WorldWideScience

Sample records for repeated measurements show

  1. Measurement-based quantum repeaters

    CERN Document Server

    Zwerger, M; Briegel, H J

    2012-01-01

    We introduce measurement-based quantum repeaters, where small-scale measurement-based quantum processors are used to perform entanglement purification and entanglement swapping in a long-range quantum communication protocol. In the scheme, pre-prepared entangled states stored at intermediate repeater stations are coupled with incoming photons by simple Bell-measurements, without the need of performing additional quantum gates or measurements. We show how to construct the required resource states, and how to minimize their size. We analyze the performance of the scheme under noise and imperfections, with focus on small-scale implementations involving entangled states of few qubits. We find measurement-based purification protocols with significantly improved noise thresholds. Furthermore we show that already resource states of small size suffice to significantly increase the maximal communication distance. We also discuss possible advantages of our scheme for different set-ups.

  2. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  3. Whole scalp resting state EEG of oscillatory brain activity shows no parametric relationship with psychoacoustic and psychosocial assessment of tinnitus: A repeated measures study.

    Science.gov (United States)

    Pierzycki, Robert H; McNamara, Adam J; Hoare, Derek J; Hall, Deborah A

    2016-01-01

    Tinnitus is a perception of sound that can occur in the absence of an external stimulus. A brief review of electroencephalography (EEG) and magnetoencephalography (MEG) literature demonstrates that there is no clear relationship between tinnitus presence and frequency band power in whole scalp or source oscillatory activity. Yet a preconception persists that such a relationship exists and that resting state EEG could be utilised as an outcome measure for clinical trials of tinnitus interventions, e.g. as a neurophysiological marker of therapeutic benefit. To address this issue, we first examined the test-retest correlation of EEG band power measures in tinnitus patients (n = 42). Second we examined the evidence for a parametric relationship between numerous commonly used tinnitus variables (psychoacoustic and psychosocial) and whole scalp EEG power spectra, directly and after applying factor reduction techniques. Test-retest correlation for both EEG band power measures and tinnitus variables were high. Yet we found no relationship between whole scalp EEG band powers and psychoacoustic or psychosocial variables. We conclude from these data that resting state whole scalp EEG should not be used as a biomarker for tinnitus and that greater caution should be exercised in regard to reporting of findings to avoid confirmation bias. The data was collected during a randomised controlled trial registered at ClinicalTrials.gov (Identifier: NCT01541969).

  4. Measuring performance at trade shows

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2004-01-01

    Trade shows is an increasingly important marketing activity to many companies, but current measures of trade show performance do not adequately capture dimensions important to exhibitors. Based on the marketing literature's outcome and behavior-based control system taxonomy, a model is built...... that captures a outcome-based sales dimension and four behavior-based dimensions (i.e. information-gathering, relationship building, image building, and motivation activities). A 16-item instrument is developed for assessing exhibitors perceptions of their trade show performance. The paper presents evidence...

  5. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  6. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...

  7. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  8. Repeated measurement sampling in genetic association analysis with genotyping errors.

    Science.gov (United States)

    Lai, Renzhen; Zhang, Hong; Yang, Yaning

    2007-02-01

    Genotype misclassification occurs frequently in human genetic association studies. When cases and controls are subject to the same misclassification model, Pearson's chi-square test has the correct type I error but may lose power. Most current methods adjusting for genotyping errors assume that the misclassification model is known a priori or can be assessed by a gold standard instrument. But in practical applications, the misclassification probabilities may not be completely known or the gold standard method can be too costly to be available. The repeated measurement design provides an alternative approach for identifying misclassification probabilities. With this design, a proportion of the subjects are measured repeatedly (five or more repeats) for the genotypes when the error model is completely unknown. We investigate the applications of the repeated measurement method in genetic association analysis. Cost-effectiveness study shows that if the phenotyping-to-genotyping cost ratio or the misclassification rates are relatively large, the repeat sampling can gain power over the regular case-control design. We also show that the power gain is not sensitive to the genetic model, genetic relative risk and the population high-risk allele frequency, all of which are typically important ingredients in association studies. An important implication of this result is that whatever the genetic factors are, the repeated measurement method can be applied if the genotyping errors must be accounted for or the phenotyping cost is high.

  9. Induced pluripotent stem cells from patients with Huntington's disease show CAG-repeat-expansion-associated phenotypes.

    Science.gov (United States)

    2012-08-03

    Huntington's disease (HD) is an inherited neurodegenerative disorder caused by an expanded stretch of CAG trinucleotide repeats that results in neuronal dysfunction and death. Here, The HD Consortium reports the generation and characterization of 14 induced pluripotent stem cell (iPSC) lines from HD patients and controls. Microarray profiling revealed CAG-repeat-expansion-associated gene expression patterns that distinguish patient lines from controls, and early onset versus late onset HD. Differentiated HD neural cells showed disease-associated changes in electrophysiology, metabolism, cell adhesion, and ultimately cell death for lines with both medium and longer CAG repeat expansions. The longer repeat lines were however the most vulnerable to cellular stressors and BDNF withdrawal, as assessed using a range of assays across consortium laboratories. The HD iPSC collection represents a unique and well-characterized resource to elucidate disease mechanisms in HD and provides a human stem cell platform for screening new candidate therapeutics.

  10. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  11. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, Joris; Klugkist, I.G.; Schoot, Rens van de; Meeus, W.H.J.; Selfhout, Maarten; Hoijtink, Herbert

    2010-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between

  12. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, J.|info:eu-repo/dai/nl/304823031; Klugkist, I.G.|info:eu-repo/dai/nl/27330089X; Van de Schoot, R.|info:eu-repo/dai/nl/304833207; Meeus, W.H.J.|info:eu-repo/dai/nl/070442215; van Zalk, M.H.W.|info:eu-repo/dai/nl/304836214; Hoijtink, H.J.A.|info:eu-repo/dai/nl/075184427

    2009-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between groups,

  13. Analysis of repeated outcome measures from longitudinal studies

    Institute of Scientific and Technical Information of China (English)

    Yuanjia WANG; Naihua DUAN

    2011-01-01

    @@ In many clinical studies repeated measurements of an outcome are collected over time.For example,in an 8-week study of treatment for obsessive compulsive disorder,the severity of the disorder may be measured weekly using the Yale-Brown-Obsessive-Compulsive-Disorder-Scale (YBOCS).For each study participant who completes the study,there will be nine repeated measures of YBOCS (a baseline assessment plus eight assessments during the course of treatment).Such a study in which participants are followed and measured repeatedly over time is called a longitudinal study and the resulting data are called longitudinal data.

  14. Airborne Repeat Pass Interferometry for Deformation Measurements

    NARCIS (Netherlands)

    Groot, J.; Otten, M.; Halsema, E. van

    2000-01-01

    In ground engineering the need for deformation measurements is urgent. SAR interferometry can be used to measure small (sub-wavelength) deformations. An experiment to investigate this for dike deformations was set up, using the C-band SAR system PHARUS (PHased ARray Universal SAR). This paper descri

  15. Unitarity, Feedback, Interactions -- Dynamics Emergent from Repeated Measurements

    CERN Document Server

    Altamirano, Natacha; Mann, Robert B; Zych, Magdalena

    2016-01-01

    Motivated by the recent efforts to describe the gravitational interaction as a classical channel arising from continuous quantum measurements, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence (quantum Zeno effect). For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions, generalizing the lower bound of the gravitational example. However, by allowing multipartite measurements, the interactions can be induced with arbitrary low decoherence. Our results have implications for gravity-inspired decoherence models and the simple framework used in the present study can find applications in devising novel quantum control protocols, or quan...

  16. Discriminant analysis for repeated measures data: a review

    Directory of Open Access Journals (Sweden)

    Lisa Lix

    2010-09-01

    Full Text Available Discriminant analysis (DA encompasses procedures for classifying observations into groups (i.e., predictive discriminative analysis and describing the relative importance of variables for distinguishing amongst groups (i.e., descriptive discriminative analysis. In recent years, a number of developments have occurred in DA procedures for the analysis of data from repeated measures designs. Specifically, DA procedures have been developed for repeated measures data characterized by missing observations and/or unbalanced measurement occasions, as well as high-dimensional data in which measurements are collected repeatedly on two or more variables. This paper reviews the literature on DA procedures for univariate and multivariate repeated measures data, focusing on covariance pattern and linear mixed-effects models. A numeric example illustrates their implementation using SAS software.

  17. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  18. Correct use of repeated measures analysis of variance.

    Science.gov (United States)

    Park, Eunsik; Cho, Meehye; Ki, Chang-Seok

    2009-02-01

    In biomedical research, researchers frequently use statistical procedures such as the t-test, standard analysis of variance (ANOVA), or the repeated measures ANOVA to compare means between the groups of interest. There are frequently some misuses in applying these procedures since the conditions of the experiments or statistical assumptions necessary to apply these procedures are not fully taken into consideration. In this paper, we demonstrate the correct use of repeated measures ANOVA to prevent or minimize ethical or scientific problems due to its misuse. We also describe the appropriate use of multiple comparison tests for follow-up analysis in repeated measures ANOVA. Finally, we demonstrate the use of repeated measures ANOVA by using real data and the statistical software package SPSS (SPSS Inc., USA).

  19. Corticosterone stress response shows long-term repeatability and links to personality in free-living Nazca boobies.

    Science.gov (United States)

    Grace, Jacquelyn K; Anderson, David J

    2014-11-01

    The concept of "coping styles", or consistently different responses to stressors, is of broad interest in behavioral ecology and biomedicine. Two critical predictions of this concept are individual consistency of neurophysiological and behavioral responses (relative to population variability) and a negative relationship between aggression/proactivity and hypothalamic-pituitary-adrenal axis reactivity. Recent studies failed to provide strong support for these predictions, especially outside of strictly controlled conditions, and long-term measures to test the first prediction are rare. Here, we demonstrate individual repeatability across 2-3years of maximum circulating corticosterone concentration [CORT] and area under the [CORT] response curve (AUCI) during a standard capture-restraint test in wild, free-living adult Nazca boobies (Sula granti). We also show that the stress response predicts the personality traits aggression and anxiety in these birds (measured in the wild); however, the strength of these results was weak. Maximum [CORT] and AUCI showed higher repeatability between years than baseline [CORT]. After controlling breeding status, sex, mass, date sampled, and their interactions, baseline [CORT] was most closely related to personality traits, followed by AUCI, and then maximum [CORT]. The direction of these relationships depended on whether the testing context was social or non-social. [CORT] parameters had little to no relationship with cross-context plasticity in personality traits. Our results generally affirm two critical predictions of coping styles, but match the emerging trend that these relationships are weak in the wild, and may depend on testing context.

  20. Assessing agreement with repeated measures for random observers.

    Science.gov (United States)

    Chen, Chia-Cheng; Barnhart, Huiman X

    2011-12-30

    Agreement studies are often concerned with assessing whether different observers for measuring responses on the same subject or sample can produce similar results. The concordance correlation coefficient (CCC) is a popular index for assessing the closeness among observers for quantitative measurements. Usually, the CCC is used for data without and with replications based on subject and observer effects only. However, we cannot use this methodology if repeated measurements rather than replications are collected. Although there exist some CCC-type indices for assessing agreement with repeated measurements, there is no CCC for random observers and random time points. In this paper, we propose a new CCC for repeated measures where both observers and time points are treated as random effects. A simulation study demonstrates our proposed methodology, and we use vertebral body data and image data for illustrations.

  1. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  2. Measurement and repeatability of interrupter resistance in unsedated newborn infants.

    Science.gov (United States)

    Adams, A M; Olden, C; Wertheim, D; Ives, A; Bridge, P D; Lenton, J; Seddon, P

    2009-12-01

    Interrupter resistance (R(int)) is a useful measure of airway caliber in young children, but has not been well characterized in infants-in whom there are concerns about the accurate measurement of driving pressure. This study aimed to assess the feasibility and repeatability of measuring R(int) in unsedated newborn infants, and to explore alternative algorithms for calculating driving pressure. R(int) measurement was attempted in 28 healthy term newborn infants during natural sleep using the MicroRint device. Paired R(int) measurements were achieved in 24 infants, but after screening of waveforms only 15 infants had at least 5 technically acceptable waveforms on both measurements. R(int) values obtained were comparable with reported values for airflow resistance in newborns using other methods. However, the repeatability coefficient (CR) was much higher than reported values in preschool children using standard back-extrapolation algorithms, with CR 2.47 KPa L(-1) sec (unscreened) and 2.93 KPa L(-1) sec (screened). Other algorithms gave only marginally better repeatability, with all CR values over 50% of the mean R(int) value. Using current commercially available equipment, R(int) is too poorly repeatable to be a reliable measurement of airflow resistance in newborn infants. Lower deadspace equipment is needed, but anatomical and physiological factors in the infant are also important.

  3. Repeat length variation in the dopamine D4 receptor gene shows no evidence of association with schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, J.; Williams, J.; Asherson, P. [Univ. of Wales College of Medicine, Cardiff (United Kingdom)] [and others

    1994-09-15

    The D4 receptor has been shown to exist in several allelic forms reflecting variation in the number of 48 base-pair sequence repeats in the putative cytoplasmic loop. We report a comparison of repeat length variation between schizophrenic patients and controls. Our sample of 106 unrelated schizophrenic cases and 119 controls showed no significant differences in allele or genotype distribution between patients and controls. In particular, we were unable to support the previous observation of an excess of 4-repeat homozygotes in patients. 16 refs., 2 tabs.

  4. Modeling repeated measurement data for occupational exposure assessment and epidemiology

    NARCIS (Netherlands)

    Peretz, Chava

    2004-01-01

    Repeated measurements designs, occur frequently in the assessment of exposure to toxic chemicals. This thesis deals with the possibilities of using mixed effects models for occupational exposure assessment and in the analysis of exposure response relationships. The model enables simultaneous estima

  5. Applying the General Linear Model to Repeated Measures Problems.

    Science.gov (United States)

    Pohlmann, John T.; McShane, Michael G.

    The purpose of this paper is to demonstrate the use of the general linear model (GLM) in problems with repeated measures on a dependent variable. Such problems include pretest-posttest designs, multitrial designs, and groups by trials designs. For each of these designs, a GLM analysis is demonstrated wherein full models are formed and restrictions…

  6. Positional Repeatability Measurements Of Stepper Motors At Cryogenic Temperatures

    Science.gov (United States)

    Pompea, Stephen M.; Hall, Michael S.; Bartko, Frank; Houck, James R.

    1983-08-01

    Stepper motors operating at liquid helium temperature have multiple applications in cryogenically-cooled telescopes such as the Shuttle Infrared Telescope Facility (SIRTF). These SIRTF applications include driving cryogen flow valves, operating the Multiple Instrument Chamber (MIC) beam splitter mechanism, and operating filters and grating wheel mechanisms in the scientific instruments. The positional repeatability of the beam splitter drive mechanism is especially critical since it feeds the optical beam to the scien-tific instruments. Despite these important applications, no significant data on the positional repeatability of stepper motors at cryogenic temperatures has been available. Therefore, we conducted a series of measurements to determine the positional repeatability of a modified, off-the-shelf Berger/Lahr stepper motor (model RDM 253/25, step angle 3.6°) which had demonstrated excellent performance in previous endurance testing at LHe temperature. These test results indicated that the positional repeatability of the motor was excellent at all temperatures, with somewhat better performance at cryogenic temperatures. Another important result was that the motor could be repeatedly turned off and on while still accurately retaining its rotor position.

  7. Repeatability of OCT lens thickness measures with age and accommodation.

    Science.gov (United States)

    Doyle, Lesley; Little, Julie-Anne; Saunders, Kathryn J

    2013-12-01

    To investigate crystalline lens thickness (LT) across a range of ages and accommodative demands and to evaluate the repeatability of LT measurements using the Visante Anterior Segment Optical Coherence Tomographer (AS-OCT) (Zeiss Meditec, Germany) under non-cycloplegic conditions. Participants were 98 visually normal adults aged 18-75 years, stratified into age groups of 18-29, 30-39, 40-49, 50-59, and 60-75 years of age. Images of the crystalline lens were taken using the Visante AS-OCT during stimulation of accommodation at demands of 0, 1, 2, 3, 4, 5, and 8 D with accommodative response measured in a subgroup of participants. Images were analyzed and LT measured assuming a refractive index of 1.42. Repeat measures were taken from 86 participants for each accommodative demand at a second visit. The mean unaccommodated LT for all participants was 4.07 ± 0.40 mm. An average increase in LT of 20 μm per year was calculated (linear regression, R² = 0.61, F(1,89) = 143.92, p report the repeatability of LT measures using the Visante AS-OCT in the non-cyclopleged eye. It has also demonstrated the ability of the Visante AS-OCT to detect small changes in lens thickness with accommodation.

  8. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  9. Capturing learning effects on eye movements in repeated measures experiments

    DEFF Research Database (Denmark)

    Bagger, Martin; Orquin, Jacob Lund; Fiedler, Susann

    We propose and illustrate that repeated exposure to stimuli sets increases the size of the saccade amplitudes. Saccadic amplitudes are closely related to the perceptual span and therefore used as a measure for the information intake in an experiment. Studies on expertise have shown that experts...... experiment in which 68 participants made choices between four alternatives with three different between subject conditions varying in presentation format (verbal matrix, a pictorial matrix, and a realistic product representation). The results consistently demonstrate an increase of the saccade amplitude over...... the course of the experiment independent of condition. We conclude by discussing our results in the light of the possible increase of the perceptual span and its implications for the research procedure in eye-tracking experiments with a repeated measurement design....

  10. Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes

    Directory of Open Access Journals (Sweden)

    Carmen Lopez de la Fuente

    2014-01-01

    Full Text Available Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA in anterior segment examination. Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC, and coefficient of variation (COV. Results. Correlation among repeated measurements showed almost perfect reliability (ICC > 0.81 for all parameters except thinnest central corneal thickness (CCT (0.78, corneal thickness average out (0.79, and posterior axial curvature average out (0.60. Repeatability was excellent (COV < 10% for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean. Conclusions. GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.

  11. Novel Luminex Assay for Telomere Repeat Mass Does Not Show Well Position Effects Like qPCR.

    Directory of Open Access Journals (Sweden)

    Muhammad G Kibriya

    Full Text Available Telomere length is a potential biomarker of aging and risk for age-related diseases. For measurement of relative telomere repeat mass (TRM, qPCR is typically used primarily due to its low cost and low DNA input. But the position of the sample on a plate often impacts the qPCR-based TRM measurement. Recently we developed a novel, probe-based Luminex assay for TRM that requires ~50ng DNA and involves no DNA amplification. Here we report, for the first time, a comparison among TRM measurements obtained from (a two singleplex qPCR assays (using two different primer sets, (b a multiplex qPCR assay, and (c our novel Luminex assay. Our comparison is focused on characterizing the effects of sample positioning on TRM measurement. For qPCR, DNA samples from two individuals (K and F were placed in 48 wells of a 96-well plate. For each singleplex qPCR assay, we used two plates (one for Telomere and one for Reference gene. For the multiplex qPCR and the Luminex assay, the telomere and the reference genes were assayed from the same well. The coefficient of variation (CV of the TRM for Luminex (7.2 to 8.4% was consistently lower than singleplex qPCR (11.4 to 14.9% and multiplex qPCR (19.7 to 24.3%. In all three qPCR assays the DNA samples in the left- and right-most columns showed significantly lower TRM than the samples towards the center, which was not the case for the Luminex assay (p = 0.83. For singleplex qPCR, 30.5% of the variation in TL was explained by column-to-column variation and 0.82 to 27.9% was explained by sample-to-sample variation. In contrast, only 5.8% of the variation in TRM for the Luminex assay was explained by column-to column variation and 50.4% was explained by sample-to-sample variation. Our novel Luminex assay for TRM had good precision and did not show the well position effects of the sample that were seen in all three of the qPCR assays that were tested.

  12. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  13. Quasar Variability Measurements With SDSS Repeated Imaging and POSS Data

    CERN Document Server

    Ivezic, Z; Juric, M; Anderson, S; Hall, P B; Richards, G T; Rockosi, C M; Vanden Berk, Daniel E; Turner, E L; Knapp, G R; Gunn, J E; Schlegel, D J; Strauss, M A; Schneider, D P

    2004-01-01

    We analyze the properties of quasar variability using repeated SDSS imaging data in five UV-to-far red photometric bands, accurate to 0.02 mag, for 13,000 spectroscopically confirmed quasars. The observed time lags span the range from 3 hours to over 3 years, and constrain the quasar variability for rest-frame time lags of up to two years, and at rest-frame wavelengths from 1000 Ang. to 6000 Ang. We demonstrate that 66,000 SDSS measurements of magnitude differences can be described within the measurement noise by a simple function of only three free parameters. The addition of POSS data constrains the long-term behavior of quasar variability and provides evidence for a turn-over in the structure function. This turn-over indicates that the characteristic time scale for optical variability of quasars is of the order 1 year.

  14. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Science.gov (United States)

    Yang, Yuan-Pei; Zhang, Bing

    2017-09-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  15. Coseismic and postseismic velocity changes measured by repeating earthquakes

    Science.gov (United States)

    Schaff, David P.; Beroza, Gregory C.

    2004-10-01

    Repeating earthquakes that rupture approximately the same fault patch and have nearly identical waveforms are a useful tool for measuring temporal changes in wave propagation in the Earth's crust. Since source and path effects are common to all earthquakes in a repeating earthquake sequence (multiplet), differences in their waveforms can be attributed to changes in the characteristics of the medium. We have identified over 20 multiplets containing between 5 and 40 repeating events in the aftershock zones of the 1989 Loma Prieta and 1984 Morgan Hill, California, earthquakes. Postmain shock events reveal delays of phases in the early S wave coda of as much as 0.2 s relative to premain shock events. The delay amounts to a path-averaged coseismic velocity decrease of about 1.5% for P waves and 3.5% for S waves. Since most of the multiplets are aftershocks and follow Omori's law, we have excellent temporal sampling in the immediate postmain shock period. We find that the amplitude of the velocity decrease decays logarithmically in time following the main shock. In some cases it returns to the premain shock values, while in others it does not. Similar results are obtained for the Morgan Hill main shock. Because the fractional change in S wave velocity is greater than the fractional change in P wave velocity, it suggests that the opening or connection of fluid-filled fractures is the underlying cause. The magnitude of the velocity change implies that low effective pressures are present in the source region of the velocity change. Our results suggest that the changes are predominantly near the stations and shallow, but we cannot exclude the possibility that changes occur at greater depth as well. If the variations are shallow, we may be detecting the lingering effects of nonlinearity during main shock strong ground motion. If the variations are deep, it suggests that pore pressures at seismogenic depths are high, which would likely play a key role in the earthquake process.

  16. A Novel Signal Processing Measure to Identify Exact and Inexact Tandem Repeat Patterns in DNA Sequences

    Directory of Open Access Journals (Sweden)

    Ravi Gupta

    2007-03-01

    Full Text Available The identification and analysis of repetitive patterns are active areas of biological and computational research. Tandem repeats in telomeres play a role in cancer and hypervariable trinucleotide tandem repeats are linked to over a dozen major neurodegenerative genetic disorders. In this paper, we present an algorithm to identify the exact and inexact repeat patterns in DNA sequences based on orthogonal exactly periodic subspace decomposition technique. Using the new measure our algorithm resolves the problems like whether the repeat pattern is of period P or its multiple (i.e., 2P, 3P, etc., and several other problems that were present in previous signal-processing-based algorithms. We present an efficient algorithm of O(NLw logLw, where N is the length of DNA sequence and Lw is the window length, for identifying repeats. The algorithm operates in two stages. In the first stage, each nucleotide is analyzed separately for periodicity, and in the second stage, the periodic information of each nucleotide is combined together to identify the tandem repeats. Datasets having exact and inexact repeats were taken up for the experimental purpose. The experimental result shows the effectiveness of the approach.

  17. Bayesian Concordance Correlation Coefficient with Application to Repeatedly Measured Data

    Directory of Open Access Journals (Sweden)

    Atanu BHATTACHARJEE

    2015-10-01

    Full Text Available Objective: In medical research, Lin's classical concordance correlation coefficient (CCC is frequently applied to evaluate the similarity of the measurements produced by different raters or methods on the same subjects. It is particularly useful for continuous data. The objective of this paper is to propose the Bayesian counterpart to compute CCC for continuous data. Material and Methods: A total of 33 patients of astrocytoma brain treated in the Department of Radiation Oncology at Malabar Cancer Centre is enrolled in this work. It is a continuous data of tumor volume and tumor size repeatedly measured during baseline pretreatment workup and post surgery follow-ups for all patients. The tumor volume and tumor size are measured separately by MRI and CT scan. The agreement of measurement between MRI and CT scan is calculated through CCC. The statistical inference is performed through Markov Chain Monte Carlo (MCMC technique. Results: Bayesian CCC is found suitable to get prominent evidence for test statistics to explore the relation between concordance measurements. The posterior mean estimates and 95% credible interval of CCC on tumor size and tumor volume are observed with 0.96(0.87,0.99 and 0.98(0.95,0.99 respectively. Conclusion: The Bayesian inference is adopted for development of the computational algorithm. The approach illustrated in this work provides the researchers an opportunity to find out the most appropriate model for specific data and apply CCC to fulfill the desired hypothesis.

  18. A Simple and Transparent Alternative to Repeated Measures ANOVA

    Directory of Open Access Journals (Sweden)

    James W. Grice

    2015-09-01

    Full Text Available Observation Oriented Modeling is a novel approach toward conceptualizing and analyzing data. Compared with traditional parametric statistics, Observation Oriented Modeling is more intuitive, relatively free of assumptions, and encourages researchers to stay close to their data. Rather than estimating abstract population parameters, the overarching goal of the analysis is to identify and explain distinct patterns within the observations. Selected data from a recent study by Craig et al. were analyzed using Observation Oriented Modeling; this analysis was contrasted with a traditional repeated measures ANOVA assessment. Various pitfalls in traditional parametric analyses were avoided when using Observation Oriented Modeling, including the presence of outliers and missing data. The differences between Observation Oriented Modeling and various parametric and nonparametric statistical methods were finally discussed.

  19. Matrix-based concordance correlation coefficient for repeated measures.

    Science.gov (United States)

    Hiriote, Sasiprapa; Chinchilli, Vernon M

    2011-09-01

    In many clinical studies, Lin's concordance correlation coefficient (CCC) is a common tool to assess the agreement of a continuous response measured by two raters or methods. However, the need for measures of agreement may arise for more complex situations, such as when the responses are measured on more than one occasion by each rater or method. In this work, we propose a new CCC in the presence of repeated measurements, called the matrix-based concordance correlation coefficient (MCCC) based on a matrix norm that possesses the properties needed to characterize the level of agreement between two p× 1 vectors of random variables. It can be shown that the MCCC reduces to Lin's CCC when p= 1. For inference, we propose an estimator for the MCCC based on U-statistics. Furthermore, we derive the asymptotic distribution of the estimator of the MCCC, which is proven to be normal. The simulation studies confirm that overall in terms of accuracy, precision, and coverage probability, the estimator of the MCCC works very well in general cases especially when n is greater than 40. Finally, we use real data from an Asthma Clinical Research Network (ACRN) study and the Penn State Young Women's Health Study for demonstration.

  20. Repeatability of the modified Thorington card used to measure far heterophoria.

    Science.gov (United States)

    Cebrian, Jose Luis; Antona, Beatriz; Barrio, Ana; Gonzalez, Enrique; Gutierrez, Angel; Sanchez, Isabel

    2014-07-01

    To determine the interexaminer and intraexaminer repeatability of the modified Thorington test (TH) for distance vision in young adults and to compare these results with those observed for the heterophoria tests most commonly used in clinical practice. Agreement among tests was also assessed. Distance heterophoria was quantified on two separate occasions by two examiners in 110 subjects aged 18 to 32 years (mean, 19.74 years; SD, 2.5 years) using four different tests: cover test (CT) Von Graefe, Maddox rod, and modified TH. The repeatability of the tests and agreement between them was estimated by the Bland and Altman method whereby the mean difference and the 95% limits of agreement were determined as the coefficient of repeatability (COR) and coefficient of agreement. The Thorington test showed best interexaminer repeatability (COR = ±1.43Δ), followed closely by CT (COR = ±1.65Δ), whereas best intraexaminer repeatability was observed for CT (COR = ±1.28Δ) followed by TH (COR = ±1.51Δ). Among the different combinations of tests, TH and CT showed best agreement indicated by the lowest coefficient of agreement (±2.23Δ) and a low mean difference (-0.63Δ) between measurements. Good interexaminer and intraexaminer repeatability was observed for both TH and CT, and agreement between the two tests was also good. Given the simple administration of the TH, we recommend its clinical use to quantify distance horizontal heterophoria.

  1. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.

    Science.gov (United States)

    Wilson, Derek C; Niosi, Christina A; Zhu, Qingan A; Oxland, Thomas R; Wilson, David R

    2006-01-01

    We assessed the repeatability and accuracy of a relatively new, resistance-based sensor (Tekscan 6900) for measuring lumbar spine facet loads, pressures, and contact areas in cadaver specimens. Repeatability of measurements in the natural facet joint was determined for five trials of four specimens loaded in pure moment (+/- 7.5 N m) flexibility tests in axial rotation and flexion-extension. Accuracy of load measurements in four joints was assessed by applying known compressive loads of 25, 50, and 100 N to the natural facet joint in a materials testing machine and comparing the known applied load to the measured load. Measurements of load were obtained using two different calibration approaches: linear and two-point calibrations. Repeatability for force, pressure, and area (average of standard deviation as a percentage of the mean for all trials over all specimens) was 4-6% for axial rotation and 7-10% for extension. Peak resultant force in axial rotation was 30% smaller when calculated using the linear calibration method. The Tekscan sensor overestimated the applied force by 18 +/- 9% (mean+/-standard deviation), 35 +/- 7% and 50 +/- 9% for compressive loads of 100, 50, and 25 N, respectively. The two-point method overestimated the loads by 35 +/- 16%, 45 +/- 7%, and 56 +/- 10% for the same three loads. Our results show that the Tekscan sensor is repeatable. However, the sensor measurement range is not optimal for the small loads transmitted by the facets and measurement accuracy is highly dependent on calibration protocol.

  2. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  3. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Directory of Open Access Journals (Sweden)

    Beatriz Antona

    2015-04-01

    Full Text Available AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus. METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision. RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability (COR: ±13 and ±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted. In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby (COR: ±69s arc and Randot (COR: ±72s arc. In both groups, the TNO test showed poorest agreement with the other tests. CONCLUSION: The repeatability of stereoacuity measures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  4. Do monkey F5 mirror neurons show changes in firing rate during repeated observation of natural actions?

    Science.gov (United States)

    Kilner, J M; Kraskov, A; Lemon, R N

    2014-03-01

    Mirror neurons were first discovered in area F5 of macaque monkeys. In humans, noninvasive studies have demonstrated an increased blood oxygen level-dependent (BOLD) signal in homologous motor areas during action observation. One approach to demonstrating that this indicates the existence of mirror neurons in humans has been to employ functional (f)MRI adaptation to test whether the same population of neurons is active during both observation and execution conditions. Although a number of human studies have reported fMRI adaptation in these areas, a recent study has shown that macaque mirror neurons do not attenuate their firing rate with two repetitions. Here we investigated whether mirror neurons modulate their firing rate when monkeys observed the same repeated natural action multiple times. We recorded from 67 mirror neurons in area F5 of two macaque monkeys while they observed an experimenter perform a reach-to-grasp action on a small food reward using a precision grip. Although no changes were detectable for the first two repetitions, we show that both the firing rate and the latency at which mirror neurons discharged during observation were subtly modulated by the repetition of the observed action over 7-10 trials. Significant adaption was mostly found in the period immediately before the grasp was performed. We also found that the local field potential activity in F5 (beta-frequency range, 16-23 Hz), which is attenuated during action observation, also showed systematic changes with repeated observation. These LFP changes occurred well in advance of the mirror neuron adaptation. We conclude that macaque mirror neurons can show intra-modal adaptation, but whether this is related to fMRI adaptation of the BOLD signal requires further investigation.

  5. Rank-Based Analysis of Unbalanced Repeated Measures Data

    Directory of Open Access Journals (Sweden)

    M. Mushfiqur Rashid

    2012-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} In this article, we have developed a rank (intra-subject based analysis of clinical trials with unbalanced repeated measures data. We assume that the errors within each patient are exchangeable and continuous random variables. This rank-based inference is valid when the unbalanced data are missing either completely at random or by design. A drop in dispersion test is developed for general linear hypotheses. A numerical example is given to illustrate the procedure.

  6. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  7. The SIDER2 elements, interspersed repeated sequences that populate the Leishmania genomes, constitute subfamilies showing chromosomal proximity relationship

    Directory of Open Access Journals (Sweden)

    Thomas M Carmen

    2008-06-01

    Full Text Available Abstract Background Protozoan parasites of the genus Leishmania are causative agents of a diverse spectrum of human diseases collectively known as leishmaniasis. These eukaryotic pathogens that diverged early from the main eukaryotic lineage possess a number of unusual genomic, molecular and biochemical features. The completion of the genome projects for three Leishmania species has generated invaluable information enabling a direct analysis of genome structure and organization. Results By using DNA macroarrays, made with Leishmania infantum genomic clones and hybridized with total DNA from the parasite, we identified a clone containing a repeated sequence. An analysis of the recently completed genome sequence of L. infantum, using this repeated sequence as bait, led to the identification of a new class of repeated elements that are interspersed along the different L. infantum chromosomes. These elements turned out to be homologues of SIDER2 sequences, which were recently identified in the Leishmania major genome; thus, we adopted this nomenclature for the Leishmania elements described herein. Since SIDER2 elements are very heterogeneous in sequence, their precise identification is rather laborious. We have characterized 54 LiSIDER2 elements in chromosome 32 and 27 ones in chromosome 20. The mean size for these elements is 550 bp and their sequence is G+C rich (mean value of 66.5%. On the basis of sequence similarity, these elements can be grouped in subfamilies that show a remarkable relationship of proximity, i.e. SIDER2s of a given subfamily locate close in a chromosomal region without intercalating elements. For comparative purposes, we have identified the SIDER2 elements existing in L. major and Leishmania braziliensis chromosomes 32. While SIDER2 elements are highly conserved both in number and location between L. infantum and L. major, no such conservation exists when comparing with SIDER2s in L. braziliensis chromosome 32. Conclusion

  8. Repeatability and reproducibility of horizontal corneal diameter and anterior corneal power measurements using the Oculus Keratograph 4

    Directory of Open Access Journals (Sweden)

    Khathutshelo P. Mashige

    2016-03-01

    Full Text Available Purpose: To evaluate the repeatability and reproducibility of horizontal corneal diameter (HCD and anterior corneal power (ACP measurements obtained with the Oculus Keratograph 4 (OCULUS Optikgeräte GmbH.Methods: These parameters (HCD and ACP were prospectively measured in quick succession three times in each of the right eyes of 40 healthy subjects, aged 18–28 years, with normal vision (6/6 or better visual acuity in the first session by a single examiner. Measurements were then repeated in the second session scheduled 1 week later by the same examiner using the same instrument. Repeatability and reproducibility of HCD and ACP measurements was assessed based on the intra-session and intersession within-subject standard deviation (sw, repeatability (2.77sw, coefficient of variation (CoV and intra-class correlation coefficient (ICC.Results: Intra-session repeatability and intersession reproducibility of all measured parameters showed a repeatability (2.77sw of 0.35 mm or less for HCD and 0.35 D or less for ACP, a CoV of 0.30% or less and an ICC of more than 0.9.Conclusion: HCD and ACP measurements obtained using an Oculus Keratograph 4 show good repeatability and reproducibility in healthy eyes; therefore, these parameters can be used for longitudinal follow-up when measured with this device.

  9. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development...

  10. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  11. Detecting tropical forest biomass dynamics from repeated airborne lidar measurements

    Directory of Open Access Journals (Sweden)

    V. Meyer

    2013-08-01

    census data, differences of approximately one year between the ground census and lidar measurements, and differences in sensor characteristics. Our results indicate that the 50 ha BCI plot lost a significant amount of biomass (−0.8 Mg ha−1 yr−1 ± 2.2(SD over the past decade (2000–2010. Over the entire island and during the same period, mean AGB change was 0.2 ± 2.4 Mg ha−1 yr−1 with old growth forests losing −0.7 Mg ha−1 yr−1 ± 2.2 (SD, and secondary forests gaining +1.8 Mg ha yr−1 ± 3.4 (SD biomass. Our analysis suggests that repeated lidar surveys, despite taking measurement with different sensors, can estimate biomass changes in old-growth tropical forests at landscape scales (>10 ha.

  12. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Institute of Scientific and Technical Information of China (English)

    Beatriz; Antona; Ana; Barrio; Isabel; Sanchez; Enrique; Gonzalez; Guadalupe; Gonzalez

    2015-01-01

    AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24 h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability(COR): ±13 and±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted.In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby(COR: ±69s arc)and Randot(COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.CONCLUSION:Therepeatabilityofstereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  13. Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography

    Science.gov (United States)

    Chen, Chieh-Li; Bojikian, Karine D.; Xin, Chen; Wen, Joanne C.; Gupta, Divakar; Zhang, Qinqin; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.; Wang, Ruikang K.

    2016-06-01

    Optical coherence tomography angiography (OCTA) has increasingly become a clinically useful technique in ophthalmic imaging. We evaluate the repeatability and reproducibility of blood perfusion in the optic nerve head (ONH) measured using optical microangiography (OMAG)-based OCTA. Ten eyes from 10 healthy volunteers are recruited and scanned three times with a 68-kHz Cirrus HD-OCT 5000-based OMAG prototype system (Carl Zeiss Meditec Inc., Dublin, California) centered at the ONH involving two separate visits within six weeks. Vascular images are generated with OMAG processing by detecting the differences in OCT signals between consecutive B-scans acquired at the same retina location. ONH perfusion is quantified as flux, vessel area density, and normalized flux within the ONH for the prelaminar, lamina cribrosa, and the full ONH. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) are used to evaluate intravisit and intervisit repeatability, and interobserver reproducibility. ONH perfusion measurements show high repeatability [CV≤3.7% (intravisit) and ≤5.2% (intervisit)] and interobserver reproducibility (ICC≤0.966) in all three layers by three metrics. OCTA provides a noninvasive method to visualize and quantify ONH perfusion in human eyes with excellent repeatability and reproducibility, which may add additional insight into ONH perfusion in clinical practice.

  14. Measuring Political Polarization: Twitter shows the two sides of Venezuela

    CERN Document Server

    Morales, A J; Losada, J C; Benito, R M

    2015-01-01

    We say that a population is perfectly polarized when divided in two groups of the same size and opposite opinions. In this paper, we propose a methodology to study and measure the emergence of polarization from social interactions. We begin by proposing a model to estimate opinions in which a minority of influential individuals propagate their opinions through a social network. The result of the model is an opinion probability density function. Next, we propose an index to quantify the extent to which the resulting distribution is polarized. Finally, we apply the proposed methodology to a Twitter conversation about the late Venezuelan president, Hugo Ch\\'avez, finding a good agreement between our results and offline data. Hence, we show that our methodology can detect different degrees of polarization, depending on the structure of the network.

  15. Measuring political polarization: Twitter shows the two sides of Venezuela

    Science.gov (United States)

    Morales, A. J.; Borondo, J.; Losada, J. C.; Benito, R. M.

    2015-03-01

    We say that a population is perfectly polarized when divided in two groups of the same size and opposite opinions. In this paper, we propose a methodology to study and measure the emergence of polarization from social interactions. We begin by proposing a model to estimate opinions in which a minority of influential individuals propagate their opinions through a social network. The result of the model is an opinion probability density function. Next, we propose an index to quantify the extent to which the resulting distribution is polarized. Finally, we apply the proposed methodology to a Twitter conversation about the late Venezuelan president, Hugo Chávez, finding a good agreement between our results and offline data. Hence, we show that our methodology can detect different degrees of polarization, depending on the structure of the network.

  16. Methane Seeps in the Gulf of Mexico: repeat acoustic surveying shows highly temporally and spatially variable venting

    Science.gov (United States)

    Beaumont, B. C.; Raineault, N.

    2016-02-01

    Scientists have recognized that natural seeps account for a large amount of methane emissions. Despite their widespread occurrence in areas like the Gulf of Mexico, little is known about the temporal variability and site-scale spatial variability of venting over time. We used repeat acoustic surveys to compare multiple days of seep activity and determine the changes in the locus of methane emission and plume height. The Sleeping Dragon site was surveyed with an EM302 multibeam sonar on three consecutive days in 2014 and 4 days within one week in 2015. The data revealed three distinctive plume regions. The locus of venting varied by 10-60 meters at each site. The plume that exhibited the least spatial variability in venting, was also the most temporally variable. This seep was present in one-third of survey dates in 2014 and three quarters of survey dates in 2015, showing high day-to-day variability. The plume height was very consistent for this plume, whereas the other plumes were more consistent temporally, but varied in maximum plume height detection by 25-85 m. The single locus of emission at the site that had high day-to-day variability may be due to a single conduit for methane release, which is sometimes closed off by carbonate or clathrate hydrate formation. In addition to day-to-day temporal variability, the locus of emission at one site was observed to shift from a point-source in 2014 to a diffuse source in 2015 at a nearby location. ROV observations showed that one of the seep sites that closed off temporarily, experienced an explosive breakthrough of gas, releasing confined methane and blowing out rock. The mechanism that causes on/off behavior of certain plumes, combined with the spatial variability of the locus of methane release shown in this study may point to carbonate or hydrate formation in the seep plumbing system and should be further investigated.

  17. Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Hoffman, Jim; Miller, Tim; Lou, Yunling; Muellerschoen, Ron; Zebker, Howard; Madsen, Soren; Rosen, Paul

    2004-01-01

    Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

  18. Iterative Weighted Semiparametric Least Squares Estimation in Repeated Measurement Partially Linear Regression Models

    Institute of Scientific and Technical Information of China (English)

    Ge-mai Chen; Jin-hong You

    2005-01-01

    Consider a repeated measurement partially linear regression model with an unknown vector pasemiparametric generalized least squares estimator (SGLSE) ofβ, we propose an iterative weighted semiparametric least squares estimator (IWSLSE) and show that it improves upon the SGLSE in terms of asymptotic covariance matrix. An adaptive procedure is given to determine the number of iterations. We also show that when the number of replicates is less than or equal to two, the IWSLSE can not improve upon the SGLSE.These results are generalizations of those in [2] to the case of semiparametric regressions.

  19. Using repeated measures of sleep disturbances to predict future diagnosis-specific work disability

    DEFF Research Database (Denmark)

    Salo, Paula; Vahtera, Jussi; Hall, Martica

    2012-01-01

    It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability.......It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability....

  20. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  1. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  2. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Science.gov (United States)

    Kroner, E.; Maboudian, R.; Arzt, E.

    2009-09-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  3. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Energy Technology Data Exchange (ETDEWEB)

    Kroner, E; Arzt, E [INM-Leibniz Institute for New Materials, Campus D2 2, 66125 Saarbruecken (Germany); Maboudian, R, E-mail: elmar.kroner@inm-gmbh.de [Department of Chem. Eng., 201 Gilman Hall, University of California, Berkeley, CA 94720-1462 (United States)

    2009-09-15

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  4. Assessment of bone loss with repeated bone mineral measurements: Application to measurements on the individual patient

    Energy Technology Data Exchange (ETDEWEB)

    Wahner, H.W.

    1987-02-01

    Longitudinal measurements on lumbar spine and mid-radius were made by bone absorptiometry techniques in 139 normal women. Bone mineral was measured every 6 months over an median interval of 2.1 years. The results revealed that bone loss at different skeletal sites is non-uniform with equal bone loss patterns in all patients and relatively small variations in bone loss rate between normal women. For achieving these results there is strong demand on high precision and properly spaced measuring intervals for long-term rate of loss measurements. For exclusion of progressive degenerative disease a radiographic evaluation of the spine in the beginning and at the end of the study is mandatory as compression fractures or trauma reveal bone mineral changes independent from the agerelated bone loss. These repeated bone mineral measurements are useful for monitoring and follow-up studies during different therapeutic regimens.

  5. Measurement of bedform migration rates on the Lower Missouri River in Missouri, USA using repeat measurements with a multibeam echosounder

    Science.gov (United States)

    Elliott, Caroline M.; Jacobson, Robert B.

    2016-01-01

    High-resolution repeat multibeam echosounder measurements on the Lower Missouri River near Boonville, Missouri, USA show bedform movement and sand storage patterns over daily to seasonal time scales and a range of discharges. Higher flows are frequently, but not always, associated with larger bedforms, higher bedform movement rates, and higher bedload transport rates. Measurements of the temporal and spatial variability in sand dune sizes, transport rates, and sand storage across the river channel have increased understanding of the dynamics of habitats utilized by benthic organisms over multiple life stages and daily to seasonal time scales.

  6. The repeat domain of the type III effector protein PthA shows a TPR-like structure and undergoes conformational changes upon DNA interaction.

    Science.gov (United States)

    Murakami, Mário Tyago; Sforça, Mauricio Luis; Neves, Jorge Luiz; Paiva, Joice Helena; Domingues, Mariane Noronha; Pereira, André Luiz Araujo; Zeri, Ana Carolina de Mattos; Benedetti, Celso Eduardo

    2010-12-01

    Many plant pathogenic bacteria rely on effector proteins to suppress defense and manipulate host cell mechanisms to cause disease. The effector protein PthA modulates the host transcriptome to promote citrus canker. PthA possesses unusual protein architecture with an internal region encompassing variable numbers of near-identical tandem repeats of 34 amino acids termed the repeat domain. This domain mediates protein-protein and protein-DNA interactions, and two polymorphic residues in each repeat unit determine DNA specificity. To gain insights into how the repeat domain promotes protein-protein and protein-DNA contacts, we have solved the structure of a peptide corresponding to 1.5 units of the PthA repeat domain by nuclear magnetic resonance (NMR) and carried out small-angle X-ray scattering (SAXS) and spectroscopic studies on the entire 15.5-repeat domain of PthA2 (RD2). Consistent with secondary structure predictions and circular dichroism data, the NMR structure of the 1.5-repeat peptide reveals three α-helices connected by two turns that fold into a tetratricopeptide repeat (TPR)-like domain. The NMR structure corroborates the theoretical TPR superhelix predicted for RD2, which is also in agreement with the elongated shape of RD2 determined by SAXS. Furthermore, RD2 undergoes conformational changes in a pH-dependent manner and upon DNA interaction, and shows sequence similarities to pentatricopeptide repeat (PPR), a nucleic acid-binding motif structurally related to TPR. The results point to a model in which the RD2 structure changes its compactness as it embraces the DNA with the polymorphic diresidues facing the interior of the superhelix oriented toward the nucleotide bases.

  7. Plasmodium falciparum field isolates from areas of repeated emergence of drug resistant malaria show no evidence of hypermutator phenotype.

    Science.gov (United States)

    Brown, Tyler S; Jacob, Christopher G; Silva, Joana C; Takala-Harrison, Shannon; Djimdé, Abdoulaye; Dondorp, Arjen M; Fukuda, Mark; Noedl, Harald; Nyunt, Myaing Myaing; Kyaw, Myat Phone; Mayxay, Mayfong; Hien, Tran Tinh; Plowe, Christopher V; Cummings, Michael P

    2015-03-01

    Multiple transcontinental waves of drug resistance in Plasmodium falciparum have originated in Southeast Asia before spreading westward, first into the rest of Asia and then to sub-Saharan Africa. In vitro studies have suggested that hypermutator P. falciparum parasites may exist in Southeast Asia and that an increased rate of acquisition of new mutations in these parasites may explain the repeated emergence of drug resistance in Southeast Asia. This study is the first to test the hypermutator hypothesis using field isolates. Using genome-wide SNP data from human P. falciparum infections in Southeast Asia and West Africa and a test for relative rate differences we found no evidence of increased relative substitution rates in P. falciparum isolates from Southeast Asia. Instead, we found significantly increased substitution rates in Mali and Bangladesh populations relative to those in populations from Southeast Asia. Additionally we found no association between increased relative substitution rates and parasite clearance following treatment with artemisinin derivatives.

  8. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability

    Directory of Open Access Journals (Sweden)

    Sousa Filipe

    2015-12-01

    Full Text Available Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p < 0.05. Pearson product-moment correlation measured the relationship between mechanical variables and free running performance. A total impulse, the rate of force development and maximum force did not show significant differences for most sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35. Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p < 0.001, followed by mean force (r = -0.61; p < 0.001 and total work (r = -0.50; p < 0.001. It was concluded that under a severe work-to-rest ratio condition, power variables were better suited to evaluating repeated sprint ability than the other studied variables.

  9. [A case of bronchial foreign body due to citrus fruit seed aspiration showing multiple pulmonary infiltration repeatedly].

    Science.gov (United States)

    Morimatsu, Yoshitaka; Aoki, Yuka; Mizoguchi, Yusuke; Kitasato, Hirohiko; Aizawa, Hisamichi

    2005-12-01

    We report a case of a bronchial foreign body in a 76-year-old citrus fruit farmer. The patient was detected patchy infiltration (ground-glass attenuation) of the right upper lung field on the chest X-ray on Dec. 26th, 2003. The shadow tended to disappear after treatment with antibiotics. The same shadow was detected again 10 months later and the patient underwent a bronchoscopic examination. A foreign body was found lodged in the center of the right upper bronchus, associated with bronchial stenosis due to mucosal edema. The abnormal shadow disappeared after the foreign body, which we decided was a citrus fruit seed, was removed. From the time course of the present illness and a retrospective evaluation of previous chest X-rays, the patient had aspirated the foreign body 18 months prior to his admission for bronchoscopy. We should be careful of the possibility of foreign bodies even when the elderly do not present a history of foreign body aspiration. It is important to consider the possibility of a bronchial foreign body in patients with repeated pneumonia, and to perform bronchoscopy aggressively.

  10. Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.

    Science.gov (United States)

    Cruz, Antonio M; Maninchedda, Ugo E; Burger, Dominik; Wanda, Sabine; Vidondo, Beatriz

    2017-09-01

    OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.

  11. Analysis of repeated measurements from medical research when observations are missing

    OpenAIRE

    Walker, K.

    2007-01-01

    Subject dropout is a common problem in repeated measurements health stud ies. Where dropout is related to the response, the results obtained can be substantially biased. The research in this thesis is motivated by a repeated measurements asthma clinical trial with substantial patient dropout. In practice the extent to which missing observations affect parameter esti mates and their efficiency is not clear. Through extensive simulation studies under various scenarios and missing data mechanism...

  12. Precision (Repeatability and Reproducibility and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

    Directory of Open Access Journals (Sweden)

    Yanjun Hua

    Full Text Available To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks, flat keratometry (Kf, mean keratometry (Km, J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw, coefficient of variation (CoV, test-retest repeatability (2.77Sw, and intraclass correlation coefficient (ICC. Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA.Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446. Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05. The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements.The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not

  13. Separating climate-induced mass transfers and instrumental effects from tectonic signal in repeated absolute gravity measurements

    Science.gov (United States)

    Van Camp, M.; Viron, O.; Avouac, J. P.

    2016-05-01

    We estimate the signature of the climate-induced mass transfers in repeated absolute gravity measurements based on satellite gravimetric measurements from the Gravity Recovery and Climate Experiment (GRACE) mission. We show results at the globe scale and compare them with repeated absolute gravity (AG) time behavior in three zones where AG surveys have been published: Northwestern Europe, Canada, and Tibet. For 10 yearly campaigns, the uncertainties affecting the determination of a linear gravity rate of change range 3-4 nm/s2/a in most cases, in the absence of instrumental artifacts. The results are consistent with what is observed for long-term repeated campaigns. We also discuss the possible artifact that can result from using short AG survey to determine the tectonic effects in a zone of high hydrological variability. We call into question the tectonic interpretation of several gravity changes reported from stations in Tibet, in particular the variation observed prior to the 2015 Gorkha earthquake.

  14. Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

    Science.gov (United States)

    Fukuda, Shinichi; Kawana, Keisuke; Yasuno, Yoshiaki; Oshika, Tetsuro

    2011-03-01

    To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. Nonrandomized clinical trial. Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. The concordance correlation coefficient for repeated measures estimated by variance components.

    Science.gov (United States)

    Carrasco, Josep L; King, Tonya S; Chinchilli, Vernon M

    2009-01-01

    The concordance correlation coefficient (CCC) is an index that is commonly used to assess the degree of agreement between observers on measuring a continuous characteristic. Here, a CCC for longitudinal repeated measurements is developed through the appropriate specification of the intraclass correlation coefficient from a variance components linear mixed model. A case example and the results of a simulation study are provided.

