WorldWideScience

Sample records for repair turnaround time

  1. Using lean principles to improve outpatient adult infusion clinic chemotherapy preparation turnaround times.

    Science.gov (United States)

    Lamm, Matthew H; Eckel, Stephen; Daniels, Rowell; Amerine, Lindsey B

    2015-07-01

    The workflow and chemotherapy preparation turnaround times at an adult infusion clinic were evaluated to identify opportunities to optimize workflow and efficiency. A three-phase study using Lean Six Sigma methodology was conducted. In phase 1, chemotherapy turnaround times in the adult infusion clinic were examined one year after the interim goal of a 45-minute turnaround time was established. Phase 2 implemented various experiments including a five-day Kaizen event, using lean principles in an effort to decrease chemotherapy preparation turnaround times in a controlled setting. Phase 3 included the implementation of process-improvement strategies identified during the Kaizen event, coupled with a final refinement of operational processes. In phase 1, the mean turnaround time for all chemotherapy preparations decreased from 60 to 44 minutes, and a mean of 52 orders for adult outpatient chemotherapy infusions was received each day. After installing new processes, the mean turnaround time had improved to 37 minutes for each chemotherapy preparation in phase 2. In phase 3, the mean turnaround time decreased from 37 to 26 minutes. The overall mean turnaround time was reduced by 26 minutes, representing a 57% decrease in turnaround times in 19 months through the elimination of waste and the implementation of lean principles. This reduction was accomplished through increased efficiencies in the workplace, with no addition of human resources. Implementation of Lean Six Sigma principles improved workflow and efficiency at an adult infusion clinic and reduced the overall chemotherapy turnaround times from 60 to 26 minutes. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. Decreasing medication turnaround time with digital scanning technology in a canadian health region.

    Science.gov (United States)

    Neville, Heather; Nodwell, Lisa; Alsharif, Sahar

    2014-11-01

    Reducing medication turnaround time can improve efficiency, patient safety, and quality of care in the hospital setting. Digital scanning technology (DST) can be used to electronically transmit scanned prescriber orders to a pharmacy computer queue for verification and processing, which may help to improve medication turnaround time. To evaluate medication turnaround time before and after implementation of DST for all medications and for antibiotics only. Medication turnaround times were evaluated retrospectively for periods before (June 6-10, 2011) and after (September 26-30, 2011) implementation of DST at 2 hospital sites in 1 health region. Medication turnaround time was defined as the time from composition of a medication order by the prescriber to its verification by the pharmacy (phase 1) and the time from prescriber composition to administration to the patient by a nurse (total). Median turnaround times were analyzed with SPSS software using the Mann-Whitney U test. In total, 304 and 244 medication orders were audited before and after DST implementation, respectively. Median phase 1 turnaround time for all medications declined significantly, from 2 h 23 min before DST implementation to 1 h 33 min after DST implementation (p < 0.001). Antibiotics were also processed significantly faster (1 h 51 min versus 1 h 9 min, p = 0.015). However, total turnaround time for all medications did not differ significantly (5 h 15 min versus 5 h 0 min, p = 0.42). Implementation of DST was associated with a 50-min decrease in medication turnaround time for the period from when an order was prescribed to the time it was processed by the pharmacy. Regular evaluation of medication turnaround times is recommended to compare with benchmarks, to ensure that hospital standards are being met, and to measure the effects of policy changes and implementation of new technology on medication-use processes.

  3. Factors that impact turnaround time of surgical pathology specimens in an academic institution.

    Science.gov (United States)

    Patel, Samip; Smith, Jennifer B; Kurbatova, Ekaterina; Guarner, Jeannette

    2012-09-01

    Turnaround time of laboratory results is important for customer satisfaction. The College of American Pathologists' checklist requires an analytic turnaround time of 2 days or less for most routine cases and lets every hospital define what a routine specimen is. The objective of this study was to analyze which factors impact turnaround time of nonbiopsy surgical pathology specimens. We calculated the turnaround time from receipt to verification of results (adjusted for weekends and holidays) for all nonbiopsy surgical specimens during a 2-week period. Factors studied included tissue type, number of slides per case, decalcification, immunohistochemistry, consultations with other pathologists, and diagnosis. Univariate and multivariate analyses were performed. A total of 713 specimens were analyzed, 551 (77%) were verified within 2 days and 162 (23%) in 3 days or more. Lung, gastrointestinal, breast, and genitourinary specimens showed the highest percentage of cases being signed out in over 3 days. Diagnosis of malignancy (including staging of the neoplasia), consultation with other pathologists, having had a frozen section, and use of immunohistochemical stains were significantly associated with increased turnaround time in univariate analysis. Decalcification was not associated with increased turnaround time. In multivariate analysis, consultation with other pathologists, use of immunohistochemistry, diagnosis of malignancy, and the number of slides studied continued to be significantly associated with prolonged turnaround time. Our findings suggest that diagnosis of malignancy is central to significantly prolonging the turnaround time for surgical pathology specimens, thus institutions that serve cancer centers will have longer turnaround time than those that do not. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Improving Reports Turnaround Time: An Essential Healthcare Quality Dimension.

    Science.gov (United States)

    Khan, Mustafa; Khalid, Parwaiz; Al-Said, Youssef; Cupler, Edward; Almorsy, Lamia; Khalifa, Mohamed

    2016-01-01

    Turnaround time is one of the most important healthcare performance indicators. King Faisal Specialist Hospital and Research Center in Jeddah, Saudi Arabia worked on reducing the reports turnaround time of the neurophysiology lab from more than two weeks to only five working days for 90% of cases. The main quality improvement methodology used was the FOCUS PDCA. Using root cause analysis, Pareto analysis and qualitative survey methods, the main factors contributing to the delay of turnaround time and the suggested improvement strategies were identified and implemented, through restructuring transcriptionists daily tasks, rescheduling physicians time and alerting for new reports, engaging consultants, consistent coordination and prioritizing critical reports. After implementation; 92% of reports are verified within 5 days compared to only 6% before implementation. 7% of reports were verified in 5 days to 2 weeks and only 1% of reports needed more than 2 weeks compared to 76% before implementation.

  5. Discrepancies Between Planned and Actual Operating Room Turnaround Times at a Large Rural Hospital in Germany

    Directory of Open Access Journals (Sweden)

    Regula Morgenegg

    2018-01-01

    retrospective study examined the OR turnaround data of 875 elective surgery cases scheduled at the Marienhospital, Vechta, Germany, between July and October 2014. The frequency distributions of planned and actual OR turnaround times were compared and correlations between turnaround times and various factors were established, including the time of day of the procedure, patient age and the planned duration of the surgery. Results: There was a significant difference between mean planned and actual OR turnaround times (0.32 versus 0.64 hours; P <0.001. In addition, significant correlations were noted between actual OR turnaround times and the time of day of the surgery, patient age, actual duration of the procedure and staffing changes affecting the surgeon or the medical specialty of the surgery (P <0.001 each. The quotient of actual/planned OR turnaround times ranged from 1.733–3.000. Conclusion: Significant discrepancies between planned and actual OR turnaround times were noted during the study period. Such findings may be potentially used in future studies to establish a tool to improve OR planning, measure OR management performance and enable benchmarking.

  6. Perceived and Real Histopathology Turnaround Time: A Teaching ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Background: This study aims to audit analytic turnaround time (TAT) in a histopathology ... facility where not only pathology services are rendered, but residency ..... pathology as a tool for quality assurance. Niger J Med. 2008 ...

  7. Decreasing laboratory turnaround time and patient wait time by implementing process improvement methodologies in an outpatient oncology infusion unit.

    Science.gov (United States)

    Gjolaj, Lauren N; Gari, Gloria A; Olier-Pino, Angela I; Garcia, Juan D; Fernandez, Gustavo L

    2014-11-01

    Prolonged patient wait times in the outpatient oncology infusion unit indicated a need to streamline phlebotomy processes by using existing resources to decrease laboratory turnaround time and improve patient wait time. Using the DMAIC (define, measure, analyze, improve, control) method, a project to streamline phlebotomy processes within the outpatient oncology infusion unit in an academic Comprehensive Cancer Center known as the Comprehensive Treatment Unit (CTU) was completed. Laboratory turnaround time for patients who needed same-day lab and CTU services and wait time for all CTU patients was tracked for 9 weeks. During the pilot, the wait time from arrival to CTU to sitting in treatment area decreased by 17% for all patients treated in the CTU during the pilot. A total of 528 patients were seen at the CTU phlebotomy location, representing 16% of the total patients who received treatment in the CTU, with a mean turnaround time of 24 minutes compared with a baseline turnaround time of 51 minutes. Streamlining workflows and placing a phlebotomy station inside of the CTU decreased laboratory turnaround times by 53% for patients requiring same day lab and CTU services. The success of the pilot project prompted the team to make the station a permanent fixture. Copyright © 2014 by American Society of Clinical Oncology.

  8. Turnaround Time and Market Capacity in Contract Cheating

    Science.gov (United States)

    Wallace, Melisa J.; Newton, Philip M.

    2014-01-01

    Contract cheating is the process whereby students auction off the opportunity for others to complete assignments for them. It is an apparently widespread yet under-researched problem. One suggested strategy to prevent contract cheating is to shorten the turnaround time between the release of assignment details and the submission date, thus making…

  9. Perceived and Real Histopathology Turnaround Time: A Teaching ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Background: This study aims to audit analytic turnaround time (TAT) in a histopathology ... TAT was 3.6 ± 2 days, with 86.7% of reports being ready within 5 working days. ... The size of the institution, extent of automation, and number of ... advocates at least 10% rescreening of cytology slides for audit ...

  10. Benchmarking, benchmarks, or best practices? Applying quality improvement principles to decrease surgical turnaround time.

    Science.gov (United States)

    Mitchell, L

    1996-01-01

    The processes of benchmarking, benchmark data comparative analysis, and study of best practices are distinctly different. The study of best practices is explained with an example based on the Arthur Andersen & Co. 1992 "Study of Best Practices in Ambulatory Surgery". The results of a national best practices study in ambulatory surgery were used to provide our quality improvement team with the goal of improving the turnaround time between surgical cases. The team used a seven-step quality improvement problem-solving process to improve the surgical turnaround time. The national benchmark for turnaround times between surgical cases in 1992 was 13.5 minutes. The initial turnaround time at St. Joseph's Medical Center was 19.9 minutes. After the team implemented solutions, the time was reduced to an average of 16.3 minutes, an 18% improvement. Cost-benefit analysis showed a potential enhanced revenue of approximately $300,000, or a potential savings of $10,119. Applying quality improvement principles to benchmarking, benchmarks, or best practices can improve process performance. Understanding which form of benchmarking the institution wishes to embark on will help focus a team and use appropriate resources. Communicating with professional organizations that have experience in benchmarking will save time and money and help achieve the desired results.

  11. Lean six sigma methodologies improve clinical laboratory efficiency and reduce turnaround times.

    Science.gov (United States)

    Inal, Tamer C; Goruroglu Ozturk, Ozlem; Kibar, Filiz; Cetiner, Salih; Matyar, Selcuk; Daglioglu, Gulcin; Yaman, Akgun

    2018-01-01

    Organizing work flow is a major task of laboratory management. Recently, clinical laboratories have started to adopt methodologies such as Lean Six Sigma and some successful implementations have been reported. This study used Lean Six Sigma to simplify the laboratory work process and decrease the turnaround time by eliminating non-value-adding steps. The five-stage Six Sigma system known as define, measure, analyze, improve, and control (DMAIC) is used to identify and solve problems. The laboratory turnaround time for individual tests, total delay time in the sample reception area, and percentage of steps involving risks of medical errors and biological hazards in the overall process are measured. The pre-analytical process in the reception area was improved by eliminating 3 h and 22.5 min of non-value-adding work. Turnaround time also improved for stat samples from 68 to 59 min after applying Lean. Steps prone to medical errors and posing potential biological hazards to receptionists were reduced from 30% to 3%. Successful implementation of Lean Six Sigma significantly improved all of the selected performance metrics. This quality-improvement methodology has the potential to significantly improve clinical laboratories. © 2017 Wiley Periodicals, Inc.

  12. [Regional pilot study to evaluate the laboratory turnaround time according to the client source].

    Science.gov (United States)

    Salinas, M; López-Garrigós, M; Yago, M; Ortuño, M; Díaz, J; Marcaida, G; Chinchilla, V; Carratala, A; Aguado, C; Rodríguez-Borja, E; Laíz, B; Guaita, M; Esteban, A; Lorente, M A; Uris, J

    2011-01-01

    To show turnaround time to client source in eight laboratories covering eight Health Areas (2,014,475 inhabitants) of the Valencian Community (Spain). Internal Laboratory Information System (LIS) registers (test register and verification date and time), and daily LIS registers were used to design the indicators, These indicators showed the percentage of key tests requested (full blood count and serum glucose and thyrotropin) that were validated on the same day the blood was taken (inpatients and Primary Care and/or at 12 a.m. (inpatients). Urgent (stat) tests were also registered as key tests (serum troponin and potassium) and were recorded in minutes. Registers were collected and indicators calculated automatically through a Data Warehouse application and OLAP cube software. Long turnaround time differences were observed at 12 a.m. in inpatients, and in the day of sample extraction in primary care patients. The variability in turnaround of stat tests is related to hospital size, activity and validation by the laboratory physician. The study results show the large turnaround time disparity in eight Health Care Areas of Valencian Community. The various requesting sources covered by the laboratories create the need for continuous mapping processes redesign and benchmarking studies to achieve customer satisfaction. Copyright © 2010 SECA. Published by Elsevier Espana. All rights reserved.

  13. Computer-aided detection system for chest radiography: reducing report turnaround times of examinations with abnormalities.

    Science.gov (United States)

    Kao, E-Fong; Liu, Gin-Chung; Lee, Lo-Yeh; Tsai, Huei-Yi; Jaw, Twei-Shiun

    2015-06-01

    The ability to give high priority to examinations with pathological findings could be very useful to radiologists with large work lists who wish to first evaluate the most critical studies. A computer-aided detection (CAD) system for identifying chest examinations with abnormalities has therefore been developed. To evaluate the effectiveness of a CAD system on report turnaround times of chest examinations with abnormalities. The CAD system was designed to automatically mark chest examinations with possible abnormalities in the work list of radiologists interpreting chest examinations. The system evaluation was performed in two phases: two radiologists interpreted the chest examinations without CAD in phase 1 and with CAD in phase 2. The time information recorded by the radiology information system was then used to calculate the turnaround times. All chest examinations were reviewed by two other radiologists and were divided into normal and abnormal groups. The turnaround times for the examinations with pathological findings with and without the CAD system assistance were compared. The sensitivity and specificity of the CAD for chest abnormalities were 0.790 and 0.697, respectively, and use of the CAD system decreased the turnaround time for chest examinations with abnormalities by 44%. The turnaround times required for radiologists to identify chest examinations with abnormalities could be reduced by using the CAD system. This system could be useful for radiologists with large work lists who wish to first evaluate the most critical studies. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Turn-around improvements

    International Nuclear Information System (INIS)

    Redaelli, S.; Venturini Delsolaro, W.

    2012-01-01

    An efficient turn-around will be an important parameter for the integrated luminosity performance at LHC in 2012, when an operation with steady beam parameters and machine configuration will be achieved at the beginning of the run. Improvements of the operational cycle were already put successfully in place after the 2010 experience but additional ways to reduce the time required to setup collisions are possible. In this paper, the 2011 turn-around performance is reviewed and the benefits of the improvements from 2010 are presented. Phases of the operational cycle when further amelioration is possible are discussed and some proposal for a faster turn-around in 2012 are outlined. (authors)

  15. A strategy for reducing turnaround time in design optimization using a distributed computer system

    Science.gov (United States)

    Young, Katherine C.; Padula, Sharon L.; Rogers, James L.

    1988-01-01

    There is a need to explore methods for reducing lengthly computer turnaround or clock time associated with engineering design problems. Different strategies can be employed to reduce this turnaround time. One strategy is to run validated analysis software on a network of existing smaller computers so that portions of the computation can be done in parallel. This paper focuses on the implementation of this method using two types of problems. The first type is a traditional structural design optimization problem, which is characterized by a simple data flow and a complicated analysis. The second type of problem uses an existing computer program designed to study multilevel optimization techniques. This problem is characterized by complicated data flow and a simple analysis. The paper shows that distributed computing can be a viable means for reducing computational turnaround time for engineering design problems that lend themselves to decomposition. Parallel computing can be accomplished with a minimal cost in terms of hardware and software.

  16. A blood-result turn-around time survey to improve congenital ...

    African Journals Online (AJOL)

    The results of a turn-around time study of blood specimens for syphilis serology in antenatal clinic attenders between 19 rural clinics and their base hospital, including a follow-up survey to assess the impact of interventions, are described. The objective of the study was to detennine how long blood samples took to get.

  17. A "Neurological Emergency Trolley" reduces turnaround time for high-risk medications in a general intensive care unit.

    Science.gov (United States)

    Ajzenberg, Henry; Newman, Paula; Harris, Gail-Anne; Cranston, Marnie; Boyd, J Gordon

    2018-02-01

    To reduce medication turnaround times during neurological emergencies, a multidisciplinary team developed a neurological emergency crash trolley in our intensive care unit. This trolley includes phenytoin, hypertonic saline and mannitol, as well as other equipment. The aim of this study was to assess whether the cart reduced turnaround times for these medications. In this retrospective cohort study, medication delivery times for two year epochs before and after its implementation were compared. Eligible patients were identified from our intensive care unit screening log. Adults who required emergent use of phenytoin, hypertonic saline or mannitol while in the intensive care unit were included. Groups were compared with nonparametric analyses. 33-bed general medical-surgical intensive care unit in an academic teaching hospital. Time to medication administration. In the pre-intervention group, there were 43 patients with 66 events. In the post-intervention group, there were 45 patients with 80 events. The median medication turnaround time was significantly reduced after implementation of the neurological emergency trolley (25 vs. 10minutes, p=0.003). There was no statistically significant difference in intensive care or 30-day survival between the two cohorts. The implementation of a novel neurological emergency crash trolley in our intensive care unit reduced medication turnaround times. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. FCC-hh turn-around cycle

    CERN Document Server

    Alemany Fernandez, Reyes; Bartmann, Wolfgang; Buffat, Xavier; Niemi, Arto; Schulte, Daniel; Solfaroli Camillocci, Matteo; Stoel, Linda

    2016-01-01

    The turn-around cycle time of a collider is defined as the time spent between the end of stable beams and the start of the next stable beams period, and its calculation is of fundamental importance. On one side it is a crucial ingredient for the computation of the optimal time spent in luminosity production, which defines the integrated luminosity per fill or store. On the other side, combined with the availability and reliability of the machine, it allows to perform a detailed breakdown of the operational performance of the collider over an operational season, i.e. percentage of time in stable beams and beam in the machine with respect to down time. This paper presents a preliminary operational cycle definition for the hadron-hadron Future Circular Collider, as a base line for estimating the corresponding turn-around time. The cycle definition is based on the Large Hadron Collider (LHC) operational cycle. Two turn-around times are presented, the theoretical one and a more realistic one based on the LHC exper...

  19. National turnaround time survey: professional consensus standards for optimal performance and thresholds considered to compromise efficient and effective clinical management.

    Science.gov (United States)

    McKillop, Derek J; Auld, Peter

    2017-01-01

    Background Turnaround time can be defined as the time from receipt of a sample by the laboratory to the validation of the result. The Royal College of Pathologists recommends that a number of performance indicators for turnaround time should be agreed with stakeholders. The difficulty is in arriving at a goal which has some evidence base to support it other than what may simply be currently achievable technically. This survey sought to establish a professional consensus on the goals and meaning of targets for laboratory turnaround time. Methods A questionnaire was circulated by the National Audit Committee to 173 lead consultants for biochemistry in the UK. The survey asked each participant to state their current target turnaround time for core investigations in a broad group of clinical settings. Each participant was also asked to provide a professional opinion on what turnaround time would pose an unacceptable risk to patient safety for each departmental category. A super majority (2/3) was selected as the threshold for consensus. Results The overall response rate was 58% ( n = 100) with a range of 49-72% across the individual Association for Clinical Biochemistry and Laboratory Medicine regions. The consensus optimal turnaround time for the emergency department was 2 h considered unacceptable. The times for general practice and outpatient department were 48 h and for Wards 12 h, respectively. Conclusions We consider that the figures provide a useful benchmark of current opinion, but clearly more empirical standards will have to develop alongside other aspects of healthcare delivery.

  20. Identifying causes of laboratory turnaround time delay in the emergency department.

    Science.gov (United States)

    Jalili, Mohammad; Shalileh, Keivan; Mojtahed, Ali; Mojtahed, Mohammad; Moradi-Lakeh, Maziar

    2012-12-01

    Laboratory turnaround time (TAT) is an important determinant of patient stay and quality of care. Our objective is to evaluate laboratory TAT in our emergency department (ED) and to generate a simple model for identifying the primary causes for delay. We measured TATs of hemoglobin, potassium, and prothrombin time tests requested in the ED of a tertiary-care, metropolitan hospital during a consecutive one-week period. The time of different steps (physician order, nurse registration, blood-draw, specimen dispatch from the ED, specimen arrival at the laboratory, and result availability) in the test turnaround process were recorded and the intervals between these steps (order processing, specimen collection, ED waiting, transit, and within-laboratory time) and total TAT were calculated. Median TATs for hemoglobin and potassium were compared with those of the 1990 Q-Probes Study (25 min for hemoglobin and 36 min for potassium) and its recommended goals (45 min for 90% of tests). Intervals were compared according to the proportion of TAT they comprised. Median TATs (170 min for 132 hemoglobin tests, 225 min for 172 potassium tests, and 195.5 min for 128 prothrombin tests) were drastically longer than Q-Probes reported and recommended TATs. The longest intervals were ED waiting time and order processing.  Laboratory TAT varies among institutions, and data are sparse in developing countries. In our ED, actions to reduce ED waiting time and order processing are top priorities. We recommend utilization of this model by other institutions in settings with limited resources to identify their own priorities for reducing laboratory TAT.

  1. Laboratory Tests Turnaround Time in Outpatient and Emergency Patients in Nigeria: Results of A Physician Survey on Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Bolodeoku J

    2017-05-01

    Full Text Available Laboratory analytical turnaround time is a well-recognised indicator of how well a laboratory is performing and is sometimes regarded as the benchmark for laboratory performance. Methods: Total 104 doctors in public and private health institutions in Nigeria, spread across all six geo-political zones participated in survey requesting information on their experience with laboratory turnaround times in emergency situations (emergency room, special care baby unit, intensive care unit, dialysis unit and outpatient situations (general medicine and diabetes. Results: The average turnaround time in hours was 5.12, 8.35, 7.32 and 8.33 for the emergency room, special care baby unit, intensive care unit and dialysis unit, respectively. For the outpatient situations, the average turnaround time in hours was 10.74 and 15.70 hours for the diabetes and general medical outpatients. The median range (hours and modal range (hours for: the emergency room was 2-4 and <2; the special care baby unit was 4-8 and 4-8; the intensive care unit was 2-4 and 2-4; the dialysis unit was 4-8 and 4-8. The median range (hours and modal range (hours for: the general outpatient clinic was 12-24 and 12-24; the diabetic clinic was 4-8 and 12-24 hours. Conclusion: These turnaround time results are quite consistent with published data from other countries. However, there is some measure of improvement that is required in some areas to reduce the laboratory turnaround in the emergency situations. This could be overcome with the introduction of more point of care testing devices into emergency units.

  2. Decreasing Histology Turnaround Time Through Stepwise Innovation and Capacity Building in Rwanda

    Directory of Open Access Journals (Sweden)

    Gaspard Muvugabigwi

    2017-11-01

    Full Text Available Purpose: Minimal turnaround time for pathology results is crucial for highest-quality patient care in all settings, especially in low- and middle-income countries, where rural populations may have limited access to health care. Methods: We retrospectively determined the turnaround times (TATs for anatomic pathology specimens, comparing three different modes of operation that occurred throughout the development and implementation of our pathology laboratory at the Butaro Cancer Center of Excellence in Rwanda. Before opening this laboratory, TAT was measured in months because of inconsistent laboratory operations and a paucity of in-country pathologists. Results: We analyzed 2,514 individual patient samples across the three modes of study. Diagnostic mode 1 (samples sent out of the country for analysis had the highest median TAT, with an overall time of 30 days (interquartile range [IQR], 22 to 43 days. For diagnostic mode 2 (static image telepathology, the median TAT was 14 days (IQR, 7 to 27 days, and for diagnostic mode 3 (onsite expert diagnosis, it was 5 days (IQR, 2 to 9 days. Conclusion: Our results demonstrate that telepathology is a significant improvement over external expert review and can greatly assist sites in improving their TATs until pathologists are on site.

  3. Reduction in laboratory turnaround time decreases emergency room length of stay

    Directory of Open Access Journals (Sweden)

    Kaushik N

    2018-04-01

    Full Text Available Nitin Kaushik,1 Victor S Khangulov,2 Matthew O’Hara,2 Ramy Arnaout3,4 1Becton, Dickinson and Company, Franklin Lakes, NJ, USA; 2Department of Health Economics and Outcomes Research, Boston Strategic Partners, Inc., Boston, MA, USA; 3Department of Pathology, 4Division of Biomedical Informatics, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA USA Objective: Laboratory tests are an important contributor to treatment decisions in the emergency department (ED. Rapid turnaround of laboratory tests can optimize ED throughout by reducing the length of stay (LOS and improving patient outcomes. Despite evidence supporting the effect of shorter turnaround time (TAT on LOS and outcomes, there is still a lack of large retrospective studies examining these associations. Here, we evaluated the effect of a reduction in laboratory TAT on ED LOS using retrospective analysis of Electronic Health Records (EHR. Materials and methods: Retrospective analysis of ED encounters from a large, US-based, de-identified EHR database and a separate analysis of ED encounters from the EHR of an ED at a top-tier tertiary care center were performed. Additionally, an efficiency model calculating the cumulative potential LOS time savings and resulting financial opportunity due to laboratory TAT reduction was created, assuming other factors affecting LOS are constant. Results: Multivariate regression analysis of patients from the multisite study showed that a 1-minute decrease in laboratory TAT was associated with 0.50 minutes of decrease in LOS. The single-site analysis confirmed our findings from the multisite analysis that a positive correlation between laboratory TAT and ED LOS exists in the ED population as a whole, as well as across different patient acuity levels. In addition, based on the calculations from the efficiency model, for a 5-, 10- and 15-minute TAT reduction, the single-site ED can potentially admit a total of 127, 256 and 386 additional

  4. Building a new predictor for multiple linear regression technique-based corrective maintenance turnaround time.

    Science.gov (United States)

    Cruz, Antonio M; Barr, Cameron; Puñales-Pozo, Elsa

    2008-01-01

    This research's main goals were to build a predictor for a turnaround time (TAT) indicator for estimating its values and use a numerical clustering technique for finding possible causes of undesirable TAT values. The following stages were used: domain understanding, data characterisation and sample reduction and insight characterisation. Building the TAT indicator multiple linear regression predictor and clustering techniques were used for improving corrective maintenance task efficiency in a clinical engineering department (CED). The indicator being studied was turnaround time (TAT). Multiple linear regression was used for building a predictive TAT value model. The variables contributing to such model were clinical engineering department response time (CE(rt), 0.415 positive coefficient), stock service response time (Stock(rt), 0.734 positive coefficient), priority level (0.21 positive coefficient) and service time (0.06 positive coefficient). The regression process showed heavy reliance on Stock(rt), CE(rt) and priority, in that order. Clustering techniques revealed the main causes of high TAT values. This examination has provided a means for analysing current technical service quality and effectiveness. In doing so, it has demonstrated a process for identifying areas and methods of improvement and a model against which to analyse these methods' effectiveness.

  5. Analysis of high-level radioactive slurries as a method to reduce DWPF turnaround times

    International Nuclear Information System (INIS)

    Coleman, C.J.; Bibler, N.E.; Ferrara, D.M.; Hay, M.S.

    1996-01-01

    Analysis of Defense Waste Processing Facility (DWPF) samples as slurries rather than as dried or vitrified samples is an effective way to reduce sample turnaround times. Slurries can be dissolved with a mixture of concentrated acids to yield solutions for elemental analysis by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Slurry analyses can be performed in eight hours, whereas analyses of vitrified samples require up to 40 hours to complete. Analyses of melter feed samples consisting of the DWPF borosilicate frit and either simulated or actual DWPF radioactive sludge were typically within a range of 3--5% of the predicted value based on the relative amounts of sludge and frit added to the slurry. The results indicate that the slurry analysis approach yields analytical accuracy and precision competitive with those obtained from analyses of vitrified samples. Slurry analyses offer a viable alternative to analyses of solid samples as a simple way to reduce analytical turnaround times

  6. Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics.

    Science.gov (United States)

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    Almost thirty years of systematic analysis have proven the turnaround time to be a fundamental dimension for the clinical laboratory. Several indicators are to date available to assess and report quality with respect to timeliness, but they sometimes lack the communicative immediacy and accuracy. The six sigma is a paradigm developed within the industrial domain for assessing quality and addressing goal and issues. The sigma level computed through the Z-score method is a simple and straightforward tool which delivers quality by a universal dimensionless scale and allows to handle non-normal data. Herein we report our preliminary experience in using the sigma level to assess the change in urgent (STAT) test turnaround time due to the implementation of total automation. We found that the Z-score method is a valuable and easy to use method for assessing and communicating the quality level of laboratory timeliness, providing a good correspondence with the actual change in efficiency which was retrospectively observed.

  7. A point-of-care chemistry test for reduction of turnaround and clinical decision time.

    Science.gov (United States)

    Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul

    2011-06-01

    Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P CLT group (46, 33-61 versus 86, 68-107 minutes; P CLT group (P CLT. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Corporate Turnarounds in the High-tech Industry in UK

    OpenAIRE

    Xiao, Haixia

    2009-01-01

    Prior research on corporate turnaround relates to those organizations that have managed to move from poor performance to high performance within a relatively short time period by a case-study approach. The study also explores the role of leadership as a key factor in making turnaround successful as characterized by the change in CEO and in the board of directors. Finally, it explores the incentive systems of those firms during the turnaround. This study analyzed six public companies whic...

