WorldWideScience

Sample records for repeated blood sampling

  1. Novel Approach to Repeated Arterial Blood Sampling in Small Animal PET : Application in a Test-Retest Study with the Adenosine A1 Receptor Ligand [C-11]MPDX

    NARCIS (Netherlands)

    Sijbesma, Jürgen W A; Zhou, Xiaoyun; Vállez García, David; Houwertjes, Martin C; Doorduin, Janine; Kwizera, Chantal; Maas, Bram; Meerlo, Peter; Dierckx, Rudi A; Slart, Riemer H J A; Elsinga, Philip H; van Waarde, Aren

    2016-01-01

    Small animal positron emission tomography (PET) can be used to detect small changes in neuroreceptor availability. This often requires rapid arterial blood sampling. However, current catheterization procedures do not allow repeated blood sampling. We have developed a procedure which allows arterial

  2. [A comparison of the rates of hemolysis and repeated blood sampling using syringe needles versus vacuum tube needles in the emergency department].

    Science.gov (United States)

    Sung, Young Hee; Hwang, Moon Sook; Lee, Jee Hyang; Park, Hyung Doo; Ryu, Kwang Hyun; Cho, Myung Sook; Yi, Young Hee; Song, S

    2012-06-01

    This study was done to compare the rates of hemolysis and repeated sampling in blood samples obtained by a syringe needle versus a vacuum tube needle. A randomized, prospective study was used to evaluate the differences between the two blood sampling methods. The study group consisted of patients seen in the emergency department (ED) for blood sampling to determine electrolyte level. ED patients were randomly assigned to either the syringe group or the vacuum tube group. All blood samples were collected by experienced ED nurses and hemolysis was determined by experienced laboratory technologists. Data were analyzed using Fisher's exact test and binary logistic regression. One hundred forty-five valid samples were collected (74 in the syringe group versus 71 in the vacuum tube group). 5 of 74 (6.8%) blood samples in the syringe group and 8 of 71 (11.3%) in the vacuum tube group hemolyzed. Repeated blood sampling occurred for 2 of 74 (2.7%) and 3 of 71 (4.2%) in each group respectively. There were no significant differences in rates of hemolysis and repeated sampling between two groups (B=1.97, p=.204; B=2.36, p=.345). Venipuncture with syringe needles can be recommended for ED nurses to obtain blood samples.

  3. Manual versus automated blood sampling

    DEFF Research Database (Denmark)

    Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...

  4. Neonatal blood gas sampling methods

    African Journals Online (AJOL)

    S. A. J ournal of Child He alth. ARTICLE. Blood gas sampling is part of everyday practice in the care of ... 100 g. He had been ventilated since the first few hours of life, initially ..... Arch Dis Child 1988;63(7):743-747. 3. .... Kim EH, Cohen RS, Ramachandran P. Effect of vascular puncture on blood ... Williamson D, Holt PJ.

  5. Hemolysis associated with pneumatic tube system transport for blood samples.

    Science.gov (United States)

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis.

  6. Percutaneous umbilical cord blood sampling - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100196.htm Percutaneous umbilical cord blood sampling - series—Normal anatomy To use the ... or blood disorder, your doctor may recommend percutaneous umbilical cord blood sampling (PUBS), which is performed at 18 ...

  7. Stability of Blood Samples for Hemoglobin Electrophoresis

    Directory of Open Access Journals (Sweden)

    Yadira Valdés Fraser

    2013-07-01

    Full Text Available Background: the National Medical Genetics Center has conducted the prenatal screening for hemoglobinopathies in the province of Artemisa and the quality control of this program nationwide; reliability of the results is determined by the quality of the samples used. Objective: to describe the stability of whole blood samples using EDTAK2 and heparin as anticoagulants. Methods: a descriptive study of 100 samples of whole blood from pregnant women and their husbands was conducted at the National Medical Genetics Center. Hemoglobin electrophoresis with Hydrasis technology was performed using 10 % EDTAK2, 2.2 % and 5 % heparin, temperature at 4-8 0C and shelf-life of 7.15 and 30 days. Results: samples with EDTAK2 showed stability for a month with accuracy and repeatability in the electrophoresis runs. By using 5 % and 2.2 % heparin, problems were found in all periods analyzed. Conclusions: 10 % EDTAK2 anticoagulant is appropriate to ensure the reliability of the results in the screening for hemoglobinopathies. The results obtained in this study can be applied in all clinical, hematological and hemoglobin electrophoresis laboratories.

  8. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  9. [Blood loss in dialysis in repeatedly used capillary dialysators].

    Science.gov (United States)

    Schmidt, U; Senf, L; Kleinert, P; Thieler, H; Marx, M

    1980-11-01

    The blood losses increase to the twofold to threefold by capillary dialysators C-DAK 4 and C-DAK 5 are about 6.8 ml and 26 ml, respectively, in the first use. In repeated use of the C-DAK 4 the blood losses by the C-DAK 5, however, are so high that it is not to be advised to use them manifold under our conditions of dialysis. By an increase of the reperfusion quantity from 150 to 250 ml of electrolyte solution for one C-DAK 4 blood losses may considerably be reduced. In a parallel switching of two C-DAK 4 each exemplar should be perfused individually.

  10. Repeated measurement sampling in genetic association analysis with genotyping errors.

    Science.gov (United States)

    Lai, Renzhen; Zhang, Hong; Yang, Yaning

    2007-02-01

    Genotype misclassification occurs frequently in human genetic association studies. When cases and controls are subject to the same misclassification model, Pearson's chi-square test has the correct type I error but may lose power. Most current methods adjusting for genotyping errors assume that the misclassification model is known a priori or can be assessed by a gold standard instrument. But in practical applications, the misclassification probabilities may not be completely known or the gold standard method can be too costly to be available. The repeated measurement design provides an alternative approach for identifying misclassification probabilities. With this design, a proportion of the subjects are measured repeatedly (five or more repeats) for the genotypes when the error model is completely unknown. We investigate the applications of the repeated measurement method in genetic association analysis. Cost-effectiveness study shows that if the phenotyping-to-genotyping cost ratio or the misclassification rates are relatively large, the repeat sampling can gain power over the regular case-control design. We also show that the power gain is not sensitive to the genetic model, genetic relative risk and the population high-risk allele frequency, all of which are typically important ingredients in association studies. An important implication of this result is that whatever the genetic factors are, the repeated measurement method can be applied if the genotyping errors must be accounted for or the phenotyping cost is high.

  11. Non-terminal blood sampling techniques in guinea pigs.

    Science.gov (United States)

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  12. Mathematic principles of interrupted-sampling repeater jamming (ISRJ)

    Institute of Scientific and Technical Information of China (English)

    WANG XueSong; LIU JianCheng; ZHANG WenMing; FU QiXiang; LIU Zhong; XIE XiaoXia

    2007-01-01

    Coherent jamming is one of the important trends in modern radar electronic warfare. High-speed sampling of wideband radio frequency (RF) signals and high isolation of two receive-transmit antennas are key technologies for the realization of coherent jamming. However, these technologies present significant challenges to engineering application. In this paper, a novel repeater jamming based on interrupted sampling technique is presented. For a jammer with a receive-transmit time-sharing antenna, a radar signal is sampled with a low rate by the jammer. Then, a train of false targets will be achieved after the jamming signal feed the matched filter of a pulse compression radar. For the case of the linear frequency modulated (LFM) pulse compression radars, mathematic principles of the interrupted-sam- pling repeater jamming is developed, and then the efficiency of the jamming is described and stated as expressions of key parameters which are also beneficial to the jamming design for other coherent radars.

  13. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak;

    2012-01-01

    , a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were......Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover...... design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P

  14. Single-step blood direct PCR: A robust and rapid method to diagnose triplet repeat disorders.

    Science.gov (United States)

    Singh, Inder; Swarup, Vishnu; Shakya, Sunil; Goyal, Vinay; Faruq, Mohammed; Srivastava, Achal Kumar

    2017-08-15

    DNA extraction prior to polymerase chain reaction (PCR) amplification in genetic diagnoses of triplet repeat disorders (TRDs) is tedious and labour-intensive and has the limitations of sample contamination with foreign DNA, including that from preceding samples. Therefore, we aimed to develop a rapid, robust, and cost-effective method for expeditious genetic investigation of TRDs from whole blood as a DNA template. Peripheral blood samples were collected from 70 clinically suspected patients of progressive ataxia. The conventional method using genomic DNA and single-step Blood-Direct PCR (BD-PCR) method with just 2μl of whole blood sample were tested to amplify triplet repeat expansion in genes related to spinocerebellar ataxia (SCA) types 1, 2, 3, 12 and Friedreich's ataxia (FRDA). Post-PCR, the allele sizes were mapped and repeat numbers were calculated using GeneMapper and macros run in Microsoft Excel programmes. Successful amplification of target regions was achieved in all samples by both methods. The frequency of the normal and mutated allele was concordant between both methods, diagnosing 37% positive for a mutation in either of the candidate genes. The BD-PCR resulted in higher intensities of product peaks of normal and pathogenic alleles. The nearly-accurate sizing of the normal and expanded allele was achieved in a shorter time (4-5h), without DNA extraction and any risk of cross contamination, which suggests the BD-PCR to be a reliable, inexpensive, and rapid method to confirm TRDs. This technique can be introduced in routine diagnostic procedures of other tandem repeat disorders. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate....... Our study suggests that the blood transcriptome of healthy individuals is reproducible over a time period of several months. © 2013 Elsevier Inc....

  16. Repeated blood flow restriction induces muscle fiber hypertrophy.

    Science.gov (United States)

    Sudo, Mizuki; Ando, Soichi; Kano, Yutaka

    2017-02-01

    We recently developed an animal model to investigate the effects of eccentric contraction (ECC) and blood flow restriction (BFR) on muscle tissue at the cellular level. This study clarified the effects of repeated BFR, ECC, and BFR combined with ECC (BFR+ECC) on muscle fiber hypertrophy. Male Wistar rats were assigned to 3 groups: BFR, ECC, and BFR+ECC. The contralateral leg in the BFR group served as a control (CONT). Muscle fiber cross-sectional area (CSA) of the tibialis anterior was determined after the respective treatments for 6 weeks. CSA was greater in the BFR+ECC group than in the CONT (P muscle fiber hypertrophy at the cellular level. Muscle Nerve 55: 274-276, 2017. © 2016 Wiley Periodicals, Inc.

  17. Non-terminal blood sampling techniques in Guinea pigs

    DEFF Research Database (Denmark)

    Birck, Malene Muusfeldt; Tveden-Nyborg, Pernille; Lindblad, Maiken Marie

    2014-01-01

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical feature...... not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility....... of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require...... repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e...

  18. Fetal scalp blood sampling during labor

    DEFF Research Database (Denmark)

    Chandraharan, Edwin; Wiberg, Nana

    2014-01-01

    and Clinical Excellence guideline considers that fetal scalp blood sampling decreases instrumental delivery without differences in other outcome variables. The fetal scalp is supplied by vessels outside the skull below the level of the cranial vault, which is likely to be compressed during contractions......Fetal cardiotocography is characterized by low specificity; therefore, in an attempt to ensure fetal well-being, fetal scalp blood sampling has been recommended by most obstetric societies in the case of a non-reassuring cardiotocography. The scientific agreement on the evidence for using fetal...... scalp blood sampling to decrease the rate of operative delivery for fetal distress is ambiguous. Based on the same studies, a Cochrane review states that fetal scalp blood sampling increases the rate of instrumental delivery while decreasing neonatal acidosis, whereas the National Institute of Health...

  19. Trace minerals profile of blood serum and estrual mucus in repeat breeder Kankrej cows

    Directory of Open Access Journals (Sweden)

    N F Chaudhari

    2013-06-01

    Full Text Available Aim: The study was carried out with an idea to ascertain involvement of trace minerals in failure of conception in Knakrej cow. Materials and Methods: The animals under study were comprised of 10 normal (Group-I and 20 repeat breeder (Group-II Kankrej cows. Blood samples of each repeat breeding and normally cycling cows was collected before Artificial insemination. The mucus samples were collected aseptically before breeding. The cervical mucus was diluted with triple glass distilled water at the rate of 1: 3 using vertex machine. The diluted mucus and serum was used for the trace minerals estimation. Results: The values observed for copper, iron, zinc and manganese in blood serum of normal and repeat breeding animals was 2.27 ± 0.05 vs 0.87 ± 0.02, 1.41 ± 0.02 vs 0.65 ± 0.01, 1.94 ± 0.01 vs 1.78 ± 0.02 and 0.43 ± 0.02 vs 0.18 ± 0.01 ppm, respectively and in estrual mucus it was 1.37 ± 0.10 vs 0.44 ± 0.06, 0.74 ± 0.07 vs 0.33 ± 0.05, 1.47 ± 0.10 vs 0.82 ± 0.06 and 0.29 ± 0.04 vs 0.23 ± 0.03 ppm, respectively. All the values in blood serum and estrual mucus were significantly (p<0.01 higher in normal than repeat breeder cows except manganese in estrual mucus, which was non significantly higher in normal as compared to repeat breeder Kankrej cows. Conclusion: All trace minerals was higher in blood serum of normal animals as compared to repeat breeder. In estrual mucus except manganese, all trace minerals was higher in normal cows than repeat breeder. [Vet World 2013; 6(3.000: 143-146

  20. [Verification of complete blood cell count (CBC) data from heparinized blood gas samples].

    Science.gov (United States)

    Sakoguchi, Takafumi; Fujii, Seiji; Inuzumi, Koji; Kaminoh, Yoshiroh; Hirose, Munetaka; Masaki, Mitsuru; Koshiba, Masahiro

    2014-02-01

    Complete blood cell count (CBC) data from heparinized blood gas (H-Gas) samples were verified with primary focus on the platelet count (PLT). When a part of H-Gas sample was taken to a separation tube from the blood collection syringe and CBC of the sample in the separation tube was repeatedly measured (Procedure 1), the PLT from 5 samples relative to that obtained immediately after the separation was gradually reduced to 72.6-94.2% during serial measurements (every 5 minutes, up to 30 minutes). The change in the scattergram pattern suggested that this PLT decrease was due to the formation of platelet clumps. The white blood cell count (WBC), red blood cell count (RBC), hemoglobin (Hb) and hematocrit (Ht) values did not significantly change during the repeated measurements. On the other hand, PLT was significantly improved to 96.8-99.8% when the H-Gas sample was kept in the blood collection syringe so as to minimizing the exposure to the air, and the sample for the measurement from H-Gas was taken every time to separation tube from the syringe, followed by CBC measurement without delay (Procedure 2). In addition, while there were significant variations (CV: 11.8-18.2%) in PLT reproducibility among H-Gas samples by Procedure 1, measurements utilizing the Procedure 2 resulted in much smaller variations (CV: 2.2-3.7%). Thus the CBC data obtained from H-Gas samples were equivalent to those from EDTA samples when the Procedure 2 was applied. These data suggest that H-Gas samples can be used for the accurate CBC measurement, including PLT, by applying the Procedure 2.

  1. Serial follow-up of repeat voluntary blood donors reactive for anti-HCV ELISA

    Directory of Open Access Journals (Sweden)

    Choudhury N

    2011-01-01

    Full Text Available Background : Voluntary non-remunerated repeat blood donors are perceived to be safer than the first time blood donors. This study was planned for follow-up of previous hepatitis C virus (HCV test results of anti-HCV enzyme-linked immunosorbent assay (ELISA reactive repeat blood donors. The aim was to suggest a protocol for re-entry of the blood donors who are confirmed HCV negative by nucleic acid test (NAT and recombinant immunoblot assay (RIBA. A group of repeat voluntary donors were followed retrospectively who became reactive on a cross sectional study and showed HCV reactivity while donating blood regularly. Material and Methods: A total of 51,023 voluntary non remunerated blood donors were screened for anti-HCV ELISA routinely. If anybody showed positivity, they were tested by two ELISA kits (screening and confirmatory and then confirmed infection status by NAT and or RIBA. The previous HCV test results of repeat donors reactive by anti-HCV ELISA were looked back from the records. Data of donors who were repeat reactive with single ELISA kit (in the present study were analyzed separately from those reactive with two ELISA kits (in the present study. Results: In this study, 140 (0.27% donors who were reactive by anti HCV ELISA were included. Out of them, 35 were repeat voluntary donors and 16 (11.43% were reactive with single ELISA kit. All 16 donors were reactive by single ELISA kit occasionally in previous donations. Their present ELISA positive donations were negative for HCV NAT and RIBA. A total of 19 (13.57% donors were reactive with two ELISA kits. In their previous donations, the donors who were reactive even once with two ELISA kits were consistently reactive by the same two ELISA kits in their next donations also. Conclusion: Donor sample reactive by only single ELISA kit may not be considered as infectious for disposal as they were negative by NAT and or RIBA. One time ELISA positivity was found probably due to ELISA kit

  2. Enhanced detection of polymicrobic bacteremia by repeat subculture of previously positive blood cultures.

    OpenAIRE

    Hansen, S.L.; Hetmanski, J

    1983-01-01

    Blood subcultures repeated 3 days after the cultures were first identified as positives increased our detection of polymicrobic bacteremia in 9.1 to 27% of clinically significant patient episodes. Reincubation and repeated subculture of previously positive blood cultures had a direct impact on the therapeutic management of patients with polymicrobic bacteremia.

  3. Improving blood sample logistics using simulation

    DEFF Research Database (Denmark)

    Jørgensen, Pelle Morten Thomas; Jacobsen, Peter

    2012-01-01

    Using simulation as an approach to display and improve internal logistics and handling at hospitals has great potential. This research will show how a simulation model can be used to evaluate changes made to two different cases of transportation of blood samples at a hospital, by evaluating...

  4. Possibility of enhanced risk of retinal neovascularization in repeated blood donors: blood donation and retinal alteration

    Directory of Open Access Journals (Sweden)

    Rastmanesh R

    2011-09-01

    Full Text Available Reza RastmaneshDepartment of Clinical Nutrition and Dietetics, Shahid Beheshti University of Medical Sciences, National Nutrition and Food Technology Research Institute, Tehran, IranAbstract: Repeated blood donors manifest clinical, subclinical, and biochemical signs of iron deficiency anemia, have significantly higher erythropoietin and vascular endothelial growth factor (VEGF concentrations, and decreased tissue oxygen saturation, oxygenated tissue hemoglobin, and regional cerebral oxygen saturation. Erythropoietin and VEGF are potent retinal angiogenic factors which may initiate and promote the retinal angiogenesis process independently or simultaneously. Increases in circulating levels of erythropoietin and VEGF are proportionate to the levels of hematocrit, hypoxemia, and tissue hypoxia. It is suggested that higher erythropoietin production following iron deficiency anemia-induced chronic hypoxemia/hypoxia may, hypothetically, enhance the risk of retinal angiogenesis and/or neovascularization, possibly by inducing hypoxia inducible factor-1 alpha, which consequently upregulates genes stimulating angiogenesis, resulting in formation of a new vasculature, possibly by modulation of signal transducer and activator of transcription 3 signaling in the retina. Implications of this hypothesis cover erythropoietin doping, chronic hypoxia, and hypoxemic situations, such as angiogenesis-related cardiac and pulmonary diseases.Keywords: repeated blood donation, erythropoietin, retinal neovascularization, vascular endothelial growth factor, hypoxia

  5. Failure Characteristic of Laser Cladding Samples on Repeated Impact

    Institute of Scientific and Technical Information of China (English)

    SHI Shi-hong; ZHENG Qi-guang; FU Ge-yan; ZHANG Jin-ping

    2004-01-01

    Using self-made impact fatigue test instruments and related analytic devices,the mechanical components with laser cladding layer have been attempted.It is found that,on repeated impact force,several failure modes of the components include the surface cracks,surface plastic deformation,corrosive pitting and coat collapse,etc.The paper reported the test method and initial analysis conclusions about the unique failure characteristics of the mechanical components on repeated impact load.

  6. Microcontroller-based system for collecting anaerobic blood samples from a running greyhound.

    Science.gov (United States)

    Schmalzried, R T; Toll, P W; Devore, J J; Fedde, M R

    1992-04-01

    Many physiological variables change rapidly in the blood during sprint exercise. To characterize the dynamics and extent of these changes, blood samples must be obtained during exercise. We describe herein a portable, microcontroller-based system used to automatically obtain repeated, anaerobic, arterial blood samples from greyhounds before, during, and following a race on a track. In addition, the system also records the blood temperature in the pulmonary artery each time a blood sample is taken. The system has been tested for more than 2 years and has proven to be reliable and effective.

  7. Percutaneous ultrasound guided umbilical cord blood sampling

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Choi, B. I.; Kim, C. W.; Youn, B. H.; Shin, H. C.; Kim, S. O. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    This report describes a technique and the result of percutaneous ultrasound-guided umbilical cord blood sampling and its potential use in the management of diagnostic problems in the second and third trimester of pregnancy. This method has been employed in the prenatal assessment of 19 fetuses at risk for chromosomal disorders, fetal hypoxia and hematologic disorders. This simple and rapid procedure offers a safe access to the fetal circulation

  8. Consequences of repeated blood-brain barrier disruption in football players.

    Directory of Open Access Journals (Sweden)

    Nicola Marchi

    Full Text Available The acknowledgement of risks for traumatic brain injury in American football players has prompted studies for sideline concussion diagnosis and testing for neurological deficits. While concussions are recognized etiological factors for a spectrum of neurological sequelae, the consequences of sub-concussive events are unclear. We tested the hypothesis that blood-brain barrier disruption (BBBD and the accompanying surge of the astrocytic protein S100B in blood may cause an immune response associated with production of auto-antibodies. We also wished to determine whether these events result in disrupted white matter on diffusion tensor imaging (DT scans. Players from three college football teams were enrolled (total of 67 volunteers. None of the players experienced a concussion. Blood samples were collected before and after games (n = 57; the number of head hits in all players was monitored by movie review and post-game interviews. S100B serum levels and auto-antibodies against S100B were measured and correlated by direct and reverse immunoassays (n = 15 players; 5 games. A subset of players underwent DTI scans pre- and post-season and after a 6-month interval (n = 10. Cognitive and functional assessments were also performed. After a game, transient BBB damage measured by serum S100B was detected only in players experiencing the greatest number of sub-concussive head hits. Elevated levels of auto-antibodies against S100B were elevated only after repeated sub-concussive events characterized by BBBD. Serum levels of S100B auto-antibodies also predicted persistence of MRI-DTI abnormalities which in turn correlated with cognitive changes. Even in the absence of concussion, football players may experience repeated BBBD and serum surges of the potential auto-antigen S100B. The correlation of serum S100B, auto-antibodies and DTI changes support a link between repeated BBBD and future risk for cognitive changes.

  9. Consequences of Repeated Blood-Brain Barrier Disruption in Football Players

    Science.gov (United States)

    Puvenna, Vikram; Janigro, Mattia; Ghosh, Chaitali; Zhong, Jianhui; Zhu, Tong; Blackman, Eric; Stewart, Desiree; Ellis, Jasmina; Butler, Robert; Janigro, Damir

    2013-01-01

    The acknowledgement of risks for traumatic brain injury in American football players has prompted studies for sideline concussion diagnosis and testing for neurological deficits. While concussions are recognized etiological factors for a spectrum of neurological sequelae, the consequences of sub-concussive events are unclear. We tested the hypothesis that blood-brain barrier disruption (BBBD) and the accompanying surge of the astrocytic protein S100B in blood may cause an immune response associated with production of auto-antibodies. We also wished to determine whether these events result in disrupted white matter on diffusion tensor imaging (DT) scans. Players from three college football teams were enrolled (total of 67 volunteers). None of the players experienced a concussion. Blood samples were collected before and after games (n = 57); the number of head hits in all players was monitored by movie review and post-game interviews. S100B serum levels and auto-antibodies against S100B were measured and correlated by direct and reverse immunoassays (n = 15 players; 5 games). A subset of players underwent DTI scans pre- and post-season and after a 6-month interval (n = 10). Cognitive and functional assessments were also performed. After a game, transient BBB damage measured by serum S100B was detected only in players experiencing the greatest number of sub-concussive head hits. Elevated levels of auto-antibodies against S100B were elevated only after repeated sub-concussive events characterized by BBBD. Serum levels of S100B auto-antibodies also predicted persistence of MRI-DTI abnormalities which in turn correlated with cognitive changes. Even in the absence of concussion, football players may experience repeated BBBD and serum surges of the potential auto-antigen S100B. The correlation of serum S100B, auto-antibodies and DTI changes support a link between repeated BBBD and future risk for cognitive changes. PMID:23483891

  10. Occupational hazards of traditional healers: repeated unprotected blood exposures risk infectious disease transmission.

    Science.gov (United States)

    Audet, Carolyn M; Salato, José; Blevins, Meridith; Silva, Wilson; González-Calvo, Lázaro; Vermund, Sten H; Gaspar, Felisbela

    2016-11-01

    Healers provide support for acute and chronic illnesses in rural Mozambique, such as socially acceptable traditional 'vaccinations' (subcutaneous cuts in the skin to rub herbs directly into the bloody lesion). We aimed to document the frequency of blood exposure by traditional practitioners in Mozambique. We conducted surveys with a simple random sample of 236 traditional healers in Zambézia province. Chi-square and Wilcoxon rank-sum tests were used to compare 'injection' behaviours across districts. Healers treated a median of eight patients in the past month (IQR: 4-15). About 75% conducted 'injections'. These healers 'injected' a median of four patients (IQR: 1-8), used a new razor a median of three times (IQR: 1-8), and almost never used gloves. Lifetime blood exposures among those who provided 'injections' during treatments were estimated to be 1758 over a healer's career. The majority of healers are exposed repeatedly to patient blood. Given the high prevalence of HIV, hepatitis B and C virus, and other blood-borne agents, specific healer practices are an occupational hazard and reuse of razors is risky for their clients. © 2016 John Wiley & Sons Ltd.

  11. Repeated increases in blood flow, independent of exercise, enhance conduit artery vasodilator function in humans

    NARCIS (Netherlands)

    Naylor, L.H.; Carter, H.; Fitzsimons, M.G.; Cable, N.T.; Thijssen, D.H.J.; Green, D.J.

    2011-01-01

    This study aimed to determine the importance of repeated increases in blood flow to conduit artery adaptation, using an exercise-independent repeated episodic stimulus. Recent studies suggest that exercise training improves vasodilator function of conduit arteries via shear stress-mediated

  12. PTSD among a treatment sample of repeat DUI offenders.

    Science.gov (United States)

    Peller, Allyson J; Najavits, Lisa M; Nelson, Sarah E; LaBrie, Richard A; Shaffer, Howard J

    2010-08-01

    Recent studies indicate that posttraumatic stress disorder (PTSD) is one of the most common psychiatric comorbidities among driving-under-the-influence (DUI) offenders in treatment. Investigation of DUI offenders' PTSD and clinical characteristics could have important implications for prevention and treatment. This prospective study examined the demographic and clinical characteristics of repeat DUI offenders with PTSD symptoms at baseline and 1-year follow-up. Seven hundred twenty-nine DUI offenders admitted to a 2-week inpatient program participated in the study. Participants with PTSD evidenced more severe psychiatric comorbidity and reported a higher DUI recidivism rate at 1-year than those without PTSD. This study suggests a need to address PTSD among DUI offenders, as well as to further develop methodologies for accurately reporting DUI recidivism.

  13. Congener Production in Blood Samples During Preparation and Storage

    DEFF Research Database (Denmark)

    Felby, Søren; Nielsen, Erik

    1995-01-01

    Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone......Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone...

  14. Perfectionism Affects Blood Pressure in Response to Repeated Exposure to Stress.

    Science.gov (United States)

    Albert, Phebe; Rice, Kenneth G; Caffee, Lauren

    2016-04-01

    This pilot study examined the effects of perfectionism on blood pressure (BP) in response to repeated exposure to mental arithmetic stressors. College students (N = 30) in a laboratory setting were administered a series of challenging mathematical tasks. BP was measured at baseline and after each task. Multilevel modelling analyses revealed that BP tended to decline over the course of the mathematical tasks. However, higher levels of performance standards predicted relatively stable levels of systolic BP, whereas moderate and lower levels of standards predicted declines in systolic BP. Higher levels of self-critical perfectionism predicted generally sustained levels of diastolic BP, with moderate and low self-criticism predicting declines in diastolic BP during the repeated stressors. These preliminary results suggest that students with higher levels of perfectionism may be at risk for physiological problems associated with stress reactivity, perhaps especially so in situations in which they experience persistent stress. Although results were qualified by a relatively small sample size, effects were statistically significant and supported the importance of examining the short-term and long-term implications of the effects of perfectionism on cardiovascular function and the different implications of elevations in systolic and diastolic BP.

  15. Relationships between repeated sprint ability, mechanical parameters, and blood metabolites in professional soccer players.

    Science.gov (United States)

    Morcillo, Jose A; Jiménez-Reyes, Pedro; Cuadrado-Peñafiel, Victor; Lozano, Emilio; Ortega-Becerra, Manuel; Párraga, Juan

    2015-06-01

    This study analyzed the acute metabolic and mechanical responses to a specific repeated sprint ability (RSA) test. Eighteen male professional soccer players from a team of the First Division of Spanish National League participated. A 12 × 30-m RSA test with 30-second recovery together with countermovement jump test (CMJ) pre a post RSA test was performed. Mechanical responses (i.e., height performance in CMJ and speed loss) and metabolic responses (i.e., blood lactate and ammonia concentrations) were measured before and after exercise. A related sample t-test was used to analyze CMJ height pre-post changes as well as to compare pre- and post-exercise lactate and ammonia levels. Countermovement jump height loss pre-post session (8%) was significant, and fatigue, measured as CMJ height loss, was strongly correlated to lactate (r = 0.97; p < 0.001) and ammonia (r = 0.92; p < 0.001) for all players. The relationships between the variables studied were determined by calculating the Pearson correlation coefficients. The metabolic stress developed during the effort can be estimated by controlling CMJ because of the high correlation between CMJ and blood lactate and ammonia concentrations. The high correlations found between mechanical (speed and CMJ height losses) and metabolic (lactate and ammonia) measures of fatigue highlight the utility and validity of using CMJ to monitor training load and quantify objectively neuromuscular fatigue during RSA.

  16. COPD association and repeatability of blood biomarkers in the ECLIPSE cohort

    Directory of Open Access Journals (Sweden)

    Dickens Jennifer A

    2011-11-01

    Full Text Available Abstract Background There is a need for biomarkers to better characterise individuals with COPD and to aid with the development of therapeutic interventions. A panel of putative blood biomarkers was assessed in a subgroup of the Evaluation of COPD Longitudinally to Identify Surrogate Endpoints (ECLIPSE cohort. Methods Thirty-four blood biomarkers were assessed in 201 subjects with COPD, 37 ex-smoker controls with normal lung function and 37 healthy non-smokers selected from the ECLIPSE cohort. Biomarker repeatability was assessed using baseline and 3-month samples. Intergroup comparisons were made using analysis of variance, repeatability was assessed through Bland-Altman plots, and correlations between biomarkers and clinical characteristics were assessed using Spearman correlation coefficients. Results Fifteen biomarkers were significantly different in individuals with COPD when compared to former or non-smoker controls. Some biomarkers, including tumor necrosis factor-α and interferon-γ, were measurable in only a minority of subjects whilst others such as C-reactive protein showed wide variability over the 3-month replication period. Fibrinogen was the most repeatable biomarker and exhibited a weak correlation with 6-minute walk distance, exacerbation rate, BODE index and MRC dyspnoea score in COPD subjects. 33% (66/201 of the COPD subjects reported at least 1 exacerbation over the 3 month study with 18% (36/201 reporting the exacerbation within 30 days of the 3-month visit. CRP, fibrinogen interleukin-6 and surfactant protein-D were significantly elevated in those COPD subjects with exacerbations within 30 days of the 3-month visit compared with those individuals that did not exacerbate or whose exacerbations had resolved. Conclusions Only a few of the biomarkers assessed may be useful in diagnosis or management of COPD where the diagnosis is based on airflow obstruction (GOLD. Further analysis of more promising biomarkers may reveal

  17. A Way to Improve Analytic Speed of Emergency Blood Sample

    Institute of Scientific and Technical Information of China (English)

    QI Zihui; LI Jun; LIU Zisheng

    2002-01-01

    The circulatory way of eccentric hatch of seperating emergency blood sample quickly and entirely, that is the blood sample is centrifugatened first; second, hatched at 37 ℃; then adopt the circulatory way of centrifugation which can seperate quickly emergency blood sample, and collect nonfibrin serum. The serum was placed paired, and was tested automatically by Corning 644 Electrolyte Analysor and Shimadzu CL- 7000 Biochemistry Analysor after placed naturely with sample 2 hours. There has not difference between two analytic result after T test of statistics. This way shortens the seperation time of serum of emergency blood sample, improves emergency analytic speed, and has a good value on sample seperation of common automatic analysis.

  18. Repeating cytological preparations on liquid-based cytology samples: A methodological advantage?

    Science.gov (United States)

    Pinto, Alvaro P; Maia, Henrique Felde; di Loretto, Celso; Krunn, Patrícia; Túlio, Siumara; Collaço, Luis Martins

    2007-10-01

    This study investigates the rule that repeating cytological preparations on liquid-based cytology improves sample adequacy, diagnosis, microbiological, and hormonal evaluations. We reviewed 156 cases of pap-stained preparations of exfoliated cervical cells in two slides processed by DNA-Cytoliq System. After sample repeat/dilution, limiting factors affecting sample adequacy were removed in nine cases and three unsatisfactory cases were reclassified as satisfactory. Diagnosis was altered in 24 cases. Of these, the original diagnosis in 15 was atypical squamous cells of undetermined significance; after the second slide examination, diagnosis in 5 of the 15 cases changed to low-grade squamous intraepithelial lesion, 3 to high-grade squamous intraepithelial lesion, and 7 to absence of lesion. Microbiological evaluation was altered, with Candida sp. detected in two repeated slides. Repeat slide preparation or dilution of residual samples enhances cytological diagnosis and decreases effects of limiting factors in manually processed DIGENE DCS LBC.

  19. Instance-Based Learning: Integrating Sampling and Repeated Decisions from Experience

    Science.gov (United States)

    Gonzalez, Cleotilde; Dutt, Varun

    2011-01-01

    In decisions from experience, there are 2 experimental paradigms: sampling and repeated-choice. In the sampling paradigm, participants sample between 2 options as many times as they want (i.e., the stopping point is variable), observe the outcome with no real consequences each time, and finally select 1 of the 2 options that cause them to earn or…

  20. Whole Genome Amplification from Blood Spot Samples.

    Science.gov (United States)

    Sørensen, Karina Meden

    2015-01-01

    Whole genome amplification is an invaluable technique when working with DNA extracted from blood spots, as the DNA obtained from this source often is too limited for extensive genetic analysis. Two techniques that amplify the entire genome are common. Here, both are described with focus on the benefits and drawbacks of each system. However, in order to obtain the best possible WGA result the quality of input DNA extracted from the blood spot is essential, but also time consumption, flexibility in format and elution volume and price of the technology are factors influencing system choice. Here, three DNA extraction techniques are described and the above aspects are compared between the systems.

  1. Effects of repeated concentric and eccentric contractions on tendon blood circulation.

    Science.gov (United States)

    Kubo, K

    2015-06-01

    Previous studies demonstrated that treatment involving eccentric training was effective in the conservative management of chronic tendinosis. However, the mechanisms for these phenomena are unknown. The purpose of this study was to compare changes in blood circulation of the tendons after the repeated concentric and eccentric contractions. 11 healthy males volunteered for this study. Subjects performed the repeated concentric (CON) and eccentric (ECC) contractions (5 sets of 10 maximal voluntary contractions) of the plantar flexors. During and after repeated contractions, oxyhemoglobin (Oxy), deoxyhemoglobin (Deoxy), total hemoglobin (THb), and oxygen saturation (StO2) of the Achilles tendons were measured using red laser lights. Oxy and THb increased during and after ECC, but not CON. Deoxy decreased during both CON and ECC. Increase in StO2 during and after ECC was greater than that during and after CON. These results suggested that changes in blood circulation of the Achilles tendon during and after repeated eccentric contractions were more remarkable than those during and after repeated concentric contractions.

  2. Renal impairment in β thalassemia major patients receiving repeated blood transfusion

    Directory of Open Access Journals (Sweden)

    Riadi Wirawan

    2003-12-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} β-thalassemia major is a disease caused by β polypeptide chain synthesis disorder which is inherited in an autosomal recessive manner from both parents and which is marked by little or no β-globin chain synthesis. Treatment for β-thalassemia major patients is by giving repeated blood transfusions, which causes iron accumulation, leading to hemochromatosis. Iron accumulation can occur in various body organ, including the kidneys. The aim of this study was to investigate the existence of renal impairment in β-thalassemia major patients. The subjects of this study were β-thalassemia major patients aged 15 - 28 years old who had received 6 units of packed red cells or more within 6 months. In this study, urine and serum samples of the subjects were taken and examined. Assay of serum iron was performed with Hitachi 737. Results were that 94.7% patients showed an increase in transferrin saturation and 40% of them had hemochromatosis; 73.4% had microalbuminuria; 1.3% had albuminuria and 21.3% had increased urinary β2- microglobulin (β2-m. A total of 78.6% of patients showed renal impairment. Conclusion of this study suggested that

  3. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  4. Segmentation and Analysis of Cancer Cells in Blood Samples

    Directory of Open Access Journals (Sweden)

    Arjun Nelikanti

    2015-10-01

    Full Text Available Blood cancer is an umbrella term for cancers that affect the blood, bone marrow and lymphatic system. Acute Lymphoblastic Leukemia (ALL is one of the kinds of blood cancer which can be affected at any age in the humans. The analysis of peripheral blood samples is an important test in the procedures for the diagnosis of leukemia. In this paper the blood sample images are used and implementing a clustering algorithm for detection of the cancer cells. This paper also implements morphological operations and feature extraction techniques using MATLAB for the analysis of cancer cells in the images.

  5. The pathology of facial vein blood sampling in mice

    DEFF Research Database (Denmark)

    Hansen, Ket; Harslund, Jakob le Fèvre; Bollen, Peter

    2014-01-01

    vein blood sampling. Therefore, we investigated if this technique was associated with pathological changes of the jaw region. Methods: 43 NMRI mice were subjected to facial vein blood sampling by using the lancet method during 12 months, starting at the age of 8 weeks. The mice were restrained manually......Introduction: The use of retro-orbital blood sampling is prohibited in Denmark. For this reason, alternative methods are used for obtaining larger blood samples of a good quality. The facial vein is generally recommended for this. However, we have experienced discomfort for mice subjected to facial...... by the scruff and a lancet was placed 2-3 mm caudally to the freckle on the lower jaw, and the skin was punctured. After sampling, brief compression by a cotton swab was applied, if bleeding did not stop. Two days after the last blood sampling, the mice were euthanized by an overdose of pentobarbital...

  6. The pathology of facial vein blood sampling in mice

    DEFF Research Database (Denmark)

    Hansen, Ket; Harslund, Jakob le Fèvre; Bollen, Peter

    2014-01-01

    Introduction: The use of retro-orbital blood sampling is prohibited in Denmark. For this reason, alternative methods are used for obtaining larger blood samples of a good quality. The facial vein is generally recommended for this. However, we have experienced discomfort for mice subjected to facial...... vein blood sampling. Therefore, we investigated if this technique was associated with pathological changes of the jaw region. Methods: 43 NMRI mice were subjected to facial vein blood sampling by using the lancet method during 12 months, starting at the age of 8 weeks. The mice were restrained manually...... by the scruff and a lancet was placed 2-3 mm caudally to the freckle on the lower jaw, and the skin was punctured. After sampling, brief compression by a cotton swab was applied, if bleeding did not stop. Two days after the last blood sampling, the mice were euthanized by an overdose of pentobarbital...

  7. Use of filter paper blood samples for rabies antibody detection in foxes and raccoon dogs.

    Science.gov (United States)

    Wasniewski, Marine; Barrat, Jacques; Combes, Benoit; Guiot, Anne Laure; Cliquet, Florence

    2014-08-01

    The effectiveness of oral rabies vaccination in wildlife is usually evaluated by the detection of rabies antibodies. However, the assessment of rabies antibodies has several technical difficulties in the field, such as the collection, storage, transport and titration of blood samples, often of poor quality. The objective of this study was to assess the feasibility of collecting blood on a filter paper (FP) coupled with enzyme-linked immunosorbent assay (ELISA) titration of rabies antibodies in raccoon dogs and red foxes. The FP blood sampling method was found highly specific and repeatable in both species. Overall, results obtained with the FP sampling method were highly concordant with the conventional (venipuncture) sampling methods. Blood eluates from FP samples from foxes and raccoon dogs tested using ELISA showed concordance values of 92% and 95%, respectively, with serum samples tested using the seroneutralisation test and values of 95% and 91%, respectively, when the ELISA was used on both types of sample. The use of FP blood sampling coupled with the titration of rabies antibodies by ELISA provides a reliable alternative to conventional blood sampling and serum testing by seroneutralisation. This simple procedure is particularly attractive and cost-effective for assessing the effectiveness of oral rabies vaccination in field conditions.

  8. Molecular characterization of Leptospira sp by multilocus variable number tandem repeat analysis (MLVA from clinical samples: a case report

    Directory of Open Access Journals (Sweden)

    Hélène Pailhoriès

    2015-08-01

    Full Text Available Leptospirosis is a zoonotic infection for which diagnosis is difficult. It has appeared as a global emerging infectious disease over recent years. Genotype determination often requires a Leptospira strain obtained by culture, which is a long and fastidious technique. A method based on multilocus variable number tandem repeat analysis (MLVA to determine the genotype of Leptospira interrogans, performed directly on blood or urine samples, is proposed. This method was applied to a fatal case of leptospirosis for which the geographical origin of infection was unknown. This technique will allow a genotype to be obtained for L. interrogans, even when cultures remain negative.

  9. Repeated Microsphere Delivery for Serial Measurement of Regional Blood Perfusion in the Chronically Instrumented, Conscious Canine

    Science.gov (United States)

    Bartoli, Carlo R.; Okabe, Kazunori; Akiyama, Ichiro; Coull, Brent; Godleski, John J.

    2008-01-01

    INTRODUCTION For chronic, repeated hemodynamic studies in conscious dogs, we designed and tested a chronically instrumented canine, microsphere delivery model. The goals of this study were to investigate the accuracy of repeated estimations of blood perfusion using fluorescent-labeled microspheres and to develop and validate a chronic preparation that permits consecutive estimations in the same conscious animal over an extended protocol. METHODS Via thoracotomy, 9 dogs were instrumented with left atrial appendage and aortic vascular access catheters connected to subcutaneous vascular access ports (VAPs). Four animals received 7 serial injections of 1.6 million 15μm microspheres (total: 11.2 million), and five animals received 8 serial injections of 2.25 million microspheres (total: 18 million) over the course of 11 or 18 weeks. RESULTS All catheters have remained bidirectionally patent during protocol for 14.9±0.8 (Mean±SEM) weeks. Sphere accumulation did not significantly alter global myocardial (p=0.69, p=0.25), renal (p=0.92, p=0.12), hepatic (p=0.84, p=0.32), or splenic (p=0.33, p=0.70) blood perfusion in either set of animals. CONCLUSIONS Catheters remained bidirectionally patent for months, did not interfere with the hemodynamic responses of the preparation, and allowed repeat percutaneous injection of microspheres and withdrawal of reference arterial blood from within conscious canines. Eight serial injections totaling 18 million microspheres over 18 weeks did not alter regional myocardial, hepatic, renal, or splenic blood flow. This dependable, chronic, percutaneous arterial access preparation provides a means for examining acute and long-term effects of pathophysiological, pharmaceutical, and environmental influences on regional arterial blood perfusion in conscious, large animals. PMID:17632127

  10. Effects of post-sampling analysis time, type of blood samples and collection tubes on values of blood gas testing.

    Science.gov (United States)

    Smajić, Jasmina; Kadić, Damira; Hasić, Sabaheta; Serdarević, Nafija

    2015-08-01

    To investigate effects of post-sampling analysis time, a type of blood samples and collection tubes on blood gas testing. This study included 100 patients at the Clinic for Pulmonary Diseases, Clinical Centre Sarajevo. The partial pressure of oxygen (pO2) and carbon dioxide (pCO2), and the oxygen saturation level of hemoglobin (sO2) were analyzed in the arterial blood samples (ABS) and capillary blood samples (CBS) by a potentiometric method using a blood gas analyzer ABL 555 (Radiometer, Copenhagen, Denmark). Paired measurements of ABS were performed within 15 minutes and after 60 minutes from sampling and compared. The results of CBS obtained within 15 minutes were compared with matching ABS results, as well as the results obtained from CBS within 15 minutes taken into glass and plastic tubes. pO2 and sO2 values were significantly lower after 60 minutes compared to those within 15 minutes in ABS (9.20±1.89 vs. 9.51±1.95 and 91.25±5.03 vs. 92.40±4.5; pblood values were not influenced significantly (p>0.05). The length of post-sampling analysis time, a type of blood samples and collection tubes have significant impact on blood oxygen parameters. Analysis within 15 minutes after blood sampling is considered as appropriate. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  11. Repeat Victimization in a High-Risk Neighborhood Sample of Adolescents.

    Science.gov (United States)

    Menard, Scott; Huizinga, David

    2001-01-01

    Used longitudinal Denver Youth Survey data to examine repeat victimization and concentration of victimization among a relatively few high-frequency victims and intermittency of victimization in a sample of adolescents in a high-risk neighborhood. Chronic, multiple, intermittent victimization was the usual pattern among respondents. Men had higher…

  12. Effect of cold water immersion on repeated cycling performance and limb blood flow.

    Science.gov (United States)

    Vaile, J; O'Hagan, C; Stefanovic, B; Walker, M; Gill, N; Askew, C D

    2011-08-01

    The purpose of the present study was to compare the effects of cold water immersion (CWI) and active recovery (ACT) on resting limb blood flow, rectal temperature and repeated cycling performance in the heat. Ten subjects completed two testing sessions separated by 1 week; each trial consisted of an initial all-out 35-min exercise bout, one of two 15-min recovery interventions (randomised: CWI or ACT), followed by a 40-min passive recovery period before repeating the 35-min exercise bout. Performance was measured as the change in total work completed during the exercise bouts. Resting limb blood flow, heart rate, rectal temperature and blood lactate were recorded throughout the testing sessions. There was a significant decline in performance after ACT (mean (SD) -1.81% (1.05%)) compared with CWI where performance remained unchanged (0.10% (0.71%)). Rectal temperature was reduced after CWI (36.8°C (1.0°C)) compared with ACT (38.3°C (0.4°C)), as was blood flow to the arms (CWI 3.64 (1.47) ml/100 ml/min; ACT 16.85 (3.57) ml/100 ml/min) and legs (CW 4.83 (2.49) ml/100 ml/min; ACT 4.83 (2.49) ml/100 ml/min). Leg blood flow at the end of the second exercise bout was not different between the active (15.25 (4.33) ml/100 ml/min) and cold trials (14.99 (4.96) ml/100 ml/min), whereas rectal temperature (CWI 38.1°C (0.3°C); ACT 38.8°C (0.2°C)) and arm blood flow (CWI 20.55 (3.78) ml/100 ml/min; ACT 23.83 (5.32) ml/100 ml/min) remained depressed until the end of the cold trial. These findings indicate that CWI is an effective intervention for maintaining repeat cycling performance in the heat and this performance benefit is associated with alterations in core temperature and limb blood flow.

  13. Extensive monitoring through multiple blood samples in professional soccer players

    DEFF Research Database (Denmark)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter

    2013-01-01

    ABSTRACT: The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players, and to analyze different blood parameters in relation to seasonal changes in training and match exposure.Blood samples were collected five times during a six...... months period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, players were tested for body composition, VO2max and physical performance by the Yo-Yo intermittent endurance sub-max test (IE2).Multiple variations in blood parameters occurred during...... of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. VO2max decreased towards the end of the season whereas no significant changes were observed in the IE2 test.The regular blood samples from elite soccer players reveal significant changes...

  14. The DRPLA CAG repeats in an Italian population sample: evaluation of the polymorphism for forensic applications.

    Science.gov (United States)

    Pelotti, S; Mantovani, V; Esposti, P D; D'Apote, L; Bragliani, M; Maiolini, E; Abbondanza, A; Pappalardo, G

    1998-03-01

    The DRPLA CAG repeats polymorphism has been studied in an Italian population sample. PCR amplification, manual PAGE and silver staining were employed. A total of 16 different alleles, spanning the range from 5 to 21 CAG triplettes, was observed. The heterozygosity was 0.81 and no significant deviation from Hardy-Weinberg equilibrium was found 81 meioses from parentage testing were also analyzed and a Mendelian pattern of inheritance was observed in all cases. In addition, we could successfully type DRPLA locus in some forensic specimens, 1 ng of DNA allowing clear definition of alleles. The authors conclude that the DRPLA CAG repeats analysis may be useful for forensic applications.

  15. Are They Bloody Guilty? Blood Doping with Simulated Samples

    Science.gov (United States)

    Stuart, Parker E.; Lees, Kelsey D.; Milanick, Mark A.

    2014-01-01

    In this practice-based lab, students are provided with four Olympic athlete profiles and simulated blood and urine samples to test for illegal substances and blood-doping practices. Throughout the course of the lab, students design and conduct a testing procedure and use their results to determine which athletes won their medals fairly. All of the…

  16. Astronaut Joseph Kerwin takes blood sample from Astronaut Charles Conrad

    Science.gov (United States)

    1973-01-01

    Scientist-Astronaut Joseph P. Kerwin (right), Skylab 2 science pilot and a doctor of medicine, takes a blood sample from Astronaut Charles Conrad Jr., Sylab 2 commander, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. The blood sampling was part of the Skylab Hematology and Immunology Experiment M110 series.

  17. Importance of sample size for the estimation of repeater F waves in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Fang, Jia; Liu, Ming-Sheng; Guan, Yu-Zhou; Cui, Bo; Cui, Li-Ying

    2015-02-20

    In amyotrophic lateral sclerosis (ALS), repeater F waves are increased. Accurate assessment of repeater F waves requires an adequate sample size. We studied the F waves of left ulnar nerves in ALS patients. Based on the presence or absence of pyramidal signs in the left upper limb, the ALS patients were divided into two groups: One group with pyramidal signs designated as P group and the other without pyramidal signs designated as NP group. The Index repeating neurons (RN) and Index repeater F waves (Freps) were compared among the P, NP and control groups following 20 and 100 stimuli respectively. For each group, the Index RN and Index Freps obtained from 20 and 100 stimuli were compared. In the P group, the Index RN (P = 0.004) and Index Freps (P = 0.001) obtained from 100 stimuli were significantly higher than from 20 stimuli. For F waves obtained from 20 stimuli, no significant differences were identified between the P and NP groups for Index RN (P = 0.052) and Index Freps (P = 0.079); The Index RN (P waves obtained from 100 stimuli, the Index RN (P waves reflect increased excitability of motor neuron pool and indicate upper motor neuron dysfunction in ALS. For an accurate evaluation of repeater F waves in ALS patients especially those with moderate to severe muscle atrophy, 100 stimuli would be required.

  18. The levels of kerosene components in biological samples after repeated dermal exposure to kerosene in rats.

    Science.gov (United States)

    Fujihara, Junko; Hieda, Yoko; Tsujino, Yoshio; Xue, Yuying; Takayama, Koji; Kimura, Kojiro; Dekio, Satoshi

    2004-04-01

    The current study was experimentally investigated using rats whether or not kerosene components are accumulated from daily repeated dermal exposure. Rats received daily 1h-exposure to kerosene for 5 days (5K), daily 1h-exposure for 4 days and left for 1 day (4KL), a single 1h-exposure (1K), a single 1h-exposure and left for 1 day (1KL), or a single 1h-exposure, sacrificed and left dead for 1 day (1KLD). Kerosene components, trimethylbenzenes (TMBs) and aliphatic hydrocarbons (AHCs) in blood and tissues were determined by GC-MS. In blood, almost the same concentrations of TMBs were detected in the rats sacrificed immediately after exposure (5K, 1K and 1KLD), and only trace levels were detected in the rats sacrificed 1 day after exposure (4 and 1KL). Almost the same levels of AHCs in blood were detected among groups except for the rats sacrificed 1 day after a single exposure (1KL), in which AHCs were slightly lower. These results suggest that (1) AHCs tend to be accumulated from daily exposure, while TMBs do not, (2) the proportions of detected kerosene components in blood can be an indicator of whether the last exposure occurred just before death or not, (3) the kerosene levels last at least 1 day without blood circulation.

  19. Effects of storage conditions on forensic examinations of blood samples and bloodstains stored for 20 years.

    Science.gov (United States)

    Hara, M; Nakanishi, H; Yoneyama, K; Saito, K; Takada, A

    2016-01-01

    The effects of various storage conditions on blood identification tests, DNA degradation, and short tandem repeat (STR) typing were evaluated. Bloodstains stored at room temperature, 4 °C, -20 °C, and -80 °C for 20 years; blood samples stored at -20 °C and -80 °C for 20 years; and fresh blood samples were analyzed. Leuco-malachite-green testing, anti-human hemoglobin (Hb) testing (using immunochromatography), and tests for hemoglobin-beta (HBB) mRNA were performed as blood identification tests. DNA degradation was evaluated by quantifying the ratios of 305 and 129 base pair (bp) fragments to 41 bp fragments. STR typing was performed using an AmpFlSTR® Identifiler™ Plus PCR Amplification Kit. All samples were positive in leuco-malachite-green staining and anti-human Hb assays. HBB was not detected in blood samples stored at -20 °C or -80 °C, although this marker was detected in all bloodstains. As indicated by the ratio of 129:41 bp and 305:41 bp DNA fragments, DNA from bloodstains stored at room temperature or 4 °C were significantly degraded compared to DNA from all other samples. STR typing analyses revealed that a portion of the loci was undetected in bloodstains stored at room temperature. Therefore, to prevent DNA degradation during long-term storage, it is recommended that bloodstains and blood be stored at below -20 °C. In addition, because bloodstains are more suitable for detection of blood-specific mRNAs than blood sample, it is desirable that blood is stored as bloodstain for this method.

  20. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Ppressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  1. On the repeated measures designs and sample sizes for randomized controlled trials.

    Science.gov (United States)

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials.

  2. Importance of Sample Size for the Estimation of Repeater F Waves in Amyotrophic Lateral Sclerosis

    Directory of Open Access Journals (Sweden)

    Jia Fang

    2015-01-01

    Full Text Available Background: In amyotrophic lateral sclerosis (ALS, repeater F waves are increased. Accurate assessment of repeater F waves requires an adequate sample size. Methods: We studied the F waves of left ulnar nerves in ALS patients. Based on the presence or absence of pyramidal signs in the left upper limb, the ALS patients were divided into two groups: One group with pyramidal signs designated as P group and the other without pyramidal signs designated as NP group. The Index repeating neurons (RN and Index repeater F waves (Freps were compared among the P, NP and control groups following 20 and 100 stimuli respectively. For each group, the Index RN and Index Freps obtained from 20 and 100 stimuli were compared. Results: In the P group, the Index RN (P = 0.004 and Index Freps (P = 0.001 obtained from 100 stimuli were significantly higher than from 20 stimuli. For F waves obtained from 20 stimuli, no significant differences were identified between the P and NP groups for Index RN (P = 0.052 and Index Freps (P = 0.079; The Index RN (P < 0.001 and Index Freps (P < 0.001 of the P group were significantly higher than the control group; The Index RN (P = 0.002 of the NP group was significantly higher than the control group. For F waves obtained from 100 stimuli, the Index RN (P < 0.001 and Index Freps (P < 0.001 of the P group were significantly higher than the NP group; The Index RN (P < 0.001 and Index Freps (P < 0.001 of the P and NP groups were significantly higher than the control group. Conclusions: Increased repeater F waves reflect increased excitability of motor neuron pool and indicate upper motor neuron dysfunction in ALS. For an accurate evaluation of repeater F waves in ALS patients especially those with moderate to severe muscle atrophy, 100 stimuli would be required.

  3. Serine-Aspartate Repeat Protein D Increases Staphylococcus aureus Virulence and Survival in Blood

    Science.gov (United States)

    Uchiyama, Satoshi; Valderrama, J. Andrés; Ajayi, Clement; Sollid, Johanna U. E.; van Sorge, Nina M.; Nizet, Victor; van Strijp, Jos A. G.

    2016-01-01

    ABSTRACT Staphylococcus aureus expresses a panel of cell wall-anchored adhesins, including proteins belonging to the microbial surface components recognizing adhesive matrix molecule (MSCRAMM) family, exemplified by the serine-aspartate repeat protein D (SdrD), which serve key roles in colonization and infection. Deletion of sdrD from S. aureus subsp. aureus strain NCTC8325-4 attenuated bacterial survival in human whole blood ex vivo, which was associated with increased killing by human neutrophils. Remarkably, SdrD was able to inhibit innate immune-mediated bacterial killing independently of other S. aureus proteins, since addition of recombinant SdrD protein and heterologous expression of SdrD in Lactococcus lactis promoted bacterial survival in human blood. SdrD contributes to bacterial virulence in vivo, since fewer S. aureus subsp. aureus NCTC8325-4 ΔsdrD bacteria than bacteria of the parent strain were recovered from blood and several organs using a murine intravenous infection model. Collectively, our findings reveal a new property of SdrD as an important key contributor to S. aureus survival and the ability to escape the innate immune system in blood. PMID:27795358

  4. Evaluating venous pool technique for blood sampling in neonatal ICU.

    Science.gov (United States)

    Hatler, Carol; Dalton, Beverly; Day, Susan; Sharfner, Andrea; Hauffe, Rhonda

    2013-01-01

    To evaluate venous pool technique (VPT) for obtaining neonatal blood samples as compared with the needlestick technique. An experimental design was used with subjects enrolled in two phases: an equivalence phase (N = 10) and a comparison phase (N = 64). In the equivalence phase, subjects weighing 1,500 g or more had two needlesticks. In the comparison phase, subjects weighing 800 g or more were randomized to receive blood drawn by either needlestick method or VPT. Comparative results suggest that infant and maternal demographic factors, sampling attempts, and sampling failures were similar. However, for the outcome of hematoma development, the standard technique was significantly worse (t = 2.25 ; p = .029). Results suggest that the VPT method is safe and accurate for use in critically ill neonates. This study demonstrated that the VPT process is easily learned and may provide advantages over standard blood sampling methods. Nurses can use this information to evaluate this VPT technique in their institutions.

  5. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples.

    Science.gov (United States)

    Batterman, Stuart A; Chernyak, Sergey; Su, Feng-Chiao

    2016-01-01

    The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs) is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS). Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs), chlorinated hydrocarbons (CHCs), polychlorinated biphenyls (PCBs), and brominated diphenyl ethers (PBDEs). Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models. Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R (2) > 0.80), and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  6. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood and Dried Blood Spot Samples

    Directory of Open Access Journals (Sweden)

    Stuart A Batterman

    2016-04-01

    Full Text Available The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS. Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs, chlorinated hydrocarbons (CHCs, polychlorinated biphenyls (PCBs, and brominated diphenyl ethers (PBDEs. Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models.Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R2 > 0.80, and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  7. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  8. Simulation for clinical repeated-dose pharmacokinetic trials applying a peak-and-trough sampling design to estimate oral clearance.

    Science.gov (United States)

    Ishida, Kazuya; Kayano, Yuichiro; Taguchi, Masato; Hashimoto, Yukiya

    2007-11-01

    We performed a simulation for the clinical pharmacokinetic study, in which blood was sampled at two time points corresponding to the peak concentration (C(peak)) and trough concentration (C(trough)) following repetitive oral drug administration to subjects. We estimated the approximate oral clearance (CL/F(approx)) as 2.D/(C(peak).tau+C(trough).tau), where D is the dose, and tau is the dosing interval. The CL/F(approx) value was accurate for drugs with a long-elimination half-life, and the estimation error of the CL/F value was slightly increased for drugs with a shorter elimination half-life. The accuracy of CL/F(approx) in each subject was not affected by the magnitude of the interindividual pharmacokinetic variability, but was significantly decreased by the larger measurement error of drug concentrations (or intraindividual pharmacokinetic variability). We further performed several computer simulations to mimic statistical hypothesis testing following the clinical repeated-dose pharmacokinetic trials. The statistical power to detect the difference of oral clearance between two groups was marginally dependent on the measurement error of drug concentration, but was highly dependent on the interindividual pharmacokinetic variability. These findings suggested that the peak-and-trough sampling design to estimate the CL/F(approx) value is useful for clinical repeated-dose pharmacokinetic trials, and that the study design and protocol should be evaluated carefully by computer simulation prior to a real clinical trial.

  9. Blood haematological and biochemical parameters in normal cycling, pregnant and repeat breeding buffaloes (Bubalus bubalis) maintained in isothermic and isonutritional conditions

    Institute of Scientific and Technical Information of China (English)

    Anthony Sabasthin; Venkataswamy Girish Kumar; Sumanta Nandi

    2012-01-01

    Objective:The present study was envisaged to examine the hematological and biochemical, parameters in three different groups of buffaloes (regularly cycling, pregnant and repeat breeding) maintained in isothermic and isonutritional conditions to establish the variations in blood and/or serum components in these groups.Methods:Blood samples were analyzed for hemoglobin, PCV, TLC, neutophil, lymphocyte, eosinophil, and monocyte count, glucose, total protein, albumin, globulin, urea and cholesterol.Results:The results revealed significantly lower haemoglobin and packed cell volume value in repeat breeding when compared to pregnant and regularly cycling animals. The WBC value significantly higher in repeat breeding when compared to regularly cycling animals. The average mean values of neutrophils, lymphocyte and eosinophils revealed a no significant difference in the neutrophils, lymphocyte and eosinophils in between the group. The mean values of monocytes revealed a significantly higher value in repeat breeding animals when compared to pregnant animals. The serum glucose, total protein, cholesterol and urea levels were significantly lower in repeat breeding compared to pregnant and regularly cycling animals. The levels of albumin and globulin revealed non-significant difference among the groups.Conclusions: A significant decrease in the hemoglobin, PCV, glucose, total protein, cholesterol and urea was observed in the repeat breeding animals when compared to pregnant and regularly cycling animals.

