluate the association between fine particulate matter (PM2.5, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and black carbon and log(BNP. Lags of 0 to 3 days were considered in separate models. We calculated the intraclass correlation coefficient and within-subject coefficient of variation as measures of reproducibility. Results We found no association between any pollutant and measures of BNP at any lag. For example, a 10 μg/m3 increase in PM2.5 was associated with a 0.8% (95% CI: -16.4, 21.5; p = 0.94 increase in BNP on the same day. The within-subject coefficient of variation was 45% on the natural scale and 9% on the log scale. Conclusion These results suggest that serial BNP measurements are unlikely to be useful in a longitudinal study of air pollution-related acute health effects. The magnitude of expected ambient air pollution health effects appears small in relation to the considerable within-person variability in BNP levels in this population.

  8. A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force.

    Science.gov (United States)

    Hall, Rick S; Desmoulin, Geoffrey T; Milner, Theodore E

    2008-12-01

    Miniature sensors that could measure forces applied by the fingers and hand without interfering with manual dexterity or range of motion would have considerable practical value in ergonomics and rehabilitation. In this study, techniques have been developed to use inexpensive pressure-sensing resistors (FSRs) to accurately measure compression force. The FSRs are converted from pressure-sensing to force-sensing devices. The effects of nonlinear response properties and dependence on loading history are compensated by signal conditioning and calibration. A fourth-order polynomial relating the applied force to the current voltage output and a linearly weighted sum of prior outputs corrects for sensor hysteresis and drift. It was found that prolonged (>20h) shear force loading caused sensor gain to change by approximately 100%. Shear loading also had the effect of eliminating shear force effects on sensor output, albeit only in the direction of shear loading. By applying prolonged shear loading in two orthogonal directions, the sensors were converted into pure compression sensors. Such preloading of the sensor is, therefore, required prior to calibration. The error in compression force after prolonged shear loading and calibration was consistently industrial design applications where measurements of finger and hand force are needed.

  9. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25-obese (≥30-....79-0.94) and 0.80 (0.72-0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76-1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62-1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations...

  10. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  11. Repeated-measure validation of craniofacial metrics from three-dimensional surface scans: application to medical genetics

    Science.gov (United States)

    Lauer, Eric A.; Corner, Brian D.; Li, Peng; Beecher, Robert M.; Deutsch, Curtis

    2002-03-01

    Traditionally, medical geneticists have employed visual inspection (anthroposcopy) to clinically evaluate dysmorphology. In the last 20 years, there has been an increasing trend towards quantitative assessment to render diagnosis of anomalies more objective and reliable. These methods have focused on direct anthropometry, using a combination of classical physical anthropology tools and new instruments tailor-made to describe craniofacial morphometry. These methods are painstaking and require that the patient remain still for extended periods of time. Most recently, semiautomated techniques (e.g., structured light scanning) have been developed to capture the geometry of the face in a matter of seconds. In this paper, we establish that direct anthropometry and structured light scanning yield reliable measurements, with remarkably high levels of inter-rater and intra-rater reliability, as well as validity (contrasting the two methods).

  12. 躯体X线测量板的研制和应用%Validation and repeatability of Limb X Film Measuring Plate

    Institute of Scientific and Technical Information of China (English)

    卫小春; 柴旭峰; 许趁心

    2008-01-01

    Objective To study the efficacy and repeatability of the Limb X Film Measuring Plate (LXMP)in clinical x film measurement of lengths and angles of limbs.Methods The LXMP was de- signed and manufactured for testing.Three known points in 9 templates were taken as golden standards.which were to be compared with measuring results of these projected points on the X film for testing efficacy of LXMP.Twenty-one patients with knees osteoarthritis were selected.The lengths and angles of their lower limbs were measured twice with the help of LXMP by an observer at different time intervals for testing in. Tra-observer repeatability.Two observers measured once on films at the same time for testing inter-observer repeatability.The correlation coefficients,mean absolute difierences between the repeated measurements,and error rate were calculated. Results The points on LXMP could be seen clearly on X film.Validation tests showed the differences in angle measurement between golden standards and measuring results for those pro- jeted points on the X film were insignificant.with mean absolute difference being O.10.-0.21,error rate being 0.12%-3.15%and r being close to 1.The differences in length measurement were insignificant ei- ther,with mean absolute differenee being 0.05 cm-0.16 cm.error rate being 0.12%-o.28%and r being close to 1.The intra-observer repeatability test for beth angles and lengths showed that r was close to I.mean absolute diffefences 0.55.and 0.1-0.37cm and error rate 0.3l%-O.97%.while the inter-observer re- peatability test showed that r was close to 1.mean absolute difierences o.39.and0.05-0.13cm and error rate O.16%-O.35%. Conclusion The Limb X Film Measuring Plate Can be used for accurately mcasuring limb lengths and angles with good efficacy and repeatability.%目的 介绍躯体X线测量板的制作方法 ,探讨其有效性、重复性,为临床X线测量提供一套精确、实用、经济的方法 和工具.方法 设计和制作躯体X线

  13. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  14. Evaluation of Multiple Imputation in Missing Data Analysis: An Application on Repeated Measurement Data in Animal Science

    Directory of Open Access Journals (Sweden)

    Gazel Ser

    2015-12-01

    Full Text Available The purpose of this study was to evaluate the performance of multiple imputation method in case that missing observation structure is at random and completely at random from the approach of general linear mixed model. The application data of study was consisted of a total 77 heads of Norduz ram lambs at 7 months of age. After slaughtering, pH values measured at five different time points were determined as dependent variable. In addition, hot carcass weight, muscle glycogen level and fasting durations were included as independent variables in the model. In the dependent variable without missing observation, two missing observation structures including Missing Completely at Random (MCAR and Missing at Random (MAR were created by deleting the observations at certain rations (10% and 25%. After that, in data sets that have missing observation structure, complete data sets were obtained using MI (multiple imputation. The results obtained by applying general linear mixed model to the data sets that were completed using MI method were compared to the results regarding complete data. In the mixed model which was applied to the complete data and MI data sets, results whose covariance structures were the same and parameter estimations and standard estimations were rather close to the complete data are obtained. As a result, in this study, it was ensured that reliable information was obtained in mixed model in case of choosing MI as imputation method in missing observation structure and rates of both cases.

  15. Bayesian hierarchical joint modeling of repeatedly measured continuous and ordinal markers of disease severity: Application to Ugandan diabetes data.

    Science.gov (United States)

    Buhule, O D; Wahed, A S; Youk, A O

    2017-08-22

    Modeling of correlated biomarkers jointly has been shown to improve the efficiency of parameter estimates, leading to better clinical decisions. In this paper, we employ a joint modeling approach to a unique diabetes dataset, where blood glucose (continuous) and urine glucose (ordinal) measures of disease severity for diabetes are known to be correlated. The postulated joint model assumes that the outcomes are from distributions that are in the exponential family and hence modeled as multivariate generalized linear mixed effects model associated through correlated and/or shared random effects. The Markov chain Monte Carlo Bayesian approach is used to approximate posterior distribution and draw inference on the parameters. This proposed methodology provides a flexible framework to account for the hierarchical structure of the highly unbalanced data as well as the association between the 2 outcomes. The results indicate improved efficiency of parameter estimates when blood glucose and urine glucose are modeled jointly. Moreover, the simulation studies show that estimates obtained from the joint model are consistently less biased and more efficient than those in the separate models. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  17. The Effects of Repeat Testing, Malingering, and Traumatic Brain Injury on Computerized Measures of Visuospatial Memory Span.

    Science.gov (United States)

    Woods, David L; Wyma, John M; Herron, Timothy J; Yund, E W

    2015-01-01

    Spatial span tests (SSTs) such as the Corsi Block Test (CBT) and the SST of the Wechsler Memory Scale are widely used to assess deficits in spatial working memory. We conducted three experiments to evaluate the test-retest reliability and clinical sensitivity of a new computerized spatial span test (C-SST) that incorporates psychophysical methods to improve the precision of spatial span measurement. In Experiment 1, we analyzed C-SST test-retest reliability in 49 participants who underwent three test sessions at weekly intervals. Intraclass correlation coefficients (ICC) were higher for a psychophysically derived mean span (MnS) metric (0.83) than for the maximal span and total correct metrics used in traditional spatial-span tests. Response times (ReTs) also showed high ICCs (0.93) that correlated negatively with MnS scores and correlated positively with response-time latencies from other tests of processing speed. Learning effects were insignificant. Experiment 2 examined the performance of Experiment 1 participants when instructed to feign symptoms of traumatic brain injury (TBI): 57% showed abnormal MnS z-scores. A MnS z-score cutoff of 3.0 correctly classified 36% of simulated malingerers and 91% of the subgroup of 11 control participants with abnormal spans. Malingerers also made more substitution errors than control participants with abnormal spans (sensitivity = 43%, specificity = 91%). In addition, malingerers showed no evidence of ReT slowing, in contrast to significant abnormalities seen on other malingered tests of processing speed. As a result, differences between ReT z-scores and z-scores on other processing speed tests showed very high sensitivity and specificity in distinguishing malingering and control participants with either normal or abnormal spans. Experiment 3 examined C-SST performance in a group of patients with predominantly mild TBI: neither MnS nor ReT z-scores showed significant group-level abnormalities. The C-SST improves the

  18. The choice in meiosis - defining the factors that influence crossover or non-crossover formation.

    Science.gov (United States)

    Youds, Jillian L; Boulton, Simon J

    2011-02-15

    Meiotic crossovers are essential for ensuring correct chromosome segregation as well as for creating new combinations of alleles for natural selection to take place. During meiosis, excess meiotic double-strand breaks (DSBs) are generated; a subset of these breaks are repaired to form crossovers, whereas the remainder are repaired as non-crossovers. What determines where meiotic DSBs are created and whether a crossover or non-crossover will be formed at any particular DSB remains largely unclear. Nevertheless, several recent papers have revealed important insights into the factors that control the decision between crossover and non-crossover formation in meiosis, including DNA elements that determine the positioning of meiotic DSBs, and the generation and processing of recombination intermediates. In this review, we focus on the factors that influence DSB positioning, the proteins required for the formation of recombination intermediates and how the processing of these structures generates either a crossover or non-crossover in various organisms. A discussion of crossover interference, assurance and homeostasis, which influence crossing over on a chromosome-wide and genome-wide scale - in addition to current models for the generation of interference - is also included. This Commentary aims to highlight recent advances in our understanding of the factors that promote or prevent meiotic crossing over.

  19. Crossover versus parallel designs: dose-escalation design comparisons for first-in-human studies.

    Science.gov (United States)

    Yan, Zhiwu; Hosmane, Balakrishna; Locke, Charles

    2013-01-01

    We study the statistical efficiency for rising-dose designs in the context of first-in-human studies. Specifically, we identify a class of crossover designs that are appealing in terms of both subject safety and statistical efficiency and, for a three-period, two-panel design in such a class, we compare its A-efficiency relative to the corresponding parallel designs and optimal/efficient crossover designs, respectively, under various plausible models. In the meantime, we also evaluate the impact of inclusion of baseline measurements as a covariate in the statistical analysis, for both crossover and parallel studies.

  20. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  1. Net baryon fluctuations from a crossover equation of state

    Energy Technology Data Exchange (ETDEWEB)

    Kapusta, J.; Albright, M. [University of Minnesota, School of Physics and Astronomy, Minneapolis, MN (United States); Young, C. [Michigan State University, National Superconducting Cyclotron Laboratory, East Lansing, MI (United States)

    2016-08-15

    We have constructed an equation of state which smoothly interpolates between an excluded-volume hadron resonance gas at low energy density to a plasma of quarks and gluons at high energy density. This crossover equation of state agrees very well with lattice calculations at both zero and nonzero baryon chemical potential. We use it to compute the variance, skewness, and kurtosis of fluctuations of baryon number, and compare to measurements of proton number fluctuations in central Au-Au collisions as measured by the STAR Collaboration in a beam energy scan at the Relativistic Heavy-Ion Collider. The crossover equation of state can reproduce the data if the fluctuations are frozen out at temperatures well below than the average chemical freeze-out. (orig.)

  2. Net Baryon Fluctuations from a Crossover Equation of State

    CERN Document Server

    Kapusta, J; Young, C

    2016-01-01

    We have constructed an equation of state which smoothly interpolates between an excluded volume hadron resonance gas at low energy density to a plasma of quarks and gluons at high energy density. This crossover equation of state agrees very well with lattice calculations at both zero and nonzero baryon chemical potential. We use it to compute the variance, skewness, and kurtosis of fluctuations of baryon number, and compare to measurements of proton number fluctuations in central Au-Au collisions as measured by the STAR collaboration in a beam energy scan at the Relativistic Heavy Ion Collider. The crossover equation of state can reproduce the data if the fluctuations are frozen out at temperatures well below than the average chemical freeze-out.

  3. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2017-09-04

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  4. Measurement of Surface Displacement and Deformation of Mass Movements Using Least Squares Matching of Repeat High Resolution Satellite and Aerial Images

    Directory of Open Access Journals (Sweden)

    Misganu Debella-Gilo

    2012-01-01

    Full Text Available Displacement and deformation are fundamental measures of Earth surface mass movements such as glacier flow, rockglacier creep and rockslides. Ground-based methods of monitoring such mass movements can be costly, time consuming and limited in spatial and temporal coverage. Remote sensing techniques, here matching of repeat optical images, are increasingly used to obtain displacement and deformation fields. Strain rates are usually computed in a post-processing step based on the gradients of the measured velocity field. This study explores the potential of automatically and directly computing velocity, rotation and strain rates on Earth surface mass movements simultaneously from the matching positions and the parameters of the geometric transformation models using the least squares matching (LSM approach. The procedures are exemplified using bi-temporal high resolution satellite and aerial images of glacier flow, rockglacier creep and land sliding. The results show that LSM matches the images and computes longitudinal strain rates, transverse strain rates and shear strain rates reliably with mean absolute deviations in the order of 10−4 (one level of significance below the measured values as evaluated on stable grounds. The LSM also improves the accuracy of displacement estimation of the pixel-precision normalized cross-correlation by over 90% under ideal (simulated circumstances and by about 25% for real multi-temporal images of mass movements.

  5. Lumbar spine and pelvic posture between standing and sitting: a radiologic investigation including reliability and repeatability of the lumbar lordosis measure.

    Science.gov (United States)

    De Carvalho, Diana E; Soave, David; Ross, Kim; Callaghan, Jack P

    2010-01-01

    Sitting has been identified as a cause of mechanical low back pain. The purpose of this study was to use plain film x-rays to measure lumbar spine and pelvic posture differences between standing and sitting. Eight male subjects were radiographed standing and sitting in an automobile seat. Measures of lumbar lordosis, intervertebral disk angles, lumbosacral angle, lumbosacral lordosis, and sacral tilt were completed. One-way analysis of variance (alpha = .05) was conducted on the variables stated above. A Bland-Altman analysis was conducted to assess agreement and repeatability of the lumbar lordosis angle using 2 raters. Lumbar lordosis values in standing (average, 63 degrees +/- 15 degrees ) and sacral inclination (average, 43 degrees +/- 10 degrees ) decreased by 43 degrees and 44 degrees , respectively, in sitting. Intervertebral joint angles in sitting underwent substantial flexion (L1/L2-5 degrees [+/-3 degrees ], L2/L3-7 degrees [+/-3 degrees ], L3/L4-8 degrees [+/-3 degrees ], L4/L5-13 degrees [+/-3 degrees ], and L5/S1-4 degrees [+/-10 degrees ]). Measures of lumbar lordosis; intervertebral disk angles between L2/L3, L3/L4, and L4/L5; lumbosacral lordosis; lumbosacral angle; and sacral tilt were significantly decreased between standing and sitting (P posture should be investigated because they may play a role in preventing injury and low back pain. Copyright 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. Universally optimal crossover designs under subject dropout

    OpenAIRE

    Zheng, Wei

    2013-01-01

    Subject dropout is very common in practical applications of crossover designs. However, there is very limited design literature taking this into account. Optimality results have not yet been well established due to the complexity of the problem. This paper establishes feasible, as well as necessary and sufficient conditions for a crossover design to be universally optimal in approximate design theory in the presence of subject dropout. These conditions are essentially linear equations with re...

  7. 基于同频RF直放站的回波测量方法%Technique of measuring the echo for RF repeaters in single frequency networks

    Institute of Scientific and Technical Information of China (English)

    陈哲; 宋葛

    2011-01-01

    直放站的同频转发模式存在收发天线间互耦的问题,接收天线在接收主基站的信号时,同时接收到直放站发射天线发射的信号,以同频RF直放站调试隔离度为技术背景,提出了同频RF直放站的回波测量方法.该方法利用CAZAC码实现的初估计快速地估计出回波信道的特性,自适应LMS算法的使用可以进一步跟踪信道的变化.通过MATLAB仿真后,在数字硬件平台上用FPGA实现该方法,并用数字电视信号CMMB做为信号源对系统进行了测试,结果说明此种测量方法准确、实用.%The signal transition mode of repeater which works on the same frequency has some troubles on signal coupling between receive and transmit aerials,the signal from transmit aerial may leak out into receive aerial. This paper presents a method of measuring the echo under the context of isolation test for RF repeaters in single frequency networks. The experimental apparatus firstly uses CAZAC code as the method of channel initial estimation, secondly uses LMS arithmetic to track the change of the channel. After the MATLAB simulation realization has been achieved by FPGA on real digital hardware board. The result of test which uses DTV signal (CMMB) as the source proves the function of method achieved accurately.

  8. Repeat, Low Altitude Measurements of Vegetation Status and Biomass Using Manned Aerial and UAS Imagery in a Piñon-Juniper Woodland

    Science.gov (United States)

    Krofcheck, D. J.; Lippitt, C.; Loerch, A.; Litvak, M. E.

    2015-12-01

    Measuring the above ground biomass of vegetation is a critical component of any ecological monitoring campaign. Traditionally, biomass of vegetation was measured with allometric-based approach. However, it is also time-consuming, labor-intensive, and extremely expensive to conduct over large scales and consequently is cost-prohibitive at the landscape scale. Furthermore, in semi-arid ecosystems characterized by vegetation with inconsistent growth morphologies (e.g., piñon-juniper woodlands), even ground-based conventional allometric approaches are often challenging to execute consistently across individuals and through time, increasing the difficulty of the required measurements and consequently the accuracy of the resulting products. To constrain the uncertainty associated with these campaigns, and to expand the extent of our measurement capability, we made repeat measurements of vegetation biomass in a semi-arid piñon-juniper woodland using structure-from-motion (SfM) techniques. We used high-spatial resolution overlapping aerial images and high-accuracy ground control points collected from both manned aircraft and multi-rotor UAS platforms, to generate digital surface model (DSM) for our experimental region. We extracted high-precision canopy volumes from the DSM and compared these to the vegetation allometric data, s to generate high precision canopy volume models. We used these models to predict the drivers of allometric equations for Pinus edulis and Juniperous monosperma (canopy height, diameter at breast height, and root collar diameter). Using this approach, we successfully accounted for the carbon stocks in standing live and standing dead vegetation across a 9 ha region, which contained 12.6 Mg / ha of standing dead biomass, with good agreement to our field plots. Here we present the initial results from an object oriented workflow which aims to automate the biomass estimation process of tree crown delineation and volume calculation, and partition

  9. Assessing Different Crossover Operators for Travelling Salesman Problem

    Directory of Open Access Journals (Sweden)

    Imtiaz Hussain Khan

    2015-10-01

    Full Text Available Many crossover operators have been proposed in literature on evolutionary algorithms, however, it is still unclear which crossover operator works best for a given optimization problem. In this study, eight different crossover operators specially designed for travelling salesman problem, namely, Two-Point Crossover, Partially Mapped Crossover, Cycle Crossover, Shuffle Crossover, Edge Recombination Crossover, Uniform Order-based Crossover, Sub-tour Exchange Crossover, and Sequential Constructive Crossover are evaluated empirically. The select crossover operators were implemented to build an experimental setup upon which simulations were run. Four benchmark instances of travelling salesman problem, two symmetric (ST70 and TSP225 and two asymmetric (FTV100 and FTV170, were used to thoroughly assess the select crossover operators. The performance of these operators was analyzed in terms of solution quality and computational cost. It was found that Sequential Constructive Crossover outperformed other operators in attaining 'good' quality solution, whereas Two-Point Crossover outperformed other operators in terms of computational cost. It was also observed that the performance of different crossover operators is much better for relatively small number of cities, both in terms of solution quality and computational cost, however, for relatively large number of cities their performance greatly degrades

  10. Design, analysis, and presentation of crossover trials

    Directory of Open Access Journals (Sweden)

    Guyatt Gordon H

    2009-04-01

    Full Text Available Abstract Objective Although crossover trials enjoy wide use, standards for analysis and reporting have not been established. We reviewed methodological aspects and quality of reporting in a representative sample of published crossover trials. Methods We searched MEDLINE for December 2000 and identified all randomized crossover trials. We abstracted data independently, in duplicate, on 14 design criteria, 13 analysis criteria, and 14 criteria assessing the data presentation. Results We identified 526 randomized controlled trials, of which 116 were crossover trials. Trials were drug efficacy (48%, pharmacokinetic (28%, and nonpharmacologic (30%. The median sample size was 15 (interquartile range 8–38. Most (72% trials used 2 treatments and had 2 periods (64%. Few trials reported allocation concealment (17% or sequence generation (7%. Only 20% of trials reported a sample size calculation and only 31% of these considered pairing of data in the calculation. Carry-over issues were addressed in 29% of trial's methods. Most trials reported and defended a washout period (70%. Almost all trials (93% tested for treatment effects using paired data and also presented details on by-group results (95%. Only 29% presented CIs or SE so that data could be entered into a meta-analysis. Conclusion Reports of crossover trials frequently omit important methodological issues in design, analysis, and presentation. Guidelines for the conduct and reporting of crossover trials might improve the conduct and reporting of studies using this important trial design.

  11. Thermodynamics of ultracold Bose gases at a dimensional crossover

    Science.gov (United States)

    Labouvie, Ralf; Vogler, Andreas; Guarrera, Vera; Ott, Herwig

    2013-05-01

    We have studied the thermodynamics of ultracold Bose gases in the crossover from a three-dimensional to a one-dimensional regime. In our experiment, we use a focused electron-beam to probe in situ atomic density distributions with high temporal and spatial resolution. Starting with a Bose-Einstein-Condensate in a single beam optical dipole trap we can create one-dimensional systems by loading the atoms in a two-dimensional blue-detuned optical lattice. With increasing strength of the lattices we go from a three-dimensional into a one-dimensional system. Furthermore we tune the interaction strengths of the one-dimensional quantum-gases from weak (quasi-condensate) to strong (Tonks-Girardeau). By measuring the density profiles and applying an inverse Abel-Transformation we extract the equation of states of these systems and characterize the crossover from the three-dimensional to the one-dimensional regime.

  12. Thermodynamic characterization of two novel spin-crossover complexes

    Institute of Scientific and Technical Information of China (English)

    DING Bin; WANG Hongmei; YI Long; CHENG Peng; LI Licun; ZHAI Yuping; LIAO Daizheng; YAN Shiping; JIANG Zonghui

    2003-01-01

    Two novel FeⅡspin crossover complexes [Fe(L1)3](BF4)2·5H2O (1) and [Fe(L2)3](BF4)2·2H2O (2) with 4-NHR-1,2,4-triazole (R = isopropyl, L1; cyclohexyl, L2) were synthesized. 1 and 2 remain white at room temperature, whereas they turn purple at liquid temperature. Variable temperature optical detection and magnetic susceptibilities measurement show that the spin-crossover phenomenon for 1 was observed between 120 K and 170 K. The hysteresis loop is about 10 K. The Tc temperature of 2 is 190 K, but no thermal hysteresis loop was found. The molar thermodynamic functions and the microscopic parameters were obtained from the theoretical analysis in terms of the domain model, two level Ising model and regular solution model, respectively.

  13. An inverted crossover resonance within one Zeeman manifold

    CERN Document Server

    Salter, Liam A

    2016-01-01

    We detect and describe inverted crossover resonances in $\\pi$-driven four-level systems where $\\Delta F$ can be zero. The signal is observed through sub-Doppler frequency modulation spectroscopy of the $(6s^{2})$ $^{1}S_{0}$ $-$ $(6s6p)$ $^{3}P_{1}$ transition in $^{171}$Yb, where the nuclear spin $I=1/2$. The resonance is inherently insensitive to first-order Zeeman shifts. Optical frequency measurements of the $F'=1/2$ hyperfine line recorded over several weeks demonstrate a statistical uncertainty of $2\\times10^{-11}$. The inverted crossover resonance found with the $F'=3/2$ line is used for 556 nm laser frequency stabilization and this light cools $^{171}$Yb atoms in a two-stage magneto-optical trap. We test the atomic cloud temperatures on the frequency instability of the light.

  14. The sphaleron rate through the electroweak cross-over

    DEFF Research Database (Denmark)

    D'Onofrio, Michela; Rummukainen, Kari; Tranberg, Anders

    2012-01-01

    Using lattice simulations, we measure the sphaleron rate in the Standard Model as a function of temperature through the electroweak cross-over, for the Higgs masses m(H) = 115 and m(H) = 160GeV. We pay special attention to the shutting off of the baryon rate as the temperature is lowered. This qu......Using lattice simulations, we measure the sphaleron rate in the Standard Model as a function of temperature through the electroweak cross-over, for the Higgs masses m(H) = 115 and m(H) = 160GeV. We pay special attention to the shutting off of the baryon rate as the temperature is lowered....... This quantity enters computations of Baryogenesis via Leptogenesis, where non-zero lepton number is converted into non-zero baryon number by equilibrium sphaleron transitions. Combining existing numerical methods applicable in the symmetric and broken electroweak phases, we find the temperature dependence...... of the sphaleron rate at very high temperature, through the electroweak cross-over transition, and deep into the broken phase....

  15. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  16. A Mathematical Unification of Geometric Crossovers Defined on Phenotype Space

    OpenAIRE

    Yoon, Yourim; Kim, Yong-Hyuk; Moraglio, Alberto; Moon, Byung-Ro

    2009-01-01

    Geometric crossover is a representation-independent definition of crossover based on the distance of the search space interpreted as a metric space. It generalizes the traditional crossover for binary strings and other important recombination operators for the most frequently used representations. Using a distance tailored to the problem at hand, the abstract definition of crossover can be used to design new problem specific crossovers that embed problem knowledge in the search. This paper is...

  17. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim;

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...

  18. Studies on Methanol Crossover in Liquid-Feed Direct Methanol Pem Fuel Cells

    Science.gov (United States)

    Narayanan, S. R.

    1995-01-01

    The performance of liquid feed direct methanol fuel cells using various types of Nafion membranes as the solid polymer electrolyte have been studied. The rate of fuel crossover and electrical performance has been measured for cells with Nafion membranes of various thicknesses and equivalent weights. The crossover rate is found to decrease with increasing thickness and applied current. The dependence of crossover rate on current density can be understood in terms of a simple linear diffusion model which suggests that the crossover rate can be influenced by the electrode structure in addition to the membrane. The studies suggest that Nafion EW 1500 is a very promising alternate to Nafion EW 1100 for direct methanol fuel cells.

  19. A matched crossover design for clinical trials.

    Science.gov (United States)

    Simon, Laura J; Chinchilli, Vernon M

    2007-09-01

    Two design principles are used frequently in clinical trials: 1) A subject is "matched" or "paired" with a similar subject to reduce the chance that other variables obscure the primary comparison of interest. 2) A subject serves as his/her own control by "crossing over" from one treatment to another during the course of an experiment. There are situations in which it may be advantageous to use the two design principles - crossing over and matching - simultaneously. That is, it may be advantageous to conduct a "paired crossover design," in which each subject, while paired with a similar subject, crosses over and receives each experimental treatment. In this paper, we describe two clinical trials conducted by the National Heart, Lung and Blood Institute's Asthma Clinical Research Network that used a paired 2x2 crossover design. The Beta Adrenergic Response by GEnotype (BARGE) Study compared the effects of regular use of inhaled albuterol on mildly asthmatic patients with different genotypes at the 16th position of the beta-agonist receptor gene. The Smoking Modulates Outcomes of Glucocorticoid (SMOG) Therapy in Asthma Study evaluated the hypothesis that smoking reduces the response to inhaled corticosteroids. For such paired crossover designs, the primary parameter of interest is typically the treatment-by-pairing interaction term. In evaluating the relative efficiency of the paired 2x2 crossover design to two independent crossover designs with respect to this interaction term, we show that the paired 2x2 crossover design is more efficient if the correlations between the paired members on the same treatments are greater than their correlations on different treatments. This condition should hold in most circumstances, and therefore the paired crossover design deserves serious consideration for any clinical trial in which the crossing over and matching of subjects is deemed simultaneously beneficial.