  9. Predicting turnaround time reductions of the diagnostic track in the histopathology laboratory using mathematical modelling

    NARCIS (Netherlands)

    Leeftink, A G; Boucherie, R J; Hans, E W; Verdaasdonk, M A M; Vliegen, I M H; van Diest, P J

    BACKGROUND: Pathology departments face a growing volume of more and more complex testing in an era where healthcare costs tend to explode and short turnaround times (TATs) are expected. In contrast, the histopathology workforce tends to shrink, so histopathology employees experience high workload

  10. Predicting turnaround time reductions of the diagnostic track in the histopathology laboratory using mathematical modelling

    NARCIS (Netherlands)

    Leeftink, Anne Greetje; Boucherie, Richardus J.; Hans, Elias W.; Verdaasdonk, M.A.M.; Vliegen, Ingrid; Van Diest, P.J

    Background Pathology departments face a growing volume of more and more complex testing in an era where healthcare costs tend to explode and short turnaround times (TATs) are expected. In contrast, the histopathology workforce tends to shrink, so histopathology employees experience high workload

  11. External Quality Assessment of stat test intralaboratory turnaround times. Pilot study from the Members of the Working Group for the Standardization and Promotion of Turnaround Time Control under the Auspices of the Comitato Italiano per la Standardizzazione dei Metodi Ematologici e di Laboratorio.

    Science.gov (United States)

    Negri, M; Carraro, P; Caenaro, G; Cappelletti, P; Giavarina, D; Mezzena, G; Prandini, B; Rampoldi, E; Siviero, F

    1998-11-01

    We describe procedures, results and prospects of a pilot program in External Quality Assessment (EQA) of the stat test intralaboratory turnaround times. Our goals are to promote quality by systematic monitoring and comparison of performances by laboratories, continuous investigation into the state of the art of the processes from receipt of sample to transmission of results and creation of a data base for standardization of measures and definition of consensus values for turnaround time. Of 30 laboratories invited to participate, 25 took part, agreeing to record times of arrival and transmission for all determinations of three analytes (blood hemoglobin, serum/plasma potassium and plasma prothrombin time) for seven consecutive days and to continue for one or more further periods of seven days as necessary if there were less than 300 determinations for each analyte. Within a preset time limit, data were sent by e-mail on an Excel file and we sent back two reports per analyte, showing: i) the graph for time vs. percentage of tests completed and several measures of turnaround time; ii) results of all laboratories in graph form, allowing each laboratory to identify only its own data. The high proportion of participating laboratories among those invited (83%) encourages us to implement the EQA program systematically, on a half-yearly basis, extending it to all laboratories wishing to participate in Italy or elsewhere in Europe.

  12. Challenge energy policy turnaround; Herausforderung Energiewende

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Michael; Brandt-Schwabedissen, Annette; Graaff, Rudolf; Queitsch, Peter; Thomas, Roland [Staedte- und Gemeindebund Nordrhein-Westfalen e.V., Duesseldorf (Germany); Becker, Sven [Trianel GmbH, Aachen (Germany); Portz, Norbert; Schmitz, Johannes [Deutscher Staedte- und Gemeindebund, Berlin (Germany)

    2011-07-01

    The documentation under consideration makes suggestions to cities and communities in light of the energy policy turnaround. The documentation contains the following contributions: (1) Power generation by means of renewable energy resources (Johannes Schmitz); (2) The energy policy turnaround needs acceptance - communication as the key to success (Sven Becker); (3) Climate-conscious communal construction planning (Michael Becker); (4) Establishment of climate concepts (Peter Queitsch); (5) Energetic measures at buildings (Annette Brandt-Schwabedissen); (6) Energy political turnaround and awarding (Norbert Portz); (7) Electromobility (Roland Thomas); (8) Position paper of DStB for the energy policy turnaround.

  13. Maximizing value for planned maintenance and turnarounds

    Energy Technology Data Exchange (ETDEWEB)

    Crager, John [Asset Performance Canada, ULC (Canada)

    2011-07-01

    In this presentation, Asset Performance Canada elaborates on turnaround management, and provides insight into managing strategies and risks associated with turnaround processes. Value is created fast as turnarounds progress from the strategy and scope definition phases towards the planning and execution phases. Turnarounds employ best practice solutions through common processes proven effective by data, research, and experience, ensuring consistent value creation, performance tracking, and shared lesson-learning. Adherence to the turnaround work process by carefully selected planning team members with clearly defined responsibilities and expectations, as well as an effective process for scope collection and management, are crucial to turnaround success. Further to this, a formal risk management process, employing automated risk tracking software and a safety management plan for assessing risks and their severity is also invaluable in avoiding any additional costs and schedule delays. Finally, assessment of team readiness and alignment through use of the turnaround readiness index, and rapid management of discovery work, can aid in contingency management.

  14. TURNAROUND COORDINATOR. YES OR NOT?

    Directory of Open Access Journals (Sweden)

    Martin HROMÁDKA

    2013-12-01

    Full Text Available Both low cost carriers ‘fresh wind’ and liberalisation of ground handling market makes airlines to be cost-wise in every single field. Thus, ground handling contract are cutting down in terms of their costs. Handling companies struggle with pressure being put from the market environment, they rush 25 minutes turnaround with couple of people. This can be potentially dangerous from the safety point of view. One of possible solutions seems to be introducing turnaround coordinator, person who would supervise the ramp handling procedures. This paper discusses the role of turnaround coordinator within the aircraft turnaround process. Duties and responsibilities of this person are described. However, not every airport is staffing this position. The survey shows that smaller airports pay much more attention to this issue than the big ones.

  15. Efficiency of performing pulmonary procedures in a shared endoscopy unit: procedure time, turnaround time, delays, and procedure waiting time.

    Science.gov (United States)

    Verma, Akash; Lee, Mui Yok; Wang, Chunhong; Hussein, Nurmalah B M; Selvi, Kalai; Tee, Augustine

    2014-04-01

    The purpose of this study was to assess the efficiency of performing pulmonary procedures in the endoscopy unit in a large teaching hospital. A prospective study from May 20 to July 19, 2013, was designed. The main outcome measures were procedure delays and their reasons, duration of procedural steps starting from patient's arrival to endoscopy unit, turnaround time, total case durations, and procedure wait time. A total of 65 procedures were observed. The most common procedure was BAL (61%) followed by TBLB (31%). Overall procedures for 35 (53.8%) of 65 patients were delayed by ≥ 30 minutes, 21/35 (60%) because of "spillover" of the gastrointestinal and surgical cases into the time block of pulmonary procedure. Time elapsed between end of pulmonary procedure and start of the next procedure was ≥ 30 minutes in 8/51 (16%) of cases. In 18/51 (35%) patients there was no next case in the room after completion of the pulmonary procedure. The average idle time of the room after the end of pulmonary procedure and start of next case or end of shift at 5:00 PM if no next case was 58 ± 53 minutes. In 17/51 (33%) patients the room's idle time was >60 minutes. A total of 52.3% of patients had the wait time >2 days and 11% had it ≥ 6 days, reason in 15/21 (71%) being unavailability of the slot. Most pulmonary procedures were delayed due to spillover of the gastrointestinal and surgical cases into the block time allocated to pulmonary procedures. The most common reason for difficulty encountered in scheduling the pulmonary procedure was slot unavailability. This caused increased procedure waiting time. The strategies to reduce procedure delays and turnaround times, along with improved scheduling methods, may have a favorable impact on the volume of procedures performed in the unit thereby optimizing the existing resources.

  16. Combining Quick-Turnaround and Batch Workloads at Scale

    Science.gov (United States)

    Matthews, Gregory A.

    2012-01-01

    NAS uses PBS Professional to schedule and manage the workload on Pleiades, an 11,000+ node 1B cluster. At this scale the user experience for quick-turnaround jobs can degrade, which led NAS initially to set up two separate PBS servers, each dedicated to a particular workload. Recently we have employed PBS hooks and scheduler modifications to merge these workloads together under one PBS server, delivering sub-1-minute start times for the quick-turnaround workload, and enabling dynamic management of the resources set aside for that workload.

  17. Discrete time analysis of a repairable machine

    OpenAIRE

    Alfa, Attahiru Sule; Castro, I. T.

    2002-01-01

    We consider, in discrete time, a single machine system that operates for a period of time represented by a general distribution. This machine is subject to failures during operations and the occurrence of these failures depends on how many times the machine has previously failed. Some failures are repairable and the repair times may or may not depend on the number of times the machine was previously repaired. Repair times also have a general distribution. The operating times...

  18. Real time application of whole genome sequencing for outbreak investigation - What is an achievable turnaround time?

    Science.gov (United States)

    McGann, Patrick; Bunin, Jessica L; Snesrud, Erik; Singh, Seema; Maybank, Rosslyn; Ong, Ana C; Kwak, Yoon I; Seronello, Scott; Clifford, Robert J; Hinkle, Mary; Yamada, Stephen; Barnhill, Jason; Lesho, Emil

    2016-07-01

    Whole genome sequencing (WGS) is increasingly employed in clinical settings, though few assessments of turnaround times (TAT) have been performed in real-time. In this study, WGS was used to investigate an unfolding outbreak of vancomycin resistant Enterococcus faecium (VRE) among 3 patients in the ICU of a tertiary care hospital. Including overnight culturing, a TAT of just 48.5 h for a comprehensive report was achievable using an Illumina Miseq benchtop sequencer. WGS revealed that isolates from patient 2 and 3 differed from that of patient 1 by a single nucleotide polymorphism (SNP), indicating nosocomial transmission. However, the unparalleled resolution provided by WGS suggested that nosocomial transmission involved two separate events from patient 1 to patient 2 and 3, and not a linear transmission suspected by the time line. Rapid TAT's are achievable using WGS in the clinical setting and can provide an unprecedented level of resolution for outbreak investigations. Published by Elsevier Inc.

  19. Progress Report 2013. Turnaround Arts Initiative

    Science.gov (United States)

    Stoelinga, Sara Ray; Joyce, Katie; Silk, Yael

    2013-01-01

    This interim progress report provides a look at Turnaround Arts schools in their first year, including: (1) a summary of the evaluation design and research questions; (2) a preliminary description of strategies used to introduce the arts in Turnaround Arts schools; and (3) a summary of school reform indicators and student achievement data at…

  20. Hospital turnaround strategies.

    Science.gov (United States)

    Langabeer, James

    2008-01-01

    Despite reports of higher profitability in recent years, hospitals are failing at a faster rate than ever before. Although many hospitals leave decisions regarding revenues and costs to chief financial officers and their staff, this is a recipe for disaster. From research conducted over the last 4 years on hospital bankruptcies and turnarounds, the author found that a common series of actions will help organizations evade collapse. The author explored these turnaround strategies through research and analysis of a variety of hospitals and health systems that had a high probability of immediate financial crisis or collapse. His continued observation and analysis of these hospitals in subsequent years showed that most hospitals never emerge from their bleak financial conditions. However, a few hospital administrations have successfully turned around their organizations.

  1. Improving Autopsy Report Turnaround Times by Implementing Lean Management Principles.

    Science.gov (United States)

    Cromwell, Susan; Chiasson, David A; Cassidy, Debra; Somers, Gino R

    2018-01-01

    The autopsy is an integral part of the service of a large academic pathology department. Timely reporting is central to providing good service and is beneficial for many stakeholders, including the families, the clinical team, the hospital, and the wider community. The current study aimed to improve hospital-consented autopsy reporting times (turnaround time, TAT) by using lean principles modified for a healthcare setting, with an aim of signing out 90% of autopsies in 90 days. An audit of current and historical TATs was performed, and a working group incorporating administrative, technical, and professional staff constructed a value stream map documenting the steps involved in constructing an autopsy report. Two areas of delay were noted: examination of the microscopy and time taken to sign-out the report after the weekly autopsy conference. Several measures were implemented to address these delays, including visual tracking using a whiteboard and individualized tracking sheets, weekly whiteboard huddles, and timelier scheduling of clinicopathologic conference rounds. All measures resulted in an improvement of TATs. In the 30 months prior to the institution of lean, 37% of autopsies (53/144) were signed out in 90 days, with a wide variation in reporting times. In the 30 months following the institution of lean, this improved to 74% (136/185) ( P lean; 63 days post-lean). The application of lean principles to autopsy sign-out workflow can significantly improve TATs and reduce variability, without changing staffing levels or significantly altering scheduling structure.

  2. Identification of blood culture isolates directly from positive blood cultures by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry and a commercial extraction system: analysis of performance, cost, and turnaround time.

    Science.gov (United States)

    Lagacé-Wiens, Philippe R S; Adam, Heather J; Karlowsky, James A; Nichol, Kimberly A; Pang, Paulette F; Guenther, Jodi; Webb, Amanda A; Miller, Crystal; Alfa, Michelle J

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.

  3. Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

    Science.gov (United States)

    Chauhan, Aakash; Schimoler, Patrick; Miller, Mark C; Kharlamov, Alexander; Merrell, Gregory A; Palmer, Bradley A

    2018-05-01

    The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.

  4. Metas' turnaround case: a study about the turnaround strategies and the related decision streams shaping them

    OpenAIRE

    Tüzüner, Tolga

    1995-01-01

    Ankara : The Department of Business Administration of Bilkent Univ., 1995. Thesis (Master's) -- Bilkent University, 1995. Includes bibliographical references. Meta§ which is the first private steel factory with arc furnace technology, begins to implement the “turnaround” strategy during the 90’s. This case aims to determine the reasons that cause the turnaround strategy and the strategic decision streams through the turnaround. Meta$ could not succeed financially in the e...

  5. Testing ΛCDM cosmology at turnaround: where to look for violations of the bound?

    International Nuclear Information System (INIS)

    Tanoglidis, D.; Pavlidou, V.; Tomaras, T.N.

    2015-01-01

    In ΛCDM cosmology, structure formation is halted shortly after dark energy dominates the mass/energy budget of the Universe. A manifestation of this effect is that in such a cosmology the turnaround radius—the non-expanding mass shell furthest away from the center of a structure— has an upper bound. Recently, a new, local, test for the existence of dark energy in the form of a cosmological constant was proposed based on this turnaround bound. Before designing an experiment that, through high-precision determination of masses and —independently— turnaround radii, will challenge ΛCDM cosmology, we have to answer two important questions: first, when turnaround-scale structures are predicted to be close enough to their maximum size, so that a possible violation of the bound may be observable. Second, which is the best mass scale to target for possible violations of the bound. These are the questions we address in the present work. Using the Press-Schechter formalism, we find that turnaround structures have in practice already stopped forming, and consequently, the turnaround radius of structures must be very close to the maximum value today. We also find that the mass scale of ∼ 10 13  M ⊙ characterizes the turnaround structures that start to form in a statistically important number density today —and even at an infinite time in the future, since structure formation has almost stopped. This mass scale also separates turnaround structures with qualitatively different cosmological evolution: smaller structures are no longer readjusting their mass distribution inside the turnaround scale, they asymptotically approach their ultimate abundance from higher values, and they are common enough to have, at some epoch, experienced major mergers with structures of comparable mass; larger structures exhibit the opposite behavior. We call this mass scale the transitional mass scale and we argue that it is the optimal for the purpose outlined above. As a corollary

  6. A new incomplete-repair model based on a ''reciprocal-time'' pattern of sublethal damage repair

    International Nuclear Information System (INIS)

    Dale, R.G.; Fowler, J.F.

    1999-01-01

    A radiobiological model for closely spaced non-instantaneous radiation fractions is presented, based on the premise that the time process of sublethal damage (SLD) repair is 'reciprocal-time' (second order), rather than exponential (first order), in form. The initial clinical implications of such an incomplete-repair model are assessed. A previously derived linear-quadratic-based model was revised to take account of the possibility that SLD may repair with time such that the fraction of an element of initial damage remaining at time t is given as 1/(1+zt), where z is an appropriate rate constant; z is the reciprocal of the first half-time (τ) of repair. The general equation so derived for incomplete repair is applicable to all types of radiotherapy delivered at high, low and medium dose-rate in fractions delivered at regular time intervals. The model allows both the fraction duration and interfraction intervals to vary between zero and infinity. For any given value of z, reciprocal repair is associated with an apparent 'slowing-down' in the SLD repair rate as treatment proceeds. The instantaneous repair rates are not directly governed by total dose or dose per fraction, but are influenced by the treatment duration and individual fraction duration. Instantaneous repair rates of SLD appear to be slower towards the end of a continuous treatment, and are also slower following 'long' fractions than they are following 'short' fractions. The new model, with its single repair-rate parameter, is shown to be capable of providing a degree of quantitative explanation for some enigmas that have been encountered in clinical studies. A single-component reciprocal repair process provides an alternative explanation for the apparent existence of a range of repair rates in human tissues, and which have hitherto been explained by postulating the existence of a multi-exponential repair process. The build-up of SLD over extended treatments is greater than would be inferred using a

  7. Laboratory sample turnaround times: do they cause delays in the ED?

    Science.gov (United States)

    Gill, Dipender; Galvin, Sean; Ponsford, Mark; Bruce, David; Reicher, John; Preston, Laura; Bernard, Stephani; Lafferty, Jessica; Robertson, Andrew; Rose-Morris, Anna; Stoneham, Simon; Rieu, Romelie; Pooley, Sophie; Weetch, Alison; McCann, Lloyd

    2012-02-01

    Blood tests are requested for approximately 50% of patients attending the emergency department (ED). The time taken to obtain the results is perceived as a common reason for delay. The objective of this study was therefore to investigate the turnaround time (TAT) for blood results and whether this affects patient length of stay (LOS) and to identify potential areas for improvement. A time-in-motion study was performed at the ED of the John Radcliffe Hospital (JRH), Oxford, UK. The duration of each of the stages leading up to receipt of 101 biochemistry and haematology results was recorded, along with the corresponding patient's LOS. The findings reveal that the mean time for haematology results to become available was 1 hour 6 minutes (95% CI: 29 minutes to 2 hours 13 minutes), while biochemistry samples took 1 hour 42 minutes (95% CI: 1 hour 1 minute to 4 hours 21 minutes), with some positive correlation noted with the patient LOS, but no significant variation between different days or shifts. With the fastest 10% of samples being reported within 35 minutes (haematology) and 1 hour 5 minutes (biochemistry) of request, our study showed that delays can be attributable to laboratory TAT. Given the limited ability to further improve laboratory processes, the solutions to improving TAT need to come from a collaborative and integrated approach that includes strategies before samples reach the laboratory and downstream review of results. © 2010 Blackwell Publishing Ltd.

  8. "Turnaround" as Shock Therapy: Race, Neoliberalism, and School Reform

    Science.gov (United States)

    Johnson, Amanda Walker

    2013-01-01

    "Turnaround" strategies of educational reform promise that school closure, reconstitution, privatizing, and reopening them will bring miraculous results. Questioning the implications, this article situates "turnaround" strategies locally, following the closure of a predominantly minority high school in 2008, in Austin, Texas.…

  9. Enquiry time as part of turnaround time: when do our clinicians really consult our results?

    Science.gov (United States)

    Rodríguez-Borja, Enrique; Villalba-Martínez, C; Carratalá-Calvo, A

    2014-07-01

    Traditionally, laboratories' turnaround times (TAT) have been calculated by only considering analytical or intralaboratory steps. The measure of the postanalytical impact in TAT has barely been studied and, more specifically, the running time from when finalised results are available to when clinicians make their first enquiry with an electronic medical record. During May-June of 2013, two 'Times' were collected from our laboratory information system for all the priority requests coming from our day hospitals: 'Validation time' (TV), as the request report time with full verified results and 'Enquiry time' (TQ), as the time when the first consult was made via electronic medical record. We classified requests in groups depending on time results, and TQ-TV (percentiles) were calculated for each group. 654 (69%) requests were consulted by clinicians before 15 : 00 on the same day with available results. 191 (20%) were consulted after 15 : 00 and had complete results as well (p50 (TQ-TV): 5 days) while 61 (7%) were never consulted (up to 31/12/2013). 39 (4%) requests were finally consulted before 15 : 00 h with no available results, but the average time difference between validation and enquiry was 31 min. The results obtained lead us to reconsider the TAT established with our day hospitals in order to know if priority has to be reviewed or if there are failures in follow-up results. 'Enquiry time' appears to be a powerful tool in detecting these issues and shows that TATs are no longer just a 'laboratory problem'. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Series Overview. Sustaining School Turnaround at Scale. Brief 1

    Science.gov (United States)

    Education Resource Strategies, 2012

    2012-01-01

    Members of the non-profit organization Education Resource Strategies (ERS) have worked for over a decade with leaders of urban school systems to help them organize talent, time and technology to support great schools at scale. One year into the Federal program they are noticing significant differences in district turnaround approaches, engagement…

  11. Turnaround operations analysis for OTV. Volume 2: Detailed technical report

    Science.gov (United States)

    1988-01-01

    The objectives and accomplishments were to adapt and apply the newly created database of Shuttle/Centaur ground operations. Previously defined turnaround operations analyses were to be updated for ground-based OTVs (GBOTVs) and space-based OTVs (SBOTVs), design requirements identified for both OTV and Space Station accommodations hardware, turnaround operations costs estimated, and a technology development plan generated to develop the required capabilities. Technical and programmatic data were provided for NASA pertinent to OTV round and space operations requirements, turnaround operations, task descriptions, timelines and manpower requirements, OTV modular design and booster and Space Station interface requirements. SBOTV accommodations development schedule, cost and turnaround operations requirements, and a technology development plan for ground and space operations and space-based accommodations facilities and support equipment. Significant conclusion are discussed.

  12. Component Repair Times Obtained from MSPI Data

    Energy Technology Data Exchange (ETDEWEB)

    Eide, Steven A. [Curtiss-Wright/Scietech, Ketchum, ID (United States); Cadwallader, Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    Information concerning times to repair or restore equipment to service given a failure is valuable to probabilistic risk assessments (PRAs). Examples of such uses in modern PRAs include estimation of the probability of failing to restore a failed component within a specified time period (typically tied to recovering a mitigating system before core damage occurs at nuclear power plants) and the determination of mission times for support system initiating event (SSIE) fault tree models. Information on equipment repair or restoration times applicable to PRA modeling is limited and dated for U.S. commercial nuclear power plants. However, the Mitigating Systems Performance Index (MSPI) program covering all U.S. commercial nuclear power plants provides up-to-date information on restoration times for a limited set of component types. This paper describes the MSPI program data available and analyzes the data to obtain median and mean component restoration times as well as non-restoration cumulative probability curves. The MSPI program provides guidance for monitoring both planned and unplanned outages of trains of selected mitigating systems deemed important to safety. For systems included within the MSPI program, plants monitor both train UA and component unreliability (UR) against baseline values. If the combined system UA and UR increases sufficiently above established baseline results (converted to an estimated change in core damage frequency or CDF), a “white” (or worse) indicator is generated for that system. That in turn results in increased oversight by the US Nuclear Regulatory Commission (NRC) and can impact a plant’s insurance rating. Therefore, there is pressure to return MSPI program components to service as soon as possible after a failure occurs. Three sets of unplanned outages might be used to determine the component repair durations desired in this article: all unplanned outages for the train type that includes the component of interest, only

  13. Customising turnaround time indicators to requesting clinician: a 10-year study through balanced scorecard indicators.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos

    2014-09-01

    The purpose of this study is, first to present a 10-year monitoring of postanalytical turnaround time (TAT) adapted to different clinicians and patient situations, second to evaluate and analyse the indicators results during that period of time, and finally to show a synthetic appropriate indicator to be included in the balanced scorecard management system. TAT indicator for routine samples was devised as the percentage of certain key tests that were verified before a specific time on the phlebotomy day. A weighted mean synthetic indicator was also designed. They were calculated for inpatients at 15:00 and 12:00 and for primary care patients only at 15:00. The troponin TAT of emergency department patients, calculated as the difference between the troponin verification and registration time, was selected as the stat laboratory TAT indicator. The routine and stat TAT improved along the 10-year study period. The synthetic indicator showed the same trend. The implementation of systematic and continuous monitoring over years, promoted a continuous improvement in TAT which will probably benefit patient outcome and safety.

  14. The Effect of Locus of Control on School Turnaround

    Science.gov (United States)

    Walston, Bradford

    2012-01-01

    This research focused on the school turnaround process in six turnaround elementary schools located in urban and rural areas of the state of North Carolina. The purpose of the study was to learn about the challenges facing the six schools, the process of improving student achievement, and, more specifically, the degree to which adaptive leadership…

  15. Turnaround and Sustainability in Economic Crisis: The Case of NEXT PLC

    OpenAIRE

    Zhang, Biyan

    2013-01-01

    Purpose- against a background of continued weak economic conditions and with many firms experiencing declining financial performance, this paper presents a synthesis of the business turnaround literature and combines with analysis case –NEXT plc. It purposes to discus the turnaround strategies can keep the declining firm sustainability recovery, during the economic cycle. \\ud \\ud Design/methodology/approach- the turnaround strategy for sustainability recovery are examined by a case study of N...

  16. Reasoning about repairability of workflows at design time

    NARCIS (Netherlands)

    Tagni, Gaston; Ten Teije, Annette; Van Harmelen, Frank

    2009-01-01

    This paper describes an approach for reasoning about the repairability of workflows at design time. We propose a heuristic-based analysis of a workflow that aims at evaluating its definition, considering different design aspects and characteristics that affect its repairability (called repairability

  17. Nuclear graphite ageing and turnaround

    International Nuclear Information System (INIS)

    Marsden, B.J.; Hall, G.N.; Smart, J.

    2001-01-01

    Graphite moderated reactors are being operated in many countries including, the UK, Russia, Lithuania, Ukraine and Japan. Many of these reactors will operate well into the next century. New designs of High Temperature Graphite Moderated Reactors (HTRS) are being built in China and Japan. The design life of these graphite-moderated reactors is governed by the ageing of the graphite core due to fast neutron damage, and also, in the case of carbon dioxide cooled reactors by the rate of oxidation of the graphite. Nuclear graphites are polycrystalline in nature and it is the irradiation-induced damage to the individual graphite crystals that determines the material property changes with age. The life of a graphite component in a nuclear reactor can be related to the graphite irradiation induced dimensional changes. Graphites typically shrink with age, until a point is reached where the shrinkage stops and the graphite starts to swell. This change from shrinkage to swelling is known as ''turnaround''. It is well known that pre-oxidising graphite specimens caused ''turnaround'' to be delayed, thus extending the life of the graphite, and hence the life of the reactor. However, there was no satisfactory explanation of this behaviour. This paper presents a numerical crystal based model of dimensional change in graphite, which explains the delay in ''turnaround'' in the pre-oxidised specimens irradiated in a fast neutron flux, in terms of crystal accommodation and orientation and change in compliance due to radiolytic oxidation. (author)

  18. Minimizing manual image segmentation turn-around time for neuronal reconstruction by embracing uncertainty.

    Directory of Open Access Journals (Sweden)

    Stephen M Plaza

    Full Text Available The ability to automatically segment an image into distinct regions is a critical aspect in many visual processing applications. Because inaccuracies often exist in automatic segmentation, manual segmentation is necessary in some application domains to correct mistakes, such as required in the reconstruction of neuronal processes from microscopic images. The goal of the automated segmentation tool is traditionally to produce the highest-quality segmentation, where quality is measured by the similarity to actual ground truth, so as to minimize the volume of manual correction necessary. Manual correction is generally orders-of-magnitude more time consuming than automated segmentation, often making handling large images intractable. Therefore, we propose a more relevant goal: minimizing the turn-around time of automated/manual segmentation while attaining a level of similarity with ground truth. It is not always necessary to inspect every aspect of an image to generate a useful segmentation. As such, we propose a strategy to guide manual segmentation to the most uncertain parts of segmentation. Our contributions include 1 a probabilistic measure that evaluates segmentation without ground truth and 2 a methodology that leverages these probabilistic measures to significantly reduce manual correction while maintaining segmentation quality.