  10. Population data on 6 short tandem repeat loci in a sample of Caucasian-Mestizos from Colombia.

    Science.gov (United States)

    Yunis, J J; García, O; Uriarte, I; Yunis, E J

    2000-01-01

    Blood samples from 409-452 unrelated Colombian Caucasian-Mestizo individuals were amplified and typed for six short tandem repeat (STR) markers (HUMF13A01, HUMFES/FPS, HUMVWA, HUMCSF1PO, HUMTPOX, HUMTH01). The allele frequencies, genotype frequencies, heterozygosity, mean paternity exclusion chance, polymorphism information content, discrimination power, assumption of independence within and between loci and Hardy Weinberg equilibrium were determined. The results demonstrate that all markers conform to Hardy-Weinberg equilibrium expectations. In addition, the results demonstrate the assumption of independence within and between the loci analysed. The mean exclusion chance (MEC) was 0.9851 for all six STR loci analysed and the discrimination power (DP) was 0.9999973. Therefore, this Colombian population database can be used in identity testing to estimate the frequency of a multiple PCR-based locus DNA profile in forensic cases as well as in paternity testing.

  11. Repeated injection of PEGylated solid lipid nanoparticles induces accelerated blood clearance in mice and beagles

    Directory of Open Access Journals (Sweden)

    Zhao Y

    2012-06-01

    Full Text Available Yongxue Zhao, Long Wang, Mina Yan, Yanling Ma, Guangxi Zang, Zhennan She, Yihui DengCollege of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning, People’s Republic of ChinaAbstract: Surface modification of nanocarriers with amphiphilic polymer polyethylene glycol (PEG, known as PEGylation, is regarded as a major breakthrough in the application of nanocarriers. However, PEGylated nanocarriers (including liposomes and polymeric nanoparticles induce what is referred to as the “accelerated blood clearance (ABC phenomenon” upon repeated injection and consequently they lose their sustained circulation characteristics. Despite this, the present authors are not aware of any reports of accelerated clearance due to repeated injection for PEGylated solid lipid nanoparticles (SLNs, another promising nanocarrier. This study investigated the pharmacokinetics of PEGylated SLNs upon repeated administration in mice; moreover, the impact of circulation time on the induction of the ABC phenomenon was studied in beagles for the first time. The ABC index, selected as the ratio of the area under the concentration-time curve from time 0 to the last measured concentration of a second injection to that of the first injection, was used to evaluate the extent of this phenomenon. Results showed that the PEGylated SLNs exhibited accelerated clearance from systemic circulation upon repeated injection, both in mice and in beagles, and the ratio for the different time intervals, which showed that the ABC index exhibited significant difference within 30 minutes following the second injection, was good enough to evaluate the magnitude of ABC. This ABC index indicated that the 10 mol% PEG SLNs with a suitable prolonged circulation time induced the most marked ABC phenomenon in this research. This study demonstrated that, like PEGylated nanocarriers such as liposomes and polymeric nanoparticles, PEGylated SLNs induced the ABC phenomenon upon repeated injection

  12. Safety Validation of Repeated Blood-Brain Barrier Disruption Using Focused Ultrasound.

    Science.gov (United States)

    Kobus, Thiele; Vykhodtseva, Natalia; Pilatou, Magdalini; Zhang, Yongzhi; McDannold, Nathan

    2016-02-01

    The purpose of this study was to investigate the effects on the brain of multiple sessions of blood-brain barrier (BBB) disruption using focused ultrasound (FUS) in combination with micro-bubbles over a range of acoustic exposure levels. Six weekly sessions of FUS, using acoustical pressures between 0.66 and 0.80 MPa, were performed under magnetic resonance guidance. The success and degree of BBB disruption was estimated by signal enhancement of post-contrast T1-weighted imaging of the treated area. Histopathological analysis was performed after the last treatment. The consequences of repeated BBB disruption varied from no indications of vascular damage to signs of micro-hemorrhages, macrophage infiltration, micro-scar formations and cystic cavities. The signal enhancement on the contrast-enhanced T1-weighted imaging had limited value for predicting small-vessel damage. T2-weighted imaging corresponded well with the effects on histopathology and could be used to study treatment effects over time. This study demonstrates that repeated BBB disruption by FUS can be performed with no or limited damage to the brain tissue.

  13. From clinical sites to biorepositories: effectiveness in blood sample management.

    Science.gov (United States)

    Lefebvre, Céline; Tremblay, Nancy; Iverson, Bonnie; Wong, David; McWeeny, Kerri; Saghbini, Michael; Martinez, Heather; Hogan, Michael; Gaudet, Daniel; Arsenault, Steve

    2010-12-01

    Today's biobanks must work to take full advantage of collected samples, while maximizing sample quality and minimizing costs to sustain operations for a long period of time. This is a tall order that will require collaboration and compromise for both end-users and collection sites. This article discusses the efforts of the Génome Québec-Centre Hospitalier Affilié Universitaire Régional de Chicoutimi Biobank to fractionate blood samples for the simultaneous preservation of plasma and DNA-containing layers while minimizing resources required for shipping and transport. This article also describes methods for successful reproducible application of the plasma-depleted blood sample to GenPlates (GenVault, Carlsbad, CA).

  14. Quantification of multiple elements in dried blood spot samples

    DEFF Research Database (Denmark)

    Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads;

    2017-01-01

    BACKGROUND: Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. METHODS: Elements were...... extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations...... in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. RESULTS: The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K...

  15. Importance of Sample Size for the Estimation of Repeater F Waves in Amyotrophic Lateral Sclerosis

    Institute of Scientific and Technical Information of China (English)

    Jia Fang; Ming-Sheng Liu; Yu-Zhou Guan; Bo Cui; Li-Ying Cui

    2015-01-01

    Background:In amyotrophic lateral sclerosis (ALS),repeater F waves are increased.Accurate assessment of repeater F waves requires an adequate sample size.Methods:We studied the F waves of left ulnar nerves in ALS patients.Based on the presence or absence of pyramidal signs in the left upper limb,the ALS patients were divided into two groups:One group with pyramidal signs designated as P group and the other without pyramidal signs designated as NP group.The Index repeating neurons (RN) and Index repeater F waves (Freps) were compared among the P,NP and control groups following 20 and 100 stimuli respectively.For each group,the Index RN and Index Freps obtained from 20 and 100 stimuli were compared.Results:In the P group,the Index RN (P =0.004) and Index Freps (P =0.001) obtained from 100 stimuli were significantly higher than from 20 stimuli.For F waves obtained from 20 stimuli,no significant differences were identified between the P and NP groups for Index RN (P =0.052) and Index Freps (P =0.079); The Index RN (P < 0.001) and Index Freps (P < 0.001) of the P group were significantly higher than the control group; The Index RN (P =0.002) of the NP group was significantly higher than the control group.For F waves obtained from 100 stimuli,the Index RN (P < 0.001) and Index Freps (P < 0.001) of the P group were significantly higher than the NP group; The Index RN (P < 0.001) and Index Freps (P < 0.001) of the P and NP groups were significantly higher than the control group.Conclusions:Increased repeater F waves reflect increased excitability of motor neuron pool and indicate upper motor neuron dysfunction in ALS.For an accurate evaluation of repeater F waves in ALS patients especially those with moderate to severe muscle atrophy,100 stimuli would be required.

  16. Impact of repeated measures and sample selection on genome-wide association studies of fasting glucose

    Science.gov (United States)

    Rasmussen-Torvik, Laura J.; Alonso, Alvaro; Li, Man; Kao, Wen; Köttgen, Anna; Yan, Yuer; Couper, David; Boerwinkle, Eric; Bielinski, Suzette J.; Pankow, James S.

    2010-01-01

    Although GWAS have been performed in longitudinal studies, most used only a single trait measure. GWAS of fasting glucose have generally included only normoglycemic individuals. We examined the impact of both repeated measures and sample selection on GWAS in ARIC, a study which obtained four longitudinal measures of fasting glucose and included both individuals with and without prevalent diabetes. The sample included Caucasians and the Affymetrix 6.0 chip was used for genotyping. Sample sizes for GWAS analyses ranged from 8372 (first study visit) to 5782 (average fasting glucose). Candidate SNP analyses with SNPs identified through fasting glucose or diabetes GWAS were conducted in 9133 individuals, including 761 with prevalent diabetes. For a constant sample size, smaller p-values were obtained for the average measure of fasting glucose compared to values at any single visit, and two additional significant GWAS signals were detected. For four candidate SNPs (rs780094, rs10830963, rs7903146, and rs4607517), the strength of association between genotype and glucose was significantly (p-interaction fasting glucose candidate SNPs (rs780094, rs10830963, rs560887, rs4607517, rs13266634) the association with measured fasting glucose was more significant in the smaller sample without prevalent diabetes than in the larger combined sample of those with and without diabetes. This analysis demonstrates the potential utility of averaging trait values in GWAS studies and explores the advantage of using only individuals without prevalent diabetes in GWAS of fasting glucose. PMID:20839289

  17. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  18. Novel genotype of Ehrlichia canis detected in samples of human blood bank donors in Costa Rica.

    Science.gov (United States)

    Bouza-Mora, Laura; Dolz, Gaby; Solórzano-Morales, Antony; Romero-Zuñiga, Juan José; Salazar-Sánchez, Lizbeth; Labruna, Marcelo B; Aguiar, Daniel M

    2017-01-01

    This study focuses on the detection and identification of DNA and antibodies to Ehrlichia spp. in samples of blood bank donors in Costa Rica using molecular and serological techniques. Presence of Ehrlichia canis was determined in 10 (3.6%) out of 280 blood samples using polymerase chain reaction (PCR) targeting the ehrlichial dsb conserved gene. Analysis of the ehrlichial trp36 polymorphic gene in these 10 samples revealed substantial polymorphism among the E. canis genotypes, including divergent tandem repeat sequences. Nucleotide sequences of dsb and trp36 amplicons revealed a novel genotype of E. canis in blood bank donors from Costa Rica. Indirect immunofluorescence assay (IFA) detected antibodies in 35 (35%) of 100 serum samples evaluated. Thirty samples showed low endpoint titers (64-256) to E. canis, whereas five sera yielded high endpoint titers (1024-8192); these five samples were also E. canis-PCR positive. These findings represent the first report of the presence of E. canis in humans in Central America.

  19. Impact of blood sampling in very preterm infants

    DEFF Research Database (Denmark)

    Madsen, L P; Rasmussen, M K; Bjerregaard, L L;

    2000-01-01

    In a prospective investigation, 99 very preterm infants (gestational age (GA) 24 32 weeks, birthweight 560-2,255 g) were studied during the first 4 weeks of life. The infants were divided into two groups: infants born extremely early (GA <28 weeks, n = 20) and infants of GA 28 - 32 weeks; the gro......In a prospective investigation, 99 very preterm infants (gestational age (GA) 24 32 weeks, birthweight 560-2,255 g) were studied during the first 4 weeks of life. The infants were divided into two groups: infants born extremely early (GA ... low GA received 28 blood transfusions, corresponding to 27.0 ml/kg of blood on average during the study period. Four developed late anaemia; thus, in total, 14 (70%) of the infants born extremely early received 35 transfusions during the first 3 months of life, corresponding to a total mean of 34.8 ml....../kg. For the extremely preterm infants a significant correlation between sampled and transfused blood volume was found (mean 37.1 and 33.3 ml/kg, respectively, r = + 0.71, p = 0.0003). The most frequently requested analyses were glucose, sodium and potassium. Few blood gas analyses were requested (1.9/ infant). No blood...

  20. Microbiosensors for determination of glucose in the blood sample

    Institute of Scientific and Technical Information of China (English)

    金鹏; 谭久彬; 孙凯

    2002-01-01

    Describes the general design of Microbiosensors for determination of glucose in blood sample for medical purpose as an important branch of medical analysis instrument discusses the fabrication of microbiosensors. By the technology of microfabrication, self-assembled monolayers (SAMs) and enzyme immobilization, stresses their properties, such as improvement in system efficiency, shorter analysis time reduction of reagent waste and reduction of device sizes, which makes them suitable for bed-side monitor of emergency patients.

  1. ECCM scheme against interrupted sampling repeater jammer based on time-frequency analysis

    Institute of Scientific and Technical Information of China (English)

    Shixian Gong; Xizhang Wei; Xiang Li

    2014-01-01

    The interrupted sampling repeater jamming (ISRJ) is an effective deception jamming method for coherent radar, especial y for the wideband linear frequency modulation (LFM) radar. An electronic counter-countermeasure (ECCM) scheme is proposed to remove the ISRJ-based false targets from the pulse compres-sion result of the de-chirping radar. Through the time-frequency (TF) analysis of the radar echo signal, it can be found that the TF characteristics of the ISRJ signal are discontinuous in the pulse duration because the ISRJ jammer needs short durations to re-ceive the radar signal. Based on the discontinuous characteristics a particular band-pass filter can be generated by two alternative approaches to retain the true target signal and suppress the ISRJ signal. The simulation results prove the validity of the proposed ECCM scheme for the ISRJ.

  2. Appropriate timing of blood sampling for blood gas analysis in the ventilated rabbit.

    Science.gov (United States)

    Sei, Kiguna; Fujita, Masanori; Okawa, Shinpei; Hirasawa, Takeshi; Kushibiki, Toshihiro; Sasa, Hidenori; Furuya, Kenichi; Ishihara, Miya

    2016-12-01

    Arterial and venous blood gas analyses (BGAs) are essential to evaluate devices that measure biological oxygenation. The appropriate timing of blood sampling for BGA after respiratory rate (RR) change in animal experiments has not been reported. This study investigated the appropriate timing of blood sampling for BGA in ventilated rabbits and whether venous samples are an alternative to arterial samples. Under general anesthesia, 14 rabbits (body weight, 3.02 ± 0.09 kg) were ventilated and their RR was changed (40/min, 30/min, and 20/min). Blood was sampled through cervical arterial and venous catheters. Experiment 1: in seven rabbits, arterial BGA was measured at 0, 0.5, 1, 2, 3, 5, 10, 15, and 20 min after the RR change. Experiment 2: in seven different rabbits, simultaneous arterial and venous BGA were measured at 0, 2, 5, 10, 15, and 20 min after the RR change. Oxygen partial pressure (PO2) and saturation (SO2) of the arterial blood stabilized 0.5 min after the RR changed. In venous BGA, no index stabilized during observation. The arterial and venous values of the carbon dioxide partial pressure (PCO2) and pH had significant correlations (arterial PCO2 = 0.9316 × venous PCO2-4.4425 [r = 0.9178]; arterial pH = 1.0835 × venous pH-0.5795 [r = 0.9453]). In ventilated rabbits, arterial PO2 and SO2 stabilized in 0.5 min. No venous value stabilized after the RR change. Only the PCO2 and pH of venous samples may be an alternative to arterial samples under the defined formula. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  3. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  4. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  5. Nanoliter viscometer for analyzing blood plasma and other liquid samples.

    Science.gov (United States)

    Srivastava, Nimisha; Davenport, Robertson D; Burns, Mark A

    2005-01-15

    We have developed a microfabricated nanoliter capillary viscometer that quickly, easily, and inexpensively measures the viscosity of liquids. The measurement of viscosity is based on capillary pressure-driven flow inside microfluidic channels (depth approximately 30 microm and width approximately 300 microm). Accurate and precise viscosity measurements can be made in less than 100 s while using only 600 nL of liquid sample. The silicon-glass hybrid device (18 mm by 15 mm) contains on-chip components that measure the driving capillary pressure difference and the relevant geometrical parameters; these components make the nanoliter viscometer completely self-calibrating, robust, and easy to use. Several different microfabricated viscometers were tested using solutions with viscosities ranging from 1 to 5 cP, a range relevant to biological fluids (urine, blood, blood plasma, etc.). Blood plasma samples collected from patients with the symptoms of hyperviscosity syndrome were tested on the nanoliter capillary viscometer to an accuracy of 3%. Such self-calibrating nanoliter viscometers may have widespread applications in chemical, biological, and medical laboratories as well as in personal health care.

  6. Experience of fetal scalp blood sampling during labor.

    Science.gov (United States)

    Liljeström, Lena; Wikström, Anna-Karin; Skalkidou, Alkistis; Akerud, Helena; Jonsson, Maria

    2014-01-01

    Fetal scalp blood sampling (FBS) is often claimed to be painful for women in labor and difficult for obstetricians to perform. Our aim was to assess women's experience of pain during FBS and obstetricians' experience of difficulty in performing the test. At a tertiary center in Sweden, a questionnaire with answers on a 10-point scale was completed by 51 women and the obstetricians performing the test. Women's experience of pain had a median of 3.5. FBS was well tolerated in women who had epidural analgesia but might be associated with pain in women without. Higher maternal body mass index and less cervical dilation were associated with higher pain ratings. Obstetricians did not generally experience scalp sampling as difficult to perform (median score 3.0). However, the sampling procedure can be more complicated in situations with higher maternal body mass index, less cervical dilation, and a higher station of the fetal head.

  7. Diagnostic fetal umbilical blood sampling in the management of isoimmunization.

    Science.gov (United States)

    Reece, E A; Copel, J A; Scioscia, A L; Grannum, P A; DeGennaro, N; Hobbins, J C

    1988-11-01

    Current management of isoimmunization in pregnancy is predicted on the assumption that all sensitized women carry antigen-positive fetuses. In addition, management is based on indirect predictors of the magnitude of the fetal hemolytic disease. We present a preliminary report using a new approach of direct fetal blood sampling for the diagnosis and treatment of these patients. This form of evaluation provides specific information about fetal red blood cell antigen status and the degree of fetal anemia at an earlier gestational age than that validated by the Liley curves and eliminates empiricism from both the diagnosis and treatment of the isoimmunized pregnancy. The use of such a management protocol reduces the need for multiple invasive procedures in fetuses at little risk for disease and provides specific information about the status of those fetuses truly at risk.

  8. Fetal scalp blood sampling in labor - a review

    DEFF Research Database (Denmark)

    Jørgensen, Jan Stener; Weber, Tom

    2014-01-01

    During the 1970s and 1980s, electronic fetal monitoring and fetal scalp blood sampling (FBS) were introduced without robust evidence. With a methodical review of the published literature, and using one randomized controlled trial, seven controlled studies, nine randomized studies of various...... surveillance methods and data from the Danish National Birth Registry, we have assessed the usefulness of FBS as a complementary tool to improve the specificity and sensitivity of electronic cardiotocography (CTG). Based on heterogeneous studies of modest quality with somewhat inconsistent results, we conclude...

  9. Impact of blood sampling in very preterm infants

    DEFF Research Database (Denmark)

    Madsen, L P; Rasmussen, M K; Bjerregaard, L L

    2000-01-01

    In a prospective investigation, 99 very preterm infants (gestational age (GA) 24 32 weeks, birthweight 560-2,255 g) were studied during the first 4 weeks of life. The infants were divided into two groups: infants born extremely early (GA <28 weeks, n = 20) and infants of GA 28 - 32 weeks; the gro......In a prospective investigation, 99 very preterm infants (gestational age (GA) 24 32 weeks, birthweight 560-2,255 g) were studied during the first 4 weeks of life. The infants were divided into two groups: infants born extremely early (GA .../kg. For the extremely preterm infants a significant correlation between sampled and transfused blood volume was found (mean 37.1 and 33.3 ml/kg, respectively, r = + 0.71, p = 0.0003). The most frequently requested analyses were glucose, sodium and potassium. Few blood gas analyses were requested (1.9/ infant). No blood...... in extremely preterm, critically ill infants. Udgivelsesdato: 2000-Apr...

  10. Involvement of Inflammation and Adverse Vascular Remodelling in the Blood Pressure Raising Effect of Repeatedly Heated Palm Oil in Rats

    Directory of Open Access Journals (Sweden)

    Chun-Yi Ng

    2012-01-01

    Full Text Available Oil thermoxidation during deep frying generates harmful oxidative free radicals that induce inflammation and increase the risk of hypertension. This study aimed to investigate the effect of repeatedly heated palm oil on blood pressure, aortic morphometry, and vascular cell adhesion molecule-1 (VCAM-1 expression in rats. Male Sprague-Dawley rats were divided into five groups: control, fresh palm oil (FPO, one-time-heated palm oil (1HPO, five-time-heated palm oil (5HPO, or ten-time-heated palm oil (10HPO. Feeding duration was six months. Blood pressure was measured at baseline and monthly using tail-cuff method. After six months, the rats were sacrificed and the aortic arches were dissected for morphometric and immunohistochemical analyses. FPO group showed significantly lower blood pressure than all other groups. Blood pressure was increased significantly in 5HPO and 10HPO groups. The aortae of 5HPO and 10HPO groups showed significantly increased thickness and area of intima-media, circumferential wall tension, and VCAM-1 than other groups. Elastic lamellae were disorganised and fragmented in 5HPO- and 10HPO-treated rats. VCAM-1 expression showed a significant positive correlation with blood pressure. In conclusion, prolonged consumption of repeatedly heated palm oil causes blood pressure elevation, adverse remodelling, and increased VCAM-1, which suggests a possible involvement of inflammation.

  11. Toxoplasma polymerase chain reaction on experimental blood samples.

    Science.gov (United States)

    Joss, A W; Chatterton, J M; Evans, R; Ho-Yen, D O

    1993-01-01

    A two-stage polymerase chain reaction (PCR) assay employing oligonucleotide primers from the B1 gene of Toxoplasma gondii was developed and assessed for sensitivity and specificity. It was able to detect T. gondii DNA from as little as one parasite/sample in mock-infected rat or mouse leucocyte preparations. Parasitaemia was also identified in animals at five stages between 16 and 66 h after infection with the virulent RH strain, and at 12 stages between 2 and 38 days after infection with the cyst-forming Beverley strain. In the latter case, PCR was more sensitive than animal culture. No cross-reactions were observed in samples containing various opportunist pathogens which may also be found in the blood of immunocompromised patients.

  12. High plasma corticosterone levels persist during frequent automatic blood sampling in rats

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Adem, Bashir; Royo, Felix

    2005-01-01

    Corticosterone levels in blood may be used as a marker of stress in rodents, provided that the blood sampling procedure itself is non-stressful. Automated blood sampling equipment (Accusampler) allows blood sampling without any interference with the animal and might be useful as a tool for an on...... the importance of considering the frequency of blood withdrawal during automated blood sampling. This parameter may have an impact on the experimental results when using blood corticosterone levels as a stress marker, but also during any in vivo study where blood is collected, since high corticosterone levels...... may affect the normal physiology of the animals....

  13. On the improvement of blood sample collection at clinical laboratories

    Science.gov (United States)

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  14. Prevention of hemolysis in blood samples collected from intravenous catheters.

    Science.gov (United States)

    Lippi, Giuseppe; Avanzini, Paola; Cervellin, Gianfranco

    2013-05-01

    Samples drawn through intravenous catheters are frequently hemolyzed. We planned a prospective, randomized study to establish whether hemolysis in samples drawn from intravenous catheters may be reduced using S-Monovette® tubes collected by manual aspiration as compared with standard vacuum tubes. We studied 52 consecutive patients admitted to the ED. Blood was drawn through a 20-gauge intravenous catheter. A 5.0mL, Becton Dickinson Vacutainer® SST II Plus serum tube was collected and discarded. In the odd group of patients (i.e., n. 1, 3, 5, etc.), a second SST II tube was drawn with vacuum ("BD-V"), followed by a 5.5mL S-Monovette® serum tube collected with manual aspiration ("SD-A") and an identical S-Monovette collected by vacuum ("SD-V"). In the pair group of patients (i.e., n. 2, 4, 6, etc.), the sequence was modified to "SD-A", "SD-V" and "BD-V". Serum was separated and tested for lactate dehydrogenase (LDH), potassium and cell-free hemoglobin. The mean concentration of potassium (+2.7% in BD-V and +1.7% in SD-V, respectively), LDH (+15% in BD-V and +7% in SD-V, respectively) and cell-free hemoglobin was significantly increased when samples were collected with vacuum tubes as compared with manual aspiration. No significant differences were observed between SD-V and BD-V. The frequency of hemolyzed samples was higher when blood was collected with the vacuum as compared with SD-A (i.e., 2%), but did not differ between BD-V and SD-V (i.e., 29 versus 31%; p=0.70). S-Monovette can be used with vacuum or aspiration collection. This latter approach allows blood drawing with limited shear stress and less likelihood of generating spuriously hemolysis. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Sampling and storage conditions influencing the measurement of parathyroid hormone in blood samples: a systematic review.

    Science.gov (United States)

    Hanon, Elodie A; Sturgeon, Catharine M; Lamb, Edmund J

    2013-10-01

    Parathyroid hormone (PTH) is relatively unstable: optimisation of pre-analytical conditions, including specimen type, sampling time and storage conditions, is essential. We have undertaken a systematic review of these pre-analytical conditions. An electronic search of the PubMed, Embase, Cochrane, Centre for Research and Dissemination and Bandolier databases was undertaken. Of 5511 papers identified, 96 underwent full text review, of which 83 were finally included. At room temperature PTH was stable in ethylenediaminetetraacetic acid (EDTA) preserved whole blood for at least 24 h and in EDTA plasma for at least 48 h after venepuncture. Losses were observed in clotted blood samples after 3 h and in serum after 2 h. At 4°C PTH was more stable in EDTA plasma (at least 72 h) than serum (at least 24 h). Central venous PTH concentrations were higher than peripheral venous concentrations. In the northern hemisphere, PTH concentrations were higher in winter than summer. PTH has a circadian rhythm characterised by a nocturnal acrophase and mid-morning nadir. Data related to frozen storage of PTH (-20°C and -80°C) were limited and contradictory. We recommend that blood samples for PTH measurement should be taken into tubes containing EDTA, ideally between 10:00 and 16:00, and plasma separated within 24 h of venepuncture. Plasma samples should be stored at 4°C and analysed within 72 h of venepuncture. Particular regard must be paid to the venepuncture site when interpreting PTH concentration. Further research is required to clarify the suitability of freezing samples prior to PTH measurement.

  16. Effect of the number of sprint repetitions on the variation of blood lactate concentration in repeated sprint sessions.

    Science.gov (United States)

    Gharbi, Z; Dardouri, W; Haj-Sassi, R; Castagna, C; Chamari, K; Souissi, N

    2014-06-01

    The aim of the present study was to examine the effect of number of sprint repetitions on the variation of blood lactate concentration (blood [La]) during different repeated-sprint sessions in order to find the appropriate number of sprint repetitions that properly simulates the physiological demands of team sport competitions. Twenty male team-sport players (age, 22.2 ± 2.9 years) performed several repeated-sprint sessions (RSS) consisting of 1, 2, 3, 4, 5, 9, or 10 repetitions of 30 m shuttle sprints (2 × 15 m) with 30 s recovery in between. The blood [La] was obtained after 3 min of recovery at the end of each RSS. The present study showed that for RSS of 3 sprints (RSS3) there was a high increase (psprints (9.6±1.4 and 10.5±1.9 mmol · l(-1), p=0.96 and 0.26, respectively). After RSS9 and RSS10 blood [La] further significantly increased to 12.6 and 12.7 mmol · l(-1), psprint speed decrement (Sdec) (1.5±1.2; 2.0±1.1 and 2.6±1.4%, respectively). There was also no significant difference between RSS9 and RSS10 for Sdec (3.9±1.3% and 4.5±1.4%, respectively). In conclusion, the repeated-sprint protocol composed of 5 shuttle sprint repetitions is more representative of the blood lactate demands of the team sports game intensity.

  17. Natural Antioxidants Improve Red Blood Cell “Survival” in Non-Leukoreduced Blood Samples

    Directory of Open Access Journals (Sweden)

    Yuliya V Kucherenko

    2015-03-01

    Full Text Available Background: Blood collected in an anticoagulant can be kept refrigerated in an unmodified state within 5 - 6 weeks. Oxidative damage is considered to be a one of the major factors contributing to the development of storage lesions. Lipid and membrane proteins oxidation results in changes in cation gradients that affect the cell survival. Aim: In the present study we used the natural antioxidants and ion channels blockers (L-carnosine, spermine, phloretin and their mixtures to prolong “survival” of red blood cells (RBCs, measured as the lack of PS exposure and cell hemolysis, in the Alsever's preservative solution upon hypothermic storage. Results: We show that the mixture of carnosine (20 mM, spermine (20 µM and phloretin (100 µM effectively blunted phosphatidylserine (PS exposure, Ca2+ accumulation and RBCs hemolysis in non-leukoreduced low (∼2% hematocrit samples after 36 days of storage as well as after 1 day of post-storage incubation of the stored cells in physiological saline solution. In addition, a slight but significant decrease in PS exposure was observed in non-leukoreduced high (∼20% hematocrit samples after 36 days of storage with the mixture of substances. Conclusion: We conclude that the use of the mixture of natural antioxidants (carnosine, spermine, and phloretin as an additive to blood preservative solution provides better RBCs storage and “survival”.

  18. A pool of repeat blood donors can be generated with little expense to the blood center in sub-Saharan Africa.

    Science.gov (United States)

    Allain, Jean-Pierre; Sarkodie, Francis; Boateng, Peter; Asenso, Kwame; Kyeremateng, Ernest; Owusu-Ofori, Shirley

    2008-04-01

    In sub-Saharan Africa, most collected blood originates from accessible and cheaper replacement donors while recruiting and retaining volunteers requires considerable costs not all countries can afford. The Kumasi Teaching Hospital Blood Center and a local FM radio station developed a partnership calling three times a year for donation at the radio station where music, entertainment, and token gifts were available. To assess the program's impact, attendance, deferral, age, sex, identification, and viral test results of donors attending 12 consecutive sessions in 2003 through 2006 were analyzed, and this donor population was compared to other types of donors in Kumasi, Ghana. A total of 3801 donors attended the program and 92 percent of the potential FM donors were eligible to donate compared to 85.5 and 70.3 percent of other volunteer and replacement donors, respectively. Ninety percent of donors were male (median, 25 years) and 4.9 percent were hepatitis B surface antigen-positive compared to 11 and 15 percent in other volunteer and replacement donors. This reflected 63.6 percent spontaneous repeat donations from donors responding to the radio appeal compared to 15 to 30 percent in other volunteer donors. It has been demonstrated that the use of a culturally and socially adapted environment to make the gift of blood a pleasurable and festive experience generated a new pool of blood donors spontaneously repeating donations. This program indicates that retaining Ghanaian blood donors is possible at little extra cost to the blood center and that such an approach may represent a substantial help in the efforts of sub-Saharan Africa to collect volunteer blood.

  19. Virgin Coconut Oil Prevents Blood Pressure Elevation and Improves Endothelial Functions in Rats Fed with Repeatedly Heated Palm Oil

    Directory of Open Access Journals (Sweden)

    Badlishah Sham Nurul-Iman

    2013-01-01

    Full Text Available This study was performed to explore the effects of virgin coconut oil (VCO in male rats that were fed with repeatedly heated palm oil on blood pressure, plasma nitric oxide level, and vascular reactivity. Thirty-two male Sprague-Dawley rats were divided into four groups: (i control (basal diet, (ii VCO (1.42 mL/kg, oral, (iii five-times-heated palm oil (15% (5HPO, and (iv five-times-heated palm oil (15% and VCO (1.42 mL/kg, oral (5HPO + VCO. Blood pressure was significantly increased in the group that was given the 5HPO diet compared to the control group. Blood pressure in the 5HPO + VCO group was significantly lower than the 5HPO group. Plasma nitric oxide (NO level in the 5HPO group was significantly lower compared to the control group, whereas in the 5HPO + VCO group, the plasma NO level was significantly higher compared to the 5HPO group. Aortic rings from the 5HPO group exhibited attenuated relaxation in response to acetylcholine and sodium nitroprusside as well as increased vasoconstriction to phenylephrine compared to the control group. Aortic rings from the 5HPO + VCO group showed only attenuated vasoconstriction to phenylephrine compared to the 5HPO group. In conclusion, VCO prevents blood pressure elevation and improves endothelial functions in rats fed with repeatedly heated palm oil.

  20. Virgin coconut oil prevents blood pressure elevation and improves endothelial functions in rats fed with repeatedly heated palm oil.

    Science.gov (United States)

    Nurul-Iman, Badlishah Sham; Kamisah, Yusof; Jaarin, Kamsiah; Qodriyah, Hj Mohd Saad

    2013-01-01

    This study was performed to explore the effects of virgin coconut oil (VCO) in male rats that were fed with repeatedly heated palm oil on blood pressure, plasma nitric oxide level, and vascular reactivity. Thirty-two male Sprague-Dawley rats were divided into four groups: (i) control (basal diet), (ii) VCO (1.42 mL/kg, oral), (iii) five-times-heated palm oil (15%) (5HPO), and (iv) five-times-heated palm oil (15%) and VCO (1.42 mL/kg, oral) (5HPO + VCO). Blood pressure was significantly increased in the group that was given the 5HPO diet compared to the control group. Blood pressure in the 5HPO + VCO group was significantly lower than the 5HPO group. Plasma nitric oxide (NO) level in the 5HPO group was significantly lower compared to the control group, whereas in the 5HPO + VCO group, the plasma NO level was significantly higher compared to the 5HPO group. Aortic rings from the 5HPO group exhibited attenuated relaxation in response to acetylcholine and sodium nitroprusside as well as increased vasoconstriction to phenylephrine compared to the control group. Aortic rings from the 5HPO + VCO group showed only attenuated vasoconstriction to phenylephrine compared to the 5HPO group. In conclusion, VCO prevents blood pressure elevation and improves endothelial functions in rats fed with repeatedly heated palm oil.

  1. A Cross-Sectional Study on the Perceptions and Practices of Teenagers With Inflammatory Bowel Disease About Repeated Stool Sampling

    NARCIS (Netherlands)

    Heida, Anke; Dijkstra, Alie; Dantuma, Sietske K.; van Rheenen, Patrick F.

    2016-01-01

    Purpose: Repeated stool sampling to monitor disease activity is increasingly used in teenagers with inflammatory bowel disease (IBD). Knowledge about their perceptions and practices regarding collection of feces will increase the success rate of this monitoring strategy. Methods: We sent a survey to

  2. Methane hydrate distribution from prolonged and repeated formation in natural and compacted sand samples: X-ray CT observations

    Energy Technology Data Exchange (ETDEWEB)

    Rees, E.V.L.; Kneafsey, T.J.; Seol, Y.

    2010-07-01

    To study physical properties of methane gas hydrate-bearing sediments, it is necessary to synthesize laboratory samples due to the limited availability of cores from natural deposits. X-ray computed tomography (CT) and other observations have shown gas hydrate to occur in a number of morphologies over a variety of sediment types. To aid in understanding formation and growth patterns of hydrate in sediments, methane hydrate was repeatedly formed in laboratory-packed sand samples and in a natural sediment core from the Mount Elbert Stratigraphic Test Well. CT scanning was performed during hydrate formation and decomposition steps, and periodically while the hydrate samples remained under stable conditions for up to 60 days. The investigation revealed the impact of water saturation on location and morphology of hydrate in both laboratory and natural sediments during repeated hydrate formations. Significant redistribution of hydrate and water in the samples was observed over both the short and long term.

  3. Quantification of print, radio and television exposure among previous blood donors in Kenya: an opportunity for encouraging repeat donation in a resource-limited setting?

    Science.gov (United States)

    Basavaraju, S V; Mwangi, J; Kellogg, T A; Odawo, L; Marum, L H

    2010-10-01

    Blood services in sub-Saharan Africa experience blood shortages and low retention of voluntary, non-remunerated donors. To boost collections by encouraging repeat donations, the Kenya National Blood Transfusion Service is exploring the likelihood of reaching previous donors through targeted print, radio and television advertising. We analysed data from a national AIDS Indicator Survey to determine whether previous donors have significant exposure to media. Respondents reporting history of blood donation had significantly higher exposure to print, radio and television media than those without history of blood donation. Targeted media campaigns encouraging repeat donation are likely to reach previous donors even in resource-limited settings.

  4. A modified serial blood sampling technique and utility of dried-blood spot technique in estimation of blood concentration: application in mouse pharmacokinetics.

    Science.gov (United States)

    Kurawattimath, Vishwanath; Pocha, Krishna; Mariappan, T Thanga; Trivedi, Ravi Kumar; Mandlekar, Sandhya

    2012-03-01

    Pharmacokinetic (PK) studies in mice usually require discrete and parallel blood sampling owing to a restriction on the volume of blood that can be withdrawn. This results in dosing large number of animals and generating composite PK profile. To reduce the number of animals and generate individual animal PK profiles, we developed a serial sampling technique via tail vein bleeding in mice, in which only 20-30 μL blood was withdrawn per time point. Due to the small blood volume, a dried-blood spot (DBS) technique was applied for sample processing. The utility of this technique was demonstrated using three test compounds (amodiaquine, chloroquine and chlorthalidone), with varying degrees of blood-to-plasma partition ratios. The PK studies were carried out in male Balb/c mouse weighing 25-30 g. The compounds were administered intravenously via the saphenous vein. Blood was collected by composite (retro-orbital plexus) or serial (tail vein bleeding) sampling techniques at different time points. Blood samples were processed as blood lysate or DBS. Blood or plasma samples were analyzed by sensitive and rapid UPLC-MS/MS methods. The blood concentrations (both from blood lysate and DBS) obtained from serial sampling matched with those from composite sampling. The ratio of blood AUC to plasma AUC correlated well with the in vitro blood-to-plasma partition ratio of the compounds. The systemic clearance and volume of distribution at steady state calculated from blood or plasma AUCs were in proportion to the respective AUCs. Our results indicated that the serial sampling technique would reduce the number of animals and also compound usage, as well as improve the quality of pharmacokinetic data. Also, the serial sampling technique does not require the use of anesthesia and allows estimation of inter-animal variability in PK. A small volume serial sampling is possible due to the availability of the DBS technique.

  5. Serine aspartate repeat protein D increases Staphylococcus aureus virulence and survival in blood

    NARCIS (Netherlands)

    Askarian, Fatemeh; Uchiyama, Satoshi; Valderrama, J. Andrés; Ajayi, Clement; Sollid, Johanna U E; van Sorge, Nina M.; Nizet, Victor; van Strijp, Jos A G; Johannessen, Mona

    2017-01-01

    Staphylococcus aureus expresses a panel of cell wall-anchored adhesins, including proteins belonging to the microbial surface components recognizing adhesive matrix molecule (MSCRAMM) family, exemplified by the serine-aspartate repeat protein D (SdrD), which serve key roles in colonization and

  6. Repeated action of a constant magnetic field on the blood coagulation system in artificially produced anemia

    Science.gov (United States)

    Zabrodina, L. V.

    1974-01-01

    Changes are discussed in the coagulatory system of the blood in rabbits under the influence of a constant magnetic field of an intensity of 2500 oersteds against the background of artificially induced anemia. Reversibility of the changes produced and the presence of the adaptational effect are noted. Taking all this into consideration, the changes involving the coagulatory system of the blood which arise under the influence of a constant magnetic field may be considered to have a nerve-reflex nature.

  7. Performance of an app measuring spot quality in dried blood spot sampling

    NARCIS (Netherlands)

    Veenhof, Herman

    2016-01-01

    Introduction: The Dried Blood Spot sampling (DBS) method gives patients and health care workers the opportunity for remote sampling using a drop of blood from a fingerprick on a sampling card which can be send to the laboratory by mail. Laboratory analysts frequently reject DBS samples because of

  8. Diagnosis of Carrion's disease by direct blood PCR in thin blood smear negative samples.

    Directory of Open Access Journals (Sweden)

    Juana del Valle Mendoza

    Full Text Available Bartonella bacilliformis is the etiologic agent of Carrion's disease. This disease has two well established phases, the most relevant being the so called Oroya Fever, in which B. bacilliformis infect the erythrocytes resulting in severe anemia and transient immunosuppression, with a high lethality in the absence of adequate antibiotic treatment. The presence of B. bacilliformis was studied in 113 blood samples suspected of Carrion's disease based on clinical criteria, despite the absence of a positive thin blood smear, by two different PCR techniques (using Bartonella-specific and universal 16S rRNA gene primers, and by bacterial culture. The specific 16S rRNA gene primers revealed the presence of 21 B. bacilliformis and 1 Bartonella elizabethae, while universal primers showed both the presence of 3 coinfections in which a concomitant pathogen was detected plus Bartonella, in addition to the presence of infections by other microorganisms such as Agrobacterium or Bacillus firmus. These data support the need to implement molecular tools to diagnose Carrion's disease.

  9. Diagnosis of Carrion’s Disease by Direct Blood PCR in Thin Blood Smear Negative Samples

    Science.gov (United States)

    Tinco Valdez, Carmen; Pons, Maria J.; del Valle, Luis J.; Oré, Verónica Casabona; Michelena, Denisse Champin; Mayra, Jorge Bazán; Gavidea, Víctor Zavaleta; Vargas, Martha; Ruiz, Joaquim

    2014-01-01

    Bartonella bacilliformis is the etiologic agent of Carrion's disease. This disease has two well established phases, the most relevant being the so called Oroya Fever, in which B. bacilliformis infect the erythrocytes resulting in severe anemia and transient immunosuppression, with a high lethality in the absence of adequate antibiotic treatment. The presence of B. bacilliformis was studied in 113 blood samples suspected of Carrion’s disease based on clinical criteria, despite the absence of a positive thin blood smear, by two different PCR techniques (using Bartonella-specific and universal 16S rRNA gene primers), and by bacterial culture. The specific 16S rRNA gene primers revealed the presence of 21 B. bacilliformis and 1 Bartonella elizabethae, while universal primers showed both the presence of 3 coinfections in which a concomitant pathogen was detected plus Bartonella, in addition to the presence of infections by other microorganisms such as Agrobacterium or Bacillus firmus. These data support the need to implement molecular tools to diagnose Carrion’s disease. PMID:24651298

  10. Distribution of dearomatised white spirit in brain, blood, and fat tissue after repeated exposure of rats

    DEFF Research Database (Denmark)

    Lof, A.; Lam, Henrik Rye; Gullstrand, E.

    1999-01-01

    spirit was 1.5 and 5.6 mg/kg in blood; 7.1 and 17.1 mg/kg in brain; 432 and 1452 mg/kg in fat tissue at the exposure levels of 400 and 800 p.p.m., respectively. The concentrations of n-nonane, n-decane, n-undecane, and total white spirit in blood and brain were not affected by the duration of exposure....... Two hours after the end of exposure the n-decane concentration decreased to about 25% in blood and 50% in brain. A similar pattern of elimination was also observed for n-nonane, n-undecane and total white spirit in blood and brain. In fat tissue the concentrations of n-nonane, n-decane, n......-undecane, and total white spirit increased during the 3 weeks of exposure. The time to reach steady-state concentrations is longer than 3 weeks. After the 3 weeks' exposure the fat tissue concentration of n-nonane, n-decane, n-undecane, and total white spirit decreased very slowly compared with the rate of decrease...

  11. Comparisons of polybrominated diphenyl ethers levels in paired South Korean cord blood, maternal blood, and breast milk samples.

    Science.gov (United States)

    Kim, Tae Hyung; Bang, Du Yeon; Lim, Hyun Jung; Won, A Jin; Ahn, Mee Young; Patra, Nabanita; Chung, Ki Kyung; Kwack, Seung Jun; Park, Kui Lea; Han, Soon Young; Choi, Wahn Soo; Han, Jung Yeol; Lee, Byung Mu; Oh, Jeong-Eun; Yoon, Jeong-Hyun; Lee, Jaewon; Kim, Hyung Sik

    2012-03-01

    Polybrominated diphenyl ethers (PBDEs), commonly used flame retardants, have been reported as potential endocrine disruptor and neurodevelopmental toxicants, thus giving rise to the public health concern. The goal of this study was to investigate the relationship between umbilical cord blood, maternal blood, and breast milk concentrations of PBDEs in South Korean. We assessed PBDE levels in paired samples of umbilical cord blood, maternal blood, and breast milk. The levels of seven PBDE congeners were measured in 21 paired samples collected from the Cheil Woman's Hospital (Seoul, Korea) in 2008. We also measured thyroid hormones levels in maternal and cord blood to assess the association between PBDEs exposure and thyroid hormone levels. However, there was no correlation between serum thyroxin (T4) and total PBDEs concentrations. The total PBDEs concentrations in the umbilical cord blood, maternal blood, and breast milk were 10.7±5.1 ng g(-1) lipid, 7.7±4.2 ng g(-1) lipid, and 3.0±1.8 ng g(-1) lipid, respectively. The ranges of total PBDE concentrations observed were 2.28-30.94 ng g(-1) lipid in umbilical cord blood, 1.8-17.66 ng g(-1) lipid in maternal blood, and 1.08-8.66 ng g(-1) lipid in breast milk. BDE-47 (45-73% of total PBDEs) was observed to be present dominantly in all samples, followed by BDE-153. A strong correlation was found for major BDE-congeners between breast milk and cord blood or maternal blood and cord blood samples. The measurement of PBDEs concentrations in maternal blood or breast milk may help to determine the concentration of PBDEs in infant.

  12. Repeatability of feed efficiency, carcass ultrasound, feeding behavior, and blood metabolic variables in finishing heifers divergently selected for residual feed intake.

    Science.gov (United States)

    Kelly, A K; McGee, M; Crews, D H; Sweeney, T; Boland, T M; Kenny, D A

    2010-10-01

    This study examined the relationship between feed efficiency and performance, and feeding behavior, blood metabolic variables, and various ultrasonic measurements in finishing beef heifers. Within-animal repeatability estimates of feed intake and behavior, performance, feed efficiency, ultrasonic body measures, and plasma analytes across the growing and finishing stages of the lifespan of the animal were also calculated. Fifty heifers previously ranked as yearlings on phenotypic residual feed intake (RFI) were used. Animals [initial BW = 418 (SD = 31.5) kg] were offered a TMR diet consisting of 70:30 concentrate and corn silage on a DM basis (ME 10.7 MJ/kg of DM; DM 530 g/kg) for 84 d. Feeding duration (min/d) and feeding frequency (events/d) were calculated for each animal on a daily basis using a computerized feeding system. Ultrasonic kidney fat and lumbar and rump fat and muscle depths were recorded on 3 equally spaced occasions during the experimental period. Blood samples were collected by jugular venipuncture on 4 occasions during the experimental period and analyzed for plasma concentrations of IGF-I, insulin, and various metabolites. Phenotypic RFI was calculated for all animals as the residuals from a regression model regressing DMI on ADG and midtest BW(0.75). Repeatability was calculated for several traits both within and between production phase using intraclass correlation and Pearson correlation coefficients as appropriate. Overall ADG, DMI, G:F, and RFI were 1.17 kg/d (SD = 0.19), 10.81 kg/d (SD = 1.02), 0.11 kg of BW gain/kg of DM (SD = 0.02), and 0.00 kg of DM/d (SD 0.59). Daily feeding events and eating rate tended to be positively correlated (P = 0.08) with RFI. Ultrasonic kidney fat depth tended to be related to G:F (r = -0.28; P = 0.07), and kidney fat accretion tended to be related to RFI (r = 0.29; P = 0.08). Plasma urea (r = 0.38; P glucose (r = -0.25; P = 0.07), glucose:insulin (r = 0.33; P 0.10) to any measure of feed efficiency

  13. Alleles of A Reelin CGG Repeat Do Not Convey Liability to Autism in A Sample from the CPEA Network

    OpenAIRE

    Devlin, B; Bennett, P.; Dawson, G.; Figlewicz, DA; Grigorenko, EL; McMahon, W.; Minshew, N; Pauls, D; Smith, M; Spence, MA; Rodier, PM; Stodgell, C; H. Coon; Lainart, J; Kim, SJ

    2004-01-01

    A recent study by Persico et al. [2001: Mol Psychiatry 6:150-159] suggests alleles of a CGG polymorphism, just 5′ of the reelin gene (RELN) initiator codon, confer liability for autism, especially alleles bearing 11 or more CGG repeats (long alleles). The association is consistent across both a case-control and family-based sample. We attempted to replicate their finding using a larger, independent family-based sample from the NIH Collaborative Programs of Excellence in Autism (CPEA) Network....

  14. Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children

    Science.gov (United States)

    Martial, Lisa C.; Aarnoutse, Rob E.; Schreuder, Michiel F.; Henriet, Stefanie S.; Brüggemann, Roger J. M.; Joore, Manuela A.

    2016-01-01

    Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling. PMID:27941974

  15. Repeated isolation of Salmonella enterica Goverdhan, a very rare serovar, from Danish poultry surveillance samples

    DEFF Research Database (Denmark)

    Pedersen, Karl; Sørensen, Gitte; Szabo, Istvan

    2014-01-01

    deviated in a single band. It is the first time this serovar has been described in samples from poultry. The origin of the bacterium is still unknown, but it is suggested that it may have been a pseudo-outbreak caused by contaminated sampling material. (C) 2014 Elsevier B.V. All rights reserved....

  16. [Tissue variability of androgen receptor gene in bulbospinal muscular atrophy--comparison of the number of CAG repeats between muscles and peripheral blood leukocytes].

    Science.gov (United States)

    Nakajima, H; Kimura, F; Shinoda, K; Ohsawa, N; Nakagawa, T; Shimizu, A

    1993-10-01

    We investigated an expansion of CAG repeats in exon 1 of androgen receptor gene in skeletal muscle tissue obtained from the patients with various neuro-muscular disorders (5 BSMA, 33 patients with amyotrophic lateral sclerosis, 3 patients with spinal progressive muscular atrophy and 2 patients with hereditary motor sensory neuropathy), by polymerase chain reaction (PCR) amplification according to LaSpadas' description. These muscle tissues had been stored at -70 degrees C freezer during 7 years. We also studied the tissue variation of CAG repeats size between muscles and peripheral blood leukocytes in 4 patients with BSMA. And we confirmed the increased number of CAG repeats in all 5 BSMA except for other patients with neurogenic muscular atrophy. In the 4 BSMA patients, we subcloned the PCR products from muscles tissues and peripheral blood leukocytes, and we determined the number of CAG repeats by sequencing. The repeats of them were 43-51, and all BSMA patients showed the same number of CAG repeats in muscles tissues and peripheral blood leukocytes. The CAG repeats fragment of BSMA may be stable region in frozen storage state for 7 years, and we didn't recognized the somatic variation at least between muscles tissues and peripheral blood leukocytes.

  17. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient.

  18. A simple Duplex-PCR to evaluate the DNA quality of anthropological and forensic samples prior short tandem repeat typing.

    Science.gov (United States)

    von Wurmb-Schwark, Nicole; Schwark, Thorsten; Harbeck, Michaela; Oehmichen, Manfred

    2004-04-01

    Typing of DNA from ancient or otherwise highly degraded material, e.g. formalin fixed tissues, can be difficult, time consuming and costly. Very often, genetic typing is not possible at all. We present an inexpensive and easy to use Duplex-PCR that amplifies a 164 bp fragment specific for nuclear DNA together with a 260 bp mitochondrial DNA fragment and that can be employed as a pretest prior to short tandem repeat (STR) typing. All together, we analyzed DNA from 20 ancient bones, 20 formalin fixed tissues and 20 other forensic samples in different concentrations. Each sample that failed in the presented Duplex-amplification was also negative for STR typing, while samples that showed strong and clear signals in the Duplex-PCR led to reproducible genetic profiles using the multiplex kits AmpFLSTR Identifiler and Powerplex ES. The Duplex-PCR worked as a reliable indicator of DNA quality in the sample.

  19. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-08-10

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pblood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (pblood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (psample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017. Published by Elsevier B.V.

  20. Word-Synchronous Optical Sampling of Periodically Repeated OTDM Data Words for True Waveform Visualization

    Science.gov (United States)

    Benkler, Erik; Telle, Harald R.

    2007-06-01

    An improved phase-locked loop (PLL) for versatile synchronization of a sampling pulse train to an optical data stream is presented. It enables optical sampling of the true waveform of repetitive high bit-rate optical time division multiplexed (OTDM) data words such as pseudorandom bit sequences. Visualization of the true waveform can reveal details, which cause systematic bit errors. Such errors cannot be inferred from eye diagrams and require word-synchronous sampling. The programmable direct-digital-synthesis circuit used in our novel PLL approach allows flexible adaption of virtually any problem-specific synchronization scenario, including those required for waveform sampling, for jitter measurements by slope detection, and for classical eye-diagrams. Phase comparison of the PLL is performed at 10-GHz OTDM base clock rate, leading to a residual synchronization jitter of less than 70 fs.

  1. Risk factors for complications in donors at first and repeat whole blood donation: a cohort study with assessment of the impact on donor return.

    Science.gov (United States)

    Wiersum-Osselton, Johanna C; Marijt-van der Kreek, Tanneke; Brand, Anneke; Veldhuizen, Ingrid; van der Bom, Johanna G; de Kort, Wim

    2014-01-01

    First-time donation is among recognised risk factors for vasovagal reactions to blood donation and reactions are known to reduce donor return. We assessed associations between potential risk factors and vasovagal reactions and needle-related complications in first-time whole blood donation in comparison to repeat donation and analysed the impact of complications on donor return. We performed a cohort study on whole blood donations in The Netherlands from 1/1/2010 to 31/12/2010 using data extracted from the blood service information system. Donation data up to 31/12/2011 were used to ascertain donor return. In 2010 28,786 donors made first whole blood donations and there were 522,958 repeat donations. Vasovagal reactions occurred in 3.9% of first donations by males and 3.5% of first donations by females compared to in 0.2% and 0.6%, respectively, of repeat donations. Associations of vasovagal reactions with other factors including age, body weight, systolic and diastolic blood pressure were similar in first-time and repeat donors. Needle-related complications occurred in 0.2% of male and 0.5% of female first-time donations and in 0.1% and 0.3%, respectively, of repeat donations. Among first-time donors, the return rate within 1 year was 82% following an uncomplicated first donation, but 55% and 61% following vasovagal reactions and needle-related complications, respectively; the corresponding percentages among repeat donors were 86%, 58% and 82%. Among first-time donors, females suffered less than males from vasovagal reactions. Other risk factors had similar associations among first-time and repeat donors. Vasovagal reactions and needle-related complications in both first-time and repeat donors are followed by reduced donor return.

  2. Forensic Identification of Human Blood: comparison of two one-step presumptive tests for blood screening of crime scene samples.

    Directory of Open Access Journals (Sweden)

    Ana Flávia Belchior Andrade

    2014-08-01

    Full Text Available Blood is the most common body fluid found at crime scenes. One-step presumptive tests have been designed as a rapid immunological test for the qualitative detection of human hemoglobin in stool samples (faecal occult blood their usefulness for forensic purposes has been demonstrated before. In this study we compare Hexagon OBTI kit and FOB One-step Bioeasy kit sensitivity in the analysis of diluted blood samples. With Hexagon OBTI, positive test results are achieved in whole blood dilutions up to 1:1.000. Sensitivity decreased with aged samples, if samples were not stored under low temperatures regardless of which presumptive test is used. Whole blood tests must take into consideration that “hook” effect may interfere. Comparing both tests, OBTI Hexagon Kit is more sensible to detect diluted blood, showing a wider detection window in all conditions. This is interesting when analyzing forensic samples as forensic analysts usually do not know about the history of the analyzed sample before its collection.

  3. A cautionary note on substituting spatial subunits for repeated temporal sampling in studies of site occupancy

    Science.gov (United States)

    Kendall, William L.; White, Gary C.

    2009-01-01

    1. Assessing the probability that a given site is occupied by a species of interest is important to resource managers, as well as metapopulation or landscape ecologists. Managers require accurate estimates of the state of the system, in order to make informed decisions. Models that yield estimates of occupancy, while accounting for imperfect detection, have proven useful by removing a potentially important source of bias. To account for detection probability, multiple independent searches per site for the species are required, under the assumption that the species is available for detection during each search of an occupied site. 2. We demonstrate that when multiple samples per site are defined by searching different locations within a site, absence of the species from a subset of these spatial subunits induces estimation bias when locations are exhaustively assessed or sampled without replacement. 3. We further demonstrate that this bias can be removed by choosing sampling locations with replacement, or if the species is highly mobile over a short period of time. 4. Resampling an existing data set does not mitigate bias due to exhaustive assessment of locations or sampling without replacement. 5. Synthesis and applications. Selecting sampling locations for presence/absence surveys with replacement is practical in most cases. Such an adjustment to field methods will prevent one source of bias, and therefore produce more robust statistical inferences about species occupancy. This will in turn permit managers to make resource decisions based on better knowledge of the state of the system.

  4. The impact of different blood sampling methods on laboratory rats under different types of anaesthesia

    DEFF Research Database (Denmark)

    Toft, Martin Fitzner; Petersen, Mikke Haxø; Dragsted, Nils

    2006-01-01

    for rats sampled from the tail vein, which showed fluctuations in body temperature in excess of 30 h after sampling. Increases in heart rate and blood pressure within the first hours after sampling indicated that periorbital puncture was the method that had the largest acute impact on the rats......Rats with implanted telemetry transponders were blood sampled by jugular puncture, periorbital puncture or tail vein puncture, or sampled by jugular puncture in carbon dioxide (CO?), isoflurane or without anaesthesia in a crossover design. Heart rate, blood pressure and body temperature were...... registered for three days after sampling. Initially blood pressure increased, but shortly after sampling it decreased, which led to increased heart rate. Sampling induced rapid fluctuations in body temperature, and an increase in body temperature. Generally, rats recovered from sampling within 2-3 h, except...

  5. A rapid and simple cannulation technique for repeated sampling of cerebrospinal fluid in freely moving rats

    NARCIS (Netherlands)

    Bouman, H.J.; Wimersma Greidanus, T.B. van

    1979-01-01

    A cannulation technique for frequent sampling of cerebrospinal fluid (CSF) in unanaesthetized freely moving rats is described. A permanent stainless steel cannula, constructed in such a way that no loss of CSF occurs, is placed into the rat's cisterna magna and fixed to the skull by anchoring screws

  6. Disposition of Lead (Pb) in Saliva and Blood of Sprague-Dawley Rats Following a Single or Repeated Oral Exposure to Pb-Acetate

    Energy Technology Data Exchange (ETDEWEB)

    Timchalk, Chuck; Lin, Yuehe; Weitz, Karl K.; Wu, Hong; Gies, Richard A.; Moore, Dean A.; Yantasee, Wassana

    2006-05-01

    Biological monitoring for lead (Pb) is usually based upon a determination of blood Pb concentration; however, saliva has been suggested as a non-invasive biological matrix for assessing exposure. To further evaluate the potential utility of saliva for biomonitoring, the disposition of Pb was evaluated in whole blood (WB), red blood cells (RBC), plasma, parotid gland, bone, and saliva following either a single oral dose of 100 mg Pb-acetate/kg body weight in rats or {approx}1-week after 5 sequential daily oral gavage doses of 1, 10, or 100 mg Pb-acetate/kg/day. Saliva volume, pH, total saliva protein, and ?-amylase activity were also determined. At specified times post-dosing groups of animals were anethetized and administered pilocarpine to induce salivation. Saliva was collected, the animals were humanely sacrificed, and tissue samples were likewise collected, weighed, and processed for Pb analysis. Following a single dose exposure to PB-acetate, Pb was detectable in all samples by 30 min post-dosing. For both the single and repeated dose treatments the concentration of Pb was highest in WB and RBC relative to plasma and saliva. However, the Pb rapidly redistributed (within 5-days post-treatment) from the blood into the bone compartment based on the substantial decrease in WB and RBC Pb concentration, and the concurrent increase in bone Pb following repeated exposure at all dose levels. Although there is clear variability in the observed Pb concentrations in plasma and saliva, there was a reasonable correlation (r2=0.922) between the average Pb concentrations in these biological matrices which was consistent with previous observations. The single oral dose of Pb-acetate resulted in a decrease in salivary pH which recovered by 24 hr post-dosing and a decrease in ?-amylase enzyme activity which did recover within 5-days of ceasing exposure. It is currently unclear what impact these slight functional changes may or may not have on Pb salivary clearance rates. These

  7. 间歇采样转发干扰参数分析%Jamming Parameter Analysis for Intermittent Sampling Repeater

    Institute of Scientific and Technical Information of China (English)

    邬诚; 陈新年

    2014-01-01

    间歇采样转发干扰的参数设置对干扰效果有较大影响,干扰参数决定了间歇采样转发干扰信号进入雷达接收机后的脉压结果。通过数学理论推导给出了间歇采样周期和干扰信号占空比两类干扰参数与干扰效果的明确数学对应关系,并通过数字仿真验证了数学推导和理论分析的正确性。%Jamming parameter settings of intermittent sampling repeater for jamming effects have a greater impact. Jamming parameters determine the pulse compression results for intermittent sampling repeater jamming signals into the radar receiver. An explicit mathematics correspon-dence is given of intermittent sampling period and duty cycle for jamming effects through mathe-matical derivation and analysis. Finally, the correctness of mathematical derivation and analysis is validated with digital simulation.

  8. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    National Research Council Canada - National Science Library

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-01-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried...

  9. 4D x-ray phase contrast tomography for repeatable motion of biological samples

    Science.gov (United States)

    Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto

    2016-09-01

    X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.

  10. Chemometric techniques on the analysis of Raman spectra of serum blood samples of breast cancer patients

    Science.gov (United States)

    Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.

    2008-02-01

    Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.

  11. Novel blood sampling method of an artificial endocrine pancreas via the cardiopulmonary bypass circuit.

    Science.gov (United States)

    Kawahito, Shinji; Higuchi, Seiichi; Mita, Naoji; Kitagawa, Tetsuya; Kitahata, Hiroshi

    2013-12-01

    We tried to perform continuous blood glucose monitoring during cardiovascular surgery involving cardiopulmonary bypass using an artificial endocrine pancreas (STG-22 or -55; Nikkiso, Tokyo, Japan); however, we often encountered problems during these procedures because insufficient blood was obtained for monitoring. Thus, we started performing the blood sampling via the venous side of the cardiopulmonary bypass circuit. As a result, continuous blood glucose monitoring using an artificial endocrine pancreas was proven to be stable and reliable during cardiovascular surgery involving cardiopulmonary bypass.

  12. Sampling errors in pH and blood gas analysis--an evaluation of three new arterial blood samplers.

    Science.gov (United States)

    Hutchison, A S; Dryburgh, F J; Ralston, S H

    1986-05-01

    We have tested the accuracy, acceptability and general performance of three recently-marketed samplers for arterial blood gas measurement (the Corning Arterial Blood Sampler, the Concord 'Pulsator' and the Sarstedt 'Monovette'). All three greatly reduce or eliminate the error of venous sampling, and the Corning and Sarstedt samplers eliminate the risk of dilution of the sample by excess heparin solution. A positive bias in pO2 measurement, more marked at higher levels, was demonstrated with the Concord and Sarstedt samplers, and the latter carry a slightly increased risk of cross-infection. None of the samplers completely overcame potential sampling errors.