  20. Music intervention during daily weaning trials-A 6 day prospective randomized crossover trial.

    Science.gov (United States)

    Liang, Zhan; Ren, Dianxu; Choi, JiYeon; Happ, Mary Beth; Hravnak, Marylyn; Hoffman, Leslie A

    2016-12-01

    To examine the effect of patient-selected music intervention during daily weaning trials for patients on prolonged mechanical ventilation. Using a crossover repeated measures design, patients were randomized to music vs no music on the first intervention day. Provision of music was alternated for 6 days, resulting in 3 music and 3 no music days. During weaning trials on music days, data were obtained for 30min prior to music listening and continued for 60min while patients listened to selected music (total 90min). On no music days, data were collected for 90min. Outcome measures were heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), blood pressure (BP), dyspnea and anxiety assessed with a visual analog scale (VAS-D, VAS-A) and weaning duration (meanh per day on music and non-music days). Of 31 patients randomized, 23 completed the 6-day intervention. When comparisons were made between the 3 music and 3 no music days, there were significant decreases in RR and VAS-D and a significant increase in daily weaning duration on music days (pmusic days (pmusic during daily weaning trials is a simple, low-cost, potentially beneficial intervention for patients on prolonged mechanical ventilation. Further study is indicated to test ability of this intervention to promote weaning success and benefits earlier in the weaning process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Evaluation of the running-based anaerobic sprint test as a measure of repeated sprint ability in collegiate-level soccer players.

    Science.gov (United States)

    Keir, Daniel A; Thériault, Francis; Serresse, Olivier

    2013-06-01

    Repeated sprint ability (RSA) refers to an individual's ability to perform maximal sprints of short duration in succession with little recovery between sprints. The running-based anaerobic sprint test (RAST) has been adapted from the Wingate anaerobic test (WAnT) protocol as a tool to assess RSA and anaerobic power. The purpose of this study was to evaluate the relationship between performance variables and physiological responses obtained during the RAST and the WAnT using 8 collegiate-level soccer players. Participants performed a single trial of both the WAnT and the RAST. Breath-by-breath gas exchange was monitored throughout each trial, and blood lactate (BL) measures were recorded postexercise. The oxygen uptake (VO2) profile suggested that the RAST required greater contributions from aerobic metabolism although there was no difference in VO2peak (p < 0.05). Peak BL values were also similar between the RAST and the WAnT (p < 0.05). Neither peak physiological values nor performance variables (peak and mean power) were significantly correlated between protocols. The weak association in physiological responses indicates that different combinations of metabolic contributions exist between protocols, suggesting that individual performances on each test are not related in collegiate soccer players. Further studies on these relationships with players of other competitive levels and team sport athletes are warranted.

  2. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    Science.gov (United States)

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  3. Knowledge and skill retention of in-service versus preservice nursing professionals following an informal training program in pediatric cardiopulmonary resuscitation: a repeated-measures quasiexperimental study.

    Science.gov (United States)

    Sankar, Jhuma; Vijayakanthi, Nandini; Sankar, M Jeeva; Dubey, Nandkishore

    2013-01-01

    Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR) on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses) and final year undergraduate nursing students (preservice nurses) using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants-28 in-service and 46 preservice professionals-were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P = 0.08) while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P nurses performing better in knowledge test (10.5 versus 9.1, P = 0.01) and the preservice nurses performing better in skill test (9.8 versus 7.4, P skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  4. Direct and accurate measurement of CAG repeat configuration in the ataxin-1 (ATXN-1) gene by "dual-fluorescence labeled PCR-restriction fragment length analysis".

    Science.gov (United States)

    Lin, Jiang X; Ishikawa, Kinya; Sakamoto, Masaki; Tsunemi, Taiji; Ishiguro, Taro; Amino, Takeshi; Toru, Shuta; Kondo, Ikuko; Mizusawa, Hidehiro

    2008-01-01

    Spinocerebellar ataxia type 1 (SCA1; OMIM: #164400) is an autosomal dominant cerebellar ataxia caused by an expansion of CAG repeat, which encodes polyglutamine, in the ataxin-1 (ATXN1) gene. Length of polyglutamine in the ATXN1 protein is the critical determinant of pathogenesis of this disease. Molecular diagnosis of SCA1 is usually undertaken by assessing the length of CAG repeat configuration using primers spanning this configuration. However, this conventional method may potentially lead to misdiagnosis in assessing polyglutamine-encoding CAG repeat length, since CAT interruptions may be present within the CAG repeat configuration, not only in normal controls but also in neurologically symptomatic subjects. We developed a new method for assessing actual CAG repeat numbers not interrupted by CAT sequences. Polymerase chain reaction using a primer pair labeled with two different fluorescences followed by restriction enzyme digestion with SfaNI which recognizes the sequence "GCATC(N)(5)", lengths of actual CAG repeats that encode polyglutamine were directly detected. We named this method "dual fluorescence labeled PCR-restriction fragment length analysis". We found that numbers of actual CAG repeat encoding polyglutamine do not overlap between our cohorts of normal chromosomes (n=385) and SCA1 chromosomes (n=5). We conclude that the present method is a useful way for molecular diagnosis of SCA1.

  5. Spin-crossover molecule based thermoelectric junction

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Dibyajyoti [Chemistry and Physics of Materials Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore 560064 (India); Parida, Prakash [Institute for Theoretical Physics, University of Regensburg, D-93040 Regensburg (Germany); Pati, Swapan K. [Theoretical Sciences Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore 560064 (India)

    2015-05-11

    Using ab-initio numerical methods, we explore the spin-dependent transport and thermoelectric properties of a spin-crossover molecule (i.e., iron complex of 2-(1H-pyrazol-1-yl)-6-(1H-tetrazole-5-yl)pyridine) based nano-junction. We demonstrate a large magnetoresistance, efficient conductance-switching, and spin-filter activity in this molecule-based two-terminal device. The spin-crossover process also modulates the thermoelectric entities. It can efficiently switch the magnitude as well as spin-polarization of the thermocurrent. We find that thermocurrent is changed by ∼4 orders of magnitude upon spin-crossover. Moreover, it also substantially affects the thermopower and consequently, the device shows extremely efficient spin-crossover magnetothermopower generation. Furthermore, by tuning the chemical potential of electrodes into a certain range, a pure spin-thermopower can be achieved for the high-spin state. Finally, the reasonably large values of figure-of-merit in the presence and absence of phonon demonstrate a large heat-to-voltage conversion efficiency of the device. We believe that our study will pave an alternative way of tuning the transport and thermoelectric properties through the spin-crossover process and can have potential applications in generation of spin-dependent current, information storage, and processing.

  6. Simulated Conversations With Virtual Humans to Improve Patient-Provider Communication and Reduce Unnecessary Prescriptions for Antibiotics: A Repeated Measure Pilot Study

    Science.gov (United States)

    2017-01-01

    Background Despite clear evidence that antibiotics do not cure viral infections, the problem of unnecessary prescribing of antibiotics in ambulatory care persists, and in some cases, prescribing patterns have increased. The overuse of antibiotics for treating viral infections has created numerous economic and clinical consequences including increased medical costs due to unnecessary hospitalizations, antibiotic resistance, disruption of gut bacteria, and obesity. Recent research has underscored the importance of collaborative patient-provider communication as a means to reduce the high rates of unnecessary prescriptions for antibiotics. However, most patients and providers do not feel prepared to engage in such challenging conversations. Objectives The aim of this pilot study was to assess the ability of a brief 15-min simulated role-play conversation with virtual humans to serve as a preliminary step to help health care providers and patients practice, and learn how to engage in effective conversations about antibiotics overuse. Methods A total of 69 participants (35 providers and 34 patients) completed the simulation once in one sitting. A pre-post repeated measures design was used to assess changes in patients’ and providers’ self-reported communication behaviors, activation, and preparedness, intention, and confidence to effectively communicate in the patient-provider encounter. Changes in patients’ knowledge and beliefs regarding antibiotic use were also evaluated. Results Patients experienced a short-term positive improvement in beliefs about appropriate antibiotic use for infection (F1,30=14.10, P=.001). Knowledge scores regarding the correct uses of antibiotics improved immediately postsimulation, but decreased at the 1-month follow-up (F1,30=31.16, P.10) Patients with lower levels of activation exhibited positive, short-term benefits in increased intent and confidence to discuss their needs and ask questions in the clinic visit, positive attitudes

  7. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  8. Joint modeling of repeated multivariate cognitive measures and competing risks of dementia and death: a latent process and latent class approach.

    Science.gov (United States)

    Proust-Lima, Cécile; Dartigues, Jean-François; Jacqmin-Gadda, Hélène

    2016-02-10

    Joint models initially dedicated to a single longitudinal marker and a single time-to-event need to be extended to account for the rich longitudinal data of cohort studies. Multiple causes of clinical progression are indeed usually observed, and multiple longitudinal markers are collected when the true latent trait of interest is hard to capture (e.g., quality of life, functional dependency, and cognitive level). These multivariate and longitudinal data also usually have nonstandard distributions (discrete, asymmetric, bounded, etc.). We propose a joint model based on a latent process and latent classes to analyze simultaneously such multiple longitudinal markers of different natures, and multiple causes of progression. A latent process model describes the latent trait of interest and links it to the observed longitudinal outcomes using flexible measurement models adapted to different types of data, and a latent class structure links the longitudinal and cause-specific survival models. The joint model is estimated in the maximum likelihood framework. A score test is developed to evaluate the assumption of conditional independence of the longitudinal markers and each cause of progression given the latent classes. In addition, individual dynamic cumulative incidences of each cause of progression based on the repeated marker data are derived. The methodology is validated in a simulation study and applied on real data about cognitive aging obtained from a large population-based study. The aim is to predict the risk of dementia by accounting for the competing death according to the profiles of semantic memory measured by two asymmetric psychometric tests.

  9. Solving TSP Using Advanced Crossover & Mutating Operators of Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Shruti Sharma

    2013-07-01

    Full Text Available In this paper we develops a new crossover and mutating operator, Round crossover (RX and Round mutating (RM operator, for a genetic algorithm that generates high quality solutions to the Traveling Salesman Problem (TSP. The round crossover operator constructs an offspring from a pair of parents in a circular way using better edges on the basis of their values that may be present in the parents’ structure maintaining the sequence of nodes in the parent chromosomes. The round mutation applied to the resultant chromosome after crossover by selecting a random cut point and then joining the remaining substring to first substring in circular way. The efficiency of the RX is compared as against some existing crossover operators; namely, edge recombination crossover (ERX, Order crossover (OX and partially Matched crossover (PMX for some benchmark TSPLIB instances. Experimental results show that the new crossover operator is better than the PMX, ERX and OX

  10. Kinesio Taping Does Not Alter Quadriceps Isokinetic Strength and Power in Healthy Nonathletic Men: A Prospective Crossover Study

    Directory of Open Access Journals (Sweden)

    Paweł Korman

    2015-01-01

    Full Text Available Objectives. The effects of Kinesio Taping (KT on muscular performance remain largely unclear. This study aimed to investigate the acute effects of KT on the maximum concentric and eccentric quadriceps isokinetic strength. Study Design. This is a single-blinded, placebo crossover, repeated measures study. Methods. Maximum isokinetic concentric/eccentric extension torque, work, and power were assessed by an isokinetic dynamometer without taping (NT and with KT or placebo taping (PT in 17 healthy young men. Repeated measures one-way analysis of variance (ANOVA was used for statistical analyses. Results. Testing concentric contractions at 60°/s or 180°/s isokinetic speed, no significant differences in peak torque (Nm, total work (J, or mean power (W were noted among the application modes under different conditions. Testing eccentric contractions at 30°/s or 60°/s isokinetic speed, no significant differences in mentioned parameters were noted, respectively. KT on the quadriceps neither decreased nor increased muscle strength in the participants. Conclusion. KT application onto the skin overlying the quadriceps muscle does not enhance the strength or power of knee extensors in healthy men.

  11. Crossover versus Stabilometric Platform for the Treatment of Balance Dysfunction in Parkinson's Disease: A Randomized Study.

    Science.gov (United States)

    Frazzitta, G; Bossio, F; Maestri, R; Palamara, G; Bera, R; Ferrazzoli, D

    2015-01-01

    Balance dysfunctions are a major challenge in the treatment of Parkinson's disease (PD). Previous studies have shown that rehabilitation can play a role in their treatment. In this study, we have compared the efficacy of two different devices for balance training: stabilometric platform and crossover. We have enrolled 60 PD patients randomly assigned to two groups. The first one (stabilometric group) performed a 4-week cycle of balance training, using the stabilometric platform, whereas the second one (crossover group) performed a 4-week cycle of balance training, using the crossover. The outcome measures used were Unified Parkinson's Disease Rating Scale (UPDRS) part II, Berg Balance Scale (BBS), Timed Up and Go (TUG), and Six Minutes Walking Test (6MWT). Results showed that TUG, BBS, and UPDRS II improved in both groups. There was not difference in the efficacy of the two balance treatments. Patients in both groups improved also the meters walked in the 6MWT at the end of rehabilitation, but the improvement was better for patients performing crossover training. Our results show that the crossover and the stabilometric platform have the same effect on balance dysfunction of Parkinsonian patients, while crossover gets better results on the walking capacity.

  12. An evaluation of a structured learning program as a component of the clinical practicum in undergraduate nurse education: A repeated measures analysis.

    Science.gov (United States)

    Watt, Elizabeth; Murphy, Maria; MacDonald, Lee; Pascoe, Elizabeth; Storen, Heather; Scanlon, Andrew

    2016-01-01

    There is evidence that nursing students experience stress and anxiety and a reduction in self-efficacy when undertaking clinical placements. Previous reports have identified that a structured three-day program within the Bachelor of Nursing (BN) clinical practicum reduces the students self-report of anxiety and increases self-efficacy. However, it is unreported whether these improved outcomes are sustained for the duration of the clinical placement. The aim of this study was to evaluate the duration of the effect of a three-day structured learning program within the clinical placement on final year Bachelor of Nursing student's report of anxiety and self-efficacy pre- and post-program participation in this intervention and following completion of the clinical practicum. A repeated measures design. University-based Clinical School of Nursing, acute care clinical practicum. Final year Bachelor of Nursing students. The intervention comprised the three-day program on starting the clinical practicum. A questionnaire included the anxiety subscale of The Hospital Anxiety & Depression Scale (The HAD) and the General Self-Efficacy Scale (GSES-12). The questionnaire was completed on day one (time one), upon completion of the three-day program (time two) and upon completion of placement on day 18 (time three). The questionnaire response rate varied over time. There was a statistically significant effect in reducing anxiety over time: F(1.73,74.46)=25.20, plearning program and the benefit of the intervention is sustained for the clinical placement duration. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Which are the most useful scales for predicting repeat self-harm? A systematic review evaluating risk scales using measures of diagnostic accuracy

    Science.gov (United States)

    Quinlivan, L; Cooper, J; Davies, L; Hawton, K; Gunnell, D; Kapur, N

    2016-01-01

    Objectives The aims of this review were to calculate the diagnostic accuracy statistics of risk scales following self-harm and consider which might be the most useful scales in clinical practice. Design Systematic review. Methods We based our search terms on those used in the systematic reviews carried out for the National Institute for Health and Care Excellence self-harm guidelines (2012) and evidence update (2013), and updated the searches through to February 2015 (CINAHL, EMBASE, MEDLINE, and PsychINFO). Methodological quality was assessed and three reviewers extracted data independently. We limited our analysis to cohort studies in adults using the outcome of repeat self-harm or attempted suicide. We calculated diagnostic accuracy statistics including measures of global accuracy. Statistical pooling was not possible due to heterogeneity. Results The eight papers included in the final analysis varied widely according to methodological quality and the content of scales employed. Overall, sensitivity of scales ranged from 6% (95% CI 5% to 6%) to 97% (CI 95% 94% to 98%). The positive predictive value (PPV) ranged from 5% (95% CI 3% to 9%) to 84% (95% CI 80% to 87%). The diagnostic OR ranged from 1.01 (95% CI 0.434 to 2.5) to 16.3 (95%CI 12.5 to 21.4). Scales with high sensitivity tended to have low PPVs. Conclusions It is difficult to be certain which, if any, are the most useful scales for self-harm risk assessment. No scales perform sufficiently well so as to be recommended for routine clinical use. Further robust prospective studies are warranted to evaluate risk scales following an episode of self-harm. Diagnostic accuracy statistics should be considered in relation to the specific service needs, and scales should only be used as an adjunct to assessment. PMID:26873046

  14. Enhanced kangaroo mother care for heel lance in preterm neonates: a crossover trial.

    Science.gov (United States)

    Johnston, C C; Filion, F; Campbell-Yeo, M; Goulet, C; Bell, L; McNaughton, K; Byron, J

    2009-01-01

    To test if enhancing maternal skin-to-skin contact, or kangaroo mother care (KMC) by adding rocking, singing and sucking is more efficacious than simple KMC for procedural pain in preterm neonates. Preterm neonates (n=90) between 32 0/7 and 36 0/7 weeks' gestational age participated in a single-blind randomized crossover design. The infant was held in KMC with the addition of rocking, singing and sucking or the infant was held in KMC without additional stimulation. The Premature Infant Pain Profile was the primary outcome with time to recover as the secondary outcome. A repeated-measures analysis of covariance was employed for analyses. There were no significant differences in any of the 30 s time periods over the 2 min of blood sampling nor in time to return to baseline. Compared to historical controls of the same age in incubator, the pain scores were lower and comparable to other studies of KMC. There were site differences related to lower scores with the use of sucrose in one site and higher scores in younger, sicker infants in another site. The sensorial stimulations from skin-to-skin contact that include tactile, olfactory sensations from the mother are sufficient to decrease pain response in premature neonates. Other studies showing that rocking, sucking and music were efficacious were independent of skin-to-skin contact, which, when used alone has been shown to be effective as reported across studies.

  15. Synthetic food colourings and 'hyperactivity': a double-blind crossover study.

    Science.gov (United States)

    Rowe, K S

    1988-04-01

    Of 220 children referred for suspected 'hyperactivity', 55 were subjected to a 6 week trial of the Feingold diet. Forty (72.7%) demonstrated improved behaviour and 26 (47.3%) remained improved following liberalization of the diet over a period of 3-6 months. The parents of 14 children claimed that a particular cluster of behaviours was associated with the ingestion of foods containing synthetic colourings. A double-blind crossover study, employing a single-subject repeated measures design was conducted, using eight of these children. Subjects were maintained on a diet free from synthetic additives and were challenged daily for 18 weeks with either placebo (during lead-in and washout periods) or 50 mg of either tartrazine or carmoisine, each for 2 separate weeks. Two significant reactors were identified whose behavioural pattern featured extreme irritability, restlessness and sleep disturbance. One of the reactors did not have inattention as a feature. The findings raise the issue of whether the strict criteria for inclusion in studies concerned with 'hyperactivity' based on 'attention deficit disorder' may miss children who indicate behavioural changes associated with the ingestion of food colourings. Moreover, for further studies, the need to construct a behavioural rating instrument specifically validated for dye challenge is suggested.

  16. Kinesiology tape does not promote vertical jumping performance: A deceptive crossover trial.

    Science.gov (United States)

    Cheung, R T H; Yau, Q K C; Wong, K; Lau, P; So, A; Chan, N; Kwok, C; Poon, K Y; Yung, P S H

    2016-02-01

    Kinesiology tape (KINTAPE) is one of the most common adhesive therapeutic tapes. Apart from clinical applications, KINTAPE claims to be able to enhance functional performance by muscle activity facilitation. However, emerging evidence suggests that the isokinetic muscle strength remains similar when the placebo effect is eliminated. In view of the weak relationship between functional performance and isokinetic muscle strength, this study investigated the true effects of KINTAPE on functional performance. Deceptive, randomized, and crossover trial. Sixty four experienced volleyball players performed vertical jumping test under three taping conditions: true facilitative KINTAPE, sham KINTAPE, and no KINTAPE. Under the pretense of applying adhesive muscle sensors, KINTAPE was applied to their quadriceps and gastrocnemius in the first two conditions. Mean maximum jump height and peak jump power were averaged from three attempts. Within-subject comparisons were conducted by repeated measure ANOVA. Out of 64 participants, 30 of them were successfully deceived and they were ignorant about KINTAPE. No significant differences were found in both maximum jump height (η(2) = 0.001; p = 0.241) and peak jump power (η(2) = 0.001; p = 0.134) between three taping conditions. The results showed that KINTAPE did not facilitate muscle performance by generating higher jumping power or yielding a better jumping performance. These findings reinforce that previously reported muscle facilitatory effects or functional enhancement using KINTAPE may be attributed to placebo effects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Bloom Syndrome Helicase Promotes Meiotic Crossover Patterning and Homolog Disjunction.

    Science.gov (United States)

    Hatkevich, Talia; Kohl, Kathryn P; McMahan, Susan; Hartmann, Michaelyn A; Williams, Andrew M; Sekelsky, Jeff

    2017-01-09

    In most sexually reproducing organisms, crossover formation between homologous chromosomes is necessary for proper chromosome disjunction during meiosis I. During meiotic recombination, a subset of programmed DNA double-strand breaks (DSBs) are repaired as crossovers, with the remainder becoming noncrossovers [1]. Whether a repair intermediate is designated to become a crossover is a highly regulated decision that integrates several crossover patterning processes, both along chromosome arms (interference and the centromere effect) and between chromosomes (crossover assurance) [2]. Because the mechanisms that generate crossover patterning have remained elusive for over a century, it has been difficult to assess the relationship between crossover patterning and meiotic chromosome behavior. We show here that meiotic crossover patterning is lost in Drosophila melanogaster mutants that lack the Bloom syndrome helicase. In the absence of interference and the centromere effect, crossovers are distributed more uniformly along chromosomes. Crossovers even occur on the small chromosome 4, which normally never has meiotic crossovers [3]. Regulated distribution of crossovers between chromosome pairs is also lost, resulting in an elevated frequency of homologs that do not receive a crossover, which in turn leads to elevated nondisjunction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Iron(III) spin crossover compounds

    NARCIS (Netherlands)

    van Koningsbruggen, PJ; Maeda, Y; Oshio, H

    2004-01-01

    In this chapter, selected results obtained so far on Fe(III) spin crossover compounds are summarized and discussed. Fe(III) spin transition materials of ligands containing chalcogen donor atoms are considered with emphasis on those of N,N-disubstituted-dithiocarbamates, N,N-disubstituted-XY-carbamat

  19. The Design of Cluster Randomized Crossover Trials

    Science.gov (United States)

    Rietbergen, Charlotte; Moerbeek, Mirjam

    2011-01-01

    The inefficiency induced by between-cluster variation in cluster randomized (CR) trials can be reduced by implementing a crossover (CO) design. In a simple CO trial, each subject receives each treatment in random order. A powerful characteristic of this design is that each subject serves as its own control. In a CR CO trial, clusters of subjects…

  20. The design of cluster randomized crossover trials

    NARCIS (Netherlands)

    Rietbergen, C.; Moerbeek, M.

    2011-01-01

    The inefficiency induced by between-cluster variation in cluster randomized (CR) trials can be reduced by implementing a crossover (CO) design. In a simple CO trial, each subject receives each treatment in random order. A powerful characteristic of this design is that each subject serves as its own

  1. Arabidopsis meiotic crossover hotspots overlap with H2A.Z nucleosomes at gene promoters

    Science.gov (United States)

    Choi, Kyuha; Zhao, Xiaohui; Kelly, Krystyna A.; Venn, Oliver; Higgins, James D.; Yelina, Nataliya E.; Hardcastle, Thomas J.; Ziolkowski, Piotr A.; Copenhaver, Gregory P.; Franklin, F. Chris H.; McVean, Gil; Henderson, Ian R.

    2013-01-01

    PRDM9 directs human meiotic crossover hotspots to intergenic sequence motifs, whereas budding yeast hotspots overlap low nucleosome density regions in gene promoters. To investigate hotspots in plants, which lack PRDM9, we used coalescent analysis of Arabidopsis genetic variation. Crossovers increase towards gene promoters and terminators, and hotspots are associated with active chromatin modifications, including H2A.Z, histone H3K4me3, low nucleosome density and low DNA methylation. Hotspot-enriched A-rich and CTT-repeat DNA motifs occur upstream and downstream of transcriptional start respectively. Crossovers are asymmetric around promoters and highest over CTT-motifs and H2A.Z-nucleosomes. Pollen-typing, segregation and cytogenetic analysis show decreased crossovers in the arp6 H2A.Z deposition mutant, at multiple scales. During meiosis H2A.Z and DMC1/RAD51 recombinases form overlapping chromosomal foci. As arp6 reduces DMC1/RAD51 foci, H2A.Z may promote formation or processing of meiotic DNA double-strand breaks. We propose that gene chromatin ancestrally designates hotspots within eukaryotes and PRDM9 is a derived state within vertebrates. PMID:24056716

  2. Alterations in cardiovascular function by particulate matter in rats using a crossover design.

    Science.gov (United States)

    Chuang, Hsiao-Chi; Lin, Yin-Jyun; Chou, Charles C K; Hwang, Jing-Shiang; Chen, Chu-Chih; Yan, Yuan-Horng; Hsieh, Hui-I; Chuang, Kai-Jen; Cheng, Tsun-Jen

    2017-08-31

    The objective of this study was to investigate associations between cardiovascular effects and urban ambient particle constituents using an in vivo crossover experimental design. Ambient particles were introduced to an exposure chamber for whole-body exposure of WKY rats, where the particulate matter with an aerodynamic diameter of PM2.5) mass concentration, particle number concentration, and black carbon (BC) were monitored. Organic carbon (OC), elemental carbon (EC), and soluble ions of PM2.5 were determined. In a crossover design, rats were exposed to ambient particles or high-efficiency particle arrestance (HEPA)-filtered control air for 7 days following a 7-day washout interval. The crossover exposure between particles and HEPA-filtered air was repeated 4 times. Radiotelemetric data on blood pressure (BP) [systolic BP (SBP), diastolic BP (DBP), pulse pressure (PP), and mean arterial pressure (MAP)], heart rate (HR), and heart rate viability (HRV) were subsequently obtained during the entire study. Exposure to the PM2.5 mass concentration was associated with decreases in the SBP, DBP, MAP, and HR (p PM2.5 mass concentration (p +), Cl(-), and NO3(-). Cl(-) was associated with the DBP, MAP, HR, SDNN, and RMSSD. NO3(-) was correlated with the SBP, MAP, HR, SDNN, and RMSSD. In conclusion, we observed cardiovascular responses to ambient particles in vivo using a crossover design which can reduce animal use in future environmental studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Critical Crossover Functions for Simple Fluids: Towards the Crossover Modelling Uniqueness

    Science.gov (United States)

    Garrabos, Yves; Lecoutre, Carole; Marre, Samuel; LeNeindre, Bernard; Hahn, Inseob

    2016-11-01

    Based on a single non-universal temperature scaling factor present in a simple fluid case, a detailed analysis of non-universal parameters involved in different critical-to-classical crossover models is given. For the infinite limit of the cutoff wave number, a set of three scaling-parameters is defined for each model such that it shows all the shapes of the theoretical crossover functions overlap on the mean crossover function shapes close to the non-trivial fixed point. The analysis of corresponding links between their fluid-dependent parameters opens a route to define a parametric model of crossover equation-of-state, closely satisfying the universal features calculated from the Ising-like limit in the massive renormalization scheme.