  19. Component Repair Times Obtained from MSPI Data

    International Nuclear Information System (INIS)

    Eide, Steven A.; Cadwallader, Lee

    2015-01-01

    Information concerning times to repair or restore equipment to service given a failure is valuable to probabilistic risk assessments (PRAs). Examples of such uses in modern PRAs include estimation of the probability of failing to restore a failed component within a specified time period (typically tied to recovering a mitigating system before core damage occurs at nuclear power plants) and the determination of mission times for support system initiating event (SSIE) fault tree models. Information on equipment repair or restoration times applicable to PRA modeling is limited and dated for U.S. commercial nuclear power plants. However, the Mitigating Systems Performance Index (MSPI) program covering all U.S. commercial nuclear power plants provides up-to-date information on restoration times for a limited set of component types. This paper describes the MSPI program data available and analyzes the data to obtain median and mean component restoration times as well as non-restoration cumulative probability curves. The MSPI program provides guidance for monitoring both planned and unplanned outages of trains of selected mitigating systems deemed important to safety. For systems included within the MSPI program, plants monitor both train UA and component unreliability (UR) against baseline values. If the combined system UA and UR increases sufficiently above established baseline results (converted to an estimated change in core damage frequency or CDF), a ''white'' (or worse) indicator is generated for that system. That in turn results in increased oversight by the US Nuclear Regulatory Commission (NRC) and can impact a plant's insurance rating. Therefore, there is pressure to return MSPI program components to service as soon as possible after a failure occurs. Three sets of unplanned outages might be used to determine the component repair durations desired in this article: all unplanned outages for the train type that includes the component of

  20. Improvement of laboratory turnaround time using lean methodology.

    Science.gov (United States)

    Gupta, Shradha; Kapil, Sahil; Sharma, Monica

    2018-05-14

    Purpose The purpose of this paper is to discuss the implementation of lean methodology to reduce the turnaround time (TAT) of a clinical laboratory in a super speciality hospital. Delays in report delivery lead to delayed diagnosis increased waiting time and decreased customer satisfaction. The reduction in TAT will lead to increased patient satisfaction, quality of care, employee satisfaction and ultimately the hospital's revenue. Design/methodology/approach The generic causes resulting in increasing TAT of clinical laboratories were identified using lean tools and techniques such as value stream mapping (VSM), Gemba, Pareto Analysis and Root Cause Analysis. VSM was used as a tool to analyze the current state of the process and further VSM was used to design the future state with suggestions for process improvements. Findings This study identified 12 major non-value added factors for the hematology laboratory and 5 major non-value added factors for the biochemistry lab which were acting as bottlenecks resulting in limiting throughput. A four-month research study by the authors together with hospital quality department and laboratory staff members led to reduction of the average TAT from 180 to 95minutes in the hematology lab and from 268 to 208 minutes in the biochemistry lab. Practical implications Very few improvement initiatives in Indian healthcare are based on industrial engineering tools and techniques, which might be due to a lack of interaction between healthcare and engineering. The study provides a positive outcome in terms of improving the efficiency of services in hospitals and identifies a scope for lean in the Indian healthcare sector. Social implications Applying lean in the Indian healthcare sector gives its own potential solution to the problem caused, due to a wide gap between lean accessibility and lean implementation. Lean helped in changing the mindset of an organization toward providing the highest quality of services with faster delivery at

  1. German energy turnaround and Poland's start in nuclear power? A survey

    International Nuclear Information System (INIS)

    Knopp, Lothar; Gorski, Marek

    2015-01-01

    The book includes contributions from two meetings: 1. Meeting in Berlin, October 8,2014: Energy transition in Poland - historical background, development and actual situation; legal boundary conditions of the entry into nuclear power in Poland; ecologic and economic causes motivation for the atomic energy entry in Poland; promotion systems for renewable energy in Poland, current status and political background; construction of a nuclear power plant in Northern Poland site specific impacts and social assessment. Meeting in Stettin on November 5, 2014: Energy turnaround in Germany -German nuclear phaseout under consideration of EU legislation; ecologic and economic motivation for the energy turnaround in Germany; energy turnaround in Germany - new legal boundary conditions, especially the amendment to tue renewable energy law; contribution of the industry to the energy turnaround - taking the example waste management and waste incineration plants; fracking as a factor of the energy turnaround? - legal boundary conditions and ecologic risks; ecological, ethical and sociopolitical aspects of the energy turnaround in Germany and Poland.

  2. Ditching the Disc: The Effects of Cloud-Based Image Sharing on Department Efficiency and Report Turnaround Times in Mammography.

    Science.gov (United States)

    Morgan, Matthew B; Young, Elizabeth; Harada, Scott; Winkler, Nicole; Riegert, Joanna; Jones, Tony; Hu, Nan; Stein, Matthew

    2017-12-01

    In screening mammography, accessing prior examination images is crucial for accurate diagnosis and avoiding false-positives. When women visit multiple institutions for their screens, these "outside" examinations must be retrieved for comparison. Traditionally, prior images are obtained by faxing requests to other institutions and waiting for standard mail (film or CD-ROM), which can greatly delay report turnaround times. Recently, advancements in cloud-based image transfer technology have opened up more efficient options for examination transfer between institutions. The objective of this study was to evaluate the effect of cloud-based image transfer on mammography department workflow, time required to obtain prior images, and report turnaround times. Sixty screening examinations requiring prior images were placed into two groups (30 each). The control group used the standard institutional protocol for requesting prior images: faxing requests and waiting for mailed examinations. The experimental group used a cloud-based transfer for both requesting and receiving examinations. The mean number of days between examination request and examination receipt was measured for both groups and compared. The mean number of days from examination request to receipt was 6.08 days (SD 3.50) in the control group compared with 3.16 days (SD 3.95) in the experimental group. Using a cloud-based image transfer to obtain prior mammograms resulted in an average reduction of 2.92 days (P = .0361; 95% confidence interval 0.20-5.65) between examination request and receipt. This improvement in system efficiency is relevant for interpreting radiologists working to improve reporting times and for patients anxious to receive their mammography results. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Ozone impact minimization through coordinated scheduling of turnaround operations from multiple olefin plants in an ozone nonattainment area

    Science.gov (United States)

    Ge, Sijie; Wang, Sujing; Xu, Qiang; Ho, Thomas

    2018-03-01

    Turnaround operations (start-up and shutdown) are critical operations in olefin plants, which emit large quantities of VOCs, NOx and CO. The emission has great potentials to impact the ozone level in ozone nonattainment areas. This study demonstrates a novel practice to minimize the ozone impact through coordinated scheduling of turnaround operations from multiple olefin plants located in Houston, Texas, an ozone nonattainment area. The study considered two olefin plants scheduled to conduct turnaround operations: one start-up and one shutdown, simultaneously on the same day within a five-hour window. Through dynamic simulations of the turnaround operations using ASPEN Plus Dynamics and air quality simulations using CAMx, the study predicts the ozone impact from the combined effect of the two turnaround operations under different starting-time scenarios. The simulations predict that the ozone impact from planned turnaround operations ranges from a maximum of 11.4 ppb to a minimum of 1.4 ppb. Hence, a reduction of up to 10.0 ppb can be achieved on a single day based on the selected two simulation days. This study demonstrates a cost-effective and environmentally benign ozone control practice for relevant stakeholders, including environmental agencies, regional plant operators, and local communities.

  4. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    Science.gov (United States)

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  5. Defining Business decline, failure and turnaround: A content analysis

    Directory of Open Access Journals (Sweden)

    Marius Pretorius

    2009-12-01

    Full Text Available In the past, researchers have often defined failure to suit their data. This has led to a lack of comparability in research outputs. The overriding objective of this paper is to propose a universal definition for the failure phenomenon. Clear definitions are a prerequisite for exploring major constructs, their relationship to failure and the context and processes involved. The study reports on the core definitions of the failure phenomenon and identifies core criteria for distinguishing between them. It places decline, failure and turnaround in perspective and highlights level of distress and turnaround as key moderating elements. It distinguishes the failure phenomenon from controversial synonyms such as closure, accidental bankruptcy and closure for alternative motives. Key words and phrases: business decline, failure, turnaround, level of distress

  6. The big fix : fresh thinking on turnarounds could reduce downtime and costs

    International Nuclear Information System (INIS)

    Stastny, P.

    2007-01-01

    Major overhauls at oilsands processing plants were discussed. The harsh chemicals and abrasive substances used to process and refine bitumens are responsible for most of the major maintenance turnarounds required at oilsands plants. Catastrophic failures can often result in the decision to shut a plant down entirely and proceed with overhauls scheduled in the future. Control equipment is often replaced during turnarounds to further optimize processing capabilities, and many oilsands operators are now including turnarounds in their labour forecasts in order to more effectively manage their maintenance workforce. Unexpected maintenance requirements can often make planning for turnarounds problematic. Complex decision-making is often needed to balance both maintenance budgets and schedules. While many major operators are still directly managing managing turnarounds, other operators are now contracting service companies to plan and oversee major maintenance overhauls. It was concluded that contracted maintenance work can allow service companies to invest in training and maintenance technologies that may help to ensure the smooth operation of oil sands processing plants. 4 figs

  7. Making Sense of School Turnarounds

    Science.gov (United States)

    Hess, Frederick M.

    2012-01-01

    Today, in a sector flooded with $3.5 billion in School Improvement Grant funds and the resulting improvement plans, there's great faith that "turnaround" strategies are a promising way to tackle stubborn problems with persistently low-performing schools. Unlike traditional reform efforts, with their emphasis on incremental improvement, turnarounds…

  8. The time course of repair of ultraviolet-induced DNA damage; implications for the structural organization of repair

    International Nuclear Information System (INIS)

    Collins, A.; Squires, S.

    1986-01-01

    Alternative molecular mechanisms can be envisaged for the cellular repair of UV-damaged DNA. In the 'random collision' model, DNA damage distributed throughout the genome is recognised and repaired by a process of random collision between DNA damage and repair enzymes. The other model assumes a 'processive' mechanism, whereby DNA is scanned for damage by a repair complex moving steadily along its length. Random collision should result in a declining rate of repair with time as the concentration of lesions in the DNA falls; but the processive model predicts a constant rate until scanning is complete. The authors have examined the time course of DNA repair in human fibroblasts given low doses of UV light. Using 3 distinct assays, the authors find no sign of a constant repair rate after 4 J/m 2 or less, even when the first few hours after irradiation are examined. Thus DNA repair is likely to depend on random collision. (Auth.)

  9. A Probabilistic Tool that Aids Logistics Engineers in the Establishment of High Confidence Repair Need-Dates at the NASA Shuttle Logistics Depot

    Science.gov (United States)

    Bullington, J. V.; Winkler, J. C.; Linton, D. G.; Khajenoori, S.

    1995-01-01

    The NASA Shuttle Logistics Depot (NSLD) is tasked with the responsibility for repair and manufacture of Line Replaceable Unit (LRU) hardware and components to support the Space Shuttle Orbiter. Due to shrinking budgets, cost effective repair of LRU's becomes a primary objective. To achieve this objective, is imperative that resources be assigned to those LRU's which have the greatest expectation of being needed as a spare. Forecasting the times at which spares are needed requires consideration of many significant factors including: failure rate, flight rate, spares availability, and desired level of support, among others. This paper summarizes the results of the research and development work that has been accomplished in producing an automated tool that assists in the assignment of effective repair start-times for LRU's at the NSLD. This system, called the Repair Start-time Assessment System (RSAS), uses probabilistic modeling technology to calculate a need date for a repair that considers the current repair pipeline status, as well as, serviceable spares and projections of future demands. The output from the system is a date for beginning the repair that has significantly greater confidence (in the sense that a desired probability of support is ensured) than times produced using other techniques. Since an important output of RSAS is the longest repair turn-around time that will ensure a desired probability of support, RSAS has the potential for being applied to operations at any repair depot where spares are on-hand and repair start-times are of interest. In addition, RSAS incorporates tenants of Just-in-Time (JIT) techniques in that the latest repair start-time (i.e., the latest time at which repair resources must be committed) may be calculated for every failed unit This could reduce the spares inventory for certain items, without significantly increasing the risk of unsatisfied demand.

  10. Real-time polymerase chain reaction with melting analysis of positive blood culture specimens in bloodstream infections: diagnostic value and turnaround time.

    Science.gov (United States)

    Angeletti, Silvia; Gherardi, Giovanni; De Florio, Lucia; Avola, Alessandra; Crea, Francesca; Riva, Elisabetta; Vitali, Massimiliano Andrea; Galluzzo, Sara; Dicuonzo, Giordano

    2013-01-01

    A Real-time polymerase chain reaction (PCR) with melting analysis was devised to target bacterial and fungal genes together with the most prevalent antimicrobial resistance genes in 250 positive blood culture broths. This method allowed the blood culture cultivated pathogens to be classified into clinically relevant groups such as Enterobacteriaceae, oxidase-positive bacilli, oxidase-positive coccobacilli, S. aureus and yeast. Enterococci and streptococci could be distinguished from CoNS only by the Gram stain. Gram-positive bacilli were discriminated from Gram-positive cocci by Gram stain. Furthermore, the most important antimicrobial resistant genes such as mecA, vanA, bla TEM , bla SHV and bla CTX-M could be identified. All results were obtained with a turnaround time of three hours from the moment of blood culture positivity compared to 24-72 hours for phenotypic methods. In conclusion, the proposed approach can allow the clinician to implement proper early management of sepsis patients.

  11. Comparison of turnaround time and total cost of HIV testing before and after implementation of the 2014 CDC/APHL Laboratory Testing Algorithm for diagnosis of HIV infection.

    Science.gov (United States)

    Chen, Derrick J; Yao, Joseph D

    2017-06-01

    Updated recommendations for HIV diagnostic laboratory testing published by the Centers for Disease Control and Prevention and the Association of Public Health Laboratories incorporate 4th generation HIV immunoassays, which are capable of identifying HIV infection prior to seroconversion. The purpose of this study was to compare turnaround time and cost between 3rd and 4th generation HIV immunoassay-based testing algorithms for initially reactive results. The clinical microbiology laboratory database at Mayo Clinic, Rochester, MN was queried for 3rd generation (from November 2012 to May 2014) and 4th generation (from May 2014 to November 2015) HIV immunoassay results. All results from downstream supplemental testing were recorded. Turnaround time (defined as the time of initial sample receipt in the laboratory to the time the final supplemental test in the algorithm was resulted) and cost (based on 2016 Medicare reimbursement rates) were assessed. A total of 76,454 and 78,998 initial tests were performed during the study period using the 3rd generation and 4th generation HIV immunoassays, respectively. There were 516 (0.7%) and 581 (0.7%) total initially reactive results, respectively. Of these, 304 (58.9%) and 457 (78.7%) were positive by supplemental testing. There were 10 (0.01%) cases of acute HIV infection identified with the 4th generation algorithm. The most frequent tests performed to confirm an HIV-positive case using the 3rd generation algorithm, which were reactive initial immunoassay and positive HIV-1 Western blot, took a median time of 1.1 days to complete at a cost of $45.00. In contrast, the most frequent tests performed to confirm an HIV-positive case using the 4th generation algorithm, which included a reactive initial immunoassay and positive HIV-1/-2 antibody differentiation immunoassay for HIV-1, took a median time of 0.4 days and cost $63.25. Overall median turnaround time was 2.2 and 1.5 days, and overall median cost was $63.90 and $72.50 for

  12. Stochastic behavior of a cold standby system with maximum repair time

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2015-09-01

    Full Text Available The main aim of the present paper is to analyze the stochastic behavior of a cold standby system with concept of preventive maintenance, priority and maximum repair time. For this purpose, a stochastic model is developed in which initially one unit is operative and other is kept as cold standby. There is a single server who visits the system immediately as and when required. The server takes the unit under preventive maintenance after a maximum operation time at normal mode if one standby unit is available for operation. If the repair of the failed unit is not possible up to a maximum repair time, failed unit is replaced by new one. The failure time, maximum operation time and maximum repair time distributions of the unit are considered as exponentially distributed while repair and maintenance time distributions are considered as arbitrary. All random variables are statistically independent and repairs are perfect. Various measures of system effectiveness are obtained by using the technique of semi-Markov process and RPT. To highlight the importance of the study numerical results are also obtained for MTSF, availability and profit function.

  13. Energy turnaround and nuclear phaseout. Chance or meander; Energiewende und Atomausstieg. Chance oder Irrweg

    Energy Technology Data Exchange (ETDEWEB)

    Marth, Willy

    2015-07-01

    The booklet on the energy turnaround covers the following topics: ascent of the German electricity companies, early scenarios of the nuclear phase-out, the moderate energy turnaround, the controversial climatic change, Fukushima, the abrupt nuclear phase-out in Germany (2011), energy-economical problems of the abrupt energy turnaround, boom and crash of then renewable energy companies, the come-down of the German electricity companies, summary and evaluation.

  14. The timing of spontaneous detection and repair of naming errors in aphasia.

    Science.gov (United States)

    Schuchard, Julia; Middleton, Erica L; Schwartz, Myrna F

    2017-08-01

    This study examined the timing of spontaneous self-monitoring in the naming responses of people with aphasia. Twelve people with aphasia completed a 615-item naming test twice, in separate sessions. Naming attempts were scored for accuracy and error type, and verbalizations indicating detection were coded as negation (e.g., "no, not that") or repair attempts (i.e., a changed naming attempt). Focusing on phonological and semantic errors, we measured the timing of the errors and of the utterances that provided evidence of detection. The effects of error type and detection response type on error-to-detection latencies were analyzed using mixed-effects regression modeling. We first asked whether phonological errors and semantic errors differed in the timing of the detection process or repair planning. Results suggested that the two error types primarily differed with respect to repair planning. Specifically, repair attempts for phonological errors were initiated more quickly than repair attempts for semantic errors. We next asked whether this difference between the error types could be attributed to the tendency for phonological errors to have a high degree of phonological similarity with the subsequent repair attempts, thereby speeding the programming of the repairs. Results showed that greater phonological similarity between the error and the repair was associated with faster repair times for both error types, providing evidence of error-to-repair priming in spontaneous self-monitoring. When controlling for phonological overlap, significant effects of error type and repair accuracy on repair times were also found. These effects indicated that correct repairs of phonological errors were initiated particularly quickly, whereas repairs of semantic errors were initiated relatively slowly, regardless of their accuracy. We discuss the implications of these findings for theoretical accounts of self-monitoring and the role of speech error repair in learning. Copyright

  15. Turnaround strategies: Prípadová štúdia spoločnosti Yahoo!

    OpenAIRE

    Kartalová, Petra

    2013-01-01

    This bachelor thesis focuses on Marissa Mayer's turnaround strategy in Yahoo. The thesis consists of three parts. The first part deals with the theoretical concept of a turnaround. In the second part, the whole Internet Industry Provider Industry is being analysed, as well as the main reasons that led Yahoo to fall behind the competition and lose its user base. The last part of the thesis deals with the particular turnaround strategy and its four main components -- people, products, traffic a...

  16. Review of Maintenance and Repair Times for Components in Technological Facilities

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader

    2012-11-01

    This report is a compilation of some unique component repair time data and it also presents citations of more extensive reports where lists of repair times can be found. This collection of information should support analysts who seek to quantify maintainability and availability of high technology and nuclear energy production systems. While there are newer sources of repair time information, most, if not all, of the newer sources are proprietary and cannot be shared. This report offers data that, while older, is openly accessible and can serve as reasonable estimates of repair times, at least for initial studies. Some times were found for maintenance times in radiation environments, and some guidance for multiplicative factors to use to account for work in contamination areas.

  17. High mortality in HIV-infected children diagnosed in hospital underscores need for faster diagnostic turnaround time in prevention of mother-to-child transmission of HIV (PMTCT) programs.

    Science.gov (United States)

    Wagner, Anjuli; Slyker, Jennifer; Langat, Agnes; Inwani, Irene; Adhiambo, Judith; Benki-Nugent, Sarah; Tapia, Ken; Njuguna, Irene; Wamalwa, Dalton; John-Stewart, Grace

    2015-02-15

    Despite expanded programs for prevention of mother-to-child HIV transmission (PMTCT), HIV-infected infants may not be diagnosed until they are ill. Comparing HIV prevalence and outcomes in infants diagnosed in PMTCT programs to those in hospital settings may improve pediatric HIV diagnosis strategies. HIV-exposed infants turnaround time for tests were compared between PMTCT programs and hospital sites. Among the enrolled cohort, baseline characteristics, survival, and timing of antiretroviral therapy (ART) initiation were compared between infants diagnosed in PMTCT programs versus hospital. Among 1,923 HIV-exposed infants, HIV prevalence was higher among infants tested in hospital than PMTCT early infant diagnosis (EID) sites (41% vs. 11%, p 3 times as likely to die (HR = 3.1, 95% CI = 1.3-7.6). Among HIV-exposed infants, hospital-based testing was more likely to detect an HIV-infected infant than PMTCT testing. Because young symptomatic infants diagnosed with HIV during hospitalization have very high mortality, every effort should be made to diagnose HIV infections before symptom onset. Systems to expedite turnaround time at PMTCT EID sites and to routinize inpatient pediatric HIV testing are necessary to improve pediatric HIV outcomes.

  18. Factors associated with long turnaround time for early infant diagnosis of HIV in Myanmar.

    Science.gov (United States)

    Thiha, Soe; Shewade, Hemant Deepak; Philip, Sairu; Aung, Thet Ko; Kyaw, Nang Thu Thu; Oo, Myo Minn; Kyaw, Khine Wut Yee; Wint War, May; Oo, Htun Nyunt

    2017-01-01

    A previous review of early infant diagnosis (EID) using polymerase chain reaction technology (PCR) under integrated HIV care (IHC) program in Myanmar revealed a low uptake of timely (within 6 to 8 weeks of babies' age) EID and a long turnaround time (TAT) of receiving results. This study aimed to determine the proportion and factors associated with the composite outcome of a long TAT (≥7 weeks; from sample collection to receipt of result by mother) or nonreceipt of result among HIV-exposed babies whose blood samples were collected for PCR at mother's CD4 count of 100-350 cells/mm 3 at enrollment [adjusted RR (0.95 confidence intervals, CI): 0.8 (0.7, 0.9)] had a 20% lower risk of long TAT or nonreceipt of results when compared with ≥350 cells/mm 3 . Distance between ART center and PCR facility ≥105 km [adjusted RR (0.95 CI): 1.2 (1.1, 1.4)], when compared with mother was high. Point-of-care testing for EID may reduce TAT/nonreceipt of results by the mother. Health system, laboratory, and logistic factors such as sample transportation, laboratory procedures, and result dispatching associated with long TAT should be further explored.

  19. Phase II of a Six sigma Initiative to Study DWPF SME Analytical Turnaround Times: SRNL's Evaluation of Carbonate-Based Dissolution Methods

    International Nuclear Information System (INIS)

    Edwards, Thomas

    2005-01-01

    The Analytical Development Section (ADS) and the Statistical Consulting Section (SCS) of the Savannah River National Laboratory (SRNL) are participating in a Six Sigma initiative to improve the Defense Waste Processing Facility (DWPF) Laboratory. The Six Sigma initiative has focused on reducing the analytical turnaround time of samples from the Slurry Mix Evaporator (SME) by developing streamlined sampling and analytical methods [1]. The objective of Phase I was to evaluate the sub-sampling of a larger sample bottle and the performance of a cesium carbonate (Cs 2 CO 3 ) digestion method. Successful implementation of the Cs 2 CO 3 fusion method in the DWPF would have important time savings and convenience benefits because this single digestion would replace the dual digestion scheme now used. A single digestion scheme would result in more efficient operations in both the DWPF shielded cells and the inductively coupled plasma--atomic emission spectroscopy (ICP-AES) laboratory. By taking a small aliquot of SME slurry from a large sample bottle and dissolving the vitrified SME sample with carbonate fusion methods, an analytical turnaround time reduction from 27 hours to 9 hours could be realized in the DWPF. This analytical scheme has the potential for not only dramatically reducing turnaround times, but also streamlining operations to minimize wear and tear on critical shielded cell components that are prone to fail, including the Hydragard(trademark) sampling valves and manipulators. Favorable results from the Phase I tests [2] led to the recommendation for a Phase II effort as outlined in the DWPF Technical Task Request (TTR) [3]. There were three major tasks outlined in the TTR, and SRNL issued a Task Technical and QA Plan [4] with a corresponding set of three major task activities: (1) Compare weight percent (wt%) total solids measurements of large volume samples versus peanut vial samples. (2) Evaluate Cs 2 CO 3 and K 2 CO 3 fusion methods using DWPF simulated

  20. Pre-K as School Turnaround Strategy

    Science.gov (United States)

    Buenafe, Anthony Q.

    2011-01-01

    Both state and local school systems, recognizing the strong and growing evidence of pre-kindergarten's effectiveness in closing achievement gaps, are implementing early learning programs as part of their education reform efforts. In low-performing districts, pre-k has emerged as a promising turnaround strategy, reaching children before they become…

  1. Identification of Blood Culture Isolates Directly from Positive Blood Cultures by Use of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and a Commercial Extraction System: Analysis of Performance, Cost, and Turnaround Time

    OpenAIRE

    Lagacé-Wiens, Philippe R. S.; Adam, Heather J.; Karlowsky, James A.; Nichol, Kimberly A.; Pang, Paulette F.; Guenther, Jodi; Webb, Amanda A.; Miller, Crystal; Alfa, Michelle J.

    2012-01-01

    Matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsit...

  2. A qualitative investigation on the successful turnaround strategy from top leader perspectives: examples from Indonesia

    Directory of Open Access Journals (Sweden)

    Yulihasri

    2018-06-01

    Full Text Available Turnaround process involved many approaches of strategic and tactical attempts. However, such knowledge are difficult to identified since many previous studies only focused on what constitute successful turnaround, and limited to the use of financial data. As turnaround is a transformational process comprehend every element of organization, ploy on implementing and orchestrating such strategic action should be determined by company’s top leaders. The purpose of this study was to explore the way in which leaders manage the company’s turnaround process and their leadership style through a qualitative study in Indonesian business. Drawing from several top managers in various industry in Indonesia, the result showed that there are many attempt should consider on implementing turnaround process. Financial restructuration, employee’s transformation initiative, and business reengineering process are imperative approaches. Furthermore, leaders need to consider top-down approach on decision making, attention to detail, and open communication to gain employees commitment.

  3. Efficiency of an automated reception and turnaround time management system for the phlebotomy room.

    Science.gov (United States)

    Yun, Soon Gyu; Shin, Jeong Won; Park, Eun Su; Bang, Hae In; Kang, Jung Gu

    2016-01-01

    Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient's information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance. The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system. Mean TAT decreased from 5:45 min to 2:42 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%. The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.

  4. An Integrated Gate Turnaround Management Concept Leveraging Big Data/Analytics for NAS Performance Improvements

    Science.gov (United States)

    Chung, William; Chachad, Girish; Hochstetler, Ronald

    2016-01-01

    The Integrated Gate Turnaround Management (IGTM) concept was developed to improve the gate turnaround performance at the airport by leveraging relevant historical data to support optimization of airport gate operations, which include: taxi to the gate, gate services, push back, taxi to the runway, and takeoff, based on available resources, constraints, and uncertainties. By analyzing events of gate operations, primary performance dependent attributes of these events were identified for the historical data analysis such that performance models can be developed based on uncertainties to support descriptive, predictive, and prescriptive functions. A system architecture was developed to examine system requirements in support of such a concept. An IGTM prototype was developed to demonstrate the concept using a distributed network and collaborative decision tools for stakeholders to meet on time pushback performance under uncertainties.

  5. A generalized linear-quadratic model incorporating reciprocal time pattern of radiation damage repair

    International Nuclear Information System (INIS)

    Huang, Zhibin; Mayr, Nina A.; Lo, Simon S.; Wang, Jian Z.; Jia Guang; Yuh, William T. C.; Johnke, Roberta

    2012-01-01

    Purpose: It has been conventionally assumed that the repair rate for sublethal damage (SLD) remains constant during the entire radiation course. However, increasing evidence from animal studies suggest that this may not the case. Rather, it appears that the repair rate for radiation-induced SLD slows down with increasing time. Such a slowdown in repair would suggest that the exponential repair pattern would not necessarily accurately predict repair process. As a result, the purpose of this study was to investigate a new generalized linear-quadratic (LQ) model incorporating a repair pattern with reciprocal time. The new formulas were tested with published experimental data. Methods: The LQ model has been widely used in radiation therapy, and the parameter G in the surviving fraction represents the repair process of sublethal damage with T r as the repair half-time. When a reciprocal pattern of repair process was adopted, a closed form of G was derived analytically for arbitrary radiation schemes. The published animal data adopted to test the reciprocal formulas. Results: A generalized LQ model to describe the repair process in a reciprocal pattern was obtained. Subsequently, formulas for special cases were derived from this general form. The reciprocal model showed a better fit to the animal data than the exponential model, particularly for the ED50 data (reduced χ 2 min of 2.0 vs 4.3, p = 0.11 vs 0.006), with the following gLQ parameters: α/β = 2.6-4.8 Gy, T r = 3.2-3.9 h for rat feet skin, and α/β = 0.9 Gy, T r = 1.1 h for rat spinal cord. Conclusions: These results of repair process following a reciprocal time suggest that the generalized LQ model incorporating the reciprocal time of sublethal damage repair shows a better fit than the exponential repair model. These formulas can be used to analyze the experimental and clinical data, where a slowing-down repair process appears during the course of radiation therapy.

  6. Research for the energy turnaround. Phase transitions actively shape. Contributions

    International Nuclear Information System (INIS)

    Szczepanski, Petra; Wunschick, Franziska; Martin, Niklas

    2015-01-01

    The Annual Conference 2014 of the Renewable Energy Research Association was held in Berlin on 6 and 7 November 2014. This book documents the contributions of the conference on research for the energy turnaround, phase transitions actively shape. After an introduction and two contributions to the political framework, the contributions to the economic phases of the energy transition, the phase of the current turn, the phases of social energy revolution, the stages of heat turnaround (Waermewende), and the stages of the mobility turn deal with the stages of development of the energy system. Finally, the Research Association Renewable Energy is briefly presented. [de

  7. Turnarounds to Transfer: Design beyond the Modes

    Science.gov (United States)

    Eddy, Jennifer

    2014-01-01

    In "Turnarounds to Transfer," teachers design a collection of tasks toward the summative performance goal but go beyond the Communicative mode criteria: they must assess for transfer. Transfer design criteria must include a complexity or variation that make learners engage critical thinking skills and call upon a repertoire of knowledge…

  8. An Integrated Gate Turnaround Management Concept Leveraging Big Data Analytics for NAS Performance Improvements

    Science.gov (United States)

    Chung, William W.; Ingram, Carla D.; Ahlquist, Douglas Kurt; Chachad, Girish H.

