WorldWideScience

Sample records for repeated incomplete ultrasound

  1. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  2. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  3. Safety Validation of Repeated Blood-Brain Barrier Disruption Using Focused Ultrasound.

    Science.gov (United States)

    Kobus, Thiele; Vykhodtseva, Natalia; Pilatou, Magdalini; Zhang, Yongzhi; McDannold, Nathan

    2016-02-01

    The purpose of this study was to investigate the effects on the brain of multiple sessions of blood-brain barrier (BBB) disruption using focused ultrasound (FUS) in combination with micro-bubbles over a range of acoustic exposure levels. Six weekly sessions of FUS, using acoustical pressures between 0.66 and 0.80 MPa, were performed under magnetic resonance guidance. The success and degree of BBB disruption was estimated by signal enhancement of post-contrast T1-weighted imaging of the treated area. Histopathological analysis was performed after the last treatment. The consequences of repeated BBB disruption varied from no indications of vascular damage to signs of micro-hemorrhages, macrophage infiltration, micro-scar formations and cystic cavities. The signal enhancement on the contrast-enhanced T1-weighted imaging had limited value for predicting small-vessel damage. T2-weighted imaging corresponded well with the effects on histopathology and could be used to study treatment effects over time. This study demonstrates that repeated BBB disruption by FUS can be performed with no or limited damage to the brain tissue. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  5. Repeatability and interobserver reproducibility of Artemis-2 high-frequency ultrasound in determination of human corneal thickness

    Directory of Open Access Journals (Sweden)

    Ogbuehi KC

    2012-05-01

    Full Text Available Kelechi C Ogbuehi, Uchechukwu L OsuagwuOutpatient Clinic, Department of Optometry, King Saud University, Riyadh, Kingdom of Saudi ArabiaBackground: The purpose of this study was to assess the repeatability and limits of agreement of corneal thickness values measured by a high-frequency ultrasound (Artemis-2, hand-held ultrasound pachymeter (DGH-500 and a specular microscope (SP-3000P.Methods: Central corneal thickness (CCT was analyzed in this prospective randomized study that included 32 patients (18 men and 14 women aged 21–24 years. Measurements were obtained in two sessions, one week apart, by two examiners with three devices in a randomized order. Nine measurements were taken (three with each device on one randomly selected eye of each patient in each measurement session. The coefficient of repeatability and interobserver reproducibility for the values of each method were calculated. The limits of agreement between techniques were also evaluated.Results: There were no significant differences in CCT values between sessions for each of the three devices (P > 0.05. The repeatability coefficients for the Artemis-2 (±8 µm/±9 µm were superior to those of the SP-3000P (±9 µm/±11 µm and DGH 500 (±12 µm/±12 µm in session 1/session 2 respectively, while the interobserver reproducibility index (differences between session 1 and session 2 was superior for the SP-3000P (±17 µm with respect to DHG-500 (±29 µm and the Artemis-2 (±31 µm. In session 1 and session 2, the limits of agreement between the techniques were 35 µm to -31 µm and 34 to -20 µm, respectively, for DGH-500 versus Artemis-2, 73 µm to 3 µm and 60 µm to 9 µm for Artemis-2 versus SP-3000P, and 58 µm to 22 µm and 72 µm to 10 µm for DGH-500 versus SP-3000P comparisons. The DGH-500 and Artemis-2 gave similar values (P > 0.05 in both sessions, but both (Artemis-2 and DGH-500 values were significantly greater than that of the SP-3000P (P < 0.05 in both sessions

  6. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  7. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  8. High Efficacy of Repeating Colonoscopy by an Advanced Endoscopist after an Incomplete Colonoscopy

    OpenAIRE

    Ana Ponte; Rolando Pinho; Adélia Rodrigues; Luísa Proença; Joana Silva; Jaime P. Rodrigues; Mafalda Sousa; João Carlos Silva; João Carvalho

    2018-01-01

    Background and Aims: This study aims to evaluate the role of an advanced endoscopist to study the entire colon after an incomplete colonoscopy. Methods: All patients with an elective incomplete colonoscopy performed under deep sedation in our department between January 2010 and October 2016 were included. Patients with a colonic stenosis, an inadequate bowel preparation, or a colonoscopy performed without deep sedation were excluded. Included patients were followed up to evaluate if and what ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  10. Incomplete dicephalous conjoined twins: prenatal US and MRI findings

    International Nuclear Information System (INIS)

    Salvador, Diego; Ruata, Maria I.; Ruiz Lascano, Diogenes; Travella, Claudio; Tinti, Maria E.

    2002-01-01

    The authors report a case of incomplete dicephali conjoined twins, with prenatal diagnostic by ultrasound scan and confirmed with nuclear magnetic resonance. In this case the fetus presented two complete heads and necks, two parallel columns up to the coccyx, one single body, two complete arms and two complete legs. Thorax and abdominal organs were not double, however the heart had more than four cavities. This abnormality appears when the zygote division happens after the day 14 from fertilization and it is unable to cause the fission, resulting in an incomplete division. This kind of conjoined twins have practically no chance of surviving, due to the large number of shared organs. The prenatal diagnosis is important to separate these cases from those with a chance of living with surgical intervention. (author)

  11. Past incompleteness of a bouncing multiverse

    International Nuclear Information System (INIS)

    Vilenkin, Alexander; Zhang, Jun

    2014-01-01

    According to classical GR, Anti-de Sitter (AdS) bubbles in the multiverse terminate in big crunch singularities. It has been conjectured, however, that the fundamental theory may resolve these singularities and replace them by nonsingular bounces. This may have important implications for the beginning of the multiverse. Geodesics in cosmological spacetimes are known to be past-incomplete, as long as the average expansion rate along the geodesic is positive, but it is not clear that the latter condition is satisfied if the geodesic repeatedly passes through crunching AdS bubbles. We investigate this issue in a simple multiverse model, where the spacetime consists of a patchwork of FRW regions. The conclusion is that the spacetime is still past-incomplete, even in the presence of AdS bounces

  12. Past incompleteness of a bouncing multiverse

    Energy Technology Data Exchange (ETDEWEB)

    Vilenkin, Alexander; Zhang, Jun, E-mail: vilenkin@cosmos.phy.tufts.edu, E-mail: jun.zhang@tufts.edu [Institute of Cosmology, Department of Physics and Astronomy, Tufts University, Medford, MA 02155 (United States)

    2014-06-01

    According to classical GR, Anti-de Sitter (AdS) bubbles in the multiverse terminate in big crunch singularities. It has been conjectured, however, that the fundamental theory may resolve these singularities and replace them by nonsingular bounces. This may have important implications for the beginning of the multiverse. Geodesics in cosmological spacetimes are known to be past-incomplete, as long as the average expansion rate along the geodesic is positive, but it is not clear that the latter condition is satisfied if the geodesic repeatedly passes through crunching AdS bubbles. We investigate this issue in a simple multiverse model, where the spacetime consists of a patchwork of FRW regions. The conclusion is that the spacetime is still past-incomplete, even in the presence of AdS bounces.

  13. Repeatability of popliteal blood flow and lower limb vascular conductance at rest and exercise during body tilt using Doppler ultrasound

    International Nuclear Information System (INIS)

    Villar, R; Hughson, R L

    2013-01-01

    We tested the data repeatability for popliteal blood flow velocity (PBV), popliteal arterial diameter (AD pop ), popliteal blood flow (PBF) and lower limb vascular conductance (VC) at rest and exercise in three body positions, two work rates and two inspired oxygen fractions. Fifteen, eleven and ten healthy volunteers participated in the three phases of the studies. Resting protocols were performed in horizontal (HOR), 35° head-down tilt (HDT) and 45° head-up tilt (HUT) for 5 min in each body position. Participants also exercised at lower and higher power outputs (repeated plantar flexion contractions at 20% and 30% maximal voluntary contraction, respectively) in HOR, HDT and HUT and in normoxia (21%O 2 ) and hypoxia (14%O 2 ) with the same work rates and body positions. PBV and AD pop were measured by ultrasound to determine PBF, and VC was estimated by dividing PBF by muscle perfusion pressure (MPP). PBV, AD pop , PBF and VC were not different, demonstrated good agreement and consistency between the two days of testing during both rest and exercise conditions regardless of body position. Therefore, these data support the utilization of Doppler and echo Doppler ultrasound as a reproducible method to measure PBV and AD pop and consequently estimate PBF and VC responses in such conditions. (paper)

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  15. Achieving a complete colonic evaluation in patients with incomplete colonoscopy is worth the effort.

    Science.gov (United States)

    Ridolfi, Timothy J; Valente, Michael A; Church, James M

    2014-03-01

    Patients with an incomplete colonoscopy are potentially at risk for missed lesions. The purpose of this work was to identify the percentage of patients completing colonic evaluation after incomplete colonoscopy, the manner in which the evaluation was completed, and the incidence of significant pathology. This was a retrospective analysis of prospectively collected data. The study was conducted in an outpatient colonoscopy clinic in the colorectal surgery department of a tertiary referral center. Patients included those undergoing incomplete colonoscopy from a database of 25,645 colonoscopies performed from 1982 to 2009. Procedures aimed at completing colorectal evaluation were included in the study. Reason for incompletion, secondary study, its success, and findings were measured. A total of 242 patients with incomplete colonoscopies were identified; 166 (69%) were women. The average age of patients was 59 years. Most frequent causes for incomplete colonoscopy were inadequate preparation (34%), pain (30%), and tortuosity (20%). The scope could not pass the splenic flexure in 165 patients (71%). A total of 218 patients (90%) were offered completion studies, and 179 patients (82%) complied. Seventy-three of 82 patients who had a surveillance colonoscopy had a follow-up (89%), compared with 72 (87%) of 83 with symptoms and 40 (74%) of 54 who had a screening. Barium enema (BE) was performed in 74 (41%), repeat colonoscopy in 71 (40%), CT colonography in 17 (9%), and colonoscopy under general anesthesia in 9 patients (5%). Resection with intraoperative/perioperative colonoscopy was required in 8 patients (4%). Repeat colonoscopy found 32 lesions (24 tubular adenomas, 4 tubulovillous adenomas, and 4 sessile serrated polyps) in 17 patients (24%). Radiology demonstrated new abnormalities in 11 (12%) of 91 patients, prompting 7 colonoscopies. In 3 patients, colonoscopy showed an inverted appendix, a tubulovillous adenoma, and a sigmoid stricture. Overall, clinically

  16. On the reproducibility of expert-operated and robotic ultrasound acquisitions.

    Science.gov (United States)

    Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir

    2017-06-01

    We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

  17. Comparison of dynamic ultrasound and stress radiology for assessment of inferior glenohumeral laxity in asymptomatic shoulders

    International Nuclear Information System (INIS)

    Cheng, S.C.; Wallace, W.A.; Hulse, D.; Fairbairn, K.J.; Clarke, M.

    2008-01-01

    To determine the level of agreement between dynamic ultrasound imaging and stress radiography used for the measurement of inferior glenohumeral laxity in asymptomatic shoulders, and to determine the repeatability of the dynamic ultrasound technique. Using a custom-made stress device to apply an inferior displacement force of 90 N, we assessed 20 asymptomatic male subjects for inferior glenohumeral laxity, using stress radiography and dynamic ultrasound. Paired differences between the two methods were evaluated by the 95% limits of agreement method. At a separate session, 19 subjects had inferior glenohumeral laxity assessed by two observers, using dynamic ultrasound. Inter- and intra-observer repeatability was determined for the ultrasound technique. The mean [± standard deviation (SD)] inferior translation was 4.7 ± 4.1 mm by stress radiography and 4.4 ± 2.3 mm by dynamic ultrasound. The 95% limits of agreement showed good agreement between the two methods. The paired difference between the two measurement methods varied with the magnitude of the measurement (P < 0.001). Intra-observer repeatability of dynamic ultrasound was determined by the use of intra-class correlation coefficients and was 0.94 and 0.89 for the two investigators. Inter-observer repeatability was 0.85. The standard error of the measurement was 0.60 mm and 0.66 mm, for repeated measurements by the two investigators, and 0.85 mm between investigators. Repeatability coefficients demonstrated excellent consistency of measurement between sessions and good consistency between observers. Dynamic ultrasound is a valid and reproducible method for the assessment and quantification of inferior glenohumeral laxity. (orig.)

  18. Motion Detection in Ultrasound Image-Sequences Using Tensor Voting

    Science.gov (United States)

    Inba, Masafumi; Yanagida, Hirotaka; Tamura, Yasutaka

    2008-05-01

    Motion detection in ultrasound image sequences using tensor voting is described. We have been developing an ultrasound imaging system adopting a combination of coded excitation and synthetic aperture focusing techniques. In our method, frame rate of the system at distance of 150 mm reaches 5000 frame/s. Sparse array and short duration coded ultrasound signals are used for high-speed data acquisition. However, many artifacts appear in the reconstructed image sequences because of the incompleteness of the transmitted code. To reduce the artifacts, we have examined the application of tensor voting to the imaging method which adopts both coded excitation and synthetic aperture techniques. In this study, the basis of applying tensor voting and the motion detection method to ultrasound images is derived. It was confirmed that velocity detection and feature enhancement are possible using tensor voting in the time and space of simulated ultrasound three-dimensional image sequences.

  19. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  20. Incomplete fusion studies

    International Nuclear Information System (INIS)

    Singh, B.P.

    2011-01-01

    In order to study the incomplete fusion reaction dynamics at energies ≅ 4-7 MeV/nucleon, several experiments have been carried out using accelerator facilities available in India. The measurements presented here cover a wide range of projectile-target combinations and enhance significantly our knowledge about incomplete fusion reaction dynamics. Here, the three sets of measurements have been presented; (i) excitation functions, (ii) forward recoil range distributions and (iii) the spin distributions. The first evidence of these reactions has been obtained from the measurement and analysis of excitation functions for xn/αxn/2αxn-channels. The measured excitation functions have been analyzed within the framework of compound nucleus model. The results obtained indicate the occurrence of fusion incompleteness at low beam energies. However, in order to determine the relative contribution of complete and incomplete fusion reaction processes, the recoil range distributions of the heavy residues have also been measured and analyzed within the framework of breakup fusion model which confirmed the fusion incompleteness in several heavy ion reactions involving α-emitting reaction channels. Further, in order to study the role of l-values in these reactions the spin distributions of the residues populated in case of complete and incomplete channels have been measured and are found to be distinctly different. The analysis of the data on spin distribution measurements indicate that the mean values of driving input angular momenta associated with direct-α-emitting (incomplete fusion) channels are higher than that observed for fusion-evaporation xn or α-emitting (complete fusion) channels, and is found to increase with direct α-multiplicity in the forward cone. One of the important conclusions drawn in the present work is that, there is significant incomplete fusion contribution even at energies slightly above the barrier. Further, the projectile structure has been found to

  1. Pictorial essay: Role of ultrasound in failed carpal tunnel decompression

    Directory of Open Access Journals (Sweden)

    Rajesh Botchu

    2012-01-01

    Full Text Available USG has been used for the diagnosis of carpal tunnel syndrome. Scarring and incomplete decompression are the main causes for persistence or recurrence of symptoms. We performed a retrospective study to assess the role of ultrasound in failed carpal tunnel decompression. Of 422 USG studies of the wrist performed at our center over the last 5 years, 14 were for failed carpal tunnel decompression. Scarring was noted in three patients, incomplete decompression in two patients, synovitis in one patient, and an anomalous muscle belly in one patient. No abnormality was detected in seven patients. We present a pictorial review of USG findings in failed carpal tunnel decompression.

  2. Pictorial essay: Role of ultrasound in failed carpal tunnel decompression.

    Science.gov (United States)

    Botchu, Rajesh; Khan, Aman; Jeyapalan, Kanagaratnam

    2012-01-01

    USG has been used for the diagnosis of carpal tunnel syndrome. Scarring and incomplete decompression are the main causes for persistence or recurrence of symptoms. We performed a retrospective study to assess the role of ultrasound in failed carpal tunnel decompression. Of 422 USG studies of the wrist performed at our center over the last 5 years, 14 were for failed carpal tunnel decompression. Scarring was noted in three patients, incomplete decompression in two patients, synovitis in one patient, and an anomalous muscle belly in one patient. No abnormality was detected in seven patients. We present a pictorial review of USG findings in failed carpal tunnel decompression.

  3. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    OBJECTIVES: The purpose of this study was to investigate the detection rate of prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsies (mp-MRI-bx) in patients with prior negative transrectal ultrasound biopsy (TRUS-bx) sessions without previous experience of this......-RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...

  4. Decomposition of incomplete fusion

    International Nuclear Information System (INIS)

    Sobotka, L.B.; Sarantities, D.G.; Stracener, D.W.; Majka, Z.; Abenante, V.; Semkow, T.M.; Hensley, D.C.; Beene, J.R.; Halbert, M.L.

    1989-01-01

    The velocity distribution of fusion-like products formed in the reaction 701 MeV 28 Si+ 100 Mo is decomposed into 26 incomplete fusion channels. The momentum deficit of the residue per nonevaporative mass unit is approximately equal to the beam momentum per nucleon. The yields of the incomplete fusion channels correlate with the Q-value for projectile fragmentation rather than that for incomplete fusion. The backward angle multiplicities of light particles and heavy ions increase with momentum transfer, however, the heavy ion multiplicities also depend on the extent of the fragmentation of the incomplete fusion channel. These data indicate that at fixed linear momentum transfer, increased fragmentation of the unfused component is related to a reduced transferred angular momentum. 22 refs., 6 figs., 1 tab

  5. Emergency point-of-care ultrasound applications

    African Journals Online (AJOL)

    pneumothoraces led to the development of the extended FAST (EFAST) and can be used in abdominal (blunt) and chest (blunt and penetrating) trauma. The operator obtains six views to systematically evaluate the unstable trauma patient (Fig. 1). Ultrasound uses no contrast media and is rapid, repeatable, portable, non-.

  6. Ultrasound-enhanced nanotherapy of pancreatic cancer

    Science.gov (United States)

    Rapoport, N.; Nam, K.-H.; Christensen, D. A.; Kennedy, A. M.; Shea, J. E.; Scaife, C. L.

    2010-03-01

    The paper reports in vivo results of ultrasonic nanotherapy of orthotopically grown pancreatic cancer. Phase-shift paclitaxel (PTX) loaded perfluoropentane (PFP) nanoemusions combined with tumor-directed ultrasound have been used with a considerable success for tumor-targeted chemotherapy of gemcitabin (GEM)-refractory pancreatic cancer (PC). The GEM-resistant pancreatic cancer proved sensitive to treatment by a micellar PTX formulation Genexol PM (GEN) andor nanodroplet PTX formulation ndGEN. Due to increased permeability of tumor blood vessels, drug-loaded nanodroplets accumulated in the tumor via passive targeting, which was confirmed by ultrasound imaging. Nanodroplets converted into microbubbles in situ under the action of tumor-directed 1-MHz therapeutic ultrasound. The strongest therapeutic effect was observed for the combination therapy by PTX-loaded nanodroplets, GEM and ultrasound (ndGEN+GEM+ultrasound). This combination therapy resulted in a spectacular tumor regression and in some cases complete tumor resolution. Moreover, formation of metastases was dramatically decreased and ascitis generation was completely suppressed. However for all animal groups, local tumor recurrence was observed after the completion of the treatment indicating that some cancer cells survived the treatment. The recurrent tumors proved more resistant to the repeated therapy than initial tumors.

  7. Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.

    Science.gov (United States)

    Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J

    2018-01-01

    Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.

  8. Echogenic rim of hepatic hemangioma on abdominal ultrasound

    International Nuclear Information System (INIS)

    Park, Sang Woo; Kang, Chang Ho; Kim, Jin Hyoung; Kim, Chul Joong; Cheong, In Joo; Kim, Baek Hyun; Cha, Sang Hoon; Park, Cheol Min; Chung, Kyu Byung

    2000-01-01

    To investigate the association between the size of the hepatic hemangioma and the shape and thickness of the echogenic rim of hepatic hemangioma on abdominal ultrasound. We examined 47 cases (M:F=24:23, mean age 47.1) of hepatic hemangiomas with echogenic rim on abdominal ultrasound during the past 2 years. Radiologic findings were retrospectively reviewed in terms of completeness and thickness of echogenic rim. If echogenic rim showed even thickness, it was measured. But if not, the maximum and minimum thickness of the rim was measured. The association between the size of hemangioma and the completeness and thickness of the echogenic rim were analyzed statistically. Of the 47 cases, complete echogenic rim and incomplete echogenic rim were obtained in 29 (62%) and 18 (38%) cases, respectively. Twenty-two cases of hemangioma were less than 2 cm in diameter, and their distribution according to echogenic rim were as follows: complete echogenic rim (17/20, 91% mean thickness 2.2 cm) and uneven thickness with complete echogenic rim (3/20, 15%, range:2.0-6.1 mm). Twenty-five hemangiomas were larger than 2 cm in diameter and their distribution according to echogenic rim were as follows: complete echogenic rim (n=9, 34%), incomplete echogenic rim (n=16, 64%0,even thickness with complete echogenic rim (3/9, 33%, mean thickness 2.2 mm) and uneven thickness with complete echogenic rim (6/9,67%, range: 2.0-7.6 mm). In statistical analysis, hemangiomas more than 2 cm in diameter were more likely to have incomplete echogenic rim (p<0.05) than those of less than 2 cm; hemangiomas more than with more than 2 cm in diameter and complete echogenic rim showed uneven thickness of echogenic rim (p<0.05), more often than those of less than 2 cm diameter. Hemangiomas with more than 2 cm in diameter showed more frequent incomplete echogenic rim than those of less than 2 cm in diameter, which had more frequent complete echogenic rim. Hemangiomas with complete echogenic rim and even rim

  9. The optimization of low specific speed centrifugal pump based on incomplete sensitivities

    International Nuclear Information System (INIS)

    Zhang, R H; Zheng, K; Shi, F X; Yao, L H

    2012-01-01

    In this research, the optimization method for low specific speed centrifugal pump impeller based on incomplete sensitivities was proposed. The main feature of the algorithm is that it avoids solving the flow field repeatedly in one optimization cycle in finite difference method and it avoids solving the adjoint equation in adjoint method. The blade meridional plan is considered as constant, and the blade camber line was parameterize by Taylor function. The coefficients in the Taylor function were taken as the control variable. The moment acting on the blade was considered as the objective function. With the incomplete sensitivities we can get the gradient of the objective function with respect to the control variable easily, and the blade shape can be renewed according to the inverse direction of the gradient. We will find the optimum design when the objective function is minimized. The computational cost is greatly reduced. The calculation cases show that the proposed theory and method is rotational.

  10. Item calibration in incomplete testing designs

    Directory of Open Access Journals (Sweden)

    Norman D. Verhelst

    2011-01-01

    Full Text Available This study discusses the justifiability of item parameter estimation in incomplete testing designs in item response theory. Marginal maximum likelihood (MML as well as conditional maximum likelihood (CML procedures are considered in three commonly used incomplete designs: random incomplete, multistage testing and targeted testing designs. Mislevy and Sheenan (1989 have shown that in incomplete designs the justifiability of MML can be deduced from Rubin's (1976 general theory on inference in the presence of missing data. Their results are recapitulated and extended for more situations. In this study it is shown that for CML estimation the justification must be established in an alternative way, by considering the neglected part of the complete likelihood. The problems with incomplete designs are not generally recognized in practical situations. This is due to the stochastic nature of the incomplete designs which is not taken into account in standard computer algorithms. For that reason, incorrect uses of standard MML- and CML-algorithms are discussed.

  11. Matriculation Research Report: Incomplete Grades; Data & Analysis.

    Science.gov (United States)

    Gerda, Joe

    The policy on incomplete grades at California's College of the Canyons states that incompletes may only be given under circumstances beyond students' control and that students must make arrangements with faculty prior to the end of the semester to clear the incomplete. Failure to complete an incomplete may result in an "F" grade. While…

  12. Quantitative muscle ultrasound versus quantitative MRI in facioscapulohumeral dystrophy

    NARCIS (Netherlands)

    Janssen, B.H.; Pillen, S.; Voet, N.B.M.; Heerschap, A.; Engelen, B.G.M. van; Alfen, N. van

    2014-01-01

    Background: Ultrasound and MR imaging are non-invasive methods that can be performed repeatedly and without discomfort. In the assessment of neuromuscular disorders it is unknown if they hold complementary information. In this study we tested this for patients with facioscapulohumeral muscular

  13. A repeat-until-success quantum computing scheme

    Energy Technology Data Exchange (ETDEWEB)

    Beige, A [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom); Lim, Y L [DSO National Laboratories, 20 Science Park Drive, Singapore 118230, Singapore (Singapore); Kwek, L C [Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542, Singapore (Singapore)

    2007-06-15

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes.

  14. A repeat-until-success quantum computing scheme

    International Nuclear Information System (INIS)

    Beige, A; Lim, Y L; Kwek, L C

    2007-01-01

    Recently we proposed a hybrid architecture for quantum computing based on stationary and flying qubits: the repeat-until-success (RUS) quantum computing scheme. The scheme is largely implementation independent. Despite the incompleteness theorem for optical Bell-state measurements in any linear optics set-up, it allows for the implementation of a deterministic entangling gate between distant qubits. Here we review this distributed quantum computation scheme, which is ideally suited for integrated quantum computation and communication purposes

  15. Ultrasound-guided continuous phrenic nerve block for persistent hiccups.

    NARCIS (Netherlands)

    Renes, S.H.; Geffen, G.J. van; Rettig, H.C.; Gielen, M.J.M.; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Phrenic nerve block can be performed and repeated if necessary for persistent hiccups, when conservative and pharmacological treatment is unsuccessful. We report the first description of an in-plane ultrasound (US)-guided phrenic nerve block (PhNB) with a catheter, after US investigation

  16. Ultrasound detection of placenta accreta in the first trimester of pregnancy.

    Science.gov (United States)

    Rahimi-Sharbaf, Fatemeh; Jamal, Ashraf; Mesdaghinia, Elaheh; Abedzadeh-Kalahroudi, Masoumeh; Niroomanesh, Shirin; Atoof, Fatemeh

    2014-06-01

    Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester. To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy. In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination. Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively. Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy.

  17. Immediate Emergency Department Diagnosis of Pyloric Stenosis with Point-of-care Ultrasound

    Directory of Open Access Journals (Sweden)

    Nicole Dorinzi

    2017-11-01

    Full Text Available A 15-day-old male who was born at term presented with non-bilious projectile vomiting. He was nontoxic and his abdomen was benign without masses. Point-of-care ultrasound (POCUS showed hypertrophic pyloric stenosis (HPS. Typical findings include target sign; pyloric muscle thickness greater than three millimeters (mm; channel length greater than 15–18 mm; and lack of gastric emptying. The patient was admitted; consultative ultrasound (US was negative, but repeated 48 hours later for persistent vomiting. This second US was interpreted as HPS, which was confirmed surgically. Pyloromyotomy was successful. Few reports describe POCUS by general emergency physicians to diagnose HPS. Here, we emphasize the value in repeat US for patients with persistent symptoms.

  18. Ultrasound guided electrocoagulation in patients with chronic non-insertional Achilles tendinopathy

    DEFF Research Database (Denmark)

    Boesen, M Ilum; Torp-Pedersen, S; Koenig, M Juhl

    2006-01-01

    High resolution colour Doppler ultrasound shows intratendinous Doppler activity in patients with chronic Achilles tendinopathy. Treatment of this neovascularisation with sclerosing therapy seems to relieve the pain. However, the procedure often has to be repeated....

  19. Intra-biliary contrast-enhanced ultrasound for evaluating biliary obstruction during percutaneous transhepatic biliary drainage: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Er-jiao [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Su, Zhong-zhen; Li, Kai; Ren, Jie; Guo, Huan-yi [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China)

    2012-12-15

    Objectives: The aimed of this study was to investigate the value of intra-biliary contrast-enhanced ultrasound (IB-CEUS) for evaluating biliary obstruction during percutaneous transhepatic biliary drainage (PTBD). Materials and methods: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison. Results: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P < 0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80). Conclusion: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.

  20. Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

    Directory of Open Access Journals (Sweden)

    Jorge J

    2013-02-01

    Full Text Available J Jorge,1 JL Rosado,2 JA Díaz-Rey,1 JM González-Méijome11Clinical and Experimental Optometry Research Laboratory, Center of Physics (Optometry, School of Sciences, University of Minho, Braga, 2Opticlinic, Lisboa, PortugalBackground: The purpose of this study was to compare the accuracy of the new Sirius® Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT and anterior chamber depth (ACD with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively.Methods: CCT and ACD was measured in 50 right eyes from 50 healthy subjects using a Sirius Scheimpflug camera, SP100 ultrasound pachymetry, and US800 ultrasound biometry.Results: CCT measured with the Sirius was 546 ± 39 µm and 541 ± 35 µm with SP100 ultrasound pachymetry (P = 0.003. The difference was statistically significant (mean difference 4.68 ± 10.5 µm; limits of agreement −15.8 to 25.20 µm. ACD measured with the Sirius was 2.96 ± 0.3 mm compared with 3.36 ± 0.29 mm using US800 ultrasound biometry (P < 0.001. The difference was statistically significant (mean difference −0.40 ± 0.16 mm; limits of agreement −0.72 to 0.07 mm. When the ACD values obtained using ultrasound biometry were corrected according to the values for CCT measured by ultrasound, the agreement increased significantly between both technologies for ACD measurements (mean difference 0.15 ± 0.16 mm; limits of agreement −0.16 to 0.45 mm.Conclusion: CCT and ACD measured by Sirius and ultrasound methods showing good agreement between repeated measurements obtained in the same subjects (repeatability with either instrument. However, CCT and ACD values, even after correcting ultrasound ACD by subtracting the CCT value obtained with either technology should not be used interchangeably.Keywords: Scheimpflug corneal tomography, ultrasound biometry, ultrasound pachymetry, limits of agreement

  1. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  2. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  3. Incomplete information and fractal phase space

    International Nuclear Information System (INIS)

    Wang, Qiuping A.

    2004-01-01

    The incomplete statistics for complex systems is characterized by a so called incompleteness parameter ω which equals unity when information is completely accessible to our treatment. This paper is devoted to the discussion of the incompleteness of accessible information and of the physical signification of ω on the basis of fractal phase space. ω is shown to be proportional to the fractal dimension of the phase space and can be linked to the phase volume expansion and information growth during the scale refining process

  4. Diagnostic Accuracy of Secondary Ultrasound Exam in Blunt Abdominal Trauma

    International Nuclear Information System (INIS)

    Rajabzadeh Kanafi, Alireza; Giti, Masoumeh; Gharavi, Mohammad Hossein; Alizadeh, Ahmad; Pourghorban, Ramin; Shekarchi, Babak

    2014-01-01

    In stable patients with blunt abdominal trauma, accurate diagnosis of visceral injuries is crucial. To determine whether repeating ultrasound exam will increase the sensitivity of focused abdominal sonography for trauma (FAST) through revealing additional free intraperitoneal fluid in patients with blunt abdominal trauma. We performed a prospective observational study by performing primary and secondary ultrasound exams in blunt abdominal trauma patients. All ultrasound exams were performed by four radiology residents who had the experience of more than 400 FAST exams. Five routine intraperitoneal spaces as well as the interloop space were examined by ultrasound in order to find free fluid. All patients who expired or were transferred to the operating room before the second exam were excluded from the study. All positive ultrasound results were compared with intra-operative and computed tomography (CT) findings and/or the clinical status of the patients. Primary ultrasound was performed in 372 patients; 61 of them did not undergo secondary ultrasound exam; thus, were excluded from the study.Three hundred eleven patients underwent both primary and secondary ultrasound exams. One hundred and two of all patients were evaluated by contrast enhanced CT scan and 31 underwent laparotomy. The sensitivity of ultrasound exam in detecting intraperitoneal fluid significantly increased from 70.7% for the primary exam to 92.7% for the secondary exam. Examining the interloop space significantly improved the sensitivity of ultrasonography in both primary (from 36.6% to 70.7%) and secondary (from 65.9% to 92.7%) exams. Performing a secondary ultrasound exam in stable blunt abdominal trauma patients and adding interloop space scan to the routine FAST exam significantly increases the sensitivity of ultrasound in detecting intraperitoneal free fluid

  5. Factors associated with initial incomplete ablation for benign thyroid nodules after radiofrequency ablation: First results of CEUS evaluation.

    Science.gov (United States)

    Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen

    2017-01-01

    To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P 50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with

  6. Ultrasound-Assisted Enantioselective Esterification of Ibuprofen Catalyzed by a Flower-Like Nanobioreactor

    Directory of Open Access Journals (Sweden)

    Baiyi An

    2016-04-01

    Full Text Available A flower-like nanobioreactor was prepared for resolution of ibuprofen in organic solvents. Ultrasound irradiation has been used to improve the enzyme performance of APE1547 (a thermophilic esterase from the archaeon Aeropyrum pernix K1 in the enantioselective esterification. Under optimum reaction conditions (ultrasound power, 225 W; temperature, 45 °C; water activity, 0.21, the immobilized APE1547 showed an excellent catalytic performance (enzyme activity, 13.26 μmol/h/mg; E value, 147.1. After ten repeated reaction batches, the nanobioreactor retained almost 100% of its initial enzyme activity and enantioselectivity. These results indicated that the combination of the immobilization method and ultrasound irradiation can enhance the enzyme performance dramatically.

  7. Surgical fiducial segmentation and tracking for pose estimation based on ultrasound B-mode images.

    Science.gov (United States)

    Lei Chen; Kuo, Nathanael; Aalamifar, Fereshteh; Narrow, David; Coon, Devin; Prince, Jerry; Boctor, Emad M

    2016-08-01

    Doppler ultrasound is a non-invasive diagnostic tool for the quantitative measurement of blood flow. However, given that it provides velocity data that is dependent on the location and angle of measurement, repeat measurements to detect problems over time may require an expert to return to the same location. We therefore developed an image-guidance system based on ultrasound B-mode images that enables an inexperienced user to position the ultrasound probe at the same site repeatedly in order to acquire a comparable time series of Doppler readings. The system utilizes a bioresorbable fiducial and complementing software composed of the fiducial detection, key points tracking, probe pose estimation, and graphical user interface (GUI) modules. The fiducial is an echogenic marker that is implanted at the surgical site and can be detected and tracked during ultrasound B-mode screening. The key points on the marker can next be used to determine the pose of the ultrasound probe with respect to the marker. The 3D representation of the probe with its position and orientation are then displayed in the GUI for the user guidance. The fiducial detection has been tested on the data sets collected from three animal studies. The pose estimation algorithm was validated by five data sets collected by a UR5 robot. We tested the system on a plastisol phantom and showed that it can detect and track the fiducial marker while displaying the probe pose in real-time.

  8. The Role of Incompleteness in Commodity Futures Markets

    Directory of Open Access Journals (Sweden)

    Takashi eKanamura

    2015-10-01

    Full Text Available This paper proposes a convenience yield-based pricing for commodity futures, which embeds incompleteness of commodity futures markets in convenience yields. By using the pricing method, we conduct empirical analyses of the prices of WTI crude oil, heating oil, and natural gas futures traded on the NYMEX in order to assess the incompleteness of energy futures markets. We show that the fluctuation from the incompleteness is partly driven by the fluctuation from convenience yields. In addition, it is shown that the incompleteness of natural gas futures market is more highlighted than the incompleteness of WTI crude oil and heating oil futures markets. We apply the implied market price of risk from the NYMEX data to pricing an Asian call option written on WTI crude oil futures. Finally, we try to apply the market incompleteness analysis to the post-crisis periods after 2009.

  9. [Monitoring radiofrequency ablation by ultrasound temperature imaging and elastography under different power intensities].