  16. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind li

  17. The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography

    Science.gov (United States)

    Chang, Pingjun; Li, Jin; Savini, Giacomo; Huang, Jinhai; Huang, Shenghai; Zhao, Yinying; Liao, Na; Lin, Lei; Yu, Xiaoyu; Zhao, Yun-e

    2015-01-01

    Purpose To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. Methods Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening. Results PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements. Conclusion SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex. PMID:26600254

  18. Hierarchical linear model: thinking outside the traditional repeated-measures analysis-of-variance box.

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C

    2015-04-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data.

  19. Hierarchical Linear Model: Thinking Outside the Traditional Repeated-Measures Analysis-of-Variance Box

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C.

    2015-01-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data. PMID:25875072

  20. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  1. Repeated quantitative perfusion and contrast permeability measurement in the MRI examination of a CNS tumor

    Energy Technology Data Exchange (ETDEWEB)

    Vonken, E.P.A.; Osch, M.J.P. van; Willems, P.W.A.; Zwan, A. van der; Bakker, C.J.G.; Viergever, M.A.; Mali, W.P.T.M. [University Hospital Utrecht (Netherlands)

    2000-09-01

    This study reports on the results of quantitative MRI perfusion and contrast permeability measurement on two occasions in one patient. The measurements were separated 81 days in time. The tumor grew considerably in this period, but no change was found with respect to perfusion and contrast permeability. Non-involved white matter values were reproduced to demonstrate repeatability. The presented approach to dynamic susceptibility contrast MRI allows fast and repeatable quantitative assessment of perfusion and is easily integrated in a conventional brain tumor protocol. (orig.)

  2. Australian House Prices: A Comparison of Hedonic and Repeat-sales Measures

    OpenAIRE

    James Hansen

    2006-01-01

    House prices are intrinsically difficult to measure due to changes in the composition of properties sold through time and changes in the quality of housing. I provide an overview of the theoretical nature of these issues and consider how regression-based measures of house prices – hedonic and repeat-sales measures – can control for compositional and quality change. I then explore whether these regression-based alternatives can provide accurate estimates of pure house price changes in the Aust...

  3. Concordance correlation coefficients estimated by generalized estimating equations and variance components for longitudinal repeated measurements.

    Science.gov (United States)

    Tsai, Miao-Yu

    2017-04-15

    The concordance correlation coefficient (CCC) is a commonly accepted measure of agreement between two observers for continuous responses. This paper proposes a generalized estimating equations (GEE) approach allowing dependency between repeated measurements over time to assess intra-agreement for each observer and inter- and total agreement among multiple observers simultaneously. Furthermore, the indices of intra-, inter-, and total agreement through variance components (VC) from an extended three-way linear mixed model (LMM) are also developed with consideration of the correlation structure of longitudinal repeated measurements. Simulation studies are conducted to compare the performance of the GEE and VC approaches for repeated measurements from longitudinal data. An application of optometric conformity study is used for illustration. In conclusion, the GEE approach allowing flexibility in model assumptions and correlation structures of repeated measurements gives satisfactory results with small mean square errors and nominal 95% coverage rates for large data sets, and when the assumption of the relationship between variances and covariances for the extended three-way LMM holds, the VC approach performs outstandingly well for all sample sizes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Repeatability of cardiac-MRI-measured right ventricular size and function in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Rowan; Salem, Yishay [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Shah, Amee; Lai, Wyman W. [Morgan Stanley Children' s Hospital of New York Presbyterian, New York, NY (United States); Nielsen, James C. [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Mount Sinai Children' s Heart Center, Box 1201, New York, NY (United States)

    2011-08-15

    The measurement error for right ventricular (RV) size and function assessed by cardiac MRI (CMRI) in congenital heart disease has not been fully characterized. As CMRI parameters are being increasingly utilized to make clinical decisions, defining error in the clinical setting is critical. This investigation examines the repeatability of CMRI for RV size and function. Forty consecutive people with congenital heart disease involving the RV were retrospectively identified. Contouring of RV volumes was performed by two expert CMRI clinicians. The coefficient of variability and repeatability coefficients were calculated. Repeatability coefficients were multiplied by the mean value for each group studied to define a threshold beyond which measurement error was unlikely to be responsible. The variability for indexed RV end-diastolic volume = 3.2% and 3.3% for intra- and interobserver comparisons, respectively. The repeatability coefficients were 13.2% and 14.9% for intra- and interobserver comparisons, which yielded threshold values of 15.1 ml/m{sup 2} and 20.2 ml/m{sup 2}, respectively. For RV ejection fraction (EF), the repeatability coefficients for intra- and interobserver comparisons were 5.0% and 6.0%, which resulted in threshold values of 2.6 EF% and 3.0 EF%. The threshold values generated can be used during serial assessment of RV size and function. (orig.)

  5. Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues.

    Science.gov (United States)

    Liu, Helen; Holt, Cathy; Evans, Sam

    2007-01-01

    Optical motion analysis techniques have been widely used in biomechanics for measuring large-scale motions such as gait, but have not yet been significantly explored for measuring smaller movements such as the tooth displacements under load. In principle, very accurate measurements could be possible and this could provide a valuable tool in many engineering applications. The aim of this study was to evaluate accuracy and repeatability of the Qualisys ProReflex-MCU120 system when measuring small displacements, as a step towards measuring tooth displacements to characterise the properties of the periodontal ligament. Accuracy and repeatability of the system was evaluated using a wedge comparator with a resolution of 0.25 microm to provide measured marker displacements in three orthogonal directions. The marker was moved in ten steps in each direction, for each of seven step sizes (0.5, 1, 2, 3, 5, 10, and 20 microm), repeated five times. Spherical and diamond markers were tested. The system accuracy (i.e. percentage of maximum absolute error in range/measurement range), in the 20-200 microm ranges, was +/-1.17%, +/-1.67% and +/-1.31% for the diamond marker in x, y and z directions, while the system accuracy for the spherical marker was +/-1.81%, +/-2.37% and +/-1.39%. The system repeatability (i.e. maximum standard deviation in the measurement range) measured under the different days, light intensity and temperatures for five times, carried out step up and then step down measurements for the same step size, was +/-1.7, +/-2.3 and +/-1.9 microm for the diamond marker, and +/-2.6, +/-3.9 and +/-1.9 microm for the spherical marker in x, y and z directions, respectively. These results demonstrate that the system suffices accuracy for measuring tooth displacements and could potentially be useful in many other applications.

  6. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  7. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...

  8. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    2011-01-01

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and r

  9. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  10. REPEATABILITY OF THE SUGAR ABSORPTION TEST, USING LACTULOSE AND MANNITOL, FOR MEASURING INTESTINAL PERMEABILITY FOR SUGARS

    NARCIS (Netherlands)

    VANELBURG, RM; UIL, JJ; KOKKE, FTM; MULDER, AM; VANDEBROEK, WGM; MULDER, CJJ; HEYMANS, HSA

    1995-01-01

    Differential sugar-absorption tests for measuring intestinal permeability for sugars have been studied in a variety of gastrointestinal diseases. Their use in general practice has been hampered by a lack of data on reference values and repeatability of the test and the laboratory assay. In this stud

  11. The Multilevel Approach to Repeated Measures for Complete and Incomplete Data

    NARCIS (Netherlands)

    Maas, CJM; Snijders, TAB

    2003-01-01

    Repeated measurements often are analyzed by multivariate analysis of variance (MANOVA). An alternative approach is provided by multilevel analysis, also called the hierarchical linear model (HLM), which makes use of random coefficient models. This paper is a tutorial which indicates that the HLM can

  12. Repeated measures of serum glucose and insulin in relation to postmenopausal breast cancer.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi; Caan, Bette J; Chlebowski, Rowan T; Gunter, Marc J; Ho, Gloria Y F; Rodriguez, Beatriz L; Shikany, James M; Strickler, Howard D; Vitolins, Mara Z; Rohan, Thomas E

    2009-12-01

    Experimental and epidemiological evidence suggests that circulating glucose and insulin may play a role in breast carcinogenesis. However, few cohort studies have examined breast cancer risk in association with glucose and insulin levels, and studies to date have had only baseline measurements of exposure. We conducted a longitudinal study of postmenopausal breast cancer risk using the 6% random sample of women in the Women's Health Initiative clinical trials whose fasting blood samples, provided at baseline and at years 1, 3 and 6, were analyzed for glucose and insulin. In addition, a 1% sample of women in the observational study, who had glucose and insulin measured in fasting blood samples drawn at baseline and in year 3, were included in the analysis. We used Cox proportional hazards models to estimate hazard ratios and 95% confidence intervals for the association of baseline and follow-up measurements of serum glucose and insulin with breast cancer risk. All statistical tests were 2-sided. Among 5,450 women with baseline serum glucose and insulin values, 190 incident cases of breast cancer were ascertained over a median of 8.0 years of follow-up. The highest tertile of baseline insulin, relative to the lowest, was associated with a 2-fold increase in risk in the total population (multivariable hazard ratio 2.22, 95% confidence interval 1.39-3.53) and with a 3-fold increase in risk in women who were not enrolled in the intervention arm of any clinical trial (multivariable hazard ratio 3.15, 95% confidence interval 1.61-6.17). Glucose levels showed no association with risk. Analysis of the repeated measurements supported the results of the baseline analysis. These data suggest that elevated serum insulin levels may be a risk factor for postmenopausal breast cancer.

  13. Optimal selection of individuals for repeated covariate measurements in follow-up studies.

    Science.gov (United States)

    Reinikainen, Jaakko; Karvanen, Juha; Tolonen, Hanna

    2016-12-01

    Repeated covariate measurements bring important information on the time-varying risk factors in long epidemiological follow-up studies. However, due to budget limitations, it may be possible to carry out the repeated measurements only for a subset of the cohort. We study cost-efficient alternatives for the simple random sampling in the selection of the individuals to be remeasured. The proposed selection criteria are based on forms of the D-optimality. The selection methods are compared with the simulation studies and illustrated with the data from the East-West study carried out in Finland from 1959 to 1999. The results indicate that cost savings can be achieved if the selection is focused on the individuals with high expected risk of the event and, on the other hand, on those with extreme covariate values in the previous measurements. © The Author(s) 2014.

  14. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    Directory of Open Access Journals (Sweden)

    Leroux Aurélia A

    2012-10-01

    Full Text Available Abstract Background Pulsed wave (PW Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research.

  15. Mice repeatedly exposed to Group-A β-Haemolytic Streptococcus show perseverative behaviors, impaired sensorimotor gating, and immune activation in rostral diencephalon.

    Science.gov (United States)

    Macrì, Simone; Ceci, Chiara; Onori, Martina Proietti; Invernizzi, Roberto William; Bartolini, Erika; Altabella, Luisa; Canese, Rossella; Imperi, Monica; Orefici, Graziella; Creti, Roberta; Margarit, Immaculada; Magliozzi, Roberta; Laviola, Giovanni

    2015-08-25

    Repeated exposure to Group-A β-Haemolytic Streptococcus (GAS) may constitute a vulnerability factor in the onset and course of pediatric motor disturbances. GAS infections/colonization can stimulate the production of antibodies, which may cross the blood brain barrier, target selected brain areas (e.g. basal ganglia), and exacerbate motor alterations. Here, we exposed developing SJL male mice to four injections with a GAS homogenate and evaluated the following domains: motor coordination; general locomotion; repetitive behaviors; perseverative responses; and sensorimotor gating (pre-pulse inhibition, PPI). To demonstrate that behavioral changes were associated with immune-mediated brain alterations, we analyzed, in selected brain areas, the presence of infiltrates and microglial activation (immunohistochemistry), monoamines (HPLC), and brain metabolites (in vivo Magnetic Resonance Spectroscopy). GAS-exposed mice showed increased repetitive and perseverative behaviors, impaired PPI, and reduced concentrations of serotonin in prefrontal cortex, a brain area linked to the behavioral domains investigated, wherein they also showed remarkable elevations in lactate. Active inflammatory processes were substantiated by the observation of infiltrates and microglial activation in the white matter of the anterior diencephalon. These data support the hypothesis that repeated GAS exposure may elicit inflammatory responses in brain areas involved in motor control and perseverative behavior, and result in phenotypic abnormalities.

  16. Using the Monte Carlo Simulation Methods in Gauge Repeatability and Reproducibility of Measurement System Analysis

    Directory of Open Access Journals (Sweden)

    Tsu-Ming Yeh

    2013-10-01

    Full Text Available Measurements are required to maintain the consistent quality of all finished and semi-finished products in a production line. Many firms in the automobile and general precision industries apply the TS 16949:2009 Technical Specifications and Measurement System Analysis (MSA manual to establish measurement systems. This work is undertaken to evaluate gauge repeatability and reproducibility (GR&R to verify the measuring ability and quality of the measurement frame, as well as to continuously improve and maintain the verification process. Nevertheless, the implementation of GR&R requires considerable time and manpower, and is likely to affect production adversely. In addition, the evaluation value for GR&R is always different owing to the sum of man-made and machine-made variations. Using a Monte Carlo simulation and the prediction of the repeatability and reproducibility of the measurement system analysis, this study aims to determine the distribution of %GR&R and the related number of distinct categories (ndc. This study uses two case studies of an automobile parts manufacturer and the combination of a Monte Carlo simulation, statistical bases, and the prediction of the repeatability and reproducibility of the measurement system analysis to determine the probability density function, the distribution of %GR&R, and the related number of distinct categories (ndc. The method used in this study could evaluate effectively the possible range of the GR&R of the measurement capability, in order to establish a prediction model for the evaluation of the measurement capacity of a measurement system.

  17. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  18. Incomplete quality of life data in lung transplant research: comparing cross sectional, repeated measures ANOVA, and multi-level analysis

    Directory of Open Access Journals (Sweden)

    van der Bij Wim

    2005-09-01

    Full Text Available Abstract Background In longitudinal studies on Health Related Quality of Life (HRQL it frequently occurs that patients have one or more missing forms, which may cause bias, and reduce the sample size. Aims of the present study were to address the problem of missing data in the field of lung transplantation (LgTX and HRQL, to compare results obtained with different methods of analysis, and to show the value of each type of statistical method used to summarize data. Methods Results from cross-sectional analysis, repeated measures on complete cases (ANOVA, and a multi-level analysis were compared. The scores on the dimension 'energy' of the Nottingham Health Profile (NHP after transplantation were used to illustrate the differences between methods. Results Compared to repeated measures ANOVA, the cross-sectional and multi-level analysis included more patients, and allowed for a longer period of follow-up. In contrast to the cross sectional analyses, in the complete case analysis, and the multi-level analysis, the correlation between different time points was taken into account. Patterns over time of the three methods were comparable. In general, results from repeated measures ANOVA showed the most favorable energy scores, and results from the multi-level analysis the least favorable. Due to the separate subgroups per time point in the cross-sectional analysis, and the relatively small number of patients in the repeated measures ANOVA, inclusion of predictors was only possible in the multi-level analysis. Conclusion Results obtained with the various methods of analysis differed, indicating some reduction of bias took place. Multi-level analysis is a useful approach to study changes over time in a data set where missing data, to reduce bias, make efficient use of available data, and to include predictors, in studies concerning the effects of LgTX on HRQL.

  19. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  20. The canine prostate cancer cell line CHP-1 shows over-expression of the co-chaperone small glutamine-rich tetratricopeptide repeat-containing protein α.

    Science.gov (United States)

    Azakami, D; Nakahira, R; Kato, Y; Michishita, M; Kobayashi, M; Onozawa, E; Bonkobara, M; Kobayashi, M; Takahashi, K; Watanabe, M; Ishioka, K; Sako, T; Ochiai, K; Omi, T

    2017-06-01

    Although androgen therapy resistance and poor clinical outcomes are seen in most canine prostate cancer cases, there are only a few tools for analysing canine prostate cancer by using a cell biological approach. Therefore, to evaluate androgen-independent neoplastic cell growth, a new canine prostate cancer cell line (CHP-1) was established in this study. CHP-1 over-expressed the co-chaperone small glutamine-rich tetratricopeptide repeat-containing protein α (SGTA), which is over-expressed in human androgen-independent prostate cancer. The CHP-1 xenograft also showed SGTA over-expression. Although CHP-1 shows poor androgen receptor (AR) signalling upon dihydrotestosterone stimulation, forced expression of AR enabled evaluation of AR signalling. Taken together, these results suggest that CHP-1 will be a useful model for investigating the pathogenesis of androgen-dependent and androgen-independent canine prostate cancer. © 2016 John Wiley & Sons Ltd.

  1. Validity and repeatability of three in-shoe pressure measurement systems.

    Science.gov (United States)

    Price, Carina; Parker, Daniel; Nester, Christopher

    2016-05-01

    In-shoe pressure measurement devices are used in research and clinic to quantify plantar foot pressures. Various devices are available, differing in size, sensor number and type; therefore accuracy and repeatability. Three devices (Medilogic, Tekscan and Pedar) were examined in a 2 day×3 trial design, quantifying insole response to regional and whole insole loading. The whole insole protocol applied an even pressure (50-600kPa) to the insole surface for 0-30s in the Novel TruBlue™ device. The regional protocol utilised cylinders with contact surfaces of 3.14 and 15.9cm(2) to apply pressures of 50 and 200kPa. The validity (% difference and Root Mean Square Error: RMSE) and repeatability (Intra-Class Correlation Coefficient: ICC) of the applied pressures (whole insole) and contact area (regional) were outcome variables. Validity of the Pedar system was highest (RMSE 2.6kPa; difference 3.9%), with the Medilogic (RMSE 27.0kPa; difference 13.4%) and Tekscan (RMSE 27.0kPa; difference 5.9%) systems displaying reduced validity. The average and peak pressures demonstrated high between-day repeatability for all three systems and each insole size (ICC≥0.859). The regional contact area % difference ranged from -97 to +249%, but the ICC demonstrated medium to high between-day repeatability (ICC≥0.797). Due to the varying responses of the systems, the choice of an appropriate pressure measurement device must be based on the loading characteristics and the outcome variables sought. Medilogic and Tekscan were most effective between 200 and 300kPa; Pedar performed well across all pressures. Contact area was less precise, but relatively repeatable for all systems.

  2. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  3. On The Repeater Control to Achieve Goods Any Show Effect%Repeater控件实现商品的任何展示效果的研究

    Institute of Scientific and Technical Information of China (English)

    王得燕; 肖颖

    2011-01-01

    DataGrid、DataList和Repeater三个控件是ASP.NET的重要数据控件,通过数据源的设置。均可以用来显示数据,被大量用于WEB网页的设计过程中。文章对三个控件的异同做了研究,对看起来份量最轻但其实性能最好的Repeater控件进行深入研究,给出实现各种商品展示效果的程序设计方法。%Data Grid, Data List and Repeater are three important controls for ASP. NET data controls. By setting the data source, they can be used to display data and WEB pages design process. This article made some comparison on the similarities and differences between the three controls, and studied the Repeater control deeply and gave programs that achieve Any Show Effect of goods.

  4. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  5. Analysis of oligonucleotide array experiments with repeated measures using mixed models.

    Science.gov (United States)

    Li, Hao; Wood, Constance L; Getchell, Thomas V; Getchell, Marilyn L; Stromberg, Arnold J

    2004-12-30

    Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease) or absence (Control) of the disease, and brain regions including olfactory bulb (OB) or cerebellum (CER). In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH) procedure of controlling false discovery rate (FDR) at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the alpha-level (alphanew = 0.0033) determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD) procedure at the level of alphanew to control the family-wise error rate (FWER) for each gene examined. A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  6. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  7. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  8. On the repeated measures designs and sample sizes for randomized controlled trials.

    Science.gov (United States)

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials.

  9. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  10. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  11. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  12. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  13. [Repeated measurement of memory with valenced test items: verbal memory, working memory and autobiographic memory].

    Science.gov (United States)

    Kuffel, A; Terfehr, K; Uhlmann, C; Schreiner, J; Löwe, B; Spitzer, C; Wingenfeld, K

    2013-07-01

    A large number of questions in clinical and/or experimental neuropsychology require the multiple repetition of memory tests at relatively short intervals. Studies on the impact of the associated exercise and interference effects on the validity of the test results are rare. Moreover, hardly any neuropsychological instruments exist to date to record the memory performance with several parallel versions in which the emotional valence of the test material is also taken into consideration. The aim of the present study was to test whether a working memory test (WST, a digit-span task with neutral or negative distraction stimuli) devised by our workgroup can be used with repeated measurements. This question was also examined in parallel versions of a wordlist learning paradigm and an autobiographical memory test (AMT). Both tests contained stimuli with neutral, positive and negative valence. Twenty-four participants completed the memory testing including the working memory test and three versions of a wordlist and the AMT at intervals of a week apiece (measuring points 1. - 3.). The results reveal consistent performances across the three measuring points in the working and autobiographical memory test. The valence of the stimulus material did not influence the memory performance. In the delayed recall of the wordlist an improvement in memory performance over time was seen. The tests on working memory presented and the parallel versions for the declarative and autobiographical memory constitute informal economic instruments within the scope of the measurement repeatability designs. While the WST and AMT are appropriate for study designs with repeated measurements at relatively short intervals, longer intervals might seem more favourable for the use of wordlist learning paradigms. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Validity and repeatability of a depth camera-based surface imaging system for thigh volume measurement.

    Science.gov (United States)

    Bullas, Alice M; Choppin, Simon; Heller, Ben; Wheat, Jon

    2016-10-01

    Complex anthropometrics such as area and volume, can identify changes in body size and shape that are not detectable with traditional anthropometrics of lengths, breadths, skinfolds and girths. However, taking these complex with manual techniques (tape measurement and water displacement) is often unsuitable. Three-dimensional (3D) surface imaging systems are quick and accurate alternatives to manual techniques but their use is restricted by cost, complexity and limited access. We have developed a novel low-cost, accessible and portable 3D surface imaging system based on consumer depth cameras. The aim of this study was to determine the validity and repeatability of the system in the measurement of thigh volume. The thigh volumes of 36 participants were measured with the depth camera system and a high precision commercially available 3D surface imaging system (3dMD). The depth camera system used within this study is highly repeatable (technical error of measurement (TEM) of <1.0% intra-calibration and ~2.0% inter-calibration) but systematically overestimates (~6%) thigh volume when compared to the 3dMD system. This suggests poor agreement yet a close relationship, which once corrected can yield a usable thigh volume measurement.

  15. Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies.

    Science.gov (United States)

    Schall, Mark C; Fethke, Nathan B; Chen, Howard; Oyama, Sakiko; Douphrate, David I

    2016-04-01

    The accuracy and repeatability of an inertial measurement unit (IMU) system for directly measuring trunk angular displacement and upper arm elevation were evaluated over eight hours (i) in comparison to a gold standard, optical motion capture (OMC) system in a laboratory setting, and (ii) during a field-based assessment of dairy parlour work. Sample-to-sample root mean square differences between the IMU and OMC system ranged from 4.1° to 6.6° for the trunk and 7.2°-12.1° for the upper arm depending on the processing method. Estimates of mean angular displacement and angular displacement variation (difference between the 90th and 10th percentiles of angular displacement) were observed to change IMU system may serve as an acceptable instrument for directly measuring trunk and upper arm postures in field-based occupational exposure assessment studies with long sampling durations. Practitioner Summary: Few studies have evaluated inertial measurement unit (IMU) systems in the field or over long sampling durations. Results of this study indicate that the IMU system evaluated has reasonably good accuracy and repeatability for use in a field setting over a long sampling duration.

  16. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Hensley, Scott; Lou, Yunling; Rosen, Paul; Wheeler, Kevin; Zebker, Howard; Madsen, Soren; Miller, Tim; Hoffman, Jim; Farra, Don

    2003-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeat-pass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV) or minimally piloted vehicle (MPV). Upon surveying the capabilities and availabilities of such aircraft, the Proteus aircraft and the ALTAIR UAV appear to meet our criteria in terms of payload capabilities, flying altitude, and endurance. To support the repeat pass deformation capability it is necessary to control flight track capability of the aircraft to be within a specified 10 m tube with a goal of 1 m. This requires real-time GPS control of the autopilot to achieve these objectives that has not been demonstrated on these aircraft. Based on the Proteus and ALTAIR's altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and a 16 km range swath. The radar will have an active electronic beam steering antenna to achieve a Doppler centroid stability that is necessary for repeat-pass interferometry. This paper presents some of the trade studies for the platform, instrument and the expected science.

  17. Characterisation and measurement of signals generated by DVB-H 'GAP-filler' repeaters.

    Science.gov (United States)

    Baldini, M; Barellini, A; Bogi, L; Licitra, G; Silvi, A M; Zari, A

    2009-12-01

    DVB-H (Digital Video Broadcasting Handheld) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains.

  18. Measuring the Activity of Leucine-Rich Repeat Kinase 2: A Kinase Involved in Parkinson's Disease

    Science.gov (United States)

    Lee, Byoung Dae; Li, Xiaojie; Dawson, Ted M.; Dawson, Valina L.

    2015-01-01

    Mutations in the LRRK2 (Leucine-Rich Repeat Kinase 2) gene are the most common cause of autosomal dominant Parkinson's disease. LRRK2 has multiple functional domains including a kinase domain. The kinase activity of LRRK2 is implicated in the pathogenesis of Parkinson's disease. Developing an assay to understand the mechanisms of LRRK2 kinase activity is important for the development of pharmacologic and therapeutic applications. Here, we describe how to measure in vitro LRRK2 kinase activity and its inhibition. PMID:21960214

  19. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  20. Repeatability and Accuracy of Exoplanet Eclipse Depths Measured with Post-Cryogenic Spitzer

    CERN Document Server

    Ingalls, James G; Carey, S J; Stauffer, John R; Lawrence, Patrick J; Grillmair, Carl J; Buzasi, Derek; Deming, Drake; Diamond-Lowe, Hannah; Evans, Thomas M; Morello, G; Stevenson, Kevin B; Wong, Ian; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa

    2016-01-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5{\\mu}m dataset, consisting of 10 observations of the XO-3 b system during secondary eclipse, using 7 different techniques for removing correlated noise. We find that, on average, for a given technique the eclipse depth estimate is repeatable from epoch to epoch to within 150 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 2 of the photon noise limit. Nearly all methods accurately assess their own errors: for these methods the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10-epoch sample. To assess the accuracy of the techniques as well as clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated datas...

  1. Force spectroscopy measurements show that cortical neurons exposed to excitotoxic agonists stiffen before showing evidence of bleb damage.

    Directory of Open Access Journals (Sweden)

    Shan Zou

    Full Text Available In ischemic and traumatic brain injury, hyperactivated glutamate (N-methyl-D-aspartic acid, NMDA and sodium (Nav channels trigger excitotoxic neuron death. Na(+, Ca(++ and H2O influx into affected neurons elicits swelling (increased cell volume and pathological blebbing (disassociation of the plasma membrane's bilayer from its spectrin-actomyosin matrix. Though usually conflated in injured tissue, cell swelling and blebbing are distinct processes. Around an injury core, salvageable neurons could be mildly swollen without yet having suffered the bleb-type membrane damage that, by rendering channels leaky and pumps dysfunctional, exacerbates the excitotoxic positive feedback spiral. Recognizing when neuronal inflation signifies non-lethal osmotic swelling versus blebbing should further efforts to salvage injury-penumbra neurons. To assess whether the mechanical properties of osmotically-swollen versus excitotoxically-blebbing neurons might be cytomechanically distinguishable, we measured cortical neuron elasticity (gauged via atomic force microscopy (AFM-based force spectroscopy upon brief exposure to hypotonicity or to excitotoxic agonists (glutamate and Nav channel activators, NMDA and veratridine. Though unperturbed by solution exchange per se, elasticity increased abruptly with hypotonicity, with NMDA and with veratridine. Neurons then invariably softened towards or below the pre-treatment level, sometimes starting before the washout. The initial channel-mediated stiffening bespeaks an abrupt elevation of hydrostatic pressure linked to NMDA or Nav channel-mediated ion/H2O fluxes, together with increased [Ca(++]int-mediated submembrane actomyosin contractility. The subsequent softening to below-control levels is consistent with the onset of a lethal level of bleb damage. These findings indicate that dissection/identification of molecular events during the excitotoxic transition from stiff/swollen to soft/blebbing is warranted and should be

  2. Measuring the Dynamic Soil Response During Repeated Wheeling Using Seismic Methods

    DEFF Research Database (Denmark)

    Keller, Thomas; Carizzon, Marco; Berisso, Feto Esimo

    2013-01-01

    Our understanding of soil deformation processes, especially its dynamics, remains limited. This hampers accurate predictions of the impact of soil management practices such as agricultural field traffic on (physical) soil functions. The main objective of this study was to investigate whether...... seismic measurements could be used to assess the dynamic soil behavior during repeated loading. Moreover, we aimed at linking the velocity of P-waves, Vp, to traditionally measured soil properties associated with soil compaction, namely bulk density (ρb) and penetrometer resistance. A wheeling experiment......, and simulated the evolution of bulk density due to the wheeling using a soil compaction model. The dynamic soil response during loading–unloading–reloading cycles could be well captured with the seismic method. The measured Vp related to bulk density, and the compaction-induced increase in Vp correlated...

  3. Information Contents of a Signal at Repeated Positioning Measurements of the Coordinate Measuring Machine (CMM by Laser Interferometer

    Directory of Open Access Journals (Sweden)

    Stejskal Tomáš

    2016-10-01

    Full Text Available The input of this paper lies in displaying possibilities how to determine the condition of a coordinate measuring machine (CMM based on a large number of repeated measurements. The number of repeated measurements exceeds common requirements for determining positioning accuracy. The total offset in the accuracy of spatial positioning consists of partial inaccuracies of individual axes. 6 basic errors may be defined at each axis. In a triaxial set, that translates into 18 errors, to which an offset from the perpendicularity between the axial pairs must be added. Therefore, the combined number of errors in a single position is 21. These errors are systemic and stem from the machine’s geometry. In addition, there are accidental errors to account for as well. Accidental errors can be attributed to vibrations, mass inertness, passive resistance, and in part to fluctuations in temperature. A peculiar set of systemic errors are time-varying errors. The nature of those errors may be reversible, for instance if they result from influence of temperature or elastic deformation. They can be also irreversible, for example as a result of wear and tear or line clogging, due to loosened connection or permanent deformation of a part post collision. A demonstration of thermal equalizing of the machine’s parts may also be observed in case of failure to adhere to a sufficient time interval from the moment the air-conditioning is turned on. Repeated measurements done on a selected axis with linear interferometer can provide complex information on the CMM condition and also on the machine’s interaction with the given technical environment.

  4. Persistent repeated measurements by magnetic resonance spectroscopy demonstrate minimal hepatic encephalopathy: a case report.

    Science.gov (United States)

    Scheau, C; Popa, G A; Ghergus, A E; Preda, E M; Capsa, R A; Lupescu, I G

    2013-09-15

    Minimal Hepatic Encephalopathy (MHE), previously referred to as infraclinical or subclinical is a precursor in the development of clinical hepatic encephalopathy (HE). The demonstration of MHE is done through neuropsychological testing in the absence of clinical evidence of HE, patients showing only a mild cognitive impairment. Neuropsychological tests employed consist of Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) and portosystemic encephalopathy (PSE) test score. Unfortunately, there are numerous occasions when the tests prove irrelevant: in the situation of inexperienced investigators, the patient's poor education, vision problems or concurring central nervous system disease, all of which may delay or deviate from the correct diagnosis.

  5. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  6. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability.

    Science.gov (United States)

    Sousa, Filipe; Dos Reis, Ivan; Ribeiro, Luiz; Martins, Luiz; Gobatto, Claudio

    2015-12-22

    Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s) completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35). Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p sprint ability than the other studied variables.

  7. On the Analysis of a Repeated Measure Design in Genome-Wide Association Analysis

    Directory of Open Access Journals (Sweden)

    Young Lee

    2014-11-01

    Full Text Available Longitudinal data enables detecting the effect of aging/time, and as a repeated measures design is statistically more efficient compared to cross-sectional data if the correlations between repeated measurements are not large. In particular, when genotyping cost is more expensive than phenotyping cost, the collection of longitudinal data can be an efficient strategy for genetic association analysis. However, in spite of these advantages, genome-wide association studies (GWAS with longitudinal data have rarely been analyzed taking this into account. In this report, we calculate the required sample size to achieve 80% power at the genome-wide significance level for both longitudinal and cross-sectional data, and compare their statistical efficiency. Furthermore, we analyzed the GWAS of eight phenotypes with three observations on each individual in the Korean Association Resource (KARE. A linear mixed model allowing for the correlations between observations for each individual was applied to analyze the longitudinal data, and linear regression was used to analyze the first observation on each individual as cross-sectional data. We found 12 novel genome-wide significant disease susceptibility loci that were then confirmed in the Health Examination cohort, as well as some significant interactions between age/sex and SNPs.

  8. Multiple-objective response-adaptive repeated measurement designs in clinical trials for binary responses.

    Science.gov (United States)

    Liang, Yuanyuan; Li, Yin; Wang, Jing; Carriere, Keumhee C

    2014-02-20

    A multiple-objective allocation strategy was recently proposed for constructing response-adaptive repeated measurement designs for continuous responses. We extend the allocation strategy to constructing response-adaptive repeated measurement designs for binary responses. The approach with binary responses is quite different from the continuous case, as the information matrix is a function of responses, and it involves nonlinear modeling. To deal with these problems, we first build the design on the basis of success probabilities. Then we illustrate how various models can accommodate carryover effects on the basis of logits of response profiles as well as any correlation structure. Through computer simulations, we find that the allocation strategy developed for continuous responses also works well for binary responses. As expected, design efficiency in terms of mean squared error drops sharply, as more emphasis is placed on increasing treatment benefit than estimation precision. However, we find that it can successfully allocate more patients to better treatment sequences without sacrificing much estimation precision.

  9. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg

    Science.gov (United States)

    van Zantvoort, Aniek P. M.; de Bruijn, Johan A.; Winkes, Michiel B.; Hoogeveen, Adwin R.; Teijink, Joep A. W.; Scheltinga, Marc R.

    2017-01-01

    Background: The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. Purpose: To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Study Design: Case series; Level of evidence, 4. Methods: Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. Results: A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ2 = 1.928, P = .381). Sex (χ2 = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ2 = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15

  10. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg.

    Science.gov (United States)

    van Zantvoort, Aniek P M; de Bruijn, Johan A; Winkes, Michiel B; Hoogeveen, Adwin R; Teijink, Joep A W; Scheltinga, Marc R

    2017-06-01

    The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Case series; Level of evidence, 4. Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ(2) = 1.928, P = .381). Sex (χ(2) = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ(2) = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15 patients [53% female]; mean age, 31 ± 10 years

  11. New species of Ehrlichia isolated from Rhipicephalus (Boophilus microplus shows an ortholog of the E. canis major immunogenic glycoprotein gp36 with a new sequence of tandem repeats

    Directory of Open Access Journals (Sweden)

    Cruz Alejandro Cabezas

    2012-12-01

    Full Text Available Abstract Background Ehrlichia species are the etiological agents of emerging and life-threatening tick-borne human zoonoses that inflict serious and fatal infections in companion animals and livestock. The aim of this paper was to phylogeneticaly characterise a new species of Ehrlichia isolated from Rhipicephalus (Boophilus microplus from Minas Gerais, Brazil. Methods The agent was isolated from the hemolymph of Rhipicephalus (B. microplus engorged females that had been collected from naturally infested cattle in a farm in the state of Minas Gerais, Brazil. This agent was then established and cultured in IDE8 tick cells. The molecular and phylogenetic analysis was based on 16S rRNA, groEL, dsb, gltA and gp36 genes. We used the maximum likelihood method to construct the phylogenetic trees. Results The phylogenetic trees based on 16S rRNA, groEL, dsb and gltA showed that the Ehrlichia spp isolated in this study falls in a clade separated from any previously reported Ehrlichia spp. The molecular analysis of the ortholog of gp36, the major immunoreactive glycoproteins in E. canis and ortholog of the E. chaffeensis gp47, showed a unique tandem repeat of 9 amino acids (VPAASGDAQ when compared with those reported for E. canis, E. chaffeensis and the related mucin-like protein in E. ruminantium. Conclusions Based on the molecular and phylogenetic analysis of the 16S rRNA, groEL, dsb and gltA genes we concluded that this tick-derived microorganism isolated in Brazil is a new species, named E. mineirensis (UFMG-EV, with predicted novel antigenic properties in the gp36 ortholog glycoprotein. Further studies on this new Ehrlichia spp should address questions about its transmissibility by ticks and its pathogenicity for mammalian hosts.

  12. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  13. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  14. Impact of repeated measures and sample selection on genome-wide association studies of fasting glucose

    Science.gov (United States)

    Rasmussen-Torvik, Laura J.; Alonso, Alvaro; Li, Man; Kao, Wen; Köttgen, Anna; Yan, Yuer; Couper, David; Boerwinkle, Eric; Bielinski, Suzette J.; Pankow, James S.

    2010-01-01

    Although GWAS have been performed in longitudinal studies, most used only a single trait measure. GWAS of fasting glucose have generally included only normoglycemic individuals. We examined the impact of both repeated measures and sample selection on GWAS in ARIC, a study which obtained four longitudinal measures of fasting glucose and included both individuals with and without prevalent diabetes. The sample included Caucasians and the Affymetrix 6.0 chip was used for genotyping. Sample sizes for GWAS analyses ranged from 8372 (first study visit) to 5782 (average fasting glucose). Candidate SNP analyses with SNPs identified through fasting glucose or diabetes GWAS were conducted in 9133 individuals, including 761 with prevalent diabetes. For a constant sample size, smaller p-values were obtained for the average measure of fasting glucose compared to values at any single visit, and two additional significant GWAS signals were detected. For four candidate SNPs (rs780094, rs10830963, rs7903146, and rs4607517), the strength of association between genotype and glucose was significantly (p-interaction fasting glucose candidate SNPs (rs780094, rs10830963, rs560887, rs4607517, rs13266634) the association with measured fasting glucose was more significant in the smaller sample without prevalent diabetes than in the larger combined sample of those with and without diabetes. This analysis demonstrates the potential utility of averaging trait values in GWAS studies and explores the advantage of using only individuals without prevalent diabetes in GWAS of fasting glucose. PMID:20839289

  15. How integrated are behavioral and endocrine stress response traits? A repeated measures approach to testing the stress-coping style model.

    Science.gov (United States)

    Boulton, Kay; Couto, Elsa; Grimmer, Andrew J; Earley, Ryan L; Canario, Adelino V M; Wilson, Alastair J; Walling, Craig A

    2015-02-01

    It is widely expected that physiological and behavioral stress responses will be integrated within divergent stress-coping styles (SCS) and that these may represent opposite ends of a continuously varying reactive-proactive axis. If such a model is valid, then stress response traits should be repeatable and physiological and behavioral responses should also change in an integrated manner along a major axis of among-individual variation. While there is some evidence of association between endocrine and behavioral stress response traits, few studies incorporate repeated observations of both. To test this model, we use a multivariate, repeated measures approach in a captive-bred population of Xiphophorus birchmanni. We quantify among-individual variation in behavioral stress response to an open field trial (OFT) with simulated predator attack (SPA) and measure waterborne steroid hormone levels (cortisol, 11-ketotestosterone) before and after exposure. Under the mild stress stimulus (OFT), (multivariate) behavioral variation among individuals was consistent with a strong axis of personality (shy-bold) or coping style (reactive-proactive) variation. However, behavioral responses to a moderate stressor (SPA) were less repeatable, and robust statistical support for repeatable endocrine state over the full sampling period was limited to 11-ketotestosterone. Although post hoc analysis suggested cortisol expression was repeatable over short time periods, qualitative relationships between behavior and glucocorticoid levels were counter to our a priori expectations. Thus, while our results clearly show among-individual differences in behavioral and endocrine traits associated with stress response, the correlation structure between these is not consistent with a simple proactive-reactive axis of integrated stress-coping style. Additionally, the low repeatability of cortisol suggests caution is warranted if single observations (or indeed repeat measures over short sampling

  16. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms

    Directory of Open Access Journals (Sweden)

    Clark Kogan

    2016-01-01

    Full Text Available In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  17. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms.

    Science.gov (United States)

    Kogan, Clark; Kalachev, Leonid; Van Dongen, Hans P A

    2016-01-01

    In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables) by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary) response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  18. Estimation of the concordance correlation coefficient for repeated measures using SAS and R.

    Science.gov (United States)

    Carrasco, Josep L; Phillips, Brenda R; Puig-Martinez, Josep; King, Tonya S; Chinchilli, Vernon M

    2013-03-01

    The concordance correlation coefficient is one of the most common approaches used to assess agreement among different observers or instruments when the outcome of interest is a continuous variable. A SAS macro and R package are provided here to estimate the concordance correlation coefficient (CCC) where the design of the data involves repeated measurements by subject and observer. The CCC is estimated using U-statistics (UST) and variance components (VC) approaches. Confidence intervals and standard errors are reported along with the point estimate of the CCC. In the case of the VC approach, the linear mixed model output and variance components estimates are also provided. The performance of each function is shown by means of some examples with real data sets.

  19. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...... patterns estimated in RM-APIM. Interpretation of results from these models largely focuses on the meaning of single-parameter estimates in isolation from all the others. However, considering individual coefficients separately impedes the understanding of how these associations combine to produce...... to improve the understanding and presentation of dyadic patterns of association described by standard RM-APIMs. The current article briefly reviews the conceptual foundations of RM-APIMs, demonstrates how change-as-outcome RM-APIMs and VFDs can aid interpretation of standard RM-APIMs, and provides a tutorial...

  20. Inmate responses to prison-based drug treatment: a repeated measures analysis.

    Science.gov (United States)

    Welsh, Wayne N

    2010-06-01

    Using a sample of 347 prison inmates and general linear modeling (GLM) repeated measures analyses, this paper examined during-treatment responses (e.g., changes in psychological and social functioning) to prison-based TC drug treatment. These effects have rarely been examined in previous studies, and never with a fully multivariate model accounting for within-subjects effects (changes over time), between-subjects effects (e.g., levels of risk and motivation), and within/between-subjects interactions (timexriskxmotivation). The results provide evidence of positive inmate change in response to prison TC treatment, but the patterns of results varied depending upon: (a) specific indicators of psychological and social functioning, motivation, and treatment process; (b) the time periods examined (1, 6, and 12 months during treatment); and (c) baseline levels of risk and motivation. Significant interactions between time and type of inmate suggest important new directions for research, theory, and practice in offender-based substance abuse treatment.

  1. Bayesian latent variable models for hierarchical clustered count outcomes with repeated measures in microbiome studies.

    Science.gov (United States)

    Xu, Lizhen; Paterson, Andrew D; Xu, Wei

    2017-04-01

    Motivated by the multivariate nature of microbiome data with hierarchical taxonomic clusters, counts that are often skewed and zero inflated, and repeated measures, we propose a Bayesian latent variable methodology to jointly model multiple operational taxonomic units within a single taxonomic cluster. This novel method can incorporate both negative binomial and zero-inflated negative binomial responses, and can account for serial and familial correlations. We develop a Markov chain Monte Carlo algorithm that is built on a data augmentation scheme using Pólya-Gamma random variables. Hierarchical centering and parameter expansion techniques are also used to improve the convergence of the Markov chain. We evaluate the performance of our proposed method through extensive simulations. We also apply our method to a human microbiome study.

  2. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  3. Causal inference in longitudinal comparative effectiveness studies with repeated measures of a continuous intermediate variable.

    Science.gov (United States)

    Wang, Chen-Pin; Jo, Booil; Brown, C Hendricks

    2014-09-10

    We propose a principal stratification approach to assess causal effects in nonrandomized longitudinal comparative effectiveness studies with a binary endpoint outcome and repeated measures of a continuous intermediate variable. Our method is an extension of the principal stratification approach originally proposed for the longitudinal randomized study "Prevention of Suicide in Primary Care Elderly: Collaborative Trial" to assess the treatment effect on the continuous Hamilton depression score adjusting for the heterogeneity of repeatedly measured binary compliance status. Our motivation for this work comes from a comparison of the effect of two glucose-lowering medications on a clinical cohort of patients with type 2 diabetes. Here, we consider a causal inference problem assessing how well the two medications work relative to one another on two binary endpoint outcomes: cardiovascular disease-related hospitalization and all-cause mortality. Clinically, these glucose-lowering medications can have differential effects on the intermediate outcome, glucose level over time. Ultimately, we want to compare medication effects on the endpoint outcomes among individuals in the same glucose trajectory stratum while accounting for the heterogeneity in baseline covariates (i.e., to obtain 'principal effects' on the endpoint outcomes). The proposed method involves a three-step model estimation procedure. Step 1 identifies principal strata associated with the intermediate variable using hybrid growth mixture modeling analyses. Step 2 obtains the stratum membership using the pseudoclass technique and derives propensity scores for treatment assignment. Step 3 obtains the stratum-specific treatment effect on the endpoint outcome weighted by inverse propensity probabilities derived from Step 2.

  4. The clinical applicability of a daily summary of patients' self-reported postoperative pain-A repeated measure analysis.

    Science.gov (United States)

    Wikström, Lotta; Eriksson, Kerstin; Fridlund, Bengt; Nilsson, Mats; Årestedt, Kristofer; Broström, Anders

    2017-03-23

    (i) To determine whether a central tendency, median, based on patients' self-rated pain is a clinically applicable daily measure to show patients' postoperative pain on the first day after major surgery (ii) and to determine the number of self-ratings required for the calculation of this measure. Perioperative pain traits in medical records are difficult to overview. The clinical applicability of a daily documented summarising measure of patients' self-rated pain scores is little explored. A repeated measure design was carried out at three Swedish country hospitals. Associations between the measures were analysed with nonparametric statistical methods; systematic and individual group changes were analysed separately. Measure I: pain scores at rest and activity postoperative day 1; measure II: retrospective average pain from postoperative day 1. The sample consisted of 190 general surgery patients and 289 orthopaedic surgery patients with a mean age of 65; 56% were men. Forty-four percent had a pre-operative daily intake of analgesia, and 77% used postoperative opioids. A range of 4-9 pain scores seem to be eligible for the calculation of the daily measures of pain. Rank correlations for individual median scores, based on four ratings, vs. retrospective self-rated average pain, were moderate and strengthened with increased numbers of ratings. A systematic group change towards a higher level of reported retrospective pain was significant. The median values were clinically applicable daily measures. The risk of obtaining a higher value than was recalled by patients seemed to be low. Applicability increased with increased frequency of self-rated pain scores and with high-quality pain assessments. The documenting of daily median pain scores at rest and during activity could constitute the basis for obtaining patients' experiences by showing their pain severity trajectories. The measures could also be an important key to predicting postoperative health

  5. Intergenic and repeat transcription in human, chimpanzee and macaque brains measured by RNA-Seq.

    Directory of Open Access Journals (Sweden)

    Augix Guohua Xu

    Full Text Available Transcription is the first step connecting genetic information with an organism's phenotype. While expression of annotated genes in the human brain has been characterized extensively, our knowledge about the scope and the conservation of transcripts located outside of the known genes' boundaries is limited. Here, we use high-throughput transcriptome sequencing (RNA-Seq to characterize the total non-ribosomal transcriptome of human, chimpanzee, and rhesus macaque brain. In all species, only 20-28% of non-ribosomal transcripts correspond to annotated exons and 20-23% to introns. By contrast, transcripts originating within intronic and intergenic repetitive sequences constitute 40-48% of the total brain transcriptome. Notably, some repeat families show elevated transcription. In non-repetitive intergenic regions, we identify and characterize 1,093 distinct regions highly expressed in the human brain. These regions are conserved at the RNA expression level across primates studied and at the DNA sequence level across mammals. A large proportion of these transcripts (20% represents 3'UTR extensions of known genes and may play roles in alternative microRNA-directed regulation. Finally, we show that while transcriptome divergence between species increases with evolutionary time, intergenic transcripts show more expression differences among species and exons show less. Our results show that many yet uncharacterized evolutionary conserved transcripts exist in the human brain. Some of these transcripts may play roles in transcriptional regulation and contribute to evolution of human-specific phenotypic traits.

  6. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  7. Mice repeatedly exposed to Group-A β-Haemolytic Streptococcus show perseverative behaviors, impaired sensorimotor gating, and immune activation in rostral diencephalon

    OpenAIRE

    Simone Macrì; Chiara Ceci; Martina Proietti Onori; Roberto William Invernizzi; Erika Bartolini; Luisa Altabella; Rossella Canese; Monica Imperi; Graziella Orefici; Roberta Creti; Immaculada Margarit; Roberta Magliozzi; Giovanni Laviola

    2015-01-01

    Repeated exposure to Group-A β-Haemolytic Streptococcus (GAS) may constitute a vulnerability factor in the onset and course of pediatric motor disturbances. GAS infections/colonization can stimulate the production of antibodies, which may cross the blood brain barrier, target selected brain areas (e.g. basal ganglia), and exacerbate motor alterations. Here, we exposed developing SJL male mice to four injections with a GAS homogenate and evaluated the following domains: motor coordination; gen...

  8. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate....... Our study suggests that the blood transcriptome of healthy individuals is reproducible over a time period of several months. © 2013 Elsevier Inc....

  9. Status of a UAVSAR designed for repeat pass interferometry for deformation measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Sadowy, Greg; Miller, Tim; Shaffer, Scott; Muellerschoen, Ron; Jones, Cathleen; Zebker, Howard; Madsen, Soren; Paul, Rose

    2005-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also known as differential interferometric measurements. Differential interferometry can provide key deformation measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The expected performance of the flight control system will constrain the flight path to be within a 10 m diameter tube about the desired flight track. The radar wilI be designed to operate on a UAV (Unpiloted Aria1 Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus buitt by Scaled Composites or on a NASA Gulfstream III. The radar design is a fully polarimetric with an 80 MHz bandwidth (2 m range resolution) and 16 km range swath. The antenna is an electronically steered along track to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. Other features supported by the antenna include an elevation monopulse option and a pulse-to-pulse resteering capability that will enable some novel modes of operation. The system will nominally operate at 45,000 ft (13800 m). The program began out as an Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  10. Effects of CAG repeat length, HTT protein length and protein context on cerebral metabolism measured using magnetic resonance spectroscopy in transgenic mouse models of Huntington's disease.

    Science.gov (United States)

    Jenkins, Bruce G; Andreassen, Ole A; Dedeoglu, Alpaslan; Leavitt, Blair; Hayden, Michael; Borchelt, David; Ross, Christopher A; Ferrante, Robert J; Beal, M Flint

    2005-10-01

    Huntington's disease is a neurodegenerative illness caused by expansion of CAG repeats at the N-terminal end of the protein huntingtin. We examined longitudinal changes in brain metabolite levels using in vivo magnetic resonance spectroscopy in five different mouse models. There was a large (>50%) exponential decrease in N-acetyl aspartate (NAA) with time in both striatum and cortex in mice with 150 CAG repeats (R6/2 strain). There was a linear decrease restricted to striatum in N171-82Q mice with 82 CAG repeats. Both the exponential and linear decreases of NAA were paralleled in time by decreases in neuronal area measured histologically. Yeast artificial chromosome transgenic mice with 72 CAG repeats, but low expression levels, had less striatal NAA loss than the N171-82Q mice (15% vs. 43%). We evaluated the effect of gene context in mice with an approximate 146 CAG repeat on the hypoxanthine phosphoribosyltransferase gene (HPRT). HPRT mice developed an obese phenotype in contrast to weight loss in the R6/2 and N171-82Q mice. These mice showed a small striatal NAA loss (21%), and a possible increase in brain lipids detectable by magnetic resonance (MR) spectroscopy and decreased brain water T1. Our results indicate profound metabolic defects that are strongly affected by CAG repeat length, as well as gene expression levels and protein context.

  11. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Ppressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  12. Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2017-01-01

    Full Text Available Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France. Three consecutive measurements were obtained. The within-subject standard deviation (Sw, intrasubject precision (1.96×Sw, and intraclass correlation coefficient (ICC were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689. Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.

  13. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  14. Constructing Measure by Repeated Infinite Subdivision%通过反复无限细分定义测度

    Institute of Scientific and Technical Information of China (English)

    严质彬

    2005-01-01

    This paper generalizes the method of constructing measure by repeated finite subdivision in fTactal geometry to that by infinite subdivision. Two conditions for the existing method are removed. A measure on the interval [0, 1] is constructed using this generalized method.

  15. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure, choles

  16. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure,

  17. NMR shows hydrophobic interactions replace glycine packing in the triple helix at a natural break in the (Gly-X-Y)n repeat.