  13. Repeatability of Blood Gas Parameters, Pco2 Gap, and Pco2 Gap to Arterial-to-Venous Oxygen Content Difference in Critically Ill Adult Patients

    Science.gov (United States)

    Mallat, Jihad; Lazkani, Ali; Lemyze, Malcolm; Pepy, Florent; Meddour, Mehdi; Gasan, Gaëlle; Temime, Johanna; Vangrunderbeeck, Nicolas; Tronchon, Laurent; Thevenin, Didier

    2015-01-01

    Abstract The objective of this study was to examine the repeatability of blood gas (BG) parameters and their derived variables such as the central venous-to-arterial carbon dioxide tension difference (▵Pco2) and the ratio of ▵Pco2 over the central arteriovenous oxygen content difference (▵Pco2/C(a-cv)O2) and to determine the smallest detectable changes in individual patients. A total of 192 patients with arterial and central venous catheters were included prospectively. Two subsequent arterial and central venous blood samples were collected immediately one after the other and analyzed using the same point-of-care BG analyzer. The samples were analyzed for arterial and venous BG parameters, ▵Pco2, and ▵Pco2/C(a-cv)O2 ratio. Repeatability was expressed as the smallest detectable difference (SDD) and the least significant change (LSC). A change in value of these parameters exceeding the SDD or the LSC should be regarded as real. The SDDs for arterial carbon dioxide tension, arterial oxygen saturation, central venous oxygen saturation (ScvO2), and ▵Pco2 were small: ±2.06 mm Hg, ±1.23%, 2.92%, and ±1.98 mm Hg, respectively, whereas the SDDs for arterial oxygen tension (Pao2) and ▵Pco2/C(a-cv)O2 were high: ±9.09 mm Hg and ±0.57 mm Hg/mL, respectively. The LSCs (%) for these variables were 5.06, 1.27, 4.44, 32.4, 9.51, and 38.5, respectively. The repeatability of all these variables was good except for Pao2 and ▵Pco2/C(a-cv)O2 ratio for which we observed an important inherent variability. Expressed as SDD, a ScvO2 change value of at least ±3% should be considered as true. The clinician must be aware that an apparent change in these variables in an individual patient might represent only an inherent variation. PMID:25621691

  14. Getting used to academic public speaking: global self-esteem predicts habituation in blood pressure response to repeated thesis presentations.

    Science.gov (United States)

    Elfering, Achim; Grebner, Simone

    2012-06-01

    Global self-esteem was tested to predict quicker cardiovascular adaptation during stressful oral thesis presentation and faster habituation from the first to the second and third thesis presentations. Nineteen graduate students initially rated their global self-esteem and afterwards orally presented their theses proposals in 20-min presentations to their thesis supervisor and peers. A second and third presentation of the revised thesis concepts took place at 4-weeks intervals. Ambulatory blood pressure and heart rate were assessed repeatedly during the presentations. Post-talk self ratings of stressfulness indicated presentations to be a strong public speaking stressor. One hundred and thirty-eight measurements of systolic (SBP), diastolic blood pressure (DBP), and heart rate (HR) showed a significant adaptation (decrease) during presentations. There was an overall mean level decrease from the first to the second, and the second to the third presentations in HR, but not in SBP and DBP. However, habituation in SBP and DBP across three presentations was significantly faster (p < .05) in those participants who initially reported higher levels of global self-esteem. Higher global self-esteem did not foster adaptation within the presentations. Self-esteem is discussed as an important individual resource that allows successful coping with recurring evaluative threats.

  15. Hematological Assessment in Pet Guinea Pigs (Cavia porcellus): Blood Sample Collection and Blood Cell Identification.

    Science.gov (United States)

    Zimmerman, Kurt; Moore, David M; Smith, Stephen A

    2015-09-01

    Pet guinea pigs are presented to veterinary clinics for routine care and treatment of clinical diseases. In addition to obtaining clinical history and exam findings, diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, the volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal guinea pigs are provided for comparison with in-house or commercial test results. A description of the morphology of guinea pig leukocytes is provided to assist in performing a differential count.

  16. Alleles of a reelin CGG repeat do not convey liability to autism in a sample from the CPEA network.

    Science.gov (United States)

    Devlin, Bernie; Bennett, Pamela; Dawson, Geraldine; Figlewicz, Denise A; Grigorenko, Elena L; McMahon, William; Minshew, Nancy; Pauls, David; Smith, Moyra; Spence, M Anne; Rodier, Patricia M; Stodgell, Chris; Schellenberg, Gerard D

    2004-04-01

    A recent study by Persico et al. [2001: Mol Psychiatry 6:150-159] suggests alleles of a CGG polymorphism, just 5' of the reelin gene (RELN) initiator codon, confer liability for autism, especially alleles bearing 11 or more CGG repeats (long alleles). The association is consistent across both a case-control and family-based sample. We attempted to replicate their finding using a larger, independent family-based sample from the NIH Collaborative Programs of Excellence in Autism (CPEA) Network. In our data, allele transmissions to individuals with autism versus unaffected individuals are unbiased, both when alleles are classified by repeat length and when they are classified into long/short categories. Because of the apparent linkage of autism to chromosome 7q, particularly related to the development of language, we also evaluate the relationship between Reelin alleles and the age at which autism subjects use their first word or first phrase. Neither is significantly associated with Reelin alleles. Our results are not consistent with a major role for Reelin alleles in liability to autism. Published 2004 Wiley-Liss, Inc.

  17. Hematologic assessment in pet rats, mice, hamsters, and gerbils: blood sample collection and blood cell identification.

    Science.gov (United States)

    Lindstrom, Nicole M; Moore, David M; Zimmerman, Kurt; Smith, Stephen A

    2015-01-01

    Hamsters, gerbils, rats, and mice are presented to veterinary clinics and hospitals for prophylactic care and treatment of clinical signs of disease. Physical examination, history, and husbandry practice information can be supplemented greatly by assessment of hematologic parameters. As a resource for veterinarians and their technicians, this article describes the methods for collection of blood, identification of blood cells, and interpretation of the hemogram in mice, rats, gerbils, and hamsters.

  18. Brief Report: The Temporal Stability of the Repeatable Battery for the Assessment of Neuropsychological Status Effort Index in Geriatric Samples

    Science.gov (United States)

    O'Mahar, Kerry M.; Duff, Kevin; Scott, James G.; Linck, John F.; Adams, Russell L.; Mold, James W.

    2012-01-01

    The Effort Index (EI) of the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) was developed to identify inadequate effort. Although researchers have examined its validity, the reliability of the EI has not been evaluated. The current study examined the temporal stability of the EI across 1 year in two independent samples of older adults. One sample consisted of 445 cognitively intact older adults (mean age = 72.89; 59% having 12–15 years of education) and the second sample consisted of 51 individuals diagnosed with amnestic Mild Cognitive Impairment (mean age = 82.41; 41% having 12–15 years of education). For both samples, the EI was found to have low stability (Spearman's ρ = .32–.36). When participants were divided into those whose EI stayed stable or improved versus those whose EI worsened (i.e., declining effort) on retesting, it was observed that individuals with lower baseline RBANS Total scores tended to worsen on the EI across time. Overall, the findings suggest low temporal stability of the EI in two geriatric samples. In particular, individuals with poorer cognition at baseline could present with poorer effort across time. These findings also suggest the need to further examine the temporal stability of other effort measures. PMID:22075575

  19. Adaptive geostatistical sampling enables efficient identification of malaria hotspots in repeated cross-sectional surveys in rural Malawi

    Science.gov (United States)

    Chipeta, Michael G.; McCann, Robert S.; Phiri, Kamija S.; van Vugt, Michèle; Takken, Willem; Diggle, Peter; Terlouw, Anja D.

    2017-01-01

    Introduction In the context of malaria elimination, interventions will need to target high burden areas to further reduce transmission. Current tools to monitor and report disease burden lack the capacity to continuously detect fine-scale spatial and temporal variations of disease distribution exhibited by malaria. These tools use random sampling techniques that are inefficient for capturing underlying heterogeneity while health facility data in resource-limited settings are inaccurate. Continuous community surveys of malaria burden provide real-time results of local spatio-temporal variation. Adaptive geostatistical design (AGD) improves prediction of outcome of interest compared to current random sampling techniques. We present findings of continuous malaria prevalence surveys using an adaptive sampling design. Methods We conducted repeated cross sectional surveys guided by an adaptive sampling design to monitor the prevalence of malaria parasitaemia and anaemia in children below five years old in the communities living around Majete Wildlife Reserve in Chikwawa district, Southern Malawi. AGD sampling uses previously collected data to sample new locations of high prediction variance or, where prediction exceeds a set threshold. We fitted a geostatistical model to predict malaria prevalence in the area. Findings We conducted five rounds of sampling, and tested 876 children aged 6–59 months from 1377 households over a 12-month period. Malaria prevalence prediction maps showed spatial heterogeneity and presence of hotspots—where predicted malaria prevalence was above 30%; predictors of malaria included age, socio-economic status and ownership of insecticide-treated mosquito nets. Conclusions Continuous malaria prevalence surveys using adaptive sampling increased malaria prevalence prediction accuracy. Results from the surveys were readily available after data collection. The tool can assist local managers to target malaria control interventions in areas with the

  20. Repeated measurements of blood lactate concentration as a prognostic marker in horses with acute colitis evaluated with classification and regression trees (CART) and random forest analysis.

    Science.gov (United States)

    Petersen, M B; Tolver, A; Husted, L; Tølbøll, T H; Pihl, T H

    2016-07-01

    The objective of this study was to investigate the prognostic value of single and repeated measurements of blood l-lactate (Lac) and ionised calcium (iCa) concentrations, packed cell volume (PCV) and plasma total protein (TP) concentration in horses with acute colitis. A total of 66 adult horses admitted with acute colitis (2 mmol/L (sensitivity, 0.72; specificity, 0.8). In conclusion, blood lactate concentration measured at admission and repeated 6 h later aided the prognostic evaluation of horses with acute colitis in this population with a very high mortality rate. This should allow clinicians to give a more reliable prognosis for the horse.

  1. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E. (Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia))

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  2. Autocorrelation and cross-correlation between hCGβ and PAPP-A in repeated sampling during first trimester of pregnancy

    DEFF Research Database (Denmark)

    Nørgaard, Pernille; Wright, Dave; Ball, Susan;

    2013-01-01

    Theoretically, repeated sampling of free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein-A (PAPP-A) in the first trimester of pregnancy might improve performance of risk assessment of trisomy 21 (T21). To assess the performance of a screening test involving repeated...

  3. Association between suicidal symptoms and repeat suicidal behaviour within a sample of hospital-treated suicide attempters

    Science.gov (United States)

    van Borkulo, Claudia D.; O’Connor, Rory C.

    2017-01-01

    Background Suicidal behaviour is the end result of the complex relation between many factors which are biological, psychological and environmental in nature. Network analysis is a novel method that may help us better understand the complex association between different factors. Aims To examine the relationship between suicidal symptoms as assessed by the Beck Scale for Suicide Ideation and future suicidal behaviour in patients admitted to hospital following a suicide attempt, using network analysis. Method Secondary analysis was conducted on previously collected data from a sample of 366 patients who were admitted to a Scottish hospital following a suicide attempt. Network models were estimated to visualise and test the association between baseline symptom network structure and suicidal behaviour at 15-month follow-up. Results Network analysis showed that the desire for an active attempt was found to be the most central, strongly related suicide symptom. Of the 19 suicide symptoms that were assessed at baseline, 10 symptoms were directly related to repeat suicidal behaviour. When comparing baseline network structure of repeaters (n=94) with the network of non-repeaters (n=272), no significant differences were found. Conclusions Network analysis can help us better understand suicidal behaviour by visualising the complex relation between relevant symptoms and by indicating which symptoms are most central within the network. These insights have theoretical implications as well as informing the assessment and treatment of suicidal behaviour. Declaration of interest None. Copyright and usage © The Royal College of Psychiatrists 2017. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) license. PMID:28507771

  4. Lipid emulsion solution: A novel cause of hemolysis in serum and plasma blood samples.

    Science.gov (United States)

    Jaben, Elizabeth A; Koch, Christopher D; Karon, Brad S

    2011-02-01

    After several hemolyzed blood samples were received in the laboratory, we investigated lipid emulsion/TPN as a novel cause of hemolysis. Whole blood was spiked with lipid emulsion and TPN. Hemolysis was proportional to the amount of lipid emulsion present in whole blood, with less hemolysis occurring in blood gas syringes compared to vacutainer tubes. Collection of specimens in blood gas syringes may prevent hemolysis in patients on lipid emulsion. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Trace samples of human blood in mosquitoes as a forensic investigation tool.

    Science.gov (United States)

    Rabêlo, K C N; Albuquerque, C M R; Tavares, V B; Santos, S M; Souza, C A; Oliveira, T C; Oliveira, N C L; Crovella, S

    2015-11-23

    Investigations of any type of crime invariably starts at the crime scene by collecting evidence. Thus, the purpose of this research was to collect and analyze an entomological trace from an environment that is similar to those of indoor crime scenes. Hematophagous mosquitoes were collected from two residential units; saliva of volunteers that were residents in the units was also collected for genetic analysis as reference samples. We examined the allele frequencies of 15 short tandem repeat loci (D8S1179, D21S11, D7S820, CSF1PO, D3S1358, TH01, D13S317, D16S539, D2S1338, D19S433, vWA, TPOX, D18S51, D5S818, and FGA) and amelogenin. A total of 26 female hematophagous mosquitoes were identified as Aedes aegypti, Aedes albopictus, and Culex quinquefasciatus; we were able to obtain 11 forensically valid genetic profiles, with a minimum of 0.028203 ng/μL of human DNA. Thus, the results of this study showed that it was possible to correlate human genetic information from mosquitoes with the volunteer reference samples, which validates the use of this information as forensic evidence. Furthermore, we observed mixed genetic profiles from one mosquito. Therefore, it is clearly important to collect these insects indoors where crimes were committed, because it may be possible to find intact genetic profiles of suspects in the blood found in the digestive tract of hematophagous mosquitoes for later comparison to identify an offender and/or exclude suspects.

  6. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    Science.gov (United States)

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  7. Minimally invasive blood sampling method for genetic studies on Gopherus tortoises

    Directory of Open Access Journals (Sweden)

    García–Feria, L. M.

    2015-04-01

    Full Text Available Obtaining good quality tissue samples is the first hurdle in any molecular study. This is especially true for studies involving management and conservation of wild fauna. In the case of tortoises, the most common sources of DNA are blood samples. However, only a minimal amount of blood is required for PCR assays. Samples are obtained mainly from the brachial and jugular vein after restraining the animal chemically, or from conscious individuals by severe handling methods and clamping. Herein, we present a minimally invasive technique that has proven effective for extracting small quantities of blood, suitable for genetic analyses. Furthermore, the samples obtained yielded better DNA amplification than other cell sources, such as cloacal epithelium cells. After two years of use on wild tortoises, this technique has shown to be harmless. We suggest that sampling a small amount of blood could also be useful for other types of analyses, such as physiologic and medical monitoring.

  8. Comparison of glucose determinations on blood samples collected in three types of tubes.

    Science.gov (United States)

    Li, Geling; Cabanero, Michael; Wang, Zhenglong; Wang, Huiying; Huang, Tao; Alexis, Herol; Eid, Ikram; Muth, Gilad; Pincus, Matthew R

    2013-01-01

    Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with serum separator, grey-top tubes with a fluoride glycolysis inhibitor, and heparin-containing green-top tubes which prevent clot formation. As part of a quality assurance project, we investigated whether glucose levels differed in the three tube types from each of 18 volunteers on a prolonged standing of 4 hours. We then determined the glucose concentrations of all three tubes from each of the 18 volunteers. We used refrigerated samples over a five-day period to determine if the initial values were reproducible. Surprisingly, after standing for four hours at room temperature, we found that the glucose levels in the three tubes from each volunteer were statistically indistinguishable from one another using the two-tailed paired t-test. Also, a linear regression analysis showed that the values of glucose for the three pairs of two tube types were closely correlated with one another, with correlation coefficients of >0.97, slopes close to 1, and Y-intercepts close to 0. These results suggest that blood collection in any of these tubes will render similar values for serum glucose even after standing for four hours. The tubes were then refrigerated at 4°C and re-analyzed after another six hours and then once per day for the next four days. Beginning at the first day at the six-hour determination, the glucose levels in the red- and grey-top tubes were statistically indistinguishable from one another but not in the red- and green-top tubes and in the grey- and green-top tubes. This was due to a steady decrease in the glucose levels in the green-top tubes. The glucose levels in the

  9. DNA methylome profiling using neonatal dried blood spot samples: a proof-of-principle study.

    Science.gov (United States)

    Hollegaard, Mads Vilhelm; Grauholm, Jonas; Nørgaard-Pedersen, Bent; Hougaard, David Michael

    2013-04-01

    DNA methylation is the most common DNA modification and perhaps the best described epigenetic modification. It is believed to be important for genomic imprinting and gene regulation and has been associated with the development of diseases such as schizophrenia and some types of cancer. Neonatal dried blood spot samples, commonly known as Guthrie cards, are routinely collected worldwide to screen newborns for diseases. Some countries, including Denmark, have been storing the excess neonatal dried blood spot samples in biobanks for decades. Representing a high percentage of the population under a certain age, the neonatal dried blood spot samples are a potential alternative to collecting new samples to study diseases. As such, neonatal dried blood spot samples have previously been used for DNA genotyping studies with excellent results. However, the amount of material available for research is often limited, challenging researchers to generate the most data from a limited quantity of material. In this proof-of-principle study, we address whether two 3.2mm disks punched from a neonatal dried blood spot sample contain enough DNA for genome-wide methylome profiling, measuring 27,578 loci at the same time. We selected two subjects and carried out the following with each: 1) collected an adult whole-blood sample as reference, 2) spotted a fraction of the whole-blood sample onto a similar type of filter paper as used in the newborn screening and stored it for 3years to serve as a dried blood spot reference, and 3) identified the archived neonatal dried blood spot samples, stored for 26-28years, in the Danish Newborn Screening Biobank as a representative of the archived samples. For comparison, we used two different kits for DNA extraction. The DNA, extracted using the Extract-N-Amp Blood PCR kit, was analyzed, and no statistically significant differences were observed (Pprofile of the reference whole-blood samples to the dried blood spot references. This indicates that two

  10. Diversity of nuclear short tandem repeat loci in representative sample of North-eastern Bosnian and Herzegovina population

    Directory of Open Access Journals (Sweden)

    Hadžiavdić Vesna

    2012-01-01

    Full Text Available Diversity of nuclear microsatellite markers were analyzed in a reference sample of the population of northeast Bosnia and Herzegovina. 437 samples taken from unrelated individuals were processed and three samples of paternity proof were shown. Detection effectiveness profile of the research, points to a valid choice of method of extraction, amplification and genotyping short tandem repeat (STR loci with PowerPlextm16 kit. Genetic analysis of allelic variants of the 15 STR loci PowerPlextm16 kit detected 17 samples determined as rare allelic variants or microvariants. Samples were divided into 15 different allelic variants at 7 different loci, and are: in locus D7S820, D16S539, D3S1358, D18S51, PENTA D, PENTA E and in locus vWA. Genetic analysis of mutations in cases of paternity determined three examples of single-step mutations in the loci FGA, Penta D and D3S1358. Genetic analysis of observed STR loci detected three allelic variant of genotype combination 7/10/11.3 in locus D7S820 Type II. Population genetic analysis of STR loci in a representative sample of the population of northeast Bosnia and Herzegovina included the application of the assessment tests of within-population genetic diversity and interpopulation diversity, as well as genetic differentiation between populations: North-eastern Bosnia and Herzegovina (BH and BH general reference, then the Croatian population, Macedonian, Serbian and Slovenian. Based on the result analysis of specific forensic parameters, it can be assumed that the most informative marker is PENTA E for population genetic analysis and forensic testing in the population of northeast Bosnia and Herzegovina. Research results fit regional STR database of this part of Europe.

  11. Microwave Blood Thawing: Biochemical Analysis of Small Samples of Thawed Red Blood Cells.

    Science.gov (United States)

    1984-01-01

    lactate + NAD+ ( Lehninger , 1977) The large increase in pyruvate observed at 6 hours post-wash was most likely due to the large lactate concentrations at...Storage of Blood. London: Academic Press. Lehninger , A.L. 1977. Biochemistry. New York: Worth Publishers, Inc. Lewis, G.P. 1965. Method using o-tolidine

  12. Characterization at the individual cell level and in whole blood samples of shear stress preventing red blood cells aggregation.

    Science.gov (United States)

    Lee, K; Kinnunen, M; Danilina, A V; Ustinov, V D; Shin, S; Meglinski, I; Priezzhev, A V

    2016-05-03

    The aggregation of red blood cells (RBC) is an intrinsic feature of blood that has a strong impact on its microcirculation. For a number of years it has been attracting a great attention in basic research and clinical studies. Here, we study a relationship between the RBC aggregation parameters measured at the individual cell level and in a whole blood sample. The home made optical tweezers were used to measure the aggregating and disaggregating forces for a pair of interacting RBCs, at the individual cell level, in order to evaluate the corresponding shear stresses. The RheoScan aggregometer was used for the measurements of critical shear stress (CSS) in whole blood samples. The correlation between CSS and the shear stress required to stop an RBC pair from aggregating was found. The shear stress required to disaggregate a pair of RBCs using the double channel optical tweezers appeared to be about 10 times higher than CSS. The correlation between shear stresses required to prevent RBCs from aggregation at the individual cell level and in whole blood samples was estimated and assessed quantitatively. The experimental approach developed has a high potential for advancing hemorheological studies.

  13. Monitoring of hematopoietic chimerism after transplantation for pediatric myelodysplastic syndrome: real-time or conventional short tandem repeat PCR in peripheral blood or bone marrow?

    Science.gov (United States)

    Willasch, Andre M; Kreyenberg, Hermann; Shayegi, Nona; Rettinger, Eva; Meyer, Vida; Zabel, Marion; Lang, Peter; Kremens, Bernhard; Meisel, Roland; Strahm, Brigitte; Rossig, Claudia; Gruhn, Bernd; Klingebiel, Thomas; Niemeyer, Charlotte M; Bader, Peter

    2014-12-01

    Quantitative real-time PCR (qPCR) has been proposed as a highly sensitive method for monitoring hematopoietic chimerism and may serve as a surrogate marker for the detection of minimal residual disease minimal residual disease in myelodysplastic syndrome (MDS), until specific methods of detection become available. Because a systematic comparison of the clinical utility of qPCR with the gold standard short tandem repeat (STR)-PCR has not been reported, we retrospectively measured chimerism by qPCR in 54 children transplanted for MDS in a previous study. Results obtained by STR-PCR in the initial study served as comparison. Because the detection limit of qPCR was sufficiently low to detect an autologous background, we defined the sample as mixed chimera if the proportion of recipient-derived cells exceeded .5%. The true positive rates were 100% versus 80% (qPCR versus STR-PCR, not significant), and mixed chimerism in most cases was detected earlier by qPCR than by STR-PCR (median, 31 days) when chimerism was quantified concurrently in peripheral blood and bone marrow. Both methods revealed a substantial rate of false positives (22.7% versus 13.6%, not significant), indicating the importance of serial testing of chimerism to monitor its progression. Finally, we propose criteria for monitoring chimerism in pediatric MDS with regard to the subtypes, specimens, PCR method, and timing of sampling.

  14. Intrauterine insemination of cultured peripheral blood mononuclear cells prior to embryo transfer improves clinical outcome for patients with repeated implantation failures.

    Science.gov (United States)

    Madkour, Aicha; Bouamoud, Nouzha; Louanjli, Noureddine; Kaarouch, Ismail; Copin, Henri; Benkhalifa, Moncef; Sefrioui, Omar

    2016-02-01

    Implantation failure is a major limiting factor in assisted reproduction improvement. Dysfunction of embryo-maternal immuno-tolerance pathways may be responsible for repeated implantation failures. This fact is supported by immunotropic theory stipulating that maternal immune cells, essentially uterine CD56+ natural killer cells, are determinants of implantation success. In order to test this hypothesis, we applied endometrium immuno-modulation prior to fresh embryo transfer for patients with repeated implantation failures. Peripheral blood mononuclear cells were isolated from repeated implantation failure patients undergoing assisted reproductive technology cycles. On the day of ovulation induction, cells were isolated and then cultured for 3 days and transferred into the endometrium cavity prior to fresh embryo transfer. This immunotherapy was performed on 27 patients with repeated implantation failures and compared with another 27 patients who served as controls. Implantation and clinical pregnancy were increased significantly in the peripheral blood mononuclear cell test versus control (21.54, 44.44 vs. 8.62, 14.81%). This finding suggests a clear role for endometrium immuno-modulation and the inflammation process in implantation success. Our study showed the feasibility of intrauterine administration of autologous peripheral blood mononuclear cells as an effective therapy to improve clinical outcomes for patients with repeated implantation failures and who are undergoing in vitro fertilization cycles.

  15. Additional notes on clinical repeated-dose pharmacokinetic trials applying a peak-and-trough sampling design to estimate oral clearance.

    Science.gov (United States)

    Takaai, Mari; Kayano, Yuichiro; Shimizu, Takako; Taguchi, Masato; Hashimoto, Yukiya

    2008-01-01

    In the previous study, we performed a simulation of a clinical pharmacokinetic trial, in which blood was sampled at two time points corresponding to the peak concentration (C(peak)) and trough concentration (C(trough)) following repetitive oral administration at the dose, D, and dosing interval, tau. The approximate oral clearance (CL/F(approx)), estimated as 2 x D/(C(peak) x tau+C(trough) x tau), is accurate for drugs with an elimination half-life comparative to or longer than tau; however, it was suggested that we might not use CL/F(approx) for drugs with a considerably short elimination half-life relative to tau. In the present study, we evaluated the accuracy of the alternative oral clearance (CL/F(exp)) estimated by the simple monoexponential model. In contrast to CL/F(approx), CL/F(exp) was accurate for drugs with a short elimination half-life relative to tau. The present finding in conjunction with our previous study suggested that the peak-and-trough sampling design is promising for the clinical repeated-dose pharmacokinetic trial for drugs with not only slow but also rapid elimination from the body. We think that the accuracy and precision of the two analysis methods to estimate oral clearance (CL/F(approx) and CL/F(exp)) for a target drug should be evaluated carefully before and after a real clinical trial.

  16. Evaluation of a new handheld point-of-care blood gas analyser using 100 equine blood samples.

    Science.gov (United States)

    Bardell, David; West, Eleanor; Mark Senior, J

    2017-02-22

    To determine whether the Enterprise point-of-care blood analysis system (EPOC) produces results in agreement with two other blood gas analysers in regular clinical use (i-STAT and Radiometer ABL77) and to investigate the precision of the new machine when used with equine whole blood. Prospective, randomized, non-blinded, comparative laboratory analyser study. Horses admitted to a university teaching hospital requiring arterial or venous blood gas analysis as part of their routine clinical management. One hundred equine blood samples were run immediately, consecutively and in randomized order on three blood gas analysers. Results of variables common to all three analysers were tested for agreement and compared with guidelines used in human medicine. These require 80% of results from the test analyser to fall within a defined range or percentage of results from the comparator devices to achieve acceptability. Additionally, 21 samples were run twice in quick succession on the EPOC analyser to investigate precision. Agreement targets were not met for haematocrit, haemoglobin and base excess for either i-STAT or ABL77 analysers. EPOC precision targets were not met for partial pressure of carbon dioxide, ionized calcium, haematocrit and haemoglobin. Overall comparative performance of the EPOC was good to excellent for pH, oxygen tension, potassium, bicarbonate and oxygen saturation of haemoglobin, but marginal to poor for other parameters. The EPOC may be useful in performing analysis of equine whole blood, but trend analysis of carbon dioxide tension, ionized calcium, haematocrit and haemoglobin should be interpreted with caution. The EPOC should not be used interchangeably with other blood gas analysers. Copyright © 2016 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  17. Benchmarking sample preparation/digestion protocols reveals tube-gel being a fast and repeatable method for quantitative proteomics.

    Science.gov (United States)

    Muller, Leslie; Fornecker, Luc; Van Dorsselaer, Alain; Cianférani, Sarah; Carapito, Christine

    2016-12-01

    Sample preparation, typically by in-solution or in-gel approaches, has a strong influence on the accuracy and robustness of quantitative proteomics workflows. The major benefit of in-gel procedures is their compatibility with detergents (such as SDS) for protein solubilization. However, SDS-PAGE is a time-consuming approach. Tube-gel (TG) preparation circumvents this drawback as it involves directly trapping the sample in a polyacrylamide gel matrix without electrophoresis. We report here the first global label-free quantitative comparison between TG, stacking gel (SG), and basic liquid digestion (LD). A series of UPS1 standard mixtures (at 0.5, 1, 2.5, 5, 10, and 25 fmol) were spiked in a complex yeast lysate background. TG preparation allowed more yeast proteins to be identified than did the SG and LD approaches, with mean numbers of 1979, 1788, and 1323 proteins identified, respectively. Furthermore, the TG method proved equivalent to SG and superior to LD in terms of the repeatability of the subsequent experiments, with mean CV for yeast protein label-free quantifications of 7, 9, and 10%. Finally, known variant UPS1 proteins were successfully detected in the TG-prepared sample within a complex background with high sensitivity. All the data from this study are accessible on ProteomeXchange (PXD003841).

  18. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.

    Science.gov (United States)

    Cakirca, Gokhan; Erdal, Huseyin

    2017-05-01

    Pneumatic tube systems (PTSs) are widely used in many hospitals because they lead to reduced turnaround times and cost efficiency. However, PTSs may affect the quality of the blood samples transported to the laboratory. The aim of this study was to investigate the effect of the PTS used in our hospital on the hemolysis of the biochemical blood samples transported to the laboratory. A total of 148 samples were manually transported to the laboratory by hospital staff, 148 samples were transported with the PTS, and 113 were transported with the PTS without use of sponge-rubber inserts (PTSws). Hemolysis rates and the levels of biochemical analytes for the different transportation methods were compared. No significant difference was found between the samples transported manually and with the PTS with regard to hemolysis rate and the levels of biochemical analytes. However, the samples transported with the PTSws showed a significant difference compared with the samples transported manually and with the PTS with regard to hemolysis rate and potassium and lactate dehydrogenase levels. The percentages of the samples that exceeded the permissible threshold for the hemolysis among the samples transported manually, with the PTS, and with the PTSws were 10%, 8%, and 47%, respectively. A PTS can be used safely for transporting biochemistry blood samples to the laboratory. However, a sponge-rubber insert that holds sample tubes must be used with the PTS to prevent the hemolysis of blood samples. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  19. Multi-Locus Variable-Number Tandem Repeat Profiling of Salmonella enterica Serovar Typhi Isolates from Blood Cultures and Gallbladder Specimens from Makassar, South-Sulawesi, Indonesia

    NARCIS (Netherlands)

    Hatta, M.; Pastoor, R.; Scheelbeek, P.F.D.; Sultan, A.R.; Dwiyanti, R.; Labeda, I.; Smits, H.L.

    2011-01-01

    Multi-locus variable-number tandem repeat analysis differentiated 297 Salmonella enterica serovar Typhi blood culture isolates from Makassar in 76 genotypes and a single unique S. Typhi genotype was isolated from the cholecystectomy specimens of four patients with cholelithiasis. The high diversity

  20. Multi-Locus Variable-Number Tandem Repeat Profiling of Salmonella enterica Serovar Typhi Isolates from Blood Cultures and Gallbladder Specimens from Makassar, South-Sulawesi, Indonesia

    NARCIS (Netherlands)

    Hatta, M.; Pastoor, R.; Scheelbeek, P.F.D.; Sultan, A.R.; Dwiyanti, R.; Labeda, I.; Smits, H.L.

    2011-01-01

    Multi-locus variable-number tandem repeat analysis differentiated 297 Salmonella enterica serovar Typhi blood culture isolates from Makassar in 76 genotypes and a single unique S. Typhi genotype was isolated from the cholecystectomy specimens of four patients with cholelithiasis. The high diversity

  1. Modulatory influence of rarely repeated of immobilization episodes on the interleukin-1β-dependent reaction of blood leukocytes and hepatoprotective effect of restraint stress.

    Science.gov (United States)

    Tseilikman, O B; Tseilikman, V E; Linin, A V; Gubkin, D A; Rudina, E A; Trubetskoy, S A; Ivanov, P V; Pozdnyakov, E A

    2011-02-01

    Repeated episodes of 1-h restraint stress were accompanied by a decrease in the sensitivity of blood leukocytes and cytochrome P450-dependent monooxygenases of the liver to recombinant IL-1β. These changes are associated with the anti-inflammatory hepatoprotective effect of chronic stress.

  2. Leukocyte count affects expression of reference genes in canine whole blood samples

    NARCIS (Netherlands)

    Piek, C.J.; Brinkhof, B.; Rothuizen, J.; Dekker, A.; Penning, L.C.

    2011-01-01

    Background The dog is frequently used as a model for hematologic human diseases. In this study the suitability of nine potential reference genes for quantitative RT-PCR studies in canine whole blood was investigated. Findings The expression of these genes was measured in whole blood samples of 263 i

  3. Continuous quality control of the blood sampling procedure using a structured observation scheme

    DEFF Research Database (Denmark)

    Seemann, Tine Lindberg; Nybo, Mads

    2016-01-01

    blood drawings by 39 phlebotomists were observed in the pilot study, while 84 blood drawings by 34 phlebotomists were observed in the follow-up study. In the pilot study, the three major error items were hand hygiene (42% error), mixing of samples (22%), and order of draw (21%). Minor significant...

  4. Dried blood spots on carboxymethyl cellulose sheets: Rapid sample preparation based on dissolution and precipitation

    DEFF Research Database (Denmark)

    Skoglund Ask, Kristine; Pedersen-Bjergaard, Stig; Gjelstad, Astrid

    2016-01-01

    This short communication describes the use of carboxymethyl cellulose sheets as sampling material for dried blood spots. Whole blood, spiked with quetiapine, a hydrophobic and basic small molecule drug substance, was spotted on the sheet and subsequently dried. The dried spot was then almost...

  5. Mining the Dynamic Genome: A Method for Identifying Multiple Disease Signatures Using Quantitative RNA Expression Analysis of a Single Blood Sample

    Directory of Open Access Journals (Sweden)

    Samuel Chao

    2015-12-01

    Full Text Available Background: Blood has advantages over tissue samples as a diagnostic tool, and blood mRNA transcriptomics is an exciting research field. To realize the full potential of blood transcriptomic investigations requires improved methods for gene expression measurement and data interpretation able to detect biological signatures within the “noisy” variability of whole blood. Methods: We demonstrate collection tube bias compensation during the process of identifying a liver cancer-specific gene signature. The candidate probe set list of liver cancer was filtered, based on previous repeatability performance obtained from technical replicates. We built a prediction model using differential pairs to reduce the impact of confounding factors. We compared prediction performance on an independent test set against prediction on an alternative model derived by Weka. The method was applied to an independent set of 157 blood samples collected in PAXgene tubes. Results: The model discriminated liver cancer equally well in both EDTA and PAXgene collected samples, whereas the Weka-derived model (using default settings was not able to compensate for collection tube bias. Cross-validation results show our procedure predicted membership of each sample within the disease groups and healthy controls. Conclusion: Our versatile method for blood transcriptomic investigation overcomes several limitations hampering research in blood-based gene tests.

  6. Standardised Resting Time Prior to Blood Sampling and Diurnal Variation Associated with Risk of Patient Misclassification

    DEFF Research Database (Denmark)

    Bøgh Andersen, Ida; Brasen, Claus L.; Christensen, Henry;

    2015-01-01

    BACKGROUND: According to current recommendations, blood samples should be taken in the morning after 15 minutes' resting time. Some components exhibit diurnal variation and in response to pressures to expand opening hours and reduce waiting time, the aims of this study were to investigate...... the impact of resting time prior to blood sampling and diurnal variation on biochemical components, including albumin, thyrotropin (TSH), total calcium and sodium in plasma. METHODS: All patients referred to an outpatient clinic for blood sampling were included in the period Nov 2011 until June 2014 (opening...... hours: 7am-3pm). Each patient's arrival time and time of blood sampling were registered. The impact of resting time and the time of day for all components was analysed using simple linear regression. The "maximum allowable bias" was used as quality indicator for the change in reference interval. RESULTS...

  7. Evaluation of some toxic metals in blood samples of smokers in ...

    African Journals Online (AJOL)

    1Forensic Chemistry Department, Naïf Arab University for Security Science, 2Micro-analytical ... Revised accepted: 11 November 2016 ... aged 20 - 58 year, whose blood samples were collected, were classified into three groups of cigarette.

  8. Device and method for automated separation of a sample of whole blood into aliquots

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  9. A duplex PCR for rapid and simultaneous detection of Brucella spp. in human blood samples.

    Science.gov (United States)

    Mirnejad, Reza; Mohamadi, Mozafar; Piranfar, Vahbeh; Mortazavi, Seied Mojtaba; Kachuei, Reza

    2013-06-01

    To design a duplex PCR for rapid and simultaneous detection of Brucella species. in human blood samples. Fifty-two peripheral bloods samples were collected from suspicious patients with brucellosis. Following DNA extraction, PCR assay were performed, using three primers that could simultaneously identify and differentiate three major species of pathogenic Brucella in humans and animals. Of the 52 peripheral bloods samples tested, 25 sample (48%) showed positive reactions in PCR. Twelve samples were positive for Brucella abortus 39 (B. abortus 39) (23%), 13 for Brucella melitensis 39 (B. melitensis 39) (25%) and 0 for Brucella ovis 39 (B. ovis 39) (0%). This work demonstrates that in case where specific primers were utilized, duplex PCR has proved to be a simple, fast, and relatively inexpensive method for simultaneous detection of important species of Brucella in clinical samples. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  10. A duplex PCR for the rapid and simultaneous detection of Brucella spp. in human blood samples

    Institute of Scientific and Technical Information of China (English)

    Reza Mirnejad; Mozafar mohamadi; Vahbeh Piranfar; Seied Mojtaba Mortazavi; Reza Kachuei

    2013-01-01

    Objective: To design a duplex PCR for rapid and simultaneous detection of Brucella species. in human blood samples. Methods: Fifty-two peripheral bloods samples were collected from suspicious patients with brucellosis. Following DNA extraction, PCR assay were performed, using three primers that could simultaneously identify and differentiate three major species of pathogenic Brucella in humans and animals. Results: Of the 52 peripheral bloods samples tested, 25 sample (48%) showed positive reactions in PCR. Twelve samples were positive for Brucella abortus (B. abortus) (23%), 13 for Brucella melitensis (B. melitensis) (25%) and 0 for Brucella ovis (B. ovis) (0%). Conclusions: This work de=monstrates that in case where specific primers were utilized, duplex PCR has proved to be a simple, fast, and relatively inexpensive method for simultaneous detection of important species of Brucella in clinical samples.

  11. Na2EDTA anticoagulant impaired blood samples from the teleost Piaractus mesopotamicus

    Directory of Open Access Journals (Sweden)

    Thaís Heloisa Vaz Farias

    2016-05-01

    Full Text Available Abstract: The present study aimed to evaluate the effects of Na heparin and Na2EDTA on blood of Piaractus mesopotamicus (360.7±42.4g, 26.4±1.0cm. Twenty fishes were sampled in two experiment trials, ten for erythrocyte fragility analysis and ten for hematologic and plasma biochemical study. The blood collected by venous-caudal puncture was fractioned and stored in anticoagulants solution: Na2EDTA 10%, Na2EDTA 3%, Na heparin 5000 IU and Na heparin 100 IU. Plasmatic levels of calcium presented in the Na2EDTA stored samples were about 80% lower than both heparin groups. Blood samples of P. mesopotamicus stored with Na2EDTA demonstrated increase in the hematocrit and MCV, and decrease in MCHC. The dose-response effect was observed in this study. The results are reinforced by the higher levels of plasmatic protein and hemolysis presented in the Na2EDTA 10% stored blood, confirming the deleterious effect of this anticoagulant treatment on the quality of blood samples. Na2EDTA is not indicated to store P. mesopotamicus blood samples, but sodium heparin at 100 IU is the most recommended anticoagulant, since this treatment presented the lower rate of alterations in the stored blood.

  12. Reliability of Gingival Blood Sample to Screen Diabetes in Dental Hospital

    OpenAIRE

    Suneetha Koneru; Rambabu Tanikonda

    2015-01-01

    Background: Early detection and treatment of diabetes mellitus may reduce the burden of diabetes and its complications. Screening of undiagnosed diabetes with gingival blood sample in patients attending to the dental hospital and to check the reliability with standard method. Methods: Five hundred and fifty new patients age ranged from 30 to 50 years were randomly selected. Of 550 patients examined, gingival blood samples of 454 patients were collected from bleeding site and analyzed with...

  13. Reproducibility of Respondent-Driven Sampling (RDS) in Repeat Surveys of Men Who have Sex with Men, Unguja, Zanzibar.

    Science.gov (United States)

    Khatib, Ahmed; Haji, Shaaban; Khamis, Maryam; Said, Christen; Khalid, Farhat; Dahoma, Mohammed; Ali, Ameir; Othman, Asha; Welty, Susie; McFarland, Willi

    2017-07-01

    To assess the reproducibility of respondent-driven sampling (RDS) in obtaining comparable samples across two survey rounds, we conducted integrated bio-behavioral surveillance surveys (IBBSS) using RDS in 2007 and 2011 among men who have sex with men (MSM) on Unguja island in Zanzibar. Differences in the two rounds were assessed by comparing RDS-adjusted population estimates, stratified estimates, and bottleneck plots. Participants in the 2011 survey round were younger (31.4 vs. 9.9% under 19 years old, p < 0.001), more likely to have tested for HIV in the last year (53.7 vs. 10.6%, p < 0.001), and less likely to have injected drugs in the last 3 months (1.0 vs. 23.2%, p < 0.001) compared to participants in the 2007 round. HIV prevalence was 12.3% in 2007 compared to 2.6% in 2011 (p < 0.001). The difference in HIV prevalence persisted after stratifying and adjusting for known differences in the two surveys rounds. Bottleneck plots suggest that recruitment chains were "trapped" in the social networks of MSM who injected drugs to a greater extent in 2007 than in 2011. We conclude that the two rounds of RDS sampled different subsets of the MSM population on Unguja, particularly with respect to inclusion of MSM within the social networks of people who inject drugs. Findings underscore the need to evaluate the reproducibility of RDS in repeated rounds of IBBSS and to develop new sampling methods for key populations at high risk for HIV in order to track the epidemic, develop evidence-based prevention and care programs, and assess their impact.

  14. High-throughput miRNA profiling of human melanoma blood samples

    Directory of Open Access Journals (Sweden)

    Rass Knuth

    2010-06-01

    Full Text Available Abstract Background MicroRNA (miRNA signatures are not only found in cancer tissue but also in blood of cancer patients. Specifically, miRNA detection in blood offers the prospect of a non-invasive analysis tool. Methods Using a microarray based approach we screened almost 900 human miRNAs to detect miRNAs that are deregulated in their expression in blood cells of melanoma patients. We analyzed 55 blood samples, including 20 samples of healthy individuals, 24 samples of melanoma patients as test set, and 11 samples of melanoma patients as independent validation set. Results A hypothesis test based approch detected 51 differentially regulated miRNAs, including 21 miRNAs that were downregulated in blood cells of melanoma patients and 30 miRNAs that were upregulated in blood cells of melanoma patients as compared to blood cells of healthy controls. The tets set and the independent validation set of the melanoma samples showed a high correlation of fold changes (0.81. Applying hierarchical clustering and principal component analysis we found that blood samples of melanoma patients and healthy individuals can be well differentiated from each other based on miRNA expression analysis. Using a subset of 16 significant deregulated miRNAs, we were able to reach a classification accuracy of 97.4%, a specificity of 95% and a sensitivity of 98.9% by supervised analysis. MiRNA microarray data were validated by qRT-PCR. Conclusions Our study provides strong evidence for miRNA expression signatures of blood cells as useful biomarkers for melanoma.

  15. Markers infectious agent in the cord blood samples public register of donors

    Directory of Open Access Journals (Sweden)

    A. B. Smoljaninov

    2014-01-01

    Full Text Available Objective. To evaluate the distribution of markers of infectious agents in umbilical cord blood samples Pokrovskij public stem cell bank donor registry for five years (2009 – 2013.Materials and Methods. 3533 plasma samples were investigatedafter selection during cord blood processing procedure for allogeneic use in Pokrovskij stem cell bank. All plasma samples were investigated in accordance with the Order of the Ministry of Health № 325 – 2003 by enzymelinked immunoassay method. In addition, during the period from November 2011 to December 2013 1030 plasma samples of umbilical cord blood were examined for the presence of HCV RNA, the RNA of HIV and HBV DNA.Results. Markers of the agents above have not been found in the plasma of 481 samples (13.6%. During the described period, no significant change in the share of samples containing antibodies to cytomegalovirus and toxoplasmosis (cytomegalovirus – 1978 samples (56%, Toxoplasma gondii – 112 samples (3.2%, 825 samples (23.4% cytomegalovirus and Toxoplasma gondii simultaneously were registered. 137 samples (3.9% were subjected to utilization in connection with detection of antibodies to HbcorAg – 116 samples (3.3%, antibodies to HCV – five samples (0.14%, and antibodies to Treponema pallidum – 16 samples (0.45%.Conclusion. The introduction of an additional method of polymerase chain reaction for the detection of nucleic acids of hepatitis viruses B, C, human immunodeficiency virus, along with study of cord blood samples by enzyme-linked immunoassay improve the quality of the control of the transmission of blood-borne infections.

  16. Application of quantitative ethanol detector (QED) test kit to measure ethanol concentration in blood samples.

    Science.gov (United States)

    Biwasaka, H; Tokuta, T; Sasaki, Y; Niitsu, H; Kumagai, R; Aoki, Y

    2001-12-27

    In this paper, the applicability of the quantitative ethanol detector (QED) test kit for screening of ethanol concentrations in blood samples was investigated. The pretreatment of blood using the sulfosalicylic acid solution and the three-way stopcock followed by membrane filtration gave satisfactory results. The ethanol concentrations in whole blood samples (n=61) determined by QED correlated well with those determined by gas chromatography; the correlation coefficient indicated 0.990. Because a high correlation coefficient (0.928) was also confirmed in trial by investigators, QED test should be highly considered for ethanol screening in forensic praxis.

  17. Postmortem measurement of caffeine in bone marrow: influence of sample location and correlation with blood concentration.

    Science.gov (United States)

    Cartiser, N; Bévalot, F; Chatenay, C; Le Meur, C; Gaillard, Y; Malicier, D; Guitton, J; Fanton, L

    2011-07-15

    Bone marrow (BM) analysis is of forensic interest in postmortem toxicological investigation in case of limited, unavailable or unusable blood samples. However, it remains difficult to determine whether a drug BM concentration is therapeutic or represents overdose, due to the lack of studies on this alternative matrix. Given the variations in BM composition in the body, sample location was suggested to be a relevant factor in assessing BM concentration. The aim of the present study was to compare postmortem caffeine concentrations in various BM sample locations and secondly to consider the correlation between BM and blood concentrations. Six BM samples (right and left side: proximal and medial femur and 5th rib) and a blood sample were collected from 21 forensic autopsies. Gas chromatography coupled to tandem mass spectrometry was performed. Blood caffeine concentrations ranged from 60 to 7591ng/mL. Femoral and rib BM concentrations ranged from 51 to 6171ng/g and 66 to 7280ng/g, respectively. Blood concentrations were always higher than BM concentrations. As a good correlation was demonstrated between blood and rib BM and between blood and the average of the four femoral BM concentrations, blood caffeine concentrations could be correctly extrapolated from BM concentrations. BM caffeine concentration was found to depend on sample location. Rib BM caffeine concentrations appeared to be systematically greater than averaged femur values and concentrations were much more variable between the 4 femur BM samples than between the 2 ribs. From a practical point of view, for caffeine analysis, rib BM appeared more relevant than femoral BM, which requires multisampling to overcome the concentration variability problem.

  18. Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training.

    Science.gov (United States)

    Cadamuro, Janne; von Meyer, Alexander; Wiedemann, Helmut; Klaus Felder, Thomas; Moser, Franziska; Kipman, Ulrike; Haschke-Becher, Elisabeth; Mrazek, Cornelia; Simundic, Ana-Maria

    2016-12-01

    Hemolytic samples are one of the most challenging preanalytical issues in laboratory medicine. Even causes leading to hemolytic specimen are various, including phlebotomy practices. Respective educational interventions as well as the reduction of the number of people involved in blood collections are claimed to influence the sample quality for the better. In our hospital 70 junior doctors were in charge of routine phlebotomy until 2012, when this task was shifted to 874 nurses, including a preceding training in phlebotomy and preanalytics. Our aim was to evaluate the impact of this training effect and the increase of people involved on sample quality. The hemolysis index (HI) of 43,875 samples was measured before (n=21,512) and after (n=22,363) the switch of blood collection responsibilities. Differences in overall hemolysis rates and the amount of plasma samples with a concentration of free hemoglobin (fHb) above 0.5 g/L and 1 g/L were calculated. Overall HI as well as the percentage of samples with an fHb concentration >0.5 g/L decreased after the responsibility for phlebotomy changed. The rate of samples with an fHb concentration >1 g/L remained unchanged. Hemolysis rates were reduced upon passing phlebotomy tasks from untrained physicians on to a trained nursing staff. We therefore conclude that the number of people performing phlebotomy seems to play a minor role, compared to the effect of a standardized training. However, whether a reduction in the number of people involved in blood collection could lead to further improvement of sample quality, remains to be investigated in future studies.

  19. Dengue-3 outbreak in Paraguay: investigations using capillary blood samples on filter paper.

    Science.gov (United States)

    Matheus, Severine; Meynard, Jean-Baptiste; Lavergne, Anne; Girod, Romain; Moua, David; Labeau, Bhety; Dussart, Philippe; Lacoste, Vincent; Deparis, Xavier

    2008-11-01

    During a dengue-3 outbreak in Paraguay at the beginning of 2007, capillary blood samples absorbed onto filter papers were collected from 44 suspected cases. These samples were subjected to three molecular and serologic tests, and 31 of the 44 samples gave a positive result by at least one of the techniques used. Molecular analyses detected the dengue-3 serotype in 22 patients and additionally the dengue-2 serotype in two patients. Therefore two different serotypes were co-circulating during this outbreak. Overall, this study validates the use of dried-blood samples for field screening investigations. Indeed, all types of laboratory studies of dengue were possible with samples consisting of a few drops of dried blood from finger pricks.

  20. Evaluation of different sized blood sampling tubes for thromboelastometry, platelet function, and platelet count

    DEFF Research Database (Denmark)

    Andreasen, Jo Bønding; Pistor-Riebold, Thea Unger; Knudsen, Ingrid Hell;

    2014-01-01

    count remained stable using a 3.6 mL tube during the entire observation period of 120 min (p=0.74), but decreased significantly after 60 min when using tubes smaller than 3.6 mL (pblood sampling tubes. Therefore, 1.8 mL tubes should...... be preferred for RoTEM® analyses in order to minimise the volume of blood drawn. With regard to platelet aggregation analysed by impedance aggregometry tubes of different size cannot be used interchangeably. If platelet count is determined later than 10 min after blood sampling using tubes containing citrate......Background: To minimise the volume of blood used for diagnostic procedures, especially in children, we investigated whether the size of sample tubes affected whole blood coagulation analyses. Methods: We included 20 healthy individuals for rotational thromboelastometry (RoTEM®) analyses...

  1. [Diagnosis of amniotic fluid embolism with blood samples by liquid-based cytology technique].

    Science.gov (United States)

    Liu, Bao-qin; Deng, Jian-qiang; Hou, An-chao; Cai, Ji-feng

    2014-12-01

    To establish the diagnosis of amniotic fluid embolism with blood samples by liquid-based cytology technique and to study the validity of method. The blood samples were collected from patients who suffered from amniotic fluid embolism. The components of amniotic fluid in blood samples were examined with blood smear by two direct smear methods (supernatant smear, sediment smear) and two liquid-based cytology methods (automatic smear, manual smear). The positive detection rate of each method was calculated. The positive detection rates of two liquid-based cytology methods (84.6% and 92.3%, respectively) were much higher than those of two direct methods (53.8% and 61.5%, respectively). The liquid-based cytology technique could improve the positive detection rate of amniotic fluid embolism.

  2. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

    Directory of Open Access Journals (Sweden)

    Cathrine Carlsen Bach

    Full Text Available In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing.Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88 provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort. We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification.For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27 for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3]. Differences were negligible in the summer for all compounds.Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

  3. The effect of eccentric exercise with blood flow restriction on neuromuscular activation, microvascular oxygenation, and the repeated bout effect.

    Science.gov (United States)

    Lauver, Jakob D; Cayot, Trent E; Rotarius, Timothy; Scheuermann, Barry W

    2017-05-01

    To examine the effect of low-intensity eccentric contractions with and without blood flow restriction (BFR) on microvascular oxygenation, neuromuscular activation, and the repeated bout effect (RBE). Participants were randomly assigned to either low-intensity (LI), low-intensity with BFR (LI-BFR), or a control (CON) group. Participants in LI and LI-BFR performed a preconditioning bout of low-intensity eccentric exercise prior to about of maximal eccentric exercise. Participants reported 24, 48, 72, and 96 h later to assess muscle damage and function. Surface electromyography (sEMG) and near-infrared spectroscopy (NIRS) were used to measure neuromuscular activation and microvascular deoxygenation (deoxy-[Hb + Mb]) and [total hemoglobin] ([THC]) during the preconditioning bout, respectively. During set-2, LI-BFR resulted in greater activation of the VM-RMS (47.7 ± 11.5% MVIC) compared to LI (67.0 ± 20.0% MVIC), as well as during set-3 (p exercise (LI 74.2 ± 14.1%, LI-BFR 75 ± 5.1%, CON 53 ± 18.6%). At 24, 48, 72, and 96 h post maximal eccentric exercise, LI and LI-BFR force deficit was not different from baseline. This study suggests that the neuromuscular and deoxygenation (i.e., metabolic stress) responses were considerably different between LI and LI-BFR groups; however, these differences did not lead to improvements in the RBE inferred by performing LI and LI-BFR.

  4. Short term soil erosion dynamics in alpine grasslands - Results from a Fallout Radionuclide repeated-sampling approach

    Science.gov (United States)

    Arata, Laura; Meusburger, Katrin; Zehringer, Markus; Ketterer, Michael E.; Mabit, Lionel; Alewell, Christine

    2016-04-01

    Improper land management and climate change has resulted in accelerated soil erosion rates in Alpine grasslands. To efficiently mitigate and control soil erosion and reduce its environmental impact in Alpine grasslands, reliable and validated methods for comprehensive data generation on its magnitude and spatial extent are mandatory. The use of conventional techniques (e.g. sediment traps, erosion pins or rainfall simulations) may be hindered by the extreme topographic and climatic conditions of the Alps. However, the application of the Fallout Radionuclides (FRNs) as soil tracers has already showed promising results in these specific agro-ecosystems. Once deposited on the ground, FRNs strongly bind to fine particles at the surface soil and move across the landscape primarily through physical processes. As such, they provide an effective track of soil and sediment redistribution. So far, applications of FRN in the Alps include 137Cs (half-life: 30.2 years) and 239+240Pu (239Pu [half-life = 24110 years] and 240Pu [half-life = 6561 years]). To investigate short term (4-5 years) erosion dynamics in the Swiss Alps, the authors applied a FRNs repeated sampling approach. Two study areas in the central Swiss Alps have been investigated: the Urseren Valley (Canton Uri), where significant land use changes occurred in the last centuries, and the Piora Valley (Canton Ticino), where land use change plays a minor role. Soil samples have been collected at potentially erosive sites along the valleys over a period of 4-5 years and measured for 137Cs and 239+240Pu activity. The inventory change between the sampling years indicates high erosion and deposition dynamics at both valleys. High spatial variability of 137Cs activities at all sites has been observed, reflecting the heterogeneous distribution of 137Cs fallout after the Chernobyl power plant accident in 1986. Finally, a new modelling technique to convert the inventory changes to quantitative estimates of soil erosion has

  5. Liquid chromatography coupled with multi-channel electrochemical detection for the determination of daidzin in rat blood sampled by an automated blood sampling system.

    Science.gov (United States)

    Tian, Feifei; Zhu, Yongxin; Long, Hong; Cregor, Meloney; Xie, Fuming; Kissinger, Candice B; Kissinger, Peter T

    2002-05-25

    Daidzin, a soy-derived biologically active natural product, has been reported to inhibit mitochondrial aldehyde dehydrogenase and suppress ethanol intake. This paper describes a method for the determination of daidzin in rat blood. After administration of daidzin, blood samples were periodically collected from awake, freely moving animals by a Culex automated blood sampler. Daidzin was extracted from 50 microl of diluted blood (blood and saline at a ratio of 1:1) with ethyl acetate. Chromatographic separation was achieved within 12 min using a microbore C(18) (100 x 1.0 mm) 3 microm column with a mobile phase containing 20 mM sodium acetate, 0.25 mM EDTA, pH 4.3, 4% methanol and 11% acetonitrile at a flow-rate of 90 microl/min. Detection was attained using a four-channel electrochemical detector with glassy carbon electrodes using oxidation potentials of +1100, 950, 850, 750 mV vs. Ag/AgCl. The limit of detection for daidzin in rat plasma was 5 ng/ml at a signal-to-noise ratio of 3:1. The extraction recovery of daidzin from rat plasma was over 74%. Linearity was obtained for the range of 25-1000 ng/ml. The intra- and inter-assay precisions were in the ranges of 2.7-6.6 and 1.9-3.7%, respectively. This method is suitable to routine in vivo monitoring of daidzin in rat plasma.

  6. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.

    Science.gov (United States)

    Jousi, Milla; Saikko, Simo; Nurmi, Jouni

    2017-09-11

    Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO

  7. Maternal red blood cell alloantibodies identified in blood samples obtained from Iranian pregnant women: the first population study in Iran.

    Science.gov (United States)

    Shahverdi, Ehsan; Moghaddam, Mostafa; Gorzin, Fateme

    2017-01-01

    The objective was to determine the frequency of occurrence of alloantibodies among pregnant women in Iran. This was a prospective cross-sectional study, which was carried out in the immunohematology reference laboratory of the Iranian Blood Transfusion Organization in Tehran, Iran, in 2008 to 2015. Screening and identification of red blood cell (RBC) alloantibodies was done on the sera of 7340 pregnant females using the standard tube method and gel column agglutination technique. Alloantibodies were identified in the serum of 332 of the 7340 (4.5%) pregnant women. A total of 410 antibodies were detected in 332 positive maternal serum samples with no previous history of blood transfusion. Anti-D was the most common antibody accounting for 70.5% of all the antibodies formed in D- women. The incidence of specific alloimmunization other than Rh group was 14.4%. We concluded that the alloimmunization rate was high in comparison with wide pattern in previous studies. In Iran, like other developing countries, alloimmunization screening tests are performed only to detect anti-D in pregnant D- women. This high rate of alloimmunization, quite possibly, is due to the fact that the majority of blood samples came from pregnant women known to have previous obstetric problems. However, we suggest that RBC antibody screening tests should be extended to all D+ women. © 2016 AABB.

  8. A content validated questionnaire for assessment of self reported venous blood sampling practices

    Directory of Open Access Journals (Sweden)

    Bölenius Karin

    2012-01-01

    Full Text Available Abstract Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  9. False negative fecal occult blood tests due to delayed sample return in colorectal cancer screening.

    NARCIS (Netherlands)

    Rossum, L.G.M. van; Rijn, A.F. van; Oijen, M.G.H. van; Fockens, P.; Laheij, R.J.F.; Verbeek, A.L.M.; Jansen, J.B.M.J.; Dekker, E.

    2009-01-01

    Delayed return of immunochemical fecal occult blood test (iFOBT) samples to a laboratory might cause false negatives because of hemoglobin degradation. Quantitative iFOBT's became increasingly more accepted in colorectal cancer screening. Therefore, we studied the effects of delay between sampling a

  10. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  11. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    Science.gov (United States)

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2017-10-04

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a pre-sample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Use of polyglycerol (PG), instead of polyethylene glycol (PEG), prevents induction of the accelerated blood clearance phenomenon against long-circulating liposomes upon repeated administration.

    Science.gov (United States)

    Abu Lila, Amr S; Nawata, Kosuke; Shimizu, Taro; Ishida, Tatsuhiro; Kiwada, Hiroshi

    2013-11-01

    The accelerated blood clearance (ABC) phenomenon accounts for the rapid systemic clearance of PEGylated nanocarriers upon repeated administrations. IgM production against the polyethylene glycol (PEG) coating in PEGylated liposomes is now known to be responsible for such unexpected pharmacokinetical alterations. The ABC phenomenon poses a remarkable clinical challenge by reducing the therapeutic efficacy of encapsulated drugs and causing harmful effects due to the altered tissue distribution pattern of the drugs. In this study, we investigated the in vivo performance of liposomes modified with polyglycerol (PG) upon repeated injection, and the in vivo therapeutic efficacy of such liposomes when they encapsulated a cytotoxic agent, doxorubicin (DXR). Repeated injection of PEG-coated liposomes in rats induced the ABC phenomenon, while repeated injection of PG-coated liposomes did not. In addition, DXR-containing PG-coated liposomes showed antitumor activity that was superior to that of free DXR and similar to that of DXR-containing PEG-coated liposomes upon repeated administration. These results indicate that polyglycerol (PG) might represent a promising alternative to PEG via enhancing the in vivo performance of liposomes by not eliciting the ABC phenomenon upon repeated administration.