    Science.gov (United States)

    Geng, Xiaonan; Li, Qiang; Tsui, Pohsiang; Wang, Chiaoyin; Liu, Haoli

    2013-09-01

    To evaluate the reliability of diagnostic ultrasound-based temperature and elasticity imaging during radiofrequency ablation (RFA) through ex vivo experiments. Procine liver samples (n=7) were employed for RFA experiments with exposures of different power intensities (10 and 50w). The RFA process was monitored by a diagnostic ultrasound imager and the information were postoperatively captured for further temperature and elasticity image analysis. Infrared thermometry was concurrently applied to provide temperature change calibration during the RFA process. Results from this study demonstrated that temperature imaging was valid under 10 W RF exposure (r=0.95), but the ablation zone was no longer consistent with the reference infrared temperature distribution under high RF exposures. The elasticity change could well reflect the ablation zone under a 50 W exposure, whereas under low exposures, the thermal lesion could not be well detected due to the limited range of temperature elevation and incomplete tissue necrosis. Diagnostic ultrasound-based temperature and elastography is valid for monitoring thr RFA process. Temperature estimation can well reflect mild-power RF ablation dynamics, whereas the elastic-change estimation can can well predict the tissue necrosis. This study provide advances toward using diagnostic ultrasound to monitor RFA or other thermal-based interventions.

  10. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  11. High-resolution ultrasound biomicroscopy for monitoring ovarian structures in mice

    Directory of Open Access Journals (Sweden)

    Singh Jaswant

    2009-07-01

    Full Text Available Abstract Background Until recently, the limit of spatial resolution of ultrasound systems has prevented characterization of structures Methods Experiment 1 was a pilot study to develop methods of immobilization (physical restraint vs. general anesthesia and determine technical factors affecting ovarian images using ultrasound bio-microscopy in rats vs. mice. The hair coat was removed over the thoraco-lumber area using depilation cream, and a highly viscous acoustic gel was applied while the animals were maintained in sternal recumbency. In Experiment 2, changes in ovarian structures during the estrous cycle were monitored by twice daily ultrasonography in 10 mice for 2 estrous cycles. Results Ovarian images were not distinct in rats due to attenuation of ultrasound waves. Physical restraint, without general anesthesia, was insufficient for immobilization in mice. By placing the transducer face over the dorsal flank, the kidney was visualized initially as a point of reference. A routine of moving the transducer a few millimetres caudo-laterally from the kidney was established to quickly and consistently localize the ovaries; the total time to scan both ovaries in a mouse was about 10 minutes. By comparing vaginal cytology with non-anesthetized controls, repeated exposure to anesthesia did not affect the estrous cycle. Temporal changes in the number of follicles in 3 different size categories support the hypothesis that follicles ≥ 20 microns develop in a wave-like fashion. Conclusion The mouse is a suitable model for the study of ovarian dynamics using transcutaneous ultrasound bio-microscopy. Repeated general anesthesia for examination had no apparent effect on the estrous cycle, and preliminary results revealed a wave-like pattern of ovarian follicle development in mice.

  12. The Effects of Simulation-based Transvaginal Ultrasound Training on Quality and Efficiency of Care

    DEFF Research Database (Denmark)

    Tolsgaard, Martin Grønnebæk; Ringsted, Charlotte; Rosthøj, Susanne

    2017-01-01

    , but no studies have examined its effects on quality and efficiency of care. METHODS: Trainees from 4 University Hospitals in East Denmark were included (N = 54). Participants were randomized to either simulation-based ultrasound training and clinical training (intervention group, n = 28), or to clinical training......, 33.5-55.1) and 19.8% (95% CI, 4.1-32.9) in the intervention and control group, respectively (P = 0.005). CONCLUSIONS: Simulation-based ultrasound training improved quality of care and reduced the need for repeated patient examination and trainee supervision.......OBJECTIVE: To explore the effect of adding simulation-based transvaginal ultrasound training to trainees' clinical training compared with only clinical training on quality of and efficiency of care. BACKGROUND: Simulation-based ultrasound training may be an effective adjunct to clinical training...

  13. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  14. Stochastic incompleteness of quantum mechanics

    International Nuclear Information System (INIS)

    Suppes, P.; Zanotti, M.

    1976-01-01

    This article brings out in as conceptually clear terms as possible what seems to be a major incompleteness in the probability theory of particles offered by classical quantum mechanics. The exact nature of this incompleteness is illustrated by consideration of some simple quantum-mechanical examples. In addition, these examples are contrasted with the fundamental assumptions of Brownian motion in classical physics on the one hand, and with a controversey of a deecade ago in mathematical physchology. The central claim is that clasical quantum mechanics is radically incomplete in its probabilistic account of the motion of particles. In the last part of the article the time-dependent joint distribution of position and momentum of the linear harmonic oscillator is derived, and it is shown how the apparently physically paradoxical statistical independence of position and momentum has a natural explanation. The explanation is given within the framework of the non-quantum-mechanical stochastic theory constructed for such oscillators. (Auth.)

  15. A new instrument to assess physician skill at thoracic ultrasound, including pleural effusion markup.

    Science.gov (United States)

    Salamonsen, Matthew; McGrath, David; Steiler, Geoff; Ware, Robert; Colt, Henri; Fielding, David

    2013-09-01

    To reduce complications and increase success, thoracic ultrasound is recommended to guide all chest drainage procedures. Despite this, no tools currently exist to assess proceduralist training or competence. This study aims to validate an instrument to assess physician skill at performing thoracic ultrasound, including effusion markup, and examine its validity. We developed an 11-domain, 100-point assessment sheet in line with British Thoracic Society guidelines: the Ultrasound-Guided Thoracentesis Skills and Tasks Assessment Test (UGSTAT). The test was used to assess 22 participants (eight novices, seven intermediates, seven advanced) on two occasions while performing thoracic ultrasound on a pleural effusion phantom. Each test was scored by two blinded expert examiners. Validity was examined by assessing the ability of the test to stratify participants according to expected skill level (analysis of variance) and demonstrating test-retest and intertester reproducibility by comparison of repeated scores (mean difference [95% CI] and paired t test) and the intraclass correlation coefficient. Mean scores for the novice, intermediate, and advanced groups were 49.3, 73.0, and 91.5 respectively, which were all significantly different (P < .0001). There were no significant differences between repeated scores. Procedural training on mannequins prior to unsupervised performance on patients is rapidly becoming the standard in medical education. This study has validated the UGSTAT, which can now be used to determine the adequacy of thoracic ultrasound training prior to clinical practice. It is likely that its role could be extended to live patients, providing a way to document ongoing procedural competence.

  16. Determination of the luminal diameter of the radial artery in man by high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1990-01-01

    measurements. By comparing the diameter of the reference object either filled with water or blood at 37 degrees C, the ultrasound velocity in human blood at 37 degrees C was calculated to be 1605 m/s. The intraobserver repeatability coefficients of in-vivo measurements of the radial artery in man were...... in the same range, whether measurements were repeated after 30 min (14%) or from day to day (12%). The interobserver repeatability coefficient was acceptable (15%) when the site of measurements was marked, whereas measurements without a mark resulted in a repeatability coefficient of 24%. The intravenous...

  17. Tracked "Pick-Up" Ultrasound for Robot-Assisted Minimally Invasive Surgery.

    Science.gov (United States)

    Schneider, Caitlin; Nguan, Christopher; Rohling, Robert; Salcudean, Septimiu

    2016-02-01

    We present a novel "pick-up" ultrasound transducer for intraabdominal robot-assisted minimally invasive surgery. Such a "pick-up" ultrasound transducer is inserted through an abdominal incision at the beginning of the procedure and remains in the abdominal cavity throughout, eliminating the need for a dedicated port or a patient bedside surgical assistant. The transducer has a handle that can be grasped in a repeatable manner using a da Vinci Prograsp tool, allowing the transducer to be accurately manipulated by the surgeon using the da Vinci Robot. This is one way to enable 3-D tracking of the transducer, and, thus, mapping of the vasculature. The 3-D vascular images can be used to register preoperative CT to intraoperative camera images. To demonstrate the feasibility of the approach, we use an ultrasound vessel phantom to register a CT surface model to extracted ultrasound vessel models. The 3-D vascular phantom images are generated by segmenting B-mode images and tracking the pick-up ultrasound transducer with the da Vinci kinematics, internal electromagnetic sensor, or visible fiducials suitable for camera tracking. Reconstruction results using da Vinci kinematics for tracking give a target registration error of 5.4 ± 1.7 mm.

  18. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  19. Incomplete convolutions in production and inventory models

    NARCIS (Netherlands)

    Houtum, van G.J.J.A.N.; Zijm, W.H.M.

    1997-01-01

    In this paper, we study incomplete convolutions of continuous distribution functions, as they appear in the analysis of (multi-stage) production and inventory systems. Three example systems are discussed where these incomplete convolutions naturally arise. We derive explicit, nonrecursive formulae

  20. Ultrasound in assisted reproduction: a call to fill the endometrial gap.

    Science.gov (United States)

    Hershko-Klement, Anat; Tepper, Ronnie

    2016-06-01

    Ultrasound offers essential details and an overall view of the anatomic features of the reproductive organs, as well as physiologic assessment. There is still a great gap, however, in our understanding and interpretation of endometrial sonographic findings. Endometrial thickness, growth, and sonographic patterns have been repeatedly tested and compared with pregnancy rates in IVF cycles, yielding conflicting results. Generally, the data accrued so far suggest refraining from clinical decisions based solely on endometrial thickness. The three-layer ultrasound pattern reflects normal follicular/proliferative dynamics, and its presence in the pre-hCG period was reported to carry a better outcome: Significantly higher clinical pregnancy rates were found in patients with this pattern on the day of hCG administration among IVF cohorts. Subendometrial contractility (endometrial "waves") offers a tool that can be used in cases of repeated implantation failure in patients reporting cramps around the planned time of embryo transfer, or as a reassuring modality to assess uterine quiescence during preparations for embryo transfer. We support the creation of an integrated endometrial score incorporating conservative endometrial measurements, endometrial-myometrial junction studies, and endometrial contractility, as well as new concepts that remain to be tested, such as endometrial surface area. Such scores may enable us to improve the effectiveness of endometrial ultrasound imaging in the clinical setting. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  2. Impact of an implanted neuroprosthesis on community ambulation in incomplete SCI.

    Science.gov (United States)

    Lombardo, Lisa M; Kobetic, Rudolf; Pinault, Gilles; Foglyano, Kevin M; Bailey, Stephanie N; Selkirk, Stephen; Triolo, Ronald J

    2018-03-01

    Test the effect of a multi-joint control with implanted electrical stimulation on walking after spinal cord injury (SCI). Single subject research design with repeated measures. Hospital-based biomechanics laboratory and user assessment of community use. Female with C6 AIS C SCI 30 years post injury. Lower extremity muscle activation with an implanted pulse generator and gait training. Walking speed, maximum distance, oxygen consumption, upper extremity (UE) forces, kinematics and self-assessment of technology. Short distance walking speed at one-year follow up with or without stimulation was not significantly different from baseline. However, average walking speed was significantly faster (0.22 m/s) with stimulation over longer distances than volitional walking (0.12 m/s). In addition, there was a 413% increase in walking distance from 95 m volitionally to 488 m with stimulation while oxygen consumption and maximum upper extremity forces decreased by 22 and 16%, respectively. Stimulation also produced significant (P ≤ 0.001) improvements in peak hip and knee flexion, ankle angle at foot off and at mid-swing. An implanted neuroprosthesis enabled a subject with incomplete SCI to walk longer distances with improved hip and knee flexion and ankle dorsiflexion resulting in decreased oxygen consumption and UE support. Further research is required to determine the robustness, generalizability and functional implications of implanted neuroprostheses for community ambulation after incomplete SCI.

  3. Incomplete linear tibial fractures in two horses

    International Nuclear Information System (INIS)

    Johnson, P.J.; Allhands, R.V.; Baker, G.J.; Boero, M.J.; Foreman, J.H.; Hyyppa, T.; Huhn, J.C.

    1988-01-01

    Incomplete linear tibial fractures were identified in two horses with the aid of scintigraphy. Both horses were treated successfully by strict stall confinement, and both returned to normal athletic activity. Scintigraphy can be used to facilitate the generally difficult diagnosis of incomplete tibial fractures

  4. Incomplete copolymer degradation of in situ chemotherapy.

    Science.gov (United States)

    Bourdillon, Pierre; Boissenot, Tanguy; Goldwirt, Lauriane; Nicolas, Julien; Apra, Caroline; Carpentier, Alexandre

    2018-02-17

    In situ carmustine wafers containing 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) are commonly used for the treatment of recurrent glioblastoma to overcome the brain-blood barrier. In theory, this chemotherapy diffuses into the adjacent parenchyma and the excipient degrades in maximum 8 weeks but no clinical data confirms this evolution, because patients are rarely operated again. A 75-year-old patient was operated twice for recurrent glioblastoma, and a carmustine wafer was implanted during the second surgery. Eleven months later, a third surgery was performed, revealing unexpected incomplete degradation of the wafer. 1H-Nuclear Magnetic Resonance was performed to compare this wafer to pure BCNU and to an unused copolymer wafer. In the used wafer, peaks corresponding to hydrophobic units of the excipient were no longer noticeable, whereas peaks of the hydrophilic units and traces of BCNU were still present. These surprising results could be related to the formation of a hydrophobic membrane around the wafer, thus interfering with the expected diffusion and degradation processes. The clinical benefit of carmustine wafers in addition to the standard radio-chemotherapy remains limited, and in vivo behavior of this treatment is not completely elucidated yet. We found that the wafer may remain after several months. Alternative strategies to deal with the blood-brain barrier, such as drug-loaded liposomes or ultrasound-opening, must be explored to offer larger drug diffusion or allow repetitive delivery.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  6. Suction v. conventional curettage in incomplete abortion

    African Journals Online (AJOL)

    Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. D. A. A. VERKUYL, C. A. CROWTHER .Abstract This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients ...

  7. The influence of external ultrasound on the histologic architecture of the organic capsule around smooth silicone implants: experimental study in rats.

    Science.gov (United States)

    Mendes, F H; Viterbo, F; DeLucca, L

    2008-05-01

    Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules. In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into "ultrasound" and "control" groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light. Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization. The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.

  8. Exploring the effects of gravity on tongue motion using ultrasound image sequences

    Science.gov (United States)

    Stone, Maureen; Crouse, Ulla; Sutton, Marty

    2002-05-01

    Our goal in the research was to explore the effect that gravity had on the vocal-tract system by using ultrasound data collected in the upright and supine positions. All potential subjects were given an ultrasound pretest to determine whether they could repeat a series of 3-4 words precise enough to allow an accurate series of images to be collected. Out of these potential subjects, approximately 5-7 subjects were eventually used in the research. The method of collecting ultrasound data required the immobilization of the patient by restraining their neck in a custom fitted neck restraint. The neck restraint held an ultrasound transducer positioned at a critical angle underneath the patients' lower jawbone, which served to reduce errors and increase image resolution. To accurately analyze the series of images collected from ultrasound imaging, the surfaces of the tongue were digitized and tongue motion was time-aligned across the upright and supine sequences. Comparisons between the upright and supine data were then made by using L2 norms to determine averages and differences regarding the behavior between the two positions. Curves and locations of the maximum and minimum differences will be discussed.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  11. Quantum Bertrand duopoly of incomplete information

    International Nuclear Information System (INIS)

    Qin Gan; Chen Xi; Sun Min; Du Jiangfeng

    2005-01-01

    We study Bertrand's duopoly of incomplete information. It is found that the effect of quantum entanglement on the outcome of the game is dramatically changed by the uncertainty of information. In contrast with the case of complete information where the outcome increases with entanglement, when information is incomplete the outcome is maximized at some finite entanglement. As a consequence, information and entanglement are both crucial factors that determine the properties of a quantum oligopoly

  12. Some Families of the Incomplete H-Functions and the Incomplete \\overline H -Functions and Associated Integral Transforms and Operators of Fractional Calculus with Applications

    Science.gov (United States)

    Srivastava, H. M.; Saxena, R. K.; Parmar, R. K.

    2018-01-01

    Our present investigation is inspired by the recent interesting extensions (by Srivastava et al. [35]) of a pair of the Mellin-Barnes type contour integral representations of their incomplete generalized hypergeometric functions p γ q and p Γ q by means of the incomplete gamma functions γ( s, x) and Γ( s, x). Here, in this sequel, we introduce a family of the relatively more general incomplete H-functions γ p,q m,n ( z) and Γ p,q m,n ( z) as well as their such special cases as the incomplete Fox-Wright generalized hypergeometric functions p Ψ q (γ) [ z] and p Ψ q (Γ) [ z]. The main object of this paper is to study and investigate several interesting properties of these incomplete H-functions, including (for example) decomposition and reduction formulas, derivative formulas, various integral transforms, computational representations, and so on. We apply some substantially general Riemann-Liouville and Weyl type fractional integral operators to each of these incomplete H-functions. We indicate the easilyderivable extensions of the results presented here that hold for the corresponding incomplete \\overline H -functions as well. Potential applications of many of these incomplete special functions involving (for example) probability theory are also indicated.

  13. A new version of an old modal incompleteness theorem

    NARCIS (Netherlands)

    Vosmaer, J.

    2010-01-01

    Thomason [5] showed that a certain modal logic L⊂ S4 is incomplete with respect to Kripke semantics. Later Gerson [3] showed that L is also incomplete with respect to neighborhood semantics. In this paper we show that L is in fact incomplete with respect to any class of complete Boolean algebras

  14. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  15. Indirect Reciprocity under Incomplete Observation

    Science.gov (United States)

    Nakamura, Mitsuhiro; Masuda, Naoki

    2011-01-01

    Indirect reciprocity, in which individuals help others with a good reputation but not those with a bad reputation, is a mechanism for cooperation in social dilemma situations when individuals do not repeatedly interact with the same partners. In a relatively large society where indirect reciprocity is relevant, individuals may not know each other's reputation even indirectly. Previous studies investigated the situations where individuals playing the game have to determine the action possibly without knowing others' reputations. Nevertheless, the possibility that observers of the game, who generate the reputation of the interacting players, assign reputations without complete information about them has been neglected. Because an individual acts as an interacting player and as an observer on different occasions if indirect reciprocity is endogenously sustained in a society, the incompleteness of information may affect either role. We examine the game of indirect reciprocity when the reputations of players are not necessarily known to observers and to interacting players. We find that the trustful discriminator, which cooperates with good and unknown players and defects against bad players, realizes cooperative societies under seven social norms. Among the seven social norms, three of the four suspicious norms under which cooperation (defection) to unknown players leads to a good (bad) reputation enable cooperation down to a relatively small observation probability. In contrast, the three trustful norms under which both cooperation and defection to unknown players lead to a good reputation are relatively efficient. PMID:21829335

  16. Gibbs' theorem for open systems with incomplete statistics

    International Nuclear Information System (INIS)

    Bagci, G.B.

    2009-01-01

    Gibbs' theorem, which is originally intended for canonical ensembles with complete statistics has been generalized to open systems with incomplete statistics. As a result of this generalization, it is shown that the stationary equilibrium distribution of inverse power law form associated with the incomplete statistics has maximum entropy even for open systems with energy or matter influx. The renormalized entropy definition given in this paper can also serve as a measure of self-organization in open systems described by incomplete statistics.

  17. Zero-sum games with incomplete definition

    International Nuclear Information System (INIS)

    Sprzeuzkouski, Alain

    1976-01-01

    In this research thesis, the author proposes three methods of resolution of incompletely defined games. According to the first one, combined strategies are introduced in an incompletely defined matrix game. According to the second and new one, a new strategy type (C-strategies) is defined for which the payoff function is always defined but not necessarily unequivocal. This leads to assume the existence of a referee who will decide the payoff assigned to players when they use these C-strategies which generate several possibilities. According to the last one, players are informed of the referee's choice. The three methods are compared, and the author shows that they are equivalent to the conventional method of resolution of matrix games in the case of a completely defined game. In another part, the author applied results obtained for incompletely defined matrix games to the case of multi-stage games with target

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  1. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  3. Evaluation of an Obstetric Ultrasound Curriculum for Midwives in Liberia.

    Science.gov (United States)

    Bentley, Suzanne; Hexom, Braden; Nelson, Bret P

    2015-09-01

    Point-of-care ultrasound is an effective tool for clinical decision making in low- and middle-income countries, but lack of trained providers is a barrier to its utility in these settings. In Liberia, given that midwives provide most prenatal care, it is hypothesized that training them in prenatal ultrasound through an intensive condensed training course is both feasible and practical. This quantitative prospective study of preobservational and postobservational assessment evaluated a 1-week ultrasound curriculum consisting of 4 modules, each comprising a didactic component, a practical session, and supervised patient encounters. A knowledge-based pretest and presurvey addressing prior use and comfort were administered. At the intervention conclusion, identical posttests and postsurveys were administered with an objective structured clinical examination (OSCE). The test, survey, and OSCE were repeated after 1 year. All scores and responses were tabulated, and qualitative analysis with paired t tests was performed. Thirty-one midwives underwent intervention and written evaluation, with 14 followed up at 1 year. Seventeen underwent the OSCE, with 8 retained at 1 year. There was a significant increase between pretest and immediate and 1-year posttest scores (36.6% versus 90% and 66%; P .05). Average overall comfort using ultrasound increased from presurvey to immediate postsurvey scores (from 1.8 to 3.8; P .05). Midwives in Liberia had very low baseline knowledge and comfort using ultrasound. A 1-week curriculum increased both short- and long-term knowledge and comfort and led to adequate overall OSCE scores that were retained at 1 year. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    Science.gov (United States)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  6. The topology of integrable systems with incomplete fields

    International Nuclear Information System (INIS)

    Aleshkin, K R

    2014-01-01

    Liouville's theorem holds for Hamiltonian systems with complete Hamiltonian fields which possess a complete involutive system of first integrals; such systems are called Liouville-integrable. In this paper integrable systems with incomplete Hamiltonian fields are investigated. It is shown that Liouville's theorem remains valid in the case of a single incomplete field, while if the number of incomplete fields is greater, a certain analogue of the theorem holds. An integrable system on the algebra sl(3) is taken as an example. Bibliography: 11 titles

  7. Osteoarthritis of the thumb carpometacarpal joint: Correlation of ultrasound appearances to disability and treatment response

    International Nuclear Information System (INIS)

    Mallinson, P.I.; Tun, J.K.; Farnell, R.D.; Campbell, D.A.; Robinson, P.

    2013-01-01

    Aim: To evaluate grading of thumb carpometacarpal joint (CMCJ) osteoarthritis (OA) using ultrasound, correlating findings with disability and treatment response. Materials and methods: Patients with symptomatic thumb OA attending for ultrasound-guided CMCJ steroid injection and a group of asymptomatic controls were recruited prospectively. Thumb CMCJ ultrasound was graded (osteophytes, joint-space narrowing, capsule size, and measured capsule size), and a Disabilities of the Arm Shoulder and Hand (DASH) questionnaire was completed for each patient. Symptomatic patients then underwent injection with DASH repeated 6 weeks post-treatment. Ultrasound features were correlated with the initial DASH disability score and response as defined by change in DASH 6 weeks after treatment. Results: Thirty-one patients with symptomatic OA and 37 asymptomatic controls were recruited. With the exception of osteophytes (p = 0.017), no statistically significant correlation was demonstrated between severity of ultrasound features and patient disability. However, all features demonstrated statistically significant higher grades in the symptomatic group compared to controls. Ultrasound grading did not have statistical correlation with treatment response. Conclusion: No correlation was found between the majority of ultrasound features and the clinical severity of OA or likely response to treatment. However, these features are significantly more common in the symptomatic population

  8. Incomplete resistance to coffee leaf rust (Hemileia vastatrix)

    NARCIS (Netherlands)

    Eskes, A.B.

    1983-01-01

    Incomplete resistance to coffee leaf rust ( Hemileia vastatrix ) may be of value in obtaining durable resistance, which is of great importance for the perennial coffee crop. Methods were developed to assess incomplete resistance to coffee leaf rust by using illustrated scales

  9. GPU-Based Simulation of Ultrasound Imaging Artifacts for Cryosurgery Training

    Science.gov (United States)

    Keelan, Robert; Shimada, Kenji

    2016-01-01

    This study presents an efficient computational technique for the simulation of ultrasound imaging artifacts associated with cryosurgery based on nonlinear ray tracing. This study is part of an ongoing effort to develop computerized training tools for cryosurgery, with prostate cryosurgery as a development model. The capability of performing virtual cryosurgical procedures on a variety of test cases is essential for effective surgical training. Simulated ultrasound imaging artifacts include reverberation and reflection of the cryoprobes in the unfrozen tissue, reflections caused by the freezing front, shadowing caused by the frozen region, and tissue property changes in repeated freeze–thaw cycles procedures. The simulated artifacts appear to preserve the key features observed in a clinical setting. This study displays an example of how training may benefit from toggling between the undisturbed ultrasound image, the simulated temperature field, the simulated imaging artifacts, and an augmented hybrid presentation of the temperature field superimposed on the ultrasound image. The proposed method is demonstrated on a graphic processing unit at 100 frames per second, on a mid-range personal workstation, at two orders of magnitude faster than a typical cryoprocedure. This performance is based on computation with C++ accelerated massive parallelism and its interoperability with the DirectX-rendering application programming interface. PMID:26818026

  10. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  13. Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task.

    Science.gov (United States)

    Downs, Matthew E; Buch, Amanda; Sierra, Carlos; Karakatsani, Maria Eleni; Teichert, Tobias; Chen, Shangshang; Konofagou, Elisa E; Ferrera, Vincent P

    2015-01-01

    Focused Ultrasound (FUS) coupled with intravenous administration of microbubbles (MB) is a non-invasive technique that has been shown to reliably open (increase the permeability of) the blood-brain barrier (BBB) in multiple in vivo models including non-human primates (NHP). This procedure has shown promise for clinical and basic science applications, yet the safety and potential neurological effects of long term application in NHP requires further investigation under parameters shown to be efficacious in that species (500 kHz, 200-400 kPa, 4-5 μm MB, 2 minute sonication). In this study, we repeatedly opened the BBB in the caudate and putamen regions of the basal ganglia of 4 NHP using FUS with systemically-administered MB over 4-20 months. We assessed the safety of the FUS with MB procedure using MRI to detect edema or hemorrhaging in the brain. Contrast enhanced T1-weighted MRI sequences showed a 98% success rate for openings in the targeted regions. T2-weighted and SWI sequences indicated a lack edema in the majority of the cases. We investigated potential neurological effects of the FUS with MB procedure through quantitative cognitive testing of' visual, cognitive, motivational, and motor function using a random dot motion task with reward magnitude bias presented on a touchpanel display. Reaction times during the task significantly increased on the day of the FUS with MB procedure. This increase returned to baseline within 4-5 days after the procedure. Visual motion discrimination thresholds were unaffected. Our results indicate FUS with MB can be a safe method for repeated opening of the BBB at the basal ganglia in NHP for up to 20 months without any long-term negative physiological or neurological effects with the parameters used.

  14. Cognition and Incomplete Contracts

    OpenAIRE

    Tirole, Jean

    2008-01-01

    Thinking about contingencies, designing covenants, and seeing through their implications is costly. Parties to a contract accordingly use heuristics and leave it incomplete. The paper develops a model of limited cognition and examines its consequences for contractual design. (JEL D23, D82, D86, L22)

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  16. The Surprise Examination Paradox and the Second Incompleteness Theorem

    OpenAIRE

    Kritchman, Shira; Raz, Ran

    2010-01-01

    We give a new proof for Godel's second incompleteness theorem, based on Kolmogorov complexity, Chaitin's incompleteness theorem, and an argument that resembles the surprise examination paradox. We then go the other way around and suggest that the second incompleteness theorem gives a possible resolution of the surprise examination paradox. Roughly speaking, we argue that the flaw in the derivation of the paradox is that it contains a hidden assumption that one can prove the consistency of the...

  17. Transient permeabilization of cell membranes by ultrasound-exposed microbubbles is related to formation of hydrogen peroxide.

    Science.gov (United States)

    Juffermans, L J M; Dijkmans, P A; Musters, R J P; Visser, C A; Kamp, O

    2006-10-01

    In the present study, we addressed the interactions among ultrasound, microbubbles, and living cells as well as consequent arising bioeffects. We specifically investigated whether hydrogen peroxide (H(2)O(2)) is involved in transient permeabilization of cell membranes in vitro after ultrasound exposure at low diagnostic power, in the presence of stable oscillating microbubbles, by measuring the generation of H(2)O(2) and Ca(2+) influx. Ultrasound, in the absence or presence of SonoVue microbubbles, was applied to H9c2 cells at 1.8 MHz with a mechanical index (MI) of 0.1 or 0.5 during 10 s. This was repeated every minute, for a total of five times. The production of H(2)O(2) was measured intracellularly with CM-H(2)DCFDA. Cell membrane permeability was assessed by measuring real-time changes in intracellular Ca(2+) concentration with fluo-4 using live-cell fluorescence microscopy. Ultrasound, in the presence of microbubbles, caused a significant increase in intracellular H(2)O(2) at MI 0.1 of 50% and MI 0.5 of 110% compared with control (P ultrasound exposure was completely blocked at MI 0.1 (P ultrasound-exposed microbubbles.

  18. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  19. How does incomplete fusion show up at slightly above barrier energies?

    Directory of Open Access Journals (Sweden)

    Prasad R.

    2012-02-01

    Full Text Available Experimental results on the onset of incomplete fusion at slightly above barrier energies are discussed in this paper. Spin-distributions of evaporation residues populated via complete and/or incomplete fusion of 12C,16O (Elab ≈ 4–7 MeV with 169Tm have been measured to probe associated ℓ–values. Particle (Z=1,2 – γ – coincidence technique has been used for channel selection. Entirely different entry state spin populations have been observed during the de-excitation of complete and incomplete composites. The complete fusion residues are found to be strongly fed over a broad spin range. While, a narrow range feeding for only high spin states has been observed in case of incomplete fusion residues. In the present work, incomplete fusion is shown to be a promising tool to populate high spin states in final reaction products. For better insight into the onset and strength of incomplete fusion, the relative contributions of complete and incomplete fusion have been deduced from the analysis of excitation functions and forward recoil ranges. A significant fraction of ICF has been observed even at energy as low as ≈ 7% above the barrier. The relative strengths of complete and incomplete fusion deduced from the analysis of forward-recoil-ranges and excitation functions complement each other. All the available results are discussed in light of the Morgenstern’s mass-asymmetry systematics. Incomplete fusion fraction is found to be large for more mass-asymmetric systems for individual projectiles, which points towards the projectile structure effect on incomplete fusion fraction. Experimentally measured forward ranges of recoils complement the existence of incomplete fusion at slightly above barrier energies, where more than one linear-momentum-transfer components associated with full- and/or partial-fusion of projectile(s have been observed. Present results conclusively demonstrate the possibility to selectively populate high spin states

  20. Pericoronal radiolucency associated with incomplete crown

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan (Korea, Republic of)

    2013-12-15

    The author experienced 8 cases of pericoronal radiolucency involving an incomplete tooth crown that had not developed to form the cemento-enamel junction, and the underdeveloped crown sometimes appeared to be floating within the radiolucency radiographically. The first impression was that these cystic lesions had odontogenic keratocysts, but half of them turned out to be dentigerous cysts histopathologically. There has been no report concerning odontogenic cysts involving an incompletely developed crown. The purpose of this paper is to report that dentigerous cysts may develop before the completion of the cemento-enamel junction of a developing crown.

  1. Pericoronal radiolucency associated with incomplete crown

    International Nuclear Information System (INIS)

    Nah, Kyung Soo

    2013-01-01

    The author experienced 8 cases of pericoronal radiolucency involving an incomplete tooth crown that had not developed to form the cemento-enamel junction, and the underdeveloped crown sometimes appeared to be floating within the radiolucency radiographically. The first impression was that these cystic lesions had odontogenic keratocysts, but half of them turned out to be dentigerous cysts histopathologically. There has been no report concerning odontogenic cysts involving an incompletely developed crown. The purpose of this paper is to report that dentigerous cysts may develop before the completion of the cemento-enamel junction of a developing crown.

  2. Classification and data acquisition with incomplete data

    Science.gov (United States)

    Williams, David P.

    In remote-sensing applications, incomplete data can result when only a subset of sensors (e.g., radar, infrared, acoustic) are deployed at certain regions. The limitations of single sensor systems have spurred interest in employing multiple sensor modalities simultaneously. For example, in land mine detection tasks, different sensor modalities are better-suited to capture different aspects of the underlying physics of the mines. Synthetic aperture radar sensors may be better at detecting surface mines, while infrared sensors may be better at detecting buried mines. By employing multiple sensor modalities to address the detection task, the strengths of the disparate sensors can be exploited in a synergistic manner to improve performance beyond that which would be achievable with either single sensor alone. When multi-sensor approaches are employed, however, incomplete data can be manifested. If each sensor is located on a separate platform ( e.g., aircraft), each sensor may interrogate---and hence collect data over---only partially overlapping areas of land. As a result, some data points may be characterized by data (i.e., features) from only a subset of the possible sensors employed in the task. Equivalently, this scenario implies that some data points will be missing features. Increasing focus in the future on using---and fusing data from---multiple sensors will make such incomplete-data problems commonplace. In many applications involving incomplete data, it is possible to acquire the missing data at a cost. In multi-sensor remote-sensing applications, data is acquired by deploying sensors to data points. Acquiring data is usually an expensive, time-consuming task, a fact that necessitates an intelligent data acquisition process. Incomplete data is not limited to remote-sensing applications, but rather, can arise in virtually any data set. In this dissertation, we address the general problem of classification when faced with incomplete data. We also address the

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  7. Incomplete factorization technique for positive definite linear systems

    International Nuclear Information System (INIS)

    Manteuffel, T.A.

    1980-01-01

    This paper describes a technique for solving the large sparse symmetric linear systems that arise from the application of finite element methods. The technique combines an incomplete factorization method called the shifted incomplete Cholesky factorization with the method of generalized conjugate gradients. The shifted incomplete Cholesky factorization produces a splitting of the matrix A that is dependent upon a parameter α. It is shown that if A is positive definite, then there is some α for which this splitting is possible and that this splitting is at least as good as the Jacobi splitting. The method is shown to be more efficient on a set of test problems than either direct methods or explicit iteration schemes

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  13. Neighborhood Hypergraph Based Classification Algorithm for Incomplete Information System

    Directory of Open Access Journals (Sweden)

    Feng Hu

    2015-01-01

    Full Text Available The problem of classification in incomplete information system is a hot issue in intelligent information processing. Hypergraph is a new intelligent method for machine learning. However, it is hard to process the incomplete information system by the traditional hypergraph, which is due to two reasons: (1 the hyperedges are generated randomly in traditional hypergraph model; (2 the existing methods are unsuitable to deal with incomplete information system, for the sake of missing values in incomplete information system. In this paper, we propose a novel classification algorithm for incomplete information system based on hypergraph model and rough set theory. Firstly, we initialize the hypergraph. Second, we classify the training set by neighborhood hypergraph. Third, under the guidance of rough set, we replace the poor hyperedges. After that, we can obtain a good classifier. The proposed approach is tested on 15 data sets from UCI machine learning repository. Furthermore, it is compared with some existing methods, such as C4.5, SVM, NavieBayes, and KNN. The experimental results show that the proposed algorithm has better performance via Precision, Recall, AUC, and F-measure.

  14. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    Science.gov (United States)

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  15. Repeated maternal intramuscular or intraamniotic erythromycin incompletely resolves intrauterine Ureaplasma parvum infection in a sheep model of pregnancy.