  4. ATM promotes the obligate XY crossover and both crossover control and chromosome axis integrity on autosomes.

    Directory of Open Access Journals (Sweden)

    Marco Barchi

    2008-05-01

    Full Text Available During meiosis in most sexually reproducing organisms, recombination forms crossovers between homologous maternal and paternal chromosomes and thereby promotes proper chromosome segregation at the first meiotic division. The number and distribution of crossovers are tightly controlled, but the factors that contribute to this control are poorly understood in most organisms, including mammals. Here we provide evidence that the ATM kinase or protein is essential for proper crossover formation in mouse spermatocytes. ATM deficiency causes multiple phenotypes in humans and mice, including gonadal atrophy. Mouse Atm-/- spermatocytes undergo apoptosis at mid-prophase of meiosis I, but Atm(-/- meiotic phenotypes are partially rescued by Spo11 heterozygosity, such that ATM-deficient spermatocytes progress to meiotic metaphase I. Strikingly, Spo11+/-Atm-/- spermatocytes are defective in forming the obligate crossover on the sex chromosomes, even though the XY pair is usually incorporated in a sex body and is transcriptionally inactivated as in normal spermatocytes. The XY crossover defect correlates with the appearance of lagging chromosomes at metaphase I, which may trigger the extensive metaphase apoptosis that is observed in these cells. In addition, control of the number and distribution of crossovers on autosomes appears to be defective in the absence of ATM because there is an increase in the total number of MLH1 foci, which mark the sites of eventual crossover formation, and because interference between MLH1 foci is perturbed. The axes of autosomes exhibit structural defects that correlate with the positions of ongoing recombination. Together, these findings indicate that ATM plays a role in both crossover control and chromosome axis integrity and further suggests that ATM is important for coordinating these features of meiotic chromosome dynamics.

  5. Association of Repeatedly Measured High-Sensitivity-Assayed Troponin I with Cardiovascular Disease Events in a General Population from the MORGAM/BiomarCaRE Study

    DEFF Research Database (Denmark)

    Hughes, Maria F; Ojeda, Francisco; Saarela, Olli;

    2017-01-01

    BACKGROUND: High-sensitivity troponin I (hs-cTnI) concentrations reflect myocardial stress. The role of hs-cTnI in predicting long-term changes in the risk of cardiovascular disease (CVD) in general populations is not clearly defined. METHODS: We investigated whether the change in 3 repeated meas...

  6. Repeated electromagnetic induction measurements for mapping soil moisture at the field scale: comparison with data from a wireless soil moisture monitoring network

    Science.gov (United States)

    Martini, Edoardo; Werban, Ulrike; Zacharias, Steffen; Pohle, Marco; Dietrich, Peter; Wollschläger, Ute

    2016-04-01

    Electromagnetic induction (EMI) methods are widely used for soil mapping, as they allow fast and relatively low-cost surveys of soil apparent electrical conductivity (ECa) at various scales. Soil ECa is well known to be influenced by both the volumetric content and the electrical conductivity (EC) of soil water, as well as by soil temperature and by the volume of the solid particles and their EC. Among other applications, EMI has become widely used to determine soil water content or to study hydrological processes within the field of hydrogeophysics. Although the use of non-invasive EMI for imaging soil spatial properties is very attractive, the dependence of ECa on several properties and states challenges any interpretation with respect to individual soil properties or states such as θ. The major aim of this study was to further investigate the potential of repeated EMI measurements to map soil moisture at the hillslope scale, with particular focus on the temporal variability of the spatial patterns of ECa and soil moisture, respectively, and on the stability of the ECa-soil moisture relationship over time. To this end, we compared time series of EMI measurements with high-resolution soil moisture data for a non-intensively managed hillslope area in the Schäfertal catchment (Central Germany) for which the spatial distribution of soil properties and soil water dynamics were known in detail. Soil water and temperature dynamics were observed in 40 soil profiles at hourly resolution during 14 months using a wireless monitoring network. During this period of time, ECa was mapped on seven occasions using an EM38-DD device. For the investigated site, ECa showed small temporal variations (ranging between 0 and 24 mS/m) whereas the temporal range of soil moisture was very large (from very dry to soil saturation). Furthermore, temporal changes of the spatial pattern of ECa differed from temporal changes of the spatial pattern of soil moisture. The ECa-soil moisture

  7. The crossover from mean-field to 3D-Ising critical behaviour in a 3-component microemulsion

    DEFF Research Database (Denmark)

    Seto, H.; Schwahn, D.; Yokoi, E.

    1995-01-01

    Density fluctuations and associated critical phenomena of water droplets in a water-in-oil microemulsion system have been studied, We have recently found a mean-field behavior in the ''near-critical region'', and this evidence suggested that a crossover from mean-field to non-mean-field behavior...... should be observed. Therefore, a measurement of small-angle neutron scattering was carried out at JAERI with more precise temperature steps. Indeed, the crossover from mean-held to 3D-Ising behavior was observed, and the result could be interpreted by the asymptotic crossover theory proposed by Belyakov...

  8. Delay in the Detrended Fluctuation Analysis Crossover Point as a Risk Factor for Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Manuel Varela

    2016-01-01

    Full Text Available Detrended Fluctuation Analysis (DFA measures the complexity of a glucose time series obtained by means of a Continuous Glucose Monitoring System (CGMS and has proven to be a sensitive marker of glucoregulatory dysfunction. Furthermore, some authors have observed a crossover point in the DFA, signalling a change of dynamics, arguably dependent on the beta-insular function. We investigate whether the characteristics of this crossover point have any influence on the risk of developing type 2 diabetes mellitus (T2DM. To this end we recruited 206 patients at increased risk of T2DM (because of obesity, essential hypertension, or a first-degree relative with T2DM. A CGMS time series was obtained, from which the DFA and the crossover point were calculated. Patients were then followed up every 6 months for a mean of 17.5 months, controlling for the appearance of T2DM diagnostic criteria. The time to crossover point was a significant predictor risk of developing T2DM, even after adjusting for other variables. The angle of the crossover was not predictive by itself but became significantly protective when the model also considered the crossover point. In summary, both a delay and a blunting of the crossover point predict the development of T2DM.

  9. Delay in the Detrended Fluctuation Analysis Crossover Point as a Risk Factor for Type 2 Diabetes Mellitus

    Science.gov (United States)

    Varela, Manuel; Vigil, Luis; Rodriguez, Carmen; Vargas, Borja; García-Carretero, Rafael

    2016-01-01

    Detrended Fluctuation Analysis (DFA) measures the complexity of a glucose time series obtained by means of a Continuous Glucose Monitoring System (CGMS) and has proven to be a sensitive marker of glucoregulatory dysfunction. Furthermore, some authors have observed a crossover point in the DFA, signalling a change of dynamics, arguably dependent on the beta-insular function. We investigate whether the characteristics of this crossover point have any influence on the risk of developing type 2 diabetes mellitus (T2DM). To this end we recruited 206 patients at increased risk of T2DM (because of obesity, essential hypertension, or a first-degree relative with T2DM). A CGMS time series was obtained, from which the DFA and the crossover point were calculated. Patients were then followed up every 6 months for a mean of 17.5 months, controlling for the appearance of T2DM diagnostic criteria. The time to crossover point was a significant predictor risk of developing T2DM, even after adjusting for other variables. The angle of the crossover was not predictive by itself but became significantly protective when the model also considered the crossover point. In summary, both a delay and a blunting of the crossover point predict the development of T2DM. PMID:27294154

  10. Quantum-classical crossover in electrodynamics

    CERN Document Server

    Polonyi, J

    2006-01-01

    A classical field theory is proposed for the electric current and the electromagnetic field interpolating between microscopic and macroscopic domains. It represents a generalization of the density functional for the dynamics of the current and the electromagnetic field in the quantum side of the crossover and reproduces standard classical electrodynamics on the other side. The effective action derived in the closed time path formalism and the equations of motion follow from the variational principle. The polarization of the Dirac-see can be taken into account in the quadratic approximation of the action by the introduction of the deplacement field strengths as in conventional classical electrodynamics. Decoherence appears naturally as a simple one-loop effect in this formalism. It is argued that the radiation time arrow is generated from the quantum boundary conditions in time by decoherence at the quantum-classical crossover and the Abraham-Lorentz force arises from the accelerating charge or from other char...

  11. Exchangeability in the case-crossover design.

    Science.gov (United States)

    Mittleman, Murray A; Mostofsky, Elizabeth

    2014-10-01

    In cohort and case-control studies, confounding that arises as a result of differences in the distribution of determinants of the outcome between exposure groups leading to non-exchangeability are addressed by restriction, matching or with statistical models. In case-only studies, this issue is addressed by comparing each individual with his/herself. Although case-only designs use self-matching and only include individuals who develop the outcome of interest, issues of non-exchangeability are identical to those that arise in traditional case-control and cohort studies. In this review, we describe one type of case-only design, the case-crossover design, and discuss how the concept of exchangeability can be used to understand issues of confounding, carryover effects, period effects and selection bias in case-crossover studies.

  12. Het dilemma van een verleidelijk crossover boek

    Directory of Open Access Journals (Sweden)

    A. Schuurman

    2008-01-01

    Full Text Available Woud, A. van der, Een nieuwe wereld. Het ontstaan van het moderne Nederland (Amsterdam 2006The Predicament of a Seductive Crossover BookAuke van der Woud’s new book is a must for everyone interested in the second half of the nineteenth century, particularly the consequences of spatial change. His book has all the virtues and vices of a crossover book, that is one which appeals to two different audiences. It is a book based on new research written for the general reader. Therefore, it is not clear enough with regard to various scientific questions. More explicit attention for the role of industrial capitalism and the process of democracy would have enriched the book even more.

  13. A Mathematical Unification of Geometric Crossovers Defined on Phenotype Space

    CERN Document Server

    Yoon, Yourim; Moraglio, Alberto; Moon, Byung-Ro

    2009-01-01

    Geometric crossover is a representation-independent definition of crossover based on the distance of the search space interpreted as a metric space. It generalizes the traditional crossover for binary strings and other important recombination operators for the most frequently used representations. Using a distance tailored to the problem at hand, the abstract definition of crossover can be used to design new problem specific crossovers that embed problem knowledge in the search. This paper is motivated by the fact that genotype-phenotype mapping can be theoretically interpreted using the concept of quotient space in mathematics. In this paper, we study a metric transformation, the quotient metric space, that gives rise to the notion of quotient geometric crossover. This turns out to be a very versatile notion. We give many example applications of the quotient geometric crossover.

  14. Optimal crossover designs for the proportional model

    OpenAIRE

    Zheng, Wei

    2013-01-01

    In crossover design experiments, the proportional model, where the carryover effects are proportional to their direct treatment effects, has draw attentions in recent years. We discover that the universally optimal design under the traditional model is E-optimal design under the proportional model. Moreover, we establish equivalence theorems of Kiefer-Wolfowitz's type for four popular optimality criteria, namely A, D, E and T (trace).

  15. Experimental evidence for a dimensional crossover of the vortex ensemble in BSCCO (Bi{sub 1.8}Pb{sub 0.4}Sr{sub 1.8}Ba{sub 0.2}Ca{sub 2}Cu{sub 3}O{sub x}) by multi-harmonic ac susceptibility measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mihalache, V. [National Institute of Materials Physics, Atomistilor 105 bis, Judet Ilfov, P.O. Box MG 7, 077125 Magurele (Romania)]. E-mail: vmihal@infim.ro; Popa, S. [National Institute of Materials Physics, Atomistilor 105 bis, Judet Ilfov, P.O. Box MG 7, 077125 Magurele (Romania); Di Gioacchino, D. [INFN-LNF, Via E. Fermi 40, 00044 Frascati (Italy); Tripodi, P. [INFN-LNF, Via E. Fermi 40, 00044 Frascati (Italy); H.E.R.A., Corso della Repubblica 448, 00049 Velletri (Italy); Vinko, J.D. [H.E.R.A., Corso della Repubblica 448, 00049 Velletri (Italy)

    2006-01-01

    We have studied a portion of H-T phase diagram of the anisotropic Bi2223 bulk system using multi-harmonic ac susceptibility measurements ({chi}{sub n}). Based on the behavior of the third harmonic modulus, {chi}{sub 3}, the irreversibility line (IL) was obtained from the onset of {chi}{sub 3} and an anomalous peak effect (PE) was observed. It has been shown that the anomalous peak is due to the crossover between a three-dimensional (3D) and a quasi-two dimensional (quasi-2D) peculiarity of vortex dynamics, the crossover magnetic field being H{sub cr}{approx}0.1T. The obtained portion of B{sub irr}(T) is well described by the melting line of the flux lattice. The 3D flux fluctuation part (low field and high temperature) is described by the nearly parabolic temperature dependence B=B{sub 0}(T{sub c}/T-1){sup n} with n=1.58 (sample 1) and n=1.48 (sample 2). The other region (high field and low temperature) is well described by the temperature dependence of the quasi-2D flux fluctuations, T{sub m}(H)=T{sub m}{sup 2D}[1+b/(lnB/B{sub cr}){sup 1/{nu}}] corresponding to the weak interaction between pancake vortices from adjacent planes. The 2D limit temperature was determined as T{sub m}{sup 2D}=36.7K (sample 1) and T{sub m}{sup 2D}=27.3K (sample 2)

  16. Dynamical Landau theory of the glass crossover

    Science.gov (United States)

    Rizzo, Tommaso

    2016-07-01

    I introduce a dynamical field theory to describe the glassy behavior in supercooled liquids. The mean-field approximation of the theory predicts a dynamical arrest transition, as in the ideal mode-coupling theory and mean-field discontinuous spin-glass models. Instead, beyond the mean-field approximation, the theory predicts that the transition is avoided and transformed into a crossover, as observed in experiments and simulations. To go beyond mean-field, a standard perturbative loop expansion is performed at first. Approaching the ideal critical point this expansion is divergent at all orders and I show that the leading divergent term at any given order is the same as a dynamical stochastic equation, called stochastic-beta relaxation (SBR) in Europhys. Lett. 106, 56003 (2014), 10.1209/0295-5075/106/56003. At variance with the original theory, SBR can be studied beyond mean-field directly, without the need to resort to a perturbative expansion. Thus it provides a qualitative and quantitative description of the dynamical crossover. For consistency reasons, it is important to establish the connection between the dynamical field theory and SBR beyond perturbation theory. This can be done with the help of a stronger result: the dynamical field theory is exactly equivalent to a theory with quenched disorder. Qualitatively, the nonperturbative mechanism leading to the crossover is therefore the same as the mechanism of SBR. Quantitatively, SBR is equivalent to making the mean-field approximation once the quenched disorder has been generated.

  17. Constructing higher order DNA origami arrays using DNA junctions of anti-parallel/parallel double crossovers

    Science.gov (United States)

    Ma, Zhipeng; Park, Seongsu; Yamashita, Naoki; Kawai, Kentaro; Hirai, Yoshikazu; Tsuchiya, Toshiyuki; Tabata, Osamu

    2016-06-01

    DNA origami provides a versatile method for the construction of nanostructures with defined shape, size and other properties; such nanostructures may enable a hierarchical assembly of large scale architecture for the placement of other nanomaterials with atomic precision. However, the effective use of these higher order structures as functional components depends on knowledge of their assembly behavior and mechanical properties. This paper demonstrates construction of higher order DNA origami arrays with controlled orientations based on the formation of two types of DNA junctions: anti-parallel and parallel double crossovers. A two-step assembly process, in which preformed rectangular DNA origami monomer structures themselves undergo further self-assembly to form numerically unlimited arrays, was investigated to reveal the influences of assembly parameters. AFM observations showed that when parallel double crossover DNA junctions are used, the assembly of DNA origami arrays occurs with fewer monomers than for structures formed using anti-parallel double crossovers, given the same assembly parameters, indicating that the configuration of parallel double crossovers is not energetically preferred. However, the direct measurement by AFM force-controlled mapping shows that both DNA junctions of anti-parallel and parallel double crossovers have homogeneous mechanical stability with any part of DNA origami.

  18. Anode reaction mechanism and crossover in direct dimethyl ether fuel cell

    Science.gov (United States)

    Mizutani, Itsuko; Liu, Yan; Mitsushima, Shigenori; Ota, Ken-ichiro; Kamiya, Nobuyuki

    The anode reaction mechanism and the crossover of a direct dimethyl ether fuel cell (DDMEFC) have been investigated. This was done by considering the anode products of the half-cell and DDMEFC experiments. It was found that the CO 2 current efficiency of the DDMEFC was almost 1 at 30-80 °C and that this value was higher than that of a DMFC. The main by-products of the DDMEFC were methyl formate and methanol whose amounts are negligibly small compared to CO 2. With respect to crossover, the influence of DME on the oxygen reduction reaction (ORR) was examined with a half-cell, and the amount of crossover of DME was measured while operating an actually constructed DDMEFC. From these experiments, it was found that DME does not influence the ORR as much as methanol under similar conditions. Furthermore, the amount of crossover of DME decreased with an increase in temperature and current density and it was one-half that of methanol on open circuit and at 80 °C. The CO 2 current efficiency of the DDMEFC is higher than that of a DMFC, and the influence of crossover in the DDMEFC is less than that in the DMFC. Since the temperature dependence of the reactivity of DME is larger than that of methanol, the higher output is expected for the DDMEFC at the elevated temperature. Therefore, the DDMEFC has a promising potential as a portable power source in the future.

  19. Threshold Levels of Infant and Under-Five Mortality for Crossover between Life Expectancies at Ages Zero, One and Five in India: A Decomposition Analysis.

    Directory of Open Access Journals (Sweden)

    Manisha Dubey

    Full Text Available Under the prevailing conditions of imbalanced life table and historic gender discrimination in India, our study examines crossover between life expectancies at ages zero, one and five years for India and quantifies the relative share of infant and under-five mortality towards this crossover.We estimate threshold levels of infant and under-five mortality required for crossover using age specific death rates during 1981-2009 for 16 Indian states by sex (comprising of India's 90% population in 2011. Kitagawa decomposition equations were used to analyse relative share of infant and under-five mortality towards crossover.India experienced crossover between life expectancies at ages zero and five in 2004 for menand in 2009 for women; eleven and nine Indian states have experienced this crossover for men and women, respectively. Men usually experienced crossover four years earlier than the women. Improvements in mortality below ages five have mostly contributed towards this crossover. Life expectancy at age one exceeds that at age zero for both men and women in India except for Kerala (the only state to experience this crossover in 2000 for men and 1999 for women.For India, using life expectancy at age zero and under-five mortality rate together may be more meaningful to measure overall health of its people until the crossover. Delayed crossover for women, despite higher life expectancy at birth than for men reiterates that Indian women are still disadvantaged and hence use of life expectancies at ages zero, one and five become important for India. Greater programmatic efforts to control leading causes of death during the first month and 1-59 months in high child mortality areas can help India to attain this crossover early.

  20. Critical velocity in the BEC-BCS crossover.

    Science.gov (United States)

    Weimer, Wolf; Morgener, Kai; Singh, Vijay Pal; Siegl, Jonas; Hueck, Klaus; Luick, Niclas; Mathey, Ludwig; Moritz, Henning

    2015-03-01

    We map out the critical velocity in the crossover from Bose-Einstein condensation to Bardeen-Cooper-Schrieffer superfluidity with ultracold ^{6}Li gases. A small attractive potential is dragged along lines of constant column density. The rate of the induced heating increases steeply above a critical velocity v_{c}. In the same samples, we measure the speed of sound v_{s} by exciting density waves and compare the results to the measured values of v_{c}. We perform numerical simulations in the Bose-Einstein condensation regime and find very good agreement, validating the approach. In the strongly correlated regime our measurements of v_{c} provide a testing ground for theoretical approaches.

  1. Quantum repeated games revisited

    CERN Document Server

    Frackiewicz, Piotr

    2011-01-01

    We present a scheme for playing quantum repeated 2x2 games based on the Marinatto and Weber's approach to quantum games. As a potential application, we study twice repeated Prisoner's Dilemma game. We show that results not available in classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games.

  2. Correlation length and universality in the BCS-BEC crossover for energy-dependent resonance superfluidity

    Science.gov (United States)

    Musolino, S.; Chiofalo, M.-L.

    2017-07-01

    We consider the BCS-BEC crossover of a quantum Fermi gas at T = 0 in the presence of an energy-dependent Fano-Feshbach resonance, driving the system from broad to narrow limits. We choose a minimal microscopic potential reproducing the two-particle resonance physics in terms of the scattering length a and the effective range R∗ representing the resonance width, and solve the BCS mean-field equations varying a, R∗ and the density. We show that the condensate fraction manifests a universal behavior when the correlation length, measuring the pair size, is used as the crossover parameter. Generally, a negative effective range has the effect of stretching the crossover region between the two extreme regimes, as evidenced by the behavior of the chemical potential. These results can be useful in view of the more recent perspectives of realizing narrow resonances also by optical means and amenable as a base quantum Monte Carlo simulations.

  3. The Crossover between Life Expectancies at Birth and at Age One

    DEFF Research Database (Denmark)

    Canudas-Romo, Vladimir; Becker, S

    2011-01-01

    The single most used demographic measure to describe population health is life expectancy at birth, but life expectancies at ages other than zero are also used in the study of human longevity. Our intuition tells us that the longest life expectancy is that of a newborn. However, historically......, the expectation of life at age one (e1) has exceeded the expectation of life at birth (e0). The crossover between e0 and e1 only occurred in the developed world in the second half of the twentieth century. Life tables for populations that have not achieved this crossing between life expectancy at birth and at age...... one are referred to here as imbalanced. This crossover occurs when infant mortality is equal to the inverse of life expectancy at age one. This simple relation between mortality at age zero and mortality after age one divides the world into countries that have achieved the crossover in life...

  4. Acute changes of hip joint range of motion using selected clinical stretching procedures: A randomized crossover study.

    Science.gov (United States)

    Hammer, Adam M; Hammer, Roger L; Lomond, Karen V; O'Connor, Paul

    2017-09-01

    Hip adductor flexibility and strength is an important component of athletic performance and many activities of daily living. Little research has been done on the acute effects of a single session of stretching on hip abduction range of motion (ROM). The aim of this study was to compare 3 clinical stretching procedures against passive static stretching and control on ROM and peak isometric maximal voluntary contraction (MVC). Using a randomized crossover study design, a total of 40 participants (20 male and 20 female) who had reduced hip adductor muscle length attended a familiarization session and 5 testing sessions on non-consecutive days. Following the warm-up and pre-intervention measures of ROM and MVC, participants were randomly assigned 1 of 3 clinical stretching procedures (modified lunge, multidirectional, and joint mobilization) or a static stretch or control condition. Post-intervention measures of ROM and MVC were taken immediately following completion of the assigned condition. An ANOVA using a repeated measure design with the change score was conducted. All interventions resulted in small but statistically significant (p stretching was greater than control (p = 0.031). These data suggest that a single session of stretching has only a minimal effect on acute changes of hip abduction ROM. Although hip abduction is a frontal plane motion, to effectively increase the extensibility of the structures that limit abduction, integrating multi-planar stretches may be indicated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Estimation of hydrogen crossover through Nafion {sup registered} membranes in PEMFCs

    Energy Technology Data Exchange (ETDEWEB)

    Francia, Carlotta; Ijeri, Vijaykumar S.; Specchia, Stefania; Spinelli, Paolo [Department of Materials Science and Chemical Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)

    2011-02-15

    It is well known that the membrane electrode assembly (MEA) of proton exchange membrane fuel cells (PEMFCs) can undergo deterioration, during long term operation, of both the electrode materials and the membrane. Hydrogen crossover, i.e., the undesired diffusion of the gas from the anode to the cathode through the membrane, has been ascribed as one of the main causes of deterioration of perfluorinated ionomer membranes, normally employed in PEMFCs. One of the effects of the hydrogen permeation across the membrane is the decrease of the cell's open circuit voltage (OCV), due to the reaction between the fuel and the oxidant at the cathode surface. Such reaction can lead to the production of peroxide radicals, causing the degradation of both the PEM and the catalyst layer. Hydrogen crossover increases when temperature, pressure and humidity of the cell rise. The hydrogen permeation rate through a very thin PEM is typically lower than 1 mA cm{sup -2} for a new MEA, but it can exceed 10-20 mA cm{sup -2} after long term operation. Various methods have been proposed to measure the rate of hydrogen crossover, mainly based on electrochemical tests on a single FC with a flow of nitrogen at the cathode, so that the steady state current corresponds to the oxidation of crossed hydrogen. Hydrogen crossover has been also determined indirectly by assuming that the changes in the OCV values are due to the passage of fuel from the anode to the cathode. In this paper, a simplified mathematical model for the direct determination of hydrogen crossover permeation rate is presented. Such a model is based on analytical expressions of the polarization terms and it is employed to determine the hydrogen crossover rate. The main results show that the hydrogen crossover current densities increased from 0.12 to 0.32 mA cm{sup -2}, by decreasing the thickness of the membranes and increasing the operating cell temperature. Moreover, the hydrogen crossover determined for a fresh MEA was

  6. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  7. Dimensional BCS-BEC crossover in ultracold Fermi gases

    Energy Technology Data Exchange (ETDEWEB)

    Boettcher, Igor

    2014-12-10

    We investigate thermodynamics and phase structure of ultracold Fermi gases, which can be realized and measured in the laboratory with modern trapping techniques. We approach the subject from a both theoretical and experimental perspective. Central to the analysis is the systematic comparison of the BCS-BEC crossover of two-component fermions in both three and two dimensions. A dimensional reduction can be achieved in experiments by means of highly anisotropic traps. The Functional Renormalization Group (FRG) allows for a description of both cases in a unified theoretical framework. In three dimensions we discuss with the FRG the influence of high momentum particles onto the density, extend previous approaches to the Unitary Fermi Gas to reach quantitative precision, and study the breakdown of superfluidity due to an asymmetry in the population of the two fermion components. In this context we also investigate the stability of the Sarma phase. For the two-dimensional system scattering theory in reduced dimension plays an important role. We present both the theoretically as well as experimentally relevant aspects thereof. After a qualitative analysis of the phase diagram and the equation of state in two dimensions with the FRG we describe the experimental determination of the phase diagram of the two-dimensional BCS-BEC crossover in collaboration with the group of S. Jochim at PI Heidelberg.

  8. A new crossover operator in genetic programming for object classification.

    Science.gov (United States)

    Zhang, Mengjie; Gao, Xiaoying; Lou, Weijun

    2007-10-01

    The crossover operator has been considered "the centre of the storm" in genetic programming (GP). However, many existing GP approaches to object recognition suggest that the standard GP crossover is not sufficiently powerful in producing good child programs due to the totally random choice of the crossover points. To deal with this problem, this paper introduces an approach with a new crossover operator in GP for object recognition, particularly object classification. In this approach, a local hill-climbing search is used in constructing good building blocks, a weight called looseness is introduced to identify the good building blocks in individual programs, and the looseness values are used as heuristics in choosing appropriate crossover points to preserve good building blocks. This approach is examined and compared with the standard crossover operator and the headless chicken crossover (HCC) method on a sequence of object classification problems. The results suggest that this approach outperforms the HCC, the standard crossover, and the standard crossover operator with hill climbing on all of these problems in terms of the classification accuracy. Although this approach spends a bit longer time than the standard crossover operator, it significantly improves the system efficiency over the HCC method.

  9. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  10. Molecular-scale dynamics of light-induced spin cross-over in a two-dimensional layer

    Science.gov (United States)

    Bairagi, Kaushik; Iasco, Olga; Bellec, Amandine; Kartsev, Alexey; Li, Dongzhe; Lagoute, Jérôme; Chacon, Cyril; Girard, Yann; Rousset, Sylvie; Miserque, Frédéric; Dappe, Yannick J; Smogunov, Alexander; Barreteau, Cyrille; Boillot, Marie-Laure; Mallah, Talal; Repain, Vincent

    2016-01-01

    Spin cross-over molecules show the unique ability to switch between two spin states when submitted to external stimuli such as temperature, light or voltage. If controlled at the molecular scale, such switches would be of great interest for the development of genuine molecular devices in spintronics, sensing and for nanomechanics. Unfortunately, up to now, little is known on the behaviour of spin cross-over molecules organized in two dimensions and their ability to show cooperative transformation. Here we demonstrate that a combination of scanning tunnelling microscopy measurements and ab initio calculations allows discriminating unambiguously between both states by local vibrational spectroscopy. We also show that a single layer of spin cross-over molecules in contact with a metallic surface displays light-induced collective processes between two ordered mixed spin-state phases with two distinct timescale dynamics. These results open a way to molecular scale control of two-dimensional spin cross-over layers. PMID:27425776

  11. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  12. Simultaneous coffee caffeine intake and sleep deprivation alter glucose homeostasis in Iranian men: a randomized crossover trial.