  13. The effectiveness of cooling conditions on temperature of canine EDTA whole blood samples

    Directory of Open Access Journals (Sweden)

    Karen M. Tobias

    2016-11-01

    Full Text Available Background Preanalytic factors such as time and temperature can have significant effects on laboratory test results. For example, ammonium concentration will increase 31% in blood samples stored at room temperature for 30 min before centrifugation. To reduce preanalytic error, blood samples may be placed in precooled tubes and chilled on ice or in ice water baths; however, the effectiveness of these modalities in cooling blood samples has not been formally evaluated. The purpose of this study was to evaluate the effectiveness of various cooling modalities on reducing temperature of EDTA whole blood samples. Methods Pooled samples of canine EDTA whole blood were divided into two aliquots. Saline was added to one aliquot to produce a packed cell volume (PCV of 40% and to the second aliquot to produce a PCV of 20% (simulated anemia. Thirty samples from each aliquot were warmed to 37.7 °C and cooled in 2 ml allotments under one of three conditions: in ice, in ice after transfer to a precooled tube, or in an ice water bath. Temperature of each sample was recorded at one minute intervals for 15 min. Results Within treatment conditions, sample PCV had no significant effect on cooling. Cooling in ice water was significantly faster than cooling in ice only or transferring the sample to a precooled tube and cooling it on ice. Mean temperature of samples cooled in ice water was significantly lower at 15 min than mean temperatures of those cooled in ice, whether or not the tube was precooled. By 4 min, samples cooled in an ice water bath had reached mean temperatures less than 4 °C (refrigeration temperature, while samples cooled in other conditions remained above 4.0 °C for at least 11 min. For samples with a PCV of 40%, precooling the tube had no significant effect on rate of cooling on ice. For samples with a PCV of 20%, transfer to a precooled tube resulted in a significantly faster rate of cooling than direct placement of the warmed tube onto ice

  14. The effectiveness of cooling conditions on temperature of canine EDTA whole blood samples.

    Science.gov (United States)

    Tobias, Karen M; Serrano, Leslie; Sun, Xiaocun; Flatland, Bente

    2016-01-01

    Preanalytic factors such as time and temperature can have significant effects on laboratory test results. For example, ammonium concentration will increase 31% in blood samples stored at room temperature for 30 min before centrifugation. To reduce preanalytic error, blood samples may be placed in precooled tubes and chilled on ice or in ice water baths; however, the effectiveness of these modalities in cooling blood samples has not been formally evaluated. The purpose of this study was to evaluate the effectiveness of various cooling modalities on reducing temperature of EDTA whole blood samples. Pooled samples of canine EDTA whole blood were divided into two aliquots. Saline was added to one aliquot to produce a packed cell volume (PCV) of 40% and to the second aliquot to produce a PCV of 20% (simulated anemia). Thirty samples from each aliquot were warmed to 37.7 °C and cooled in 2 ml allotments under one of three conditions: in ice, in ice after transfer to a precooled tube, or in an ice water bath. Temperature of each sample was recorded at one minute intervals for 15 min. Within treatment conditions, sample PCV had no significant effect on cooling. Cooling in ice water was significantly faster than cooling in ice only or transferring the sample to a precooled tube and cooling it on ice. Mean temperature of samples cooled in ice water was significantly lower at 15 min than mean temperatures of those cooled in ice, whether or not the tube was precooled. By 4 min, samples cooled in an ice water bath had reached mean temperatures less than 4 °C (refrigeration temperature), while samples cooled in other conditions remained above 4.0 °C for at least 11 min. For samples with a PCV of 40%, precooling the tube had no significant effect on rate of cooling on ice. For samples with a PCV of 20%, transfer to a precooled tube resulted in a significantly faster rate of cooling than direct placement of the warmed tube onto ice. Canine EDTA whole blood samples cool most

  15. Rapid and reliable determination of the halogenating peroxidase activity in blood samples.

    Science.gov (United States)

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2014-12-15

    By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases.

  16. Using blood samples to estimate persistent organic pollutants and metals in green sea turtles (Chelonia mydas).

    Science.gov (United States)

    van de Merwe, Jason P; Hodge, Mary; Olszowy, Henry A; Whittier, Joan M; Lee, Shing Y

    2010-04-01

    Persistent organic pollutants (POPs) and heavy metals have been reported in a number of green turtle (Chelonia mydas) populations worldwide. However, due to ethical considerations, these studies have generally been on tissues from deceased and stranded animals. The purpose of this study was to investigate the use of blood samples to estimate the tissue contamination of live C. mydas populations. This study analysed 125 POP compounds and eight heavy metals in the blood, liver, kidney and muscle of 16 C. mydas from the Sea World Sea Turtle Rehabilitation Program, Gold Coast, Australia. Strong correlations were observed between blood and tissue concentrations for a number of POPs and metals. Furthermore, these correlations were observed over large ranges of turtle size, sex and condition. These results indicate that blood samples are a reliable non-lethal method for predicting chemical contamination in C. mydas.

  17. Optimization of loop-mediated isothermal amplification (LAMP) assays for the detection of Leishmania DNA in human blood samples.

    Science.gov (United States)

    Abbasi, Ibrahim; Kirstein, Oscar D; Hailu, Asrat; Warburg, Alon

    2016-10-01

    Visceral leishmaniasis (VL), one of the most important neglected tropical diseases, is caused by Leishmania donovani eukaryotic protozoan parasite of the genus Leishmania, the disease is prevalent mainly in the Indian sub-continent, East Africa and Brazil. VL can be diagnosed by PCR amplifying ITS1 and/or kDNA genes. The current study involved the optimization of Loop-mediated isothermal amplification (LAMP) for the detection of Leishmania DNA in human blood or tissue samples. Three LAMP systems were developed; in two of those the primers were designed based on shared regions of the ITS1 gene among different Leishmania species, while the primers for the third LAMP system were derived from a newly identified repeated region in the Leishmania genome. The LAMP tests were shown to be sufficiently sensitive to detect 0.1pg of DNA from most Leishmania species. The green nucleic acid stain SYTO16, was used here for the first time to allow real-time monitoring of LAMP amplification. The advantage of real time-LAMP using SYTO 16 over end-point LAMP product detection is discussed. The efficacy of the real time-LAMP tests for detecting Leishmania DNA in dried blood samples from volunteers living in endemic areas, was compared with that of qRT-kDNA PCR.

  18. Effects of anesthesia and blood sampling techniques on plasma metabolites and corticosterone in the rat.

    Science.gov (United States)

    Arnold, Myrtha; Langhans, Wolfgang

    2010-04-19

    Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Pssamples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Pssampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Pssampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for the design and interpretation of blood sampling experiments in laboratory animals. (c) 2010. Published by Elsevier Inc.

  19. Miniaturized blood sampling techniques to benefit reduction in mice and refinement in nonhuman primates: applications to bioanalysis in toxicity studies with antibody-drug conjugates.

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique

    2015-03-01

    Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody-drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations.

  20. Miniaturized Blood Sampling Techniques to Benefit Reduction in Mice and Refinement in Nonhuman Primates: Applications to Bioanalysis in Toxicity Studies with Antibody–Drug Conjugates

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique

    2015-01-01

    Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody–drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations. PMID:25836960

  1. An integrated approach to biomonitoring exposure to styrene and styrene-(7,8)-oxide using a repeated measurements sampling design.

    Science.gov (United States)

    Fustinoni, S; Campo, L; Manini, P; Buratti, M; Waidyanatha, S; De Palma, G; Mutti, A; Foa, V; Colombi, A; Rappaport, S M

    2008-09-01

    The aim of this work was to investigate urinary analytes and haemoglobin and albumin adducts as biomarkers of exposure to airborne styrene (Sty) and styrene-(7,8)-oxide (StyOX) and to evaluate the influence of smoking habit and genetic polymorphism of metabolic enzymes GSTM1 and GSTT1 on these biomarkers. We obtained three or four air and urine samples from each exposed worker (eight reinforced plastics workers and 13 varnish workers), one air and urine samples from 22 control workers (automobile mechanics) and one blood sample from all subjects. Median levels of exposure to Sty and StyOX, respectively, were 18.2 mg m(-3) and 133 microg m(-3) for reinforced plastics workers, 3.4 mg m(-3) and 12 microg m(-3) for varnish workers, and <0.3 mg m(-3) and <5 microg m(-3) for controls. Urinary levels of styrene, mandelic acid, phenylglyoxylic acid, phenylglycine (PHG), 4-vinylphenol (VP) and mercapturic acids (M1+M2), as well as cysteinyl adducts of serum albumin (but not those of haemoglobin) were significantly associated with exposure status (controls

  2. Genome-wide scans using archived neonatal dried blood spot samples

    Directory of Open Access Journals (Sweden)

    Wiuf Carsten

    2009-07-01

    Full Text Available Abstract Background Identification of disease susceptible genes requires access to DNA from numerous well-characterised subjects. Archived residual dried blood spot samples from national newborn screening programs may provide DNA from entire populations and medical registries the corresponding clinical information. The amount of DNA available in these samples is however rarely sufficient for reliable genome-wide scans, and whole-genome amplification may thus be necessary. This study assess the quality of DNA obtained from different amplification protocols by evaluating fidelity and robustness of the genotyping of 610,000 single nucleotide polymorphisms, using the Illumina Infinium HD Human610-Quad BeadChip. Whole-genome amplified DNA from 24 neonatal dried blood spot samples stored between 15 to 25 years was tested, and high-quality genomic DNA from 8 of the same individuals was used as reference. Results Using 3.2 mm disks from dried blood spot samples the optimal DNA-extraction and amplification protocol resulted in call-rates between 99.15% – 99.73% (mean 99.56%, N = 16, and conflicts with reference DNA in only three per 10,000 genotype calls. Conclusion Whole-genome amplified DNA from archived neonatal dried blood spot samples can be used for reliable genome-wide scans and is a cost-efficient alternative to collecting new samples.

  3. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer.

    Science.gov (United States)

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-09-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments.

  4. Multi-locus variable-number tandem repeat profiling of Salmonella enterica serovar Typhi isolates from blood cultures and gallbladder specimens from Makassar, South-Sulawesi, Indonesia.

    Directory of Open Access Journals (Sweden)

    Mochammad Hatta

    Full Text Available Multi-locus variable-number tandem repeat analysis differentiated 297 Salmonella enterica serovar Typhi blood culture isolates from Makassar in 76 genotypes and a single unique S. Typhi genotype was isolated from the cholecystectomy specimens of four patients with cholelithiasis. The high diversity in S. Typhi genotypes circulating in Makassar indicates that the number of carriers could be very large, which may complicate disease prevention and control.

  5. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  6. EVALUATION OF ZEBU NELLORE CATTLE BLOOD SAMPLES USING THE CELL-DYN 3500 HEMATOLOGY ANALYZER

    Directory of Open Access Journals (Sweden)

    Alexandre Secorun Borges

    2014-12-01

    Full Text Available The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Celldyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510 and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson’s correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semiautomated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

  7. Identifying the potential of changes to blood sample logistics using simulation.

    Science.gov (United States)

    Jørgensen, Pelle; Jacobsen, Peter; Poulsen, Jørgen Hjelm

    2013-01-01

    Using simulation as an approach to display and improve internal logistics at hospitals has great potential. This study shows how a simulation model displaying the morning blood-taking round at a Danish public hospital can be developed and utilized with the aim of improving the logistics. The focus of the simulation was to evaluate changes made to the transportation of blood samples between wards and the laboratory. The average- (AWT) and maximum waiting time (MWT) from a blood sample was drawn at the ward until it was received at the laboratory, and the distribution of arrivals of blood samples in the laboratory were used as the evaluation criteria. Four different scenarios were tested and compared with the current approach: (1) Using AGVs (mobile robots), (2) using a pneumatic tube system, (3) using porters that are called upon, or (4) using porters that come to the wards every 45 minutes. Furthermore, each of the scenarios was tested in terms of what amount of resources would give the optimal result. The simulations showed a big improvement potential in implementing a new technology/mean for transporting the blood samples. The pneumatic tube system showed the biggest potential lowering the AWT and MWT with approx. 36% and 18%, respectively. Additionally, all of the scenarios had a more even distribution of arrivals except for porters coming to the wards every 45 min. As a consequence of the results obtained in the study, the hospital decided to implement a pneumatic tube system.

  8. Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).

    Science.gov (United States)

    Head, Valerie; Eshar, David; Nau, Melissa R

    2017-03-01

    Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.

  9. Evaluation of preanalytical stability of the sample for complete blood count

    Directory of Open Access Journals (Sweden)

    Raghavendra Karanth P

    2011-09-01

    Full Text Available Objective: To evaluate the effect of time of incubation on complete blood count (CBC by using HmX analyzer. Methods: A cross sectional study was conducted at Manipal Acunova Limited, Bangalore. Ten blood samples which were stored at room temperature for CBC and differential count by using HmX analyzer were analyzed within one hour of draw and on 24, 48 and 72 hours of draw. Results: Differential count measured in an automated instrument changed over time. Conclusions: The finding of this study shows that some of CBC parameters can be changed with the incubation, therefore it is better to perform on a fresh sample.

  10. Biomarkers for monitoring pre-analytical quality variation of mRNA in blood samples.

    Directory of Open Access Journals (Sweden)

    Hui Zhang

    Full Text Available There is an increasing need for proper quality control tools in the pre-analytical phase of the molecular diagnostic workflow. The aim of the present study was to identify biomarkers for monitoring pre-analytical mRNA quality variations in two different types of blood collection tubes, K2EDTA (EDTA tubes and PAXgene Blood RNA Tubes (PAXgene tubes. These tubes are extensively used both in the diagnostic setting as well as for research biobank samples. Blood specimens collected in the two different blood collection tubes were stored for varying times at different temperatures, and microarray analysis was performed on resultant extracted RNA. A large set of potential mRNA quality biomarkers for monitoring post-phlebotomy gene expression changes and mRNA degradation in blood was identified. qPCR assays for the potential biomarkers and a set of relevant reference genes were generated and used to pre-validate a sub-set of the selected biomarkers. The assay precision of the potential qPCR based biomarkers was determined, and a final validation of the selected quality biomarkers using the developed qPCR assays and blood samples from 60 healthy additional subjects was performed. In total, four mRNA quality biomarkers (USP32, LMNA, FOSB, TNRFSF10C were successfully validated. We suggest here the use of these blood mRNA quality biomarkers for validating an experimental pre-analytical workflow. These biomarkers were further evaluated in the 2nd ring trial of the SPIDIA-RNA Program which demonstrated that these biomarkers can be used as quality control tools for mRNA analyses from blood samples.

  11. Detection of micrometastasis in peripheral blood by multi-sampling in patients with colorectal cancer

    Institute of Scientific and Technical Information of China (English)

    Xi-Wei Zhang; Hong-Yu Yang; Ping Fan; Li Yang; Guo-Yu Chen

    2005-01-01

    AIM: To evaluate the reverse transcriptase-PCR assay and multiple sampling for detection of cytokeratin-positive cells in peripheral blood of colorectal carcinoma patients and to investigate the clinical significance of micrometastasis in peripheral blood.METHODS: The expression of CK20 mRNA by RT-PCR was investigated in bone marrow, portal vein and peripheral blood in 58 colorectal cancer patients and 12 controls without known cancer. The peripheral blood was sampled twice at intervals of 3 d before operation. All the patients were followed up for one year.RESULTS: There was no positive expression of CK20mRNA in 12 volunteers. The positive expression of CK20mRNA was 77.6% (45/58) in bone marrow, and that in portal vein was 74.1% (43/58) of colorectal carcinoma patients.The positive expression of CK20mRNA cells in peripheral blood rose from 44.8% (26/58) to 69.0% (40/58) (P<0.01).The total positivity of CK20mRNA expression in peripheral blood was similar to the positivity of CK20mRNA in bone marrow and portal vein. The positive rates became higher in later clinical stages than in early stages. The CK20mRNA positive patients had a higher relapse rate within one year than the CK20mRNA negative patients.CONCLUSION: Multiple blood sampling can increase the detection of tumor cells in peripheral blood by RT-PCR for CK20mRNA in colorectal carcinoma patients and it is as sensitive and specific as that of bone marrow and portal vein. This technique may be reliable and convenient to diagnose micrometastasis of colorectal carcinoma and has an important significance in determining the prognosis of cancer patients.

  12. The future of doping control in athletes. Issues related to blood sampling.

    Science.gov (United States)

    Birkeland, K I; Hemmersbach, P

    1999-07-01

    When current antidoping programmes were developed, the most frequently used doping agents were xenobiotics, such as stimulants and anabolic steroids, that are readily detectable in urine with the use of gas chromatography and mass spectrometry. As control of traditional doping agents became effective, some athletes turned to other means to improve performance, including blood doping and the application of recombinant peptide hormones such as erythropoietin and growth hormone. Doping with these agents is not easily detected in urine samples, and therefore new strategies must be developed as a supplement to those already in use. Such strategies will probably include analysing blood samples, as several of the most promising methods that are able to detect modern doping agents use blood as the analytical matrix. Non-autologous blood doping results in an admixture of self and foreign red blood cells that can be detected in a blood sample with the methods available. Methods to indicate doping with erythropoietin include the indirect finding of an elevated level of soluble transferrin receptor in serum, or a direct demonstration of a shift from the normal to an abnormal spectrum of erythropoietin isoforms. To indicate doping with growth hormone, a set of serum parameters including insulin growth factors and their binding proteins are under investigation as indirect evidence. A direct method using isotopic differences between endogenous and recombinant growth hormones is being investigated. A similar method has been established to detect the administration of testosterone esters. Several legal and ethical questions must be solved before blood sampling can become a part of routine doping control, but the major ethical question is whether sport can continue as today without proper methods to detect many modern doping agents.

  13. Risk factors for Salmonella infection in fattening pigs - an evaluation of blood and meat juice samples.

    Science.gov (United States)

    Hotes, S; Kemper, N; Traulsen, I; Rave, G; Krieter, J

    2010-11-01

    The main objective of this study was to analyse potential herd-level factors associated with the detection of Salmonella antibodies in fattening pigs. Two independent datasets, consisting of blood and meat juice samples respectively, were used. Additional information about husbandry, management and hygiene conditions was collected by questionnaire for both datasets. The serological analysis showed that 13.8% of the blood samples and 15.7% of the meat juice samples had to be classified as Salmonella-positive. Logistic-regression models were used to assess statistically significant risk factors associated with a positive sample result. The results of the statistical blood sample analysis showed that the application of antibiotics increased the odds ratio (OR) by a factor of 5.21 (P meat juice samples revealed the importance of feed aspects. The chance of obtaining a positive meat juice sample increased by a factor of 3.52 (P flour. It also became clear that liquid feeding should be preferred to dry feeding (OR = 0.33, P meat juice model revealed that the latter was less powerful because data structure was less detailed. The expansion of data acquisition might solve these problems and improve the suitability of QS monitoring data for risk factor analyses. © 2010 Blackwell Verlag GmbH.

  14. Detection of the BLV provirus from nasal secretion and saliva samples using BLV-CoCoMo-qPCR-2: Comparison with blood samples from the same cattle.

    Science.gov (United States)

    Yuan, Yuan; Kitamura-Muramatsu, Yuri; Saito, Susumu; Ishizaki, Hiroshi; Nakano, Miwa; Haga, Satoshi; Matoba, Kazuhiro; Ohno, Ayumu; Murakami, Hironobu; Takeshima, Shin-Nosuke; Aida, Yoko

    2015-12-02

    Bovine leukemia virus (BLV) induces enzootic bovine leukosis, which is the most common neoplastic disease in cattle. Sero-epidemiological studies show that BLV infection occurs worldwide. Direct contact between infected and uninfected cattle is thought to be one of the risk factors for BLV transmission. Contact transmission occurs via a mixture of natural sources, blood, and exudates. To confirm that BLV provirus is detectable in these samples, matched blood, nasal secretion, and saliva samples were collected from 50 cattle, and genomic DNA was extracted. BLV-CoCoMo-qPCR-2, an assay developed for the highly sensitive detection of BLV, was then used to measure the proviral load in blood (n=50), nasal secretions (n=48), and saliva (n=47) samples. The results showed that 35 blood samples, 14 nasal secretion samples, and 6 saliva samples were positive for the BLV provirus. Matched blood samples from cattle that were positive for the BLV provirus (either in nasal secretion or saliva samples) were also positive in their blood. The proviral load in the positive blood samples was >14,000 (copies/1×10(5) cells). Thus, even though the proviral load in the nasal secretion and saliva samples was much lower (<380 copies/1×10(5) cells) than that in the peripheral blood, prolonged direct contact between infected and healthy cattle may be considered as a risk factor for BLV transmission.

  15. Effective prevention of pseudothrombocytopenia in feline blood samples with the prostaglandin I2 analogue Iloprost.

    Science.gov (United States)

    Riond, Barbara; Waßmuth, Andrea Katharina; Hartnack, Sonja; Hofmann-Lehmann, Regina; Lutz, Hans

    2015-08-06

    In vitro platelet aggregation in feline blood samples is a well-known phenomenon in veterinary clinical laboratories resulting in high numbers of pseudothrombocytopenia. Several attempts have been made to prevent or dissolve platelet aggregates in feline blood samples and to increase the reliability of feline platelet counts. Prostaglandin I2 (PGI2) is the most powerful endogenous inhibitor of platelet aggregation but unstable. Iloprost is a stable PGI2 analogue. The aims of the present study were (1) to evaluate the anti-aggregatory effect of Iloprost on feline platelet counts and to determine a useful concentration to inhibit platelet aggregation in EDTA samples from clinically healthy cats, (2) to investigate the effect of Iloprost on hematological blood parameters, and (3) to determine stability of Iloprost in K3-EDTA tubes for up to 16 weeks. From 20 clinically healthy cats blood was drawn from the jugular vein and immediately distributed in a 1.3 ml K3-EDTA tube, and two 1.3 ml K3-EDTA tubes containing 20 ng and 200 ng Iloprost, respectively. A complete blood cell count was performed on the Sysmex XT-2000iV and the Mythic 18 on eight consecutive time points after collection. Blood smears were evaluated for the presence of PLT aggregates. In the absence of Iloprost, pseudothrombocytopenia was observed in 50% of the investigated samples that led to significantly decreased optical PLT counts by a mean of 105 x10(3)/μl, which could be prevented by the addition of 1 μL (20 ng) Iloprost leading to an increase in PLT counts by a mean of 108 x10(3)/μl. This is the first study showing an anti-aggregatory effect of the PGI2-analogue Iloprost in feline EDTA blood. In all clinically healthy cats investigated, pseudothrombocytopenia was prevented by adding Iloprost to EDTA tubes prior to blood collection. Furthermore, Iloprost was very useful in preventing falsely increased WBC counts in samples with platelet aggregates analyzed on impedance-based hematological

  16. Sample pretreatment microfluidic chip for DNA extraction from rat peripheral blood

    Institute of Scientific and Technical Information of China (English)

    CHEN Xing; CUI Dafu; LIU Changchun; LI Hui; ZHAO Weixing

    2007-01-01

    A sample pretreatment microfluidic chip was described based on the principle of solid phase extraction and micro electro mechanical system technology.Oxidized porous silicon with the large surface area as the solid phase matrix for absorption of DNA from a biological sample can greatly improve the DNA yield.The factors that could affect the DNA yield were analyzed and the preparation technology and the experiment procedure were improved.The DNA purification process from the rat peripheral blood can be achieved and the DNA yield is 24 ng/(μL whole blood),which can reach the level of the commercial DNA purification kits.Furthermore,the DNA extracted from the whole blood can be amplified by polymerase chain reaction,which can achieve a high efficiency of the amplification.

  17. Adapting dried blood spot sampling for an anti-therapeutic antibody immunogenicity assay.

    Science.gov (United States)

    Xiang, Yuhong; Welch, Mackenzie; Amaravadi, Lakshmi; Stebbins, Christopher

    2013-07-31

    Dried blood spot sampling is a microvolume sampling technique with many potential advantages. It allows for easier handling and less expensive shipment and storage of biological samples. Additionally, it can provide ethical benefits in the pre-clinical setting through a reduction in animal usage by allowing intensive serial sample collection from the same animals. In the clinical setting, ease of sample collection, greater flexibility of sample storage, and shipping are distinct advantages. These advantages can enhance preclinical and clinical data quality, where immunogenicity monitoring plays an important role in the interpretation of pharmacokinetic data. To date, a method for usage of dried blood spot sampling with an immunogenicity assay has not been published. Herein we demonstrate that the measurement of anti-drug antibodies (ADA) using DBS was comparable to traditional methods in terms of reproducibility, assay sensitivity and drug tolerance. The data demonstrate that DBS is a viable sample collection method, and in some cases may be preferred, over classic serum or plasma sampling for antidrug antibody assays. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Reliability of gingival blood sample to screen diabetes in dental hospital

    Directory of Open Access Journals (Sweden)

    Suneetha Koneru

    2015-01-01

    Conclusions: The results of the present study showed blood obtained from periodontal pocket probing is a reliable sample to screen diabetes in periodontal disease population. Early diagnosis of diabetes in the dental hospitals can help improve the patient′s oral health and overall health status by helping patients avoid or reduce complications from diabetes.

  19. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  20. Stability of HE4 and CA125 in blood samples from patients diagnosed with ovarian cancer

    DEFF Research Database (Denmark)

    Sandhu, Noreen; Karlsen, Mona A; Høgdall, Claus

    2014-01-01

    OBJECTIVE: To investigate the influence of handling and storage on HE4 and CA125 serum and EDTA plasma levels to clarify any important consequences for a clinical setting. METHODS: Blood samples from 13 ovarian cancer (OC) patients were collected and allowed to clot or sediment for up to 72 hours...

  1. [Automated serial diagnosis of donor blood samples. Ergonomic and economic organization structure].

    Science.gov (United States)

    Stoll, T; Fischer-Fröhlich, C L; Mayer, G; Hanfland, P

    1990-01-01

    A comprehensive computer-aided administration-system for blood-donors is presented. Ciphered informations of barcode-labels allow the automatic and nevertheless selective pipetting of samples by pipetting-robots. Self-acting analysis-results are transferred to a host-computer in order to actualize a donor data-base.

  2. Highly specific quantification of ergotamine in urine, blood, and hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Favretto, Donata; Frison, Giampietro; Vogliardi, Susanna; Ferrara, Santo Davide

    2007-06-01

    Ergotamine has been used for therapeutic purposes since the 1950s, usually to treat vascular headache. It is highly toxic and in large, repeated doses can produce all the symptoms of ergot poisoning. A selective and sensitive method, based on liquid chromatography-tandem mass spectrometry (LC-MS2), has been developed for quantifying ergotamine in biological fluids with use of a quick and easy sample preparation. Ergotamine and the internal standard, trideuterated lysergic acid diethylamide, were extracted from human urine, blood, and hair by means of liquid-liquid extraction at alkaline pH. Gradient elution on a cyanopropyl column was used for chromatographic separation. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method was validated and successfully applied to a case of iatrogenic ergotism resulting from the intake of ergotamine tartrate for treating headache. For the first time, ergotamine was identified and quantified in hair. The ergotamine concentrations measured were 320 pg/mL in blood, 100 pg/mL in urine, 24 pg/mg in proximal hair, and 15 pg/mg in distal hair.

  3. Effect of Repeated Whole Blood Donations on Aerobic Capacity and Hemoglobin Mass in Moderately Trained Male Subjects: A Randomized Controlled Trial.

    Science.gov (United States)

    Meurrens, Julie; Steiner, Thomas; Ponette, Jonathan; Janssen, Hans Antonius; Ramaekers, Monique; Wehrlin, Jon Peter; Vandekerckhove, Philippe; Deldicque, Louise

    2016-12-01

    The aims of the present study were to investigate the impact of three whole blood donations on endurance capacity and hematological parameters and to determine the duration to fully recover initial endurance capacity and hematological parameters after each donation. Twenty-four moderately trained subjects were randomly divided in a donation (n = 16) and a placebo (n = 8) group. Each of the three donations was interspersed by 3 months, and the recovery of endurance capacity and hematological parameters was monitored up to 1 month after donation. Maximal power output, peak oxygen consumption, and hemoglobin mass decreased (p blood donation with a maximal decrease of 4, 10, and 7%, respectively. Hematocrit, hemoglobin concentration, ferritin, and red blood cell count (RBC), all key hematological parameters for oxygen transport, were lowered by a single donation (p donations (p blood donation was 11% for hematocrit, 10% for hemoglobin concentration, 50% for ferritin, and 12% for RBC (p donation group. Maximal, but not submaximal, endurance capacity was altered after blood donation in moderately trained people and the expected increase in capacity after multiple maximal exercise tests was not present when repeating whole blood donations.

  4. A new approach to determining cholinesterase activities in samples of whole blood.

    Science.gov (United States)

    Augustinsson, K B; Eriksson, H; Faijersson, Y

    1978-10-16

    A sensitive method, especially suitable for clinical laboratories, for the routine determination of cholinesterase activities in whole blood is presented. This method is based on the hydrolysis of propionylthiocholine and the spectrophotometric determination of the thiocholine produced by reaction with 4,4'-dithiodipyridine. The reaction product 4-thiopyridone has an absorption maximum at 324 nm, so that measurement in the presence of hemoglobin is possible. Propionylthiocholine is used at the substrate for both plasma butyrylcholinesterase and erythrocyte acetylcholinesterase. These two enzymes, in the relative amounts at which they are present in human blood, split this ester at about the same rate. Consequently, a first determination gives the total activity of which each individual activity is about 50%. A second determination in the presence of a selective inhibitor ("Astra 1397") for plasma butyrylcholinesterase gives the activity of the erythrocyte acetylcholinesterase. The difference between the two values represents the activity of the plasma enzyme. The validity of the method and the reliability of the results were checked with each blood sample in two ways: (1) by determining the activities of whole blood with an earlier gasometric technique which uses blood sample dried on filter paper; and (2) by measuring the activities in separated plasma and erythrocyte hemolysate eith propionylthiocholine as the substrate.

  5. Barrier screens: a method to sample blood-fed and host-seeking exophilic mosquitoes

    Directory of Open Access Journals (Sweden)

    Burkot Thomas R

    2013-02-01

    Full Text Available Abstract Background Determining the proportion of blood meals on humans by outdoor-feeding and resting mosquitoes is challenging. This is largely due to the difficulty of finding an adequate and unbiased sample of resting, engorged mosquitoes to enable the identification of host blood meal sources. This is particularly difficult in the south-west Pacific countries of Indonesia, the Solomon Islands and Papua New Guinea where thick vegetation constitutes the primary resting sites for the exophilic mosquitoes that are the primary malaria and filariasis vectors. Methods Barrier screens of shade-cloth netting attached to bamboo poles were constructed between villages and likely areas where mosquitoes might seek blood meals or rest. Flying mosquitoes, obstructed by the barrier screens, would temporarily stop and could then be captured by aspiration at hourly intervals throughout the night. Results In the three countries where this method was evaluated, blood-fed females of Anopheles farauti, Anopheles bancroftii, Anopheles longirostris, Anopheles sundaicus, Anopheles vagus, Anopheles kochi, Anopheles annularis, Anopheles tessellatus, Culex vishnui, Culex quinquefasciatus and Mansonia spp were collected while resting on the barrier screens. In addition, female Anopheles punctulatus and Armigeres spp as well as male An. farauti, Cx. vishnui, Cx. quinquefasciatus and Aedes species were similarly captured. Conclusions Building barrier screens as temporary resting sites in areas where mosquitoes were likely to fly was an extremely time-effective method for collecting an unbiased representative sample of engorged mosquitoes for determining the human blood index.

  6. Whole genome transcript profiling from fingerstick blood samples: a comparison and feasibility study

    Directory of Open Access Journals (Sweden)

    Williams Adam R

    2009-12-01

    Full Text Available Abstract Background Whole genome gene expression profiling has revolutionized research in the past decade especially with the advent of microarrays. Recently, there have been significant improvements in whole blood RNA isolation techniques which, through stabilization of RNA at the time of sample collection, avoid bias and artifacts introduced during sample handling. Despite these improvements, current human whole blood RNA stabilization/isolation kits are limited by the requirement of a venous blood sample of at least 2.5 mL. While fingerstick blood collection has been used for many different assays, there has yet to be a kit developed to isolate high quality RNA for use in gene expression studies from such small human samples. The clinical and field testing advantages of obtaining reliable and reproducible gene expression data from a fingerstick are many; it is less invasive, time saving, more mobile, and eliminates the need of a trained phlebotomist. Furthermore, this method could also be employed in small animal studies, i.e. mice, where larger sample collections often require sacrificing the animal. In this study, we offer a rapid and simple method to extract sufficient amounts of high quality total RNA from approximately 70 μl of whole blood collected via a fingerstick using a modified protocol of the commercially available Qiagen PAXgene RNA Blood Kit. Results From two sets of fingerstick collections, about 70 uL whole blood collected via finger lancet and capillary tube, we recovered an average of 252.6 ng total RNA with an average RIN of 9.3. The post-amplification yields for 50 ng of total RNA averaged at 7.0 ug cDNA. The cDNA hybridized to Affymetrix HG-U133 Plus 2.0 GeneChips had an average % Present call of 52.5%. Both fingerstick collections were highly correlated with r2 values ranging from 0.94 to 0.97. Similarly both fingerstick collections were highly correlated to the venous collection with r2 values ranging from 0.88 to 0

  7. Stability of heparin blood samples during transport based on defined pre-analytical quality goals

    DEFF Research Database (Denmark)

    Jensen, Esther A; Stahl, Marta; Brandslund, Ivan

    2008-01-01

    impact on the quality of results, we wanted to study which combination of transport conditions could fulfil our pre-defined goals for maximum allowable error. METHODS: Samples from 406 patients from nine general practitioners (GPs) in two Danish counties were sent to two hospitals for analyses, during......, centrifuged and separated at the doctor's office within 45-60 min. This sample was considered as the best estimate of a comparison value. RESULTS: The pre-set quality goals were fulfilled for all the investigated components for samples transported to hospital by courier either as whole blood or as "on gel......" after centrifugation, as long as the samples were stored at 20-25 degrees C and centrifuged/analysed within 5-6 h. A total of 4% of the samples sent by mail had mismatched identity, probably due to plasma being transferred to a new tube. CONCLUSIONS: Samples can be sent as unprocessed anticoagulated...

  8. Using improved serial blood sampling method of mice to study pharmacokinetics and drug-drug interaction.

    Science.gov (United States)

    Watanabe, Ayahisa; Watari, Ryosuke; Ogawa, Keiko; Shimizu, Ryosuke; Tanaka, Yukari; Takai, Nozomi; Nezasa, Ken-ichi; Yamaguchi, Yoshitaka

    2015-03-01

    In pharmacokinetic evaluation of mice, using serial sampling methods rather than a terminal blood sampling method could reduce the number of animals needed and lead to more reliable data by excluding individual differences. In addition, using serial sampling methods can be valuable for evaluation of the drug-drug interaction (DDI) potential of drug candidates. In this study, we established an improved method for serially sampling the blood from one mouse by only one incision of the lateral tail vein, and investigated whether our method could be adapted to pharmacokinetic and DDI studies. After intravenous and oral administration of ibuprofen and fexofenadine (BCS class II and III), the plasma concentration and pharmacokinetic parameters were evaluated by our method and a terminal blood sampling method, with the result that both methods gave comparable results (ibuprofen: 63.8 ± 4.0% and 64.4%, fexofenadine: 6.5 ± 0.7% and 7.9%, respectively, in bioavailability). In addition, our method could be adapted to DDI study for cytochrome P450 and organic anion transporting polypeptide inhibition. These results demonstrate that our method can be useful for pharmacokinetic evaluation from the perspective of reliable data acquisition as well as easy handling and low stress to mice and improve the quality of pharmacokinetic and DDI studies. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  9. Fabrication and Characterization of a Microfluidic Device to Ultrapurify Blood Samples

    KAUST Repository

    Tallerico, Marco

    2015-05-04

    The improvement of blood cell sorting techniques in recent years have attracted the attention of many researchers due to the possible benefits that these methods can lead in biology, regenerative medicine, materials science and therapeutic area. In this work a cell sorting technique based on filtration is described. The separation occurs by means of a microfluidic device, suitably designed, manufactured and tested, that is connected to an external experimental set-up. The fabrication process can be divided in two parts: at first it is described the manufacturing process of a filtering membrane, with holes of specific size that allow the passage of only certain cell types. Following the microfluidic device is fabricated through the mechanical micromilling. The membrane and the microdevice are suitably bonded and tested by means of an external connection with syringe pumps that inject blood samples at specific flow rates. The device is designed to separate blood cells and tumor cells only by using differences in size and shape. In particular during the first experiments red blood cells and platelets are sorted from white blood cells; in the other experiments red blood cells and platelets are separated from white blood cells and tumor cells. The microdevice has proven to be very efficient, in fact a capture efficiency of 99% is achieved. For this reason it could be used in identification and isolation of circulating tumor cells, a very rare cancer cell type whose presence in the bloodstream could be symptom of future solid tumor formation. The various experiments have also demonstrated that tumor cells survive even after the separation treatment, and then the suffered stress during the sorting process does not harm the biological sample.

  10. Heel blood sampling in European neonatal intensive care units: compliance with pain management guidelines

    DEFF Research Database (Denmark)

    Losacco, Valentina; Cuttini, Marina; Greisen, Gorm

    2011-01-01

    Objective To describe the use of heel blood sampling and non-pharmacological analgesia in a large representative sample of neonatal intensive care units (NICUs) in eight European countries, and compare their self-reported practices with evidence-based recommendations. Methods Information on use...... admissions per year were included in this analysis. Results Use of heel blood sampling appeared widespread. Most units in the Netherlands, UK, Denmark, Sweden and France predominantly adopted mechanical devices, while manual lance was still in use in the other countries. The two Scandinavian countries...... and France were the most likely, and Belgium and Spain the least likely to employ recommended combinations of evidence-based pain management measures. Conclusions Heel puncture is a common procedure in preterm neonates, but pain appears inadequately treated in many units and countries. Better compliance...

  11. Analysis of whole blood samples with low gas flow inductively coupled plasma-optical emission spectrometry.

    Science.gov (United States)

    Nowak, Sascha; Künnemeyer, Jens; Terborg, Lydia; Trümpler, Stefan; Günsel, Andreas; Wiesmüller, Gerhard A; Karst, Uwe; Buscher, Wolfgang

    2015-01-01

    Low gas flow ICP-OES with a total argon consumption below 0.7 L/min is introduced for the analysis of trace elements in blood samples to investigate the influence of samples containing an organic solvent in a demanding matrix on the performance of this plasma for the first time. Therefore, gadolinium was determined in human plasma samples and mercury in red blood cells, human plasma, and precipitated plasma protein fraction. Limits of detection (LOD) were determined to be in the low microgram per liter range for the analytes and the accuracy of the method was assessed by comparison with a conventional Fassel-type torch-based ICP-OES. It was proven that the low gas flow ICP-OES leads to comparable results with the instrument based on the Fassel-type torch.

  12. Test-retest repeatability of myocardial blood flow and infarct size using {sup 11}C-acetate micro-PET imaging in mice

    Energy Technology Data Exchange (ETDEWEB)

    Croteau, Etienne; Renaud, Jennifer M.; McDonald, Matthew; Klein, Ran; DaSilva, Jean N.; Beanlands, Rob S.B.; DeKemp, Robert A. [University of Ottawa Heart Institute, National Cardiac PET Centre, Ottawa, Ontario (Canada)

    2015-09-15

    Global and regional responses of absolute myocardial blood flow index (iMBF) are used as surrogate markers to assess response to therapies in coronary artery disease. In this study, we assessed the test-retest repeatability of iMBF imaging, and the accuracy of infarct sizing in mice using {sup 11}C-acetate PET. {sup 11}C-Acetate cardiac PET images were acquired in healthy controls, endothelial nitric oxide synthase (eNOS) knockout transgenic mice, and mice after myocardial infarction (MI) to estimate global and regional iMBF, and myocardial infarct size compared to {sup 18}F-FDG PET and ex-vivo histology results. Global test-retest iMBF values had good coefficients of repeatability (CR) in healthy mice, eNOS knockout mice and normally perfused regions in MI mice (CR = 1.6, 2.0 and 1.5 mL/min/g, respectively). Infarct size measured on {sup 11}C-acetate iMBF images was also repeatable (CR = 17 %) and showed a good correlation with the infarct sizes found on {sup 18}F-FDG PET and histopathology (r{sup 2} > 0.77; p < 0.05). {sup 11}C-Acetate micro-PET assessment of iMBF and infarct size is repeatable and suitable for serial investigation of coronary artery disease progression and therapy. (orig.)

  13. Power and sample size for the S:T repeated measures design combined with a linear mixed-effects model allowing for missing data.

    Science.gov (United States)

    Tango, Toshiro

    2017-02-13

    Tango (Biostatistics 2016) proposed a new repeated measures design called the S:T repeated measures design, combined with generalized linear mixed-effects models and sample size calculations for a test of the average treatment effect that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size compared with the simple pre-post design. In this article, we present formulas for calculating power and sample sizes for a test of the average treatment effect allowing for missing data within the framework of the S:T repeated measures design with a continuous response variable combined with a linear mixed-effects model. Examples are provided to illustrate the use of these formulas.

  14. Genetic Characterization of Atypical Mansonella (Mansonella) ozzardi Microfilariae in Human Blood Samples from Northeastern Peru

    Science.gov (United States)

    Marcos, Luis A.; Arrospide, Nancy; Recuenco, Sergio; Cabezas, Cesar; Weil, Gary J.; Fischer, Peter U.

    2012-01-01

    DNA sequence comparisons are useful for characterizing proposed new parasite species or strains. Microfilariae with an atypical arrangement of nuclei behind the cephalic space have been recently described in human blood samples from the Amazon region of Peru. Three blood specimens containing atypical microfilariae were genetically characterized using three DNA markers (5S ribosomal DNA, 12S ribosomal DNA, and cytochrome oxidase I). All atypical microfilariae were clustered into the Mansonella group and indistinguishable from M. ozzardi based on these DNA markers. PMID:22826497

  15. Automated processing of whole blood samples into microliter aliquots of plasma

    OpenAIRE

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 μl can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially i...

  16. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters.

    Science.gov (United States)

    Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla

    2013-01-01

    A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9-3.9 and random effect RR 1.07; 95% CI = 1.06-1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7-5.1 and RR 1.32; 95% CI = 1.24-1.40). Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration.

  17. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    DEFF Research Database (Denmark)

    Teilmann, Anne Charlotte; Nygaard Madsen, Andreas; Holst, Birgitte

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling...... using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two...... time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were...

  18. Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis

    Directory of Open Access Journals (Sweden)

    Mankhambo Limangeni A

    2007-09-01

    Full Text Available Abstract Background The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. Results Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02. Conclusion We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis.

  19. Ten Repeat Collections for Urinary Iodine from Spot Samples or 24-Hour Samples Are Needed to Reliably Estimate Individual Iodine Status in Women

    NARCIS (Netherlands)

    Konig, F.; Andersson, M.; Hotz, K.; Aeberli, I.; Zimmermann, M.B.

    2011-01-01

    Although the median urinary iodine concentration (UIC) is a good indicator of iodine status in populations, there is no established biomarker for individual iodine status. If the UIC were to be used to assess individuals, it is unclear how many repeat urine collections would be needed and if the col

  20. Electrokinetic sample injection for high-sensitivity CZE (part 2): improving the quantitative repeatability and application of electrokinetic supercharging-CZE to the detection of atmospheric electrolytes.

    Science.gov (United States)

    Xu, Zhongqi; Koshimidzu, Eiji; Hirokawa, Takeshi

    2009-10-01

    Electrokinetic supercharging (EKS) is defined as a technique that combines electrokinetic sample injection with transient ITP. Quantitative repeatability of EKS-CZE and the other CE methods using electrokinetic sample injection process is usually inferior in comparison with the CE methods using hydrodynamic or hydrostatic injection. This is due to some effects, such as the temperature change and the convection of the sample solution in the reservoir, as well as the change of the distance between an electrode and a capillary end (D(ec)). In particular, we have found that the D(ec) change might most seriously affect the repeatability, especially when the electrode is a thin Pt wire that could be unintentionally bent during sampling. By using a Teflon spacer to fix D(ec) to 1.1 mm, the RSD of peak area (n=5) was decreased from 20 to 3.4% in EKS-CZE for several metal cations. This D(ec) dependence of the sample amount injected was supported by computer simulation using CFD-ACE+ software. The improved repeatability (down to 5.1% at n=5, averaged RSD for Co(2+), Li(+), Ni(2+), Zn(2+) and Pb(2+)) was also experimentally attained by increasing the D(ec) to ca. 20 mm, which was also effective to obtain high sensitivity. Since the temperature and the convection effects on the repeatability are comparatively small in a proper laboratory environment, these effects were estimated from the EKS-CZE experiments using conditions such as warming and agitating the sample solution during EKS process. Finally, EKS-CZE was applied to the detection of ions from atmospheric electrolytes in high-purity water exposed to ambient air for 2 h. The microgram per liter levels of anions (chloride, sulfate, nitrate, formate, acetate and lactate) and cations (ammonium, calcium, sodium and magnesium) could be detected using conventional UV detector.

  1. Highly Effective DNA Extraction Method from Fresh, Frozen, Dried and Clotted Blood Samples

    Directory of Open Access Journals (Sweden)

    Jaleh Barar

    2011-09-01

    Full Text Available Introduction: Today, with the tremendous potential of genomics and other recent advances in science, the role of science to improve reliable DNA extraction methods is more relevant than ever before. The ideal process for genomic DNA extraction demands high quantities of pure, integral and intact genomic DNA (gDNA from the sample with minimal co-extraction of inhibitors of downstream processes. Here, we report the development of a very rapid, less-hazardous, and high throughput protocol for extracting of high quality DNA from blood samples. Methods: Dried, clotted and ethylene diamine tetra-acetic acid (EDTA treated fresh and frozen blood samples were extracted using this method in which the quality and integrity of the extracted DNA were corroborated by agarose gel electrophoresis, PCR reaction and DNA digestion using restricted enzyme. The UV spectrophotometric and gel electrophoresis analysis resulted in high A260/A280 ratio (>1.8 with high intactness of DNA. Results: PCR and DNA digestion experiments indicated that the final solutions of extracted DNA contained no inhibitory substances, which confirms that the isolated DNA is of good quality. Conclusion: The high quality and quantity of current method, no enzymatic processing and accordingly its low cost, make it appropriate for DNA extraction not only from human but also from animal blood samples in any molecular biology labs.

  2. Blood biochemical markers of bone turnover: pre-analytical and technical aspects of sample collection and handling.

    Science.gov (United States)

    Lombardi, Giovanni; Lanteri, Patrizia; Colombini, Alessandra; Banfi, Giuseppe

    2012-02-03

    Casual or systematic errors occurring in pre-analytical, analytical or post-analytical phases influence laboratory test results. The areas where pre-analytical phase errors most often arise are: timing of specimen collection; selection of specimen type; and time and temperature of storage/transport. Bone turnover markers are clinically useful in evaluating bone metabolism. Although unquestionably valuable tools, little is known about the pre-analytical precautions for their correct use and there is no consensus on kind of sample, or storage time and temperature before analysis. Moreover, biological variability, because of uncontrollable and controllable factors, will affect pre-analytical variability. Serum should be preferred to simplify blood drawing; therefore, only one tube should be used for the analysis of all bone markers. Short-term storage at 4°C may be advisable to preserve stability, immediate storage at -70°C is recommended for longer periods, while avoiding repeated freeze-thawing cycles. Sampling should be performed in the morning in fasting subjects who have abstained from physical exercise for 24 h. This review aimed to give a knowledge update on pre-analytical phase precautions in performing bone turnover marker measurement.

  3. Distribution of blood types in a sample of 245 New Zealand non-purebred cats.

    Science.gov (United States)

    Cattin, R P

    2016-05-01

    To determine the distribution of feline blood types in a sample of non-pedigree, domestic cats in New Zealand, whether a difference exists in this distribution between domestic short haired and domestic long haired cats, and between the North and South Islands of New Zealand; and to calculate the risk of a random blood transfusion causing a severe transfusion reaction, and the risk of a random mating producing kittens susceptible to neonatal isoerythrolysis. The results of 245 blood typing tests in non-pedigree cats performed at the New Zealand Veterinary Pathology (NZVP) and Gribbles Veterinary Pathology laboratories between the beginning of 2009 and the end of 2014 were retrospectively collated and analysed. Cats that were identified as domestic short or long haired were included. For the cats tested at Gribbles Veterinary Pathology 62 were from the North Island, and 27 from the South Island. The blood type distribution differed between samples from the two laboratories (p=0.029), but not between domestic short and long haired cats (p=0.50), or between the North and South Islands (p=0.76). Of the 89 cats tested at Gribbles Veterinary Pathology, 70 (79%) were type A, 18 (20%) type B, and 1 (1%) type AB; for NZVP 139/156 (89.1%) cats were type A, 16 (10.3%) type B, and 1 (0.6%) type AB. It was estimated that 18.3-31.9% of random blood transfusions would be at risk of a transfusion reaction, and neonatal isoerythrolysis would be a risk in 9.2-16.1% of random matings between non-pedigree cats. The results from this study suggest that there is a high risk of complications for a random blood transfusion between non-purebred cats in New Zealand. Neonatal isoerythrolysis should be considered an important differential diagnosis in illness or mortality in kittens during the first days of life.

  4. Time impact on non-activated and kaolin-activated blood samples in thromboelastography.

    Science.gov (United States)

    Durila, Miroslav; Lukáš, Pavel; Bronský, Jiří; Cvachovec, Karel

    2015-04-15

    The correct methodology of thrombelastography might be influenced by elapsing time. In our study we investigated kaolin activated citrated samples together with non-activated citrated samples in relation to the elapsed times of 0, 15 and 30 minutes to compare both methods and to find out if there is an impact of time on results of thrombelastography. Blood samples obtained from 10 healthy volunteers were analyzed after 0, 15 and 30 minutes from sampling with kaolin activation and without activation. Then the results were analysed and compared between the non-activated and the kaolin-activated method. All blood samples became more hypercoagulable with the time elapsing, both in non-activated and kaolin-activated samples and differences between both groups were found statistically and clinically significant after only 0 minutes. The non-activated citrated method seems to be reliable and suitable for thrombelastography in non-emergency cases (planned surgical procedures) when we have time to wait 15-30 minutes to get results. In urgent situations a rapid thrombelastography test should be preferred. Although the kaolin-activated method can also be used, results must be interpreted with caution.

  5. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  6. Effects of Rebixiao Granules(热痹消颗粒剂) on Blood Uric Acid in Patients with Repeatedly Attacking Acute Gouty Arthritis

    Institute of Scientific and Technical Information of China (English)

    JI Wei; ZHU Xuan-xuan; TAN Wen-feng; LU Yan

    2005-01-01

    Objective:To observe the clinical effect of Rebixiao granule (热痹消颗粒剂, RBXG) in treating repeatedly attacking acute gouty arthritis and through experimental study on blood uric acid to explore RBXG's therapeutic mechanism. Methods: Ninety repeatedly attacking acute gouty arthritis patients were divided into the treated group (n= 60) and control group (n = 30). The treated group was treated with RBXG, and the control group was treated with Futalin tablets (diclofenac sodium). The baseline treatment including good rest, Iow purine diet, sufficient water drinking and urine alkalization, etc. was then given to both groups. Hypoxanthine 600 mg/kg and niacin 100 mg/kg was applied to hyperuricemic mice by gastrogavage to establish the animal models. Results: The clinical effective rate of the treated group was 95.0% and that of the control 90.0 %. Good therapeutic effects were won, insignificant difference (P>0.05)was shown between the two groups. However, the cure rate of the treated group was 26.7% while that of the control group was 10.0%, with significant difference (P<0.01) shown between them. The treated group had its blood uric acid lowered, which was significantly different (P<0.05) from that of the control group. The animal experiment indicated that all the three groups treated with different dosages of RBXG, as well as the Ash bark and Smilax glabra rhizome groups had their blood uric acid content reduced in the hyperuricemic mice. Conclusion: RBXG has a quicker initiation and better treatment effects than sole anti-inflammatory and analgesic agents on the treatment of repeatedly attacking acute gouty arthritis, showing no obvious toxic or adverse reactions and therefore good for long-term administration and likely to be a safe TCM preparation to control the symptoms and reduce the onsets of repeatedly attacking of acute gouty arthritis. The animal experiment shows that both the compound preparation and part of the single ingredients in the

  7. Inactivation of human immunodeficiency virus type 1 in blood samples stored as high-salt lysates.

    Science.gov (United States)

    Zolg, J W; Lanciotti, R S; Wendlinger, M; Meyer, W A

    1990-09-01

    Blood samples to be tested for the presence of parasite DNA by using specific DNA probes are routinely stored in our laboratory as high-salt lysates (HSL). To safeguard against the risk of accidental infection with etiological agents such as the human immunodeficiency virus type 1 (HIV-1) while manipulating large numbers of blood samples in preparation for DNA probing, we determined the residual infectivity of HIV-1 after exposure to HSL components. Both high-titer virus stocks or provirus-carrying cells, suspended either in tissue culture medium or freshly drawn blood, were completely inactivated upon contact with the HSL components. This was verified by the absence of any detectable HIV-1-specific antigen in the supernatants of long-term cultures and the absence of virus-specific DNA fragments after amplification by polymerase chain reaction with DNA from such cultures as target DNA. These results support the conclusion that the virus is in fact completely inactivated by contact with the HSL components, rendering blood specimens stored as HSL noninfectious in regard to HIV-1.

  8. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  9. Assessment of erythrocyte aggregation in whole blood samples by light backscattering: clinical applications

    Science.gov (United States)

    Priezzhev, Alexander V.; Firsov, Nikolai N.; Vyshlova, Marina G.; Lademann, Juergen; Richter, Heike; Kiesewetter, Holger; Mueller, Gerhard J.

    1999-05-01

    We report on the results of a collaborative effort made in the field of optical diagnostics of whole blood samples to study the ability of red blood cells to aggregate in a Couette chamber. We studied a possibility to quantitatively measure this ability as a function of the physiological state of blood donors. The aggregometer designed by the Russian coauthors of this paper and described in their earlier publications (see e.g. Proc SPIE 1884, 2100, 2678, 2982) was extensively used in the experiments performed in the Rheumatology Institute in Moscow and in the Charite Clinic in Berlin. The following parameters were measured: two characteristic times of RBC aggregation and the average spontaneous aggregation rate in the state of stasis, the average hydrodynamic strength of all aggregates and that of the largest aggregates. Different algorithms of the remission signal processing for the quantitative evaluation of the above parameters were compared. Reproducible alterations of the parameters from their normal values were obtained for blood samples from individuals suffering auto-immune disease and diabetes. Statistical data is reported proving high efficiency of the technique for the diagnostics of rheological disorders. Basing on these data the quantitative criteria of the heaviness of hemorheological state of the patients are proposed that are important for choosing specific therapies for which the patient is minimally resistant.

  10. Comparison of Different Blood Collection, Sample Matrix, and Immunoassay Methods in a Prenatal Screening Setting

    Directory of Open Access Journals (Sweden)

    Jeroen L. A. Pennings

    2014-01-01

    Full Text Available We compared how measurements of pregnancy-associated plasma protein A (PAPP-A and the free beta subunit of human chorionic gonadotropin (fβ-hCG in maternal blood are influenced by different methods for blood collection, sample matrix, and immunoassay platform. Serum and dried blood spots (DBS were obtained by venipuncture and by finger prick of 19 pregnant women. PAPP-A and fβ-hCG from serum and from DBS were measured by conventional indirect immunoassay on an AutoDELFIA platform and by antibody microarray. We compared methods based on the recoveries for both markers as well as marker levels correlations across samples. All method comparisons showed high correlations for both marker concentrations. Recovery levels of PAPP-A from DBS were 30% lower, while those of fβ-hCG from DBS were 50% higher compared to conventional venipuncture serum. The recoveries were not affected by blood collection or immunoassay method. The high correlation coefficients for both markers indicate that DBS from finger prick can be used reliably in a prenatal screening setting, as a less costly and minimally invasive alternative for venipuncture serum, with great logistical advantages. Additionally, the use of antibody arrays will allow for extending the number of first trimester screening markers on maternal and fetal health.

  11. Serial fetal blood sampling for the management of pregnancies complicated by severe rhesus (D) isoimmunization.

    Science.gov (United States)

    MacKenzie, I Z; Bowell, P J; Castle, B M; Selinger, M; Ferguson, J F

    1988-08-01

    Fifty-one pregnancies complicated by rhesus (D) isoimmunization have been managed by serial fetal blood sampling between 17 and 36 weeks gestation as an alternative to amniocentesis for delta OD453 measurements. In 36 pregnancies where the fetus was shown to be rhesus (D) positive and both measurements were made before any intrauterine fetal transfusions, the delta OD453 value gave misleading predictions on 13 of 63 occasions (21%). Fetal haematocrit estimations provided a direct assessment of the haemopoietic compensation occurring, but fetal bilirubin and albumin concentrations did not correlate directly with disease severity. It is proposed that pregnancies complicated by severe isoimmunization can be more precisely managed by serial fetal blood sampling for haematocrit estimation than amniocentesis for delta OD453 measurement thus avoiding unnecessary intervention or delayed treatment.

  12. Analysis of Short Tandem Repeat and Single Nucleotide Polymorphism Loci From Single-Source Samples Using a Custom HaloPlex Target Enrichment System Panel.

    Science.gov (United States)

    Wendt, Frank R; Zeng, Xiangpei; Churchill, Jennifer D; King, Jonathan L; Budowle, Bruce

    2016-06-01

    Short tandem repeats and single nucleotide polymorphisms (SNPs) are used to individualize biological evidence samples. Short tandem repeat alleles are characterized by size separation during capillary electrophoresis (CE). Massively parallel sequencing (MPS) offers an alternative that can overcome limitations of the CE. With MPS, libraries are prepared for each sample, entailing target enrichment and bar coding, purification, and normalization. The HaloPlex Target Enrichment System (Agilent Technologies) uses a capture-based enrichment system with restriction enzyme digestion to generate fragments containing custom-selected markers. It offers another possible workflow for typing reference samples. Its efficacy was assessed using a panel of 275 human identity SNPs, 88 short tandem repeats, and amelogenin. The data analyzed included locus typing success, depth of sequence coverage, heterozygote balance, and concordance. The results indicate that the HaloPlex Target Enrichment System provides genetic data similar to that obtained by conventional polymerase chain reaction-CE methods with the advantage of analyzing substantially more markers in 1 sequencing run. The genetic typing performance of HaloPlex is comparable to other MPS-based sample preparation systems that utilize primer-based target enrichment.

  13. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Gil, F., E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  14. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Olmedo, P; Pla, A; Hernández, A F; López-Guarnido, O; Rodrigo, L; Gil, F

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  15. Effect of Ibuprofen Dose on Platelet Aggregation and Coagulation in Blood Samples From Pigs

    Science.gov (United States)

    2015-03-01

    Samples From Pigs 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Martini W. Z., Deguzman R., Rodriguez C. M., Guerra J...from area under the curve that an oral dose can be nearly 100% absorbed,16 the estimated plasma concentration from the highest recommended dose would...20 +, respectively. Buffered blood bank saline ( Isotonic solution 0.85% w/v, Thermo Scientific, Waltham, Massachusetts) was used for volume matching

  16. Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples.

    Science.gov (United States)

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2016-07-28

    In this paper a protocol for the quick and standardized enrichment of leukocytes from small whole blood samples is described. This procedure is based on the hypotonic lysis of erythrocytes and can be applied to human samples as well as to blood of non-human origin. The small initial sample volume of about 50 to 100 µl makes this method applicable to recurrent blood sampling from small laboratory animals. Moreover, leukocyte enrichment is achieved within minutes and with low material efforts regarding chemicals and instrumentation, making this method applicable in multiple laboratory environments. Standardized purification of leukocytes is combined with a highly selective staining method to evaluate halogenating peroxidase activity of the heme peroxidases, myeloperoxidase (MPO) and eosinophil peroxidase (EPO), i.e., the formation of hypochlorous and hypobromous acid (HOCl and HOBr). While MPO is strongly expressed in neutrophils, the most abundant immune cell type in human blood as well as in monocytes, the related enzyme EPO is exclusively expressed in eosinophils. The halogenating activity of these enzymes is addressed by using the almost HOCl- and HOBr-specific dye aminophenyl fluorescein (APF) and the primary peroxidase substrate hydrogen peroxide. Upon subsequent flow cytometry analysis all peroxidase-positive cells (neutrophils, monocytes, eosinophils) are distinguishable and their halogenating peroxidase activity can be quantified. Since APF staining may be combined with the application of cell surface markers, this protocol can be extended to specifically address leukocyte sub-fractions. The method is applicable to detect HOCl and HOBr production both in human and in rodent leukocytes. Given the widely and diversely discussed immunological role of these enzymatic products in chronic inflammatory diseases, this protocol may contribute to a better understanding of the immunological relevance of leukocyte-derived heme peroxidases.

  17. Optical detection of Trypanosoma cruzi in blood samples for diagnosis purpose

    Science.gov (United States)

    Alanis, Elvio; Romero, Graciela; Alvarez, Liliana; Martinez, Carlos C.; Basombrio, Miguel A.

    2004-10-01

    An optical method for detection of Trypanosoma Cruzi (T. cruzi) parasites in blood samples of mice infected with Chagas disease is presented. The method is intended for use in human blood, for diagnosis purposes. A thin layer of blood infected by T. cruzi parasites, in small concentrations, is examined in an interferometric microscope in which the images of the vision field are taken by a CCD camera and temporarily stored in the memory of a host computer. The whole sample is scanned displacing the microscope plate by means of step motors driven by the computer. Several consecutive images of the same field are taken and digitally processed by means of image temporal differentiation in order to detect if a parasite is eventually present in the field. Each field of view is processed in the same fashion, until the full area of the sample is covered or until a parasite is detected, in which case an acoustical warning is activated and the corresponding image is displayed permitting the technician to corroborate the result visually. A discussion of the reliability of the method as well as a comparison with other well established techniques are presented.

  18. Wuchereria bancrofti in Tanzania: microfilarial periodicity and effect of blood sampling time on microfilarial intensities

    DEFF Research Database (Denmark)

    Simonsen, Poul Erik; Niemann, L.; Meyrowitsch, Dan Wolf

    1997-01-01

    pattern was observed. Mathematical analysis of the data indicated a peak at 0152 h and a periodicity index of 117.5. A periodicity equation was developed describing the average relation between mf intensity and hour of the day for the study area. Based on the observed periodicity pattern, the effect...... of blood sampling before peak time is discussed, and the importance of taking sampling time into consideration when analysing data from epidemiological studies is emphasized. A simple method is devised which can be used to adjust for the influence of time on mf intensities, in studies where accurate...

  19. Disseminated rhinovirus C8 infection with infectious virus in blood and fatal outcome in a child with repeated episodes of bronchiolitis.