    Science.gov (United States)

    Li, Yingjie; Brodsky, Barbara; Baum, Jean

    2007-08-03

    Little is known about the structural consequences of the more than 20 breaks in the (Gly-X-Y)(n) repeating sequence found in the long triple helix domain of basement membrane type IV collagen. NMR triple resonance studies of doubly labeled residues within a set of collagen model peptides provide distance and dihedral angle restraints that allow determination of model structures of both a standard triple helix and of a triple helix with a break in solution. Although the standard triple helix cannot continue when Gly is not every third residue, the NMR data support rod-like molecules that have standard triple-helical structures on both sides of a well defined and highly localized perturbation. The GAAVM break region may be described as a "pseudo triple helix," because it preserves the standard one-residue stagger of the triple helix but introduces hydrophobic interactions at the position normally occupied by the much smaller and hydrogen-bonded Gly residue of the repeating (Gly-X-Y)(n) sequence. This structure provides a rationale for the consensus presence of hydrophobic residues in breaks of similar length and defines a novel variant of a triple helix that could be involved in recognition.

  18. Two novel DXZ4-associated long noncoding RNAs show developmental changes in expression coincident with heterochromatin formation at the human (Homo sapiens) macrosatellite repeat.

    Science.gov (United States)

    Figueroa, Debbie M; Darrow, Emily M; Chadwick, Brian P

    2015-12-01

    On the male X and female active X chromosome (Xa), the macrosatellite repeat (MSR) DXZ4 is packaged into constitutive heterochromatin characterized by CpG methylation and histone H3 tri-methylated at lysine-9 (H3K9me3). In contrast, DXZ4 on the female inactive X chromosome (Xi), is packaged into euchromatin, is bound by the architectural protein CCCTC-binding factor, and mediates Xi-specific long-range cis contact with similarly packaged tandem repeats on the Xi. In cancer, male DXZ4 can inappropriately revert to a Xi-like state and other MSRs have been reported to adopt alternate chromatin configurations in response to disease. Given this plasticity, we sought to identify factors that might control heterochromatin at DXZ4. In human embryonic stem cells, we found low levels of 5-hydroxymethylcytosine at DXZ4 and that this mark is lost upon differentiation as H3K9me3 is acquired. We identified two previously undescribed DXZ4 associated noncoding transcripts (DANT1 and DANT2) that are transcribed toward DXZ4 from promoters flanking the array. Each generates transcript isoforms that traverse the MSR. However, upon differentiation, enhancer of Zeste-2 silences DANT1, and DANT2 transcription terminates prior to entering DXZ4. These data support a model wherein DANT1 and/or DANT2 may function to regulate constitutive heterochromatin formation at this MSR.

  19. Two novel DXZ4-associated long noncoding RNAs show developmental changes in expression coincident with heterochromatin formation at the human (Homo sapiens) macrosatellite repeat

    Science.gov (United States)

    Figueroa, Debbie M.; Darrow, Emily M.; Chadwick, Brian P.

    2015-01-01

    On the male X and female active X chromosome (Xa), the macrosatellite repeat (MSR) DXZ4 is packaged into constitutive heterochromatin characterized by CpG methylation and histone H3 tri-methylated at lysine-9 (H3K9me3). In contrast, DXZ4 on the female inactive X chromosome (Xi), is packaged into euchromatin, is bound by the architectural protein CCCTC-binding factor, and mediates Xi-specific long-range cis contact with similarly packaged tandem repeats on the Xi. In cancer, male DXZ4 can inappropriately revert to a Xi-like state and other MSRs have been reported to adopt alternate chromatin configurations in response to disease. Given this plasticity, we sought to identify factors that might control heterochromatin at DXZ4. In human embryonic stem cells, we found low levels of 5-hydroxymethylcytosine at DXZ4, and that this mark is lost upon differentiation as H3K9me3 is acquired. We identified two previously undescribed DXZ4 associated non-coding transcripts (DANT1 and DANT2) that are transcribed towards DXZ4 from promoters flanking the array. Each generates transcript isoforms that traverse the MSR. However, upon differentiation, Enhancer of Zeste-2 silences DANT1, and DANT2 transcription terminates prior to entering DXZ4. These data support a model wherein DANT1 and/or DANT2 may function to regulate constitutive heterochromatin formation at this MSR. PMID:26188586

  20. Measuring risk attitudes in a natural experiment: Data from the television game show Lingo

    NARCIS (Netherlands)

    Beetsma, R.M.W.J.; Schotman, P.C.

    2001-01-01

    We use data from a television game show involving elementary lotteries as a natural experiment to measure risk attitudes. Unique features of our data set are the substantial monetary stakes and the large sample size. CRRA and CARA utility specifications perform approximately equally well. We find ro

  1. Measuring risk attitudes in a natural experiment: Data from the television game show LINGO

    NARCIS (Netherlands)

    Beetsma, R.M.W.J.; Schotman, P.C.

    1998-01-01

    We use data from a television game show, involving elementary lotteries and substantial prize money, as a natural experiment to measure risk attitudes. We find robust evidence of substantial risk aversion. As an extension, we estimate the various models using transformations of the 'true' probabilit

  2. Tracking photon jumps with repeated quantum non-demolition parity measurements.

    Science.gov (United States)

    Sun, L; Petrenko, A; Leghtas, Z; Vlastakis, B; Kirchmair, G; Sliwa, K M; Narla, A; Hatridge, M; Shankar, S; Blumoff, J; Frunzio, L; Mirrahimi, M; Devoret, M H; Schoelkopf, R J

    2014-07-24

    Quantum error correction is required for a practical quantum computer because of the fragile nature of quantum information. In quantum error correction, information is redundantly stored in a large quantum state space and one or more observables must be monitored to reveal the occurrence of an error, without disturbing the information encoded in an unknown quantum state. Such observables, typically multi-quantum-bit parities, must correspond to a special symmetry property inherent in the encoding scheme. Measurements of these observables, or error syndromes, must also be performed in a quantum non-demolition way (projecting without further perturbing the state) and more quickly than errors occur. Previously, quantum non-demolition measurements of quantum jumps between states of well-defined energy have been performed in systems such as trapped ions, electrons, cavity quantum electrodynamics, nitrogen-vacancy centres and superconducting quantum bits. So far, however, no fast and repeated monitoring of an error syndrome has been achieved. Here we track the quantum jumps of a possible error syndrome, namely the photon number parity of a microwave cavity, by mapping this property onto an ancilla quantum bit, whose only role is to facilitate quantum state manipulation and measurement. This quantity is just the error syndrome required in a recently proposed scheme for a hardware-efficient protected quantum memory using Schrödinger cat states (quantum superpositions of different coherent states of light) in a harmonic oscillator. We demonstrate the projective nature of this measurement onto a region of state space with well-defined parity by observing the collapse of a coherent state onto even or odd cat states. The measurement is fast compared with the cavity lifetime, has a high single-shot fidelity and has a 99.8 per cent probability per single measurement of leaving the parity unchanged. In combination with the deterministic encoding of quantum information in cat

  3. Assessing variability and comparing short-term biomarkers of styrene exposure using a repeated measurements approach.

    Science.gov (United States)

    Fustinoni, S; Manini, P; Campo, L; De Palma, G; Andreoli, R; Mutti, A; Bertazzi, P A; Rappaport, S M

    2010-01-15

    The aim of this work is to compare several short-term biomarkers of styrene exposure, namely urinary styrene (StyU), mercapturic acids (M1+M2), mandelic acid (MA), phenylglyoxylic acid (PGA), phenylglycine (PHG), and 4-vinylphenol conjugates (VP), for use as biomarkers of exposure in epidemiologic studies. A repeated measurements protocol (typically 4 measurements per worker over 6 weeks) was applied to measure airborne styrene (StyA) and urinary biomarkers in 10 varnish and 8 fiberglass reinforced plastic workers. Estimated geometric mean personal exposures to StyA were 2.96mg/m(3) in varnish workers and 15.7mg/m(3) in plastic workers. The corresponding levels of StyU, M1+M2, MA, PGA, MA+PGA, PHG and VP were 5.13microg/L, 0.111, 38.2, 22.7, 62.6, 0.978, and 3.97mg/g creatinine in varnish workers and 8.38microg/L, 0.303, 146, 83.4, 232, 2.85 and 3.97mg/g creatinine in plastic workers. Within-worker (sigma(wY)(2)) and between-worker (sigma(bY)(2)) variance components were estimated from the log-transformed data as were the corresponding fold ranges containing 95% of the respective lognormal distributions of daily levels ((w)R(0.95)) and subject-specific mean levels ((b)R(0.95)). Estimates of (w)R(0.95) (range: 4-26) were generally smaller than those of (b)R(0.95) (range: 5-790) for both environmental and biological markers; this indicates that exposures varied much more between workers than within workers in these groups. Since attenuation bias in an estimated exposure-response relationship increases with the variance ratio lambda=sigma(wY)(2)/sigma(bY)(2), we estimated values of lambda for all exposure measures in our study. Values of lambda were typically much less than one (median=0.220) and ranged from 0.089 for M1+M2 in plastic workers to 1.38 for PHG in varnish workers. Since values of lambda were 0.147 and 0.271 for StyA in varnish workers and plastic workers, respectively, compared to 0.178 and 0.210 for MA in the same groups, our results suggest that either

  4. Analyzing repeated measures semi-continuous data, with application to an alcohol dependence study.

    Science.gov (United States)

    Liu, Lei; Strawderman, Robert L; Johnson, Bankole A; O'Quigley, John M

    2016-02-01

    Two-part random effects models (Olsen and Schafer,(1) Tooze et al.(2)) have been applied to repeated measures of semi-continuous data, characterized by a mixture of a substantial proportion of zero values and a skewed distribution of positive values. In the original formulation of this model, the natural logarithm of the positive values is assumed to follow a normal distribution with a constant variance parameter. In this article, we review and consider three extensions of this model, allowing the positive values to follow (a) a generalized gamma distribution, (b) a log-skew-normal distribution, and (c) a normal distribution after the Box-Cox transformation. We allow for the possibility of heteroscedasticity. Maximum likelihood estimation is shown to be conveniently implemented in SAS Proc NLMIXED. The performance of the methods is compared through applications to daily drinking records in a secondary data analysis from a randomized controlled trial of topiramate for alcohol dependence treatment. We find that all three models provide a significantly better fit than the log-normal model, and there exists strong evidence for heteroscedasticity. We also compare the three models by the likelihood ratio tests for non-nested hypotheses (Vuong(3)). The results suggest that the generalized gamma distribution provides the best fit, though no statistically significant differences are found in pairwise model comparisons.

  5. Preliminary evaluation of a micro-based repeated measures testing system

    Science.gov (United States)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  6. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  7. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Directory of Open Access Journals (Sweden)

    Po-Shan Wang

    Full Text Available The aim of this study was to correlate magnetic resonance spectroscopy (MRS measurements, including that for the N-acetyl aspartate (NAA/creatine (Cr ratio in the vermis (denoted V-NAA, right cerebellar hemisphere (R-NAA, and left (L-NAA cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA score for patients with spinocerebellar ataxia (SCA types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  8. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Science.gov (United States)

    Wang, Po-Shan; Chen, Hung-Chieh; Wu, Hsiu-Mei; Lirng, Jiing-Feng; Wu, Yu-Te; Soong, Bing-Wen

    2012-01-01

    The aim of this study was to correlate magnetic resonance spectroscopy (MRS) measurements, including that for the N-acetyl aspartate (NAA)/creatine (Cr) ratio in the vermis (denoted V-NAA), right cerebellar hemisphere (R-NAA), and left (L-NAA) cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA) score for patients with spinocerebellar ataxia (SCA) types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score) in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  9. Added value measures in education show genetic as well as environmental influence.

    Science.gov (United States)

    Haworth, Claire M A; Asbury, Kathryn; Dale, Philip S; Plomin, Robert

    2011-02-02

    Does achievement independent of ability or previous attainment provide a purer measure of the added value of school? In a study of 4000 pairs of 12-year-old twins in the UK, we measured achievement with year-long teacher assessments as well as tests. Raw achievement shows moderate heritability (about 50%) and modest shared environmental influences (25%). Unexpectedly, we show that for indices of the added value of school, genetic influences remain moderate (around 50%), and the shared (school) environment is less important (about 12%). The pervasiveness of genetic influence in how and how much children learn is compatible with an active view of learning in which children create their own educational experiences in part on the basis of their genetic propensities.

  10. Repeatability of corticospinal and spinal measures during lengthening and shortening contractions in the human tibialis anterior muscle.

    Directory of Open Access Journals (Sweden)

    Jamie Tallent

    Full Text Available UNLABELLED: Elements of the human central nervous system (CNS constantly oscillate. In addition, there are also methodological factors and changes in muscle mechanics during dynamic muscle contractions that threaten the stability and consistency of transcranial magnetic stimulation (TMS and perpherial nerve stimulation (PNS measures. PURPOSE: To determine the repeatability of TMS and PNS measures during lengthening and shortening muscle actions in the intact human tibialis anterior. METHODS: On three consecutive days, 20 males performed lengthening and shortening muscle actions at 15, 25, 50 and 80% of maximal voluntary contraction (MVC. The amplitude of the Motor Evoked Potentials (MEPs produced by TMS was measured at rest and during muscle contraction at 90° of ankle joint position. MEPs were normalised to Mmax determined with PNS. The corticospinal silent period was recorded at 80% MVC. Hoffman reflex (H-reflex at 10% isometric and 25% shortening and lengthening MVCs, and V-waves during MVCs were also evoked on each of the three days. RESULTS: With the exception of MEPs evoked at 80% shortening MVC, all TMS-derived measures showed good reliability (ICC = 0.81-0.94 from days 2 to 3. Confidence intervals (CI, 95% were lower between days 2 and 3 when compared to days 1 and 2. MEPs significantly increased at rest from days 1 to 2 (P = 0.016 and days 1 to 3 (P = 0.046. The H-reflex during dynamic muscle contraction was reliable across the three days (ICC = 0.76-0.84. V-waves (shortening, ICC = 0.77, lengthening ICC = 0.54 and the H-reflex at 10% isometric MVC (ICC = 0.66 was generally less reliable over the three days. CONCLUSION: Although it is well known that measures of the intact human CNS exhibit moment-to-moment fluctuations, careful experimental arrangements make it possible to obtain consistent and repeatable measurements of corticospinal and spinal excitability in the actively lengthening and shortening human

  11. Accounting for uncertainty in volumes of seabed change measured with repeat multibeam sonar surveys

    Science.gov (United States)

    Schimel, Alexandre C. G.; Ierodiaconou, Daniel; Hulands, Lachlan; Kennedy, David M.

    2015-12-01

    Seafloors of unconsolidated sediment are highly dynamic features; eroding or accumulating under the action of tides, waves and currents. Assessing which areas of the seafloor experienced change and measuring the corresponding volumes involved provide insights into these important active sedimentation processes. Computing the difference between Digital Elevation Models (DEMs) obtained from repeat Multibeam Echosounders (MBES) surveys has become a common technique to identify these areas, but the uncertainty in these datasets considerably affects the estimation of the volumes displaced. The two main techniques used to take into account uncertainty in volume estimations are the limitation of calculations to areas experiencing a change in depth beyond a chosen threshold, and the computation of volumetric confidence intervals. However, these techniques are still in their infancy and, as a result, are often crude, seldom used or poorly understood. In this article, we explored a number of possible methodological advances to address this issue, including: (1) using the uncertainty information provided by the MBES data processing algorithm CUBE, (2) adapting fluvial geomorphology techniques for volume calculations using spatially variable thresholds and (3) volumetric histograms. The nearshore seabed off Warrnambool harbour - located in the highly energetic southwest Victorian coast, Australia - was used as a test site. Four consecutive MBES surveys were carried out over a four-months period. The difference between consecutive DEMs revealed an area near the beach experiencing large sediment transfers - mostly erosion - and an area of reef experiencing increasing deposition from the advance of a nearby sediment sheet. The volumes of sediment displaced in these two areas were calculated using the techniques described above, both traditionally and using the suggested improvements. We compared the results and discussed the applicability of the new methodological improvements

  12. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  13. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  14. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  15. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  16. A Correction for the Epsilon Approximate Test in Repeated Measures Designs with Two or More Independent Groups.

    Science.gov (United States)

    Lecoutre, Bruno

    1991-01-01

    The routine epsilon approximate test in repeated measures designs when the condition of circularity is unfulfilled uses an erroneous formula in the case of two or more groups. Because this may lead to underestimation of the deviation from circularity when the subject number is small, a correction is proposed. (Author/SLD)

  17. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients with...

  18. GSTM1 and APE1 genotypes affect arsenic-induced oxidative stress: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Quamruzzaman Quazi

    2007-12-01

    Full Text Available Abstract Background Chronic arsenic exposure is associated with an increased risk of skin, bladder and lung cancers. Generation of oxidative stress may contribute to arsenic carcinogenesis. Methods To investigate the association between arsenic exposure and oxidative stress, urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG was evaluated in a cohort of 97 women recruited from an arsenic-endemic region of Bangladesh in 2003. Arsenic exposure was measured in urine, toenails, and drinking water. Drinking water and urine samples were collected on three consecutive days. Susceptibility to oxidative stress was evaluated by genotyping relevant polymorphisms in glutathione-s transferase mu (GSTM1, human 8-oxoguanine glycosylase (hOGG1 and apurinic/apyrimidinic endonuclease (APE1 genes using the Taqman method. Data were analyzed using random effects Tobit regression to account for repeated measures and 8-OHdG values below the detection limit. Results A consistent negative effect for APE1 was observed across water, toenail and urinary arsenic models. APE1 148 glu/glu + asp/glu genotype was associated with a decrease in logged 8-OHdG of 0.40 (95%CI -0.73, -0.07 compared to APE1 148 asp/asp. An association between total urinary arsenic and 8-OHdG was observed among women with the GSTM1 null genotype but not in women with GSTM1 positive. Among women with GSTM1 null, a comparison of the second, third, and fourth quartiles of total urinary arsenic to the first quartile resulted in a 0.84 increase (95% CI 0.27, 1.42, a 0.98 increase (95% CI 033, 1.66 and a 0.85 increase (95% CI 0.27, 1.44 in logged 8-OHdG, respectively. No effects between 8-OHdG and toenail arsenic or drinking water arsenic were observed. Conclusion These results suggest the APE1 variant genotype decreases repair of 8-OHdG and that arsenic exposure is associated with oxidative stress in women who lack a functional GSTM1 detoxification enzyme.

  19. Pilot study: Assessing repeatability of the EcoWalk platform resistive pressure sensors to measure plantar pressure during barefoot standing

    Science.gov (United States)

    Zequera, Martha; Perdomo, Oscar; Wilches, Carlos; Vizcaya, Pedro

    2013-06-01

    Plantar pressure provides useful information to assess the feet's condition. These systems have emerged as popular tools in clinical environment. These systems present errors and no compensation information is presented by the manufacturer, leading to uncertainty in the measurements. Ten healthy subjects, 5 females and 5 males, were recruited. Lateral load distribution, antero-posterior load distribution, average pressure, contact area, and force were recorded. The aims of this study were to assess repeatability of the EcoWalk system and identify the range of pressure values observed in the normal foot. The coefficient of repeatability was less than 4% for all parameters considered.

  20. Extended fluctuation theorems for repeated measurements and feedback within Hamiltonian framework

    Energy Technology Data Exchange (ETDEWEB)

    Lahiri, Sourabh, E-mail: sourabhlahiri@gmail.com [Laboratoire de Physico-Chimie Théorique, ESPCI, 10 rue Vauquelin, F-75231 Paris (France); Jayannavar, A.M. [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005 (India)

    2016-04-29

    We derive the extended fluctuation theorems in presence of multiple measurements and feedback, when the system is governed by Hamiltonian dynamics. We use only the forward phase space trajectories in the derivation. However, to obtain an expression for the efficacy parameter, we must necessarily use the notion of reverse trajectory. Our results show that the correction term appearing in the exponent of the extended fluctuation theorems is non-unique, whereas the physical meaning of the efficacy parameter is unique. - Highlights: • Extended Fluctuation Theorems under multiple measurements and feedback have been derived using Hamiltonian dynamics. • We prove the theorems without using the notion of reverse trajectory. • We show that the correction terms are not unique. • The efficacy parameter is shown to have a unique physical meaning.

  1. Repeatability of measurements: Non-Hermitian observables and quantum Coriolis force

    Science.gov (United States)

    Gardas, Bartłomiej; Deffner, Sebastian; Saxena, Avadh

    2016-08-01

    A noncommuting measurement transfers, via the apparatus, information encoded in a system's state to the external "observer." Classical measurements determine properties of physical objects. In the quantum realm, the very same notion restricts the recording process to orthogonal states as only those are distinguishable by measurements. Therefore, even a possibility to describe physical reality by means of non-Hermitian operators should volens nolens be excluded as their eigenstates are not orthogonal. Here, we show that non-Hermitian operators with real spectra can be treated within the standard framework of quantum mechanics. Furthermore, we propose a quantum canonical transformation that maps Hermitian systems onto non-Hermitian ones. Similar to classical inertial forces this map is accompanied by an energetic cost, pinning the system on the unitary path.

  2. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y.; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%) however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  3. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    Directory of Open Access Journals (Sweden)

    Semra Tiryaki Demir

    2014-08-01

    Full Text Available Objectives: Comparison of central corneal thickness (CCT measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG, 41 patients with ocular hypertension (OHT, and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000 were used for measurement of CCT. ANOVA (Turkey test was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p0.05. CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001. Repeatability of ultrasonic pachymetry for same observer was (ICC value 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7

  4. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah

    2016-01-01

    Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement...... of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume...... and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema....

  5. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  6. Effects of repeatability measures on results of fMRI sICA: a study on simulated and real resting-state effects.

    Science.gov (United States)

    Remes, Jukka J; Starck, Tuomo; Nikkinen, Juha; Ollila, Esa; Beckmann, Christian F; Tervonen, Osmo; Kiviniemi, Vesa; Silven, Olli

    2011-05-15

    Spatial independent components analysis (sICA) has become a widely applied data-driven method for fMRI data, especially for resting-state studies. These sICA approaches are often based on iterative estimation algorithms and there are concerns about accuracy due to noise. Repeatability measures such as ICASSO, RAICAR and ARABICA have been introduced as remedies but information on their effects on estimates is limited. The contribution of this study was to provide more of such information and test if the repeatability analyses are necessary. We compared FastICA-based ordinary and repeatability approaches concerning mixing vector estimates. Comparisons included original FastICA, FSL4 Melodic FastICA and original and modified ICASSO. The effects of bootstrapping and convergence threshold were evaluated. The results show that there is only moderate improvement due to repeatability measures and only in the bootstrapping case. Bootstrapping attenuated power from time courses of resting-state network related ICs at frequencies higher than 0.1 Hz and made subsets of low frequency oscillations more emphasized IC-wise. The convergence threshold did not have a significant role concerning the accuracy of estimates. The performance results suggest that repeatability measures or strict converge criteria might not be needed in sICA analyses of fMRI data. Consequently, the results in existing sICA fMRI literature are probably valid in this sense. A decreased accuracy of original bootstrapping ICASSO was observed and corrected by using centrotype mixing estimates but the results warrant for thorough evaluations of data-driven methods in general. Also, given the fMRI-specific considerations, further development of sICA methods is strongly encouraged. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    Directory of Open Access Journals (Sweden)

    Maria Magdalena Dresler

    2017-06-01

    Full Text Available Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.

  8. The use of portable NIRS to measure muscle oxygenation and haemodynamics during a repeated sprint running test.

    Science.gov (United States)

    Jones, Ben; Hesford, Catherine M; Cooper, Chris E

    2013-01-01

    Portable near-infrared spectroscopy (NIRS) devices were originally developed for use in exercise and sports science by Britton Chance in the 1990s (the RunMan and microRunman series). However, only recently with the development of more robust, and wireless systems, has the routine use in elite sport become possible. As with the medical use of NIRS, finding applications of the technology that are relevant to practitioners is the key issue. One option is to use NIRS to track exercise training-induced adaptations in muscle. Portable NIRS devices enable monitoring during the normal 'field' routine uses to assess fitness, such as repeat sprint shuttle tests. Knowledge about the acute physiological responses to these specific tests has practical applications within team sport training prescription, where development of both central and peripheral determinants of high-intensity intermittent exercise needs to be considered. The purpose of this study was to observe NIRS-detected parameters during a repeat sprint test. We used the PortaMon, a two wavelength spatially resolved NIR spectrometer manufactured by Artinis Inc., to assess NIR changes in the gastrocnemius muscle of both the left and right leg during high-intensity running. Six university standard rugby players were assessed (age 20 ± 1.5 years; height 183 ± 1.0 cm; weight 89.4 ± 5.8 kg; body fat 12.2 ± 3.0 %); the subjects completed nine repeated shuttle runs, which incorporated forward, backward and change of direction movements. Individual sprint time, total time to complete test, blood lactate response (BL), heart rate values (HR) and haemoglobin variables (ΔHHb, ΔtHb, ΔHbO2 and ΔTSI%) were measured. Total time to complete the test was 260 ± 20 s, final blood lactate was 14.3 ± 2.8 mM, and maximal HR 182 ± 5 bpm. NIRS variables displayed no differences between right and left legs. During the test, the group-averaged data showed a clear decrease in HbO2 (max. decrease 11.41 ± 4.95 μM), increase in HHb

  9. A method to construct a points system to predict cardiovascular disease considering repeated measures of risk factors

    Science.gov (United States)

    Carbayo-Herencia, Julio Antonio; Vigo, Maria Isabel; Gil-Guillén, Vicente Francisco

    2016-01-01

    Current predictive models for cardiovascular disease based on points systems use the baseline situation of the risk factors as independent variables. These models do not take into account the variability of the risk factors over time. Predictive models for other types of disease also exist that do consider the temporal variability of a single biological marker in addition to the baseline variables. However, due to their complexity these other models are not used in daily clinical practice. Bearing in mind the clinical relevance of these issues and that cardiovascular diseases are the leading cause of death worldwide we show the properties and viability of a new methodological alternative for constructing cardiovascular risk scores to make predictions of cardiovascular disease with repeated measures of the risk factors and retaining the simplicity of the points systems so often used in clinical practice (construction, statistical validation by simulation and explanation of potential utilization). We have also applied the system clinically upon a set of simulated data solely to help readers understand the procedure constructed. PMID:26893963

  10. Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

    Directory of Open Access Journals (Sweden)

    Raza Abid

    2010-04-01

    Full Text Available Abstract Background Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden, is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers. Methods Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study. Results The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb, although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p Conclusions The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.

  11. Reliability of plasma lipopolysaccharide-binding protein (LBP) from repeated measures in healthy adults.

    Science.gov (United States)

    Citronberg, Jessica S; Wilkens, Lynne R; Lim, Unhee; Hullar, Meredith A J; White, Emily; Newcomb, Polly A; Le Marchand, Loïc; Lampe, Johanna W

    2016-09-01

    Plasma lipopolysaccharide-binding protein (LBP), a measure of internal exposure to bacterial lipopolysaccharide, has been associated with several chronic conditions and may be a marker of chronic inflammation; however, no studies have examined the reliability of this biomarker in a healthy population. We examined the temporal reliability of LBP measured in archived samples from participants in two studies. In Study one, 60 healthy participants had blood drawn at two time points: baseline and follow-up (either three, six, or nine months). In Study two, 24 individuals had blood drawn three to four times over a seven-month period. We measured LBP in archived plasma by ELISA. Test-retest reliability was estimated by calculating the intraclass correlation coefficient (ICC). Plasma LBP concentrations showed moderate reliability in Study one (ICC 0.60, 95 % CI 0.43-0.75) and Study two (ICC 0.46, 95 % CI 0.26-0.69). Restricting the follow-up period improved reliability. In Study one, the reliability of LBP over a three-month period was 0.68 (95 % CI: 0.41-0.87). In Study two, the ICC of samples taken ≤seven days apart was 0.61 (95 % CI 0.29-0.86). Plasma LBP concentrations demonstrated moderate test-retest reliability in healthy individuals with reliability improving over a shorter follow-up period.

  12. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration.

    Science.gov (United States)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie; Sagoo, Mandeep S; Tufail, Adnan; Balaggan, Kamaljit S; Patel, Praveen J

    2017-05-01

    The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). A prospective study consisting of patients with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS macular subfields. Repeatability was calculated according to methods described by Bland and Altman. 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm). The repeatability this subfield, expressed as a percentage of the mean central macular subfield thickness, was 23.2%. The percentage repeatability of the other macular subfields ranged from 13.2% to 28.7%. The intrasession coefficient of repeatability of choroidal thickness of the central macular subfield was 57.2 μm with a mean choroidal thickness (±SD) of 181 μm (±15.8 μm). This study suggests that a change >23.2% of retinal thickness and 57.2 μm choroidal thickness in the central macular subfield is required to distinguish true clinical change from measurement variability when using the DRI OCT-1 device to manage patients with nAMD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    OpenAIRE

    Semra Tiryaki Demir; Mahmut Odabaşı; Mehmet Ersin Oba; Ayşe Burcu Dirim; Efe Can; Orhan Kara

    2014-01-01

    Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) ...

  14. Repeated Microsphere Delivery for Serial Measurement of Regional Blood Perfusion in the Chronically Instrumented, Conscious Canine

    Science.gov (United States)

    Bartoli, Carlo R.; Okabe, Kazunori; Akiyama, Ichiro; Coull, Brent; Godleski, John J.

    2008-01-01

    INTRODUCTION For chronic, repeated hemodynamic studies in conscious dogs, we designed and tested a chronically instrumented canine, microsphere delivery model. The goals of this study were to investigate the accuracy of repeated estimations of blood perfusion using fluorescent-labeled microspheres and to develop and validate a chronic preparation that permits consecutive estimations in the same conscious animal over an extended protocol. METHODS Via thoracotomy, 9 dogs were instrumented with left atrial appendage and aortic vascular access catheters connected to subcutaneous vascular access ports (VAPs). Four animals received 7 serial injections of 1.6 million 15μm microspheres (total: 11.2 million), and five animals received 8 serial injections of 2.25 million microspheres (total: 18 million) over the course of 11 or 18 weeks. RESULTS All catheters have remained bidirectionally patent during protocol for 14.9±0.8 (Mean±SEM) weeks. Sphere accumulation did not significantly alter global myocardial (p=0.69, p=0.25), renal (p=0.92, p=0.12), hepatic (p=0.84, p=0.32), or splenic (p=0.33, p=0.70) blood perfusion in either set of animals. CONCLUSIONS Catheters remained bidirectionally patent for months, did not interfere with the hemodynamic responses of the preparation, and allowed repeat percutaneous injection of microspheres and withdrawal of reference arterial blood from within conscious canines. Eight serial injections totaling 18 million microspheres over 18 weeks did not alter regional myocardial, hepatic, renal, or splenic blood flow. This dependable, chronic, percutaneous arterial access preparation provides a means for examining acute and long-term effects of pathophysiological, pharmaceutical, and environmental influences on regional arterial blood perfusion in conscious, large animals. PMID:17632127

  15. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  16. Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy

    Institute of Scientific and Technical Information of China (English)

    LI De-jiao; WANG Ning-li; CHEN Shu; LI Shu-ning; MU Da-peng; WANG Tao

    2009-01-01

    Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia. Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM).Methods A fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator.Results On a scale of 1 mm, the greatest indicating error was 40 μm; the mean largest indicating error of 1 mm scale from the 10 images was (26±14) μm; on a scale of 11 mm, the greatest indicating error was 70 μo; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 μm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were-0.41 mm to 0.48 mm and -0.59 mm to 0.58 ram, respectively.Conclusion The full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct

  17. The wildgeographer avatar shows how to measure soil erosion rates by means of a rainfall simulator

    Science.gov (United States)

    Cerdà, Artemi; González Pelayo, Óscar; Pereira, Paulo; Novara, Agata; Iserloh, Thomas; Prosdocimi, Massimo

    2015-04-01

    This contribution to the immersed worlds wish to develop the avatar that will teach the students and other scientists how to develop measurements of soil erosion, surface runoff and wetting fronts by means of simulated rainfall experiments. Rainfall simulation is a well established and knows methodology to measure the soil erosion rates and soil hydrology under controlled conditions (Cerdà 1998a; Cerdà, 1998b; Cerdà and Jurgensen, 2011; Dunkerley, 2012; Iserloh et al., 2012; Iserloh et al., 2013; Ziadat and Taimeh, 2013; Butzen et al., 2014). However, is a method that requires a long training and expertise to avoid mismanagement and mistaken. To use and avatar can help in the teaching of the technique and the dissemination of the findings. This contribution will show to other avatars how to develop an experiment with simulated rainfall and will help to take the right decision in the design of the experiments. Following the main parts of the experiments and measurements the Wildgeographer avatar must develop: 1. Determine the objectives and decide which rainfall intensity and distribution, and which plot size to be used. Choose between a laboratory or a field rainfall simulation. 2. Design of the rainfall simulator to achieve the objectives: type of rainfall simulator (sprayer or drop former) and calibrate. 3. The experiments are carried out. 4. The results are show. Acknowledgements To the "Ministerio de Economía and Competitividad" of Spanish Government for finance the POSTFIRE project (CGL2013- 47862-C2-1-R). The research projects GL2008-02879/BTE, LEDDRA 243857 and PREVENTING AND REMEDIATING DEGRADATION OF SOILS IN EUROPE THROUGH LAND CARE (RECARE)FP7-ENV-2013- supported this research. References Butzen, V., Seeger, M., Wirtz, S., Huemann, M., Mueller, C., Casper, M., Ries, J. B. 2014. Quantification of Hortonian overland flow generation and soil erosion in a Central European low mountain range using rainfall experiments. Catena, 113, 202-212. Cerdà, A

  18. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    DEFF Research Database (Denmark)

    Miles, James Edward; Jensen, Bente Rona; Kirpensteijn, Jolle

    2013-01-01

    Objective-To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind limbs. An...... and applied criteria. The TT-TG offset distance has potential as an objective assessment of alignment of the distal portion of the quadriceps mechanism; its use as an aid in case selection for corrective femoral osteotomy among dogs with medial patellar luxation warrants investigation....

  19. Repeated measures of inflammation and oxidative stress biomarkers in preeclamptic and normotensive pregnancies.

    Science.gov (United States)

    Ferguson, Kelly K; Meeker, John D; McElrath, Thomas F; Mukherjee, Bhramar; Cantonwine, David E

    2017-05-01

    tumor necrosis factor-α were consistently elevated at all 4 of the study visits (hazard ratios, 1.49-1.63; Pinflammation and oxidative stress in preeclamptic compared with normotensive pregnancies. Within these groups, inflammation and oxidative stress biomarkers show different patterns across gestation, beginning as early as 10 weeks. The start of the second trimester appears to be a particularly important time point for the measurement of these biomarkers. Although biomarkers alone do not appear to be useful in the prediction of preeclampsia, these data are useful in understanding the maternal inflammatory profile in pregnancy before the development of the disease and may be used to further develop an understanding of potentially preventative measures. Published by Elsevier Inc.

  20. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  1. Multiple disadvantages among older citizens: what a multidimensional measure of poverty can show.

    Science.gov (United States)

    Callander, Emily J; Schofield, Deborah J; Shrestha, Rupendra N

    2012-01-01

    Using the newly created Freedom Poverty Measure, a multidimensional measure of poverty, it can be seen that there were 534,700 individuals who were in freedom poverty, who had either poor health or poor education in addition to having low incomes. This multidimensional disadvantage would not normally be captured by single measures of poverty, such as income poverty measures. Men were significantly less likely to be in freedom poverty than women (OR = 0.63, 95% CI: 0.54-0.74, p poverty increased with age, with those older than 85 being 2.3 times more likely to be in freedom poverty than those aged 65 to 69 years (95% CI: 1.73-3.11, p < .0001). Policy responses to address the marginalization of disadvantaged older people should take a multidisciplinary approach, addressing health inequalities in particular, not just low income.

  2. A Description of Quasar Variability Measured Using Repeated SDSS and POSS Imaging

    CERN Document Server

    MacLeod, Chelsea L; Sesar, Branimir; de Vries, Wim; Kochanek, Christopher S; Kelly, Brandon C; Becker, Andrew C; Lupton, Robert H; Hall, Patrick B; Richards, Gordon T; Anderson, Scott F; Schneider, Donald P

    2011-01-01

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 34,727 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along stripe 82 (S82), whereas the remaining ~25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000A to 6000A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic time scale and an asymptotic variabilit...

  3. Estimation of spatial patterns of urban air pollution over a 4-week period from repeated 5-min measurements

    Science.gov (United States)

    Gillespie, Jonathan; Masey, Nicola; Heal, Mathew R.; Hamilton, Scott; Beverland, Iain J.

    2017-02-01

    Determination of intra-urban spatial variations in air pollutant concentrations for exposure assessment requires substantial time and monitoring equipment. The objective of this study was to establish if short-duration measurements of air pollutants can be used to estimate longer-term pollutant concentrations. We compared 5-min measurements of black carbon (BC) and particle number (PN) concentrations made once per week on 5 occasions, with 4 consecutive 1-week average nitrogen dioxide (NO2) concentrations at 18 locations at a range of distances from busy roads in Glasgow, UK. 5-min BC and PN measurements (averaged over the two 5-min periods at the start and end of a week) explained 40-80%, and 7-64% respectively, of spatial variation in the intervening 1-week NO2 concentrations for individual weeks. Adjustment for variations in background concentrations increased the percentage of explained variation in the bivariate relationship between the full set of NO2 and BC measurements over the 4-week period from 28% to 50% prior to averaging of repeat measurements. The averages of five 5-min BC and PN measurements made over 5 weeks explained 75% and 33% respectively of the variation in average 1-week NO2 concentrations over the same period. The relatively high explained variation observed between BC and NO2 measured on different time scales suggests that, with appropriate steps to correct or average out temporal variations, repeated short-term measurements can be used to provide useful information on longer-term spatial patterns for these traffic-related pollutants.

  4. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus.

    Science.gov (United States)

    Jager-Wittenaar, H; Dijkstra, P U; Vissink, A; van Oort, R P; Roodenburg, J L N

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this study was to analyse the variation in mouth-opening measurements in patients treated for head and neck cancer, with and without trismus. Maximal mouth opening was measured in 120 patients in two sessions of three repeated measurements by one observer. To analyse the influence of interobserver variation on mouth-opening measurements a subgroup of 30 patients was measured by a second observer. The standard deviation of the six measurements per patient was used as the variation in measurements of maximal mouth opening. No significant difference was found in maximal mouth opening in patients with (n=33) or without (n=87) trismus. The interobserver intraclass correlation coefficient (ICC) was 0.98. Intraobserver ICC and intersession ICC reliabilities both were 0.99. The variation in the mean values of the three measurements was only slightly smaller than the variation of the single measurements. Variation in maximal mouth opening in patients with trismus does not differ from variation in maximal mouth opening in patients without trismus. Interobserver variation is limited.

  5. A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    MacLeod, Chelsea L.; Ivezic, Zeljko; Becker, Andrew C.; Anderson, Scott F. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Sesar, Branimir [Division of Physics, Mathematics and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); De Vries, Wim [Department of Physics, University of California, One Shields Ave, Davis, CA 95616 (United States); Kochanek, Christopher S. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Kelly, Brandon C. [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Lupton, Robert H. [Department of Astrophysical Sciences, Princeton University, Princeton, New Jersey 08544 (United States); Hall, Patrick B. [Department of Physics and Astronomy, York University, Toronto, ON M3J 1P3 (Canada); Richards, Gordon T. [Department of Physics, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Schneider, Donald P. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States)

    2012-07-10

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining {approx}25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 A to 6000 A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of {approx}5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

  6. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T1-weighted images (3D-T1WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  7. Repeatability of Cone Spacing Measures in Eyes With Inherited Retinal Degenerations

    National Research Council Canada - National Science Library

    Zayit-Soudry, Shiri; Sippl-Swezey, Nicolas; Porco, Travis C; Lynch, Stephanie K; Syed, Reema; Ratnam, Kavitha; Menghini, Moreno; Roorda, Austin J; Duncan, Jacque L

    2015-01-01

    ...)-derived cone spacing measures in eyes with inherited retinal degenerations (IRD) and in normal eyes. Twenty IRD patients and 10 visually normal subjects underwent AOSLO imaging at two visits separated by no more than 1 month...

  8. Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries.

    Science.gov (United States)

    Vuong, Vivian S; Moisseiev, Elad; Cunefare, David; Farsiu, Sina; Moshiri, Ala; Yiu, Glenn

    2016-09-01

    To assess the reliability of manual choroidal thickness measurements by comparing different posterior boundary definitions of the choroidal-scleral junction on enhanced depth imaging optical coherence tomography (EDI-OCT). Reliability analysis. Two graders marked the choroidal-scleral junction with segmentation software using different posterior boundaries: (1) the outer border of the choroidal vessel lumen, (2) the outer border of the choroid stroma, and (3) the inner border of the sclera, to measure the vascular choroidal thickness (VCT), stromal choroidal thickness (SCT), and total choroidal thickness (TCT), respectively. Measurements were taken at 0.5-mm intervals from 1.5 mm nasal to 1.5 mm temporal to the fovea, and averaged continuously across the central 3 mm of the macula. Intraclass correlation coefficient (ICC) and coefficient of reliability (CR) were compared to assess intergrader and intragrader reliability. Choroidal thickness measurements varied significantly with different posterior boundaries (P choroidal-scleral junction visibility was Choroidal thickness measurements are more reproducible when measured to the border of the choroid stroma (SCT) than the vascular lumen (VCT) or sclera (TCT). Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Direct mass measurements of Cd isotopes show strong shell gap at N=82

    CERN Document Server

    Knöbel, R; Bosch, F; Boutin, D; Chen, L; Dimopoulou, C; Dolinskii, A; Franczak, B; Franzke, B; Geissel, H; Hausmann, M; Kozhuharov, C; Kurcewicz, J; Litvinova, S A; Martínez-Pinedo, G; Matoš, M; Mazzocco, M; Münzenberg, G; Nakajima, S; Nociforo, C; Nolden, F; Ohtsubo, T; Ozawa, A; Patyk, Z; Plaß, W R; Scheidenberger, C; Stadlmann, J; Steck, M; Sun, B; Suzuki, T; Walker, P; Weick, H; Wu, M -R; Winkler, M; Yamaguchi, T

    2015-01-01

    A $^{238}$U projectile beam was used to create cadmium isotopes via abrasion-fission at 410 MeV/u in a beryllium target at the entrance of the in-flight separator FRS at GSI. The fission fragments were separated with the FRS and injected into the isochronous storage ring ESR for mass measurements. The Isochronous Mass Spectrometry (IMS) was performed under two different experimental conditions, with and without B$\\rho$-tagging at the dispersive central focal plane of the FRS. In the experiment with B$\\rho$-tagging the magnetic rigidity of the injected fragments was determined by an accuracy of $2\\times 10^{-4}$. A new method of data analysis, using a correlation matrix for the combined data set from both experiments, has provided mass values for 25 different isotopes for the first time. The high selectivity and sensitivity of the experiment and analysis has given access even to rare isotopes detected with a few atoms per week. In this letter we present for the $^{129,130,131}$Cd isotopes mass values directly ...

  10. Optical volume and mass measurements show that mammalian cells swell during mitosis.

    Science.gov (United States)

    Zlotek-Zlotkiewicz, Ewa; Monnier, Sylvain; Cappello, Giovanni; Le Berre, Mael; Piel, Matthieu

    2015-11-23

    The extent, mechanism, and function of cell volume changes during specific cellular events, such as cell migration and cell division, have been poorly studied, mostly because of a lack of adequate techniques. Here we unambiguously report that a large range of mammalian cell types display a significant increase in volume during mitosis (up to 30%). We further show that this increase in volume is tightly linked to the mitotic state of the cell and not to its spread or rounded shape and is independent of the presence of an intact actomyosin cortex. Importantly, this volume increase is not accompanied by an increase in dry mass and thus corresponds to a decrease in cell density. This mitotic swelling might have important consequences for mitotic progression: it might contribute to produce strong pushing forces, allowing mitotic cells to round up; it might also, by lowering cytoplasmic density, contribute to the large change of physicochemical properties observed in mitotic cells.

  11. Snow chemistry measurements on James Ross Island (Antarctic Peninsula) showing sea-salt aerosol modifications

    Energy Technology Data Exchange (ETDEWEB)

    Aristarain, A.J. [Instituto Antartico Argentino (Argentina). Lab. de Estratigrafia Glaciar y Geoquimica de la Nieve; Consejo Nacional de Investigaciones Cientificas y Tecnicas, Mendoza (Argentina); Delmas, R.J. [Laboratoire de Glaciologie et Geophysique de l' Environnement du CNRS, St Martin d' Heres (France)

    2002-07-01

    The fractionation of atmospheric sea-salt has been investigated by glaciochemical analysis of the sea-salt deposited on the snow covering the small ice cap of James Ross Island, Antarctic Peninsula, at an elevation of 1640m. The data show that, generally, but not always, the sea-salt deposited at this location most likely originates directly from seawater, as is the case at lower latitudes. It is found that the original chemical composition of the sea-salt aerosol is significantly modified, in particular by the reaction of sea-salt particles in the atmosphere with acid species. A ternary diagram (sodium, chloride, sulfate) is used to enlighten the involved modification processes. The study points out the frequent formation of HCl in the regional atmosphere. (Author)

  12. Mediation of the Relationship between Maternal Phthalate Exposure and Preterm Birth by Oxidative Stress with Repeated Measurements across Pregnancy.

    Science.gov (United States)

    Ferguson, Kelly K; Chen, Yin-Hsiu; VanderWeele, Tyler J; McElrath, Thomas F; Meeker, John D; Mukherjee, Bhramar

    2017-03-01

    Mediation analysis is useful for understanding mechanisms and has been used minimally in the study of the environment and disease. We examined mediation of the association between phthalate exposure during pregnancy and preterm birth by oxidative stress. This nested case-control study of preterm birth (n = 130 cases, 352 controls) included women who delivered in Boston, Massachusestts, from 2006 through 2008. Phthalate metabolites and 8-isoprostane, an oxidative stress biomarker, were measured in urine from three visits in pregnancy. We applied four counterfactual mediation methods: method 1, utilizing exposure and mediator averages; method 2, using averages but allowing for an exposure-mediator interaction; method 3, incorporating longitudinal measurements of the exposure and mediator; and method 4, using longitudinal measurements and allowing for an exposure-mediator interaction. We observed mediation of the associations between phthalate metabolites and all preterm birth by 8-isoprostane, with the greatest estimated proportion mediated observed for spontaneous preterm births specifically. Fully utilizing repeated measures of the exposure and mediator improved precision of indirect (i.e., mediated) effect estimates, and including an exposure-mediator interaction increased the estimated proportion mediated. For example, for mono(2-ethyl-carboxy-propyl) phthalate (MECPP), a metabolite of di(2-ethylhexyl) phthalate (DEHP), the percent of the total effect mediated by 8-isoprostane increased from 47% to 60% with inclusion of an exposure-mediator interaction term, in reference to a total adjusted odds ratio of 1.67 or 1.48, respectively. This demonstrates mediation of the phthalate-preterm birth relationship by oxidative stress, and the utility of complex regression models in capturing mediated associations when repeated measures of exposure and mediator are available and an exposure-mediator interaction may exist. Citation: Ferguson KK, Chen YH, VanderWeele TJ, Mc

  13. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Wheeler, Kevin; Hensley, Scott; Lou, Yunling

    2004-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeatpass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV or minimally piloted vehicle (MPV).

  14. Repeated measurements of P retention in ponies fed rations with various Ca:P ratios

    NARCIS (Netherlands)

    van Doorn, D A; Schaafstra, F J W C; Wouterse, H; Everts, H; Estepa, J C; Aguilera-Tejero, E; Beynen, A C

    2014-01-01

    This study addresses the question of whether feeding rations rich in P for a period of up to 42 d induces a positive P balance in adult ponies. Biochemical bone markers and parathyroid hormone (PTH; intact as well as whole PTH) were measured to obtain clues as to the effect of P loading on bone meta

  15. Repeated measures of urinary oxidative stress biomarkers during pregnancy and preterm birth.

    Science.gov (United States)

    Ferguson, Kelly K; McElrath, Thomas F; Chen, Yin-Hsiu; Loch-Caruso, Rita; Mukherjee, Bhramar; Meeker, John D

    2015-02-01

    The purpose of this study was to investigate oxidative stress as a mechanism of preterm birth in human subjects; we examined associations between urinary biomarkers of oxidative stress that were measured at multiple time points during pregnancy and preterm birth. This nested case-control study included 130 mothers who delivered preterm and 352 mothers who delivered term who were originally recruited as part of an ongoing prospective birth cohort at Brigham and Women's Hospital. Two biomarkers that included 8-hydroxydeoxyguanosine (8-OHdG) and 8-isoprostane were measured in urine samples that were collected at up to 4 time points (median 10, 18, 26, and 35 weeks) during gestation. Urinary concentrations of 8-isoprostane and 8-OHdG decreased and increased, respectively, as pregnancy progressed. Average levels of 8-isoprostane across pregnancy were associated with increased odds of spontaneous preterm birth (adjusted odds ratio, 6.25; 95% confidence interval, 2.86-13.7), and associations were strongest with levels measured later in pregnancy. Average levels of 8-OHdG were protective against overall preterm birth (adjusted odds ratio, 0.19; 95% confidence interval, 0.10-0.34), and there were no apparent differences in the protective effect in cases of spontaneous preterm birth compared with cases of placental origin. Odds ratios for overall preterm birth were more protective in association with urinary 8-OHdG concentrations that were measured early in pregnancy. Maternal oxidative stress may be an important contributor to preterm birth, regardless of subtype and timing of exposure during pregnancy. The 2 biomarkers that were measured in the present study had opposite associations with preterm birth; an improved understanding of what each represents may help to identify more precisely important mechanisms in the pathway to preterm birth. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig.

  17. Composite tube and plate manufacturing repeatability as determined by precision measurements of thermal strain

    Science.gov (United States)

    Riddle, Lenn A.; Tucker, James R.; Bluth, A. Marcel

    2013-09-01

    Composite materials often carry the reputation of demonstrating high variability in critical material properties. The JWST telescope metering structure is fabricated of several thousand separate composite piece parts. The stringent dimensional stability requirements on the metering structure require the critical thermal strain response of every composite piece be verified either at the billet or piece part level. JWST is a unique composite space structure in that it has required the manufacturing of several hundred composite billets that cover many lots of prepreg and many years of fabrication. The flight billet thermal expansion acceptance criteria limits the coefficient of thermal expansion (CTE) to a tolerance ranging between +/-0.014 ppm/K to +/-0.04 ppm/K around a prescribed nominal when measured from 293 K down to 40 K. The different tolerance values represent different material forms including flat plates and different tube cross-section dimensions. A precision measurement facility was developed that could measure at the required accuracy and at a pace that supported the composite part fabrication rate. The test method and facility is discussed and the results of a statistical process analysis of the flight composite billets are surveyed.

  18. Global sensitivity analysis for repeated measures studies with informative drop-out: A semi-parametric approach.

    Science.gov (United States)

    Scharfstein, Daniel; McDermott, Aidan; Díaz, Iván; Carone, Marco; Lunardon, Nicola; Turkoz, Ibrahim

    2017-05-23

    In practice, both testable and untestable assumptions are generally required to draw inference about the mean outcome measured at the final scheduled visit in a repeated measures study with drop-out. Scharfstein et al. (2014) proposed a sensitivity analysis methodology to determine the robustness of conclusions within a class of untestable assumptions. In their approach, the untestable and testable assumptions were guaranteed to be compatible; their testable assumptions were based on a fully parametric model for the distribution of the observable data. While convenient, these parametric assumptions have proven especially restrictive in empirical research. Here, we relax their distributional assumptions and provide a more flexible, semi-parametric approach. We illustrate our proposal in the context of a randomized trial for evaluating a treatment of schizoaffective disorder. © 2017, The International Biometric Society.

  19. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  20. Assessment of individual agreements with repeated measurements based on generalized confidence intervals.

    Science.gov (United States)

    Quiroz, Jorge; Burdick, Richard K

    2009-01-01

    Individual agreement between two measurement systems is determined using the total deviation index (TDI) or the coverage probability (CP) criteria as proposed by Lin (2000) and Lin et al. (2002). We used a variance component model as proposed by Choudhary (2007). Using the bootstrap approach, Choudhary (2007), and generalized confidence intervals, we construct bounds on TDI and CP. A simulation study was conducted to assess whether the bounds maintain the stated type I error probability of the test. We also present a computational example to demonstrate the statistical methods described in the paper.

  1. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  2. C-reactive Protein: Repeated Measurements will Improve Dialysis Patient Care.