    Science.gov (United States)

    Rasaei, Behrouz; Talib, Ruzita Abd; Noor, Mohd Ismail; Karandish, Majid; Karim, Norimah A

    2016-12-01

    Sleep deprivation and coffee caffeine consumption have been shown to affect glucose homeostasis separately, but the combined effects of these two variables are unknown. Forty-two healthy Iranian men, aged 20-40 years old, were assigned to three groups in a randomised crossover trial involving three treatments with two-week washout periods. Subjects were moderate coffee consumers (coffee (DC treatment, without sugar, 99.9% caffeine-free), and caffeinated coffee (CC treatment, without sugar, 65 mg caffeine/ cup). DC and CC treatments were blinded. At the end of each treatment, fasting serum glucose (using enzyme assays) and insulin (using electrochemiluminescence immunoassay) were measured and, again, two hours after an oral glucose tolerance test (OGTT). Insulin resistance was quantified with the homeostasis model. Repeated measures ANOVA indicated no significant difference between the treatments in fasting serum glucose (p=0.248) or insulin resistance (p=0.079). However, ANOVA demonstrated differences between treatments in fasting serum insulin (p=0.004) and glucose, as well as insulin after OGTT (pcoffee was more adverse for glucose homeostasis compared to decaffeinated coffee in individuals who were simultaneously sleep deprived.

  13. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Virgil [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Della Torre, Edward; Bennett, Lawrence H. [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States); ElBidweihy, Hatem, E-mail: Hatem@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States)

    2014-02-15

    The Gd{sub 5}Ge{sub 2}Si{sub 2} alloy and the off-stoichiometric Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd{sub 5}Ge{sub 2}Si{sub 2} and Ni{sub 50}Mn{sub 35}In{sub 15} alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  14. Crossover transition in bag-like models

    Energy Technology Data Exchange (ETDEWEB)

    Ferroni, Lorenzo; Koch, Volker

    2009-03-13

    We formulate a simple model for a gas of extended hadrons at zero chemical potential by taking inspiration from the compressible bag model. We show that a crossover transition qualitatively similar to lattice QCD can be reproduced by such a system by including some appropriate additional dynamics. Under certain conditions, at high temperature, the system consist of a finite number of infinitely extended bags,which occupy the entire space. In this situation the system behaves as an ideal gas of quarks and gluons.

  15. Generalised sequential crossover of words and languages

    CERN Document Server

    Jeganathan, L; Sengupta, Ritabrata

    2009-01-01

    In this paper, we propose a new operation, Generalised Sequential Crossover (GSCO) of words, which in some sense an abstract model of crossing over of the chromosomes in the living organisms. We extend GSCO over language $L$ iteratively ($GSCO^*(L)$ as well as iterated GSCO over two languages $GSCO^*(L_1,L_2)$). Our study reveals that $GSCO^*(L)$ is subclass of regular languages for any $L$. We compare the different classes of GSCO languages with the prominent sub-regular classes.

  16. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  17. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  18. A quantum genetic algorithm with quantum crossover and mutation operations

    Science.gov (United States)

    SaiToh, Akira; Rahimi, Robabeh; Nakahara, Mikio

    2013-11-01

    In the context of evolutionary quantum computing in the literal meaning, a quantum crossover operation has not been introduced so far. Here, we introduce a novel quantum genetic algorithm that has a quantum crossover procedure performing crossovers among all chromosomes in parallel for each generation. A complexity analysis shows that a quadratic speedup is achieved over its classical counterpart in the dominant factor of the run time to handle each generation.

  19. A Repeating Fast Radio Burst

    CERN Document Server

    Spitler, L G; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-01-01

    Fast Radio Bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measures (i.e. integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of the fast radio bursts has led several authors to hypothesise that they originate in cataclysmic astrophysical events. Here we report the detection of ten additional bursts from the direction of FRB121102, using the 305-m Arecibo telescope. These new bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and wh...

  20. Recursive quantum repeater networks

    CERN Document Server

    Van Meter, Rodney; Horsman, Clare

    2011-01-01

    Internet-scale quantum repeater networks will be heterogeneous in physical technology, repeater functionality, and management. The classical control necessary to use the network will therefore face similar issues as Internet data transmission. Many scalability and management problems that arose during the development of the Internet might have been solved in a more uniform fashion, improving flexibility and reducing redundant engineering effort. Quantum repeater network development is currently at the stage where we risk similar duplication when separate systems are combined. We propose a unifying framework that can be used with all existing repeater designs. We introduce the notion of a Quantum Recursive Network Architecture, developed from the emerging classical concept of 'recursive networks', extending recursive mechanisms from a focus on data forwarding to a more general distributed computing request framework. Recursion abstracts independent transit networks as single relay nodes, unifies software layer...

  1. Expiratory Positive Airway Pressure for Sleep Apnea after Stroke: A Randomized, Crossover Trial.

    Science.gov (United States)

    Wheeler, Natalie C; Wing, Jeffrey J; O'Brien, Louise M; Hughes, Rebecca; Jacobs, Teresa; Claflin, Edward; Chervin, Ronald D; Brown, Devin L

    2016-09-15

    Obstructive sleep apnea (OSA) is common after stroke and predicts poor outcomes. Continuous positive airway pressure (CPAP) treats OSA but is generally poorly tolerated by stroke patients. We assessed whether nasal expiratory positive airway pressure (EPAP), an alternative to CPAP, may be an effective option after acute stroke. We conducted a randomized, controlled, two-period crossover study in which each acute ischemic stroke patient received 1 night of EPAP and 1 night without EPAP while OSA was monitored with a validated device, the Watch-PAT 200. Linear repeated- measures analyses were conducted. Sample size calculations indicated that 18 subjects would be required to detect a 10-point or larger average reduction in the apnea-hypopnea index (AHI, the primary outcome), with use of EPAP, with power ≥ 80% and α = 0.05. Among the 19 subjects who completed the protocol, nasal EPAP treatment was associated with a nonsignificant absolute difference in AHI of -5.73 events/h in the primary analysis (p = 0.183, 95% confidence interval -14.4, 2.97) and a nonsignificant absolute difference in AHI of -5.43 events/h in the subgroup of patients who used nasal EPAP for ≥ 3 h (p = 0.314, 95% confidence interval -16.6, 5.76). This study suggests that EPAP is not an effective alternative to CPAP in acute stroke patients with OSA. Further work is needed to identify other more effective alternatives. ClinicalTrials.gov, ID: NCT01703663. © 2016 American Academy of Sleep Medicine.

  2. Linear combinations come alive in crossover designs.

    Science.gov (United States)

    Shuster, Jonathan J

    2017-10-30

    Before learning anything about statistical inference in beginning service courses in biostatistics, students learn how to calculate the mean and variance of linear combinations of random variables. Practical precalculus examples of the importance of these exercises can be helpful for instructors, the target audience of this paper. We shall present applications to the "1-sample" and "2-sample" methods for randomized short-term 2-treatment crossover studies, where patients experience both treatments in random order with a "washout" between the active treatment periods. First, we show that the 2-sample method is preferred as it eliminates "conditional bias" when sample sizes by order differ and produces a smaller variance. We also demonstrate that it is usually advisable to use the differences in posttests (ignoring baseline and post washout values) rather than the differences between the changes in treatment from the start of the period to the end of the period ("delta of delta"). Although the intent is not to provide a definitive discussion of crossover designs, we provide a section and references to excellent alternative methods, where instructors can provide motivation to students to explore the topic in greater detail in future readings or courses. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Repeatability of Harris Corner Detector

    Institute of Scientific and Technical Information of China (English)

    HU Lili

    2003-01-01

    Interest point detectors are commonly employed to reduce the amount of data to be processed. The ideal interest point detector would robustly select those features which are most appropriate or salient for the application and data at hand. This paper shows that interest points are geometrically stable under different transformations.This property makes interest points very successful in the context of image matching. To measure this property quantatively, we introduce a evaluation criterion: repeatability rate.

  4. Crossover versus Stabilometric Platform for the Treatment of Balance Dysfunction in Parkinson’s Disease: A Randomized Study

    Directory of Open Access Journals (Sweden)

    G. Frazzitta

    2015-01-01

    Full Text Available Balance dysfunctions are a major challenge in the treatment of Parkinson’s disease (PD. Previous studies have shown that rehabilitation can play a role in their treatment. In this study, we have compared the efficacy of two different devices for balance training: stabilometric platform and crossover. We have enrolled 60 PD patients randomly assigned to two groups. The first one (stabilometric group performed a 4-week cycle of balance training, using the stabilometric platform, whereas the second one (crossover group performed a 4-week cycle of balance training, using the crossover. The outcome measures used were Unified Parkinson’s Disease Rating Scale (UPDRS part II, Berg Balance Scale (BBS, Timed Up and Go (TUG, and Six Minutes Walking Test (6MWT. Results showed that TUG, BBS, and UPDRS II improved in both groups. There was not difference in the efficacy of the two balance treatments. Patients in both groups improved also the meters walked in the 6MWT at the end of rehabilitation, but the improvement was better for patients performing crossover training. Our results show that the crossover and the stabilometric platform have the same effect on balance dysfunction of Parkinsonian patients, while crossover gets better results on the walking capacity.

  5. Treadmill training with partial body weight support compared with conventional gait training for low-functioning children and adolescents with nonspastic cerebral palsy: a two-period crossover study.

    Science.gov (United States)

    Su, Ivan Y W; Chung, Kenny K Y; Chow, Daniel H K

    2013-12-01

    Partial body weight-supported treadmill training has been shown to be effective in gait training for patients with neurological disorders such as spinal cord injuries and stroke. Recent applications on children with cerebral palsy were reported, mostly on spastic cerebral palsy with single subject design. There is lack of evidence on the effectiveness of such training for nonspastic cerebral palsy, particularly those who are low functioning with limited intellectual capacity. This study evaluated the effectiveness of partial body weight-supported treadmill training for improving gross motor skills among these clients. A two-period randomized crossover design with repeated measures. A crossover design following an A-B versus a B-A pattern was adopted. The two training periods consisted of 12-week partial body weight-supported treadmill training (Training A) and 12-week conventional gait training (Training B) with a 10-week washout in between. Ten school-age participants with nonspastic cerebral palsy and severe mental retardation were recruited. The Gross Motor Function Measure-66 was administered immediately before and after each training period. Significant improvements in dimensions D and E of the Gross Motor Function Measure-66 and the Gross Motor Ability Estimator were obtained. Our findings revealed that the partial body weight-supported treadmill training was effective in improving gross motor skills for low-functioning children and adolescents with nonspastic cerebral palsy. .

  6. Relationships between anthropometric measures and athletic performance, with special reference to repeated-sprint ability, in the Qatar national soccer team.

    Science.gov (United States)

    Brocherie, Franck; Girard, Olivier; Forchino, Fabricio; Al Haddad, Hani; Dos Santos, Gilvan A; Millet, Grégoire P

    2014-01-01

    The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.

  7. The effect of a short practical warm-up protocol on repeated sprint performance.

    Science.gov (United States)

    Taylor, Jonathan M; Weston, Matthew; Portas, Matthew D

    2013-07-01

    The aim of our study was to investigate the effect of a short, practical, 2-phase warm-up on repeated sprint performance when compared with more traditional warm-up protocols that contain stretching activities. Eleven subelite male soccer players completed a warm-up protocol that commenced with 5 minutes jogging at approximately 65% of maximal heart rate, followed by no stretching, static stretching, or dynamic stretching and finishing with a task-specific high-intensity activity. Using a crossover design, the 3 warm-up protocols were performed in a counterbalanced order with at least 48 hours between sessions. Repeated sprint performance was measured using a repeated sprint test that consisted of 6 × 40-m maximal sprints interspersed with a 20-second recovery. There were trivial differences in mean sprint time (0.2%) and posttest blood lactate (3.1%) between the 2-phase warm-up and the 3-phase warm-up that included dynamic stretching, whereas the short warm-up had a possibly detrimental effect on fastest sprint time (0.7%). Fastest (-1.1%) and mean (-1.2%) sprint times were quicker and posttest blood lactates were higher (13.2%) after the 2-phase warm-up when compared with the 3-phase warm-up that included static stretching. Although it is not harmful to complete a traditional 3-phase warm-up that includes dynamic stretching, it appears practical for athletes preparing for activities dependent on repeated sprint ability to complete a 2-phase warm-up consisting of a cardiovascular and specific high-intensity activity.

  8. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  9. Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?

    Science.gov (United States)

    Mansoor, Kanaan; Shahnawaz, Saba; Rasool, Mariam; Chaudhry, Huwad; Ahuja, Gul; Shahnawaz, Sara

    2016-01-01

    BACKGROUND: Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the automated oscillometric devices stems from the risk mercury poses to the environment. AIM: This study was performed to check the validity of automated oscillometric blood pressure measurements as compared to the manual blood pressure measurements in Karachi, Pakistan. MATERIAL AND METHODS: Blood pressure was recorded in 200 individuals aged 15 and above using both, an automated oscillometric blood pressure device (Dinamap Procare 100) and a manual mercury sphygmomanometer concomitantly. Two nurses were assigned to each patient and the device, arm for taking the reading and nurses were randomly determined. SPSS version 20 was used for analysis. Mean and standard deviation of the systolic and diastolic measurements from each modality were compared to each other and P values of 0.05 or less were considered to be significant. Validation criteria of British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI) were used. RESULTS: Two hundred patients were included. The mean of the difference of systolic was 8.54 ± 9.38 while the mean of the difference of diastolic was 4.21 ± 7.88. Patients were further divided into three groups of different systolic blood pressure 120 to = 150 and > 150, their means were 6.27 ± 8.39 (p-value 0.175), 8.91 ± 8.96 (p-value 0.004) and 10.98 ± 10.49 (p-value 0.001) respectively. In our study 89 patients were previously diagnosed with hypertension; their difference of mean systolic was 9.43 ± 9.89 (p-value 0.000) and difference of mean diastolic was 4.26 ± 7.35 (p-value 0.000). CONCLUSIONS: Systolic

  10. Detection of the effects of repeated dose combined propoxur and heavy metal exposure by measurement of certain toxicological, haematological and immune function parameters in rats.

    Science.gov (United States)

    Institóris, L; Siroki, O; Undeger, U; Basaran, N; Banerjee, B D; Dési, I

    2001-06-21

    In the present study, an immunotoxicity test system, containing general toxicological (body weight gain, organ weights), haematological (WBC,RBC, Ht, mean cell volume of the RBCs, cell content of the femoral bone marrow), and immune function (PFC assay, DTH reaction) investigations, was used for detection the effects of a 4 weeks repeated low dose combined oral exposure of male Wistar rats with propoxur and the heavy metals arsenic or mercury. Two doses of the compounds were used: a higher one (the lowest dose which resulted in significant change of at least one parameter examined in previous dose-effect experiments), and a lower one (the highest dose which proved to be non-effective). The applied doses were: 8.51 and 0.851 mg kg(-1) of propoxur, 13.3 and 3.33 mg kg(-1) of NaAsO(2), and 3.20 and 0.40 mg kg(-1) of HgCl(2). In the combination treatment, the high dose of propoxur was combined with the low dose of arsenic or mercury, and the high doses of each heavy metals were combined with the low dose of propoxur. The main finding of this study was that some of the combinations significantly altered the relative weight of liver, adrenals and kidneys, related to both the untreated and the high dose internal control. Among the immune functions examined, only the PFC content of the spleen showed a trend of changes in certain combinations versus the corresponding high dose control. According to the present results, combined exposure with propoxur and the heavy metals examined can modify the detection limit of the single compounds and/or may alter their toxic effects.

  11. Dissolved Fe(II) in the Pacific Ocean: Measurements from the P16N CLIVAR/CO2 Repeat Hydrography Cruise

    Science.gov (United States)

    Hansard, S. P.; Landing, W. M.; Measures, C. I.

    2006-12-01

    Vertical profiles of seawater Fe(II) concentration were obtained for 37 stations sampled in early 2006, in conjunction with the CLIVAR Repeat Hydrography P16N transect (152° W, Tahiti to Alaska). At each station, seawater samples were collected from 12 target depths (0-1000 m) using trace-metal clean Go-Flo bottles. Upon recovery, Go-Flo bottles were immediately transferred to a Class 100 clean van and sub-sampled for Fe(II) by passing sample water through a 0.2 μm Supor (polyethersulfone) cartridge filter into 125 mL containers, pre-loaded with 25 μL of 6M quartz-distilled HCl (final pH ~~ 6) to slow oxidation. Samples were immediately analyzed for Fe(II) using a luminol-based chemiluminescence method. Total dissolved iron was also determined shipboard by spectrophotometric flow injection analysis. The data collected from this cruise will be presented, along with corroborating data from another North Pacific cruise (PO2). Concentrations of Fe(II) ranged from below detection (meters. Photoreduction of Fe(III) has been cited as a source of Fe(II) in surface waters, and the pattern of attenuation with depth is consistent with this mechanism. Many samples collected at or near the bottom of the profile (500-1000 m) exhibited elevated Fe(II) relative to the mid-depths of the profile. Due to the higher total dissolved iron at depth, the percentage of Fe(II) was low in these samples. Recent studies support the presence of Fe(II) at depth, in association with low or suboxic conditions. In situ processes such as the remineralization of sinking biogenic particles may provide a source for this Fe(II).

  12. Bupivacaine 0.5 % versus articaine 4 % for the removal of lower third molars. A crossover randomized controlled trial

    Science.gov (United States)

    Sancho-Puchades, Manuel; Vílchez-Pérez, Miguel A.; Paredes-García, Jordi; Berini-Aytés, Leonardo; Gay-Escoda, Cosme

    2012-01-01

    Objective: To compare the anesthetic action of 0.5% bupivacaine in relation to 4% articaine, both with 1:200,000 epinephrine, in the surgical removal of lower third molars. As a secondary objective hemodynamic changes using both anesthetics were analyzed. Study Design: Triple-blind crossover randomized clinical trial. Eighteen patients underwent bilateral removal of impacted lower third molars using 0.5% bupivacaine or 4% articaine in two different appointments. Preoperative, intraoperative and postoperative variables were recorded. Differences were assessed with McNemar tests and repeated measures ANOVA tests. Results: Both solutions exhibited similar latency times and intraoperative efficacy. Statistical significant lower pain levels were observed with bupivacaine between the fifth (p=0.011) and the ninth (p=0.007) postoperative hours. Bupivacaine provided significantly longer lasting soft tissue anesthesia (p<0.05). Systolic blood pressure and heart rate values were significantly higher with articaine. Conclusions: Bupivacaine could be a valid alternative to articaine especially due to its early postoperative pain prevention ability. Key words:Bupivacaine, articaine, third molar, anesthesia, postoperative pain. PMID:22143739

  13. Research Update: The mechanocaloric potential of spin crossover compounds

    Science.gov (United States)

    Sandeman, Karl G.

    2016-11-01

    We present a first evaluation of the potential for spin crossover (SCO) compounds to be considered as a new class of giant mechanocaloric effect materials. From literature data on the variation of the spin crossover temperature with pressure, we estimate the maximum available adiabatic temperature change for several compounds and the relatively low pressures that may be required to observe these effects.

  14. Research Update: The mechanocaloric potential of spin crossover compounds

    OpenAIRE

    Sandeman, Karl G.

    2016-01-01

    We present a first evaluation of the potential for spin crossover (SCO) compounds to be considered as a new class of giant mechanocaloric effect materials. From literature data on the variation of the spin crossover temperature with pressure, we estimate the maximum available adiabatic temperature change for several compounds and the relatively low pressures that may be required to observe these effects.

  15. Case-crossover studies of occupational trauma: methodological caveats

    OpenAIRE

    Sorock, G; Lombardi, D; Gabel, C; Smith, G; Mittleman, M

    2001-01-01

    Objectives—The case-crossover study design was developed to examine triggers for the onset of myocardial infarction. This paper seeks to examine selected methodological issues when applying the case-crossover method to the study of traumatic injuries in the work environment.

  16. Jacobi crossover ensembles of random matrices and statistics of transmission eigenvalues

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Santosh; Pandey, Akhilesh, E-mail: skumar.physics@gmail.co, E-mail: ap0700@mail.jnu.ac.i [School of Physical Sciences, Jawaharlal Nehru University, New Delhi - 110067 (India)

    2010-02-26

    We study the transition in conductance properties of chaotic mesoscopic cavities as time-reversal symmetry is broken. We consider the Brownian motion model for transmission eigenvalues for both types of transitions, namely, orthogonal-unitary and symplectic-unitary crossovers depending on the presence or absence of spin-rotation symmetry of the electron. In both cases the crossover is governed by a Brownian motion parameter tau, which measures the extent of time-reversal symmetry breaking. It is shown that the results obtained correspond to the Jacobi crossover ensembles of random matrices. We derive the level density and the correlation functions of higher orders for the transmission eigenvalues. We also obtain the exact expressions for the average conductance, average shot-noise power and variance of conductance, as functions of tau, for the arbitrary number of modes (channels) in the two leads connected to the cavity. Moreover, we give the asymptotic result for the variance of shot-noise power for both the crossovers, the exact results being too long. In the tau -> 0 and tau -> infinity limits, the known results for the orthogonal (or symplectic) and unitary ensembles are reproduced. In the weak time-reversal symmetry breaking regime, our results are shown to be in agreement with the semiclassical predictions.

  17. What about the leader? Crossover of emotional exhaustion and work engagement from followers to leaders.

    Science.gov (United States)

    Wirtz, Nina; Rigotti, Thomas; Otto, Kathleen; Loeb, Carina

    2017-01-01

    Although a growing body of research links leadership behavior to follower health, comparatively little is known about the health effects of being in the lead. This longitudinal study of 315 team members and 67 leaders examined the crossover of emotional exhaustion and work engagement from followers to leaders. Leader emotional self-efficacy was tested as a moderator in the crossover process. Multiple regression analyses revealed that followers' work engagement was positively related to leaders' work engagement eight months later, controlling for followers' tenure with the leader, leader gender, autonomy, workload, and work engagement at Time 1. Leaders' emotional self-efficacy did not moderate the crossover of work engagement. Followers' emotional exhaustion was not directly related to leaders' emotional exhaustion over time. We did find a significant interaction effect for follower emotional exhaustion and leader emotional self-efficacy. This study is the first to show that crossover of emotional exhaustion and work engagement can unfold over time from team members to leaders. Main theoretical implications lie in the finding that-in line with job demands-resources theory-followers' psychological states can pose a demand or resource for leaders, and influence their well-being. For practitioners, our results offer valuable insights regarding the design of organizational health interventions as well as leadership development measures. (PsycINFO Database Record

  18. Hypothesis testing and estimation in ordinal data under a simple crossover design.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2012-01-01

    Since each patient serves as his/her own control, the crossover design can be of use to improve power as compared with the parallel-groups design in studying noncurative treatments to certain chronic diseases. Although the research studies on the crossover design have been quite intensive, the discussions on analyzing ordinal data under such a design are truly limited. We propose using the generalized odds ratio (GOR) for paired sample data to measure the relative effect on patient responses for both treatment and period in ordinal data under a simple crossover trial. Assuming the treatment and period effects are multiplicative, we note that one can easily derive the maximum likelihood estimator (LE) in closed forms for the GOR of treatment and period effects. We develop asymptotic and exact procedures for testing treatment and period effects. We further derive asymptotic and exact interval estimators for the GOR of treatment and period effects. We use the data taken from a crossover trial to assess the clarity of leaflet instructions between two devices among asthma patients to illustrate the use of these test procedures and estimators developed here.

  19. Crossover Equation of State Models Applied to the Critical Behavior of Xenon

    Science.gov (United States)

    Garrabos, Y.; Lecoutre, C.; Marre, S.; Guillaument, R.; Beysens, D.; Hahn, I.

    2015-03-01

    The turbidity () measurements of Güttinger and Cannell (Phys Rev A 24:3188-3201, 1981) in the temperature range along the critical isochore of homogeneous xenon are reanalyzed. The singular behaviors of the isothermal compressibility () and the correlation length () predicted from the master crossover functions are introduced in the turbidity functional form derived by Puglielli and Ford (Phys Rev Lett 25:143-146, 1970). We show that the turbidity data are thus well represented by the Ornstein-Zernike approximant, within 1 % precision. We also introduce a new crossover master model (CMM) of the parametric equation of state for a simple fluid system with no adjustable parameter. The CMM model and the phenomenological crossover parametric model are compared with the turbidity data and the coexisting liquid-gas density difference (). The excellent agreement observed for , , , and in a finite temperature range well beyond the Ising-like preasymptotic domain confirms that the Ising-like critical crossover behavior of xenon can be described in conformity with the universal features estimated by the renormalization-group methods. Only 4 critical coordinates of the vapor-liquid critical point are needed in the (pressure, temperature, molecular volume) phase surface of xenon.

  20. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    OpenAIRE

    Smedslund Geir; Zangi Heidi Andersen; Mowinckel Petter; Hagen Kåre Birger

    2013-01-01

    Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71)...

  1. Deformation Crossover: from nano to meso scale

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Sheng [ORNL; Stoica, Alexandru Dan [ORNL; Wang, Xun-Li [ORNL; Liu, Chain T [ORNL; Horton Jr, Joe A [ORNL; Brown, Donald [Los Alamos National Laboratory (LANL); Clausen, B [Los Alamos National Laboratory (LANL); Liaw, Peter K [University of Tennessee, Knoxville (UTK)

    2009-01-01

    By investigating intergranular strains using in-situ high-energy x-ray and neutron diffraction, we demonstrate significantly different deformation behavior from previously observed in nanocrystalline and ultrafine-grained Ni. Little intergranular strain or texture change was found in nanocrystalline Ni indicating a grain boundary mediated deformation mechanism. A remarkable intergranular strain build-up was observed in ultrafine-grained Ni, which was attributed to dislocation activities, but the unusual angular dependence of intergranular strains gave evidence of stress relaxation by deformation twinning, as confirmed by TEM observations. From the intergranular strain evolution and the texture change, clear evidence of deformation crossovers is presented in Ni with grain sizes from nano to meso scale.

  2. Neutrino dynamics below the electroweak crossover

    Energy Technology Data Exchange (ETDEWEB)

    Ghiglieri, J.; Laine, M. [AEC, Institute for Theoretical Physics, University of Bern,Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2016-07-12

    We estimate the thermal masses and damping rates of active (m< eV) and sterile (M∼ GeV) neutrinos with thermal momenta k∼3T at temperatures below the electroweak crossover (5 GeV 130 GeV remains an option. Our differential rates are tabulated in a form suitable for studies of specific scenarios with given neutrino Yukawa matrices.

  3. Fuel cell membranes and crossover prevention

    Science.gov (United States)

    Masel, Richard I.; York, Cynthia A.; Waszczuk, Piotr; Wieckowski, Andrzej

    2009-08-04

    A membrane electrode assembly for use with a direct organic fuel cell containing a formic acid fuel includes a solid polymer electrolyte having first and second surfaces, an anode on the first surface and a cathode on the second surface and electrically linked to the anode. The solid polymer electrolyte has a thickness t:.gtoreq..times..times..times..times. ##EQU00001## where C.sub.f is the formic acid fuel concentration over the anode, D.sub.f is the effective diffusivity of the fuel in the solid polymer electrolyte, K.sub.f is the equilibrium constant for partition coefficient for the fuel into the solid polymer electrolyte membrane, I is Faraday's constant n.sub.f is the number of electrons released when 1 molecule of the fuel is oxidized, and j.sub.f.sup.c is an empirically determined crossover rate of fuel above which the fuel cell does not operate.