    Science.gov (United States)

    Lupo, Julien; Schuffenecker, Isabelle; Morel-Baccard, Christine; Bardet, Julie; Payen, Valérie; Kaiser, Laurent; Constant, Samuel; Lobrinus, Johannes Alexander; Lin-Marq, Nathalie; Lina, Bruno; Morand, Patrice; Tapparel, Caroline

    2015-05-01

    We report a fatal case of acute lower respiratory tract disease with human rhinovirus C (HRV-C) as the unique cause in a 19-month-old girl with a history of repeated episodes of bronchiolitis. HRV-C type 8 nucleic acids were observed in respiratory, stool, and cerebrospinal fluid samples, and infectious virions were isolated from patient serum after inoculation onto reconstituted airway epithelia.

  20. The effect of sodium fluoride on the stability of cyanide in postmortem blood samples from fire victims.

    Science.gov (United States)

    McAllister, J L; Roby, R J; Levine, Barry; Purser, David

    2011-06-15

    Assigning a level of significance to cyanide concentrations found in the blood of fire victims is often hampered by the fact that cyanide is inherently unstable in cadavers and in stored blood samples. A few researchers have proposed that sodium fluoride can be used to minimize the instability of cyanide in blood samples; however, controlled studies have not been performed to support validation of this hypothesis. To test the sodium fluoride hypothesis, both treated and control blood samples from 14 autopsied fire victims were tested over a 25-30 day period. A 2% concentration of sodium fluoride was added to the blood samples at the start of testing and the samples were refrigerated between testing intervals. Cyanide concentrations in the treated and control samples were measured between 9 and 11 days post treatment and between 25 and 30 days post treatment. A statistically significant difference was not present between blood cyanide concentrations in treated and control samples between 9 and 11 days. During this time period, although there were small statistically significant increases in both treated and untreated samples the fluctuations were minor. Since the treated and control samples did not exhibit instability between 9 and 11 days, it is not surprising that the sodium fluoride appeared to have no effect. However, a statistically significant difference between blood cyanide concentrations in treated and control samples was observed between 25 and 30 days. Those samples treated with sodium fluoride showed a reduction in blood cyanide variability with virtually no overall change, over a 25-30 day period when compared to control samples, while unconditioned samples showed a significant, average increase of 35%. Based on the findings of this study, it is recommended that 2% sodium fluoride be added to blood samples obtained from fire victims to reduce cyanide instability due to bacteriological activity.

  1. The effects of repeated administration of camphor-crataegus berry extract combination on blood pressure and on attentional performance - a randomized, placebo-controlled, double-blind study.

    Science.gov (United States)

    Erfurt, L; Schandry, R; Rubenbauer, S; Braun, U

    2014-09-25

    The present study investigated the effects of repeated administration of Korodin(®), a combination of camphor and crataegus berry extract, on blood pressure and attentional functioning. This study was conducted based on a randomized, placebo-controlled, double-blind design. 54 persons participated (33 female, 21 male) with a mean age of 24.3 years. Blood pressure and body mass index were in the normal range. Participants received 20 drops of either Korodin(®) or a placebo for four times with interjacent time intervals of about 10 min. Blood pressure was measured sphygmomanometrically before and after each administration. Attentional performance was quantified by using two paper-and-pencil tests, the d2 Test of Attention and Digit Symbol Test. Greater increases in blood pressure occurred after the four Korodin(®) administrations in comparison to the four placebo administrations. The performance in two parameters of d2 Test of Attention was consistently superior after the intake of Korodin(®). The excellent tolerability and safety of Korodin(®), even after a total consumption of 80 drops, was confirmed. Copyright © 2014 Elsevier GmbH. All rights reserved.

  2. Robustness of genome-wide scanning using archived dried blood spot samples as a DNA source

    Directory of Open Access Journals (Sweden)

    Børglum Anders D

    2011-07-01

    Full Text Available Abstract Background The search to identify disease-susceptible genes requires access to biological material from numerous well-characterized subjects. Archived residual dried blood spot (DBS samples, also known as Guthrie cards, from national newborn screening programs may provide a DNA source for entire populations. Combined with clinical information from medical registries, DBS samples could provide a rich source for productive research. However, the amounts of DNA which can be extracted from these precious samples are minute and may be prohibitive for numerous genotypings. Previously, we demonstrated that DBS DNA can be whole-genome amplified and used for reliable genetic analysis on different platforms, including genome-wide scanning arrays. However, it remains unclear whether this approach is workable on a large sample scale. We examined the robustness of using DBS samples for whole-genome amplification following genome-wide scanning, using arrays from Illumina and Affymetrix. Results This study is based on 4,641 DBS samples from the Danish Newborn Screening Biobank, extracted for three separate genome-wide association studies. The amount of amplified DNA was significantly (P Conclusion Our study indicates that archived DBS samples from the Danish Newborn Screening Biobank represent a reliable resource of DNA for whole-genome amplification and subsequent genome-wide association studies. With call-rates equivalent to high quality DNA samples, our results point to new opportunities for using the neonatal biobanks available worldwide in the hunt for genetic components of disease.

  3. Rapid, Repeat-sample Monitoring of Crustal Deformations and Environmental Phenomena with the Uninhabited Aerial Vehicle Synthetic Aperture Radar

    Science.gov (United States)

    Smith, Robert C.

    2006-01-01

    The Uninhabited Aerial Vehicle Synthetic Aperture Radar (UAVSAR) is a precision repeat-pass Interferometric Synthetic Aperture Radar (InSAR) mission being developed by the Jet Propulsion Laboratory and the Dryden Flight Research Center in support of NASA s Science Mission Directorate. UAVSAR's unique ability to fly a repeatable flight path, along with an electronically steerable array, allows interferometric data to be obtained with accuracies measured in millimeters. Deploying the radar on an airborne platform will also allow for radar images to be collected and compared with images from the same area taken hours or even years later - providing for long-term trending and near real-time notification of changes and deformations. UAVSAR s data processing algorithms will provide for near-real time data reduction providing disaster planning and response teams with highly accurate data to aid in the prediction of, and response to, natural phenomena. UAVSAR data can be applied to increasing our understanding of the processes behind solid earth, cryosphere, carbon cycle and other areas of interest in earth science. Technologies developed for UAVSAR may also be applicable to a future earth-orbiting InSAR mission and possibly for missions to the Moon or Mars. The UAVSAR is expected to fly on a Gulfstream III aircraft this winter, followed by a flight test program lasting until the second half of 2007. Following radar calibration and data reduction activities, the platform will be ready for science users in the summer of 2008.

  4. Dried blood spots as a sampling technique for the quantitative determination of guanfacine in clinical studies.

    Science.gov (United States)

    Li, Yuanyuan; Henion, Jack; Abbott, Richard; Wang, Phillip

    2011-11-01

    Dried blood spot (DBS) technology was evaluated for the quantitative determination of guanfacine in human blood in clinical studies. A very sensitive DBS assay has been developed using HPLC coupled with an AB Sciex 5500 QTRAP® (Applied Biosystems/MDS Sciex, ON, Canada) MS system (LC-MS/MS) with a linear calibration range of 0.05 to 25 ng/ml. High-resolution MS using an Exactive Orbitrap® (ThermoFisher, LLC., CA, USA) was compared with the QTRAP using extracted exact mass ion current profiles for guanfacine and its stable-isotope-incorporated internal standard. The sample preparation employed liquid-liquid extraction with methyl t-butyl ether of 5 mm punched DBS card disks, followed by reversed-phase HPLC separation coupled with either MS/MS or high-resolution MS. Routine experiments were performed to establish the robustness of the DBS assay, including precision, accuracy, linearity, selectivity, sensitivity and long-term stability of up to 76 days. In addition, several factors that potentially affect quantitation were investigated, including blood volume for DBS spotting, punch size and punch location. A sensitive research assay with a LLOQ of 0.05 ng/ml was developed and subjected to several components of a method validation common to a regulated bioanalysis procedure employing DBS. This method development and partial validation study determined that spot volume, punch size or punch location do not affect assay accuracy and precision. The DBS approach was successfully applied to a clinical study (a Phase I, randomized, double-blind, placebo-controlled, crossover study to assess the effect of varying multiple oral doses of guanfacine on the pharmacokinetic, pharmacodynamic, safety, and tolerability profiles in healthy adult subjects). The pharmacokinetic profiles for 12 volunteers generated from the DBS assay and from a previously validated plasma assay were compared and were found to be comparable. DBS incurred samples collected from finger prick blood and

  5. Comparative analysis of RNA-Seq data from brain and blood samples of Parkinson's disease.

    Science.gov (United States)

    Chatterjee, Paulami; Roy, Debjani

    2017-03-11

    Parkinson's disease (PD) is the second most common neurodegenerative disorders throughout the world. In order to search for PD biomarkers, we performed a system-level study of RNA-Seq data from PD brain and blood samples. Differentially expressed miRs of RNA-Seq data were subjected to generate the Co-expression networks. Three highly co-expressed clusters were identified based on their correlation coefficient values and fold change ratio. SM2miR drugs of the miRs contained in the three highly co-expressed clusters were identified, and drugs common among these clusters were selected. Co-expressed miRs not previously known to be associated with PD were identified from both the samples. Functional enrichment analyses of these miR targets were done, and the pathways common and unique to both the samples were identified. Thus, our study presents a comparative analysis of miRs, their associated pathways, and drugs from brain and blood samples of PD that may help in system level understanding of this disease. miRs identified from our study may serve as biomarkers for PD.

  6. Detection of Streptococcus mutans Genomic DNA in Human DNA Samples Extracted from Saliva and Blood

    Science.gov (United States)

    Vieira, Alexandre R.; Deeley, Kathleen B.; Callahan, Nicholas F.; Noel, Jacqueline B.; Anjomshoaa, Ida; Carricato, Wendy M.; Schulhof, Louise P.; DeSensi, Rebecca S.; Gandhi, Pooja; Resick, Judith M.; Brandon, Carla A.; Rozhon, Christopher; Patir, Asli; Yildirim, Mine; Poletta, Fernando A.; Mereb, Juan C.; Letra, Ariadne; Menezes, Renato; Wendell, Steven; Lopez-Camelo, Jorge S.; Castilla, Eduardo E.; Orioli, Iêda M.; Seymen, Figen; Weyant, Robert J.; Crout, Richard; McNeil, Daniel W.; Modesto, Adriana; Marazita, Mary L.

    2011-01-01

    Caries is a multifactorial disease, and studies aiming to unravel the factors modulating its etiology must consider all known predisposing factors. One major factor is bacterial colonization, and Streptococcus mutans is the main microorganism associated with the initiation of the disease. In our studies, we have access to DNA samples extracted from human saliva and blood. In this report, we tested a real-time PCR assay developed to detect copies of genomic DNA from Streptococcus mutans in 1,424 DNA samples from humans. Our results suggest that we can determine the presence of genomic DNA copies of Streptococcus mutans in both DNA samples from caries-free and caries-affected individuals. However, we were not able to detect the presence of genomic DNA copies of Streptococcus mutans in any DNA samples extracted from peripheral blood, which suggests the assay may not be sensitive enough for this goal. Values of the threshold cycle of the real-time PCR reaction correlate with higher levels of caries experience in children, but this correlation could not be detected for adults. PMID:21731912

  7. A Simple, Inexpensive and Safe Method for DNA Extraction of Frigid and Clotted Blood Samples

    Directory of Open Access Journals (Sweden)

    Nasrin Mohammadi

    2015-07-01

    Full Text Available Background: Extraction of blood genomicDNAis one of the main approaches for clinical and molecular biology studies. Although several methods have been developed for extraction of blood genomic DNA, most of these methods consume long time and use expensive chemicals such as proteinase K and toxic organic solvent such as phenol and chloroform. The objective of this study was to developed easy and safe method forDNAextraction from clotted and frozen whole blood. This method has many advantages: time reducing, using inexpensive materials, without phenol and chloroform, achieving of high molecular weight and good quality genomicDNA.Materials and Methods: DNA extraction was performed by two methods (new and phenol-chloroform method. Then quantity and quality parameters were evaluated by 1% agarose gel electrophoresis, Nano drop analysis and efficiency of Polymerase Chain Reaction (PCR.Results: Extracted DNA from 500μL of blood samples were 457.7ng/μl and 212ng/μL and their purity (OD260/OD280 were 1.8 and 1.81 for new recommended and phenol–chloroform methods respectively. The PCR results indicated that D16S539 and CSF1PO loci were amplified.Conclusion: These results shown that this method is simple, fast, safe and most economical.

  8. Sensitivity of PCR assays for murine gammaretroviruses and mouse contamination in human blood samples.

    Directory of Open Access Journals (Sweden)

    Li Ling Lee

    Full Text Available Gammaretroviruses related to murine leukemia virus (MLV have variously been reported to be present or absent in blood from chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME patients and healthy controls. Using subjects from New York State, we have investigated by PCR methods whether MLV-related sequences can be identified in nucleic acids isolated from whole blood or from peripheral blood mononuclear cells (PBMCs or following PBMC culture. We have also passaged the prostate cancer cell line LNCaP following incubation with plasma from patients and controls and assayed nucleic acids for viral sequences. We have used 15 sets of primers that can effectively amplify conserved regions of murine endogenous and exogenous retrovirus sequences. We demonstrate that our PCR assays for MLV-related gag sequences and for mouse DNA contamination are extremely sensitive. While we have identified MLV-like gag sequences following PCR on human DNA preparations, we are unable to conclude that these sequences originated in the blood samples.

  9. Assessment of malathion and its effects on leukocytes in human blood samples

    Science.gov (United States)

    Sharma, Amit Kumar; Tiwari, Udita; Gaur, Mulayam Singh; Tiwari, Rajeev Kumar

    2016-01-01

    Abstract In the present paper, we report a reproducible, cost effective, fast response method for detection of malathion and its effects on leukocytes in different human blood groups. Spectroscopic methods (UV-Vis spectrometry) and Fourier transform infrared coupled with solid phase extraction were applied for analyzing malathion content in human blood plasma. The spiking levels of malathion in the range of 0.1-1.7 µg/mL were extracted from blood plasma samples using SPE. The present active functional groups (C = O; P-O-C; -OH; P = S) were also characterized. The recovery rate of malathion was 80%±4.5%. The calculated correlation coefficient was 0.9799, indicating the linearity of the results. The limit of detection (LOD) and limit of quantification (LOQ) were (0.1-1.7) µg/mL and (0.3-1.5) µg/mL, respectively. Malathion <1.0 µg/mL showed no significant change while higher levels of malathion exposure (1.5 µg/mL and 3.0 µg/mL) reduced the number of white blood cells. In conclusion, the spectroscopic results may be useful to understand the mechanism of other pesticides such as methyl parathion and parathion.

  10. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    Directory of Open Access Journals (Sweden)

    Ironside James W

    2007-08-01

    Full Text Available Abstract Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc, although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS, which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems.

  11. Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis

    DEFF Research Database (Denmark)

    Andersen, David Wederkinck; Rasmussen, Brian; Linnet, Kristian

    2012-01-01

    A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography...

  12. Evaluation of Chromosomal Disorders in Tissue and Blood Samples in Patients with Oral Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    A. Parvaneroo

    2004-12-01

    Full Text Available Statement of Problem: Many studies have indicated that genetic disturbances are common findings in patients with Oral Squamous Cell Carcinoma (OSCC. Identification of these changes can be helpful in diagnostic procedures of these tumors.Purpose: The aim of this study was to appraise the chromosomal disorders in blood and tissue patients with OSCC.Methods and Materials: In this descriptive study, the study group consisted of all OSCC patients who were referred to the Faculty of Dentistry, Tehran University of Medical Sciences, Maxillofacial Surgery Clinic of Shariati Hospital, and Amir Aalam Hospital fromSeptember 2000 to November 2002. In order to study chromosomal disorders in the peripheral blood lymphocytes, 5 mL of blood was obtained from each patient In patients with the large lesion, a piece of involved tissue were obtained and cultured for 24 hours.This led to 29 blood samples and 16 tissue specimens and any relation between OSCC and age, sex, smoking and alcohol use were evaluated.Results: In this study, OSCC was more common in males than in females (3 to 5. 31% of our patients were smokers, and one had a history of alcoholic consumption. There was an increase in incidence of OSCC with age. In this study, all patients had numerical(aneuploidy, polyploidy and structural chromosomal disorders (double minute, fragment,breakage and dicentric. There was significant difference between blood and tissue chromosomal disorders (aneuploidy, polyploidy,breakage in OSCC patients.Conclusion: It can be concluded that chromosomes in patients with OSCC might show some genetic aberration and evaluation of involved tissue might be better way for determining this disorders.

  13. Chromatographic resolution, characterisation and quantification of VX enantiomers in hemolysed swine blood samples.

    Science.gov (United States)

    Reiter, Georg; Mikler, John; Hill, Ira; Weatherby, Kendal; Thiermann, Horst; Worek, Franz

    2008-09-15

    The present study was initiated to develop a sensitive and highly selective method for the analysis of the enantiomers of the nerve agent VX (O-ethyl S-[2(diisopropylamino)ethyl] methylphosphonothioate) in blood samples for toxicokinetic and therapeutic research. To achieve this goal, analytical and semi-preparative enantioseparation of VX were carried out with gas and liquid chromatography. The GC chiral stationary phase was HYDRODEX-beta-TBDAc (beta cyclodextrin), on which VX was baseline-resolved. On the chiral HPLC phase CHIRALCEL OD-H the enantiomers of VX were isolated with enantiomeric excess >99.99%. They were characterised by specific optical rotation (+/-25.8 deg ml dm(-1)g(-1) at 20 degrees C and 589 nm) and by determination of cholinesterase inhibition rate constants. For the quantitative chiral detection of VX the enantioresolution was realized on the HPLC chiral phase CHIRAL AGP. A specific procedure was developed to isolate VX from swine blood samples thereby stabilising its enantiomers. The limit of detection was 200 fg per enantiomer on column. The absolute recovery of the overall sample preparation procedure was 75%. After an intravenous and percutaneous administration of a supralethal dose of VX in anesthetised swine (+)-VX and (-)-VX could be quantified up to 720 min.

  14. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.

  15. Is liquid heparin comparable to dry balanced heparin for blood gas sampling in intensive care unit?

    Directory of Open Access Journals (Sweden)

    Viswas Chhapola

    2014-01-01

    Full Text Available Introduction: Blood gas (BG analysis is required for management of critically ill patients in emergency and intensive care units. BG parameters can be affected by the type of heparin formulations used-liquid heparin (LH or dry balanced heparin (DBH. This study was conducted to determine whether blood gas, electrolyte, and metabolite estimations performed by using DBH and LH are comparable. Materials and Methods: A prospective study was conducted at pediatric intensive care unit (PICU of a tertiary care hospital. Paired venous samples were collected from 35 consecutive children in commercially prepared DBH syringes and custom-prepared LH syringes. Samples were immediately analyzed by blood gas analyzer and compared for pH, pCO 2 , pO 2 , HCO 3 - , Na + , K + , Cl - , and lactate. Paired comparisons were done and agreement was assessed by Bland-Altman difference plots. The 95% limits of absolute agreement (LOA were compared with the specifications for total allowable error (TEa. Results: The P values were significant for all measured parameters, with the exception of pCO 2 and K +. Bland-Altman difference plots showed wide LOA for pCO 2 , pO 2 , HCO3 - , Na + , K + , and Cl - when compared against TEa. For pCO 2 , HCO3 - , Na + , K + , and Cl - , 40%, 23%, 77%, 34%, and 54% of samples were outside the TEa limits, respectively, with LH. Conclusion: Our study showed that there is poor agreement between LH and DBH for the BG parameters pCO2, pO2, HCO3 - , K + , Na + , and Cl - and, thus, are not comparable. But for pH and lactate, LH and DBH can be used interchangeably.

  16. Description of a new non-injectable connector to reduce the complications of arterial blood sampling.

    Science.gov (United States)

    Mariyaselvam, M Z; Heij, R E; Laba, D; Richardson, J A; Hodges, E J; Maduakor, C A; Carter, J J; Young, P J

    2015-01-01

    Arterial cannulation is associated with complications including bacterial contamination, accidental intra-arterial injection and blood spillage. We performed a series of audits and experiments to gauge the potential for these, as well as assess the possible contribution of a new device, the Needle-Free Arterial Non-Injectable Connector (NIC), in reducing these risks. The NIC comprises a needle-free connector that prevents blood spillage and a one-way valve allowing aspiration only; once screwed onto the side port of a three-way tap, the device can only be removed with difficulty. We performed a clinical audit of arterial monitoring systems in our intensive care unit, which showed an incidence of bacterial colonisation of five in 86 (6%) three-way tap ports. We constructed a manikin simulation experiment of the management of acute bradycardia, in which trainee doctors were required to inject atropine intravenously. Ten of 15 (66%) doctors injected the drug into the three-way tap of the arterial monitoring system rather than into the intravenous cannula or the central venous catheter. In a laboratory study, we replicated the arterial blood sampling and flushing sequence from a three-way tap, with the syringes attached either directly to the three-way tap port or to a NIC attached to the port. The first (discard) syringe attached to the three-way tap was contaminated with bacteria. Bacterial growth was found in 17 of 20 (85%) downstream flushed samples (corresponding to the patient's circulation) when the three-way tap was accessed directly, compared to none of 20 accessed via the NIC (p contaminating sampling lines. As its design also prevents accidental intra-arterial injection, we suggest that it can reduce complications of arterial monitoring. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  17. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Directory of Open Access Journals (Sweden)

    Fredric M. Hustey

    2016-09-01

    Full Text Available Introduction: Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods: The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest® for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results: During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]. Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99] or mild (10.3% vs 9.8% [p=0.88] hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%. Conclusion: We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material. Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  18. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Science.gov (United States)

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  19. Acetaminophen and Meloxicam Inhibit Platelet Aggregation and Coagulation in Blood Samples from Humans

    Science.gov (United States)

    2014-01-01

    used for over 50 years to relieve pains associated with arthritis , headache, mus- cular aches, and to reduce fever in adults and children. As in most...participant was sampled once with a total of 100-ml blood volume. Exclusion criteria included pregnancy , on- going therapeutic anticoagulation, and use... rheumatic disease. Clin Ther 2000; 22:400–410; S0149-2918(00)89009-8 [pii] 10.1016/ S0149-2918(00)89009-8. 5 Hawkey C, Kahan A, Steinbruck K, Alegre C

  20. Whole Genome Expression in Peripheral-Blood Samples of Workers Professionally Exposed to Polycyclic Aromatic Hydrocarbons

    OpenAIRE

    Wu, Ming-Tsang; Lee, Tzu-Chi; Su, Hung-Ju; Huang, Jie-Len; Peng, Chiung-Yu; Wang, Weihsin; Chou, Ting-Yu; Lin, Ming-Yen; Lin, Wen-Yi; Huang, Chia-Tsuan; Pan, Chih-Hong; Ho, Chi-Kung

    2011-01-01

    This study aims to examine global gene expression profiles before and after the work-shift among coke-oven workers (COW). COW work six consecutive days and then take two days off. Two blood and urine samples in each worker were collected before starting to work after two-days off and end-of-shift in the sixth-day work in 2009. Altered gene expressions (ratio of gene expression levels between end-of-shift and pre-shift work) were performed by Human OneArray expression system which probes ∼30,0...

  1. Weekday variation in triglyceride concentrations in 1.8 million blood samples

    DEFF Research Database (Denmark)

    Jaskolowski, Jörn; Ritz, Christian; Sjödin, Anders Mikael

    2017-01-01

    BACKGROUND: Triglyceride (TG) concentration is used as a marker of cardio-metabolic risk. However, diurnal and possibly weekday variation exists in TG concentrations. OBJECTIVE: To investigate weekday variation in TG concentrations among 1.8 million blood samples drawn between 2008 and 2015 from...... variations in TG concentrations were recorded for out-patients between the age of 9 to 26 years, with up to 20% higher values on Mondays compared to Fridays (all PTriglyceride concentrations were highest after the weekend and gradually declined during the week. We suggest that unhealthy...

  2. Evaluation of blood microsampling techniques and sampling sites for the analysis of drugs by HPLC-MS.

    Science.gov (United States)

    Smith, Christopher; Sykes, Angela; Robinson, Sally; Thomas, Elizabeth

    2011-01-01

    the potential for whole blood sampling (20 µl) in toxicokinetic studies to reduce the sample volume was investigated. Blood microsamples were collected in three ways, either as a dried blood spot (DBS), a blood sample collected in a micropipette placed in a plastic tube and mixed with water or as plasma in the normal manner. blood samples on the DBS and the whole blood microtube (WBMT) were compared along with DBS and plasma to determine the toxicokinetic data equivalency. The DBS and WBMT comparison was shown to be equivalent, as demonstrated on a correlation plot with an R(2) value of 0.97 for an x = y plot. The plasma comparison with DBS also gave a good correlation. A correction factor (x(2)) was applied to the blood data to allow for the distribution of the compound between plasma and bloods, and therefore, a direct comparison could be made. The correlation plot derived from the sample data gave an R(2) value 0.98 (x = y plot), indicating dataset equivalency. Sampling sites were evaluated in a dog study. Blood was collected from the peripheral region, in this case the ear, and a venous region of the dog; and spotted onto DBS cards. Comparison of the mean area under the curve data for the sampling sites showed equivalent data: 5095 and 5175 ng.h/ml for the 25 mg/kg dose and 16695 ng.h/ml and 16000 ng.h/ml for the 50 mg/kg dose for the ear and the venous samples, respectively. the DBS cards were shown to be an equivalent microsampling process when compared with WBMT and conventional plasma analysis. With the added benefits of sample storage, shipment and ease of use for DBS, this technology could change the way samples are taken and then analyzed in bioanalysis in the future.

  3. Concentrations of persistent organic pollutants (POPs) in human blood samples from Mexico City, Mexico.

    Science.gov (United States)

    Orta-García, Sandra; Pérez-Vázquez, Francisco; González-Vega, Carolina; Varela-Silva, José Antonio; Hernández-González, Lidia; Pérez-Maldonado, Iván

    2014-02-15

    Studies in Mexico have demonstrated exposure to persistent organic pollutants (POPs) in people living in different sites through the country. However, studies evaluating exposure to POPs in people living in Mexico City (one of most contaminated places in the world) are scarce. Therefore, the aim of this study was to assess the levels of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), dichlorodiphenyltrichloroethane (DDT) and its metabolite dichlorodiphenyldichloroethylene (DDE) in the blood as exposure biomarkers in people living in Mexico City. A total of 123 participants (blood donors aged 20-60 years) were recruited during 2010 in Mexico City. Quantitative analyses of blood samples were performed using gas chromatography coupled with mass spectrometry. Levels of the assessed compounds ranged from non-detectable (

  4. Development of a simple device for processing whole-blood samples into measured aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W F; Walker, W A

    1986-09-01

    A capillary processor and aliquoter has been designed and fabricated that is capable of accepting aliquots of whole blood and automatically processing them into discrete aliquots of plasma. The device consists of two disks, each of which contains 16 individual capillaries and a processing rotor. One disk accepts larger capillaries that hold approximately 100 microL of whole blood each. The second disk accepts 2.54-cm-long precision capillaries of various internal diameters, which provide exact sample volumes from 1 to 10 microL. The processing rotor contains 16 individual compartments and chambers to accept both disks. Applying centrifugal force transfers the aliquots of whole blood into their respective compartments, where they are separated into cellular and plasma fractions. As the rotor speed is slowly decreased, an aliquot of plasma is withdrawn by capillary action into each measuring capillary. The disk containing the 16 measured aliquots of plasma is then removed and placed into a modified rotor for conventional centrifugal analysis. This device can entrain and deliver microliter volumes of liquids with precision and accuracy (1-2%) near that of mechanical pipettes. Assays of the separated plasma aliquots also have acceptable precision (e.g., CVs approximately 3% for measurements of serum enzymes).

  5. Dried blood spot sampling for hepatitis B virus serology and molecular testing.

    Directory of Open Access Journals (Sweden)

    Sofiane Mohamed

    Full Text Available BACKGROUND AIMS: Dried blood spots (DBS on filter paper have been successfully used to diagnose and monitor several infectious diseases. The aim was to investigate the performance of DBS in hepatitis B virus (HBV diagnosis using commercial tests in comparison to standard methods. METHODS: Paired DBS and plasma samples were collected from 200 patients: 100 patients with HBsAg negative status and 100 patients with HBsAg positive status. In the latter patient, HBeAg reactivity was tested. Ten samples of anti-HBs were collected from people vaccinated against HBV. We also studied 50 patients with positive HBV DNA viral load in plasma and 10 HBV DNA negative patients. HBV genotypes and gene polymerase mutations were determined in 10 randomly selected HBV-infected patients. The DBS sample consisted of 50 µL of whole blood, i.e. a 12-mm paper card. RESULTS: The sensitivity thresholds of HBsAg and anti-HBs antibody were 0.30 ± 0.08 IU/mL and 18.11 ± 6.05 IU/mL, respectively, for DBS with 98% sensitivity and 100% specificity. Sensitivity was 98% and specificity 100% for the detection of HBV DNA on a blotter, considering an HBV DNA threshold of 914.1 ± 157.8 IU/ml. Ten patients had an HBeAg positive status in plasma, all were detected positive using DBS. HBV genotyping and mutation detection were successfully performed on DBS, with full concordance between the 10 paired DBS and plasma samples. CONCLUSION: This study shows DBS is a reliable alternative to plasma specimens for quantifying and detecting HBsAg, anti-HBs, HBeAg and genotyping. DBS may increase the opportunities for HBV testing and treatment follow-up in hard-to-reach individuals.

  6. Vitreous humor as an alternative sample to blood for the supercritical fluid extraction of morphine and 6-monoacetylmorphine.

    Science.gov (United States)

    Scott, K S; Oliver, J S

    1999-01-01

    The use of vitreous humor as an alternative sample to blood was investigated for the detection of heroin abuse by quantifying levels of morphine and 6-monoacetylmorphine (6-MAM) in post-mortem samples. The levels achieved in each of the two toxicological specimens were compared on a case-to-case basis to determine if a correlation existed. A total of 20 positive morphine cases were examined. In general, the levels of morphine in blood were higher than in the corresponding vitreous humor samples, with some correlation existing. 6-MAM was found in 15 blood samples and 17 vitreous humor samples. Although no correlation was found between the levels of 6-MAM in blood and vitreous humor, the latter may still be used for verification of heroin abuse.

  7. Characterization of a Hemoglobin Adduct from Ethyl Vinyl Ketone Detected in Human Blood Samples.

    Science.gov (United States)

    Carlsson, Henrik; Motwani, Hitesh V; Osterman Golkar, Siv; Törnqvist, Margareta

    2015-11-16

    Electrophiles have the ability to form adducts to nucleophilic sites in proteins and DNA. Internal exposure to such compounds thus constitutes a risk for toxic effects. Screening of adducts using mass spectrometric methods by adductomic approaches offers possibilities to detect unknown electrophiles present in tissues. Previously, we employed untargeted adductomics to detect 19 unknown adducts to N-terminal valine in hemoglobin (Hb) in human blood. This article describes the characterization of one of these adducts, which was identified as the adduct from ethyl vinyl ketone (EVK). The mean adduct level was 40 ± 12 pmol/g Hb in 12 human blood samples; adduct levels from acrylamide (AA) and methyl vinyl ketone (MVK) were quantified for comparison. Using l-valine p-nitroanilide (Val-pNA), introduced as a model of the N-terminal valine, the rate of formation of the EVK adduct was studied, and the rate constant determined to 200 M(-1)h(-1) at 37 °C. In blood, the reaction rate was too fast to be feasibly measured, EVK showing a half-life adduct was found to be unstable, with a half-life of 7.6 h. From the mean adduct level measured in human blood, a daily dose (area under the concentration-time-curve, AUC) of 7 nMh EVK was estimated. The AUC of AA from intake via food is about 20 times higher. EVK is naturally present in a wide range of foods and is also used as a food additive. Most probably, naturally formed EVK is a major source to observed adducts. Evaluation of available toxicological data and information on occurrence of EVK indicate that further studies of EVK are motivated. This study illustrates a quantitative strategy in the initial evaluation of the significance of an adduct detected through adduct screening.

  8. Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples

    NARCIS (Netherlands)

    Kip, Anke E; Kiers, K C; Rosing, H; Schellens, J H M; Beijnen, J H; Dorlo, T P C

    2017-01-01

    Miltefosine is an oral agent against the neglected tropical disease leishmaniasis, which is mostly endemic in resource-poor areas. Dried blood spot (DBS) sampling is an attractive alternative to plasma sampling for pharmacokinetic studies in these remote areas, but introduces additional variability

  9. A comparative evaluation of four DNA extraction protocols from whole blood sample.

    Science.gov (United States)

    Ghaheri, M; Kahrizi, D; Yari, K; Babaie, A; Suthar, R S; Kazemi, E

    2016-03-31

    All organisms have Deoxyribonucleic acid (DNA) within their cells. DNA is a complex molecule that contains all of the information necessary to build and maintain an organism. DNA extraction is one of the most basic and essential techniques in the study of DNA that allow huge advances in molecular biology, biotechnology and bioinformatics laboratories. Whole blood samples are one of the main sources used to obtain DNA and there are many different protocols available in this issue. In current research, compared four DNA extraction protocols from blood samples; include modified phenol-chloroform protocol, two salting-out and enzyme free method and from commercial kit. The extracted DNAs by these protocols were analyzed according to their time demands, quality and quantity, toxicity and functionality in PCR method. Also the quality and quantity of the extracted DNA were surveyed by gel electrophoresis and Nanodrop spectrophotometry methods. It was observed that there are not significantly differences between these methods about DNA Purity (A260/A280), but the DNA yield (ng DNA/μl) of phenol/chloroform method was higher than other methods. In addition, phenol/chloroform was the most toxic method and it takes more time than other methods. Roche diagnostics GmbH kit was the most expensive among the four methods but the least extraction time was required and it was the safest method.

  10. Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.

    Science.gov (United States)

    Lippi, Giuseppe; Avanzini, Paola; Musa, Roberta; Sandei, Franca; Aloe, Rosalia; Cervellin, Gianfranco

    2013-01-01

    In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.

  11. A STUDY OF METALLO-BETA-LACTAMASE PRODUCING PSEUDOMONAS AERUGINOSA IN BLOOD SAMPLES OF BURNED PATIENTS

    Directory of Open Access Journals (Sweden)

    Piyali

    2014-11-01

    Full Text Available : BACKGROUND: Septicaemia is a life threatening complication of severely burned patients. Among many organisms invading blood stream Pseudomonas aeruginosa is a well-known for its powerful antibiotic resistance mechanisms which increasingly limit the choices for treatment. Among many such resistance mechanisms it is the metallo-beta-lactamase (MBL which confers resistance to Carbapenem group of antibiotics, one of the final resorts to fight them. The present study was undertaken to detect MBL producing P. aeruginosa using phenotypic method from blood samples of burned patients as well as to know their drug sensitivity pattern. MATERIALS AND METHODS: For this purpose 67 Pseudomonas aeruginosa isolates from blood samples of admitted burned patients were subjected to susceptibility testing to antipseudomonal drugs by disc diffusion test and those found to be Carbapenem resistant were subjected to Imipenem - EDTA combined disk synergy test for MBL detection. RESULT: Out of 67 isolates of P.aeruginosa, 19 (28.4% were found to be Carbapenem resistant and 11 (16.4% were MBL producers. A particularly important feature was that the MBL producers were highly resistant to the antibiotics tested than the non-producers. However all of them were susceptible to Colistin and Polymixin B. CONCLUSION: This study has made us to think that a constant vigil and careful selection of antibiotics are necessary to keep prevalence of MBL producing P.aeruginosa in check. The accurate identification and reporting of MBL producing P. aeruginosa will aid infection control practitioners in preventing the spread of these multidrug-resistant isolates

  12. Analysis of intraosseous blood samples using an EPOC point of care analyzer during resuscitation.

    Science.gov (United States)

    Tallman, Crystal Ives; Darracq, Michael; Young, Megann

    2017-03-01

    In the early phases of resuscitation in a critically ill patient, especially those in cardiac arrest, intravenous (IV) access can be difficult to obtain. Intraosseous (IO) access is often used in these critical situations to allow medication administration. When no IV access is available, it is difficult to obtain blood for point of care analysis, yet this information can be crucial in directing the resuscitation. We hypothesized that IO samples may be used with a point of care device to obtain useful information when seconds really do matter. Patients presenting to the emergency department requiring resuscitation and IO placement were prospectively enrolled in a convenience sample. 17 patients were enrolled. IO and IV samples obtained within five minutes of one another were analyzed using separate EPOC® point of care analyzers. Analytes were compared using Bland Altman Plots and intraclass correlation coefficients. In this analysis of convenience sampled critically ill patients, the EPOC® point of care analyzer provided results from IO samples. IO and IV samples were most comparable for pH, bicarbonate, sodium and base excess, and potentially for lactic acid; single outliers for bicarbonate, sodium and base excess were observed. Intraclass correlation coefficients were excellent for sodium and reasonable for pH, pO2, bicarbonate, and glucose. Correlations for other variables measured by the EPOC® analyzer were not as robust. IO samples can be used with a bedside point of care analyzer to rapidly obtain certain laboratory information during resuscitations when IV access is difficult. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  14. Whole blood flow cytometry measurements of in vivo platelet activation in critically-Ill patients are influenced by variability in blood sampling techniques.

    Science.gov (United States)

    Rondina, Matthew T; Grissom, Colin K; Men, Shaohua; Harris, Estelle S; Schwertz, Hansjorg; Zimmerman, Guy A; Weyrich, Andrew S

    2012-06-01

    Flow cytometry is often used to measure in vivo platelet activation in critically-ill patients. Variability in blood sampling techniques, which may confound these measurements, remains poorly characterized. Platelet activation was measured by flow cytometry performed on arterial and venous blood from 116 critically-ill patients. We determined how variability in vascular sampling site, processing times, and platelet counts influenced levels of platelet-monocyte aggregates (PMA), PAC-1 binding (for glycoprotein (GP) IIbIIIa), and P-selectin (P-SEL) expression. Levels of PMA, but not PAC-1 binding or P-SEL expression, were significantly affected by variability in vascular sampling site. Average PMA levels were approximately 60% higher in whole blood drawn from an arterial vessel compared to venous blood (16.2±1.8% vs. 10.7±1.2%, psampling site, processing times, and platelet counts influence levels of PMA, but not PAC-1 binding or P-SEL expression. These data demonstrate the need for rigorous adherence to blood sampling protocols, particularly when levels of PMA, which are most sensitive to variations in blood collection, are measured for detection of in vivo platelet activation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Levels of carnitine and acylcarnitines in reconstituted red blood cell samples washed with different concentrations of saline solutions

    OpenAIRE

    José Henry Osorio; Morteza Pourfarzam

    2011-01-01

    Objective: To evaluate the percentage of carnitine and acylcarnitines remaining in red blood cells after washing them with different concentrations of saline solution. Materials and methods: Human blood samples were centrifuged and the blood cells were washed with different saline solutions. The final pellet was resuspended in PBS for card preparation and tandem mass spectrometry analysis. Results: It was found that carnitine, as well as short-chain, medium-chain, and long-chain acylca...

  17. Comparison of S. stercoralis serology performed on dried blood spots and on conventional serum samples.

    Directory of Open Access Journals (Sweden)

    Fabio Formenti

    2016-11-01

    Full Text Available Background. Dried blood spots (DBS are used for epidemiological surveys on infectious diseases in settings with limited resources. In fact, DBS can help to overcome logistic difficulties for the collection, transport and storage of biological specimens. Objective. To evaluate the accuracy of S. stercoralis serology performed on DBS. Methods. A survey was proposed to children attending a school in the village of Borbon, Ecuador, and to their parents/guardians. Each participant gave consent to the collection of both serum and DBS specimens. DBS absorbed on filter papers were analyzed with a commercially-available ELISA test for Strongyloides stercoralis antibodies, in parallel to the standard serology. The agreement between the two methods was assessed through the Cohen’s kappa coefficient. Results. The study sample was composed by 174 children and 61 adults, for a total of 235 serum and 235 DBS samples. The serology was positive in 31/235 (13% serum samples, and in 27/235 (11% DBS: 4 samples resulted discordant (positive at standard serology. Cohen’s kappa resulted 0.921 (95% CI 0.845 - 0.998, indicating a high rate of concordance. Conclusion. DBS are suitable for in field-surveys requiring serological testing for S. stercoralis.

  18. Comparison of S. stercoralis Serology Performed on Dried Blood Spots and on Conventional Serum Samples

    Science.gov (United States)

    Formenti, Fabio; Buonfrate, Dora; Prandi, Rosanna; Marquez, Monica; Caicedo, Cintia; Rizzi, Eleonora; Guevara, Angel G.; Vicuña, Yosselin; Huerlo, Francisco R.; Perandin, Francesca; Bisoffi, Zeno; Anselmi, Mariella

    2016-01-01

    Background: Dried blood spots (DBS) are used for epidemiological surveys on infectious diseases in settings where limited resources are available. In fact, DBS can help to overcome logistic difficulties for the collection, transport and storage of biological specimens. Objective: To evaluate the accuracy of Strongyloides stercoralis serology performed on DBS. Methods: A survey was proposed to children attending a school in the village of Borbon, Ecuador, and to their parents/guardians. Each participant gave consent to the collection of both serum and DBS specimens. DBS absorbed on filter papers were analyzed with a commercially available ELISA test for S. stercoralis antibodies, as well as with standard serology. The agreement between the two methods was assessed through the Cohen’s kappa coefficient. Results: The study sample was composed of 174 children and 61 adults, for a total of 235 serum and 235 DBS samples. The serology was positive in 31/235 (13%) serum samples, and in 27/235 (11%) DBS: 4 samples resulted discordant (positive at standard serology). Cohen’s kappa coefficient was 0.921 (95% CI 0.845 – 0.998), indicating a high rate of concordance. Conclusion: DBS are suitable for in field-surveys requiring serological testing for S. stercoralis. PMID:27877170

  19. Levels of carnitine and acylcarnitines in reconstituted red blood cell samples washed with different concentrations of saline solutions

    Directory of Open Access Journals (Sweden)

    José Henry Osorio

    2011-01-01

    Full Text Available Objective: To evaluate the percentage of carnitine and acylcarnitines remaining in red blood cells after washing them with different concentrations of saline solution. Materials and methods: Human blood samples were centrifuged and the blood cells were washed with different saline solutions. The final pellet was resuspended in PBS for card preparation and tandem mass spectrometry analysis. Results: It was found that carnitine, as well as short-chain, medium-chain, and long-chain acylcarnitines remain in red blood cells at average percentages of 19.3; 34; 34; and 32%, respectively. Significant differences were found for carnitine and acylcarnitine levels in blood washed with an isotonic solution compared to their levels using several hypotonic solutions (p<0.05. Conclusion: Because carnitine and acylcarnitines remained associated with the blood cells, we recommend using whole blood to measure these metabolites.

  20. Levels of carnitine and acylcarnitines in reconstituted red blood cell samples washed with different concentrations of saline solutions

    Directory of Open Access Journals (Sweden)

    José Henry Osorio

    2010-12-01

    Full Text Available Objective: To evaluate the percentage of carnitine and acylcarnitines remaining in red blood cells after washing them with different concentrations of saline solution.Materials and methods: Human blood samples were centrifuged and the blood cells were washed with different saline solutions. The final pellet was resuspended in PBS for card preparation and tandem mass spectrometry analysis.Results: It was found that carnitine, as well as short-chain, medium-chain, and long-chain acylcarnitines remain in red blood cells at average percentages of 19.3; 34; 34; and 32%, respectively. Significant differences were found for carnitine and acylcarnitine levels in blood washed with an isotonic solution compared to their levels using several hypotonic solutions (p<0.05.Conclusion: Because carnitine and acylcarnitines remained associated with the blood cells, we recommend using whole blood to measure these metabolites.

  1. Use of dried blood samples for monitoring hepatitis B virus infection

    Directory of Open Access Journals (Sweden)

    Muñoz Onofre

    2009-09-01

    Full Text Available Abstract Background Hepatitis B virus (HBV infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS have been successfully used to diagnose and monitor several infectious diseases. In Mexico there is an urgent need for an affordable and easy sampling method for viral load (VL testing and monitoring of chronic HBV infection. The purpose of this work was to validate the utility of DBS samples for monitoring HBV infection in patients from Mexico City. Methods Matched samples of plasma and DBS on filter paper from 47 HBV infected patients from the Instituto Mexicano del Seguro Social (IMSS, were included. To evaluate the DNA stability and purity from DBS stored at different temperature conditions, samples from ten patients were stored at 4 degree, 25 degree, and 37 degree C for 7 days. After DBS elution and DNA extraction, the purity of these samples was determined measuring the O.D. rate 260/280. The DBS utility for molecular studies was assessed with PCR assays to amplify a 322 bp fragment from the "a" determinant region of the HBV "S" gene. The VL from all samples was determined to evaluate the correlation between plasma and DBS matched samples. Results The quality of the DNA from DBS specimen is not adversely affected by storage at 4 degree, 25 degree and 37 degree C for up 7 days. Statistical ANOVA analyses did not show any significant difference. The same amplification efficiency was observed between DNA templates from samples stored at different temperatures. The Pearson correlation between the VL from DBS and plasma matched samples was 0.93 (p = 0.01. The SD was 1.48 for DBS vs.1.32 for Plasma, and an average of log10 copies/mL of 5.32 vs. 5.53. ANOVA analysis did not show any statistically significant difference between the analyzed groups (p = 0.92. Conclusion The results provide strong evidence that the isolation and quantification of DNA-HBV from DBS is a viable alternative

  2. Use of dried blood samples for monitoring hepatitis B virus infection

    Science.gov (United States)

    Lira, Rosalia; Maldonado-Rodriguez, Angelica; Rojas-Montes, Othon; Ruiz-Tachiquin, Martha; Torres-Ibarra, Rocio; Cano-Dominguez, Carlos; Valdez-Salazar, Hilda; Gomez-Delgado, Alejandro; Muñoz, Onofre; Alvarez-Muñoz, Ma-Teresa

    2009-01-01

    Background Hepatitis B virus (HBV) infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS) have been successfully used to diagnose and monitor several infectious diseases. In Mexico there is an urgent need for an affordable and easy sampling method for viral load (VL) testing and monitoring of chronic HBV infection. The purpose of this work was to validate the utility of DBS samples for monitoring HBV infection in patients from Mexico City. Methods Matched samples of plasma and DBS on filter paper from 47 HBV infected patients from the Instituto Mexicano del Seguro Social (IMSS), were included. To evaluate the DNA stability and purity from DBS stored at different temperature conditions, samples from ten patients were stored at 4 degree, 25 degree, and 37 degree C for 7 days. After DBS elution and DNA extraction, the purity of these samples was determined measuring the O.D. rate 260/280. The DBS utility for molecular studies was assessed with PCR assays to amplify a 322 bp fragment from the "a" determinant region of the HBV "S" gene. The VL from all samples was determined to evaluate the correlation between plasma and DBS matched samples. Results The quality of the DNA from DBS specimen is not adversely affected by storage at 4 degree, 25 degree and 37 degree C for up 7 days. Statistical ANOVA analyses did not show any significant difference. The same amplification efficiency was observed between DNA templates from samples stored at different temperatures. The Pearson correlation between the VL from DBS and plasma matched samples was 0.93 (p = 0.01). The SD was 1.48 for DBS vs.1.32 for Plasma, and an average of log10 copies/mL of 5.32 vs. 5.53. ANOVA analysis did not show any statistically significant difference between the analyzed groups (p = 0.92). Conclusion The results provide strong evidence that the isolation and quantification of DNA-HBV from DBS is a viable alternative for patient monitoring

  3. Assessment of DDT and DDE levels in soil, dust, and blood samples from Chihuahua, Mexico.

    Science.gov (United States)

    Martínez, Fernando Díaz-Barriga; Trejo-Acevedo, Antonio; Betanzos, Angel F; Espinosa-Reyes, Guillermo; Alegría-Torres, Jorge Alejandro; Maldonado, Iván Nelinho Pérez

    2012-02-01

    The aim of this study was to assess levels of DDT and DDE in two environmental matrices (soil and dust) and to investigate the blood levels of these insecticides in exposed children living in a north Mexican state (Chihuahua) where DDT was sprayed several years ago during (1) health campaigns for the control of malaria and (2) agricultural activities. DDT and DDE were analyzed by gas chromatography/mass spectrometry. In general, lower levels were found in household outdoor samples. The levels in outdoor samples ranged from 0.001 to 0.788 mg/kg for DDT and from 0.001 to 0.642 mg/kg for DDE. The levels in indoor samples ranged from 0.001 to 15.47 mg/kg for DDT and from 0.001 to 1.063 mg/kg for DDE. Similar results to those found in indoor soil were found in dust, in which the levels ranged from 0.001 to 95.87 mg/kg for DDT and from 0.001 to 0.797 mg/kg for DDE. Moreover, blood levels showed that all of the communities studied had been exposed to DDT and/or DDE, indicating a general past or present exposure to DDT. It is important to note that the quotient DDT/DDE in all matrices was always >1. Whether the people living in our study area are at risk is an issue that deserves further analysis. However, applying precautionary principles, it is important to initiate a risk-reduction program to decrease exposure to DDT and its metabolites in people living in this area.

  4. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  5. Application of composite estimation in studies of animal population production with two-stage repeated sample designs.

    Science.gov (United States)

    Farver, T B; Holt, D; Lehenbauer, T; Greenley, W M

    1997-05-01

    This paper reports results from two example data sets of a two-stage sampling design where sampling (in panels) both farms and animals within selected farms increases the efficiency of parameter estimation from measurements recorded over time. With such a design, not only are farms replaced from time-to-time but also animals subsampled within retained farms are subject to replacement. Three general categories of parameters estimated for the population (the set of animals belonging to the universe of farms of interest) were (1) the total at each measurement occasion; (2) the difference between means or totals on successive measurement occasions; (3) the total over a sequence of successive measurement periods. Whereas several responses at the farm level were highly correlated over time (rho 1), the corresponding animal responses were less correlated over time (rho 2)-leading to only moderate gains in relative efficiency. Intraclass correlation values were too low in most cases to counteract the overall negative impact of rho 2. In general, sizeable gains in relative efficiency were observed for estimating change-confirming a previous result which showed this to be true provided that rho 1 was high (irrespective of rho 2).

  6. Concentrations of environmental contaminants in blood samples collected from Sharp-shinned hawks (Accipiter striatus) from the Eastern Flyway

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Table 1 provides the results of organochlorine and mercury analysis on plasma and whole blood samples (respectively) collected from 20 sharp-shinned hawks at HMS...

  7. DNA damage focus analysis in blood samples of minipigs reveals acute partial body irradiation.

    Directory of Open Access Journals (Sweden)

    Andreas Lamkowski

    Full Text Available Radiation accidents frequently involve acute high dose partial body irradiation leading to victims with radiation sickness and cutaneous radiation syndrome that implements radiation-induced cell death. Cells that are not lethally hit seek to repair ionizing radiation (IR induced damage, albeit at the expense of an increased risk of mutation and tumor formation due to misrepair of IR-induced DNA double strand breaks (DSBs. The response to DNA damage includes phosphorylation of histone H2AX in the vicinity of DSBs, creating foci in the nucleus whose enumeration can serve as a radiation biodosimeter. Here, we investigated γH2AX and DNA repair foci in peripheral blood lymphocytes of Göttingen minipigs that experienced acute partial body irradiation (PBI with 49 Gy (± 6% Co-60 γ-rays of the upper lumbar region. Blood samples taken 4, 24 and 168 hours post PBI were subjected to γ-H2AX, 53BP1 and MRE11 focus enumeration. Peripheral blood lymphocytes (PBL of 49 Gy partial body irradiated minipigs were found to display 1-8 DNA damage foci/cell. These PBL values significantly deceed the high foci numbers observed in keratinocyte nuclei of the directly γ-irradiated minipig skin regions, indicating a limited resident time of PBL in the exposed tissue volume. Nonetheless, PBL samples obtained 4 h post IR in average contained 2.2% of cells displaying a pan-γH2AX signal, suggesting that these received a higher IR dose. Moreover, dispersion analysis indicated partial body irradiation for all 13 minipigs at 4 h post IR. While dose reconstruction using γH2AX DNA repair foci in lymphocytes after in vivo PBI represents a challenge, the DNA damage focus assay may serve as a rapid, first line indicator of radiation exposure. The occurrence of PBLs with pan-γH2AX staining and of cells with relatively high foci numbers that skew a Poisson distribution may be taken as indicator of acute high dose partial body irradiation, particularly when samples are available

  8. A method to estimate dispersion in sampling catheters and to calculate dispersion-free blood time-activity curves

    OpenAIRE

    Munk, Ole Lajord; Keiding, Susanne; Bass, Ludvik

    2008-01-01

    The authors developed a transmission-dispersion model to estimate dispersion in blood sampling systems and to calculate dispersion-free input functions needed for kinetic analysis. Transport of molecules through catheters was considered in two parts: a central part with convective transmission of molecules and a stagnant layer that molecules may enter and leave. The authors measured dispersion caused by automatic and manual blood sampling using three PET tracers that distribute differently in...

  9. Clean Sampling of an Englacial Conduit at Blood Falls, Antarctica - Some Experimental and Numerical Results

    Science.gov (United States)

    Kowalski, Julia; Francke, Gero; Feldmann, Marco; Espe, Clemens; Heinen, Dirk; Digel, Ilya; Clemens, Joachim; Schüller, Kai; Mikucki, Jill; Tulaczyk, Slawek M.; Pettit, Erin; Berry Lyons, W.; Dachwald, Bernd

    2017-04-01

    There is significant interest in sampling subglacial environments for geochemical and microbiological studies, yet those environments are typically difficult to access. Existing ice-drilling technologies make it cumbersome to maintain microbiologically clean access for sample acquisition and environmental stewardship of potentially fragile subglacial aquatic ecosystems. With the "IceMole", a minimally invasive, maneuverable subsurface ice probe, we have developed a clean glacial exploration technology for in-situ analysis and sampling of glacial ice and sub- and englacial materials. Its design is based on combining melting and mechanical stabilization, using an ice screw at the tip of the melting head to maintain firm contact between the melting head and the ice. The IceMole can change its melting direction by differential heating of the melting head and optional side wall heaters. Downward, horizontal and upward melting, as well as curve driving and penetration of particulate-ladden layers has already been demonstrated in several field tests. This maneuverability of the IceMole also necessitates a sophisticated on-board navigation system, capable of autonomous operations. Therefore, between 2012 and 2014, a more advanced probe was developed as part of the "Enceladus Explorer" (EnEx) project. The EnEx-IceMole offers systems for accurate positioning, based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection, which is all integrated through a high-level sensor fusion algorithm. In December 2014, the EnEx-IceMole was used for clean access into a unique subglacial aquatic environment at Blood Falls, Antarctica, where an englacial brine sample was successfully obtained after about 17 meters of oblique melting. Particular attention was paid to clean protocols for sampling for geochemical and microbiological analysis. In this contribution, we will describe the general technological approach of the IceMole and report on the

  10. MalHaploFreq: A computer programme for estimating malaria haplotype frequencies from blood samples

    Directory of Open Access Journals (Sweden)

    Smith Thomas A

    2008-07-01

    Full Text Available Abstract Background Molecular markers, particularly those associated with drug resistance, are important surveillance tools that can inform policy choice. People infected with falciparum malaria often contain several genetically-distinct clones of the parasite; genotyping the patients' blood reveals whether or not the marker is present (i.e. its prevalence, but does not reveal its frequency. For example a person with four malaria clones may contain both mutant and wildtype forms of a marker but it is not possible to distinguish the relative frequencies of the mutant and wildtypes i.e. 1:3, 2:2 or 3:1. Methods An appropriate method for obtaining frequencies from prevalence data is by Maximum Likelihood analysis. A computer programme has been developed that allows the frequency of markers, and haplotypes defined by up to three codons, to be estimated from blood phenotype data. Results The programme has been fully documented [see Additional File 1] and provided with a user-friendly interface suitable for large scale analyses. It returns accurate frequencies and 95% confidence intervals from simulated dataset sets and has been extensively tested on field data sets. Additional File 1 User manual for MalHaploFreq. Click here for file Conclusion The programme is included [see Additional File 2] and/or may be freely downloaded from 1. It can then be used to extract molecular marker and haplotype frequencies from their prevalence in human blood samples. This should enhance the use of frequency data to inform antimalarial drug policy choice. Additional File 2 executable programme compiled for use on DOS or windows Click here for file

  11. Concentrations of cyanide in blood samples of corpses after smoke inhalation of varying origin.

    Science.gov (United States)

    Stoll, Simone; Roider, Gabriele; Keil, Wolfgang

    2017-01-01

    Cyanide (CN) blood concentration is hardly considered during routine when evaluating smoke gas intoxications and fire victims, although some inflammable materials release a considerable amount of hydrogen cyanide. CN can be significant for the capacity to act and can in the end even be the cause of death. Systematic data concerning the influence of different fire conditions, especially those of various inflammable materials, on the CN-blood concentration of deceased persons do not exist. This study measured the CN level in 92 blood samples of corpses. All persons concerned were found dead in connection with fires and/or smoke gases. At the same time, the carboxyhemoglobin (COHb) level was determined, and the corpses were examined to detect pharmaceutical substances, alcohol and drugs. Furthermore, we analysed autopsy findings and the investigation files to determine the inflammable materials and other circumstances of the fires. Due to the inflammable materials, the highest concentration of CN in the victims was found after enclosed-space fires (n = 45) and after motor-vehicle fires (n = 8). The CN levels in these two groups (n = 53) were in 47 % of the cases toxic and in 13 % of the cases lethal. In victims of charcoal grills (n = 17) and exhaust gases (n = 6), no or only traces of CN were found. Only one case of the self-immolations (n = 12) displayed a toxic CN level. The results show that CN can have considerable significance when evaluating action ability and cause of death with enclosed-space fires and with motor-vehicle fires.

  12. Determination of appropriate sampling frequency and time of multiple blood sampling dual exponential method with {sup 99m}Tc-DTPA for calculating GFR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chung Ho; O, Joo Hyun; Chung, Yong An; Yoo, Le Ryung; Sohn, Hyung Sun; Kim, Sung Hoon; Chung, Soo Kyo; Lee, Hyoung Koo [Catholic University of Korea, Seoul (Korea, Republic of)

    2006-02-15

    To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with {sup 99m}Tc-DTPA for calculating glomerular filtration rate (GFR). Thirty four patients were included in this study. Three mCi of {sup 99m}Tc-DTPA was intravenously injected and blood sampling at 9 different times, 5 ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's {tau} correlation coefficients, mean difference and standard deviation. Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient {tau} =0.93), minimal difference (Mean{+-}SD= -1.784{+-}3.972), and no over or underestimation as the renal function changed. Th 4-sample GFR showed no better accuracy than the 3-sample GFR. Int the wide spectrum or renal function, the 10-120-240 min 3-sample GFR could be the best choice for estimating the patients' renal function.

  13. Fetal blood sampling in twin pregnancies. Prenatal diagnosis and management of 19 cases.

    Science.gov (United States)

    Cox, W L; Forestier, F; Capella-Pavlovsky, M; Daffos, F

    1987-01-01

    Twin pregnancies pose particular problems in both prenatal diagnosis and obstetric management. We present 19 twin pregnancies that underwent fetal blood sampling (FBS). The indications were mostly similar to those for singleton pregnancies, with both fetuses being sampled. There was one indication specific to twin pregnancies; disseminated intravascular coagulation in the retained twin after the death-in-utero (DIU) of the other. In 5 cases, only 1 twin was sampled; in 2 because the second twin was female in the diagnosis of an X-linked disorder; in 1 because of technical failure, and in 2 the other twin had predeceased. Eight pregnancies continued after the FBS delivering 2 live, healthy infants, though 5 were delivered before 37 weeks of gestation. In 7 cases there was a discordance in the diagnosis between the twins. In 3 of these cases the affected fetus underwent selective termination by air embolism; in 2 cases the pregnancies were continued and the affected twin not resuscitated; 1 pregnancy is still in progress, and 1 patient had a non-medically supervised termination of both twins in another country. Two patients miscarried within a week of the FBS. Two patients had only 1 living twin at the time of FBS; 1 had a second DIU a month after the FBS and the other a neonatal death at 11 days of age in an infant with severe porencephaly. FBS is technically feasible for similar indications as for singleton pregnancies though discordance in diagnosis raises specific management problems.

  14. Reference values for lysosomal enzymes activities using dried blood spots samples - a Brazilian experience

    Directory of Open Access Journals (Sweden)

    Martins Ana M

    2010-09-01

    Full Text Available Abstract Background Lysosomal storage diseases (LSD are inherited disorders caused by deficiency of lysosomal enzymes in which early diagnosis is essential to provide timely treatment. This study reports interval values for the activity of lysosomal enzymes that are deficient in Mucopolysaccharidosis type I, Fabry, Gaucher and Pompe disease, using dried blood spots on filter paper (DBS samples in a Brazilian population. Results Reference activity values were obtained from healthy volunteers samples for alpha-galactosidase A (4.57 ± 1.37 umol/L/h, beta-glucosidase (3.06 ± 0.99 umol/L/h, alpha-glucosidase (ratio: 13.19 ± 4.26; % inhibition: 70.66 ± 7.60, alpha-iduronidase (3.45 ± 1.21 umol/L/h and beta-galactosidase (14.09 ± 4.36 umol/L/h. Conclusion Reference values of five lysosomal enzymes were determined for a Brazilian population sample. However, as our results differ from other laboratories, it highlights the importance of establishing specific reference values for each center.

  15. PERT: a method for expression deconvolution of human blood samples from varied microenvironmental and developmental conditions.

    Directory of Open Access Journals (Sweden)

    Wenlian Qiao

    Full Text Available The cellular composition of heterogeneous samples can be predicted using an expression deconvolution algorithm to decompose their gene expression profiles based on pre-defined, reference gene expression profiles of the constituent populations in these samples. However, the expression profiles of the actual constituent populations are often perturbed from those of the reference profiles due to gene expression changes in cells associated with microenvironmental or developmental effects. Existing deconvolution algorithms do not account for these changes and give incorrect results when benchmarked against those measured by well-established flow cytometry, even after batch correction was applied. We introduce PERT, a new probabilistic expression deconvolution method that detects and accounts for a shared, multiplicative perturbation in the reference profiles when performing expression deconvolution. We applied PERT and three other state-of-the-art expression deconvolution methods to predict cell frequencies within heterogeneous human blood samples that were collected under several conditions (uncultured mono-nucleated and lineage-depleted cells, and culture-derived lineage-depleted cells. Only PERT's predicted proportions of the constituent populations matched those assigned by flow cytometry. Genes associated with cell cycle processes were highly enriched among those with the largest predicted expression changes between the cultured and uncultured conditions. We anticipate that PERT will be widely applicable to expression deconvolution strategies that use profiles from reference populations that vary from the corresponding constituent populations in cellular state but not cellular phenotypic identity.