    Science.gov (United States)

    Kemp, Matthew W; Miura, Yuichiro; Payne, Matthew S; Watts, Rory; Megharaj, Smruthi; Jobe, Alan H; Kallapur, Suhas G; Saito, Masatoshi; Spiller, O Brad; Keelan, Jeffrey A; Newnham, John P

    2014-08-01

    Ureaplasma spp are the most commonly isolated microorganisms in association with preterm birth. Maternal erythromycin administration is a standard treatment for preterm prelabor rupture of membranes. There is little evidence of its effectiveness in eradicating Ureaplasma spp from the intrauterine cavity and fetus. We used a sheep model of intrauterine Ureaplasma spp infection to investigate the efficacy of repeated maternal intramuscular and intraamniotic erythromycin treatment to eradicate such an infection. Thirty ewes with singleton pregnancies received an intraamniotic injection of 10(7) color change units of erythromycin-sensitive Ureaplasma parvum serovar 3 at 55 days' gestation. At 116 days' gestation, 28 ewes with viable fetuses were randomized to receive (1) intraamniotic and maternal intramuscular saline solution treatment (n = 8), (2) single intraamniotic and repeated maternal intramuscular erythromycin treatment (n = 10), or (3) single maternal intramuscular and repeated intraamniotic erythromycin treatment (n = 10). Fetuses were surgically delivered at 125 days' gestation. Treatment efficacy was assessed by culture, quantitative polymerase chain reaction, and histopathologic evaluation. Animals treated with intraamniotic erythromycin had significantly less viable U parvum serovar 3 in the amniotic fluid at delivery. However, neither combination of maternal intramuscular and intraamniotic erythromycin treatment successfully cleared U parvum serovar 3 from the amniotic fluid or fetal tissues. Three de novo erythromycin-resistant U parvum isolates were identified in erythromycin-treated animals. Erythromycin treatment, given both to the ewe and into the amniotic cavity, fails to eradicate intrauterine and fetal U parvum serovar 3 infection and may lead to development of erythromycin resistant U parvum. Copyright © 2014 Mosby, Inc. All rights reserved.

  16. Goedel incompleteness theorems and the limits of their applicability. I

    International Nuclear Information System (INIS)

    Beklemishev, Lev D

    2011-01-01

    This is a survey of results related to the Goedel incompleteness theorems and the limits of their applicability. The first part of the paper discusses Goedel's own formulations along with modern strengthenings of the first incompleteness theorem. Various forms and proofs of this theorem are compared. Incompleteness results related to algorithmic problems and mathematically natural examples of unprovable statements are discussed. Bibliography: 68 titles.

  17. Goedel incompleteness theorems and the limits of their applicability. I

    Energy Technology Data Exchange (ETDEWEB)

    Beklemishev, Lev D [Steklov Mathematical Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2011-01-25

    This is a survey of results related to the Goedel incompleteness theorems and the limits of their applicability. The first part of the paper discusses Goedel's own formulations along with modern strengthenings of the first incompleteness theorem. Various forms and proofs of this theorem are compared. Incompleteness results related to algorithmic problems and mathematically natural examples of unprovable statements are discussed. Bibliography: 68 titles.

  18. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  20. Prevalence of Huntington's disease gene CAG trinucleotide repeat alleles in patients with bipolar disorder.

    Science.gov (United States)

    Ramos, Eliana Marisa; Gillis, Tammy; Mysore, Jayalakshmi S; Lee, Jong-Min; Alonso, Isabel; Gusella, James F; Smoller, Jordan W; Sklar, Pamela; MacDonald, Marcy E; Perlis, Roy H

    2015-06-01

    Huntington's disease is a neurodegenerative disorder characterized by motor, cognitive, and psychiatric symptoms that are caused by huntingtin gene (HTT) CAG trinucleotide repeat alleles of 36 or more units. A greater than expected prevalence of incompletely penetrant HTT CAG repeat alleles observed among individuals diagnosed with major depressive disorder raises the possibility that another mood disorder, bipolar disorder, could likewise be associated with Huntington's disease. We assessed the distribution of HTT CAG repeat alleles in a cohort of individuals with bipolar disorder. HTT CAG allele sizes from 2,229 Caucasian individuals diagnosed with DSM-IV bipolar disorder were compared to allele sizes in 1,828 control individuals from multiple cohorts. We found that HTT CAG repeat alleles > 35 units were observed in only one of 4,458 chromosomes from individuals with bipolar disorder, compared to three of 3,656 chromosomes from control subjects. These findings do not support an association between bipolar disorder and Huntington's disease. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Unpartitioned versus incompletely partitioned cochleae: radiologic differentiation.

    Science.gov (United States)

    Sennaroglu, Levent; Saatci, Isil

    2004-07-01

    In the process of evaluating our patients, we realized that the term "Mondini deformity" was being used to describe two different types of incomplete partition of the cochlea. THE First one consisted of an unpartitioned, completely empty cochlea where the interscalar septum and entire modiolus were absent, giving the cochlea a cystic appearance; a grossly dilated vestibule accompanied this lesion. The second pathology fitted the classic description of Mondini deformity, consisting of a normal basal turn and cystic apex (where the middle and apical turns form a cystic cavity), dilated vestibule, and enlarged vestibular aqueduct. This study was planned to investigate the differences between the two types of incomplete partition for inner ear malformations based on radiologic features. We conducted a retrospective review of temporal bone computed tomography (CT) findings. The subjects were 18 patients with profound bilateral sensorineural hearing loss who had high-resolution CT with contiguous 1-mm thick images obtained through the petrous bone in axial sections. The CT results were reviewed as incomplete partition type I (IP-I) and type II (IP-II). Incomplete partition type I (unpartitioned cochlea, cystic cochleovestibular malformation) is defined as a malformation in which the cochlea lacks the entire modiolus and interscalar septa, resulting in a cystic appearance and there is an accompanying grossly dilated vestibule. In incomplete partition type II (incompletely partitioned cochlea, the Mondini deformity), there is a cochlea comprised of a normal basal turn and cystic apex accompanied by a minimally dilated vestibule and enlarged vestibular aqueduct (VA). Measurements involving the cochlea, vestibule, vestibular aqueduct, and internal auditory canal (IAC) were done to determine the characteristic features of these pathologies. : Thirteen ears had IP-I and 18 ears had IP-II anomaly. The size of the cochleae in both anomalies showed no significant difference from

  2. Anencephaly with incomplete twinning (diprosopus).

    Science.gov (United States)

    Riccardi, V M; Bergmann, C A

    1977-10-01

    A case of diprosopus with anencephaly is presented. It is suggested that such concurrence of neural tube defects and incomplete twinning corroborates the notion that a single pathogenetic mechanism may be common to both neural tube defects and monozygotic twinning.

  3. Contractual Incompleteness, Unemployment, and Labour Market Segmentation

    DEFF Research Database (Denmark)

    Altmann, Steffen; Falk, Armin; Grunewald, Andreas

    2014-01-01

    This article provides evidence that involuntary unemployment, and the segmentation of labour markets into firms offering "good" and "bad" jobs, may both arise as a consequence of contractual incompleteness.We provide a simple model that illustrates how unemployment and market segmentation may...... jointly emerge as part of a market equilibrium in environments where work effort is not third-party verifiable. Using experimental labour markets that differ only in the verifiability of effort, we demonstrate empirically that contractual incompleteness can cause unemployment and segmentation. Our data...

  4. Esophageal squamous cell carcinoma presenting as submucosal lesion with repeatedly negative endoscopic biopsies

    Directory of Open Access Journals (Sweden)

    Narendra S Choudhary

    2016-01-01

    Full Text Available A 74-year-old male presented with dysphagia for 2 months. Computed tomography revealed irregular wall thickening of the esophagus at T3 to T5 level. He underwent gastroscopy which revealed a submucosal bulge with normal mucosa at 25 cm from incisors. Repeated biopsies were taken, all were negative for malignancy. The patient underwent endoscopic ultrasound, and fine-needle aspiration was taken which was suggestive for squamous cell carcinoma.

  5. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Incomplete Financial Markets and Jumps in Asset Prices

    DEFF Research Database (Denmark)

    Crès, Hervé; Markeprand, Tobias Ejnar; Tvede, Mich

    A dynamic pure-exchange general equilibrium model with uncertainty is studied. Fundamentals are supposed to depend continuously on states of nature. It is shown that: 1. if financial markets are complete, then asset prices vary continuously with states of nature, and; 2. if financial markets...... are incomplete, jumps in asset prices may be unavoidable. Consequently incomplete financial markets may increase volatility in asset prices significantly....

  7. Optical detection of ultrasound from optically rough surfaces using a custom CMOS sensor

    International Nuclear Information System (INIS)

    Achamfuo-Yeboah, S O; Light, R A; Sharpies, S D

    2015-01-01

    The optical detection of ultrasound from optically rough surfaces is severely limited when using a conventional interferometric or optical beam deflection (OBD) setup because the detected light is speckled. This means that complicated and expensive setups are required to detect ultrasound optically on rough surfaces. We present a CMOS integrated circuit that can detect laser ultrasound in the presence of speckle. The detector circuit is based on the simple knife edge detector. It is self-adapting and is fast, inxepensive, compact and robust. The CMOS circuit is implemented as a widefield array of 32×32 pixels. At each pixel the received light is compared with an adjacent pixel in order to determine the local light gradient. The result of this comparison is stored and used to connect each pixel to the positive or negative gradient output as appropriate (similar to a balanced knife edge detector). The perturbation of the surface due to ultrasound preserves the speckle distribution whilst deflecting it. The spatial disturbance of the speckle pattern due to the ultrasound is detected by considering each pair of pixels as a knife edge detector. The sensor can adapt itself to match the received optical speckle pattern in less than 0.1 μs, and then detect the ultrasound within 0.5 μs of adaptation. This makes it possible to repeatedly detect ultrasound from optically rough surfaces very quickly. The detector is capable of independent operation controlled by a local microcontroller, or it may be connected to a computer for more sophisticated configuration and control. We present the theory of its operation and discuss results validating the concept and operation of the device. We also present preliminary results from an improved design which grants a higher bandwidth, allowing for optical detection of higher frequency ultrasound

  8. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    Science.gov (United States)

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  9. Acceptance and use of the female condom among women with incomplete abortion in rural Tanzania

    DEFF Research Database (Denmark)

    Rasch, Vibeke; Yambesi, Fortunata; Kipingili, Rose

    2006-01-01

    BACKGROUND: This study describes the outcome of a postabortion care intervention aimed at introducing the female condom as a means of preventing women from having unwanted pregnancies and sexually transmitted infections (STIs)/HIV. METHODS: Postabortion contraceptive counseling and services were...... intended to use it again. CONCLUSION: Postabortion care programs provide an excellent entry point for introducing the female condom as a contraceptive method for the prevention of both repeat unwanted pregnancies and STI/HIV infection....... offered to 548 women admitted to the Kagera Regional Hospital for incomplete abortion. The counseling included information about STI/HIV and the use male or female condom. In total, 521 (95%) women accepted contraception. RESULTS: Contraceptive use was assessed 3 months after abortion among 475 (91...

  10. WE-AB-207A-02: John’s Equation Based Consistency Condition and Incomplete Projection Restoration Upon Circular Orbit CBCT

    International Nuclear Information System (INIS)

    Ma, J; Qi, H; Wu, S; Xu, Y; Zhou, L; Yan, H

    2016-01-01

    Purpose: In transmitted X-ray tomography imaging, projections are sometimes incomplete due to a variety of reasons, such as geometry inaccuracy, defective detector cells, etc. To address this issue, we have derived a direct consistency condition based on John’s Equation, and proposed a method to effectively restore incomplete projections based on this consistency condition. Methods: Through parameter substitutions, we have derived a direct consistency condition equation from John’s equation, in which the left side is only projection derivative of view and the right side is projection derivative of other geometrical parameters. Based on this consistency condition, a projection restoration method is proposed, which includes five steps: 1) Forward projecting reconstructed image and using linear interpolation to estimate the incomplete projections as the initial result; 2) Performing Fourier transform on the projections; 3) Restoring the incomplete frequency data using the consistency condition equation; 4) Performing inverse Fourier transform; 5) Repeat step 2)∼4) until our criteria is met to terminate the iteration. Results: A beam-blocking-based scatter correction case and a bad-pixel correction case were used to demonstrate the efficacy and robustness of our restoration method. The mean absolute error (MAE), signal noise ratio (SNR) and mean square error (MSE) were employed as our evaluation metrics of the reconstructed images. For the scatter correction case, the MAE is reduced from 63.3% to 71.7% with 4 iterations. Compared with the existing Patch’s method, the MAE of our method is further reduced by 8.72%. For the bad-pixel case, the SNR of the reconstructed image by our method is increased from 13.49% to 21.48%, with the MSE being decreased by 45.95%, compared with linear interpolation method. Conclusion: Our studies have demonstrated that our restoration method based on the new consistency condition could effectively restore the incomplete projections

  11. Intracapsular implant rupture: MR findings of incomplete shell collapse.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E

    1997-01-01

    The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.

  12. Robot-assisted automatic ultrasound calibration.

    Science.gov (United States)

    Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M

    2016-10-01

    Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated

  13. Incomplete immune recovery in HIV infection

    DEFF Research Database (Denmark)

    Gaardbo, Julie C; Hartling, Hans J; Gerstoft, Jan

    2012-01-01

    -infected patients do not achieve optimal immune reconstitution despite suppression of viral replication. These patients are referred to as immunological nonresponders (INRs). INRs present with severely altered immunological functions, including malfunction and diminished production of cells within lymphopoetic...... tissue, perturbed frequencies of immune regulators such as regulatory T cells and Th17 cells, and increased immune activation, immunosenescence, and apoptosis. Importantly, INRs have an increased risk of morbidity and mortality compared to HIV-infected patients with an optimal immune reconstitution....... Additional treatment to HAART that may improve immune reconstitution has been investigated, but results thus far have proved disappointing. The reason for immunological nonresponse is incompletely understood. This paper summarizes the known and unknown factors regarding the incomplete immune reconstitution...

  14. Challenges and regulatory considerations in the acoustic measurement of high-frequency (>20 MHz) ultrasound.

    Science.gov (United States)

    Nagle, Samuel M; Sundar, Guru; Schafer, Mark E; Harris, Gerald R; Vaezy, Shahram; Gessert, James M; Howard, Samuel M; Moore, Mary K; Eaton, Richard M

    2013-11-01

    This article examines the challenges associated with making acoustic output measurements at high ultrasound frequencies (>20 MHz) in the context of regulatory considerations contained in the US Food and Drug Administration industry guidance document for diagnostic ultrasound devices. Error sources in the acoustic measurement, including hydrophone calibration and spatial averaging, nonlinear distortion, and mechanical alignment, are evaluated, and the limitations of currently available acoustic measurement instruments are discussed. An uncertainty analysis of acoustic intensity and power measurements is presented, and an example uncertainty calculation is done on a hypothetical 30-MHz high-frequency ultrasound system. This analysis concludes that the estimated measurement uncertainty of the acoustic intensity is +73%/-86%, and the uncertainty in the mechanical index is +37%/-43%. These values exceed the respective levels in the Food and Drug Administration guidance document of 30% and 15%, respectively, which are more representative of the measurement uncertainty associated with characterizing lower-frequency ultrasound systems. Recommendations made for minimizing the measurement uncertainty include implementing a mechanical positioning system that has sufficient repeatability and precision, reconstructing the time-pressure waveform via deconvolution using the hydrophone frequency response, and correcting for hydrophone spatial averaging.

  15. Sensitivity of low-energy incomplete fusion to various entrance-channel parameters

    Science.gov (United States)

    Kumar, Harish; Tali, Suhail A.; Afzal Ansari, M.; Singh, D.; Ali, Rahbar; Kumar, Kamal; Sathik, N. P. M.; Ali, Asif; Parashari, Siddharth; Dubey, R.; Bala, Indu; Kumar, R.; Singh, R. P.; Muralithar, S.

    2018-03-01

    The disentangling of incomplete fusion dependence on various entrance channel parameters has been made from the forward recoil range distribution measurement for the 12C+175Lu system at ≈ 88 MeV energy. It gives the direct measure of full and/or partial linear momentum transfer from the projectile to the target nucleus. The comparison of observed recoil ranges with theoretical ranges calculated using the code SRIM infers the production of evaporation residues via complete and/or incomplete fusion process. Present results show that incomplete fusion process contributes significantly in the production of α xn and 2α xn emission channels. The deduced incomplete fusion probability (F_{ICF}) is compared with that obtained for systems available in the literature. An interesting behavior of F_{ICF} with ZP ZT is observed in the reinvestigation of incomplete fusion dependency with the Coulomb factor (ZPZT), contrary to the recent observations. The present results based on (ZPZT) are found in good agreement with recent observations of our group. A larger F_{ICF} value for 12C induced reactions is found than that for 13C, although both have the same ZPZT. A nonsystematic behavior of the incomplete fusion process with the target deformation parameter (β2) is observed, which is further correlated with a new parameter (ZP ZT . β2). The projectile α -Q-value is found to explain more clearly the discrepancy observed in incomplete fusion dependency with parameters ( ZPZT) and (ZP ZT . β2). It may be pointed out that any single entrance channel parameter (mass-asymmetry or (ZPZT) or β2 or projectile α-Q-value) may not be able to explain completely the incomplete fusion process.

  16. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  17. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-01-01

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p -2 ± 0.01 μm and 1.99 x 10 -2 ± 0.004 μm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  18. Repeatability of junctional zone measurements using three-dimensional transvaginal ultrasound in healthy, fertile women

    DEFF Research Database (Denmark)

    Rasmussen, Christina Kjærgaard; Glavind, Julie; Madsen, Lene Duch

    2016-01-01

    -observer repeatability was evaluated according to the Bland-Altman method and expressed as coefficient of repeatability (CoR). Results: Using 3D-TVS we visualised a thin and regular JZ in most women. The posterior uterine wall had the largest median (interquartile range; iqr) value of JZmax (5.2 (iqr 3.8-6.5)mm. Ten out....... Correlations between measurements were poor in the narrow range of JZ thickness. Conclusions: The JZ has an indistinct outline by 3D-TVS resulting in an error of JZ measurement within a broad range of ±2-4 mm, but reduced by average measurements. The thickness of JZ varied within a narrow range of this healthy......, fertile population and reliability measurements of JZ thickness has to be evaluated in women with a wider range of JZ thickness....

  19. Incomplete contract and divisional structures

    NARCIS (Netherlands)

    Bao, T.; Wang, Y.

    2009-01-01

    In this paper we want to analyze the internal divisional structure within an organi- zation in the framework of incomplete contract theory. We use the framework of Aghion and Tirole (1997) and define the managerial control structure as \\sequence of search". A key feature of this paper which

  20. Muscle ultrasound quantifies disease progression over time in infants and young boys with duchenne muscular dystrophy.

    Science.gov (United States)

    Zaidman, Craig M; Malkus, Elizabeth C; Connolly, Anne M

    2015-09-01

    Quantitative muscle ultrasound (QUS) in boys with Duchenne muscular dystrophy (DMD) shows increased echointensity as muscle is replaced with fat and fibrosis. Studies of quantitative ultrasound in infants/young boys with DMD over time have not been reported. We used calibrated muscle backscatter (cMB), a reproducible measure of ultrasound echointensity, to quantify muscle pathology in 5 young boys with DMD (ages 0.5-2.8 years) over 17-29 months. We compared the results with repeated assessments of function (n = 4) and with muscle ultrasound images from a cross-section of 6 male controls (0.6-3.1 years). cMB in boys with DMD increased (worsened) over time (P < 0.001), whereas function improved. After age 2 years, cMB in most (4 of 5) boys with DMD was higher than in any control. QUS measures disease progression in young boys with DMD despite functional improvements. QUS could be employed as an outcome measure for serial assessment of young boys with DMD. © 2015 Wiley Periodicals, Inc.

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  5. Incomplete fusion reactions in Ho

    Indian Academy of Sciences (India)

    model [9], promptly emitted particles (PEPs) model [10], exciton model [11], etc. During the past decade a large number of reports have appeared [12–14] showing the occurrence of incomplete fusion at beam energy just above the Coulomb barrier. Recoil range distribution (RRD) measurements are particularly attractive for ...

  6. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  7. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  9. Estimation from incomplete multinomial data. Ph.D. Thesis - Harvard Univ.

    Science.gov (United States)

    Credeur, K. R.

    1978-01-01

    The vector of multinomial cell probabilities was estimated from incomplete data, incomplete in that it contains partially classified observations. Each such partially classified observation was observed to fall in one of two or more selected categories but was not classified further into a single category. The data were assumed to be incomplete at random. The estimation criterion was minimization of risk for quadratic loss. The estimators were the classical maximum likelihood estimate, the Bayesian posterior mode, and the posterior mean. An approximation was developed for the posterior mean. The Dirichlet, the conjugate prior for the multinomial distribution, was assumed for the prior distribution.

  10. Incomplete inversion of the hippocampus - a common developmental anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Bajic, Dragan; Wang, Chen; Raininko, Raili [Uppsala University Hospital, Department of Radiology, Uppsala (Sweden); Kumlien, Eva; Mattsson, Peter [Uppsala University Hospital, Department of Neurology, Uppsala (Sweden); Lundberg, Staffan; Eeg-Olofsson, Orvar [Uppsala University Hospital, Department of Child Neurology, Uppsala (Sweden)

    2008-01-15

    Incomplete inversion of the hippocampus, an imperfect fetal development, has been described in patients with epilepsy or severe midline malformations. We studied this condition in a nonepileptic population without obvious developmental anomalies. We analyzed the coronal MR images of 50 women and 50 men who did not have epilepsy. Twenty of them were healthy volunteers and 80 were patients without obvious intracranial developmental anomalies, intracranial masses, hydrocephalus or any condition affecting the temporal lobes. If the entire hippocampus (the head could not be evaluated) were affected, the incomplete inversion was classified as total, otherwise as partial. Incomplete inversion of the hippocampus was found in 19/100 subjects (9 women, 10 men). It was unilateral, always on the left side, in 13 subjects (4 women, 9 men): 9 were of the total type, 4 were partial. It was bilateral in six subjects (five women, one man): four subjects had total types bilaterally, two had a combination of total and partial types. The collateral sulcus was vertically oriented in all subjects with a deviating hippocampal shape. We conclude that incomplete inversion of the hippocampus is not an unusual morphologic variety in a nonepileptic population without other obvious intracranial developmental anomalies. (orig.)

  11. Medium-high frequency ultrasound and ozone based advanced oxidation for amoxicillin removal in water.

    Science.gov (United States)

    Kıdak, Rana; Doğan, Şifa

    2018-01-01

    In this study, treatment of an antibiotic compound amoxicillin by medium-high frequency ultrasonic irradiation and/or ozonation has been studied. Ultrasonic irradiation process was carried out in a batch reactor for aqueous amoxicillin solutions at three different frequencies (575, 861 and 1141kHz). The applied ultrasonic power was 75W and the diffused power was calculated as 14.6W/L. The highest removal was achieved at 575kHz ultrasonic frequency (>99%) with the highest pseudo first order reaction rate constant 0.04min -1 at pH 10 but the mineralization achieved was around 10%. Presence of alkalinity and humic acid species had negative effect on the removal efficiency (50% decrease). To improve the poor outcomes, ozonation had been applied with or without ultrasound. Ozone removed the amoxicillin at a rate 50 times faster than ultrasound. Moreover, due to the synergistic effect, coupling of ozone and ultrasound gave rise to rate constant of 2.5min -1 (625 times higher than ultrasound). In the processes where ozone was used, humic acid did not show any significant effect because the rate constant was so high that ozone has easily overcome the scavenging effects of natural water constituents. Furthermore, the intermediate compounds, after the incomplete oxidation mechanisms, has been analyzed to reveal the possible degradation pathways of amoxicillin through ultrasonic irradiation and ozonation applications. The outcomes of the intermediate compounds experiments and the toxicity was investigated to give a clear explanation about the safety of the resulting solution. The relevance of all the results concluded that hybrid advanced oxidation system was the best option for amoxicillin removal. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Ultrasound contrast agents: an overview.

    Science.gov (United States)

    Cosgrove, David

    2006-12-01

    adequacy of the ablation which can be extended if needed; this is much more convenient and cost-saving than moving the patient to CT and perhaps needing an additional ablation session at a later date. Similar considerations suggest that contrast-enhanced ultrasound might have a role in abdominal trauma: injury to the liver, spleen and kidneys can be assessed rapidly and repeatedly if necessary. Its role here alongside dynamic CT remains to be evaluated. Infarcts or ischaemia and regions of abnormal vascularity, especially in malignancies, in the kidneys and spleen seem to be useful and improved detection of the neovascularisation of ovarian carcinomas is promising. Similar benefits in the head-and-neck and in the skin while the demonstration of the neovascularisation of atheromatous plaques and of aggressive joint inflammation offer interesting potentials.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are ...

  14. Kurt Gödel, completeness, incompleteness

    Czech Academy of Sciences Publication Activity Database

    Hájek, Petr

    2007-01-01

    Roč. 82, č. 1 (2007), 012005_1-012005_4 E-ISSN 1742-6596. [Brno Kurt Gödel Days. Brno, 25.04.2007-28.04.2007] R&D Projects: GA AV ČR IAA100300503 Institutional research plan: CEZ:AV0Z10300504 Keywords : Kurt Gödel * completeness * incompleteness Subject RIV: BA - General Mathematics

  15. Theorems of Tarski's Undefinability and Godel's Second Incompleteness - Computationally

    OpenAIRE

    Salehi, Saeed

    2015-01-01

    We present a version of Godel's Second Incompleteness Theorem for recursively enumerable consistent extensions of a fixed axiomatizable theory, by incorporating some bi-theoretic version of the derivability conditions (first discussed by M. Detlefsen 2001). We also argue that Tarski's theorem on the Undefinability of Truth is Godel's First Incompleteness Theorem relativized to definable oracles; here a unification of these two theorems is given.

  16. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound

    DEFF Research Database (Denmark)

    Ghulam, Q. M.; Bredahl, K. K.; Lönn, L.

    2017-01-01

    Objectives Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared...... with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. Design This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. Material and methods In total, 179 patients with small infrarenal AAAs (diameter 30–55 mm) were enrolled......L) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. Conclusion In this cohort of small AAAs, 40% of patients with a stable...

  17. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  18. Xanthogranulomatous Pyelonephritis with Incomplete Double Ureter

    Directory of Open Access Journals (Sweden)

    Yutaro Hayashi

    2017-01-01

    Full Text Available Introduction. Xanthogranulomatous pyelonephritis (XGP is a type of chronic renal inflammation that usually occurs in immunocompromised middle-aged women with chronic urinary tract infection or ureteral obstruction induced by the formation of ureteral stones. XGP with an incomplete double ureter is extremely rare. Case Presentation. A 76-year-old woman was referred to our department to undergo further examination for a left renal tumor that was detected by ultrasonography. Dynamic contrast computed tomography (CT revealed an enhanced tumor in the upper renal parenchyma. Laparoscopic radical nephrectomy was performed based on a preoperative diagnosis of renal cell carcinoma. Histological sections showed the aggregation of foam cells; thus, XGP was diagnosed. Conclusion. We herein report a rare case of XGP in the upper pole of the kidney, which might have been associated with an incomplete double ureter.

  19. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  20. Localization of liver tumors in freehand 3D laparoscopic ultrasound

    Science.gov (United States)

    Shahin, O.; Martens, V.; Besirevic, A.; Kleemann, M.; Schlaefer, A.

    2012-02-01

    The aim of minimally invasive laparoscopic liver interventions is to completely resect or ablate tumors while minimizing the trauma caused by the operation. However, restrictions such as limited field of view and reduced depth perception can hinder the surgeon's capabilities to precisely localize the tumor. Typically, preoperative data is acquired to find the tumor(s) and plan the surgery. Nevertheless, determining the precise position of the tumor is required, not only before but also during the operation. The standard use of ultrasound in hepatic surgery is to explore the liver and identify tumors. Meanwhile, the surgeon mentally builds a 3D context to localize tumors. This work aims to upgrade the use of ultrasound in laparoscopic liver surgery. We propose an approach to segment and localize tumors intra-operatively in 3D ultrasound. We reconstruct a 3D laparoscopic ultrasound volume containing a tumor. The 3D image is then preprocessed and semi-automatically segmented using a level set algorithm. During the surgery, for each subsequent reconstructed volume, a fast update of the tumor position is accomplished via registration using the previously segmented and localized tumor as a prior knowledge. The approach was tested on a liver phantom with artificial tumors. The tumors were localized in approximately two seconds with a mean error of less than 0.5 mm. The strengths of this technique are that it can be performed intra-operatively, it helps the surgeon to accurately determine the location, shape and volume of the tumor, and it is repeatable throughout the operation.

  1. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  2. Improved Balanced Incomplete Factorization

    Czech Academy of Sciences Publication Activity Database

    Bru, R.; Marín, J.; Mas, J.; Tůma, Miroslav

    2010-01-01

    Roč. 31, č. 5 (2010), s. 2431-2452 ISSN 0895-4798 R&D Projects: GA AV ČR IAA100300802 Grant - others:GA AV ČR(CZ) M100300902 Institutional research plan: CEZ:AV0Z10300504 Source of funding: I - inštitucionálna podpora na rozvoj VO Keywords : preconditioned iterative methods * sparse matrices * incomplete decompositions * approximate inverses * Sherman-Morrison formula * nonsymmetric matrices Subject RIV: BA - General Mathematics Impact factor: 1.725, year: 2010

  3. Production in Incomplete Markets

    DEFF Research Database (Denmark)

    Crès, Hervé; Tvede, Mich

    Abstract In the present paper we study voting-based corporate control in a general equilibrium model with incomplete financial markets. Since voting takes place in a multi-dimensional setting, super-majority rules are needed to ensure existence of equilibrium. In a linear-quadratic setup we show ...... that the endogenization of voting weights (given by portfolio holdings) can give rise to - through selffulfilling expectations - dramatical political instability, i.e. Condorcet cycles of length two even for very high majority rules....

  4. Color optimization of conjugated-polymer/InGaN hybrid white light emitting diodes by incomplete energy transfer

    International Nuclear Information System (INIS)

    Chang, Chi-Jung; Lai, Chun-Feng; Madhusudhana Reddy, P.; Chen, Yung-Lin; Chiou, Wei-Yung; Chang, Shinn-Jen

    2015-01-01

    By using the wavelength conversion method, white light emitting diodes (WLEDs) were produced by applying mixtures of polysiloxane and fluorescent polymers on InGaN based light emitting diodes. UV curable organic–inorganic hybrid materials with high refractive index (1.561), compromised optical, thermal and mechanical properties was used as encapsulants. Red light emitting fluorescent FABD polymer (with 9,9-dioctylfluorene (F), anthracene (A) and 2,1,3-benzothiadiazole (B), and 4,7-bis(2-thienyl)-2,1,3-benzothiadiazole (D) repeating units) and green light emitting fluorescent FAB polymer were used as wavelength converters. The encapsulant/fluorescent polymer mixture and InGaN produce the white light by incomplete energy transfer mechanism. WLEDs with high color rendering index (CRI, about 93), and tunable correlated color temperature (CCT) properties can be produced by controlling the composition and chemical structures of encapsulating polymer and fluorescent polymer in hybrid materials, offering cool-white and neutral-white LEDs. - Highlights: • Highly efficient white light-emitting diodes (WLEDs) were produced. • Conjugated-polymer/InGaN hybrid WLEDs by incomplete energy transfer mechanism. • WLEDs with high color-rendering index and tunable correlated color temperature. • Polysiloxane encapsulant with superior optical, mechanical and thermal properties

  5. Physically sound parameterization of incomplete ionization in aluminum-doped silicon

    Directory of Open Access Journals (Sweden)

    Heiko Steinkemper

    2016-12-01

    Full Text Available Incomplete ionization is an important issue when modeling silicon devices featuring aluminum-doped p+ (Al-p+ regions. Aluminum has a rather deep state in the band gap compared to boron or phosphorus, causing strong incomplete ionization. In this paper, we considerably improve our recent parameterization [Steinkemper et al., J. Appl. Phys. 117, 074504 (2015]. On the one hand, we found a fundamental criterion to further reduce the number of free parameters in our fitting procedure. And on the other hand, we address a mistake in the original publication of the incomplete ionization formalism in Altermatt et al., J. Appl. Phys. 100, 113715 (2006.

  6. Scintigraphic detection of 'yo-yo' phenomenon in incomplete ureteric duplication

    International Nuclear Information System (INIS)

    Chu, Winnie C.W.; Chan, Kam-wing; Metreweli, Constantine

    2003-01-01

    'Yo-yo' reflux in an incompletely duplicated renal system was demonstrated on 99m Tc-mercaptoacetyltriglycine (MAG3) renal scintigraphy in a 7-year-old girl presenting with low-grade fever and pyelonephritis. Incomplete duplication and a bifid renal pelvis, which may be seen in up to 4% of the North American population, occasionally causes symptoms because of recurrent urinary tract infection or loin pain. 99m Tc-MAG3 renal scintigraphy can demonstrate 'yo-yo' reflux in patients with incomplete renal duplication and should be considered in cases with unexplained loin pain, even if 99m Tc-dimercaptosuccinic acid (DMSA) renal scintigraphy is normal. (orig.)

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  8. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  9. Advanced incomplete factorization algorithms for Stiltijes matrices

    Energy Technology Data Exchange (ETDEWEB)

    Il`in, V.P. [Siberian Division RAS, Novosibirsk (Russian Federation)

    1996-12-31

    The modern numerical methods for solving the linear algebraic systems Au = f with high order sparse matrices A, which arise in grid approximations of multidimensional boundary value problems, are based mainly on accelerated iterative processes with easily invertible preconditioning matrices presented in the form of approximate (incomplete) factorization of the original matrix A. We consider some recent algorithmic approaches, theoretical foundations, experimental data and open questions for incomplete factorization of Stiltijes matrices which are {open_quotes}the best{close_quotes} ones in the sense that they have the most advanced results. Special attention is given to solving the elliptic differential equations with strongly variable coefficients, singular perturbated diffusion-convection and parabolic equations.

  10. Repetibilidade da mensuração de imagens das características de carcaça obtidas por ultrassonografia em fêmeas Nelore Repeatability of ultrasound image measurements of carcass traits in Nellore cattle

    Directory of Open Access Journals (Sweden)

    Maria Eugênia Zerlotti Mercadante

    2010-04-01

    Full Text Available Avaliou-se a repetibilidade da mensuração de imagens de ultrassom da área do músculo longissimus dorsi (AOL e das espessuras de gordura subcutânea do lombo (EGL e da garupa (EGG. Imagens de ultrassom tomadas no lombo (entre a 12ª e a 13ª costela e na garupa (entre os músculos gluteus medium e biceps femoris de novilhas Nelore de 14 a 22 meses de idade foram classificadas em aceitáveis, marginais e rejeitáveis. As imagens aceitáveis e marginais foram mensuradas duas vezes por três técnicos em diferentes níveis de treinamento. Foram estimadas as repetibilidades entre e dentro de técnicos por classe de qualidade da imagem, para determinação do efeito da qualidade da imagem e do técnico no valor absoluto da diferença entre a primeira e a segunda mensuração dessas características. A repetibilidade para as imagens aceitáveis foi maior que para imagens marginais, tanto entre como dentro de técnicos. Na análise da diferença absoluta entre a primeira e a segunda interpretação, foram significativos os efeitos de técnico para AOL e EGL e de classe de qualidade da imagem para AOL. Em geral, o técnico com maior experiência apresentou maiores valores de repetibilidade. É recomendável que a mensuração de imagens de animais de mesmo grupo contemporâneo seja feita por um único técnico.The repeatability of ultrasound image measurements of the longissimus dorsi muscle (AOL and of the rumpfat (EGG and backfat (EGL subcutaneous thickness was evaluated. Ultrasound images taken from the back (between 12th and 13th ribs and from the rump (between gluteus medium and biceps femoris muscles of Nelore heifers at 14 and 22 months of age were classified as acceptable, marginal and rejected. The acceptable and marginal images were measured twice by three technicians at different levels of training. It was estimated repeatabilities among and within technicians by class of image quality in order to determine effect of image quality and of

  11. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  12. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  13. Ultrasound contrast agents: An overview

    International Nuclear Information System (INIS)

    Cosgrove, David

    2006-01-01

    vasospasm after subarachnoid haemorrhage). An important situation where demonstrating tissue devitalisation is important is in interstitial ablation of focal liver lesions: using microbubble contrast agents at the end of a procedure allows immediate evaluation of the adequacy of the ablation which can be extended if needed; this is much more convenient and cost-saving than moving the patient to CT and perhaps needing an additional ablation session at a later date. Similar considerations suggest that contrast-enhanced ultrasound might have a role in abdominal trauma: injury to the liver, spleen and kidneys can be assessed rapidly and repeatedly if necessary. Its role here alongside dynamic CT remains to be evaluated. Infarcts or ischaemia and regions of abnormal vascularity, especially in malignancies, in the kidneys and spleen seem to be useful and improved detection of the neovascularisation of ovarian carcinomas is promising. Similar benefits in the head-and-neck and in the skin while the demonstration of the neovascularisation of atheromatous plaques and of aggressive joint inflammation offer interesting potentials

  14. Spectral analysis of parallel incomplete factorizations with implicit pseudo­-overlap

    NARCIS (Netherlands)

    Magolu monga Made, Mardochée; Vorst, H.A. van der

    2000-01-01

    Two general parallel incomplete factorization strategies are investigated. The techniques may be interpreted as generalized domain decomposition methods. In contrast to classical domain decomposition methods, adjacent subdomains exchange data during the construction of the incomplete

  15. Endovascular ultrasound for renal sympathetic denervation in patients with therapy-resistant hypertension not responding to radiofrequency renal sympathetic denervation.