  4. Extended precedence preservative crossover for job shop scheduling problems

    Science.gov (United States)

    Ong, Chung Sin; Moin, Noor Hasnah; Omar, Mohd

    2013-04-01

    Job shop scheduling problems (JSSP) is one of difficult combinatorial scheduling problems. A wide range of genetic algorithms based on the two parents crossover have been applied to solve the problem but multi parents (more than two parents) crossover in solving the JSSP is still lacking. This paper proposes the extended precedence preservative crossover (EPPX) which uses multi parents for recombination in the genetic algorithms. EPPX is a variation of the precedence preservative crossover (PPX) which is one of the crossovers that perform well to find the solutions for the JSSP. EPPX is based on a vector to determine the gene selected in recombination for the next generation. Legalization of children (offspring) can be eliminated due to the JSSP representation encoded by using permutation with repetition that guarantees the feasibility of chromosomes. The simulations are performed on a set of benchmarks from the literatures and the results are compared to ensure the sustainability of multi parents recombination in solving the JSSP.

  5. The Pentapeptide Repeat Proteins

    Energy Technology Data Exchange (ETDEWEB)

    Vetting,M.; Hegde, S.; Fajardo, J.; Fiser, A.; Roderick, S.; Takiff, H.; Blanchard, J.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S, T,A, V][D, N][L, F]-[S, T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Mycobacterium tuberculosis. The structure revealed that the pentapeptide repeats encode the folding of a novel right-handed quadrilateral {beta}-helix. MfpA binds to DNA gyrase and inhibits its activity. The rod-shaped, dimeric protein exhibits remarkable size, shape and electrostatic similarity to DNA.

  6. Effect of ischemic preconditioning on repeated sprint ability in team sport athletes.

    Science.gov (United States)

    Gibson, Neil; Mahony, Ben; Tracey, Claire; Fawkner, Samantha; Murray, Andrew

    2015-01-01

    This study investigated whether ischemic preconditioning (IPC) in a trained population affected repeated sprint performance. A secondary aim was to assess responses according to gender. Sixteen (nine females and seven males) well trained team sport athletes took part in a randomised crossover study design. Participants underwent an IPC and placebo treatment involving three periods of 5 min occlusion applied unilaterally (3 × 5 min occlusion to each leg) at either 220 mmHg or 50 mmHg. Each period of occlusion was followed by 5 min reperfusion. Following treatment 5 × 6 s maximal effort sprints were undertaken on a cycle ergometer against 7.5% body mass, each interspersed by 24 s recovery. Measured parameters included peak power, total power, percentage decrement, post-exercise blood lactate and ratings of perceived exertion. Nor within subject main effect for IPC was observed, neither was there an interaction effect with gender. Effect sizes were trivial (ES repeated sprint performance. A lower blood lactate response in female participants following IPC may suggest improved blood flow through vasodilation.

  7. Pain sensitivity is normalized after a repeated bout of eccentric exercise.

    Science.gov (United States)

    Hosseinzadeh, Mahdi; Andersen, Ole K; Arendt-Nielsen, Lars; Madeleine, Pascal

    2013-10-01

    The purpose of this study was to investigate the effect of repeated bouts of eccentric exercise on the nociceptive withdrawal reflex (NWR) threshold, a measure of sensitivity in the spinal nociceptive system. Sixteen healthy students (age 25.7 ± 0.6 years, BMI 24.8 ± 1 kg m(-2)) participated in this randomized, controlled, crossover study. Two identical bouts of high-intensity eccentric exercises were performed on the tibialis anterior muscle 7 days apart. Control sessions involving no exercise were performed 4 weeks apart the exercise sessions. Pressure pain thresholds (PPT) and the NWR threshold were recorded before, immediately after, and 1 day after both bouts of exercise. Pressure pain thresholds decreased significantly at two of the muscle belly sites on the day after initial bout compared with baseline. NWR threshold decreased by 25 ± 4 % immediately after initial bout and by 30 ± 5 % the next day (p eccentric exercise indicating that both localized and generalized pain sensitivity were normalized. In conclusion, this study for the first time documented that an initial bout of unaccustomed high-intensity eccentric exercise, which results in muscle soreness can induce central sensitization. A repeated bout of exercise, however, facilitates inherent protective spinal mechanisms against the development of muscle soreness.

  8. HAPCAD: An open-source tool to detect PCR crossovers in next-generation sequencing generated HLA data.

    Science.gov (United States)

    McDevitt, Shana L; Bredeson, Jessen V; Roy, Scott W; Lane, Julie A; Noble, Janelle A

    2016-03-01

    Next-generation sequencing (NGS) based HLA genotyping can generate PCR artifacts corresponding to IMGT/HLA Database alleles, for which multiple examples have been observed, including sequence corresponding to the HLA-DRB1(∗)03:42 allele. Repeat genotyping of 131 samples, previously genotyped as DRB1(∗)03:01 homozygotes using probe-based methods, resulted in the heterozygous call DRB1(∗)03:01+DRB1(∗)03:42. The apparent rare DRB1(∗)03:42 allele is hypothesized to be a "hybrid amplicon" generated by PCR crossover, a process in which a partial PCR product denatures from its template, anneals to a different allele template, and extends to completion. Unlike most PCR crossover products, "hybrid amplicons" always corresponds to an IMGT/HLA Database allele, necessitating a case-by-case analysis of whether its occurrence reflects the actual allele or is simply the result of PCR crossover. The Hybrid Amplicon/PCR Crossover Artifact Detector (HAPCAD) program mimics jumping PCR in silico and flags allele sequences that may also be generated as hybrid amplicon.

  9. Repeating the Past

    Science.gov (United States)

    Moore, John W.

    1998-05-01

    As part of the celebration of the Journal 's 75th year, we are scanning each Journal issue from 25, 50, and 74 years ago. Many of the ideas and practices described are so similar to present-day "innovations" that George Santayana's adage (1) "Those who cannot remember the past are condemned to repeat it" comes to mind. But perhaps "condemned" is too strong - sometimes it may be valuable to repeat something that was done long ago. One example comes from the earliest days of the Division of Chemical Education and of the Journal.

  10. Repeatability and Minimal Detectable Change in Longitudinal Median Nerve Excursion Measures During Upper Limb Neurodynamic Techniques in a Mixed Population: A Pilot Study Using Musculoskeletal Ultrasound Imaging.

    Science.gov (United States)

    Paquette, Philippe; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2015-07-01

    This study determined test-retest reliability and minimum detectable change in longitudinal median nerve excursion during upper limb neurodynamic tests (ULNTs). Seven participants with unilateral or bilateral carpal tunnel syndrome and 11 healthy participants were randomly tested with two ULNTs (i.e., tensioner and slider). Each ULNT was performed three times each at 45° and 90° of shoulder abduction on two separate visits. Video sequences of median nerve excursion, recorded by a physical therapist using ultrasound imaging, were quantified using computer software. The generalizability theory, encompassing a G-Study and a D-study, measured the dependability coefficient (Φ) along with standard error of measurement (SEM) accuracy and allowed various testing protocols to be proposed. The highest reliability (Φ = 0.84) and lowest minimal measurement error (SEM = 0.58 mm) of the longitudinal median nerve excursion were reached during the ULNT-slider performed with 45° of shoulder abduction and when measures obtained from three different image sequences recorded during a single visit were averaged. It is recommended that longitudinal median nerve excursion measures computed from three separate image sequences recorded during a single visit be averaged in clinical practice. Ideally, adding a second visit (six image sequences) is also suggested in research protocols.

  11. Systematically Controlling for the Influence of Age, Sex, Hertz and Time Post-Whole-Body Vibration Exposure on Four Measures of Physical Performance in Community-Dwelling Older Adults: A Randomized Cross-Over Study

    Directory of Open Access Journals (Sweden)

    Harold L. Merriman

    2011-01-01

    Full Text Available Though popular, there is little agreement on what whole-body vibration (WBV parameters will optimize performance. This study aimed to clarify the effects of age, sex, hertz and time on four physical function indicators in community-dwelling older adults (=32. Participants were exposed to 2 min WBV per session at either 2 Hz or 26 Hz and outcome measures were recorded at 2, 20 and 40 min post-WBV. Timed get up-and-go and chair sit-and-reach performances improved post-WBV for both sexes, were significantly different between 2 Hz and 26 Hz treatments (≤0.05 and showed statistically significant interactions between age and gender (≤0.01. Counter movement jump and timed one-legged stance performances showed a similar but non-significant response to 2 Hz and 26 Hz treatments, though male subjects showed a distinct trended response. Age and gender should be statistically controlled and both 2 Hz and 26 Hz exert a treatment effect.

  12. Contrasted patterns of crossover and non-crossover at Arabidopsis thaliana meiotic recombination hotspots.

    Directory of Open Access Journals (Sweden)

    Jan Drouaud

    2013-11-01

    Full Text Available The vast majority of meiotic recombination events (crossovers (COs and non-crossovers (NCOs cluster in narrow hotspots surrounded by large regions devoid of recombinational activity. Here, using a new molecular approach in plants, called "pollen-typing", we detected and characterized hundreds of CO and NCO molecules in two different hotspot regions in Arabidopsis thaliana. This analysis revealed that COs are concentrated in regions of a few kilobases where their rates reach up to 50 times the genome average. The hotspots themselves tend to cluster in regions less than 8 kilobases in size with overlapping CO distribution. Non-crossover (NCO events also occurred in the two hotspots but at very different levels (local CO/NCO ratios of 1/1 and 30/1 and their track lengths were quite small (a few hundred base pairs. We also showed that the ZMM protein MSH4 plays a role in CO formation and somewhat unexpectedly we also found that it is involved in the generation of NCOs but with a different level of effect. Finally, factors acting in cis and in trans appear to shape the rate and distribution of COs at meiotic recombination hotspots.

  13. Contrasted patterns of crossover and non-crossover at Arabidopsis thaliana meiotic recombination hotspots.

    Directory of Open Access Journals (Sweden)

    Jan Drouaud

    2013-11-01

    Full Text Available The vast majority of meiotic recombination events (crossovers (COs and non-crossovers (NCOs cluster in narrow hotspots surrounded by large regions devoid of recombinational activity. Here, using a new molecular approach in plants, called "pollen-typing", we detected and characterized hundreds of CO and NCO molecules in two different hotspot regions in Arabidopsis thaliana. This analysis revealed that COs are concentrated in regions of a few kilobases where their rates reach up to 50 times the genome average. The hotspots themselves tend to cluster in regions less than 8 kilobases in size with overlapping CO distribution. Non-crossover (NCO events also occurred in the two hotspots but at very different levels (local CO/NCO ratios of 1/1 and 30/1 and their track lengths were quite small (a few hundred base pairs. We also showed that the ZMM protein MSH4 plays a role in CO formation and somewhat unexpectedly we also found that it is involved in the generation of NCOs but with a different level of effect. Finally, factors acting in cis and in trans appear to shape the rate and distribution of COs at meiotic recombination hotspots.

  14. Impact of volunteer-related and methodology-related factors on the reproducibility of brachial artery flow-mediated vasodilation: analysis of 672 individual repeated measurements.

    NARCIS (Netherlands)

    Mil, A.C.C.M. van; Greyling, A.; Zock, P.L.; Geleijnse, J.M.; Hopman, M.T.E.; Mensink, R.P.; Reesink, K.D.; Green, D.J.; Ghiadoni, L.; Thijssen, D.H.J.

    2016-01-01

    OBJECTIVES: Brachial artery flow-mediated dilation (FMD) is a popular technique to examine endothelial function in humans. Identifying volunteer and methodological factors related to variation in FMD is important to improve measurement accuracy and applicability. METHODS: Volunteer-related and

  15. 数字光纤直放站中的时延测量与校正%The Measurement and Adjustment of Time Delay in Digital Optical Fiber Repeater

    Institute of Scientific and Technical Information of China (English)

    金绍春

    2011-01-01

    提出了应用于数字光纤直放站的时延测量与校正方法。阐述了数字光纤直放站的结构、时延测量的目的与原理、时延校正的计算。时延测量以CPRI协议为基础,包括光纤时延测量、转发时延测量。时延校正分下行时延校正和上行时延校正。下行时延校正是使同一台REC送出的IQ信号在不同的RE中能够同时射频发送出去。上行时延校正是使不同的RE接收到的IQ信号能够正确进行功率合成。%The Method of measurement and adjustment of time delay which applies to digital optical fiber repeater has been presented. The structure of digital optical fiber repeater, the purpose and principle of time delay measurement, the calculation of time delay adjustment, has been represented. The measurement of time delay that based on CPRI protocol includes the measurement of optical fiber time delay and the measurement of forward time delay. The time delay adjustment includes uplink time delay adjustment and downlink time delay adjustment. The purpose of downlink time delay adjustment is to ensure IQ signals in different REs which comes from the same REC transmit synchronously by radio frequency signals. The purpose of uplink time delay adjustment is to ensure received IQ signals by different REs synthesize correctly by power.

  16. All-optical repeater.

    Science.gov (United States)

    Silberberg, Y

    1986-06-01

    An all-optical device containing saturable gain, saturable loss, and unsaturable loss is shown to transform weak, distorted optical pulses into uniform standard-shape pulses. The proposed device performs thresholding, amplification, and pulse shaping as required from an optical repeater. It is shown that such a device could be realized by existing semiconductor technology.

  17. Bidirectional Manchester repeater

    Science.gov (United States)

    Ferguson, J.

    1980-01-01

    Bidirectional Manchester repeater is inserted at periodic intervals along single bidirectional twisted pair transmission line to detect, amplify, and transmit bidirectional Manchester 11 code signals. Requiring only 18 TTL 7400 series IC's, some line receivers and drivers, and handful of passive components, circuit is simple and relatively inexpensive to build.

  18. The impact of dark chocolate intake on arterial elasticity in individuals with HIV/AIDS undergoing ART: a randomized, double-blind, crossover trial.

    Science.gov (United States)

    Teixeira, Andrea Mariana Nunes da Costa; Luzia, Liania Alves; de Souza, Suelen Jorge; de Almeida Petrilli, Aline; Pontilho, Patrícia de Moraes; de Souza, Jose Maria Pacheco; Segurado, Aluísio Augusto Cotrim; Efraim, Priscila; Picone, Camila de Melo; Rondo, Patrícia Helen de Carvalho

    2017-06-21

    An increase in the frequency of cardiovascular diseases has been observed in the HIV/AIDS population. Studies involving healthy subjects or subjects with other diseases have shown benefits of chocolate supplementation on endothelial function and vasodilation. We evaluate the impact of chocolate consumption on arterial elasticity in people living with human immunodeficiency virus - PLHIV. A double-blind, crossover trial including 110 PLHIV (19 to 59 years) on antiretroviral therapy - ART for at least 6 months and with a viral load of chocolate or placebo with a 15-d washout period. Each participant received one of the two sequences: A (dark chocolate, placebo chocolate); B (placebo chocolate, dark chocolate). Arterial elasticity was measured using the HDI/PulseWave™ CR-2000 CardioVascular Profiling System®. Body composition, lipid profile, C-reactive protein, and thiobarbituric acid reactive substances were also assessed. Analysis of variance (ANOVA) for repeated measures using the Stata 11.0® program was used for cross-over analysis. Most subjects were men (59.0%) and Caucasian (46.1%) and the mean age was 44.6 ± 7.1 years. The mean time since diagnosis of HIV infection was 13.7 ± 5.3 years and the mean duration of ART was 12.9 ± 4.2 years. Chocolate consumption resulted in significant alterations in the large artery elasticity index - LAEI (p = 0.049) and the mean concentration of HDL-c was higher after supplementation with dark chocolate (p = 0.045). This is the first study to evaluate the effect of chocolate on arterial elasticity in PLHIV. The results showed that dark chocolate consumption for 15 days improved the elastic properties of the LAEI in PLHIV. These findings, added to the noninvasive method used, may expand the knowledge of CVDs in this population.

  19. Whole scalp resting state EEG of oscillatory brain activity shows no parametric relationship with psychoacoustic and psychosocial assessment of tinnitus: A repeated measures study.

    Science.gov (United States)

    Pierzycki, Robert H; McNamara, Adam J; Hoare, Derek J; Hall, Deborah A

    2016-01-01

    Tinnitus is a perception of sound that can occur in the absence of an external stimulus. A brief review of electroencephalography (EEG) and magnetoencephalography (MEG) literature demonstrates that there is no clear relationship between tinnitus presence and frequency band power in whole scalp or source oscillatory activity. Yet a preconception persists that such a relationship exists and that resting state EEG could be utilised as an outcome measure for clinical trials of tinnitus interventions, e.g. as a neurophysiological marker of therapeutic benefit. To address this issue, we first examined the test-retest correlation of EEG band power measures in tinnitus patients (n = 42). Second we examined the evidence for a parametric relationship between numerous commonly used tinnitus variables (psychoacoustic and psychosocial) and whole scalp EEG power spectra, directly and after applying factor reduction techniques. Test-retest correlation for both EEG band power measures and tinnitus variables were high. Yet we found no relationship between whole scalp EEG band powers and psychoacoustic or psychosocial variables. We conclude from these data that resting state whole scalp EEG should not be used as a biomarker for tinnitus and that greater caution should be exercised in regard to reporting of findings to avoid confirmation bias. The data was collected during a randomised controlled trial registered at ClinicalTrials.gov (Identifier: NCT01541969).

  20. Crossovers get a boost in Brassica allotriploid and allotetraploid hybrids.

    Science.gov (United States)

    Leflon, Martine; Grandont, Laurie; Eber, Frédérique; Huteau, Virginie; Coriton, Olivier; Chelysheva, Liudmila; Jenczewski, Eric; Chèvre, Anne-Marie

    2010-07-01

    Meiotic crossovers are necessary to generate balanced gametes and to increase genetic diversity. Even if crossover number is usually constrained, recent results suggest that manipulating karyotype composition could be a new way to increase crossover frequency in plants. In this study, we explored this hypothesis by analyzing the extent of crossover variation in a set of related diploid AA, allotriploid AAC, and allotetraploid AACC Brassica hybrids. We first used cytogenetic methods to describe the meiotic behavior of the different hybrids. We then combined a cytogenetic estimation of class I crossovers in the entire genome by immunolocalization of a key protein, MutL Homolog1, which forms distinct foci on meiotic chromosomes, with genetic analyses to specifically compare crossover rates between one pair of chromosomes in the different hybrids. Our results showed that the number of crossovers in the allotriploid AAC hybrid was higher than in the diploid AA hybrid. Accordingly, the allotetraploid AACC hybrid showed an intermediate behavior. We demonstrated that this increase was related to hybrid karyotype composition (diploid versus allotriploid versus allotetraploid) and that interference was maintained in the AAC hybrids. These results could provide another efficient way to manipulate recombination in traditional breeding and genetic studies.

  1. Repetibilidade e número mínimo de medições para caracteres de cacho de bacabi (Oenocarpus mapora Repeatability and minimum number of measurements for characters of bacabi palm (Oenocarpus mapora racemes

    Directory of Open Access Journals (Sweden)

    Maria do Socorro Padilha de Oliveira

    2010-12-01

    potential for commercial and food uses, but has not been well studied. The objectives of this study were to estimate the repeatability coefficients, determine predictability and the number of measurements needed for raceme characters of this palm. 27 individuals of bacabi that belong to the Germplasm Bank of Oenocarpus/Jessenia at Embrapa Eastern Amazon, in Belém, PA, Brazil were evaluated. Three fully matured racemes from each plant were sampled to measure six characters: total weight of raceme (TWR and fruit weight per raceme (FWR, number of rachillae per raceme (NRR, rachis length per raceme (RLR, weight of 100 fruits (WHF and fruit yield per raceme (FER. The repeatability estimates were obtained by three statistical methods: analysis of variance; principal components; and structural analysis. For all characters, the estimates of repeatability coefficients presented values with very similar magnitudes in the three methods. The estimates of repeatability coefficients and determination coefficients were relatively high (r 0.60 and R2 81.7% for the characters FER and NRR, showing genotype regularity for these raceme measurements. For these characters, the minimum number of racemes necessary to estimate the true character value of the genotypes was thirteen (FER and five (NRR, with 95% reliability. The remaining characters showed repeatabilities and determination coefficients with medium to low values, indicating the need for better environmental control to make the measurements.

  2. The child accident repeater: a review.

    Science.gov (United States)

    Jones, J G

    1980-04-01

    The child accident repeater is defined as one who has at least three accidents that come to medical attention within a year. The accident situation has features in common with those of the child who has a single accident through simple "bad luck", but other factors predispose him to repeated injury. In the child who has a susceptible personality, a tendency for accident repetition may be due to a breakdown in adjustment to a stressful environment. Prevention of repeat accidents should involve the usual measures considered appropriate for all children as well as an attempt to provide treatment of significant maladjustment and modification of a stressful environment.

  3. Pharmacology of ayahuasca administered in two repeated doses.

    Science.gov (United States)

    Dos Santos, Rafael G; Grasa, Eva; Valle, Marta; Ballester, Maria Rosa; Bouso, José Carlos; Nomdedéu, Josep F; Homs, Rosa; Barbanoj, Manel J; Riba, Jordi

    2012-02-01

    Ayahuasca is an Amazonian tea containing the natural psychedelic 5-HT(2A/2C/1A) agonist N,N-dimethyltryptamine (DMT). It is used in ceremonial contexts for its visionary properties. The human pharmacology of ayahuasca has been well characterized following its administration in single doses. To evaluate the human pharmacology of ayahuasca in repeated doses and assess the potential occurrence of acute tolerance or sensitization. In a double-blind, crossover, placebo-controlled clinical trial, nine experienced psychedelic drug users received PO the two following treatment combinations at least 1 week apart: (a) a lactose placebo and then, 4 h later, an ayahuasca dose; and (b) two ayahuasca doses 4 h apart. All ayahuasca doses were freeze-dried Amazonian-sourced tea encapsulated to a standardized 0.75 mg DMT/kg bodyweight. Subjective, neurophysiological, cardiovascular, autonomic, neuroendocrine, and cell immunity measures were obtained before and at regular time intervals until 12 h after first dose administration. DMT plasma concentrations, scores in subjective and neurophysiological variables, and serum prolactin and cortisol were significantly higher after two consecutive doses. When effects were standardized by plasma DMT concentrations, no differences were observed for subjective, neurophysiological, autonomic, or immunological effects. However, we observed a trend to reduced systolic blood pressure and heart rate, and a significant decrease for growth hormone (GH) after the second ayahuasca dose. Whereas there was no clear-cut tolerance or sensitization in the psychological sphere or most physiological variables, a trend to lower cardiovascular activation was observed, together with significant tolerance to GH secretion.

  4. The fragile-to-strong dynamic crossover transition in confined water: nuclear magnetic resonance results

    Science.gov (United States)

    Mallamace, F.; Broccio, M.; Corsaro, C.; Faraone, A.; Wanderlingh, U.; Liu, L.; Mou, C.-Y.; Chen, S. H.

    2006-04-01

    By means of a nuclear magnetic resonance experiment, we give evidence of the existence of a fragile-to-strong dynamic crossover transition (FST) in confined water at a temperature TL=223±2K. We have studied the dynamics of water contained in 1D cylindrical nanoporous matrices (MCM-41-S) in the temperature range 190-280K, where experiments on bulk water were so far hampered by crystallization. The FST is clearly inferred from the T dependence of the inverse of the self-diffusion coefficient of water (1/D) as a crossover point from a non-Arrhenius to an Arrhenius behavior. The combination of the measured self-diffusion coefficient D and the average translational relaxation time ⟨τT⟩, as measured by neutron scattering, shows the predicted breakdown of Stokes-Einstein relation in deeply supercooled water.

  5. The fragile-to-strong dynamic crossover transition in confined water: nuclear magnetic resonance results.

    Science.gov (United States)

    Mallamace, F; Broccio, M; Corsaro, C; Faraone, A; Wanderlingh, U; Liu, L; Mou, C-Y; Chen, S H

    2006-04-28

    By means of a nuclear magnetic resonance experiment, we give evidence of the existence of a fragile-to-strong dynamic crossover transition (FST) in confined water at a temperature T(L)=223+/-2 K. We have studied the dynamics of water contained in 1D cylindrical nanoporous matrices (MCM-41-S) in the temperature range 190-280 K, where experiments on bulk water were so far hampered by crystallization. The FST is clearly inferred from the T dependence of the inverse of the self-diffusion coefficient of water (1D) as a crossover point from a non-Arrhenius to an Arrhenius behavior. The combination of the measured self-diffusion coefficient D and the average translational relaxation time tau(T), as measured by neutron scattering, shows the predicted breakdown of Stokes-Einstein relation in deeply supercooled water.

  6. Analysis of multi-step transitions in spin crossover nanochains

    Energy Technology Data Exchange (ETDEWEB)

    Chiruta, Daniel [GEMaC, Université de Versailles Saint-Quentin-en-Yvelines, CNRS-UVSQ (UMR 8635), 78035 Versailles Cedex (France); LISV, Université de Versailles Saint-Quentin-en-Yvelines, 78140 Velizy (France); Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University, Suceava 720229 (Romania); Linares, Jorge, E-mail: jorge.linares@uvsq.fr [GEMaC, Université de Versailles Saint-Quentin-en-Yvelines, CNRS-UVSQ (UMR 8635), 78035 Versailles Cedex (France); Garcia, Yann, E-mail: yann.garcia@uclouvain.be [Institute of Condensed Matter and Nanosciences, Université Catholique de Louvain, Molecules, Solids and Reactivity (IMCN/MOST), Place Louis Pasteur, 1, 1348 Louvain-la-Neuve (Belgium); Dimian, Mihai [Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University, Suceava 720229 (Romania); Dahoo, Pierre Richard [LATMOS, Université de Versailles-Saint-Quentin-en-Yvelines, CNRS-UPMC-UVSQ (UMR 8190), 78280 Guyancourt (France)

    2014-02-01

    The temperature driven phase transition occurring in spin crossover nanochains has been studied by an Ising-like model considering both short-range and long-range interactions. Various types of spin crossover profiles have been described in this framework, including a novel three-step transition identified in a nanosystem with eight molecules, which is modeled for the first time. A special interest has been also given to stepwise transitions accompanied by two hysteresis loops. The edge and size effects on spin crossover behavior have been investigated in order to get a deeper insight of the underlying mechanisms involved in these unusual spin transitions.

  7. Burnout as a risk factor for antidepressant treatment - a repeated measures time-to-event analysis of 2936 Danish human service workers

    DEFF Research Database (Denmark)

    Madsen, Ida E H; Lange, Theis; Borritz, Marianne

    2015-01-01

    Burnout is a state of emotional exhaustion, feelings of reduced personal accomplishment, and withdrawal from work thought to occur as a consequence of prolonged occupational stress. The condition is not included in the diagnostic classifications, but is considered likely to develop into depressive...... disorder in some cases. We examined the prospective association between burnout and antidepressant treatment, as an indicator of clinically significant mental disorder. We further investigated potential effect-modifiers of the association, to identify factors that may prevent this progression of burnout...... modeling, examining the risk of entering antidepressant treatment in relation to the level of work-related burnout measured by the Copenhagen Burnout inventory. As effect-modifiers we examined both sociodemographic factors and a range of psychosocial work environment factors. The level of burnout predicted...

  8. County level socioeconomic position, work organization and depression disorder: a repeated measures cross-classified multilevel analysis of low-income nursing home workers.