    Science.gov (United States)

    Cobo, Gabriela; Qureshi, Abdul Rashid; Lindholm, Bengt; Stenvinkel, Peter

    2016-01-01

    Systemic inflammation is a common feature in the uremic phenotype and associates with poor outcomes. The awareness regarding the importance of inflammation assessment in chronic kidney disease (CKD) patients has risen in recent years, and despite the development of novel biomarkers, C-reactive protein (CRP) is still the most measured inflammatory parameter. Notwithstanding, the possible weak points of CRP determination, this biomarker has demonstrated being useful both for guidance in clinical practice and for risk estimation. In addition, regular determination of CRP among dialysis patients has been associated with better outcomes in different dialysis facilities. Because persistent inflammation may be a silent reflection of various pathophysiologic alterations in CKD, it is crucial that inflammatory markers are regularly monitored and therapeutic attempts be made to target this inflammation.

  3. Repeated heart rate measurement and cardiovascular outcomes in left ventricular systolic dysfunction.

    Science.gov (United States)

    Hamill, Victoria; Ford, Ian; Fox, Kim; Böhm, Michael; Borer, Jeffrey S; Ferrari, Roberto; Komajda, Michel; Steg, Philippe Gabriel; Tavazzi, Luigi; Tendera, Michal; Swedberg, Karl

    2015-10-01

    Elevated resting heart rate is associated with increased cardiovascular risk, particularly in patients with left ventricular systolic dysfunction. Heart rate is not monitored routinely in these patients. We hypothesized that routine monitoring of heart rate would increase its prognostic value in patients with left ventricular systolic dysfunction. We analyzed the relationship between heart rate measurements and a range of adverse cardiovascular outcomes, including hospitalization for worsening heart failure, in the pooled placebo-treated patients from the morBidity-mortality EvAlUaTion of the If inhibitor ivabradine in patients with coronary disease and left ventricULar dysfunction (BEAUTIFUL) trial and Systolic Heart failure treatment with the If inhibitor ivabradine (SHIFT) Trial, using standard and time-varying covariate Cox proportional hazards models. By adjusting for other prognostic factors, models were fitted for baseline heart rate alone or for time-updated heart rate (latest heart rate) alone or corrected for baseline heart rate or for immediate previous time-updated heart rate. Baseline heart rate was strongly associated with all outcomes apart from hospitalization for myocardial infarction. Time-updated heart rate increased the strengths of associations for all outcomes. Adjustment for baseline heart rate or immediate previous time-updated heart rate modestly reduced the prognostic importance of time-updated heart rate. For hospitalization for worsening heart failure, each 5 beats/min increase in baseline heart rate and time-updated heart rate was associated with a 15% (95% confidence interval, 12-18) and 22% (confidence interval, 19-40) increase in risk, respectively. Even after correction, the prognostic value of time-updated heart rate remained greater. In patients with left ventricular systolic dysfunction, time-updated heart rate is more strongly related with adverse cardiovascular outcomes than baseline heart rate. Heart rate should be measured to

  4. Psychological impact and recovery after involvement in a patient safety incident: a repeated measures analysis

    Science.gov (United States)

    Van Gerven, Eva; Bruyneel, Luk; Panella, Massimiliano; Euwema, Martin; Sermeus, Walter; Vanhaecht, Kris

    2016-01-01

    Objective To examine individual, situational and organisational aspects that influence psychological impact and recovery of a patient safety incident on physicians, nurses and midwives. Design Cross-sectional, retrospective surveys of physicians, midwives and nurses. Setting 33 Belgian hospitals. Participants 913 clinicians (186 physicians, 682 nurses, 45 midwives) involved in a patient safety incident. Main outcome measures The Impact of Event Scale was used to retrospectively measure psychological impact of the safety incident at the time of the event and compare it with psychological impact at the time of the survey. Results Individual, situational as well as organisational aspects influenced psychological impact and recovery of a patient safety incident. Psychological impact is higher when the degree of harm for the patient is more severe, when healthcare professionals feel responsible for the incident and among female healthcare professionals. Impact of degree of harm differed across clinicians. Psychological impact is lower among more optimistic professionals. Overall, impact decreased significantly over time. This effect was more pronounced for women and for those who feel responsible for the incident. The longer ago the incident took place, the stronger impact had decreased. Also, higher psychological impact is related with the use of a more active coping and planning coping strategy, and is unrelated to support seeking coping strategies. Rendered support and a support culture reduce psychological impact, whereas a blame culture increases psychological impact. No associations were found with job experience and resilience of the health professional, the presence of a second victim support team or guideline and working in a learning culture. Conclusions Healthcare organisations should anticipate on providing their staff appropriate and timely support structures that are tailored to the healthcare professional involved in the incident and to the specific

  5. Repeat-until-success quantum repeaters

    Science.gov (United States)

    Bruschi, David Edward; Barlow, Thomas M.; Razavi, Mohsen; Beige, Almut

    2014-09-01

    We propose a repeat-until-success protocol to improve the performance of probabilistic quantum repeaters. Conventionally, these rely on passive static linear-optics elements and photodetectors to perform Bell-state measurements (BSMs) with a maximum success rate of 50%. This is a strong impediment for entanglement swapping between distant quantum memories. Every time a BSM fails, entanglement needs to be redistributed between the corresponding memories in the repeater link. The key ingredients of our scheme are repeatable BSMs. Under ideal conditions, these turn probabilistic quantum repeaters into deterministic ones. Under realistic conditions, our protocol too might fail. However, using additional threshold detectors now allows us to improve the entanglement generation rate by almost orders of magnitude, at a nominal distance of 1000 km, compared to schemes that rely on conventional BSMs. This improvement is sufficient to make the performance of our scheme comparable to the expected performance of some deterministic quantum repeaters.

  6. A novel AX+/BX- paradigm to assess fear learning and safety-signal processing with repeated-measure designs.

    Science.gov (United States)

    Kazama, Andy M; Schauder, Kimberly B; McKinnon, Michael; Bachevalier, Jocelyne; Davis, Michael

    2013-04-15

    One of the core symptoms of anxiety disorders, such as post-traumatic stress disorder, is the failure to overcome feelings of danger despite being in a safe environment. This deficit likely stems from an inability to fully process safety signals, which are cues in the environment that enable healthy individuals to over-ride fear in aversive situations. Studies examining safety signal learning in rodents, humans, and non-human primates currently rely on between-groups designs. Because repeated-measure designs reduce the number of subjects required, and facilitate a broader range of safety signal studies, the current project sought to develop a repeated-measures safety-signal learning paradigm in non-human primates. Twelve healthy rhesus macaques of both sexes received three rounds of auditory fear-potentiated startle training and testing using an AX+/BX- design with all visual cues. Cue AX was paired with an aversive blast of air, whereas the same X cue in compound with another B cue (BX) signaled the absence of an air blast. Hence, cue B served as a safety signal. Once animals consistently discriminated between the aversive (AX+) and safe (BX-) cues, measured by greater startle amplitude in the presence of AX vs. BX, they were tested for conditioned inhibition by eliciting startle in the presence of a novel ambiguous combined cue (AB). Similar to previous AX+/BX- studies, healthy animals rapidly learned to discriminate between the AX+ and BX- cues as well as demonstrate conditioned inhibition in the presence of the combined AB cue (i.e. lower startle amplitude in the presence of AB vs. AX). Additionally, animals performed consistently across three rounds of testing using three new cues each time. The results validate this novel method that will serve as a useful tool for better understanding the mechanisms for the regulation of fear and anxiety. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability

    Directory of Open Access Journals (Sweden)

    Liran Domachevsky

    2017-01-01

    Full Text Available Background. To investigate same day 18F-FDG (Fluorodeoxyglucose PET (Positron Emission Tomography/MR (Magnetic Resonance test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV and lean body mass (SUL in different locations in the liver. Methods. This prospective study was IRB approved with written informed consent obtained. 35 patients (20 women and 15 men, 61±11.2 years that performed a whole-body 18F-FDG PET/MR followed by liver-dedicated contrast-enhanced 18F-FDG PET/MR were included. SUV/L max, mean, and peak were measured inferior to, superior to, and at the right portal vein and in the left lobe of the liver. The coefficient of variation (CV and intraclass correlation coefficient (ICC were calculated and Bland-Altman plots were obtained. Results. The variability for SUV/L’s measurements was lowest inferior to the portal vein (<9.2% followed by measurements performed at the level of the portal vein (<14.6%. Conclusion. The area inferior to the portal vein is the most reliable location for hepatic 18F-FDG uptake measurements on PET/MR.

  8. Magnetic Resonance Spectroscopy in Patients with Insomnia: A Repeated Measurement Study.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Nissen, Christoph; Feige, Bernd; Baglioni, Chiara; Riemann, Dieter; Hennig, Jürgen; Lange, Thomas

    2016-01-01

    Chronic insomnia is one of the most prevalent central nervous system disorders. It is characterized by increased arousal levels, however, the neurobiological causes and correlates of hyperarousal in insomnia remain to be further determined. In the current study, magnetic resonance spectroscopy was used in the morning and evening in a well-characterized sample of 20 primary insomnia patients (12 females; 8 males; 42.7 ± 13.4 years) and 20 healthy good sleepers (12 females; 8 males; 44.1 ± 10.6 years). The most important inhibitory and excitatory neurotransmitters of the central nervous system, γ-aminobutyric acid (GABA) and glutamate/glutamine (Glx), were assessed in the anterior cingulate cortex (ACC) and dorsolateral prefrontal cortex (DLPFC). The primary hypothesis, a diurnal effect on GABA levels in patients with insomnia, could not be confirmed. Moreover, the current results did not support previous findings of altered GABA levels in individuals with insomnia. Exploratory analyses, however, suggested that GABA levels in the ACC may be positively associated with habitual sleep duration, and, thus, reduced GABA levels may be a trait marker of objective sleep disturbances. Moreover, there was a significant GROUP x MEASUREMENT TIME interaction effect on Glx in the DLPFC with increasing Glx levels across the day in the patients but not in the control group. Therefore, Glx levels may reflect hyperarousal at bedtime in those with insomnia. Future confirmatory studies should include larger sample sizes to investigate brain metabolites in different subgroups of insomnia.

  9. Using high-dynamic-range digital repeat photography to measure plant phenology in a subarctic mire.

    Science.gov (United States)

    Garnello, A.; Dye, D. G.; Bogle, R.; Vogel, J.; Saleska, S. R.; Crill, P. M.

    2015-12-01

    A novel Visual Imaging System (VIS) was designed and deployed in a subarctic mire (68° 20' N, 19° 03'E) aimed at cataloging plant biological changes (phenology) and analyzing seasonal color shifts in relation to micrometeorological data along the summer growing season: June-November, 2015. The VIS is designed as a tower-based, solar-powered, automated phenology camera (Phenocam) that collects red, green, blue (RGB) and near-infrared (NIR) landscape images in High Dynamic Range (HDR) with fully programmable temporal resolution. HDR composite images are made through combining a series of rapid-capture photos with incremental increases of exposure times and a fixed focus, minimizing the spatial and visual data lost from shadows or from the over-saturation of light. This visual record of ecosystem phenology stages (Phenophases) is being used to (1) investigate vegetation-dependent spectral indices; (2) establish a cross-year comparison record of Phenophase seasonality; (3) investigate meteorological-dependent vegetation Phenophases; (4) provide ground-truthing measurements that enhance broader spatial-scale remote sensing analyses of subarctic wetlands.

  10. A Finite Mixture of Nonlinear Random Coefficient Models for Continuous Repeated Measures Data.

    Science.gov (United States)

    Kohli, Nidhi; Harring, Jeffrey R; Zopluoglu, Cengiz

    2016-09-01

    Nonlinear random coefficient models (NRCMs) for continuous longitudinal data are often used for examining individual behaviors that display nonlinear patterns of development (or growth) over time in measured variables. As an extension of this model, this study considers the finite mixture of NRCMs that combine features of NRCMs with the idea of finite mixture (or latent class) models. The efficacy of this model is that it allows the integration of intrinsically nonlinear functions where the data come from a mixture of two or more unobserved subpopulations, thus allowing the simultaneous investigation of intra-individual (within-person) variability, inter-individual (between-person) variability, and subpopulation heterogeneity. Effectiveness of this model to work under real data analytic conditions was examined by executing a Monte Carlo simulation study. The simulation study was carried out using an R routine specifically developed for the purpose of this study. The R routine used maximum likelihood with the expectation-maximization algorithm. The design of the study mimicked the output obtained from running a two-class mixture model on task completion data.

  11. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  12. Are There Linguistic Markers of Suicidal Writing That Can Predict the Course of Treatment? A Repeated Measures Longitudinal Analysis.

    Science.gov (United States)

    Brancu, Mira; Jobes, David; Wagner, Barry M; Greene, Jeffrey A; Fratto, Timothy A

    2016-07-02

    The purpose of this pilot study was to predict resolution of suicidal ideation and risk over the course of therapy among suicidal outpatients (N = 144) using a novel method for analyzing Self- verses Relationally oriented qualitative written responses to the Suicide Status Form (SSF). A content analysis software program was used to extract word counts and a repeated measures longitudinal design was implemented to assess improvement over time. Patients with primarily Relationally focused word counts were more likely to have a quicker suicide risk resolution than those with more Self-focused word counts (6-7 sessions versus 17-18 sessions). Implications of these data are discussed, including the potential for enhancing treatment outcomes using this method with individuals entering treatment.

  13. A Bayesian model for repeated measures zero-inflated count data with application to outpatient psychiatric service use

    Science.gov (United States)

    Neelon, Brian H.; O’Malley, A. James; Normand, Sharon-Lise T.

    2009-01-01

    In applications involving count data, it is common to encounter an excess number of zeros. In the study of outpatient service utilization, for example, the number of utilization days will take on integer values, with many subjects having no utilization (zero values). Mixed-distribution models, such as the zero-inflated Poisson (ZIP) and zero-inflated negative binomial (ZINB), are often used to fit such data. A more general class of mixture models, called hurdle models, can be used to model zero-deflation as well as zero-inflation. Several authors have proposed frequentist approaches to fitting zero-inflated models for repeated measures. We describe a practical Bayesian approach which incorporates prior information, has optimal small-sample properties, and allows for tractable inference. The approach can be easily implemented using standard Bayesian software. A study of psychiatric outpatient service use illustrates the methods. PMID:21339863

  14. The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains.

    Science.gov (United States)

    Iannetta, Danilo; Qahtani, Ahmad; Mattioni Maturana, Felipe; Murias, Juan Manuel

    2017-09-01

    A breaking-point in the near-infrared spectroscopy (NIRS)-derived deoxygenated haemoglobin ([HHb]) profile towards the end of a ramp incremental (RI) cycling test has been associated to the respiratory compensation point (RCP). Despite the physiological value of this measure, its repeatability remains unknown. The aim was to examine the repeatability of the [HHb] breaking-point ([HHb]BP) and its association to RCP during a RI cycling test. A repeated measures design was performed on 11 males (30.5±8.4 year; 76.5±8.4kg) and 4 females (30.5±5.9 year; 61.9±4.4 Kg). Gas exchange and NIRS [HHb] data were collected during RI tests performed on two different days separated by 48h. The [HHb]BP and the RCP were determined and compared for each trial. The [HHb]BP and the respiratory compensation point (RCP) occurred at the same VO2 in test 1 and test 2 ([HHb]BP: 3.49±0.52Lmin(-1) test 1; 3.48±0.45Lmin(-1) test 2; RCP: 3.38±0.40Lmin(-1) test 1; 3.38±0.44Lmin(-1) test 2) (P>0.05). The VO2 associated with the [HHb]BP and the VO2 at RCP were not significantly different from each other either in test 1 as well as in test 2 (P>0.05). Neither test 1 nor test 2 showed significant mean average error between the VO2 at the [HHb]BP and RCP using Bland & Altman plots. The [HHb]BP is a repeatable measure that consistently occurs towards the end of a RI test. The association between the [HHb]BP and the RCP reinforces the idea that these parameters may share similar mechanistic basis. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Detection of quasi-periodic processes in repeated measurements: New approach for the fitting and clusterization of different data

    Science.gov (United States)

    Nigmatullin, R.; Rakhmatullin, R.

    2014-12-01

    Many experimentalists were accustomed to think that any independent measurement forms a non-correlated measurement that depends weakly from others. We are trying to reconsider this conventional point of view and prove that similar measurements form a strongly-correlated sequence of random functions with memory. In other words, successive measurements "remember" each other at least their nearest neighbors. This observation and justification on real data help to fit the wide set of data based on the Prony's function. The Prony's decomposition follows from the quasi-periodic (QP) properties of the measured functions and includes the Fourier transform as a partial case. New type of decomposition helps to obtain a specific amplitude-frequency response (AFR) of the measured (random) functions analyzed and each random function contains less number of the fitting parameters in comparison with its number of initial data points. Actually, the calculated AFR can be considered as the generalized Prony's spectrum (GPS), which will be extremely useful in cases where the simple model pretending on description of the measured data is absent but vital necessity of their quantitative description is remained. These possibilities open a new way for clusterization of the initial data and new information that is contained in these data gives a chance for their detailed analysis. The electron paramagnetic resonance (EPR) measurements realized for empty resonator (pure noise data) and resonator containing a sample (CeO2 in our case) confirmed the existence of the QP processes in reality. But we think that the detection of the QP processes is a common feature of many repeated measurements and this new property of successive measurements can attract an attention of many experimentalists. To formulate some general conditions that help to identify and then detect the presence of some QP process in the repeated experimental measurements. To find a functional equation and its solution that

  16. Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, L.; Douglas, N.H.M.; Collins, D.J.; Giles, S.L.; O' Flynn, E.A.M.; Orton, M.; DeSouza, N.M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK and EPSRC Cancer Imaging Centre, Surrey (United Kingdom)

    2014-02-15

    To establish repeatability of apparent diffusion coefficients (ADCs) acquired from free-breathing diffusion-weighted magnetic resonance imaging (DW-MRI) in malignant lung lesions and investigate effects of lesion size, location and respiratory motion. Thirty-six malignant lung lesions (eight patients) were examined twice (1- to 5-h interval) using T1-weighted, T2-weighted and axial single-shot echo-planar DW-MRI (b = 100, 500, 800 s/mm{sup 2}) during free-breathing. Regions of interest around target lesions on computed b = 800 s/mm{sup 2} images by two independent observers yielded ADC values from maps (pixel-by-pixel fitting using all b values and a mono-exponential decay model). Intra- and inter-observer repeatability was assessed per lesion, per patient and by lesion size (> or <2 cm) or location. ADCs were similar between observers (mean ± SD, 1.15 ± 0.28 x 10{sup -3} mm{sup 2}/s, observer 1; 1.15 ± 0.29 x 10{sup -3} mm{sup 2}/s, observer 2). Intra-observer coefficients of variation of the mean [median] ADC per lesion and per patient were 11 % [11.4 %], 5.7 % [5.7 %] for observer 1 and 9.2 % [9.5 %], 3.9 % [4.7 %] for observer 2 respectively; inter-observer values were 8.9 % [9.3 %] (per lesion) and 3.0 % [3.7 %] (per patient). Inter-observer coefficient of variation (CoV) was greater for lesions <2 cm (n = 20) compared with >2 cm (n = 16) (10.8 % vs 6.5 % ADC{sub mean}, 11.3 % vs 6.7 % ADC{sub median}) and for mid (n = 14) vs apical (n = 9) or lower zone (n = 13) lesions (13.9 %, 2.7 %, 3.8 % respectively ADC{sub mean}; 14.2 %, 2.8 %, 4.7 % respectively ADC{sub median}). Free-breathing DW-MRI of whole lung achieves good intra- and inter-observer repeatability of ADC measurements in malignant lung tumours. (orig.)

  17. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences.

  18. 躯体X线测量板的研制和应用%Validation and repeatability of Limb X Film Measuring Plate

    Institute of Scientific and Technical Information of China (English)

    卫小春; 柴旭峰; 许趁心

    2008-01-01

    Objective To study the efficacy and repeatability of the Limb X Film Measuring Plate (LXMP)in clinical x film measurement of lengths and angles of limbs.Methods The LXMP was de- signed and manufactured for testing.Three known points in 9 templates were taken as golden standards.which were to be compared with measuring results of these projected points on the X film for testing efficacy of LXMP.Twenty-one patients with knees osteoarthritis were selected.The lengths and angles of their lower limbs were measured twice with the help of LXMP by an observer at different time intervals for testing in. Tra-observer repeatability.Two observers measured once on films at the same time for testing inter-observer repeatability.The correlation coefficients,mean absolute difierences between the repeated measurements,and error rate were calculated. Results The points on LXMP could be seen clearly on X film.Validation tests showed the differences in angle measurement between golden standards and measuring results for those pro- jeted points on the X film were insignificant.with mean absolute difference being O.10.-0.21,error rate being 0.12%-3.15%and r being close to 1.The differences in length measurement were insignificant ei- ther,with mean absolute differenee being 0.05 cm-0.16 cm.error rate being 0.12%-o.28%and r being close to 1.The intra-observer repeatability test for beth angles and lengths showed that r was close to I.mean absolute diffefences 0.55.and 0.1-0.37cm and error rate 0.3l%-O.97%.while the inter-observer re- peatability test showed that r was close to 1.mean absolute difierences o.39.and0.05-0.13cm and error rate O.16%-O.35%. Conclusion The Limb X Film Measuring Plate Can be used for accurately mcasuring limb lengths and angles with good efficacy and repeatability.%目的 介绍躯体X线测量板的制作方法 ,探讨其有效性、重复性,为临床X线测量提供一套精确、实用、经济的方法 和工具.方法 设计和制作躯体X线

  19. Repeated-sprint cycling does not induce respiratory muscle fatigue in active adults: measurements from the powerbreathe® inspiratory muscle trainer.

    Science.gov (United States)

    Minahan, Clare; Sheehan, Beth; Doutreband, Rachel; Kirkwood, Tom; Reeves, Daniel; Cross, Troy

    2015-03-01

    This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., 'S-Index') before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP) values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p Repeated-sprint cycling had no effect on respiratory muscle strength as measured by the POWERbreathe® (p > 0.99) and during the Mueller maneuver (p > 0.99). The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults. Key pointsThe S-Index as measured by the POWERbreathe® is a reliable measure of respiratory muscle strengthThe S-Index does not accurately reflect maximal inspiratory pressure obtained from a Mueller maneuverRepeated-sprint cycling does not induce respiratory muscle fatigue as measured by the POWERbreathe® and the Manometer.

  20. Ambient particulate air pollution and circulating antioxidant enzymes: A repeated-measure study in healthy adults in Beijing, China.

    Science.gov (United States)

    Wu, Shaowei; Wang, Bin; Yang, Di; Wei, Hongying; Li, Hongyu; Pan, Lu; Huang, Jing; Wang, Xin; Qin, Yu; Zheng, Chanjuan; Shima, Masayuki; Deng, Furong; Guo, Xinbiao

    2016-01-01

    The association of systemic antioxidant activity with ambient air pollution has been unclear. A panel of 40 healthy college students underwent repeated blood collection for 12 occasions under three exposure scenarios before and after relocating from a suburban area to an urban area in Beijing, China in 2010-2011. We measured various air pollutants including fine particles (PM2.5) and determined circulating levels of antioxidant enzymes extracellular superoxide dismutase (EC-SOD) and glutathione peroxidase 1 (GPX1) in the laboratory. An interquartile range increase of 63.4 μg/m(3) at 3-d PM2.5 moving average was associated with a 6.3% (95% CI: 0.6, 12.4) increase in EC-SOD and a 5.5% (95% CI: 1.3, 9.8) increase in GPX1. Several PM2.5 chemical constituents, including negative ions (nitrate and chloride) and metals (e.g., iron and strontium), were consistently associated with increases in EC-SOD and GPX1. Our results support activation of circulating antioxidant enzymes following exposure to particulate air pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Are diagnostic criteria for acute malnutrition affected by hydration status in hospitalized children? A repeated measures study

    Directory of Open Access Journals (Sweden)

    Fegan Gregory

    2011-09-01

    Full Text Available Abstract Introduction Dehydration and malnutrition commonly occur together among ill children in developing countries. Dehydration (change in total body water is known to alter weight. Although muscle tissue has high water content, it is not known whether mid-upper arm circumference (MUAC may be altered by changes in tissue hydration. We aimed to determine whether rehydration alters MUAC, MUAC Z score (MUACz, weight-for-length Z-score (WFLz and classification of nutritional status among hospitalised Kenyan children admitted with signs of dehydration. Study procedure We enrolled children aged from 3 months to 5 years admitted to a rural Kenyan district hospital with clinical signs compatible with dehydration, and without kwashiorkor. Anthropometric measurements were taken at admission and repeated after 48 hours of treatment, which included rehydration by WHO protocols. Changes in weight observed during this period were considered to be due to changes in hydration status. Results Among 325 children (median age 11 months the median weight gain (rehydration after 48 hours was 0.21 kg, (an increase of 2.9% of admission body weight. Each 1% change in weight was associated with a 0.40 mm (95% CI: 0.30 to 0.44 mm, p Conclusion MUAC is less affected by dehydration than WFLz and is therefore more suitable for nutritional assessment of ill children. However, both WFLz and MUAC misclassify SAM among dehydrated children. Nutritional status should be re-evaluated following rehydration, and management adjusted accordingly.

  2. Selecting a linear mixed model for longitudinal data: repeated measures analysis of variance, covariance pattern model, and growth curve approaches.

    Science.gov (United States)

    Liu, Siwei; Rovine, Michael J; Molenaar, Peter C M

    2012-03-01

    With increasing popularity, growth curve modeling is more and more often considered as the 1st choice for analyzing longitudinal data. Although the growth curve approach is often a good choice, other modeling strategies may more directly answer questions of interest. It is common to see researchers fit growth curve models without considering alterative modeling strategies. In this article we compare 3 approaches for analyzing longitudinal data: repeated measures analysis of variance, covariance pattern models, and growth curve models. As all are members of the general linear mixed model family, they represent somewhat different assumptions about the way individuals change. These assumptions result in different patterns of covariation among the residuals around the fixed effects. In this article, we first indicate the kinds of data that are appropriately modeled by each and use real data examples to demonstrate possible problems associated with the blanket selection of the growth curve model. We then present a simulation that indicates the utility of Akaike information criterion and Bayesian information criterion in the selection of a proper residual covariance structure. The results cast doubt on the popular practice of automatically using growth curve modeling for longitudinal data without comparing the fit of different models. Finally, we provide some practical advice for assessing mean changes in the presence of correlated data.

  3. Repeated measurements of blood lactate concentration as a prognostic marker in horses with acute colitis evaluated with classification and regression trees (CART) and random forest analysis.

    Science.gov (United States)

    Petersen, M B; Tolver, A; Husted, L; Tølbøll, T H; Pihl, T H

    2016-07-01

    The objective of this study was to investigate the prognostic value of single and repeated measurements of blood l-lactate (Lac) and ionised calcium (iCa) concentrations, packed cell volume (PCV) and plasma total protein (TP) concentration in horses with acute colitis. A total of 66 adult horses admitted with acute colitis (2 mmol/L (sensitivity, 0.72; specificity, 0.8). In conclusion, blood lactate concentration measured at admission and repeated 6 h later aided the prognostic evaluation of horses with acute colitis in this population with a very high mortality rate. This should allow clinicians to give a more reliable prognosis for the horse.

  4. Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experience.

    Science.gov (United States)

    Patel, Neil; Dodsworth, Melissa; Mills, John F

    2011-05-01

    To assess (1) agreement between the ultrasonic cardiac output monitor (USCOM) 1A device for measurement of cardiac output in newborn infants and conventional echocardiography (ECHO), (2) repeatability of USCOM measurements and (3) agreement between novice and expert users of the USCOM. A prospective observational study. The Neonatal Unit at the Royal Children's Hospital, Melbourne, Australia. 56 term and near-term infants, with no evidence of structural or functional cardiovascular disease, or haemodynamic shunts. Agreement between ECHO and USCOM was assessed by paired measurements of ventricular outputs by a single experienced user. Repeatability was assessed using five repeated measurements in 10 infants. Agreement between five novices and one expert user was assessed by paired USCOM measurements over 30 training measurements. Agreement between USCOM and ECHO for left ventricular output (LVO) was (bias, ±limits of agreement, mean % error): 14, ±108 ml/kg/min, 43%, and for right ventricular output (RVO): -59, ±160, ml/kg/min, 57%. Intra-observer repeatability was 6.7% for USCOM LVO and 3.6% for ECHO LVO. After five training measurements, the mean difference between USCOM measures of LVO by novice and expert users was less than 50 ml/kg/min, but with variability. Repeatability of USCOM measures is high in newborn infants. New users can be trained quickly, but with high inter-user variability. Agreement between USCOM and conventional ECHO is broad, and worse for RVO and LVO. Further studies are required to assess the ability of the device to detect clinically significant changes in infant cardiac output.

  5. Quantum repeated games revisited

    CERN Document Server

    Frackiewicz, Piotr

    2011-01-01

    We present a scheme for playing quantum repeated 2x2 games based on the Marinatto and Weber's approach to quantum games. As a potential application, we study twice repeated Prisoner's Dilemma game. We show that results not available in classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games.

  6. Single and repeated moderate consumption of native or dealcoholized red wine show different effects on antioxidant parameters in blood and DNA strand breaks in peripheral leukocytes in healthy volunteers: a randomized controlled trial [ISRCTN68505294

    Directory of Open Access Journals (Sweden)

    Spengler Ulrich

    2005-11-01

    Full Text Available Abstract Background Red wine (RW is rich in antioxidant polyphenols that might protect from oxidative stress related diseases, such as cardiovascular disease and cancer. Antioxidant effects after single ingestion of RW or dealcoholized RW (DRW have been observed in several studies, but results after regular consumption are contradictory. Thus, we examined if single or repeated consumption of moderate amounts of RW or DRW exert antioxidant activity in vivo. Methods Total phenolic content and concentration of other antioxidants in plasma/serum, total antioxidant capacity (TEAC in plasma as well as DNA strand breaks in peripheral leukocytes were measured in healthy non-smokers A before, 90 and 360 min after ingestion of one glass of RW, DRW or water; B before and after consumption of one glass of RW or DRW daily for 6 weeks. DNA strand breaks (SB were determined by single cell gel electrophoresis (Comet Assay in untreated cells and after induction of oxidative stress ex vivo with H2O2 (300 μM, 20 min. Results Both RW and DRW transiently increased total phenolic content in plasma after single consumption, but only RW lead to a sustained increase if consumed regularly. Plasma antioxidant capacity was not affected by single or regular consumption of RW or DRW. Effects of RW and DRW on DNA SB were conflicting. DNA strand breaks in untreated cells increased after a single dose of RW and DRW, whereas H2O2 induced SB were reduced after DRW. In contrast, regular RW consumption reduced SB in untreated cells but did not affect H2O2 induced SB. Conclusion The results suggest that consumption of both RW and DRW leads to an accumulation of phenolic compounds in plasma without increasing plasma antioxidant capacity. Red wine and DRW seem to affect the occurrence of DNA strand breaks, but this cannot be referred to antioxidant effects.

  7. Measurement of Surface Displacement and Deformation of Mass Movements Using Least Squares Matching of Repeat High Resolution Satellite and Aerial Images

    Directory of Open Access Journals (Sweden)

    Misganu Debella-Gilo

    2012-01-01

    Full Text Available Displacement and deformation are fundamental measures of Earth surface mass movements such as glacier flow, rockglacier creep and rockslides. Ground-based methods of monitoring such mass movements can be costly, time consuming and limited in spatial and temporal coverage. Remote sensing techniques, here matching of repeat optical images, are increasingly used to obtain displacement and deformation fields. Strain rates are usually computed in a post-processing step based on the gradients of the measured velocity field. This study explores the potential of automatically and directly computing velocity, rotation and strain rates on Earth surface mass movements simultaneously from the matching positions and the parameters of the geometric transformation models using the least squares matching (LSM approach. The procedures are exemplified using bi-temporal high resolution satellite and aerial images of glacier flow, rockglacier creep and land sliding. The results show that LSM matches the images and computes longitudinal strain rates, transverse strain rates and shear strain rates reliably with mean absolute deviations in the order of 10−4 (one level of significance below the measured values as evaluated on stable grounds. The LSM also improves the accuracy of displacement estimation of the pixel-precision normalized cross-correlation by over 90% under ideal (simulated circumstances and by about 25% for real multi-temporal images of mass movements.

  8. Detecting variable responses in time-series using repeated measures ANOVA: Application to physiologic challenges [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Paul M. Macey

    2016-07-01

    Full Text Available We present an approach to analyzing physiologic timetrends recorded during a stimulus by comparing means at each time point using repeated measures analysis of variance (RMANOVA. The approach allows temporal patterns to be examined without an a priori model of expected timing or pattern of response. The approach was originally applied to signals recorded from functional magnetic resonance imaging (fMRI volumes-of-interest (VOI during a physiologic challenge, but we have used the same technique to analyze continuous recordings of other physiological signals such as heart rate, breathing rate, and pulse oximetry. For fMRI, the method serves as a complement to whole-brain voxel-based analyses, and is useful for detecting complex responses within pre-determined brain regions, or as a post-hoc analysis of regions of interest identified by whole-brain assessments. We illustrate an implementation of the technique in the statistical software packages R and SAS. VOI timetrends are extracted from conventionally preprocessed fMRI images. A timetrend of average signal intensity across the VOI during the scanning period is calculated for each subject. The values are scaled relative to baseline periods, and time points are binned. In SAS, the procedure PROC MIXED implements the RMANOVA in a single step. In R, we present one option for implementing RMANOVA with the mixed model function “lme”. Model diagnostics, and predicted means and differences are best performed with additional libraries and commands in R; we present one example. The ensuing results allow determination of significant overall effects, and time-point specific within- and between-group responses relative to baseline. We illustrate the technique using fMRI data from two groups of subjects who underwent a respiratory challenge. RMANOVA allows insight into the timing of responses and response differences between groups, and so is suited to physiologic testing paradigms eliciting complex

  9. The Effects of Group Leader Learning Style on Student Knowledge Gain in a Leadership Camp Setting: A Repeated-Measures Experiment

    Science.gov (United States)

    Brown, Nicholas R.; Terry, Robert, Jr.

    2013-01-01

    Many state FFA associations conduct summer camps focusing on leadership and personal development for FFA members. Interestingly, little research has been conducted on the impact or outcomes of these common activities. The purpose of this split-plot factorial repeated-measures experiment was to assess the level of campers' learning of the…

  10. Power and sample size for the S:T repeated measures design combined with a linear mixed-effects model allowing for missing data.

    Science.gov (United States)

    Tango, Toshiro

    2017-02-13

    Tango (Biostatistics 2016) proposed a new repeated measures design called the S:T repeated measures design, combined with generalized linear mixed-effects models and sample size calculations for a test of the average treatment effect that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size compared with the simple pre-post design. In this article, we present formulas for calculating power and sample sizes for a test of the average treatment effect allowing for missing data within the framework of the S:T repeated measures design with a continuous response variable combined with a linear mixed-effects model. Examples are provided to illustrate the use of these formulas.

  11. Fluorescence-based measurement of cystine uptake through xCT shows requirement for ROS detoxification in activated lymphocytes.

    Science.gov (United States)

    Siska, Peter J; Kim, Bumki; Ji, Xiangming; Hoeksema, Megan D; Massion, Pierre P; Beckermann, Kathryn E; Wu, Jianli; Chi, Jen-Tsan; Hong, Jiyong; Rathmell, Jeffrey C

    2016-11-01

    T and B lymphocytes undergo metabolic re-programming upon activation that is essential to allow bioenergetics, cell survival, and intermediates for cell proliferation and function. To support changes in the activity of signaling pathways and to provide sufficient and necessary intracellular metabolites, uptake of extracellular nutrients increases sharply with metabolic re-programming. One result of increased metabolic activity can be reactive oxygen species (ROS), which can be toxic when accumulated in excess. Uptake of cystine allows accumulation of cysteine that is necessary for glutathione synthesis and ROS detoxification. Cystine uptake is required for T cell activation and function but measurements based on radioactive labeling do not allow analysis on single cell level. Here we show the critical role for cystine uptake in T cells using a method for measurement of cystine uptake using a novel CystineFITC probe. T cell receptor stimulation lead to upregulation of the cystine transporter xCT (SLC7a11) and increased cystine uptake in CD4+ and CD8+ human T cells. Similarly, lipopolysaccharide stimulation increased cystine uptake in human B cells. The CystineFITC probe was not toxic and could be metabolized to prevent cystine starvation induced cell death. Furthermore, blockade of xCT or competition with natural cystine decreased uptake of CystineFITC. CystineFITC is thus a versatile tool that allows measurement of cystine uptake on single cell level and shows the critical role for cystine uptake for T cell ROS regulation and activation.

  12. Predictors and Variability of Repeat Measurements of Urinary Phenols and Parabens in a Cohort of Shanghai Women and Men

    Science.gov (United States)

    Buckley, Jessie P.; Yang, Gong; Liao, Linda M.; Satagopan, Jaya; Calafat, Antonia M.; Matthews, Charles E.; Cai, Qiuyin; Ji, Bu-Tian; Cai, Hui; Wolff, Mary S.; Rothman, Nathaniel; Zheng, Wei; Xiang, Yong-Bing; Shu, Xiao-Ou; Gao, Yu-Tang; Chow, Wong-Ho

    2014-01-01

    , under certain circumstances, among women. Citation: Engel LS, Buckley JP, Yang G, Liao LM, Satagopan J, Calafat AM, Matthews CE, Cai Q, Ji BT, Cai H, Engel SM, Wolff MS, Rothman N, Zheng W, Xiang YB, Shu XO, Gao YT, Chow WH. 2014. Predictors and variability of repeat measurements of urinary phenols and parabens in a cohort of Shanghai women and men. Environ Health Perspect 122:733–740; http://dx.doi.org/10.1289/ehp.1306830 PMID:24659570

  13. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures

    Directory of Open Access Journals (Sweden)

    Karahalios Amalia

    2012-07-01

    Full Text Available Abstract Background Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007; Vandenbroucke et al. (PLoS Med, 4:e297, 2007 and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009 recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. Methods A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Results Among the 82 papers meeting the inclusion criteria, only 35 (43% reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83% described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n = 54, 66%. Other papers used more sophisticated methods including multiple imputation (n = 5 or fully Bayesian modeling (n = 1. Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n = 7, the missing indicator method (n = 1, and mean value substitution (n = 3. For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. Conclusions This review highlights the inconsistent reporting of missing data in cohort studies and the continuing

  14. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures.

    Science.gov (United States)

    Karahalios, Amalia; Baglietto, Laura; Carlin, John B; English, Dallas R; Simpson, Julie A

    2012-07-11

    Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007); Vandenbroucke et al. (PLoS Med, 4:e297, 2007) and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009) recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Among the 82 papers meeting the inclusion criteria, only 35 (43%) reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83%) described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n=54, 66%). Other papers used more sophisticated methods including multiple imputation (n=5) or fully Bayesian modeling (n=1). Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n=7), the missing indicator method (n=1), and mean value substitution (n=3). For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. This review highlights the inconsistent reporting of missing data in cohort studies and the continuing use of inappropriate methods to handle missing data in the analysis. Epidemiological journals

  15. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    ABSTRACT: BACKGROUND: Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...... questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants "recovered" at a specific time point? This question was answered using logistic regression analysis. 3: What is the time...

  16. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction and...

  17. Heart rate variability and DNA methylation levels are altered after short-term metal fume exposure among occupational welders: a repeated-measures panel study

    OpenAIRE

    2014-01-01

    Background: In occupational settings, boilermakers are exposed to high levels of metallic fine particulate matter (PM2.5) generated during the welding process. The effect of welding PM2.5 on heart rate variability (HRV) has been described, but the relationship between PM2.5, DNA methylation, and HRV is not known. Methods: In this repeated-measures panel study, we recorded resting HRV and measured DNA methylation levels in transposable elements Alu and long interspersed nuclear element-1 (LINE...

  18. Repeated measures dose-finding design with time-trend detection in the presence of correlated toxicity data.

    Science.gov (United States)

    Yin, Jun; Paoletti, Xavier; Sargent, Daniel J; Mandrekar, Sumithra J

    2017-08-01

    Phase I trials are designed to determine the safety, tolerability, and recommended phase 2 dose of therapeutic agents for subsequent testing. The dose-finding paradigm has thus traditionally focused on identifying the maximum tolerable dose of an agent or combination therapy under the assumption that there is a non-decreasing relationship between dose-toxicity and dose-efficacy. The dose is typically determined based on the probability of severe toxicity observed during the first treatment cycle. A novel endpoint, the total toxicity profile, was previously developed to account for the multiple toxicity types and grades experienced in the first cycle. More recently, this was extended to a repeated measures design based on the total toxicity profile to account for longitudinal toxicities over multiple treatment cycles in the absence of within-patient correlation. In this work, we propose to extend the design in the presence of within-patient correlation. Furthermore, we provide a framework to detect a toxicity time trend (toxicity increasing, decreasing, or stable) over multiple treatment cycles. We utilize a linear mixed model in the Bayesian framework, with the addition of Bayesian risk functions for decision-making in dose assignment. The performance of this design was evaluated using simulation studies and real data from a phase I trial. We demonstrated that using available toxicity data from all cycles of treatment improves the accuracy of maximum tolerated dose identification and allows for the detection of a time trend. The performance is consistent regardless of the strength of the within-patient correlation. In addition, the use of a quasi-continuous total toxicity profile score significantly increased the power to detect time trends compared to when binary data only were used. The increased interest in molecularly targeted agents and immunotherapies in oncology necessitates innovative phase I study designs. Our proposed framework provides a tool to tackle

  19. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    Science.gov (United States)

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  20. Young investigator challenge: Atypia of undetermined significance in thyroid FNA: Standardized terminology without standardized management--a closer look at repeat FNA and quality measures.

    Science.gov (United States)

    Brandler, Tamar C; Aziz, Mohamed S; Coutsouvelis, Constantinos; Rosen, Lisa; Rafael, Oana C; Souza, Fabiola; Jelloul, Fatima-Zahra; Klein, Melissa A

    2016-01-01

    The Bethesda system (TBS) for the reporting of thyroid cytopathology established the category of atypia of undetermined significance (AUS) with a 7% target rate and a 5% to 15% implied malignancy risk. Recent literature has reported a broad range of AUS rates, subsequent malignancy rates, and discrepant results from repeat fine-needle aspiration (FNA) versus surgical follow-up. Therefore, this study examined AUS data from the Hofstra North Shore-LIJ School of Medicine to determine the best clinical follow-up. Thyroid aspirates interpreted as AUS in 2012-2014 at the Hofstra North Shore-LIJ School of Medicine were collected. Repeat FNA and surgical follow-up data were tabulated to establish AUS, secondary AUS (diagnosed upon repeat FNA follow-up of a primary FNA AUS diagnosis), atypia of undetermined significance/malignancy (AUS:M) ratios (according to the TBS categories), and malignancy rates for AUS. The AUS rate was 8.5% (976/11,481), and there was follow-up data for 545 cases. The AUS:M ratio was 2.0. Repeat FNA was performed for 281 cases; 57 proceeded to surgical intervention. Repeat FNA reclassified 71.17% of the cases. The malignancy rates for AUS cases proceeding directly to surgery and for those receiving a surgical intervention after a repeat AUS diagnosis were 33.33% and 43.75%, respectively. Repeat FNA resulted in definitive diagnostic reclassification for 67.61% of primary AUS cases and reduced the number of patients triaged to surgery, with 56.58% of the cases recategorized as benign. Cases undergoing surgery after repeat AUS had a higher malignancy rate than those going straight to surgery, and this emphasizes the value of repeat FNA in selecting surgical candidates. In addition, this study highlights the utility of AUS rate monitoring as a quality measure that has contributed to the ability of the Hofstra North Shore-LIJ School of Medicine to adhere closely to TBS recommendations. © 2016 American Cancer Society.

  1. The effects of repeated-sprint training on field-based fitness measures: a meta-analysis of controlled and non-controlled trials.

    Science.gov (United States)

    Taylor, Jonathan; Macpherson, Tom; Spears, Iain; Weston, Matthew

    2015-06-01

    Repeated-sprint training appears to be an efficient and practical means for the simultaneous development of different components of fitness relevant to team sports. Our objective was to systematically review the literature and meta-analyse the effect of repeated-sprint training on a selection of field-based measures of athletic performance, i.e. counter-movement jump, 10 m sprint, 20 m sprint, 30 m sprint, repeated-sprint ability and high-intensity intermittent running performance. The SPORTDiscus, PubMed, MEDLINE and Web of Science databases were searched for original research articles. Search terms included 'repeated-sprint training', 'sprint training', 'aerobic endurance', 'repeated-sprint ability', 'counter-movement jump' and 'sprint performance'. Inclusion criteria included intervention consisting of a series of ≤10 s sprints with ≤60 s recovery; trained participants; intervention duration of 2-12 weeks; field-based fitness measures; running- or cycling-based intervention; published up to, and including, February 2014. Our final dataset included six trials for counter-movement jump (two controlled trials), eight trials for 10 m sprint, four trials for 20 m sprint (three controlled trials), two trials for 30 m sprint, eight trials for repeated-sprint ability and three trials for high-intensity intermittent running performance. Analyses were conducted using comprehensive meta-analysis software. Uncertainty in the meta-analysed effect of repeated-sprint training was expressed as 95% confidence limits (CL), along with the probability that the true value of the effect was trivial, beneficial or harmful. Magnitude-based inferences were based on standardised thresholds for small, moderate and large changes of 0.2, 0.6 and 1.2 standard deviations, respectively. Repeated-sprint training had a likely small beneficial effect in non-controlled counter-movement jump trials (effect size 0.33; 95% CL ±0.30), with a possibly moderate beneficial effect in controlled

  2. Repeatability of Harris Corner Detector

    Institute of Scientific and Technical Information of China (English)

    HU Lili

    2003-01-01

    Interest point detectors are commonly employed to reduce the amount of data to be processed. The ideal interest point detector would robustly select those features which are most appropriate or salient for the application and data at hand. This paper shows that interest points are geometrically stable under different transformations.This property makes interest points very successful in the context of image matching. To measure this property quantatively, we introduce a evaluation criterion: repeatability rate.

  3. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Virgil [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Della Torre, Edward; Bennett, Lawrence H. [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States); ElBidweihy, Hatem, E-mail: Hatem@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States)

    2014-02-15

    The Gd{sub 5}Ge{sub 2}Si{sub 2} alloy and the off-stoichiometric Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd{sub 5}Ge{sub 2}Si{sub 2} and Ni{sub 50}Mn{sub 35}In{sub 15} alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  4. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    controlled to great precision, but in a Cubesat , there may be no attitude determination at all. Such a Cubesat might treat sun angle and tumbling rates as...could be sensitive to small differences in motor controller timing. In these cases, the analyst might choose to model the entire deployment path, with...knowledge of the material damage model or motor controller timing precision. On the other hand, if many repeated and environmentally representative

  5. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  6. The Effects of Repeat Testing, Malingering, and Traumatic Brain Injury on Computerized Measures of Visuospatial Memory Span.

    Science.gov (United States)

    Woods, David L; Wyma, John M; Herron, Timothy J; Yund, E W

    2015-01-01

    Spatial span tests (SSTs) such as the Corsi Block Test (CBT) and the SST of the Wechsler Memory Scale are widely used to assess deficits in spatial working memory. We conducted three experiments to evaluate the test-retest reliability and clinical sensitivity of a new computerized spatial span test (C-SST) that incorporates psychophysical methods to improve the precision of spatial span measurement. In Experiment 1, we analyzed C-SST test-retest reliability in 49 participants who underwent three test sessions at weekly intervals. Intraclass correlation coefficients (ICC) were higher for a psychophysically derived mean span (MnS) metric (0.83) than for the maximal span and total correct metrics used in traditional spatial-span tests. Response times (ReTs) also showed high ICCs (0.93) that correlated negatively with MnS scores and correlated positively with response-time latencies from other tests of processing speed. Learning effects were insignificant. Experiment 2 examined the performance of Experiment 1 participants when instructed to feign symptoms of traumatic brain injury (TBI): 57% showed abnormal MnS z-scores. A MnS z-score cutoff of 3.0 correctly classified 36% of simulated malingerers and 91% of the subgroup of 11 control participants with abnormal spans. Malingerers also made more substitution errors than control participants with abnormal spans (sensitivity = 43%, specificity = 91%). In addition, malingerers showed no evidence of ReT slowing, in contrast to significant abnormalities seen on other malingered tests of processing speed. As a result, differences between ReT z-scores and z-scores on other processing speed tests showed very high sensitivity and specificity in distinguishing malingering and control participants with either normal or abnormal spans. Experiment 3 examined C-SST performance in a group of patients with predominantly mild TBI: neither MnS nor ReT z-scores showed significant group-level abnormalities. The C-SST improves the

  7. Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Edwin Hong-Teck Loh

    2017-08-01

    Full Text Available BackgroundWith increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients.MethodsThis is a retrospective cohort study. Patients with Alzheimer’s disease (AD or mild cognitive impairment (MCI with no change in global clinical dementia rating (CDR score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL and retinal nerve fiber layer (RNFL parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC and coefficients of variation (CoVs.ResultsWe included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948–0.985, and CoV was 1.81% (range: 1.14–2.40; while the average inter-visit ICC was 0.968 (0.941–0.985, and CoV was 1.91% (range: 1.24–2.32. The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937–0.986 and 2.32% (range: 1.34–2.90%, respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845–0.961 and 3.83% (range: 2.71–5.25%, respectively.ConclusionBoth GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time.

  8. A Repeating Fast Radio Burst

    CERN Document Server

    Spitler, L G; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-01-01

    Fast Radio Bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measures (i.e. integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of the fast radio bursts has led several authors to hypothesise that they originate in cataclysmic astrophysical events. Here we report the detection of ten additional bursts from the direction of FRB121102, using the 305-m Arecibo telescope. These new bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and wh...

  9. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  10. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Mirian Ara

    2015-01-01

    Full Text Available Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL thickness parameters measured by scanning laser polarimetry (SLP with enhanced corneal compensation (ECC in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC, coefficient of variation (COV, and test-retest variability (TRT were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT average was the highest (0.967 and 0.946 in normal eyes, while nerve fiber indicator (NFI; 0.982 and inferior average (0.978 yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43% in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  11. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  12. Bayesian hierarchical joint modeling of repeatedly measured continuous and ordinal markers of disease severity: Application to Ugandan diabetes data.

    Science.gov (United States)

    Buhule, O D; Wahed, A S; Youk, A O

    2017-08-22

    Modeling of correlated biomarkers jointly has been shown to improve the efficiency of parameter estimates, leading to better clinical decisions. In this paper, we employ a joint modeling approach to a unique diabetes dataset, where blood glucose (continuous) and urine glucose (ordinal) measures of disease severity for diabetes are known to be correlated. The postulated joint model assumes that the outcomes are from distributions that are in the exponential family and hence modeled as multivariate generalized linear mixed effects model associated through correlated and/or shared random effects. The Markov chain Monte Carlo Bayesian approach is used to approximate posterior distribution and draw inference on the parameters. This proposed methodology provides a flexible framework to account for the hierarchical structure of the highly unbalanced data as well as the association between the 2 outcomes. The results indicate improved efficiency of parameter estimates when blood glucose and urine glucose are modeled jointly. Moreover, the simulation studies show that estimates obtained from the joint model are consistently less biased and more efficient than those in the separate models. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  14. Half-life of the electron-capture decay of 97Ru: Precision measurement shows no temperature dependence

    CERN Document Server

    Goodwin, J R; Iacob, V E; Hardy, J C; 10.1103/PhysRevC.80.045501

    2009-01-01

    We have measured the half-life of the electron-capture (ec) decay of 97Ru in a metallic environment, both at low temperature (19K), and also at room temperature. We find the half-lives at both temperatures to be the same within 0.1%. This demonstrates that a recent claim that the ec decay half-life for 7Be changes by $0.9% +/- 0.2% under similar circumstances certainly cannot be generalized to other ec decays. Our results for the half-life of 97Ru, 2.8370(14)d at room temperature and 2.8382(14)d at 19K, are consistent with, but much more precise than, previous room-temperature measurements. In addition, we have also measured the half-lives of the beta-emitters 103Ru and 105Rh at both temperatures, and found them also to be unchanged.

  15. Repeated-Sprint Cycling Does Not Induce Respiratory Muscle Fatigue in Active Adults: Measurements from The Powerbreathe® Inspiratory Muscle Trainer

    Directory of Open Access Journals (Sweden)

    Clare Minahan, Beth Sheehan, Rachel Doutreband, Tom Kirkwood, Daniel Reeves, Troy Cross

    2015-03-01

    Full Text Available This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., ‘S-Index’ before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p 0.99 and during the Mueller maneuver (p > 0.99. The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults.

  16. Repeatability of measurements of packed cell volume and egg count as indicators of endoparasite load and their relationship with sheep productivity.