  16. PERT: a method for expression deconvolution of human blood samples from varied microenvironmental and developmental conditions.

    Science.gov (United States)

    Qiao, Wenlian; Quon, Gerald; Csaszar, Elizabeth; Yu, Mei; Morris, Quaid; Zandstra, Peter W

    2012-01-01

    The cellular composition of heterogeneous samples can be predicted using an expression deconvolution algorithm to decompose their gene expression profiles based on pre-defined, reference gene expression profiles of the constituent populations in these samples. However, the expression profiles of the actual constituent populations are often perturbed from those of the reference profiles due to gene expression changes in cells associated with microenvironmental or developmental effects. Existing deconvolution algorithms do not account for these changes and give incorrect results when benchmarked against those measured by well-established flow cytometry, even after batch correction was applied. We introduce PERT, a new probabilistic expression deconvolution method that detects and accounts for a shared, multiplicative perturbation in the reference profiles when performing expression deconvolution. We applied PERT and three other state-of-the-art expression deconvolution methods to predict cell frequencies within heterogeneous human blood samples that were collected under several conditions (uncultured mono-nucleated and lineage-depleted cells, and culture-derived lineage-depleted cells). Only PERT's predicted proportions of the constituent populations matched those assigned by flow cytometry. Genes associated with cell cycle processes were highly enriched among those with the largest predicted expression changes between the cultured and uncultured conditions. We anticipate that PERT will be widely applicable to expression deconvolution strategies that use profiles from reference populations that vary from the corresponding constituent populations in cellular state but not cellular phenotypic identity.

  17. Haematospirillum jordaniae gen. nov., sp. nov., isolated from human blood samples.

    Science.gov (United States)

    Humrighouse, B W; Emery, B D; Kelly, A J; Metcalfe, M G; Mbizo, J; McQuiston, J R

    2016-04-01

    A Gram-negative, aerobic, motile, spiral-shaped bacterium, strain H5569(T), was isolated from a human blood sample. Phenotypic and molecular characteristics of the isolate were investigated. Optimal growth was found to occur at 35 °C under aerobic conditions on Heart Infusion Agar supplemented with 5 % rabbit blood. The major fatty acids present in the cells were identified as C16:0, C16:1ω7c and C18:1ω7c. The predominant respiratory quinone was found to be ubiquinone-Q10. The G+C content of genomic DNA for strain H5569(T) was found to be 49.9 %. Based on 16S rRNA gene sequence analysis results, 13 additional isolates were also analysed in this study. Phylogenetic analysis based on 16S rRNA gene sequences revealed that the organism, represented by strain H5569(T), forms a distinct lineage within the family Rhodospirillaceae, closely related to two Novispirillum itersonii subspecies (93.9-94.1 %) and two Caenispirillum sp. (91.2-91.6 %). Based on these results, the isolate H5569(T) is concluded to represent a new genus and species for which the name Haematospirillum jordaniae gen. nov., sp. nov. is proposed. The type strain is H5569(T) (=DSM(T) 28903 = CCUG 66838(T)).

  18. Triclosan/triclocarban levels in maternal and umbilical blood samples and their association with fetal malformation.

    Science.gov (United States)

    Wei, Ling; Qiao, Pengyun; Shi, Ying; Ruan, Yan; Yin, Jie; Wu, Qingqing; Shao, Bing

    2017-03-01

    Triclosan (TCS) and triclocarban (TCC) are widely used as antimicrobial compounds in consumer products. TCS and TCC are frequently found in waste water and sewage. In this study, we investigate the potential impact of exposure to triclosan (TCS) and triclocarban (TCC) on fetal abnormalities. We measured TCS and TCC levels in maternal and umbilical cord blood samples from 39 pregnant women diagnosed with fetal or post-birth abnormalities at Beijing Obstetrics and Gynecology Hospital. 52 pregnant women who gave birth to healthy neonates during the same period of time were included as controls. Applying ultra-performance liquid chromatography-tandem mass spectrometry, TCS and TCC concentrations were measured in maternal and fetal sera. Significantly increased levels of TCS were detected in maternal sera from mothers with abnormal births. Similar levels of TCS or TCC were found in maternal and cord sera in control group. The concentrations of TCS or TCC in maternal sera correlated with those in umbilical cord sera (r=0.649, P<0.01). These observations suggest that maternal blood test could be a useful assay for detecting fetal exposure to TCS and TCC, and high exposure to TCS may be potentially associated with increased risk for fetal malformations.

  19. Preliminary Blood Pressure Screening in a Representative Sample of Extremely Obese Kuwaiti Adolescents

    Directory of Open Access Journals (Sweden)

    Rima Abdul Razzak

    2013-01-01

    Full Text Available A relationship between blood pressure (BP and obesity has been found in young adults, but no data are available for adolescents in Kuwait. 257 adolescent (11–19 years participants were categorized into two groups according to their BMI; 48 nonobese (21 males: 43.7% and 27 females: 56.3% with mean age of years and 209 obese (128 males: 61.25% and 81 females: 38.75% with mean age of years. The mean BMI was  kg/m2 for the nonobese group and  kg/m3 for the obese group. Most BP measures based on a single screening were significantly higher in the obese group. The prevalence of elevated BP was significantly higher in the obese subjects (nonobese: 13%; obese: 63%; . In the obese group, there was a significant positive correlation between total sample BMI and all BP measures except the pulse pressure. There was a similar rate of elevated blood pressure between males and females (64% versus 60%; . For both isolated systolic elevated BP and isolated diastolic elevated BP, the prevalences were comparable between the males (systolic: 42%; diastolic: 5% and females (systolic: 34%; diastolic: 14%. Only systolic BP was positively correlated with BMI in obese adolescent males (Spearman ; , with a significant correlation between BMI with diastolic (Spearman ; and mean BP (Spearman ; in females.

  20. Identifying the potential of changes to blood sample logistics using simulation

    DEFF Research Database (Denmark)

    Jørgensen, Pelle Morten Thomas; Jacobsen, Peter; Poulsen, Jørgen Hjelm

    2013-01-01

    in the laboratory were used as the evaluation criteria. Four different scenarios were tested and compared with the current approach: (1) Using AGVs (mobile robots), (2) using a pneumatic tube system, (3) using porters that are called upon, or (4) using porters that come to the wards every 45 minutes. Furthermore......, each of the scenarios was tested in terms of what amount of resources would give the optimal result. The simulations showed a big improvement potential in implementing a new technology/mean for transporting the blood samples. The pneumatic tube system showed the biggest potential lowering the AWT...... and MWT with approx. 36% and 18%, respectively. Additionally, all of the scenarios had a more even distribution of arrivals except for porters coming to the wards every 45 min. As a consequence of the results obtained in the study, the hospital decided to implement a pneumatic tube system....

  1. A policy of routine umbilical cord blood gas analysis decreased missing samples from high-risk births.

    Science.gov (United States)

    Ahlberg, M; Elvander, C; Johansson, S; Cnattingius, S; Stephansson, O

    2017-01-01

    This study compared obstetric units practicing routine or selective umbilical cord blood gas analysis, with respect to the risk of missing samples in high-risk deliveries and in infants with birth asphyxia. This was a Swedish population-based cohort study that used register data for 155 235 deliveries of live singleton infants between 2008 and 2014. Risk ratios and 95% confidence intervals were calculated to estimate the association between routine and selective umbilical cord blood gas sampling strategies and the risk of missing samples. Selective sampling increased the risk ratios when routine sampling was used as the reference, with a value of 1.0, and these were significant in high-risk deliveries and birth asphyxia. The risk ratios for selective sampling were large-for-gestational age (9.07), preterm delivery at up to 36 weeks of gestation (8.24), small-for-gestational age (7.94), two or more foetal scalp blood samples (5.96), an Apgar score of less than seven at one minute (2.36), emergency Caesarean section (1.67) and instrumental vaginal delivery (1.24). Compared with routine sampling, selective umbilical cord blood gas sampling significantly increased the risks of missing samples in high-risk deliveries and in infants with birth asphyxia. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Analysis of hemoglobin adducts from acrylamide, glycidamide, and ethylene oxide in paired mother/cord blood samples from Denmark

    DEFF Research Database (Denmark)

    von Stedingk, Hans; Vikström, Anna C; Rydberg, Per

    2011-01-01

    for analysis of Hb adducts by liquid chromatography-mass spectrometry, the adduct FIRE procedure, was applied to measurements of adducts from these compounds in maternal blood samples (n = 87) and umbilical cord blood samples (n = 219). The adduct levels from the three compounds, acrylamide, glycidamide......, and ethylene oxide, were increased in tobacco smokers. Highly significant correlations were found between cord and maternal blood with regard to measured adduct levels of the three compounds. The mean cord/maternal hemoglobin adduct level ratios were 0.48 (range 0.27-0.86) for acrylamide, 0.38 (range 0.......20-0.73) for glycidamide, and 0.43 (range 0.17-1.34) for ethylene oxide. In vitro studies with acrylamide and glycidamide showed a lower (0.38-0.48) rate of adduct formation with Hb in cord blood than with Hb in maternal blood, which is compatible with the structural differences in fetal and adult Hb. Together...

  3. Decreased mitochondrial DNA content in blood samples of patients with stage I breast cancer

    Directory of Open Access Journals (Sweden)

    Fokas Emmanouil

    2009-12-01

    Full Text Available Abstract Background Alterations of mitochondrial DNA (mtDNA have been implicated in carcinogenesis. We developed an accurate multiplex quantitative real-time PCR for synchronized determination of mtDNA and nuclear DNA (nDNA. We sought to investigate whether mtDNA content in the peripheral blood of breast cancer patients is associated with clinical and pathological parameters. Methods Peripheral blood samples were collected from 60 patients with breast cancer and 51 age-matched healthy individuals as control. DNA was extracted from peripheral blood for the quantification of mtDNA and nDNA, using a one-step multiplex real-time PCR. A FAM labeled MGB probe and primers were used to amplify the mtDNA sequence of the ATP 8 gene, and a VIC labeled MGB probe and primers were employed to amplify the glyceraldehyde-3-phosphate-dehydrogenase gene. mtDNA content was correlated with tumor stage, menstruation status, and age of patients as well as lymph node status and the expression of estrogen receptor (ER, progesterone receptor (PR and Her-2/neu protein. Results The content of mtDNA in stage I breast cancer patients was significantly lower than in other stages (overall P = 0.023. Reduced mtDNA was found often in post menopausal cancer group (P = 0.024. No difference in mtDNA content, in regards to age (p = 0.564, lymph node involvement (p = 0.673, ER (p = 0.877, PR (p = 0.763, and Her-2/neu expression (p = 0.335, was observed. Conclusion Early detection of breast cancer has proved difficult and current detection methods are inadequate. In the present study, decreased mtDNA content in the peripheral blood of patients with breast cancer was strongly associated with stage I. The use of mtDNA may have diagnostic value and further studies are required to validate it as a potential biomarker for early detection of breast cancer.

  4. Preterm Cord Blood Contains a Higher Proportion of Immature Hematopoietic Progenitors Compared to Term Samples.

    Directory of Open Access Journals (Sweden)

    Marina Podestà

    Full Text Available Cord blood contains high number of hematopoietic cells that after birth disappear. In this paper we have studied the functional properties of the umbilical cord blood progenitor cells collected from term and preterm neonates to establish whether quantitative and/or qualitative differences exist between the two groups.Our results indicate that the percentage of total CD34+ cells was significantly higher in preterm infants compared to full term: 0.61% (range 0.15-4.8 vs 0.3% (0.032-2.23 p = 0.0001 and in neonates <32 weeks of gestational age (GA compared to those ≥32 wks GA: 0.95% (range 0.18-4.8 and 0.36% (0.15-3.2 respectively p = 0.0025. The majority of CD34+ cells co-expressed CD71 antigen (p<0.05 preterm vs term and grew in vitro large BFU-E, mostly in the second generation. The subpopulations CD34+CD38- and CD34+CD45- resulted more represented in preterm samples compared to term, conversely, Side Population (SP did not show any difference between the two group. The absolute number of preterm colonies (CFCs/10microL resulted higher compared to term (p = 0.004 and these progenitors were able to grow until the third generation maintaining an higher proportion of CD34+ cells (p = 0.0017. The number of colony also inversely correlated with the gestational age (Pearson r = -0.3001 p<0.0168.We found no differences in the isolation and expansion capacity of Endothelial Colony Forming Cells (ECFCs from cord blood of term and preterm neonates: both groups grew in vitro large number of endothelial cells until the third generation and showed a transitional phenotype between mesenchymal stem cells and endothelial progenitors (CD73, CD31, CD34 and CD144The presence, in the cord blood of preterm babies, of high number of immature hematopoietic progenitors and endothelial/mesenchymal stem cells with high proliferative potential makes this tissue an important source of cells for developing new cells therapies.

  5. Blood typing

    Science.gov (United States)

    A blood sample is needed. The test to determine your blood group is called ABO typing. Your blood sample is mixed with antibodies against type A and B blood. Then, the sample is checked to see whether ...

  6. Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task.

    Directory of Open Access Journals (Sweden)

    Matthew E Downs

    Full Text Available Focused Ultrasound (FUS coupled with intravenous administration of microbubbles (MB is a non-invasive technique that has been shown to reliably open (increase the permeability of the blood-brain barrier (BBB in multiple in vivo models including non-human primates (NHP. This procedure has shown promise for clinical and basic science applications, yet the safety and potential neurological effects of long term application in NHP requires further investigation under parameters shown to be efficacious in that species (500 kHz, 200-400 kPa, 4-5 μm MB, 2 minute sonication. In this study, we repeatedly opened the BBB in the caudate and putamen regions of the basal ganglia of 4 NHP using FUS with systemically-administered MB over 4-20 months. We assessed the safety of the FUS with MB procedure using MRI to detect edema or hemorrhaging in the brain. Contrast enhanced T1-weighted MRI sequences showed a 98% success rate for openings in the targeted regions. T2-weighted and SWI sequences indicated a lack edema in the majority of the cases. We investigated potential neurological effects of the FUS with MB procedure through quantitative cognitive testing of' visual, cognitive, motivational, and motor function using a random dot motion task with reward magnitude bias presented on a touchpanel display. Reaction times during the task significantly increased on the day of the FUS with MB procedure. This increase returned to baseline within 4-5 days after the procedure. Visual motion discrimination thresholds were unaffected. Our results indicate FUS with MB can be a safe method for repeated opening of the BBB at the basal ganglia in NHP for up to 20 months without any long-term negative physiological or neurological effects with the parameters used.

  7. Utility of the microculture method for Leishmania detection in non-invasive samples obtained from a blood bank.

    Science.gov (United States)

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Kocazeybek, Bekir; Kosan, Erdogan

    2013-10-01

    In recent years, the role of donor blood has taken an important place in epidemiology of Leishmaniasis. According to the WHO, the numbers of patients considered as symptomatic are only 5-20% of individuals with asymptomatic leishmaniasis. In this study for detection of Leishmania infection in donor blood samples, 343 samples from the Capa Red Crescent Blood Center were obtained and primarily analyzed by microscopic and serological methods. Subsequently, the traditional culture (NNN), Immuno-chromatographic test (ICT) and Polymerase Chain Reaction (PCR) methods were applied to 21 samples which of them were found positive with at least one method. Buffy coat (BC) samples from 343 blood donors were analyzed: 15 (4.3%) were positive by a microculture method (MCM); and 4 (1.1%) by smear. The sera of these 343 samples included 9 (2.6%) determined positive by ELISA and 7 (2%) positive by IFAT. Thus, 21 of (6.1%) the 343 subjects studied by smear, MCM, IFAT and ELISA techniques were identified as positive for leishmaniasis at least one of the techniques and the sensitivity assessed. According to our data, the sensitivity of the methods are identified as MCM (71%), smear (19%), IFAT (33%), ELISA (42%), NNN (4%), PCR (14%) and ICT (4%). Thus, with this study for the first time, the sensitivity of a MCM was examined in blood donors by comparing MCM with the methods used in the diagnosis of leishmaniasis. As a result, MCM was found the most sensitive method for detection of Leishmania parasites in samples obtained from a blood bank. In addition, the presence of Leishmania parasites was detected in donor bloods in Istanbul, a non-endemic region of Turkey, and these results is a vital importance for the health of blood recipients.

  8. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  9. Slurry sampling in serum blood for mercury determination by CV-AFS

    Energy Technology Data Exchange (ETDEWEB)

    Aranda, Pedro R. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: paranda@unsl.edu.ar; Gil, Raul A. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: ragil@unsl.edu.ar; Moyano, Susana [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: smoyano@unsl.edu.ar; De Vito, Irma [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: devito@unsl.edu.ar; Martinez, Luis D. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: ldm@unsl.edu.ar

    2009-01-30

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 {mu}g L{sup -1} Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L{sup -1} and the relative standard deviation was 3.9% at levels around of 0.4 {mu}g L{sup -1} Hg.

  10. Sample preparation and in situ hybridization techniques for automated molecular cytogenetic analysis of white blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Rijke, F.M. van de; Vrolijk, H.; Sloos, W. [Leiden Univ. (Netherlands)] [and others

    1996-06-01

    With the advent in situ hybridization techniques for the analysis of chromosome copy number or structure in interphase cells, the diagnostic and prognostic potential of cytogenetics has been augmented considerably. In theory, the strategies for detection of cytogenetically aberrant cells by in situ hybridization are simple and straightforward. In practice, however, they are fallible, because false classification of hybridization spot number or patterns occurs. When a decision has to be made on molecular cytogenetic normalcy or abnormalcy of a cell sample, the problem of false classification becomes particularly prominent if the fraction of aberrant cells is relatively small. In such mosaic situations, often > 200 cells have to be evaluated to reach a statistical sound figure. The manual enumeration of in situ hybridization spots in many cells in many patient samples is tedious. Assistance in the evaluation process by automation of microscope functions and image analysis techniques is, therefore, strongly indicated. Next to research and development of microscope hardware, camera technology, and image analysis, the optimization of the specimen for the (semi)automated microscopic analysis is essential, since factors such as cell density, thickness, and overlap have dramatic influences on the speed and complexity of the analysis process. Here we describe experiments that have led to a protocol for blood cell specimen that results in microscope preparations that are well suited for automated molecular cytogenetic analysis. 13 refs., 4 figs., 1 tab.

  11. [Detection of antibodies against Trypanosoma cruzi in Somoto, Nicaragua, using indirect ELISA and IFI on blood samples on filter paper].

    Science.gov (United States)

    Palacios, X; Belli, A; Espino, A M

    2000-12-01

    We standardized a solid-phase enzyme-linked immunosorbent assay (ELISA) in order to study the presence of Trypanosoma cruzi antibodies in asymptomatic persons who live in an area of Nicaragua endemic for Chagas' disease. The test was standardized to analyze filter-paper blood samples, which are easy to transport. In the first phase of our investigation, ELISA was used to study 18 samples of total serum and 18 eluates of blood from patients with chronic Chagas' disease; 30 samples of serum and 30 eluates of blood from healthy people, used as negative controls; and 14 samples of serum and 14 eluates of blood from patients with cutaneous or visceral leishmaniasis, which were used to study cross-reactions. Both with the total-serum and the blood-eluate samples, the ELISA test provided 100% sensitivity and 90% specificity. Cross-reactions in the patient samples were observed only with visceral leishmaniasis. The second phase of our investigation was a population study that included eight rural communities in the area of Somoto, Nicaragua. Through random sampling, filter-paper blood samples were collected from 2,434 people (1,335 men and 1,099 women) from the communities of Aguas Calientes, El Brocal, La Manzana, Las Playas, Los Canales, Santa Isabel, Santa Rosa, and Santa Teresa. Studied by ELISA and by indirect immunofluorescence (IIF), the samples included 260 found seropositive by ELISA (10.7%), of which 207 were positive according to IIF (8.5%). With both techniques, the majority of seropositives were among women, but the difference between men and women was not statistically significant. There was a high level of agreement between the results obtained with the two techniques. There was an upward trend with age, with 5.4% of those found seropositive by ELISA being persons 10 years of age or younger and 42.7% of those found seropositive being older than 50. The vast majority of the individuals analyzed were asymptomatic.

  12. Blood

    Science.gov (United States)

    ... Also, blood is either Rh-positive or Rh-negative. So if you have type A blood, it's either A positive or A negative. Which type you are is important if you need a blood transfusion. And your Rh factor could be important ...

  13. Quantification of cerebral blood flow with {sup 99m}Tc-ECD SPECT by a single arterial or venous blood sample

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo; Takahashi, Makoto; Noguchi, Eikichi; Ohtaki, Hiro; Shibaki, Mitsurou; Dobashi, Sachio [Niigata Univ. (Japan). School of Medicine; Ohkubo, Masaki

    1997-12-01

    The purpose of the study is to develop a simple and less invasive method for quantifying regional cerebral blood flow (rCBF) using {sup 99m}Tc-ECD and SPECT. By employing a microsphere model, a new method to measure rCBF was developed, which required a single arterial or venous sample instead of continuous withdrawal of arterial blood. Using a regression line, the integral of input function of arterial blood from 0 to 30 min was inferred by activity of arterial blood sampled at time t; A(t), by activity multiplied by its octanol extraction rate; A{sub N}(t), by activity of venous blood at time t; V(t), and by activity multiplied by its octanol extraction rate; V{sub N}(t). The optimum sampling time of arterial or venous blood was examined when mean % error for inference became minimum. Consequently, minimum error of A{sub N}(6 min) was 5.5%, A(3 min) was 8.9%, V{sub N}(6 min) was 5.9%, and V(20 min) was 10.0%. Quantitative measurement of rCBF using the value of V{sub N}(6 min) was performed on other 6 subjects with dementia etc. To validate the method, {sup 133}Xe inhalation SPECT studies were also performed on the same subjects. We found a good agreement between them (r=0.851). The presented one-point sampling methods were simple and less invasive for quantifying rCBF. (author)

  14. Effect of Familiar Olfactory Stimulus on Responses to Blood Sampling Pain in Neonates

    Directory of Open Access Journals (Sweden)

    A. Sadathosseini

    2011-04-01

    Full Text Available Introduction & Objective: Pain in neonates can lead to various risks. So, it seems essential to find a simple, safe, and acceptable method for relieving pain. The objective of this study was to assess the effectiveness of olfactory stimuli (familiar and unfamiliar on physiological and behavioral responses to the pain of arterial blood draws in term neonates. Materials & Methods: In this quasi-experimental clinical trial, according to the conditions of the study 135 term neonates were chosen by convenience sampling and were assigned to three groups. During the procedure, familiar odor group was presented with the vanilla smell with which they had been familiarized prior to the procedure for 9 hours. Unfamiliar odor group was presented with the vanilla smell to which they had not been previously exposed, and the control group was presented with no odor. The heart rate and O2 saturation levels were measured before, after inserting and after removing the needle. Also, their cry duration was measured from onset until a crying free interval of more than five seconds. Results: The infants exposed to the familiar odor cried significantly less during the procedure compared to the unfamiliar odor and no odor group (P<0.001. Moreover, there was no statistically significant difference in the heart rate among the groups after inserting and removing the needle and in the O2 saturation rate after inserting the needle. The O2 saturation rate was significantly higher in the familiar odor group compared with the other groups (p<0.05 after the needle removal. Conclusion: A familiar odor is effective in reducing crying during arterial blood draws in neonates, but does not affect on physiological parameters. (Sci J Hamadan Univ Med Sci 2011;18(1:10-19

  15. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    OpenAIRE

    Taylor, Brian. J.; Martin, Kimberly A; Arango, Eliana; Agudelo, Olga M; Maestre, Amanda; Yanow, Stephanie K.

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical s...

  16. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  17. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K;

    2001-01-01

    Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic....... Hepatic arterial and portal venous blood samples and flows were measured during the scan. The dual-input function was calculated as the flow-weighted input. RESULTS: For both MG and FDG, the compartmental analysis using arterial input led to systematic underestimation of the rate constants for rapid blood...... of conventional arterial sampling underestimated these parameters compared with independent measurements of hepatic flow and hepatic blood volume. In contrast, the linear Gjedde-Patlak analysis, being less informative but more robust, gave similar parameter estimates (K, V) with both input functions...

  18. Determination of the ideal sampling technique to reduce repeated procedures:a comparative study including 393 fine-needle aspirations for thyroid nodules.

    Science.gov (United States)

    Uzunkaya, Fatih; Özden, Ahmet

    2017-02-27

    Fine-needle aspiration biopsy is an established method for the evaluation of thyroid nodules, but it has not been standardized worldwide yet. Adequacy of the aspirations is affected by several factors. The aim of this study is to determine the main factors affecting the adequacy and to suggest a procedural technique expected to reduce repeated procedures. A total of 393 aspiration procedures performed using either 22-gauge or 27-gauge needles were included in the study. The samplings were classified as inadequate or adequate according to the cytopathological reports, and results were compared. The rate of adequate samplings was higher in the 27-gauge group and the difference was statistically significant. Neither the size of nodules nor the number of slides used for smearing affected the adequacy. There was not a statistically significant relation between the needle size and the nodule size or the number of slides in terms of adequacy. Needle size is an important factor that affects the adequacy of samplings. The nodule size and the number of slides do not affect the adequacy. However, bloody and thicker smears are difficult for pathologists to evaluate and result in inadequacy.

  19. Studying the Effect of Programmed Instruction on Performance and Venous Blood Sampling Error before sending the Samples to the laboratory at Selected Hospitals in Ilam in 2015

    Directory of Open Access Journals (Sweden)

    Ali Sahebi

    2016-12-01

    Full Text Available One of the common methods of diagnosis in intensive care units of blood is phlebotomy that requires knowledge and skill of the nurses. Respecting blood taking safety is of the most important topics in nursing care and its great impact on the reduction of pre-analytic errors has been detected. Considering the importance of roles nurses in accurate blood collection, and relevant nursing care, this study was conducted to investigate the effect of educational intervention Programmed instruction methods on the reduction of pre-analytic errors of the selected intensive care units of the education and health centers affiliated with Ilam University of Medical Sciences. This study was quasi-experimental of single group conducted through pre-test and post-test method. The used tools include the questionnaire of demographic data and measuring the performance of nurses about venous blood sampling and the check list of assessment of the compliance of venous blood sampling process by nurses with guidelines adopted in this regard. SPSS 16 was used to analyze the data.The descriptive statistics mean, standard deviation, frequency and percentage were used. In inferential statistics, ANOVA and chi-square tests were used. The results indicated a significant relationship between demographic variables gender, work experience, and type of employment and the observed error rate was statistically significant.

  20. Blood and urine samples as useful sources for the direct detection of tuberculosis by polymerase chain reaction.

    Science.gov (United States)

    Rebollo, María J; San Juan Garrido, Rafael; Folgueira, Dolores; Palenque, Elia; Díaz-Pedroche, C; Lumbreras, Carlos; Aguado, José M

    2006-10-01

    The aim of the study was to assess the utility of the polymerase chain reaction (PCR) assay in blood and urine for the diagnosis of tuberculosis (TB). We prospectively evaluated the usefulness of PCR performed in blood and urine samples from patients with proved or probable TB compared with a control group of patients. The PCR technique was performed using IS6110 primers. We included in the study 57 patients (43 with definite TB and 14 with probable TB) and 26 controls. Blood and urine samples were drawn at the time of microbiologic diagnosis and 3, 6, 9, and 12 months later. Cultures were positive in the early period (<1 month after treatment) in 11 of 57 patients (19%) with probable or definite TB, in comparison with 42% of patients (24/57) who yielded a positive PCR (P = 0.02). Urine samples increased the sensitivity of PCR determination in blood samples by 10%. The PCR in blood and/or urine was positive in 41% of patients with pulmonary TB, in 36% of patients with extrapulmonary TB, and in 50% of patients with disseminated TB. Mycobacterium tuberculosis was still detectable by PCR in 5 of 13 patients with cured TB after 1 or more months of antituberculous treatment. The PCR detection of M. tuberculosis in blood and urine samples is useful for the diagnosis of different clinical forms of TB, mostly in those patients in which sample extraction is difficult or requires aggressive techniques. The sensitivity of this technique could be improved studying more than 1 sample in each patient, even after initiating an antituberculous treatment.

  1. Single blood-Hg samples can result in exposure misclassification: temporal monitoring within the Japanese community (United States

    Directory of Open Access Journals (Sweden)

    Tsuchiya Ami

    2012-06-01

    Full Text Available Abstract Background The most prominent non-occupational source of exposure to methylmercury is the consumption of fish. In this study we examine a fish consuming population to determine the extent of temporal exposure and investigate the extent to which single time estimates of methylmercury exposure based on blood-Hg concentration can provide reliable estimates of longer-term average exposure. Methods Blood-mercury levels were obtained from a portion of the Arsenic Mercury Intake Biometric Study (AMIBS cohort. Specifically, 56 Japanese women residing in the Puget Sound area of Washington State, US were sampled on three occasions across a one-year period. Results An average of 135 days separated samples, with mean blood-mercury levels for the visits being 5.1, 6.6 and 5.0 μg/l and geometric means being 2.7, 4.5 and 3.1 μg/l. The blood-mercury levels in this group exceed national averages with geometric means for two of the visits being between the 90th and 95th percentiles of nationally observed levels and the lowest geometric mean being between the 75th and 90th percentile. Group means were not significantly different across sampling periods suggesting that exposure of combined subjects remained relatively constant. Comparing intra-individual results over time did not reveal a strong correlation among visits (r = 0.19, 0.50, 0.63 between 1st and 2nd, 2nd and 3rd, and 1st and 3rd sample results, respectively. In comparing blood-mercury levels across two sampling interval combinations (1st and 2nd, 2nd and 3rd, and 1st and 3rd visits, respectively, 58% (n = 34, 53% (n = 31 and 29% (n = 17 of the individuals had at least a 100% difference in blood-Hg levels. Conclusions Point estimates of blood-mercury, when compared with three sample averages, may not reflect temporal variability and individual exposures estimated on the basis of single blood samples should be treated with caution as indicators of long-term exposure

  2. A dried blood spots technique based LC-MS/MS method for the analysis of posaconazole in human whole blood samples.

    Science.gov (United States)

    Reddy, Todime M; Tama, Cristina I; Hayes, Roger N

    2011-11-15

    A rugged and robust liquid chromatographic tandem mass spectrometric (LC-MS/MS) method utilizing dried blood spots (DBS) was developed and validated for the analysis of posaconazole in human whole blood. Posaconazole fortified blood samples were spotted (15 μL) onto Ahlstrom Alh-226 DBS cards and dried for at least 2h. Punched spots were then extracted by using a mixture of acetonitrile and water containing stable labeled internal standard (IS). Posaconazole and its IS were separated from endogenous matrix components on a Kinetex™ C18 column under gradient conditions with a mobile phase A consisting of 0.1% formic acid and a mobile phase B consisting of 0.1% formic acid in acetonitrile/methanol (70/30, v/v). The analyte and IS were detected using a Sciex API 4000 triple quadrupole LC-MS/MS system equipped with a TurboIonSpray™ source operated in the positive ion mode. The assay was linear over the concentration range of 5-5000 ng/mL. The inter-run accuracy and precision of the assay were -1.8% to 0.8% and 4.0% to 10.4%, respectively. Additional assessments unique to DBS were investigated including sample spot homogeneity, spot volume, and hematocrit. Blood spot homogeneity was maintained and accurate and precise quantitation results were obtained when using a blood spot volume of between 15 and 35 μL. Human blood samples with hematocrit values ranging between 25% and 41% gave acceptable quantitation results. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible.

  3. Correction of an input function for errors introduced with automated blood sampling

    Energy Technology Data Exchange (ETDEWEB)

    Schlyer, D.J.; Dewey, S.L. [Brookhaven National Lab., Upton, NY (United States)

    1994-05-01

    Accurate kinetic modeling of PET data requires an precise arterial plasma input function. The use of automated blood sampling machines has greatly improved the accuracy but errors can be introduced by the dispersion of the radiotracer in the sampling tubing. This dispersion results from three effects. The first is the spreading of the radiotracer in the tube due to mass transfer. The second is due to the mechanical action of the peristaltic pump and can be determined experimentally from the width of a step function. The third is the adsorption of the radiotracer on the walls of the tubing during transport through the tube. This is a more insidious effect since the amount recovered from the end of the tube can be significantly different than that introduced into the tubing. We have measured the simple mass transport using [{sup 18}F]fluoride in water which we have shown to be quantitatively recovered with no interaction with the tubing walls. We have also carried out experiments with several radiotracers including [{sup 18}F]Haloperidol, [{sup 11}C]L-deprenyl, [{sup 18}]N-methylspiroperidol ([{sup 18}F]NMS) and [{sup 11}C]buprenorphine. In all cases there was some retention of the radiotracer by untreated silicone tubing. The amount retained in the tubing ranged from 6% for L-deprenyl to 30% for NMS. The retention of the radiotracer was essentially eliminated after pretreatment with the relevant unlabeled compound. For example less am 2% of the [{sup 18}F]NMS was retained in tubing treated with unlabelled NMS. Similar results were obtained with baboon plasma although the amount retained in the untreated tubing was less in all cases. From these results it is possible to apply a mathematical correction to the measured input function to account for mechanical dispersion and to apply a chemical passivation to the tubing to reduce the dispersion due to adsorption of the radiotracer on the tubing walls.

  4. Selective nonenzymatic bilirubin detection in blood samples using a Nafion/Mn-Cu sensor.

    Science.gov (United States)

    Noh, Hui-Bog; Won, Mi-Sook; Shim, Yoon-Bo

    2014-11-15

    The specific detection of biological organics without the use of an enzyme is challenging, and it is crucial for analytical and clinical chemistry. We report specific nonenzymatic bilirubin detection through the catalytic oxidation of bilirubin molecule on the Nafion/Mn-Cu surface. The catalytic ability, true surface area, morphology, crystallinity, composition, and oxidation state of the sensor surface were assessed using voltammetry, coulometry, XPS, XRD, Brunauer-Emmett-Teller (BET), SEM, EDXS, and TOF-SIMS experiments. The results showed that the surface was composed of microporous Mn-Cu bimetallic crystal in flake shape with a large BET surface area (3.635 m(2)g(-1)), where the surface area and crystallinity mainly affected the sensor performance. Product analysis of the catalytic reaction on the sensor probe revealed a specific two-electron oxidation of dipyrromethane moiety to dipyrromethene in the bilirubin molecule. Experimental variables affecting the analysis of bilirubin were optimized in terms of probe composition, temperature, pH, and potential. At the optimized condition, the dynamic range was between 1.2 μM and 0.42 mM, which yielded the equation of ΔI (μA)=(1.03 ± 0.72)+(457.0 ± 4.03) [C] (mM) with 0.999 of correlation coefficient, and the detection limit was 25.0 ± 1.8 nM (n=5, k=3). The stability test, interference effects, and analysis of real clinical samples, human whole blood and certified serum samples were demonstrated to confirm the reliability of the proposed bilirubin sensor.

  5. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K

    2001-01-01

    parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min....... Hepatic arterial and portal venous blood samples and flows were measured during the scan. The dual-input function was calculated as the flow-weighted input. RESULTS: For both MG and FDG, the compartmental analysis using arterial input led to systematic underestimation of the rate constants for rapid blood...

  6. Development of a statistical model for predicting the ethanol content of blood from measurements on saliva or breath samples.

    Science.gov (United States)

    Ruz, J; Linares, P; Luque de Castro, M D; Caridad, J M; Valcarcel, M

    1989-01-01

    Blood, saliva and breath samples from a population of males and females subjected to the intake of preselected amounts of ethanol, whilst in different physical conditions (at rest, after physical exertion, on an empty stomach and after eating), were analysed by automatic methods employing immobilized (blood) or dissolved (saliva) enzymes and a breathanalyser. Treatment of the results obtained enabled the development of a statistical model for prediction of the ethanol concentration in blood at a given time from the ethanol concentration in saliva or breath obtained at a later time.

  7. Assessment of the levels of DDT and DDE in soil and blood samples from Tabasco, Mexico.

    Science.gov (United States)

    Torres-Dosal, Arturo; Martinez-Salinas, Rebeca Isabel; Hernandez-Benavides, Diego; Perez-Vazquez, Francisco Javier; Ilizaliturri-Hernandez, Cesar; Perez-Maldonado, Ivan Nelinho

    2012-12-01

    In Mexico, 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) was used until the year 2000, principally in agriculture and anti-paludal program health campaigns. The southeastern region of Mexico was an important area of malaria, and from 1957 DDT was applied indoors every 6 months, with a coverage of 2 g/m(2). The current study was performed in Tabasco, a Mexican state located in the southeastern region of Mexico. DDT and 1,1-dichloro-2,2-bis(4-chlorophenyl)ethene (DDE) were analyzed by gas chromatography/mass spectrometry. In general, low levels were found in household outdoor samples; the levels of DDT ranged from not detectable to 0.048 mg/kg, and of DDE from 0.001 to 0.068 mg/kg. An important finding was that, in all communities where DDT in blood was analyzed, exposure to DDT was found, indicating both past and present exposure. Although the levels found in this study were lower than other studies in Mexico, there is a need to evaluate whether the people living in the study area are at risk.

  8. Standardization developments for large scale biobanks in smoking related diseases - a model system for blood sample processing and storage.

    Science.gov (United States)

    Malm, Johan; Fehniger, Thomas E; Danmyr, Pia; Végvári, Ákos; Welinder, Charlotte; Lindberg, Henrik; Upton, Paul; Carter, Stephanie; Appelqvist, Roger; Sjödin, Karin; Wieslander, Elisabet; Dahlbäck, Magnus; Rezeli, Melinda; Erlinge, David; Marko-Varga, György

    2013-12-01

    Biobank samples stored in biobanks give researchers and respiratory healthcare institutions access to datasets of analytes valuable for both diagnostic and research practices. The usefulness of these samples in clinical decision-making is highly dependent on their quality and integrity. New procedures that better preserve sample integrity and reduce degradation are being developed to meet the needs of both present and future biobanking. Hereby we present an automatic sample workflow scheme that is designed to handle high numbers of blood samples. Blood fractions are aliquoted, heat sealed using novel technology, and stored in 384 tube high-density sample arrays. The newly developed 384 biobank rack system is especially suited for preserving identical small aliquots. We provide data on robotic processing of clinical samples at -80°C, following initial processing, analysis and shipping between laboratories throughout Europe. Subsequent to unpacking, re-sorting, and storage at these sites, the samples have been returned for analysis. Biomarker analysis of 13 common tests in the clinical chemistry unit of the hospital provides evidence of qualitative and stable logistics using the 384-sample tube system. This technology development allows rapid access to a given sample in the frozen archive while maintaining individual sample integrity with sample tube confinement and quality management.

  9. Assessment of the quality and quantity of genomic DNA recovered from canine blood samples by three different extraction methods.

    Science.gov (United States)

    Clements, Dylan N; Wood, Shona; Carter, Stuart D; Ollier, William E R

    2008-08-01

    The ideal method for genomic DNA (gDNA) extraction should recover high quantities of pure, integral gDNA from the original sample source with minimal co-extraction of inhibitors of downstream processes. Canine ethylenediamine tetra-acetic acid (EDTA) treated and clotted blood samples were extracted by three different methods (a silica column method, a phenol-chloroform method and a modified salt precipitation method). Phenol-chloroform and modified salt precipitation based extractions demonstrated similar relative recovery of gDNA with EDTA preserved blood, but were less efficient at recovering gDNA from clotted blood. Spectrophotometer measurement of phenol-chloroform based extractions tended to overestimate the quantity of gDNA recovered from extractions, and was associated with the greater co-extraction of PCR inhibitors. The silica column method recovered gDNA with equal efficiency, purity and integrity irrespective of the sample type or method of quantification.

  10. Comparative determination of methyl mercury in whole blood samples using GC-ICP-MS and GC-MS techniques.

    Science.gov (United States)

    Hippler, J; Hoppe, H W; Mosel, F; Rettenmeier, A W; Hirner, A V

    2009-08-15

    Two methods for the determination of methyl mercury (MeHg) in whole blood samples based on different mass spectrometric detection techniques are compared. The methods were employed in two studies in which the internal exposure of a group of mercury-exposed workers to total mercury and MeHg was investigated. Blood samples of these workers were analysed for MeHg independently from each other in two laboratories using similar extraction procedures but different detection techniques, viz. coupled GC-EI-MS/ICP-MS and GC-MS using D(3)-MeHg as internal standard. MeHg was detected in all blood samples in concentrations ranging from 0.3 to 9.0 microg/L. Though different detection techniques were employed, the results obtained by the two laboratories were in relatively good agreement.

  11. Arterial blood gas analysis of samples directly obtained beyond cerebral arterial occlusion during endovascular procedures predicts clinical outcome.

    Science.gov (United States)

    Flores, Alan; Sargento-Freitas, Joao; Pagola, Jorge; Rodriguez-Luna, David; Piñeiro, Socorro; Maisterra, Olga; Rubiera, Marta; Montaner, Joan; Alvarez-Sabin, Jose; Molina, Carlos; Ribo, Marc

    2013-04-01

    Real-time intra-procedure information about ischemic brain damage degree may help physicians in taking decisions about pursuing or not recanalization efforts. We studied gasometric parameters of blood samples drawn through microcatheter in 16 stroke patients who received endovascular reperfusion procedures. After crossing the clot with microcatheter, blood sample was obtained from the middle cerebral artery (MCA) segment distal to occlusion (PostOcc); another sample was obtained from carotid artery (PreOcc). An arterial blood gas (ABG) study was immediately performed. We defined clinical improvement as National Institutes of Health Stroke Scale (NIHSS) decrease of ≥4. The ABG analysis showed differences between PreOcc and PostOcc blood samples in mean oxygen partial pressure (Pre-PaO2: 78.9 ± 16 .3 vs. 73.9 ± 14 .9 mmHg; P  70 mmHg that better predicted further clinical improvement. Patients with Post-PaO2 > 70 mmHg had higher chances of clinical improvement (81.8% vs. 0%; P = .002) and lower disability (median mRS:3 vs. 6; P= .024). In the logistic regression the only independent predictor of clinical improvement was Post-PaO2 > 70 (OR: 5.21 95% CI: 1.38-67.24; P = .013). Direct local blood sampling from ischemic brain is feasible during endovascular procedures in acute stroke patients. A gradient in oxygenation parameters was demonstrated between pre- and post-occlusion blood samples. ABG information may be used to predict clinical outcome and help in decision making in the angio-suite. Copyright © 2011 by the American Society of Neuroimaging.

  12. Flow cytometric comparison of platelets from a whole blood and finger-prick sample: impact of 24 hours storage.

    Science.gov (United States)

    Swanepoel, Albe C; Stander, Andre; Pretorius, Etheresia

    2013-03-01

    In this study, we investigate the validity and laboratory utility of flow cytometry when analyzing platelet activation by studying CD41, CD42b, CD62P and CD63. We compare flow cytometry results from citrated whole-blood and finger-prick samples directly after collection and also after storing both a finger-prick and whole-blood sample for 24 hours. Citrated whole-blood and finger-prick samples were taken from three healthy individuals on two occasions, and a total of 60,000 cells were analyzed for each of the four phycoerythrin-labeled monoclonal antibodies. Half of each sample was analyzed immediately after sampling while the other half was kept in the fridge at 6 °C for 24 hours before analysis. No significant difference was found between the sampling methods or the period of time before analysis. Results therefore suggest that an appropriately prepared finger-prick sample can be used for platelet function analysis, and samples can be stored for 24 hours in the fridge at 6 °C before analysis.

  13. Tissue distribution of psittacid herpesviruses in latently infected parrots, repeated sampling of latently infected parrots and prevalence of latency in parrots submitted for necropsy.

    Science.gov (United States)

    Tomaszewski, Elizabeth K; Wigle, William; Phalen, David N

    2006-11-01

    Psittacid herpesvirus-1 (PsHV-1) is the cause of an acute fatal disease in parrots and is implicated as the cause of papillomatous lesions of the digestive tract. Not all infections cause disease and some parrots are infected asymptomatically. Latently infected parrots are potential sources for virus dissemination. Tissues from parrots that died spontaneously with a history of coming from flocks where a PsHV-1 outbreak had occurred were examined for PsHV-1 DNA. Fourteen of 16 parrots examined were infected with at least 1 variant of PsHV-1; of these 13 (93%) had viral DNA in either or both the oral and cloacal mucosa, suggesting that most latently infected parrots could be detected by sampling these sites. Nine of 9 parrots shown to be infected 5 years prior to this study were positive again on repeat sampling and were infected with the same virus genotype. Opportunistic sampling of parrots submitted for diagnostic necropsy indicated that the prevalence of PsHV-1 in parrots in the sampled population was approximately 9.3%. PsHV-1 genotypes 1, 2, and 3 were found in these birds, but genotype 4 was not. Six necropsy specimens were found to be infected with two PsHV-1 genotypes and it was concluded that infection with one serotype did not protect against infection with another. Psittacid herpesvirus 2 (PsHV-2) was identified in 4 African grey parrots and a blue and gold macaw. Prior to this study PsHV-2 had only been found in African grey parrots.

  14. Racial discrimination associated with higher diastolic blood pressure in a sample of American Indian adults.

    Science.gov (United States)

    Thayer, Zaneta M; Blair, Irene V; Buchwald, Dedra S; Manson, Spero M

    2017-05-01

    Hypertension prevalence is high among American Indians (AIs). AIs experience a substantial burden of interpersonal racial discrimination, which in other populations has been associated with higher blood pressure. The purpose of this study is to understand whether racial discrimination experiences are associated with higher blood pressure in AIs. We used the Everyday Discrimination Scale to evaluate the relationship between discrimination and measured blood pressure among 77 AIs from two reservation communities in the Northern Plains. We used multivariate linear regression to evaluate the association of racial discrimination with systolic and diastolic blood pressure, respectively. Racial discrimination, systolic blood pressure, and diastolic blood pressure were analyzed as continuous variables. All analyses adjusted for sex, waist circumference, age, posttraumatic stress disorder status, and education. We found that 61% of participants experienced discrimination that they attributed to their race or ancestry. Racial discrimination was associated with significantly higher diastolic blood pressure (β = 0.22, SE = 0.09, p = .02), and with a similar non-significant trend toward higher systolic blood pressure (β = 0.25, SE = 0.15, p = .09). The results of this analysis suggest that racial discrimination may contribute to higher diastolic blood pressure within Native communities. These findings highlight one pathway through which the social environment can shape patterns of biology and health in AI and other socially and politically marginalized groups. © 2017 Wiley Periodicals, Inc.

  15. Comparison of a new blood sampling device with the vacuum tube system for plasma and hematological analyses in healthy dogs.

    Science.gov (United States)

    Reynolds, Brice S; Boudet, Karine G; Faucher, Mathieu R; Geffre, Anne; Germain, Claude; Lefebvre, Hervé P

    2008-01-01

    Pediatric devices based on a capillary system may provide an alternative to vacuum tubes for canine blood sampling. The potential advantages are absence of vein collapse, limited blood volume sampled, and improved safety. The aim of this study was to compare routine plasma and hematological variables in seven healthy dogs using both techniques. Five biochemical analytes were measured, and a complete hematological examination and plasma exogenous creatinine clearance test were performed. No clinically relevant difference between the two techniques was observed for any variable or functional test assessed.

  16. The reproducibility of cerebral blood flow with N-isopropyl-p-({sup 123}I) iodoamphetamine by arterial blood sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Kazufumi; Tamura, Kiyohiko [Akita Univ. (Japan). Hospital; Hirano, Hiroko; Oyama, Yoichi; Kobayashi, Mitsuru; Tomura, Noriaki; Watari, Jiro

    1997-12-01

    The reproducibility of cerebral blood flow (CBF) based on the microsphere model with N-isopropyl-p-({sup 123}I) iodoamphetamine (IMP), was evaluated 4.58% (=CV) and was within 9%. The former was calculated from the elementary experiments, the latter was calculated with the CBF of 11 cases. On the clinical conditions, where we selected some astrocytomas of grade III injected ACNU super selectively with Seldinger catheter, and quantified CBF both pre and post ACNU ia by the ROI of 16.2 mm{phi}. On the other hand we have been monitoring the Cross Calibration Factors (CCFs) since we started CBF quantification. The CCFs during 5 years were all within the upper and the lower control limits. At a worst case the average deviation of CCF was 1.17% by a month, which is equal to 7.0% by 6 months. Then SPECT and well counter should be calibrated at least once every 6 months. (author)

  17. The Metabolic Syndrome, Inflammation, and Colorectal Cancer Risk: An Evaluation of Large Panels of Plasma Protein Markers Using Repeated, Prediagnostic Samples

    Directory of Open Access Journals (Sweden)

    Sophia Harlid

    2017-01-01

    Full Text Available Metabolic syndrome (MetS, a set of metabolic risk factors including obesity, dysglycemia, and dyslipidemia, is associated with increased colorectal cancer (CRC risk. A putative biological mechanism is chronic, low-grade inflammation, both a feature of MetS and a CRC risk factor. However, excess body fat also induces a proinflammatory state and increases CRC risk. In order to explore the relationship between MetS, body size, inflammation, and CRC, we studied large panels of inflammatory and cancer biomarkers. We included 138 participants from the Västerbotten Intervention Programme with repeated sampling occasions, 10 years apart. Plasma samples were analyzed for 178 protein markers by proximity extension assay. To identify associations between plasma protein levels and MetS components, linear mixed models were fitted for each protein. Twelve proteins were associated with at least one MetS component, six of which were associated with MetS score. MetS alone was not related to any protein. Instead, BMI displayed by far the strongest associations with the biomarkers. One of the 12 MetS score-related proteins (FGF-21, also associated with BMI, was associated with an increased CRC risk (OR 1.71, 95% CI 1.19–2.47. We conclude that overweight and obesity, acting through both inflammation and other mechanisms, likely explain the MetS-CRC connection.

  18. Impact of land-use on carbon storage as dependent on soil texture: evidence from a desertified dryland using repeated paired sampling design.

    Science.gov (United States)

    Ye, Xuehua; Tang, Shuangli; Cornwell, William K; Gao, Shuqin; Huang, Zhenying; Dong, Ming; Cornelissen, Johannes H C

    2015-03-01

    Desertification resulting from land-use affects large dryland areas around the world, accompanied by carbon loss. However it has been difficult to interpret different land-use contributions to carbon pools owing to confounding factors related to climate, topography, soil texture and other original soil properties. To avoid such confounding effects, a unique systematic and extensive repeated design of paired sampling plots of different land-use types was adopted on Ordos Plateau, N China. The sampling enabled to quantify the effects of the predominant land-use types on carbon storage as dependent on soil texture, and to define the most promising land-use choices for carbon storage, both in grassland on sandy soil and in desert grassland on brown calcareous soil. The results showed that (1) desertification control should be an effective measure to improve the carbon sequestration in sandy grassland, and shrub planting should be better than grass planting; (2) development of man-made grassland should be a good choice to solve the contradictions of ecology and economy in desert grassland; (3) grassland on sandy soil is more vulnerable to soil degradation than desert grassland on brown calcareous soil. The results may be useful for the selection of land-use types, aiming at desertification prevention in drylands. Follow-up studies should directly investigate the role of soil texture on the carbon storage dynamic caused by land-use change. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Blood culture

    Science.gov (United States)

    Culture - blood ... A blood sample is needed . The site where blood will be drawn is first cleaned with an antiseptic such ... organism from the skin getting into (contaminating) the blood sample and causing a false-positive result (see ...

  20. Post mortem concentrations of endogenous gamma hydroxybutyric acid (GHB) and in vitro formation in stored blood and urine samples.

    Science.gov (United States)

    Busardò, Francesco Paolo; Bertol, Elisabetta; Vaiano, Fabio; Baglio, Giovanni; Montana, Angelo; Barbera, Nunziata; Zaami, Simona; Romano, Guido

    2014-10-01

    Gamma-hydroxybutyrate (GHB) is a central nervous system depressant, primarily used as a recreational drug of abuse with numerous names. It has also been involved in various instances of drug-facilitated sexual assault due to its potential incapacitating effects. The first aim of this paper is to measure the post-mortem concentration of endogenous GHB in whole blood and urine samples of 30 GHB free-users, who have been divided according to the post-mortem interval (PMI) in three groups (first group: 24-36h; second group: 37-72h; third group: 73-192h), trying to evaluate the role of PMI in affecting post mortem levels. Second, the Authors have evaluated the new formation of GHB in vitro in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month. The concentrations were measured by GC-MS after liquid-liquid extraction according to the method validated and published by Elliot (For. Sci. Int., 2003). For urine samples, GHB concentrations were creatinine-normalized. In the first group the GHB mean concentration measured after autopsy was: 2.14mg/L (range 0.54-3.21mg/L) in blood and 3.90mg/g (range 0.60-4.81mg/g) in urine; in the second group it was: 5.13mg/L (range 1.11-9.60mg/L) in blood and 3.93mg/g (range 0.91-7.25mg/g) in urine; in the third group it was: 11.8mg/L (range 3.95-24.12mg/L) in blood and 9.83mg/g (range 3.67-21.90mg/g) in urine. The results obtained in blood and urine samples showed a statistically significant difference among groups (pGHB in blood and urine samples. Regarding the new formation of GHB in vitro both in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month, although there was no significant increases of GHB levels throughout the period of investigation, the lowest increases were found both in blood and urine at -20°C, therefore we recommend the latter as optimal storage temperature.

  1. The identification of menstrual blood in forensic samples by logistic regression modeling of miRNA expression.

    Science.gov (United States)

    Hanson, Erin K; Mirza, Mohid; Rekab, Kamel; Ballantyne, Jack

    2014-11-01

    We report the identification of sensitive and specific miRNA biomarkers for menstrual blood, a tissue that might provide probative information in certain specialized instances. We incorporated these biomarkers into qPCR assays and developed a quantitative statistical model using logistic regression that permits the prediction of menstrual blood in a forensic sample with a high, and measurable, degree of accuracy. Using the developed model, we achieved 100% accuracy in determining the body fluid of interest for a set of test samples (i.e. samples not used in model development). The development, and details, of the logistic regression model are described. Testing and evaluation of the finalized logistic regression modeled assay using a small number of samples was carried out to preliminarily estimate the limit of detection (LOD), specificity in admixed samples and expression of the menstrual blood miRNA biomarkers throughout the menstrual cycle (25-28 days). The LOD was blood was identified only during the menses phase of the female reproductive cycle in two donors.

  2. Possible cause of lack of positive samples on homologous blood transfusion.

    Science.gov (United States)

    Krotov, Grigory; Nikitina, Maria; Rodchenkov, Grigory

    2014-01-01

    Homologous blood transfusion is a prohibited method of blood manipulation that can be used to increase the number of erythrocytes circulating in the blood stream resulting in an increased oxygen transport capacity. In doping controls, homologous blood transfusions are determined by means of a procedure based on the detection of red blood cell phenotypes by flow cytometry. In the past six years, no adverse analytical findings concerning homologous blood transfusions were reported. One explanation for that phenomenon, assuming that athletes have not completely given up this kind of manipulation, would be a more careful selection of potential donors. If such a donor has the same set of minor erythrocyte antigens as the recipient, the established methodology to detect homologous transfusion would fail. We have hypothesized that any athlete can be a potential donor for teammates with the same RhD factor and AB0 blood group. Having analyzed the phenotype of erythrocytes of 535 Russian athletes in various endurance sports, several pairs of athletes with the same phenotype were observed. Based on the frequency of occurrence of red blood cell antigens, the theoretical probability of finding a donor within a team with exactly the same phenotype was calculated, and the existing number of occurrences where two individuals share the same phenotype in the same sport was in fact five times higher than the theoretical probability. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Comparison of two real-time PCR assays for the detection of malaria parasites from hemolytic blood samples - Short communication.

    Science.gov (United States)

    Hagen, Ralf Matthias; Hinz, Rebecca; Tannich, Egbert; Frickmann, Hagen

    2015-06-01

    We compared the performance of an in-house and a commercial malaria polymerase chain reaction (PCR) assay using freeze-thawed hemolytic blood samples. A total of 116 freeze-thawed ethylenediamine tetraacetic acid (EDTA) blood samples of patients with suspicion of malaria were analyzed by an in-house as well as by a commercially available real-time PCR. Concordant malaria negative PCR results were reported for 39 samples and malaria-positive PCR results for 67 samples. The in-house assay further detected one case of Plasmodium falciparum infection, which was negative in the commercial assay as well as five cases of P. falciparum malaria and three cases of Plasmodium vivax malaria, which showed sample inhibition in the commercial assay. The commercial malaria assay was positive in spite of a negative in-house PCR result in one case. In all concordant results, cycle threshold values of P. falciparum-positive samples were lower in the commercial PCR than in the in-house assay. Although Ct values of the commercial PCR kit suggest higher sensitivity in case of concordant results, it is prone to inhibition if it is applied to hemolytic freeze-thawed blood samples. The number of misidentifications was, however, identical for both real-time PCR assays.

  4. Dried Blood Spot Proteomics: Surface Extraction of Endogenous Proteins Coupled with Automated Sample Preparation and Mass Spectrometry Analysis

    Science.gov (United States)

    Martin, Nicholas J.; Bunch, Josephine; Cooper, Helen J.

    2013-08-01

    Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.

  5. Linking SNPs to CAG repeat length in Huntington's disease patients.

    Science.gov (United States)

    Liu, Wanzhao; Kennington, Lori A; Rosas, H Diana; Hersch, Steven; Cha, Jang-Ho; Zamore, Phillip D; Aronin, Neil

    2008-11-01

    Allele-specific silencing using small interfering RNAs targeting heterozygous single-nucleotide polymorphisms (SNPs) is a promising therapy for human trinucleotide repeat diseases such as Huntington's disease. Linking SNP identities to the two HTT alleles, normal and disease-causing, is a prerequisite for allele-specific RNA interference. Here we describe a method, SNP linkage by circularization (SLiC), to identify linkage between CAG repeat length and nucleotide identity of heterozygous SNPs using Huntington's disease patient peripheral blood samples.

  6. Using photoluminescent gold nanodots to detect hemoglobin in diluted blood samples.

    Science.gov (United States)

    Chen, Li-Yi; Huang, Chih-Ching; Chen, Wei-Yu; Lin, Han-Jia; Chang, Huan-Tsung

    2013-05-15

    In this study we used photoluminescent 11-mercaptoundecanoic acid-bound gold nanodots (11-MUA-Au NDs) to detect hemoglobin through photoluminescence (PL) quenching. The mechanism of quenching, which occurred through redox reactions between the 11-MUA-Au NDs and the Fe(II) atoms of hemin units, was supported by an increase in the signals (G 2.0 and 5.9) of high-spin state Fe(III) ions. The Stern-Volmer quenching constants (Ksv) for hemin, cytochrome c, hemoglobin, and myoglobin were 5.6×10(7), 1.7×10(7), 1.6×10(7), and 6.2×10(6)M(-1), respectively, in good agreement with the order of their reduction potentials. When excited at 375nm, the PL intensity of the 11-MUA-Au NDs at 520nm decreased upon increasing the concentration of hemoglobin from 1.0 to 10nM (R(2)=0.9913). This approach using bovine serum albumin blocked 11-MUA-Au NDs provided a limit of detection for hemoglobin (at a signal-to-noise ratio of 3) of 0.5nM in biological buffer, with great selectivity over other non-heme-containing proteins, including human serum albumin, β-casein, and carbonic anhydrase. We validated the practicality of this approach through the determination of the concentrations (1.85-2.46mM) of hemoglobin in diluted (10(6)-fold) human blood samples based on PL quenching of Au NDs. This simple, sensitive, and selective approach holds great potential for the diagnosis of several diseases, including anemia, erythrocytosis, and thalassemias. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. A Comparative Study of Blood Culture Sampling from Umbilical Catheter Line versus Peripheral Site

    Directory of Open Access Journals (Sweden)

    Abdolkarim Hamedi

    2010-08-01

    Full Text Available Neonatal sepsis is an important cause of death and morbidity in newborns and is diagnosed by isolation of organism in blood culture. In several reports,reliablity of blood cultures were done from umbi lical catheters,have been demonstrated. The objective of the present study was to determine,wether an inde welling umbilical catheter, could be an alternative site for blood culture. In a prospective study over 6 months during 2006,141 paired blood cultures from 134 infant,were done simultaneously from peripheral site and umbilical catheter (mostly U. V. C,during the first four days of life. Majority of these infants were preterm and admitted to NICU for special care. these infants had indwelling umbilical line and had indication of sepsis workup. A total of 141 pairs of blood cultures were obtained from 134 infants. In 16 infants blood culture pairs were positive for one organism in both peripheral vein and umbilical site. 71. 6% of total cultures (n=11pairs were negative in boths site. A total of 22 pairs were positive in one site only,with 5 positive from peripheral vein only and the other 17 from umblical site. Two pairs were positve in boths site with two different organism. In over all 16 infant (11%of blood were considered to be contaminated. Contamination rate were 2. 4% and 9. 2% for peripheral and umbilical catheter site. Contamination rate increased after 48 hours of age in umbilical catheter. The result showed that after 2 days contamination rate for blood culture taken from catheter line increased and specifity decreased. We recommended that blood culture via umblical catheter in first 2 days in sick neonates with indwelling catheter can be a alternate site of blood culture sampelling.

  8. The relationship between blood and muscle samples to monitor for residues of the antibiotic enrofloxacin in chickens.

    Science.gov (United States)

    Reyes-Herrera, I; Schneider, M J; Blore, P J; Donoghue, D J

    2011-02-01

    In 2005, the US Food and Drug Administration withdrew approval for use of enrofloxacin in poultry, thus effectively imposing zero tolerance for residues of this antibiotic in poultry. Conventional residue monitoring for most antibiotics, including enrofloxacin, involves removing poultry carcasses from the processing line and collecting muscle tissues for analysis. Because of the loss of valuable edible products and the difficulties and expense of sampling all the carcasses, only a small portion of carcasses are tested for violative residues. Unlike muscle tissue, blood is readily available from all birds at the beginning of processing and may be used to screen for illegal residues in all poultry carcasses. It is unknown, however, if enrofloxacin concentrations in blood are predictive of muscle concentrations. In an effort to evaluate this relationship, 156 broiler chickens, 5 wk of age, were dosed with either 25 or 50 µg/mL of enrofloxacin for 3 or 7 d, respectively, in the drinking water. Blood and muscle samples were collected at 0, 1, 3, 6, 12, and 24 h (n = 6 birds/group) during the first dosing day, every 48 h during the dosing period, and every 12 h during the withdrawal period for up to 60 h after withdrawal. Enrofloxacin residues were determined in all blood and tissue samples during the dosing periods and in most of the withdrawal period for both doses. These results support the potential to use blood to screen for illegal enrofloxacin residues in edible poultry tissues in an effort to protect the human food supply.