    2016-01-01

    "Gate Turnaround" plays a key role in the National Air Space (NAS) gate-to-gate performance by receiving aircraft when they reach their destination airport, and delivering aircraft into the NAS upon departing from the gate and subsequent takeoff. The time spent at the gate in meeting the planned departure time is influenced by many factors and often with considerable uncertainties. Uncertainties such as weather, early or late arrivals, disembarking and boarding passengers, unloading/reloading cargo, aircraft logistics/maintenance services and ground handling, traffic in ramp and movement areas for taxi-in and taxi-out, and departure queue management for takeoff are likely encountered on the daily basis. The Integrated Gate Turnaround Management (IGTM) concept is leveraging relevant historical data to support optimization of the gate operations, which include arrival, at the gate, departure based on constraints (e.g., available gates at the arrival, ground crew and equipment for the gate turnaround, and over capacity demand upon departure), and collaborative decision-making. The IGTM concept provides effective information services and decision tools to the stakeholders, such as airline dispatchers, gate agents, airport operators, ramp controllers, and air traffic control (ATC) traffic managers and ground controllers to mitigate uncertainties arising from both nominal and off-nominal airport gate operations. IGTM will provide NAS stakeholders customized decision making tools through a User Interface (UI) by leveraging historical data (Big Data), net-enabled Air Traffic Management (ATM) live data, and analytics according to dependencies among NAS parameters for the stakeholders to manage and optimize the NAS performance in the gate turnaround domain. The application will give stakeholders predictable results based on the past and current NAS performance according to selected decision trees through the UI. The predictable results are generated based on analysis of the

  9. Teacher Pay-for-Performance in School Turnaround: How Bonuses and Differentiated Pay Scales Can Help Support School Turnaround. Meeting the Turnaround Challenge: Strategies, Resources & Tools to Transform a Framework into Practice

    Science.gov (United States)

    Mass Insight Education (NJ1), 2009

    2009-01-01

    Given the importance of good teaching and leadership for school success, turnaround schools should think carefully about how to structure professional environments that reward and motivate excellence. A system of "Pay-for-Contribution" that includes tools such as hard-to-staff and skill shortage pay, performance pay, and/or retention…

  10. Decentralized energy policy turnaround. Opportunities and challenges; Dezentrale Energiewende. Chancen und Herausforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Eiselt, Juergen

    2012-07-01

    This book supplies a comprehensive inventory of an already beginning decentralized energy policy turnaround. The potentials of an effective energy policy turnaround are described by means of present structures, technologies and scientifically proven results. The book presents new technologies and effective concepts in order to replace the centralised energy supply by decentralized structures. The reduction of expenses and energy-autonomous systems up to the zero-tariff heating are the main impulses for the utilization of decentralized forms of energy.

  11. Optimal post-warranty maintenance policy with repair time threshold for minimal repair

    International Nuclear Information System (INIS)

    Park, Minjae; Mun Jung, Ki; Park, Dong Ho

    2013-01-01

    In this paper, we consider a renewable minimal repair–replacement warranty policy and propose an optimal maintenance model after the warranty is expired. Such model adopts the repair time threshold during the warranty period and follows with a certain type of system maintenance policy during the post-warranty period. As for the criteria for optimality, we utilize the expected cost rate per unit time during the life cycle of the system, which has been frequently used in many existing maintenance models. Based on the cost structure defined for each failure of the system, we formulate the expected cost rate during the life cycle of the system, assuming that a renewable minimal repair–replacement warranty policy with the repair time threshold is provided to the user during the warranty period. Once the warranty is expired, the maintenance of the system is the user's sole responsibility. The life cycle of the system is defined on the perspective of the user and the expected cost rate per unit time is derived in this context. We obtain the optimal maintenance policy during the maintenance period following the expiration of the warranty period by minimizing such a cost rate. Numerical examples using actual failure data are presented to exemplify the applicability of the methodologies proposed in this paper.

  12. Energy turnaround and expansion of the power grids as seen by the population; Energiewende und Stromnetzausbau aus Sicht der Bevoelkerung

    Energy Technology Data Exchange (ETDEWEB)

    Schumann, Diana; Fischer, Wolfgang; Hake, Juergen-Friedrich [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Energie- und Klimaforschung, Systemforschung und Technologische Entwicklung (IEK-STE)

    2013-07-15

    The expansion of the power grids is a central component of the energy turnaround. However, time and again transmission line construction projects meet with opposition from parts of the population. For the purposes of implementing the energy turnaround it is therefore of interest to ask what factors could be significant for the degree of public acceptance of power transmission lines. Answers to this question are available from the results of a recent representative panel survey on the acceptance in the population of the transformation of the energy supply system.

  13. Citizen investments in the energy policy turnaround; Buergerinvestitionen in die Energiewende

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    The recently recognisable economical and political developments are characterized by an enormous diversity of simultaneously acting processes. These processes challenge the design and balancing attendance of a complex and intense restructuring. Under this aspect, the brochure under consideration presents the following contributions: (1) Energy policy turnaround, investments by citizens and regional development (Peter Jakubowski); (2) Importance of decentralized participation processes for the acceptance of the development of renewable energies. An environmental psychological consideration (Jan Hildebrand); (3) Advantages of cooperative solutions in the energy policy turnaround (Wolfgang George); (4) Significance and potential of energy cooperatives in Germany. An empiric analysis (Richard Volz); (5) Sustainable investment in the energy policy turnaround with the participation of banks and saving banks (Uwe Greff); (6) Financial participation by citizens. Examples of good practice for investment products such as climate savings certificates, subordinated loans or silent participations (Katrin Gehles); (7) The Jurenergie eG: A citizen energy association on a successful course (Vera Ptacek); (8) Regional value creation effects of different organisational forms in respect of the power generation from biomass (Reinhold Kosfeld).

  14. A Software Engineering Paradigm for Quick-turnaround Earth Science Data Projects

    Science.gov (United States)

    Moore, K.

    2016-12-01

    As is generally the case with applied sciences professional and educational programs, the participants of such programs can come from a variety of technical backgrounds. In the NASA DEVELOP National Program, the participants constitute an interdisciplinary set of backgrounds, with varying levels of experience with computer programming. DEVELOP makes use of geographically explicit data sets, and it is necessary to use geographic information systems and geospatial image processing environments. As data sets cover longer time spans and include more complex sets of parameters, automation is becoming an increasingly prevalent feature. Though platforms such as ArcGIS, ERDAS Imagine, and ENVI facilitate the batch-processing of geospatial imagery, these environments are naturally constricting to the user in that they limit him or her to the tools that are available. Users must then turn to "homemade" scripting in more traditional programming languages such as Python, JavaScript, or R, to automate workflows. However, in the context of quick-turnaround projects like those in DEVELOP, the programming learning curve may be prohibitively steep. In this work, we consider how to best design a software development paradigm that addresses two major constants: an arbitrarily experienced programmer and quick-turnaround project timelines.

  15. Biological repair with time-dependent irradiation

    International Nuclear Information System (INIS)

    Broyles, A.A.; Shapiro, C.S.

    1985-01-01

    Recent experiments have provided new data that explore the effectiveness of biological repair in assessing damage due to exposures from ionizing radiation. These data are mainly from experiments conducted at constant dose rates, to study the effectiveness per unit dose of different dose rates. Here, we develop new formulae to estimate the effectiveness of an arbitrary time-dependent dose rate exposure

  16. Improving the turnaround maintenance of the Escravos gas plant / Ishekwene, I.V.

    OpenAIRE

    Ishekwene, Isaac Victor

    2011-01-01

    According to Oliver (2002) the success of turnaround maintenances is measured in terms of the cost of completion, time, safety performance and the performance of the plant afterwards. The Escravos gas plant (EGP) is a gas processing plant that converts associated gas from Chevron owned crude oil wells to liquefied petroleum gas, natural gas and gas condensate (Chevron intranet. Website assessed on September 14, 2007). According to the EGP plant operations coordinator (See inter...

  17. National survey on turnaround time of clinical biochemistry tests in 738 laboratories in China.

    Science.gov (United States)

    Zhang, Xiaoyan; Fei, Yang; Wang, Wei; Zhao, Haijian; Wang, Minqi; Chen, Bingquan; Zhou, Jie; Wang, Zhiguo

    2018-02-01

    This survey was initiated to estimate the current status of turnaround time (TAT) monitoring of clinical biochemistry in China, provide baseline data for establishment of quality specifications and analyze the impact factors of TAT. 738 laboratories were included. Questionnaires involved general information and data of related indicators of TAT during 1 week were provided to participating laboratories. Nine quality indicators were covered, which were medians, 90th and outlier rates of pre-examination, examination, and post-examination TAT. The 25th percentile, median, and 75th percentile of TATs were calculated as optimum, desirable, and minimum quality specifications. Percentages and sigma values were used to describe the outlier rates. Mann-Whitney and Kruskal-Wallis tests were used to identify the potential impacts of TAT. Response rate of this survey was 46.44%. More than 50% of the laboratories indicated they had set up target TATs in three time intervals and monitored TATs generally. The post-examination TAT of most laboratories was 0min, while the pre-examination and examination TAT varied. Sigma values of outlier rates for 45%~60% of laboratories were above 4, while 15%~20% of labs whose sigma values were below 3. Group comparisons suggested nurse or mechanical pipeline transportation, link laboratory information system with hospital information system, and using computer reporting instead of printing report were related to shorter TATs. Despite of the remarkable progresses of TATs in China, there was also room to improve. Laboratories should strengthen the construction of information systems, identify reasons for TAT delay to improve the service quality continuously. © 2017 Wiley Periodicals, Inc.

  18. From turnaround to continuous innovation

    DEFF Research Database (Denmark)

    Bjarnø, Ole-Christian

    2002-01-01

    In this article a five year longitudinal study performed at a medium-sized producer of electronics is reported during which we studied the company's change process. The paper deals with the concept of strategic sourcing as a component in turnaround change management. Based on theories of strategic...... sourcing, explorative case research and continuous innovation a series of findings is identified, and from these findings a management model is proposed. This model is intended to fill in an identified gap in the toolbox for maintenance and further development of the business partners network established...

  19. Peru turnaround tied to privatization

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Petroleos del Peru predicts a 10% increase in Peru's oil production this year and a further increase in 1994. Petroperu also forecasts a sharp increase in drilling in Peru this year. After several years of declining oil production, a gradual turnaround in the cash strapped country's petroleum industry is largely tied to its progress in privatization. The government last year began a campaign to privatize all state owned companies by the end of July 1995. The paper discusses forecasts by Petroperu; the contract of Occidental del Amazonas Inc.; the Petromar privatization; Great Western's contract; development of the Aguaytia gas field; and refinery contracts

  20. Summary inside IBM's historic turnaround

    CERN Document Server

    2014-01-01

    This work offers a summary of the book "WHO SAYS ELEPHANTS CAN'T DANCE? Inside IBM's Historic Turnaround" by Louis Gerstner.In nine years as the chairman and CEO of International Business Machine Corporation (IBM), Louis Gerstner brought about a dramatic change in the company's fortunes. When he took charge, IBM was on the verge of extinction as the victim of rapid changes in the computer industry. However, instead of breaking up IBM as most analysts were suggesting, Gerstner and his management team turned the company around and restored it to a position of power and influence within the indu

  1. Modeling imperfectly repaired system data via grey differential equations with unequal-gapped times

    International Nuclear Information System (INIS)

    Guo Renkuan

    2007-01-01

    In this paper, we argue that grey differential equation models are useful in repairable system modeling. The arguments starts with the review on GM(1,1) model with equal- and unequal-spaced stopping time sequence. In terms of two-stage GM(1,1) filtering, system stopping time can be partitioned into system intrinsic function and repair effect. Furthermore, we propose an approach to use grey differential equation to specify a semi-statistical membership function for system intrinsic function times. Also, we engage an effort to use GM(1,N) model to model system stopping times and the associated operating covariates and propose an unequal-gapped GM(1,N) model for such analysis. Finally, we investigate the GM(1,1)-embed systematic grey equation system modeling of imperfectly repaired system operating data. Practical examples are given in step-by-step manner to illustrate the grey differential equation modeling of repairable system data

  2. Process configuration of Liquid-nitrogen Energy Storage System (LESS) for maximum turnaround efficiency

    Science.gov (United States)

    Dutta, Rohan; Ghosh, Parthasarathi; Chowdhury, Kanchan

    2017-12-01

    Diverse power generation sector requires energy storage due to penetration of variable renewable energy sources and use of CO2 capture plants with fossil fuel based power plants. Cryogenic energy storage being large-scale, decoupled system with capability of producing large power in the range of MWs is one of the options. The drawback of these systems is low turnaround efficiencies due to liquefaction processes being highly energy intensive. In this paper, the scopes of improving the turnaround efficiency of such a plant based on liquid Nitrogen were identified and some of them were addressed. A method using multiple stages of reheat and expansion was proposed for improved turnaround efficiency from 22% to 47% using four such stages in the cycle. The novelty here is the application of reheating in a cryogenic system and utilization of waste heat for that purpose. Based on the study, process conditions for a laboratory-scale setup were determined and presented here.

  3. Mixing Metaphors: Building Infrastructure for Large Scale School Turnaround

    Science.gov (United States)

    Peurach, Donald J.; Neumerski, Christine M.

    2015-01-01

    The purpose of this analysis is to increase understanding of the possibilities and challenges of building educational infrastructure--the basic, foundational structures, systems, and resources--to support large-scale school turnaround. Building educational infrastructure often exceeds the capacity of schools, districts, and state education…

  4. Inducement and responsibility in the energy turnaround

    International Nuclear Information System (INIS)

    Loewer, Wolfgang

    2013-01-01

    The book includes several contributions concerning the Bonn discussion on energy legislation (volume 7): inducement and responsibility -in terms of constitutional law; between Europe and re-regulation - what is the regulation framework? Continuity requirement as legislative action directive; the future of the nuclear fuel tax after the nuclear phaseout - problems of the constitutional finance and the European tax legislation, strategy and energy markets; regulatory challenges in the realization of the energy turnaround policy.

  5. Real-Time Vehicle Routing for Repairing Damaged Infrastructures Due to Natural Disasters

    Directory of Open Access Journals (Sweden)

    Huey-Kuo Chen

    2011-01-01

    Full Text Available We address the task of repairing damaged infrastructures as a series of multidepot vehicle-routing problems with time windows in a time-rolling frame. The network size of the tackled problems changes from time to time, as new disaster nodes will be added to and serviced disaster nodes will be deleted from the current network. In addition, an inaccessible disaster node would become accessible when one of its adjacent disaster nodes has been repaired. By the “take-and-conquer” strategy, the repair sequence of the disaster nodes in the affected area can be suitably scheduled. Thirteen instances were tested with our proposed heuristic, that is, Chen et al.'s approach. For comparison, Hsueh et al.'s approach (2008 with necessary modification was also tested. The results show that Chen et al.'s approach performs slightly better for larger size networks in terms of objective value.

  6. Resolving epidemic network failures through differentiated repair times

    DEFF Research Database (Denmark)

    Fagertun, Anna Manolova; Ruepp, Sarah Renée; Manzano, Marc

    2015-01-01

    In this study, the authors investigate epidemic failure spreading in large-scale transport networks under generalisedmulti-protocol label switching control plane. By evaluating the effect of the epidemic failure spreading on the network,they design several strategies for cost-effective network pe...... assigninglower repair times among the network nodes. They believe that the event-driven simulation model can be highly beneficialfor network providers, since it could be used during the network planning process for facilitating cost-effective networksurvivability design.......In this study, the authors investigate epidemic failure spreading in large-scale transport networks under generalisedmulti-protocol label switching control plane. By evaluating the effect of the epidemic failure spreading on the network,they design several strategies for cost-effective network...... performance improvement via differentiated repair times. First, theyidentify the most vulnerable and the most strategic nodes in the network. Then, via extensive event-driven simulations theyshow that strategic placement of resources for improved failure recovery has better performance than randomly...

  7. Preparing printed circuit boards for rapid turn-around time on a protomat plotter

    International Nuclear Information System (INIS)

    Hawtree, J.

    1998-01-01

    This document describes the use of the LPKF ProtoMat mill/drill unit circuit board Plotter, with the associated CAD/CAM software BoardMaster and CircuitCAM. At present its primarily use here at Fermilab's Particle Physics Department is for rapid-turnover of prototype PCBs double-sided and single-sided copper clad printed circuit boards (PCBs). (The plotter is also capable of producing gravure films and engraving aluminum or plastic although we have not used it for this.) It has the capability of making traces 0.004 inch wide with 0.004 inch spacings which is appropriate for high density surface mount circuits as well as other through-mounted discrete and integrated components. One of the primary benefits of the plotter is the capability to produce double-sided drilled boards from CAD files in a few hours. However to achieve this rapid turn-around time, some care must be taken in preparing the files. This document describes how to optimize the process of PCB fabrication. With proper preparation, researchers can often have a completed circuit board in a day's time instead of a week or two wait with usual procedures. It is assumed that the software and hardware are properly installed and that the machinist is acquainted with the Win95 operating system and the basics of the associated software. This paper does not describe its use with pen plotters, lasers or rubouts. The process of creating a PCB (printed circuit board) begins with the CAD (computer-aided design) software, usually PCAD or VeriBest. These files are then moved to CAM (computer-aided machining) where they are edited and converted to put them into the proper format for running on the ProtoMat plotter. The plotter then performs the actual machining of the board. This document concentrates on the LPKF programs CircuitCam BASIS and BoardMaster for the CAM software. These programs run on a Windows 95 platform to run an LPKF ProtoMat 93s plotter

  8. A deteriorating two-system with two repair modes and sojourn times phase-type distributed

    International Nuclear Information System (INIS)

    Montoro-Cazorla, Delia; Perez-Ocon, Rafael

    2006-01-01

    We study a two-unit cold standby system in steady-state. The online unit goes through a finite number of stages of successive degradation preceding the failure. The units are reparable, there is a repairman and two types of maintenance are considered, preventive and corrective. The preventive repair aims to improve the degradation of a unit being operative. The corrective repair is necessary when the unit fails. We will assume that the preventive repair will be interrupted in favour of a corrective repair in order to increase the availability of the system. The random operational and repair times follow phase-type distributions. For this system, the stationary probability vector, the replacement times, and the involved costs are calculated. An optimisation problem is illustrated by a numerical example. In this, the optimal degradation stage for the preventive repair of the online unit is determined by taking into account the system availability and the incurred costs

  9. A deteriorating two-system with two repair modes and sojourn times phase-type distributed

    Energy Technology Data Exchange (ETDEWEB)

    Montoro-Cazorla, Delia [Departamento de Estadistica e I.O., Escuela Politecnica de Linares, Universidad de Jaen, 23700 Linares, Jaen (Spain); Perez-Ocon, Rafael [Departamento de Estadistica e I.O., Facultad de Ciencias, Universidad de Granada, Granada 18071 (Spain)]. E-mail: rperezo@ugr.es

    2006-01-01

    We study a two-unit cold standby system in steady-state. The online unit goes through a finite number of stages of successive degradation preceding the failure. The units are reparable, there is a repairman and two types of maintenance are considered, preventive and corrective. The preventive repair aims to improve the degradation of a unit being operative. The corrective repair is necessary when the unit fails. We will assume that the preventive repair will be interrupted in favour of a corrective repair in order to increase the availability of the system. The random operational and repair times follow phase-type distributions. For this system, the stationary probability vector, the replacement times, and the involved costs are calculated. An optimisation problem is illustrated by a numerical example. In this, the optimal degradation stage for the preventive repair of the online unit is determined by taking into account the system availability and the incurred costs.

  10. Analytic turnaround time study for integrated reporting of pathology results on electronic medical records using the Illuminate system

    Directory of Open Access Journals (Sweden)

    Tawfik O

    2016-09-01

    Full Text Available Timely pathology results are critical for appropriate diagnosis and management of patients. Yet workflows in laboratories remain ad hoc and involve accessing multiple systems with no direct linkage between patient history and prior or pending pathology records for the case being analyzed. A major hindrance in timely reporting of pathology results is the need to incorporate/interface with multiple electronic health records (EHRs. We evaluated the Illuminate PatientView software (Illuminate integration into pathologist's workflow. Illuminate is a search engine architecture that has a repository of textual information from many hospital systems. Our goal was to develop a comprehensive, user friendly patient summary display to integrate the current fractionated subspecialty specific systems. An analytical time study noting changes in turnaround time (TAT before and after Illuminate implementation was recorded for reviewers, including pathologists, residents and fellows. Reviewers' TAT for 359 cases was recorded (200 cases before and 159 after implementation. The impact of implementing Illuminate on transcriptionists’ workflow was also studied. Average TAT to retrieve EHRs prior to Illuminate was 5:32 min (range 1:35-10:50. That time was significantly reduced to 35 seconds (range 10 sec-1:10 min using Illuminate. Reviewers were very pleased with the ease in accessing information and in eliminating the draft paper documents of the pathology reports, eliminating up to 65 min/day (25-65 min by transcriptionists matching requisition with paperwork. Utilizing Illuminate improved workflow, decreased TAT and minimized cost. Patient care can be improved through a comprehensive patient management system that facilitates communications between isolated information systems.

  11. German energy turnaround and Poland's start in nuclear power? A survey; Deutschlands Energiewende und Polens Einstieg in die Kernenergie? Eine Bestandsaufnahme

    Energy Technology Data Exchange (ETDEWEB)

    Knopp, Lothar; Gorski, Marek (eds.)

    2015-07-01

    The book includes contributions from two meetings: 1. Meeting in Berlin, October 8,2014: Energy transition in Poland - historical background, development and actual situation; legal boundary conditions of the entry into nuclear power in Poland; ecologic and economic causes motivation for the atomic energy entry in Poland; promotion systems for renewable energy in Poland, current status and political background; construction of a nuclear power plant in Northern Poland site specific impacts and social assessment. Meeting in Stettin on November 5, 2014: Energy turnaround in Germany -German nuclear phaseout under consideration of EU legislation; ecologic and economic motivation for the energy turnaround in Germany; energy turnaround in Germany - new legal boundary conditions, especially the amendment to tue renewable energy law; contribution of the industry to the energy turnaround - taking the example waste management and waste incineration plants; fracking as a factor of the energy turnaround? - legal boundary conditions and ecologic risks; ecological, ethical and sociopolitical aspects of the energy turnaround in Germany and Poland.

  12. Transforming Turnaround Schools in China: Strategies, Achievements, and Challenges

    Science.gov (United States)

    Liu, Peng

    2016-01-01

    The existence of turnaround schools has been a problem in the Chinese education system. There are diverse causes including the education system itself, the financial system, and other issues. However, there has been a lack of research to help us fully understand this phenomenon. This article provides a holistic perspective on the strategies the…

  13. Turnaround radius in an accelerated universe with quasi-local mass

    Energy Technology Data Exchange (ETDEWEB)

    Faraoni, Valerio; Lapierre-Léonard, Marianne; Prain, Angus, E-mail: vfaraoni@ubishops.ca, E-mail: mlapierre12@ubishops.ca, E-mail: angusprain@gmail.com [Physics Department, Bishop' s University, 2600 College Street, Sherbrooke, Québec, J1M 1Z7 Canada (Canada)

    2015-10-01

    We apply the Hawking-Hayward quasi-local energy construct to obtain in a rigorous way the turnaround radius of cosmic structures in General Relativity. A splitting of this quasi-local mass into local and cosmological parts describes the interplay between local attraction and cosmological expansion.

  14. Turnaround radius in an accelerated universe with quasi-local mass

    International Nuclear Information System (INIS)

    Faraoni, Valerio; Lapierre-Léonard, Marianne; Prain, Angus

    2015-01-01

    We apply the Hawking-Hayward quasi-local energy construct to obtain in a rigorous way the turnaround radius of cosmic structures in General Relativity. A splitting of this quasi-local mass into local and cosmological parts describes the interplay between local attraction and cosmological expansion

  15. The German 2020 Energy Turnaround Index featuring a special focus on economic efficiency; Energiewende-Index Deutschland 2020. Fokusthema Wirtschaftlichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Vahlenkamp, Thomas [McKinsey and Company, Duesseldorf (Germany); Gohl, Matthias [McKinsey and Company, Berlin (Germany)

    2012-12-15

    The decision to raise the levy imposed by the Renewable Energies Law has kindled the discussion as to how the energy turnaround can best be implemented and made affordable in the first place. The search for solutions should be founded on as full a picture of the situation as possible as well as a fact base shared by all. The aspiration and purpose of the German 2020 Energy Turnaround Index created by McKinsey and Company is to create precisely such a fact base. Every 3 months the index gives an update on the status of the energy turnaround based on 15 indicators. The present update additionally takes a closer look at the aspect of economic efficiency, which together with climate and environment protection and security of supply forms the triad of imperatives driving the energy turnaround.

  16. Rapid-cycle testing cuts bed turnaround by 85%.

    Science.gov (United States)

    2004-11-01

    You can use rapid-cycle testing to try out new approaches to overcrowding much more frequently than with more traditional process improvement strategies. Improving bed turnaround notification can yield dramatic improvements. Telling staff they have to try a new process only for three days makes it easier to gain buy-in. Look for old policies that are no longer needed, yet continue to keep your staff bogged down.

  17. Fast Aircraft Turnaround Enabled by Reliable Passenger Boarding

    Directory of Open Access Journals (Sweden)

    Michael Schultz

    2018-01-01

    Full Text Available Future 4D aircraft trajectories demand comprehensive consideration of environmental, economic, and operational constraints, as well as reliable prediction of all aircraft-related processes. Mutual interdependencies between airports result in system-wide, far-reaching effects in the air traffic network (reactionary delays. To comply with airline/airport challenges over the day of operations, a change to an air-to-air perspective is necessary, with a specific focus on the aircraft ground operations as major driver for airline punctuality. Aircraft ground trajectories primarily consists of handling processes at the stand (deboarding, catering, fueling, cleaning, boarding, unloading, loading, which are defined as the aircraft turnaround. Turnaround processes are mainly controlled by ground handling, airport, or airline staff, except the aircraft boarding, which is driven by passengers’ experience and willingness/ability to follow the proposed boarding procedures. This paper provides an overview of the research done in the field of aircraft boarding and introduces a reliable, calibrated, and stochastic aircraft boarding model. The stochastic boarding model is implemented in a simulation environment to evaluate specific boarding scenarios using different boarding strategies and innovative technologies. Furthermore, the potential of a connected aircraft cabin as sensor network is emphasized, which could provide information on the current and future status of the boarding process.

  18. Policy Perspective: School Turnaround in England. Utilizing the Private Sector

    Science.gov (United States)

    Corbett, Julie

    2014-01-01

    This paper, written by strategic partner of the Center on School Turnaround (CST), Julie Corbett, provides research and examples on England's approach to turning around its lowest performing schools. The English education system utilizes private vendors to support chronically low-performing schools and districts. The introduction is followed by…

  19. CAD/CAM, Creativity, and Discipline Lead to Turnaround School Success

    Science.gov (United States)

    Gorman, Lynn

    2012-01-01

    Miami Central High School technology teacher Frank Houghtaling thinks the connection between theory and application is one reason his students perform better on the Florida Comprehensive Assessment Test (FCAT). The impressive turnaround school drew local and national attention last spring when one of Houghtaling's students, Dagoberto Cruz, won…

  20. Chronically Low-Performing Schools and Turnaround: Evidence from Three States

    Science.gov (United States)

    Hansen, Michael; Choi, Kilchan

    2012-01-01

    The criteria for determining the student outcomes that define a school as having "turned around" are not well defined, and the definition of turnaround performance varies across studies. Although current policy initiatives offer guidelines for identifying CLP schools, there is no standard definition or methodology in common usage. This…

  1. "I've Never Seen People Work So Hard!" Teachers' Working Conditions in the Early Stages of School Turnaround

    Science.gov (United States)

    Cucchiara, Maia Bloomfield; Rooney, Erin; Robertson-Kraft, Claire

    2015-01-01

    School turnaround--a reform strategy that strives for quick and dramatic transformation of low-performing schools--has gained prominence in recent years. This study uses interviews and focus groups conducted with 86 teachers in 13 schools during the early stages of school turnaround in a large urban district to examine teachers' perceptions of the…

  2. Airport Gate Activity Monitoring Tool Suite for Improved Turnaround Prediction, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this research is to create a suite of tools for monitoring airport gate activities with the objective of improving aircraft turnaround. Airport ramp...

  3. Availability and mean life time prediction of multistage degraded system with partial repairs

    International Nuclear Information System (INIS)

    Pham, Hoang; Suprasad, A.; Misra, R.B.

    1997-01-01

    In some environments, components might not always fail fully, but can degrade, and there can be multiple stages of degradation. In such cases, the efficiency of the system may decrease. After a certain stage of degradation the efficiency of the system may decrease to an unacceptable limit and can be considered as a total failure. However, the system can fail randomly from any stage. and can be repaired. Further, the repair action cannot bring the system to the good stage, but can make it operational and the failure rate of the system will, therefore, remain the same as before the failure. In this study, we present a model for predicting the reliability, availability, mean life time, and mean time to first failure of multistage degraded systems with partial repairs. In the analysis, state dependent transition rates for the degradation process, as well as repair processes, are considered. A numerical example is provided to illustrate the results

  4. Anatomy of a public health agency turnaround: the case of the general health district in Mahoning County.

    Science.gov (United States)

    Honoré, Peggy A; Stefanak, Matthew; Dessens, Scott

    2012-01-01

    A turnaround describes an organization's ability to recover from successive periods of decline. Current and projected declines in US economic conditions continue to place local public health departments at risk of fiscal exigency. This examination focused on turnaround methodologies used by a local public health department to reverse successive periods of operational and financial declines. Illustrations are provided on the value added by implementing financial ratio and trend analysis in addition to using evidence-based private sector turnaround strategies of retrenchment, repositioning, and reorganization. Evidence has shown how the financial analysis and strategies aided in identifying operational weakness and set in motion corrective measures. The Public Health Uniform Data System is introduced along with a list of standards offered for mainstreaming these and other routine stewardship practices to diagnose, predict, and prevent agency declines.

  5. Effect of set up time on sublethal repair in multifield fractionated radiotherapy

    International Nuclear Information System (INIS)

    Kehwar, T.S.; Beriwal, Sushil; Sharma, S.C.

    1998-01-01

    The sublethal repair between two doses given with a variable time interval for mammalian cells in tissue culture was first demonstrated successfully by Elkind and Sutton. Subsequently on the basis of concept of sublethal damage repair between fractions, the radio therapists and radio biologists realized that dose can be increased by increasing the small size fractions. This concept is successfully being used in modern radiotherapy

  6. Involvement of DNA polymerase δ in DNA repair synthesis in human fibroblasts at late times after ultraviolet irradiation

    International Nuclear Information System (INIS)

    Dresler, S.L.; Gowans, B.J.; Robinson-Hill, R.M.; Hunting, D.J.