    Science.gov (United States)

    Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp

    2016-06-12

    Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (pmeasures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  18. Production in incomplete markets

    DEFF Research Database (Denmark)

    Crès, Hervé; Tvede, Mich

    2009-01-01

    In the present paper we study voting-based corporate control in a general equilibrium model with incomplete financial markets. Since voting takes place in a multi-dimensional setting, super-majority rules are needed to ensure existence of equilibrium. In a linear-quadratic setup we show that the ...... that the endogenization of voting weights (given by portfolio holdings) can give rise to - through self-fulfilling expectations - dramatical political instability, i.e. Condorcet cycles of length two even for very high majority rules....

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  6. RELIABILITY MODELING BASED ON INCOMPLETE DATA: OIL PUMP APPLICATION

    Directory of Open Access Journals (Sweden)

    Ahmed HAFAIFA

    2014-07-01

    Full Text Available The reliability analysis for industrial maintenance is now increasingly demanded by the industrialists in the world. Indeed, the modern manufacturing facilities are equipped by data acquisition and monitoring system, these systems generates a large volume of data. These data can be used to infer future decisions affecting the health facilities. These data can be used to infer future decisions affecting the state of the exploited equipment. However, in most practical cases the data used in reliability modelling are incomplete or not reliable. In this context, to analyze the reliability of an oil pump, this work proposes to examine and treat the incomplete, incorrect or aberrant data to the reliability modeling of an oil pump. The objective of this paper is to propose a suitable methodology for replacing the incomplete data using a regression method.

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  10. Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.

    Science.gov (United States)

    Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L

    2018-06-01

    Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  16. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  17. In vivo demonstration of ultrasound power delivery to charge implanted medical devices via acute and survival porcine studies.

    Science.gov (United States)

    Radziemski, Leon; Makin, Inder Raj S

    2016-01-01

    Animal studies are an important step in proving the utility and safety of an ultrasound based implanted battery recharging system. To this end an Ultrasound Electrical Recharging System (USER™) was developed and tested. Experiments in vitro demonstrated power deliveries at the battery of up to 600 mW through 10-15 mm of tissue, 50 mW of power available at tissue depths of up to 50 mm, and the feasibility of using transducers bonded to titanium as used in medical implants. Acute in vivo studies in a porcine model were used to test reliability of power delivery, temperature excursions, and cooling techniques. The culminating five-week survival study involved repeated battery charging, a total of 10.5h of ultrasound exposure of the intervening living tissue, with an average RF input to electrical charging efficiency of 20%. This study was potentially the first long term cumulative living-tissue exposure using transcutaneous ultrasound power transmission to an implanted receiver in situ. Histology of the exposed tissue showed changes attributable primarily due to surgical implantation of the prototype device, and no damage due to the ultrasound exposure. The in vivo results are indicative of the potential safe delivery of ultrasound energy for a defined set of source conditions for charging batteries within implants. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  19. Decontamination of transvaginal ultrasound probes: Review of national practice and need for national guidelines

    International Nuclear Information System (INIS)

    Gray, R.A.; Williams, P.L.; Dubbins, P.A.; Jenks, P.J.

    2012-01-01

    Aim: To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. Materials and methods: A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. Results: There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. Conclusion: While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.

  20. Spatial and temporal profile of cisplatin delivery by ultrasound-assisted intravesical chemotherapy in a bladder cancer model.

    Directory of Open Access Journals (Sweden)

    Noboru Sasaki

    Full Text Available Non-muscle invasive bladder cancer is one of the most common tumors of the urinary tract. Despite the current multimodal therapy, recurrence and progression of disease have been challenging problems. We hereby introduced a new approach, ultrasound-assisted intravesical chemotherapy, intravesical instillation of chemotherapeutic agents and microbubbles followed by ultrasound exposure. We investigated the feasibility of the treatment for non-muscle invasive bladder cancer. In order to evaluate intracellular delivery and cytotoxic effect as a function to the thickness, we performed all experiments using a bladder cancer mimicking 3D culture model. Ultrasound-triggered microbubble cavitation increased both the intracellular platinum concentration and the cytotoxic effect of cisplatin at the thickness of 70 and 122 μm of the culture model. The duration of enhanced cytotoxic effect of cisplatin by ultrasound-triggered microbubble cavitation was approximately 1 hr. Based on the distance and duration of delivery, we further tested the feasibility of repetition of the treatment. Triple treatment increased the effective distance by 1.6-fold. Our results clearly showed spatial and temporal profile of delivery by ultrasound-triggered microbubble cavitation in a tumor-mimicking structure. Furthermore, we demonstrated that the increase in intracellular concentration results in the enhancement of the cytotoxic effect in a structure with the certain thickness. Repetition of ultrasound exposure would be treatment of choice in future clinical application. Our results suggest ultrasound-triggered microbubble cavitation can be repeatable and is promising for the local control of non-muscle invasive bladder cancer.

  1. Preliminary studies on premature rickets of infants by high-frequency probe ultrasound

    International Nuclear Information System (INIS)

    Yu Ming'an; Xu Zushan; Tang Zhongjuan; Song Jing; Liu Jie; Li Qiang; Gong Huafang; Bi Haijing

    2002-01-01

    Objective: To observe the ultrasound appearance of premature rickets in infants, and to assess the diagnostic value of high-frequency probe in the disease. Methods:Ultrasonography was performed in R-No 4 rib and distal radioulnar metaphysis in 123 rickets infants diagnosed by clinical examination (the diagnosis standard adopted the rickets diagnose standard revised by the rickets research, prevention and cure group of China in 1999)and in 30 normal infants diagnosed by clinical examination as the control group. Results: The high-frequency probe could clearly visualize the modification of every part in ribs and distal radioulnar metaphysis. Compared with that of the normal control group, ultrasound showed individually the signs and symptoms such as separation, bone bark elongation, and bone bark warp in the engagement of periosteum and perichondrium in rickets group. The incidences of bone bark elongation were separately 18.7% (23 cases) in ulna, 10.6% (13 cases) in radius, and 41.5% (51 cases) in rib; The incidences of bone bark warp were separately 4.9% (6 cases) in ulna, 2.4% (3 cases) in radius, and 18.7% (23 cases) in rib. The results of chi-square test showed that both the incidences of bone bark elongation and bone bark warp between the rib and the ulna and radius had significant difference (P < 0.01). The incidences of incomplete calcification in the edge of the provisional calcification zone were 96.75% (119 cases) in ulna and 69.29% (84 cases) in radius, respectively (Ridit test, P < 0.01). The incidences of incomplete calcification inside the provisional calcification zone were 42.28% (52 cases) in ulna and 60.16% (74 cases) in radius, respectively (Radit test, P < 0.01). Conclusion: Study on every modification of premature rickets by high-frequency probe will help to determine the status and degree of calciprivia at earlier stages, and thereby to increase the specificity and sensitivity of ultrasonography

  2. About 'On certain incomplete statistics' by Lima et al

    International Nuclear Information System (INIS)

    Pezeril, M.; Le Mehaute, A.; Wang, Q.A.

    2004-01-01

    Lima et al. recently claim that (Chaos, Solitons and Fractals 19 (2004) 1005) the entropy for the incomplete statistics based on the normalization Σ i p i q =1 should be S=-Σ i p i 2q-1 ln q p i instead of S=-Σ i p i q ln q p i initially proposed by Wang. We indicate here that this conclusion is a result of erroneous use of temperature definition for the incomplete statistics

  3. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  5. Noninvasive pulsed focused ultrasound allows spatiotemporal control of targeted homing for multiple stem cell types in murine skeletal muscle and the magnitude of cell homing can be increased through repeated applications.

    Science.gov (United States)

    Burks, Scott R; Ziadloo, Ali; Kim, Saejeong J; Nguyen, Ben A; Frank, Joseph A

    2013-11-01

    Stem cells are promising therapeutics for cardiovascular diseases, and i.v. injection is the most desirable route of administration clinically. Subsequent homing of exogenous stem cells to pathological loci is frequently required for therapeutic efficacy and is mediated by chemoattractants (cell adhesion molecules, cytokines, and growth factors). Homing processes are inefficient and depend on short-lived pathological inflammation that limits the window of opportunity for cell injections. Noninvasive pulsed focused ultrasound (pFUS), which emphasizes mechanical ultrasound-tissue interactions, can be precisely targeted in the body and is a promising approach to target and maximize stem cell delivery by stimulating chemoattractant expression in pFUS-treated tissue prior to cell infusions. We demonstrate that pFUS is nondestructive to murine skeletal muscle tissue (no necrosis, hemorrhage, or muscle stem cell activation) and initiates a largely M2-type macrophage response. We also demonstrate that local upregulation of chemoattractants in pFUS-treated skeletal muscle leads to enhance homing, permeability, and retention of human mesenchymal stem cells (MSC) and human endothelial precursor cells (EPC). Furthermore, the magnitude of MSC or EPC homing was increased when pFUS treatments and cell infusions were repeated daily. This study demonstrates that pFUS defines transient "molecular zip codes" of elevated chemoattractants in targeted muscle tissue, which effectively provides spatiotemporal control and tunability of the homing process for multiple stem cell types. pFUS is a clinically translatable modality that may ultimately improve homing efficiency and flexibility of cell therapies for cardiovascular diseases. © AlphaMed Press.

  6. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Comparison of manual vacuum aspiration and misoprostol in the management of incomplete abortion

    Directory of Open Access Journals (Sweden)

    Gabkika Bray Madoue

    2016-11-01

    Full Text Available Background: Incomplete abortions can be managed expectantly, surgically and medically (using misoprostol. Expectant management is safe in places where women have access to information, appropriate care and follow-up; however, in isolated and poor areas women who come for help need an intervention. Objective: To compare the efficiency of manual vacuum aspiration (MVA and misoprostol in the treatment of incomplete abortion. Patients and method: This was a prospective study over five months from March to August 2015. All patients admitted with a diagnosis of incomplete abortion were recruited into the study. Results: 308 patients with incomplete abortion were randomized into two treatment groups - MVA (done under local anaesthesia and misoprostol (400 micrograms by the vaginal route. MVA was successfully performed for all patients. Two patients presented with anaemia. In the misoprostol group, 23 patients had vaginal bleeding, and 10 persistence of incomplete abortion. Conclusion: MVA is more effective than misoprostol with less complications in the treatment of incomplete abortion when it is done by a trained person.

  8. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  9. Migraine without aura is not associated with incomplete circle of Willis

    DEFF Research Database (Denmark)

    Ezzatian-Ahar, Shabnam; Amin, Faisal Mohammad; Obaid, Hayder Ghani

    2014-01-01

    the prevalence of incomplete circle of Willis in migraineurs and controls. In the present study we compared the prevalence of incomplete circle of Willis in female migraine patients without aura to female healthy non-migraine controls.Using 3-Tesla magnetic resonance angiography we recorded three...

  10. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  11. 32 CFR 651.44 - Incomplete information.

    Science.gov (United States)

    2010-07-01

    ... ENVIRONMENTAL ANALYSIS OF ARMY ACTIONS (AR 200-2) Environmental Impact Statement § 651.44 Incomplete information. When the proposed action will have significant adverse effects on the human environment, and there is... essential to a reasoned choice among alternatives and the overall costs of obtaining it are not exorbitant...

  12. Dose-response curves from incomplete data

    International Nuclear Information System (INIS)

    Groer, P.G.

    1978-01-01

    Frequently many different responses occur in populations (animal or human) exposed to ionizing radiation. To obtain a dose-response curve, the exposed population is first divided into sub-groups whose members received the same radiation dose. To estimate the response, the fraction of subjects in each sub-group that showed the particular response of interest is determined. These fractions are plotted against dose to give the dose-response curve. This procedure of plotting the fractions versus the radiation dose is not the correct way to estimate the time distribution for a particular response at the different dose levels. Other observed responses competed for the individuals in the exposed population and therefore prevented manifestation of the complete information on the response-time distribution for one specific response. Such data are called incomplete in the statistical literature. A procedure is described which uses the by now classical Kaplan-Meier estimator, to establish dose-response curves from incomplete data under the assumption that the different observed responses are statistically independent. It is demonstrated that there is insufficient information in the observed survival functions to estimate the time distribution for one particular response if the assumption of independence is dropped. In addition, it is not possible to determine from the data (i.e. type of response and when it occurred) whether or not the different response-time distributions are independent. However, it is possible to give sharp bounds between which the response has to lie. This implies that for incomplete data, only a 'dose-response band' can be established if independence of the competing responses cannot be assumed. Examples are given using actual data to illustrate the estimation procedures

  13. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  14. Incomplete-data image reconstructions in industrial x-ray computerized tomography

    International Nuclear Information System (INIS)

    Tam, K.C.; Eberhard, J.W.; Mitchell, K.W.

    1989-01-01

    In earlier works it was concluded that image reconstruction from incomplete data can be achieved through an iterative transform algorithm which utilizes the a priori information on the object to compensate for the missing data. The image is transformed back and forth between the object space and the projection space, being corrected by the a priori information on the object in the object space, and by the known projections in the projection space. The a priori information in the object space includes a boundary enclosing the object, and an upper bound and a lower bound of the object density. In this paper we report the results of testing the iterative transform algorithm on experimental data. X-ray sinogram data of the cross section of a F404 high-pressure turbine blade made of Ni-based superalloy were supplied to us by the Aircraft Engine Business Group of General Electric Company at Cincinnati, Ohio. From the data set we simulated two kinds of incomplete data situations, incomplete projection and limited-angle scanning, and applied the iterative transform algorithm to reconstruct the images. The results validated the practical value of the iterative transform algorithm in reconstructing images from incomplete x-ray data, both incomplete projections and limited-angle data. In all the cases tested there were significant improvements in the appearance of the images after iterations. The visual improvements are substantiated in a quantitative manner by the plots of errors in wall thickness measurements which in general decrease in magnitude with iterations

  15. Transition Complexity of Incomplete DFAs

    Directory of Open Access Journals (Sweden)

    Yuan Gao

    2010-08-01

    Full Text Available In this paper, we consider the transition complexity of regular languages based on the incomplete deterministic finite automata. A number of results on Boolean operations have been obtained. It is shown that the transition complexity results for union and complementation are very different from the state complexity results for the same operations. However, for intersection, the transition complexity result is similar to that of state complexity.

  16. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  18. Surveillance of Hemodialysis Vascular Access with Ultrasound Vector Flow Imaging

    DEFF Research Database (Denmark)

    Brandt, Andreas Hjelm; Olesen, Jacob Bjerring; Lindskov Hansen, Kristoffer

    2015-01-01

    -functioning vascular access with as few complications as possible and preferred vascular access is an AVF. Dysfunction due to stenosis is a common complication, and regular monitoring of volume flow is recommended to preserve AVF patency. UDT is considered the gold standard for volume flow surveillance, but VFI has...... proven to be more precise, when performing single repeated instantaneous measurements. Three patients with AVF were monitored with UDT and VFI monthly for five months. A commercial ultrasound scanner with a 9 MHz linear array transducer with integrated VFI was used to obtain data. UDT values were...... be used for surveillance of volume flow....

  19. Trans-abdominal ultrasound evaluation of high-intensity focused ultrasound treatment of uterine leiomyoma

    International Nuclear Information System (INIS)

    Miao Wei; Huang Jin; Wang Junhua; Wang Yuling

    2010-01-01

    Objective: To determine the value of dynamic trans-abdominal ultrasound after high-intensity focused ultrasound (HIFU) treatment of uterine leiomyomas. Methods: The trans-abdominal ultrasound images of 63 patients before and after HIFU treatment of uterine leiomyomas were compared. Results: The volume and blood flow of leiomyomas were reduced after the HIFU treatment. Conclusion: Trans-abdominal ultrasound is a valuable method for evaluating the results of HIFU treatment of uterine leiomyomas. (authors)

  20. Multiple high-intensity focused ultrasound probes for kidney-tissue ablation.

    Science.gov (United States)

    Häcker, Axel; Chauhan, Sunita; Peters, Kristina; Hildenbrand, Ralf; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan

    2005-10-01

    To investigate kidney-tissue ablation by high-intensity focused ultrasound (HIFU) using multiple and single probes. Ultrasound beams (1.75 MHz) produced by a piezoceramic element (focal distance 80 mm) were focused at the center of renal parenchyma. One of the three probes (mounted on a jig) could also be used for comparison with a single probe at comparable power ratings. Lesion dimensions were examined in perfused and unperfused ex vivo porcine kidneys at different power levels (40, 60, and 80 W) and treatment times (4, 6, and 8 seconds). At identical power levels, the lesions induced by multiple probes were larger than those induced by a single probe. Lesion size increased with increasing pulse duration and generator power. The sizes and shapes of the lesions were predictably repeatable in all samples. Lesions in perfused kidneys were smaller than those in unperfused kidneys. Ex vivo, kidney-tissue ablation by means of multiple HIFU probes offers significant advantages over single HIFU probes in respect of lesion size and formation. These advantages need to be confirmed by tests in vivo at higher energy levels.

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  2. Metatarsophalangeal joint extension changes ultrasound measurements for plantar fascia thickness.

    Science.gov (United States)

    Granado, Michael J; Lohman, Everett B; Gordon, Keith E; Daher, Noha S

    2018-01-01

    Ultrasound is an inexpensive method for quantifying plantar fascia thickness, especially in those with plantar fasciitis. Ultrasound has also been used to assess the effectiveness of various treatments for plantar fasciitis by comparing plantar fascia thickness before and after an intervention period. While a plantar fascia thickness over 4 mm via ultrasound has been proposed to be consistent with plantar fasciitis, some researchers believe the 4 mm plantar fascia thickness level to be a dubious guideline for diagnosing plantar fasciitis due to the lack of standardization of the measurement process for plantar fascia thickness. In particular, no universal guidelines exist on the positioning of the metatarsophalangeal (MTP) joints during the procedure and the literature also has inconsistent protocols. The purpose of this study is to investigate and compare the influence of MTP joint extension on plantar fascia thickness in healthy participants and those with unilateral plantar fasciitis. The plantar fascia thickness of forty participants (20 with unilateral plantar fasciitis and 20 control) was measured via ultrasound three times at three different MTP joint positions: 1) at rest, 2) 30° of extension from the plantar surface, and 3) maximal extension possible. The plantar fascia became significantly thinner as MTP joint extension increased in both the plantar fasciitis group ( p  plantar fasciitis group, the involved plantar fascia was 1.2 to 1.3 mm thicker (p plantar fascia thickness between the two sides was less than 0.1 mm ( p  plantar fascia thickness. It is recommended that plantar fascia thickness measurements be performed with the toes at rest. If MTP joints must be extended, then the toes should be extended maximally and then noted to ensure subsequent ultrasound procedures are repeated. Standardizing the position of the MTP joints is not only important for attaining the most accurate thickness measurement of the plantar fascia, but is also

  3. Research on defect detection from incomplete scanning of X-ray

    International Nuclear Information System (INIS)

    Zhang Shunli; Zhang Dinghua; Cheng Yunyong; Li Xiaolin

    2011-01-01

    Computed tomography (CT) is an advanced means of non-destructive testing, which has been widely used in medical and industrial fields. Aiming at the non-destructive testing problem of large industrial components, It presents a defect detection method from incomplete scanning of X-ray. Firstly, a set of incomplete scanning projection data before using the component has been obtained, then reconstruct them by algebraic re- construction technique (ART), and take the reconstructed images as the norm images. Then, the incomplete projection data of different times during the use of the component has been obtained, and reconstruct them by ART algorithm. Finally, It makes digital subtraction operation by the reconstructed images and the norm images, the defection can be detected clearly and intuitively from the subtraction image. Experimental result shows the proposed method is effective. (authors)

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  5. Multicenter assessment of venous reflux by duplex ultrasound.

    Science.gov (United States)

    Lurie, Fedor; Comerota, Anthony; Eklof, Bo; Kistner, Robert L; Labropoulos, Nicos; Lohr, Joann; Marston, William; Meissner, Mark; Moneta, Gregory; Neglén, Peter; Neuhardt, Diana; Padberg, Frank; Welsh, Harold J

    2012-02-01

    This prospective multicenter investigation was conducted to define the repeatability of duplex-based identification of venous reflux and the relative effect of key parameters on the reproducibility of the test. Repeatability was studied by having the same technologist perform duplicate tests, at the same time of the day, using the same reflux-provoking maneuver and with the patient in the same position. Reproducibility was examined by having two different technologists perform the test at the same time of the day, using the same reflux-provoking maneuver and with the patient in the same position. Facilitated reproducibility was studied by having two different technologists examine the same patients immediately after an educational intervention. Limits of agreement between two duplex scans were studied by changing three elements of the test: time of the day (morning vs afternoon), patient's position (standing vs supine), and reflux initiation (manual vs automatic compression-decompression). The study enrolled 17 healthy volunteers and 57 patients with primary chronic venous disease. Repeatability of reflux time measurements in deep veins did not significantly differ with the time of day, the patient's position, or the reflux-provoking maneuver. Reflux measurements in the superficial veins were more repeatable (P ultrasound detection of venous reflux. Reports should include information on the time of the test, the patient's position, and the provoking maneuver used. Adopting a uniform cut point of 0.5 second for pathologic reflux can significantly improve the reliability of reflux detection. Implementation of a standard protocol should elevate the minimal standard for agreement between repeated tests from the current 70% to at least 80% and with more rigid standardization, to 90%. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  6. The Indian ultrasound paradox

    OpenAIRE

    Akbulut-Yuksel, Mevlude; Rosenblum, Daniel

    2012-01-01

    The liberalization of the Indian economy in the 1990s made prenatal ultrasound technology affordable and available to a large fraction of the population. As a result, ultrasound use amongst pregnant women rose dramatically in many parts of India. This paper provides evidence on the consequences of the expansion of prenatal ultrasound use on sex-selection. We exploit state-by-cohort variation in ultrasound use in India as a unique quasi-experiment. We find that sex-selective abortion of female...

  7. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training....

  8. Incomplete albinism in Discoglossus pictus (Otth, 1837

    Directory of Open Access Journals (Sweden)

    Filippo Spadola

    2010-12-01

    Full Text Available The authors present an incomplete albinism case in a Discoglossus pictus subject found in Sicily. This is the first note for Italian territory, the second for the species and the third for Discoglossus genus.

  9. Effects of using simulation versus CD-ROM in the performance of ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Gasko, John; Johnson, Arthur; Sherner, John; Craig, John; Gegel, Brian; Burgert, James; Sama, Samuel; Franzen, Thomas

    2012-08-01

    The purpose of this study was to determine which method of teaching, CD-ROM, simulation, or a combination of both, was more effective in increasing the performance of ultrasound-guided regional anesthesia. No studies have investigated these methods. The framework for this study was critical thinking. The study was a prospective, mixed (between and within) subjects, experimental design. The sample consisted of 29 student registered nurse anesthetists randomly assigned to 1 of 3 groups: CD-ROM (n = 11), simulation (n = 11), and combination (n = 7). All groups were evaluated by the use of cadavers before and 2 months after the intervention using a valid and reliable instrument of performance. A repeated-measures analysis of variance indicated that the combination was significantly better than the CD-ROM and simulation (P teaching ultrasound-guided regional anesthesia techniques.

  10. [Ultrasound findings in rhabdomyolysis].

    Science.gov (United States)

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  11. Incomplete augmented Lagrangian preconditioner for steady incompressible Navier-Stokes equations.

    Science.gov (United States)

    Tan, Ning-Bo; Huang, Ting-Zhu; Hu, Ze-Jun

    2013-01-01

    An incomplete augmented Lagrangian preconditioner, for the steady incompressible Navier-Stokes equations discretized by stable finite elements, is proposed. The eigenvalues of the preconditioned matrix are analyzed. Numerical experiments show that the incomplete augmented Lagrangian-based preconditioner proposed is very robust and performs quite well by the Picard linearization or the Newton linearization over a wide range of values of the viscosity on both uniform and stretched grids.

  12. Physiological Motion and Registration of Abnormalities in Liver During Focused Ultrasound Surgery

    Science.gov (United States)

    Chauhan, Sunita; Rh, Abhilash

    Continuous deformation and dislocation of soft tissues in the abdominal and thoracic region presents a major issue for effective targeting of all non-invasive ablative modalities such as radiotherapy/surgery and Focused Ultrasound Surgery. Most significant among these is the movement of the target organs due to physiological processes such as respiration. The movement is found to be most significant for liver and kidneys. We studied movement and compensation strategies with the aim to implement them during ultrasound ablation using our robotic system for targeted FUS dose delivery. The motion pattern of the liver can be assumed to be in a single plane as it closely follows the movement of the diaphragm. However, the movement of kidneys is three dimensional and follows complicated patterns. Kidney motion is highly subject specific and has poor repeatability. In our research, we quantify the relation of liver movement and the breathing pattern so as to achieve real-time movement compensation using a prediction-correlation approach.

  13. Incompleteness in the finite domain

    Czech Academy of Sciences Publication Activity Database

    Pudlák, Pavel

    2017-01-01

    Roč. 23, č. 4 (2017), s. 405-441 ISSN 1079-8986 EU Projects: European Commission(XE) 339691 - FEALORA Institutional support: RVO:67985840 Keywords : finite domain Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.742, year: 2016 https://www.cambridge.org/core/journals/bulletin-of-symbolic-logic/article/incompleteness-in-the-finite-domain/D239B1761A73DCA534A4805A76D81C76

  14. Medical Ultrasound Imaging.

    Science.gov (United States)

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  15. Optimization of two methods based on ultrasound energy as alternative to European standards for soluble salts extraction from building materials.

    Science.gov (United States)

    Prieto-Taboada, N; Gómez-Laserna, O; Martinez-Arkarazo, I; Olazabal, M A; Madariaga, J M

    2012-11-01

    The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  17. Statistical evaluations of current sampling procedures and incomplete core recovery

    International Nuclear Information System (INIS)

    Heasler, P.G.; Jensen, L.

    1994-03-01

    This document develops two formulas that describe the effects of incomplete recovery on core sampling results for the Hanford waste tanks. The formulas evaluate incomplete core recovery from a worst-case (i.e.,biased) and best-case (i.e., unbiased) perspective. A core sampler is unbiased if the sample material recovered is a random sample of the material in the tank, while any sampler that preferentially recovers a particular type of waste over others is a biased sampler. There is strong evidence to indicate that the push-mode sampler presently used at the Hanford site is a biased one. The formulas presented here show the effects of incomplete core recovery on the accuracy of composition measurements, as functions of the vertical variability in the waste. These equations are evaluated using vertical variability estimates from previously sampled tanks (B110, U110, C109). Assuming that the values of vertical variability used in this study adequately describes the Hanford tank farm, one can use the formulas to compute the effect of incomplete recovery on the accuracy of an average constituent estimate. To determine acceptable recovery limits, we have assumed that the relative error of such an estimate should be no more than 20%

  18. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... used to screen for brain conditions associated with prematurity, such as bleeding or brain tissue damage as ... or crying child will slow the examination process. Large patients are more difficult to image by ultrasound, ...

  19. The effect of carbon dioxide on the twinkling artifact in ultrasound imaging of kidney stones: A pilot study

    Science.gov (United States)

    Simon, Julianna C.; Wang, Yak-Nam; Cunitz, Bryan W.; Thiel, Jeffrey; Starr, Frank; Liu, Ziyue; Bailey, Michael R.

    2016-01-01

    Bone demineralization, dehydration, and stasis put astronauts at an increased risk of forming kidney stones in space. The color-Doppler ultrasound “twinkling artifact”, which highlights kidney stones with color, can make stones readily detectable with ultrasound; however our previous results suggest twinkling is caused by microbubbles on the stone surface which could be affected by the elevated levels of carbon dioxide found on space vehicles. Four pigs were implanted with kidney stones and imaged with ultrasound while the anesthetic carrier gas oscillated between oxygen and air containing 0.8% carbon dioxide. Upon exposing pigs to 0.8% carbon dioxide, twinkling was significantly reduced after 9–25 minutes and recovered when the carrier gas returned to oxygen. These trends repeated when pigs were again exposed to 0.8% carbon dioxide followed by oxygen. The reduction of twinkling from exposure to elevated carbon dioxide may make kidney stone detection with twinkling difficult in current space vehicles. PMID:28190622

  20. Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube.

    Science.gov (United States)

    Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei

    2018-03-01

    This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs).A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis.When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P auscultation (67.4% [52.0%, 80.5%]) (P auscultation (54.4% [40.7%, 67.6%]) (P auscultation (47.8% [32.9%, 63.1%]) (P auscultation in determining the position of DLTs.

  1. Fault Diagnosis in Condition of Sample Type Incompleteness Using Support Vector Data Description

    Directory of Open Access Journals (Sweden)

    Hui Yi

    2015-01-01

    Full Text Available Faulty samples are much harder to acquire than normal samples, especially in complicated systems. This leads to incompleteness for training sample types and furthermore a decrease of diagnostic accuracy. In this paper, the relationship between sample-type incompleteness and the classifier-based diagnostic accuracy is discussed first. Then, a support vector data description-based approach, which has taken the effects of sample-type incompleteness into consideration, is proposed to refine the construction of fault regions and increase the diagnostic accuracy for the condition of incomplete sample types. The effectiveness of the proposed method was validated on both a Gaussian distributed dataset and a practical dataset. Satisfactory results have been obtained.

  2. Does Ultrasound-Enhanced Instruction of Musculoskeletal Anatomy Improve Physical Examination Skills of First-Year Medical Students?

    Science.gov (United States)

    Walrod, Bryant J; Schroeder, Allison; Conroy, Mark J; Boucher, Laura C; Bockbrader, Marcia; Way, David P; McCamey, Kendra L; Hartz, Clinton A; Jonesco, Michael A; Bahner, David P

    2018-01-01

    Ultrasound imaging is commonly used to teach basic anatomy to medical students. The purpose of this study was to determine whether learning musculoskeletal anatomy with ultrasound improved performance on medical students' musculoskeletal physical examination skills. Twenty-seven first-year medical students were randomly assigned to 1 of 2 instructional groups: either shoulder or knee. Both groups received a lecture followed by hands-on ultrasound scanning on live human models of the assigned joint. After instruction, students were assessed on their ability to accurately palpate 4 anatomic landmarks: the acromioclavicular joint, the proximal long-head biceps tendon, and the medial and lateral joint lines of the knee. Performance scores were based on both accuracy and time. A total physical examination performance score was derived for each joint. Scores for instructional groups were compared by a 2-way analysis of variance with 1 repeated measure. Significant findings were further analyzed with post hoc tests. All students performed significantly better on the knee examination, irrespective of instructional group (F = 14.9; df = 1.25; P = .001). Moreover, the shoulder instruction group performed significantly better than the knee group on the overall assessment (t = -3.0; df = 25; P soft tissue landmark. Both groups performed similarly on palpation of all other anatomic structures. The use of ultrasound appears to provide an educational advantage when learning musculoskeletal physical examination of soft tissue landmarks. © 2017 by the American Institute of Ultrasound in Medicine.

  3. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  4. Quantitative Ultrasound Measurements at the Heel

    DEFF Research Database (Denmark)

    Daugschies, M.; Brixen, K.; Hermann, P.

    2015-01-01

    Calcaneal quantitative ultrasound can be used to predict osteoporotic fracture risk, but its ability to monitor therapy is unclear possibly because of its limited precision. We developed a quantitative ultrasound device (foot ultrasound scanner) that measures the speed of sound at the heel...... with the foot ultrasound scanner reduced precision errors by half (p quantitative ultrasound measurements is feasible. (E-mail: m.daugschies@rad.uni-kiel.de) (C) 2015 World Federation for Ultrasound in Medicine & Biology....

  5. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Enhancement or Reduction of Sonochemical Activity of Pulsed Ultrasound Compared to Continuous Ultrasound at 20 kHz?

    Directory of Open Access Journals (Sweden)

    Yujing Sun

    2013-04-01

    Full Text Available Little is known about the efficacy of pulsed ultrasound compared with continuous ultrasound. Previous studies on the efficacy of pulsed ultrasound were not systematic and gave different results. In this study, the effects of pulse length, pulse interval, pulse length × pulse intervals, and treatment time on sonochemical activity were investigated using a simple oxidation of iodide method and a comparison of the efficacy of pulsed ultrasound and continuous ultrasound is made. The results showed that the main factor in the efficacy of pulsed ultrasound was pulse length when pulse length varied from 0.1 to 1 s. However, the main factors were pulse length, the pulse length × pulse interval, and pulse interval when pulse length varied from 1 to 9 s. Pulsed ultrasound had no effect when the pulse length was 0.1 s; however, the sonochemical activity of pulsed ultrasound decreased compared to continuous ultrasound as the pulse length varied from 0.1 to 1 s. The sonochemical activity of pulsed ultrasound either increased or decreased compared to continuous ultrasound when pulse length varied from 1 to 9 s, but the increase or decrease had no clear trend. The sonochemical activity was constant at Ton/Toff = 2 s/2 s and slightly decreased at Ton/Toff = 3 s/2 s with time, whereas the sonochemical activity of continuous ultrasound significantly decreased with time. Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound depended on the pulse length and pulse interval.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may produce minimal discomfort. If a Doppler ultrasound study is performed, you may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Most ultrasound examinations ...

  9. Subglottal pressure, tracheal airflow, and intrinsic laryngeal muscle activity during rat ultrasound vocalization

    Science.gov (United States)

    2011-01-01

    Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032

  10. Basics of biomedical ultrasound for engineers

    CERN Document Server

    Azhari, Haim

    2010-01-01

    "Basics of Biomedical Ultrasound for Engineers is a structured textbook for university engineering courses in biomedical ultrasound and for researchers in the field. This book offers a tool for building a solid understanding of biomedical ultrasound, and leads the novice through the field in a step-by-step manner. The book begins with the most basic definitions of waves, proceeds to ultrasounds in fluids, and then delves into solid ultrasounds, the most complicated kind of ultrasound. It encompasses a wide range of topics within biomedical ultrasound, from conceptual definitions of waves to the intricacies of focusing devices, transducers, and acoustic fields"--Provided by publisher.