  9. Dissociation between the time courses of femoral artery blood flow and pulmonary VO2 during repeated bouts of heavy knee extension exercise in humans.

    Science.gov (United States)

    Fukuba, Yoshiyuki; Ohe, Yukie; Miura, Akira; Kitano, Asami; Endo, Masako; Sato, Hironori; Miyachi, Motohiko; Koga, Shunsaku; Fukuda, Osamu

    2004-05-01

    It has frequently been demonstrated that prior heavy cycling exercise facilitates pulmonary O(2) kinetics at the onset of subsequent heavy exercise. This might be due to improved muscle perfusion via acidosis-induced vasodilating effects. However, it is difficult to measure the blood flow (BF) to the working muscles (via the femoral artery) during cycling exercise. We therefore selected supine knee extension (KE) exercise as an alternative, and investigated whether the faster O(2) kinetics in the 2nd bout was matched by proportionally faster BF kinetics to the exercising muscle. Nine healthy subjects (aged 21-44 years) volunteered to participate in this study. The protocol consisted of two consecutive 6-min KE exercise bouts in a supine position (work rate: 70-75% of peak power) separated by a 6-min baseline rest (EX1 to EX2). During the protocol, a pulsed Doppler ultrasound technique was utilized to continuously measure the BF in the right femoral artery. The protocol was repeated at least 6 times to characterize the precise kinetics. In agreement with previous studies using cycling exercise, the O(2) kinetics in the 2nd bout were facilitated compared with that in the 1st bout [mean +/-s.d. of the 'effective' time constant (tau): EX1, 68.6 +/- 15.9, versus EX2, 58.0 +/- 14.4 s. Phase II-tau: EX1, 48.7 +/- 9.0, versus EX2, 41.2 +/- 13.3 s. Empirical index of the slow component (Delta O(2(6-3))): EX1, 78 +/- 44, versus EX2, 57 +/- 36 ml min(-1) (P 0.05)]. It was concluded that the faster pulmonary O(2) kinetics during heavy KE exercise following prior heavy exercise was not associated with a similar modulation in the BF to the working muscles.

  10. Development and validation of an indirect Enzyme-linked immunosorbent assay for the detection of antibodies against Schmallenberg virus in blood samples from ruminants.

    Science.gov (United States)

    van der Heijden, H M J F; Bouwstra, R J; Mars, M H; van der Poel, W H M; Wellenberg, G J; van Maanen, C

    2013-10-01

    To detect Schmallenberg virus (SBV) infections in ruminants and to perform SBV epidemiological studies a cost-effective serological test is required. For these purposes an indirect whole virus Enzyme-linked Immunosorbent Assay (ELISA) for detection of SBV specific antibodies in ruminant blood samples was developed. Schmallenberg virus antigen was produced by propagation on Vero cells, partly purified and coated onto ELISA plates. The indirect ELISA procedure included the subsequent incubation of diluted samples, protein-G-HRP conjugate and TMB substrate solution. Net Optical Densities (OD) values were calculated and expressed as a sample to positive percentage (S/P%) by comparison of the average net OD with the OD of the positive control. Validation of this assay was performed using 633 samples from SBV-free sheep, goats and cattle, and 141 samples from SBV suspect ruminants. The diagnostic specificity was 98.8%. Test results of 86 ruminant serum samples using both the SBV-ELISA and an SBV virus neutralization test (VNT), designated as the gold standard serological test for SBV, showed good correlation: at an S/P cut-off of 15% only one VNT positive sample tested negative in the SBV ELISA. The diagnostic sensitivity of the ELISA, relative to the VNT, was 98.8% (95% CI: 93.3-100.0%). The ELISA showed a high repeatability (cv=6.5%) and reproducibility (100% agreement). It was concluded that this ELISA is a suitable test method for the detection of SBV antibodies in sera from cows, sheep and, possibly, goats.

  11. Potassium but not lactate dehydrogenase elevation due to in vitro hemolysis is higher in capillary than in venous blood samples.

    Science.gov (United States)

    Oostendorp, Marlies; van Solinge, Wouter W; Kemperman, Hans

    2012-10-01

    Elevated potassium concentrations due to in vitro hemolysis can lead to errors in diagnoses and treatment. Recently, we observed that potassium elevation in capillary samples appeared higher than expected, based on hemolytic index (H-index). To investigate the relation between potassium increase and H-index for capillary samples. As a control, the same analysis was performed for lactate dehydrogenase (LDH). Potassium results of 332 760 venous and 2620 capillary samples were selected. For LDH, 135 974 venous and 999 capillary samples were included. Venous and capillary samples were differentiated by using patient age, as we perform mostly capillary blood sampling in children and venous sampling in adults. Results were obtained with Beckman-Coulter DxC800 analyzers. The increase in potassium with increasing H-index was considerably higher for capillary samples than venous samples. Linear regression revealed a potassium increase of 0.38 mEq/L per increment in H-index for capillary samples, whereas a 0.17 mEq/L increase was found for venous samples. For LDH, no differences were found between venous and capillary samples. At identical H-index, capillary samples showed higher potassium elevations than venous samples. A possible explanation is that capillary sampling causes increased leakage of ions, such as potassium, from erythrocytes, compared with proteins such as hemoglobin and LDH. These results are especially important considering the increasing use of whole blood point-of-care analyzers, where the H-index is often not determined. Potassium results should therefore be interpreted with caution to avoid severe misdiagnosis of hypokalemia and hyperkalemia.

  12. Using CF11 cellulose columns to inexpensively and effectively remove human DNA from Plasmodium falciparum-infected whole blood samples

    Directory of Open Access Journals (Sweden)

    Venkatesan Meera

    2012-02-01

    Full Text Available Abstract Background Genome and transcriptome studies of Plasmodium nucleic acids obtained from parasitized whole blood are greatly improved by depletion of human DNA or enrichment of parasite DNA prior to next-generation sequencing and microarray hybridization. The most effective method currently used is a two-step procedure to deplete leukocytes: centrifugation using density gradient media followed by filtration through expensive, commercially available columns. This method is not easily implemented in field studies that collect hundreds of samples and simultaneously process samples for multiple laboratory analyses. Inexpensive syringes, hand-packed with CF11 cellulose powder, were recently shown to improve ex vivo cultivation of Plasmodium vivax obtained from parasitized whole blood. This study was undertaken to determine whether CF11 columns could be adapted to isolate Plasmodium falciparum DNA from parasitized whole blood and achieve current quantity and purity requirements for Illumina sequencing. Methods The CF11 procedure was compared with the current two-step standard of leukocyte depletion using parasitized red blood cells cultured in vitro and parasitized blood obtained ex vivo from Cambodian patients with malaria. Procedural variations in centrifugation and column size were tested, along with a range of blood volumes and parasite densities. Results CF11 filtration reliably produces 500 nanograms of DNA with less than 50% human DNA contamination, which is comparable to that obtained by the two-step method and falls within the current quality control requirements for Illumina sequencing. In addition, a centrifuge-free version of the CF11 filtration method to isolate P. falciparum DNA at remote and minimally equipped field sites in malaria-endemic areas was validated. Conclusions CF11 filtration is a cost-effective, scalable, one-step approach to remove human DNA from P. falciparum-infected whole blood samples.

  13. Epigenome-wide profiling of DNA methylation in paired samples of adipose tissue and blood.

    Science.gov (United States)

    Huang, Yen-Tsung; Chu, Su; Loucks, Eric B; Lin, Chien-Ling; Eaton, Charles B; Buka, Stephen L; Kelsey, Karl T

    2016-03-03

    Many epigenetic association studies have attempted to identify DNA methylation markers in blood that are able to mirror those in target tissues. Although some have suggested potential utility of surrogate epigenetic markers in blood, few studies have collected data to directly compare DNA methylation across tissues from the same individuals. Here, epigenomic data were collected from adipose tissue and blood in 143 subjects using Illumina HumanMethylation450 BeadChip array. The top axis of epigenome-wide variation differentiates adipose tissue from blood, which is confirmed internally using cross-validation and externally with independent data from the two tissues. We identified 1,285 discordant genes and 1,961 concordant genes between blood and adipose tissue. RNA expression data of the two classes of genes show consistent patterns with those observed in DNA methylation. The discordant genes are enriched in biological functions related to immune response, leukocyte activation or differentiation, and blood coagulation. We distinguish the CpG-specific correlation from the within-subject correlation and emphasize that the magnitude of within-subject correlation does not guarantee the utility of surrogate epigenetic markers. The study reinforces the critical role of DNA methylation in regulating gene expression and cellular phenotypes across tissues, and highlights the caveats of using methylation markers in blood to mirror the corresponding profile in the target tissue.

  14. Comparison of loop-mediated isothermal amplification (LAMP) and nested-PCR assay targeting the RE and B1 gene for detection of Toxoplasma gondii in blood samples of children with leukaemia.

    Science.gov (United States)

    Fallahi, Shirzad; Seyyed Tabaei, Seyyed Javad; Pournia, Yadollah; Zebardast, Nozhat; Kazemi, Bahram

    2014-07-01

    Toxoplasmosis diagnosis constitutes an important measure for disease prevention and control. In this paper, a newly described DNA amplification technique, loop-mediated isothermal amplification (LAMP), and nested-PCR targeting the repeated element (RE) and B1 gene, were compared to each other for the detection of Toxoplasma gondii DNA in blood samples of children with leukaemia. One hundred ten blood samples from these patients were analyzed by LAMP and nested-PCR. Out of 50 seropositive samples (IgM+, IgG+), positive results were obtained with 92% and 86% on RE, B1-LAMP and 82% and 68% on RE, B1-nested PCR analyses, respectively. Of the 50 seronegative samples, three, two and one samples were detected positive by RE-LAMP, B1-LAMP and RE-nested PCR assays, respectively, while none were detected positive by B1-nested PCR. None of the 10 IgM-, IgG+ samples was detected positive after testing LAMP and nested-PCR assays in duplicate. This is the first report of a study in which the LAMP method was applied with high sensitivity and efficacy for the diagnosis of T. gonii in blood samples of children with leukaemia.

  15. Adiponectin levels measured in dried blood spot samples from neonates born small and appropriate for gestational age

    DEFF Research Database (Denmark)

    Klamer, A; Skogstrand, Kristin; Hougaard, D M

    2007-01-01

    Adiponectin levels measured in neonatal dried blood spot samples (DBSS) might be affected by both prematurity and being born small for gestational age (SGA). The aim of the study was to measure adiponectin levels in routinely collected neonatal DBSS taken on day 5 (range 3-12) postnatal from...

  16. Adiponectin levels measured in dried blood spot samples from neonates born small and appropriate for gestational age

    DEFF Research Database (Denmark)

    Klamer, A; Skogstrand, Kristin; Hougaard, D M;

    2007-01-01

    Adiponectin levels measured in neonatal dried blood spot samples (DBSS) might be affected by both prematurity and being born small for gestational age (SGA). The aim of the study was to measure adiponectin levels in routinely collected neonatal DBSS taken on day 5 (range 3-12) postnatal from...

  17. Role of therapeutic drug monitoring in pulmonary infections : use and potential for expanded use of dried blood spot samples

    NARCIS (Netherlands)

    Hofman, Susan; Bolhuis, Mathieu S.; Koster, Remco A.; Akkerman, Onno W.; van Assen, Sander; Stove, Christophe; Alffenaar, Jan-Willem C.

    2015-01-01

    Respiratory tract infections are among the most common infections in men. We reviewed literature to document their pharmacological treatments, and the extent to which therapeutic drug monitoring (TDM) is needed during treatment. We subsequently examined potential use of dried blood spots as sample p

  18. Blood oxygen content in microliter samples using an easy-to-build galvanic oxygen cell.

    Science.gov (United States)

    Grubb, B R; Mills, C D

    1981-02-01

    We have designed a simple, inexpensive, easy-to-build and operate apparatus for measuring blood oxygen content. The galvanic oxygen cell (fuel cell) requires as little as 1 microliter of blood and has a measuring time of 1-3 min. It is well suited for measuring oxygen content in fluids low in oxygen inasmuch as the sensitivity of the instrument is variable. Either air or water (at a known temperature and oxygen tension) can be used for calibration. No significant differences in blood oxygen content measured with our cell or the Van Slyke manometric method were found.

  19. Highly sensitive and selective determination of pyrazinamide at poly-L-methionine/reduced graphene oxide modified electrode by differential pulse voltammetry in human blood plasma and urine samples.

    Science.gov (United States)

    Cheemalapati, Srikanth; Devadas, Balamurugan; Chen, Shen-Ming

    2014-03-15

    In this current study we used electrochemically active film which contains poly-L-methionine (PMET) and electrochemically reduced graphene oxide (ERGO) on glassy carbon electrode (GCE) for pyrazinamide (PZM) detection. The electrocatalytic response of analyte at PMET/ERGO/GCE film was measured using both cyclic voltammetry (CV) and differential pulse voltammetry (DPV). In addition, electrochemical impedance studies revealed that the smaller R(ct) value observed at PMET/ERGO film modified GCE which authenticates its good conductivity and faster electron transfer rate. The prepared PMET/ERGO/GCE film exhibits excellent DPV response towards PZM and the reduction peak current increased linearly with respect to PZM concentration in the linear range between 0.4 μM to 1129 μM with a sensitivity of 0.266 μA μM(-1) cm(-2). Real sample studies were carried out in human blood plasma and urine samples, which offered good recovery and revealed the promising practicality of the sensor for PZM detection. The proposed sensor displayed a good selectivity, repeatability, sensitivity with appreciable consistency and good reproducibility. In addition, the proposed electrochemical sensor showed good results towards the commercial pharmaceutical PZM samples.

  20. Effects of Different Blood Sampling Methods on Value of Blood Glucose Measured by Rapid Blood Glucose Meter%采血方法对快速血糖测定仪测量值的影响

    Institute of Scientific and Technical Information of China (English)

    赵东荣

    2015-01-01

    目的:探讨不同采血方法对快速血糖测定仪测量值的影响。方法通过对60例糖尿病患者采用3种不同的采血方法,即自然流出法、热水热敷按摩法和手指挤血法,进行末梢血糖浓度的快速测定,同时利用大型生化分析仪测定其静脉血血糖浓度。结果自然流出法测定血糖值和静脉血糖值比较差异无统计学意义(P>0.05),热水热敷按摩和手指挤血法测定血糖值均显著低于静脉血糖值,差异均有统计学意义(P<0.05)。结论临床上使用快速血糖仪检测血糖值时,为保证结果的准确性,宜采用自然流出法采取末梢血。%ObjectiveTo assess the inlfuence of different methods of blood sampling on the results tested by rapid blood glucose meter.Methods Blood glucose of 60 patients with diabetes were tested by rapid blood glucose meter through 3 different methods of blood sampling, and compared with the value of blood glucose measured by taking glucose oxidation enzyme from venous blood.Results There was no statistical signiifcance in value of blood glucose between natural effusion group and venous blood (P>0.05). The values of blood glucose in hot water massage group and finger squeezing group were remarkably lower than those in venous blood group (P<0.05).Conclusion The natural blood out flow of fingers is the better way when value of blood glucose measured by rapid blood glucose meter in clinic.

  1. Persistent organic pollutants in blood samples of Southern Giant Petrels (Macronectes giganteus) from the South Shetland Islands, Antarctica.

    Science.gov (United States)

    Colabuono, Fernanda I; Vander Pol, Stacy S; Huncik, Kevin M; Taniguchi, Satie; Petry, Maria V; Kucklick, John R; Montone, Rosalinda C

    2016-09-01

    Seabirds play an important role as top consumers in the food web and can be used as biomonitors of exposure to pollutants. Contamination studies involving non-destructive sampling methods are of considerable importance, allowing better evaluation of the levels of pollutants and their toxic effects. In the present study, organohalogen contaminants were analyzed in 113 blood samples from Southern Giant Petrel (Macronectes giganteus) adults and chicks collected in the austral summer of 2011/2012 and 2012/2013 from colonies on Elephant and Livingston Islands, South Shetland, Antarctica. Polychlorinated biphenyls (PCBs), hexachlorobenzene (HCB), pentachlorobenzene (PeCB), mirex, dichlorodiphenyltrichloroetane and derivatives (DDTs) and chlordanes were detected in all birds, whereas polybrominated diphenyl ethers (PBDEs) were not detected in any blood samples. No significant differences were found in organochlorine levels between sampling events. Adults exhibited significantly higher levels than chicks, except for PeCB. PCBs, HCB, mirex and DDTs were statistically similar in males and females from Elephant Island. Females on Livingston Island exhibited higher HCB values than males, but no sex differences were found regarding other organochlorines. The similarity in organochlorine levels between sexes in birds with very marked sexual segregation in feeding habits during the breeding season may indicate that significant amounts of contaminants are acquired during migration to lower latitudes, when the diets of males and females are similar. Birds sampled on Livingston Island exhibited significantly lower levels of PCBs, HCB, DDTs, mirex and chlordanes in comparison to those on Elephant Island, which could be the result of distinct foraging patterns between the two colonies. Organochlorine levels were similar between years in birds captured in two consecutive breeding seasons. Blood samples from Southern Giant Petrels adults and chicks proved to be useful for the comparison

  2. A simple and reliable method to blood type monkeys using serum samples.

    Science.gov (United States)

    Chen, Song; Wei, Qing; Li, Junhua; Xiang, Ying; Guo, Hui; Ichim, Thomas E; Chen, Shi; Chen, Gang

    2009-10-01

    Monkeys are frequently used in experimental transplantation research because of their physical traits and availability. As ABO incompatibility may result in humoral injury, it is important to identify the ABO blood typing of monkeys before transplantation. However, monkeys lack expression of ABH antigens on red blood cells, which makes accurate determination of the blood type difficult. The gel agglutination assay has been widely used as a routine blood grouping test clinically for more than 10 years. In this study, we evaluated the efficacy and the interference factors of using the gel system (including the direct gel system and the reverse gel system) for ABO typing in rhesus monkeys (n = 38) and cynomolgus monkeys (n = 26). Immunohistochemistry assay was used to obtain the accurate blood type data of monkeys. The results revealed that the direct gel system was ineffective in blood typing of monkeys, whereas the reverse gel system assay, which is based on preabsorbed serum, provided reproducible results that were confirmed by histologic analysis. We conclude that the reverse gel system assay with use of preabsorbed serum is a simple and reliable method for ABO typing of monkeys.

  3. Effects of music therapy on pain responses induced by blood sampling in premature infants: A randomized cross-over trial

    Science.gov (United States)

    Shabani, Fidan; Nayeri, Nahid Dehghan; Karimi, Roghiyeh; Zarei, Khadijeh; Chehrazi, Mohammad

    2016-01-01

    Background: Premature infants are subjected to many painful procedures during care and treatment. The aim of this study was to assess the effect of music therapy on physiological and behavioral pain responses of premature infants during and after blood sampling. Materials and Methods: This study was a cross-over clinical trial conducted on 20 infants in a hospital affiliated to Tehran University of Medical Sciences for a 5-month period in 2011. In the experimental group, Transitions music was played from 5 min before until 10 min after blood sampling. The infants’ facial expressions and physiological measures were recorded from 10 min before until 10 min after sampling. All steps and measurements, except music therapy, were the same for the control group. Data were analyzed using SAS and SPSS software through analysis of variance (ANOVA) and Chi-square tests. Results: There were significant differences between the experimental and control groups (P = 0.022) in terms of heart rate during needle extraction and at the first 5 min after sampling (P = 0.005). Considering the infant's sleep–wake state in the second 5 min before sampling, the statistical difference was significant (P = 0.044). Difference was significant (P = 0.045) during injection of the needle, in the first 5 min after sampling (P = 0.002), and in the second 5 min after sampling (P = 0.005). There were significant difference in infants’ facial expressions of pain in the first 5 min after sampling (P = 0.001). Conclusions: Music therapy reduces the physiological and behavioral responses of pain during and after blood sampling. PMID:27563323

  4. Enhanced Stability of Blood Matrices Using a Dried Sample Spot Assay to Measure Human Butyrylcholinesterase Activity and Nerve Agent Adducts

    Science.gov (United States)

    Perez, Jonas W.; Pantazides, Brooke G.; Watson, Caroline M.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    Dried matrix spots are safer to handle and easier to store than wet blood products, but factors such as intra-spot variability and unknown sample volumes have limited their appeal as a sampling format for quantitative analyses. In this work, we introduce a dried spot activity assay for quantifying butyrylcholinesterase (BChE) specific activity which is BChE activity normalized to the total protein content in a sample spot. The method was demonstrated with blood, serum, and plasma spotted on specimen collection devices (cards) which were extracted to measure total protein and BChE activity using a modified Ellman assay. Activity recovered from dried spots was ∼80% of the initial spotted activity for blood and >90% for plasma and serum. Measuring total protein in the sample and calculating specific activity substantially improved quantification and reduced intra-spot variability. Analyte stability of nerve agent adducts was also evaluated, and the results obtained via BChE-specific activity measurements were confirmed by quantification of BChE adducts using a previously established LC-MS/MS method. The spotted samples were up to 10-times more resistant to degradation compared to unspotted control samples when measuring BChE inhibition by the nerve agents sarin and VX. Using this method, both BChE activity and adducts can be accurately measured from a dried sample spot. This use of a dried sample spot with normalization to total protein is robust, demonstrates decreased intra-spot variability without the need to control for initial sample volume, and enhances analyte stability. PMID:25955132

  5. [A case-control study of factors associated with repeat teen pregnancy based on a sample from a university maternity hospital].

    Science.gov (United States)

    Silva, Andréa de Albuquerque Arruda; Coutinho, Isabela C; Katz, Leila; Souza, Alex Sandro Rolland

    2013-03-01

    Repeat teen pregnancy is a frequent issue and is considered an aggravating factor for increased maternal and fetal morbidity and social problems. The aim of the study was to identify factors associated with repeat teen pregnancy. A case-control study was conducted in 90 postpartum adolescents with more than one pregnancy (cases) and 90 adult women with a history of only one pregnancy during adolescence (controls). Statistical analysis used hierarchical logistic regression with 5% significance. Early sexual initiation (< 15 years), early age at first pregnancy (< 16 years), not raising the children themselves, and low family income (< one minimum wage) were associated with repeat teenage pregnancy, while partner change was inversely associated. Repeat teen pregnancy was mainly associated with reproductive and socioeconomic factors. Partner change appeared as a protective factor. Measures should be adopted during the postpartum period of teenage mothers in order to avoid repeat pregnancy.

  6. Virological surveillance of dengue in Saint Martin and Saint Barthelemy, French West Indies, using blood samples on filter paper.

    Science.gov (United States)

    Matheus, Séverine; Chappert, Jean-Loup; Cassadou, Sylvie; Berger, Franck; Labeau, Bhetty; Bremand, Laetitia; Winicki, Alain; Huc-Anais, Patricia; Quenel, Philippe; Dussart, Philippe

    2012-01-01

    To strengthen active dengue surveillance in Saint Martin and Saint Barthélemy, two French Caribbean islands, we evaluated the epidemiological usefulness of collecting blood samples from NS1-positive dengue patients on filter paper to identify the dengue serotypes circulating in these regions during a 27-month period. This approach allowed dengue serotypes to be identified by reverse transcriptase-polymerase chain reaction in 90.1% of the total set of 666 samples analyzed and, in 95.5% of the samples collected during the acute phase of the disease. This prospective virological surveillance using blood samples absorbed onto filter paper, which were stored at 4°C and shipped at ambient temperature to a specialized laboratory for analysis, allowed us to avoid the logistic and financial costs associated with shipping frozen venous blood samples. This surveillance system offers a low-cost alternative for reinforcing dengue prevention in areas where specialized laboratories do not exist, notably by facilitating the early detection of potentially new dengue serotypes.

  7. Whole blood samples for adrenocorticotrophic hormone measurement can be stored at room temperature for 4 hours

    DEFF Research Database (Denmark)

    Christensen, Mette; Madsen, Rikke Fogt; Møller, Line Rosengreen

    2016-01-01

    INTRODUCTION: The aim of this study was to investigate and compare the stability of adrenocorticotrophic hormone (ACTH) in whole blood stored on ice and at room temperature for up to 48 hours. This study differs from previous studies by a larger data material. MATERIALS AND METHODS: EDTA......-blood samples from 30 patients were collected, aliquoted and stored on ice or at room temperature for 0, 2, 4, 24, or 48 h before centrifugation, and the plasma was stored frozen until analysis. All samples were analyzed using an automated electrochemiluminescence immunoassay on cobas 6000 e601. The change...... in ACTH concentration was illustrated as ACTH recovery compared to standard conditions defined as samples stored immediately on ice, centrifuged and plasma frozen within 1 h. A change in ACTH concentration of more than 10% was considered to be of clinical relevance. RESULTS: The results showed...

  8. [Use of C-arm CT for improving the hit rate for selective blood sampling from adrenal veins].

    Science.gov (United States)

    Georgiades, C; Kharlip, J; Valdeig, S; Wacker, F K; Hong, K

    2009-09-01

    Primary hyperaldosteronism is the most common curable cause of hypertension with a prevalence of up to 12% among patients with hypertension. Selective blood sampling from adrenal veins is considered the diagnostic gold standard. However, it is underutilized due to the high technical failure rate. The use of C-arm CT during the sampling procedure can reduce or even eliminate this failure rate. If adrenal vein sampling is augmented by native C-arm CT to check for the correct catheter position, the technical success rate increases substantially. General use of this technique will result in correct diagnosis and treatment for patients with primary hyperaldosteronism.

  9. EtG and EtS in Autopsy Blood Samples With and Without Putrefaction Using UPLC-MS-MS.

    Science.gov (United States)

    Hegstad, Solfrid; Kristoffersen, Lena; Liane, Veronica H; Spigset, Olav

    2017-03-01

    Analytical challenges related to postmortem specimens are well known. The degree of putrefaction of the corpse will influence the quality of the blood samples, and both the efficiency of sample preparation and the subsequent chromatographic performance can be affected. An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method was developed and validated for the determination of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in postmortem whole blood. Sample preparation prior to UPLC-MS-MS analysis consisted of protein precipitation and filtration through a phospholipid removal plate. Chromatography was achieved using an HSS T3 column and gradient elution with formic acid in water in combination with methanol. The injection volume was 0.5 µL. Negative electrospray ionization was performed in the multiple reaction monitoring mode. Two transitions were monitored for the analytes and one for the internal standards. The between-assay relative standard deviations were in the range of 1.7-7.0% and the limits of quantification were 0.025 and 0.009 mg/L for EtG and EtS, respectively. Recovery was 51-55% and matrix effects ranged from 98% to 106% (corrected with internal standard). Blood samples from nine autopsy cases with various extents of putrefaction were analyzed. The sample preparation efficiently removed the phospholipids from the blood specimens. The samples were clean and the analytical quality of the chromatographic performance was satisfactory for both analytes irrespective of the degree of putrefaction.

  10. Evaluation and Optimization of Blood Micro-Sampling Methods: Serial Sampling in a Cross-Over Design from an Individual Mouse.

    Science.gov (United States)

    Patel, Nita J; Wickremsinhe, Enaksha; Hui, Yu-Hua; Barr, Alexandar; Masterson, Nicholas; Ruterbories, Kenneth; Weller, Jennifer; Hanes, Jennifer; Kern, Tom; Perkins, Everett

    Current practices applied to mouse pharmacokinetic (PK) studies often use large numbers of animals with sporadic or composite sampling that inadequately describe PK profiles.  The purpose of this work was to evaluate and optimize blood microsampling techniques coupled with dried blood spot (DBS) and LC-MS/MS analysis to generate reliable PK data in mice.  In addition, the feasibility of cross-over designs was assessed and recommendations are presented. The work describes a comprehensive evaluation of five blood microsampling techniques (tail clip, tail vein with needle hub, submandibular, retro-orbital, and saphenous bleeding) in CD-1 mice.  The feasibility of blood sampling was evaluated based on animal observations, ease of bleeding, and ability to collect serial samples.  Methotrexate, gemfibrozil and glipizide were used as test compounds and were dosed either orally or intravenously, followed by DBS collection and LC-MS/MS analysis to compare PK with various bleeding methods. Submandibular and retro-orbital methods that required non-serial blood collections did not allow for inter-animal variability assessments and resulted in poorly described absorption and distribution kinetics.  The submandibular and tail vein with needle-hub methods were the least favorable from a technical feasibility perspective.  Serial bleeding was possible with cannulated animals or saphenous bleeding in non-cannulated animals.   Of the methods that allowed serial sampling, the saphenous method when executed as described in this report, was most practical, reproducible and provided for assessment of inter-animal variability.  It enabled the collection of complete exposure profiles from a single mouse and the conduct of an intravenous/oral cross-over study design.  This methodology can be used routinely, it promotes the 3Rs principles by achieving reductions in the number of animals used, decreased restraints and animal stress, and improved the quality of data obtained in mouse

  11. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Science.gov (United States)

    Tipple, Craig; Jones, Rachael; McClure, Myra; Taylor, Graham

    2015-02-01

    Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum), is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene) and RNA (16S rRNA) quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53). The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84). From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56) after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  12. [Evaluation of serum iron in hemodialysis patients and its variation due to the difference of blood sampling time].

    Science.gov (United States)

    Matsumoto, Yasutoshi; Ozawa, Yasuaki; Imafuku, Yuji; Yoshida, Hiroshi

    2011-11-01

    Diurnal variations in serum iron concentration were examined to investigate the influence of sampling time in hemodialysis (HD) patients and healthy subjects. The serum iron concentration and TIBC of HD patients decreased significantly (pserum ferritin concentration of HD patients increased significantly (piron transport system: under such condition intracellural iron transition out into peripheral blood stream is low in HD patients. Serum iron concentration in samples collected in the evening decreased significantly both in HD patients (pserum iron concentration reveal almost similar decrement in both groups. In HD patients, serum iron concentration of the blood samples collected on the third day morning after HD and second day morning after HD was examined to see the influence from changes of circulating plasma volume. The serum iron concentration and Hct value in the second day sampling increased significantly compared to the third day sampling (pserum iron concentration corrected by Hct in the second day sampling increased significantly (pserum iron concentration vary in sampling time in HD patients as well as in healthy subjects. We also deduct that there may be other factors concerning changes in circulating plasma volume.

  13. Repeat Minimally Invasive Mitral Valve Replacement for Recurrent Mitral Stenosis after OMC in Patients Who Decline Blood Product Transfusion for Religious Reasons.

    Science.gov (United States)

    Ito, Yujiro; Nakamura, Yoshitsugu; Tagusari, Osamu; Yoshida, Shigehiko

    2015-01-01

    Cardiac surgery for Jehovah's Witness (JW) patients is considered to be high risk because of patients' refusal to receive blood transfusion. We report a successful mitral valve replacement for recurrent mitral stenosis after OMC with minimally invasive right thoracotomy, without any transfusion of allogeneic blood or blood products. This minimally invasive mitral valve replacement through right thoracotomy was an excellent approach for JW patients.

  14. Maintenance of Sensitivity of the T-SPOT.TB Assay after Overnight Storage of Blood Samples, Dar es Salaam, Tanzania.

    Science.gov (United States)

    Talbot, Elizabeth A; Maro, Isaac; Ferguson, Katherine; Adams, Lisa V; Mtei, Lillian; Matee, Mecky; von Reyn, C Fordham

    2012-01-01

    Background. T-SPOT.TB is an interferon gamma release assay for detecting Mycobacterium tuberculosis infection. The requirement to process within 8 hours is constraining, deters use, and leads to invalid results. Addition of T Cell Xtend reagent may allow delayed processing, but has not been extensively field tested. Design. Consecutive AFB smear positive adult tuberculosis patients were prospectively recruited in Dar es Salaam, Tanzania. Patients provided a medical history, 1-3 sputum samples for culture and 1 blood sample which was transported to the laboratory under temperature-controlled conditions. After overnight storage, 25 μL of T Cell Xtend reagent was added per mL of blood, and the sample was tested using T-SPOT.TB. Results. 143 patients were enrolled: 57 patients were excluded because temperature control was not maintained, 19 patients were excluded due to red blood cell contamination, and one did not provide a sputum sample for culture. Among 66 evaluable patients, overall agreement between T-SPOT.TB and culture was 95.4% (95%CI; 87.1-99.0%) with Kappa value 0.548. Sensitivity of T-SPOT.TB when using T Cell Xtend reagent was 96.8% (95%CI; 88.8-99.6%). Conclusions. When T Cell Xtend reagent is added to specimens held overnight at recommended temperatures, T-SPOT.TB is as sensitive as the standard assay in patients with tuberculosis.

  15. Repeated Prolonged Exercise Decreases Maximal Fat Oxidation in Older Men

    DEFF Research Database (Denmark)

    Morville, Thomas; Rosenkilde, Mads; Munch-Andersen, Thor

    2017-01-01

    INTRODUCTION/PURPOSE: Fat metabolism and muscle adaptation was investigated in 6 older trained men (age: 61 ± 4 years; VO2max: 48 ± 2 mL kg min) following repeated prolonged exercise). METHODS: 2706 km (1,681 miles) cycling was performed over 14 days and a blood sample and a muscle biopsy were...

  16. Investigation of endogenous blood lipids components that contribute to matrix effects in dried blood spot samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ismaiel, Omnia A; Jenkins, Rand G; Karnes, H Thomas

    2013-08-01

    Dried blood spot (DBS) sampling coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a rapidly developing approach in the field of biopharmaceutical analysis. DBS sampling enables analysis of small sample volumes with high sensitivity and selectivity while providing a convenient easy to store and ship format. Lipid components that may be extracted during biological sample processing may result in matrix ionization effects and can significantly affect the precision and accuracy of the results. Glycerophosphocholines (GPChos), cholesterols and triacylglycerols (TAG) are the main lipid components that contribute to matrix effects in LC-MS/MS. Various organic solvents such as methanol, acetonitrile, methyl tertiary butyl ether, ethyl ether, dichloromethane and n-hexane were investigated for elution of these lipid components from DBS samples. Methanol extracts demonstrated the highest levels of GPChos whereas ethyl ether and n-hexane extracts contained less than 1.0 % of the GPChos levels in the methanol extracts. Ethyl ether extracts contained the highest levels of cholesterols and TAG in comparison to other investigated organic solvents. Acetonitrile is recommended as an elution solvent due to low lipid recoveries. Matrix effects resulted from different extracted lipid components should be studied and assessed carefully in DBS samples.

  17. Diagnosis of Cerebral Toxoplasmosis in AIDS Patients in Brazil: Importance of Molecular and Immunological Methods Using Peripheral Blood Samples

    Science.gov (United States)

    Colombo, Fabio A.; Vidal, José E.; Oliveira, Augusto C. Penalva de; Hernandez, Adrián V.; Bonasser-Filho, Francisco; Nogueira, Roberta S.; Focaccia, Roberto; Pereira-Chioccola, Vera Lucia

    2005-01-01

    Cerebral toxoplasmosis is the most common cerebral focal lesion in AIDS and still accounts for high morbidity and mortality in Brazil. Its occurrence is more frequent in patients with low CD4+ T-cell counts. It is directly related to the prevalence of anti-Toxoplasma gondii antibodies in the population. Therefore, it is important to evaluate sensitive, less invasive, and rapid diagnostic tests. We evaluated the value of PCR using peripheral blood samples on the diagnosis of cerebral toxoplasmosis and whether its association with immunological assays can contribute to a timely diagnosis. We prospectively analyzed blood samples from 192 AIDS patients divided into two groups. The first group was composed of samples from 64 patients with cerebral toxoplasmosis diagnosed by clinical and radiological features. The second group was composed of samples from 128 patients with other opportunistic diseases. Blood collection from patients with cerebral toxoplasmosis was done before or on the third day of anti-toxoplasma therapy. PCR for T. gondii, indirect immunofluorescence, enzyme-linked immunosorbent assay, and an avidity test for toxoplasmosis were performed on all samples. The PCR sensitivity and specificity for diagnosis of cerebral toxoplasmosis in blood were 80% and 98%, respectively. Patients with cerebral toxoplasmosis (89%) presented higher titers of anti-T. gondii IgG antibodies than patients with other diseases (57%) (P < 0.001). These findings suggest the clinical value of the use of both PCR and high titers of anti-T. gondii IgG antibodies for the diagnosis of cerebral toxoplasmosis. This strategy may prevent more invasive approaches. PMID:16207959

  18. Detection of Chlamydia trachomatis in blood samples as a diagnostic method for complicated and persistent forms of urogenital chlamydia infections

    Directory of Open Access Journals (Sweden)

    Sultanakhmedov E.S.

    2015-09-01

    Full Text Available Goal: the study of the effectiveness of the method for laboratory diagnostics of urogenital chlamydial infection in patients with chronic form of the disease. Material and methods. The presence of DNAof C. trachomatis was detected by PCR in either genital or extragenital (blood sites in eighth patients (four men and four women. Results. It is established that in biological material taken from extragenital (blood sites, C. trachomatis was detected in all patients examined (in 100% of cases, while in clinical samples obtained from genital sites, in seven patients only (87.5%. Conclusion. We found that specific chlamydial DNAcan be detected in extragenital (blood site, despite the negative reaction in the clinical material from the genital tract of patients with genital chlamydial infection.

  19. pH adjustment of human blood plasma prior to bioanalytical sample preparation

    NARCIS (Netherlands)

    Hendriks, G.; Uges, D. R. A.; Franke, J. P.

    2008-01-01

    pH adjustment in bioanalytical sample preparation concerning ionisable compounds is one of the most common sample treatments. This is often done by mixing an aliquot of the sample with a proper buffer adjusted to the proposed pH. The pH of the resulting mixture however, does not necessarily have to

  20. Direct analysis of site-specific N-glycopeptides of serological proteins in dried blood spot samples.

    Science.gov (United States)

    Choi, Na Young; Hwang, Heeyoun; Ji, Eun Sun; Park, Gun Wook; Lee, Ju Yeon; Lee, Hyun Kyoung; Kim, Jin Young; Yoo, Jong Shin

    2017-08-01

    Dried blood spot (DBS) samples have a number of advantages, especially with respect to ease of collection, transportation, and storage and to reduce biohazard risk. N-glycosylation is a major post-translational modification of proteins in human blood that is related to a variety of biological functions, including metastasis, cell-cell interactions, inflammation, and immunization. Here, we directly analyzed tryptic N-glycopeptides from glycoproteins in DBS samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without centrifugation of blood samples, depletion of major proteins, desalting of tryptic peptides, and enrichment of N-glycopeptides. Using this simple method, we identified a total of 41 site-specific N-glycopeptides from 16 glycoproteins in the DBS samples, from immunoglobulin gamma 1 (IgG-1, 10 mg/mL) down to complement component C7 (50 μg/mL). Of these, 32 N-glycopeptides from 14 glycoproteins were consistently quantified over 180 days stored at room temperature. The major abundant glycoproteins in the DBS samples were IgG-1 and IgG-2, which contain nine asialo-fucosylated complex types of 16 different N-glycopeptide isoforms. Sialo-non-fucosylated complex types were primarily detected in the other glycoproteins such as alpha-1-acid glycoprotein 1, 2, alpha-1-antitypsin, alpha-2-macroglobulin, haptoglobin, hemopexin, Ig alpha 1, 2 chain C region, kininogen-1, prothrombin, and serotransferrin. We first report the characterization of site-specific N-glycoproteins in DBS samples by LC-MS/MS with minimal sample preparation.

  1. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, S

    2015-02-01

    Full Text Available and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow as well as color-based segmentation of the different fluids using a hue...

  2. A simplified method for determination of radioactive iron in whole-blood samples

    DEFF Research Database (Denmark)

    Bukhave, Klaus; Sørensen, Anne Dorthe; Hansen, M.

    2001-01-01

    For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method for simultane...... a sensitive method for studying the intestinal absorption of Fe-55 and Fe-59 in man and at the same time allows estimation of the amount of radioiron Located in the vascular compartment.......For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method...... for simultaneous determination of Fe-55 and Fe-59 in blood, using a dry-ashing procedure and recrystallization of the remaining iron. The detection Limit of the method permits measurements of 0.1 Bq/ml blood thus allowing detection of Less than 1% absorption from a 40 kBq dose, which is ethically acceptable...

  3. Large-scale prospective T cell function assays in shipped, unfrozen blood samples

    DEFF Research Database (Denmark)

    Hadley, David; Cheung, Roy K; Becker, Dorothy J

    2014-01-01

    around the timing of infant vaccinations. This assay platform and shipping protocol satisfy the criteria for robust and reproducible long-term measurements of human T cell function, comparable to those of established blood biochemical tests. We present a stable technology for prospective disease......-relevant T cell analysis in immunological diseases, vaccination medicine, and measurement of herd immunity....

  4. A one-step extraction procedure for the screening of cocaine, amphetamines and cannabinoids in postmortem blood samples.

    Science.gov (United States)

    Pelição, Fabrício Souza; Peres, Mariana Dadalto; Pissinate, Jauber Fornaciari; De Martinis, Bruno Spinosa

    2014-01-01

    A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure.

  5. Evaluation of carbon monoxide in blood samples from the second health and nutrition survey. Progress report No. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radford, E.P.

    1976-01-01

    This is a study of carbon monoxide (CO) in the blood of human subjects participating in the Second National Health and Nutrition Survey (HANES II), a detailed study of health indicators in sample populations of many communities throughout the U.S. The purpose of this aspect of the survey is to evaluate the levels of blood carboxyhemoglobin in normal individuals of all ages in typical U.S. communities, from whom accurate histories and clinical studies are available. This report gives results of the first of three years of analyses. A careful calibration of the analytical method has been completed, and more than 3000 blood samples have been analyzed. Although smoking histories are not yet available to permit evaluation of carboxyhemoglobin in non-smokers, in children under 12 years of age, blood COHb has been found to be consistently low, with less than 3% greater than 1.5% COHb. These preliminary results suggest that urban exposure to carbon monoxide among the general population is not now significant in the U.S., at least during the period of these early examinations.

  6. Pattern recognition of monocyte chemoattractant protein-1 (MCP-1) in whole blood samples using new platforms based on nanostructured materials

    Science.gov (United States)

    Stefan-van Staden, Raluca-Ioana; Gugoasa, Livia Alexandra; Biris, Alexandru Radu

    2015-09-01

    Four stochastic microsensors based on nanostructured materials (graphene, maltodextrin (MD), and diamond) integrated in miniaturized platforms were proposed. Monocyte chemoattractant protein-1 (MCP-1) is a pro-inflammatory cytokine whose main function is to regulate cell trafficking. It is correlated with the incidence of cardiovascular diseases and obesity, and was used as the model analyte in this study. The screening of whole blood samples for MCP-1 can be done for concentrations ranging from 10-12 to 10-8 g mL-1. The method was used for both qualitative and quantitative assessments of MCP-1 in whole blood samples. The lowest quantification limits for the assay of MCP-1 (1 pg mL-1) were reached when the microsensors based on protoporphyrin IX/Graphene-Au-3 and on MD/Graphene were employed in the platform design.

  7. Detection and analysis of 12 heavy metals in blood and hair sample from a general population of Pearl River Delta area.

    Science.gov (United States)

    Li, Jiqiang; Cen, Dongzhi; Huang, Donglan; Li, Xufeng; Xu, Jiajun; Fu, Shilin; Cai, Rui; Wu, Xiaocong; Tang, Ming; Sun, Yao; Zhang, Jiren; Zheng, Jingfen

    2014-12-01

    To detect the content of 12 heavy metals in blood and hair sample from a general population of Pearl River Delta area, and to analyze the influence of duration of residence, gender, age, smoking and drinking on the heavy metal content. Use inductively coupled plasma mass spectrometry to detect the content of 12 heavy metals lead (Pb), mercury (Hg), cadmium (Cd), aluminum (Al), arsenic (As), copper (Cu), chrome (Cr), manganese (Mn), nickel (Ni), zinc (Zn), tin (Sn) and antimony (Sb) in blood and hair samples of a total of 50 subjects from a general population, collected by multistage stratified cluster random sampling method. The geometric mean of heavy metal content in blood samples of general population (μg/L): blood aluminum 214.00; blood chrome 92.82; blood manganese 21.43; blood nickel 20.59; blood copper 0.67; blood zinc 11.50; blood arsenic 0.55; blood cadmium 2.45; blood tin 0.00; blood antimony 1.92; blood lead 158.84; and blood mercury 1.19. The geometric mean of heavy metal content in hair samples of general population (μg/g): hair aluminum is 84.65; hair chrome 0.00; hair manganese 2.44; hair nickel 0.61; hair copper 28.49; hair zinc 136.65; hair arsenic 0.75; hair cadmium 0.46; hair tin 1.04; hair antimony 0.05; hair lead 8.97; and hair mercury 0.69. Some heavy metals were correlated with duration of residence, gender, age, smoking and drinking. This was the first time that simultaneously detecting heavy metal content in blood and hair was used to analyze the internal heavy metal burden in resident population of Pearl River Delta area. These data can serve as reference for further research.

  8. Delay in blood sampling for routine newborn screening is associated with increased risk of schizophrenia

    DEFF Research Database (Denmark)

    Nordentoft, Merete; Tidselbak Larsen, Janne; Pedersen, Carsten Bøcker

    2015-01-01

    admission, and parental education and income, the estimates were slightly different. Thus, blood collection at 0-4days was associated with an IRR of 1.27 (95% CI 0.94-1.71), 6-9days 1.31 (95% CI 0.94-1.84) and 10+days 3.52 (95% CI 1.50 to 8.24). DISCUSSION: After adjusting risk estimates for well-known risk...

  9. Systemic Metabolomic Changes in Blood Samples of Lung Cancer Patients Identified by Gas Chromatography Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Suzanne Miyamoto

    2015-04-01

    Full Text Available Lung cancer is a leading cause of cancer deaths worldwide. Metabolic alterations in tumor cells coupled with systemic indicators of the host response to tumor development have the potential to yield blood profiles with clinical utility for diagnosis and monitoring of treatment. We report results from two separate studies using gas chromatography time-of-flight mass spectrometry (GC-TOF MS to profile metabolites in human blood samples that significantly differ from non-small cell lung cancer (NSCLC adenocarcinoma and other lung cancer cases. Metabolomic analysis of blood samples from the two studies yielded a total of 437 metabolites, of which 148 were identified as known compounds and 289 identified as unknown compounds. Differential analysis identified 15 known metabolites in one study and 18 in a second study that were statistically different (p-values <0.05. Levels of maltose, palmitic acid, glycerol, ethanolamine, glutamic acid, and lactic acid were increased in cancer samples while amino acids tryptophan, lysine and histidine decreased. Many of the metabolites were found to be significantly different in both studies, suggesting that metabolomics appears to be robust enough to find systemic changes from lung cancer, thus showing the potential of this type of analysis for lung cancer detection.

  10. Evaluation of dried blood spots as sample matrix for gas chromatography/mass spectrometry based metabolomic profiling.

    Science.gov (United States)

    Kong, Sing Teang; Lin, Hai-Shu; Ching, Jianhong; Ho, Paul C

    2011-06-01

    We propose using dried blood spots (DBS) as sample matrix for gas chromatography/mass spectrometry (GC/MS) based metabolomic profiling for the benefits of higher sample stability, more convenient sample acquisition with DBS, higher analyte separation power, and more readily biomarker identification with GC/MS. To establish this proposition, the metabolomic profiles generated from DBS were compared with that obtained from the conventional whole blood and plasma matrixes and also with dried plasma spots (DPS) as another covariate control. Our findings indicated that whole blood produced the most number of detectable markers (866), whereas DPS yielded the least number (614). DBS and plasma matrix, on the other hand, produced the most similar numbers of detectable (695 vs 749) and identifiable markers (137 vs 147, matching with Fiehn library). From the analysis of the DBS and plasma metabolomic profiles, it was concluded that when l-lysine 2, iminodiacetic acid 2, dl-threo-beta-hydroxyaspartic acid, citric acid, or adenosine-5-monophosphate 2 are not involved as markers, DBS could be a suitable substitute for plasma for metabolomic profiling.

  11. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  12. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay

    DEFF Research Database (Denmark)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana

    2015-01-01

    differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate...

  13. Time and temperature affect glycolysis in blood samples regardless of fluoride-based preservatives: a potential underestimation of diabetes.

    Science.gov (United States)

    Stapleton, Mary; Daly, Niamh; O'Kelly, Ruth; Turner, Michael J

    2017-01-01

    Background The inhibition of glycolysis prior to glucose measurement is an important consideration when interpreting glucose tolerance tests. This is particularly important in gestational diabetes mellitus where prompt diagnosis and treatment is essential. A study was planned to investigate the effect of preservatives and temperature on glycolysis. Methods Blood samples for glucose were obtained from consented females. Lithium heparin and fluoride-EDTA samples transported rapidly in ice slurry to the laboratory were analysed for glucose concentration and then held either in ice slurry or at room temperature for varying time intervals. Paired fluoride-citrate samples were received at room temperature and held at room temperature, with analysis at similar time intervals. Results No significant difference was noted between mean glucose concentrations when comparing different sample types received in ice slurry. The mean glucose concentrations decreased significantly for both sets of samples when held at room temperature (0.4 mmol/L) and in ice slurry (0.2 mmol/L). A review of patient glucose tolerance tests reported in our hospital indicated that 17.8% exceeded the recommended diagnostic criteria for gestational diabetes mellitus. It was predicted that if the results of fasting samples were revised to reflect the effect of glycolysis at room temperature, the adjusted diagnostic rate could increase to 35.3%. Conclusion Preanalytical handling of blood samples for glucose analysis is vital. Fluoride-EDTA is an imperfect antiglycolytic, even when the samples are transported and analysed rapidly provides such optimal conditions. The use of fluoride-citrate tubes may offer a viable alternative in the diagnosis of diabetes mellitus.

  14. Identification of bacteria directly from positive blood culture samples by DNA pyrosequencing of the 16S rRNA gene.

    Science.gov (United States)

    Motoshima, Maiko; Yanagihara, Katsunori; Morinaga, Yoshitomo; Matsuda, Junichi; Hasegawa, Hiroo; Kohno, Shigeru; Kamihira, Shimeru

    2012-11-01

    Rapid identification of the causative bacteria of sepsis in patients can contribute to the selection of appropriate antibiotics and improvement of patients' prognosis. Genotypic identification is an emerging technology that may provide an alternative method to, or complement, established phenotypic identification procedures. We evaluated a rapid protocol for bacterial identification based on PCR and pyrosequencing of the V1 and V3 regions of the 16S rRNA gene using DNA extracted directly from positive blood culture samples. One hundred and two positive blood culture bottles from 68 patients were randomly selected and the bacteria were identified by phenotyping and pyrosequencing. The results of pyrosequencing identification displayed 84.3 and 64.7 % concordance with the results of phenotypic identification at the genus and species levels, respectively. In the monomicrobial samples, the concordance between the results of pyrosequencing and phenotypic identification at the genus level was 87.0 %. Pyrosequencing identified one isolate in 60 % of polymicrobial samples, which were confirmed by culture analysis. Of the samples identified by pyrosequencing, 55.7 % showed consistent results in V1 and V3 targeted sequencing; other samples were identified based on the results of V1 (12.5 %) or V3 (31.8 %) sequencing alone. One isolate was erroneously identified by pyrosequencing due to high sequence similarity with another isolate. Pyrosequencing identified one isolate that was not detected by phenotypic identification. The process of pyrosequencing identification can be completed within ~4 h. The information provided by DNA-pyrosequencing for the identification of micro-organisms in positive blood culture bottles is accurate and could prove to be a rapid and useful tool in standard laboratory practice.

  15. Frequency of enterovirus detection in blood samples of neonates admitted to hospital with sepsis-like illness in Kuwait.

    Science.gov (United States)

    Ahmad, Suhail; Dalwai, Ajmal; Al-Nakib, Widad

    2013-07-01

    This study investigated the role of enteroviruses in sepsis-like illness among neonates in Kuwait. Serum samples from 139 consecutive neonates presenting with sepsis-like illness during a three and a half-year-period whose blood cultures were negative for bacterial pathogens were tested. Enterovirus RNA was detected by single-step reverse-transcription PCR (RT-PCR). Specific genotypes were identified by direct DNA sequencing of enteroviral genome. Serotype-specific antibodies in serum samples from some selected patients were detected by virus neutralization test using coxsackievirus B types (CBVs). All 139 neonates presented with sepsis-like illness and blood samples were uniformly negative for aerobic/anaerobic bacterial cultures. Fifty-six (40%) neonates had further complications of sepsis including carditis (n = 34) and multi-organ involvement (n = 22). Enterovirus RNA was detected by RT-PCR in 34 of 139 (24%) serum samples which is among the highest frequency reported so far in non-epidemic settings. Genotyping identified CBVs as most common enteroviruses, causing 19 of 34 (56%) enteroviral sepsis episodes in neonates. Of 34 carditis cases, 18 were positive for CBVs by serotyping including all 10 enterovirus RNA-positive samples. Only one fatality was observed due to liver failure in a neonate with hepatitis. Our data showed that enteroviruses are responsible for 24% of neonatal sepsis cases due to non-bacterial causes in Kuwait. The data indicate that enteroviruses should be considered in the differential diagnosis of sepsis-like illness among neonates, particularly those with negative blood cultures for bacterial pathogens. Copyright © 2013 Wiley Periodicals, Inc.

  16. Picric acid capped silver nanoparticles as a probe for colorimetric sensing of creatinine in human blood and cerebrospinal fluid samples.

    Science.gov (United States)

    Parmar, Ankita K; Valand, Nikunj N; Solanki, Kalpesh B; Menon, Shobhana K

    2016-02-21

    Creatinine is the most important parameter to be determined in the diagnosis of renal, muscular and thyroid function. The most common method for the determination of creatinine is Jaffe's reaction, a routine practice for blood and urine analysis. However, in cases of icteric and haemolyzed blood samples, interference occurs during the estimation of creatinine by other constituents present in the blood like bilirubin, creatine, and urea, which lead to wrong diagnosis. To overcome such difficulty, we have developed a silver nanoparticle (Ag NPs) based sensor for the selective determination of creatinine. In this study, a new approach has been given to the traditional Jaffe's reaction, by coating Ag NPs with picric acid (PA) to form an assembly that can selectively detect creatinine. The Ag NPs based sensor proficiently and selectively recognizes creatinine due to the ability of picric acid to bind with it and form a complex. The nanoassembly and the interactions were investigated by transmission electron microscopy (TEM), dynamic light scattering (DLS) analysis, UV-Vis spectroscopy, FT-IR spectroscopy and ESI-MS, which demonstrated the binding affinity of creatinine with PA-capped Ag NPs. A linear correlation was obtained in the range of 0.01 μM-1 μM with an R(2) value of 0.9998 and a lower detection limit of 8.4 nM. The sensor was successfully applied to different types of blood and CSF samples for the determination of creatinine, and the results were compared to that of the Jaffe's method. With the advantages of high sensitivity, selectivity and low sample volume, this method is potentially suitable for the on-site monitoring of creatinine.

  17. Assessment of persistent organic pollutants levels in blood samples from Quintana Roo, Mexico.

    Science.gov (United States)

    Antonio, Trejo-Acevedo; Edith, Rivero-Pérez Norma; Rogelio, Flores-Ramírez; Fernando, Díaz-Barriga; Catalina, Ochoa Angeles; Nelinho, Pérez-Maldonado Iván

    2013-06-01

    The Stockholm Convention on persistent organic pollutants (POPs) sought to determine baseline exposures to POPs in the general population; however, in developing countries, exposure to these chemicals in hot spots may be an issue of public health considering its magnitude. Therefore, the aim of this study was to assess the levels of POPs in the blood of children living in three communities in the Southeastern Region of Mexico. During 2007, we studied a total of 96 healthy children (aged 6-12 years). Quantitative analyses were performed using gas chromatography coupled with mass spectrometry. High levels of p,p'-DDT and its principal metabolite, p,p'-DDE, were found in the blood of children living in the three communities studied, the levels ranged from 463.5 to 9046.3 ng/g lipid and from 490.8 to 57,712.4 ng/g lipid for DDT and DDE, respectively. In addition, high levels of lindane (γ-HCH) were found, with mean levels ranging between 575.4 and 6580.6 ng/g lipid. Moreover, children living in the study region were also exposed to polychlorinated biphenyls (PCBs), and the levels of these compounds in the blood of children were very similar between the communities with mean levels of around 3000 ng/g lipid (total PCBs). In conclusion, we demonstrated that children living in the studied communities were exposed to complex chemical mixtures (DDT, DDE, lindane and PCBs) rather than to individual compounds. Therefore, in future studies it is important to understand the potential interactions between the components of these mixtures. Copyright © 2012 Elsevier GmbH. All rights reserved.

  18. Assessment of the levels of hexachlorocyclohexane in blood samples from Mexico.

    Science.gov (United States)

    Trejo-Acevedo, Antonio; Rivero-Pérez, Norma Edith; Flores-Ramirez, Rogelio; Orta-García, Sandra Teresa; Pruneda-Álvarez, Lucia Guadalupe; Pérez-Maldonado, Iván N

    2012-06-01

    The aim of this study was to evaluate hexachlorocyclohexane (HCH) exposure in children living in nine hot spots in four Mexican states. We analyzed HCH (α, β, and γ-isomers) in blood using gas chromatography/mass spectrometry. HCH exposure level in 261 children was assessed and approximately 75 % of the children studied had detectable levels of HCH. These levels ranged from 188 to 40,096.7 ng/g lipid. The highest mean levels were found in Lacanja (5,446.9 ng/g lipid), an indigenous community in Chiapas, Mexico. Our data indicate high exposure to HCH in children living in these communities.

  19. STS-55 MS3 Harris draws blood sample from Payload Specialist Schlegel

    Science.gov (United States)

    1993-01-01

    STS-55 German Payload Specialist 2 Hans Schlegel (left) serves as a test subject inside the Spacelab Deutsche 2 (SL-D2) science module onboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Mission Specialist 3 (MS3) Bernard A. Harris, Jr, a physician, performs one of many blood draws designed to help investigate human physiology under microgravity conditions. The two crewmembers use intravehicular activity (IVA) foot restraints (foot loops) in front of Rack 10, a stowage rack, to steady themselves during the procedure. Schlegel represents the German Aerospace Research Establishment (DLR).

  20. Effects of blood-feeding on olfactory sensitivity of the malaria mosquito Anopheles gambiae: application of mixed linear models to account for repeated measurements

    NARCIS (Netherlands)

    Qiu, Y.T.; Gort, G.; Torricelli, A.; Takken, W.; Loon, van J.J.A.

    2013-01-01

    Olfaction plays an important role in the host-seeking behavior of the malaria mosquito Anopheles gambiae. After a complete blood meal, female mosquitoes will not engage in host-seeking behavior until oviposition has occurred. We investigated if peripheral olfactory sensitivity changed after a blood

  1. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  2. Differences between the genomes of lymphoblastoid cell lines and blood-derived samples

    Directory of Open Access Journals (Sweden)

    Joesch-Cohen LM

    2017-02-01

    Full Text Available Lena M Joesch-Cohen, Gustavo Glusman Institute for Systems Biology, Seattle, WA, USA Abstract: Lymphoblastoid cell lines (LCLs represent a convenient research tool for expanding the amount of biologic material available from an individual. LCLs are commonly used as reference materials, most notably from the Genome in a Bottle Consortium. However, the question remains how faithfully LCL-derived genome assemblies represent the germline genome of the donor individual as compared to the genome assemblies derived from peripheral blood mononuclear cells. We present an in-depth comparison of a large collection of LCL- and peripheral blood mononuclear cell-derived genomes in terms of distributions of coverage and copy number alterations. We found significant differences in the depth of coverage and copy number calls, which may be driven by differential replication timing. Importantly, these copy number changes preferentially affect regions closer to genes and with higher GC content. This suggests that genomic studies based on LCLs may display locus-specific biases, and that conclusions based on analysis of depth of coverage and copy number variation may require further scrutiny. Keywords: genomics, whole-genome sequencing, viral transformation, copy number changes, bioinformatics

  3. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  4. EVALUATION OF BLOOD SAMPLING TIMES AND INDICATIONS FOR THERAPEUTIC DRUG MONITORING SERVICES

    Directory of Open Access Journals (Sweden)

    AISHAH HAMZAH

    2008-01-01

    Full Text Available The appropriateness of sampling times and indications for monitoring of serum drug concentrations for the purpose of therapeutic drug monitoring (TDM were evaluated at three hospitals on the east coast of Malaysia. Appropriateness criteria for indication and sampling were adapted from previously published criteria and with input from local TDM pharmacists. Six drugs were chosen, namely gentamicin, digoxin, carbamazepine, phenobarbital, phenytoin, and valproic acid. A total of 265 TDM requests were evaluated. Appropriateness of the indication for TDM ranged from 77.4% to 82%, while that for sampling ranged from 34.2% to 62.1%. There were no significant differences between the three hospitals in both categories of appropriateness. Among different drug groups, the percentage of appropriate indication was found to be highest with antiepileptic drugs. Antiepileptic drugs, however, had the lowest rate of appropriate sampling. Overall, findings from the three hospitals showed very encouraging results with almost 80% of the requests considered as appropriately indicated. However, the percentage of appropriateness of sampling was lower, and thus may require further investigation.

  5. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    controlled to great precision, but in a Cubesat , there may be no attitude determination at all. Such a Cubesat might treat sun angle and tumbling rates as...could be sensitive to small differences in motor controller timing. In these cases, the analyst might choose to model the entire deployment path, with...knowledge of the material damage model or motor controller timing precision. On the other hand, if many repeated and environmentally representative

  6. Reductions in blood lead overestimate reductions in brain lead following repeated succimer regimens in a rodent model of childhood lead exposure.