    1988-01-01

    DNA repair synthesis following UV irradiation of confluent human fibroblasts has a biphasic time course with an early phase of rapid nucleotide incorporation and a late phase of much slower nucleotide incorporation. The biphasic nature of this curve suggests that two distinct DNA repair systems may be operative. Previous studies have specifically implicated DNA polymerase δ as the enzyme involved in DNA repair synthesis occurring immediately after UV damage. In this paper, the authors describe studies of DNA polymerase involvement in DNA repair synthesis in confluent human fibroblasts at late times after UV irradiation. Late UV-induced DNA repair synthesis in both intact and permeable cells was found to be inhibited by aphidicolin, indicating the involvement of one of the aphidicolin-sensitive DNA polymerases, α or δ. In permeable cells, the process was further analyzed by using the nucleotide analogue (butylphenyl)-2'-deoxyguanosine 5'-triphosphate, which inhibits DNA polymerase α several hundred times more strongly than it inhibits DNA polymerase δ. The (butylphenyl)-2'-deoxyguanosine 5'-triphosphate inhibition curve for late UV-induced repair synthesis was very similar to that for polymerase δ. It appears that repair synthesis at late time after UV irradiation, like repair synthesis at early times, is mediated by DNA polymerase δ

  7. Role of DNA repair in repair of cytogenetic damages. Slowly repaired DNA injuries involved in cytogenetic damages repair

    International Nuclear Information System (INIS)

    Zaichkina, S.I.; Rozanova, O.M.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    Caffeine was used to study the kinetics of cytogenetic damages repair in Chinese hamster fibroblasts. Its half-time (90 min) was shown to correlate with that of repair of slowly repaired DNA damages. The caffeine-induced increase in the number of irreparable DNA damages, attributed to inhibition of double-strand break repair, is in a quantitative correlation with the effect of the cytogenetic damage modification

  8. Can the universe fragment into many independent causal patches at turnaround in cyclic cosmology?

    International Nuclear Information System (INIS)

    Zhang, Xin

    2009-01-01

    Infinitely cyclic cosmology is often frustrated by the second law of thermodynamics which dictates that the entropy increases from cycle to cycle so that extrapolation into the past will lead back to an initial singularity. It has been argued in the literature that the entropy problem can be resolved in a particular cyclic universe model through a deflation mechanism (i.e., the universe fragments into an astronomically large number of disconnected causal patches at the turnaround). We point out that in this cyclic model the Hubble distance will become infinity at the turnaround; thus the deflation scenario does not seem to be valid. (orig.)

  9. Turnaround, Transformational, or Transactional Leadership: An Ethical Dilemma in School Reform

    Science.gov (United States)

    Mette, Ian M.; Scribner, Jay P.

    2014-01-01

    This case was written for school leaders, specifically building-level principals and central office administrators attempting to implement school turnaround reform efforts. Often, leaders who embark on this type of organizational change work in intense environments that produce high levels of pressure to demonstrate improvement in student…

  10. The Impact of a Health IT Changeover on Medical Imaging Department Work Processes and Turnaround Times: A mixed method study.

    Science.gov (United States)

    Georgiou, A; Prgomet, M; Lymer, S; Hordern, A; Ridley, L; Westbrook, J

    2015-01-01

    To assess the impact of introducing a new Picture Archiving and Communication System (PACS) and Radiology Information System (RIS) on: (i) Medical Imaging work processes; and (ii) turnaround times (TATs) for x-ray and CT scan orders initiated in the Emergency Department (ED). We employed a mixed method study design comprising: (i) semi-structured interviews with Medical Imaging Department staff; and (ii) retrospectively extracted ED data before (March/April 2010) and after (March/April 2011 and 2012) the introduction of a new PACS/RIS. TATs were calculated as: processing TAT (median time from image ordering to examination) and reporting TAT (median time from examination to final report). Reporting TAT for x-rays decreased significantly after introduction of the new PACS/RIS; from a median of 76 hours to 38 hours per order (pMedical Imaging staff reported that the changeover to the new PACS/RIS led to gains in efficiency, particularly regarding the accessibility of images and patient-related information. Nevertheless, assimilation of the new PACS/RIS with existing Departmental work processes was considered inadequate and in some instances unsafe. Issues highlighted related to the synchronization of work tasks (e.g., porter arrangements) and the material set up of the work place (e.g., the number and location of computers). The introduction of new health IT can be a "double-edged sword" providing improved efficiency but at the same time introducing potential hazards affecting the effectiveness of the Medical Imaging Department.

  11. Differences in the Policies, Programs, and Practices (PPPs) and Combination of PPPs across Turnaround, Moderately Improving, and Not Improving Schools

    Science.gov (United States)

    Herman, Rebecca; Huberman, Mette

    2012-01-01

    The TALPS study aims to build on the existing research base to develop promising methodologies to identify chronically low-performing and turnaround schools, as well as to identify promising strategies for turning around chronically low-performing schools. By looking specifically at schools identified as turnaround, in comparison to nonturnaround…

  12. Single-Molecule Methods for Nucleotide Excision Repair: Building a System to Watch Repair in Real Time.

    Science.gov (United States)

    Kong, Muwen; Beckwitt, Emily C; Springall, Luke; Kad, Neil M; Van Houten, Bennett

    2017-01-01

    Single-molecule approaches to solving biophysical problems are powerful tools that allow static and dynamic real-time observations of specific molecular interactions of interest in the absence of ensemble-averaging effects. Here, we provide detailed protocols for building an experimental system that employs atomic force microscopy and a single-molecule DNA tightrope assay based on oblique angle illumination fluorescence microscopy. Together with approaches for engineering site-specific lesions into DNA substrates, these complementary biophysical techniques are well suited for investigating protein-DNA interactions that involve target-specific DNA-binding proteins, such as those engaged in a variety of DNA repair pathways. In this chapter, we demonstrate the utility of the platform by applying these techniques in the studies of proteins participating in nucleotide excision repair. © 2017 Elsevier Inc. All rights reserved.

  13. Robust gap repair in the contractile ring ensures timely completion of cytokinesis.

    Science.gov (United States)

    Silva, Ana M; Osório, Daniel S; Pereira, Antonio J; Maiato, Helder; Pinto, Inês Mendes; Rubinstein, Boris; Gassmann, Reto; Telley, Ivo Andreas; Carvalho, Ana Xavier

    2016-12-19

    Cytokinesis in animal cells requires the constriction of an actomyosin contractile ring, whose architecture and mechanism remain poorly understood. We use laser microsurgery to explore the biophysical properties of constricting rings in Caenorhabditis elegans embryos. Laser cutting causes rings to snap open. However, instead of disintegrating, ring topology recovers and constriction proceeds. In response to severing, a finite gap forms and is repaired by recruitment of new material in an actin polymerization-dependent manner. An open ring is able to constrict, and rings repair from successive cuts. After gap repair, an increase in constriction velocity allows cytokinesis to complete at the same time as controls. Our analysis demonstrates that tension in the ring increases while net cortical tension at the site of ingression decreases throughout constriction and suggests that cytokinesis is accomplished by contractile modules that assemble and contract autonomously, enabling local repair of the actomyosin network. Consequently, cytokinesis is a highly robust process impervious to discontinuities in contractile ring structure. © 2016 Silva et al.

  14. Where the world stands still: turnaround as a strong test of ΛCDM cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Pavlidou, V.; Tomaras, T.N., E-mail: pavlidou@physics.uoc.gr, E-mail: tomaras@physics.uoc.gr [Department of Physics and ITCP, University of Crete, 71003 Heraklion (Greece)

    2014-09-01

    Our intuitive understanding of cosmic structure formation works best in scales small enough so that isolated, bound, relaxed gravitating systems are no longer adjusting their radius; and large enough so that space and matter follow the average expansion of the Universe. Yet one of the most robust predictions of ΛCDM cosmology concerns the scale that separates these limits: the turnaround radius, which is the non-expanding shell furthest away from the center of a bound structure. We show that the maximum possible value of the turnaround radius within the framework of the ΛCDM model is, for a given mass M, equal to (3GM/Λ c{sup 2}){sup 1/3}, with G Newton's constant and c the speed of light, independently of cosmic epoch, exact nature of dark matter, or baryonic effects. We discuss the possible use of this prediction as an observational test for ΛCDM cosmology. Current data appear to favor ΛCDM over alternatives with local inhomogeneities and no Λ. However there exist several local-universe structures that have, within errors, reached their limiting size. With improved determinations of their turnaround radii and the enclosed mass, these objects may challenge the limit and ΛCDM cosmology.

  15. Where the world stands still: turnaround as a strong test of ΛCDM cosmology

    Science.gov (United States)

    Pavlidou, V.; Tomaras, T. N.

    2014-09-01

    Our intuitive understanding of cosmic structure formation works best in scales small enough so that isolated, bound, relaxed gravitating systems are no longer adjusting their radius; and large enough so that space and matter follow the average expansion of the Universe. Yet one of the most robust predictions of ΛCDM cosmology concerns the scale that separates these limits: the turnaround radius, which is the non-expanding shell furthest away from the center of a bound structure. We show that the maximum possible value of the turnaround radius within the framework of the ΛCDM model is, for a given mass M, equal to (3GM/Λ c2)1/3, with G Newton's constant and c the speed of light, independently of cosmic epoch, exact nature of dark matter, or baryonic effects. We discuss the possible use of this prediction as an observational test for ΛCDM cosmology. Current data appear to favor ΛCDM over alternatives with local inhomogeneities and no Λ. However there exist several local-universe structures that have, within errors, reached their limiting size. With improved determinations of their turnaround radii and the enclosed mass, these objects may challenge the limit and ΛCDM cosmology.

  16. IEC ready for turnaround in nuclear industry

    International Nuclear Information System (INIS)

    Schomberg, R.; Corte, E.; Thompson, I.

    2005-01-01

    The activity of IEC Technical Committee (TC) 45 (Nuclear Instrumentation) in conditions of turnaround in nuclear industry is considered. TC 45's main task is to lay down a comprehensive strategy for itself and its two subcommittees as well as to improve the relevance of the nuclear safety standards. Subcommittee 45A develops standards that apply to the electronic and electrical functions and associated systems and equipment used in the instrumentation and control systems of nuclear energy generation facilities. Subcommittee 45B develops and issues standards covering all aspects of instrumentation associated with radiation protection including radiation detectors, radiation monitoring, dosimetry and radiology [ru

  17. Turnaround High School Principals: Recruit, Prepare and Empower Leaders of Change.

    Science.gov (United States)

    Schmidt-Davis, Jon; Bottoms, Gene

    2012-01-01

    Recent studies make one reality clear: While multiple factors can cause a low-performing high school to be in a turnaround situation, every high school that makes dramatic academic improvement has strong, effective school leadership. Turning a school around is no work for novices. It takes a skilled, visionary and proactive principal to pull apart…

  18. The energy turnaround in Switzerland; Die Energiewende der Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Vollrath, Klaus [Redaktionsbuero Klaus Vollrath, Aarwangen (Switzerland)

    2012-12-15

    Not only Germany, Switzerland, too, has opted for an energy turnaround to resolve the question as to its future electricity supply. The decision envisages the decommissioning without replacement of all five existing nuclear power plants. In the debate over possible alternative concepts we are seeing a violent clash between different energy policy positions within the population, the political realm and in the media. If one thing is sure, it is that it will not be cheap.

  19. ECJ judges read the morning papers. Explaining the turnaround of European citizenship jurisprudence

    DEFF Research Database (Denmark)

    Blauberger, Michael; Heindlmaier, Anita; Kramer, Dion

    2018-01-01

    . While the ECJ extended EU citizens’ rights even against strong opposition by member state governments, its recent shift reflects changes in the broader political context, i.e. the politicisation of free movement in the European Union (EU). The article theorizes Court responsiveness to politicisation......Recent jurisprudence of the European Court of Justice (ECJ) marks a striking shift towards a more restrictive interpretation of EU citizens’ rights. The Court’s turnaround is not only highly relevant for practical debates about ‘Social Europe’ or ‘welfare migration’, but also enlightening from...... a more general, theoretical viewpoint. Several recent studies on the ECJ have argued that the Court is largely constrained by member state governments’ threats of legislative override and non-compliance. We show that an additional mechanism is necessary to explain the Court’s turnaround on citizenship...

  20. Models of mixed irradiation with a 'reciprocal-time' pattern of the repair function

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shozo; Miura, Yuri; Mizuno, Shoichi [Tokyo Metropolitan Inst. of Gerontology (Japan); Furusawa, Yoshiya [National Inst. of Radiological Sciences, Chiba (Japan)

    2002-09-01

    Suzuki presented models for mixed irradiation with two and multiple types of radiation by extending the Zaider and Rossi model, which is based on the theory of dual radiation action. In these models, the repair function was simply assumed to be semi-logarithmically linear (i.e., monoexponential), or a first-order process, which has been experimentally contradicted. Fowler, however, suggested that the repair of radiation damage might be largely a second-order process rather than a first-order one, and presented data in support of this hypothesis. In addition, a second-order repair function is preferred to an n-exponential repair function for the reason that only one parameter is used in the former instead of 2n-1 parameters for the latter, although both repair functions show a good fit to the experimental data. However, according to a second-order repair function, the repair rate depends on the dose, which is incompatible with the experimental data. We, therefore, revised the models for mixed irradiation by Zaider and Rossi and by Suzuki, by substituting a 'reciprocal-time' pattern of the repair function, which is derived from the assumption that the repair rate is independent of the dose in a second-order repair function, for a first-order one in reduction and interaction factors of the models, although the underlying mechanism for this assumption cannot be well-explained. The reduction factor, which reduces the contribution of the square of a dose to cell killing in the linear-quadratic model and its derivatives, and the interaction factor, which also reduces the contribution of the interaction of two or more doses of different types of radiation, were formulated by using a 'reciprocal-time' patterns of the repair function. Cell survivals calculated from the older and the newly modified models were compared in terms of the dose-rate by assuming various types of single and mixed irradiation. The result implies that the newly modified models for

  1. Meeting the challenge of a group practice turnaround.

    Science.gov (United States)

    Porn, L M

    2001-03-01

    Many healthcare organizations that acquired group practices to enhance their market share have found that the practices have not met their financial goals. Turning around a financially troubled, hospital-owned group practice is challenging but not impossible for healthcare organizations that take certain basic actions. Direction, data, desire, dedication, and drive must be present to effect the financial turnaround of a group practice. The healthcare organization needs to evaluate the practice's strategy and operations and identify the issues that are hindering the practice's ability to optimize revenues. Efforts to achieve profitable operations have to be ongoing.

  2. Real-Time Multifault Rush Repairing Strategy Based on Utility Theory and Multiagent System in Distribution Networks

    Directory of Open Access Journals (Sweden)

    Zhao Hao

    2016-01-01

    Full Text Available The problem of multifault rush repair in distribution networks (DNs is a multiobjective dynamic combinatorial problem with topology constraints. The problem consists of archiving an optimal faults’ allocation strategy to squads and an admissible multifault rush repairing strategy with coordinating switch operations. In this article, the utility theory is introduced to solve the first problem and a new discrete bacterial colony chemotaxis (DBCC algorithm is proposed for the second problem to determine the optimal sequence for each squad to repair faults and the corresponding switch operations. The above solution is called the two-stage approach. Additionally, a double mathematical optimization model based on the fault level is proposed in the second stage to minimize the outage loss and total repairing time. The real-time adjustment multiagent system (RA-MAS is proposed to provide facility to achieve online multifault rush repairing strategy in DNs when there are emergencies after natural disasters. The two-stage approach is illustrated with an example from a real urban distribution network and the simulation results show the effectiveness of the two-stage approach.

  3. THE EVALUATION OF THE IMPLEMENTATION OF CONTRACTOR SAFETY MANAGEMENT SYSTEM (CSMS PROGRAM ON TURNAROUND PROJECT (TA AT PT. PUPUK SRIWIDJAJA (PUSRI PALEMBANG

    Directory of Open Access Journals (Sweden)

    Muhammad Arif

    2016-03-01

    Full Text Available Background :Turnaround is one of the done by contractor in which if it is not managed well, it could cause work accident. The purpose of this study was to evaluate the implementation of contractor safety management system (CSMS program on turnaround project at PT. Pupuk Sriwidjaja Palembang. Method : This study was a qualitative study. The information was obtained from deep interview, observation and the study of document. The data was analyzed by using content analysis. The validity of the instruments was tested through triangulation of sources, method and data Result : The program implementation Contractor Safety Management System (CSMS on a turnaround project is already well underway only on projects in addition to departments turnaround K3 & LH less involved in the risk assessment stage, pre-qualification and selection of contractors. Conclusion : The implementation of the program Contractor Safety Management System (CSMS on a turnaround project at PT. Pupuk Sriwidjaja Palembang are in accordance with the Code of Labor Management Health, Safety and Environmental Protection Contractor BPMIGAS. It is advisable to PT. Pupuk Sriwidjaja Palembang in order to improve communication between departments procure goods and services with K3 and LH-related departments work tendered as the risk assessment stage, pre-qualification and selection on work tendered. Need sanctions against contractors who do not regularly report performance data K3.

  4. Participatory Democracy and Struggling Schools: Making Space for Youth in School Turnarounds

    Science.gov (United States)

    Kirshner, Ben; Jefferson, Anton

    2015-01-01

    Background/Context:Federal policy, as codified in Race to the Top (RTT) funding guidelines, outlines four types of intervention: turnaround, restart, closure, and transformation. RTT has embraced a technocratic paradigm for school reform that frames choice less as the opportunity for the public to deliberate about what it wants from its schools…

  5. Tinkering and Turnarounds: Understanding the Contemporary Campaign to Improve Low-Performing Schools

    Science.gov (United States)

    Duke, Daniel L.

    2012-01-01

    An unprecedented amount of attention in recent years has been focused on turning around low-performing schools. Drawing on insights from Tyack and Cuban's (1995) "Tinkering Toward Utopia," the article analyzes the forces behind the school turnaround phenomenon and how they have evolved since passage of the No Child Left Behind Act. The…

  6. Decreasing troponin turnaround time in the emergency department using the central laboratory: A process improvement study.

    Science.gov (United States)

    Boelstler, Arlene M; Rowland, Ralph; Theoret, Jennifer; Takla, Robert B; Szpunar, Susan; Patel, Shraddha P; Lowry, Andrew M; Pena, Margarita E

    2015-03-01

    To implement collaborative process improvement measures to reduce emergency department (ED) troponin turnaround time (TAT) to less than 60min using central laboratory. This was an observational, retrospective data study. A multidisciplinary team from the ED and laboratory identified opportunities and developed a new workflow model. Process changes were implemented in ED patient triage, staffing, lab collection and processing. Data collected included TAT of door-to-order, order-to-collect, collect-to-received, received-to-result, door-to-result, ED length of stay, and hemolysis rate before (January-August, 2011) and after (September 2011-June 2013) process improvement. After process improvement and implementation of the new workflow model, decreased median TAT (in min) was seen in door-to-order (54 [IQR43] vs. 11 [IQR20]), order-to-collect (15 [IQR 23] vs. 10 [IQR12]), collect-to-received (6 [IQR8] vs. 5 [IQR5]), received-to-result (30 [IQR12] vs. 24 [IQR11]), and overall door-to-result (117 [IQR60] vs. 60 [IQR40]). A troponin TAT of <60min was realized beginning in May 2012 (59 [IQR39]). Hemolysis rates decreased (14.63±0.74 vs. 3.36±1.99, p<0.0001), as did ED length of stay (5.87±2.73h vs. 5.15±2.34h, p<0.0001). Conclusion Troponin TAT of <60min using a central laboratory was achieved with collaboration between the ED and the laboratory; additional findings include a decreased ED length of stay. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. A geometric process repair model for a repairable cold standby system with priority in use and repair

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Wang Guanjun

    2009-01-01

    In this paper, a deteriorating cold standby repairable system consisting of two dissimilar components and one repairman is studied. For each component, assume that the successive working times form a decreasing geometric process while the consecutive repair times constitute an increasing geometric process, and component 1 has priority in use and repair. Under these assumptions, we consider a replacement policy N based on the number of repairs of component 1 under which the system is replaced when the number of repairs of component 1 reaches N. Our problem is to determine an optimal policy N* such that the average cost rate (i.e. the long-run average cost per unit time) of the system is minimized. The explicit equation of the average cost rate of the system is derived and the corresponding optimal replacement policy N* can be determined analytically or numerically. Finally, a numerical example with Weibull distribution is given to illustrate some theoretical results in this paper.

  8. A recursive framework for time-dependent characteristics of tested and maintained standby units with arbitrary distributions for failures and repairs

    International Nuclear Information System (INIS)

    Vaurio, Jussi K.

    2015-01-01

    The time-dependent unavailability and the failure and repair intensities of periodically tested aging standby system components are solved with recursive equations under three categories of testing and repair policies. In these policies, tests or repairs or both can be minimal or perfect renewals. Arbitrary distributions are allowed to times to failure as well as to repair and renewal durations. Major preventive maintenance is done periodically or at random times, e.g. when a true demand occurs. In the third option process renewal is done if a true demand occurs or when a certain mission time has expired since the previous maintenance, whichever occurs first. A practical feature is that even if a repair can renew the unit, it does not generally renew the alternating process. The formalism updates and extends earlier results by using a special backward-renewal equation method, by allowing scheduled tests not limited to equal intervals and accepting arbitrary distributions and multiple failure types and causes, including failures caused by tests, human errors and true demands. Explicit solutions are produced to integral equations associated with an age-renewal maintenance policy. - Highlights: • Time-dependent unavailability, failure count and repair count for a standby system. • Free testing schedule and distributions for times to failure, repair and maintenance. • Multiple failure modes; tests or repairs or both can be minimal or perfect renewals. • Process renewals periodically, randomly or based on the process age or an initiator. • Backward renewal equations as explicit solutions to Volterra-type integral equations

  9. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  10. A Case Study of Change Strategies Implemented in a Turnaround Elementary School

    Science.gov (United States)

    Colson, Jo Ann

    2012-01-01

    This case study examined the change strategies in a turnaround school at the elementary level to understand and describe how change occurred and was sustained at this campus. This study examined the factors which contributed to the change in academic success of students, examined beliefs about change that led to the change process, identified the…

  11. Reward optimization of a repairable system

    International Nuclear Information System (INIS)

    Castro, I.T.; Perez-Ocon, R.

    2006-01-01

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures

  12. Reward optimization of a repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Castro, I.T. [Departamento de Matematicas, Facultad de Veterinaria, Universidad de Extremadura, Avenida de la Universidad, s/n. 10071 Caceres (Spain)]. E-mail: inmatorres@unex.es; Perez-Ocon, R. [Departamento de Estadistica e Investigacion Operativa, Facultad de Ciencias, Universidad de Granada, Avenida de Severo Ochoa, s/n. 18071 Granada (Spain)]. E-mail: rperezo@ugr.es

    2006-03-15

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures.

  13. Into the black. 1993 Hospital Turnaround Contest winners.

    Science.gov (United States)

    Cerne, F; Bergman, R

    1993-07-20

    Turning a hospital around takes a lot more than adjusting the financials, as the winners and finalists in the Great Comebacks 1993: The Hospital Turnaround Contest demonstrate. In every case we report on, the hospital being recognized has worked intensively with its community to reassess the services needed by its patients, build support for major management and delivery changes, and articulate the reasons for the strategies being used. Each of the eight hospital organizations we profile, which are spread across the country from Texas to Wisconsin to Maine to North Carolina--has put together its own version of success--in other words, eight lessons in innovation and progress.

  14. The impact of mean time to repair modifications

    International Nuclear Information System (INIS)

    Nitoi, M.; Apostol, M.; Florescu, G.; Farcasiu, M.

    2004-01-01

    The assessment of the nuclear power plant safety is one of the safety principles; its application intends to lead to the improvement of safety in all the states that have nuclear power plants. The sensitivity analyses are an integral part of the probabilistic safety evaluation of the Cernavoda nuclear plant safety (CPSE - Cernavoda Probabilistic Safety Evaluation Study). An impact study of the changes in model and assumptions on final result gives a better perspective on study conclusions. The paper presents the impact on plant systems unavailability of the changes in components mean time to repair. (author)

  15. Investigating the Role of Human Resources in School Turnaround: Evidence from Two States

    Science.gov (United States)

    Hansen, Michael

    2012-01-01

    Teachers are generally recognized as the schooling factor accounting for the highest proportion of student learning outcomes (Aaronson et al., 2007; Hanushek, 1986). This implies the quick and dramatic improvement in school performance observed in turnaround (TA) schools was associated with a major change in the performance of its teachers. This…

  16. Control of a maintenance system when failure and repair times have phase type distributions

    Science.gov (United States)

    Decassiamenesesrodrigues, Rita

    1990-09-01

    In the model of machine repair discussed there are M + R identical machines, M operating, and R spares. All machines are independent of one another. When an operating machine fails, it is sent to a single server repair station and immediately replaced by a spare machine, if one is available. The server has two available service types to choose from. There are waiting costs, repair costs, lost production costs, and switch-over costs. The following decision problem is treated: to obtain a stationary policy which determines the service type as a function of the state of the system in order to minimize the long-run average cost when failure and repair times have second-order Coxian distribution. This control problem is represented by a semi-Markov decision process. The policy-iteration algorithm and the value-iteration algorithm are used to obtain the optimal policy. Numerical results are given for these two optimization methods.

  17. Usage of OpenStack Virtual Machine and MATLAB HPC Add-on leads to faster turnaround

    KAUST Repository

    Van Waveren, Matthijs

    2017-03-16

    We need to run hundreds of MATLAB® simulations while changing the parameters between each simulation. These simulations need to be run sequentially, and the parameters are defined manually from one simulation to the next. This makes this type of workload unsuitable for a shared cluster. For this reason we are using a cluster running in an OpenStack® Virtual Machine and are using the MATLAB HPC Add-on for submitting jobs to the cluster. As a result we are now able to have a turnaround time for the simulations of the order of a few hours, instead of the 24 hours needed on a local workstation.

  18. ROCLA robots repaired after tough times

    CERN Multimedia

    Patrice Loïezi

    2004-01-01

    The team of five welders and five mechanics, represented by Pascal Mésenge (right) and Fabrice Multon (left), worked during two week-ends to repair the two ROCLA. At the centre, Oliver Boettcher, technical manager for the robot.

  19. Real-time fluorescence imaging of the DNA damage repair response during mitosis.

    Science.gov (United States)

    Miwa, Shinji; Yano, Shuya; Yamamoto, Mako; Matsumoto, Yasunori; Uehara, Fuminari; Hiroshima, Yukihiko; Toneri, Makoto; Murakami, Takashi; Kimura, Hiroaki; Hayashi, Katsuhiro; Yamamoto, Norio; Efimova, Elena V; Tsuchiya, Hiroyuki; Hoffman, Robert M

    2015-04-01

    The response to DNA damage during mitosis was visualized using real-time fluorescence imaging of focus formation by the DNA-damage repair (DDR) response protein 53BP1 linked to green fluorescent protein (GFP) (53BP1-GFP) in the MiaPaCa-2(Tet-On) pancreatic cancer cell line. To observe 53BP1-GFP foci during mitosis, MiaPaCa-2(Tet-On) 53BP1-GFP cells were imaged every 30 min by confocal microscopy. Time-lapse imaging demonstrated that 11.4 ± 2.1% of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells had increased focus formation over time. Non-mitotic cells did not have an increase in 53BP1-GFP focus formation over time. Some of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells with focus formation became apoptotic. The results of the present report suggest that DNA strand breaks occur during mitosis and undergo repair, which may cause some of the mitotic cells to enter apoptosis in a phenomenon possibly related to mitotic catastrophe. © 2014 Wiley Periodicals, Inc.

  20. Successful integration of fast track projects into turnarounds

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J. Patrick; Loureiro, Ramon C. [KBC Advanced Technologies, Surrey (United Kingdom)

    2012-07-01

    Fast track projects can provide quick wins and competitive advantage. However, in most cases the implementation of these projects requires a shutdown for installing the necessary tie-ins or integration into an upcoming turnaround (TA). Depending on the nature of the project and complexity of the TA, the integration can be seamless or result in cost or duration overruns and safety incidents. The risk of such overruns and safety incidents increases with the amount of project work to be integrated into the operations, maintenance and inspection schedules to be executed during the TA. The risk further increases with TA size and other factors. If not planned and scheduled properly and in a timely fashion, capital projects, in particular fast track projects trying to take advantage of an upcoming TA, can severely impact both TA performance, and the safety and reliability of the facility until the next opportunity for eliminating the defects introduced during the TA. Successful TAs are those delivered in a safe, on time, on budget manner, and with the quality standards needed for a leak-free start-up and a safe and reliable operation over the next run cycle. This paper discusses the key elements that are required to minimize the TA risks derived from the inclusion of fast track projects and how to establish the cut off criteria to either cancel or defer the project, or delay the TA in order to balance TA scope freeze and the case for compelling economics.(author)

  1. A Novel Analytic Technique for the Service Station Reliability in a Discrete-Time Repairable Queue

    Directory of Open Access Journals (Sweden)

    Renbin Liu

    2013-01-01

    Full Text Available This paper presents a decomposition technique for the service station reliability in a discrete-time repairable GeomX/G/1 queueing system, in which the server takes exhaustive service and multiple adaptive delayed vacation discipline. Using such a novel analytic technique, some important reliability indices and reliability relation equations of the service station are derived. Furthermore, the structures of the service station indices are also found. Finally, special cases and numerical examples validate the derived results and show that our analytic technique is applicable to reliability analysis of some complex discrete-time repairable bulk arrival queueing systems.

  2. Time-lapse crystallography snapshots of a double-strand break repair polymerase in action.

    Science.gov (United States)

    Jamsen, Joonas A; Beard, William A; Pedersen, Lars C; Shock, David D; Moon, Andrea F; Krahn, Juno M; Bebenek, Katarzyna; Kunkel, Thomas A; Wilson, Samuel H

    2017-08-15

    DNA polymerase (pol) μ is a DNA-dependent polymerase that incorporates nucleotides during gap-filling synthesis in the non-homologous end-joining pathway of double-strand break repair. Here we report time-lapse X-ray crystallography snapshots of catalytic events during gap-filling DNA synthesis by pol μ. Unique catalytic intermediates and active site conformational changes that underlie catalysis are uncovered, and a transient third (product) metal ion is observed in the product state. The product manganese coordinates phosphate oxygens of the inserted nucleotide and PP i . The product metal is not observed during DNA synthesis in the presence of magnesium. Kinetic analyses indicate that manganese increases the rate constant for deoxynucleoside 5'-triphosphate insertion compared to magnesium. The likely product stabilization role of the manganese product metal in pol μ is discussed. These observations provide insight on structural attributes of this X-family double-strand break repair polymerase that impact its biological function in genome maintenance.DNA polymerase (pol) μ functions in DNA double-strand break repair. Here the authors use time-lapse X-ray crystallography to capture the states of pol µ during the conversion from pre-catalytic to product complex and observe a third transiently bound metal ion in the product state.