  11. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... legs, neck and/or brain (in infants and children) or within various body organs such as the ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... color picture. It can also convert blood flow information into a distinctive sound that can be heard ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can ... ultrasound procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure? Ultrasound examinations can help to diagnose a variety of conditions and to assess organ damage following ... the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, including valve problems and congestive ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... more extensive exams may take up to an hour. When the examination is complete, you may be ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in infections With knowledge about the speed and volume of blood flow gained from a Doppler ultrasound ... the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top of page ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... sonography is performed using the same transducer. Rarely, young children may need to be sedated in order ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... American College of Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  14. Filtering, control and fault detection with randomly occurring incomplete information

    CERN Document Server

    Dong, Hongli; Gao, Huijun

    2013-01-01

    This book investigates the filtering, control and fault detection problems for several classes of nonlinear systems with randomly occurring incomplete information. It proposes new concepts, including RVNs, ROMDs, ROMTCDs, and ROQEs. The incomplete information under consideration primarily includes missing measurements, time-delays, sensor and actuator saturations, quantization effects and time-varying nonlinearities. The first part of this book focuses on the filtering, control and fault detection problems for several classes of nonlinear stochastic discrete-time systems and

  15. L2-Harmonic Forms on Incomplete Riemannian Manifolds with Positive Ricci Curvature

    Directory of Open Access Journals (Sweden)

    Junya Takahashi

    2018-05-01

    Full Text Available We construct an incomplete Riemannian manifold with positive Ricci curvature that has non-trivial L 2 -harmonic forms and on which the L 2 -Stokes theorem does not hold. Therefore, a Bochner-type vanishing theorem does not hold for incomplete Riemannian manifolds.

  16. Effect of projectile on incomplete fusion reactions at low energies

    Directory of Open Access Journals (Sweden)

    Sharma Vijay R.

    2017-01-01

    Full Text Available Present work deals with the experimental studies of incomplete fusion reaction dynamics at energies as low as ≈ 4 - 7 MeV/A. Excitation functions populated via complete fusion and/or incomplete fusion processes in 12C+175Lu, and 13C+169Tm systems have been measured within the framework of PACE4 code. Data of excitation function measurements on comparison with different projectile-target combinations suggest the existence of ICF even at slightly above barrier energies where complete fusion (CF is supposed to be the sole contributor, and further demonstrates strong projectile structure dependence of ICF. The incomplete fusion strength functions for 12C+175Lu, and 13C+169Tm systems are analyzed as a function of various physical parameters at a constant vrel ≈ 0.053c. It has been found that one neutron (1n excess projectile 13C (as compared to 12C results in less incomplete fusion contribution due to its relatively large negative α-Q-value, hence, α Q-value seems to be a reliable parameter to understand the ICF dynamics at low energies. In order to explore the reaction modes on the basis of their entry state spin population, the spin distribution of residues populated via CF and/or ICF in 16O+159Tb system has been done using particle-γ coincidence technique. CF-α and ICF-α channels have been identified from backward (B and forward (F α-gated γspectra, respectively. Reaction dependent decay patterns have been observed in different α emitting channels. The CF channels are found to be fed over a broad spin range, however, ICF-α channels was observed only for high-spin states. Further, the existence of incomplete fusion at low bombarding energies indicates the possibility to populate high spin states

  17. Effect of projectile on incomplete fusion reactions at low energies

    Science.gov (United States)

    Sharma, Vijay R.; Shuaib, Mohd.; Yadav, Abhishek; Singh, Pushpendra P.; Sharma, Manoj K.; Kumar, R.; Singh, Devendra P.; Singh, B. P.; Muralithar, S.; Singh, R. P.; Bhowmik, R. K.; Prasad, R.

    2017-11-01

    Present work deals with the experimental studies of incomplete fusion reaction dynamics at energies as low as ≈ 4 - 7 MeV/A. Excitation functions populated via complete fusion and/or incomplete fusion processes in 12C+175Lu, and 13C+169Tm systems have been measured within the framework of PACE4 code. Data of excitation function measurements on comparison with different projectile-target combinations suggest the existence of ICF even at slightly above barrier energies where complete fusion (CF) is supposed to be the sole contributor, and further demonstrates strong projectile structure dependence of ICF. The incomplete fusion strength functions for 12C+175Lu, and 13C+169Tm systems are analyzed as a function of various physical parameters at a constant vrel ≈ 0.053c. It has been found that one neutron (1n) excess projectile 13C (as compared to 12C) results in less incomplete fusion contribution due to its relatively large negative α-Q-value, hence, α Q-value seems to be a reliable parameter to understand the ICF dynamics at low energies. In order to explore the reaction modes on the basis of their entry state spin population, the spin distribution of residues populated via CF and/or ICF in 16O+159Tb system has been done using particle-γ coincidence technique. CF-α and ICF-α channels have been identified from backward (B) and forward (F) α-gated γspectra, respectively. Reaction dependent decay patterns have been observed in different α emitting channels. The CF channels are found to be fed over a broad spin range, however, ICF-α channels was observed only for high-spin states. Further, the existence of incomplete fusion at low bombarding energies indicates the possibility to populate high spin states

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  1. Investigation of the effect of power ultrasound on the nucleation of water during freezing of agar gel samples in tubing vials.

    Science.gov (United States)

    Kiani, Hossein; Sun, Da-Wen; Delgado, Adriana; Zhang, Zhihang

    2012-05-01

    Nucleation, as an important stage of freezing process, can be induced by the irradiation of power ultrasound. In this study, the effect of irradiation temperature (-2 °C, -3 °C, -4 °C and -5 °C), irradiation duration (0s, 1s, 3s, 5s, 10s or 15s) and ultrasound intensity (0.07 W cm(-2), 0.14 W cm(-2), 0.25 W cm(-2), 0.35 W cm(-2) and 0.42 W cm(-2)) on the dynamic nucleation of ice in agar gel samples was studied. The samples were frozen in an ethylene glycol-water mixture (-20 °C) in an ultrasonic bath system after putting them into tubing vials. Results indicated that ultrasound irradiation is able to initiate nucleation at different supercooled temperatures (from -5 °C to -2 °C) in agar gel if optimum intensity and duration of ultrasound were chosen. Evaluation of the effect of 0.25 W cm(-2) ultrasound intensity and different durations of ultrasound application on agar gels showed that 1s was not long enough to induce nucleation, 3s induced the nucleation repeatedly but longer irradiation durations resulted in the generation of heat and therefore nucleation was postponed. Investigation of the effect of ultrasound intensity revealed that higher intensities of ultrasound were effective when a shorter period of irradiation was used, while lower intensities only resulted in nucleation when a longer irradiation time was applied. In addition to this, higher intensities were not effective at longer irradiation times due to the heat generated in the samples by the heating effect of ultrasound. In conclusion, the use of ultrasound as a means to control the crystallization process offers promising application in freezing of solid foods, however, optimum conditions should be selected. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Ultrasound surface probe as a screening method for evaluating the patients with blunt abdominal trauma

    Directory of Open Access Journals (Sweden)

    Mohammad Nasr-Esfahani

    2014-01-01

    Full Text Available Background: Blunt abdominal trauma is one of the causes of mortality in emergency department. Free fluid in the abdomen due to intra-abdominal blunt trauma can be determined by the surface probe of ultrasound. Since the importance of this free fluid in hemodynamic stable patients with blunt trauma is associated with the unknown outcome for surgeons, this study was performed to evaluate the role of ultrasound surface probe as a screening method in evaluating the patients with blunt abdominal trauma. Materials and Methods: A descriptive-analytical study was done on 45 patients with blunt abdominal trauma and hemodynamic stability. The patients were evaluated twice during the three-hours, including repeated ultrasound surface probe and clinical examinations. Computerized tomography was also performed. The patients were divided based on the amount of the free fluid in the abdomen during the evaluations into two groups: Fixed or increased, and decreased free fluid. The results of the different evaluated methods were compared using the sensitivity and specificity. Results: From 17 patients with CT abnormalities, free fluid increased in 14 patients (82.4%. Free fluid was decreased in three patients who were discharged well from the surgery service without any complication. Surface probe in prognosis detection had a sensitivity of 82.4% and specificity of 92.9%. The percentage of false positive and negative ultrasound compared with CT scan was 7.1% and 17.6%. Also, positive and negative predictive value of the ultrasound with surface probe was 87.5% and 89.7% respectively. Conclusion: The use of the ultrasound with surface probe in the diagnosis of free fluid in blunt abdominal trauma in hemodynamic stable patients can be considered as a useful screening method.

  3. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the ... abdomen using ultrasound. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  6. Root cause of incomplete control rod insertions at Westinghouse reactors

    International Nuclear Information System (INIS)

    Ray, S.

    1997-01-01

    Within the past year, incomplete RCCA insertions have been observed on high burnup fuel assemblies at two Westinghouse PWRs. Initial tests at the Wolf Creek site indicated that the direct cause of the incomplete insertions observed at Wolf Creek was excessive fuel assembly thimble tube distortion. Westinghouse committed to the NRC to perform a root cause analysis by the end of August, 1996. The root cause analysis process used by Westinghouse included testing at ten sites to obtain drag, growth and other characteristics of high burnup fuel assemblies. It also included testing at the Westinghouse hot cell of two of the Wolf Creek incomplete insertion assemblies. A mechanical model was developed to calculate the response of fuel assemblies when subjected to compressive loads. Detailed manufacturing reviews were conducted to determine if this was a manufacturing related issue. In addition, a review of available worldwide experience was performed. Based on the above, it was concluded that the thimble tube distortion observed on the Wolf Creek incomplete insertion assemblies was caused by unusual fuel assembly growth over and above what would typically be expected as a result of irradiation exposure. It was determined that the unusual growth component is a combination of growth due to oxide accumulation and accelerated growth, and would only be expected in high temperature plants on fuel assemblies that see long residence times and high power duties

  7. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    Science.gov (United States)

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at

  8. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  9. The effects of incomplete protein interaction data on structural and evolutionary inferences

    DEFF Research Database (Denmark)

    de Silva, E; Thorne, T; Ingram, P

    2006-01-01

    of the inherent noise in protein interaction data. The effects of the incomplete nature of network data become very noticeable, especially for so-called network motifs. We also consider the effect of incomplete network data on functional and evolutionary inferences. Conclusion Crucially, when only small, partial...

  10. Effect of projectile structure on evaporation residue yields in incomplete fusion reactions

    CERN Document Server

    Babu, K S; Sudarshan, K; Shrivastava, B D; Goswami, A; Tomar, B S

    2003-01-01

    The excitation functions of heavy residues, representing complete and incomplete fusion products, produced in the reaction of sup 1 sup 2 C and sup 1 sup 3 C on sup 1 sup 8 sup 1 Ta have been measured over the projectile energy range of 5 to 6.5 MeV/nucleon by the recoil catcher method and off-line gamma-ray spectrometry. Comparison of the measured excitation functions with those calculated using the PACE2 code based on the statistical model revealed the occurrence of incomplete fusion reactions in the formation of alpha emission products. The fraction of incomplete fusion cross sections in the sup 1 sup 2 C + sup 1 sup 8 sup 1 Ta reaction was found to be higher, by a factor of approx 2, than that in the sup 1 sup 3 C + sup 1 sup 8 sup 1 Ta reaction. The results have been discussed in terms of the effect of alpha cluster structure of the projectile on incomplete fusion reactions.

  11. Intraoperative ultrasound to facilitate removal of a submucosal foreign body.

    Science.gov (United States)

    Smith, Matthew E; Riffat, Faruque; Berman, Laurence H; Jani, Piyush

    2014-01-01

    A 61-year-old man with a history of fish bone ingestion and poorly localized symptoms was seen. His clinical examination was unremarkable, but CT demonstrated a foreign body deeply embedded within his tongue. Intraoperative ultrasound (US) guidance facilitated identification of a bone, allowing a needle to be placed as a guide to dissection. Repeat US scanning through the incision permitted precisely targeted surgery. CT and US are the most effective imaging techniques for localizing fish bones. Intraoperative US can be used to accurately locate a submucosal fish bone in mobile tissue such as the tongue, and focused, image-guided dissection can reduce surgical tissue trauma. © 2014 Wiley Periodicals, Inc.

  12. Transfection effect of microbubbles on cells in superposed ultrasound waves and behavior of cavitation bubble.

    Science.gov (United States)

    Kodama, Tetsuya; Tomita, Yukio; Koshiyama, Ken-Ichiro; Blomley, Martin J K

    2006-06-01

    The combination of ultrasound and ultrasound contrast agents (UCAs) is able to induce transient membrane permeability leading to direct delivery of exogenous molecules into cells. Cavitation bubbles are believed to be involved in the membrane permeability; however, the detailed mechanism is still unknown. In the present study, the effects of ultrasound and the UCAs, Optison on transfection in vitro for different medium heights and the related dynamic behaviors of cavitation bubbles were investigated. Cultured CHO-E cells mixed with reporter genes (luciferase or beta-gal plasmid DNA) and UCAs were exposed to 1 MHz ultrasound in 24-well plates. Ultrasound was applied from the bottom of the well and reflected at the free surface of the medium, resulting in the superposition of ultrasound waves within the well. Cells cultured on the bottom of 24-well plates were located near the first node (displacement node) of the incident ultrasound downstream. Transfection activity was a function determined with the height of the medium (wave traveling distance), as well as the concentration of UCAs and the exposure time was also determined with the concentration of UCAs and the exposure duration. Survival fraction was determined by MTT assay, also changes with these values in the reverse pattern compared with luciferase activity. With shallow medium height, high transfection efficacy and high survival fraction were obtained at a low concentration of UCAs. In addition, capillary waves and subsequent atomized particles became significant as the medium height decreased. These phenomena suggested cavitation bubbles were being generated in the medium. To determine the effect of UCAs on bubble generation, we repeated the experiments using crushed heat-treated Optison solution instead of the standard microbubble preparation. The transfection ratio and survival fraction showed no additional benefit when ultrasound was used. These results suggested that cavitation bubbles created by the

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  14. The use of three-dimensional ultrasound does not improve training in fetal biometric measurements.

    Science.gov (United States)

    Chan, Lin W; Ting, Yuen H; Lao, Terence T; Chau, Macy M C; Fung, Tak Y; Leung, Tak Y; Sahota, Daljit S; Lau, Tze K

    2011-09-01

    To investigate whether three-dimensional (3D) technology offers any advantage over two-dimensional (2D) ultrasound in fetal biometric measurement training. Ten midwives with no hands-on experience in ultrasound were randomized to receive training on 2D or 3D ultrasound fetal biometry assessment. Midwives were taught how to obtain fetal biometric measurements (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL)) by a trainer. Subsequently, each midwife measured the parameters on another 10 fetuses. The same set of measurements was repeated by the trainer. The percentage deviation between the midwives' and the trainer's measurements was determined and compared between training groups. Time required for completion was recorded. Frozen images were reviewed by another sonographer to assess the image quality using a standardized scoring system. The median time for the complete set of measurements was significantly shorter in the 2D than in 3D group (13.4 min versus 17.8 min, P = 0.03). The mean percentage deviations did not reach statistical significance between the two groups except for FL (3.83% in 2D group versus 2.23% in 3D group (P = 0.046)). There were no significant differences in the quality scores. This study showed that the only demonstrable advantage of 3D ultrasound was a slightly more accurate measurement of FL, at the expense of a significantly longer time required.

  15. Radiological findings and healing patterns of incomplete stress fractures of the pars interarticularis

    International Nuclear Information System (INIS)

    Dunn, Andrew J.; Campbell, Robert S.D.; Mayor, Peter E.; Rees, Dai

    2008-01-01

    The objective was to retrospectively record the CT and MRI features and healing patterns of acute, incomplete stress fractures of the pars interarticularis. The CT scans of 156 adolescents referred with suspected pars interarticularis stress fractures were reviewed. Patients with incomplete (grade 2) pars fractures were included in the study. Fractures were assessed on CT according to vertebral level, location of cortical involvement and direction of fracture propagation. MRI was also performed in 72 of the 156 cases. MRI images of incomplete fractures were assessed for the presence of marrow oedema and cortical integrity. Fracture healing patterns were characterised on follow-up CT imaging. Twenty-five incomplete fractures were identified in 23 patients on CT. All fractures involved the inferior or infero-medial cortex of the pars and propagated superiorly or superolaterally. Ninety-two percent of incomplete fractures demonstrated either complete or partial healing on follow-up imaging. Two (8%) cases progressed to complete fractures. Thirteen incomplete fractures in 11 patients confirmed on CT also had MRI, and 92% demonstrated oedema in the pars. Ten out of thirteen fractures (77%) showed a break in the infero-medial cortex with intact supero-lateral cortex, which correlated with the CT findings. MRI incorrectly graded one case as a complete (grade 3) fracture, and 2 cases as (grade 1) stress reaction. Six fractures had follow-up MRI, 67% showed partial or complete cortical healing, and the same number showed persistent marrow oedema. Incomplete fracture of the pars interarticularis represents a stage of the evolution of a complete stress fracture. The direction of fracture propagation is consistent, and complete healing can be achieved in most cases with appropriate clinical management. CT best demonstrates fracture size and extent, and is the most appropriate modality for follow-up. MRI is limited in its ability to fully depict the cortical integrity of

  16. Radiological findings and healing patterns of incomplete stress fractures of the pars interarticularis

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Andrew J.; Campbell, Robert S.D. [Royal Liverpool and Broadgreen University Teaching Hospitals, Department of Medical Imaging, Liverpool (United Kingdom); Mayor, Peter E. [Leighton Hospital, Department of Medical Imaging, Crewe, Cheshire (United Kingdom); Rees, Dai [Robert Jones and Agnes-Hunt Orthopaedic Hospital, Department of Orthopaedic Surgery, Oswestry, Shropshire (United Kingdom)

    2008-05-15

    The objective was to retrospectively record the CT and MRI features and healing patterns of acute, incomplete stress fractures of the pars interarticularis. The CT scans of 156 adolescents referred with suspected pars interarticularis stress fractures were reviewed. Patients with incomplete (grade 2) pars fractures were included in the study. Fractures were assessed on CT according to vertebral level, location of cortical involvement and direction of fracture propagation. MRI was also performed in 72 of the 156 cases. MRI images of incomplete fractures were assessed for the presence of marrow oedema and cortical integrity. Fracture healing patterns were characterised on follow-up CT imaging. Twenty-five incomplete fractures were identified in 23 patients on CT. All fractures involved the inferior or infero-medial cortex of the pars and propagated superiorly or superolaterally. Ninety-two percent of incomplete fractures demonstrated either complete or partial healing on follow-up imaging. Two (8%) cases progressed to complete fractures. Thirteen incomplete fractures in 11 patients confirmed on CT also had MRI, and 92% demonstrated oedema in the pars. Ten out of thirteen fractures (77%) showed a break in the infero-medial cortex with intact supero-lateral cortex, which correlated with the CT findings. MRI incorrectly graded one case as a complete (grade 3) fracture, and 2 cases as (grade 1) stress reaction. Six fractures had follow-up MRI, 67% showed partial or complete cortical healing, and the same number showed persistent marrow oedema. Incomplete fracture of the pars interarticularis represents a stage of the evolution of a complete stress fracture. The direction of fracture propagation is consistent, and complete healing can be achieved in most cases with appropriate clinical management. CT best demonstrates fracture size and extent, and is the most appropriate modality for follow-up. MRI is limited in its ability to fully depict the cortical integrity of

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the ... abdomen using ultrasound. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ... 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations ...

  19. How reassuring is a normal breast ultrasound in assessment of a screen-detected mammographic abnormality? A review of interval cancers after assessment that included ultrasound evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, M.L. [Breastscreen WA, Perth (Australia); Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Welman, C.J. [Breastscreen WA, Perth (Australia); Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Department of Radiology, Fremantle Hospital and Health Service, Fremantle (Australia); Celliers, L.M., E-mail: liesl.celliers@health.wa.gov.au [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Department of Radiology, Fremantle Hospital and Health Service, Fremantle (Australia)

    2011-10-15

    Aim: To review factors resulting in a false-negative outcome or delayed cancer diagnosis in women recalled for further evaluation, including ultrasound, after an abnormal screening mammogram. Materials and methods: Of 646,692 screening mammograms performed between 1 January 1995 and 31 December 2004, 34,533 women were recalled for further assessment. Nine hundred and sixty-four interval cancers were reported in this period. Forty-six of these women had been recalled for further assessment, which specifically included ultrasound evaluation in the preceding 24 months, and therefore, met the inclusion criteria for this study. Screening mammograms, further mammographic views, ultrasound scans, clinical findings, and histopathology results were retrospectively reviewed by two consultant breast radiologists. Results: The interval cancer developed in the contralateral breast (n = 9), ipsilateral breast, but different site (n = 6), and ipsilateral breast at the same site (n = 31) as the abnormality for which they had recently been recalled. In the latter group, 10 were retrospectively classified as a false-negative outcome, nine had a delay in obtaining a biopsy, and 12 had a delay due to a non-diagnostic initial biopsy. Various factors relating to these outcomes are discussed. Conclusion: Out of 34,533 women who attended for an assessment visit and the 46 women who subsequently developed an interval breast cancer, 15 were true interval cancers, 10 had a false-negative assessment outcome, and 21 had a delay to cancer diagnosis on the basis of a number of factors. When there is discrepancy between the imaging and histopathology results, a repeat biopsy rather than early follow-up would have avoided a delay in some cases. A normal ultrasound examination should not deter the radiologist from proceeding to stereotactic biopsy, if the index mammographic lesion is suspicious of malignancy.

  20. Research interface on a programmable ultrasound scanner.

    Science.gov (United States)

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research

  1. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  3. 10 CFR 782.7 - Incomplete notice of infringement.

    Science.gov (United States)

    2010-01-01

    ... presented; and (2) Of the elements considered necessary to establish a claim. (b) A communication, such as a... § 782.7 Incomplete notice of infringement. (a) If a communication alleging patent or copyright...

  4. Automated 3D ultrasound measurement of the angle of progression in labor.

    Science.gov (United States)

    Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly

    2018-01-01

    To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.

  5. Quantitative ultrasound characterization of tumor cell death: ultrasound-stimulated microbubbles for radiation enhancement.

    Directory of Open Access Journals (Sweden)

    Hyunjung Christina Kim

    Full Text Available The aim of this study was to assess the efficacy of quantitative ultrasound imaging in characterizing cancer cell death caused by enhanced radiation treatments. This investigation focused on developing this ultrasound modality as an imaging-based non-invasive method that can be used to monitor therapeutic ultrasound and radiation effects. High-frequency (25 MHz ultrasound was used to image tumor responses caused by ultrasound-stimulated microbubbles in combination with radiation. Human prostate xenografts grown in severe combined immunodeficiency (SCID mice were treated using 8, 80, or 1000 µL/kg of microbubbles stimulated with ultrasound at 250, 570, or 750 kPa, and exposed to 0, 2, or 8 Gy of radiation. Tumors were imaged prior to treatment and 24 hours after treatment. Spectral analysis of images acquired from treated tumors revealed overall increases in ultrasound backscatter intensity and the spectral intercept parameter. The increase in backscatter intensity compared to the control ranged from 1.9±1.6 dB for the clinical imaging dose of microbubbles (8 µL/kg, 250 kPa, 2 Gy to 7.0±4.1 dB for the most extreme treatment condition (1000 µL/kg, 750 kPa, 8 Gy. In parallel, in situ end-labelling (ISEL staining, ceramide, and cyclophilin A staining demonstrated increases in cell death due to DNA fragmentation, ceramide-mediated apoptosis, and release of cyclophilin A as a result of cell membrane permeabilization, respectively. Quantitative ultrasound results indicated changes that paralleled increases in cell death observed from histology analyses supporting its use for non-invasive monitoring of cancer treatment outcomes.

  6. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  7. Incomplete Contract and Divisional Structures

    OpenAIRE

    Bao, T.; Wang, Y.

    2009-01-01

    In this paper we want to analyze the internal divisional structure within an organi- zation in the framework of incomplete contract theory. We use the framework of Aghion and Tirole (1997) and define the managerial control structure as \\sequence of search". A key feature of this paper which differentiate it from other works in the literature is that we add add an ex post bargaining phase in which the managers can agree on the project which maximize their joint private benefit. Our model shows...

  8. Another look at the second incompleteness theorem

    NARCIS (Netherlands)

    Visser, A.

    2017-01-01

    In this paper we study proofs of some general forms of the Second Incompleteness Theorem. These forms conform to the Feferman format, where the proof predicate is xed and the representation of the axiom set varies. We extend the Feferman framework in one important point: we allow the interpretation

  9. Another look at the second incompleteness theorem

    NARCIS (Netherlands)

    Visser, Albert

    2017-01-01

    In this paper we study proofs of some general forms of the Second Incompleteness Theorem. These forms conform to the Feferman format, where the proof predicate is fixed and the representation of the axiom set varies. We extend the Feferman framework in one important point: we allow the

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... is Abdominal Ultrasound Imaging? What are some common uses of the procedure? How should we prepare for an ultrasound exam? What does the ultrasound equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. An ultrasound examination is usually ...

  12. Developing an emergency ultrasound app

    DEFF Research Database (Denmark)

    Foss, Kim Thestrup; Subhi, Yousif; Aagaard, Rasmus

    2015-01-01

    Focused emergency ultrasound is rapidly evolving as a clinical skill for bedside examination by physicians at all levels of education. Ultrasound is highly operator-dependent and relevant training is essential to ensure appropriate use. When supplementing hands-on focused ultrasound courses, e-le...

  13. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    International Nuclear Information System (INIS)

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  14. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  15. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  16. Physics of Ultrasound. Chapter 12

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    Ultrasound is the most commonly used diagnostic imaging modality, accounting for approximately 25% of all imaging examinations performed worldwide at the beginning of the 21st century. The success of ultrasound may be attributed to a number of attractive characteristics, including the relatively low cost and portability of an ultrasound scanner, the non-ionizing nature of ultrasound waves, the ability to produce real time images of blood flow and moving structures such as the beating heart, and the intrinsic contrast among soft tissue structures that is achieved without the need for an injected contrast agent. The latter characteristic enables ultrasound to be used for a wide range of medical applications, which historically have primarily included cardiac and vascular imaging, imaging of the abdominal organs and, most famously, in utero imaging of the developing fetus. Ongoing technological improvements continue to expand the use of ultrasound for many applications, including cancer imaging, musculoskeletal imaging, ophthalmology and others. The term ultrasound refers specifically to acoustic waves at frequencies greater than the maximum frequency audible to humans, which is nominally 20 kHz. Diagnostic imaging is generally performed using ultrasound in the frequency range of 2–15 MHz. The choice of frequency is dictated by a trade off between spatial resolution and penetration depth, since higher frequency waves can be focused more tightly but are attenuated more rapidly by tissue. The information contained in an ultrasonic image is influenced by the physical processes underlying propagation, reflection and attenuation of ultrasound waves in tissue.

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to image by ultrasound because greater amounts of tissue attenuate (weaken) the sound waves as they pass deeper into the body and need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can only see the outer surface ...

  18. [Basics of emergency ultrasound].

    Science.gov (United States)

    Schellhaas, S; Breitkreutz, R

    2012-09-05

    Focused ultrasound is a key methodology of critical care medicine. By referencing few ultrasound differential diagnosis, it is possible to identifying in real-time the reason of the critical state of a patient. Therefore typical focused ultrasound protocols were developed. The well known Focused Assessment with Sonography for trauma (FAST) was incorporated into the Advanced Trauma Life Support (ATLS) for shock room. Focused echocardiographic evaluation in life support (FEEL) has been designed to be conformed with the universal Advanced Life Support (ALS) algorithm and to identify treatable conditions such as acute right ventricular pressure overload in pulmonary embolism, hypovolemia, or pericardial effusion/tamponade. Using lung ultrasound one can differentiate pulmonary edema, pleural effusion or pneumothorax.

  19. Incompletely characterized incidental renal masses: emerging data support conservative management.

    Science.gov (United States)

    Silverman, Stuart G; Israel, Gary M; Trinh, Quoc-Dien

    2015-04-01

    With imaging, most incidental renal masses can be diagnosed promptly and with confidence as being either benign or malignant. For those that cannot, management recommendations can be devised on the basis of a thorough evaluation of imaging features. However, most renal masses are either too small to characterize completely or are detected initially in imaging examinations that are not designed for full evaluation of them. These masses constitute a group of masses that are considered incompletely characterized. On the basis of current published guidelines, many masses warrant additional imaging. However, while the diagnosis of renal cancer at a curable stage remains the first priority, there is the additional need to reduce unnecessary healthcare costs and radiation exposure. As such, emerging data now support foregoing additional imaging for many incompletely characterized renal masses. These data include the low risk of progression to metastases or death for small renal masses that have undergone active surveillance (including biopsy-proven cancers) and a better understanding of how specific imaging features can be used to diagnose their origins. These developments support (a) avoidance of imaging entirely for those incompletely characterized renal masses that are highly likely to be benign cysts and (b) delay of further imaging of small solid masses in selected patients. Although more evidence-based data are needed and comprehensive management algorithms have yet to be defined, these recommendations are medically appropriate and practical, while limiting the imaging of many incompletely characterized incidental renal masses.

  20. Ultrasound call detection in capybara

    Directory of Open Access Journals (Sweden)

    Selene S.C. Nogueira

    2012-07-01

    Full Text Available The vocal repertoire of some animal species has been considered a non-invasive tool to predict distress reactivity. In rats ultrasound emissions were reported as distress indicator. Capybaras[ vocal repertoire was reported recently and seems to have ultrasound calls, but this has not yet been confirmed. Thus, in order to check if a poor state of welfare was linked to ultrasound calls in the capybara vocal repertoire, the aim of this study was to track the presence of ultrasound emissions in 11 animals under three conditions: 1 unrestrained; 2 intermediately restrained, and 3 highly restrained. The ultrasound track identified frequencies in the range of 31.8±3.5 kHz in adults and 33.2±8.5 kHz in juveniles. These ultrasound frequencies occurred only when animals were highly restrained, physically restrained or injured during handling. We concluded that these calls with ultrasound components are related to pain and restraint because they did not occur when animals were free of restraint. Thus we suggest that this vocalization may be used as an additional tool to assess capybaras[ welfare.

  1. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  2. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    Science.gov (United States)

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  3. Pancreas divisum as a possible cause of misinterpretation in ERCP, computed tomography, ultrasound and barium meal

    International Nuclear Information System (INIS)

    Brambs, H.J.; Schuetz, B.; Wimmer, B.; Hoppe-Seyler, P.; Freiburg Univ.

    1986-01-01

    In 488 patients endoscopic retorgrade pancreatography (ERP) revealed a pancreas divisum in 21 (4.3%): in 17/21 patients we found a complete, in 4/21 an incomplete separation of the pancreatic ducts. The pancreas divisum is caused by a malfusion of the ductal system. On examination by ultrasound, computed tomography or hypotonic duodenography this variant can suggest an inflammation or tumour of the head of the pancreas. A definite diagnosis is possible by ERP only. Since the small ventral duct can be confused with an alteration caused by inflammation or by a tumour, to much of contrast medium can be injected. Pancreas divisum is often associated with a chronic pancreatitis which can be demonstrated via ERP of the dorsal duct through the accessory papilla. (orig.) [de

  4. Ultrasound in environmental engineering. Papers

    Energy Technology Data Exchange (ETDEWEB)

    Tiehm, A; Neis, U [eds.

    1999-07-01

    This book presents recent research and state-of-the-art information on the scientific basis, modes of use, and engineering developments of ultrasound application in the field of environmental protection. The information is loosely grouped into the following themes: ultrasound and sonochemistry, design of sonoreactors, applications in water, waste water and sludge treatment: aggregation of suspended particles, degradation of hazardous pollutants, disinfection, disintegration of biosolids. Ultrasound is generated and applied at frequencies from 20 kHz to several MHz. Reactor design, applied intensity, duration of sonication, and physico-chemical parameters of the sonicated media influence ultrasound effects. Thus, ultrasound, at a first glance, is a complex and probably confusing matter. This book has been compiled from presentations held at the first workshop 'Ultrasound in Environmental Engineering' on March 22nd and 23rd, 1999, at the Technical University of Hamburg-Harburg in cooperation with the German Association for the Water Environment (ATV) and the DECHEMA e.V. (orig.)

  5. Ultrasound in environmental engineering. Papers

    Energy Technology Data Exchange (ETDEWEB)

    Tiehm, A.; Neis, U. [eds.

    1999-07-01

    This book presents recent research and state-of-the-art information on the scientific basis, modes of use, and engineering developments of ultrasound application in the field of environmental protection. The information is loosely grouped into the following themes: ultrasound and sonochemistry, design of sonoreactors, applications in water, waste water and sludge treatment: aggregation of suspended particles, degradation of hazardous pollutants, disinfection, disintegration of biosolids. Ultrasound is generated and applied at frequencies from 20 kHz to several MHz. Reactor design, applied intensity, duration of sonication, and physico-chemical parameters of the sonicated media influence ultrasound effects. Thus, ultrasound, at a first glance, is a complex and probably confusing matter. This book has been compiled from presentations held at the first workshop 'Ultrasound in Environmental Engineering' on March 22nd and 23rd, 1999, at the Technical University of Hamburg-Harburg in cooperation with the German Association for the Water Environment (ATV) and the DECHEMA e.V. (orig.)

  6. Low Complexity Models to improve Incomplete Sensitivities for Shape Optimization

    Science.gov (United States)

    Stanciu, Mugurel; Mohammadi, Bijan; Moreau, Stéphane

    2003-01-01

    The present global platform for simulation and design of multi-model configurations treat shape optimization problems in aerodynamics. Flow solvers are coupled with optimization algorithms based on CAD-free and CAD-connected frameworks. Newton methods together with incomplete expressions of gradients are used. Such incomplete sensitivities are improved using reduced models based on physical assumptions. The validity and the application of this approach in real-life problems are presented. The numerical examples concern shape optimization for an airfoil, a business jet and a car engine cooling axial fan.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... women and their unborn babies. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  8. Molecular ultrasound imaging: current status and future directions

    International Nuclear Information System (INIS)

    Deshpande, N.; Needles, A.; Willmann, J.K.

    2010-01-01

    Targeted contrast-enhanced ultrasound (molecular ultrasound) is an emerging imaging strategy that combines ultrasound technology with novel molecularly-targeted ultrasound contrast agents for assessing biological processes at the molecular level. Molecular ultrasound contrast agents are nano- or micro-sized particles that are targeted to specific molecular markers by adding high-affinity binding ligands onto the surface of the particles. Following intravenous administration, these targeted ultrasound contrast agents accumulate at tissue sites overexpressing specific molecular markers, thereby enhancing the ultrasound imaging signal. High spatial and temporal resolution, real-time imaging, non-invasiveness, relatively low costs, lack of ionising irradiation and wide availability of ultrasound systems are advantages compared to other molecular imaging modalities. In this article we review current concepts and future directions of molecular ultrasound imaging, including different classes of molecular ultrasound contrast agents, ongoing technical developments of pre-clinical and clinical ultrasound systems, the potential of molecular ultrasound for imaging different diseases at the molecular level, and the translation of molecular ultrasound into the clinic.