    Science.gov (United States)

    Stangle, Diane E; Strawderman, Myla S; Smith, Donald; Kuypers, Mareike; Strupp, Barbara J

    2004-03-01

    Although many studies have demonstrated the efficacy of succimer chelation in reducing blood and brain lead levels, the relative efficacy of the drug in the two tissues is less well understood. This issue is important because blood lead levels after chelation are used clinically to estimate reductions in the brain, the most critical organ in considering lead-induced neurotoxicity. The present study was designed to further investigate this issue, using multiple chelation regimens. Long-Evans rats were exposed to one of three lead exposure regimens from birth until postnatal day 40, followed by treatment with succimer (one or two 3-week regimens) or vehicle. The results indicated that one succimer regimen was significantly superior to vehicle treatment in lowering lead levels in both blood and brain across the entire 8-week follow-up period. Similarly, a second succimer regimen offered significant additional benefit relative to one regimen for both blood and brain across the 4-week follow-up period. However, several findings revealed that succimer-induced reductions in brain lead lagged behind reductions in blood lead and were generally smaller in magnitude. Furthermore, a rebound was detected in blood, but not brain, lead levels after both succimer regimens. Given the results of this study, we urge caution in using blood lead as a surrogate for brain lead levels, particularly during and immediately after chelation treatment when reductions in blood lead levels overestimate reductions in brain lead levels. The present results suggest that, in clinical use, succimer treatment may need to extend beyond the point at which blood lead levels have dropped to an "acceptable" target value in order to effectively reduce brain lead levels and minimize neurotoxicity.

  7. Assessment of the levels of polybrominated diphenyl ethers in blood samples from Guadalajara, Jalisco, Mexico.

    Science.gov (United States)

    Orta-Garcia, Sandra Teresa; León-Moreno, Lilia Carolina; González-Vega, Carolina; Dominguez-Cortinas, Gabriela; Espinosa-Reyes, Guillermo; Pérez-Maldonado, Iván N

    2012-10-01

    The purpose of this study was to measure levels of polybrominated diphenyl ethers (PBDEs) in the blood of children (50 individuals) living in Guadalajara, Jalisco, Mexico. We analyzed six PBDE congeners by gas chromatography-mass spectrometry. Total PBDE levels ranged from not detectable (nd) to 15.2 μg/L on a whole-weight basis and from nd to 6,435 ng/g lipid on a lipid-weight basis. The dominant congener in our study was BDE-153, followed by BDE-154, BDE-99, BDE-100, and BDE-47. Levels of BDE-209 were below the detection limit. Our data indicate that children living in the areas studied in this work are exposed to high levels of PBDEs.

  8. A cloned antigen for serological diagnosis of Wuchereria bancrofti microfilaremia with daytime blood samples.

    Science.gov (United States)

    Dissanayake, S; Xu, M; Piessens, W F

    1992-12-01

    By differentially screening an adult Brugia malayi cDNA library with sera from microfilaremic and amicrofilaremic donors infected with Wuchereria bancrofti, we have identified a novel parasite antigen denoted SXP-1. Recombinant SXP-1 filarial antigen is preferentially recognized by sera from microfilaremic persons with bancroftian filariasis and from skin snip-positive patients with onchocerciasis. Antibodies to SXP-1 are restricted to the IgG4 subclass and gradually decline after treatment with diethylcarbamazine. These findings indicate that it may be possible to replace microscopic examination of night blood films with a serological test designed to detect antibodies to a mix of SXP-1 and other suitable antigens for the diagnosis of microfilaremia due to bancroftian filariasis.

  9. [Intrauterine growth and biochemical levels in cord blood samples in infants less than 31 weeks gestation].

    Science.gov (United States)

    Mena Nannig, Patricia; Cubillos Celis, M Paz; Toro Jara, Claudia; Zuñiga Vergara, Carlos

    2016-01-01

    The use of greater amounts of protein and energy during the first week of life is associated with hypophosphataemia in extreme preterm babies. The lowest phosphorus levels are described in intrauterine growth restricted (IUGR) babies. To describe biochemistry levels in cord blood plasma in extreme premature, adequate and small for gestational age babies (AGA/SGA) and their relationship with plasma calcium and phosphorus levels during the first week of life. A descriptive clinical study was performed in the Neonatology Service at Hospital Dr. Sótero del Río during 2013 and 2014. A biochemical analysis of cord blood was performed on 43 premature babies, as well as plasma calcium and phosphorus levels during the first week. The adequacy for gestational age was obtained using Alarcón- Pittaluga growth curves. Statistical significance was P<.05. Cholesterol, transaminases, albumin and creatinine levels were similar for both AGA and SGA babies. Levels of pH, phosphorus, calcium and alkaline phosphatase were significantly lower in SGA babies. Urea nitrogen, uric acid and triglycerides levels were higher in SGA. The analysis during the first week showed a strong reduction in phosphorus levels, as well as an increase in calcium levels in proportion to the decrease in phosphorus in the SGA sub- group. Intrauterine malnutrition in preterm babies is expressed in the modulation of plasma levels of calcium, phosphorus, alkaline phosphatase, urea nitrogen, uric acid and triglycerides. During post-natal life, when nutritional intake begins, a decrease in phosphorus and an increase in calcium levels appear, consistent with insufficient phosphorus intake during this period. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. The effects of fin rot disease and sampling method on blood chemistry and hematocrit measurements of winter flounder, Pseudopleuronectes americanus from New Haven Harbor (1987--1990).

    Science.gov (United States)

    Ziskowski, J; Mercaldo-Allen, R; Pereira, J J; Kuropat, C; Goldberg, R

    2008-04-01

    Winter flounder from New Haven, Connecticut were evaluated for fin rot disease. Blood samples collected from healthy and diseased fish were used to measure bilirubin, calcium, hematocrit, inorganic phosphorus, osmolality, and total protein. Blood measurements were significantly affected by the presence of fin rot disease and by sampling mode (bled immediately or after 18 h). A reduction in blood chemistry values was associated with fin rot disease. Logistic regression modeling was used to identify explanatory variables contributing to the fin rot outcome in winter flounder. Blood constituent levels were higher in fish bled immediately versus 18 h post-capture, especially among fish without fin rot, suggesting that a waiting period is necessary for blood values to stabilize following initial sampling stress. This study presents evidence that winter flounder blood chemistry and hematocrit measurements are affected by fin rot disease.

  11. Effect of Repeated Whole Blood Donations on Aerobic Capacity and Hemoglobin Mass in Moderately Trained Male Subjects: A Randomized Controlled Trial

    National Research Council Canada - National Science Library

    Meurrens, Julie; Steiner, Thomas; Ponette, Jonathan; Janssen, Hans Antonius; Ramaekers, Monique; Wehrlin, Jon Peter; Vandekerckhove, Philippe; Deldicque, Louise

    2016-01-01

    The aims of the present study were to investigate the impact of three whole blood donations on endurance capacity and hematological parameters and to determine the duration to fully recover initial...

  12. Sequencing CYP2D6 for the detection of poor-metabolizers in post-mortem blood samples with tramadol.

    Science.gov (United States)

    Fonseca, Suzana; Amorim, António; Costa, Heloísa Afonso; Franco, João; Porto, Maria João; Santos, Jorge Costa; Dias, Mário

    2016-08-01

    Tramadol concentrations and analgesic effect are dependent on the CYP2D6 enzymatic activity. It is well known that some genetic polymorphisms are responsible for the variability in the expression of this enzyme and in the individual drug response. The detection of allelic variants described as non-functional can be useful to explain some circumstances of death in the study of post-mortem cases with tramadol. A Sanger sequencing methodology was developed for the detection of genetic variants that cause absent or reduced CYP2D6 activity, such as *3, *4, *6, *8, *10 and *12 alleles. This methodology, as well as the GC/MS method for the detection and quantification of tramadol and its main metabolites in blood samples was fully validated in accordance with international guidelines. Both methodologies were successfully applied to 100 post-mortem blood samples and the relation between toxicological and genetic results evaluated. Tramadol metabolism, expressed as its metabolites concentration ratio (N-desmethyltramadol/O-desmethyltramadol), has been shown to be correlated with the poor-metabolizer phenotype based on genetic characterization. It was also demonstrated the importance of enzyme inhibitors identification in toxicological analysis. According to our knowledge, this is the first study where a CYP2D6 sequencing methodology is validated and applied to post-mortem samples, in Portugal. The developed methodology allows the data collection of post-mortem cases, which is of primordial importance to enhance the application of these genetic tools to forensic toxicology and pathology.

  13. Development of an Automated and Sensitive Microfluidic Device for Capturing and Characterizing Circulating Tumor Cells (CTCs from Clinical Blood Samples.

    Directory of Open Access Journals (Sweden)

    Priya Gogoi

    Full Text Available Current analysis of circulating tumor cells (CTCs is hindered by sub-optimal sensitivity and specificity of devices or assays as well as lack of capability of characterization of CTCs with clinical biomarkers. Here, we validate a novel technology to enrich and characterize CTCs from blood samples of patients with metastatic breast, prostate and colorectal cancers using a microfluidic chip which is processed by using an automated staining and scanning system from sample preparation to image processing. The Celsee system allowed for the detection of CTCs with apparent high sensitivity and specificity (94% sensitivity and 100% specificity. Moreover, the system facilitated rapid capture of CTCs from blood samples and also allowed for downstream characterization of the captured cells by immunohistochemistry, DNA and mRNA fluorescence in-situ hybridization (FISH. In a subset of patients with prostate cancer we compared the technology with a FDA-approved CTC device, CellSearch and found a higher degree of sensitivity with the Celsee instrument. In conclusion, the integrated Celsee system represents a promising CTC technology for enumeration and molecular characterization.

  14. Detection of African Swine Fever Virus DNA in Blood Samples Stored on FTA Cards from Asymptomatic Pigs in Mbeya Region, Tanzania

    DEFF Research Database (Denmark)

    Braae, U. C.; Johansen, M. V.; Ngowi, H. A.;

    2015-01-01

    The aim of the study was to assess whether blood samples collected onto FTA® cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected...... pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA® cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level...... of viral DNA (Ct 36-45). Four pigs were positive in one of the duplicate samples only, but clear products of the expected size were obtained when the reactions were analysed by gel electrophoresis. For comparison, blood samples from pigs experimentally infected with either a pathogenic (OURT T88...

  15. Comparison of genomic DNA extraction techniques from whole blood samples: a time, cost and quality evaluation study.

    Science.gov (United States)

    Chacon-Cortes, Diego; Haupt, Larisa M; Lea, Rod A; Griffiths, Lyn R

    2012-05-01

    Genomic DNA obtained from patient whole blood samples is a key element for genomic research. Advantages and disadvantages, in terms of time-efficiency, cost-effectiveness and laboratory requirements, of procedures available to isolate nucleic acids need to be considered before choosing any particular method. These characteristics have not been fully evaluated for some laboratory techniques, such as the salting out method for DNA extraction, which has been excluded from comparison in different studies published to date. We compared three different protocols (a traditional salting out method, a modified salting out method and a commercially available kit method) to determine the most cost-effective and time-efficient method to extract DNA. We extracted genomic DNA from whole blood samples obtained from breast cancer patient volunteers and compared the results of the product obtained in terms of quantity (concentration of DNA extracted and DNA obtained per ml of blood used) and quality (260/280 ratio and polymerase chain reaction product amplification) of the obtained yield. On average, all three methods showed no statistically significant differences between the final result, but when we accounted for time and cost derived for each method, they showed very significant differences. The modified salting out method resulted in a seven- and twofold reduction in cost compared to the commercial kit and traditional salting out method, respectively and reduced time from 3 days to 1 hour compared to the traditional salting out method. This highlights a modified salting out method as a suitable choice to be used in laboratories and research centres, particularly when dealing with a large number of samples.

  16. Practical and reliable enzyme test for the detection of mucopolysaccharidosis IVA (Morquio Syndrome type A) in dried blood samples.

    Science.gov (United States)

    Camelier, Marli V; Burin, Maira G; De Mari, Jurema; Vieira, Taiane A; Marasca, Giórgia; Giugliani, Roberto

    2011-09-18

    Mucopolysaccharidosis IVA (MPS IVA), or Morquio Syndrome type A, is an autosomal recessive disease caused by deficiency of the lysosomal enzyme N-acetylgalactosamine-6-sulfatase (GALNS), resulting in excessive lysosomal storage of keratan sulfate in many tissues and organs. This accumulation causes a severe skeletal dysplasia with short stature, and affects the eye, heart and other organs, with many signs and symptoms. Morquio A syndrome is estimated to occur in 1 in 200,000 to 300,000 live births. Clinical trials with enzyme replacement therapy for this disease are in progress, and it is probable that the treatment, when available, would be more effective if started early. We describe an innovative fluorometric method for the assay of GALNS in dried blood spots (DBS). We used dried blood spots (DBS) as the enzyme source and compared it with leukocytes samples, having studied 25 MPS IVA patients and 54 healthy controls. We optimized the assay conditions, including incubation time and stability of DBS samples. To eppendorf type tubes containing a 3-mm diameter blood spot we added elution liquid and substrate solution. After 2 different incubations at 37°C, the amount of hydrolyzed product was compared with a calibrator to allow the quantification of the enzyme activity. Results in DBS were compared to the ones obtained in leukocytes using the standard technique. The fluorescent methodology was validated in our laboratory and the assay was found sensitive and specific, allowing reliable detection of MPS IVA patients. The use of DBS simplifies the collection and transport steps, and is especially useful for testing patients from more remote areas of large countries, and when samples need to cross country borders. This assay could be easily incorporated into the protocol of reference laboratories and play a role in the screening for MPS IVA, contributing to earlier detection of affected patients. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Sensitivity of laser light depolarization analysis for detection of malaria in blood samples.

    Science.gov (United States)

    Padial, Manuel Martínez; Subirats, Mercedes; Puente, Sabino; Lago, Mar; Crespo, Santiago; Palacios, Gonzalo; Baquero, Margarita

    2005-05-01

    Automated light depolarization analysis could be a useful tool for diagnosing malarial infections. This work discusses the results of a diagnostic efficacy study on 411 samples from patients with suspected malaria infection performed with a Cell-Dyn 4000 analyser. Light dispersed at 90 degrees and depolarized can be used for identifying and counting eosinophils. However, other cell populations with depolarizing capacity occur in malarial samples; these result from leukocytes ingesting haemozoin that is derived from the degradation of the haem group of haemoglobin performed by the parasite. A sensitivity of 72 % and specificity of 98 % were recorded, with positive and negative predictive values of 78 % and 97 %, respectively. Although the sensitivity level of the automated light depolarization analysis is not adequate to replace the existing methods for the diagnosis of parasitic diseases, it could alert clinicians to unsuspected infections by parasites, particularly those from the genus Plasmodium.

  18. Dioxin-like activity of environmental compounds in human blood and environmental samples

    DEFF Research Database (Denmark)

    Long, Manhai; Bonefeld-Jørgensen, Eva Cecilie

    2012-01-01

    R transactivation bioassay is utilized in an array of projects to study the AhR-mediated activities of individual chemicals and mixtures and for epidemiological purposes. This review summarizes a series of studies regarding the DL-activity of single compounds and complex compound mixtures in the environment...... a cost-effective and integrated screening tool for measurement of the DL-activity in human, environmental and commercial samples....

  19. Dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography of liver tumours without blood sampling

    DEFF Research Database (Denmark)

    Keiding, S; Munk, O L; Schiøtt, K M

    2000-01-01

    in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans...... with arterial blood sampling in human subjects: First, data from four patients with no liver tumours and five patients with liver tumours were used as a training group. Volumes of interest were defined in the descending aorta (aorta VOIs) by four different methods. K values were calculated based...... on the corresponding TACs and compared with those based on TACs of the arterial blood sample radioactivity concentrations. The aorta VOI which gave K values that were in best agreement with the K values based on the arterial blood sample measurements was called the AORTA-VOI. Use of the AORTA-VOI was subsequently...

  20. Color light-emitting diode reflection topography: validation of keratometric repeatability in a large sample of wide cylindrical-range corneas

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2015-02-01

    Full Text Available Anastasios John Kanellopoulos,1,2 George Asimellis11LaserVision.gr Clinical and Research Eye Institute, Athens, Greece; 2New York University Medical School, New York, NY, USAPurpose: To investigate repeatability of steep and flat keratometry measurements, as well as astigmatism axis in cohorts with normal range and regular astigmatic such as: eyes following laser-assisted in situ keratomileusis (LASIK and normal population, as well as cohorts of high and irregular astigmatism such as keratoconic eyes, and keratoconic eyes following corneal collagen cross-linking, employing a novel corneal reflection topography device.Methods: Steep and flat keratometry and astigmatism axis measurement repeatability was investigated employing a novel multicolored-spot reflection topographer (Cassini in four study groups, namely a post myopic LASIK-treated Group A, a keratoconus Group B, a post-CXL keratoconus Group C, and a control Group D of routine healthy patients. Three separate, maps were obtained employing the Cassini, enabling investigation of the intra-individual repeatability by standard deviation. Additionally we investigated in all groups,the Klyce surface irregularity indices for keratoconus, the SAI (surface asymmetry index and the SRI (surface regularity index.Results: Flat keratometry repeatability was 0.74±0.89 (0.03 to 5.26 diopters (D in the LASIK Group A, 0.88±1.45 (range minimum to maximum, 0.00 to 7.84 D in the keratoconic Group B, and 0.71±0.94 (0.02 to 6.23 D in the cross-linked Group C. The control Group D had flat keratometry repeatability 0.36±0.46 (0.00 to 2.71 D. Steep keratometry repeatability was 0.64±0.82 (0.01 to 4.81 D in the LASIK Group A, 0.89±1.22 (0.02 to 7.85 D in the keratoconic Group B, and 0.93±1.12 (0.04 to 5.93 D in the cross-linked Group C. The control Group D had steep keratometry repeatability 0.41±0.50 (0.00 to 3.51 D. Axis repeatability was 3.45±1.62° (0.38 to 7.78° for the LASIK Group A, 4.12±3.17

  1. Rapid and Sensitive Salmonella Typhi Detection in Blood and Fecal Samples Using Reverse Transcription Loop-Mediated Isothermal Amplification.

    Science.gov (United States)

    Fan, Fenxia; Yan, Meiying; Du, Pengcheng; Chen, Chen; Kan, Biao

    2015-09-01

    Typhoid fever caused by Salmonella enterica serovar Typhi remains a significant public health problem in developing countries. Although the main method for diagnosing typhoid fever is blood culture, the test is time consuming and not always able to detect infections. Thus, it is very difficult to distinguish typhoid from other infections in patients with nonspecific symptoms. A simple and sensitive laboratory detection method remains necessary. The purpose of this study is to establish and evaluate a rapid and sensitive reverse transcription-based loop-mediated isothermal amplification (RT-LAMP) method to detect Salmonella Typhi infection. In this study, a new specific gene marker, STY1607, was selected to develop a STY1607-RT-LAMP assay; this is the first report of specific RT-LAMP detection assay for typhoid. Human-simulated and clinical blood/stool samples were used to evaluate the performance of STY1607-RT-LAMP for RNA detection; this method was compared with STY1607-LAMP, reverse transcription real-time polymerase chain reaction (rRT-PCR), and bacterial culture methods for Salmonella Typhi detection. Using mRNA as the template, STY1607-RT-LAMP exhibited 50-fold greater sensitivity than STY1607-LAMP for DNA detection. The STY1607-RT-LAMP detection limit is 3 colony-forming units (CFU)/mL for both the pure Salmonella Typhi samples and Salmonella Typhi-simulated blood samples and was 30 CFU/g for the simulated stool samples, all of which were 10-fold more sensitive than the rRT-PCR method. RT-LAMP exhibited improved Salmonella Typhi detection sensitivity compared to culture methods and to rRT-PCR of clinical blood and stool specimens from suspected typhoid fever patients. Because it can be performed without sophisticated equipment or skilled personnel, RT-LAMP is a valuable tool for clinical laboratories in developing countries. This method can be applied in the clinical diagnosis and care of typhoid fever patients as well as for a quick public health response.

  2. Evaluation of middlebrook 7H11 associated with human or sheep blood for the detection of mycobacterium tuberculosis in sputum samples

    OpenAIRE

    Agapito, Juan; Escuela de Tecnología Médica, Facultad de Medicina, Universidad Peruana Cayetano Heredia. Lima, Perú Instituto de Medicina Tropical Alexander von Humboldt, Universidad Peruana Cayetano Heredia. Lima, Perú. microbiólogo.; Cuadros, Luis; Escuela de Tecnología Médica, facultad de Medicina, universidad Peruana Cayetano Heredia. Lima, Perú. Tecnólogo médico.; Tarrillo, Sergio; Escuela de Tecnología Médica, facultad de Medicina, universidad Peruana Cayetano Heredia. Lima, Perú. Tecnólogo médico.; Soto, Alonso; Asociación Latinoamericana de Biotecnología. Lima, Perú. Hospital Nacional Hipólito unanue. Lima, Perú. Facultad de Medicina, universidad Ricardo Palma. Lima, Perú. Médico Internista.

    2009-01-01

    Objective. To evaluate the diagnostic yield of the media Middlebrook 7H11 combined with human or ovine blood in comparison with the Ogawa solid media for the diagnosis of pulmonary tuberculosis. Material and methods. We evaluated sputum samples of patients with clinical suspicion of pulmonary tuberculosis. The samples were seeded in Middlebrook 7H11 agar associated with human or ovine blood and in Ogawa media. Results. A total of 130 samples were collected. The positivity for M.tuberculos...

  3. Mercury in human hair and blood samples from people living in Wanshan mercury mine area, Guizhou, China: an XAS study.

    Science.gov (United States)

    Li, Yu-Feng; Chen, Chunying; Li, Bai; Li, Wei; Qu, Liya; Dong, Zeqin; Nomura, Masaharu; Gao, Yuxi; Zhao, Jinxuan; Hu, Wei; Zhao, Yuliang; Chai, Zhifang

    2008-03-01

    Human hair and blood samples from persons living in the town of Wanshan, a mercury mine area in Guizhou Province of China, were collected and the quantitative speciation and structural information of Hg and S in hair samples and of Hg in erythrocyte and serum samples were studied using X-ray absorption spectroscopy. Least-squares fitting of the X-ray absorption near-edge spectra found that inorganic mercury is the major mercury species in hair samples (91.74%), while inorganic and methyl mercury are both about 50% of total mercury in RBC and serum samples, which is in agreement with the data obtained by acidic extraction, fractionation of Hg(2+) and CH(3)Hg(+) and quantification by ICP-MS. Curve-fitting analysis revealed that the Hg-S bond length and coordination number in hair were 0.248+/-0.002 nm and 3.10, respectively, while the S-Hg bond length and coordination number in hair were 0.236+/-0.002 nm and 4.05. The Hg-S bond length and coordination number in RBC were 0.251+/-0.003 nm and 4.09, respectively, while they were 0.228+/-0.002 nm and 4.08 in serum, respectively. The techniques for speciation, structural and binding information described in this study will find the potential application in similar studies of other elements.

  4. The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin

    Science.gov (United States)

    Küme, Tuncay; Şişman, Ali Rıza; Solak, Ahmet; Tuğlu, Birsen; Çinkooğlu, Burcu; Çoker, Canan

    2012-01-01

    Introductıon: We evaluated the effect of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin. Materials and methods: In this multi-step experimental study, percent dilution ratios (PDRs) and final heparin concentrations (FHCs) were calculated by gravimetric method for determining the effect of syringe volume (1, 2, 5 and 10 mL), needle size (20, 21, 22, 25 and 26 G) and sample volume (0.5, 1, 2, 5 and 10 mL). The effect of different PDRs and FHCs on blood gas and electrolyte parameters were determined. The erroneous results from nonstandardized sampling were evaluated according to RiliBAK’s TEa. Results: The increase of PDRs and FHCs was associated with the decrease of syringe volume, the increase of needle size and the decrease of sample volume: from 2.0% and 100 IU/mL in 10 mL-syringe to 7.0% and 351 IU/mL in 1 mL-syringe; from 4.9% and 245 IU/mL in 26G to 7.6% and 380 IU/mL in 20 G with combined 1 mL syringe; from 2.0% and 100 IU/mL in full-filled sample to 34% and 1675 IU/mL in 0.5 mL suctioned sample into 10 mL-syringe. There was no statistical difference in pH; but the percent decreasing in pCO2, K+, iCa2+, iMg2+; the percent increasing in pO2 and Na+ were statistical significance compared to samples full-filled in syringes. The all changes in pH and pO2 were acceptable; but the changes in pCO2, Na+, K+ and iCa2+ were unacceptable according to TEa limits except fullfilled-syringes. Conclusions: The changes in PDRs and FHCs due nonstandardized sampling in syringe washed with liquid heparin give rise to erroneous test results for pCO2 and electrolytes. PMID:22838185

  5. International study to evaluate PCR methods for detection of Trypanosoma cruzi DNA in blood samples from Chagas disease patients.

    Directory of Open Access Journals (Sweden)

    Alejandro G Schijman

    Full Text Available BACKGROUND: A century after its discovery, Chagas disease still represents a major neglected tropical threat. Accurate diagnostics tools as well as surrogate markers of parasitological response to treatment are research priorities in the field. The purpose of this study was to evaluate the performance of PCR methods in detection of Trypanosoma cruzi DNA by an external quality evaluation. METHODOLOGY/FINDINGS: An international collaborative study was launched by expert PCR laboratories from 16 countries. Currently used strategies were challenged against serial dilutions of purified DNA from stocks representing T. cruzi discrete typing units (DTU I, IV and VI (set A, human blood spiked with parasite cells (set B and Guanidine Hidrochloride-EDTA blood samples from 32 seropositive and 10 seronegative patients from Southern Cone countries (set C. Forty eight PCR tests were reported for set A and 44 for sets B and C; 28 targeted minicircle DNA (kDNA, 13 satellite DNA (Sat-DNA and the remainder low copy number sequences. In set A, commercial master mixes and Sat-DNA Real Time PCR showed better specificity, but kDNA-PCR was more sensitive to detect DTU I DNA. In set B, commercial DNA extraction kits presented better specificity than solvent extraction protocols. Sat-DNA PCR tests had higher specificity, with sensitivities of 0.05-0.5 parasites/mL whereas specific kDNA tests detected 5.10(-3 par/mL. Sixteen specific and coherent methods had a Good Performance in both sets A and B (10 fg/µl of DNA from all stocks, 5 par/mL spiked blood. The median values of sensitivities, specificities and accuracies obtained in testing the Set C samples with the 16 tests determined to be good performing by analyzing Sets A and B samples varied considerably. Out of them, four methods depicted the best performing parameters in all three sets of samples, detecting at least 10 fg/µl for each DNA stock, 0.5 par/mL and a sensitivity between 83.3-94.4%, specificity of 85

  6. International study to evaluate PCR methods for detection of Trypanosoma cruzi DNA in blood samples from Chagas disease patients.

    Directory of Open Access Journals (Sweden)

    Alejandro G Schijman

    Full Text Available BACKGROUND: A century after its discovery, Chagas disease still represents a major neglected tropical threat. Accurate diagnostics tools as well as surrogate markers of parasitological response to treatment are research priorities in the field. The purpose of this study was to evaluate the performance of PCR methods in detection of Trypanosoma cruzi DNA by an external quality evaluation. METHODOLOGY/FINDINGS: An international collaborative study was launched by expert PCR laboratories from 16 countries. Currently used strategies were challenged against serial dilutions of purified DNA from stocks representing T. cruzi discrete typing units (DTU I, IV and VI (set A, human blood spiked with parasite cells (set B and Guanidine Hidrochloride-EDTA blood samples from 32 seropositive and 10 seronegative patients from Southern Cone countries (set C. Forty eight PCR tests were reported for set A and 44 for sets B and C; 28 targeted minicircle DNA (kDNA, 13 satellite DNA (Sat-DNA and the remainder low copy number sequences. In set A, commercial master mixes and Sat-DNA Real Time PCR showed better specificity, but kDNA-PCR was more sensitive to detect DTU I DNA. In set B, commercial DNA extraction kits presented better specificity than solvent extraction protocols. Sat-DNA PCR tests had higher specificity, with sensitivities of 0.05-0.5 parasites/mL whereas specific kDNA tests detected 5.10(-3 par/mL. Sixteen specific and coherent methods had a Good Performance in both sets A and B (10 fg/µl of DNA from all stocks, 5 par/mL spiked blood. The median values of sensitivities, specificities and accuracies obtained in testing the Set C samples with the 16 tests determined to be good performing by analyzing Sets A and B samples varied considerably. Out of them, four methods depicted the best performing parameters in all three sets of samples, detecting at least 10 fg/µl for each DNA stock, 0.5 par/mL and a sensitivity between 83.3-94.4%, specificity of 85

  7. Measurement of carboxyhemoglobin in forensic blood samples using UV-visible spectrometry and improved principal component regression

    Energy Technology Data Exchange (ETDEWEB)

    Egan, William; Morgan, Stephen L. [Department of Chemistry and Biochemistry, The University of South Carolina, Columbia, South Carolina 29208 (United States)] Brewer, William E. [Toxicology Department, South Carolina Law Enforcement Division, 4416 Broad River Road, Columbia, South Carolina 29210 (United States)

    1999-02-01

    The forensic determination of carboxyhemoglobin (COHb) in blood was performed by using an improved principal component regression (PCR) technique applied to UV-visible spectra. Calibration data were decomposed into principal components, and the principal components useful for prediction were selected by their correlation with calibration spectra. Cross-validation of prediction results was done by leverage-corrected residuals. Confidence and prediction intervals derived from classical regression theory were found to be reasonable in size. The results compared favorably to a comparison study conducted by using a CO Oximeter method. In analysis of forensic case study samples, the improved PCR method allowed detection of abnormal samples and successfully predicted percentages of COHb and methemoglobin (MetHb), and provided error estimates for those predictions. {copyright} {ital 1999} {ital Society for Applied Spectroscopy}

  8. The use of dried blood spot samples in the diagnosis of lysosomal storage disorders--current status and perspectives.

    Science.gov (United States)

    Reuser, Arnold J; Verheijen, Frans W; Bali, Deeksha; van Diggelen, Otto P; Germain, Dominique P; Hwu, Wuh-Liang; Lukacs, Zoltan; Mühl, Adolf; Olivova, Petra; Piraud, Monique; Wuyts, Birgit; Zhang, Kate; Keutzer, Joan

    2011-01-01

    Dried blood spot (DBS) methods are currently available for identification of a range of lysosomal storage disorders (LSDs). These disorders are generally characterized by a deficiency of activity of a lysosomal enzyme and by a broad spectrum of phenotypes. Diagnosis of LSD patients is often delayed, which is of particular concern as therapeutic outcomes (e.g. enzyme replacement therapy) are generally more favorable in early disease stages. Experts in the field of LSDs diagnostics and screening programs convened and reviewed experiences with the use of DBS methods, and discuss the diagnostic challenges, possible applications and quality programs in this paper. Given the easy sampling and shipping and stability of samples, DBS has evident advantages over other laboratory methods and can be particularly helpful in the early identification of affected LSD patients through neonatal screening, high-risk population screening or family screening.

  9. Straightforward and rapid determination of sulfadoxine and sulfamethoxazole in capillary blood on sampling paper with liquid chromatography and UV detection.

    Science.gov (United States)

    Lindkvist, J; Malm, M; Bergqvist, Y

    2009-04-01

    A method for the determination of sulfadoxine and sulfamethoxazole in capillary blood on sampling paper has been developed and validated. The method is straightforward with minimal sample preparation, and is suitable for rural settings. Separation of sulfadoxine, sulfamethoxazole and internal standard was performed using a Purospher STAR RP-18 endcapped LC column (150x4.6mm) with a mobile phase consisting of acetonitrile:sodium acetate buffer pH 5.2, I=0.1 (1:2, v/v). For sulfadoxine, the within-day precision was 5.3% at 15micromol/l and 3.7% at 600micromol/l, while for sulfamethoxazole it was 5.7% at 15micromol/l and 3.8% at 600micromol/l. The lower limit of quantification was determined to 5micromol/l and precision was 5.5% and 5.0% for sulfadoxine and sulfamethoxazole, respectively.

  10. Accurate measurement of circulating mitochondrial DNA content from human blood samples using real-time quantitative PCR.

    Science.gov (United States)

    Ajaz, Saima; Czajka, Anna; Malik, Afshan

    2015-01-01

    We describe a protocol to accurately measure the amount of human mitochondrial DNA (MtDNA) in peripheral blood samples which can be modified to quantify MtDNA from other body fluids, human cells, and tissues. This protocol is based on the use of real-time quantitative PCR (qPCR) to quantify the amount of MtDNA relative to nuclear DNA (designated the Mt/N ratio). In the last decade, there have been increasing numbers of studies describing altered MtDNA or Mt/N in circulation in common nongenetic diseases where mitochondrial dysfunction may play a role (for review see Malik and Czajka, Mitochondrion 13:481-492, 2013). These studies are distinct from those looking at genetic mitochondrial disease and are attempting to identify acquired changes in circulating MtDNA content as an indicator of mitochondrial function. However, the methodology being used is not always specific and reproducible. As more than 95 % of the human mitochondrial genome is duplicated in the human nuclear genome, it is important to avoid co-amplification of nuclear pseudogenes. Furthermore, template preparation protocols can also affect the results because of the size and structural differences between the mitochondrial and nuclear genomes. Here we describe how to (1) prepare DNA from blood samples; (2) pretreat the DNA to prevent dilution bias; (3) prepare dilution standards for absolute quantification using the unique primers human mitochondrial genome forward primer (hMitoF3) and human mitochondrial genome reverse primer(hMitoR3) for the mitochondrial genome, and human nuclear genome forward primer (hB2MF1) and human nuclear genome reverse primer (hB2MR1) primers for the human nuclear genome; (4) carry out qPCR for either relative or absolute quantification from test samples; (5) analyze qPCR data; and (6) calculate the sample size to adequately power studies. The protocol presented here is suitable for high-throughput use.

  11. Limited sampling strategy for prolonged-release tacrolimus in renal transplant patients by use of the dried blood spot technique.

    Science.gov (United States)

    van Boekel, G A J; Donders, A R T; Hoogtanders, K E J; Havenith, T R A; Hilbrands, L B; Aarnoutse, R E

    2015-07-01

    The aim of this study was to develop a clinically applicable limited sampling strategy for ambulatory Caucasian kidney transplant patients to estimate area under the curve in a 24-h period (AUC0-24) of prolonged-release tacrolimus. Twenty six kidney recipients, at least 6 months after transplantation, receiving prolonged-release tacrolimus, were enrolled. In each patient, seven blood samples were collected during a period of 24 h by use of the validated dried blood spot method. Best subset selection multiple linear regression was performed to derive limited sampling strategy (LSS). The equations were constrained to include a maximum of three samples collected within 4 h after the intake to maintain clinical applicability. To assess the predictive performance of LSS, residuals for each patient were calculated based on models fitted to a dataset where that patient was omitted. The prediction formula for the AUC(0-24) using the time points 0, 2, and 4 h after ingestion (C(0h)-C(2h)-C(4h)) provided the highest correlation with the AUC(0-24) (r(2) = 0.95): AUC0-24 = 44.9 + 8.9 × C(0h) + 2.1 × C(2h) + 7.6 × C(4h). Measures for bias and precision, i.e., median percentage prediction error (MPPE) and median absolute prediction error (MAPE), were 0.4 and 4.8%, respectively. For the same patients, the correlation between C(24h) and AUC0-24 was worse (r(2) = 0.77) while MPPE and MAPE were 6.2 and 7.2%, respectively. In the outpatient department, a LSS using C(0h)-C(2h)-C(4h) can be used for reliable estimation of the AUC(0-24) of prolonged-release tacrolimus.

  12. Dioxin-like activity of environmental compounds in human blood and environmental samples

    DEFF Research Database (Denmark)

    Long, Manhai; Bonefeld-Jørgensen, Eva Cecilie

    2012-01-01

    and humans. We found that some pesticides, plasticizers and phytoestrogens can activate the AhR, and the combined effect of compounds with no or weak AhR potency cannot be ignored. The significant DL-activity in the wastewater effluent indicates the treatment is not sufficient to prevent contamination...... of surface waters with dioxins. Our results from human studies suggest that the serum DL-activity reflect the complex mixture of persistent organic pollutants (POPs). Greenlandic Inuit had lower serum DL-activity level compared to Europeans, probably due to long distance from the dioxin sources and UV...... a cost-effective and integrated screening tool for measurement of the DL-activity in human, environmental and commercial samples....

  13. Development and validation of a dried blood spot LC-MS/MS assay to quantify ranitidine in paediatric samples.

    Science.gov (United States)

    Yakkundi, Shirish; Millership, Jeff; Collier, Paul; Shields, Michael D; McElnay, James

    2011-12-15

    A novel approach has been developed to determine ranitidine in paediatric samples using dried blood spots (DBS) on Guthrie cards (Whatman 903). A selective and sensitive HPLC-MS/MS assay has been developed and validated using small volumes of blood (30 μl). A 6 mm disc was punched from each DBS and extracted with methanolic solution of the internal standard (IS) nizatidine. This was further subjected to solid phase extraction (SPE), followed by reversed phase HPLC separation, using a XBridge™ C18 column and mobile phase 10 mM ammonium acetate/methanol (98:2 v/v) with a flow rate of 0.3 mL/min. This was combined with multiple reaction monitoring (MRM) mass detection using electrospray ionisation (ESI). The calibration curve for ranitidine was found linear over the range 10-500 ng/mL (r=0.996). The limit of quantification (LOQ) of the method was validated at 10 ng/mL. Accuracy and precision values for within and between days were <20% at the LOQ and <15% at all other concentrations. The validated DBS method was successfully applied to a clinical study employing 81 samples from 36 paediatric patients.

  14. Association of Global DNA Methylation and Global DNA Hydroxymethylation with Metals and Other Exposures in Human Blood DNA Samples

    Science.gov (United States)

    Tang, Wan-yee; Shang, Yan; Umans, Jason G.; Francesconi, Kevin A.; Goessler, Walter; Ledesma, Marta; Leon, Montserrat; Laclaustra, Martin; Pollak, Jonathan; Guallar, Eliseo; Cole, Shelley A.; Fallin, M. Dani; Navas-Acien, Ana

    2014-01-01

    Background: The association between human blood DNA global methylation and global hydroxymethylation has not been evaluated in population-based studies. No studies have evaluated environmental determinants of global DNA hydroxymethylation, including exposure to metals. Objective: We evaluated the association between global DNA methylation and global DNA hydroxymethylation in 48 Strong Heart Study participants for which selected metals had been measured in urine at baseline and DNA was available from 1989–1991 (visit 1) and 1998–1999 (visit 3). Methods: We measured the percentage of 5-methylcytosine (5-mC) and 5-hydroxymethylcytosine (5-hmC) in samples using capture and detection antibodies followed by colorimetric quantification. We explored the association of participant characteristics (i.e., age, adiposity, smoking, and metal exposure) with both global DNA methylation and global DNA hydroxymethylation. Results: The Spearman’s correlation coefficient for 5-mC and 5-hmC levels was 0.32 (p = 0.03) at visit 1 and 0.54 (p Ledesma M, Leon M, Laclaustra M, Pollak J, Guallar E, Cole SA, Fallin MD, Navas-Acien A. 2014. Association of global DNA methylation and global DNA hydroxymethylation with metals and other exposures in human blood DNA samples. Environ Health Perspect 122:946–954; http://dx.doi.org/10.1289/ehp.1306674 PMID:24769358

  15. Assessment of DDT, DDE, and 1-hydroxypyrene levels in blood and urine samples in children from Chiapas Mexico.

    Science.gov (United States)

    Martínez-salinas, Rebeca I; Pérez-Maldonado, Iván N; Batres-Esquivel, Lilia E; Flores-Ramírez, Rogelio; Díaz-Barriga, Fernando

    2011-08-01

    The aim of this study was assess co-exposure to DDT, DDE (main DDT metabolite), and PAHs (1-hydroxypyrene) in areas where biomass is used to cook and to heat homes and where DDT was used to combat malaria transmission. During 2009, we analyzed a total of 190 blood and urine samples from children living in six communities in Mexico. Quantitative analyses of DDT and DDE were performed using gas chromatography coupled with mass spectrometry. Analyses of 1-hydroxypyrene were performed by HPLC using a fluorescence detector. In this work, we found high levels of DDT and its principal metabolite (DDE) in the blood of children living in four communities in Chiapas located in the southeastern region of Mexico (range, samples (range, 0.02 to 4.82 μmol/mol creatinine). An important finding was that around one third of the children studied in these areas were co-exposed to the three compounds. This study demonstrates that children in these communities were exposed to DDT and its metabolites, and to other contaminants generated by the combustion of firewood. Therefore, the complex mixture studied in this study (PAHs and DDT/DDE) requires further research.

  16. Loop-mediated isothermal amplification assay for the detection of Ehrlichia canis DNA in blood samples from dogs

    Directory of Open Access Journals (Sweden)

    SA Faggion

    2013-01-01

    Full Text Available The rickettsial bacterium Ehrlichia canis is the etiological agent of canine monocytic ehrlichiosis, one of the most important canine tick-borne diseases in the world. In this study, a loop-mediated isothermal amplification (LAMP assay was developed for detection of E. canis DNA using LAMP primers targeting the groESL operon. Reactions were performed at 60°C for 60 min and the results were visualized by gel electrophoresis. Successful amplification was obtained using plasmid DNA containing a fragment of the groESL operon and DNA extracted from blood samples that tested positive for E. canis by real-time PCR. The specificity of amplification was confirmed by EcoRI restriction of internal sites in the LAMP primers and no cross-reactivity with blood samples positive for Babesia spp., another common tick-borne pathogen, was observed. The high cost of nucleic acid tests (NAT is one of the disadvantages for their large-scale use as routine diagnostic tests. The E. canis LAMP assay developed here is an interesting alternative to PCR since it does not require a thermocycler, thus reducing costs for the veterinary clinical laboratory.

  17. Sources of pre-analytical variations in yield of DNA extracted from blood samples: analysis of 50,000 DNA samples in EPIC.

    Directory of Open Access Journals (Sweden)

    Elodie Caboux

    Full Text Available The European Prospective Investigation into Cancer and nutrition (EPIC is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88% performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies.

  18. Sources of Pre-Analytical Variations in Yield of DNA Extracted from Blood Samples: Analysis of 50,000 DNA Samples in EPIC

    Science.gov (United States)

    Caboux, Elodie; Lallemand, Christophe; Ferro, Gilles; Hémon, Bertrand; Mendy, Maimuna; Biessy, Carine; Sims, Matt; Wareham, Nick; Britten, Abigail; Boland, Anne; Hutchinson, Amy; Siddiq, Afshan; Vineis, Paolo; Riboli, Elio; Romieu, Isabelle; Rinaldi, Sabina; Gunter, Marc J.; Peeters, Petra H. M.; van der Schouw, Yvonne T.; Travis, Ruth; Bueno-de-Mesquita, H. Bas; Canzian, Federico; Sánchez, Maria-José; Skeie, Guri; Olsen, Karina Standahl; Lund, Eiliv; Bilbao, Roberto; Sala, Núria; Barricarte, Aurelio; Palli, Domenico; Navarro, Carmen; Panico, Salvatore; Redondo, Maria Luisa; Polidoro, Silvia; Dossus, Laure; Boutron-Ruault, Marie Christine; Clavel-Chapelon, Françoise; Trichopoulou, Antonia; Trichopoulos, Dimitrios; Lagiou, Pagona; Boeing, Heiner; Fisher, Eva; Tumino, Rosario; Agnoli, Claudia; Hainaut, Pierre

    2012-01-01

    The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies. PMID:22808065

  19. Repeated measurements of blood lactate concentration as a prognostic marker in horses with acute colitis evaluated with classification and regression trees (CART) and random forest analysis

    DEFF Research Database (Denmark)

    Petersen, Mette Bisgaard; Tolver, Anders; Husted, Louise

    2016-01-01

    admitted with acute colitis (random...... forest analysis. Ponies and Icelandic horses made up 59% of the population, whilst the remaining 41% were horses. Blood lactate concentration at admission was the only individual parameter significantly associated with probability of survival to discharge (P 

  20. Performance Testing of PCR Assay in Blood Samples for the Diagnosis of Toxoplasmic Encephalitis in AIDS Patients from the French Departments of America and Genetic Diversity of Toxoplasma gondii: A Prospective and Multicentric Study.

    Directory of Open Access Journals (Sweden)

    Daniel Ajzenberg

    2016-06-01

    Full Text Available Toxoplasmic encephalitis in patients with AIDS is a life-threatening disease mostly due to reactivation of Toxoplasma gondii cysts in the brain. The main objective of this study was to evaluate the performance of real-time PCR assay in peripheral blood samples for the diagnosis of toxoplasmic encephalitis in AIDS patients in the French West Indies and Guiana.Adult patients with HIV and suspicion of toxoplasmic encephalitis with start of specific antitoxoplasmic therapy were included in this study during 40 months. The real-time PCR assay targeting the 529 bp repeat region of T. gondii was performed in two different centers for all blood samples. A Neighbor-Joining tree was reconstructed from microsatellite data to examine the relationships between strains from human cases of toxoplasmosis in South America and the Caribbean. A total of 44 cases were validated by a committee of experts, including 36 cases with toxoplasmic encephalitis. The specificity of the PCR assay in blood samples was 100% but the sensitivity was only 25% with moderate agreement between the two centers. Altered level of consciousness and being born in the French West Indies and Guiana were the only two variables that were associated with significantly decreased risk of false negative results with the PCR assay.Our results showed that PCR sensitivity in blood samples increased with severity of toxoplasmic encephalitis in AIDS patients. Geographic origin of patients was likely to influence PCR sensitivity but there was little evidence that it was caused by differences in T. gondii strains.ClinicalTrials.gov NCT00803621.

  1. Comparison of Culture and Multiplex PCR Technique for Detection of Brucella abortus and Brucella melitensis from Human Blood Samples

    Directory of Open Access Journals (Sweden)

    Vahhab Piranfar

    2013-12-01

    Full Text Available Background: To compare culture methods with multiplex PCR technique for identification of Brucella abortus and Brucella melitensis from suspicious patients with clinical history of brucellosis and positive serological test (Rose Bengal test and serum agglutination test. Materials and Methods: In this study, 160 blood samples from patients suspected of Brucellosis with high serum titers of 1/80 were studied. All samples were cultured in Brucella-specific media. Brucella species were identified by using microbiological methods. DNA was extracted with Phenol-chloroform DNA extraction method. IS711 was amplified simultaneously using three specific primers and obtained patterns were analyzed. Results: From 160 samples, 47.5% (76 were culture positive cases from which 43 cases were B. melitensis and 33 were B. abortus With the PCR technique 108 were detected positive from which 45.3% were B. abortus and 54.6% were B. melitensis. It should be noted that all 76 samples with positive culture were also identified by PCR. Conclusion: Generally, use of the molecular technique multiplex PCR in addition to increased speed and accuracy and less false results than bacterial culture method, is able to identify different species of brucella. This will facilitate the treatment process.

  2. Fetal cell detection in maternal blood : A study in 236 samples using erythroblast morphology, DAB and HbF staining, and FISH analysis

    NARCIS (Netherlands)

    Oosterwijk, JC; Mesker, WE; Ouwerkerk-van Velzen, MCM; Knepfle, CFHM; Wiesmeijer, KC; Beverstock, GC; van Ommen, GJB; Kanhai, HHH; Tanke, HJ

    1998-01-01

    A protocol to detect fetal nucleated red blood cells (NRBCs) was tested in 217 pregnant women and in 19 nonpregnant controls. All the pregnant women were sampled after chorionic villus sampling (CVS); 20 were also sampled pre-CVS. NRBC recognition was based upon morphology by using staining of hemog

  3. [Accuracy of PCR for the detection of bacterial and fungal DNA in the blood and tissue samples of experimentally infected rabbits].

    Science.gov (United States)

    Fouad, Ali Adil; Kalkancı, Ayşe

    2012-10-01

    Direct demonstration of bacterial and/or fungal nucleic acids in the clinical samples of patients with blood stream infections is crucial in terms of rapid diagnosis, early and accurate therapy and patient management. This study was aimed to determine the presence of bacteria and fungi by polymerase chain reaction (PCR) in the clinical samples of experimental sepsis induced animals, to compare the results with culture and to evaluate the efficiency of PCR in the discrimination of bacteremia and fungemia. A total of 12 rabbits experimentally infected with standard strains of Staphylococcus aureus, Escherichia coli, Aspergillus fumigatus and Candida albicans to generate bacteremia (n= 4), fungemia (n= 4) and polymicrobial blood stream infection (n= 4), were included in the study. A total of 63 specimens of which 27 were blood and 36 were tissue (12 spleen, 12 liver, 12 kidney) samples were collected at 24, 48, 72 and 96th hours of infection. Uninfected healthy rabbits (n= 4), colony suspensions of standard bacterial and fungal strains (n= 15) and human blood samples contaminated with standard bacterial and fungal strains (n= 10) were used as controls. Microbial DNAs were searched by using real-time PCR in all the samples, and quantitative cultures were performed simultaneously. Gram-positive and gram-negative PCR protocols were performed for the samples of bacteremic animals, whereas panfungal PCR, Aspergillus and Candida PCR protocols were performed for the samples of animals with fungemia. All of those PCR protocols were applied separately for the samples of polymicrobial blood stream infection cases. Culture positivity was detected in 8 (29.6%) of the blood samples and bacterial and/or fungal DNAs were demonstrated in 20 (74%) of the blood samples by PCR. Microbial DNAs were also detected in 32 (89%) of 36 tissue samples (11 spleen, 11 liver, 10 kidney). Sensitivity rates of culture method to detect bacteremia and fungemia were 30% and 21.7%, respectively, whereas

  4. Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Frøslev, Tobias G; Frank-Hansen, Rune

    2011-01-01

    17025 using the Qiagen MagAttract DNA Mini M48 kit (Qiagen GmbH, Hilden, Germany) from fresh whole blood and blood from deceased individuals. The workflow was simplified by returning the DNA extracts to the original tubes minimizing the risk of misplacing samples. The tubes that originally contained...

  5. Methylation at global LINE-1 repeats in human blood are affected by gender but not by age or natural hormone cycles.

    Directory of Open Access Journals (Sweden)

    Osman El-Maarri

    Full Text Available Previously, we reported on inter-individual and gender specific variations of LINE-1 methylation in healthy individuals. In this study, we investigated whether this variability could be influenced by age or sex hormones in humans. To this end, we studied LINE-1 methylation in vivo in blood-derived DNA from individuals aged 18 to 64 years and from young healthy females at various hormone levels during the menstrual cycle. Our results show that no significant association with age was observed. However, the previously reported increase of LINE-1 methylation in males was reconfirmed. In females, although no correlation between LINE-1 or Alu methylation and hormone levels was observed, a significant stable individual specific level of methylation was noted. In vitro results largely confirmed these findings, as neither estrogen nor dihydrotestosterone affected LINE-1 or Alu methylation in Hek293T, HUVEC, or MDA-kb2 cell lines. In contrast, a decrease in methylation was observed in estrogen-treated T47-Kbluc cell lines strongly expressing estrogen receptor. The very low expression of estrogen receptor in blood cells could explain the observed insensitivity of methylation at LINE-1 to natural hormonal variations in females. In conclusion, neither natural cycle of hormones nor age has a detectable effect on the LINE-1 methylation in peripheral blood cells, while gender remains an important factor.

  6. Measurement of thyroid hormones in donkey (Equus asinus) blood and milk: validation of ELISA kits and evaluation of sample collection, handling and storage.

    Science.gov (United States)

    Todini, Luca; Malfatti, Alessandro; Salimei, Elisabetta; Fantuz, Francesco

    2010-11-01

    Donkey's milk is well tolerated by human infants with cow's milk allergy and is useful in the treatment of human immune-related diseases and in the prevention of atherosclerosis. Thyroid hormones (TH) stimulate lactation and active triiodothyronine (T3) in colostrum and milk could take paracrine action supporting lactogenesis in the mother, and play physiological roles for the suckling offspring (systemic or within the gastrointestinal tract). The aims were to measure TH concentrations in donkey blood and milk, validate ELISA methods, evaluate the effects of sample collection and post-collection handling and the stability of TH in milk and blood serum and plasma samples. In milk and blood samples obtained from lactating jennies total concentrations of TH were assayed using competitive-type ELISA kits. Good validation results were obtained for both TH concentrations in blood serum and plasma and T3 in milk samples extracted with cold (-20°C) ethanol alkalinized (pH 9·0) with NH4OH. In most of the milk extract samples, thyroxine (T4) concentrations resulted below the sensitivity threshold. Intra- and inter-assay coefficients of variations of TH concentrations in different blood and milk samples were below 10%. Parallelism tests gave displacement lines parallel to those of the calibrators for both TH in blood serum and plasma and for T3 in milk extracts. Mean recovery rates were between 95% and 123%, but the concentration values approaching the highest calibrators were overestimated. Therefore, serum and plasma samples for T3 assay must be previously diluted with buffer. Both TH concentrations in blood serum and plasma and T3 in milk did not change during storage for up to 6 months at -20°C. In conclusion, the ELISA methods tested in the present study are suitable for determination of both TH concentrations in donkey blood samples, and for T3 measurement in milk, after extraction with cold alkaline ethanol.

  7. A polymorphism in the MSH3 mismatch repair gene is associated with the levels of somatic instability of the expanded CTG repeat in the blood DNA of myotonic dystrophy type 1 patients.

    Science.gov (United States)

    Morales, Fernando; Vásquez, Melissa; Santamaría, Carolina; Cuenca, Patricia; Corrales, Eyleen; Monckton, Darren G

    2016-04-01

    Somatic mosaicism of the expanded CTG repeat in myotonic dystrophy type 1 is age-dependent, tissue-specific and expansion-biased, contributing toward the tissue-specificity and progressive nature of the symptoms. Previously, using regression modelling of repeat instability we showed that variation in the rate of somatic expansion in blood DNA contributes toward variation in age of onset, directly implicating somatic expansion in the disease pathway. Here, we confirm these results using a larger more genetically homogenous Costa Rican DM1 cohort (p<0.001). Interestingly, we also provide evidence that supports subtle sex-dependent differences in repeat length-dependent age at onset and somatic mutational dynamics. Previously, we demonstrated that variation in the rate of somatic expansion was a heritable quantitative trait. Given the important role that DNA mismatch repair genes play in mediating expansions in mouse models, we tested for modifier gene effects with 13 DNA mismatch gene polymorphisms (one each in MSH2, PMS2, MSH6 and MLH1; and nine in MSH3). After correcting for allele length and age effects, we identified three polymorphisms in MSH3 that were associated with variation in somatic instability: Rs26279 (p=0.003); Rs1677658 (p=0.009); and Rs10168 (p=0.031). However, only the association with Rs26279 remained significant after multiple testing correction. Although we revealed a statistically significant association between Rs26279 and somatic instability, we did not detect an association with the age at onset. Individuals with the A/A genotype for Rs26279 tended to show a greater propensity to expand the CTG repeat than other genotypes. Interestingly, this SNP results in an amino acid change in the critical ATPase domain of MSH3 and is potentially functionally dimorphic. These data suggest that MSH3 is a key player in generating somatic variation in DM1 patients and further highlight MSH3 as a potential therapeutic target.

  8. Organochlorine pesticide levels in blood serum samples taken at autopsy from auto accident victims in Veracruz, Mexico.

    Science.gov (United States)

    Waliszewski, Stefan M; Carvajal, Octavio; Infanzón, Rosa M; Gómez-Arroyo, Sandra; Villalobos-Pietrini, Rafael; Trujillo, Patricia; Hart, Mary Maxwell

    2004-09-01

    Samples of human blood sera (N = 118) for the determination of organochlorine pesticide levels were obtained at autopsy from auto accident victims in Veracruz, Mexico, during the years 2000 and 2001. The presence of hexachlorobenzene (HCH), beta-hexachlorocyclohexane (beta-HCH), 2,2-bis(p-chlorophenyl)-1,1-dichloroethylene (p,p'-DDE), 1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane (p,p'-DDT), and o,p'-DDT was confirmed by gas-liquid-electron-capture detection chromatography. During the years 2000 and 2001, the respective mean levels of (a) HCB, (b) beta-HCH, (c) p,p'-DDE, (d) o,p'-DDT, (e) p,p'-DDT, and (f) total DDT were (a) 2.1 ng/ml and 1.4 ng/ml, (b) 3.0 ng/ml and 3.6 ng/ml, (c) 21.1 ng/ml and 23.8 ng/ml, (d) 1.2 ng/ml and 0.8 ng/ml, (e) 3.3 ng/ml and 2.5 ng/ml, and, finally, (f) 25.4 ng/ml and 27.1 ng/ml, respectively. High levels of persistent organochlorine pesticides were--and continue to be--present in the blood of individuals who live in Mexico. Levels of insecticide metabolites (e.g., beta-HCH, p,p'-DDE) in blood have increased during recent years (1997-2001), but levels of p,p'-DDT decreased in 2001 because the use of DDT for the control of malaria in Mexico was restricted.

  9. Improvement and Evaluation of Loop-Mediated Isothermal Amplification for Rapid Detection of Toxoplasma gondii Infection in Human Blood Samples

    Science.gov (United States)

    Sun, Xi-meng; Ji, Yong-sheng; Liu, Xian-yong; Xiang, Mei; He, Guang; Xie, Li; Suo, Jing-xia; Suo, Xun

    2017-01-01

    Loop-mediated isothermal amplification (LAMP), an attractive DNA amplification method, was developed as a valuable tool for the rapid detection of Toxoplasma gondii. In this study, species-specific LAMP primers were designed by targeting the AF146527 sequence, which was a conserved sequence of 200- to 300-fold repetitive 529 bp fragment of T.gondii. LAMP reaction system was optimized so that it could detect the minimal DNA sample such as a single tachyzoite or 10 copies of recombinant plasmid. No cross-reactivity was found when using DNA from other parasites as templates. Subsequently, a total of 200 human blood samples were directly investigated by two diagnostic methods, LAMP and conventional PCR. Fourteen of 200 (7%) samples were positive for Toxoplasma by LAMP (the primers developed in this study), whereas only 5 of 200 (2.5%) were proved positive by conventional PCR. The procedure of the LAMP assay was very simple, as the reaction would be carried out in a single tube under isothermal conditions at 64°C and the result would be read out with 1 h (as early as 35 min with loop primers). Thus, this method has the advantages of rapid amplification, simple operation, and easy detection and would be useful for rapid and reliable clinical diagnosis of acute toxoplasmosis, especially in developing countries. PMID:28056092

  10. Seroepidemiological study of human cysticercosis with blood samples collected on filter paper, in Lages, State of Santa Catarina, Brazil, 2004-2005

    Directory of Open Access Journals (Sweden)

    Maria Márcia Imenes Ishida

    2011-06-01

    Full Text Available INTRODUCTION: Human serofrequency of antibodies against Taenia solium antigens was determined and risk factors for cysticercosis transmission were identified. METHODS: Individuals (n=878 from periurban and rural locations of Lages, SC, were interviewed to gather demographic, sanitary and health information. Interviews and blood sample collections by finger prick on Whatman filter paper were performed from August 2004 to May 2005. Observation determined that 850 samples were suitable for analysis and were tested by ELISA using vesicular fluid of Taenia crassiceps heterologous antigen. To ensure the reliability of the results, 77 samples of the dried blood were matched with sera. The reactive samples were submitted to a serum confirmatory immunoblot (IB test using purified Taenia crassiceps glycoproteins. RESULTS: The ELISA results for the dried blood and serum samples were statistically consistent. ELISA was positive in 186 (21.9% out of 850 individuals. A group of 213 individuals were asked to collect vein blood for IB (186 with positive result in ELISA and 27 with inappropriate whole blood samples and 130 attended the request. The IB was positive in 29 (3.4% out of 850 individuals. A significant correlation (p = 0.0364 was determined among individuals who tested positive in the IB assay who practiced both pig rearing and kitchen gardening. CONCLUSIONS: ELISA with dried blood eluted from filter paper was suitable for cysticercosis population surveys. In Lages, human infection was associated with pig rearing and kitchen gardening. The prevalence index was compatible with other Latin American endemic areas.

  11. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    Science.gov (United States)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  12. Genetic profiling of tumours using both circulating free DNA and circulating tumour cells isolated from the same preserved whole blood sample.

    Science.gov (United States)

    Rothwell, Dominic G; Smith, Nigel; Morris, Daniel; Leong, Hui Sun; Li, Yaoyong; Hollebecque, Antoine; Ayub, Mahmood; Carter, Louise; Antonello, Jenny; Franklin, Lynsey; Miller, Crispin; Blackhall, Fiona; Dive, Caroline; Brady, Ged

    2016-04-01

    Molecular information obtained from cancer patients' blood is an emerging and powerful research tool with immense potential as a companion diagnostic for patient stratification and monitoring. Blood, which can be sampled routinely, provides a means of inferring the current genetic status of patients' tumours via analysis of circulating tumour cells (CTCs) or circulating tumour DNA (ctDNA). However, accurate assessment of both CTCs and ctDNA requires all blood cells to be maintained intact until samples are processed. This dictates for ctDNA analysis EDTA blood samples must be processed with 4 h of draw, severely limiting the use of ctDNA in multi-site trials. Here we describe a blood collection protocol that is amenable for analysis of both CTCs and ctDNA up to four days after blood collection. We demonstrate that yields of circulating free DNA (cfDNA) obtained from whole blood CellSave samples are equivalent to those obtained from conventional EDTA plasma processed within 4 h of blood draw. Targeted and genome-wide NGS revealed comparable DNA quality and resultant sequence information from cfDNA within CellSave and EDTA samples. We also demonstrate that CTCs and ctDNA can be isolated from the same patient blood sample, and give the same patterns of CNA enabling direct analysis of the genetic status of patients' tumours. In summary, our results demonstrate the utility of a simple approach that enabling robust molecular analysis of CTCs and cfDNA for genotype-directed therapies in multi-site clinical trials and represent a significant methodological improvement for clinical benefit.

  13. Facile synthesis of copper(II)-decorated magnetic particles for selective removal of hemoglobin from blood samples.

    Science.gov (United States)

    Ding, Chun; Ma, Xiangdong; Yao, Xin; Jia, Li

    2015-12-11

    In this report, the Cu(2+)-immobilized magnetic particles were prepared by a facile route and they were used as adsorbents for removal of high abundance of hemoglobin in blood based on immobilized metal affinity chromatography. Ethylenediaminetetraacetic acid modified magnetic particles (EDTA-Fe3O4) were first synthesized through a one-pot solvothermal method and then charged with copper ions. The as-prepared Cu(2+)-EDTA-Fe3O4 particles were characterized by Fourier transform infrared spectrometry, scanning electron microscopy, transmission electron microscopy