    Science.gov (United States)

    Muntaner, Carles; Li, Yong; Xue, Xiaonan; Thompson, Theresa; O'Campo, Patricia; Chung, Haejoo; Eaton, William W

    2006-12-01

    This study simultaneously tests the effect of county, organizational, workplace, and individual level variables on depressive disorders among low-income nursing assistants employed in US nursing homes. A total of 482 observations are used from two waves of survey data collection, with an average two-year interval between initial and follow-up surveys. The overall response rate was 62 percent. The hierarchically structured data was analyzed using multilevel modeling to account for cross-classifications across levels of data. Nursing assistants working in nursing homes covered by a single union in three states were asked about aspects of their working conditions, job stress, physical and mental health status, individual and family health-care needs, household economics and household strain. The 241 nursing assistants who participated in this study were employed in 34 nursing homes and lived in 49 counties of West Virginia, Ohio and Kentucky. The study finds that emotional strain, related to providing direct care to elderly and disabled clients, is associated with depressive disorder, as is nursing home ownership type (for-profit versus not-for-profit). However, when controlling for county level socioeconomic variables (Gini index and proportion of African Americans living in the county), neither workplace nor organizational level variables were found to be statistically significant associated with depressive disorder. This study supports previous findings that emotional demand in health-care environments is an important correlate of mental health. It also adds empirical evidence to support a link between financial strain and depression in US women. While this study does not find that lack of a seniority wage benefits--a factor that can conceivably exacerbate financial strain over time--is associated with depressive disorder among low-income health-care workers, it does find county level measures of poverty to be statistically significant predictors of depressive

  9. Dynamics of Graft Function Measured by DNA-Technology in a Patient with Severe Aplastic Anemia and Repeated Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Anna Karastaneva

    2014-01-01

    Full Text Available Although bone marrow transplantation (BMT from an HLA identical sibling is considered as treatment of choice in pediatric patients with severe aplastic anemia (SAA, a significant number of them experience graft failure (GF after BMT. We report a case of an 8-year-old male patient with SAA who presented with a complicated posttransplant course due to parvovirus B19 infection and GF. A subsequent attempt to support the graft by antithymocyte globulin (ATG and a peripheral stem cell boost resulted in transitory autologous recovery of hematopoiesis followed by mixed chimerism, supported by donor lymphocyte infusions (DLIs and finally graft rejection with relapse of SAA. Permanent complete chimerism was achieved by a second BMT. Dynamics of graft function, measured by a single nucleotide polymorphism (SNPs analysis, are discussed.

  10. Long-term aerobic exercise and omega-3 supplementation modulate osteoporosis through inflammatory mechanisms in post-menopausal women: a randomized, repeated measures study

    Directory of Open Access Journals (Sweden)

    Kanaley Jill

    2011-10-01

    Full Text Available Abstract Background Evidence indicates that dietary fats and physical activity influence bone health. The purpose of this study was to examine the effects of long-term aerobic exercise and omega-3 (N-3 supplementation on serum inflammatory markers, bone mineral density (BMD, and bone biomarkers in post-menopausal women. Methods Seventy-nine healthy sedentary post-menopausal women aged 58-78 years participated in this study. Subjects were randomized to one of 4 groups: exercise + supplement (E+S, n = 21, exercise (E, n = 20, supplement (S, n = 20, and control (Con, n = 18 groups. The subjects in the E+S and E groups performed aerobic exercise training (walking and jogging up to 65% of HRmax, three times a week for 24 weeks. Subjects in the E+S and S groups consumed 1000 mg/d N-3 for 24 weeks. The lumbar spine (L2-L4 and femoral neck BMD, serum tumor necrosis factor (TNF α, interleukin (IL 6, prostaglandin (PG E2, estrogen, osteocalcin, 1, 25-dihydroxyvitamin D3 (1, 25 Vit D, C-telopeptide (CTX, parathyroid hormone (PTH and calcitonin (CT were measured at baseline, the end of week 12 and 24. Results Serum estrogen, osteocalcin, 1, 25 Vit D, CT, L2-L4 and femoral neck BMD measures increased (P 2 decreased (P 2-L4 and femoral neck BMD, estrogen, osteocalcin, and CT were negatively (P 2. PTH and CT were correlated positively and negatively with IL-6, respectively (P Conclusions The present study demonstrates that long-term aerobic exercise training plus N-3 supplementation have a synergistic effect in attenuating inflammation and augmenting BMD in post-menopausal osteoporosis.

  11. The pch2Delta mutation in baker's yeast alters meiotic crossover levels and confers a defect in crossover interference.

    Directory of Open Access Journals (Sweden)

    Sarah Zanders

    2009-07-01

    Full Text Available Pch2 is a widely conserved protein that is required in baker's yeast for the organization of meiotic chromosome axes into specific domains. We provide four lines of evidence suggesting that it regulates the formation and distribution of crossover events required to promote chromosome segregation at Meiosis I. First, pch2Delta mutants display wild-type crossover levels on a small (III chromosome, but increased levels on larger (VII, VIII, XV chromosomes. Second, pch2Delta mutants show defects in crossover interference. Third, crossovers observed in pch2Delta require both Msh4-Msh5 and Mms4-Mus81 functions. Lastly, the pch2Delta mutation decreases spore viability and disrupts crossover interference in spo11 hypomorph strains that have reduced levels of meiosis-induced double-strand breaks. Based on these and previous observations, we propose a model in which Pch2 functions at an early step in crossover control to ensure that every homolog pair receives an obligate crossover.

  12. Random-effects linear modeling and sample size tables for two special crossover designs of average bioequivalence studies: the four-period, two-sequence, two-formulation and six-period, three-sequence, three-formulation designs.

    Science.gov (United States)

    Diaz, Francisco J; Berg, Michel J; Krebill, Ron; Welty, Timothy; Gidal, Barry E; Alloway, Rita; Privitera, Michael

    2013-12-01

    Due to concern and debate in the epilepsy medical community and to the current interest of the US Food and Drug Administration (FDA) in revising approaches to the approval of generic drugs, the FDA is currently supporting ongoing bioequivalence studies of antiepileptic drugs, the EQUIGEN studies. During the design of these crossover studies, the researchers could not find commercial or non-commercial statistical software that quickly allowed computation of sample sizes for their designs, particularly software implementing the FDA requirement of using random-effects linear models for the analyses of bioequivalence studies. This article presents tables for sample-size evaluations of average bioequivalence studies based on the two crossover designs used in the EQUIGEN studies: the four-period, two-sequence, two-formulation design, and the six-period, three-sequence, three-formulation design. Sample-size computations assume that random-effects linear models are used in bioequivalence analyses with crossover designs. Random-effects linear models have been traditionally viewed by many pharmacologists and clinical researchers as just mathematical devices to analyze repeated-measures data. In contrast, a modern view of these models attributes an important mathematical role in theoretical formulations in personalized medicine to them, because these models not only have parameters that represent average patients, but also have parameters that represent individual patients. Moreover, the notation and language of random-effects linear models have evolved over the years. Thus, another goal of this article is to provide a presentation of the statistical modeling of data from bioequivalence studies that highlights the modern view of these models, with special emphasis on power analyses and sample-size computations.

  13. Perfusion CT measurements in healthy cervical spinal cord: feasibility and repeatability of the study as well as interchangeability of the perfusion estimates using two commercially available software packages

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [Johann Wolfgang University Hospital, Department of Radiology, Frankfurt (Germany); Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Johann Wolfgang Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Rumboldt, Zoran; Deveikis, John; Spampinato, Maria Vittoria [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Surlan, Katarina [Clinical Centre Ljubljana, Department of Clinical Radiology, Ljubljana (Slovenia); Koh, Tong San [Nanyang Technological University, School of Electrical and Electronic Engineering, Singapore (Singapore)

    2008-10-15

    Our purpose was to examine the feasibility and reproducibility of perfusion CT studies in the cervical spinal cord and the interchangeability of the values obtained by two post-processing methods. The perfusion CT studies of 40 patients with neck tumours were post-processed using two software packages (Software-1: deconvolution-based analysis with adiabatic tissue homogeneity approach and Software-2: maximum-slope-model with Patlak analysis). Eight patients were examined twice for assessing the reproducibility of the technique. Two neuroradiologists separately post-processed the images with two arterial input functions (AIFs): (1) the internal carotid artery (ICA) and (2) the vertebral artery (VA). Maps of blood flow (F) in ml/min/100 g, blood volume (V) in ml/100 g, mean transit time (MTT) in seconds (s) and permeability (PS) in ml/min/100 g were generated. The mean F, V, MTT and PS (Software-1) with VA-AIF and ICA-AIF were 8.93, 1.12, 16.3, 1.88 and 8.57, 1.19, 16.85 and 1.94, respectively. The reproducibility of the techniques was satisfactory, while the V and MTT values (in Software-1) and the F and V values (in Software-2) were dependent on the site of the AIF (p{>=}0.03 and p=0.02, respectively). The interobserver agreement was very good. The significant differences in measurements for a single patient (%) using Software-1/Software-2 were {+-}120%/110%, 90%/80%, 180% and 250%/130% for F, V, MTT and PS, respectively. Only F and PS values in the healthy tissue seemed to be interchangeable. Our results were in essential agreement with those derived by invasive measurements in animals. The cervical spine perfusion CT studies are feasible and reproducible. The present knowledge has to be validated with studies in spinal cord tumours in order to decide the usefulness of the perfusion CT in this field. (orig.)

  14. Microelectromechanical systems integrating molecular spin crossover actuators

    Science.gov (United States)

    Manrique-Juarez, Maria D.; Rat, Sylvain; Mathieu, Fabrice; Saya, Daisuke; Séguy, Isabelle; Leïchlé, Thierry; Nicu, Liviu; Salmon, Lionel; Molnár, Gábor; Bousseksou, Azzedine

    2016-08-01

    Silicon MEMS cantilevers coated with a 200 nm thin layer of the molecular spin crossover complex [Fe(H2B(pz)2)2(phen)] (H2B(pz)2 = dihydrobis(pyrazolyl)borate and phen = 1,10-phenantroline) were actuated using an external magnetic field and their resonance frequency was tracked by means of integrated piezoresistive detection. The light-induced spin-state switching of the molecules from the ground low spin to the metastable high spin state at 10 K led to a well-reproducible shift of the cantilever's resonance frequency (Δfr = -0.52 Hz). Control experiments at different temperatures using coated as well as uncoated devices along with simple calculations support the assignment of this effect to the spin transition. This latter translates into changes in mechanical behavior of the cantilever due to the strong spin-state/lattice coupling. A guideline for the optimization of device parameters is proposed so as to efficiently harness molecular scale movements for large-scale mechanical work, thus paving the road for nanoelectromechanical systems (NEMS) actuators based on molecular materials.

  15. Standard Model thermodynamics across the electroweak crossover

    Energy Technology Data Exchange (ETDEWEB)

    Laine, M.; Meyer, M. [Institute for Theoretical Physics, Albert Einstein Center, University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2015-07-22

    Even though the Standard Model with a Higgs mass m{sub \\tiny H}=125 GeV possesses no bulk phase transition, its thermodynamics still experiences a “soft point” at temperatures around T=160 GeV, with a deviation from ideal gas thermodynamics. Such a deviation may have an effect on precision computations of weakly interacting dark matter relic abundances if their mass is in the few TeV range, or on leptogenesis scenarios operating in this temperature range. By making use of results from lattice simulations based on a dimensionally reduced effective field theory, we estimate the relevant thermodynamic functions across the crossover. The results are tabulated in a numerical form permitting for their insertion as a background equation of state into cosmological particle production/decoupling codes. We find that Higgs dynamics induces a non-trivial “structure” visible e.g. in the heat capacity, but that in general the largest radiative corrections originate from QCD effects, reducing the energy density by a couple of percent from the free value even at T>160 GeV.

  16. Dimensional crossover in Richtmyer-Meshkov flows

    Science.gov (United States)

    Nishihara, Katsunobu; Bhowmick, Aklant K.; Abarzhi, Snezhana

    2016-11-01

    We analyze nonlinear dynamics of large scale coherent structures in Richtmyer-Meshkov flows. Group theory based analysis is applied with a detailed consideration of RM dynamics invariant with respect to p2mm (3D rectangular), p4mm (3D square) and pm1 (2D) groups. Symmetry dictates that asymptotic solutions form a 2 parameter family for rectangular flows and a 1 parameter family for 3D square and 2D flows. For 3D square and 2D symmetry, asymptotic solutions are obtained for the 1st and 2nd order of approximation and the fastest growth rate occurs at zero bubble curvatures. Fourier amplitudes exponentially decay with increase in order showing that solutions are convergent. Both 2D and 3D square solutions are stable with respect to symmetry conserving perturbations. Isotropic 3D square solutions are universally stable, while 2D solutions are unstable to anisotropic perturbations. Furthermore, the 3D and 2D solutions cannot be continuously transformed from one to another, and the dimensional crossover is discontinuous. The work is supported by the US National Science Foundation.

  17. Evaluation of repeated measurements of radon-222 concentrations in well water sampled from bedrock aquifers of the Piedmont near Richmond, Virginia, USA: effects of lithology and well characteristics.

    Science.gov (United States)

    Harris, Shelley A; Billmeyer, Ernest R; Robinson, Michael A

    2006-07-01

    Radon (222Rn) concentrations in 26 ground water wells of two distinct lithologies in the Piedmont of Virginia were measured to assess variation in ground water radon concentrations (GWRC), to evaluate differences in concentrations related to well characteristics, lithology, and spatial distributions, and to assess the feasibility of predicting GWRC. Wells were sampled in accordance with American Public Health Association Method 7500 Rn-B, with modifications to include a well shaft profile analysis that determined the minimum purge time sufficient to remove the equivalent of one column of water from each well. Statistically significant differences in GWRC were found in the Trssu (1482 +/- 1711 pCi/L) and Mpg (7750 +/- 5188 pCi/L) lithologies, however, no significant differences were found among GWRC at each well over time. Using multiple regression, 86% of the variability (R2) in the GWRC was explained by the lithology, latitudinal class, and water table elevation of the wells. The GWRC in a majority of the wells studied exceed US Environmental Protection Agency designated maximum contaminant level and AMCL. Results support modifications to sampling procedures and indicate that, in previous studies, variations in GWRC concentrations over time may have been due in part to differences in sampling procedures and not in source water.

  18. The Effect of Plastic Cover on Regulation of Vital Signs in Preterm Infants: A Randomized Cross-over Clinical Trial

    Directory of Open Access Journals (Sweden)

    Leila Valizadeh

    2017-06-01

    Full Text Available Background: Considering the susceptibility of preterm infants to disturbances of vital signs, this study was conducted to investigate the effects of using plastic covers on regulation of vital signs in preterm neonates.Methods: This randomized, cross-over, clinical trial was carried out on 80 preterm infants admitted to neonatal intensive care unit (NICU of Taleghani Hospital, Tabriz, Iran. The study was conducted in two days (on the second and third days of the infants’ life. In group 1, plastic cover was used during the first day followed by the use of blanket on the second day, while the order was reversed in group 2. Digital thermometer was used to measure the infants’ axillary temperature. Heart rate and oxygen saturation were measured through monitoring. To analyze the data, descriptive (Mean and SE, 95%CI and inferential statistics (repeated measurement and ANCOVA tests were used in SPSS version 13 and MiniTab software.Results: Fourteen infants who were covered with blanket were found to suffer from hypothermia, while no infant with a plastic cover encountered this problem. The percentage of arterial blood oxygen saturation in the group with plastic covers was higher, and as a result, the infants received less oxygen supplements. However, no statistically significant differences were observed in heart rate between the groups.Conclusion: Use of plastic cover during NICU stay prevented hypothermia in premature infants, with the arterial blood oxygen saturation being within the normal limits. Yet, it did not seem to have a significant effect on other vital signs.

  19. Viscosity of liquid Ag-In-Sb-Te: Evidence of a fragile-to-strong crossover

    Science.gov (United States)

    Orava, J.; Weber, H.; Kaban, I.; Greer, A. L.

    2016-05-01

    The temperature-dependent viscosity η(T) is measured for the equilibrium liquid of the chalcogenide Ag-In-Sb-Te (AIST), the first time this has been reported for a material of actual interest for phase-change memory. The measurements, in the range 829-1254 K, are made using an oscillating-crucible viscometer, and show a liquid with high fragility and low viscosity, similar to liquid pure metals. Combining the high-temperature viscosity measurements with values inferred from crystal growth rates in the supercooled liquid allows the form of η(T) to be estimated over the entire temperature range from above the melting point down to the glass transition. It is then clear that η(T) for liquid AIST cannot be described with a single fragility value, unlike other phase-change chalcogenides such as liquid Ge-Sb-Te. There is clear evidence for a fragile-to-strong crossover on cooling liquid AIST, similar to that analyzed in Te85Ge15. The change in fragility associated with the crossover in both these cases is rather weak, giving a broad temperature range over which η(T) is near-Arrhenius. We discuss how such behavior may be beneficial for the performance of phase-change memory. Consideration of the fragile-to-strong crossover in liquid chalcogenides may be important in tuning compositions to optimize the device performance.

  20. New Variations of Order Crossover for Travelling Salesman Problem

    Directory of Open Access Journals (Sweden)

    Kusum Deep

    2011-01-01

    Full Text Available Davis presented the order crossover operator for solving the travelling salesman problem (TSP using genetic algorithm and has described two basic variants of this order crossover operator. In order to improve the efficiency and validity of these variants, in this paper three new variations of the order crossover operator are presented. These are programmed in C++ and implemented on a set of benchmark test problems taken from TSPLIB.The analysis of results based on the numerical and graphical analysis indicated that the new variations of the order crossover proposed in this paper have a definite supremacy over the existing variants for TSP with number of cities less than or equal to 100 as well as greater than 100 for some instances.

  1. Variant of partially mapped crossover for the Travelling Salesman problems

    Directory of Open Access Journals (Sweden)

    Kusum Deep

    2012-01-01

    Full Text Available In this paper a variant of partially mapped crossover (VPMX is designed using cut point positions and is tested for its performance with the existing partially mapped crossover (PMX.In order to test the performance ,two mutation operators are used. These mutation operators are inverted displacement and inversion mutations. Partially mapped crossover (PMX with inversion and with inverted displacement and a variant of partially mapped crossover (VPMX with inversion and with inverted displacement are programmed in C++ and implemented on a set of ten benchmark problems taken from the Travelling salesman problem library (TSPLIB. The results indicate that the designed variant of PMX is superior by showing a better performance in eight instances in combination with the inverted displacement mutation. In two instances PMX has obtained a better result. One is PMX with inversion mutation and the other is PMX with inverted displacement mutation.

  2. Hysteretic behavior of spin-crossover noise driven system

    Energy Technology Data Exchange (ETDEWEB)

    Gudyma, Iurii [Department of General Physics, Chernivtsi National University, Chernivtsi 58012 (Ukraine); Maksymov, Artur, E-mail: maxyartur@gmail.com [Department of General Physics, Chernivtsi National University, Chernivtsi 58012 (Ukraine); Advanced Materials Research Institute, University of New Orleans, LA 70148 (United States); Dimian, Mihai [Department of Electrical and Computer Engineering, Howard University, Washington DC, 20059 (United States); Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University, Suceava 720229 (Romania)

    2016-04-01

    The influence of white Gaussian noise on hysteretic behavior of spin-crossover system is analyzed in the framework of stochastic Langevin dynamics. Various stochastic simulations are performed and several important properties of spin-transition in spin-crossover system driven by noise are reproduced. The numerical results are tested against the stationary probability function and the associated dynamic potential obtained from Fokker–Planck equation corresponding to spin-crossover Langevin dynamics. The dependence of light-induced optical hysteresis width and non-hysteretic transition curve slope on the noise intensity is illustrated. The role of low-spin and high-spin phase stabilities in the hysteretic behavior of noise-driven spin-crossover system is discussed.

  3. Electronic bidirectional valve circuit prevents crossover distortion and threshold effect

    Science.gov (United States)

    Kernick, A.

    1966-01-01

    Four-terminal network forms a bidirectional valve which will switch or alternate an ac signal without crossover distortion or threshold effect. In this network, an isolated control signal is sufficient for circuit turn-on.

  4. Relative contributions of interface pressure, shear stress, and temperature on ischemic-induced, skin-reactive hyperemia in healthy volunteers: a repeated measures laboratory study.

    Science.gov (United States)

    Lachenbruch, Charlie; Tzen, Yi-Ting; Brienza, David; Karg, Patricia E; Lachenbruch, Peter A

    2015-02-01

    Although the primary risk factors for pressure ulcer development - pressure, shear, skin temperature, moisture, and friction - have been identified for decades, the relative contribution of each to this risk remains unclear. To confirm the results of and expand upon earlier research into the relative contributions of interface pressures, shear stress, and skin temperature among 4 healthy volunteers, a study involving 6 additional healthy 40- to 75-year-old volunteers was conducted and results of the 2 studies were pooled. All 3 variables (interface pressures, shear stress, and skin temperature) were systematically and randomly varied. In the prone position, volunteers each underwent 18 test conditions representing different combinations of temperature (28˚ C, 32˚ C, 36˚ C), pressure (8.0 and 13.3 kPa), and shear (0, 6.7, and 14.0 kPa) using a computer-controlled indenter applied to the sacrum for 20 minutes exerting weights of 100 g and 200 g to induce 0.98 N and 1.96 N of shear force, respectively. Each condition was tested twice, resulting in a total of 360 trials. Magnitude of postload reactive hyperemia as an index of ischemia was measured by laser Doppler flowmetry. Fixed effects regression models were used to predict 3 different indices of reactive hyperemic magnitude. Friedman tests were performed to compare the reactive hyperemia among 3 different skin temperatures or shear stresses under the same amount of localized pressure. In all regression models, pressure and temperature were highly significant predictors of the extent of reactive hyperemia (P pressure and shear stress, and the difference was more profound between 32˚ C and 36˚ C than between 28˚ C and 32˚ C. These results confirm that, in laboratory settings, temperature is an important factor in tissue ischemia. Additional studies examining the relative importance of pressure, shear, and temperature and potential effects of lowering temperature on tissue ischemia in healthy volunteers and

  5. Effects of red bull energy drink on repeated sprint performance in women athletes.

    Science.gov (United States)

    Astorino, Todd A; Matera, Angela J; Basinger, Jency; Evans, Mindy; Schurman, Taylor; Marquez, Rodney

    2012-05-01

    Energy drinks are frequently consumed by athletes prior to competition to improve performance. This study examined the effect of Red Bull™ on repeated sprint performance in women athletes. Fifteen collegiate soccer players participated, with mean age, height, and body mass equal to 19.5±1.1 year, 168.4±5.8 cm, and 63.4±6.1 kg, respectively. After performing a familiarization trial, subjects performed three sets of eight bouts of the modified t test after ingestion of 255 mL of placebo or Red Bull 1 h pre-exercise in a randomized, placebo-controlled crossover design. Throughout testing, sprint time, heart rate (HR), and rating of perceived exertion (RPE) were continuously obtained. Repeated measures analysis of variance was used to examine differences in variables between drink conditions. Across athletes, t test time ranged from 10.4 to 12.7 s. Mean sprint time was similar (p>0.05) between Red Bull (11.31±0.61 s) and placebo (11.35±0.61 s). HR and RPE increased (p0.05) of Red Bull on either variable versus placebo. Findings indicate that 255 mL of Red Bull containing 1.3 mg/kg of caffeine and 1 g of taurine does not alter repeated sprint performance, RPE, or HR in women athletes versus placebo. One serving of this energy drink provides no ergogenic benefit for women athletes engaging in sprint-based exercise.

  6. Repetibilidade da mensuração de imagens das características de carcaça obtidas por ultrassonografia em fêmeas Nelore Repeatability of ultrasound image measurements of carcass traits in Nellore cattle

    Directory of Open Access Journals (Sweden)

    Maria Eugênia Zerlotti Mercadante

    2010-04-01

    Full Text Available Avaliou-se a repetibilidade da mensuração de imagens de ultrassom da área do músculo longissimus dorsi (AOL e das espessuras de gordura subcutânea do lombo (EGL e da garupa (EGG. Imagens de ultrassom tomadas no lombo (entre a 12ª e a 13ª costela e na garupa (entre os músculos gluteus medium e biceps femoris de novilhas Nelore de 14 a 22 meses de idade foram classificadas em aceitáveis, marginais e rejeitáveis. As imagens aceitáveis e marginais foram mensuradas duas vezes por três técnicos em diferentes níveis de treinamento. Foram estimadas as repetibilidades entre e dentro de técnicos por classe de qualidade da imagem, para determinação do efeito da qualidade da imagem e do técnico no valor absoluto da diferença entre a primeira e a segunda mensuração dessas características. A repetibilidade para as imagens aceitáveis foi maior que para imagens marginais, tanto entre como dentro de técnicos. Na análise da diferença absoluta entre a primeira e a segunda interpretação, foram significativos os efeitos de técnico para AOL e EGL e de classe de qualidade da imagem para AOL. Em geral, o técnico com maior experiência apresentou maiores valores de repetibilidade. É recomendável que a mensuração de imagens de animais de mesmo grupo contemporâneo seja feita por um único técnico.The repeatability of ultrasound image measurements of the longissimus dorsi muscle (AOL and of the rumpfat (EGG and backfat (EGL subcutaneous thickness was evaluated. Ultrasound images taken from the back (between 12th and 13th ribs and from the rump (between gluteus medium and biceps femoris muscles of Nelore heifers at 14 and 22 months of age were classified as acceptable, marginal and rejected. The acceptable and marginal images were measured twice by three technicians at different levels of training. It was estimated repeatabilities among and within technicians by class of image quality in order to determine effect of image quality and of

  7. Research Update: The mechanocaloric potential of spin crossover compounds

    Directory of Open Access Journals (Sweden)

    Karl G. Sandeman

    2016-11-01

    Full Text Available We present a first evaluation of the potential for spin crossover (SCO compounds to be considered as a new class of giant mechanocaloric effect materials. From literature data on the variation of the spin crossover temperature with pressure, we estimate the maximum available adiabatic temperature change for several compounds and the relatively low pressures that may be required to observe these effects.

  8. Crowding by a repeating pattern.

    Science.gov (United States)

    Rosen, Sarah; Pelli, Denis G

    2015-01-01

    Theinability to recognize a peripheral target among flankers is called crowding. For a foveal target, crowding can be distinguished from overlap masking by its sparing of detection, linear scaling with eccentricity, and invariance with target size.Crowding depends on the proximity and similarity of the flankers to the target. Flankers that are far from or dissimilar to the target do not crowd it. On a gray page, text whose neighboring letters have different colors, alternately black and white, has enough dissimilarity that it might escape crowding. Since reading speed is normally limited by crowding, escape from crowding should allow faster reading. Yet reading speed is unchanged (Chung & Mansfield, 2009). Why? A recent vernier study found that using alternating-color flankers produces strong crowding (Manassi, Sayim, & Herzog, 2012). Might that effect occur with letters and reading? Critical spacing is the minimum center-to-center target-flanker spacing needed to correctly identify the target. We measure it for a target letter surrounded by several equidistant flanker letters of the same polarity, opposite polarity, or mixed polarity: alternately white and black. We find strong crowding in the alternating condition, even though each flanker letter is beyond its own critical spacing (as measured in a separate condition). Thus a periodic repeating pattern can produce crowding even when the individual elements do not. Further, in all conditions we find that, once a periodic pattern repeats (two cycles), further repetition does not affect critical spacing of the innermost flanker.

  9. Repeatability of peripheral aberrations in young emmetropes.

    Science.gov (United States)

    Baskaran, Karthikeyan; Theagarayan, Baskar; Carius, Staffan; Gustafsson, Jörgen

    2010-10-01

    The purpose of this study is to assess the intrasession repeatability of ocular aberration measurements in the peripheral visual field with a commercially available Shack-Hartmann aberrometer (complete ophthalmic analysis system-high definition-vision research). The higher-order off-axis aberrations data in young healthy emmetropic eyes are also reported. The aberrations of the right eye of 18 emmetropes were measured using an aberrometer with an open field of view that allows peripheral measurements. Five repeated measures of ocular aberrations were obtained and assessed in steps of 10° out to ±40° in the horizontal visual field (nasal + and temporal -) and -20° in the inferior visual field. The coefficient of repeatability, coefficient of variation, and the intraclass correlation coefficient were calculated as a measure of intrasession repeatability. In all eccentric angles, the repeatability of the third- and fourth-order aberrations was better than the fifth and sixth order aberrations. The coefficient of variation was coefficient was >0.90 for the third and fourth order but reduced gradually for higher orders. There was no statistical significant difference in variance of total higher-order root mean square between on- and off-axis measurements (p > 0.05). The aberration data in this group of young emmetropes showed that the horizontal coma (C(3)(1)) was most positive at 40° in the temporal field, decreasing linearly toward negative values with increasing off-axis angle into the nasal field, whereas all other higher-order aberrations showed little or no change. The complete ophthalmic analysis system-high definition-vision research provides fast, repeatable, and valid peripheral aberration measurements and can be used efficiently to measure off-axis aberrations in the peripheral visual field.