  9. Management strategy for symptomatic bisphosphonate-associated incomplete atypical femoral fractures.

    Science.gov (United States)

    Saleh, Anas; Hegde, Vishal V; Potty, Anish G; Schneider, Robert; Cornell, Charles N; Lane, Joseph M

    2012-07-01

    Long-term bisphosphonate use has often been associated with atypical femoral fractures. These fractures evolve from incomplete femoral fractures. A previous study demonstrated that the presence of a radiolucent line in an incomplete fracture can indicate a high risk of progression to complete fracture. The aim of this study is to present a management strategy for symptomatic bisphosphonate-associated incomplete atypical femoral fractures. Specific study questions include the following: (1) Is there a difference in the prognosis of these fractures based on the presence or absence of a radiolucent fracture line? (2) Can treatment with teriparatide assist in clinical/radiographic healing of these incomplete fractures? (3) Is there a characteristic biochemical profile in these patients? We retrospectively examined all femur radiographs ordered by the metabolic bone disease service at our hospital between July 1, 2006 and July 1, 2011 and identified 10 patients with a total of 14 incomplete fractures. Nine patients received bisphosphonates for a mean duration of 10 ± 5 years (range, 4-17). The mean follow-up since the time of diagnosis was 20 ± 11 months (range, 6-36 months). Five fractures did not have a radiolucent fracture line and were treated conservatively with partial weight-bearing restrictions and pharmacologic therapy. All five of these fractures healed with conservative management. Nine fractures had a radiolucent fracture line, and only two of these were treated successfully with conservative management including teriparatide. Six of the eight patients with a radiolucent line elected for surgical prophylaxis after 3 months of conservative management, whereas one patient underwent surgical prophylaxis without a trial of conservative management. Regarding the biochemical profiles, bone turnover markers for our patient cohort were in the lower quartile. Fractures without a radiolucent line appear to respond to conservative management and not

  10. Prostate ultrasound: back in business!

    Science.gov (United States)

    Crisan, Nicolae; Andras, Iulia; Radu, Corina; Andras, David; Coman, Radu-Tudor; Tucan, Paul; Pisla, Doina; Crisan, Dana; Coman, Ioan

    2017-11-29

    The use of grey scale prostate ultrasound decreased after the implementation of magnetic resonance imaging (MRI) for the diagnosis and evaluation of prostate cancer. The new developments, such as multiparametric ultrasound and MRI-ultrasound fusion technology, renewed the interest for this imaging method in the assessment of prostate cancer. The purpose of this paper was to review the current role of prostate ultrasound in the setting of these new applications. A thorough reevaluation of the selection criteria of the patients is required to assess which patients would benefit from multiparametric ultrasound, who wouldbenefit from multiparametric MRI or the combination of both to assist prostate biopsy in order to ensure the balance between overdiagnosis and underdiagnosis of prostate cancer.

  11. Scintigraphic diagnosis of stress-induced incomplete fractures of the proximal tibia

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Akhtar, K.; Isitman, A.T.

    1984-01-01

    Incomplete stress fractures of the proximal tibial diaphysis can be diagnosed by bone scintigraphy. The scintigraphic appearance of incomplete rather than complete tibial stress fractures is apparently reported for the first time in this article. With no treatment other than restricted activity, this injury heals rapidly and completely in 4 to 6 weeks. The major threat to the patient's welfare is unfounded suspicion of tumor or infection which may lead to biopsy or inappropriate therapy

  12. Initial incomplete surgery modifies prognosis in advanced ovarian cancer regardless of subsequent management.

    Science.gov (United States)

    Bacalbasa, Nicolae; Balescu, Irina; Dima, Simona; Herlea, Vlad; David, Leonard; Brasoveanu, Vladislav; Popescu, Irinel

    2015-04-01

    Prognosis in ovarian cancer is determined by completeness of cytoreduction and proper management by specialized oncological gynecologists. Incomplete initial debulking surgery in non-specialized Centers is, however, a reality and there is ongoing discussion about the best subsequent management of such patients. Patients with advanced ovarian cancer (International Federation of Gynecology and Obstetrics--FIGO FIGO stages IIIC-IV) who had biopsy by laparotomy or incomplete cytoreduction followed or not by chemotherapy further referred to our Institution between January 2002 and May 2014 were included. The two groups of incomplete cytoreduction [followed by upfront surgery or followed by chemotherapy and interval debulking surgery (IDS)] were compared and also compared against a cohort of 197 patients with similar characteristics who underwent upfront maximal surgery according to the standard at our Iinstitution during the same period. A total of 99 eligible patients were identified. Sixty-seven of them underwent biopsies by laparotomy and 32 underwent incomplete cytoreduction in other institutions. Twenty-eight patients underwent direct re-operation while 71 patients underwent neoadjuvant chemotherapy followed by IDS. The mean overall survival duration for patients with upfront reoperation was 31 months and 54 months for patients with neoadjuvant chemotherapy and IDS, considerably lower than the 72 months obtained for the group of 197 patients with maximal up-front complete cytoreduction at our Institution. Primary biopsy or incomplete cytoreduction reduces survival regardless of the subsequent approach. However, if incomplete cytoreduction has occurred, neoadjuvant chemotherapy followed by IDS is preferable to up-front reoperation. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  13. Indications for repeated enema reduction of intussusception in children

    Directory of Open Access Journals (Sweden)

    Vujović Dragana

    2014-01-01

    Full Text Available Introduction. Intussusception is a common abdominal emergency in early childhood. It is idiopathic in more than 90% of cases with incidence of 1.5-4 per 1,000 live births. The treatment of choice is nonoperative hydrostatic or air enema reduction. Objective. The aim of the study was to evaluate the influence of clinical presentation and symptom duration in non-operative treatment, considering the indications for delayed enema reduction and its efficacy. Methods. From the total number of 107 patients with intusussception, aged from 2 months to 14 years (median 9 months, 102 (95% patients with ileo-colic intussusceptions were treated initially by ultrasound guided saline enema. Records were reviewed for patients with failed initial treatment and delayed repeated enemas or operative procedure. The predictor variable included duration of presenting symptoms. Results. Successful treatment by hydrostatic saline enemas had 58/102 (57% patients. Success in reduction was greater if symptom duration was 24 hours, (4/45 cases; 9%. Despite failed initial attempts, enema reduction was reattempted in 12 patients, with success in 7/12 (60% patients. Children with symptom duration >24 hours had a greater risk of requiring surgery (41/45 cases; 91%, p<0.001, including 5 (5% patients with ileo-ileal intussusceptions. Conclusion. The accuracy of ultrasound guided saline enema in intussusception reduction is high. Delay in presentation decreases success of non-operative treatment. Delayed enema reduction is important therapeutic option for intussusceptions. Surgical treatment is indicated in cases of complications.

  14. Prune belly syndrome associated with incomplete VACTERL

    Directory of Open Access Journals (Sweden)

    Ghritlaharey R

    2007-01-01

    Full Text Available A Prune Belly syndrome with VATER/VACTERL association is an extremely rare. They are either stillborn or die within few days of life, only few such cases have been reported in literature. We are presenting here a male neonate of Prune Belly syndrome associated with incomplete VACTERL with brief review of literature.

  15. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Plural Form in Franchising: An Incomplete Contracting Approach

    NARCIS (Netherlands)

    G.W.J. Hendrikse (George); T. Jiang (Tao)

    2005-01-01

    textabstractPlural form franchising is modeled from an incomplete contracting perspective. Complete franchising is the unique, efficient governance structure only when the plural form externality is limited and the costs of investment are low for both franchisees. Governance structure choice is

  17. Ethical analysis of non-medical fetal ultrasound.

    Science.gov (United States)

    Leung, John Lai Yin; Pang, Samantha Mei Che

    2009-09-01

    Obstetric ultrasound is the well-recognized prenatal test used to visualize and determine the condition of a pregnant woman and her fetus. Apart from the clinical application, some businesses have started promoting the use of fetal ultrasound machines for nonmedical reasons. Non-medical fetal ultrasound (also known as 'keepsake' ultrasound) is defined as using ultrasound to view, take a picture, or determine the sex of a fetus without a medical indication. Notwithstanding the guidelines and warnings regarding ultrasound safety issued by governments and professional bodies, the absence of scientifically proven physical harm to fetuses from this procedure seems to provide these businesses with grounds for rapid expansion. However, this argument is too simplistic because current epidemiological evidence is not synchronous with advancing ultrasound technology. As non-medical fetal ultrasound has aroused very significant public attention, a thorough ethical analysis of this topic is essential. Using a multifaceted approach, we analyse the ethical perspective of non-medical fetal ultrasound in terms of the expectant mother, the fetus and health professionals. After applying four major theories of ethics and principles (the precautionary principle; theories of consequentialism and impartiality; duty-based theory; and rights-based theories), we conclude that obstetric ultrasound practice is ethically justifiable only if the indication for its use is based on medical evidence. Non-medical fetal ultrasound can be considered ethically unjustifiable. Nevertheless, the ethical analysis of this issue is time dependent owing to rapid advancements in ultrasound technology and the safety issue. The role of health professionals in ensuring that obstetric ultrasound is an ethically justifiable practice is also discussed.

  18. Low energy incomplete fusion and its relevance to the synthesis of super heavy elements

    Directory of Open Access Journals (Sweden)

    Yadav Abhishek

    2015-01-01

    Full Text Available To study the presence of incomplete fusion at energies around the Coulomb-barrier and to understand its dependence on various entrance-channel parameters, the incomplete fusion fractions have been deduced (i from excitation function measurements for 18O,13,12C+159Tb, and (ii from forward recoil range measurements for 12C+159Tb systems, at low energies (<7MeV/A. The data have been analyzed within the framework of compound nucleus decay, which suggests the production of xn/pxn-channels via complete fusion, as these are found to be well reproduced by PACE4 predictions, while, a significant enhancement in the excitation functions of α-emitting channels has been observed over the theoretical ones, which has been attributed due to the incomplete fusion processes. Further, the incomplete fusion events observed in case of forward recoil ranges have been explained on the basis of the breakup fusion model, where these events may be attributed to the fusion of 8Be and/or 4He from 12C projectile to the target nucleus. For better insight into the underlying dynamics, the deduced fractions of incomplete fusion have been compared with other nearby systems as a function of various entrance channel parameters. The incomplete fusion has been found to be sensitive to the projectile’s energy and alpha-Q-value of the projectile.

  19. Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing.

    Science.gov (United States)

    Sainz, José A; Fernández-Palacín, Ana; Borrero, Carlota; Aquise, Adriana; Ramos, Zenaida; García-Mejido, José A

    2018-04-01

    The aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland-Altman analysis were used to assess intra- and interobserver measurement's repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p pushing under epidural analgesia. Impact statement What is already known on this subject: The intrapartum transperineal ultrasound parameters can be used with contraction and pushing under epidural analgesia. What the results of this study add to what we know: ITU may be used to evaluate the difficulty of instrumental delivery/to evaluate the difficulty of instrumentation in vaginal operative deliveries and this study concludes that ITU is reproducible during uterine contraction with pushing. What the implications are of these findings for clinical practice and/or further research: Therefore, ITU could be used without difficulty with an adequate intra- and interobserver correlation for the prediction of instrumentation difficulty in operative vaginal deliveries.

  20. K-Nearest Neighbor Intervals Based AP Clustering Algorithm for Large Incomplete Data

    Directory of Open Access Journals (Sweden)

    Cheng Lu

    2015-01-01

    Full Text Available The Affinity Propagation (AP algorithm is an effective algorithm for clustering analysis, but it can not be directly applicable to the case of incomplete data. In view of the prevalence of missing data and the uncertainty of missing attributes, we put forward a modified AP clustering algorithm based on K-nearest neighbor intervals (KNNI for incomplete data. Based on an Improved Partial Data Strategy, the proposed algorithm estimates the KNNI representation of missing attributes by using the attribute distribution information of the available data. The similarity function can be changed by dealing with the interval data. Then the improved AP algorithm can be applicable to the case of incomplete data. Experiments on several UCI datasets show that the proposed algorithm achieves impressive clustering results.

  1. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  2. Development of Flexible Capacitive Ultrasound Transducers and the Use of Ultrasound for Bone Repair

    Science.gov (United States)

    Wentzell, Scott A.

    Ultrasound is a widely applicable technique for therapy in the biomedical arena. However, conventional ultrasound transducers are not conducive for non-planar surfaces. Therefore, we developed flexible transducers capable of performing ultrasound and evaluated their use in biomedical applications. Flexible capacitive ultrasound transducers based on micrometer-thick dielectric tapes were developed and fabricated. These transducers were able to be made by hand at low-cost while still demonstrating good tolerances in center operating frequency. Intensities of up to 120 mW/cm2 were recorded and operation was dependent upon the applied AC and DC voltages along with the thickness of the dielectric insulation. These capacitive ultrasound transducers were used to stimulate MC3T3-E1 murine osteoblast cells to investigate the effects of low-frequency ultrasound on osteogenic gene expression and anabolic signaling pathways. After stimulation by 94.5 kHz continuous wave ultrasound for 20 minutes, significant increases in the activation of the Wnt signaling pathway and concentration of intracellular calcium were observed. Daily stimulation by ultrasound showed a trend of increased osteogenic gene expression across the phases of matrix deposition, maturation and calcification by osteoblasts. Finally, the heating of osteoblasts for stimulating osteoclastogenic responses was investigated. The application of increased temperatures of 42 and 47 degrees Celsius for 5 minutes showed significant increases in the RANKL/OPG ratio in media conditioned by osteoblasts. However, the altered RANKL/OPG ratio was not able to generate increases in osteoclastogenesis for RAW 264.7 murine macrophage cells culture in the condition media. This was possibly due to high overall osteoprotegerin expression, or unwanted inducement of M1 and M2 macrophage activation in the cell population. The overall work of this thesis demonstrates the development of novel capacitive transducers. These conformable

  3. The Devil Is in the Details: Incomplete Reporting in Preclinical Animal Research.

    Science.gov (United States)

    Avey, Marc T; Moher, David; Sullivan, Katrina J; Fergusson, Dean; Griffin, Gilly; Grimshaw, Jeremy M; Hutton, Brian; Lalu, Manoj M; Macleod, Malcolm; Marshall, John; Mei, Shirley H J; Rudnicki, Michael; Stewart, Duncan J; Turgeon, Alexis F; McIntyre, Lauralyn

    2016-01-01

    Incomplete reporting of study methods and results has become a focal point for failures in the reproducibility and translation of findings from preclinical research. Here we demonstrate that incomplete reporting of preclinical research is not limited to a few elements of research design, but rather is a broader problem that extends to the reporting of the methods and results. We evaluated 47 preclinical research studies from a systematic review of acute lung injury that use mesenchymal stem cells (MSCs) as a treatment. We operationalized the ARRIVE (Animal Research: Reporting of In Vivo Experiments) reporting guidelines for pre-clinical studies into 109 discrete reporting sub-items and extracted 5,123 data elements. Overall, studies reported less than half (47%) of all sub-items (median 51 items; range 37-64). Across all studies, the Methods Section reported less than half (45%) and the Results Section reported less than a third (29%). There was no association between journal impact factor and completeness of reporting, which suggests that incomplete reporting of preclinical research occurs across all journals regardless of their perceived prestige. Incomplete reporting of methods and results will impede attempts to replicate research findings and maximize the value of preclinical studies.

  4. Using incomplete citation data for MEDLINE results ranking.

    Science.gov (United States)

    Herskovic, Jorge R; Bernstam, Elmer V

    2005-01-01

    Information overload is a significant problem for modern medicine. Searching MEDLINE for common topics often retrieves more relevant documents than users can review. Therefore, we must identify documents that are not only relevant, but also important. Our system ranks articles using citation counts and the PageRank algorithm, incorporating data from the Science Citation Index. However, citation data is usually incomplete. Therefore, we explore the relationship between the quantity of citation information available to the system and the quality of the result ranking. Specifically, we test the ability of citation count and PageRank to identify "important articles" as defined by experts from large result sets with decreasing citation information. We found that PageRank performs better than simple citation counts, but both algorithms are surprisingly robust to information loss. We conclude that even an incomplete citation database is likely to be effective for importance ranking.

  5. Pricing the Option to Surrender in Incomplete Markets

    DEFF Research Database (Denmark)

    Consiglio, Andrea; De Giovanni, Domenico

    New international accounting standards require insurers to reflect the value of embedded options and guarantees in their products. Pricing techniques based on the Black & Scholes paradigm are often used, however, the hypotheses underneath this model are rarely met. We propose a framework that enc......New international accounting standards require insurers to reflect the value of embedded options and guarantees in their products. Pricing techniques based on the Black & Scholes paradigm are often used, however, the hypotheses underneath this model are rarely met. We propose a framework...... that encompasses the most known sources of incompleteness. We show that the surrender option, joined with a wide range of claims embedded in insurance contracts, can be priced through our tool, and deliver hedging portfolios to mitigate the risk arising from their positions. We provide extensive empirical analysis...... to highlight the effect of incompleteness on the fair value of the option....

  6. Ultrasound appearance of knuckle pads

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Ben, R. [Univ. of Alabama, Birmingham (United States). Dept. of Diagnostic Radiology; Dehghanpisheh, K.; Chatham, W.W.; Alarcon, G.S. [Univ. of Alabama, Birmingham (United States). Dept. of Medicine; Lee, D.H.; Oakes, J. [Univ. of Alabama, Birmingham (United States). Dept. of Surgery

    2006-11-15

    We describe the ultrasound appearance of knuckle pads. Retrospective analysis of imaging in a series of five patients initially referred for evaluation of periarticular soft-tissue swelling of the hands involving the dorsum of the PIP and MP joints. Two patients had associated Dupuytren's contractures. Ultrasound and radiographs of the hands in all patients were reviewed and correlated with clinical history and physical exams. Radiographs in four patients demonstrated dorsal soft-tissue thickening. Ultrasound exams showed increased dorsal subcutaneous thickening, with either diffuse or focal hypoechoic areas corresponding to the areas of soft-tissue fullness identified on physical exam. No erosions or synovial proliferation were identified either by radiographs or ultrasound of the underlying joints. Knuckle pads can sometimes be difficult to distinguish from synovitis on physical examination. Musculoskeletal ultrasound can quickly identify these superficial lesions and exclude underlying synovial proliferation.

  7. Diagnostic significance of ultrasound in dermatology

    OpenAIRE

    Stojanović Slobodan; Poljački Mirjana N.; Roš Tatjana

    2002-01-01

    Introduction Utilization of 20 MHz ultrasound probes provided application of ultrasound in dermatology - dermatosonography. As a diagnostic tool, ultrasound was first registered in the early fifties of the past century. Great progress of dermatosonography occurred in the mid-nineties with introduction of the first 20 MHz scanner. Methods of ultrasonography in dermatology Several methods of ultrasonography have been developed: method A, method B, scanning C method and Doppler ultrasound. They ...

  8. [Evaluation of the diagnosis of subclinical endometritis in dairy cattle using ultrasound].

    Science.gov (United States)

    Lenz, Mirjam; Drillich, Marc; Heuwieser, Wolfgang

    2007-01-01

    The aim of this study was to determine signs of subclinical endometritis found by ultrasound that are associated with reduced fertility in dairy cows. The maximum diameter of the uterine lumen was determined by ultrasound in 324 cows without clinical signs of endometritis after evaluation of the genital tract 21 to 27 days postpartum. Cows were classified into healthy or with subclinical endometritis by three threshold values for the maximum uterine lumen diameter of 0.2 cm, 0.5 cm or 0.8 cm. Examinations by rectal palpation and ultrasound as well as classifications were repeated 14 days later. In addition, ovaries were scanned by ultrasound to determine the stage of the estrous cycle. In a subgroup of 103 cows the echotexture of the uterus and its contents was evaluated. In these cows the diagnosis of subclinical endometritis was performed by a scoring system. The diameter of the uterine lumen was significantly affected by stage of the estrous cycle at the time of examination. However, no effects were found for the stage of the cycle at the time of examination on subsequent reproductive performance. A uterine lumen with a maximum diameter of more than 0.2 cm showed a significant negative association with conception rate and proportion of cows pregnant. Classification based on higher threshold values did not reveal an association with reproductive performance. Echogenic content in the uterus also decreased reproductive performance. A classification based on the echotexture of the uterus and its contents revealed significant differences between healthy cows and cows with subclinical endometritis regarding the proportion of cows inseminated and pregnant. The results of this study showed that the diagnostic of bovine endometritis should be broadend by ultrasonography. The definition of subclinical endometritis diagnosed by means of ultrasonography has to be evaluated in further studies.

  9. The effect of smartphone addiction on hand joints in psoriatic patients: an ultrasound-based study.

    Science.gov (United States)

    Megna, M; Gisonni, P; Napolitano, M; Orabona, G Dell'Aversano; Patruno, C; Ayala, F; Balato, N

    2018-01-01

    Distal interphalangeal (DIP) arthritis is a frequent form of psoriatic arthritis being often linked to nail psoriasis. Modern society is characterized by overuse of smartphones. Indeed, literature has recently focalized on research into smartphone addiction and health-related problems. As smartphone addiction is able to determine overuse and repeated movements of DIP joints and nails, the aim of this study was to evaluate the impact of smartphone use on hand joints of young psoriatic patients. An observational study involving four different groups such as non-smartphone-addicted (SA) psoriatic patients, SA psoriatic patients, non-SA controls and SA controls was performed. Each subject underwent an ultrasound examination of both hands by three independent and blinded to group assignment radiologists. A specific score was used to evaluate the inflammatory state of the analysed joints. The total ultrasound score was statistically significantly higher in SA controls respect to non-SA controls (3.4 vs. 1.4; P Smartphone overuse was found to be linked with higher signs of inflammation of musculoskeletal structures of hands joints in both psoriasis and controls through ultrasound examination. Therefore, smartphone overuse may be a factor which facilitate or speed up the possible development of psoriatic arthritis. © 2017 European Academy of Dermatology and Venereology.

  10. Clinical and psychological features of addict people with an incomplete suicide attempt

    Directory of Open Access Journals (Sweden)

    Zhuravlyova T.V.

    2016-01-01

    Full Text Available The article presents results of social, psychological and clinical aspects of suicidal behaviour of alcohol addicts and drug addicts with incomplete suicide attempts, admitted to the Department of crisis states and psychosomatic disorders, Sklifosovsky Research Institute of Ambulance Service from November 2014 to June 2015. The majority of addicts (70% showed an affective kind of suicidal actions. During an acute post-suicidal period all examined patients revealed value-oriented approach to life. Conflict becomes irrelevant as a result of expressed fear of death and fear of social and transcendental consequences of an suicide act. Alcohol addicts feel guilty towards relatives and others, and need of their support. They have significantly increased fear to loss of social identity. Drug addicts have maintained negative view of near and distant future events, they consider the act of suicide as an effective and radical way of solving life problems. Based on our findings we concluded that the risk of repeat suicide attempts in patients with alcohol dependence can be caused by the weakness of self-management skills and lack of microsocial environmental support, while a similar risk in persons with drug addiction can be due to negative view of their own future and the degree of social maladjustment.

  11. Derivatives of the Incomplete Beta Function

    Directory of Open Access Journals (Sweden)

    Robert J. Boik

    1998-03-01

    Full Text Available The incomplete beta function is defined as where Beta(p, q is the beta function. Dutka (1981 gave a history of the development and numerical evaluation of this function. In this article, an algorithm for computing first and second derivatives of Ix,p,q with respect to p and q is described. The algorithm is useful, for example, when fitting parameters to a censored beta, truncated beta, or a truncated beta-binomial model.

  12. Objective and structured assessment of lung ultrasound competence

    DEFF Research Database (Denmark)

    Skaarup, Søren Helbo; Laursen, Christian B.; Bjerrum, Anne Sofie

    2017-01-01

    RATIONALE: Point-of-care lung ultrasound imaging has substantial diagnostic value and is widely used in respiratory, emergency and critical care medicine. Like other ultrasound examinations, lung ultrasound is operator-dependent. The current recommendations for competence in lung ultrasound sets...... a fixed number of ultrasound procedures to be performed without considering different learning rates. Recommendations do not consider different uses of lung ultrasound across specialties. OBJECTIVE: To create a reliable, valid and feasible instrument to assess lung ultrasound competence that includes...... 23 ultrasound operators of different competence levels. Examination time was measured and skill was rated by experienced observers using the assessment tool. Inter-rater agreement was examined by two observers in 9 lung ultrasound examinations. RESULTS: Consensus was obtained within 3 Delphi rounds...

  13. Problem of unstable pivots in the incomplete LU-conjugate gradient method

    International Nuclear Information System (INIS)

    Kershaw, D.S.

    1978-01-01

    Incomplete LU and incomplete-Cholesky conjugate gradient methods are becoming widely used in both laser and magnetic fusion research. In my original presentation of these methods, the problem of what to do if a pivot [L/sub ii/U/sub ii/) becomes very small or zero was raised and only partially answered by the suggestion that it be arbitrarily set to some non-zero value. In what follows it will be shown precisely how small the pivot can become before it must be fixed and precisely what value it should be set to in order to minimize the error in LU. Numerical examples will be given to show that not only does this prescription improve incomplete LU-conjugate gradient methods , but exact LU decomposition carried out with this prescription for handling small pivots and followed by a few linear or conjugate gradient iterations can be much faster than the permutations of rows and columns usually employed to circumvent small pivot problems

  14. On the Pricing of Options in Incomplete Markets

    NARCIS (Netherlands)

    Melenberg, B.; Werker, B.J.M.

    1996-01-01

    In this paper we reconsider the pricing of options in incomplete continuous time markets.We first discuss option pricing with idiosyncratic stochastic volatility.This leads, of course, to an averaged Black-Scholes price formula.Our proof of this result uses a new formalization of idiosyncraticy

  15. Holistic ultrasound in trauma: An update.

    Science.gov (United States)

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Soleus muscle injury: sensitivity of ultrasound patterns

    Energy Technology Data Exchange (ETDEWEB)

    Balius, Ramon [Sport Catalan Council, Generalitat de Catalunya, Barcelona (Spain); Clinica CMI Diagonal, Barcelona (Spain); Rodas, Gil [F.C. Barcelona Medical Services, Barcelona (Spain); Pedret, Carles [Clinica CMI Diagonal, Barcelona (Spain); Clinica Mapfre de Medicina del Tenis, Sports Medicine and Imaging Department, Barcelona (Spain); Centre de Diagnostic per Imatge de Tarragona, Tarragona (Spain); Capdevila, Lluis [Universitat Autonoma de Barcelona, Laboratory of Sport Psychology, Barcelona (Spain); Alomar, Xavier [Clinica Creu Blanca, Barcelona (Spain); Bong, David A. [Instituto Poal de Reumatologia, Barcelona (Spain)

    2014-06-15

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  18. Soleus muscle injury: sensitivity of ultrasound patterns.

    Science.gov (United States)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluís; Alomar, Xavier; Bong, David A

    2014-06-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the "gold standard." In MRI studies, 24 cases (43.7%) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3%) and in the anterior aponeurosis (AMF) in 9 (16.4%). Thirty-one cases (56.3%) were musculotendinous injuries, with 9 cases (16.4%) in the medial aponeurosis (MMT), 11 cases (20%) in the lateral aponeurosis (LMT), and 11 cases (20%) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2% of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area.

  19. Soleus muscle injury: sensitivity of ultrasound patterns

    International Nuclear Information System (INIS)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluis; Alomar, Xavier; Bong, David A.

    2014-01-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  20. Crystallization of glycine with ultrasound

    DEFF Research Database (Denmark)

    Louhi-Kultanen, Marjatta; Karjalainen, Milja; Rantanen, Jukka

    2006-01-01

    Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound with an ultr...... ultrasound power. This study also showed, the higher the ultrasound amplitude the smaller the crystals obtained.......Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound...... with an ultrasound frequency of 20kHz at two temperature ranges 40-50 and 20-30 degrees C in a jacketed 250-ml cooling crystallizer equipped with a stirrer. The polymorph composition of the obtained crystals was analyzed with a temperature variable X-ray powder diffractometer (XRPD). XRPD results showed that...

  1. Ultrasound Imaging of Mouse Fetal Intracranial Hemorrhage Due to Ischemia/Reperfusion

    Directory of Open Access Journals (Sweden)

    Kenichi Funamoto

    2017-05-01

    Full Text Available Despite vast improvement in perinatal care during the 30 years, the incidence rate of neonatal encephalopathy remains unchanged without any further Progress towards preventive strategies for the clinical impasse. Antenatal brain injury including fetal intracranial hemorrhage caused by ischemia/reperfusion is known as one of the primary triggers of neonatal injury. However, the mechanisms of antenatal brain injury are poorly understood unless better predictive models of the disease are developed. Here we show a mouse model for fetal intracranial hemorrhage in vivo developed to investigate the actual timing of hypoxia-ischemic events and their related mechanisms of injury. Intrauterine growth restriction mouse fetuses were exposed to ischemia/reperfusion cycles by occluding and opening the uterine and ovarian arteries in the mother. The presence and timing of fetal intracranial hemorrhage caused by the ischemia/reperfusion were measured with histological observation and ultrasound imaging. Protein-restricted diet increased the risk of fetal intracranial hemorrhage. The monitoring of fetal brains by ultrasound B-mode imaging clarified that cerebral hemorrhage in the fetal brain occurred after the second ischemic period. Three-dimensional ultrasound power Doppler imaging visualized the disappearance of main blood flows in the fetal brain. These indicate a breakdown of cerebrovascular autoregulation which causes the fetal intracranial hemorrhage. This study supports the fact that the ischemia/reperfusion triggers cerebral hemorrhage in the fetal brain. The present method enables us to noninvasively create the cerebral hemorrhage in a fetus without directly touching the body but with repeated occlusion and opening of the uterine and ovarian arteries in the mother.

  2. Experimental validation of incomplete data CT image reconstruction techniques

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Hsiao, M.L.; Tam, K.C.

    1989-01-01

    X-ray CT inspection of large metal parts is often limited by x-ray penetration problems along many of the ray paths required for a complete CT data set. In addition, because of the complex geometry of many industrial parts, manipulation difficulties often prevent scanning over some range of angles. CT images reconstructed from these incomplete data sets contain a variety of artifacts which limit their usefulness in part quality determination. Over the past several years, the authors' company has developed 2 new methods of incorporating a priori information about the parts under inspection to significantly improve incomplete data CT image quality. This work reviews the methods which were developed and presents experimental results which confirm the effectiveness of the techniques. The new methods for dealing with incomplete CT data sets rely on a priori information from part blueprints (in electronic form), outer boundary information from touch sensors, estimates of part outer boundaries from available x-ray data, and linear x-ray attenuation coefficients of the part. The two methods make use of this information in different fashions. The relative performance of the two methods in detecting various flaw types is compared. Methods for accurately registering a priori information with x-ray data are also described. These results are critical to a new industrial x-ray inspection cell built for inspection of large aircraft engine parts

  3. Group prioritisation with unknown expert weights in incomplete linguistic context

    Science.gov (United States)

    Cheng, Dong; Cheng, Faxin; Zhou, Zhili; Wang, Juan

    2017-09-01

    In this paper, we study a group prioritisation problem in situations when the expert weights are completely unknown and their judgement preferences are linguistic and incomplete. Starting from the theory of relative entropy (RE) and multiplicative consistency, an optimisation model is provided for deriving an individual priority vector without estimating the missing value(s) of an incomplete linguistic preference relation. In order to address the unknown expert weights in the group aggregating process, we define two new kinds of expert weight indicators based on RE: proximity entropy weight and similarity entropy weight. Furthermore, a dynamic-adjusting algorithm (DAA) is proposed to obtain an objective expert weight vector and capture the dynamic properties involved in it. Unlike the extant literature of group prioritisation, the proposed RE approach does not require pre-allocation of expert weights and can solve incomplete preference relations. An interesting finding is that once all the experts express their preference relations, the final expert weight vector derived from the DAA is fixed irrespective of the initial settings of expert weights. Finally, an application example is conducted to validate the effectiveness and robustness of the RE approach.

  4. Contractual Efficiency of PPP Infrastructure Projects: An Incomplete Contract Model

    Directory of Open Access Journals (Sweden)

    Lei Shi

    2018-01-01

    Full Text Available This study analyses the contractual efficiency of public-private partnership (PPP infrastructure projects, with a focus on two financial aspects: the nonrecourse principal and incompleteness of debt contracts. The nonrecourse principal releases the sponsoring companies from the debt contract when the special purpose vehicle (SPV established by the sponsoring companies falls into default. Consequently, all obligations under the debt contract are limited to the liability of the SPV following its default. Because the debt contract is incomplete, a renegotiation of an additional loan between the bank and the SPV might occur to enable project continuation or liquidation, which in turn influences the SPV’s ex ante strategies (moral hazard. Considering these two financial features of PPP infrastructure projects, this study develops an incomplete contract model to investigate how the renegotiation triggers ex ante moral hazard and ex post inefficient liquidation. We derive equilibrium strategies under service fees endogenously determined via bidding and examine the effect of equilibrium strategies on contractual efficiency. Finally, we propose an optimal combination of a performance guarantee, the government’s termination right, and a service fee to improve the contractual efficiency of PPP infrastructure projects.

  5. Measurement of compartment elasticity using pressure related ultrasound: a method to identify patients with potential compartment syndrome.

    Science.gov (United States)

    Sellei, R M; Hingmann, S J; Kobbe, P; Weber, C; Grice, J E; Zimmerman, F; Jeromin, S; Gansslen, A; Hildebrand, F; Pape, H C

    2015-01-01

    PURPOSE OF THE STUDY Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. MATERIAL AND METHODS In an in-vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intracompartmental pressures (p) were raised subsequently up to 80 mm Hg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mm Hg) upon the surface resulting in a linear compartmental displacement (Δd). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. RESULTS With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mm Hg) occurred. The Pearson's coefficient showed a high correlation (r2 = -0.960). The intraobserver reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). CONCLUSIONS Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete

  6. Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner.

    Science.gov (United States)

    Long, Zaiyang; Tradup, Donald J; Stekel, Scott F; Gorny, Krzysztof R; Hangiandreou, Nicholas J

    2018-03-01

    We evaluated a commercially available software package that uses B-mode images to semi-automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi-automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1-5), and sector (S1-5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra- and inter-individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above-mentioned image qualities under well-controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Noncontact ultrasound imaging applied to cortical bone phantoms.

    Science.gov (United States)

    Bulman, J B; Ganezer, K S; Halcrow, P W; Neeson, Ian

    2012-06-01

    The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns. A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm(3) and in bone mineral density from 0 to 1.7 g/cm(3). Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of the in vivo range found in cortical bone. A total of 16-20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%-2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%-2%. Transmittance

  8. Hydatidiform moles among patients with incomplete abortion in ...

    African Journals Online (AJOL)

    SHS

    ated risk factors of HM among patients with incomplete abortion evacuated at Bugando Medical ... Konje E, Massinde A, Rambau P. Hydatidiform moles among patients with ... countries (North America, Australia, New Zealand and ... missed as the cause of abortion. .... and duration of cigarette smoking could not be elicited.

  9. Suction v. conventional curettage in incomplete abortion A ...

    African Journals Online (AJOL)

    This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0,0001) and a significantly higher mean ...

  10. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  11. Management of incomplete abortion in South African public hospitals.

    Science.gov (United States)

    Brown, H C; Jewkes, R; Levin, J; Dickson-Tetteh, K; Rees, H

    2003-04-01

    To describe the current management of incomplete abortion in South African public hospitals and to discuss the extent to which management is clinically appropriate. A multicentre, prospective descriptive study. South African public hospitals that manage gynaecological emergencies. Hospitals were selected using a stratified random sampling method. All women who presented to the above sampled hospitals with incomplete abortion during the three week data collection period in 2000 were included. A data collection sheet was completed at the time of discharge for each woman admitted with a diagnosis of incomplete, complete, missed or inevitable abortion during the study period. Information gathered included demographic data, clinical signs and symptoms at admission, medical management, surgical management, anaestetic management, use of blood products and antibiotics and complications. Three clinical severity categories were used for the purpose of data analysis and interpretation. Detail of medical management, detail of surgical management, use of blood products and antibiotics, methods of analgesia and anaesthesia used, and use of abortifacients. There is a trend towards low cost technology such as the use of manual vacuum aspiration and sedation anaesthesia; however, this is mainly limited to the better resourced tertiary hospitals linked to academic units. The use of antibiotics and blood products has decreased but much of the use is inappropriate. The use of abortifacients does include some use of misoprostol but merely as an adjunct to surgical evacuation. The management of incomplete abortion remains a problem in South Africa, a low income country that is still managing a common clinical problem with costly interventions. The evidence of a trend towards low cost technology is promising, albeit limited to tertiary centres. This study has given us information as how to best address this problem. More training in low cost methods is needed, targeting in particular the

  12. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  13. Low-energy nuclear reaction of the 14N+169Tm system: Incomplete fusion

    Science.gov (United States)

    Kumar, R.; Sharma, Vijay R.; Yadav, Abhishek; Singh, Pushpendra P.; Agarwal, Avinash; Appannababu, S.; Mukherjee, S.; Singh, B. P.; Ali, R.; Bhowmik, R. K.