    Science.gov (United States)

    Bekele, T; Kasali, O B; Rege, J E

    1991-12-01

    Monthly measurements of packed cell volume (PCV) and nematode and trematode eggs per gram (EPG) were made in Ethiopian highland sheep at Debre Berhan, Dejen, Deneba, Tulu Meko and Wereilu from June 1988 to December 1989. High frequencies of low PCV, high nematode EPG and high trematode EPG were found at Tulu Meko. Among the productivity traits examined, body condition scores and live-weights were significantly (P less than 0.05) associated with differences in PCV and nematode and trematode EPG levels at most sites. The lambing interval was, however, not significantly (P greater than 0.05) affected by these variables. Monthly repeatabilities of PCV, body weight and body condition scores were 0.44 +/- 0.01, 0.71 +/- 0.01 and 0.35 +/- 0.01, respectively, while those of nematode (0.09 +/- 0.01) and trematode EPGs (0.20 +/- 0.02) were much lower. The high repeatability for PCV indicates that it was less affected by the variable factors influencing egg output, and hence it could be utilized in conjunction with nematode and trematode EPG levels for endoparasite monitoring. Repeatability of the lambing interval across parities was 0.43 +/- 0.14.

  17. Relationship between measures of aerobic fitness, speed and repeated sprint ability in full and part time youth soccer players.

    Science.gov (United States)

    Gibson, N; Currie, J; Johnston, R; Hill, J

    2013-02-01

    The aim of the study was to investigate the relationship between repeated sprint ability (RSA) involving changes in direction, short linear sprinting and aerobic capacity in young elite soccer players. A secondary aim was to assess any differences in performance of these assessments between players of different age groups. Thirty-two male adolescent soccer players belonging to the same elite club academy were assessed for RSA comprising 6 x 40m efforts interspersed by 25s recovery, linear sprinting speed over 15m, and aerobic capacity via the YYIE2 assessment. There was a significant correlation between performance in the YYIE2 and RSA total time, RSA fastest sprint and RSA percentage decrement (r = -0.71, -0.53, and -0.52 respectively. Psprint (Psprinting. Assessments of RSA over 40m and incorporating changes of direction appear to be significantly correlated with YYIE2 performance in young elite level soccer players. In addition older players performed significantly better in the YYIE2 assessment and RSA protocol but not in short linear sprinting. These results have implications for the design of assessment protocols for young elite soccer players of different ages.

  18. Very long Detection Times after High and repeated intake of Heroin and Methadone, measured in Oral Fluid

    Directory of Open Access Journals (Sweden)

    Vindenes V.

    2014-12-01

    Full Text Available When detection times for psychoactive drugs in oral fluid are reported, they are most often based on therapeutic doses administered in clinical studies. Repeated ingestions of high doses, as seen after drug abuse, are however likely to cause positive samples for extended time periods. Findings of drugs of abuse in oral fluid might lead to negative sanctions, and the knowledge of detection times of these drugs are important to ensure correct interpretation. The aim of this study was to investigate the detection times of opioids in oral fluid. 25 patients with a history of heavy drug abuse admitted to a detoxification ward were included. Oral fluid and urine were collected daily and, if the patient gave consent, a blood sample was drawn during the first five days after admission. Morphine, codeine and/or 6-monoacetyl morphine (6-MAM were found in oral fluid and/or urine from 20 patients. The maximum detection times in oral fluid for codeine, morphine and 6-MAM were 1, 3 and 8 days, respectively. Positive oral fluid samples were interspersed with negative samples, mainly for concentrations around cut off. Elimination curves for methadone in oral fluid were found for two subjects, and the detection times were 5 and 8 days. Oral fluid is likely to become a good method for detection of drug abuse in the future

  19. Repeatability of peripheral aberrations in young emmetropes.

    Science.gov (United States)

    Baskaran, Karthikeyan; Theagarayan, Baskar; Carius, Staffan; Gustafsson, Jörgen

    2010-10-01

    The purpose of this study is to assess the intrasession repeatability of ocular aberration measurements in the peripheral visual field with a commercially available Shack-Hartmann aberrometer (complete ophthalmic analysis system-high definition-vision research). The higher-order off-axis aberrations data in young healthy emmetropic eyes are also reported. The aberrations of the right eye of 18 emmetropes were measured using an aberrometer with an open field of view that allows peripheral measurements. Five repeated measures of ocular aberrations were obtained and assessed in steps of 10° out to ±40° in the horizontal visual field (nasal + and temporal -) and -20° in the inferior visual field. The coefficient of repeatability, coefficient of variation, and the intraclass correlation coefficient were calculated as a measure of intrasession repeatability. In all eccentric angles, the repeatability of the third- and fourth-order aberrations was better than the fifth and sixth order aberrations. The coefficient of variation was coefficient was >0.90 for the third and fourth order but reduced gradually for higher orders. There was no statistical significant difference in variance of total higher-order root mean square between on- and off-axis measurements (p > 0.05). The aberration data in this group of young emmetropes showed that the horizontal coma (C(3)(1)) was most positive at 40° in the temporal field, decreasing linearly toward negative values with increasing off-axis angle into the nasal field, whereas all other higher-order aberrations showed little or no change. The complete ophthalmic analysis system-high definition-vision research provides fast, repeatable, and valid peripheral aberration measurements and can be used efficiently to measure off-axis aberrations in the peripheral visual field.

  20. Show Time

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    <正> Story: Show Time!The whole class presents the story"Under the Sea".Everyone is so excited and happy.Both Leo and Kathy show their parentsthe characters of the play."Who’s he?"asks Kathy’s mom."He’s the prince."Kathy replies."Who’s she?"asks Leo’s dad."She’s the queen."Leo replieswith a smile.

  1. Snobbish Show

    Institute of Scientific and Technical Information of China (English)

    YIN PUMIN

    2010-01-01

    @@ The State Administration of Radio,Film and Television (SARFT),China's media watchdog,issued a new set of mles on June 9 that strictly regulate TV match-making shows,which have been sweeping the country's primetime programming. "Improper social and love values such as money worship should not be presented in these shows.Humiliation,verbal attacks and sex-implied vulgar content are not allowed" the new roles said.

  2. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  3. Comparison of intraclass correlation coefficient estimates and standard errors between using cross-sectional and repeated measurement data: the Safety Check cluster randomized trial.

    Science.gov (United States)

    Ip, Edward H; Wasserman, Richard; Barkin, Shari

    2011-03-01

    Designing cluster randomized trials in clinical studies often requires accurate estimates of intraclass correlation, which quantifies the strength of correlation between units, such as participants, within a cluster, such as a practice. Published ICC estimates, even when available, often suffer from the problem of wide confidence intervals. Using data from a national, randomized, controlled study concerning violence prevention for children--the Safety Check--we compare the ICC values derived from two approaches only baseline data and using both baseline and follow-up data. Using a variance component decomposition approach, the latter method allows flexibility in handling complex data sets. For example, it allows for shifts in the outcome variable over time and for an unbalanced cluster design. Furthermore, we evaluate the large-sample formula for ICC estimates and standard errors using the bootstrap method. Our findings suggest that ICC estimates range from 0.012 to 0.11 for providers within practice and range from 0.018 to 0.11 for families within provider. The estimates derived from the baseline-only and repeated-measurements approaches agree quite well except in cases in which variation over repeated measurements is large. The reductions in the widths of ICC confidence limits from using repeated measurement over baseline only are, respectively, 62% and 42% at the practice and provider levels. The contribution of this paper therefore includes two elements, which are a methodology for improving the accuracy of ICC, and the reporting of such quantities for pediatric and other researchers who are interested in designing clustered randomized trials similar to the current study.

  4. A Birth Cohort Analysis to Study Dog Walking in Adolescence Shows No Relationship with Objectively Measured Physical Activity

    Directory of Open Access Journals (Sweden)

    Carri Westgarth

    2017-05-01

    Full Text Available Physical inactivity during childhood and adolescence is a serious health concern. There are few studies of the activity undertaken by adolescents when walking with the family dog, and the effect of this on objectively measured physical activity levels. Objective measures of physical activity using accelerometers were recorded at age 11–12, 13–14, and 15–16 years in the Avon Longitudinal Study of Parents and Children (ALSPAC (ALSPAC, UK birth cohort during the 2000s. Family pet ownership was collected retrospectively using a questionnaire at age 18 years, for the ages 7, 11, 13, and 15 years. In addition, approximate frequency per week of walks undertaken with dogs were also reported. Multilevel, multivariable modeling was used to investigate the relationship between dog ownership and dog walking status, and physical activity outcomes. There were a total of 4,373 complete data observations for use in 2,055 children. Reported participation in dog walking tended to increase during adolescence, as did dog ownership. The majority of who own dogs reported walking them either 2–6 times/week (range 39–46% or never (range 27–37%. A small minority (7–8% reported walking their dog every day. Most reported never walking any other dog either (94–87%. We found no evidence for an association between dog ownership or reported dog walking, and objectively measured physical activity (counts per minute, P = 0.3, or minutes of moderate-to-vigorous physical activity, P = 0.7 during adolescence. This study provides no evidence to support a relationship between adolescent dog ownership and physical activity, and demonstrates the importance of using objective activity measures and considering dog walking rather than just dog ownership.

  5. EROBATIC SHOW

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Visitors look at plane models of the Commercial Aircraft Corp. of China, developer of the count,s first homegrown large passenger jet C919, during the Singapore Airshow on February 16. The biennial event is the largest airshow in Asia and one of the most important aviation and defense shows worldwide. A number of Chinese companies took part in the event during which Okay Airways, the first privately owned aidine in China, signed a deal to acquire 12 Boeing 737 jets.

  6. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  7. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  8. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  9. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening

  10. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  11. Measure, Then Show: Grasping Human Evolution Through an Inquiry-Based, Data-driven Hominin Skulls Lab.

    Science.gov (United States)

    Bayer, Chris N; Luberda, Michael

    2016-01-01

    Incomprehension and denial of the theory of evolution among high school students has been observed to also occur when teachers are not equipped to deliver a compelling case also for human evolution based on fossil evidence. This paper assesses the outcomes of a novel inquiry-based paleoanthropology lab teaching human evolution to high-school students. The inquiry-based Be a Paleoanthropologist for a Day lab placed a dozen hominin skulls into the hands of high-school students. Upon measuring three variables of human evolution, students explain what they have observed and discuss findings. In the 2013/14 school year, 11 biology classes in 7 schools in the Greater New Orleans area participated in this lab. The interviewed teacher cohort unanimously agreed that the lab featuring hominin skull replicas and stimulating student inquiry was a pedagogically excellent method of delivering the subject of human evolution. First, the lab's learning path of transforming facts to data, information to knowledge, and knowledge to acceptance empowered students to themselves execute part of the science that underpins our understanding of deep time hominin evolution. Second, although challenging, the hands-on format of the lab was accessible to high-school students, most of whom were readily able to engage the lab's scientific process. Third, the lab's exciting and compelling pedagogy unlocked higher order thinking skills, effectively activating the cognitive, psychomotor and affected learning domains as defined in Bloom's taxonomy. Lastly, the lab afforded students a formative experience with a high degree of retention and epistemic depth. Further study is warranted to gauge the degree of these effects.

  12. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  13. Effects of ambient air pollution on functional status in patients with chronic congestive heart failure: a repeated-measures study

    Directory of Open Access Journals (Sweden)

    Phillips Russell S

    2007-09-01

    Full Text Available Abstract Background Studies using administrative data report a positive association between ambient air pollution and the risk of hospitalization for congestive heart failure (HF. Circulating levels of B-type natriuretic peptide (BNP are directly associated with cardiac hemodynamics and symptom severity in patients with HF and, therefore, serves as a marker of functional status. We tested the hypothesis that BNP levels would be positively associated with short-term changes in ambient pollution levels among 28 patients with chronic stable HF and impaired systolic function. Methods BNP was measured in whole blood at 0, 6, and 12 weeks. We used linear mixed models to evaluate the association between fine particulate matter (PM2.5, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and black carbon and log(BNP. Lags of 0 to 3 days were considered in separate models. We calculated the intraclass correlation coefficient and within-subject coefficient of variation as measures of reproducibility. Results We found no association between any pollutant and measures of BNP at any lag. For example, a 10 μg/m3 increase in PM2.5 was associated with a 0.8% (95% CI: -16.4, 21.5; p = 0.94 increase in BNP on the same day. The within-subject coefficient of variation was 45% on the natural scale and 9% on the log scale. Conclusion These results suggest that serial BNP measurements are unlikely to be useful in a longitudinal study of air pollution-related acute health effects. The magnitude of expected ambient air pollution health effects appears small in relation to the considerable within-person variability in BNP levels in this population.

  14. A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force.

    Science.gov (United States)

    Hall, Rick S; Desmoulin, Geoffrey T; Milner, Theodore E

    2008-12-01

    Miniature sensors that could measure forces applied by the fingers and hand without interfering with manual dexterity or range of motion would have considerable practical value in ergonomics and rehabilitation. In this study, techniques have been developed to use inexpensive pressure-sensing resistors (FSRs) to accurately measure compression force. The FSRs are converted from pressure-sensing to force-sensing devices. The effects of nonlinear response properties and dependence on loading history are compensated by signal conditioning and calibration. A fourth-order polynomial relating the applied force to the current voltage output and a linearly weighted sum of prior outputs corrects for sensor hysteresis and drift. It was found that prolonged (>20h) shear force loading caused sensor gain to change by approximately 100%. Shear loading also had the effect of eliminating shear force effects on sensor output, albeit only in the direction of shear loading. By applying prolonged shear loading in two orthogonal directions, the sensors were converted into pure compression sensors. Such preloading of the sensor is, therefore, required prior to calibration. The error in compression force after prolonged shear loading and calibration was consistently industrial design applications where measurements of finger and hand force are needed.

  15. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25-obese (≥30-....79-0.94) and 0.80 (0.72-0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76-1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62-1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations...

  16. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  17. Repeated-measure validation of craniofacial metrics from three-dimensional surface scans: application to medical genetics

    Science.gov (United States)

    Lauer, Eric A.; Corner, Brian D.; Li, Peng; Beecher, Robert M.; Deutsch, Curtis

    2002-03-01

    Traditionally, medical geneticists have employed visual inspection (anthroposcopy) to clinically evaluate dysmorphology. In the last 20 years, there has been an increasing trend towards quantitative assessment to render diagnosis of anomalies more objective and reliable. These methods have focused on direct anthropometry, using a combination of classical physical anthropology tools and new instruments tailor-made to describe craniofacial morphometry. These methods are painstaking and require that the patient remain still for extended periods of time. Most recently, semiautomated techniques (e.g., structured light scanning) have been developed to capture the geometry of the face in a matter of seconds. In this paper, we establish that direct anthropometry and structured light scanning yield reliable measurements, with remarkably high levels of inter-rater and intra-rater reliability, as well as validity (contrasting the two methods).

  18. NEIGHBOURHOOD POVERTY, PERCEIVED DISCRIMINATION AND CENTRAL ADIPOSITY IN THE USA: INDEPENDENT ASSOCIATIONS IN A REPEATED MEASURES ANALYSIS.

    Science.gov (United States)

    Kwarteng, Jamila L; Schulz, Amy J; Mentz, Graciela B; Israel, Barbara A; Shanks, Trina R; Perkins, Denise White

    2016-11-01

    This study examines the independent effects of neighbourhood context (i.e. neighbourhood poverty) and exposure to perceived discrimination in shaping risk of obesity over time. Weighted three-level hierarchical linear regression models for a continuous outcome were used to assess the independent effects of neighbourhood poverty and perceived discrimination on obesity over time in a sample of 157 non-Hispanic Black, non-Hispanic White and Hispanic adults in Detroit, USA, in 2002/2003 and 2007/2008. Independent associations were found between neighbourhood poverty and perceived discrimination with central adiposity over time. Residents of neighbourhoods with high concentrations of poverty were more likely to show increases in central adiposity compared with those in neighbourhoods with lower concentrations of poverty. In models adjusted for BMI, neighbourhood poverty at baseline was associated with a greater change in central adiposity among participants who lived in neighbourhoods in the second (B=3.79, p=0.025) and third (B=3.73, p=0.024) poverty quartiles, compared with those in the lowest poverty neighbourhoods. The results from models that included both neighbourhood poverty and perceived discrimination showed that both were associated with increased risk of increased central adiposity over time. Residents of neighbourhoods in the second (B=9.58, p<0.001), third (B=8.25, p=0.004) and fourth (B=7.66, p=0.030) quartiles of poverty were more likely to show greater increases in central adiposity over time, compared with those in the lowest poverty quartile, with mean discrimination at baseline independently and positively associated with increases in central adiposity over time (B=2.36, p=0.020). The results suggest that neighbourhood poverty and perceived discrimination are independently associated with a heightened risk of increase in central adiposity over time. Efforts to address persistent disparities in central adiposity in the USA should include strategies to

  19. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  20. Evaluation of Multiple Imputation in Missing Data Analysis: An Application on Repeated Measurement Data in Animal Science

    Directory of Open Access Journals (Sweden)

    Gazel Ser

    2015-12-01

    Full Text Available The purpose of this study was to evaluate the performance of multiple imputation method in case that missing observation structure is at random and completely at random from the approach of general linear mixed model. The application data of study was consisted of a total 77 heads of Norduz ram lambs at 7 months of age. After slaughtering, pH values measured at five different time points were determined as dependent variable. In addition, hot carcass weight, muscle glycogen level and fasting durations were included as independent variables in the model. In the dependent variable without missing observation, two missing observation structures including Missing Completely at Random (MCAR and Missing at Random (MAR were created by deleting the observations at certain rations (10% and 25%. After that, in data sets that have missing observation structure, complete data sets were obtained using MI (multiple imputation. The results obtained by applying general linear mixed model to the data sets that were completed using MI method were compared to the results regarding complete data. In the mixed model which was applied to the complete data and MI data sets, results whose covariance structures were the same and parameter estimations and standard estimations were rather close to the complete data are obtained. As a result, in this study, it was ensured that reliable information was obtained in mixed model in case of choosing MI as imputation method in missing observation structure and rates of both cases.

  1. Repeated electromagnetic induction measurements for mapping soil moisture at the field scale: comparison with data from a wireless soil moisture monitoring network

    Science.gov (United States)

    Martini, Edoardo; Werban, Ulrike; Zacharias, Steffen; Pohle, Marco; Dietrich, Peter; Wollschläger, Ute

    2016-04-01

    Electromagnetic induction (EMI) methods are widely used for soil mapping, as they allow fast and relatively low-cost surveys of soil apparent electrical conductivity (ECa) at various scales. Soil ECa is well known to be influenced by both the volumetric content and the electrical conductivity (EC) of soil water, as well as by soil temperature and by the volume of the solid particles and their EC. Among other applications, EMI has become widely used to determine soil water content or to study hydrological processes within the field of hydrogeophysics. Although the use of non-invasive EMI for imaging soil spatial properties is very attractive, the dependence of ECa on several properties and states challenges any interpretation with respect to individual soil properties or states such as θ. The major aim of this study was to further investigate the potential of repeated EMI measurements to map soil moisture at the hillslope scale, with particular focus on the temporal variability of the spatial patterns of ECa and soil moisture, respectively, and on the stability of the ECa-soil moisture relationship over time. To this end, we compared time series of EMI measurements with high-resolution soil moisture data for a non-intensively managed hillslope area in the Schäfertal catchment (Central Germany) for which the spatial distribution of soil properties and soil water dynamics were known in detail. Soil water and temperature dynamics were observed in 40 soil profiles at hourly resolution during 14 months using a wireless monitoring network. During this period of time, ECa was mapped on seven occasions using an EM38-DD device. For the investigated site, ECa showed small temporal variations (ranging between 0 and 24 mS/m) whereas the temporal range of soil moisture was very large (from very dry to soil saturation). Furthermore, temporal changes of the spatial pattern of ECa differed from temporal changes of the spatial pattern of soil moisture. The ECa-soil moisture

  2. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  3. Measurement of the half-life of 198Au in a non-metal: High-precision measurement shows no host-material dependence

    CERN Document Server

    Goodwin, J R; Iacob, V E; Dibidad, A; Hardy, J C

    2010-01-01

    We have measured the half-life of the beta decay of 198Au to be 2.6948(9) d, with the nuclide sited in an insulating environment. Comparing this result with the half-life we measured previously with a metallic environment, we find the half-lives in both environments to be the same within 0.04%, thus contradicting a prediction that screening from a "plasma" of quasi-free electrons in a metal increases the half-life by as much as 7%.

  4. An integrated approach to biomonitoring exposure to styrene and styrene-(7,8)-oxide using a repeated measurements sampling design.

    Science.gov (United States)

    Fustinoni, S; Campo, L; Manini, P; Buratti, M; Waidyanatha, S; De Palma, G; Mutti, A; Foa, V; Colombi, A; Rappaport, S M

    2008-09-01

    The aim of this work was to investigate urinary analytes and haemoglobin and albumin adducts as biomarkers of exposure to airborne styrene (Sty) and styrene-(7,8)-oxide (StyOX) and to evaluate the influence of smoking habit and genetic polymorphism of metabolic enzymes GSTM1 and GSTT1 on these biomarkers. We obtained three or four air and urine samples from each exposed worker (eight reinforced plastics workers and 13 varnish workers), one air and urine samples from 22 control workers (automobile mechanics) and one blood sample from all subjects. Median levels of exposure to Sty and StyOX, respectively, were 18.2 mg m(-3) and 133 microg m(-3) for reinforced plastics workers, 3.4 mg m(-3) and 12 microg m(-3) for varnish workers, and <0.3 mg m(-3) and <5 microg m(-3) for controls. Urinary levels of styrene, mandelic acid, phenylglyoxylic acid, phenylglycine (PHG), 4-vinylphenol (VP) and mercapturic acids (M1+M2), as well as cysteinyl adducts of serum albumin (but not those of haemoglobin) were significantly associated with exposure status (controlsshowed that Sty was a significant predictor for all urinary analytes while StyOX was a significant predictor of PHG only. Interestingly, the log scale regression coefficients for Sty in these models were significantly less than one for all metabolites except M1+M2. This suggests that the natural scale relationships between levels of all Sty metabolites, except M1+M2, displayed downward concavity with increasing Sty exposure, suggestive of saturable metabolism. Levels of the protein adducts were not associated with exposure to either Sty or StyOX among exposed subjects.

  5. Repeatability Evaluation of Finger Tapping Device with Magnetic Sensors

    Science.gov (United States)

    Sano, Yuko; Kandori, Akihiko; Shima, Keisuke; Tamura, Yasuhiro; Takagi, Hiroshi; Tsuji, Toshio; Noda, Masafumi; Higashikawa, Fumiko; Yokoe, Masaru; Sakoda, Saburo

    We tested the repeatability of a finger tapping device with magnetic sensors to determine its reliability. This device, which was developed to assist in the diagnosis of movement disorders such as Parkinson's disease (PD) and strokes, measures the distance between the first and index fingers during finger tapping movements (opening and closing the fingers repeatedly). We evaluated three types of repeatability based on ICC (interclass correlation coefficient) and Welch's test (test for equal means in a oneway layout): repeatability when measured at different times, when using different devices, and when using different measurers. We calculated these three types for three finger tapping tasks on both hands for 21 characteristics calculated from finger tapping waveforms. Results demonstrated that the repeatability when using different devices is high regardless of the task or hand. The repeatability when measuring at different times and when using different measurers is high at some tasks, but not all. One of the finger tapping tasks (finger tapping movement with the largest amplitude and highest velocity), which is used in a conventional PD diagnosis method (UPDRS), does not have enough repeatability, while other tasks show high repeatability. Results also showed that five characteristics have the highest repeatability (ICC ≥ 0.5 or significance probability of Welch's test ≥ 5% in all tasks): “total moving distance,” “average of local minimum acceleration in opening motion,” “average of local minimum acceleration in closing motion,” “average of local maximum distance” and “average of local minimum velocity”. These results clearly demonstrate the strong repeatability of this device and lead to more precise diagnosis of movement disorders.

  6. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  7. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2017-09-04

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  8. Automated genotyping of dinucleotide repeat markers

    Energy Technology Data Exchange (ETDEWEB)

    Perlin, M.W.; Hoffman, E.P. [Carnegie Mellon Univ., Pittsburgh, PA (United States)]|[Univ. of Pittsburgh, PA (United States)

    1994-09-01

    The dinucleotide repeats (i.e., microsatellites) such as CA-repeats are a highly polymorphic, highly abundant class of PCR-amplifiable markers that have greatly streamlined genetic mapping experimentation. It is expected that over 30,000 such markers (including tri- and tetranucleotide repeats) will be characterized for routine use in the next few years. Since only size determination, and not sequencing, is required to determine alleles, in principle, dinucleotide repeat genotyping is easily performed on electrophoretic gels, and can be automated using DNA sequencers. Unfortunately, PCR stuttering with these markers generates not one band for each allele, but a pattern of bands. Since closely spaced alleles must be disambiguated by human scoring, this poses a key obstacle to full automation. We have developed methods that overcome this obstacle. Our model is that the observed data is generated by arithmetic superposition (i.e., convolution) of multiple allele patterns. By quantitatively measuring the size of each component band, and exploiting the unique stutter pattern associated with each marker, closely spaced alleles can be deconvolved; this unambiguously reconstructs the {open_quotes}true{close_quotes} allele bands, with stutter artifact removed. We used this approach in a system for automated diagnosis of (X-linked) Duchenne muscular dystrophy; four multiplexed CA-repeats within the dystrophin gene were assayed on a DNA sequencer. Our method accurately detected small variations in gel migration that shifted the allele size estimate. In 167 nonmutated alleles, 89% (149/167) showed no size variation, 9% (15/167) showed 1 bp variation, and 2% (3/167) showed 2 bp variation. We are currently developing a library of dinucleotide repeat patterns; together with our deconvolution methods, this library will enable fully automated genotyping of dinucleotide repeats from sizing data.

  9. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  10. Lumbar spine and pelvic posture between standing and sitting: a radiologic investigation including reliability and repeatability of the lumbar lordosis measure.

    Science.gov (United States)

    De Carvalho, Diana E; Soave, David; Ross, Kim; Callaghan, Jack P

    2010-01-01

    Sitting has been identified as a cause of mechanical low back pain. The purpose of this study was to use plain film x-rays to measure lumbar spine and pelvic posture differences between standing and sitting. Eight male subjects were radiographed standing and sitting in an automobile seat. Measures of lumbar lordosis, intervertebral disk angles, lumbosacral angle, lumbosacral lordosis, and sacral tilt were completed. One-way analysis of variance (alpha = .05) was conducted on the variables stated above. A Bland-Altman analysis was conducted to assess agreement and repeatability of the lumbar lordosis angle using 2 raters. Lumbar lordosis values in standing (average, 63 degrees +/- 15 degrees ) and sacral inclination (average, 43 degrees +/- 10 degrees ) decreased by 43 degrees and 44 degrees , respectively, in sitting. Intervertebral joint angles in sitting underwent substantial flexion (L1/L2-5 degrees [+/-3 degrees ], L2/L3-7 degrees [+/-3 degrees ], L3/L4-8 degrees [+/-3 degrees ], L4/L5-13 degrees [+/-3 degrees ], and L5/S1-4 degrees [+/-10 degrees ]). Measures of lumbar lordosis; intervertebral disk angles between L2/L3, L3/L4, and L4/L5; lumbosacral lordosis; lumbosacral angle; and sacral tilt were significantly decreased between standing and sitting (P posture should be investigated because they may play a role in preventing injury and low back pain. Copyright 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  11. Who Repeats Algebra, and How Does Initial Performance Relate to Improvement When the Course Is Repeated?

    Science.gov (United States)

    Fong, Anthony; Jaquet, Karina; Finkelstein, Neal

    2016-01-01

    The information provided in this report shows how students perform when they repeat algebra I and how the level of improvement varies depending on initial course performance and the academic measure (course grades or CST scores). This information can help inform decisions and policies regarding whether and under what circumstances students should…

  12. 基于同频RF直放站的回波测量方法%Technique of measuring the echo for RF repeaters in single frequency networks

    Institute of Scientific and Technical Information of China (English)

    陈哲; 宋葛

    2011-01-01

    直放站的同频转发模式存在收发天线间互耦的问题,接收天线在接收主基站的信号时,同时接收到直放站发射天线发射的信号,以同频RF直放站调试隔离度为技术背景,提出了同频RF直放站的回波测量方法.该方法利用CAZAC码实现的初估计快速地估计出回波信道的特性,自适应LMS算法的使用可以进一步跟踪信道的变化.通过MATLAB仿真后,在数字硬件平台上用FPGA实现该方法,并用数字电视信号CMMB做为信号源对系统进行了测试,结果说明此种测量方法准确、实用.%The signal transition mode of repeater which works on the same frequency has some troubles on signal coupling between receive and transmit aerials,the signal from transmit aerial may leak out into receive aerial. This paper presents a method of measuring the echo under the context of isolation test for RF repeaters in single frequency networks. The experimental apparatus firstly uses CAZAC code as the method of channel initial estimation, secondly uses LMS arithmetic to track the change of the channel. After the MATLAB simulation realization has been achieved by FPGA on real digital hardware board. The result of test which uses DTV signal (CMMB) as the source proves the function of method achieved accurately.

  13. Repeat, Low Altitude Measurements of Vegetation Status and Biomass Using Manned Aerial and UAS Imagery in a Piñon-Juniper Woodland

    Science.gov (United States)

    Krofcheck, D. J.; Lippitt, C.; Loerch, A.; Litvak, M. E.

    2015-12-01

    Measuring the above ground biomass of vegetation is a critical component of any ecological monitoring campaign. Traditionally, biomass of vegetation was measured with allometric-based approach. However, it is also time-consuming, labor-intensive, and extremely expensive to conduct over large scales and consequently is cost-prohibitive at the landscape scale. Furthermore, in semi-arid ecosystems characterized by vegetation with inconsistent growth morphologies (e.g., piñon-juniper woodlands), even ground-based conventional allometric approaches are often challenging to execute consistently across individuals and through time, increasing the difficulty of the required measurements and consequently the accuracy of the resulting products. To constrain the uncertainty associated with these campaigns, and to expand the extent of our measurement capability, we made repeat measurements of vegetation biomass in a semi-arid piñon-juniper woodland using structure-from-motion (SfM) techniques. We used high-spatial resolution overlapping aerial images and high-accuracy ground control points collected from both manned aircraft and multi-rotor UAS platforms, to generate digital surface model (DSM) for our experimental region. We extracted high-precision canopy volumes from the DSM and compared these to the vegetation allometric data, s to generate high precision canopy volume models. We used these models to predict the drivers of allometric equations for Pinus edulis and Juniperous monosperma (canopy height, diameter at breast height, and root collar diameter). Using this approach, we successfully accounted for the carbon stocks in standing live and standing dead vegetation across a 9 ha region, which contained 12.6 Mg / ha of standing dead biomass, with good agreement to our field plots. Here we present the initial results from an object oriented workflow which aims to automate the biomass estimation process of tree crown delineation and volume calculation, and partition

  14. Repetibilidade e número mínimo de medições para caracteres de cacho de bacabi (Oenocarpus mapora Repeatability and minimum number of measurements for characters of bacabi palm (Oenocarpus mapora racemes

    Directory of Open Access Journals (Sweden)

    Maria do Socorro Padilha de Oliveira

    2010-12-01

    potential for commercial and food uses, but has not been well studied. The objectives of this study were to estimate the repeatability coefficients, determine predictability and the number of measurements needed for raceme characters of this palm. 27 individuals of bacabi that belong to the Germplasm Bank of Oenocarpus/Jessenia at Embrapa Eastern Amazon, in Belém, PA, Brazil were evaluated. Three fully matured racemes from each plant were sampled to measure six characters: total weight of raceme (TWR and fruit weight per raceme (FWR, number of rachillae per raceme (NRR, rachis length per raceme (RLR, weight of 100 fruits (WHF and fruit yield per raceme (FER. The repeatability estimates were obtained by three statistical methods: analysis of variance; principal components; and structural analysis. For all characters, the estimates of repeatability coefficients presented values with very similar magnitudes in the three methods. The estimates of repeatability coefficients and determination coefficients were relatively high (r 0.60 and R2 81.7% for the characters FER and NRR, showing genotype regularity for these raceme measurements. For these characters, the minimum number of racemes necessary to estimate the true character value of the genotypes was thirteen (FER and five (NRR, with 95% reliability. The remaining characters showed repeatabilities and determination coefficients with medium to low values, indicating the need for better environmental control to make the measurements.

  15. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim;

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...

  16. Evaluation of the running-based anaerobic sprint test as a measure of repeated sprint ability in collegiate-level soccer players.

    Science.gov (United States)

    Keir, Daniel A; Thériault, Francis; Serresse, Olivier

    2013-06-01

    Repeated sprint ability (RSA) refers to an individual's ability to perform maximal sprints of short duration in succession with little recovery between sprints. The running-based anaerobic sprint test (RAST) has been adapted from the Wingate anaerobic test (WAnT) protocol as a tool to assess RSA and anaerobic power. The purpose of this study was to evaluate the relationship between performance variables and physiological responses obtained during the RAST and the WAnT using 8 collegiate-level soccer players. Participants performed a single trial of both the WAnT and the RAST. Breath-by-breath gas exchange was monitored throughout each trial, and blood lactate (BL) measures were recorded postexercise. The oxygen uptake (VO2) profile suggested that the RAST required greater contributions from aerobic metabolism although there was no difference in VO2peak (p < 0.05). Peak BL values were also similar between the RAST and the WAnT (p < 0.05). Neither peak physiological values nor performance variables (peak and mean power) were significantly correlated between protocols. The weak association in physiological responses indicates that different combinations of metabolic contributions exist between protocols, suggesting that individual performances on each test are not related in collegiate soccer players. Further studies on these relationships with players of other competitive levels and team sport athletes are warranted.

  17. Knowledge and skill retention of in-service versus preservice nursing professionals following an informal training program in pediatric cardiopulmonary resuscitation: a repeated-measures quasiexperimental study.

    Science.gov (United States)

    Sankar, Jhuma; Vijayakanthi, Nandini; Sankar, M Jeeva; Dubey, Nandkishore

    2013-01-01

    Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR) on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses) and final year undergraduate nursing students (preservice nurses) using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants-28 in-service and 46 preservice professionals-were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P = 0.08) while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P nurses performing better in knowledge test (10.5 versus 9.1, P = 0.01) and the preservice nurses performing better in skill test (9.8 versus 7.4, P skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  18. Direct and accurate measurement of CAG repeat configuration in the ataxin-1 (ATXN-1) gene by "dual-fluorescence labeled PCR-restriction fragment length analysis".

    Science.gov (United States)

    Lin, Jiang X; Ishikawa, Kinya; Sakamoto, Masaki; Tsunemi, Taiji; Ishiguro, Taro; Amino, Takeshi; Toru, Shuta; Kondo, Ikuko; Mizusawa, Hidehiro

    2008-01-01

    Spinocerebellar ataxia type 1 (SCA1; OMIM: #164400) is an autosomal dominant cerebellar ataxia caused by an expansion of CAG repeat, which encodes polyglutamine, in the ataxin-1 (ATXN1) gene. Length of polyglutamine in the ATXN1 protein is the critical determinant of pathogenesis of this disease. Molecular diagnosis of SCA1 is usually undertaken by assessing the length of CAG repeat configuration using primers spanning this configuration. However, this conventional method may potentially lead to misdiagnosis in assessing polyglutamine-encoding CAG repeat length, since CAT interruptions may be present within the CAG repeat configuration, not only in normal controls but also in neurologically symptomatic subjects. We developed a new method for assessing actual CAG repeat numbers not interrupted by CAT sequences. Polymerase chain reaction using a primer pair labeled with two different fluorescences followed by restriction enzyme digestion with SfaNI which recognizes the sequence "GCATC(N)(5)", lengths of actual CAG repeats that encode polyglutamine were directly detected. We named this method "dual fluorescence labeled PCR-restriction fragment length analysis". We found that numbers of actual CAG repeat encoding polyglutamine do not overlap between our cohorts of normal chromosomes (n=385) and SCA1 chromosomes (n=5). We conclude that the present method is a useful way for molecular diagnosis of SCA1.

  19. Simulated Conversations With Virtual Humans to Improve Patient-Provider Communication and Reduce Unnecessary Prescriptions for Antibiotics: A Repeated Measure Pilot Study

    Science.gov (United States)

    2017-01-01

    Background Despite clear evidence that antibiotics do not cure viral infections, the problem of unnecessary prescribing of antibiotics in ambulatory care persists, and in some cases, prescribing patterns have increased. The overuse of antibiotics for treating viral infections has created numerous economic and clinical consequences including increased medical costs due to unnecessary hospitalizations, antibiotic resistance, disruption of gut bacteria, and obesity. Recent research has underscored the importance of collaborative patient-provider communication as a means to reduce the high rates of unnecessary prescriptions for antibiotics. However, most patients and providers do not feel prepared to engage in such challenging conversations. Objectives The aim of this pilot study was to assess the ability of a brief 15-min simulated role-play conversation with virtual humans to serve as a preliminary step to help health care providers and patients practice, and learn how to engage in effective conversations about antibiotics overuse. Methods A total of 69 participants (35 providers and 34 patients) completed the simulation once in one sitting. A pre-post repeated measures design was used to assess changes in patients’ and providers’ self-reported communication behaviors, activation, and preparedness, intention, and confidence to effectively communicate in the patient-provider encounter. Changes in patients’ knowledge and beliefs regarding antibiotic use were also evaluated. Results Patients experienced a short-term positive improvement in beliefs about appropriate antibiotic use for infection (F1,30=14.10, P=.001). Knowledge scores regarding the correct uses of antibiotics improved immediately postsimulation, but decreased at the 1-month follow-up (F1,30=31.16, P.10) Patients with lower levels of activation exhibited positive, short-term benefits in increased intent and confidence to discuss their needs and ask questions in the clinic visit, positive attitudes

  20. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  1. Joint modeling of repeated multivariate cognitive measures and competing risks of dementia and death: a latent process and latent class approach.

    Science.gov (United States)

    Proust-Lima, Cécile; Dartigues, Jean-François; Jacqmin-Gadda, Hélène

    2016-02-10

    Joint models initially dedicated to a single longitudinal marker and a single time-to-event need to be extended to account for the rich longitudinal data of cohort studies. Multiple causes of clinical progression are indeed usually observed, and multiple longitudinal markers are collected when the true latent trait of interest is hard to capture (e.g., quality of life, functional dependency, and cognitive level). These multivariate and longitudinal data also usually have nonstandard distributions (discrete, asymmetric, bounded, etc.). We propose a joint model based on a latent process and latent classes to analyze simultaneously such multiple longitudinal markers of different natures, and multiple causes of progression. A latent process model describes the latent trait of interest and links it to the observed longitudinal outcomes using flexible measurement models adapted to different types of data, and a latent class structure links the longitudinal and cause-specific survival models. The joint model is estimated in the maximum likelihood framework. A score test is developed to evaluate the assumption of conditional independence of the longitudinal markers and each cause of progression given the latent classes. In addition, individual dynamic cumulative incidences of each cause of progression based on the repeated marker data are derived. The methodology is validated in a simulation study and applied on real data about cognitive aging obtained from a large population-based study. The aim is to predict the risk of dementia by accounting for the competing death according to the profiles of semantic memory measured by two asymmetric psychometric tests.

  2. Origin and fate of repeats in bacteria.

    Science.gov (United States)

    Achaz, G; Rocha, E P C; Netter, P; Coissac, E

    2002-07-01

    We investigated 53 complete bacterial chromosomes for intrachromosomal repeats. In previous studies on eukaryote chromosomes, we proposed a model for the dynamics of repeats based on the continuous genesis of tandem repeats, followed by an active process of high deletion rate, counteracted by rearrangement events that may prevent the repeats from being deleted. The present study of long repeats in the genomes of Bacteria and Archaea suggests that our model of interspersed repeats dynamics may apply to them. Thus the duplication process might be a consequence of very ancient mechanisms shared by all three domains. Moreover, we show that there is a strong negative correlation between nucleotide composition bias and the repeat density of genomes. We hypothesise that in highly biased genomes, non-duplicated small repeats arise more frequently by random effects and are used as primers for duplication mechanisms, leading to a higher density of large repeats.

  3. An evaluation of a structured learning program as a component of the clinical practicum in undergraduate nurse education: A repeated measures analysis.

    Science.gov (United States)

    Watt, Elizabeth; Murphy, Maria; MacDonald, Lee; Pascoe, Elizabeth; Storen, Heather; Scanlon, Andrew

    2016-01-01

    There is evidence that nursing students experience stress and anxiety and a reduction in self-efficacy when undertaking clinical placements. Previous reports have identified that a structured three-day program within the Bachelor of Nursing (BN) clinical practicum reduces the students self-report of anxiety and increases self-efficacy. However, it is unreported whether these improved outcomes are sustained for the duration of the clinical placement. The aim of this study was to evaluate the duration of the effect of a three-day structured learning program within the clinical placement on final year Bachelor of Nursing student's report of anxiety and self-efficacy pre- and post-program participation in this intervention and following completion of the clinical practicum. A repeated measures design. University-based Clinical School of Nursing, acute care clinical practicum. Final year Bachelor of Nursing students. The intervention comprised the three-day program on starting the clinical practicum. A questionnaire included the anxiety subscale of The Hospital Anxiety & Depression Scale (The HAD) and the General Self-Efficacy Scale (GSES-12). The questionnaire was completed on day one (time one), upon completion of the three-day program (time two) and upon completion of placement on day 18 (time three). The questionnaire response rate varied over time. There was a statistically significant effect in reducing anxiety over time: F(1.73,74.46)=25.20, plearning program and the benefit of the intervention is sustained for the clinical placement duration. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Which are the most useful scales for predicting repeat self-harm? A systematic review evaluating risk scales using measures of diagnostic accuracy

    Science.gov (United States)

    Quinlivan, L; Cooper, J; Davies, L; Hawton, K; Gunnell, D; Kapur, N

    2016-01-01

    Objectives The aims of this review were to calculate the diagnostic accuracy statistics of risk scales following self-harm and consider which might be the most useful scales in clinical practice. Design Systematic review. Methods We based our search terms on those used in the systematic reviews carried out for the National Institute for Health and Care Excellence self-harm guidelines (2012) and evidence update (2013), and updated the searches through to February 2015 (CINAHL, EMBASE, MEDLINE, and PsychINFO). Methodological quality was assessed and three reviewers extracted data independently. We limited our analysis to cohort studies in adults using the outcome of repeat self-harm or attempted suicide. We calculated diagnostic accuracy statistics including measures of global accuracy. Statistical pooling was not possible due to heterogeneity. Results The eight papers included in the final analysis varied widely according to methodological quality and the content of scales employed. Overall, sensitivity of scales ranged from 6% (95% CI 5% to 6%) to 97% (CI 95% 94% to 98%). The positive predictive value (PPV) ranged from 5% (95% CI 3% to 9%) to 84% (95% CI 80% to 87%). The diagnostic OR ranged from 1.01 (95% CI 0.434 to 2.5) to 16.3 (95%CI 12.5 to 21.4). Scales with high sensitivity tended to have low PPVs. Conclusions It is difficult to be certain which, if any, are the most useful scales for self-harm risk assessment. No scales perform sufficiently well so as to be recommended for routine clinical use. Further robust prospective studies are warranted to evaluate risk scales following an episode of self-harm. Diagnostic accuracy statistics should be considered in relation to the specific service needs, and scales should only be used as an adjunct to assessment. PMID:26873046

  5. Detection of the effects of repeated dose combined propoxur and heavy metal exposure by measurement of certain toxicological, haematological and immune function parameters in rats.

    Science.gov (United States)

    Institóris, L; Siroki, O; Undeger, U; Basaran, N; Banerjee, B D; Dési, I

    2001-06-21

    In the present study, an immunotoxicity test system, containing general toxicological (body weight gain, organ weights), haematological (WBC,RBC, Ht, mean cell volume of the RBCs, cell content of the femoral bone marrow), and immune function (PFC assay, DTH reaction) investigations, was used for detection the effects of a 4 weeks repeated low dose combined oral exposure of male Wistar rats with propoxur and the heavy metals arsenic or mercury. Two doses of the compounds were used: a higher one (the lowest dose which resulted in significant change of at least one parameter examined in previous dose-effect experiments), and a lower one (the highest dose which proved to be non-effective). The applied doses were: 8.51 and 0.851 mg kg(-1) of propoxur, 13.3 and 3.33 mg kg(-1) of NaAsO(2), and 3.20 and 0.40 mg kg(-1) of HgCl(2). In the combination treatment, the high dose of propoxur was combined with the low dose of arsenic or mercury, and the high doses of each heavy metals were combined with the low dose of propoxur. The main finding of this study was that some of the combinations significantly altered the relative weight of liver, adrenals and kidneys, related to both the untreated and the high dose internal control. Among the immune functions examined, only the PFC content of the spleen showed a trend of changes in certain combinations versus the corresponding high dose control. According to the present results, combined exposure with propoxur and the heavy metals examined can modify the detection limit of the single compounds and/or may alter their toxic effects.

  6. Associations between inverted repeats and the structural evolution of bacterial genomes.

    Science.gov (United States)

    Achaz, Guillaume; Coissac, Eric; Netter, Pierre; Rocha, Eduardo P C

    2003-08-01

    The stability of the structure of bacterial genomes is challenged by recombination events. Since major rearrangements (i.e., inversions) are thought to frequently operate by homologous recombination between inverted repeats, we analyzed the presence and distribution of such repeats in bacterial genomes and their relation to the conservation of chromosomal structure. First, we show that there is a strong under-representation of inverted repeats, relative to direct repeats, in most chromosomes, especially among the ones regarded as most stable. Second, we show that the avoidance of repeats is frequently associated with the stability of the genomes. Closely related genomes reported to differ in terms of stability are also found to differ in the number of inverted repeats. Third, when using replication strand bias as a proxy for genome stability, we find a significant negative correlation between this strand bias and the abundance of inverted repeats. Fourth, when measuring the recombining potential of inverted repeats and their eventual impact on different features of the chromosomal structure, we observe a tendency of repeats to be located in the chromosome in such a way that rearrangements produce a smaller strand switch and smaller asymmetries than expected by chance. Finally, we discuss the limitations of our analysis and the influence of factors such as the nature of repeats, e.g., transposases, or the differences in the recombination machinery among bacteria. These results shed light on the challenges imposed on the genome structure by the presence of inverted repeats.

  7. Association of Repeatedly Measured High-Sensitivity-Assayed Troponin I with Cardiovascular Disease Events in a General Population from the MORGAM/BiomarCaRE Study

    DEFF Research Database (Denmark)

    Hughes, Maria F; Ojeda, Francisco; Saarela, Olli;

    2017-01-01

    BACKGROUND: High-sensitivity troponin I (hs-cTnI) concentrations reflect myocardial stress. The role of hs-cTnI in predicting long-term changes in the risk of cardiovascular disease (CVD) in general populations is not clearly defined. METHODS: We investigated whether the change in 3 repeated meas...

  8. Fluorescence measurements show stronger cold inhibition of photosynthetic light reactions in Scots pine compared to Norway spruce as well as during spring compared to autumn.

    Science.gov (United States)

    Linkosalo, Tapio; Heikkinen, Juha; Pulkkinen, Pertti; Mäkipää, Raisa

    2014-01-01

    We studied the photosynthetic activity of Scots pine (Pinus sylvestris L.) and Norway spruce (Picea abies [L.] Karst) in relation to air temperature changes from March 2013 to February 2014. We measured the chlorophyll fluorescence of approximately 50 trees of each species growing in southern Finland. Fluorescence was measured 1-3 times per week. We began by measuring shoots present in late winter (i.e., March 2013) before including new shoots once they started to elongate in spring. By July, when the spring shoots had achieved similar fluorescence levels to the older ones, we proceeded to measure the new shoots only. We analyzed the data by fitting a sigmoidal model containing four parameters to link sliding averages of temperature and fluorescence. A parameter defining the temperature range over which predicted fluorescence increased most rapidly was the most informative with in describing temperature dependence of fluorescence. The model generated similar fluorescence patterns for both species, but differences were observed for critical temperature and needle age. Down regulation of the light reaction was stronger in spring than in autumn. Pine showed more conservative control of the photosynthetic light reactions, which were activated later in spring and more readily attenuated in autumn. Under the assumption of a close correlation of fluorescence and photosynthesis, spruce should therefore benefit more than pine from the increased photosynthetic potential during warmer springs, but be more likely to suffer frost damage with a sudden cooling following a warm period. The winter of 2013-2014 was unusually mild and similar to future conditions predicted by global climate models. During the mild winter, the activity of photosynthetic light reactions of both conifers, especially spruce, remained high. Because light levels during winter are too low for photosynthesis, this activity may translate to a net carbon loss due to respiration.

  9. Fluorescence measurements show stronger cold inhibition of photosynthetic light reactions in Scots pine compared to Norway spruce as well as during spring compared to autumn

    Directory of Open Access Journals (Sweden)

    Tapio eLinkosalo

    2014-06-01

    Full Text Available We studied the photosynthetic activity of Scots pine (Pinus sylvestris L. and Norway spruce (Picea abies [L.] Karst in relation to air temperature changes from March 2013 to February 2014. We measured the chlorophyll fluorescence of approximately 50 trees of each species growing in southern Finland. Fluorescence was measured 13 times per week. We began by measuring shoots present in late winter (i.e., March 2013 before including new shoots once they started to elongate in spring. By July, when the spring shoots had achieved similar fluorescence levels to the older ones, we proceeded to measure the new shoots only.We analysed the data by fitting a sigmoidal model containing four parameters to link sliding averages of temperature and fluorescence. A parameter defining the temperature range over which predicted fluorescence increased most rapidly was the most informative with in describing temperature dependence of fluorescence.The model generated similar fluorescence patterns for both species, but differences were observed for critical temperature and needle age. Down regulation of the light reaction was stronger in spring than in autumn. Pine showed more conservative control of the photosynthetic light reactions, which were activated later in spring and more readily attenuated in autumn. Under the assumption of a close correlation of fluorescence and photosynthesis, spruce should therefore benefit more than pine from the increased photosynthetic potential during warmer springs, but be more likely to suffer frost damage with a sudden cooling following a warm period. The winter of 20132014 was unusually mild and similar to future conditions predicted by global warming models. During the mild winter, the activity of photosynthetic light reactions of both conifers, especially spruce, remained high. Because light levels during winter are too low for photosynthesis, this activity may translate to a net carbon loss due to respiration.

  10. Quantum repeaters with entangled coherent states

    CERN Document Server

    Sangouard, Nicolas; Gisin, Nicolas; Laurat, Julien; Tualle-Brouri, Rosa; Grangier, Philippe

    2009-01-01

    Entangled coherent states can be prepared remotely by subtracting non-locally a single photon from two quantum superpositions of coherent states, the so-called "Schroedinger's cat" state. Such entanglement can further be distributed over longer distances by successive entanglement swapping operations using linear optics and photon-number resolving detectors. The aim of this paper is to evaluate the performance of this approach to quantum repeaters for long distance quantum communications. Despite many attractive features at first sight, we show that, when using state-of-the-art photon counters and quantum memories, they do not achieve higher entanglement generation rates than repeaters based on single-photon entanglement. We discuss potential developments which may take better advantage of the richness of entanglement based on continuous variables, including in particular efficient parity measurements.

  11. Anodal Transcranial Direct Current Stimulation Shows Minimal, Measure-Specific Effects on Dynamic Postural Control in Young and Older Adults: A Double Blind, Sham-Controlled Study.

    Science.gov (United States)

    Craig, Chesney E; Doumas, Michail

    2017-01-01

    We investigated whether stimulating the cerebellum and primary motor cortex (M1) using transcranial direct current stimulation (tDCS) could affect postural control in young and older adults. tDCS was employed using a double-blind, sham-controlled design, in which young (aged 18-35) and older adults (aged 65+) were assessed over three sessions, one for each stimulatory condition-M1, cerebellar and sham. The effect of tDCS on postural control was assessed using a sway-referencing paradigm, which induced platform rotations in proportion to the participant's body sway, thus assessing sensory reweighting processes. Task difficulty was manipulated so that young adults experienced a support surface that was twice as compliant as that of older adults, in order to minimise baseline age differences in postural sway. Effects of tDCS on postural control were assessed during, immediately after and 30 minutes after tDCS. Additionally, the effect of tDCS on corticospinal excitability was measured by evaluating motor evoked potentials using transcranial magnetic stimulation immediately after and 30 minutes after tDCS. Minimal effects of tDCS on postural control were found in the eyes open condition only, and this was dependent on the measure assessed and age group. For young adults, stimulation had only offline effects, as cerebellar stimulation showed higher mean power frequency (MPF) of sway 30 minutes after stimulation. For older adults, both stimulation conditions delayed the increase in sway amplitude witnessed between blocks one and two until stimulation was no longer active. In conclusion, despite tDCS' growing popularity, we would caution researchers to consider carefully the type of measures assessed and the groups targeted in tDCS studies of postural control.