  3. Turnaround in an aged persons' mental health service in crisis: a case study of organisational renewal.

    Science.gov (United States)

    Stafrace, Simon; Lilly, Alan

    2008-08-01

    This case study demonstrates how leadership was harnessed to turn around a decline in the performance of an aged persons' mental health service - the Namarra Nursing Home at Caulfield General Medical Centre in Melbourne, Australia. In 2000 the nursing home faced a crisis of public confidence due to failings in the management of quality, clinical risk and human resources within the service. These problems reflected structural and operational shortcomings in the clinical directorate and wider organisation. In this article, we detail the process of turnaround from the perspective of senior executive managers with professional and operational responsibility for the service. This turnaround required attention to local clinical accountability and transformation of the mental health program from a collocated but operationally isolated service to one integrated within the governance structures of the auspicing organisation.

  4. The First 90 Days of the New Middle School Principal in a Turnaround School: In-Depth Case Study of the Transition Period (First 90 Days)

    Science.gov (United States)

    Baeza, Marco A.

    2010-01-01

    This study analyzed skills, strategies, and theories that new middle school principals used to be successful during their transition period (the first 90 days) in turnaround schools. Based on research on transitions, three research questions guided the study: 1. Do middle school principals in a turnaround school situation find the transition…

  5. How to Know when Dramatic Change Is on Track: Leading Indicators of School Turnarounds

    Science.gov (United States)

    Kowal, Julie; Ableidinger, Joe

    2011-01-01

    In recent years, national policymakers have placed new emphasis on "school turnarounds" as a strategy for rapid, dramatic improvement in chronically failing schools, calling on education leaders to turn around performance in the 5,000 lowest-achieving schools nationwide. This goal may seem daunting, given the dismal success rates of…

  6. MX/G1, G2/1 with Setup Time, Bernoulli Vacation, Break Down, and Delayed Repair

    Directory of Open Access Journals (Sweden)

    G. Ayyappan

    2014-01-01

    Full Text Available We present a single server in which customers arrive in batches and the server provides service one by one. The server provides two heterogeneous service stages such that service time of both stages is different and mandatory to all arriving customers in such a way that, after the completion of first stage, the second stage should also be provided to the customers. The server may subject to random breakdowns with brake down rate λ and, after break down, it should be repaired but it has to wait for being repaired and such waiting time is called delay time. Both the delay time and repair time follow exponential distribution. Upon the completion of the second stage service, the server will go for vacation with probability p or stay back in the system probability 1-p, if any. The vacation time follows general (arbitrary distribution. Before providing service to a new customer or a batch of customers that joins the system in the renewed busy period, the server enters into a random setup time process such that setup time follows exponential distribution. We discuss the transient behavior and the corresponding steady state results with the performance measures of the model.

  7. Is "Turnaround" a useful model for low-performing schools?

    Directory of Open Access Journals (Sweden)

    Sandra Stotsky

    2015-04-01

    Full Text Available Since passage of the No Child Left Behind act in 2001, all states have been under federal pressure to identify “failing schools.” The US Department of Education has strongly encouraged “turnaround” as an option for schools to use in order to improve student achievement. The study reported here reviewed the research literature on school “turnaround,” with a particular focus on the results in Arkansas of the use of the same “turnaround” partner (America’s Choice for over five years for many of the state’s “failing” elementary, middle, and high schools. There was little evidence to support either this partner or this policy option. The lack of evidence raises a basic question about the usefulness and cost of the federal government’s intervention in local education policy. Nor is it clear how a new program titled Excellence for All now offered by the developers of America’s Choice will differ. It is described as follows: “Excellence for All provides a clear, practical strategy for every student to graduate from high school prepared to succeed in college or in a program of career and technical education that will lead to a successful career.” We are also told: “Excellence for All is aligned with the Common Core State Standards, enabling participating high schools to not just lay the foundation for the Common Core but to get a head start on implementation.” According to a draft of a yet-to-be-voted-on re-authorization of the Elementary and Secondary Education Act (ESEA/NCLB, state departments of education are to submit “college-ready” standards for approval by the USDE if they want Title I funds. However, state legislators, local school board members, parents, and a state’s own higher education academic experts are excluded from approving the standards their state department of education submits, perhaps to ensure that only the “right” standards are submitted. If the language in the current re

  8. Welded repair joints of boiler steels following operation in creep conditions exceeding the design time of operation

    Energy Technology Data Exchange (ETDEWEB)

    Dobrzanski, J.; Paszkowska, H.; Zielinski, A. [Institute for Ferrous Metallurgy, Gliwice (Poland)

    2010-07-01

    The assessment of suitability for further operation for materials and welded repair joints of thick-walled main steam pipeline components, made of steel 14MoV63, as well as steam superheater outlet headers made of steel X20CrMoV121 following operation in creep conditions in time periods considerably longer than the specified calculated time of operation. Strength properties, impact strength and transition temperature into brittle condition, as well as structure condition have been evaluated. On the basis of shortened creep tests, the residual life and disposable residual life of materials and welded joints have been determined. Material properties following operation and those of fabricated circumferential welded repair joints have been compared. The condition of examined components and suitability of the fabricated welded repair joints for further operation have been assessed. (orig.)

  9. ROCLA robots repaired after tough times

    CERN Multimedia

    2004-01-01

    The team of five welders and five mechanics, represented by Pascal Mésenge (right) and Fabrice Multon (left), worked during two week-ends to repair the two ROCLA. At the centre, Oliver Boettcher, technical manager for the robot. The two LHC magnet transport robots ROCLA have recently been repaired after cracks were found in the welds of their load-bearing structure. The Safety Commission suspended the use of one robot and limited the operation conditions of the other. These vehicles are used intensively for the transport of the LHC cryodipoles between the test and the assembly facilities SM18 and SMA18. As a consequence, a speedy solution had to be implemented to minimize the potential disruption to the LHC schedule. Appropriate CERN resources were immediately focused on the problem. As soon as TS/MME had designed a reinforced gantry support, the necessary raw material was ordered. Less than 10 days were required to get the two ROCLA robots operating again. This included 2 full weekends, many extra hours a...

  10. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  11. Mastering the complexity of the energy turnaround. Outcome of the Energy Competence Initiative; Die Komplexitaet der Energiewende bewaeltigen. Ergebnisse der Kompetenzinitiative Energie

    Energy Technology Data Exchange (ETDEWEB)

    Rolle, Carsten; Niessen, Philipp [BDI, Berlin (Germany). Abt. Energie- und Klimapolitik

    2013-06-15

    The energy turnaround is one of the central economic and political projects of the German federal government and goes far beyond a mere replacement of Germany's power plant fleet. This insight has only slowly emerged in the course of the past months. It led the German industry last year to systemically analyse the multifarious effects of the energy turnaround within the framework of the Energy Competence Initiative. Different implications were considered, reaching beyond the sphere of the energy economy itself, and making use of the sector-specific expertise of all associations organised within the Federation of German Industry (BDI) as well as the support of scientists and consultants. The goal was to take stock of the wider effects of the energy turnaround on the German industry and on Germany as an industrial site. In the spring of 2013 the results of two empirical studies on the topic became available. This article contains selected results from these two studies.

  12. The Effects of School Turnaround in Tennessee's Achievement School District and Innovation Zones

    Science.gov (United States)

    Zimmer, Ron; Henry, Gary T.; Kho, Adam

    2017-01-01

    In recent years, the federal government has invested billions of dollars to reform chronically low-performing schools. To fulfill their federal Race to the Top grant agreement, Tennessee implemented three turnaround strategies that adhered to the federal restart and transformation models: (a) placed schools under the auspices of the Achievement…

  13. Energy turnaround in the traffic sector. What contribution can be achieved with biofuels?; Energiewende im Verkehrssektor. Welcher Beitrag ist durch Biokraftstoffe erreichbar?

    Energy Technology Data Exchange (ETDEWEB)

    Adolf, Joerg [Shell Deutschland, Hamburg (Germany); Fritsche, Uwe [Internationales Institut fuer Nachhaltigkeitsanalysen und -strategien, Darmstadt (Germany)

    2013-03-15

    The energy turnaround is only making slow progress in the traffic sector. Biofuels, the most important alternative energy resource for traffic applications, have come under criticism, and their growth has stalled in recent years. Two questions present themselves in this situation: Where do biofuels stand today? And what can they contribute in future to the energy turnaround in the traffic sector? The present study on challenges and potentials associated with the use of biofuels in the traffic sector investigates the direction of current developments.

  14. Energy in a dialog. The challenges facing Germany's power industry as a result of the energy turnaround

    International Nuclear Information System (INIS)

    Gueldner, Ralf

    2012-01-01

    The challenges posed by the energy turnaround in Germany to the power industry and the national economy after the Fukushima events were the topic of the ''Energy in a Dialog'' meeting organized by the Deutsches Atomforum in Berlin on December 14, 2011. Dr. Ralf Gueldner, President of the Deutsches Atomforum, opened the conference by drawing attention to the real purposes of the energy turnaround, namely to prevent severe climate changes and, thus, also carbon emissions. Both nationally in Germany and worldwide, nuclear power made major contributions to achieving these goals. Referring to developments in many neighboring countries, he underlined that opting out of the use of nuclear power in Germany was not tantamount to the end of nuclear power. Reality in energy policy had to be accepted, however, namely that nuclear power played, and would go on playing, an important role in Europe. Other contributions by Dr. Juergen Grossmann (Chief Executive Officer of RWE AG), Stefan Kohler (Chairman of the Board of Management of the German Energy Agency - dena), and Prof.Dr. Felix Muesgens (Brandenburg Technical University of Cottbus, Chair of Power Economics) dealt with political and other boundary conditions required for the energy turnaround, and with the consequences and burdens on the power industry and the national economy. A final panel discussion chaired by Henning Krumrey (Wirtschaftswoche) was attended by F. Muesgens and Prof. Dr. Hans-Werner Sinn (President of the Munich-based Info Institute) and Prof. Dr. Michael Huether (German Business Institute). (orig.)

  15. Inducement and responsibility in the energy turnaround; Veranlassung und Verantwortung bei der Energiewende

    Energy Technology Data Exchange (ETDEWEB)

    Loewer, Wolfgang (ed.)

    2013-07-01

    The book includes several contributions concerning the Bonn discussion on energy legislation (volume 7): inducement and responsibility -in terms of constitutional law; between Europe and re-regulation - what is the regulation framework? Continuity requirement as legislative action directive; the future of the nuclear fuel tax after the nuclear phaseout - problems of the constitutional finance and the European tax legislation, strategy and energy markets; regulatory challenges in the realization of the energy turnaround policy.

  16. Shuttle Repair Tools Automate Vehicle Maintenance

    Science.gov (United States)

    2013-01-01

    Successfully building, flying, and maintaining the space shuttles was an immensely complex job that required a high level of detailed, precise engineering. After each shuttle landed, it entered a maintenance, repair, and overhaul (MRO) phase. Each system was thoroughly checked and tested, and worn or damaged parts replaced, before the shuttle was rolled out for its next mission. During the MRO period, workers needed to record exactly what needed replacing and why, as well as follow precise guidelines and procedures in making their repairs. That meant traceability, and with it lots of paperwork. In 2007, the number of reports generated during electrical system repairs was getting out of hand-placing among the top three systems in terms of paperwork volume. Repair specialists at Kennedy Space Center were unhappy spending so much time at a desk and so little time actually working on the shuttle. "Engineers weren't spending their time doing technical work," says Joseph Schuh, an electrical engineer at Kennedy. "Instead, they were busy with repetitive, time-consuming processes that, while important in their own right, provided a low return on time invested." The strain of such inefficiency was bad enough that slow electrical repairs jeopardized rollout on several occasions. Knowing there had to be a way to streamline operations, Kennedy asked Martin Belson, a project manager with 30 years experience as an aerospace contractor, to co-lead a team in developing software that would reduce the effort required to document shuttle repairs. The result was System Maintenance Automated Repair Tasks (SMART) software. SMART is a tool for aggregating and applying information on every aspect of repairs, from procedures and instructions to a vehicle s troubleshooting history. Drawing on that data, SMART largely automates the processes of generating repair instructions and post-repair paperwork. In the case of the space shuttle, this meant that SMART had 30 years worth of operations

  17. Stochastic Modelling Of The Repairable System

    Directory of Open Access Journals (Sweden)

    Andrzejczak Karol

    2015-11-01

    Full Text Available All reliability models consisting of random time factors form stochastic processes. In this paper we recall the definitions of the most common point processes which are used for modelling of repairable systems. Particularly this paper presents stochastic processes as examples of reliability systems for the support of the maintenance related decisions. We consider the simplest one-unit system with a negligible repair or replacement time, i.e., the unit is operating and is repaired or replaced at failure, where the time required for repair and replacement is negligible. When the repair or replacement is completed, the unit becomes as good as new and resumes operation. The stochastic modelling of recoverable systems constitutes an excellent method of supporting maintenance related decision-making processes and enables their more rational use.

  18. End of the nuclear energy era? From Fukushima to the energy policy turnaround; Ende des Atomzeitalters? Von Fukushima in die Energiewende

    Energy Technology Data Exchange (ETDEWEB)

    Piepenbrink, Johannes (comp.)

    2012-07-01

    Due to a violent earthquake and the resulting tsunami, a core melt down resulted at the nuclear power plant Fukushima Daiichi in Japan. Thus, at 30th June, 2011, the Federal Government decided to complete the utilization of the nuclear power in Germany. Is this the end of the atomic age? Under this aspect, the booklet under consideration consists of the following nine contributions: (1) Why is the ''energy policy turnaround'' a social question? (Harald Welzer); (2) Tsunami in the living room: Catastrophes facilitated by the media (Joerg R. Bergmann); (3) Learning from the catastrophe (Manfred Buerger); (4) Perspectives of the nuclear power in Europe and globally (Lutz Mez); (5) Outsider or leader? The 'model Germany' and the European energy policy (Severin Fischer); (6) 'Energy policy turnaround': Quo vadis? (Hardo Bruhns); (7) Energy policy turnarounds in Germany: Motifs and impacts for the European electricity market (Hans-Jochen Luhmann); (8) A short story of the German anti-nuclear movement (Joachim Radkau); (9) Popularity of the apocalypse: Reflections on the cultural history of the fear against nuclear accidents since 1945 (Philipp Gassert).

  19. The Reading Turn-Around: A Five Part Framework for Differentiated Instruction. Practitioners Bookshelf, Language & Literacy Series

    Science.gov (United States)

    Jones, Stephanie; Clarke, Lane; Enriquez, Grace

    2009-01-01

    This book demonstrates a five-part framework for teachers, reading specialists, and literacy coaches who want to help their least engaged students become powerful readers. Merging theory and practice, the guide offers successful strategies to reach your "struggling" learners. The authors show how you can "turn-around" your instructional practice,…

  20. A real-time expert system for self-repairing flight control

    Science.gov (United States)

    Gaither, S. A.; Agarwal, A. K.; Shah, S. C.; Duke, E. L.

    1989-01-01

    An integrated environment for specifying, prototyping, and implementing a self-repairing flight-control (SRFC) strategy is described. At an interactive workstation, the user can select paradigms such as rule-based expert systems, state-transition diagrams, and signal-flow graphs and hierarchically nest them, assign timing and priority attributes, establish blackboard-type communication, and specify concurrent execution on single or multiple processors. High-fidelity nonlinear simulations of aircraft and SRFC systems can be performed off-line, with the possibility of changing SRFC rules, inference strategies, and other heuristics to correct for control deficiencies. Finally, the off-line-generated SRFC can be transformed into highly optimized application-specific real-time C-language code. An application of this environment to the design of aircraft fault detection, isolation, and accommodation algorithms is presented in detail.

  1. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  2. Measuring trade-offs that matter: assessing the impact of a new electronic cross-match policy on the turnaround time and the cross-match workload efficiency.

    Science.gov (United States)

    Lin, David M; Goldfinger, Dennis; Lu, Qun; Wallace, Bridget; Kosaka-Nguyen, Dawn; Wood, Alisa; Porter, Bethany; Bumerts, Pamela; Jeffery, Rebecca; Fang, Amy; Stalcup, Irene; Penaflorida, Tracy; Ziman, Alyssa

    2014-12-01

    Our traditional cross-match (XM) policy generated a significant number of XM units that were never issued. To minimize the unnecessary XM workload, we proposed a new policy where orders eligible for the electronic XM (EXM) are pended until orders to issue red blood cells (RBCs) are received. To address concerns that this new policy might unduly delay blood availability, we conducted a study to assess whether the new policy was noninferior to the traditional policy with regard to the turnaround time (TAT). We monitored the TAT and XM workload efficiency (XM-to-issue [C : I] ratio) for a total of 8 weeks split between the two policies' periods. The primary outcome was the proportion of RBC issue requests that was turned around in less than 12 minutes. Fifty percent (1133 of 2265) of issue requests were turned around in 12 minutes or less under the traditional policy compared to 43.9% (975 of 2223) under the new policy (absolute difference of 6.1%; 95% confidence interval [CI], 3.2%-9.1%; p trade-off between delays in the TAT and efficiency gains in the XM workload remained acceptable for patient care. © 2014 AABB.

  3. Portfolio District Reform Meets School Turnaround: Early Implementation Findings from the Los Angeles Public School Choice Initiative

    Science.gov (United States)

    Marsh, Julie A.; Strunk, Katharine O.; Bush, Susan

    2013-01-01

    Purpose: Despite the popularity of school "turnaround" and "portfolio district" management as solutions to low performance, there has been limited research on these strategies. The purpose of this paper is to address this gap by exploring the strategic case of Los Angeles Unified School District's Public School Choice…

  4. The Double Bind for Women: Exploring the Gendered Nature of Turnaround Leadership in a Principal Preparation Program

    Science.gov (United States)

    Weiner, Jennie Miles; Burton, Laura J.

    2016-01-01

    In this study of nine participants in a turnaround principal preparation program, Jennie Miles Weiner and Laura J. Burton explore how gender role identity shaped participants' views of effective principal leadership and their place within it. The authors find that although female and male participants initially framed effective leadership…

  5. Laboratory-based clinical audit as a tool for continual improvement: an example from CSF chemistry turnaround time audit in a South-African teaching hospital.

    Science.gov (United States)

    Imoh, Lucius C; Mutale, Mubanga; Parker, Christopher T; Erasmus, Rajiv T; Zemlin, Annalise E

    2016-01-01

    Timeliness of laboratory results is crucial to patient care and outcome. Monitoring turnaround times (TAT), especially for emergency tests, is important to measure the effectiveness and efficiency of laboratory services. Laboratory-based clinical audits reveal opportunities for improving quality. Our aim was to identify the most critical steps causing a high TAT for cerebrospinal fluid (CSF) chemistry analysis in our laboratory. A 6-month retrospective audit was performed. The duration of each operational phase across the laboratory work flow was examined. A process-mapping audit trail of 60 randomly selected requests with a high TAT was conducted and reasons for high TAT were tested for significance. A total of 1505 CSF chemistry requests were analysed. Transport of samples to the laboratory was primarily responsible for the high average TAT (median TAT = 170 minutes). Labelling accounted for most delays within the laboratory (median TAT = 71 minutes) with most delays occurring after regular work hours (P audit identified sample transportation, work shift periods and use of inappropriate CSF sample tubes as drivers of high TAT for CSF chemistry in our laboratory. The results of this audit will be used to change pre-analytical practices in our laboratory with the aim of improving TAT and customer satisfaction.

  6. Constraints in the use of repair half times and mathematical modelling for the clinical application of HDR and PDR treatment schedules as an alternative for LDR brachytherapy

    International Nuclear Information System (INIS)

    Pop, L.A.M.; Broek, J.F.C.M. van den; Visser, A.G.; Kogel, A.J. van der

    1996-01-01

    Using theoretical models based on radiobiological principles for the design of new treatment schedules for HDR and PDR brachytherapy, it is important to realise the impact of assumptions regarding the kinetics of repair. Extrapolations based on longer repair half times in a continuous LDR reference scheme may lead to the calculation of dangerously high doses for alternative HDR and PDR treatment schedules. We used the clinical experience obtained with conventional ERT and LDR brachytherapy in head and neck cancer as a clinical guideline to check the impact of the radiobiological parameters used. Biologically equivalent dose (BED) values for the in clinical practice of LDR brachytherapy recommended dose of 65-70 Gy (prescribed at a dose rate between 30-50 cGy/h) are calculated as a function of the repair half time. These BED values are compared with the biological effect of a clinical reference dose of conventional ERT with 2 Gy/day and complete repair between the fractions. From this comparison of LDR and ERT treatment schedules, a range of values for the repair half times of acute or late responding tissues is demarcated with a reasonable fit to the clinical data. For the acute effects (or tumor control) the best fits are obtained for repair half times of about 0.5 h, while for late effects the repair half times are at least 1 h and can be as high as 3 h. Within these ranges of repair half times for acute and late effects, the outcome of 'alternative' HDR or PDR treatment schedules are discussed. It is predominantly the late reacting normal tissue with the longer repair half time for which problems will be encountered and no or only marginal gain is to be expected of decreasing the dose rate per pulse in PDR brachytherapy

  7. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  8. Balancing burn-in and mission times in environments with catastrophic and repairable failures

    International Nuclear Information System (INIS)

    Bebbington, Mark; Lai, C.-D.; Zitikis, Ricardas

    2009-01-01

    In a system subject to both repairable and catastrophic (i.e., nonrepairable) failures, 'mission success' can be defined as operating for a specified time without a catastrophic failure. We examine the effect of a burn-in process of duration τ on the mission time x, and also on the probability of mission success, by introducing several functions and surfaces on the (τ,x)-plane whose extrema represent suitable choices for the best burn-in time, and the best burn-in time for a desired mission time. The corresponding curvature functions and surfaces provide information about probabilities and expectations related to these burn-in and mission times. Theoretical considerations are illustrated with both parametric and, separating the failures by failure mode, nonparametric analyses of a data set, and graphical visualization of results.

  9. Turnaround strategies for companies in crisis: Watch out the causes of decline before firing people

    Directory of Open Access Journals (Sweden)

    Monica Santana

    2017-07-01

    Full Text Available When a company goes into crisis, the first and most typical response is the dismissal of people, even before considering the sources of the decline. Although the reduction of costs may seem a quick and reasonable measure in this context, downsizing is not the only possibility, nor the most advisable response when facing decline. In turn, by identifying and understanding the sources of decline in time, a company may want to decide on human resource (HR alternatives to layoffs. This research shows how the HR responses of declining companies should be in line with the sources of the decline. Adopting a configurational perspective, we propose a model of analysis that links sources of decline, turnaround strategy, and HR strategy (HRS and practices. This model identifies four basic HRS for organizations in decline, according to its sources: flexibility-oriented, efficiency-oriented, niche-oriented, and maintenance-oriented HRS.

  10. Biomechanical Analysis of an Arthroscopic Broström Ankle Ligament Repair and a Suture Anchor-Augmented Repair.

    Science.gov (United States)

    Giza, Eric; Whitlow, Scott R; Williams, Brady T; Acevedo, Jorge I; Mangone, Peter G; Haytmanek, C Thomas; Curry, Eugene E; Turnbull, Travis Lee; LaPrade, Robert F; Wijdicks, Coen A; Clanton, Thomas O

    2015-07-01

    Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair. © The Author(s) 2015.

  11. Reliability analysis for a circular consecutive-2-out-of-n:F repairable system with priority in repair

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Zuo, Ming J.; Yam, Richard C.M.

    2000-01-01

    A circular consecutive-2-out-of-n:F repairable system with one repairman is studied in this paper. When there are more than one failed component, priorities are assigned to the failed components. Both the working time and the repair time of each component is assumed to be exponentially distributed. Every component after repair is as good as new. By using the definition of generalized transition probability and the concept of critical component, we derive the state transition probability matrix of the system. Methodologies are then presented for the derivation of system reliability indexes such as availability, rate of occurrence of failure, mean time between failures, reliability, and mean time to first failure

  12. Relationship of DNA repair and chromosome aberrations to potentially lethal damage repair in X-irradiated mammalian cells

    International Nuclear Information System (INIS)

    Fornace, A.J. Jr.; Nagasawa, H.; Little, J.B.

    1980-01-01

    By the alkaline elution technique, the repair of x-ray-induced DNA single strand breaks and DNA-protein cross-links was investigated in stationary phase, contact-inhibited mouse cells. During the first hour of repair, approximately 90% of x-ray induced single strand breaks were rejoined whereas most of the remaining breaks were rejoined more slowly during the next 5 h. The number of residual non-rejoined single strand breaks was approximately proportional to the x-ray dose at early repair times. DNA-protein cross-links were removed at a slower rate - T 1/2 approximately 10 to 12 h. Cells were subcultured at low density at various times after irradiation and scored for colony survival, and chromosome aberrations in the first mitosis after sub-culture. Both cell lethality and the frequency of chromosome aberrations decreased during the first several hours of repair, reaching a minimum level by 6 h; this decrease correlated temporally with the repair of the slowly rejoining DNA strand breaks. The possible relationship of DNA repair to changes in survival and chromosome aberrations is discussed

  13. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    Science.gov (United States)

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  14. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time-efficien......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time...

  15. Conformational Analysis of DNA Repair Intermediates by Time-Resolved Fluorescence Spectroscopy

    OpenAIRE

    Lin, Su; Horning, David P.; Szostak, Jack W.; Chaput, John C.

    2009-01-01

    DNA repair enzymes are essential for maintaining the integrity of the DNA sequence. Unfortunately, very little is known about how these enzymes recognize damaged regions along the helix. Structural analysis of cellular repair enzymes bound to DNA reveals that these enzymes are able to recognize DNA in a variety of conformations. However, the prevalence of these deformations in the absence of enzymes remains unclear, as small populations of DNA conformations are often difficult to detect by NM...

  16. Germany's energy turnaround. A joint venture for the future

    International Nuclear Information System (INIS)

    2011-01-01

    The Ethics Committee is sure that nuclear phaseout will be possible within a decade with the energy turnaround measures presented here. Nuclear phaseout is considered necessary and is recommended with the intention to prevent the risk of nuclear power in Germany and to use less risky technologies. The competitive standing of the German industry should not be affected. Science and research, new technologies and the readiness of German industrial organizations to develop new business models for a sustainable economy provides Germany with alternatives, i.e. wind power, solar, hydroelectric, geothermal, biomass, efficient energy use and higher energy efficiency, as well as fossil fuels used with low emissions of climate-relevant gases. Further, a changed human lifestyle with more respect of nature will help to save energy. In the first stage of nuclear phaseout, nuclear power plants will be shut down and decommissioned. Of course, the Ethics Committee is aware that after this stage, there will be long years of intensive work of shielding, saveguarding and finally dismantling.

  17. Umbilical Hernia Repair and Pregnancy: Before, during, after…

    Directory of Open Access Journals (Sweden)

    Hakan Kulacoglu

    2018-01-01

    Full Text Available Umbilical hernias are most common in women than men. Pregnancy may cause herniation or render a preexisting one apparent, because of progressively raised intra-abdominal pressure. The incidence of umbilical hernia among pregnancies is 0.08%. Surgical algorithm for a pregnant woman with a hernia is not thoroughly clear. There is no consensus about the timing of surgery for an umbilical hernia in a woman either who is already pregnant or planning a pregnancy. If the hernia is incarcerated or strangulated at the time of diagnosis, an emergency repair is inevitable. If the hernia is not complicated, but symptomatic an elective repair should be proposed. When the patient has a small and asymptomatic hernia it may be better to postpone the repair until she gives birth. If the hernia is repaired by suture alone, a high risk of recurrence exists during pregnancy. Umbilical hernia repair during pregnancy can be performed with minimal morbidity to the mother and baby. Second trimester is a proper timing for surgery. Asymptomatic hernias can be repaired, following childbirth or at the time of cesarean section (C-section. Elective repair after childbirth is possible as early as postpartum of eighth week. A 1-year interval can give the patient a very smooth convalescence, including hormonal stabilization and return to normal body weight. Moreover, surgery can be postponed for a longer time even after another pregnancy, if the patients would like to have more children. Diastasis recti are very frequent in pregnancy. It may persist in postpartum period. A high recurrence risk is expected in patients with rectus diastasis. This risk is especially high after suture repairs. Mesh repairs should be considered in this situation.

  18. Hepatopancreaticobiliary Values after Thoracoabdominal Aneurysm Repair

    Science.gov (United States)

    Wu, Darrell; Coselli, Joseph S.; Johnson, Michael L.; LeMaire, Scott A.