    2017-11-01

    Excitation functions of reaction residues produced in the 14N+169Tm system have been measured to high precision at energies above the fusion barrier, ranging from 1.04 VB to 1.30 VB , and analyzed in the framework of the statistical model code pace4. Analysis of α -emitting channels points toward the onset of incomplete fusion even at slightly above-barrier energies where complete fusion is supposed to be one of the dominant processes. The onset and strength of incomplete fusion have been deduced and studied in terms of various entrance channel parameters. Present results together with the reanalysis of existing data for various projectile-target combinations conclusively suggest strong influence of projectile structure on the onset of incomplete fusion. Also, a strong dependence on the Coulomb effect (ZPZT) has been observed for the present system along with different projectile-target combinations available in the literature. It is concluded that the fraction of incomplete fusion linearly increases with ZPZT and is found to be more for larger ZPZT values, indicating significantly important linear systematics.

  14. Unpowered wireless transmission of ultrasound signals

    International Nuclear Information System (INIS)

    Huang, H; Paramo, D; Deshmukh, S

    2011-01-01

    This paper presents a wireless ultrasound sensing system that uses frequency conversion to convert the ultrasound signal to a microwave signal and transmit it directly without digitization. Constructed from a few passive microwave components, the sensor is able to sense, modulate, and transmit the full waveform of ultrasound signals wirelessly without requiring any local power source. The principle of operation of the unpowered wireless ultrasound sensor is described first, and this is followed by a detailed description of the implementation of the sensor and the sensor interrogation unit using commercially available antennas and microwave components. Validation of the sensing system using an ultrasound pitch–catch system and the power analysis model of the system are also presented

  15. Incomplete nonextensive statistics and the zeroth law of thermodynamics

    International Nuclear Information System (INIS)

    Huang Zhi-Fu; Ou Cong-Jie; Chen Jin-Can

    2013-01-01

    On the basis of the entropy of incomplete statistics (IS) and the joint probability factorization condition, two controversial problems existing in IS are investigated: one is what expression of the internal energy is reasonable for a composite system and the other is whether the traditional zeroth law of thermodynamics is suitable for IS. Some new equivalent expressions of the internal energy of a composite system are derived through accurate mathematical calculation. Moreover, a self-consistent calculation is used to expound that the zeroth law of thermodynamics is also suitable for IS, but it cannot be proven theoretically. Finally, it is pointed out that the generalized zeroth law of thermodynamics for incomplete nonextensive statistics is unnecessary and the nonextensive assumptions for the composite internal energy will lead to mathematical contradiction. (general)

  16. Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit.

    Science.gov (United States)

    Izadifar, Zahra; Belev, George; Babyn, Paul; Chapman, Dean

    2015-10-19

    The observation of ultrasound generated cavitation bubbles deep in tissue is very difficult. The development of an imaging method capable of investigating cavitation bubbles in tissue would improve the efficiency and application of ultrasound in the clinic. Among the previous imaging modalities capable of detecting cavitation bubbles in vivo, the acoustic detection technique has the positive aspect of in vivo application. However the size of the initial cavitation bubble and the amplitude of the ultrasound that produced the cavitation bubbles, affect the timing and amplitude of the cavitation bubbles' emissions. The spatial distribution of cavitation bubbles, driven by 0.8835 MHz therapeutic ultrasound system at output power of 14 Watt, was studied in water using a synchrotron X-ray imaging technique, Analyzer Based Imaging (ABI). The cavitation bubble distribution was investigated by repeated application of the ultrasound and imaging the water tank. The spatial frequency of the cavitation bubble pattern was evaluated by Fourier analysis. Acoustic cavitation was imaged at four different locations through the acoustic beam in water at a fixed power level. The pattern of cavitation bubbles in water was detected by synchrotron X-ray ABI. The spatial distribution of cavitation bubbles driven by the therapeutic ultrasound system was observed using ABI X-ray imaging technique. It was observed that the cavitation bubbles appeared in a periodic pattern. The calculated distance between intervals revealed that the distance of frequent cavitation lines (intervals) is one-half of the acoustic wave length consistent with standing waves. This set of experiments demonstrates the utility of synchrotron ABI for visualizing cavitation bubbles formed in water by clinical ultrasound systems working at high frequency and output powers as low as a therapeutic system.

  17. The Devil Is in the Details: Incomplete Reporting in Preclinical Animal Research.

    Directory of Open Access Journals (Sweden)

    Marc T Avey

    Full Text Available Incomplete reporting of study methods and results has become a focal point for failures in the reproducibility and translation of findings from preclinical research. Here we demonstrate that incomplete reporting of preclinical research is not limited to a few elements of research design, but rather is a broader problem that extends to the reporting of the methods and results. We evaluated 47 preclinical research studies from a systematic review of acute lung injury that use mesenchymal stem cells (MSCs as a treatment. We operationalized the ARRIVE (Animal Research: Reporting of In Vivo Experiments reporting guidelines for pre-clinical studies into 109 discrete reporting sub-items and extracted 5,123 data elements. Overall, studies reported less than half (47% of all sub-items (median 51 items; range 37-64. Across all studies, the Methods Section reported less than half (45% and the Results Section reported less than a third (29%. There was no association between journal impact factor and completeness of reporting, which suggests that incomplete reporting of preclinical research occurs across all journals regardless of their perceived prestige. Incomplete reporting of methods and results will impede attempts to replicate research findings and maximize the value of preclinical studies.

  18. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  19. Adaptive Beamforming for Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund

    This dissertation investigates the application of adaptive beamforming for medical ultrasound imaging. The investigations have been concentrated primarily on the Minimum Variance (MV) beamformer. A broadband implementation of theMV beamformer is described, and simulated data have been used...... to demonstrate the performance. The MV beamformer has been applied to different sets of ultrasound imaging sequences; synthetic aperture ultrasound imaging and plane wave ultrasound imaging. And an approach for applying MV optimized apodization weights on both the transmitting and the receiving apertures...

  20. Ultrasound-induced radical polymerization

    NARCIS (Netherlands)

    Kuijpers, M.W.A.; Kemmere, M.F.; Keurentjes, J.T.F.

    2004-01-01

    Sonochemistry comprises all chemical effects that are induced by ultrasound. Most of these effects are caused by cavitations, ie, the collapse of microscopic bubbles in a liquid. The chemical effects of ultrasound include the formation of radicals and the enhancement of reaction rates at ambient

  1. Sufficient convergency conditions for an implicit class of incomplete factorization circuits

    International Nuclear Information System (INIS)

    Artem'ev, V.K.

    1984-01-01

    The convergence for an implicit class of incomplete factorization circuits with peripheral compensation is theoretically investigated. The convergence theorem is indicated. Sufficiert conditions for the circuit parameters providing the convergence are obtained. The parameters selection may be program-realized, one parameter remaining free. For account of selection of this parameter the method convergence rate may be optimized. Numerical experiments and comparisons with other methods with model problems have shown the efficiency of incomplete factorization circuits. The method is applied for calculating reactors for the solution of hydrodynamic and thermal problems

  2. Reliability of Ultrasound Diameter Measurements in Patients with a Small Asymptomatic Popliteal Artery Aneurysm: An Intra- and Inter-observer Agreement Study.

    Science.gov (United States)

    Zwiers, I; Hoogland, C M T; Mackaay, A J C

    2016-03-01

    In this study the intra- and inter-observer variability of ultrasound measurements of the diameter of the popliteal artery were tested in a group of patients under surveillance for a small (diameter 10-20 mm), asymptomatic popliteal artery aneurysm (PAA). From a group of patients under ultrasound surveillance for bilateral, asymptomatic PAAs, 13 consecutive patients agreed to participate in the study and provided informed consent. The maximum diameter of the popliteal arteries was assessed by a vascular technologist. The same assessment was repeated by a second vascular technologist, unaware of the results of the first measurement. After a week, this protocol was repeated. The intra- and inter-observer reliability of this measurement was calculated using intra-class correlation coefficients (ICCs) and Bland and Altman plots. Of the 10 patients with bilateral and three patients with unilateral PAA, 12 completed the 2 week protocol. A total of 86 measurements were analyzed. The mean diameter of the popliteal arteries was 13.5 ± 3.4 mm. The ICC for the intra-observer reliability of observer 1 was 0.96 (95% CI 0.92-0.99), p .47. The absolute magnitude of the systematic error of both observers was less than 0.135 mm (median 0.00). Ultrasound measurement of the maximum diameter of the popliteal artery is reproducible; hence, it is suitable for making a clinical treatment decision. Its use for surveillance of small, asymptomatic PAAs is justified. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Mirizzi Syndrome with Endoscopic Ultrasound Image

    Directory of Open Access Journals (Sweden)

    K. Rayapudi

    2013-05-01

    Full Text Available We describe a 66-year-old Caucasian man with type 1 Mirizzi syndrome diagnosed on endoscopic ultrasound. He presented with acute onset of jaundice, malaise, dark urine over 3-4 days, and was found to have obstructive jaundice on lab testing. CT scan of the abdomen showed intrahepatic biliary ductal dilation, a 1.5 cm common bile duct (CBD above the pancreas, and possible stones in the CBD, but no masses. Endoscopic retrograde cholangiopancreatography (ERCP by a community gastroenterologist failed to cannulate the CBD. At the University Center, type 1 Mirizzi syndrome was noted on endoscopic ultrasound with narrowing of the CBD with extrinsic compression from cystic duct stone. During repeat ERCP, the CBD could be cannulated over the pancreatic duct wire. A mid CBD narrowing, distal CBD stones, proximal CBD and extrahepatic duct dilation were noted, and biliary sphincterotomy was performed. A small stone in the distal CBD was removed with an extraction balloon. The cystic duct stone was moved with the biliary balloon into the CBD, mechanical basket lithotripsy was performed and stone fragments were delivered out with an extraction balloon. The patient was seen 7 weeks later in the clinic. Skin and scleral icterus had cleared up and he is scheduled for an elective cholecystectomy. Mirizzi syndrome refers to biliary obstruction resulting from impacted stone in the cystic duct or neck of the gallbladder and commonly presents with obstructive jaundice. Type 1 does not have cholecystocholedochal fistulas, but they present in types 2, 3 and 4. Surgery is the mainstay of therapy. Endoscopic treatment is effective and can also be used as a temporizing measure or definitive treatment in poor surgical risk candidates.

  4. Screening esophagus during routine ultrasound: medical and cost benefits.

    Science.gov (United States)

    Abd Elrazek, Abd Elrazek M A; Eid, Khaled A; El-Sherif, Abd Elhalim A; Abd El Al, Usama M; El-Sherbiny, Samir M; Bilasy, Shymaa E

    2015-01-01

    Cost-effectiveness analysis is an approach used to determine the value of a medical care option and refers to a method used to assess the costs and health benefits of an intervention. Upon the diagnosis of liver cirrhosis, the current guidelines recommend that all cirrhotic patients have to be screened for the presence of esophageal varices by endoscopy. In addition, patients with a positive family history of esophageal cancer are screened annually. These approaches place a heavy burden on endoscopy units, and repeated testing over time may have a detrimental effect on patient compliance. Following the recommendations of a recent study entitled 'Detection of risky esophageal varices using two dimensional ultrasound: when to perform endoscopy', the intra-abdominal portion of the esophagus of 1100 patients was divided into a hepatic group, which included 650 patients, and a nonhepatic group, which included 450 patients, who presented with manifestations of liver diseases and gastrointestinal symptoms, respectively, and were examined using standard two-dimensional ultrasound (US) to evaluate cost effectiveness, standard issues, and medical benefits using conventional US. The overall effectiveness analysis of 1100 patients yielded a 41% cost standard benefit calculated to be $114,760 in a 6-month study. Two-dimensional US can play an important role in screening for esophageal abnormalities, thus saving money and time. The esophagus should be screened during routine conventional abdominal US.

  5. Hearing loss in enlarged vestibular aqueduct and incomplete partition type II.

    Science.gov (United States)

    Ahadizadeh, Emily; Ascha, Mustafa; Manzoor, Nauman; Gupta, Amit; Semaan, Maroun; Megerian, Cliff; Otteson, Todd

    The purpose of this work is to identify the role of incomplete partition type II on hearing loss among patients with enlarged vestibular aqueduct (EVA). EVA is a common congenital inner ear malformation among children with hearing loss, where vestibular aqueduct morphology in this population has been shown to correlate to hearing loss. However, the impact of incomplete partition between cochlear turns on hearing loss has not been, despite meaningful implications for EVA pathophysiology. A retrospective review of radiology reports for patients who had computed tomography (CT) scans with diagnoses of hearing loss at a tertiary medical center between January 2000 and June 2016 were screened for EVA. CT scans of the internal auditory canal (IAC) for those patients with EVA were examined for evidence of incomplete partition type II (IP-II), measurements of midpoint width and operculum width a second time, and patients meeting Cincinnati criteria for EVA selected for analysis. Statistical analysis including chi-square, Wilcoxon rank-sum, and t-tests were used to identify differences in outcomes and clinical predictors, as appropriate for the distribution of the data. Linear mixed models of hearing test results for all available tests were constructed, both univariable and adjusting for vestibular aqueduct morphometric features, with ear-specific intercepts and slopes over time. There were no statistically significant differences in any hearing test results or vestibular aqueduct midpoint and operculum widths. Linear mixed models, both univariable and those adjusting for midpoint and operculum widths, did not indicate a statistically significant effect of incomplete partition type II on hearing test results. Hearing loss due to enlarged vestibular aqueduct does not appear to be affected by the presence of incomplete partition type II. Our results suggest that the pathophysiological processes underlying hearing loss in enlarged vestibular aqueduct may not be a result of

  6. Performance of chest ultrasound in pediatric pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Claes, Anne-Sophie, E-mail: anso.claes@gmail.com [Departement of Radiology, Pediatric and Thoracic Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Clapuyt, Philippe, E-mail: philippe.clapuyt@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Menten, Renaud, E-mail: renaud.menten@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Michoux, Nicolas, E-mail: nicolas.michoux@uclouvain.be [Departement of Radiology, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Dumitriu, Dana, E-mail: dana.dumitriu@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2017-03-15

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  7. Performance of chest ultrasound in pediatric pneumonia

    International Nuclear Information System (INIS)

    Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana

    2017-01-01

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  8. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  9. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  10. Building Chaotic Model From Incomplete Time Series

    Science.gov (United States)

    Siek, Michael; Solomatine, Dimitri

    2010-05-01

    This paper presents a number of novel techniques for building a predictive chaotic model from incomplete time series. A predictive chaotic model is built by reconstructing the time-delayed phase space from observed time series and the prediction is made by a global model or adaptive local models based on the dynamical neighbors found in the reconstructed phase space. In general, the building of any data-driven models depends on the completeness and quality of the data itself. However, the completeness of the data availability can not always be guaranteed since the measurement or data transmission is intermittently not working properly due to some reasons. We propose two main solutions dealing with incomplete time series: using imputing and non-imputing methods. For imputing methods, we utilized the interpolation methods (weighted sum of linear interpolations, Bayesian principle component analysis and cubic spline interpolation) and predictive models (neural network, kernel machine, chaotic model) for estimating the missing values. After imputing the missing values, the phase space reconstruction and chaotic model prediction are executed as a standard procedure. For non-imputing methods, we reconstructed the time-delayed phase space from observed time series with missing values. This reconstruction results in non-continuous trajectories. However, the local model prediction can still be made from the other dynamical neighbors reconstructed from non-missing values. We implemented and tested these methods to construct a chaotic model for predicting storm surges at Hoek van Holland as the entrance of Rotterdam Port. The hourly surge time series is available for duration of 1990-1996. For measuring the performance of the proposed methods, a synthetic time series with missing values generated by a particular random variable to the original (complete) time series is utilized. There exist two main performance measures used in this work: (1) error measures between the actual

  11. Essays on incomplete contracts in regulatory activities

    Science.gov (United States)

    Saavedra, Eduardo Humberto

    This dissertation consists of three essays. The first essay, The Hold-Up Problem in Public Infrastructure Franchising, characterizes the equilibria of the investment decisions in public infrastructure franchising under incomplete contracting and ex-post renegotiation. The parties (government and a firm) are unable to credibly commit to the contracted investment plan, so that a second step investment is renegotiated by the parties at the revision stage. As expected, the possibility of renegotiation affects initial non-verifiable investments. The main conclusion of this essay is that not only underinvestment but also overinvestment in infrastructure may arise in equilibrium, compared to the complete contracting case. The second essay, Alternative Institutional Arrangements in Network Utilities: An Incomplete Contracting Approach, presents a theoretical assessment of the efficiency implications of privatizing natural monopolies which are vertically related to potential competitive firms. Based on the incomplete contracts and asymmetric information paradigm. I develop a model that analyzes the relative advantages of different institutional arrangements---alternative ownership and market structures in the industry--- in terms of their allocative and productive efficiencies. The main policy conclusion of this essay is that both ownership and the existence of conglomerates in network industries matter. Among other conclusions, this essay provides an economic rationale for a mixed economy in which the network is public and vertical separation of the industry when the natural monopoly is under private ownership. The last essay, Opportunistic Behavior and Legal Disputes in the Chilean Electricity Sector, analyzes post-contractual disputes in this newly privatized industry. It discusses the presumption that opportunistic behavior and disputes arise due to inadequate market design, ambiguous regulation, and institutional weaknesses. This chapter also assesses the presumption

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  13. Sudan and South Sudan's bitter and incomplete divorce

    African Journals Online (AJOL)

    Sudan and South Sudan's bitter and incomplete divorce. Copnall, James 2017. London, Hurst Publishers, 317 pp. ISBN 978-184804-830-9. Reviewed by Nicodemus Minde*. Having served as the BBC Sudan correspondent from 2009 to 2012, James. Copnall has compiled an insightful account of the bitter-sweet split of the.

  14. The capacitated team orienteering problem with incomplete service

    NARCIS (Netherlands)

    Archetti, Claudia; Bianchessi, Nicola; Speranza, M. Grazia

    2013-01-01

    In this paper we study the capacitated version of the Team Orienteering Problem (TOP), that is the Capacitated TOP (CTOP) and the impact of relaxing the assumption that a customer, if served, must be completely served. We prove that the profit collected by the CTOP with Incomplete Service (CTOP-IS)

  15. The Importance of Structure in Incomplete Factorization Preconditioners

    Czech Academy of Sciences Publication Activity Database

    Scott, J.; Tůma, Miroslav

    2011-01-01

    Roč. 51, č. 2 (2011), s. 385-404 ISSN 0006-3835 Grant - others:GA AV ČR(CZ) M100300902 Institutional research plan: CEZ:AV0Z10300504 Keywords : sparse symmetric linear systems * incomplete factorizations * preconditioners * level-based approach Subject RIV: BA - General Mathematics Impact factor: 0.724, year: 2011

  16. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  17. Effect of low-frequency low-intensity ultrasound with microbubbles on prostate cancer hypoxia.

    Science.gov (United States)

    Hou, Rui; Xu, Yanjun; Lu, Qijie; Zhang, Yang; Hu, Bing

    2017-10-01

    Angiogenesis plays an important role in tumor growth, invasiveness, and metastasis. It is well established that prostate cancer is exposed to fluctuating oxygen tensions and both acute and chronic hypoxia exist, and these conditions can upregulate angiogenesis-associated proteins such as hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A. Low-frequency low-intensity ultrasound with microbubbles can induce obvious microvessel damage in tumors, cause cell necrosis or apoptosis. However, there is no information about whether the blocking blood effect of low-frequency low-intensity ultrasound with microbubbles has an influence on hypoxia environment of prostate cancer. Therefore, we investigated the impact of different low-frequency low-intensity ultrasound with microbubbles radiation times on prostate tumors, observed the change in the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A protein levels, as well as cell proliferation, apoptosis, and tumor volume. The results indicated that as the radiation was repeated four times on each treatment day, the effects of interruption were durable, the cell proliferation was inhibited, and apoptosis was promoted, and the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A expression levels were lower in the treatment group than in the control group. When the radiation was carried out once per treatment day, the hypoxia response was stimulated, the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A expression levels were higher compared with the control group, and cell proliferation was promoted. In addition, the tumor volume increased obviously in the hypoxia-stimulated group, whereas tumors grew slowly in the hypoxia-suppressed group. The results of this work demonstrated that under the same conditions, different radiation times of low-frequency low-intensity ultrasound with microbubbles affect the hypoxia response differently, and the

  18. Ultrasound assessment of selected peripheral nerve pathologies. Part III: Injuries and postoperative evaluation

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2013-03-01

    Full Text Available The previous articles of the series devoted to ultrasound diagnostics of peripheral nerves concerned the most common nerve pathologies, i.e. entrapment neuropathies. The aim of the last part of the series is to present ultrasound possibilities in the postoperative control of the peripheral nerves as well as in the diagnostics of the second most common neuropathies of peripheral nerves, i.e. posttraumatic lesions. Early diagnostics of posttraumatic changes is of fundamental importance for the course of treatment and its long-term effects. It aids surgeons in making treatment decisions (whether surgical or conservative. When surgical treatment is necessary, the surgeon, based on US findings, is able to plan a given type of operative method. In certain cases, may even abandon the corrective or reconstructive surgery of the nerve trunk (when there are extensive defects of the nerve trunks and instead, proceed with muscle transfers. Medical literature proposes a range of divisions of the kinds of peripheral nerve injuries depending on, among others, the mechanism or degree of damage. However, the most important issue in the surgeon-diagnostician communication is a detailed description of stumps of the nerve trunks, their distance and location. In the postoperative period, ultrasound is used for monitoring the operative or conservative treatment effects including the determination of the causes of a persistent or recurrent neuropathy. It facilitates decision-making concerning a repeated surgical procedure or assuming a wait-and-see attitude. It is a difficult task for a diagnostician and it requires experience, close cooperation with a clinician and knowledge concerning surgical techniques. Apart from a static assessment, a dynamic assessment of possible adhesions constitutes a crucial element of postoperative examination. This feature distinguishes ultrasound scanning from other methods used in the diagnostics of peripheral neuropathies.

  19. Crime event 3D reconstruction based on incomplete or fragmentary evidence material--case report.

    Science.gov (United States)

    Maksymowicz, Krzysztof; Tunikowski, Wojciech; Kościuk, Jacek

    2014-09-01

    Using our own experience in 3D analysis, the authors will demonstrate the possibilities of 3D crime scene and event reconstruction in cases where originally collected material evidence is largely insufficient. The necessity to repeat forensic evaluation is often down to the emergence of new facts in the course of case proceedings. Even in cases when a crime scene and its surroundings have undergone partial or complete transformation, with regard to elements significant to the course of the case, or when the scene was not satisfactorily secured, it is still possible to reconstruct it in a 3D environment based on the originally-collected, even incomplete, material evidence. In particular cases when no image of the crime scene is available, its partial or even full reconstruction is still potentially feasible. Credibility of evidence for such reconstruction can still satisfy the evidence requirements in court. Reconstruction of the missing elements of the crime scene is still possible with the use of information obtained from current publicly available databases. In the study, we demonstrate that these can include Google Maps(®*), Google Street View(®*) and available construction and architecture archives. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging produces pictures of the internal organs and blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ...

  1. Incomplete (bending) fractures of the mandibular condyle in children

    International Nuclear Information System (INIS)

    Ahrendt, D.; Swischuk, L.E.; Hayden, C.K. Jr.; Texas Univ., Galveston

    1984-01-01

    Incomplete, bending or bowing fractures of the mandibular condyle in children frequently go undetected. The reason is that the bending deformity often is subtle and passes for normal. This is especially true if the fractures are bilateral. (orig.)

  2. Management of incomplete abortions at South African public hospitals

    African Journals Online (AJOL)

    incomplete abortion can be more effectively and safely managed using ..... rational prescribing of antibiotics, use of blood transfusion and shortening ... emotional volcano. ... Sal FT, NaSS1m J. The need lOT a replOOuctrve health approach.

  3. Comparison of ultrasound and ultrasound plus nerve stimulator guidance axillary plexus block

    International Nuclear Information System (INIS)

    Demirelli, G.; Baskan, S.; Karabeyoglu, I.; Aytac, I.; Omek, D.H.; Erdogmus, A.; Baydar, M.

    2017-01-01

    To evaluate the characteristics of axillary plexus blockade applied using ultrasound only and using ultrasound together with nerve stimulator in patients undergoing planned forearm, wrist or hand surgery. Methods: This randomised, prospective, double-blinded, single-centre study was conducted at Ankara Numune Training and Research Hospital, Ankara, Turkey, from November 2014 to August 2015, and comprised patients undergoing forearm, wrist or hand surgery. Participants were separated into 2 groups. In Group 1, the nerve roots required for the surgical site were located one by one and local anaesthetic was applied separately to each nerve for the block. In Group 2, the vascular nerve bundle was located under ultrasound guidance and a total block was achieved by administering all the local anaesthetic within the nerve sheath. In the operating room, standard monitorisation was applied. Following preparation of the skin, the axillary region nerve roots and branches and vascular structures were observed by examination with a high-frequency ultrasound probe. In both groups, a 22-gauge, 5cm block needle was entered to the axillary region with visualisation of the whole needle on ultrasound and 20ml local anaesthetic of 0.5% bupivacaine was injected. SPSS 19 was used for data analysis. Results: Of the 60 participants, there were 30(50%) in each group. The mean age was 39.1+-15 years in the group 1 which was the ultrasound nerve stimulation group, and 41.5+-14.3 years in group 2. The duration of the procedure was longer in group I than in group 2 (p<0.05). Patient satisfaction values during the procedure were higher in group 2(p<0.05). In the ulnar sensory examination, the values of the patients in group 1 were higher at 10, 15, 20 and 25 minutes (p<0.05). In the median, radial and ulnar motor examination, the values of the patients in group 1were higher at 15 and 20 minutes (p<0.05). Conclusion: Brachial plexus blockade via axillary approach guided by ultrasound offered

  4. Splenic abnormalities: a comparative review of ultrasound, microbubble-enhanced ultrasound and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Peddu, P.; Shah, M.; Sidhu, P.S. E-mail: paul.sidhu@kingsch.nhs.uk

    2004-09-01

    The ultrasound appearances of abnormalities of the spleen are reviewed and images compared with computed tomography. Focal lesions, both benign and malignant, trauma, infarction and congenital abnormalities are presented. The use of microbubble ultrasound contrast media as an aid to identifying and characterizing abnormalities is discussed.

  5. Assessment of colonic disease by multi-slice CT pneumocolon after incomplete colonoscopy

    International Nuclear Information System (INIS)

    Zhao Zehua; Liu Wenjin; Xu Songsen; Wang Kang; Wang Weizhong

    2004-01-01

    Objective: To evaluate the use of preoperative MSCT in patients with clinically suspected colorectal disease after incomplete colonoscopy. Methods: After incomplete colonoscopy, 31 patients underwent MSCT before and after intravenous injection of iodinated contrast agent. CT virtual colonography (CTVC), multiplanar reformation (MPR), shaded surface display (SSD), and Raysum images were obtained by using 4 different software in workstation. The results of MSCT were compared with the findings of colonoscopy, intraoperative colon palpation, and postoperative pathology. Results: After incomplete colonoscopy, MSCT was successfully performed in all 31 cases. Postoperative pathology revealed 22 colorectal cancers (one synchronous cancers, two with polyps) and 9 benign disease. 22 colonic carcinomas were all correctly diagnosed by MSCT (including synchronous disease), 2 benign diseases were misdiagnosed as malignancy, and one polyp was missed. Conclusion: MSCT is a feasible and useful method for evaluating the entire colon before surgery in patients with occlusive disease. (author)

  6. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  7. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs...... beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach...... that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation...

  8. All-optical extravascular laser-ultrasound and photoacoustic imaging of calcified atherosclerotic plaque in excised carotid artery

    Directory of Open Access Journals (Sweden)

    Jami L. Johnson

    2018-03-01

    Full Text Available Photoacoustic (PA imaging may be advantageous as a safe, non-invasive imaging modality to image the carotid artery. However, calcification that accompanies atherosclerotic plaque is difficult to detect with PA due to the non-distinct optical absorption spectrum of hydroxyapatite. We propose reflection-mode all-optical laser-ultrasound (LUS imaging to obtain high-resolution, non-contact, non-ionizing images of the carotid artery wall and calcification. All-optical LUS allows for flexible acquisition geometry and user-dependent data acquisition for high repeatability. We apply all-optical techniques to image an excised human carotid artery. Internal layers of the artery wall, enlargement of the vessel, and calcification are observed with higher resolution and reduced artifacts with nonconfocal LUS compared to confocal LUS. Validation with histology and X-ray computed tomography (CT demonstrates the potential for LUS as a method for non-invasive imaging in the carotid artery. Keywords: Atherosclerosis, Photoacoustic imaging, Laser-ultrasound, Calcification, Reverse-time migration

  9. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    Science.gov (United States)

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  10. Spectroscopic study of 126I via incomplete fusion reaction

    International Nuclear Information System (INIS)

    Kanagalekar, B.A.; Das, Pragya; Kumar, Vinod; Kumar, R.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2006-01-01

    The experiment at Inter University Accelerator Centre consisted of identifying the yrast high-spin states of 126 I using the incomplete fusion reaction 124 Sn ( 10 B, α4n) 126 I at beam energy of 70 MeV

  11. Ultrasound: Bladder (For Parents)

    Science.gov (United States)

    ... If You Have Questions Print en español Ultrasonido: vejiga What It Is A bladder ultrasound is a safe and painless test that ... Exam: Voiding Cystourethrogram (VCUG) Ultrasound: Renal (Kidneys, Ureters, Bladder) Urinary ... only. For specific medical advice, diagnoses, and treatment, consult your doctor. © 1995- The Nemours Foundation. All ...

  12. Corruption in PPPs, Incentives and Contract Incompleteness

    OpenAIRE

    Elisabetta Iossa; David Martimort

    2014-01-01

    In a public procurement setting, we discuss the desirability of completing contracts with state-contingent clauses providing for monetary compensations to the contractor when revenue shocks occur. Realized shocks are private information of the contractor and this creates agency costs of delegated service provision. Verifying the contractor’s messages on the shocks entails contracting costs that make incomplete contracts attractive, despite their higher agency costs. A public official (supervi...

  13. Induction of complete and incomplete chromosome aberrations by bleomycin in human lymphocytes

    International Nuclear Information System (INIS)

    Benkhaled, L.; Xuncla, M.; Caballin, M.R.; Barrios, L.; Barquinero, J.F.

    2008-01-01

    Bleomycin (BLM) is a clastogenic compound, which due to the overdispersion in the cell distribution of induced dicentrics has been compared to the effect of high-LET radiation. Recently, it has been described that in fibroblast derived cell lines BLM induces incomplete chromosome elements more efficiently than any type of ionizing radiation. The objective of the present study was to evaluate in human lymphocytes the induction of dicentrics and incomplete chromosome elements by BLM. Peripheral blood samples have been treated with different concentrations of BLM. Two cytogenetic techniques were applied, fluorescence plus Giemsa (FPG) and FISH using pan-centromeric and pan-telomeric probes. The observed frequency of dicentric equivalents increases linearly with the BLM concentration, and for all BLM concentrations the distribution of dicentric equivalents was overdispersed. In the FISH study the ratio between total incomplete elements and multicentrics was 0.27. The overdispersion in the dicentric cell distribution, and the linear BLM-concentration dependence of dicentrics can be compared to the effect of high-LET radiation, on the contrary the ratio of incomplete elements and multicentrics is similar to the one induced by low-LET radiation (∼0.40). The elevated proportion of interstitial deletions in relation to total acentric fragments, higher than any type of ionizing radiation could be a characteristic signature of the clastogenic effect of BLM

  14. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  15. Measurement of tissue viscoelasticity with ultrasound

    Science.gov (United States)

    Greenleaf, J. F.; Alizad, A.

    2017-02-01

    Tissue properties such as elasticity and viscosity have been shown to be related to such tissue conditions as contraction, edema, fibrosis, and fat content among others. Magnetic Resonance Elastography has shown outstanding ability to measure the elasticity and in some cases the viscosity of tissues, especially in the liver, providing the ability to stage fibrotic liver disease similarly to biopsy. We discuss ultrasound methods of measuring elasticity and viscosity in tissues. Many of these methods are becoming widely available in the extant ultrasound machines distributed throughout the world. Some of the methods to be discussed are in the developmental stage. The advantages of the ultrasound methods are that the imaging instruments are widely available and that many of the viscoelastic measurements can be made during a short addition to the normal ultrasound examination time. In addition, the measurements can be made by ultrasound repetitively and quickly allowing evaluation of dynamic physiologic function in circumstances such as muscle contraction or artery relaxation. Measurement of viscoelastic tissue mechanical properties will become a consistent part of clinical ultrasound examinations in our opinion.

  16. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  17. [Role of ultrasound in elective abortions].

    Science.gov (United States)

    Wylomanski, S; Winer, N

    2016-12-01

    Ultrasound plays a fundamental role in the management of elective abortions. Although it can improve the quality of post-abortion care, it must not be an obstacle to abortion access. We thus studied the role of ultrasound in pregnancy dating and possible alternatives and analyzed the literature to determine the role of ultrasound in post-abortion follow-up. During an ultrasound scan, the date of conception is estimated by measurement of the crown-rump length (CRL), defined by Robinson, or of the biparietal diameter (BPD), as defined by the French Center for Fetal Ultrasound (CFEF) after 11 weeks of gestation (Robinson and CFEF curves) (grade B). Updated curves have been developed in the INTERGROWTH study. In the context of abortion, the literature recommends the application of a safety margin of 5 days, especially when the CRL and/or BPD measurement indicates a term close to 14 weeks (that is equal or below 80 and 27mm, respectively) (best practice agreement). Accordingly, with the ultrasound measurement reliable to±5 days when its performance meets the relevant criteria, an abortion can take place when the CRL measurement is less than 90mm or the BPD less than 30mm (INTERGROWTH curves) (best practice agreement). While a dating ultrasound should be encouraged, its absence is not an obstacle to scheduling an abortion for women who report that they know the date of their last menstrual period and/or of the at-risk sexual relations and for whom a clinical examination by a healthcare professional is possible (best practice agreement). In cases of intrauterine pregnancy of uncertain viability or of a pregnancy of unknown location, without any particular symptoms, the patient must be able to have a transvaginal ultrasound to increase the precision of the diagnosis (grade B). Various reviews of the literature on post-abortion follow-up indicate that the routine use of ultrasound during instrumental abortions should be avoided (best practice agreement). If it becomes

  18. Studies of nonlinear ultrasound propagation: safety considerations in the use of ultrasound for medical diagnosis - nonlinear propagation

    International Nuclear Information System (INIS)

    Egerton, B.; Barnett, S.; Vella, G.