  12. Analysis of conservative tracer measurement results using the Frechet distribution at planted horizontal subsurface flow constructed wetlands filled with coarse gravel and showing the effect of clogging processes.

    Science.gov (United States)

    Dittrich, Ernő; Klincsik, Mihály

    2015-11-01

    A mathematical process, developed in Maple environment, has been successful in decreasing the error of measurement results and in the precise calculation of the moments of corrected tracer functions. It was proved that with this process, the measured tracer results of horizontal subsurface flow constructed wetlands filled with coarse gravel (HSFCW-C) can be fitted more accurately than with the conventionally used distribution functions (Gaussian, Lognormal, Fick (Inverse Gaussian) and Gamma). This statement is true only for the planted HSFCW-Cs. The analysis of unplanted HSFCW-Cs needs more research. The result of the analysis shows that the conventional solutions (completely stirred series tank reactor (CSTR) model and convection-dispersion transport (CDT) model) cannot describe these types of transport processes with sufficient accuracy. These outcomes can help in developing better process descriptions of very difficult transport processes in HSFCW-Cs. Furthermore, a new mathematical process can be developed for the calculation of real hydraulic residence time (HRT) and dispersion coefficient values. The presented method can be generalized to other kinds of hydraulic environments.

  13. A COMPARISON OF PAIRS FIGURE SKATERS IN REPEATED JUMPS

    Directory of Open Access Journals (Sweden)

    William A. Sands

    2012-03-01

    Full Text Available Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare

  14. Quantum key distribution with two-segment quantum repeaters

    Energy Technology Data Exchange (ETDEWEB)

    Kampermann, Hermann; Abruzzo, Silvestre; Bruss, Dagmar [Theoretische Physik III, Heinrich-Heine-Universitaet Duesseldorf (Germany)

    2014-07-01

    Quantum repeaters represent one possible way to achieve long-distance quantum key distribution. One way of improving the repeater rate and decreasing the memory coherence time is the usage of multiplexing. Motivated by the experimental fact that long-range connections are practically demanding, we extend the analysis of the quantum repeater multiplexing protocol to the case of short-range connections. We derive formulas for the repeater rate and we show that short-range connections lead to most of the benefits of a full-range multiplexing protocol. A less demanding QKD-protocol without quantum memories was recently introduced by Lo et al. We generalize this measurement-device-independent quantum key Distribution protocol to the scenario where the repeater Station contains also heralded quantum memories. We assume either single-photon sources or weak coherent pulse sources plus decay states. We show that it is possible to significantly outperform the original proposal, even in presence of decoherence of the quantum memory. We give formulas in terms of device imperfections i.e., the quantum bit error rate and the repeater rate.

  15. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  16. Mining of simple sequence repeats in the Genome of Gentianaceae

    Directory of Open Access Journals (Sweden)

    R Sathishkumar

    2011-01-01

    Full Text Available Simple sequence repeats (SSRs or short tandem repeats are short repeat motifs that show high level of length polymorphism due to insertion or deletion mutations of one or more repeat types. Here, we present the detection and abundance of microsatellites or SSRs in nucleotide sequences of Gentianaceae family. A total of 545 SSRs were mined in 4698 nucleotide sequences downloaded from the National Center for Biotechnology Information (NCBI. Among the SSR sequences, the frequency of repeat type was about 429 -mono repeats, 99 -di repeats, 15 -tri repeats, and 2 --hexa repeats. Mononucleotide repeats were found to be abundant repeat types, about 78%, followed by dinucleotide repeats (18.16% among the SSR sequences. An attempt was made to design primer pairs for 545 identified SSRs but these were found only for 169 sequences.

  17. 重复测试和不同性别对小鼠旷场行为的影响%Repeated Measurement and Sex for the Behavior in Open Field in Mice

    Institute of Scientific and Technical Information of China (English)

    陈超杰; 钟志凤; 俞昌喜

    2014-01-01

    OBJECTIVE To study the effect on the locomotory activity and anxiety-like behavior of laboratory mice by both factors of repeated measurement and sex.METHODS The total distance traveled ,total mean velocity , total parallel index,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone en-tries,the percentage of time spent in center zone and the parallel index in center zone of the female and male mice for 5 minutes were recorded and analyzed in open field test by animal video tracking analysis system ,once a day for 3 days.RESULTS In the open field test ,the indexes of the total distance traveled ,total mean velocity ,total parallel index ,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone entries ,the percent-age of time spent in center zone and the parallel index in center zone in mice showed the downtrend as the measure -ment numbers were increasing ( P0.05 ).However ,as repeating the tests ,the downtrend of these in male mice were seemly more significant than female mice ,especially in the third time measurement ,in which the mean velocity ( P<0.05 ) and parallel index ( P<0.01 ) in center zone were lower than the ones in female mice ,respectively.CONCLUSION The repeated measurement inferences the locomotory activity and interrupted the anxiety state of mice.Sex of mice does not make the behavior in open field different at the first time ,but the repeated measurement seemly more signifi-cantly affect the locomotory activity of the male mice than the female.%目的:研究重复测试和不同性别两个因素对小鼠在旷场试验中自主行为活动和焦虑行为的影响。方法通过动物视频行为分析系统,分别记录和分析雌雄小鼠5 min内在旷场中的总路程、总体平均速度、总体平行指数、中央区的路程占总路程的比例、中央区的平均速度、中央区进入次数、中央区停留时间占整体测试时间的比例和中

  18. Violence and TV Shows

    OpenAIRE

    ÖZTÜRK, Yrd. Doç. Dr. Şinasi

    2008-01-01

    This study aims to discuss theories on theviolent effects of TV shows on viewers, especiallyon children. Therefore, this study includes a briefdiscussion of definitions of violence, discussionof violence theories, main results of researcheson televised violence, measuring TV violence,perception of televised violence, individualdifferences and reactions to TV violence,aggressiveness and preferences for TV violence.

  19. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  20. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  1. Repeatability and consistency of individual behaviour in juvenile and adult Eurasian harvest mice

    Science.gov (United States)

    Schuster, Andrea C.; Carl, Teresa; Foerster, Katharina

    2017-04-01

    Knowledge on animal personality has provided new insights into evolutionary biology and animal ecology, as behavioural types have been shown to affect fitness. Animal personality is characterized by repeatable and consistent between-individual behavioural differences throughout time and across different situations. Behavioural repeatability within life history stages and consistency between life history stages should be checked for the independence of sex and age, as recent data have shown that males and females in some species may differ in the repeatability of behavioural traits, as well as in their consistency. We measured the repeatability and consistency of three behavioural and one cognitive traits in juvenile and adult Eurasian harvest mice ( Micromys minutus). We found that exploration, activity and boldness were repeatable in juveniles and adults. Spatial recognition measured in a Y Maze was only repeatable in adult mice. Exploration, activity and boldness were consistent before and after maturation, as well as before and after first sexual contact. Data on spatial recognition provided little evidence for consistency. Further, we found some evidence for a litter effect on behaviours by comparing different linear mixed models. We concluded that harvest mice express animal personality traits as behaviours were repeatable across sexes and consistent across life history stages. The tested cognitive trait showed low repeatability and was less consistent across life history stages. Given the rising interest in individual variation in cognitive performance, and in its relationship to animal personality, we suggest that it is important to gather more data on the repeatability and consistency of cognitive traits.

  2. Recursive quantum repeater networks

    CERN Document Server

    Van Meter, Rodney; Horsman, Clare

    2011-01-01

    Internet-scale quantum repeater networks will be heterogeneous in physical technology, repeater functionality, and management. The classical control necessary to use the network will therefore face similar issues as Internet data transmission. Many scalability and management problems that arose during the development of the Internet might have been solved in a more uniform fashion, improving flexibility and reducing redundant engineering effort. Quantum repeater network development is currently at the stage where we risk similar duplication when separate systems are combined. We propose a unifying framework that can be used with all existing repeater designs. We introduce the notion of a Quantum Recursive Network Architecture, developed from the emerging classical concept of 'recursive networks', extending recursive mechanisms from a focus on data forwarding to a more general distributed computing request framework. Recursion abstracts independent transit networks as single relay nodes, unifies software layer...

  3. Relationships between anthropometric measures and athletic performance, with special reference to repeated-sprint ability, in the Qatar national soccer team.

    Science.gov (United States)

    Brocherie, Franck; Girard, Olivier; Forchino, Fabricio; Al Haddad, Hani; Dos Santos, Gilvan A; Millet, Grégoire P

    2014-01-01

    The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.

  4. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  5. Dissolved Fe(II) in the Pacific Ocean: Measurements from the P16N CLIVAR/CO2 Repeat Hydrography Cruise

    Science.gov (United States)

    Hansard, S. P.; Landing, W. M.; Measures, C. I.

    2006-12-01

    Vertical profiles of seawater Fe(II) concentration were obtained for 37 stations sampled in early 2006, in conjunction with the CLIVAR Repeat Hydrography P16N transect (152° W, Tahiti to Alaska). At each station, seawater samples were collected from 12 target depths (0-1000 m) using trace-metal clean Go-Flo bottles. Upon recovery, Go-Flo bottles were immediately transferred to a Class 100 clean van and sub-sampled for Fe(II) by passing sample water through a 0.2 μm Supor (polyethersulfone) cartridge filter into 125 mL containers, pre-loaded with 25 μL of 6M quartz-distilled HCl (final pH ~~ 6) to slow oxidation. Samples were immediately analyzed for Fe(II) using a luminol-based chemiluminescence method. Total dissolved iron was also determined shipboard by spectrophotometric flow injection analysis. The data collected from this cruise will be presented, along with corroborating data from another North Pacific cruise (PO2). Concentrations of Fe(II) ranged from below detection (meters. Photoreduction of Fe(III) has been cited as a source of Fe(II) in surface waters, and the pattern of attenuation with depth is consistent with this mechanism. Many samples collected at or near the bottom of the profile (500-1000 m) exhibited elevated Fe(II) relative to the mid-depths of the profile. Due to the higher total dissolved iron at depth, the percentage of Fe(II) was low in these samples. Recent studies support the presence of Fe(II) at depth, in association with low or suboxic conditions. In situ processes such as the remineralization of sinking biogenic particles may provide a source for this Fe(II).

  6. Regional differences of repeatability on visual analogue scale with experimental mechanical pain stimuli.

    Science.gov (United States)

    Hayashi, Kazuhiro; Ikemoto, Tatsunori; Ueno, Takefumi; Arai, Young-Chang P; Shimo, Kazuhiro; Nishihara, Makoto; Suzuki, Shigeyuki; Ushida, Takahiro

    2015-01-12

    Pain-VAS is quite subjective as a scale, but has a tendency to assume differences in repeatability in accordance with perceived pain intensity. The aim of the present study was to investigate the repeatability of regional differences with ratings of pain-VAS. Three experimental mechanical stimuli were applied to twenty seven healthy volunteers across four sessions over four weeks within individuals. The same stimuli were also simultaneously measured in the same manner with an electric balance. The magnitude of mechanical stimuli was determined by 100 g, 300 g, and 600 g monofilaments. Standard deviations (SDs) across measurements with an electric balance showed a regular increase with stimulus magnitude, while coefficient variations (CVs) were constant in each stimulus. On the other hand, although SDs across pain-VAS measurements were significantly greater with the 300 g filament than with the 100 g and 600 g filaments, CVs showed a regular decrease in magnitude of stimulus. These results showed that the CVs of repeated measurement with electric balance were consistent regardless of stimulus intensity, in contrast, CVs of pain-VAS decreased with greater pain rating averaged by repeated measurement. These results suggest that a low rating in pain-VAS is inherently less objective, indicating poor repeatability. In contrast, a high rating in pain-VAS is more objective with better repeatability for experimental pain perception.

  7. Childhood experiences and repeated suicidal behavior

    DEFF Research Database (Denmark)

    Krarup, Gertrud; Nielsen, Bent; Rask, P

    1991-01-01

    The aim of this study was to elucidate the influence of various events in childhood on suicidal behavior in adult age. For this purpose, 99 patients admitted to the Department of Psychiatry of Odense University Hospital after making a suicide attempt were followed for 5 years, to register repeated...... suicidal behavior. The results showed that three fourths of the patients attempted suicide more than once (62% nonfatal and 14% fatal outcome). The sex distribution was about the same among the first-evers as among the repeaters. Most repeaters were younger people in their twenties and thirties......, and the first-evers on average were past the age of 40. Somewhat unexpectedly, significantly more repeaters than first-evers had grown up with both their parents. However, the results also showed that significantly more repeaters than first-evers had had an unhappy childhood. This indicates...

  8. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    OpenAIRE

    Smedslund Geir; Zangi Heidi Andersen; Mowinckel Petter; Hagen Kåre Birger

    2013-01-01

    Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71)...

  9. The Pentapeptide Repeat Proteins

    Energy Technology Data Exchange (ETDEWEB)

    Vetting,M.; Hegde, S.; Fajardo, J.; Fiser, A.; Roderick, S.; Takiff, H.; Blanchard, J.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S, T,A, V][D, N][L, F]-[S, T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Mycobacterium tuberculosis. The structure revealed that the pentapeptide repeats encode the folding of a novel right-handed quadrilateral {beta}-helix. MfpA binds to DNA gyrase and inhibits its activity. The rod-shaped, dimeric protein exhibits remarkable size, shape and electrostatic similarity to DNA.

  10. Oxygen uptake during repeated-sprint exercise.

    Science.gov (United States)

    McGawley, Kerry; Bishop, David J

    2015-03-01

    Repeated-sprint ability appears to be influenced by oxidative metabolism, with reductions in fatigue and improved sprint times related to markers of aerobic fitness. The aim of the current study was to measure the oxygen uptake (VO₂) during the first and last sprints during two, 5 × 6-s repeated-sprint bouts. Cross-sectional study. Eight female soccer players performed two, consecutive, 5 × 6-s maximal sprint bouts (B1 and B2) on five separate occasions, in order to identify the minimum time (trec) required to recover total work done (Wtot) in B1. On a sixth occasion, expired air was collected during the first and last sprint of B1 and B2, which were separated by trec. The trec was 10.9 ± 1.1 min. The VO₂ during the first sprint was significantly less than the last sprint in each bout (psprint (measured in kJ) was significantly related to VO₂max in both B1 (r=0.81, p=0.015) and B2 (r=0.93, p=0.001). In addition, the VO₂ attained in the final sprint was not significantly different from VO₂max in B1 (p=0.284) or B2 (p=0.448). The current study shows that the VO₂ increases from the first to the last of 5 × 6-s sprints and that VO₂max may be a limiting factor to performance in latter sprints. Increasing V˙O₂max in team-sport athletes may enable increased aerobic energy delivery, and consequently work done, during a bout of repeated sprints. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. Repeating the Past

    Science.gov (United States)

    Moore, John W.

    1998-05-01

    As part of the celebration of the Journal 's 75th year, we are scanning each Journal issue from 25, 50, and 74 years ago. Many of the ideas and practices described are so similar to present-day "innovations" that George Santayana's adage (1) "Those who cannot remember the past are condemned to repeat it" comes to mind. But perhaps "condemned" is too strong - sometimes it may be valuable to repeat something that was done long ago. One example comes from the earliest days of the Division of Chemical Education and of the Journal.

  12. Repeatability and Minimal Detectable Change in Longitudinal Median Nerve Excursion Measures During Upper Limb Neurodynamic Techniques in a Mixed Population: A Pilot Study Using Musculoskeletal Ultrasound Imaging.

    Science.gov (United States)

    Paquette, Philippe; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2015-07-01

    This study determined test-retest reliability and minimum detectable change in longitudinal median nerve excursion during upper limb neurodynamic tests (ULNTs). Seven participants with unilateral or bilateral carpal tunnel syndrome and 11 healthy participants were randomly tested with two ULNTs (i.e., tensioner and slider). Each ULNT was performed three times each at 45° and 90° of shoulder abduction on two separate visits. Video sequences of median nerve excursion, recorded by a physical therapist using ultrasound imaging, were quantified using computer software. The generalizability theory, encompassing a G-Study and a D-study, measured the dependability coefficient (Φ) along with standard error of measurement (SEM) accuracy and allowed various testing protocols to be proposed. The highest reliability (Φ = 0.84) and lowest minimal measurement error (SEM = 0.58 mm) of the longitudinal median nerve excursion were reached during the ULNT-slider performed with 45° of shoulder abduction and when measures obtained from three different image sequences recorded during a single visit were averaged. It is recommended that longitudinal median nerve excursion measures computed from three separate image sequences recorded during a single visit be averaged in clinical practice. Ideally, adding a second visit (six image sequences) is also suggested in research protocols.

  13. Impact of volunteer-related and methodology-related factors on the reproducibility of brachial artery flow-mediated vasodilation: analysis of 672 individual repeated measurements.

    NARCIS (Netherlands)

    Mil, A.C.C.M. van; Greyling, A.; Zock, P.L.; Geleijnse, J.M.; Hopman, M.T.E.; Mensink, R.P.; Reesink, K.D.; Green, D.J.; Ghiadoni, L.; Thijssen, D.H.J.

    2016-01-01

    OBJECTIVES: Brachial artery flow-mediated dilation (FMD) is a popular technique to examine endothelial function in humans. Identifying volunteer and methodological factors related to variation in FMD is important to improve measurement accuracy and applicability. METHODS: Volunteer-related and

  14. 数字光纤直放站中的时延测量与校正%The Measurement and Adjustment of Time Delay in Digital Optical Fiber Repeater

    Institute of Scientific and Technical Information of China (English)

    金绍春

    2011-01-01

    提出了应用于数字光纤直放站的时延测量与校正方法。阐述了数字光纤直放站的结构、时延测量的目的与原理、时延校正的计算。时延测量以CPRI协议为基础,包括光纤时延测量、转发时延测量。时延校正分下行时延校正和上行时延校正。下行时延校正是使同一台REC送出的IQ信号在不同的RE中能够同时射频发送出去。上行时延校正是使不同的RE接收到的IQ信号能够正确进行功率合成。%The Method of measurement and adjustment of time delay which applies to digital optical fiber repeater has been presented. The structure of digital optical fiber repeater, the purpose and principle of time delay measurement, the calculation of time delay adjustment, has been represented. The measurement of time delay that based on CPRI protocol includes the measurement of optical fiber time delay and the measurement of forward time delay. The time delay adjustment includes uplink time delay adjustment and downlink time delay adjustment. The purpose of downlink time delay adjustment is to ensure IQ signals in different REs which comes from the same REC transmit synchronously by radio frequency signals. The purpose of uplink time delay adjustment is to ensure received IQ signals by different REs synthesize correctly by power.

  15. Flight and wind-tunnel measurements showing base drag reduction provided by a trailing disk for high Reynolds number turbulent flow for subsonic and transonic Mach numbers

    Science.gov (United States)

    Powers, Sheryll Goecke; Huffman, Jarrett K.; Fox, Charles H., Jr.

    1986-01-01

    The effectiveness of a trailing disk, or trapped vortex concept, in reducing the base drag of a large body of revolution was studied from measurements made both in flight and in a wind tunnel. Pressure data obtained for the flight experiment, and both pressure and force balance data were obtained for the wind tunnel experiment. The flight test also included data obtained from a hemispherical base. The experiment demonstrated the significant base drag reduction capability of the trailing disk to Mach 0.93 and to Reynolds numbers up to 80 times greater than for earlier studies. For the trailing disk data from the flight experiment, the maximum decrease in base drag ranged form 0.08 to 0.07 as Mach number increased from 0.70 to 0.93. Aircraft angles of attack ranged from 3.9 to 6.6 deg for the flight data. For the trailing disk data from the wind tunnel experiment, the maximum decrease in base and total drag ranged from 0.08 to 0.05 for the approximately 0 deg angle of attack data as Mach number increased from 0.30 to 0.82.

  16. Age, CAG repeat length, and clinical progression in Huntington's disease.

    Science.gov (United States)

    Rosenblatt, Adam; Kumar, Brahma V; Mo, Alisa; Welsh, Claire S; Margolis, Russell L; Ross, Christopher A

    2012-02-01

    The objective of this study was to further explore the effect of CAG repeat length on the rate of clinical progression in patients with Huntington's disease. The dataset included records for 569 subjects followed prospectively at the Baltimore Huntington's Disease Center. Participants were seen for a mean of 7.1 visits, with a mean follow-up of 8.2 years. Subjects were evaluated using the Quantified Neurologic Examination and its Motor Impairment subscale, the Mini-Mental State Examination, and the Huntington's disease Activities of Daily Living Scale. By itself, CAG repeat length showed a statistically significant but small effect on the progression of all clinical measures. Contrary to our previous expectations, controlling for age of onset increased the correlation between CAG repeat length and progression of all variables by 69% to 159%. Graphical models further supported the idea that individuals with smaller triplet expansions experience a more gradual decline. CAG repeat length becomes an important determinant of clinical prognosis when accounting for age of onset. This suggests that the aging process itself influences clinical outcomes in Huntington's disease. Inconsistent results in prior studies examining CAG repeat length and progression may indeed reflect a lack of age adjustment.

  17. All-optical repeater.

    Science.gov (United States)

    Silberberg, Y

    1986-06-01

    An all-optical device containing saturable gain, saturable loss, and unsaturable loss is shown to transform weak, distorted optical pulses into uniform standard-shape pulses. The proposed device performs thresholding, amplification, and pulse shaping as required from an optical repeater. It is shown that such a device could be realized by existing semiconductor technology.

  18. Bidirectional Manchester repeater

    Science.gov (United States)

    Ferguson, J.

    1980-01-01

    Bidirectional Manchester repeater is inserted at periodic intervals along single bidirectional twisted pair transmission line to detect, amplify, and transmit bidirectional Manchester 11 code signals. Requiring only 18 TTL 7400 series IC's, some line receivers and drivers, and handful of passive components, circuit is simple and relatively inexpensive to build.

  19. A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese

    Energy Technology Data Exchange (ETDEWEB)

    Bing-wen Soong; Jih-tsuu Wang [Neurological Institute, Taipei (Taiwan, Province of China)

    1994-09-01

    Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in the major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.

  20. Long-term elastic durability of polymer matrix composite materials after repeated steam sterilization.

    Science.gov (United States)

    Chong, Alexander C M; Fischer, Gustav; Dart, Bradley R; Wooley, Paul H

    2015-11-01

    We compared the durability of 3 different selected composite materials that underwent repeated steam sterilization with the durability of traditional metal materials. Composite materials Tepex, CFR-PPS (carbon-fiber-reinforced polyphenylene sulfide), and HTN-53 (Zytel HTN53G50HSLR NC010) were evaluated for durability and water retention after repeated steam sterilization. These composites were compared with stainless steel and aluminum. The structural properties of these materials were measured (short-beam load-to-failure and cyclic compression loading tests) before, during, and after repeated steam sterilization. The relative radiographic density of these materials was also compared. There was no significant difference in the moisture retention of these composite materials before and after repeated sterilization. The composite materials were significantly more radiolucent than the metals. For all the composite materials, load to failure deteriorated after repeated sterilization. The cyclic compression loading tests showed HTN-53 had the poorest performance, with complete failure after 400 cycles of repeated sterilization. CFR-PPS performed slightly better, with 33% failure at final testing. Tepex had no failures at final testing. Although HTN-53 has shown promise in other orthopedic applications, its performance after repeated sterilization was relatively poor. Tepex showed the most potential for durability after repeated sterilization. Further study is needed to identify specific applications for these materials in the orthopedic industry.

  1. Hypothyroid patients showing shortened responsiveness to oral iodized oil have paradoxically low serum thyroglobulin and low thyroid reserve. Thyroglobulin/thyrotropin ratio as a measure of thyroid damage.

    Science.gov (United States)

    Contempre, B; Duale, G L; Gervy, C; Alexandre, J; Vanovervelt, N; Dumont, J E

    1996-03-01

    In Central Africa, all of northern Zaire is very severely deficient in iodine. A peculiar feature of this endemia is that iodine deficiency and the ensuing thyroid gland stimulation not only leads to goitre formation but also to progressive thyroid involution and to myxoedematous cretinism. An iodine supplementation trial based on oral administration of small doses of iodine was made in 81 schoolchildren. All of them received a small dose of iodine (0.1 ml containing 48 mg) per os and the thyroid status was followed during 4 months. Blood and urine samples were collected at the start of the study, then 2 weeks, 2 months and 4 months after iodine administration. Before iodine supplementation the mean urinary iodine level was 0.18 +/- 0.02 micromol/l, and 10% of the subjects had a urinary iodine level below 0.08 micromol/l. Fifty-two percent of the subjects had a serum thyrotropin (TSH) level above 10 mU/l. All the subjects responded to the administration of iodine. and all of them recovered a euthyroid status. Most of them were still euthyroid at the end of the study. However. within 4 or even 2 months, some subjects (15 % of the total) reverted to hypothyroidism. At the entry of the study these subjects were all hypothyroid and had elevated TSH and paradoxically low serum thyroglobulin (TG) values. In myxoedematous cretins living in the same area, even lower serum TG levels were found. Together with the absence of goitre, a paradoxically low serum TG Suggests a low thyroid reserve, and in the present case a reduced amount of functional thyroid tissue. We show that the serum TG/TSH ratio may be used as a predictive index of thyroid reserve and of positive response to iodine administration. These data further suggest that thyroid damage is not confined to myxoedematous cretins. but is widely distributed in the phenotypically normal population. Widely distributed thyroid damage may render iodine prophylaxis based on oral administration unpredictable.

  2. The child accident repeater: a review.

    Science.gov (United States)

    Jones, J G

    1980-04-01

    The child accident repeater is defined as one who has at least three accidents that come to medical attention within a year. The accident situation has features in common with those of the child who has a single accident through simple "bad luck", but other factors predispose him to repeated injury. In the child who has a susceptible personality, a tendency for accident repetition may be due to a breakdown in adjustment to a stressful environment. Prevention of repeat accidents should involve the usual measures considered appropriate for all children as well as an attempt to provide treatment of significant maladjustment and modification of a stressful environment.

  3. Burnout as a risk factor for antidepressant treatment - a repeated measures time-to-event analysis of 2936 Danish human service workers

    DEFF Research Database (Denmark)

    Madsen, Ida E H; Lange, Theis; Borritz, Marianne

    2015-01-01

    Burnout is a state of emotional exhaustion, feelings of reduced personal accomplishment, and withdrawal from work thought to occur as a consequence of prolonged occupational stress. The condition is not included in the diagnostic classifications, but is considered likely to develop into depressive...... disorder in some cases. We examined the prospective association between burnout and antidepressant treatment, as an indicator of clinically significant mental disorder. We further investigated potential effect-modifiers of the association, to identify factors that may prevent this progression of burnout...... modeling, examining the risk of entering antidepressant treatment in relation to the level of work-related burnout measured by the Copenhagen Burnout inventory. As effect-modifiers we examined both sociodemographic factors and a range of psychosocial work environment factors. The level of burnout predicted...

  4. County level socioeconomic position, work organization and depression disorder: a repeated measures cross-classified multilevel analysis of low-income nursing home workers.

    Science.gov (United States)

    Muntaner, Carles; Li, Yong; Xue, Xiaonan; Thompson, Theresa; O'Campo, Patricia; Chung, Haejoo; Eaton, William W

    2006-12-01

    This study simultaneously tests the effect of county, organizational, workplace, and individual level variables on depressive disorders among low-income nursing assistants employed in US nursing homes. A total of 482 observations are used from two waves of survey data collection, with an average two-year interval between initial and follow-up surveys. The overall response rate was 62 percent. The hierarchically structured data was analyzed using multilevel modeling to account for cross-classifications across levels of data. Nursing assistants working in nursing homes covered by a single union in three states were asked about aspects of their working conditions, job stress, physical and mental health status, individual and family health-care needs, household economics and household strain. The 241 nursing assistants who participated in this study were employed in 34 nursing homes and lived in 49 counties of West Virginia, Ohio and Kentucky. The study finds that emotional strain, related to providing direct care to elderly and disabled clients, is associated with depressive disorder, as is nursing home ownership type (for-profit versus not-for-profit). However, when controlling for county level socioeconomic variables (Gini index and proportion of African Americans living in the county), neither workplace nor organizational level variables were found to be statistically significant associated with depressive disorder. This study supports previous findings that emotional demand in health-care environments is an important correlate of mental health. It also adds empirical evidence to support a link between financial strain and depression in US women. While this study does not find that lack of a seniority wage benefits--a factor that can conceivably exacerbate financial strain over time--is associated with depressive disorder among low-income health-care workers, it does find county level measures of poverty to be statistically significant predictors of depressive

  5. Dynamics of Graft Function Measured by DNA-Technology in a Patient with Severe Aplastic Anemia and Repeated Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Anna Karastaneva

    2014-01-01

    Full Text Available Although bone marrow transplantation (BMT from an HLA identical sibling is considered as treatment of choice in pediatric patients with severe aplastic anemia (SAA, a significant number of them experience graft failure (GF after BMT. We report a case of an 8-year-old male patient with SAA who presented with a complicated posttransplant course due to parvovirus B19 infection and GF. A subsequent attempt to support the graft by antithymocyte globulin (ATG and a peripheral stem cell boost resulted in transitory autologous recovery of hematopoiesis followed by mixed chimerism, supported by donor lymphocyte infusions (DLIs and finally graft rejection with relapse of SAA. Permanent complete chimerism was achieved by a second BMT. Dynamics of graft function, measured by a single nucleotide polymorphism (SNPs analysis, are discussed.

  6. Long-term aerobic exercise and omega-3 supplementation modulate osteoporosis through inflammatory mechanisms in post-menopausal women: a randomized, repeated measures study

    Directory of Open Access Journals (Sweden)

    Kanaley Jill

    2011-10-01

    Full Text Available Abstract Background Evidence indicates that dietary fats and physical activity influence bone health. The purpose of this study was to examine the effects of long-term aerobic exercise and omega-3 (N-3 supplementation on serum inflammatory markers, bone mineral density (BMD, and bone biomarkers in post-menopausal women. Methods Seventy-nine healthy sedentary post-menopausal women aged 58-78 years participated in this study. Subjects were randomized to one of 4 groups: exercise + supplement (E+S, n = 21, exercise (E, n = 20, supplement (S, n = 20, and control (Con, n = 18 groups. The subjects in the E+S and E groups performed aerobic exercise training (walking and jogging up to 65% of HRmax, three times a week for 24 weeks. Subjects in the E+S and S groups consumed 1000 mg/d N-3 for 24 weeks. The lumbar spine (L2-L4 and femoral neck BMD, serum tumor necrosis factor (TNF α, interleukin (IL 6, prostaglandin (PG E2, estrogen, osteocalcin, 1, 25-dihydroxyvitamin D3 (1, 25 Vit D, C-telopeptide (CTX, parathyroid hormone (PTH and calcitonin (CT were measured at baseline, the end of week 12 and 24. Results Serum estrogen, osteocalcin, 1, 25 Vit D, CT, L2-L4 and femoral neck BMD measures increased (P 2 decreased (P 2-L4 and femoral neck BMD, estrogen, osteocalcin, and CT were negatively (P 2. PTH and CT were correlated positively and negatively with IL-6, respectively (P Conclusions The present study demonstrates that long-term aerobic exercise training plus N-3 supplementation have a synergistic effect in attenuating inflammation and augmenting BMD in post-menopausal osteoporosis.

  7. The use of linear mixed models for analysis of repeated measurements applied to water-soluble carbohydrates in perennial ryegrass for seed production

    DEFF Research Database (Denmark)

    Gislum, René; Boelt, Birte; Zhang, Xia

    2009-01-01

    symmetry, and first-order antedependence. The Akaike Information Criterion and the Bayesian Information Criterion were used to find the best covariance structure. The choice of covariance structure had an effect on the significance levels for the stem data, whereas no effect was observed for the ear data...... was given to the Bayesian information criteria than to the Akaike information criteria. Accordingly, the compound symmetry structure was chosen for the stem data and the unstructured structure was found to be the best structure for the ear data. A model check of the residuals showed...

  8. Perfusion CT measurements in healthy cervical spinal cord: feasibility and repeatability of the study as well as interchangeability of the perfusion estimates using two commercially available software packages

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [Johann Wolfgang University Hospital, Department of Radiology, Frankfurt (Germany); Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Johann Wolfgang Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Rumboldt, Zoran; Deveikis, John; Spampinato, Maria Vittoria [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Surlan, Katarina [Clinical Centre Ljubljana, Department of Clinical Radiology, Ljubljana (Slovenia); Koh, Tong San [Nanyang Technological University, School of Electrical and Electronic Engineering, Singapore (Singapore)

    2008-10-15

    Our purpose was to examine the feasibility and reproducibility of perfusion CT studies in the cervical spinal cord and the interchangeability of the values obtained by two post-processing methods. The perfusion CT studies of 40 patients with neck tumours were post-processed using two software packages (Software-1: deconvolution-based analysis with adiabatic tissue homogeneity approach and Software-2: maximum-slope-model with Patlak analysis). Eight patients were examined twice for assessing the reproducibility of the technique. Two neuroradiologists separately post-processed the images with two arterial input functions (AIFs): (1) the internal carotid artery (ICA) and (2) the vertebral artery (VA). Maps of blood flow (F) in ml/min/100 g, blood volume (V) in ml/100 g, mean transit time (MTT) in seconds (s) and permeability (PS) in ml/min/100 g were generated. The mean F, V, MTT and PS (Software-1) with VA-AIF and ICA-AIF were 8.93, 1.12, 16.3, 1.88 and 8.57, 1.19, 16.85 and 1.94, respectively. The reproducibility of the techniques was satisfactory, while the V and MTT values (in Software-1) and the F and V values (in Software-2) were dependent on the site of the AIF (p{>=}0.03 and p=0.02, respectively). The interobserver agreement was very good. The significant differences in measurements for a single patient (%) using Software-1/Software-2 were {+-}120%/110%, 90%/80%, 180% and 250%/130% for F, V, MTT and PS, respectively. Only F and PS values in the healthy tissue seemed to be interchangeable. Our results were in essential agreement with those derived by invasive measurements in animals. The cervical spine perfusion CT studies are feasible and reproducible. The present knowledge has to be validated with studies in spinal cord tumours in order to decide the usefulness of the perfusion CT in this field. (orig.)

  9. Evaluation of repeated measurements of radon-222 concentrations in well water sampled from bedrock aquifers of the Piedmont near Richmond, Virginia, USA: effects of lithology and well characteristics.

    Science.gov (United States)

    Harris, Shelley A; Billmeyer, Ernest R; Robinson, Michael A

    2006-07-01

    Radon (222Rn) concentrations in 26 ground water wells of two distinct lithologies in the Piedmont of Virginia were measured to assess variation in ground water radon concentrations (GWRC), to evaluate differences in concentrations related to well characteristics, lithology, and spatial distributions, and to assess the feasibility of predicting GWRC. Wells were sampled in accordance with American Public Health Association Method 7500 Rn-B, with modifications to include a well shaft profile analysis that determined the minimum purge time sufficient to remove the equivalent of one column of water from each well. Statistically significant differences in GWRC were found in the Trssu (1482 +/- 1711 pCi/L) and Mpg (7750 +/- 5188 pCi/L) lithologies, however, no significant differences were found among GWRC at each well over time. Using multiple regression, 86% of the variability (R2) in the GWRC was explained by the lithology, latitudinal class, and water table elevation of the wells. The GWRC in a majority of the wells studied exceed US Environmental Protection Agency designated maximum contaminant level and AMCL. Results support modifications to sampling procedures and indicate that, in previous studies, variations in GWRC concentrations over time may have been due in part to differences in sampling procedures and not in source water.

  10. Relative contributions of interface pressure, shear stress, and temperature on ischemic-induced, skin-reactive hyperemia in healthy volunteers: a repeated measures laboratory study.

    Science.gov (United States)

    Lachenbruch, Charlie; Tzen, Yi-Ting; Brienza, David; Karg, Patricia E; Lachenbruch, Peter A

    2015-02-01

    Although the primary risk factors for pressure ulcer development - pressure, shear, skin temperature, moisture, and friction - have been identified for decades, the relative contribution of each to this risk remains unclear. To confirm the results of and expand upon earlier research into the relative contributions of interface pressures, shear stress, and skin temperature among 4 healthy volunteers, a study involving 6 additional healthy 40- to 75-year-old volunteers was conducted and results of the 2 studies were pooled. All 3 variables (interface pressures, shear stress, and skin temperature) were systematically and randomly varied. In the prone position, volunteers each underwent 18 test conditions representing different combinations of temperature (28˚ C, 32˚ C, 36˚ C), pressure (8.0 and 13.3 kPa), and shear (0, 6.7, and 14.0 kPa) using a computer-controlled indenter applied to the sacrum for 20 minutes exerting weights of 100 g and 200 g to induce 0.98 N and 1.96 N of shear force, respectively. Each condition was tested twice, resulting in a total of 360 trials. Magnitude of postload reactive hyperemia as an index of ischemia was measured by laser Doppler flowmetry. Fixed effects regression models were used to predict 3 different indices of reactive hyperemic magnitude. Friedman tests were performed to compare the reactive hyperemia among 3 different skin temperatures or shear stresses under the same amount of localized pressure. In all regression models, pressure and temperature were highly significant predictors of the extent of reactive hyperemia (P pressure and shear stress, and the difference was more profound between 32˚ C and 36˚ C than between 28˚ C and 32˚ C. These results confirm that, in laboratory settings, temperature is an important factor in tissue ischemia. Additional studies examining the relative importance of pressure, shear, and temperature and potential effects of lowering temperature on tissue ischemia in healthy volunteers and

  11. Unusual structures are present in DNA fragments containing super-long Huntingtin CAG repeats.

    Directory of Open Access Journals (Sweden)

    Daniel Duzdevich

    Full Text Available BACKGROUND: In the R6/2 mouse model of Huntington's disease (HD, expansion of the CAG trinucleotide repeat length beyond about 300 repeats induces a novel phenotype associated with a reduction in transcription of the transgene. METHODOLOGY/PRINCIPAL FINDINGS: We analysed the structure of polymerase chain reaction (PCR-generated DNA containing up to 585 CAG repeats using atomic force microscopy (AFM. As the number of CAG repeats increased, an increasing proportion of the DNA molecules exhibited unusual structural features, including convolutions and multiple protrusions. At least some of these features are hairpin loops, as judged by cross-sectional analysis and sensitivity to cleavage by mung bean nuclease. Single-molecule force measurements showed that the convoluted DNA was very resistant to untangling. In vitro replication by PCR was markedly reduced, and TseI restriction enzyme digestion was also hindered by the abnormal DNA structures. However, significantly, the DNA gained sensitivity to cleavage by the Type III restriction-modification enzyme, EcoP15I. CONCLUSIONS/SIGNIFICANCE: "Super-long" CAG repeats are found in a number of neurological diseases and may also appear through CAG repeat instability. We suggest that unusual DNA structures associated with super-long CAG repeats decrease transcriptional efficiency in vitro. We also raise the possibility that if these structures occur in vivo, they may play a role in the aetiology of CAG repeat diseases such as HD.

  12. Repetibilidade da mensuração de imagens das características de carcaça obtidas por ultrassonografia em fêmeas Nelore Repeatability of ultrasound image measurements of carcass traits in Nellore cattle

    Directory of Open Access Journals (Sweden)

    Maria Eugênia Zerlotti Mercadante

    2010-04-01

    Full Text Available Avaliou-se a repetibilidade da mensuração de imagens de ultrassom da área do músculo longissimus dorsi (AOL e das espessuras de gordura subcutânea do lombo (EGL e da garupa (EGG. Imagens de ultrassom tomadas no lombo (entre a 12ª e a 13ª costela e na garupa (entre os músculos gluteus medium e biceps femoris de novilhas Nelore de 14 a 22 meses de idade foram classificadas em aceitáveis, marginais e rejeitáveis. As imagens aceitáveis e marginais foram mensuradas duas vezes por três técnicos em diferentes níveis de treinamento. Foram estimadas as repetibilidades entre e dentro de técnicos por classe de qualidade da imagem, para determinação do efeito da qualidade da imagem e do técnico no valor absoluto da diferença entre a primeira e a segunda mensuração dessas características. A repetibilidade para as imagens aceitáveis foi maior que para imagens marginais, tanto entre como dentro de técnicos. Na análise da diferença absoluta entre a primeira e a segunda interpretação, foram significativos os efeitos de técnico para AOL e EGL e de classe de qualidade da imagem para AOL. Em geral, o técnico com maior experiência apresentou maiores valores de repetibilidade. É recomendável que a mensuração de imagens de animais de mesmo grupo contemporâneo seja feita por um único técnico.The repeatability of ultrasound image measurements of the longissimus dorsi muscle (AOL and of the rumpfat (EGG and backfat (EGL subcutaneous thickness was evaluated. Ultrasound images taken from the back (between 12th and 13th ribs and from the rump (between gluteus medium and biceps femoris muscles of Nelore heifers at 14 and 22 months of age were classified as acceptable, marginal and rejected. The acceptable and marginal images were measured twice by three technicians at different levels of training. It was estimated repeatabilities among and within technicians by class of image quality in order to determine effect of image quality and of

  13. Crowding by a repeating pattern.

    Science.gov (United States)

    Rosen, Sarah; Pelli, Denis G

    2015-01-01

    Theinability to recognize a peripheral target among flankers is called crowding. For a foveal target, crowding can be distinguished from overlap masking by its sparing of detection, linear scaling with eccentricity, and invariance with target size.Crowding depends on the proximity and similarity of the flankers to the target. Flankers that are far from or dissimilar to the target do not crowd it. On a gray page, text whose neighboring letters have different colors, alternately black and white, has enough dissimilarity that it might escape crowding. Since reading speed is normally limited by crowding, escape from crowding should allow faster reading. Yet reading speed is unchanged (Chung & Mansfield, 2009). Why? A recent vernier study found that using alternating-color flankers produces strong crowding (Manassi, Sayim, & Herzog, 2012). Might that effect occur with letters and reading? Critical spacing is the minimum center-to-center target-flanker spacing needed to correctly identify the target. We measure it for a target letter surrounded by several equidistant flanker letters of the same polarity, opposite polarity, or mixed polarity: alternately white and black. We find strong crowding in the alternating condition, even though each flanker letter is beyond its own critical spacing (as measured in a separate condition). Thus a periodic repeating pattern can produce crowding even when the individual elements do not. Further, in all conditions we find that, once a periodic pattern repeats (two cycles), further repetition does not affect critical spacing of the innermost flanker.

  14. A comparison of pairs figure skaters in repeated jumps.

    Science.gov (United States)

    Sands, William A; Kimmel, Wendy L; McNeal, Jeni R; Murray, Steven Ross; Stone, Michael H

    2012-01-01

    Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg) calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA) showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare. Key pointsThe repeated jumps test can account for about 50% of the variance in pairs ranks.Changes in technique are largely due to fatigue, but the athletes were able to maintain a maximum flexion knee angle very close to the desired 90 degrees. Changes in angular velocity and jump heights occurred as expected, again probably due to fatigue.As expected from metabolic information, the athletes' power indexes peak around 20s and decline thereafter. Coaches should be aware of this time as a boundary beyond which fatigue becomes more manifest, and use careful choreographic choices to provide rest periods that are disguised as less demanding skating elements to afford recovery.The repeated jumps test may be a helpful off-ice test of power-endurance for figure skaters.

  15. Polymorphic GGC repeat differentially regulates human reelin gene expression levels.

    Science.gov (United States)

    Persico, A M; Levitt, P; Pimenta, A F

    2006-10-01

    The human gene encoding Reelin (RELN), a pivotal protein in neurodevelopment, includes a polymorphic GGC repeat in its 5' untranslated region (UTR). CHO cells transfected with constructs encompassing the RELN 5'UTR with 4-to-13 GGC repeats upstream of the luciferase reporter gene show declining luciferase activity with increasing GGC repeat number (P autism.

  16. 超高分辨率OCT角膜上皮厚度自动测量的重复性研究%Study of repeatability of corneal epithelium thickness profiles automatically measured by ultra -high resolution OCT system

    Institute of Scientific and Technical Information of China (English)

    徐肃仲; 叶欣杰; 许哲; 杨纯; 沈梅晓

    2013-01-01

    目的:研究基于自动分层算法的超高分辨率谱域 OCT ( UHR-OCT)用于角膜上皮厚度测量的重复性。  方法:使用自行搭建的UHR-OCT系统采集18例健康受试者(年龄23.2±0.9岁)左眼的图像,应用一种基于轴向梯度信息和最短路径的分层算法对得到的SD-OCT图像进行边界探测获取角膜上皮厚度。  结果:自动与手动的上皮分层的位置有很好的相关性(P>0.05,配对t检验)。自动算法获取的6 mm范围平均上皮厚度为52.1±2.1μm,范围从50.3±1.8μm 到53.2±2.4μm,与手动分层之间的角膜上皮厚度差异为0.4±0.3μm。UHR-OCT自动算法重复测量上皮厚度的组内相关系数ICC和可重复性系数CoR分别为0.90±0.05,1.44±0.01μm。  结论:对于超高分辨率OCT,自动分层方法在角膜上皮厚度测量中有着很好的准确性和可重复性。%AIM:To assess the repeatability of thickness profiles of corneal epithelium produced by aautomatic hierarchic algorithm that was applied to images obtained by a custom-built ultra-high resolution OCT ( UHR-OCT ) system. METHODS:Eighteen left eyes of 18 subjects (23.2±0.9) years;mean age±standard deviation) were imaged twice on non-consecutive days by a custom-built ultra-high resolution OCT ( UHR -OCT ) system. A hierarchic algorithm based on the axial gradient information and a shortest path search was developed to measure the corneal epithelial thickness profiles from the SD-OCT images. RESULTS: There was good correlation between theautomatic and manual hierarchy positions of the epithelium ( p >0.05, paired t -test ). The average epithelial thickness of the 6mm central corneal region determined by the automatic hierarchic algorithm was 52.1±2.1μm, ranging from 50.3 ±1.8μm to 53.2 ±2.4μm along the horizontal meridian. The epithelial thickness differences between automatic and manual hierarchy by the UHR-OCT systems were 0.4 ±0

  17. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-01-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  18. A high stability and repeatability electrochemical scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Zhigang; Wang, Jihao; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-12-15

    We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO{sub 4}{sup 2−} image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.

  19. Repeated Measurement of Divers’ Word Fluency.

    Science.gov (United States)

    1987-04-01

    function (Fillskov & Boll, -V 1981). One type of test with clinical significance reflects Word Fluency (Borkowski, Benton & Spreen, 1967; Lezak, 1983). Word...Fluency is "the facility to produce words that fit one or more structural, phonetic , or orthographic restrictions that are not relevant to the meaning...toxic chemical exposure (Anger, 1984) and closed head injury (Borkowski et al, 1967). Word Fluency reflects mild linguistic deficits in expressive speech

  20. Evolution of Determinant Factors of Repeated Sprint Ability.

    Science.gov (United States)

    Pareja-Blanco, Fernando; Suarez-Arrones, Luis; Rodríguez-Rosell, David; López-Segovia, Manuel; Jiménez-Reyes, Pedro; Bachero-Mena, Beatriz; González-Badillo, Juan José

    2016-12-01

    The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA) and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs), a straight-line 30 m sprint (T30), an RSA test (6 x 20 + 20 m with 20 s recovery), a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1) and a 20 m shuttle run test (20mSRT). The mean (RSAmean), the fastest (RSAbest), each single sprint time, and the percentage in a sprint decrease (%Dec) in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82) and with all single sprints (p sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints.

  1. Quantum Key Distribution over Probabilistic Quantum Repeaters

    CERN Document Server

    Amirloo, Jeyran; Majedi, A Hamed

    2010-01-01

    A feasible route towards implementing long-distance quantum key distribution (QKD) systems relies on probabilistic schemes for entanglement distribution and swapping as proposed in the work of Duan, Lukin, Cirac, and Zoller (DLCZ) [Nature 414, 413 (2001)]. Here, we calculate the conditional throughput and fidelity of entanglement for DLCZ quantum repeaters, by accounting for the DLCZ self-purification property, in the presence of multiple excitations in the ensemble memories as well as loss and other sources of inefficiency in the channel and measurement modules. We then use our results to find the generation rate of secure key bits for QKD systems that rely on DLCZ quantum repeaters. We compare the key generation rate per logical memory employed in the two cases of with and without a repeater node. We find the cross-over distance beyond which the repeater system outperforms the non-repeater one. That provides us with the optimum inter-node distancing in quantum repeater systems. We also find the optimal exci...

  2. The Great Cometary Show

    Science.gov (United States)

    2007-01-01

    its high spatial and spectral resolution, it was possible to zoom into the very heart of this very massive star. In this innermost region, the observations are dominated by the extremely dense stellar wind that totally obscures the underlying central star. The AMBER observations show that this dense stellar wind is not spherically symmetric, but exhibits a clearly elongated structure. Overall, the AMBER observations confirm that the extremely high mass loss of Eta Carinae's massive central star is non-spherical and much stronger along the poles than in the equatorial plane. This is in agreement with theoretical models that predict such an enhanced polar mass-loss in the case of rapidly rotating stars. ESO PR Photo 06c/07 ESO PR Photo 06c/07 RS Ophiuchi in Outburst Several papers from this special feature focus on the later stages in a star's life. One looks at the binary system Gamma 2 Velorum, which contains the closest example of a star known as a Wolf-Rayet. A single AMBER observation allowed the astronomers to separate the spectra of the two components, offering new insights in the modeling of Wolf-Rayet stars, but made it also possible to measure the separation between the two stars. This led to a new determination of the distance of the system, showing that previous estimates were incorrect. The observations also revealed information on the region where the winds from the two stars collide. The famous binary system RS Ophiuchi, an example of a recurrent nova, was observed just 5 days after it was discovered to be in outburst on 12 February 2006, an event that has been expected for 21 years. AMBER was able to detect the extension of the expanding nova emission. These observations show a complex geometry and kinematics, far from the simple interpretation of a spherical fireball in extension. AMBER has detected a high velocity jet probably perpendicular to the orbital plane of the binary system, and allowed a precise and careful study of the wind and the shockwave

  3. Remarkable selective constraints on exonic dinucleotide repeats.

    Science.gov (United States)

    Haasl, Ryan J; Payseur, Bret A

    2014-09-01

    Long dinucleotide repeats found in exons present a substantial mutational hazard: mutations at these loci occur often and generate frameshifts. Here, we provide clear and compelling evidence that exonic dinucleotides experience strong selective constraint. In humans, only 18 exonic dinucleotides have repeat lengths greater than six, which contrasts sharply with the genome-wide distribution of dinucleotides. We genotyped each of these dinucleotides in 200 humans from eight 1000 Genomes Project populations and found a near-absence of polymorphism. More remarkably, divergence data demonstrate that repeat lengths have been conserved across the primate phylogeny in spite of what is likely considerable mutational pressure. Coalescent simulations show that even a very low mutation rate at these loci fails to explain the anomalous patterns of polymorphism and divergence. Our data support two related selective constraints on the evolution of exonic dinucleotides: a short-term intolerance for any change to repeat length and a long-term prevention of increases to repeat length. In general, our results implicate purifying selection as the force that eliminates new, deleterious mutants at exonic dinucleotides. We briefly discuss the evolution of the longest exonic dinucleotide in the human genome--a 10 x CA repeat in fibroblast growth factor receptor-like 1 (FGFRL1)--that should possess a considerably greater mutation rate than any other exonic dinucleotide and therefore generate a large number of deleterious variants. © 2014 The Author(s). Evolution © 2014 The Society for the Study of Evolution.

  4. Dynamic combinatorial libraries of artificial repeat proteins.

    Science.gov (United States)

    Eisenberg, Margarita; Shumacher, Inbal; Cohen-Luria, Rivka; Ashkenasy, Gonen

    2013-06-15

    Repeat proteins are found in almost all cellular systems, where they are involved in diverse molecular recognition processes. Recent studies have suggested that de novo designed repeat proteins may serve as universal binders, and might potentially be used as practical alternative to antibodies. We describe here a novel chemical methodology for producing small libraries of repeat proteins, and screening in parallel the ligand binding of library members. The first stage of this research involved the total synthesis of a consensus-based three-repeat tetratricopeptide (TPR) protein (~14 kDa), via sequential attachment of the respective peptides. Despite the effectiveness of the synthesis and ligation steps, this method was found to be too demanding for the production of proteins containing variable number of repeats. Additionally, the analysis of binding of the individual proteins was time consuming. Therefore, we designed and prepared novel dynamic combinatorial libraries (DCLs), and show that their equilibration can facilitate the formation of TPR proteins containing up to eight repeating units. Interestingly, equilibration of the library building blocks in the presence of the biologically relevant ligands, Hsp90 and Hsp70, induced their oligomerization into forming more of the proteins with large recognition surfaces. We suggest that this work presents a novel simple and rapid tool for the simultaneous screening of protein mixtures with variable binding surfaces, and for identifying new binders for ligands of interest.