  10. Crossovers from parity conserving to directed percolation universality.

    Science.gov (United States)

    Odor, Géza; Menyhárd, Nóra

    2008-10-01

    The crossover behavior of various models exhibiting phase transition to absorbing phase with parity conserving class has been investigated by numerical simulations and cluster mean-field method. In case of models exhibiting Z_2 symmetric absorbing phases (the cellular automaton version of the nonequilibrium kinetic Ising model (NEKIMCA) and a stochastic cellular automaton invented by Grassberger, Krause, and von der Twer [J. Phys. A 17, L105 (1984)]) the introduction of an external symmetry breaking field causes a crossover to kink parity conserving models characterized by dynamical scaling of the directed percolation (DP) and the crossover exponent: 1/phi approximately equal to 0.53(2) . In the case of a branching and annihilating random walk model with an even number of offspring (dual to NEKIMCA) the introduction of spontaneous particle decay destroys the parity conservation and results in a crossover to the DP class characterized by the crossover exponent: 1/phi approximately equal to 0.205(5) . The two different kinds of crossover operators cannot be mapped onto each other and the resulting models show a diversity within the DP universality class in one dimension. These subclasses differ in cluster scaling exponents.

  11. Structural crossover in a supercooled metallic liquid and the link to a liquid-to-liquid phase transition

    Science.gov (United States)

    Lan, S.; Blodgett, M.; Kelton, K. F.; Ma, J. L.; Fan, J.; Wang, X.-L.

    2016-05-01

    Time-resolved synchrotron measurements were carried out to capture the structure evolution of an electrostatically levitated metallic-glass-forming liquid during free cooling. The experimental data shows a crossover in the liquid structure at ˜1000 K, about 115 K below the melting temperature and 150 K above the crystallization temperature. The structure change is characterized by a dramatic growth in the extended-range order below the crossover temperature. Molecular dynamics simulations have identified that the growth of the extended-range order was due to an increased correlation between solute atoms. These results provide structural evidence for a liquid-to-liquid-phase-transition in the supercooled metallic liquid.

  12. An enhancement of selection and crossover operations in real-coded genetic algorithm for large-dimensionality optimization

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Noh Sung; Lee, Jongsoo [Yonsei University, Seoul (Korea, Republic of)

    2016-01-15

    The present study aims to implement a new selection method and a novel crossover operation in a real-coded genetic algorithm. The proposed selection method facilitates the establishment of a successively evolved population by combining several subpopulations: an elitist subpopulation, an off-spring subpopulation and a mutated subpopulation. A probabilistic crossover is performed based on the measure of probabilistic distance between the individuals. The concept of ‘allowance’ is suggested to describe the level of variance in the crossover operation. A number of nonlinear/non-convex functions and engineering optimization problems are explored to verify the capacities of the proposed strategies. The results are compared with those obtained from other genetic and nature-inspired algorithms.

  13. Fabrication of YBCO/CeO{sub 2}/YBCO crossover and via structures for digital circuit and integrated SQUID applications

    Energy Technology Data Exchange (ETDEWEB)

    Tsukamoto, A.; Fukazawa, T.; Soutome, Y.; Tarutani, Y.; Takagi, K. [Hitachi Ltd Advanced Research Laboratory, Kokubunji, Tokyo 185-8601 (Japan)

    1999-11-01

    We have developed a multilayer process for fabricating crossover and via structures. A crossover structure with T{sub c}>85 K was fabricated by using an SrTiO{sub 3} buffer layer to repair the SrTiO{sub 3} surface damaged during etching. The interlayer resistance of a 10 {mu}m x 50 {mu}m crossover area was 150 k{omega}. Via contacts fabricated under various process conditions all showed residual resistance with reduced T{sub c}, indicating the formation of damaged layers at the contact interfaces. However, the I{sub c} measured through the via contacts fabricated under the optimal conditions exceeded 3 mA at 77 K which was high enough for most superconducting device applications. (author)

  14. Acute effects of pea protein and hull fibre alone and combined on blood glucose, appetite, and food intake in healthy young men--a randomized crossover trial.

    Science.gov (United States)

    Mollard, Rebecca C; Luhovyy, Bohdan L; Smith, Christopher; Anderson, G Harvey

    2014-12-01

    Whether pulse components can be used as value-added ingredients in foods formulated for blood glucose (BG) and food intake (FI) control requires investigation. The objective of this study was to examine of the effects of pea components on FI at an ad libitum meal, as well as appetite and BG responses before and after the meal. In a repeated-measures crossover trial, men (n = 15) randomly consumed (i) pea hull fibre (7 g), (ii) pea protein (10 g), (iii) pea protein (10 g) plus hull fibre (7 g), (iv) yellow peas (406 g), and (v) control. Pea hull fibre and protein were served with tomato sauce and noodles, while yellow peas were served with tomato sauce. Control was noodles and tomato sauce. FI was measured at a pizza meal (135 min). Appetite and BG were measured pre-pizza (0-135 min) and post-pizza (155-215 min). Protein plus fibre and yellow peas led to lower pre-pizza BG area under the curve compared with fibre and control. At 30 min, BG was lower after protein plus fibre and yellow peas compared with fibre and control, whereas at 45 and 75 min, protein plus fibre and yellow peas led to lower BG compared with fibre (p peas led to lower BG compared with fibre (p pea components as value-added ingredients in foods designed to improve glycemic control.

  15. Crossover Leung-Griffiths model and the phase behavior of dilute aqueous ionic solutions

    Science.gov (United States)

    Belyakov, M. Yu.; Kiselev, S. B.; Rainwater, J. C.

    1997-08-01

    A new parametric crossover model for the phase behavior of a binary mixture is presented that corresponds to the Leung-Griffiths model in the critical region and is transformed into the regular classical expansion far away from the critical point. The model is optimized to, and leads to excellent agreement with, isothermal vapor-liquid equilibrium data for dilute aqueous solutions of sodium chloride by Bischoff and co-workers. It then accurately predicts constant-composition phase equilibrium loci as measured by independent workers. This crossover model is therefore capable of representing the thermodynamic surface of ionic solutions in a large range of temperatures and densities around the critical points of vapor-liquid equilibrium.

  16. Electrically controllable molecular spin crossover switching in Fe(phen)2 (NCS)2 thin film

    Science.gov (United States)

    Mondal, Chaitali; Mandal, Swapan K.

    2016-10-01

    Spin crossover molecular complex Fe(phen)2(NCS)2 in thin film form (20-300 nm) is obtained by simple dip-coating technique on glass substrates. The growth of the molecular films is confirmed by optical and X-ray diffraction data. The morphology of the samples shows distributed nanocrystals with an average size ca. 12 nm. We measure the current (I)-voltage (V) characteristics of a device with 300 nm film thickness and show that application of electric field can induce spin state switching. The electric field experienced by individual nanocrystals separated by nanometric gap is supposed to be quite high and is plausibly playing the crucial role in instigating switching in molecular nanocrystals. The result is quite significant towards developing room temperature molecular spin cross-over switching devices in the nanoscale limit.

  17. A case-crossover study of transient risk factors influence on occupational injuries

    DEFF Research Database (Denmark)

    Oesterlund, Anna H; Lander, Flemming; Lauritsen, Jens

    2016-01-01

    BACKGROUND: The occupational injury incident rate remains relatively high in the European Union. The case-crossover study gives a unique opportunity to study transient risk factors that normally would be very difficult to approach. Studies like this have been carried out in both America and Asia......, but so far no relevant research has been conducted in Europe. METHOD: Case-crossover studies of occupational injuries were collected from PubMed and Embase and read through. Previous experiences concerning method, exposure and outcome, time-related measurements and construction of the questionnaire were...... taken into account in the preparation of a pilot study. Consequently, experiences from the pilot study were used to design the study protocol. Approximately 2000 patients with an occupational injury will be recruited from the emergency departments in Herning and Odense, Denmark. A standardised...

  18. Polymorphism in the spin-crossover ferric complexes [(TPA)Fe(III)(TCC)]PF6.

    Science.gov (United States)

    Collet, Eric; Boillot, Marie Laure; Hebert, Johan; Moisan, Nicolas; Servol, Marina; Lorenc, Maciej; Toupet, Loïc; Buron-Le Cointe, Marylise; Tissot, Antoine; Sainton, Joelle

    2009-08-01

    We have identified two polymorphs of the molecular complex [(TPA)Fe((III))(TCC)]PF(6) [TPA = tris(2-pyridylmethyl)amine and TCC = 3,4,5,6-tetrachlorocatecholate dianion]: one is monoclinic and the other is orthorhombic. By lowering the temperature both undergo a thermal spin-crossover between a high-spin (S = 5/2) and a low-spin (S = 1/2) state, which we detected by magnetic, optical and X-ray diffraction measurements. The thermal crossover is only slightly shifted between the polymorphs. Their crystalline structures consist of similar cation layers alternating with PF(6) anion layers, packed differently in the two polymorphs. The magnetic and optical properties of the polymorphs are presented.

  19. The dynamical crossover in attractive colloidal systems

    Energy Technology Data Exchange (ETDEWEB)

    Mallamace, Francesco [Dipartimento di Fisica e Scienze della Terra, Università di Messina and CNISM, I-98168 Messina (Italy); Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Corsaro, Carmelo [Dipartimento di Fisica e Scienze della Terra, Università di Messina and CNISM, I-98168 Messina (Italy); Stanley, H. Eugene [Center for Polymer Studies and Department of Physics, Boston University, Boston, Massachusetts 02215 (United States); Mallamace, Domenico [Dipartimento di Scienze dell’Ambiente, della Sicurezza, del Territorio, degli Alimenti e della Salute, Università di Messina, I-98166 Messina (Italy); Chen, Sow-Hsin [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2013-12-07

    We study the dynamical arrest in an adhesive hard-sphere colloidal system. We examine a micellar suspension of the Pluronic-L64 surfactant in the temperature (T) and volume fraction (ϕ) phase diagram. According to mode-coupling theory (MCT), this system is characterized by a cusp-like singularity and two glassy phases: an attractive glass (AG) phase and a repulsive glass (RG) phase. The T − ϕ phase diagram of this system as confirmed by a previous series of scattering data also exhibits a Percolation Threshold (PT) line, a reentrant behavior (AG-liquid-RG), and a glass-to-glass transition. The AG phase can be generated out of the liquid phase by using T and ϕ as control parameters. We utilize viscosity and nuclear magnetic resonance (NMR) techniques. NMR data confirm all the characteristic properties of the colloidal system phase diagram and give evidence of the onset of a fractal-like percolating structure at a precise threshold. The MCT scaling laws used to study the shear viscosity as a function of ϕ and T show in both cases a fragile-to-strong liquid glass-forming dynamic crossover (FSC) located near the percolation threshold where the clustering process is fully developed. These results suggest a larger thermodynamic generality for this phenomenon, which is usually studied only as a function of the temperature. We also find that the critical values of the control parameters, coincident with the PT line, define the locus of the FSC. In the region between the FSC and the glass transition lines the system dynamics are dominated by clustering effects. We thus demonstrate that it is possible, using the conceptual framework provided by extended mode-coupling theory, to describe the way a system approaches dynamic arrest, taking into account both cage and hopping effects.

  20. 超高分辨率OCT角膜上皮厚度自动测量的重复性研究%Study of repeatability of corneal epithelium thickness profiles automatically measured by ultra -high resolution OCT system

    Institute of Scientific and Technical Information of China (English)

    徐肃仲; 叶欣杰; 许哲; 杨纯; 沈梅晓

    2013-01-01

    目的:研究基于自动分层算法的超高分辨率谱域 OCT ( UHR-OCT)用于角膜上皮厚度测量的重复性。  方法:使用自行搭建的UHR-OCT系统采集18例健康受试者(年龄23.2±0.9岁)左眼的图像,应用一种基于轴向梯度信息和最短路径的分层算法对得到的SD-OCT图像进行边界探测获取角膜上皮厚度。  结果:自动与手动的上皮分层的位置有很好的相关性(P>0.05,配对t检验)。自动算法获取的6 mm范围平均上皮厚度为52.1±2.1μm,范围从50.3±1.8μm 到53.2±2.4μm,与手动分层之间的角膜上皮厚度差异为0.4±0.3μm。UHR-OCT自动算法重复测量上皮厚度的组内相关系数ICC和可重复性系数CoR分别为0.90±0.05,1.44±0.01μm。  结论:对于超高分辨率OCT,自动分层方法在角膜上皮厚度测量中有着很好的准确性和可重复性。%AIM:To assess the repeatability of thickness profiles of corneal epithelium produced by aautomatic hierarchic algorithm that was applied to images obtained by a custom-built ultra-high resolution OCT ( UHR-OCT ) system. METHODS:Eighteen left eyes of 18 subjects (23.2±0.9) years;mean age±standard deviation) were imaged twice on non-consecutive days by a custom-built ultra-high resolution OCT ( UHR -OCT ) system. A hierarchic algorithm based on the axial gradient information and a shortest path search was developed to measure the corneal epithelial thickness profiles from the SD-OCT images. RESULTS: There was good correlation between theautomatic and manual hierarchy positions of the epithelium ( p >0.05, paired t -test ). The average epithelial thickness of the 6mm central corneal region determined by the automatic hierarchic algorithm was 52.1±2.1μm, ranging from 50.3 ±1.8μm to 53.2 ±2.4μm along the horizontal meridian. The epithelial thickness differences between automatic and manual hierarchy by the UHR-OCT systems were 0.4 ±0

  1. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-01-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  2. Homeopathy for mental fatigue: lessons from a randomized, triple blind, placebo-controlled cross-over clinical trial

    Directory of Open Access Journals (Sweden)

    Dean Michael

    2012-10-01

    Full Text Available Abstract Background Difficulty in controlling attention can lead to mental fatigue in the healthy population. We identified one trial reporting a benefit in patients’ attention using a homeopathic formula preparation. One component of the preparation was potassium phosphate, widely available off the shelf as Kali phos 6x for cognitive problems. The aim of this exploratory trial was to assess the effectiveness of Kali phos 6x for attention problems associated with mental fatigue. Methods We recruited student and staff volunteers (University of York with self-reported mental fatigue, excluding any using homeopathy or prescribed stimulants, or with a diagnosis of chronic fatigue syndrome. In a triple blind, cross-over, placebo-controlled clinical trial, 86 volunteers were randomized to receive Kali phos 6x or identical placebo 10 minutes before taking a psychological test of attention (Stroop Colour-Word Test. One week later they were crossed over and took the other preparation before repeating the test. Results We found no evidence of a treatment effect in a comparison of Kali phos 6x with placebo (Kali phos minus placebo = −1.1 (95% CI −3.0 to 0.9, P = 0.3 Stroop score units, Cohen effect size = −0.17 even when allowing for a weak period effect with accuracy scores in the second period being higher than those in the first (P = 0.05. We observed a ceiling effect in the Stroop test which undermined our ability to interpret this result. Conclusions Kali phos 6x was not found to be effective in reducing mental fatigue. A ceiling effect in our primary outcome measure meant that we could not rule out a type II error. Thorough piloting of an adequate outcome measure could have led to an unequivocal result. Current Controlled Trials ISRCTN16521161

  3. Experimental Validation of Methanol Crossover in a Three-dimensional, Two-Fluid Model of a Direct Methanol Fuel Cell

    DEFF Research Database (Denmark)

    Olesen, Anders Christian; Berning, Torsten; Kær, Søren Knudsen

    2012-01-01

    in the ionomer phase of the catalytic layer, and detailed membrane transport of methanol and water. In order to verify the models ability to predict methanol crossover, simulation results are compared with experimental measurements under different current densities along with air and methanol stoichiometries...

  4. Influence of sample preparation, temperature, light, and pressure on the two-step spin crossover mononuclear compound

    NARCIS (Netherlands)

    Bonnet, S.A.; Molnar, G.; Sanchez Costa, José; Siegler, M.A.M.; Spek, A.L.; Bousseksou, A.; Fu, W.T.; Gamez, P.; Reedijk, J.

    2009-01-01

    The three phases of the mononuclear two-step spin crossover compound [Fe(bapbpy)(NCS)2] (1) are characterized by powder X-ray diffraction, Mo¨ssbauer spectroscopy, Raman spectroscopy, calorimetry, and magnetic susceptibility measurements. Mo¨ssbauer and Raman spectroscopies confirm the results obtai

  5. Repeated Measurement of Divers’ Word Fluency.

    Science.gov (United States)

    1987-04-01

    function (Fillskov & Boll, -V 1981). One type of test with clinical significance reflects Word Fluency (Borkowski, Benton & Spreen, 1967; Lezak, 1983). Word...Fluency is "the facility to produce words that fit one or more structural, phonetic , or orthographic restrictions that are not relevant to the meaning...toxic chemical exposure (Anger, 1984) and closed head injury (Borkowski et al, 1967). Word Fluency reflects mild linguistic deficits in expressive speech

  6. The dynamic crossover in water does not require bulk water.

    Science.gov (United States)

    Turton, David A; Corsaro, Carmelo; Martin, David F; Mallamace, Francesco; Wynne, Klaas

    2012-06-14

    Many of the anomalous properties of water may be explained by invoking a second critical point that terminates the coexistence line between the low- and high-density amorphous states in the liquid. Direct experimental evidence of this point, and the associated polyamorphic liquid-liquid transition, is elusive as it is necessary for liquid water to be cooled below its homogeneous-nucleation temperature. To avoid crystallization, water in the eutectic LiCl solution has been studied but then it is generally considered that "bulk" water cannot be present. However, recent computational and experimental studies observe cooperative hydration in which case it is possible that sufficient hydrogen-bonded water is present for the essential characteristics of water to be preserved. For femtosecond optical Kerr-effect and nuclear magnetic resonance measurements, we observe in each case a fractional Stokes-Einstein relation with evidence of the dynamic crossover appearing near 220 K and 250 K respectively. Spectra obtained in the glass state also confirm the complex nature of the hydrogen-bonding modes reported for neat room-temperature water and support predictions of anomalous diffusion due to "worm-hole" structure.

  7. Thermopower of molecular junctions: Tunneling to hopping crossover in DNA

    Science.gov (United States)

    Korol, Roman; Kilgour, Michael; Segal, Dvira

    2016-12-01

    We study the electrical conductance G and the thermopower S of single-molecule junctions and reveal signatures of different transport mechanisms: off-resonant tunneling, on-resonant coherent (ballistic) motion, and multi-step hopping. These mechanisms are identified by studying the behavior of G and S while varying molecular length and temperature. Based on a simple one-dimensional model for molecular junctions, we derive approximate expressions for the thermopower in these different regimes. Analytical results are compared to numerical simulations, performed using a variant of Büttiker's probe technique, the so-called voltage-temperature probe, which allows us to phenomenologically introduce environmentally induced elastic and inelastic electron scattering effects, while applying both voltage and temperature biases across the junction. We further simulate the thermopower of GC-rich DNA sequences with mediating A:T blocks and manifest the tunneling-to-hopping crossover in both the electrical conductance and the thermopower, in accord with measurements by Li et al. [Nat. Commun. 7, 11294 (2016)].

  8. Tuning size and thermal hysteresis in bistable spin crossover nanoparticles.

    Science.gov (United States)

    Galán-Mascarós, José Ramón; Coronado, Eugenio; Forment-Aliaga, Alicia; Monrabal-Capilla, María; Pinilla-Cienfuegos, Elena; Ceolin, Marcelo

    2010-06-21

    Nanoparticles of iron(II) triazole salts have been prepared from water-organic microemulsions. The mean size of the nanoparticles can be tuned down to 6 nm in diameter, with a narrow size distribution. A sharp spin transition from the low spin (LS) to the high spin (HS) state is observed above room temperature, with a 30-40-K-wide thermal hysteresis. The same preparation can yield second generation nanoparticles containing molecular alloys by mixing triazole with triazole derivatives, or from metallic mixtures of iron(II) and zinc(II). In these nanoparticles of 10-15 nm, the spin transition "moves" towards lower temperatures, reaching a 316 K limit for the cooling down transition and maintaining a thermal hysteresis over 15-20-K-wide. The nanoparticles were characterized by dynamic light scattering, TEM, and AFM, after deposition on gold or silicon surfaces. The spin transition was characterized by magnetic susceptibility measurements and EXAFS (in solid samples after solvent removal) and also by the color change between the LS (violet) and HS (colorless) states in an organic solvent suspension. The discovery of bistable magnetic nanoparticles of 6 nm with a wide thermal hysteresis above room temperature showcases the actual possibilities of spin crossover materials for nanotechnological applications.

  9. Kangaroo mother care diminishes pain from heel lance in very preterm neonates: A crossover trial

    Directory of Open Access Journals (Sweden)

    McNaughton Kathryn

    2008-04-01

    Full Text Available Abstract Background Skin-to-skin contact, or kangaroo mother care (KMC has been shown to be efficacious in diminishing pain response to heel lance in full term and moderately preterm neonates. The purpose of this study was to determine if KMC would also be efficacious in very preterm neonates. Methods Preterm neonates (n = 61 between 28 0/7 and 31 6/7 weeks gestational age in three Level III NICU's in Canada comprised the sample. A single-blind randomized crossover design was employed. In the experimental condition, the infant was held in KMC for 15 minutes prior to and throughout heel lance procedure. In the control condition, the infant was in prone position swaddled in a blanket in the incubator. The primary outcome was the Premature Infant Pain Profile (PIPP, which is comprised of three facial actions, maximum heart rate, minimum oxygen saturation levels from baseline in 30-second blocks from heel lance. The secondary outcome was time to recover, defined as heart rate return to baseline. Continuous video, heart rate and oxygen saturation monitoring were recorded with event markers during the procedure and were subsequently analyzed. Repeated measures analysis-of-variance was employed to generate results. Results PIPP scores at 90 seconds post lance were significantly lower in the KMC condition (8.871 (95%CI 7.852–9.889 versus 10.677 (95%CI 9.563–11.792 p CI 103–142 versus 193 seconds (95%CI 158–227. Facial actions were highly significantly lower across all points in time reaching a two-fold difference by 120 seconds post-lance and heart rate was significantly lower across the first 90 seconds in the KMC condition. Conclusion Very preterm neonates appear to have endogenous mechanisms elicited through skin-to-skin maternal contact that decrease pain response, but not as powerfully as in older preterm neonates. The shorter recovery time in KMC is clinically important in helping maintain homeostasis. Trial Registration (Current

  10. Detection of crossover time scales in multifractal detrended fluctuation analysis

    Science.gov (United States)

    Ge, Erjia; Leung, Yee

    2013-04-01

    Fractal is employed in this paper as a scale-based method for the identification of the scaling behavior of time series. Many spatial and temporal processes exhibiting complex multi(mono)-scaling behaviors are fractals. One of the important concepts in fractals is crossover time scale(s) that separates distinct regimes having different fractal scaling behaviors. A common method is multifractal detrended fluctuation analysis (MF-DFA). The detection of crossover time scale(s) is, however, relatively subjective since it has been made without rigorous statistical procedures and has generally been determined by eye balling or subjective observation. Crossover time scales such determined may be spurious and problematic. It may not reflect the genuine underlying scaling behavior of a time series. The purpose of this paper is to propose a statistical procedure to model complex fractal scaling behaviors and reliably identify the crossover time scales under MF-DFA. The scaling-identification regression model, grounded on a solid statistical foundation, is first proposed to describe multi-scaling behaviors of fractals. Through the regression analysis and statistical inference, we can (1) identify the crossover time scales that cannot be detected by eye-balling observation, (2) determine the number and locations of the genuine crossover time scales, (3) give confidence intervals for the crossover time scales, and (4) establish the statistically significant regression model depicting the underlying scaling behavior of a time series. To substantive our argument, the regression model is applied to analyze the multi-scaling behaviors of avian-influenza outbreaks, water consumption, daily mean temperature, and rainfall of Hong Kong. Through the proposed model, we can have a deeper understanding of fractals in general and a statistical approach to identify multi-scaling behavior under MF-DFA in particular.

  11. [Case-crossover design: Basic essentials and applications].

    Science.gov (United States)

    Carracedo-Martínez, Eduardo; Tobías, Aurelio; Saez, Marc; Taracido, Margarita; Figueiras, Adolfo

    2009-01-01

    Case-crossover analysis is an observational epidemiological design that was proposed by Maclure in 1991 to assess whether a given intermittent or unusual exposure may have triggered an immediate short-term, acute event. The present article outlines the basics of case-crossover designs, as well as their applications and limitations. The case-crossover design is based on exclusively selecting case subjects. To calculate relative risk, exposure during the period of time prior to the event (case period) is compared against the same subject's exposure during one or more control periods. This method is only appropriate when the exposures are transient in time and have acute short-term effects. For exposures in which there is no trend, a unidirectional approach is the most frequent and consists of selecting one or more control periods prior to the case period. When the exposure displays a time trend (e.g., air pollution), a unidirectional approach will yield biased estimates, and therefore bidirectional case-crossover designs are used, which select control time intervals preceding and subsequent to that of the event. The case-crossover design is being increasingly used across a wide range of fields, including factors triggering traffic, occupational and domestic accidents and acute myocardial infarction, and those involved in air pollution and health and pharmacoepidemiology, among others. Insofar as data-analysis is concerned, case-crossover designs can generally be regarded as matched case-control studies and consequently conditional logistic regression can be applied. Lastly, this study analyzes practical examples of distinct applications of the case-crossover design.

  12. Evidence of dynamic crossover phenomena in water and other glass-forming liquids: experiments, MD simulations and theory

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S H; Zhang, Y; Lagi, M [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Chong, S H [Institute for Molecular Science, Okazaki 444-8585 (Japan); Baglioni, P [Department of Chemistry and CSGI, University of Florence, Sesto Fiorentino, I-50019 Florence (Italy); Mallamace, F, E-mail: sowhsin@mit.ed [Dipartimento di Fisica, Universita di Messina and IRCCS Neurolesi ' Bonino-Pulejo' , I-98166 Messina (Italy)

    2009-12-16

    In a recent quasi-elastic neutron scattering experiment on water confined in a Portland cement paste, we find that this 3D confined water shows a dynamic crossover phenomenon at T{sub L} = 227 +- 5 K. The DSC heat-flow scan upon cooling and an independent measurement of specific heat at constant pressure of confined water in silica gel show a prominent peak at the same temperature. We show in this paper that this type of behavior is common to many other glassy liquids, which also show the crossover temperature in coincidence with the temperature of a small specific heat peak. We also demonstrate with MD simulations that the dynamic crossover phenomenon in confined water is an intrinsic property of bulk water, and is not due to the confinement effect. Recently, an extended version of the mode coupling theory (MCT) including the hopping effect was developed. This theory shows that, instead of a structural arrest transition at T{sub C} predicted by the idealized MCT, a fragile-to-strong dynamic crossover phenomenon takes place instead at T{sub C}, confirming both the experimental and the numerical results. The coherent and incoherent alpha relaxation times can be scaled with the calculated viscosity, showing the same crossover phenomenon. We thus demonstrated with experiments, simulations and theory that a genuine change of dynamical behavior of both water and many glassy liquids happens at the crossover temperature T{sub L}, which is 10-30% higher than the calorimetric glass transition temperature T{sub g}.

  13. Mapping alternating current electroosmotic flow at the dielectrophoresis crossover frequency of a colloidal probe.

    Science.gov (United States)

    Wang, Jingyu; Wei, Ming-Tzo; Cohen, Joel A; Ou-Yang, H Daniel

    2013-07-01

    AC electroosmotic (ACEO) flow above the gap between coplanar electrodes is mapped by the measurement of Stokes forces on an optically trapped polystyrene colloidal particle. E²-dependent forces on the probe particle are selected by amplitude modulation (AM) of the ACEO electric field (E) and lock-in detection at twice the AM frequency. E²-dependent DEP of the probe is eliminated by driving the ACEO at the probe's DEP crossover frequency. The location-independent DEP crossover frequency is determined, in a separate experiment, as the limiting frequency of zero horizontal force as the probe is moved toward the midpoint between the electrodes. The ACEO velocity field, uncoupled from probe DEP effects, was mapped in the region 1-9 μm above a 28 μm gap between the electrodes. By use of variously sized probes, each at its DEP crossover frequency, the frequency dependence of the ACEO flow was determined at a point 3 μm above the electrode gap and 4 μm from an electrode tip. At this location the ACEO flow was maximal at ∼117 kHz for a low salt solution. This optical trapping method, by eliminating DEP forces on the probe, provides unambiguous mapping of the ACEO velocity field.