    2014-01-01

    Background: After thoracoabdominal aortic aneurysm (TAAA) repair, blood tests assessing hepatopancreaticobiliary (HPB) organs commonly have abnormal results. The clinical significance of such abnormalities is difficult to determine because the expected postoperative levels have not been characterized. Therefore, we sought to establish expected trends in HPB laboratory values after TAAA repair. Methods: This 5-year study comprised 155 patients undergoing elective Crawford extent II TAAA repair. In accordance with a prospective study protocol, all repairs involved left-sided heart bypass, selective visceral perfusion, and cold renal perfusion. Blood levels of aspartate transaminase (AST), alanine transaminase (ALT), γ-glutamyl transpeptidase (GGT), lactate dehydrogenase (LDH), total bilirubin, amylase, and lipase were measured before TAAA repair and for 7 days afterward. Ratios between postoperative and baseline levels were compared for each time point with 95% confidence intervals. Results: Temporal patterns for the laboratory values varied greatly. Amylase, lipase, and AST underwent significant early increases before decreasing to preoperative levels. LDH increased immediately and remained significantly elevated, whereas ALT increased more gradually. GGT remained near baseline through postoperative day 4, and then increased to more than twice baseline. Total bilirubin never differed significantly from baseline. After adjusted analysis, the ischemic time predicted the maximum AST, lipase, GGT, and LDH values. Conclusions: Although most HPB laboratory values increase significantly after elective TAAA repair, the temporal trends for different values vary substantially. The ischemic time predicts the maximum AST, lipase, GGT, and LDH levels. These trends should be considered when laboratory values are assessed after TAAA repair. PMID:26798731

  19. Electron Transfer Mechanisms of DNA Repair by Photolyase

    Science.gov (United States)

    Zhong, Dongping

    2015-04-01

    Photolyase is a flavin photoenzyme that repairs two DNA base damage products induced by ultraviolet (UV) light: cyclobutane pyrimidine dimers and 6-4 photoproducts. With femtosecond spectroscopy and site-directed mutagenesis, investigators have recently made significant advances in our understanding of UV-damaged DNA repair, and the entire enzymatic dynamics can now be mapped out in real time. For dimer repair, six elementary steps have been characterized, including three electron transfer reactions and two bond-breaking processes, and their reaction times have been determined. A unique electron-tunneling pathway was identified, and the critical residues in modulating the repair function at the active site were determined. The dynamic synergy between the elementary reactions for maintaining high repair efficiency was elucidated, and the biological nature of the flavin active state was uncovered. For 6-4 photoproduct repair, a proton-coupled electron transfer repair mechanism has been revealed. The elucidation of electron transfer mechanisms and two repair photocycles is significant and provides a molecular basis for future practical applications, such as in rational drug design for curing skin cancer.

  20. Value maximizing maintenance policies under general repair

    International Nuclear Information System (INIS)

    Marais, Karen B.

    2013-01-01

    One class of maintenance optimization problems considers the notion of general repair maintenance policies where systems are repaired or replaced on failure. In each case the optimality is based on minimizing the total maintenance cost of the system. These cost-centric optimizations ignore the value dimension of maintenance and can lead to maintenance strategies that do not maximize system value. This paper applies these ideas to the general repair optimization problem using a semi-Markov decision process, discounted cash flow techniques, and dynamic programming to identify the value-optimal actions for any given time and system condition. The impact of several parameters on maintenance strategy, such as operating cost and revenue, system failure characteristics, repair and replacement costs, and the planning time horizon, is explored. This approach provides a quantitative basis on which to base maintenance strategy decisions that contribute to system value. These decisions are different from those suggested by traditional cost-based approaches. The results show (1) how the optimal action for a given time and condition changes as replacement and repair costs change, and identifies the point at which these costs become too high for profitable system operation; (2) that for shorter planning horizons it is better to repair, since there is no time to reap the benefits of increased operating profit and reliability; (3) how the value-optimal maintenance policy is affected by the system's failure characteristics, and hence whether it is worthwhile to invest in higher reliability; and (4) the impact of the repair level on the optimal maintenance policy. -- Highlights: •Provides a quantitative basis for maintenance strategy decisions that contribute to system value. •Shows how the optimal action for a given condition changes as replacement and repair costs change. •Shows how the optimal policy is affected by the system's failure characteristics. •Shows when it is

  1. Success of Meniscal Repair at ACL Reconstruction

    Science.gov (United States)

    Toman, Charles; Spindler, Kurt P.; Dunn, Warren R.; Amendola, Annunziata; Andrish, Jack T.; Bergfeld, John A.; Flanigan, David; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Huston, Laura J.; Harrell, Frank E.; Wright, Rick W.

    2013-01-01

    Background Meniscal repair is performed in an attempt to prevent posttraumatic arthritis resulting from meniscal dysfunction after meniscal tears. The socioeconomic implications of premature arthritis are significant in the young patient population. Investigations and techniques focusing on meniscus preservation and healing are now at the forefront of orthopaedic sports medicine. Hypothesis Concomitant meniscal repair with ACL reconstruction is a durable and successful procedure at two year follow-up. Study Design Case Series; Level of evidence, 4. Methods All unilateral primary ACL reconstructions entered in 2002 in a prospective cohort who had meniscal repair at the time of ACLR were evaluated. Validated patient oriented outcome instruments were completed preoperatively and then again at the two-year postoperative time point. Reoperation after the index procedure was also documented and confirmed by operative reports. Results 437 unilateral primary ACL reconstructions were performed with 86 concomitant meniscal repairs (57 medial, 29 lateral) in 84 patients during the study period. Patient follow-up was obtained on 94% (81/86) of the meniscal repairs, allowing confirmation of meniscal repair success (defined as no repeat arthroscopic procedure) or failure. The overall success rate for meniscal repairs was 96% (76/79 patients) at two-year follow-up. Conclusions Meniscal repair is a successful procedure in conjunction with ACL reconstruction. When confronted with a “repairable” meniscal tear at the time of ACL reconstruction, orthopaedic surgeons can expect an estimated >90% clinical success rate at two-year follow-up using a variety of methods as shown in our study. PMID:19465734

  2. Procedures for maintenance and repairs

    International Nuclear Information System (INIS)

    Pickel, E.

    1981-01-01

    After a general review of the operation experience in the history of more than 12 operating years, the organization in the plant will be shown with special aspect to quality assurance, capacity of the workshops and connected groups as radiation protection, chemical laboratories etc. The number, time intervals and manpower effort for the repeating tests will be discussed. Reasons and examples for back-fitting activities in the plant are given. Besides special repair and maintenance procedures as repair of the steam generators, in-service inspection of the reactor pressure vessel, repair of a feed-water pipe and repair of the core structure in the pressure vessel, the general system to handle maintenance and repair-work in the KWO-plant will be shown. This includes also the detailed planning of the annual refueling and revision of the plant. (orig./RW)

  3. Laparoscopic inguinal hernia repair: gold standard in bilateral hernia repair? Results of more than 2800 patients in comparison to literature.

    Science.gov (United States)

    Wauschkuhn, Constantin Aurel; Schwarz, Jochen; Boekeler, Ulf; Bittner, Reinhard

    2010-12-01

    Advantages and disadvantages of open and endoscopic hernia surgery are still being discussed. Until now there has been no study that evaluated the advantages and disadvantages of bilateral hernia repair in a large number of patients. Our prospectively collected database was analyzed to compare the results of laparoscopic bilateral with laparoscopic unilateral hernia repair. We then compared these results with the results of a literature review regarding open and laparoscopic bilateral hernia repair. From April 1993 to December 2007 there were 7240 patients with unilateral primary hernia (PH) and 2880 patients with bilateral hernia (5760 hernias) who underwent laparoscopic transabdominal preperitoneal patch plastic (TAPP). Of the 10,120 patients, 28.5% had bilateral hernias. Adjusted for the number of patients operated on, the mean duration of surgery for unilateral hernia repair was shorter than that for bilateral repair (45 vs. 70 min), but period of disability (14 vs. 14 days) was the same. Adjusted for the number of hernias repaired, morbidity (1.9 vs. 1.4%), reoperation (0.5 vs. 0.43%), and recurrence rate (0.63 vs. 0.42%) were similar for unilateral versus bilateral repair, respectively. The review of the literature shows a significantly shorter time out of work after laparoscopic bilateral repair than after the bilateral open approach. Simultaneous laparoscopic repair of bilateral inguinal hernias does not increase the risk for the patient and has an equal length of down time compared with unilateral repair. According to literature, recovery after laparoscopic repair is faster than after open simultaneous repair. Laparoscopic/endoscopic inguinal hernia repair of bilateral hernias should be recommended as the gold standard.

  4. Exteriorization or in-situ repair, comparison of options for uterine repair at cesarean delivery

    International Nuclear Information System (INIS)

    Zafar, B.; Shehzad, F.; Safdar, C.A.

    2016-01-01

    Objective of study is to compare peri-operative complications between exteriorization and intraabdominal repair of uterus after cesarean delivery. Study Design: Randomized controlled trial. Place and Duration of Study: Obstetrics and Gynecology Department of Pakistan Ordinance Factory Hospital, Wah Cantt, from 1st April 2010 to 30th September 2010. Material and Methods: Patients planned for 1st cesarean section under spinal anesthesia were randomly allocated by lottery method to exteriorized (A) or in situ uterine repair (B) group. Patients with history of uterine surgeries and cesarean section were excluded from study. Variables analyzed were operation time, peri-operative hemoglobin (Hb) fall, nausea and vomiting during the cesarean delivery. Results: The study analyzed 170 patients and divided them in 2 groups, having no significant difference with respect to maternal demographics, procedure statistics and indication of cesarean section. Significant difference was observed in operation time being 32.78 min in exteriorized group and 36.38 min in situ uterine repair group (p-value 0.0001). Hb percent fall was 0.85 g/dl and 0.92 g/dl respectively in both groups (p-value 0.62) Nausea and vomiting was 23.5 percent in group A and 11.8 percent in group B (p-value 0.02, 0.04 respectively) Conclusion: Peri-operative complications like operative time and Hb fall are less in uterine repair after temporary exteriorization as compared to intra-abdominal repair of uterus after cesarean delivery. Nausea and vomiting were increased in exteriorized group but proper regional anesthetic technique and achieving adequate analgesia can reduce patient discomfort. (author)

  5. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  6. Robotic Inguinal Hernia Repair: Technique and Early Experience.

    Science.gov (United States)

    Arcerito, Massimo; Changchien, Eric; Bernal, Oscar; Konkoly-Thege, Adam; Moon, John

    2016-10-01

    Laparoscopic inguinal hernia repair has been shown to have multiple advantages compared with open repair such as less postoperative pain and earlier resume of daily activities with a comparable recurrence rate. We speculate robotic inguinal hernia repair may yield equivalent benefits, while providing the surgeon added dexterity. One hundred consecutive robotic inguinal hernia repairs with mesh were performed with a mean age of 56 years (25-96). Fifty-six unilateral hernias and 22 bilateral hernias were repaired amongst 62 males and 16 females. Polypropylene mesh was used for reconstruction. All but, two patients were completed robotically. Mean operative time was 52 minutes per hernia repair (45-67). Five patients were admitted overnight based on their advanced age. Regular diet was resumed immediately. Postoperative pain was minimal and regular activity was achieved after an average of four days. One patient recurred after three months in our earlier experience and he was repaired robotically. Mean follow-up time was 12 months. These data, compared with laparoscopic approach, suggest similar recurrence rates and postoperative pain. We believe comparative studies with laparoscopic approach need to be performed to assess the role robotic surgery has in the treatment of inguinal hernia repair.

  7. Capturing tissue repair in zebrafish larvae with time-lapse brightfield stereomicroscopy.

    Science.gov (United States)

    Lisse, Thomas S; Brochu, Elizabeth A; Rieger, Sandra

    2015-01-31

    The zebrafish larval tail fin is ideal for studying tissue regeneration due to the simple architecture of the larval fin-fold, which comprises of two layers of skin that enclose undifferentiated mesenchyme, and because the larval tail fin regenerates rapidly within 2-3 days. Using this system, we demonstrate a method for capturing the repair dynamics of the amputated tail fin with time-lapse video brightfield stereomicroscopy. We demonstrate that fin amputation triggers a contraction of the amputation wound and extrusion of cells around the wound margin, leading to their subsequent clearance. Fin regeneration proceeds from proximal to distal direction after a short delay. In addition, developmental growth of the larva can be observed during all stages. The presented method provides an opportunity for observing and analyzing whole tissue-scale behaviors such as fin development and growth in a simple microscope setting, which is easily adaptable to any stereomicroscope with time-lapse capabilities.

  8. Regulatory Challenges for Cartilage Repair Technologies.

    Science.gov (United States)

    McGowan, Kevin B; Stiegman, Glenn

    2013-01-01

    In the United States, few Food and Drug Administration (FDA)-approved options exist for the treatment of focal cartilage and osteochondral lesions. Developers of products for cartilage repair face many challenges to obtain marketing approval from the FDA. The objective of this review is to discuss the necessary steps for FDA application and approval for a new cartilage repair product. FDA Guidance Documents, FDA Panel Meetings, scientific organization recommendations, and clinicaltrials.gov were reviewed to demonstrate the current thinking of FDA and the scientific community on the regulatory process for cartilage repair therapies. Cartilage repair therapies can receive market approval from FDA as medical devices, drugs, or biologics, and the specific classification of product can affect the nonclinical, clinical, and regulatory strategy to bring the product to market. Recent FDA guidance gives an outline of the required elements to bring a cartilage repair product to market, although these standards are often very general. As a result, companies have to carefully craft their study patient population, comparator group, and clinical endpoint to best showcase their product's attributes. In addition, regulatory strategy and manufacturing process validation need to be considered early in the clinical study process to allow for timely product approval following the completion of clinical study. Although the path to regulatory approval for a cartilage repair therapy is challenging and time-consuming, proper clinical trial planning and attention to the details can eventually save companies time and money by bringing a product to the market in the most expeditious process possible.

  9. 'A Stitch in Time?':Repairs and Rejection in Sale of Goods

    OpenAIRE

    Hood, Parker

    2008-01-01

    Section 35(6)(a) says there is no acceptance of goods (and, hence, no loss of the right to reject) where a defective good is repaired, pursuant to 'an arrangement with the seller'. However, what is the position where the seller, having repaired the goods, does not tell the buyer what the fault was or what was done to rectify it? In such a case, the House of Lords has held the buyer can still reject the goods, even where the seller says they are 'as good as new'. The basis for doing so was an ...

  10. DNA repair in neurons: So if they don't divide what's to repair?

    International Nuclear Information System (INIS)

    Fishel, Melissa L.; Vasko, Michael R.; Kelley, Mark R.

    2007-01-01

    Neuronal DNA repair remains one of the most exciting areas for investigation, particularly as a means to compare the DNA repair response in mitotic (cancer) vs. post-mitotic (neuronal) cells. In addition, the role of DNA repair in neuronal cell survival and response to aging and environmental insults is of particular interest. DNA damage caused by reactive oxygen species (ROS) such as generated by mitochondrial respiration includes altered bases, abasic sites, and single- and double-strand breaks which can be prevented by the DNA base excision repair (BER) pathway. Oxidative stress accumulates in the DNA of the human brain over time especially in the mitochondrial DNA (mtDNA) and is proposed to play a critical role in aging and in the pathogenesis of several neurological disorders including Parkinson's disease, ALS, and Alzheimer's diseases. Because DNA damage accumulates in the mtDNA more than nuclear DNA, there is increased interest in DNA repair pathways and the consequence of DNA damage in the mitochondria of neurons. The type of damage that is most likely to occur in neuronal cells is oxidative DNA damage which is primarily removed by the BER pathway. Following the notion that the bulk of neuronal DNA damage is acquired by oxidative DNA damage and ROS, the BER pathway is a likely area of focus for neuronal studies of DNA repair. BER variations in brain aging and pathology in various brain regions and tissues are presented. Therefore, the BER pathway is discussed in greater detail in this review than other repair pathways. Other repair pathways including direct reversal, nucleotide excision repair (NER), mismatch repair (MMR), homologous recombination and non-homologous end joining are also discussed. Finally, there is a growing interest in the role that DNA repair pathways play in the clinical arena as they relate to the neurotoxicity and neuropathy associated with cancer treatments. Among the numerous side effects of cancer treatments, major clinical effects

  11. The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments.

    Science.gov (United States)

    Austin, Jodie A; Smith, Ian R; Tariq, Amina

    2018-01-22

    Closed-loop electronic medication management systems (EMMS) are recognised as an effective intervention to improve medication safety, yet evidence of their effectiveness in hospitals is limited. Few studies have compared medication turnaround time for a closed-loop electronic versus paper-based medication management environment. To compare medication turnaround times in a paper-based hospital environment with a digital hospital equipped with a closed-loop EMMS, consisting of computerised physician order entry, profiled automated dispensing cabinets packaged with unit dose medications and barcode medication administration. Data were collected during 2 weeks at three private hospital sites (one with closed-loop EMMS) within the same organisation network in Queensland, Australia. Time between scheduled and actual administration times was analysed for first dose of time-critical and non-critical medications located on the ward or sourced via pharmacy. Medication turnaround times at the EMMS site were less compared to the paper-based sites (median, IQR: 35 min, 8-57 min versus 120 min, 30-180 min, P medications, 77% were administered within 60 min of scheduled time at the EMMS site versus 38% for the paper-based sites. Similar difference was observed for non-critical medications, 80% were administered within 60 min of their scheduled time at the EMMS site versus 41% at the paper-based facilities. The study indicates medication turnaround times utilising a closed-loop EMMS are less compared to paper-based systems. This improvement may be attributable to increased accessibility of medications using automated dispensing cabinets and electronic medication administration records flagging tasks to nurses in real time. © 2018 Royal Pharmaceutical Society.

  12. An apology for primary repair of tetralogy of Fallot.

    Science.gov (United States)

    Van Arsdell, Glen; Yun, Tae-Jin

    2005-01-01

    The first repair of tetralogy of Fallot (TOF) was 50 years ago, so it would seem that the details for optimal management strategies would be clear. Timing of repair and operative repair strategy for TOF are still a source of debate. Varying institutions have published excellent outcomes with a primary repair strategy or a selective staged repair strategy. In this article, the current and historic strategy for repair of TOF at the Hospital for Sick Children in Toronto is delineated along with associated outcomes. Data from our institution indicate a clear survival advantage for primary repair of TOF.

  13. Pulse frequency in pulsed brachytherapy based on tissue repair kinetics

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Koedooder, Kees; Tienhoven, Geertjan van; Blank, Leo E.C.M.; Gonzalez Gonzalez, Dionisio

    1998-01-01

    Purpose: Investigation of normal tissue sparing in pulsed brachytherapy (PB) relative to continuous low-dose rate irradiation (CLDR) by adjusting pulse frequency based on tissue repair characteristics. Method: Using the linear quadratic model, the relative effectiveness (RE) of a 20 Gy boost was calculated for tissue with an α/β ratio ranging from 2 to 10 Gy and a half-time of sublethal damage repair between 0.1 and 3 h. The boost dose was considered to be delivered either in a number of pulses varying from 2 to 25, or continuously at a dose rate of 0.50, 0.80, or 1.20 Gy/h. Results: The RE of 20 Gy was found to be identical for PB in 25 pulses of 0.80 Gy each h and CLDR delivered at 0.80 Gy/h for any α/β value and for a repair half-time > 0.75 h. When normal tissue repair half-times are assumed to be longer than tumor repair half-times, normal tissue sparing can be obtained, within the restriction of a fixed overall treatment time, with higher dose per pulse and longer period time (time elapsed between start of pulse n and start of pulse n + 1). An optimum relative normal tissue sparing larger than 10% was found with 4 pulses of 5 Gy every 8 h. Hence, a therapeutic gain might be obtained when changing from CLDR to PB by adjusting the physical dose in such a way that the biological dose on the tumor is maintained. The normal tissue-sparing phenomenon can be explained by an increase in RE with longer period time for tissue with high α/β ratio and fast or intermediate repair half-time, and the RE for tissue with low α/β ratio and long repair half-time remains almost constant. Conclusion: Within the benchmark of the LQ model, advantage in normal tissue-sparing is expected when matching the pulse frequency to the repair kinetics of the normal tissue exposed. A period time longer than 1 h may lead to a reduction of late normal tissue complications. This theoretical advantage emphasizes the need for better knowledge of human tissue-repair kinetics

  14. Role of DNA repair in repair of cytogenetic damages. Contribution of repair of single-strand DNA breaks to cytogenetic damages repair

    International Nuclear Information System (INIS)

    Rozanova, O.M.; Zaichkina, S.I.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    The comparison was made between the results of the effect of poly(ADP-ribosylation) ingibitors (e.g. nicotinamide and 3-aminobenzamide) and a chromatin proteinase ingibitor, phenylmethylsulfonylfluoride, on the cytogenetic damages repair, by a micronuclear test, and DNA repair in Chinese hamster fibroblasts. The values of the repair half-periods (5-7 min for the cytogenetic damages and 5 min for the rapidly repaired DNA damages) and a similar modyfying effect with regard to radiation cytogenetic damages and kynetics of DNA damages repair were found to be close. This confirms the contribution of repair of DNA single-strand breaks in the initiation of structural damages to chromosomes

  15. Biological effect of pulsed dose rate brachytherapy with stepping sources if short half-times of repair are present in tissues

    International Nuclear Information System (INIS)

    Fowler, Jack F.; Limbergen, Erik F.M. van

    1997-01-01

    Purpose: To explore the possible increase of radiation effect in tissues irradiated by pulsed brachytherapy (PDR) for local tissue dose rates between those 'averaged over the whole pulse' and the instantaneous high dose rates close to the dwell positions. Increased effect is more likely for tissues with short half-times of repair of the order of a few minutes, similar to pulse durations. Methods and Materials: Calculations were done assuming the linear quadratic formula for radiation damage, in which only the dose-squared term is subject to exponential repair. The situation with two components of T (1(2)) is addressed. A constant overall time of 140 h and a constant total dose of 70 Gy were assumed throughout, the continuous low dose rate of 0.5 Gy/h (CLDR) providing the unitary standard effects for each PDR condition. Effects of dose rates ranging from 4 Gy/h to 120 Gy/h (HDR at 2 Gy/min) were studied, covering the gap in an earlier publication. Four schedules were examined: doses per pulse of 0.5, 1, 1.5, and 2 Gy given at repetition frequencies of 1, 2, 3, and 4 h, respectively, each with a range of assumed half-times of repair of 4 min to 1.5 h. Results are presented for late-responding tissues, the differences from CLDR being two or three times greater than for early-responding tissues and most tumors. Results: Curves are presented relating the ratio of increased biological effect (proportional to log cell kill) calculated for PDR relative to CLDR. Ratios as high as 1.5 can be found for large doses per pulse (2 Gy) if the half-time of repair in tissues is as short as a few minutes. The major influences on effect are dose per pulse, half-time of repair in tissue, and--when T (1(2)) is short--the instantaneous dose rate. Maximum ratios of PDR/CLDR occur when the dose rate is such that pulse duration is approximately equal to T (1(2)) . As dose rate in the pulse is increased, a plateau of effect is reached, for most T (1(2)) s, above 10 to 20 Gy/h, which is

  16. DNA repair

    International Nuclear Information System (INIS)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals

  17. Investigation of DNA damage and repair mechanism using deinococcus radiodurans

    International Nuclear Information System (INIS)

    Lau How Mooi; Kikuchi, M.; Kobayashi, Y.; Narumi, I.; Watanabe, H.

    1997-01-01

    Deninococcus Radiodurans, formerly known as Micrococcus Radiodurans, is a popular bacterium because of its high resistance to damage by carcinogens such as ionizing radiation (Dean et. al. 1966; Kitayama and Matsuyama 1968) and UV radiation (Gasvon et. al., 1995; Arrange et. al. 1993). In this report, we investigated the high resistance to ionizing radiation by this bacterium. The bacteria had been exposed from I to 5 kGy of gamma radiation and then incubated in TGY medium to study their ability to repair the broken DNA. The repair time was measured by Pulse Field Gel Electrophoresis (PFGE) method. The repair time for each dose was determined. Also in order to ensure that the repair was perfect, the bacterium was subjected to a second exposure of ionizing radiation after it has fully repaired. It was found that the 'second' repair characteristic was similar to the first repair. This confirmed that the repair after the exposure to the ionizing radiation was perfect

  18. 3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision.

    Science.gov (United States)

    Leon, Piera; Rivellini, Roberta; Giudici, Fabiola; Sciuto, Antonio; Pirozzi, Felice; Corcione, Francesco

    2017-04-01

    The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning ( P = .07). 3D vision in laparoscopic HH repair helps surgeon's visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.

  19. Cost-effectiveness of open versus arthroscopic rotator cuff repair.

    Science.gov (United States)

    Adla, Deepthi N; Rowsell, Mark; Pandey, Radhakant

    2010-03-01

    Economic evaluation of surgical procedures is necessary in view of more expensive newer techniques emerging in an increasingly cost-conscious health care environment. This study compares the cost-effectiveness of open rotator cuff repair with arthroscopic repair for moderately size tears. This was a prospective study of 30 consecutive patients, of whom 15 had an arthroscopic repair and 15 had an open procedure. Clinical effectiveness was assessed using Oxford and Constant shoulder scores. Costs were estimated from departmental and hospital financial data. At last follow-up, no difference Oxford and Constant shoulder scores was noted between the 2 methods of repair. There was no significant difference between the groups in the cost of time in the operating theater, inpatient time, amount of postoperative analgesia, number of postoperative outpatient visits, physiotherapy costs, and time off work. The incremental cost of each arthroscopic rotator cuff repair was pound675 ($1248.75) more than the open procedure. This was mainly in the area of direct health care costs, instrumentation in particular. Health care policy makers are increasingly demanding evidence of cost-effectiveness of a procedure. This study showed both methods of repair provide equivalent clinical results. Open cuff repair is more cost-effective than arthroscopic repair and is likely to have lower cost-utility ratio. In addition, the tariff for the arthroscopic procedure in some health care systems is same as open repair. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  20. An integrated production inventory model of deteriorating items subject to random machine breakdown with a stochastic repair time

    Directory of Open Access Journals (Sweden)

    Huynh Trung Luong

    2016-11-01

    Full Text Available In a continuous manufacturing environment where production and consumption occur simultaneously, one of the biggest challenges is the efficient management of production and inventory system. In order to manage the integrated production inventory system economically it is necessary to identify the optimal production time and the optimal production reorder point that either maximize the profit or minimize the cost. In addition, during production the process has to go through some natural phenomena like random breakdown of machine, deterioration of product over time, uncertainty in repair time that eventually create the possibility of shortage. In this situation, efficient management of inventory & production is crucial. This paper addresses the situation where a perishable (deteriorated product is manufactured and consumed simultaneously, the demand of this product is stable over the time, machine that produce the product also face random failure and the time to repair this machine is also uncertain. In order to describe this scenario more appropriately, the continuously reviewed Economic Production Quantity (EPQ model is considered in this research work. The main goal is to identify the optimal production uptime and the production reorder point that ultimately minimize the expected value of total cost consisting of machine setup, deterioration, inventory holding, shortage and corrective maintenance cost.

  1. Age replacement policy based on imperfect repair with random probability

    International Nuclear Information System (INIS)

    Lim, J.H.; Qu, Jian; Zuo, Ming J.

    2016-01-01

    In most of literatures of age replacement policy, failures before planned replacement age can be either minimally repaired or perfectly repaired based on the types of failures, cost for repairs and so on. In this paper, we propose age replacement policy based on imperfect repair with random probability. The proposed policy incorporates the case that such intermittent failure can be either minimally repaired or perfectly repaired with random probabilities. The mathematical formulas of the expected cost rate per unit time are derived for both the infinite-horizon case and the one-replacement-cycle case. For each case, we show that the optimal replacement age exists and is finite. - Highlights: • We propose a new age replacement policy with random probability of perfect repair. • We develop the expected cost per unit time. • We discuss the optimal age for replacement minimizing the expected cost rate.

  2. Potentially lethal damage and its repair

    International Nuclear Information System (INIS)

    Utsumi, Hiroshi

    1989-01-01

    Two forms termed fast-and slow-potentially lethal lethal damage (PLD) are introduced and discussed. The effect on the survival of x-irradiated Chinese hamster cells (V79) of two different post-treatments is examined in plateau- and in log-phases of growth. The postirradiation treatments used : a) incubation in hypertonic solution, and b) incubation in conditioned medium obtained from plateau-phase. Similar reduction in survival was caused by postirradiation treatment with hypertonic phosphate buffered saline, and similar increased in survival was effected by treatment in conditioned medium in plateau- and in log-phases cells. However, repair of PLD sensitive to hypertonic treatment was faster (half time, 5-10 min)(f-PLD repair) and independent from the repair of PLD (half time, 1-2 hour)(s-PLD repair) observed in conditioned medium. The results indicate the induction of two forms of PLD by radiation. Induction of both PLD was found to decrease with increasing LET of the radiation used. Identification of the molecular processes underlying repair and fixation of PLD is a task of particular interest, since it may allow replacement of a phenomenological definition with a molecular definition. Evidence is reviewed indicating the DNA double strand breaks (directly or indirectly induced) may be the DNA lesions underlying PLD. (author)

  3. Cost-Effectiveness of Emissions Reduction through Vehicle Repair Compared to CNG Conversion.

    Science.gov (United States)

    Guenther, Paul L; Lesko, Jon M; Stedman, Donald H

    1996-10-01

    In return for a temporary waiver from converting five vehicles to operate on compressed natural gas (CNG) for the Denver Clean Fuels program, the University of Denver identified, tested, repaired, and retested nine employee commuter vehicles. The results of the study validated the concept that employer-based identification and repair programs can be carried out in a cost-effective way. On average, each repaired vehicle removed fifty times more carbon monoxide (CO) emissions from Denver air than each CNG conversion. The average cost of each repair was eight times less than the average cost of each conversion. The average fuel economy benefit from the repairs was enough to pay for the average cost of repairs in less than three years of normal driving. When the expected lifetimes of repairs and conversions are included, the targeted repair program appears to be over sixty times more cost-effective as a CO emissions reduction strategy than CNG conversion.

  4. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian

    2016-03-25

    Data repairing aims at discovering and correcting erroneous data in databases. Traditional methods relying on predefined quality rules to detect the conflict between data may fail to choose the right way to fix the detected conflict. Recent efforts turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes the advantages of both rule-based method and crowd-based method. Particularly, we investigate the interaction between crowd-based repairing and rule-based repairing, and show that by doing crowd-based repairing to a small portion of values, we can greatly improve the repairing quality of the rule-based repairing method. Although we prove that the optimal interaction scheme using the least number of values for crowd-based repairing to maximize the imputation recall is not feasible to be achieved, still, our proposed solution identifies an efficient scheme through investigating the inconsistencies and the dependencies between values in the repairing process. Our empirical study on three data collections demonstrates the high repairing quality of CrowdAidRepair, as well as the efficiency of the generated interaction scheme over baselines.