  5. Studies of an expanded trinucleotide repeat in transgenic mice

    Energy Technology Data Exchange (ETDEWEB)

    Bingham, P.; Wang, S.; Merry, D. [Univ. of Pennsylvania, Philadelphia, PA (United States)

    1994-09-01

    Spinal and bulbar muscular atrophy (SBMA) is a progressive motor neuron disease caused by expansion of a trinucleotide repeat in the androgen receptor gene (AR{sup exp}). AR{sup exp} repeats expand further or contract in approximately 25% of transmissions. Analogous {open_quotes}dynamic mutations{close_quotes} have been reported in other expanded trinucleotide repeat disorders. We have been developing a mouse model of this disease using a transgenic approach. Expression of the SBMA AR was documented in transgenic mice with an inducible promoter. No phenotypic effects of transgene expression were observed. We have extended our previous results on stability of the expanded trinucleotide repeat in transgenic mice in two lines carrying AR{sup exp}. Tail DNA was amplified by PCR using primers spanning the repeat on 60 AR{sup exp} transgenic mice from four different transgenic lines. Migration of the PCR product through an acrylamide gel showed no change of the 45 CAG repeat length in any progeny. Similarly, PCR products from 23 normal repeat transgenics showed no change from the repeat length of the original construct. Unlike the disease allele in humans, the expanded repeat AR cDNA in transgenic mice showed no change in repeat length with transmission. The relative stability of CAG repeats seen in the transgenic mice may indicate either differences in the fidelity of replicative enzymes, or differences in error identification and repair between mice and humans. Integration site or structural properties of the transgene itself might also play a role.

  6. Verificação da prótese auditiva realizada face a face e via teleconsulta: medidas repetidas Telecounselling and face to face hearing aid verification: repeated measures

    Directory of Open Access Journals (Sweden)

    Deborah Viviane Ferrari

    2012-12-01

    Full Text Available OBJETIVO: avaliar as medidas repetidas da resposta de ressonância da orelha externa sem (REUR e com uso de amplificação (REAR e o ganho de inserção (REIG, realizados face a face e via teleconsulta. MÉTODO: estudo prospectivo longitudinal. Foram realizadas quatro repetições da REUR, REAR e REIG (com estímulo speech noise apresentado em 65 dB NPS e 0º azimute em 19 orelhas de adultos ouvintes normais, via face a face (F e teleconsulta síncrona por controle remoto de aplicativo (T e vídeo interativo. O software Polycom PVX foi utilizado para compartilhamento e transmissão de áudio e vídeo. A conexão foi realizada via LAN (Local Area Network USP na velocidade de 384 kbps Foi calculado o erro causal (Dalhberg entre as quatro medidas para frequências de 250 a 8000 Hz. RESULTADOS: os erros casuais entre as medidas F e T foram muito semelhantes, sendo maiores nas frequências acima de 4 kHz. As diferenças e variações entre as medidas F e T estavam dentro da magnitude de variabilidade do procedimento de medidas com microfone sonda. CONCLUSÃO: as medidas com microfone sonda via teleconsulta fornece resultados confiáveis e similares aos obtidos pelo procedimento padrão.PURPOSE: to evaluate the repeated measurements of the real ear unaided response (REUR, real ear aided response (REAR and insertion gain (REIG conducted as face to face (F and via telecounselling (T. METHOD: longitudinal prospective study. Four measures of REUR, REAR and REIG (carried out with speech noise stimulus presented at 65 dB SPL at 0° azimuth were obtained in 19 ears in normal hearing adults, face to face and via synchronous telecounsellings with remote control of the real ear equipment and interactive video. Polycom PVX software was used for desktop sharing and video and audio transmission. The Loca Area Network (LAN USP was used for the connection (transmission rate: 384 kbps. Dahlberg’s casual errors were calculated for obtaining the measures for

  7. Effect of repeated morphine withdrawal on spatial learning, memory and serum cortisol level in mice

    Directory of Open Access Journals (Sweden)

    Mahdieh Matinfar

    2013-01-01

    Full Text Available Background: One of the serious problems that opioid addicted people are facing is repeated withdrawal syndrome that is accompanying with a significant stress load for addicts. Therefore, the aim of this study was to evaluate the effects of repeated withdrawal on spatial learning, memory and serum cortisol levels in morphine-dependent mice. Materials and Methods: Male NMRI mice received morphine as daily increasing doses for 3 days. After that, the mice underwent one time or repeated spontaneous or pharmacologic (naloxone-precipitated withdrawal. Then spatial learning and memory were investigated by morris water maze test, and at the end trunk blood samples were collected for measurement of serum cortisol levels. Results: The results showed that only repeated spontaneous withdrawal significantly increases escape latency ( P < 0.05, and in other models of withdrawal, spatial learning and memory were intact. The results of probe trial were intact in all groups. Radioimmunoassay showed that serum cortisol levels were increased significantly in all models of withdrawal ( P < 0.05 and P < 0.01 except the repeated spontaneous withdrawal. Conclusion: The results showed that short periods of withdrawal syndrome can increase serum cortisol levels; however they do not affect spatial learning and memory. Nevertheless, repeated spontaneous withdrawal can make learning slow.

  8. The Health Show

    OpenAIRE

    Swann, David

    2011-01-01

    Dr David Swann interviewed on The Health Show, Series 1, Episode 5, 2011 for BBC World about the award-winning 21st Century Nursing Bag. BBC World News reaches 241million people every week, available in 296 million homes, 1.8 million hotel rooms and has the highest average viewership on a weekday of any international news channel. The Health Show is a new 26-part series for BBC World News covering the most important news stories from around the world.

  9. Two-dimensional quantum repeaters

    Science.gov (United States)

    Wallnöfer, J.; Zwerger, M.; Muschik, C.; Sangouard, N.; Dür, W.

    2016-11-01

    The endeavor to develop quantum networks gave rise to a rapidly developing field with far-reaching applications such as secure communication and the realization of distributed computing tasks. This ultimately calls for the creation of flexible multiuser structures that allow for quantum communication between arbitrary pairs of parties in the network and facilitate also multiuser applications. To address this challenge, we propose a two-dimensional quantum repeater architecture to establish long-distance entanglement shared between multiple communication partners in the presence of channel noise and imperfect local control operations. The scheme is based on the creation of self-similar multiqubit entanglement structures at growing scale, where variants of entanglement swapping and multiparty entanglement purification are combined to create high-fidelity entangled states. We show how such networks can be implemented using trapped ions in cavities.

  10. Optimal and safe treatment of spider leg veins measuring less than 1.5 mm on skin type IV patients, using repeated low-fluence Nd:YAG laser pulses after polidocanol injection.

    Science.gov (United States)

    Moreno-Moraga, Javier; Hernández, Esteban; Royo, Josefina; Alcolea, Justo; Isarría, M Jose; Pascu, Mihail Lucian; Smarandache, Adriana; Trelles, Mario

    2013-05-01

    Treatment of micro-veins of less than 1.5 mm with laser and with chemical sclerosis is technically challenging because of their difficulty to remedy. Laser treatment is even more difficult when dark phototypes are involved.Three groups of 30 patients each, skin type IV, and vessels measuring less than 1.5 mm in diameter, were enrolled for two treatment sessions 8 weeks apart: group A, polidocanol (POL) micro-foam injection; group B, Nd:YAG laser alone; and group C, laser after POL injection. Repeated 8-Hz low-fluence pulses, moving the hand piece over a 3-cm vein segment with an average of five laser passes maximum and with a total time irradiation of 1 s were used. Sixteen weeks after the second treatment, statistically, degree of clearance after examining photographs and patients satisfaction index, plotted on a visual analogue scale and comparing results of all three groups, results were significantly better for group C (p<0.0001). No significant differences in complications were noticed between the three groups. Efficacy of combining POL and laser proved safe and satisfactory in 96 % of patients using low-fluence laser pulses with a total cumulative energy in the 3 cm venous segment, lower than that of conventional treatment. Very few and transient complications were observed. POL foam injection followed by laser pulses is safe and efficient for vein treatment in dark-skinned patients.

  11. Talking about the cause of the failures to prohibit repeatedly for prostitution or whoring and its measures%当前卖淫嫖娼屡禁不止的原因及对策

    Institute of Scientific and Technical Information of China (English)

    冯文林

    2011-01-01

    The author was talking about the characteristics of the prostitution and whoring in current, setting forth the cause of the failures to prohibit repeatedly for the prostitution and whoring. At last, the author was putting forward to the controlling measur%随着社会主义市场经济的快速发展,许多人的思想观念受市场经济消极因素和西方资本主义腐朽思想及生活方式的影响进一步加深,卖淫嫖娼行为逐年增多,已经成为一种广泛的社会丑恶现象,严重影响到当前社会治安秩序的和谐稳定,引发一系列的问题,其危害性不可低估。政府和公安机关要加大对卖淫嫖娼行为的查处打击力度,研究如何才能减少滋生卖淫嫖娼的各种因素,加强预防和正面宣传,有针对性的开展治理,净化社会环境,维护社会和谐稳定。

  12. A Fashion Show

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    <正>Story: The yearly fashion show day.The children take turns to walk on the stage and show the class their favorite clothes.Now it’s Joe’s and Phoebe’s turn.Joe walks on the stage and says,“My shorts are blue.Do you like my blue shorts?”On the other side of the stage, Phoebe is wearing her favorite pink skirt.“My skirt is pink.Do you like my pink skirt?”asks

  13. The excess of small inverted repeats in prokaryotes.

    Science.gov (United States)

    Ladoukakis, Emmanuel D; Eyre-Walker, Adam

    2008-09-01

    Recent analyses have shown that there is a large excess of perfect inverted repeats in many prokaryotic genomes but not in eukaryotic ones. This difference could be due to a genuine difference between prokaryotes and eukaryotes or to differences in the methods and types of data analyzed--full genome versus protein coding sequences. We used simulations to show that the method used previously tends to underestimate the expected number of inverted repeats. However, this bias is not large and cannot explain the excess of inverted repeats observed in real data. In contrast, our method is unbiased. When both methods are applied to bacterial protein coding sequences they both detect an excess of inverted repeats, which is much lower than previously reported in whole prokaryotic genomes. This suggests that the reported large excess of inverted repeats is due to repeats found in intergenic regions. These repeats could be due to transcription factor binding sites, or other types of repetitive DNA, on opposite strands of the DNA sequence. In contrast, the smaller, but significant, excess of inverted repeats that we report in protein coding sequences may be due to sequence-directed mutagenesis (SDM). SDM is a process where one copy of a small, imperfect, inverted repeat corrects the other copy via strand misalignment, resulting in a perfect repeat and a series of mutations. We show by simulation that even very low levels of SDM, relative to the rate of point mutation, can generate a substantial excess of inverted repeats.

  14. On not showing scalps

    DEFF Research Database (Denmark)

    Marselis, Randi Lorenz

    2016-01-01

    proposed by Janet Marstine, the editor of the Routledge Companion to Museum Ethics, I show how the museum succeeded in engaging users in questions of museum ethics. However, this specific debate on human remains in museums developed into an encounter between a global, museological discourse...

  15. Honored Teacher Shows Commitment.

    Science.gov (United States)

    Ratte, Kathy

    1987-01-01

    Part of the acceptance speech of the 1985 National Council for the Social Studies Teacher of the Year, this article describes the censorship experience of this honored social studies teacher. The incident involved the showing of a videotape version of the feature film entitled "The Seduction of Joe Tynan." (JDH)

  16. A Visionary Show

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Seduction. Distinction. Relax. Pulsation. These are the "style universes" on display at Première Vision, heralded as "The World’s Premiere Fabric Show." Started more than 35 years ago by 15 French weavers, Première Vision has expanded beyond its

  17. Honored Teacher Shows Commitment.

    Science.gov (United States)

    Ratte, Kathy

    1987-01-01

    Part of the acceptance speech of the 1985 National Council for the Social Studies Teacher of the Year, this article describes the censorship experience of this honored social studies teacher. The incident involved the showing of a videotape version of the feature film entitled "The Seduction of Joe Tynan." (JDH)

  18. Repeatability of phasic muscle activity: performance of surface and intramuscular wire electrodes in gait analysis.

    Science.gov (United States)

    Kadaba, M P; Wootten, M E; Gainey, J; Cochran, G V

    1985-01-01

    Repeatability is an important consideration for gait analysis data that are being used as an adjunct to clinical decision making. An index of repeatability may be based on a statistical criterion (variance ratio) that reflects similarity of wave forms over a number of identical cycles. The purpose of this study was to use the variance ratio to assess the repeatability of phasic muscle activity recorded with surface and bipolar intramuscular wire electrodes during gait on 10 normal subjects. Variance ratios were calculated using rectified and smoothed electromyographic data recorded simultaneously from the two types of electrodes. Three measures of repeatability (reproducibility, reliability, and constancy--defined as the cycle-to-cycle, run-to-run, and day-to-day repeatability of phasic muscle activity) were used to compare the performance of the two electrode techniques. Results show that the reproducibility and reliability were better for surface electrodes than for intramuscular wire electrodes, and constancy was good for surface electrodes and poor for intramuscular wire electrodes. Repeatability improved with increasing smoothing window lengths but was better for surface electrodes than wire electrodes, irrespective of the smoothing window. This study indicates that surface electrode data represent a more consistent measure of activity of superficial muscles, if comparisons are to be made between gait data from different test days.

  19. Quality control during repeated fryings

    Directory of Open Access Journals (Sweden)

    Cuesta, C.

    1998-08-01

    Full Text Available Most of the debate ¡s about how the slow or frequent turnover of fresh fat affects the deterioration, of fat used in frying. Then, the modification of different oils used in repeated fryings of potatoes without or with turnover of fresh oil, under similar frying conditions, was evaluated by two criteria: by measuring the total polar component isolated by column chromatography and by the evaluation of the specific compounds related to thermoxidative and hydrolytic alteration by High Performance Size Exclusion Chromatography (HPSEC. The results indicate that with frequent turnover of fresh oil, the critical level of 25% of polar material is rarely reached, and there are fewer problems with fat deterioration because the frying tended to increase the level of polar material and thermoxidative compounds (polymers and dimers of triglycerides and oxidized triglycerides in the fryer oil during the first fryings, followed by minor changes and a tendency to reach a near-steady state in successive fryings. However, in repeated frying of potatoes using a null turnover the alteration rate was higher being linear the relationship found between polar material or the different thermoxidative compounds and the number of fryings. On the other hand chemical reactions produced during deep-fat frying can be minimized by using proper oils. In addition the increased level of consumers awareness toward fat composition and its impact on human health could had an impact on the selection of fats for snacks and for industry. In this way monoenic fats are the most adequate from a nutritional point of view and for its oxidative stability during frying.

  20. Developmental Change in Fetal Response to Repeated Low-Intensity Sound

    Science.gov (United States)

    Morokuma, Seiichi; Doria, Valentina; Ierullo, Antonio; Kinukawa, Naoko; Fukushima, Kotaro; Nakano, Hitoo; Arulkumaran, Sabaratnam; Papageorghiou, Aris T.

    2008-01-01

    The aim of this study was to investigate developmental changes in heart rate response to repeated low-intensity (85 dB) sound stimulation in fetuses between 32 and 37 weeks of gestation. We measured amplitude changes in heart rate as our index of fetal response. At 35 to 37 weeks of gestation, the majority of fetuses showed a deceleratory response…

  1. A Repeated Signal Difference for Recognising Patterns

    Directory of Open Access Journals (Sweden)

    Kieran Greer

    2016-08-01

    Full Text Available This paper describes a new mechanism that might help with defining pattern sequences, by the fact that it can produce an upper bound on the ensemble value that can persistently oscillate with the actual values produced from each pattern. With every firing event, a node also receives an on/off feedback switch. If the node fires then it sends a feedback result depending on the input signal strength. If the input signal is positive or larger, it can store an ‘on’ switch feedback for the next iteration. If the signal is negative or smaller it can store an ‘off’ switch feedback for the next iteration. If the node does not fire, then it does not affect the current feedback situation and receives the switch command produced by the last active pattern event for the same neuron. The upper bound therefore also represents the largest or most enclosing pattern set and the lower value is for the actual set of firing patterns. If the pattern sequence repeats, it will oscillate between the two values, allowing them to be recognised and measured more easily, over time. Tests show that changing the sequence ordering produces different value sets, which can also be measured.

  2. Shanghai Shows Its Heart

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The city known as China’s economic powerhouse showed a more caring face as host of the Special Olympic Games Between October 2 and 11,the Special Olympics Summer Games were hosted in Shanghai,the first time the 40-year-old athletic com- petition for people with intellectual disabilities came to a developing country. This Special Olympics was also larger than all previous games in temps of the number of athletes.

  3. DWI Repeaters and Non-Repeaters: A Comparison.

    Science.gov (United States)

    Weeber, Stan

    1981-01-01

    Discussed how driving-while-intoxicated (DWI) repeaters differed signigicantly from nonrepeaters on 4 of 23 variables tested. Repeaters were more likely to have zero or two dependent children, attend church frequently, drink occasionally and have one or more arrests for public intoxication. (Author)

  4. To Repeat or Not to Repeat a Course

    Science.gov (United States)

    Armstrong, Michael J.; Biktimirov, Ernest N.

    2013-01-01

    The difficult transition from high school to university means that many students need to repeat (retake) 1 or more of their university courses. The authors examine the performance of students repeating first-year core courses in an undergraduate business program. They used data from university records for 116 students who took a total of 232…

  5. Application of UAV-SfM photogrammetry and aerial lidar to a disastrous flood: repeated topographic measurement of a newly formed crevasse splay of the Kinu River, central Japan

    Science.gov (United States)

    Izumida, Atsuto; Uchiyama, Shoichiro; Sugai, Toshihiko

    2017-09-01

    Geomorphic impacts of a disastrous crevasse splay that formed in September 2015 and its post-formation modifications were quantitatively documented by using repeated, high-definition digital surface models (DSMs) of an inhabited and cultivated floodplain of the Kinu River, central Japan. The DSMs were based on pre-flood (resolution: 2 m) and post-flood (resolution: 1 m) aerial light detection and ranging (lidar) data from January 2007 and September 2015, respectively, and on structure-from-motion (SfM) photogrammetry data (resolution: 3.84 cm) derived from aerial photos taken by an unmanned aerial vehicle (UAV) in December 2015. After elimination of systematic errors among the DSMs and down-sampling of the SfM-derived DSM, elevation changes on the order of 10-1 m - including not only topography but also growth of vegetation, vanishing of flood waters, and restoration and repair works - were detected. Comparison of the DSMs showed that the volume eroded by the flood was more than twice the deposited volume in the area within 300-500 m of the breached artificial levee, where the topography was significantly affected. The results suggest that DSMs based on a combination of UAV-SfM and lidar data can be used to quantify, rapidly and in rich detail, topographic changes on floodplains caused by floods.

  6. Costly renegotiation in repeated Bertand games

    DEFF Research Database (Denmark)

    Andersson, Ola; Wengström, Erik Roland

    2010-01-01

    This paper extends the concept of weak renegotiation-proof equilibrium (WRP) to allow for costly renegotiation and shows that even small renegotiation costs can have dramatic effects on the set of equilibria. More specifically, the paper analyzes the infinitely repeated Bertrand game. It is shown...

  7. Costly renegotiation in repeated Bertand games

    DEFF Research Database (Denmark)

    Andersson, Ola; Wengström, Erik Roland

    2010-01-01

    This paper extends the concept of weak renegotiation-proof equilibrium (WRP) to allow for costly renegotiation and shows that even small renegotiation costs can have dramatic effects on the set of equilibria. More specifically, the paper analyzes the infinitely repeated Bertrand game. It is shown...

  8. Not a "reality" show.

    Science.gov (United States)

    Wrong, Terence; Baumgart, Erica

    2013-01-01

    The authors of the preceding articles raise legitimate questions about patient and staff rights and the unintended consequences of allowing ABC News to film inside teaching hospitals. We explain why we regard their fears as baseless and not supported by what we heard from individuals portrayed in the filming, our decade-long experience making medical documentaries, and the full un-aired context of the scenes shown in the broadcast. The authors don't and can't know what conversations we had, what documents we reviewed, and what protections we put in place in each televised scene. Finally, we hope to correct several misleading examples cited by the authors as well as their offhand mischaracterization of our program as a "reality" show.

  9. Repeated Nrf2 stimulation using sulforaphane protects fibroblasts from ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Sherin T.; Bergström, Petra; Hammarsten, Ola, E-mail: ola.hammarsten@clinchem.gu.se

    2014-05-01

    Most of the cytotoxicity induced by ionizing radiation is mediated by radical-induced DNA double-strand breaks. Cellular protection from free radicals can be stimulated several fold by sulforaphane-mediated activation of the transcription factor Nrf2 that regulates more than 50 genes involved in the detoxification of reactive substances and radicals. Here, we report that repeated sulforaphane treatment increases radioresistance in primary human skin fibroblasts. Cells were either treated with sulforaphane for four hours once or with four-hour treatments repeatedly for three consecutive days prior to radiation exposure. Fibroblasts exposed to repeated-sulforaphane treatment showed a more pronounced dose-dependent induction of Nrf2-regulated mRNA and reduced amount of radiation-induced free radicals compared with cells treated once with sulforaphane. In addition, radiation- induced DNA double-strand breaks measured by gamma-H2AX foci were attenuated following repeated sulforaphane treatment. As a result, cellular protection from ionizing radiation measured by the 5-ethynyl-2′-deoxyuridine (EdU) assay was increased, specifically in cells exposed to repeated sulforaphane treatment. Sulforaphane treatment was unable to protect Nrf2 knockout mouse embryonic fibroblasts, indicating that the sulforaphane-induced radioprotection was Nrf2-dependent. Moreover, radioprotection by repeated sulforaphane treatment was dose-dependent with an optimal effect at 10 uM, whereas both lower and higher concentrations resulted in lower levels of radioprotection. Our data indicate that the Nrf2 system can be trained to provide further protection from radical damage. - Highlights: • Repeated treatment with sulforaphane protects fibroblasts from ionizing radiation • Repeated sulforaphane treatment attenuates radiation induced ROS and DNA damage • Sulforaphane mediated protection is Nrf2 dependent.

  10. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  11. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  12. Showing Value (Editorial

    Directory of Open Access Journals (Sweden)

    Denise Koufogiannakis

    2009-06-01

    Full Text Available When Su Cleyle and I first decided to start Evidence Based Library and Information Practice, one of the things we agreed upon immediately was that the journal be open access. We knew that a major obstacle to librarians using the research literature was that they did not have access to the research literature. Although Su and I are both academic librarians who can access a wide variety of library and information literature from our institutions, we belong to a profession where not everyone has equal access to the research in our field. Without such access to our own body of literature, how can we ever hope for practitioners to use research evidence in their decision making? It would have been contradictory to the principles of evidence based library and information practice to do otherwise.One of the specific groups we thought could use such an open access venue for discovering research literature was school librarians. School librarians are often isolated and lacking access to the research literature that may help them prove to stakeholders the importance of their libraries and their role within schools. Certainly, school libraries have been in decline and the use of evidence to show value is needed. As Ken Haycock noted in his 2003 report, The Crisis in Canada’s School Libraries: The Case for Reform and Reinvestment, “Across the country, teacher-librarians are losing their jobs or being reassigned. Collections are becoming depleted owing to budget cuts. Some principals believe that in the age of the Internet and the classroom workstation, the school library is an artifact” (9. Within this context, school librarians are looking to our research literature for evidence of the impact that school library programs have on learning outcomes and student success. They are integrating that evidence into their practice, and reflecting upon what can be improved locally. They are focusing on students and showing the impact of school libraries and

  13. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    and total physical activity, moderate-to-vigorous physical activity and sleep duration (boys only) were lower during weekends at all seasons (P ≤ 0.01). Intraclass correlation coefficients between seasons ranged from 0.47-0.74, leaving 45-78% to seasonal variation. CONCLUSIONS: Overall, sedentary time...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... was higher and physical activity lower during winter and during weekends. The most accurate and unbiased estimates of physical activity came from autumn; however, the considerable intra-individual variation suggests that a single measurement may not adequately characterise children’s habitual sleep...

  14. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim

    2013-01-01

    was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...... to missing data, 730 children were included in the current analytical sample. An accelerometer was worn for 7 days and 8 nights during autumn, winter and spring, from which physical activity, sedentary time and sleep duration were measured. Cardio-respiratory fitness was assessed using a 10-min intermittent...... running test. RESULTS: The children had 5% more sedentary time, 23% less time in moderate-to-vigorous physical activity and 2% longer sleep duration during winter compared to spring and cardio-respiratory fitness was 4% higher during spring compared to autumn (P Sedentary time was higher...

  15. Public medical shows.

    Science.gov (United States)

    Walusinski, Olivier

    2014-01-01

    In the second half of the 19th century, Jean-Martin Charcot (1825-1893) became famous for the quality of his teaching and his innovative neurological discoveries, bringing many French and foreign students to Paris. A hunger for recognition, together with progressive and anticlerical ideals, led Charcot to invite writers, journalists, and politicians to his lessons, during which he presented the results of his work on hysteria. These events became public performances, for which physicians and patients were transformed into actors. Major newspapers ran accounts of these consultations, more like theatrical shows in some respects. The resultant enthusiasm prompted other physicians in Paris and throughout France to try and imitate them. We will compare the form and substance of Charcot's lessons with those given by Jules-Bernard Luys (1828-1897), Victor Dumontpallier (1826-1899), Ambroise-Auguste Liébault (1823-1904), Hippolyte Bernheim (1840-1919), Joseph Grasset (1849-1918), and Albert Pitres (1848-1928). We will also note their impact on contemporary cinema and theatre.

  16. 重複觀測量數之分析:多群體多變項線性成長模式的估計Data Analysis of Repeated Measures: Estimating a Multi-Group Multivariate Linear Growth Model

    Directory of Open Access Journals (Sweden)

    溫福星 Fur-Hsing Wen

    2012-03-01

    Full Text Available 本研究利用「台灣教育長期追蹤資料庫」的一般分析能力與數學分析能力的四波調查結果,配合男、女學生樣本進行多群體多條追蹤資料的線性成長模式估計。在考慮重複觀測資料誤差項在不同時點的變異數非同質與不同時點間的共變數非獨立情況下,以及男、女學生的不同成長軌跡,將誤差項結構設為無限制結構,利用虛擬變項交互項法與虛擬變項多樣本法同時估計不同性別、不同能力的線性成長軌跡變化。由於全部追蹤資料樣本存在遺失值的情形,本研究以階層線性模式(hierarchical linear modeling, HLM)軟體對完整資料2,806位學生進行分析,其估計結果發現,在完整資料的兩條成長軌跡模式中,男、女學生誤差項共變異數矩陣結構相同,但線性成長軌跡不恆等。除此之外,本文並對競爭模式比較的結果在文章最後進行討論並提出相關的建議。 This paper demonstrates the data analysis of the repeated measures from the Taiwan Education Panel Survey (TEPS. Based on the four data waves on the TEPS, we consider two abilities (general and mathematic and two population groups (male and female students to construct a multi-group multivariate linear growth model. Because the two-group multivariate repeated measures belong to the different populations and the different research variables, the residual terms of linear growth models may imply heterogeneity of the error covariance structure. We treat the error covariance structure as an unrestricted structure to compare the various types of models. The results from the HLM on the complete data (2,806 students reveal that the male and female students in this study have the same error covariance structure but have distinct linear growth trajectories. In addition, comparisons of the competitive models and related suggestions are discussed in the results and conclusion

  17. Repeated sprint training in normobaric hypoxia.

    Science.gov (United States)

    Galvin, Harvey M; Cooke, Karl; Sumners, David P; Mileva, Katya N; Bowtell, Joanna L

    2013-12-01

    Repeated sprint ability (RSA) is a critical success factor for intermittent sport performance. Repeated sprint training has been shown to improve RSA, we hypothesised that hypoxia would augment these training adaptations. Thirty male well-trained academy rugby union and rugby league players (18.4 ± 1.5 years, 1.83 ± 0.07 m, 88.1 ± 8.9 kg) participated in this single-blind repeated sprint training study. Participants completed 12 sessions of repeated sprint training (10 × 6 s, 30 s recovery) over 4 weeks in either hypoxia (13% FiO₂) or normoxia (21% FiO₂). Pretraining and post-training, participants completed sports specific endurance and sprint field tests and a 10 × 6 s RSA test on a non-motorised treadmill while measuring speed, heart rate, capillary blood lactate, muscle and cerebral deoxygenation and respiratory measures. Yo-Yo Intermittent Recovery Level 1 test performance improved after RS training in both groups, but gains were significantly greater in the hypoxic (33 ± 12%) than the normoxic group (14 ± 10%, prepeated aerobic high intensity workout than an equivalent normoxic training. Performance gains are evident in the short term (4 weeks), a period similar to a preseason training block.

  18. A repeated-measures analysis of the effects of soft tissues on wrist range of motion in the extant phylogenetic bracket of dinosaurs: Implications for the functional origins of an automatic wrist folding mechanism in Crocodilia.

    Science.gov (United States)

    Hutson, Joel David; Hutson, Kelda Nadine

    2014-07-01

    A recent study hypothesized that avian-like wrist folding in quadrupedal dinosaurs could have aided their distinctive style of locomotion with semi-pronated and therefore medially facing palms. However, soft tissues that automatically guide avian wrist folding rarely fossilize, and automatic wrist folding of unknown function in extant crocodilians has not been used to test this hypothesis. Therefore, an investigation of the relative contributions of soft tissues to wrist range of motion (ROM) in the extant phylogenetic bracket of dinosaurs, and the quadrupedal function of crocodilian wrist folding, could inform these questions. Here, we repeatedly measured wrist ROM in degrees through fully fleshed, skinned, minus muscles/tendons, minus ligaments, and skeletonized stages in the American alligator Alligator mississippiensis and the ostrich Struthio camelus. The effects of dissection treatment and observer were statistically significant for alligator wrist folding and ostrich wrist flexion, but not ostrich wrist folding. Final skeletonized wrist folding ROM was higher than (ostrich) or equivalent to (alligator) initial fully fleshed ROM, while final ROM was lower than initial ROM for ostrich wrist flexion. These findings suggest that, unlike the hinge/ball and socket-type elbow and shoulder joints in these archosaurs, ROM within gliding/planar diarthrotic joints is more restricted to the extent of articular surfaces. The alligator data indicate that the crocodilian wrist mechanism functions to automatically lock their semi-pronated palms into a rigid column, which supports the hypothesis that this palmar orientation necessitated soft tissue stiffening mechanisms in certain dinosaurs, although ROM-restricted articulations argue against the presence of an extensive automatic mechanism. Anat Rec, 297:1228-1249, 2014. © 2014 Wiley Periodicals, Inc.

  19. Repeats in transforming acidic coiled-coil (TACC) genes.

    Science.gov (United States)

    Trivedi, Seema

    2013-06-01

    Transforming acidic coiled-coil proteins (TACC1, 2, and 3) are essential proteins associated with the assembly of spindle microtubules and maintenance of bipolarity. Dysregulation of TACCs is associated with tumorigenesis, but studies of microsatellite instability in TACC genes have not been extensive. Microsatellite or simple sequence repeat instability is known to cause many types of cancer. The present in silico analysis of SSRs in human TACC gene sequences shows the presence of mono- to hexa-nucleotide repeats, with the highest densities found for mono- and di-nucleotide repeats. Density of repeats is higher in introns than in exons. Some of the repeats are present in regulatory regions and retained introns. Human TACC genes show conservation of many repeat classes. Microsatellites in TACC genes could be valuable markers for monitoring numerical chromosomal aberrations and or cancer.

  20. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  1. Effect of Repeated Simulations by Standardized Patients on Intercase Reliability.

    Science.gov (United States)

    Colliver, Jerry A.; And Others

    1991-01-01

    A study using five Southern Illinois University senior medical school classes (n=350 students) investigated whether having a standardized patient simulate a case repeatedly in postclerkship medical student evaluation affects the measure's reliability. Results suggest that repeated simulation had little or no effect on intercase reliability of…

  2. CRISPR Recognition Tool (CRT): a tool for automatic detection ofclustered regularly interspaced palindromic repeats

    Energy Technology Data Exchange (ETDEWEB)

    Bland, Charles; Ramsey, Teresa L.; Sabree, Fareedah; Lowe,Micheal; Brown, Kyndall; Kyrpides, Nikos C.; Hugenholtz, Philip

    2007-05-01

    Clustered Regularly Interspaced Palindromic Repeats (CRISPRs) are a novel type of direct repeat found in a wide range of bacteria and archaea. CRISPRs are beginning to attract attention because of their proposed mechanism; that is, defending their hosts against invading extrachromosomal elements such as viruses. Existing repeat detection tools do a poor job of identifying CRISPRs due to the presence of unique spacer sequences separating the repeats. In this study, a new tool, CRT, is introduced that rapidly and accurately identifies CRISPRs in large DNA strings, such as genomes and metagenomes. CRT was compared to CRISPR detection tools, Patscan and Pilercr. In terms of correctness, CRT was shown to be very reliable, demonstrating significant improvements over Patscan for measures precision, recall and quality. When compared to Pilercr, CRT showed improved performance for recall and quality. In terms of speed, CRT also demonstrated superior performance, especially for genomes containing large numbers of repeats. In this paper a new tool was introduced for the automatic detection of CRISPR elements. This tool, CRT, was shown to be a significant improvement over the current techniques for CRISPR identification. CRT's approach to detecting repetitive sequences is straightforward. It uses a simple sequential scan of a DNA sequence and detects repeats directly without any major conversion or preprocessing of the input. This leads to a program that is easy to describe and understand; yet it is very accurate, fast and memory efficient, being O(n) in space and O(nm/l) in time.

  3. Evolution of Determinant Factors of Repeated Sprint Ability

    Directory of Open Access Journals (Sweden)

    Pareja-Blanco Fernando

    2016-12-01

    Full Text Available The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs, a straight-line 30 m sprint (T30, an RSA test (6 x 20 + 20 m with 20 s recovery, a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1 and a 20 m shuttle run test (20mSRT. The mean (RSAmean, the fastest (RSAbest, each single sprint time, and the percentage in a sprint decrease (%Dec in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82 and with all single sprints (p < 0.05, showing a downward trend as the number of sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p < 0.05 relationships with body mass (r = .44, adiposity (r = .59 and the YYIRT-1 (r = -.62, increasing as the number of repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints.

  4. Evaluation of lumbar disc and spine morphology: long-term repeatability and comparison of methods.

    Science.gov (United States)

    Belavý, D L; Armbrecht, G; Felsenberg, D

    2012-08-01

    Establishing the long-term repeatability of quantitative measures of lumbar intervertebral disc and spinal morphology is important for planning interventional studies. We aimed to examine this issue and to determine to what extent a smaller number of measurements per disc or vertebral level could be used to save operator time without compromising measurement precision. Twenty-one healthy male subjects were scanned at baseline and 1.5 years later. On sagittal MR-scans intervertebral disc cross-sectional area, anterior disc height, posterior disc height, intervertebral angle and intervertebral length were measured. The repeatability of the average value from all sagittal images or from 1, 3, 5 or 7 images centred at the spinous process was evaluated. Bland-Altman analysis showed all measurements to be repeatable between testing days. Intervertebral length was the most precise measurement (coefficients of variation [CVs] between 1.2% and 1.5%), followed by disc cross-sectional area (CVs between 2.9% and 3.6%). Variance component analysis showed that using 7 images, but not 1, 3 or 5 images, resulted in a similar level of measurement error as when measurements from all images were included.

  5. Repeated-sprint and effort ability in rugby league players.

    Science.gov (United States)

    Johnston, Rich D; Gabbett, Tim J

    2011-10-01

    The aim of this study was to (a) investigate the influence of tackling on repeated-sprint performance; (b) determine whether repeated-sprint ability (RSA) and repeated-effort ability (REA) are 2 distinct qualities; and (c) assess the test-retest reliability of repeated-sprint and repeated-effort tests in rugby league. Twelve rugby league players performed a repeated-sprint (12 × 20-m sprints performed on a 20-second cycle) and a repeated-effort (12 × 20-m sprints with intermittent tackling, performed on a 20-second cycle) test 7 days apart. The test-retest reliability of these tests was also established. Heart rate and rating of perceived exertion were recorded throughout the tests. There was a significantly greater (p ≤ 0.05) and large effect size (ES) differences for total sprint time (ES = 1.19), average heart rate (ES = 1.64), peak heart rate (ES = 1.35), and perceived exertion (ES = 3.39) for the repeated-effort test compared with the repeated-sprint test. A large difference (ES = 1.02, p = 0.06) was detected for percentage decrement between the 2 tests. No significant relationship was found between the repeated-sprint and repeated-effort tests for any of the dependent variables. Both tests proved reliable, with total sprint time being the most reliable method of assessing performance. This study demonstrates that the addition of tackling significantly increases the physiological response to repeated-sprint exercise and reduces repeated-sprint performance in rugby league players. Furthermore, RSA and REA appear to be 2 distinct qualities that can be reliably assessed with total time being the most reliable measure of performance.

  6. REPdenovo: Inferring De Novo Repeat Motifs from Short Sequence Reads.

    Directory of Open Access Journals (Sweden)

    Chong Chu

    Full Text Available Repeat elements are important components of eukaryotic genomes. One limitation in our understanding of repeat elements is that most analyses rely on reference genomes that are incomplete and often contain missing data in highly repetitive regions that are difficult to assemble. To overcome this problem we develop a new method, REPdenovo, which assembles repeat sequences directly from raw shotgun sequencing data. REPdenovo can construct various types of repeats that are highly repetitive and have low sequence divergence within copies. We show that REPdenovo is substantially better than existing methods both in terms of the number and the completeness of the repeat sequences that it recovers. The key advantage of REPdenovo is that it can reconstruct long repeats from sequence reads. We apply the method to human data and discover a number of potentially new repeats sequences that have been missed by previous repeat annotations. Many of these sequences are incorporated into various parasite genomes, possibly because the filtering process for host DNA involved in the sequencing of the parasite genomes failed to exclude the host derived repeat sequences. REPdenovo is a new powerful computational tool for annotating genomes and for addressing questions regarding the evolution of repeat families. The software tool, REPdenovo, is available for download at https://github.com/Reedwarbler/REPdenovo.

  7. Source coding model for repeated snapshot imaging

    CERN Document Server

    Li, Junhui; Yang, Dongyue; wu, Guohua; Yin, Longfei; Guo, Hong

    2016-01-01

    Imaging based on successive repeated snapshot measurement is modeled as a source coding process in information theory. The necessary number of measurement to maintain a certain level of error rate is depicted as the rate-distortion function of the source coding. Quantitative formula of the error rate versus measurement number relation is derived, based on the information capacity of imaging system. Second order fluctuation correlation imaging (SFCI) experiment with pseudo-thermal light verifies this formula, which paves the way for introducing information theory into the study of ghost imaging (GI), both conventional and computational.

  8. Cluster State Quantum Computation and the Repeat-Until Scheme

    Science.gov (United States)

    Kwek, L. C.

    Cluster state computation or the one way quantum computation (1WQC) relies on an initially highly entangled state (called a cluster state) and an appropriate sequence of single qubit measurements along different directions, together with feed-forward based on the measurement results, to realize a quantum computation process. The final result of the computation is obtained by measuring the last remaining qubits in the computational basis. In this short tutorial on cluster state quantum computation, we will also describe the basic ideas of a cluster state and proceed to describe how a single qubit operation can be done on a cluster state. Recently, we proposed a repeat-until-success (RUS) scheme that could effectively be used to realize one-way quantum computer on a hybrid system of photons and atoms. We will briefly describe this RUS scheme and show how it can be used to entangled two distant stationary qubits.

  9. Thermal stability of chicken brain {alpha}-spectrin repeat 17: a spectroscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Annette K. [University of Bergen, Department of Chemistry (Norway); Kieffer, Bruno [Ecole Superieure de Biotechnologie de Strasbourg, IGBMC Biomolecular NMR Group, CNRS UMR 7104 (France); Trave, Gilles [Ecole Superieure de Biotechnologie de Strasbourg, Equipe Oncoproteines, IREBS, UMR 7242 (France); Froystein, Nils Age [University of Bergen, Department of Chemistry (Norway); Raae, Arnt J., E-mail: arnt.raae@mbi.uib.no [University of Bergen, Department of Molecular Biology (Norway)

    2012-06-15

    Spectrin is a rod-like multi-modular protein that is mainly composed of triple-helical repeats. These repeats show very similar 3D-structures but variable conformational and thermodynamical stabilities, which may be of great importance for the flexibility and dynamic behaviour of spectrin in the cell. For instance, repeat 17 (R17) of the chicken brain spectrin {alpha}-chain is four times less stable than neighbouring repeat 16 (R16) in terms of Increment G. The structure of spectrin repeats has mainly been investigated by X-ray crystallography, but the structures of a few repeats, e.g. R16, have also been determined by NMR spectroscopy. Here, we undertook a detailed characterization of the neighbouring R17 by NMR spectroscopy. We assigned most backbone resonances and observed NOE restraints, relaxation values and coupling constants that all indicated that the fold of R17 is highly similar to that of R16, in agreement with previous X-ray analysis of a tandem repeat of the two domains. However, {sup 15}N heteronuclear NMR spectra measured at different temperatures revealed particular features of the R17 domain that might contribute to its lower stability. Conformational exchange appeared to alter the linker connecting R17 to R16 as well as the BC-loop in close proximity. In addition, heat-induced splitting was observed for backbone resonances of a few spatially related residues including V99 of helix C, which in R16 is replaced by the larger hydrophobic tryptophan residue that is relatively conserved among other spectrin repeats. These data support the view that the substitution of tryptophan by valine at this position may contribute to the lower stability of R17.

  10. Repeated-sprint ability and aerobic fitness.

    Science.gov (United States)

    Thébault, Nicolas; Léger, Luc A; Passelergue, Philippe

    2011-10-01

    The purpose of this study was to reinvestigate the relationship between aerobic fitness and fatigue indices of repeated-sprint ability (RSA), with special attention to methodological normalization. Soldiers were divided into low (n = 10) and high (n = 9) fitness groups according to a preset maximal aerobic speed (MAS) of 17 km·h(-1) (∼60 ml O2·kg(-1)·min) measured with the University of Montreal Track Test (UMTT). Subjects' assessment included the RSA test (3 sets of 5 40-m sprints with 1-minute rest between sprints and 1.5 minutes between sets), a 40-m sprint (criterion test used in the computation of fatigue indices for the RSA test), strength and power measurement of the lower limbs, and the 20-m shuttle run test (20-m SRT) and the UMTT, which are measures of maximal aerobic power. The highest correlation with the RSA fatigue indices was obtained with the 20-m SRT (r = 0.90, p = 0.0001, n = 19), a test with 180° direction changes and accelerations and decelerations. The lower correlation (r = 0.66, p repeated sprints and achieved better recovery between series. A MAS of at least 17 km·h(-1) favors constant and high speed level during repeated sprints. From a practical point of view, a high aerobic fitness is a precious asset in counteracting fatigue in sports with numerous sprint repetitions.

  11. Towards Quantum Repeaters

    Science.gov (United States)

    Gisin, Nicolas

    2009-05-01

    The ultimate limit of direct point to point quantum key distribution is around 300-500 km. Longer distances fiber-based quantum communication will require both high-fidelity entanglement swapping and multi-mode quantum memories. A new protocol for an efficient multimode quantum memory based on atomic ensembles has been developed and demonstrated. The rare-earth ions ensemble is ``frozen'' in a crystal inside a cryostat. The protocol, named AFC (Atomic Frequency Comb) is inspired from photon echoes, but avoids any control light pulse after the single-photon(s) is (are) stored in the medium, thus avoiding any noise due to fluorescence. First results on the new protocol for quantum memories in Nd:YVO4 doped crystals demonstrate a quantum light-matter interface at the single-photon level. The coherence of the re-emitted photons is investigated in an interference experiment showing net visibilities above 95%. Further results in Nd:YSO (Geneva), Tm:YAG (Paris) and Pr:YSO (Lund) shall also be presented. Many hundreds of km long quantum communication is a long term objective. Many of the necessary building blocks have been demonstrated, but usually in independent experiments and with insufficient fidelities and specifications to meet the goal. Still, today's the roadmap is relatively clear and a lot of interesting physics shall be found along the journey.

  12. Reliability and criterion-related validity of a new repeated agility test

    Directory of Open Access Journals (Sweden)

    MS Fessi

    2016-04-01

    Full Text Available The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT and total time (TT of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90. The standard error of measurement (<0.50 showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS and a repeated sprint with changes of direction (RSCD. Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001. The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up.

  13. Improving HSDPA Indoor Coverage and Throughput by Repeater and Dedicated Indoor System

    Directory of Open Access Journals (Sweden)

    2009-03-01

    Full Text Available The target of the paper is to provide guidelines for indoor planning and optimization using an outdoor-to-indoor repeater or a dedicated indoor system. The paper provides practical information for enhancing the performance of high-speed downlink packet access (HSDPA in an indoor environment. The capabilities of an outdoor-to-indoor analog WCDMA repeater are set against a dedicated indoor system and, furthermore, compared to indoor coverage of a nearby macrocellular base station. An extensive measurement campaign with varying system configurations was arranged in different indoor environments. The results show that compared to dedicated indoor systems, similar HSDPA performance can be provided by extending macrocellular coverage inside buildings using an outdoor-to-indoor repeater. According to the measurements, the pilot coverage planning threshold of about −80 dBm ensures a 2500 kbps throughput for shared HSDPA connections. Improving the coverage above −80 dBm seems to provide only small advantage in HSDPA throughput. Of course, the pilot planning thresholds may change if different channel power allocations are used. In addition, network performance can be further improved by increasing the antenna density in the serving distributed antenna system. Finally, good performance of repeater implementation needs careful repeater gain setting and donor antenna siting.

  14. Improving HSDPA Indoor Coverage and Throughput by Repeater and Dedicated Indoor System

    Directory of Open Access Journals (Sweden)

    Isotalo Tero

    2008-01-01

    Full Text Available Abstract The target of the paper is to provide guidelines for indoor planning and optimization using an outdoor-to-indoor repeater or a dedicated indoor system. The paper provides practical information for enhancing the performance of high-speed downlink packet access (HSDPA in an indoor environment. The capabilities of an outdoor-to-indoor analog WCDMA repeater are set against a dedicated indoor system and, furthermore, compared to indoor coverage of a nearby macrocellular base station. An extensive measurement campaign with varying system configurations was arranged in different indoor environments. The results show that compared to dedicated indoor systems, similar HSDPA performance can be provided by extending macrocellular coverage inside buildings using an outdoor-to-indoor repeater. According to the measurements, the pilot coverage planning threshold of about −80 dBm ensures a 2500 kbps throughput for shared HSDPA connections. Improving the coverage above −80 dBm seems to provide only small advantage in HSDPA throughput. Of course, the pilot planning thresholds may change if different channel power allocations are used. In addition, network performance can be further improved by increasing the antenna density in the serving distributed antenna system. Finally, good performance of repeater implementation needs careful repeater gain setting and donor antenna siting.

  15. Impact of Inclusion or Exclusion of Repeaters on Test Equating

    Science.gov (United States)

    Puhan, Gautam

    2011-01-01

    This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…

  16. History repeats itself: genomic divergence in copepods.

    Science.gov (United States)

    Renaut, Sébastien; Dion-Côté, Anne-Marie

    2016-04-01

    Press stop, erase everything from now till some arbitrary time in the past and start recording life as it evolves once again. Would you see the same tape of life playing itself over and over, or would a different story unfold every time? The late Steven Jay Gould called this experiment replaying the tape of life and argued that any replay of the tape would lead evolution down a pathway radically different from the road actually taken (Gould 1989). This thought experiment has puzzled evolutionary biologists for a long time: how repeatable are evolutionary events? And if history does indeed repeat itself, what are the factors that may help us predict the path taken? A powerful means to address these questions at a small evolutionary scale is to study closely related populations that have evolved independently, under similar environmental conditions. This is precisely what Pereira et al. (2016) set out to do using marine copepods Tigriopus californicus, and present their results in this issue of Molecular Ecology. They show that evolution can be repeatable and even partly predictable, at least at the molecular level. As expected from theory, patterns of divergence were shaped by natural selection. At the same time, strong genetic drift due to small population sizes also constrained evolution down a similar evolutionary road, and probably contributed to repeatable patterns of genomic divergence.

  17. Avaliação do desempenho zootécnico de genótipos de frangos de corte utilizando-se a análise de medidas repetidas Performance evaluation of broiler genotypes by repeated measures

    Directory of Open Access Journals (Sweden)

    Millor Fernandes do Rosário

    2005-12-01

    Full Text Available Objetivou-se avaliar genótipos de frangos de corte por meio do desempenho zootécnico utilizando-se medidas repetidas. Os tratamentos consistiram de quatro genótipos (A, B, C e D e dois sexos avaliados em seis idades (7, 14, 21, 28, 35 e 42 dias. As variáveis analisadas foram: consumo médio de alimento (CONS, peso vivo médio (PV e conversão alimentar (CA. O delineamento experimental foi em blocos incompletos desbalanceados, em esquema fatorial 4x2 nas parcelas experimentais, com seis medidas realizadas no decorrer do experimento. A análise estatística foi realizada por meio do procedimento MIXED do SAS®, sendo testadas cinco estruturas de variância e covariância do erro. As médias foram estimadas por quadrados mínimos e comparadas pelo teste Tukey-Kramer. Foram estimadas funções de resposta quadrática para CONS e CA e Gompertz para PV e seus respectivos coeficientes de determinação, pelo procedimento NLIN do SAS®. Detectaram-se efeitos de algumas interações triplas ou duplas para todas as variáveis. Verificaram-se diferenças significativas entre genótipos dentro de cada idade e sexo para CONS e PV e para CA entre genótipos e sexos, dentro de cada idade, apenas aos 42 e a partir dos 21 dias, respectivamente. Constatou-se que o genótipo D, apesar de apresentar maiores médias de CONS e PV, não mostrou menor CA, que foi verificada nos genótipos C e B. As funções de resposta estimadas explicaram adequadamente cada variável em função da idade, constatando-se que o CONS e PV dos machos do genótipo D foram maiores a partir dos 14 dias e dos 28 aos 42 dias, distinguindo este tratamento dos demais. A melhor CA foi verificada nos machos e no genótipo C. É possível avaliar o desempenho zootécnico de frangos de corte por medidas repetidas, sendo que os genótipos B e C apresentaram melhor desempenho zootécnico.The objetive of this study was to evaluate the performance of broiler genotypes using repeated measurements

  18. Casimir experiments showing saturation effects

    CERN Document Server

    Sernelius, Bo E

    2009-01-01

    We address several different Casimir experiments where theory and experiment disagree. First out is the classical Casimir force measurement between two metal half spaces; here both in the form of the torsion pendulum experiment by Lamoreaux and in the form of the Casimir pressure measurement between a gold sphere and a gold plate as performed by Decca et al.; theory predicts a large negative thermal correction, absent in the high precision experiments. The third experiment is the measurement of the Casimir force between a metal plate and a laser irradiated semiconductor membrane as performed by Chen et al.; the change in force with laser intensity is larger than predicted by theory. The fourth experiment is the measurement of the Casimir force between an atom and a wall in the form of the measurement by Obrecht et al. of the change in oscillation frequency of a 87 Rb Bose-Einstein condensate trapped to a fused silica wall; the change is smaller than predicted by theory. We show that saturation effects can exp...

  19. Children’s School-Breakfast Reports and School-Lunch Reports (in 24-hour Dietary Recalls): Conventional and Reporting-Error-Sensitive Measures Show Inconsistent Accuracy Results for Retention Interval and for Breakfast Location

    Science.gov (United States)

    Baxter, Suzanne Domel; Guinn, Caroline H.; Smith, Albert F.; Hitchcock, David B.; Royer, Julie A.; Puryear, Megan P.; Collins, Kathleen L.; Smith, Alyssa L.