  14. Electronic Spin Crossover of Iron in Ferroperclase in Earth?s Lower Mantle

    Energy Technology Data Exchange (ETDEWEB)

    Lin, J F; Vanko, G; Jacobsen, S D; Iota, V; Struzhkin, V V; Prakapenka, V B; Kuznetsov, A; Yoo, C S

    2007-01-25

    Pressure-induced electronic spin-pairing transitions of iron and associated effects on the physical properties have been reported to occur in the lower-mantle ferropericlase, silicate perosvkite, and perhaps in post silicate perovskite at high pressures and room temperature. These recent results are motivating geophysicists and geodynamicists to reevaluate the implications of spin transitions on the seismic heterogeneity, composition, as well as the stability of the thermal upwellings of the Earth's lower mantle. Here we have measured the spin states of iron in ferropericlase and its crystal structure up to 95 GPa and 2000 K using a newly constructed X-ray emission spectroscopy and diffraction with the laser-heated diamond cell. Our results show that an isosymmetric spin crossover occurs over a pressure-temperature range extending from the upper part to the lower part of the lower mantle, and low-spin ferropericlase likely exists in the lowermost mantle. Although continuous changes in physical and chemical properties are expected to occur across the spin crossover, the spin crossover results in peculiar behavior in the thermal compression and sound velocities. Therefore, knowledge of the fraction of the spin states in the lower-mantle phases is thus essential to correctly evaluate the composition, geophysics, and dynamics of the Earth's lower mantle.

  15. Improved short adjacent repeat identification using three evolutionary Monte Carlo schemes.

    Science.gov (United States)

    Xu, Jin; Li, Qiwei; Li, Victor O K; Li, Shuo-Yen Robert; Fan, Xiaodan

    2013-01-01

    This paper employs three Evolutionary Monte Carlo (EMC) schemes to solve the Short Adjacent Repeat Identification Problem (SARIP), which aims to identify the common repeat units shared by multiple sequences. The three EMC schemes, i.e., Random Exchange (RE), Best Exchange (BE), and crossover are implemented on a parallel platform. The simulation results show that compared with the conventional Markov Chain Monte Carlo (MCMC) algorithm, all three EMC schemes can not only shorten the computation time via speeding up the convergence but also improve the solution quality in difficult cases. Moreover, we observe that the performances of different EMC schemes depend on the degeneracy degree of the motif pattern.

  16. A Link between Meiotic Prophase Progression and CrossoverControl

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, Peter M.; Farruggio, Alfonso P.; Dernburg, Abby F.

    2005-07-06

    During meiosis, most organisms ensure that homologous chromosomes undergo at least one exchange of DNA, or crossover, to link chromosomes together and accomplish proper segregation. How each chromosome receives a minimum of one crossover is unknown. During early meiosis in Caenorhabditis elegans and many other species, chromosomes adopt a polarized organization within the nucleus, which normally disappears upon completion of homolog synapsis. Mutations that impair synapsis even between a single pair of chromosomes in C. elegans delay this nuclear reorganization. We quantified this delay by developing a classification scheme for discrete stages of meiosis. Immunofluorescence localization of RAD-51 protein revealed that delayed meiotic cells also contained persistent recombination intermediates. Through genetic analysis, we found that this cytological delay in meiotic progression requires double-strand breaks and the function of the crossover-promoting heteroduplex HIM-14 (Msh4) and MSH-5. Failure of X chromosome synapsis also resulted in impaired crossover control on autosomes, which may result from greater numbers and persistence of recombination intermediates in the delayed nuclei. We conclude that maturation of recombination events on chromosomes promotes meiotic progression, and is coupled to the regulation of crossover number and placement. Our results have broad implications for the interpretation of meiotic mutants, as we have shown that asynapsis of a single chromosome pair can exert global effects on meiotic progression and recombination frequency.

  17. Crossover Analysis of CHANG'E-1 Laser Altimeter Data

    Science.gov (United States)

    Hu, W.; Yue, Z.; Di, K.

    2011-08-01

    This paper presents a preliminary result of crossover analysis and adjustment of Chang'E-1(CE-1) Laser Altimeter (LAM) data of the Moon for global and regional mapping applications. During the operation of Chang'E-1 from November 28, 2007 to December 4, 2008, the laser altimeter acquired 1400 orbital profiles with about 9.12 million altimetric points. In our experiment, we derived more than 1.38 million crossovers from 1395 ground tracks covering the entire lunar surface after eliminating outliers of orbits and altimetric points. A method of least-squares crossover adjustment with a series of basis functions of time (trigonometric functions and polynomials) is developed to reconcile the LAM data by minimizing the crossover residuals globally. The normal equations are very large but sparse; therefore they are stored and solved using sparse matrix technique. In a test area (0°N~60°N, 50°W~0°W), the crossover residuals are reduced from 62.1m to 32.8m, and the quality of the DEM generated from the adjusted LAM data is improved accordingly. We will optimize the method for the global adjustment to generate a high precision consistent global DEM, which can be used as absolute control for lunar mapping with orbital images.

  18. A link between meiotic prophase progression and crossover control.

    Directory of Open Access Journals (Sweden)

    Peter M Carlton

    2006-02-01

    Full Text Available During meiosis, most organisms ensure that homologous chromosomes undergo at least one exchange of DNA, or crossover, to link chromosomes together and accomplish proper segregation. How each chromosome receives a minimum of one crossover is unknown. During early meiosis in Caenorhabditis elegans and many other species, chromosomes adopt a polarized organization within the nucleus, which normally disappears upon completion of homolog synapsis. Mutations that impair synapsis even between a single pair of chromosomes in C. elegans delay this nuclear reorganization. We quantified this delay by developing a classification scheme for discrete stages of meiosis. Immunofluorescence localization of RAD-51 protein revealed that delayed meiotic cells also contained persistent recombination intermediates. Through genetic analysis, we found that this cytological delay in meiotic progression requires double-strand breaks and the function of the crossover-promoting heteroduplex HIM-14 (Msh4 and MSH-5. Failure of X chromosome synapsis also resulted in impaired crossover control on autosomes, which may result from greater numbers and persistence of recombination intermediates in the delayed nuclei. We conclude that maturation of recombination events on chromosomes promotes meiotic progression, and is coupled to the regulation of crossover number and placement. Our results have broad implications for the interpretation of meiotic mutants, as we have shown that asynapsis of a single chromosome pair can exert global effects on meiotic progression and recombination frequency.

  19. Verificação da prótese auditiva realizada face a face e via teleconsulta: medidas repetidas Telecounselling and face to face hearing aid verification: repeated measures

    Directory of Open Access Journals (Sweden)

    Deborah Viviane Ferrari

    2012-12-01

    Full Text Available OBJETIVO: avaliar as medidas repetidas da resposta de ressonância da orelha externa sem (REUR e com uso de amplificação (REAR e o ganho de inserção (REIG, realizados face a face e via teleconsulta. MÉTODO: estudo prospectivo longitudinal. Foram realizadas quatro repetições da REUR, REAR e REIG (com estímulo speech noise apresentado em 65 dB NPS e 0º azimute em 19 orelhas de adultos ouvintes normais, via face a face (F e teleconsulta síncrona por controle remoto de aplicativo (T e vídeo interativo. O software Polycom PVX foi utilizado para compartilhamento e transmissão de áudio e vídeo. A conexão foi realizada via LAN (Local Area Network USP na velocidade de 384 kbps Foi calculado o erro causal (Dalhberg entre as quatro medidas para frequências de 250 a 8000 Hz. RESULTADOS: os erros casuais entre as medidas F e T foram muito semelhantes, sendo maiores nas frequências acima de 4 kHz. As diferenças e variações entre as medidas F e T estavam dentro da magnitude de variabilidade do procedimento de medidas com microfone sonda. CONCLUSÃO: as medidas com microfone sonda via teleconsulta fornece resultados confiáveis e similares aos obtidos pelo procedimento padrão.PURPOSE: to evaluate the repeated measurements of the real ear unaided response (REUR, real ear aided response (REAR and insertion gain (REIG conducted as face to face (F and via telecounselling (T. METHOD: longitudinal prospective study. Four measures of REUR, REAR and REIG (carried out with speech noise stimulus presented at 65 dB SPL at 0° azimuth were obtained in 19 ears in normal hearing adults, face to face and via synchronous telecounsellings with remote control of the real ear equipment and interactive video. Polycom PVX software was used for desktop sharing and video and audio transmission. The Loca Area Network (LAN USP was used for the connection (transmission rate: 384 kbps. Dahlberg’s casual errors were calculated for obtaining the measures for

  20. Bean and rice meals reduce postprandial glycemic response in adults with type 2 diabetes: a cross-over study

    Directory of Open Access Journals (Sweden)

    Thompson Sharon V

    2012-04-01

    Full Text Available Abstract Background Around the world, beans and rice are commonly consumed together as a meal. With type 2 diabetes increasing, the effect of this traditional diet pattern on glycemic response has not been studied fully. Methods We evaluated the glycemic response of bean and rice traditional meals compared to rice alone in adults with type 2 diabetes. Seventeen men and women with type 2 diabetes controlled by metformin (n = 14 or diet/exercise (n = 3 aged 35–70 years participated in the randomized 4 × 4 crossover trial. The white long grain rice control, pinto beans/rice, black beans/rice, red kidney beans/rice test meals, matched for 50 grams of available carbohydrate, were consumed at breakfast after a 12 hour fast. Capillary blood glucose concentrations at baseline and at 30 minute intervals up to 180 minutes postprandial were collected. MANOVA for repeated measures established glucose differences between treatments. Paired t tests identified differences between bean types and the rice control following a significant MANOVA. Results Postprandial net glucose values were significantly lower for the three bean/rice treatments in contrast to the rice control at 90, 120 and 150 minutes. Incremental area under the curve values were significantly lower for the pinto and black bean/rice meals compared to rice alone, but not for kidney beans. Conclusions Pinto, dark red kidney and black beans with rice attenuate the glycemic response compared to rice alone. Promotion of traditional foods may provide non-pharmaceutical management of type 2 diabetes and improve dietary adherence with cultural groups. Trial registration Clinical Trials number NCT01241253

  1. Randomized crossover comparison of adhesively coupled colostomy pouching systems.

    Science.gov (United States)

    Berg, Kirsten; Seidler, Heidi

    2005-03-01

    Ostomy pouching systems affect well being and quality of life, making selection of the appropriate system a key element of ostomy care. Several innovative adhesively coupled, two-piece systems are on the market. They feature flexible low profiles, allowing pouch removal/replacement without changing the skin barrier or wafer. This facilitates inspection or pouch changes without disrupting peristomal skin. Because few controlled trials compare pouching system effectiveness, a prospective, randomized open-label, crossover study was conducted. Under the supervision of ostomy care nurses in six outpatient clinics in Germany, clinical performance of and patient preferences for two adhesively coupled, closed-end pouching systems were compared during normal use. One is a gelatin/pectin-based skin barrier sealed to the pouch with a company-specific adhesive coupling technology (System E); the other, a grooved base plate wafer adhesive pouch coupling system (System F). Seventeen attributes and seven end-of-study measures that included comfort, flexibility, wear time, ease of removal, and overall performance were assessed. Informed, consenting participants were randomly assigned to use one system for five skin barrier/wafer changes or up to 15 days and subsequently switched to the alternative system for a similar period. The 39 participants used a total of 1,645 pouches and 342 skin barriers. All were found safe as determined by incidence and nature of the reported peristomal skin problems, subject withdrawals, and adverse events for both systems. However, System E provided longer pouch wear times (P System E on 10 of the 17 attributes (P System Fon none. More participants preferred System E on all seven end-of-study measures, five significantly (comfort, flexibility, wear time, ease of removal, and overall performance; (P < 0.02). These participant-reported, ostomy-related outcomes underscore the importance of product evaluation and selection for persons with an ostomy.

  2. Relativistic BCS-BEC Crossover at Quark Level

    Directory of Open Access Journals (Sweden)

    Zhuang P.

    2010-10-01

    Full Text Available The non-relativistic G0G formalism of BCS-BEC crossover at finite temperature is extended to relativistic fermion systems. The theory recovers the BCS mean field approximation at zero temperature and the non-relativistic results in a proper limit. For massive fermions, when the coupling strength increases, there exist two crossovers from the weak coupling BCS superfluid to the non-relativistic BEC state and then to the relativistic BEC state. For color superconductivity at moderate baryon density, the matter is in the BCS-BEC crossover region, and the behavior of the pseudogap is quite similar to that found in high temperature superconductors.

  3. Pressure effect on hysteresis in spin-crossover solid materials

    Energy Technology Data Exchange (ETDEWEB)

    Gudyma, Iurii, E-mail: yugudyma@gmail.com [Department of General Physics, Chernivtsi National University, Chernivtsi 58012 (Ukraine); Ivashko, Victor [Department of General Physics, Chernivtsi National University, Chernivtsi 58012 (Ukraine); Dimian, Mihai [Department of Electrical and Computer Engineering, Howard University, Washington DC 20059 (United States); Faculty of Electrical Engineering and Computer Science & Integrated Center for Research, Development and Innovation in Advanced Materials, Nanotechnologies, and Distributed Systems for fabrication and control, Stefan cel Mare University, Suceava 720229 (Romania)

    2016-04-01

    A generalized microscopic Ising-like model is proposed to describe behavior of compressible spin-crossover solids with two states: low-spin and high-spin. The model was solved in mean-field approximation and shows hysteretic behavior at low energy difference between the states. We study the thermal transition between states under external hydrostatic pressure taking into account the changes in the volume of spin-crossover molecules in different states. Depending on the applied pressure, a spin-crossover system can have three types of behavior of molecular fraction in the high-spin state: hysteretic, second-order phase transition and no-phase transition. For the hysteretic regime, it is shown that the transition temperature under pressure is increased while the width of the hysteresis reduced.

  4. An Improved Genetic Algorithm with Quasi-Gradient Crossover

    Institute of Scientific and Technical Information of China (English)

    Xiao-Ling Zhang; Li Du; Guang-Wei Zhang; Qiang Miao; Zhong-Lai Wang

    2008-01-01

    The convergence of genetic algorithm is mainly determined by its core operation crossover operation. When the objective function is a multiple hump function, traditional genetic algorithms are easily trapped into local optimum, which is called premature conver gence. In this paper, we propose a new genetic algorithm with improved arithmetic crossover operation based on gradient method. This crossover operation can generate offspring along quasi-gradient direction which is the Steepest descent direction of the value of objective function. The selection operator is also simplified, every individual in the population is given an opportunity to get evolution to avoid complicated selection algorithm. The adaptive mutation operator and the elitist strategy are also applied in this algorithm. The case 4 indicates this algorithm can faster converge to the global optimum and is more stable than the conventional genetic algorithms.

  5. Influence analysis on crossover design experiment in bioequivalence studies.

    Science.gov (United States)

    Huang, Yufen; Ke, Bo-Shiang

    2014-01-01

    Crossover designs are commonly used in bioequivalence studies. However, the results can be affected by some outlying observations, which may lead to the wrong decision on bioequivalence. Therefore, it is essential to investigate the influence of aberrant observations. Chow and Tse in 1990 discussed this issue by considering the methods based on the likelihood distance and estimates distance. Perturbation theory provides a useful tool for the sensitivity analysis on statistical models. Hence, in this paper, we develop the influence functions via the perturbation scheme proposed by Hampel as an alternative approach on the influence analysis for a crossover design experiment. Moreover, the comparisons between the proposed approach and the method proposed by Chow and Tse are investigated. Two real data examples are provided to illustrate the results of these approaches. Our proposed influence functions show excellent performance on the identification of outlier/influential observations and are suitable for use with small sample size crossover designs commonly used in bioequivalence studies.

  6. Superconducting Vacuum-Gap Crossovers for High Performance Microwave Applications

    CERN Document Server

    Denis, Kevin L; Chang, Meng-Ping; Hu, Ron; U-Yen, Kongpop; Wollack, Edward

    2016-01-01

    The design and fabrication of low-loss wide-bandwidth superconducting vacuum-gap crossovers for high performance millimeter wave applications are described. In order to reduce ohmic and parasitic losses at millimeter wavelengths a vacuum gap is preferred relative to dielectric spacer. Here, vacuum-gap crossovers were realized by using a sacrificial polymer layer followed by niobium sputter deposition optimized for coating coverage over an underlying niobium signal layer. Both coplanar waveguide and microstrip crossover topologies have been explored in detail. The resulting fabrication process is compatible with a bulk micro-machining process for realizing waveguide coupled detectors, which includes sacrificial wax bonding, and wafer backside deep reactive ion etching for creation of leg isolated silicon membrane structures. Release of the vacuum gap structures along with the wax bonded wafer after DRIE is implemented in the same process step used to complete the detector fabrication

  7. Dimensional crossover of the dephasing time in disordered mesoscopic rings

    Science.gov (United States)

    Treiber, M.; Yevtushenko, O. M.; Marquardt, F.; von Delft, J.; Lerner, I. V.

    2009-11-01

    We study dephasing by electron interactions in a small disordered quasi-one-dimensional (1D) ring weakly coupled to leads. We use an influence functional for quantum Nyquist noise to describe the crossover for the dephasing time τφ(T) from diffusive or ergodic 1D (τφ-1∝T2/3,T1) to zero-dimensional (0D) behavior (τφ-1∝T2) as T drops below the Thouless energy. The crossover to 0D, predicted earlier for two-dimensional and three-dimensional systems, has so far eluded experimental observation. The ring geometry holds promise of meeting this long-standing challenge, since the crossover manifests itself not only in the smooth part of the magnetoconductivity but also in the amplitude of Altshuler-Aronov-Spivak oscillations. This allows signatures of dephasing in the ring to be cleanly extracted by filtering out those of the leads.

  8. 重复测试和不同性别对小鼠旷场行为的影响%Repeated Measurement and Sex for the Behavior in Open Field in Mice

    Institute of Scientific and Technical Information of China (English)

    陈超杰; 钟志凤; 俞昌喜

    2014-01-01

    OBJECTIVE To study the effect on the locomotory activity and anxiety-like behavior of laboratory mice by both factors of repeated measurement and sex.METHODS The total distance traveled ,total mean velocity , total parallel index,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone en-tries,the percentage of time spent in center zone and the parallel index in center zone of the female and male mice for 5 minutes were recorded and analyzed in open field test by animal video tracking analysis system ,once a day for 3 days.RESULTS In the open field test ,the indexes of the total distance traveled ,total mean velocity ,total parallel index ,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone entries ,the percent-age of time spent in center zone and the parallel index in center zone in mice showed the downtrend as the measure -ment numbers were increasing ( P0.05 ).However ,as repeating the tests ,the downtrend of these in male mice were seemly more significant than female mice ,especially in the third time measurement ,in which the mean velocity ( P<0.05 ) and parallel index ( P<0.01 ) in center zone were lower than the ones in female mice ,respectively.CONCLUSION The repeated measurement inferences the locomotory activity and interrupted the anxiety state of mice.Sex of mice does not make the behavior in open field different at the first time ,but the repeated measurement seemly more signifi-cantly affect the locomotory activity of the male mice than the female.%目的:研究重复测试和不同性别两个因素对小鼠在旷场试验中自主行为活动和焦虑行为的影响。方法通过动物视频行为分析系统,分别记录和分析雌雄小鼠5 min内在旷场中的总路程、总体平均速度、总体平行指数、中央区的路程占总路程的比例、中央区的平均速度、中央区进入次数、中央区停留时间占整体测试时间的比例和中

  9. A new crossover sine model based on trigonometric model and its application to the crossover lattice equation of state

    Science.gov (United States)

    Lee, Yongjin; Shin, Moon Sam; Kim, Hwayong

    2008-12-01

    In this study, a new crossover sine model (CSM) n was developed from a trigonometric model [M. E. Fisher, S. Zinn, and P. J. Upton, Phys. Rev. B 59, 14533 (1999)]. The trigonometric model is a parametric formulation model that is used to represent the thermodynamic variables near a critical point. Although there are other crossover models based on this trigonometric model, such as the CSM and the analytical sine model, which is an analytic formulation of the CSM, the new sine model (NSM) employs a different approach from these two models in terms of the connections between the parametric variables of the trigonometric model and thermodynamic variables. In order to test the performance of the NSM, the crossover lattice equation of state [M. S. Shin, Y. Lee, and H. Kim, J. Chem. Thermodyn. 40, 174 (2008)] was applied using the NSM for correlations of various pure fluids and fluid mixtures. The results showed that over a wide range of states, the crossover lattice fluid (xLF)/NSM yields the saturated properties of pure fluids and the phase behavior of binary mixtures more accurately than the original lattice equation of state. Moreover, a comparison with the crossover lattice equation of state using the CSM (xLF/CSM) showed that the new model presents good correlation results that are comparable to the xLF/CSM.

  10. Superradiance at the localization-delocalization crossover in tubular chlorosomes

    CERN Document Server

    Molina, Rafael A; Somoza, Alejandro; Chen, Lipeng; Zhao, Yang

    2016-01-01

    We study the effect of disorder on spectral properties of tubular chlorosomes in green sulfur bacteria Cf. aurantiacus. Employing a Frenkel-exciton Hamiltonian with diagonal and off-diagonal disorder consistent with spectral and structural studies, we analyze excitonic localization and spectral statistics of the chlorosomes. A size-dependent localization-delocalization crossover is found to occur as a function of the excitonic energy. The crossover energy region coincides with the more optically active states with maximized superradiance, and is, consequently, more conducive for energy transfer.

  11. Application of Generalised sequential crossover of languages to generalised splicing

    CERN Document Server

    Jeganathan, L; Sengupta, Ritabrata

    2009-01-01

    This paper outlines an application of iterated version of generalised sequential crossover of two languages (which in some sense, an abstraction of the crossover of chromosomes in living organisms) in studying some classes of the newly proposed generalised splicing ($GS$) over two languages. It is proved that, for $X,Y \\in \\{FIN, REG, LIN, CF, CS, RE \\}, \\sg \\in FIN$, the subclass of generalized splicing languages namely $GS(X,Y,\\sg)$, (which is a subclass of the class $GS(X,Y,FIN)$) is always regular.

  12. Optimal and safe treatment of spider leg veins measuring less than 1.5 mm on skin type IV patients, using repeated low-fluence Nd:YAG laser pulses after polidocanol injection.

    Science.gov (United States)

    Moreno-Moraga, Javier; Hernández, Esteban; Royo, Josefina; Alcolea, Justo; Isarría, M Jose; Pascu, Mihail Lucian; Smarandache, Adriana; Trelles, Mario

    2013-05-01

    Treatment of micro-veins of less than 1.5 mm with laser and with chemical sclerosis is technically challenging because of their difficulty to remedy. Laser treatment is even more difficult when dark phototypes are involved.Three groups of 30 patients each, skin type IV, and vessels measuring less than 1.5 mm in diameter, were enrolled for two treatment sessions 8 weeks apart: group A, polidocanol (POL) micro-foam injection; group B, Nd:YAG laser alone; and group C, laser after POL injection. Repeated 8-Hz low-fluence pulses, moving the hand piece over a 3-cm vein segment with an average of five laser passes maximum and with a total time irradiation of 1 s were used. Sixteen weeks after the second treatment, statistically, degree of clearance after examining photographs and patients satisfaction index, plotted on a visual analogue scale and comparing results of all three groups, results were significantly better for group C (p<0.0001). No significant differences in complications were noticed between the three groups. Efficacy of combining POL and laser proved safe and satisfactory in 96 % of patients using low-fluence laser pulses with a total cumulative energy in the 3 cm venous segment, lower than that of conventional treatment. Very few and transient complications were observed. POL foam injection followed by laser pulses is safe and efficient for vein treatment in dark-skinned patients.

  13. Talking about the cause of the failures to prohibit repeatedly for prostitution or whoring and its measures%当前卖淫嫖娼屡禁不止的原因及对策

    Institute of Scientific and Technical Information of China (English)

    冯文林

    2011-01-01

    The author was talking about the characteristics of the prostitution and whoring in current, setting forth the cause of the failures to prohibit repeatedly for the prostitution and whoring. At last, the author was putting forward to the controlling measur%随着社会主义市场经济的快速发展,许多人的思想观念受市场经济消极因素和西方资本主义腐朽思想及生活方式的影响进一步加深,卖淫嫖娼行为逐年增多,已经成为一种广泛的社会丑恶现象,严重影响到当前社会治安秩序的和谐稳定,引发一系列的问题,其危害性不可低估。政府和公安机关要加大对卖淫嫖娼行为的查处打击力度,研究如何才能减少滋生卖淫嫖娼的各种因素,加强预防和正面宣传,有针对性的开展治理,净化社会环境,维护社会和谐稳定。

  14. Automated genotyping of dinucleotide repeat markers

    Energy Technology Data Exchange (ETDEWEB)

    Perlin, M.W.; Hoffman, E.P. [Carnegie Mellon Univ., Pittsburgh, PA (United States)]|[Univ. of Pittsburgh, PA (United States)

    1994-09-01

    The dinucleotide repeats (i.e., microsatellites) such as CA-repeats are a highly polymorphic, highly abundant class of PCR-amplifiable markers that have greatly streamlined genetic mapping experimentation. It is expected that over 30,000 such markers (including tri- and tetranucleotide repeats) will be characterized for routine use in the next few years. Since only size determination, and not sequencing, is required to determine alleles, in principle, dinucleotide repeat genotyping is easily performed on electrophoretic gels, and can be automated using DNA sequencers. Unfortunately, PCR stuttering with these markers generates not one band for each allele, but a pattern of bands. Since closely spaced alleles must be disambiguated by human scoring, this poses a key obstacle to full automation. We have developed methods that overcome this obstacle. Our model is that the observed data is generated by arithmetic superposition (i.e., convolution) of multiple allele patterns. By quantitatively measuring the size of each component band, and exploiting the unique stutter pattern associated with each marker, closely spaced alleles can be deconvolved; this unambiguously reconstructs the {open_quotes}true{close_quotes} allele bands, with stutter artifact removed. We used this approach in a system for automated diagnosis of (X-linked) Duchenne muscular dystrophy; four multiplexed CA-repeats within the dystrophin gene were assayed on a DNA sequencer. Our method accurately detected small variations in gel migration that shifted the allele size estimate. In 167 nonmutated alleles, 89% (149/167) showed no size variation, 9% (15/167) showed 1 bp variation, and 2% (3/167) showed 2 bp variation. We are currently developing a library of dinucleotide repeat patterns; together with our deconvolution methods, this library will enable fully automated genotyping of dinucleotide repeats from sizing data.

  15. Quality control during repeated fryings

    Directory of Open Access Journals (Sweden)

    Cuesta, C.

    1998-08-01

    Full Text Available Most of the debate ¡s about how the slow or frequent turnover of fresh fat affects the deterioration, of fat used in frying. Then, the modification of different oils used in repeated fryings of potatoes without or with turnover of fresh oil, under similar frying conditions, was evaluated by two criteria: by measuring the total polar component isolated by column chromatography and by the evaluation of the specific compounds related to thermoxidative and hydrolytic alteration by High Performance Size Exclusion Chromatography (HPSEC. The results indicate that with frequent turnover of fresh oil, the critical level of 25% of polar material is rarely reached, and there are fewer problems with fat deterioration because the frying tended to increase the level of polar material and thermoxidative compounds (polymers and dimers of triglycerides and oxidized triglycerides in the fryer oil during the first fryings, followed by minor changes and a tendency to reach a near-steady state in successive fryings. However, in repeated frying of potatoes using a null turnover the alteration rate was higher being linear the relationship found between polar material or the different thermoxidative compounds and the number of fryings. On the other hand chemical reactions produced during deep-fat frying can be minimized by using proper oils. In addition the increased level of consumers awareness toward fat composition and its impact on human health could had an impact on the selection of fats for snacks and for industry. In this way monoenic fats are the most adequate from a nutritional point of view and for its oxidative stability during frying.

  16. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  17. Effects of Lumbosacral Manipulation on Isokinetic Strength of the Knee Extensors and Flexors in Healthy Subjects: A Randomized, Controlled, Singl