    1994-01-01

    Diagnostic ultrasound is an established imaging modality without any documented harmful effects. New developments such as pulsed Doppler and intracavity investigations may result in increases in ultrasound exposures which could cause harm. Thermal mechanisms and cavitation may become relevant sources of bioeffects. The preliminary study described here investigates the distribution and amplitude of harmonics generated through nonlinear propagation of ultrasound in water. Knowledge of harmonic attenuation will help predict sites of enhanced heating and enable accurate modelling of clinical situations. This presentation is concerned with thermal safety guidelines, their relationship to a typical ultrasound beam profile for a single, medium focussed, transducer operating in water and possible sites of enhanced heating due to nonlinear propagation effects. Measurements were made of the amplitudes of the harmonics generated by the nonlinear propagation of ultrasound in water. The amplitudes of the harmonics were detected up to frequencies of 35 MHz and displayed using Fast Fourier Transform facilities within the oscilloscope. The nonlinearity parameter of the ultrasonic waveforms has been identified as an important factor in thermal effects of ultrasound interactions. The appearance of nonlinear distortion is shown to be dependant on the peak compressional pressure and distance from the ultrasound source. 20 refs., 2 figs

  19. Introducing Misoprostol for the Treatment of Incomplete Abortion in ...

    African Journals Online (AJOL)

    Despite legal restriction, induced abortions and resulting complications are common in Nigeria. Misoprostol administration for incomplete abortion was introduced in 3 Nigerian hospitals. The feasibility of the hospitals, patient and provider acceptability were assessed using questionnaire and interview guides administered ...

  20. Consumption-Portfolio Optimization with Recursive Utility in Incomplete Markets

    DEFF Research Database (Denmark)

    Kraft, Holger; Seifried, Frank Thomas; Steffensen, Mogens

    2013-01-01

    In an incomplete market, we study the optimal consumption-portfolio decision of an investor with recursive preferences of Epstein–Zin type. Applying a classical dynamic programming approach, we formulate the associated Hamilton–Jacobi–Bellman equation and provide a suitable verification theorem...

  1. Analysis of α-particle induced incomplete chromosome aberrations, using pan-centro metric and pan-telomeric DNA probes

    International Nuclear Information System (INIS)

    Mestres, M.; Schmid, E.; Stephan, G.; Barrios, L.; Caballin, M. R.; Barquinero, J. F.

    2004-01-01

    The aim of the present study has been the evaluation of the incompleteness of α-particle induced chromosome aberrations by the simultaneous detection of all centromeres and telomeres present in human lymphocytes. For this purpose attached lymphocytes were irradiated at doses of 0.2, 0.5,0.7 and 1 Gy in a ''241Am source. FISH techniques were applied using pan-centromeric and pan-telomeric probes. All abnormal cells were digitalised and analysed using a Cytovision FISH workstation. A total of 378 incomplete chromosomes plus incomplete acentrics was found. Cases with more than 92 telomeres were not detected. The ratio between total incomplete elements and multicentrics was 1.00. The total number of acentric fragments was 822; 57% of then were complete fragments ace (+.+), 26% incomplete fragments ace (+,-), and 17% interstitial fragment ace (-.-). The percentage of incomplete aberrations is higher after high-LET than described for low-LET exposure. The results seem to indicate that compared to low-LET. after α-particle exposure it is more likely to repair the centromere-containing elements. (Author) 30 refs

  2. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  3. What Is the Rate of Incomplete Fetal Anatomic Surveys During a Second-Trimester Scan? Retrospective Observational Study of 4000 Nonobese Pregnant Women.

    Science.gov (United States)

    Padula, Francesco; Gulino, Ferdinando Antonio; Capriglione, Stella; Giorlandino, Maurizio; Cignini, Pietro; Mastrandrea, Maria Luisa; D'Emidio, Laura; Giorlandino, Claudio

    2015-12-01

    The purpose of this study was to estimate the rate of incomplete fetal anatomic surveys during a second-trimester scan due to an unfavorable fetal position in a nonobese population. All pregnant women who came to the Altamedica Fetal-Maternal Medical Center, a specialized center for prenatal diagnosis, for a routine second-trimester scan between January 2012 and April 2013 were retrospectively included in the analysis. Patients with a body mass index higher than 30.0 kg/m(2) or anterior fibroids larger than 5 cm were not included in the study. Of 4000 pregnant women admitted for a second-trimester scan, 169 (4.2%) came back within 2 weeks to complete the examination because of an unfavorable fetal position. In particular, 104 (2.6%) needed visualization of only 1 view, and 65 (1.6%) needed more than 1 view. The most difficult organ to visualize was the corpus callosum, in 73 cases (1.8%); the face was not visualized in 69 cases (1.7%); the cerebellar vermis was not seen in 47 fetuses (1.1%); and the heart could not be completely examined in 40 fetuses (1.0%). Of the 4000 women, 169 (4.2%) had a nonexhaustive scan; 149 (3.7%) needed a second scan to complete the second-trimester survey; 14 (0.35%) needed a third scan; and 2 (0.05%) remained with a not completely exhaustive scan. There is always a small percentage of incomplete fetal anatomic surveys during a second-trimester scan, which cannot be modified by the sonographer's skill or by technical sonographic innovations. © 2015 by the American Institute of Ultrasound in Medicine.

  4. The use of real time ultrasound scanning as a teaching method of anatomy in an undergraduate sonography and medical imaging degree in an Australian university

    International Nuclear Information System (INIS)

    Bowman, A.; Lawson, C.; McKillup, S.

    2016-01-01

    Background: Real-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections. Aim: To assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods medical imaging and sonography students consider effective for understanding human anatomy. Method: Surveys were distributed to two consecutive cohorts of first year medical imaging and medical sonography students at CQUniversity. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA. Results: Real-time ultrasound scanning was the most preferred method of delivery for anatomy classes overall especially compared to computer programs, videos, 3-D radiological images and dissection. Specifically, students indicated that ultrasound scanning was the preferred method to encourage learning from experience (F 7,231  = 2.942, p = 0.006), to develop team skills (F 7,231  = 4.550, p < 0.006), to follow complex instructions (F 7,231  = 4.656 p < 0.001) and to appreciate anatomical variation (F 7,231  = 2.067, p = 0.048). Dissection was the least favoured teaching method. Conclusion: Real-time ultrasound scanning is a useful tool for teaching anatomy, and animal dissections are a poor substitute for the use of human cadavers. - Highlights: • Real-time ultrasound scanning is a valid teaching tool for human anatomy. • Real-time ultrasound is preferred by students compared to other teaching methods. • Dissection is the least favoured method to learn anatomy. • Ultrasound encourages learning from experience and develops team skills.

  5. Blink rate, incomplete blinks and computer vision syndrome.

    Science.gov (United States)

    Portello, Joan K; Rosenfield, Mark; Chu, Christina A

    2013-05-01

    Computer vision syndrome (CVS), a highly prevalent condition, is frequently associated with dry eye disorders. Furthermore, a reduced blink rate has been observed during computer use. The present study examined whether post task ocular and visual symptoms are associated with either a decreased blink rate or a higher prevalence of incomplete blinks. An additional trial tested whether increasing the blink rate would reduce CVS symptoms. Subjects (N = 21) were required to perform a continuous 15-minute reading task on a desktop computer at a viewing distance of 50 cm. Subjects were videotaped during the task to determine their blink rate and amplitude. Immediately after the task, subjects completed a questionnaire regarding ocular symptoms experienced during the trial. In a second session, the blink rate was increased by means of an audible tone that sounded every 4 seconds, with subjects being instructed to blink on hearing the tone. The mean blink rate during the task without the audible tone was 11.6 blinks per minute (SD, 7.84). The percentage of blinks deemed incomplete for each subject ranged from 0.9 to 56.5%, with a mean of 16.1% (SD, 15.7). A significant positive correlation was observed between the total symptom score and the percentage of incomplete blinks during the task (p = 0.002). Furthermore, a significant negative correlation was noted between the blink score and symptoms (p = 0.035). Increasing the mean blink rate to 23.5 blinks per minute by means of the audible tone did not produce a significant change in the symptom score. Whereas CVS symptoms are associated with a reduced blink rate, the completeness of the blink may be equally significant. Because instructing a patient to increase his or her blink rate may be ineffective or impractical, actions to achieve complete corneal coverage during blinking may be more helpful in alleviating symptoms during computer operation.

  6. A Clinical Study on Management of Incomplete Abortion by Manual Vacuum Aspiration (MVA

    Directory of Open Access Journals (Sweden)

    Arifa Akter Jahan

    2012-07-01

    Full Text Available Background: Abortion is an important social and public health issue. In Bangladesh complication from unsafe abortion is one of the leading causes of maternal mortality. It is a serious health problem. World Health Organisation estimates that 14% of maternal deaths which occur every year in the countries of South Asia including Bangladesh are due to abortion. Study shows manual vacuum aspiration procedure is safe and effective in incomplete abortion. Very few clinical trials were carried out in Bangladesh to assess the safety and effectivity of manual vacuum aspiration in managing incomplete abortion. Objective: To find out the outcome of manual vacuum aspiration in the management of patients of incomplete abortion. Materials and Methods: This observational descriptive study was conducted in the department of Obstetrics & Gynaecology, Dhaka Medical College & Hospital from June to December, 2004. One hundred cases of diagnosed incomplete abortion up to 12 weeks of gestation were managed by manual vacuum aspiration during this period. A data recording sheet was designed for this purpose. Haemodynamically stable patients with no history of induced abortion and fever were enrolled. Results: Procedure time of manual vacuum aspiration was short, average duration was 7 minutes. Bleeding was minimum (20-30 mL in 67% cases and weighted mean was 29.80 mL. Eighty three percent patients were stable during the procedure and only 3% needed blood transfusion. Nonnarcotic analgesics were used in 59% cases and 33% needed only proper counselling. Average duration of hospital stay was 2 hours. Effectiveness of the procedure was about 98% with very low post procedure complication rate (2%. Conclusion: MVA procedure is a safe and effective technique of uterine evacuation in incomplete abortion. It is quick, less expensive, effective and less painful. Hospital stay and chance of perforation of uterus is less. So this procedure should be considered by health care

  7. Disentangling complete and incomplete fusion for 9Be+187Re system at near barrier energies

    International Nuclear Information System (INIS)

    Kharab, Rajesh; Chahal, Rajiv; Rajiv Kumar

    2015-01-01

    The breakup of projectile before fusion leads to some unusual fusion mechanisms like incomplete fusion (ICF) and sequential complete fusion (SCF). Experimentally, it is not possible to separate SCF events from direct complete fusion (DCF). However, the complete fusion and incomplete fusion can be measured separately. Theoretically it is very difficult to calculate the complete and incomplete fusion cross section separately using different models. Very recently A. Diaz-Torres has developed a computer code platypus based on classical dynamical model wherein the complete and incomplete fusion cross sections are calculated separately. But this model is found to work very well at energies above the barrier energy. Here we have attempted to extrapolate the results of the code platypus by using simple Wong's formula in conjunction with the energy dependent Woods-Saxon potential (EDWSP) in the below barrier energy region

  8. Experimental Determination of Multipartite Entanglement with Incomplete Information

    Directory of Open Access Journals (Sweden)

    G. H. Aguilar

    2015-09-01

    Full Text Available Multipartite entanglement is very poorly understood despite all the theoretical and experimental advances of the last decades. Preparation, manipulation, and identification of this resource is crucial for both practical and fundamental reasons. However, the difficulty in the practical manipulation and the complexity of the data generated by measurements on these systems increase rapidly with the number of parties. Therefore, we would like to experimentally address the problem of how much information about multipartite entanglement we can access with incomplete measurements. In particular, it was shown that some types of pure multipartite entangled states can be witnessed without measuring the correlations [M. Walter et al., Science 340, 1205 (2013] between parties, which is strongly demanding experimentally. We explore this method using an optical setup that permits the preparation and the complete tomographic reconstruction of many inequivalent classes of three- and four-partite entangled states, and compare complete versus incomplete information. We show that the method is useful in practice, even for nonpure states or nonideal measurement conditions.

  9. Value of liver elastography and abdominal ultrasound for detection of complications of allogeneic hemopoietic SCT.

    Science.gov (United States)

    Karlas, T; Weber, J; Nehring, C; Kronenberger, R; Tenckhoff, H; Mössner, J; Niederwieser, D; Tröltzsch, M; Lange, T; Keim, V

    2014-06-01

    Hepatic complications contribute to morbidity and mortality after allogeneic hemopoietic SCT. Liver Doppler ultrasound and elastography represent promising methods for pretransplant risk assessment and early detection of complications. Ultrasound (liver and spleen size, liver perfusion) and elastography (transient elastography (TE); right liver lobe acoustic radiation force impulse imaging (r-ARFI); left liver lobe ARFI (l-ARFI)) were prospectively evaluated in patients with indications for allo-SCT. Measurements were performed before and repeatedly after SCT. Results were compared with the incidence of life-threatening complications and death during the first 150 days after SCT. Of 59 included patients, 16 suffered from major complications and 9 of them died within the follow-up period. At baseline, liver and spleen size, liver perfusion, TE and r-ARFI did not differ significantly between patients with and without severe complications. In contrast, l-ARFI was significantly elevated in patients who later developed severe complications (1.58±0.30 m/s vs 1.37±0.27 m/s, P=0.030). After SCT, l-ARFI values remained elevated and TE showed increasing liver stiffness in patients with complications. The value of conventional liver ultrasound for prediction of severe SCT complications is limited. Increased values for TE and l-ARFI are associated with severe SCT complications and demand further evaluation.

  10. [Assessment of the sonographer's knowledge on the second trimester ultrasound recommendations of the National Technical Committee of Ultrasound].

    Science.gov (United States)

    Matar, M; Picone, O; Dalmon, C; Ayoubi, J-M

    2013-09-01

    To evaluate the sonographers' knowledge of the National Technical Committee of Ultrasound's recommendations concerning second trimester ultrasound. Anonymous questionnaire was sent by e-mails containing 25 questions about demographic elements, the practice of second trimester ultrasound and the recommendations of the National Technical Committee of Ultrasound about second trimester ultrasound. Six hundred and eighty-four responses were obtained. Six hundred and fifty-three upon 684 (95%) of respondents practice second trimester ultrasound and 635 upon 653 (97%) know about the existence of the report of the National Technical Committee of Ultrasound. The rates of correct answers concerning recommended biometrical images vary between 97% for the biparietal diameter and head circumference, 98% for abdominal circumference and 100% for the femur length. While for morphological images, rates vary between 52% and 100%. A subgroup analysis (whether the respondents have already read the recommendations or not) showed that those who had read the recommendations have significantly better results than those who did not. Those who have already read the recommendations have better knowledge and global knowledge can be improved. National recommendations serve to promote a policy of quality assurance of ultrasound and may be used in medicolegal issues. The societies that make recommendations should more diffuse their work and practitioners should make effort to pursue the continuing medical education and to implement the recommendations. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Directory of Open Access Journals (Sweden)

    Margaret Salmon

    Full Text Available This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  12. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Science.gov (United States)

    Salmon, Margaret; Salmon, Christian; Bissinger, Alexa; Muller, Mundenga Mutendi; Gebreyesus, Alegnta; Geremew, Haimanot; Wendel, Sarah K; Wendell, Sarah; Azaza, Aklilu; Salumu, Maurice; Benfield, Nerys

    2015-01-01

    This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania) and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  13. Ultrasound-based tumor movement compensation during navigated laparoscopic liver interventions.

    Science.gov (United States)

    Shahin, Osama; Beširević, Armin; Kleemann, Markus; Schlaefer, Alexander

    2014-05-01

    Image-guided navigation aims to provide better orientation and accuracy in laparoscopic interventions. However, the ability of the navigation system to reflect anatomical changes and maintain high accuracy during the procedure is crucial. This is particularly challenging in soft organs such as the liver, where surgical manipulation causes significant tumor movements. We propose a fast approach to obtain an accurate estimation of the tumor position throughout the procedure. Initially, a three-dimensional (3D) ultrasound image is reconstructed and the tumor is segmented. During surgery, the position of the tumor is updated based on newly acquired tracked ultrasound images. The initial segmentation of the tumor is used to automatically detect the tumor and update its position in the navigation system. Two experiments were conducted. First, a controlled phantom motion using a robot was performed to validate the tracking accuracy. Second, a needle navigation scenario based on pseudotumors injected into ex vivo porcine liver was studied. In the robot-based evaluation, the approach estimated the target location with an accuracy of 0.4 ± 0.3 mm. The mean navigation error in the needle experiment was 1.2 ± 0.6 mm, and the algorithm compensated for tumor shifts up to 38 mm in an average time of 1 s. We demonstrated a navigation approach based on tracked laparoscopic ultrasound (LUS), and focused on the neighborhood of the tumor. Our experimental results indicate that this approach can be used to quickly and accurately compensate for tumor movements caused by surgical manipulation during laparoscopic interventions. The proposed approach has the advantage of being based on the routinely used LUS; however, it upgrades its functionality to estimate the tumor position in 3D. Hence, the approach is repeatable throughout surgery, and enables high navigation accuracy to be maintained.

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on x-ray images. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  15. Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice

    Science.gov (United States)

    Price, Anthony N.; Jackson, Laurence H.; Taylor, Valerie; David, Anna L.; Lythgoe, Mark F.; Stuckey, Daniel J.

    2017-01-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high‐temporal‐resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user‐independent technique. Here, we investigated the performance of high‐temporal‐resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in‐house, high‐temporal‐resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom‐made, open‐source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high‐frequency, pulsed‐wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high‐temporal‐resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high‐temporal‐resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high‐temporal‐resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. PMID:28643891

  16. Incomplete Continuous-time Securities Markets with Stochastic Income Volatility

    DEFF Research Database (Denmark)

    Christensen, Peter Ove; Larsen, Kasper

    2014-01-01

    We derive closed-form solutions for the equilibrium interest rate and market price of risk processes in an incomplete continuous-time market with uncertainty generated by Brownian motions. The economy has a finite number of heterogeneous exponential utility investors, who receive partially...

  17. Incomplete Continuous-Time Securities Markets with Stochastic Income Volatility

    DEFF Research Database (Denmark)

    Christensen, Peter Ove; Larsen, Kasper

    In an incomplete continuous-time securities market governed by Brownian motions, we derive closed-form solutions for the equilibrium risk-free rate and equity premium processes. The economy has a finite number of heterogeneous exponential utility investors, who receive partially unspanned income ...

  18. Incomplete contour representations and shape descriptors : ICR test studies

    NARCIS (Netherlands)

    Ghosh, Anarta; Petkov, Nicolai; Gregorio, MD; DiMaio,; Frucci, M; Musio, C

    2005-01-01

    Inspired by psychophysical studies of the human cognitive abilities we propose a novel aspect and a method for performance evaluation of contour based shape recognition algorithms regarding their robustness to incompleteness of contours. We use complete contour representations of objects as a

  19. Optimizing incomplete sample designs for item response model parameters

    NARCIS (Netherlands)

    van der Linden, Willem J.

    Several models for optimizing incomplete sample designs with respect to information on the item parameters are presented. The following cases are considered: (1) known ability parameters; (2) unknown ability parameters; (3) item sets with multiple ability scales; and (4) response models with

  20. Can we make the second incompleteness theorem coordinate free?

    NARCIS (Netherlands)

    Visser, A.

    2008-01-01

    Is it possible to give a coordinate free formulation of the Second Incompleteness Theorem? We pursue one possible approach to this question. We show that (i) cutfree consistency for finitely axiomatized theories can be uniquely characterized modulo EA-provable equivalence, (ii) consistency

  1. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    Science.gov (United States)

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  2. Heat transfer enhancement using 2MHz ultrasound.

    Science.gov (United States)

    Bulliard-Sauret, Odin; Ferrouillat, Sebastien; Vignal, Laure; Memponteil, Alain; Gondrexon, Nicolas

    2017-11-01

    The present work focuses on possible heat transfer enhancement from a heating plate towards tap water in forced convection by means of 2MHz ultrasound. The thermal approach allows to observe the increase of local convective heat transfer coefficients in the presence of ultrasound and to deduce a correlation between ultrasound power and Nusselt number. Heat transfer coefficient under ultrasound remains constant while heat transfer coefficient under silent conditions increases with Reynolds number from 900 up to 5000. Therefore, heat transfer enhancement factor ranges from 25% up to 90% for the same energy conditions (supplied ultrasonic power=110W and supplied thermal power=450W). In the same time cavitational activity due to 2MHz ultrasound emission was characterized from mechanical and chemical viewpoints without significant results. At least, Particle Image Velocimetry (PIV) measurements have been performed in order to investigate hydrodynamic modifications due to the presence of 2MHz ultrasound. It was therefore possible to propose a better understanding of heat transfer enhancement mechanism with high frequency ultrasound. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  4. Prognostic impact of incomplete surgical clearance of radioiodine sensitive local lymph node metastases diagnosed by post-operative {sup 124}I-NaI-PET/CT in patients with papillary thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sabet, Amir; Binse, Ina; Grafe, Hong; Goerges, Rainer; Poeppel, Thorsten D.; Bockisch, Andreas; Rosenbaum-Krumme, Sandra J. [University Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany); Ezziddin, Samer [Saarland University, Department of Nuclear Medicine, Homburg (Germany)

    2016-10-15

    Nodal involvement is an independent risk factor of recurrence in papillary thyroid cancer (PTC). Neither the international guidelines nor the recently introduced ongoing risk adaptation concept consider the extent of initial surgical clearance of radioiodine sensitive lymph node metastases in their stratification systems. We investigated the prognostic relevance of incomplete initial surgical clearance in patients with purely lymphogeneous metastatic PTC (pN1 M0) despite successful radioiodine therapy. Accurate assessment of pre-ablative nodal status was attempted using PET/CT studies with both {sup 124}I-NaI and {sup 18}F-FDG along with high-resolution cervical ultrasound. Sixty-five patients with histologically diagnosed lymph node metastases (pN1 M0) were retrospectively analyzed. Patients with iodine-negative lymph node metastases diagnosed by {sup 18}F-FDG PET/CT or distant metastases were excluded from the analysis. The association of disease recurrence with the pre-ablative nodal status, as well as other baseline characteristics, were examined applying nonparametric tests for independent samples and multiple regression analysis. Patients with persistent lymph node metastases in {sup 124}I-NaI PET/CT were further divided according to the additional presence or absence of FDG-uptake in {sup 18}F-FDG PET/CT. Survival analyses were performed using Kaplan-Meier curves and the Cox proportional hazards model for uni- and multivariate analyses to assess the influence of prognostic factors on progression free survival (PFS). Incomplete metastatic lymph node resection captured by {sup 124}I-NaI PET/CT (n = 33) was an independent risk factor for recurrence (61 % vs 25 %, p = 0.006) and shorter PFS (46 months vs not reached, HR 4.0 [95 %-CI, 1.7-9.2], p = 0.001). Ultrasound could detect lymph node metastases only in 19/33 patients (58 %). Among patients with positive nodal status, FDG-avidity of metastatic iodine positive lymph nodes worsened the outcome (16 vs 69

  5. Mechanics of ultrasound elastography

    Science.gov (United States)

    Li, Guo-Yang

    2017-01-01

    Ultrasound elastography enables in vivo measurement of the mechanical properties of living soft tissues in a non-destructive and non-invasive manner and has attracted considerable interest for clinical use in recent years. Continuum mechanics plays an essential role in understanding and improving ultrasound-based elastography methods and is the main focus of this review. In particular, the mechanics theories involved in both static and dynamic elastography methods are surveyed. They may help understand the challenges in and opportunities for the practical applications of various ultrasound elastography methods to characterize the linear elastic, viscoelastic, anisotropic elastic and hyperelastic properties of both bulk and thin-walled soft materials, especially the in vivo characterization of biological soft tissues. PMID:28413350

  6. Relative ultrasound energy measurement circuit

    OpenAIRE

    Gustafsson, E.Martin I.; Johansson, Jonny; Delsing, Jerker

    2005-01-01

    A relative ultrasound energy estimation circuit has been designed in a standard 0.35-μm CMOS process, to be a part of a thumb size internet connected wireless ultrasound measurement system. This circuit measures the relative energy between received ultrasound pulses, and presents an output signal that is linear to the received energy. Post-layout simulations indicate 7 bit linearity for 500 mV input signals, 5 μsec startup and stop times, 2.6 mW power consumption during active state. The acti...

  7. Impact of ultrasound video transfer on the practice of ultrasound

    Science.gov (United States)

    Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh

    1996-05-01

    Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.

  8. Asset pricing puzzles explained by incomplete Brownian equilibria

    DEFF Research Database (Denmark)

    Christensen, Peter Ove; Larsen, Kasper

    We examine a class of Brownian based models which produce tractable incomplete equilibria. The models are based on finitely many investors with heterogeneous exponential utilities over intermediate consumption who receive partially unspanned income. The investors can trade continuously on a finit...... markets. Consequently, our model can simultaneously help explaining the risk-free rate and equity premium puzzles....

  9. Pulse Compression Techniques for Laser Generated Ultrasound

    Science.gov (United States)

    Anastasi, R. F.; Madaras, E. I.

    1999-01-01

    Laser generated ultrasound for nondestructive evaluation has an optical power density limit due to rapid high heating that causes material damage. This damage threshold limits the generated ultrasound amplitude, which impacts nondestructive evaluation inspection capability. To increase ultrasound signal levels and improve the ultrasound signal-to-noise ratio without exceeding laser power limitations, it is possible to use pulse compression techniques. The approach illustrated here uses a 150mW laser-diode modulated with a pseudo-random sequence and signal correlation. Results demonstrate the successful generation of ultrasonic bulk waves in aluminum and graphite-epoxy composite materials using a modulated low-power laser diode and illustrate ultrasound bandwidth control.

  10. Ultrasound in sports medicine-A critical evaluation

    International Nuclear Information System (INIS)

    Allen, Gina M.; Wilson, David J.

    2007-01-01

    This article will discuss the aspects of sports medicine where ultrasound imaging has advantages when compared to MRI looking at the strengths and weaknesses of ultrasound in the context of diagnosis and management. It will also assess the use of ultrasound in therapy including guided injections and current thoughts on novel forms of treatment. We will particularly emphasise the role of ultrasound imaging in the management of injuries of tendon, ligament and muscle

  11. Ultrasound-Assisted Hot Air Drying of Foods

    Science.gov (United States)

    Mulet, Antonio; Cárcel, Juan Andrés; García-Pérez, José Vicente; Riera, Enrique

    This chapter deals with the application of power ultrasound, also named high-intensity ultrasound, in the hot air drying of foods. The aim of ultrasound-assisted drying is to overcome some of the limitations of traditional convective drying systems, especially by increasing drying rate without reducing quality attributes. The effects of ultrasound on drying rate are responsible for some of the phenomena produced in the internal and/or external resistance to mass transfer.

  12. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  13. Interference-free ultrasound imaging during HIFU therapy, using software tools

    Science.gov (United States)

    Vaezy, Shahram (Inventor); Held, Robert (Inventor); Sikdar, Siddhartha (Inventor); Managuli, Ravi (Inventor); Zderic, Vesna (Inventor)

    2010-01-01

    Disclosed herein is a method for obtaining a composite interference-free ultrasound image when non-imaging ultrasound waves would otherwise interfere with ultrasound imaging. A conventional ultrasound imaging system is used to collect frames of ultrasound image data in the presence of non-imaging ultrasound waves, such as high-intensity focused ultrasound (HIFU). The frames are directed to a processor that analyzes the frames to identify portions of the frame that are interference-free. Interference-free portions of a plurality of different ultrasound image frames are combined to generate a single composite interference-free ultrasound image that is displayed to a user. In this approach, a frequency of the non-imaging ultrasound waves is offset relative to a frequency of the ultrasound imaging waves, such that the interference introduced by the non-imaging ultrasound waves appears in a different portion of the frames.

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... be guided by ultrasound, are used to sample cells from organs for laboratory testing help detect the ... in which needles are used to extract sample cells from an abnormal area for laboratory testing. Ultrasound ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. Except for traumatic injury, appendicitis is the most common reason for emergency abdominal surgery. Ultrasound imaging ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) ... uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. Except for traumatic injury, ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes ...

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... safe and accurate placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound ... joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... kidneys bladder testicles ovaries uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... vomiting in young infants Because ultrasound provides real-time images, images that are renewed continuously, it also ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help ... tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  10. Neuroblastoma: treatment outcome after incomplete resection of primary tumors.

    Science.gov (United States)

    Moon, Suk-Bae; Park, Kwi-Won; Jung, Sung-Eun; Youn, Woong-Jae

    2009-09-01

    For International Neuroblastoma Staging System (INSS) stages III or IV neuroblastoma (intermediate or high risk), complete excision of the primary tumor is not always feasible. Most current studies on the treatment outcome of these patients have reported on the complete excision status. The aim of this study is to review the treatment outcome after the incomplete resection. The medical records of 37 patients that underwent incomplete resection between January 1986 and December 2005 were reviewed retrospectively. Incomplete resection was assessed by review of the operative notes and postoperative computerized tomography. Age, gender, tumor location, INSS stage, N-myc gene copy number, pre- and postoperative therapy, and treatment outcome were reviewed. The treatment outcome was evaluated according to the postoperative treatment protocol in the high-risk group. Intermediate-risk patients were treated with conventional chemotherapy, isotretinoin (ITT) and interleukin-2 (IL-2). High-risk patients were treated with peripheral blood stem cell transplantation (PBSCT), ITT, and IL-2 (N = 11). Before the introduction of PBSCT, the high-risk patients were also treated with the conventional chemotherapy (N = 19). Intermediate-risk patients (N = 5) currently have no evidence of disease (NED). For the high-risk patients (N = 32), 19 patients were treated with chemotherapy alone; 15 patients died of their disease while four patients currently have an NED status. Eight of 11 patients that underwent PBSCT are currently alive. For intermediate risk, conventional chemotherapy appears to be acceptable treatment. However, for high-risk patients, every effort should be made to control residual disease including the use of myeloablative chemotherapy, differentiating agents and immune-modulating agents.

  11. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  12. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    International Nuclear Information System (INIS)

    Arvanitis, Costas D; McDannold, Nathan; Livingstone, Margaret S

    2013-01-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood–brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood–brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that

  13. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  14. Low-intensity pulsed ultrasound: Nonunions

    Directory of Open Access Journals (Sweden)

    Dijkman Bernadette

    2009-01-01

    Full Text Available Nonunions occur in 5-10% of fractures and are characterized by the failure to heal without further intervention. Low intensity pulsed ultrasound therapy has been developed as an alternative to surgery in the treatment of nonunions. We describe a systematic review on trials of low-intensity pulsed ultrasound therapy for healing of nonunions. We searched the electronic databases Medline and the Cochrane library for articles on ultrasound and healing of nonunions published up to 2008. Trials selected for the review met the following criteria: treatment of at least one intervention group with low intensity pulsed ultrasound; inclusion of patients (humans with one or more nonunions (defined as "established" or as a failure to heal for a minimum of eight months after initial injury; and assessment of healing and time to healing, as determined radiographically. The following data were abstracted from the included studies: sample size, ultrasound treatment characteristics, nonunion location, healing rate, time to fracture healing, fracture age, and demographic information. We found 79 potentially eligible publications, of which 14 met our inclusion criteria. Of these, eight studies were used for data abstraction. Healing rates averaged 87%, (range 65.6%-100% among eight trials. Mean time to healing was 146.5 days, (range 56-219 days. There is evidence from trials that low-intensity pulsed ultrasound may be an effective treatment for healing of nonunions. More homogeneous and larger controlled series are needed to further investigate its efficacy.

  15. Accuracy and reproducibility of IOLMaster versus contact ultrasound biometry

    Directory of Open Access Journals (Sweden)

    Quan-Hao Bai

    2015-06-01

    Full Text Available AIM: To compare biometry results of IOLMaster and contact ultrasound(USanterior segment parameters, and to evaluate the calculation accuracy and repeatability of intraocular lens power in both.METHODS: Preoperative measurement of anterior segment parameters were prospectively obtained in 137 eyes of 121 subjects with the IOLMaster compared with the US. Postoperative best corrected visual acuity(BCVAand the actual diopter were measured.RESULTS: There was an excellent correlation between IOLMaster and US measurements for the ACD(r=0.823, Pr=0.996, PPCONCLUSION: Partial coherence biometry using the IOLMaster provides the more accurate and reliable anterior segment parameters measurement values. A high degree of agreement between US and IOLMaster is noted. The IOLMaster not only has the advantage of performing noncontact examinations, but also produces various additional data simultaneously and may thus obviate the need for multiple examinations.

  16. Point-of-Care Ultrasound: A Trend in Health Care.

    Science.gov (United States)

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... of vomiting in young infants Because ultrasound provides real-time images, images that are renewed continuously, it also ...

  18. Dynamic changes in cellular infiltrates with repeated cutaneous vaccination: a histologic and immunophenotypic analysis

    Directory of Open Access Journals (Sweden)

    Schaefer Jochen T

    2010-08-01

    Full Text Available Abstract Background Melanoma vaccines have not been optimized. Adjuvants are added to activate dendritic cells (DCs and to induce a favourable immunologic milieu, however, little is known about their cellular and molecular effects in human skin. We hypothesized that a vaccine in incomplete Freund's adjuvant (IFA would increase dermal Th1 and Tc1-lymphocytes and mature DCs, but that repeated vaccination may increase regulatory cells. Methods During and after 6 weekly immunizations with a multipeptide vaccine, immunization sites were biopsied at weeks 0, 1, 3, 7, or 12. In 36 participants, we enumerated DCs and lymphocyte subsets by immunohistochemistry and characterized their location within skin compartments. Results Mature DCs aggregated with lymphocytes around superficial vessels, however, immature DCs were randomly distributed. Over time, there was no change in mature DCs. Increases in T and B-cells were noted. Th2 cells outnumbered Th1 lymphocytes after 1 vaccine 6.6:1. Eosinophils and FoxP3+ cells accumulated, especially after 3 vaccinations, the former cell population most abundantly in deeper layers. Conclusions A multipeptide/IFA vaccine may induce a Th2-dominant microenvironment, which is reversed with repeat vaccination. However, repeat vaccination may increase FoxP3+T-cells and eosinophils. These data suggest multiple opportunities to optimize vaccine regimens and potential endpoints for monitoring the effects of new adjuvants. Trail Registration ClinicalTrials.gov Identifier: NCT00705640

  19. Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow.

    Science.gov (United States)

    Morgan, Tara A; Jha, Priyanka; Poder, Liina; Weinstein, Stefanie

    2018-04-09

    Ultrasound is routinely used as the first imaging exam for evaluation of renal transplants and can identify most major surgical complications and evaluate vascularity with color Doppler. Ultrasound is limited, however, in the detection of parenchymal disease processes and Doppler evaluation is also prone to technical errors. Multiple new ultrasound applications have been developed and are under ongoing investigation which could add additional diagnostic capability to the routine ultrasound exam with minimal additional time, cost, and patient risk. Contrast-enhanced ultrasound (CEUS) can be used off-label in the transplant kidney, and can assist in detection of infection, trauma, and vascular complications. CEUS also can demonstrate perfusion of the transplant assessed quantitatively with generation of time-intensity curves. Future directions of CEUS include monitoring treatment response and microbubble targeted medication delivery. Elastography is an ultrasound application that can detect changes in tissue elasticity, which is useful to diagnose diffuse parenchymal disease, such as fibrosis, otherwise unrecognizable with ultrasound. Elastography has been successfully applied in other organs including the liver, thyroid, and breast; however, it is still under development for use in the transplant kidney. Unique properties of the transplant kidney including its heterogeneity, anatomic location, and other technical factors present challenges in the development of reference standard measurements. Lastly, B-flow imaging is a flow application derived from B-mode. This application can show the true lumen size of a vessel which is useful to depict vascular anatomy and bypasses some of the pitfalls of color Doppler such as demonstration of slow flow.

  20. Ultrasound diagnosis of rectus sheath hematoma

    International Nuclear Information System (INIS)

    Hwang, M. S.; Chang, J. C.; Rhee, C. B.

    1984-01-01

    6 cases of rectus sheath hematoma were correctly diagnosed by ultrasound. 2 cases had bilateral rectus sheath hematoma and 4 cases were unilateral. On ultrasound finding, relatively well defined oval or spindle like cystic mass situated in the area of rectus muscle on all cases. Ultrasound examination may give more definite diagnosis and extension rectus sheath hematoma and also helpful to follow up study of hematoma