    2017-01-01

    Validation-study data were analyzed to investigate retention interval (RI) and prompt effects on accuracy of fourth-grade children’s reports of school-breakfast and school-lunch (in 24-hour recalls), and accuracy of school-breakfast reports by breakfast location (classroom; cafeteria). Randomly-selected fourth-grade children at 10 schools in four districts were observed eating school-provided breakfast and lunch, and interviewed under one of eight conditions (two RIs [short (prior-24-hour recall obtained in afternoon); long (previous-day recall obtained in morning)] crossed with four prompts [forward (distant-to-recent), meal-name (breakfast, etc.), open (no instructions), reverse (recent-to-distant)]). Each condition had 60 children (half girls). Of 480 children, 355 and 409 reported meals satisfying criteria for reports of school-breakfast and school-lunch, respectively. For breakfast and lunch separately, a conventional measure—report rate—and reporting-error-sensitive measures—correspondence rate and inflation ratio—were calculated for energy per meal-reporting child. Correspondence rate and inflation ratio—but not report rate—showed better accuracy for school-breakfast and school-lunch reports with the short than long RI; this pattern was not found for some prompts for each sex. Correspondence rate and inflation ratio showed better school-breakfast report accuracy for the classroom than cafeteria location for each prompt, but report rate showed the opposite. For each RI, correspondence rate and inflation ratio showed better accuracy for lunch than breakfast, but report rate showed the opposite. When choosing RI and prompts for recalls, researchers and practitioners should select short RIs to maximize accuracy. Recommendations for prompt selections are less clear. As report rates distort validation-study accuracy conclusions, reporting-error-sensitive measures are recommended. PMID:26865356

  20. Repeatability and validity of the combined arm-leg (Cruiser) ergometer.

    Science.gov (United States)

    Simmelink, Elisabeth K; Wempe, Johan B; Geertzen, Jan H B; Dekker, Rienk

    2009-12-01

    The measurement of physical fitness of lower limb amputees is difficult, as the commonly used ergometer tests have limitations. A combined arm-leg (Cruiser) ergometer might be valuable. The aim of this study was to establish the repeatability and validity of the combined arm-leg (Cruiser) ergometer. Thirty healthy volunteers carried out three incremental exercise tests, once on the bicycle ergometer and twice on the Cruiser ergometer. The repeatability of the Cruiser ergometer was assessed by studying the mean values of the test-retest and the validity by studying the mean values of the bicycle and the two Cruiser ergometer tests. The intraclass correlation coefficient for repeated measurements on the Cruiser ergometer was 0.84 for the maximal oxygen consumption (VO2max), and 0.71 for the maximal heart rate (HRmax). The intraclass correlation coefficient for the measurements on the bicycle ergometer and the Cruiser ergometer was 0.86 for the VO2max and 0.73 for HRmax. Bland and Altman plots for VO2max and HRmax showed a bias close to zero and a great accuracy. The conclusion of this study is that the Cruiser ergometer provides a repeatable and valid measurement of physical fitness in healthy volunteers. Its value in clinical practice for lower limb amputees needs to be further established.

  1. Mononucleotide repeats are asymmetrically distributed in fungal genes

    Directory of Open Access Journals (Sweden)

    de Graaff Leo H

    2008-12-01

    Full Text Available Abstract Background Systematic analyses of sequence features have resulted in a better characterisation of the organisation of the genome. A previous study in prokaryotes on the distribution of sequence repeats, which are notoriously variable and can disrupt the reading frame in genes, showed that these motifs are skewed towards gene termini, specifically the 5' end of genes. For eukaryotes no such intragenic analysis has been performed, though this could indicate the pervasiveness of this distribution bias, thereby helping to expose the selective pressures causing it. Results In fungal gene repertoires we find a similar 5' bias of intragenic mononucleotide repeats, most notably for Candida spp., whereas e.g. Coccidioides spp. display no such bias. With increasing repeat length, ever larger discrepancies are observed in genome repertoire fractions containing such repeats, with up to an 80-fold difference in gene fractions at repeat lengths of 10 bp and longer. This species-specific difference in gene fractions containing large repeats could be attributed to variations in intragenic repeat tolerance. Furthermore, long transcripts experience an even more prominent bias towards the gene termini, with possibly a more adaptive role for repeat-containing short transcripts. Conclusion Mononucleotide repeats are intragenically biased in numerous fungal genomes, similar to earlier studies on prokaryotes, indicative of a similar selective pressure in gene organization.

  2. Limitations on quantum key repeaters.

    Science.gov (United States)

    Bäuml, Stefan; Christandl, Matthias; Horodecki, Karol; Winter, Andreas

    2015-04-23

    A major application of quantum communication is the distribution of entangled particles for use in quantum key distribution. Owing to noise in the communication line, quantum key distribution is, in practice, limited to a distance of a few hundred kilometres, and can only be extended to longer distances by use of a quantum repeater, a device that performs entanglement distillation and quantum teleportation. The existence of noisy entangled states that are undistillable but nevertheless useful for quantum key distribution raises the question of the feasibility of a quantum key repeater, which would work beyond the limits of entanglement distillation, hence possibly tolerating higher noise levels than existing protocols. Here we exhibit fundamental limits on such a device in the form of bounds on the rate at which it may extract secure key. As a consequence, we give examples of states suitable for quantum key distribution but unsuitable for the most general quantum key repeater protocol.

  3. Secret key rates for an encoded quantum repeater

    Science.gov (United States)

    Bratzik, Sylvia; Kampermann, Hermann; Bruß, Dagmar

    2014-03-01

    We investigate secret key rates for the quantum repeater using encoding [L. Jiang et al., Phys. Rev. A 79, 032325 (2009), 10.1103/PhysRevA.79.032325] and compare them to the standard repeater scheme by Briegel, Dür, Cirac, and Zoller. The former scheme has the advantage of a minimal consumption of classical communication. We analyze the trade-off in the secret key rate between the communication time and the required resources. For this purpose we introduce an error model for the repeater using encoding which allows for input Bell states with a fidelity smaller than one, in contrast to the model given by L. Jiang et al. [Phys. Rev. A 79, 032325 (2009), 10.1103/PhysRevA.79.032325]. We show that one can correct additional errors in the encoded connection procedure of this repeater and develop a suitable decoding algorithm. Furthermore, we derive the rate of producing entangled pairs for the quantum repeater using encoding and give the minimal parameter values (gate quality and initial fidelity) for establishing a nonzero secret key. We find that the generic quantum repeater is optimal regarding the secret key rate per memory per second and show that the encoded quantum repeater using the simple three-qubit repetition code can even have an advantage with respect to the resources compared to other recent quantum repeater schemes with encoding.

  4. Novel multiplex format of an extended multilocus variable-number-tandem-repeat analysis of Clostridium difficile correlates with tandem repeat sequence typing.

    Science.gov (United States)

    Jensen, Mie Birgitte Frid; Engberg, Jørgen; Larsson, Jonas T; Olsen, Katharina E P; Torpdahl, Mia

    2015-03-01

    Subtyping of Clostridium difficile is crucial for outbreak investigations. An extended multilocus variable-number tandem-repeat analysis (eMLVA) of 14 variable number tandem repeat (VNTR) loci was validated in multiplex format compatible with a routine typing laboratory and showed excellent concordance with tandem repeat sequence typing (TRST) and high discriminatory power.

  5. Within-session effect of repeated stress exposure on extinction circuitry function in social anxiety disorder.

    Science.gov (United States)

    Åhs, Fredrik; Gingnell, Malin; Furmark, Tomas; Fredrikson, Mats

    2017-03-30

    Anxiety reduction following repeated exposure to stressful experiences is generally held to depend on neural processes involved in extinction of conditioned fear. We predicted that repeated exposure to stressful experiences would change activity throughout the circuitry serving extinction, including ventromedial prefrontal cortex (vmPFC), the hippocampus and the amygdala. To test this prediction, 36 participants diagnosed with SAD performed two successive speeches in front of an observing audience while regional cerebral blood flow (rCBF) was recorded using positron emission tomography. To control for non-anxiolytic effects of repeated exposure, rCBF was also measured during repeated presentations of neutral and angry facial expressions. Results showed that anxiety ratings and heart rate decreased from the first to the second speech, indicating an anxiolytic effect of repeated exposure. Exposure attenuated rCBF in the amygdala whereas no change in rCBF was observed in the vmPFC or hippocampus. The rCBF-reductions in the amygdala were greater following repetition of the speech task than repetition of face exposure indicating that they were specific to anxiety attenuation and not due to a reduced novelty. Our findings suggest that amygdala-related attenuation processes are key to understanding the working mechanisms of exposure therapy.

  6. The effect of seed electrons on the repeatability of atmospheric pressure plasma plume propagation: I. Experiment

    Science.gov (United States)

    Nie, L.; Chang, L.; Xian, Y.; Lu, X.

    2016-09-01

    One of the significant differences between the traditional streamers and the plasma jets is the repeatability of their propagation. In this paper, the effect of the seed electron density on the repeatability of the plasma jets is investigated. The seed electron density plays an essential role in the propagation of plasma plume which is in either repeatable mode or random mode depending on the frequency of the applied voltage and the mixture percentage of the working gas. By measuring the propagation velocities and the ignition delay time, it is found that the propagation velocities of the plasma plume are independent of the seed electron density. However, the jitter of the ignition delay time strongly depends on the frequency of the applied voltage and the mixture percentage of the working gas. After detailed analyzing of the experiment results, it is concluded that the minimum seed electron density required for the plasma bullet to propagate in repeatable mode is on the order of 108 cm-3 for gas pressure of 2 × 104 Pa. The minimum required seed electron density for the gas pressure of 4 × 103 Pa is on the order of 107 cm-3. Further analysis shows that, at one atmospheric pressure, the required minimum seed electron density for repeatable mode is on the order of 109 cm-3.

  7. EAMJ Dec. Repeatability.indd

    African Journals Online (AJOL)

    2008-12-12

    Dec 12, 2008 ... Results:Kappa values for four-week repeatability for the wheeze and asthma questions were 0.61 ... for logistic, cultural and ethical reasons, to use ... individual with baseline forced expiratory volume in .... period is likely to also include the effects of true ... data, the writing of the manuscript or the decision.

  8. Utility and necessity of repeat testing of critical values in the clinical chemistry laboratory.

    Directory of Open Access Journals (Sweden)

    Aijun Niu

    Full Text Available CONTEXT: Routine repeat testing of critical values is a long-standing practice in many clinical laboratories; however, its usefulness and necessity remain to be empirically established and no regulatory requirements yet exist for verification of the critical value results obtained by repeat analysis. OBJECTIVE: To determine whether repeat testing of critical values is useful and necessary in a clinical chemistry laboratory. METHODS: A total of 601 chemistry critical values (potassium, n = 255; sodium, n = 132; calcium, n = 108; glucose, n = 106 obtained from 72,259 routine clinical chemistry specimens were repeat tested. The absolute value and the percentage of difference between the two testing runs were calculated for each of the four critical values and then compared with the allowable error limit put forth in the College of American Pathologists (CAP. RESULTS: Among the repeat data for the 601 critical values, a total of 24 showed large differences between the initial result and the repeated result which exceeded the CAP limits for allowable error. The number and rates (% of large differences for within and outside the analytical measurement range (AMR were 12 (2.1% and 12 (41.4%, respectively. For the 572 critical values within the AMR for each test category, the mean absolute difference (mmol/L and difference(% between the two testing runs were: potassium, 0.1 mmol/L (2.7%; sodium, 2.1 mmol/L (1.7%; calcium, 0.05 mmol/L (3.0%; glucose, 0.18 mmol/L (2.6%. CONCLUSIONS: When the initial chemistry critical values are within the AMR, repeated testing does not improve accuracy and is therefore unnecessary. When the initial chemistry critical values are outside the AMR, however, the benefit of repeated testing justifies its performance and makes it necessary. Performing repeat clinical testing on a case-by-case, rather than routine, basis can improve patient care by delivering critical values more rapidly while providing savings

  9. Role of syndrome information on a one-way quantum repeater using teleportation-based error correction

    Science.gov (United States)

    Namiki, Ryo; Jiang, Liang; Kim, Jungsang; Lütkenhaus, Norbert

    2016-11-01

    We investigate a quantum repeater scheme for quantum key distribution based on the work by S. Muralidharan et al. [Phys. Rev. Lett. 112, 250501 (2014)], 10.1103/PhysRevLett.112.250501. Our scheme extends that work by making use of error syndrome measurement outcomes available at the repeater stations. We show how to calculate the secret key rates for the case of optimizing the syndrome information, while the known key rate is based on a scenario of coarse graining the syndrome information. We show that these key rates can surpass the Pirandola-Laurenza-Ottaviani-Banchi bound on secret key rates of direct transmission over lossy bosonic channels.

  10. 数控机床加工在机检测测量头的精准重复定位机构设计%Design of Precisely Repeat Positioning Mechanism for On-machine Measurement Measuring-head of CNC Machine Tool Manufacturing

    Institute of Scientific and Technical Information of China (English)

    陆东明

    2016-01-01

    通过对测量头测量感应技术和无线数据传输技术以及数控机床控制系统信号传输原理的研究,为达到测量头重复定位精度为1μm,设计了磁体组件,利用磁感应力使测量杆精准复位。用此测量头在数控机床上测量直径30 mm标准钢球,经过连续5万次测试,由计算机宏程序软件运算得出的钢球直径数值差异在1μm,符合精密测量工具精度要求。%Based on the research of measuring head sensing technology, wireless data transmission technology and CNC machine tool control signal transmission principle, a set of magnetic subassembly, which utilized the force caused by magnetic induction to reset measuring rod precisely, was designed to achieve repeat positioning accuracy within 1 μm for measuring head.Such measuring head equipped with magnetic subassembly was tested to measure diameter 30 mm standard steel balls on CNC machine tool.After 50 000 times continuously test, the steel ball diameter difference calculated and analyzed by macro program of computer software was controlled less than 1μm.The Testing results prove that the accuracy meets requirements.

  11. A note on renegotiation in repeated Bertrand duopolies

    DEFF Research Database (Denmark)

    Andersson, Ola; Wengström, Erik Roland

    2007-01-01

    Weak Renegotiation-Proofness (WRP) singles out marginal cost pricing as a unique pure-strategy equilibrium of the infinitely repeated Bertrand duopoly. We show that, with a discrete strategy space, WRP does not eliminate any relevant subgame perfect equilibrium outcome......Weak Renegotiation-Proofness (WRP) singles out marginal cost pricing as a unique pure-strategy equilibrium of the infinitely repeated Bertrand duopoly. We show that, with a discrete strategy space, WRP does not eliminate any relevant subgame perfect equilibrium outcome...

  12. Repeatability of Response to Asthma Medications

    Science.gov (United States)

    Wu, Ann; Tantisira, Kelan; Li, Lingling; Schuemann, Brooke; Weiss, Scott

    2010-01-01

    Background Pharmacogenetic studies of drug response in asthma assume that patients respond consistently to a treatment but that treatment response varies across patients, however, no formal studies have demonstrated this. Objective To determine the repeatability of commonly used outcomes for treatment response to asthma medications: bronchodilator response, forced expiratory volume in 1 second (FEV1), and provocative concentration of methacholine producing a 20% decline in FEV1 (PC20). Methods The Childhood Asthma Management Program (CAMP) was a multi-center clinical trial of children randomized to receiving budesonide, nedocromil, or placebo. We determined the intraclass correlation coefficient (ICC) for each outcome over repeated visits over four years in CAMP using mixed effects regression models. We adjusted for the covariates: age, race/ethnicity, height, family income, parental education, and symptom score. We incorporated each outcome for each child as repeated outcome measurements and stratified by treatment group. Results The ICC for bronchodilator response was 0.31 in the budesonide group, 0.35 in the nedocromil group, and 0.40 in the placebo group, after adjusting for covariates. The ICC for FEV1 was 0.71 in the budesonide group, 0.60 in the nedocromil group, and 0.69 in the placebo group, after adjusting for covariates. The ICC for PC20 was 0.67 in the budesonide and placebo groups and 0.73 in the nedocromil group, after adjusting for covariates. Conclusion The within treatment group repeatability of FEV1 and PC20 are high; thus these phenotypes are heritable. FEV1 and PC20 may be better phenotypes than bronchodilator response for studies of treatment response in asthma. PMID:19064281

  13. Exposure to polycyclic aromatic hydrocarbons among never smokers in Golestan Province, Iran, an area of high incidence of esophageal cancer – a cross-sectional study with repeated measurement of urinary 1-OHPG in two seasons

    Directory of Open Access Journals (Sweden)

    Farhad eIslami

    2012-02-01

    Full Text Available Studies have suggested a possible role of polycyclic aromatic hydrocarbons (PAHs in the etiology of esophageal cancer in Golestan Province, Iran, where incidence of this cancer is very high. In order to investigate the patterns of non-smoking related exposure to PAHs in Golestan, we conducted a cross-sectional study collecting questionnaire data, genotyping polymorphisms related to PAH metabolism, and measuring levels of 1-hydroxypyrene glucuronide (1-OHPG, a PAH metabolite, in urine samples collected in two seasons from the same group of 111 randomly-selected never-smoking women. Beta-coefficients for correlations between 1-OHPG as dependent variable and other variables were calculated using linear regression models. The creatinine-adjusted 1-OHPG levels in both winter and summer samples were approximately 110 μmol/molCr (P for seasonal difference= 0.40. In winter, red meat intake (β= 0.208; P= 0.03, processed meat intake (β= 0.218; P= 0.02 and GSTT1-02 polymorphism (null genotype: β= 0.228; P= 0.02 showed significant associations with 1-OHPG levels, while CYP1B1-07 polymorphism (GG versus AA+GA genotypes: β= –0.256; P= 0.008 showed an inverse association. In summer, making bread at home (>weekly versus never: β= 0.203; P= 0.04, second-hand smoke (exposure to ≥3 cigarettes versus no exposure: β= 0.254; P= 0.01, and GSTM1-02 null genotype (β= 0.198; P= 0.04 showed significant associations with 1-OHPG levels, but GSTP1-02 polymorphism (CT+TT versus CC: β= –0.218; P= 0.03 showed an inverse association. This study confirms high exposure of the general population in Golestan to PAHs and suggests that certain foods, cooking methods, and genetic polymorphisms increase exposure to PAHs.

  14. Frequency Bandwidth of Half-Wave Impedance Repeater

    Directory of Open Access Journals (Sweden)

    Marek Dvorsky

    2012-01-01

    Full Text Available This article brings in the second part general information about half-wave impedance repeater. The third part describes the basic functional principles of the half-wave impedance repeater using Smith chart. The main attention is focused in part four on the derivation of repeater frequency bandwidth depending on characteristics and load impedance of unknown feeder line. Derived dependences are based on the elementary features of the feeder lines with specific length. The described functionality is proved in part 4.3 by measurement of transformed impedance using vector several unbalanced feeder lines and network analyzer VNWA3+.

  15. Step-height measurements on sand surfaces: A comparison between optical scanner and coordinate measuring machine

    DEFF Research Database (Denmark)

    Mohaghegh, Kamran; Yazdanbakhsh, Seyed Alireza; Tiedje, Niels Skat

    2016-01-01

    the same routine to touch the different positions on the polygonised mesh. Each measurement was repeated 5 times. The results of step height measurements on sand surfaces showed a maximum error of ± 12 µm for CMM, while scanner shows only ± 4 µm. Generally speaking, optical step height values were measured...

  16. Repeated Nrf2 stimulation using sulforaphane protects fibroblasts from ionizing radiation.

    Science.gov (United States)

    Mathew, Sherin T; Bergström, Petra; Hammarsten, Ola

    2014-05-01

    Most of the cytotoxicity induced by ionizing radiation is mediated by radical-induced DNA double-strand breaks. Cellular protection from free radicals can be stimulated several fold by sulforaphane-mediated activation of the transcription factor Nrf2 that regulates more than 50 genes involved in the detoxification of reactive substances and radicals. Here, we report that repeated sulforaphane treatment increases radioresistance in primary human skin fibroblasts. Cells were either treated with sulforaphane for four hours once or with four-hour treatments repeatedly for three consecutive days prior to radiation exposure. Fibroblasts exposed to repeated-sulforaphane treatment showed a more pronounced dose-dependent induction of Nrf2-regulated mRNA and reduced amount of radiation-induced free radicals compared with cells treated once with sulforaphane. In addition, radiation- induced DNA double-strand breaks measured by gamma-H2AX foci were attenuated following repeated sulforaphane treatment. As a result, cellular protection from ionizing radiation measured by the 5-ethynyl-2'-deoxyuridine (EdU) assay was increased, specifically in cells exposed to repeated sulforaphane treatment. Sulforaphane treatment was unable to protect Nrf2 knockout mouse embryonic fibroblasts, indicating that the sulforaphane-induced radioprotection was Nrf2-dependent. Moreover, radioprotection by repeated sulforaphane treatment was dose-dependent with an optimal effect at 10 uM, whereas both lower and higher concentrations resulted in lower levels of radioprotection. Our data indicate that the Nrf2 system can be trained to provide further protection from radical damage. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. StaRProtein, A Web Server for Prediction of the Stability of Repeat Proteins

    Science.gov (United States)

    Xu, Yongtao; Zhou, Xu; Huang, Meilan

    2015-01-01

    Repeat proteins have become increasingly important due to their capability to bind to almost any proteins and the potential as alternative therapy to monoclonal antibodies. In the past decade repeat proteins have been designed to mediate specific protein-protein interactions. The tetratricopeptide and ankyrin repeat proteins are two classes of helical repeat proteins that form different binding pockets to accommodate various partners. It is important to understand the factors that define folding and stability of repeat proteins in order to prioritize the most stable designed repeat proteins to further explore their potential binding affinities. Here we developed distance-dependant statistical potentials using two classes of alpha-helical repeat proteins, tetratricopeptide and ankyrin repeat proteins respectively, and evaluated their efficiency in predicting the stability of repeat proteins. We demonstrated that the repeat-specific statistical potentials based on these two classes of repeat proteins showed paramount accuracy compared with non-specific statistical potentials in: 1) discriminate correct vs. incorrect models 2) rank the stability of designed repeat proteins. In particular, the statistical scores correlate closely with the equilibrium unfolding free energies of repeat proteins and therefore would serve as a novel tool in quickly prioritizing the designed repeat proteins with high stability. StaRProtein web server was developed for predicting the stability of repeat proteins. PMID:25807112

  18. Directionality switchable gain stabilized linear repeater

    Science.gov (United States)

    Ota, Takayuki; Ohmachi, Tadashi; Aida, Kazuo

    2004-10-01

    We propose a new approach to realize a bidirectional linear repeater suitable for future optical internet networks and fault location in repeater chain with OTDR. The proposed approach is the linear repeater of simple configuration whose directionality is rearranged dynamically by electrical control signal. The repeater is composed of a magneto-optical switch, a circulator, a dynamically gain stabilized unidirectional EDFA, and control circuits. The repeater directionality is rearranged as fast as 0.1ms by an electrical control pulse. It is experimentally confirmed that OTDR with the directionality switchable repeater is feasible for repeater chain. The detailed design and performance of the repeater are also discussed, including the multi-pass interference (MPI) which may arise in the proposed repeater, the effect of the MPI on SNR degradation of the repeater chain and the feed-forward EDFA gain control circuit.

  19. CRISPR Recognition Tool (CRT: a tool for automatic detection of clustered regularly interspaced palindromic repeats

    Directory of Open Access Journals (Sweden)

    Brown Kyndall

    2007-06-01

    Full Text Available Abstract Background Clustered Regularly Interspaced Palindromic Repeats (CRISPRs are a novel type of direct repeat found in a wide range of bacteria and archaea. CRISPRs are beginning to attract attention because of their proposed mechanism; that is, defending their hosts against invading extrachromosomal elements such as viruses. Existing repeat detection tools do a poor job of identifying CRISPRs due to the presence of unique spacer sequences separating the repeats. In this study, a new tool, CRT, is introduced that rapidly and accurately identifies CRISPRs in large DNA strings, such as genomes and metagenomes. Results CRT was compared to CRISPR detection tools, Patscan and Pilercr. In terms of correctness, CRT was shown to be very reliable, demonstrating significant improvements over Patscan for measures precision, recall and quality. When compared to Pilercr, CRT showed improved performance for recall and quality. In terms of speed, CRT proved to be a huge improvement over Patscan. Both CRT and Pilercr were comparable in speed, however CRT was faster for genomes containing large numbers of repeats. Conclusion In this paper a new tool was introduced for the automatic detection of CRISPR elements. This tool, CRT, showed some important improvements over current techniques for CRISPR identification. CRT's approach to detecting repetitive sequences is straightforward. It uses a simple sequential scan of a DNA sequence and detects repeats directly without any major conversion or preprocessing of the input. This leads to a program that is easy to describe and understand; yet it is very accurate, fast and memory efficient, being O(n in space and O(nm/l in time.

  20. Repeated dose pharmacokinetics of pancopride in human volunteers.

    Science.gov (United States)

    Salva, P; Costa, J; Pérez-Campos, A; Martínez-Tobed, A

    1994-11-01

    The aim of this study was to assess the pharmacokinetic profile of pancopride after repeated oral dose administration of 20 mg pancopride in tablet form once a day for 5 d in 12 healthy male volunteers. Plasma levels were measured by HPLC using a solid phase extraction method and automated injection. The minimum quantification limit of pancopride in plasma was 2 ng mL-1. The maximum plasma concentration (mean +/- SD) after the first dose was 92.5 +/- 41.5 ng ML-1 and tmax was 1.7 +/- 0.9 h. The elimination half-life (t1/2) was 14.3 +/- 6.9 h. The area under the concentration-time curve from zero to infinity (AUC) was 997 +/- 396 ng h mL-1. The maximum plasma concentration (mean +/- SD) at steady state (day 5) was 101.8 +/- 36.9 ng mL-1 and tmax was 2.2 +/- 1.2 h. The elimination half-life (t1/2) was 16.3 +/- 2.7 h and the minimum plasma concentration (Cssmin) was 16.6 +/- 6.9 ng mL-1. The area under the concentration-time curve during the dosing interval (AUCss tau) was 995 +/- 389 ng h mL-1. The average plasma concentration at steady state (Cssav) was 43.3 +/- 16.1 ng mL-1 and the experimental accumulation ratio (RAUC) was 1.34 +/- 0.19, whereas the mean theoretical value (R) was 1.40 +/- 0.29. The results obtained showed a good correlation between the experimental plasma levels and the expected values calculated using a repeated dose two-compartment model assessed by means of the Akaike value. It is concluded that the pharmacokinetics of pancopride are not modified after repeated dose administration.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Secure quantum network coding for controlled repeater networks

    Science.gov (United States)

    Shang, Tao; Li, Jiao; Liu, Jian-wei

    2016-07-01

    To realize efficient quantum communication based on quantum repeater, we propose a secure quantum network coding scheme for controlled repeater networks, which adds a controller as a trusted party and is able to control the process of EPR-pair distribution. As the key operations of quantum repeater, local operations and quantum communication are designed to adopt quantum one-time pad to enhance the function of identity authentication instead of local operations and classical communication. Scheme analysis shows that the proposed scheme can defend against active attacks for quantum communication and realize long-distance quantum communication with minimal resource consumption.

  2. Repeatability and Reproducibility of Virtual Subjective Refraction.

    Science.gov (United States)

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-10-01

    To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.

  3. Intraspecific variation in flight metabolic rate in the bumblebee Bombus impatiens: repeatability and functional determinants in workers and drones.

    Science.gov (United States)

    Darveau, Charles-A; Billardon, Fannie; Bélanger, Kasandra

    2014-02-15

    The evolution of flight energetics requires that phenotypes be variable, repeatable and heritable. We studied intraspecific variation in flight energetics in order to assess the repeatability of flight metabolic rate and wingbeat frequency, as well as the functional basis of phenotypic variation in workers and drones of the bumblebee species Bombus impatiens. We showed that flight metabolic rate and wingbeat frequency were highly repeatable in workers, even when controlling for body mass variation using residual analysis. We did not detect significant repeatability in drones, but a smaller range of variation might have prevented us from finding significant values in our sample. Based on our results and previous findings, we associated the high repeatability of flight phenotypes in workers to the functional links between body mass, thorax mass, wing size, wingbeat frequency and metabolic rate. Moreover, differences between workers and drones were as predicted from these functional associations, where drones had larger wings for their size, lower wingbeat frequency and lower flight metabolic rate. We also investigated thoracic muscle metabolic phenotypes by measuring the activity of carbohydrate metabolism enzymes, and we found positive correlations between mass-independent metabolic rate and the activity of all enzymes measured, but in workers only. When comparing workers and drones that differ in flight metabolic rate, only the activity of the enzymes hexokinase and trehalase showed the predicted differences. Overall, our study indicates that there should be correlated evolution among physiological phenotypes at multiple levels of organization and morphological traits associated with flight.

  4. On the role of memory errors in quantum repeaters

    CERN Document Server

    Hartmann, L; Dür, W; Kraus, B

    2006-01-01

    We investigate the influence of memory errors in the quantum repeater scheme for long-range quantum communication. We show that the communication distance is limited in standard operation mode due to memory errors resulting from unavoidable waiting times for classical signals. We show how to overcome these limitations by (i) improving local memory, and (ii) introducing two new operational modes of the quantum repeater. In both operational modes, the repeater is run blindly, i.e. without waiting for classical signals to arrive. In the first scheme, entanglement purification protocols based on one-way classical communication are used allowing to communicate over arbitrary distances. However, the error thresholds for noise in local control operations are very stringent. The second scheme makes use of entanglement purification protocols with two-way classical communication and inherits the favorable error thresholds of the repeater run in standard mode. One can increase the possible communication distance by an o...

  5. Airborne Radar Interferometric Repeat-Pass Processing

    Science.gov (United States)

    Hensley, Scott; Michel, Thierry R.; Jones, Cathleen E.; Muellerschoen, Ronald J.; Chapman, Bruce D.; Fore, Alexander; Simard, Marc; Zebker, Howard A.

    2011-01-01

    Earth science research often requires crustal deformation measurements at a variety of time scales, from seconds to decades. Although satellites have been used for repeat-track interferometric (RTI) synthetic-aperture-radar (SAR) mapping for close to 20 years, RTI is much more difficult to implement from an airborne platform owing to the irregular trajectory of the aircraft compared with microwave imaging radar wavelengths. Two basic requirements for robust airborne repeat-pass radar interferometry include the ability to fly the platform to a desired trajectory within a narrow tube and the ability to have the radar beam pointed in a desired direction to a fraction of a beam width. Uninhabited Aerial Vehicle Synthetic Aperture Radar (UAVSAR) is equipped with a precision auto pilot developed by NASA Dryden that allows the platform, a Gulfstream III, to nominally fly within a 5 m diameter tube and with an electronically scanned antenna to position the radar beam to a fraction of a beam width based on INU (inertial navigation unit) attitude angle measurements.

  6. ACCA phosphopeptide recognition by the BRCT repeats of BRCA1.

    Science.gov (United States)

    Ray, Hind; Moreau, Karen; Dizin, Eva; Callebaut, Isabelle; Venezia, Nicole Dalla

    2006-06-16

    The tumour suppressor gene BRCA1 encodes a 220 kDa protein that participates in multiple cellular processes. The BRCA1 protein contains a tandem of two BRCT repeats at its carboxy-terminal region. The majority of disease-associated BRCA1 mutations affect this region and provide to the BRCT repeats a central role in the BRCA1 tumour suppressor function. The BRCT repeats have been shown to mediate phospho-dependant protein-protein interactions. They recognize phosphorylated peptides using a recognition groove that spans both BRCT repeats. We previously identified an interaction between the tandem of BRCA1 BRCT repeats and ACCA, which was disrupted by germ line BRCA1 mutations that affect the BRCT repeats. We recently showed that BRCA1 modulates ACCA activity through its phospho-dependent binding to ACCA. To delineate the region of ACCA that is crucial for the regulation of its activity by BRCA1, we searched for potential phosphorylation sites in the ACCA sequence that might be recognized by the BRCA1 BRCT repeats. Using sequence analysis and structure modelling, we proposed the Ser1263 residue as the most favourable candidate among six residues, for recognition by the BRCA1 BRCT repeats. Using experimental approaches, such as GST pull-down assay with Bosc cells, we clearly showed that phosphorylation of only Ser1263 was essential for the interaction of ACCA with the BRCT repeats. We finally demonstrated by immunoprecipitation of ACCA in cells, that the whole BRCA1 protein interacts with ACCA when phosphorylated on Ser1263.

  7. PHYSIOLOGICAL RESPONSES AND MOOD STATES AFTER DAILY REPEATED PROLONGED EXERCISE

    Directory of Open Access Journals (Sweden)

    Ilkka Väänänen

    2004-10-01

    Full Text Available The purpose of this study was to describe the physiological responses to daily repeated acute but non-competitive prolonged exercise during a 4-day march and a 2-day cross-country ski event to the cardiorespiratory, autonomic nervous, musculoskeletal and endocrine systems. Mood states were also evaluated after these repeated exercises. The data of these short-term follow-up (reversal field trials was collected from healthy, 23 to 48 year old Finnish male soldiers in 1993 (n=6 and 1994 (n=15 during the "International Four-Day Long-Distance March" in Nijmegen, The Netherlands, and from ten healthy, 22 to 48 year old Finnish male participants in 1995 during a 2-day Finlandia Ski Race in Lahti, Finland. Acute cardiovascular responses were estimated by measuring the heart rate during exercise. The responses of the autonomic nervous system were estimated by measuring the heart rates during the orthostatic test. The musculoskeletal responses were estimated by measuring the perceived pains, flexibility, functional strength, use of elastic energy and oedemic changes of the lower extremities. Hormonal responses were estimated from the urinary excretion of catecholamines, and the concentrations of serum cortisol, testosterone, luteinizing (LH and follicle stimulating hormone (FSH. Mood states were assessed with the Profile of Mood States (POMS questionnaire. Daily walking time was 7-10 hours while the skiing time was 3 hours. Average heart rate during walking was 59% and skiing 87% of maximum heart rate. Morning heart rate in the supine position increased progressively through the marching period but not through the skiing experiment. After the first day, perceived pain increased significantly and remained at a similarly increased level until the end of the exercise period. Leg measurements showed no signs of oedema, decreases in flexibility, or functional strength. Catecholamine excretion rates during marches indicated cumulatively increased

  8. Assessment of pose repeatability and specimen repositioning of a robotic joint testing platform.

    Science.gov (United States)

    El Daou, H; Lord, B; Amis, A; Rodriguez Y Baena, F

    2017-09-01

    This paper describes the quantitative assessment of a robotic testing platform, consisting of an industrial robot and a universal force-moment sensor, via the design of fixtures used to hold the tibia and femur of cadaveric knees. This platform was used to study the contributions of different soft tissues and the ability of implants and reconstruction surgeries to restore normal joint functions, in previously published literature. To compare different conditions of human joints, it is essential to reposition specimens with high precision after they have been removed for a surgical procedure. Methods and experiments carried out to determine the pose repeatability and measure errors in repositioning specimens are presented. This was achieved using an optical tracking system (fusion Track 500, Atracsys Switzerland) to measure the position and orientation of bespoke rigid body markers attached to the tibial and femoral pots after removing and reinstalling them inside the rigs. The pose repeatability was then evaluated by controlling the robotic platform to move a knee joint repeatedly to/from a given pose while tracking the position and orientation of a rigid body marker attached to the tibial fixture. The results showed that the proposed design ensured a high repeatability in repositioning the pots with standard deviations for the computed distance and angle between the pots at both ends of the joint equal to 0.1mm, 0.01mm, 0.13° and 0.03° for the tibial and femoral fixtures respectively. Therefore, it is possible to remove and re-setup a joint with high precision. The results also showed that the errors in repositioning the robotic platform (that is: specimen path repeatability) were 0.11mm and 0.12°, respectively. Copyright © 2017. Published by Elsevier Ltd.

  9. Repeating earthquakes recorded by Liaoning Regional Seismograph Network

    Institute of Scientific and Technical Information of China (English)

    LI Yu-tong; WU Zhong-liang; JIANG Chang-sheng; LI Guang-ping

    2008-01-01

    In the list of 'repeating pairs' or 'doublets' of earthquakes in China identified by Schaff and Richards using tele-seismic waveform cross-correlation, there were 23 repeating pairs located in Liaoning Province. In this study the waveforms of these events were cross-correlated using records from Liaoning Regional Seismograph Network (LRSN), and the 'repeating events' in the sense of regional waveform cross-correlation were obtained. The result was compared with that of Schaff and Richards and was used for the assessment of the seismic phase picking and event location practice of LRSN. The result shows that 'repeating events' in the sense of teleseismic waveform cross-correlation and those in the sense of regional waveform cross-correlation have significant difference, al-though with some overlap. However, the overall assessment of the location accuracy and the phase pick errors of LRSN by using these two sets of 'repeating events', respectively, provides similar results, while 'repeating events' in the sense of regional waveform cross-correlation seem to be better performing in such an assessment. With the assumption that the separation between the 'repeaters' be less than 1 km, the uncertainty in routine earthquake location of LRSN is estimated to be below 5 km, with the average of 2 km. In the observational bulletins of LRSN the time error in phase picking is estimated to be within±Is for 94% Pg readings and for 88% Sg readings.

  10. Exploring the repeat protein universe through computational protein design.

    Science.gov (United States)

    Brunette, T J; Parmeggiani, Fabio; Huang, Po-Ssu; Bhabha, Gira; Ekiert, Damian C; Tsutakawa, Susan E; Hura, Greg L; Tainer, John A; Baker, David

    2015-12-24

    A central question in protein evolution is the extent to which naturally occurring proteins sample the space of folded structures accessible to the polypeptide chain. Repeat proteins composed of multiple tandem copies of a modular structure unit are widespread in nature and have critical roles in molecular recognition, signalling, and other essential biological processes. Naturally occurring repeat proteins have been re-engineered for molecular recognition and modular scaffolding applications. Here we use computational protein design to investigate the space of folded structures that can be generated by tandem repeating a simple helix-loop-helix-loop structural motif. Eighty-three designs with sequences unrelated to known repeat proteins were experimentally characterized. Of these, 53 are monomeric and stable at 95 °C, and 43 have solution X-ray scattering spectra consistent with the design models. Crystal structures of 15 designs spanning a broad range of curvatures are in close agreement with the design models with root mean square deviations ranging from 0.7 to 2.5 Å. Our results show that existing repeat proteins occupy only a small fraction of the possible repeat protein sequence and structure space and that it is possible to design novel repeat proteins with precisely specified geometries, opening up a wide array of new possibilities for biomolecular engineering.

  11. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans

    Science.gov (United States)

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-01-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature (P < 0.05). This result indicated that repeated local muscle cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  12. Improving repeatability by improving quality

    Energy Technology Data Exchange (ETDEWEB)

    Ronen, Shuki; Ackers, Mark; Schlumberger, Geco-Prakla; Brink, Mundy

    1998-12-31

    Time lapse (4-D) seismic is a promising tool for reservoir characterization and monitoring. The method is apparently simple: to acquire data repeatedly over the same reservoir, process and interpret the data sets, then changes between the data sets indicate changes in the reservoir. A problem with time lapse seismic data is that reservoirs are a relatively small part of the earth and important reservoir changes may cause very small differences to the time lapse data. The challenge is to acquire and process economical time lapse data such that reservoir changes can be detected above the noise of varying acquisition and environment. 7 refs., 9 figs.

  13. Coordinated hybrid automatic repeat request

    KAUST Repository

    Makki, Behrooz

    2014-11-01

    We develop a coordinated hybrid automatic repeat request (HARQ) approach. With the proposed scheme, if a user message is correctly decoded in the first HARQ rounds, its spectrum is allocated to other users, to improve the network outage probability and the users\\' fairness. The results, which are obtained for single- and multiple-antenna setups, demonstrate the efficiency of the proposed approach in different conditions. For instance, with a maximum of M retransmissions and single transmit/receive antennas, the diversity gain of a user increases from M to (J+1)(M-1)+1 where J is the number of users helping that user.

  14. The CRISPRdb database and tools to display CRISPRs and to generate dictionaries of spacers and repeats

    OpenAIRE

    Vergnaud Gilles; Grissa Ibtissem; Pourcel Christine

    2007-01-01

    Abstract Background In Archeae and Bacteria, the repeated elements called CRISPRs for "clustered regularly interspaced short palindromic repeats" are believed to participate in the defence against viruses. Short sequences called spacers are stored in-between repeated elements. In the current model, motifs comprising spacers and repeats may target an invading DNA and lead to its degradation through a proposed mechanism similar to RNA interference. Analysis of intra-species polymorphism shows t...

  15. Automatization and familiarity in repeated checking

    NARCIS (Netherlands)

    Dek, Eliane C P; van den Hout, Marcel A.; Giele, Catharina L.; Engelhard, Iris M.

    2014-01-01

    Repeated checking paradoxically increases memory uncertainty. This study investigated the underlying mechanism of this effect. We hypothesized that as a result of repeated checking, familiarity with stimuli increases, and automatization of the checking procedure occurs, which should result in decrea

  16. CDC Vital Signs: Preventing Repeat Teen Births

    Science.gov (United States)

    ... file Error processing SSI file Preventing Repeat Teen Births Recommend on Facebook Tweet Share Compartir On this ... Too many teens, ages 15–19, have repeat births. Nearly 1 in 5 births to teens, ages ...

  17. Expanded complexity of unstable repeat diseases

    OpenAIRE

    Polak, Urszula; McIvor, Elizabeth; Dent, Sharon Y.R.; Wells, Robert D.; Napierala, Marek.

    2012-01-01

    Unstable Repeat Diseases (URDs) share a common mutational phenomenon of changes in the copy number of short, tandemly repeated DNA sequences. More than 20 human neurological diseases are caused by instability, predominantly expansion, of microsatellite sequences. Changes in the repeat size initiate a cascade of pathological processes, frequently characteristic of a unique disease or a small subgroup of the URDs. Understanding of both the mechanism of repeat instability and molecular consequen...

  18. Analysis of Simple Sequence Repeats in Genomes of Rhizobia

    Institute of Scientific and Technical Information of China (English)

    GAO Ya-mei; HAN Yi-qiang; TANG Hui; SUN Dong-mei; WANG Yan-jie; WANG Wei-dong

    2008-01-01

    Simple sequence repeats (SSRs) or microsatellites, as genetic markers, are ubiquitous in genomes of various organisms. The analysis of SSR in rhizobia genome provides useful information for a variety of applications in population genetics of rhizobia. We analyzed the occurrences, relative abundance, and relative density of SSRs, the most common in Bradyrhizobium japonicum, Mesorhizobium loti, and Sinorhizobium meliloti genomes se-quenced in the microorganisms tandem repeats database, and SSRs in the three species genomes were compared with each other. The result showed that there were 1 410, 859, and 638 SSRs in B. japonicum, M. loti, and 5. meliloti genomes, respectively. In the genomes of B. japonicum, M. loti, and 5. meliloti, tetranucleotide, pentanucleotide, and hexanucleotide repeats were more abundant and indicated higher mutation rates in these species. The least abundance was mononucleotide repeat. The SSRs type and distribution were similar among these species.

  19. Ising Model Reprogramming of a Repeat Protein's Equilibrium Unfolding Pathway.

    Science.gov (United States)

    Millership, C; Phillips, J J; Main, E R G

    2016-05-08

    Repeat proteins are formed from units of 20-40 aa that stack together into quasi one-dimensional non-globular structures. This modular repetitive construction means that, unlike globular proteins, a repeat protein's equilibrium folding and thus thermodynamic stability can be analysed using linear Ising models. Typically, homozipper Ising models have been used. These treat the repeat protein as a series of identical interacting subunits (the repeated motifs) that couple together to form the folded protein. However, they cannot describe subunits of differing stabilities. Here we show that a more sophisticated heteropolymer Ising model can be constructed and fitted to two new helix deletion series of consensus tetratricopeptide repeat proteins (CTPRs). This analysis, showing an asymmetric spread of stability between helices within CTPR ensembles, coupled with the Ising model's predictive qualities was then used to guide reprogramming of the unfolding pathway of a variant CTPR protein. The designed behaviour was engineered by introducing destabilising mutations that increased the thermodynamic asymmetry within a CTPR ensemble. The asymmetry caused the terminal α-helix to thermodynamically uncouple from the rest of the protein and preferentially unfold. This produced a specific, highly populated stable intermediate with a putative dimerisation interface. As such it is the first step in designing repeat proteins with function regulated by a conformational switch. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. 47 CFR 97.205 - Repeater station.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Repeater station. 97.205 Section 97.205... SERVICE Special Operations § 97.205 Repeater station. (a) Any amateur station licensed to a holder of a Technician, General, Advanced or Amateur Extra Class operator license may be a repeater. A holder of...

  1. 47 CFR 22.1015 - Repeater operation.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Repeater operation. 22.1015 Section 22.1015... Offshore Radiotelephone Service § 22.1015 Repeater operation. Offshore central stations may be used as repeater stations provided that the licensee is able to maintain control of the station, and in...

  2. ProtRepeatsDB: a database of amino acid repeats in genomes

    Directory of Open Access Journals (Sweden)

    Chauhan Virander S

    2006-07-01

    Full Text Available Abstract Background Genome wide and cross species comparisons of amino acid repeats is an intriguing problem in biology mainly due to the highly polymorphic nature and diverse functions of amino acid repeats. Innate protein repeats constitute vital functional and structural regions in proteins. Repeats are of great consequence in evolution of proteins, as evident from analysis of repeats in different organisms. In the post genomic era, availability of protein sequences encoded in different genomes provides a unique opportunity to perform large scale comparative studies of amino acid repeats. ProtRepeatsDB http://bioinfo.icgeb.res.in/repeats/ is a relational database of perfect and mismatch repeats, access to which is designed as a resource and collection of tools for detection and cross species comparisons of different types of amino acid repeats. Description ProtRepeatsDB (v1.2 consists of perfect as well as mismatch amino acid repeats in the protein sequences of 141 organisms, the genomes of which are now available. The web interface of ProtRepeatsDB consists of different tools to perform repeat s; based on protein IDs, organism name, repeat sequences, and keywords as in FASTA headers, size, frequency, gene ontology (GO annotation IDs and regular expressions (REGEXP describing repeats. These tools also allow formulation of a variety of simple, complex and logical queries to facilitate mining and large-scale cross-species comparisons of amino acid repeats. In addition to this, the database also contains sequence analysis tools to determine repeats in user input sequences. Conclusion ProtRepeatsDB is a multi-organism database of different types of amino acid repeats present in proteins. It integrates useful tools to perform genome wide queries for rapid screening and identification of amino acid repeats and facilitates comparative and evolutionary studies of the repeats. The database is useful for identification of species or organism specific

  3. RTVue傅里叶光学相干断层扫描仪测量角膜参数的重复性和准确性评价%Repeatability and accuracy of corneal parameters measured by RTVue Fourier-domain optical coherence topography

    Institute of Scientific and Technical Information of China (English)

    华焱军; 黄锦海; 潘超; 王勤美

    2013-01-01

    parameters was less than 1%.The Cronbach Alpha and ICC were both more than 0.9 except 0.802(ICC)of the Rposterior/Ranterior.SimK was (0.27±0.34) D higher than Km,and Knet was (0.73±0.37) D lower than Km.SimK was (1.01 ±0.11) D higher than K and all the differences showed a statistical significance (P<0.001).There were close positive correlations between SimK and Km,Knet and Km,SimK and Knet(all r ≥ 0.976,P<0.001).The Bland-Altman analysis showed a poor agreement between SimK and Km,Knet and Km,SimK and Knet.Conclusions The RTVue FD-OCT measuring corneal curvature and CCT performes good repeatability.The Sim K obtained by RTVue FD-OCT is slightly greater than that obtained by corneal topography,and the Rposterior/Ranterior obtained by RTVue FD-OCT is slightly lower than that from Gullstrand model eye.These results offer a basis for establishing a more accurate standardized model eye.

  4. Application of multivariate Meta-analytical model in Meta-analysis of repeated measures outcomes%生存资料的二次研究系列之六:多元Meta分析模型在重复测量结局Meta分析中的应用

    Institute of Scientific and Technical Information of China (English)

    孟详喻; 田国祥; 周新雨; 孙竹; 李胜; 曾宪涛

    2016-01-01

    Repeated measures data are one of major data types in medical studies, especially in those related to prognosis. Correlation exists among multiple measures values corresponding to different time points, thus separate analyses for single outcome in secondary studies, e.g. Meta-analysis, should be avoided since bias might be introduced and the multivariate Meta-analysis model which well manages dependence across effect sizes is recommended. In this article, a multivariate Meta-analytical model was presented to merge multiple binary repeated measures outcomes, as well as actualized in R software through example analysis.%目的:重复测量资料是医学研究尤其是预后相关研究中重要的资料类型之一。不同时间点重复测量值之间存在相关性,若在二次研究如Meta分析中分开分析的结果可能存在偏倚,采用多元Meta分析模型能够有效避免因分开分析而导致的偏倚。本文介绍使用多元Meta分析模型合并多个二分类重复测量结局的方法,并通过实例分析演示如何在R软件中实现。

  5. Importance of muscle power variables in repeated and single sprint performance in soccer players.

    Science.gov (United States)

    López-Segovia, Manuel; Dellal, Alexandre; Chamari, Karim; González-Badillo, Juan José

    2014-03-27

    This study examined the relationship between lower body power and repeated as well as single sprint performance in soccer players. The performance of nineteen male soccer players was examined. The first testing session included the countermovement jump (CMJL) and the progressive full squat (FSL), both with external loads. Power in the CMJL and FSL was measured with each load that was lifted. The second session included a protocol of 40-m repeated sprints with a long recovery period (2 min). The number of sprints executed until there was a 3% decrease in performance for the best 40-m sprint time was recorded as a repeated sprint index (RSI). The RSI was moderately associated with power output relative to body mass in the CMJL and FSL (r = 0.53/0.54, p ≤ 0.05). The most and least powerful players (determined by FSL) showed significant differences in the RSI (9.1 ± 4.2 vs. 6.5 ± 1.6) and 10 m sprint time (p ± 0.01). Repeated and single sprints are associated with relatively lower body power in soccer players.

  6. Temporal asthma patterns using repeated questionnaires over 13 years in a large French cohort of women.

    Directory of Open Access Journals (Sweden)

    Margaux Sanchez

    Full Text Available Variable expression is one aspect of the heterogeneity of asthma. We aimed to define a variable pattern, which is relevant in general health epidemiological cohorts. Our objectives were to assess whether: 1 asthma patterns defined using simple asthma questions through repeated measurements could reflect disease variability 2 these patterns may further be classified according to asthma severity/control. Among 70,428 French women, we used seven questionnaires (1992-2005 and a comprehensive reimbursement database (2004-2009 to define three reliable asthma patterns based on repeated positive answers to the ever asthma attack question: "never asthma" (n = 64,061; "inconsistent" ("yes" followed by "no", n = 3,514; "consistent" (fully consistent positive answers, n = 2,853. The "Inconsistent" pattern was related to both long-term (childhood-onset asthma with remission in adulthood and short-term (reported asthma attack in the last 12 months, associated with asthma medication asthma variability, showing that repeated questions are relevant markers of the variable expression of asthma. Furthermore, in this pattern, the number of positive responses (1992-2005 predicted asthma drug consumption in subsequent years, a marker of disease severity. The "Inconsistent" pattern is a phenotype that may capture the variable expression of asthma. Repeated answers, even to a simple question, are too often neglected.

  7. An integrated quantum repeater at telecom wavelength with single atoms in optical fiber cavities

    Science.gov (United States)

    Uphoff, Manuel; Brekenfeld, Manuel; Rempe, Gerhard; Ritter, Stephan

    2016-03-01

    Quantum repeaters promise to enable quantum networks over global distances by circumventing the exponential decrease in success probability inherent in direct photon transmission. We propose a realistic, functionally integrated quantum-repeater implementation based on single atoms in optical cavities. Entanglement is directly generated between the single-atom quantum memory and a photon at telecom wavelength. The latter is collected with high efficiency and adjustable temporal and spectral properties into a spatially well-defined cavity mode. It is heralded by a near-infrared photon emitted from a second, orthogonal cavity. Entanglement between two remote quantum memories can be generated via an optical Bell-state measurement, while we propose entanglement swapping based on a highly efficient, cavity-assisted atom-atom gate. Our quantum-repeater scheme eliminates any requirement for wavelength conversion such that only a single system is needed at each node. We investigate a particular implementation with rubidium and realistic parameters for Fabry-Perot cavities based on hbox {CO}_2 laser-machined optical fibers. We show that the scheme enables the implementation of a rather simple quantum repeater that outperforms direct entanglement generation over large distances and does not require any improvements in technology beyond the state of the art.

  8. Facial emotion recognition in myotonic dystrophy type 1 correlates with CTG repeat expansion

    Directory of Open Access Journals (Sweden)

    Stefan Winblad

    2009-04-01

    Full Text Available We investigated the ability of patients with myotonic dystrophy type 1 to recognise basic facial emotions. We also explored the relationship between facial emotion recognition, neuropsychological data, personality, and CTG repeat expansion data in the DM-1 group. In total, 50 patients with DM-1 (28 women and 22 men participated, with 41 healthy controls. Recognition of facial emotional expressions was assessed using photographs of basic emotions. A set of tests