  5. Systems Maintenance Automated Repair Tasks (SMART)

    Science.gov (United States)

    Schuh, Joseph; Mitchell, Brent; Locklear, Louis; Belson, Martin A.; Al-Shihabi, Mary Jo Y.; King, Nadean; Norena, Elkin; Hardin, Derek

    2010-01-01

    SMART is a uniform automated discrepancy analysis and repair-authoring platform that improves technical accuracy and timely delivery of repair procedures for a given discrepancy (see figure a). SMART will minimize data errors, create uniform repair processes, and enhance the existing knowledge base of engineering repair processes. This innovation is the first tool developed that links the hardware specification requirements with the actual repair methods, sequences, and required equipment. SMART is flexibly designed to be useable by multiple engineering groups requiring decision analysis, and by any work authorization and disposition platform (see figure b). The organizational logic creates the link between specification requirements of the hardware, and specific procedures required to repair discrepancies. The first segment in the SMART process uses a decision analysis tree to define all the permutations between component/ subcomponent/discrepancy/repair on the hardware. The second segment uses a repair matrix to define what the steps and sequences are for any repair defined in the decision tree. This segment also allows for the selection of specific steps from multivariable steps. SMART will also be able to interface with outside databases and to store information from them to be inserted into the repair-procedure document. Some of the steps will be identified as optional, and would only be used based on the location and the current configuration of the hardware. The output from this analysis would be sent to a work authoring system in the form of a predefined sequence of steps containing required actions, tools, parts, materials, certifications, and specific requirements controlling quality, functional requirements, and limitations.

  6. Laparoscopic repair of large suprapubic hernias.

    Science.gov (United States)

    Sikar, Hasan Ediz; Çetin, Kenan; Eyvaz, Kemal; Kaptanoglu, Levent; Küçük, Hasan Fehmi

    2017-09-01

    Suprapubic hernia is the term to describe ventral hernias located less than 4 cm above the pubic arch in the midline. Hernias with an upper margin above the arcuate line encounter technical difficulties, and the differences in repair methods forced us to define them as large suprapubic hernias. To present our experience with laparoscopic repair of large suprapubic hernias that allows adequate mesh overlap. Nineteen patients with suprapubic incisional hernias who underwent laparoscopic repair between May 2013 and January 2015 were included in the study. Patients with laparoscopic extraperitoneal repair who had a suprapubic hernia with an upper margin below the arcuate line were excluded. Two men and 17 women, with a mean age of 58.2, underwent laparoscopic repair. Most of the incisions were midline vertical (13/68.4%). Twelve (63.1%) of the patients had previous incisional hernia repair (PIHR group); the mean number of previous incisional hernia repair was 1.4. Mean defect size of the PIHR group was higher than in patients without previous repair - 107.3 cm 2 vs. 50.9 cm 2 (p < 0.05). Mean operating time of the PIHR group was higher than in patients without repair - 126 min vs. 77.9 min (p < 0.05). Although all complications occurred in the PIHR group, there was no statistically significant difference. Laparoscopic repair of large suprapubic hernias can be considered as the first option in treatment. The low recurrence rates reported in the literature and the lack of recurrence, as observed in our study, support this view.

  7. Exploiting global information in complex network repair processes

    Institute of Scientific and Technical Information of China (English)

    Tianyu WANG; Jun ZHANG; Sebastian WANDELT

    2017-01-01

    Robustness of complex networks has been studied for decades,with a particular focus on network attack.Research on network repair,on the other hand,has been conducted only very lately,given the even higher complexity and absence of an effective evaluation metric.A recently proposed network repair strategy is self-healing,which aims to repair networks for larger compo nents at a low cost only with local information.In this paper,we discuss the effectiveness and effi ciency of self-healing,which limits network repair to be a multi-objective optimization problem and makes it difficult to measure its optimality.This leads us to a new network repair evaluation metric.Since the time complexity of the computation is very high,we devise a greedy ranking strategy.Evaluations on both real-world and random networks show the effectiveness of our new metric and repair strategy.Our study contributes to optimal network repair algorithms and provides a gold standard for future studies on network repair.

  8. DNA repair related to radiation therapy

    International Nuclear Information System (INIS)

    Klein, W.

    1979-01-01

    The DNA excision repair capacity of peripheral human lymphocytes after radiation therapy has been analyzed. Different forms of application of the radiation during the therapy have been taken into account. No inhibition of repair was found if cells were allowed a certain amount of accomodation to radiation, either by using lower doses or longer application times. (G.G.)

  9. Repair of traumatized mammalian hair cells via sea anemone repair proteins.

    Science.gov (United States)

    Tang, Pei-Ciao; Smith, Karen Müller; Watson, Glen M

    2016-08-01

    Mammalian hair cells possess only a limited ability to repair damage after trauma. In contrast, sea anemones show a marked capability to repair damaged hair bundles by means of secreted repair proteins (RPs). Previously, it was found that recovery of traumatized hair cells in blind cavefish was enhanced by anemone-derived RPs; therefore, the ability of anemone RPs to assist recovery of damaged hair cells in mammals was tested here. After a 1 h incubation in RP-enriched culture media, uptake of FM1-43 by experimentally traumatized murine cochlear hair cells was restored to levels comparable to those exhibited by healthy controls. In addition, RP-treated explants had significantly more normally structured hair bundles than time-matched traumatized control explants. Collectively, these results indicate that anemone-derived RPs assist in restoring normal function and structure of experimentally traumatized hair cells of the mouse cochlea. © 2016. Published by The Company of Biologists Ltd.

  10. Sociology of the energy turnaround. Renewable energy sources and transition of rural regions; Soziologie der Energiewende. Erneuerbare Energien und die Transition des laendlichen Raums

    Energy Technology Data Exchange (ETDEWEB)

    Kunze, Conrad

    2012-11-01

    German politicians, industry and society are working on the 'energy turnaround'. While changes in centralized power generation and transmission are going slow, there is an increasing number of 'test laboratories' in rural regions as communities and villages abandon imported fossil fuels and generate their own power on the basis of solar, wind and geothermal resources. In his study, the author investigates the transition phase using tools of empirical sociology. He shows that local processes reflect the importance of the energy turnaround as a cultural change and as a full-scale transformation of rural regions. The development of local, decentral energy infrastructures is interpreted theoretically as an interdependence between social and technological compolexity. The further geographic diffusion of the model in German-language regions can thus be explained as a consequence of specific social structures.

  11. On a Batch Arrival Queuing System Equipped with a Stand-by Server during Vacation Periods or the Repairs Times of the Main Server

    Directory of Open Access Journals (Sweden)

    Rehab F. Khalaf

    2011-01-01

    Full Text Available We study a queuing system which is equipped with a stand-by server in addition to the main server. The stand-by server provides service to customers only during the period of absence of the main server when either the main server is on a vacation or it is in the state of repairs due to a sudden failure from time to time. The service times, vacation times, and repair times are assumed to follow general arbitrary distributions while the stand-by service times follow exponential distribution. Supplementary variables technique has been used to obtain steady state results in explicit and closed form in terms of the probability generating functions for the number of customers in the queue, the average number of customers, and the average waiting time in the queue while the MathCad software has been used to illustrate the numerical results in this work.

  12. Laparoscopic totally extraperitoneal inguinal hernia repair: lessons learned from 3,100 hernia repairs over 15 years.

    Science.gov (United States)

    Dulucq, Jean-Louis; Wintringer, Pascal; Mahajna, Ahmad

    2009-03-01

    Two revolutions in inguinal hernia repair surgery have occurred during the last two decades. The first was the introduction of tension-free hernia repair by Liechtenstein in 1989 and the second was the application of laparoscopic surgery to the treatment of inguinal hernia in the early 1990s. The purposes of this study were to assess the safety and effectiveness of laparoscopic totally extraperitoneal (TEP) repair and to discuss the technical changes that we faced on the basis of our accumulative experience. Patients who underwent an elective inguinal hernia repair at the Department of Abdominal Surgery at the Institute of Laparoscopic Surgery (ILS), Bordeaux, between June 1990 and May 2005 were enrolled retrospectively in this study. Patient demographic data, operative and postoperative course, and outpatient follow-up were studied. A total of 3,100 hernia repairs were included in the study. The majority of the hernias were repaired by TEP technique; the repair was done by transabdominal preperitoneal (TAPP) repair in only 3%. Eleven percent of the hernias were recurrences after conventional repair. Mean operative time was 17 min in unilateral hernia and 24 min in bilateral hernia. There were 36 hernias (1.2%) that required conversion: 12 hernias were converted to open anterior Liechtenstein and 24 to laparoscopic TAPP technique. The incidence of intraoperative complications was low. Most of the patients were discharged at the second day of the surgery. The overall postoperative morbidity rate was 2.2%. The incidence of recurrence rate was 0.35%. The recurrence rate for the first 200 repairs was 2.5%, but it decreased to 0.47% for the subsequent 1,254 hernia repairs According to our experience, in the hands of experienced laparoscopic surgeons, laparoscopic hernia repair seems to be the favored approach for most types of inguinal hernias. TEP is preferred over TAPP as the peritoneum is not violated and there are fewer intra-abdominal complications.

  13. On the optimal degree of imperfect repair

    International Nuclear Information System (INIS)

    Finkelstein, Maxim

    2015-01-01

    A simple cost-wise comparison between the minimal and perfect repair of a system is discussed first using a relevant example. The main focus of this note, however, is on imperfect (general) repair. The best repair for our system in this case is defined as the one that corresponds to the optimal level (extent) of repair actions that minimize the long-run expected cost per unit of time. This complex optimization problem is considered for a specific imperfect repair model (Kijima II), using the developed earlier asymptotic approach to the corresponding virtual age modelling. It is shown that the optimal solution exists when the failure rate of a system tends to infinity as t tends to infinity and the corresponding cost function decreases sufficiently fast. An example illustrating the optimization procedure is considered

  14. Imaging of the rabbit supraspinatus enthesis at 7 Tesla: a 4-week time course after repair surgery and effect of channeling.

    Science.gov (United States)

    Trudel, Guy; Melkus, Gerd; Cron, Greg O; Louati, Hakim; Sheikh, Adnan; Larson, Peder E Z; Schweitzer, Mark; Lapner, Peter; Uhthoff, Hans K; Laneuville, Odette

    2017-08-01

    To image the supraspinatus enthesis reformation of rabbit shoulders by magnetic resonance at 7 Tesla (T) using T2 mapping after surgical repair and to assess the effects of channeling aimed at enhancing enthesis reformation. In 112 rabbits, the distal supraspinatus (SSP) tendon was unilaterally detached and reattached after 1 week. At the first surgery, channeling was performed at the footprint in 64 rabbits. At the second surgery, the SSP tendon of all rabbits was re-attached to the greater tuberosity. The shoulders were harvested at 0, 1, 2, or 4 weeks after the repair surgery and were imaged at 7T. Quantitative T2 mapping was performed using multi slice two-dimensional multi-echo spin-echo sequence with fat saturation. Enthesis regions of interests were drawn on three slices at the footprint to measure T2 relaxation times. Tendon repair (F (2, 218)  = 44; P < 2.2e-16) and postoperative duration (F (3, 218)  = 4.8; P = 0.006) both affected significantly the T2 values while channeling had no significant effect. For the time effect, the only pair with a statistical difference was the 0-week and 4-week for the channeling groups (P = 0.023). Enthesis reformation early after surgical repair of the SSP distal tendon was characterized by increasing T2 values. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:461-467. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Repair-misrepair model of cell survival

    International Nuclear Information System (INIS)

    Tobias, C.A.; Blakely, E.A.; Ngo, F.Q.H.

    1980-01-01

    During the last three years a new model, the repair-misrepair model (RMR) has been proposed, to interpret radiobiological experiments with heavy ions. In using the RMR model it became apparent that some of its features are suitable for handling the effects produced by a variety of environmental agents in addition to ionizing radiation. Two separate sequences of events are assumed to take place in an irradiated cell. The first sequence begins with an initial energy transfer consisting of ionizations and excitations, culminating via fast secondary physical and chemical processes in established macromolecular lesions in essential cell structures. The second sequence contains the responses of the cell to the lesions and consists of the processes of recognition and molecular repair. In normal cells there exists one repair process or at most a few enzymatic repair processes for each essential macromolecular lesion. The enzymatic repair processes may last for hours and minutes, and can be separated in time from the initial physicochemical and later genetic phases

  16. Laparoscopic Repair of Inguinal Hernias

    OpenAIRE

    Carter, Jonathan; Duh, Quan-Yang

    2011-01-01

    For patients with recurrent inguinal hernia, or bilateral inguinal hernia, or for women, laparoscopic repair offers significant advantages over open techniques with regard to recurrence risk, pain, and recovery. For unilateral first-time hernias, either laparoscopic or open repair with mesh can offer excellent results. The major drawback of laparoscopy is that the technique requires a significant number of cases to master. For surgeons in group practice, it makes sense to have one surgeon in ...

  17. Last Time Buy and repair decisions for fast moving parts

    NARCIS (Netherlands)

    Behfard, S.; Al Hanbali, A.; van der Heijden, M. C.; Zijm, W. H.M.

    2018-01-01

    Spare part availability is essential for advanced capital goods with a long service period. Sourcing becomes challenging once the production of spare parts ceases, while the remaining service period is still long. In this paper, we focus on fast moving parts with repair of failed parts as an

  18. Subsequent Shoulder Surgery After Isolated Arthroscopic SLAP Repair.

    Science.gov (United States)

    Mollon, Brent; Mahure, Siddharth A; Ensor, Kelsey L; Zuckerman, Joseph D; Kwon, Young W; Rokito, Andrew S

    2016-10-01

    To quantify the incidence of and identify the risk factors for subsequent shoulder procedures after isolated SLAP repair. New York's Statewide Planning and Research Cooperative System database was searched between 2003 and 2014 to identify individuals with the sole diagnosis of a SLAP lesion who underwent isolated arthroscopic SLAP repair. Patients were longitudinally followed up for a minimum of 3 years to analyze for subsequent ipsilateral shoulder procedures. Between 2003 and 2014, 2,524 patients met our inclusion criteria. After 3 to 11 years of follow-up, 10.1% of patients (254 of 2,524) underwent repeat surgical intervention on the same shoulder as the initial SLAP repair. The mean time to repeat shoulder surgery was 2.3 ± 2.1 years. Subsequent procedures included subacromial decompression (35%), debridement (26.7%). repeat SLAP repair (19.7%), and biceps tenodesis or tenotomy (13.0%). After isolated SLAP repair, patients aged 20 years or younger were more likely to undergo arthroscopic Bankart repair (odds ratio [OR], 2.91; 95% confidence interval [CI], 1.36-6.21; P = .005), whereas age older than 30 years was an independent risk factor for subsequent acromioplasty (OR, 2.3; 95% CI, 1.4-3.7; P surgery after isolated SLAP repair, often related to an additional diagnosis, suggesting that clinicians should consider other potential causes of shoulder pain when considering surgery for patients with SLAP lesions. In addition, the number of isolated SLAP repairs performed has decreased over time, and management of failed SLAP repair has shifted toward biceps tenodesis or tenotomy over revision SLAP repair in more recent years. Level III, case-control study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Why shorter half-times of repair lead to greater damage in pulsed brachytherapy

    International Nuclear Information System (INIS)

    Fowler, J.F.

    1993-01-01

    Pulsed brachytherapy consists of replacing continuous irradiation at low dose-rate with a series of medium dose-rate fractions in the same overall time and to the same total dose. For example, pulses of 1 Gy given every 2 hr or 2 Gy given every 4 hr would deliver the same 70 Gy in 140 hr as continuous irradiation at 0.5 Gy/hr. If higher dose-rates are used, even with gaps between the pulses, the biological effects are always greater. Provided that dose rates in the pulse do not exceed 3 Gy/hr, and provided that pulses are given as often as every 2 hr, the inevitable increases of biological effect are no larger than a few percent (of biologically effective dose or extrapolated response dose). However, these increases are more likely to exceed 10% (and thus become clinically significant) if the half-time of repair of sublethal damage is short (less than 1 hr) rather than long. This somewhat unexpected finding is explained in detail here. The rise and fall of Biologically Effective Dose (and hence of Relative Effectiveness, for a constant dose in each pulse) is calculated during and after single pulses, assuming a range of values of T 1/2 , the half-time of sublethal damage repair. The area under each curve is proportional to Biologically Effective Dose and therefore to log cell kill. Pulses at 3 Gy/hr do yield greater biological effect (dose x integrated Relative Effectiveness) than lower dose-rate pulses or continuous irradiation at 0.5 Gy/hr. The contrast is greater for the short T 1/2 of 0.5 hr than for the longer T 1/2 of 1.5 hr. More biological damage will be done (compared with traditional low dose rate brachytherapy) in tissues with short T 1/2 (0.1-1 hr) than in tissues with longer T 1/2 values. 8 refs., 3 figs

  20. Monopolies, liberalization, energy turnaround. (Dis)continuities in the electricity market design

    International Nuclear Information System (INIS)

    Grashof, Katherina; Zipp, Alexander; Jachmann, Henning; Wille-Haussmann, Bernhard; Lechtenboehmer, Stefan

    2015-01-01

    After a long period of stability, the electricity industry is in the past 15 years, in a major state of flux. First, the switching of state-monitored and regulated regional monopolies to liberalized producer and consumer markets. At the moment we are in a similar change from conventional to renewable energy production. Below the main question will be addressed whether the paradigms of the individual phases are compatible, which still have their place and which should be modified. Moreover, it is shown that the current market design of the future cannot be designed on a blank sheet, but existing structures have to be considered. Given the stage of monopolies, the liberalization and the started energy turnaround respectively in terms of their sector structure, dominant generation technologies, the interaction between production and load and characteristic elements of market design and regulation are presented. Subsequently, a preliminary answer is given to the question raised. [de

  1. An Efficient Algorithm for the Optimal Market Timing over Two Stocks

    Institute of Scientific and Technical Information of China (English)

    Hui Li; Hong-zhi An; Guo-fu Wu

    2004-01-01

    In this paper,the optimal trading strategy in timing the market by switching between two stocks is given.In order to deal with a large sample size with a fast turnaround computation time,we propose a class of recursive algorithm.A simulation is given to verify the efiectiveness of our method.

  2. Fragile DNA Repair Mechanism Reduces Ageing in Multicellular Model

    DEFF Research Database (Denmark)

    Bendtsen, Kristian Moss; Juul, Jeppe Søgaard; Trusina, Ala

    2012-01-01

    increases the amount of unrepaired DNA damage. Despite this vicious circle, we ask, can cells maintain a high DNA repair capacity for some time or is repair capacity bound to continuously decline with age? We here present a simple mathematical model for ageing in multicellular systems where cells subjected...... to DNA damage can undergo full repair, go apoptotic, or accumulate mutations thus reducing DNA repair capacity. Our model predicts that at the tissue level repair rate does not continuously decline with age, but instead has a characteristic extended period of high and non-declining DNA repair capacity......DNA damages, as well as mutations, increase with age. It is believed that these result from increased genotoxic stress and decreased capacity for DNA repair. The two causes are not independent, DNA damage can, for example, through mutations, compromise the capacity for DNA repair, which in turn...

  3. Epigenetic changes of DNA repair genes in cancer.

    Science.gov (United States)

    Lahtz, Christoph; Pfeifer, Gerd P

    2011-02-01

    'Every Hour Hurts, The Last One Kills'. That is an old saying about getting old. Every day, thousands of DNA damaging events take place in each cell of our body, but efficient DNA repair systems have evolved to prevent that. However, our DNA repair system and that of most other organisms are not as perfect as that of Deinococcus radiodurans, for example, which is able to repair massive amounts of DNA damage at one time. In many instances, accumulation of DNA damage has been linked to cancer, and genetic deficiencies in specific DNA repair genes are associated with tumor-prone phenotypes. In addition to mutations, which can be either inherited or somatically acquired, epigenetic silencing of DNA repair genes may promote tumorigenesis. This review will summarize current knowledge of the epigenetic inactivation of different DNA repair components in human cancer.

  4. Endoscope-assisted laparoscopic repair of perforated peptic ulcers.

    Science.gov (United States)

    Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh

    2004-04-01

    Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.

  5. A new model describing the curves for repair of both DNA double-strand breaks and chromosome damage

    International Nuclear Information System (INIS)

    Foray, N.; Badie, C.; Alsbeih, G.; Malaise, E.P.; Fertil, B.

    1996-01-01

    A review of reports dealing with fittings of the data for repair of DNA double-strand breaks (DSBs) and excess chromosome fragments (ECFs) shows that several models are used to fit the repair curves. Since DSBs and ECFs are correleated, it is worth developing a model describing both phenomena. The curve-fitting models used most extensively, the two repair half-times model for DSBs and the monoexponential plus residual model for ECFs, appear to be too inflexible to describe the repair curves for both DSBs and ECFs. We have therefore developed a new concept based on a variable repair half-time. According to this concept, the repair curve is continuously bending and dependent on time and probably reflects a continuous spectrum of damage repairability. The fits of the curves for DSB repair to the variable repair half-time and the variable repair half-time plus residual models were compared to those obtained with the two half-times plus residual and two half-times models. Similarly, the fits of the curves for ECF repair to the variable repair half-time and variable half-time plus residual models were compared to that obtained with the monoexponential plus residual model. The quality of fit and the dependence of adjustable parameters on the portion of the curve fitted were used as comparison criteria. We found that: (a) It is useful to postulate the existence of a residual term for unrepairable lesions, regardless of the model adopted. (b) With the two cell lines tested (a normal and a hypersensitive one), data for both DSBs and ECTs are best fitted to the variable repair half-time plus residual model, whatever the repair time range. 47 refs., 3 figs., 3 tabs

  6. A New Real-Time Cycle Slip Detection and Repair Method under High Ionospheric Activity for a Triple-Frequency GPS/BDS Receiver.

    Science.gov (United States)

    Liu, Wanke; Jin, Xueyuan; Wu, Mingkui; Hu, Jie; Wu, Yun

    2018-02-01

    Cycle slip detection and repair is a prerequisite for high-precision global navigation satellite system (GNSS)-based positioning. With the modernization and development of GNSS systems, more satellites are available to transmit triple-frequency signals, which allows the introduction of additional linear combinations and provides new opportunities for cycle slip detection and repair. In this paper, we present a new real-time cycle slip detection and repair method under high ionospheric activity for undifferenced Global Positioning System (GPS)/BeiDou Navigation Satellite System (BDS) triple-frequency observations collected with a single receiver. First, three optimal linearly independent geometry-free pseudorange minus phase combinations are selected to correctly and uniquely determine the cycle slips on the original triple-frequency carrier phase observations. Then, a second-order time-difference algorithm is employed for the pseudorange minus phase combinations to mitigate the impact of between-epoch ionospheric residuals on cycle slip detection, which is especially beneficial under high ionospheric activity. The performance of the approach is verified with static GPS/BDS triple-frequency observations that are collected with a 30 s sampling interval under active ionospheric conditions, and observations are manually inserted with simulated cycle slips. The results show that the method can correctly detect and repair cycle slips at a resolution as small as 1 cycle. Moreover, kinematic data collected from car-driven and airborne experiments are also processed to verify the performance of the method. The experimental results also demonstrate that the method is effective in processing kinematic data.

  7. DNA repair in neurons: So if they don't divide what's to repair?

    Energy Technology Data Exchange (ETDEWEB)

    Fishel, Melissa L. [Department of Pediatrics (Section of Hematology/Oncology), Herman B Wells Center for Pediatric Research, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States); Vasko, Michael R. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, 1044 W. Walnut St., Indianapolis, IN 46202 (United States); Kelley, Mark R. [Department of Pediatrics (Section of Hematology/Oncology), Herman B Wells Center for Pediatric Research, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States) and Department of Pharmacology and Toxicology, Indiana University School of Medicine, 1044 W. Walnut St., Indianapolis, IN 46202 (United States) and Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States)]. E-mail: mkelley@iupui.edu

    2007-01-03

    Neuronal DNA repair remains one of the most exciting areas for investigation, particularly as a means to compare the DNA repair response in mitotic (cancer) vs. post-mitotic (neuronal) cells. In addition, the role of DNA repair in neuronal cell survival and response to aging and environmental insults is of particular interest. DNA damage caused by reactive oxygen species (ROS) such as generated by mitochondrial respiration includes altered bases, abasic sites, and single- and double-strand breaks which can be prevented by the DNA base excision repair (BER) pathway. Oxidative stress accumulates in the DNA of the human brain over time especially in the mitochondrial DNA (mtDNA) and is proposed to play a critical role in aging and in the pathogenesis of several neurological disorders including Parkinson's disease, ALS, and Alzheimer's diseases. Because DNA damage accumulates in the mtDNA more than nuclear DNA, there is increased interest in DNA repair pathways and the consequence of DNA damage in the mitochondria of neurons. The type of damage that is most likely to occur in neuronal cells is oxidative DNA damage which is primarily removed by the BER pathway. Following the notion that the bulk of neuronal DNA damage is acquired by oxidative DNA damage and ROS, the BER pathway is a likely area of focus for neuronal studies of DNA repair. BER variations in brain aging and pathology in various brain regions and tissues are presented. Therefore, the BER pathway is discussed in greater detail in this review than other repair pathways. Other repair pathways including direct reversal, nucleotide excision repair (NER), mismatch repair (MMR), homologous recombination and non-homologous end joining are also discussed. Finally, there is a growing interest in the role that DNA repair pathways play in the clinical arena as they relate to the neurotoxicity and neuropathy associated with cancer treatments. Among the numerous side effects of cancer treatments, major

  8. O Turnaround da Empresa com Foco em Recursos e Capacidades: Um Estudo de Caso no Negócio de Alimentos

    Directory of Open Access Journals (Sweden)

    Carlos Vinnicius Silva

    2017-09-01

    Full Text Available O objetivo deste artigo é mostrar o que ocorre com os recursos e capacidades estratégicos envolvidos em um processo de turnaround visando à criação de valor para os clientes da empresa, sob a perspectiva da Visão Baseada em Recursos – VBR. Foi adotado o método de pesquisa qualitativo de caráter exploratório descritivo para o estudo de caso de uma empresa que é uma das principais multinacionais que operam globalmente no mercado de ingredientes para indústria de alimentos, atuando no segmento empresa-empresa. Foram entrevistados oito executivos da área de vendas, marketing, pesquisa e desenvolvimento, precificação e lucratividade e de cadeia de suprimentos que atuavam na empresa na época em que ocorreu o turnaround, com a aplicação de um roteiro padronizado com perguntas abertas. Os dados foram tratados com a utilização da Análise de Conteúdo. Foi constatado que a dificuldade para perceber as mudanças do mercado ocasionadas pelo aumento da concorrência e dos custos dos produtos, e o desconhecimento das necessidades dos clientes, se destacaram como as causas do declínio, ambas atribuídas à deficiência da gestão da empresa em antever e adaptar as estratégias às mudanças do cenário externo. O início do turnaround se deu com mudanças na equipe de liderança da empresa que provocou a revisão das estratégias que possibilitaram a retomada da vantagem competitiva. Os resultados da pesquisa indicam que os recursos, equipe comercial e conhecimento técnico, e as capacidades, mudança de mindset e sinergia entre as áreas da empresa, foram decisivos para o sucesso das estratégias adotadas.

  9. Cell cycle age dependence for radiation-induced G2 arrest: evidence for time-dependent repair

    International Nuclear Information System (INIS)

    Rowley, R.

    1985-01-01

    Exponentially growing eucaryotic cells, irradiated in interphase, are delayed in progression to mitosis chiefly by arrest in G 2 . The sensitivity of Chinese hamster ovary cells to G 2 arrest induction by X rays increases through the cell cycle, up to the X-ray transition point (TP) in G 2 . This age response can be explained by cell cycle age-dependent changes in susceptibility of the target(s) for G 2 arrest and/or by changes in capability for postirradiation recovery from G 2 arrest damage. Discrimination between sensitivity changes and repair phenomena is possible only if the level of G 2 arrest-causing damage sustained by a cell at the time of irradiation and the level ultimately expressed as arrest can be determined. The ability of caffeine to ameliorate radiation-induced G 2 arrest, while inhibiting repair of G 2 arrest-causing damage makes such an analysis possible. In the presence of caffeine, progression of irradiated cells was relatively unperturbed, but on caffeine removal, G 2 arrest was expressed. The duration of G 2 arrest was independent of the length of the prior caffeine exposure. This finding indicates that the target for G 2 arrest induction is present throughout the cell cycle and that the level of G 2 arrest damage incurred is initially constant for all cell cycle phases. The data are consistent with the existence of a time-dependent recovery mechanism to explain the age dependence for radiation induction of G 2 arrest

  10. Establishing Maximal Medical Improvement After Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Zuke, William A; Leroux, Timothy S; Gregory, Bonnie P; Black, Austin; Forsythe, Brian; Romeo, Anthony A; Verma, Nikhil N

    2018-03-01

    As health care transitions from a pay-for-service to a pay-for-performance infrastructure, the value of orthopaedic care must be defined accurately. Significant efforts have been made in defining quality and cost in arthroplasty; however, there remains a lag in ambulatory orthopaedic care. Two-year follow-up has been a general requirement for reporting outcomes after rotator cuff repair. However, this time requirement has not been established scientifically and is of increasing importance in the era of value-based health care. Given that arthroscopic rotator cuff repair is a common ambulatory orthopaedic procedure, the purpose of this study was to establish a time frame for maximal medical improvement (the state when improvement has stabilized) after arthroscopic rotator cuff repair. Systematic review. A systematic review of the literature was conducted, identifying studies reporting sequential patient-reported outcomes up to a minimum of 2 years after arthroscopic rotator cuff repair. The primary clinical outcome was patient-reported outcomes at 3-month, 6-month, 1-year, and 2-year follow-up. Secondary clinical outcomes included range of motion, strength, retears, and complications. Clinically significant improvement was determined between various time intervals by use of the minimal clinically important difference. The review included 19 studies including 1370 patients who underwent rotator cuff repair. Clinically significant improvement in patient-reported outcomes was seen up to 1 year after rotator cuff repair, but no clinical significance was noted from 1 year to 2 years. The majority of improvement in strength and range of motion was seen up to 6 months, but no clinically meaningful improvement was seen thereafter. All reported complications and the majority of retears occurred within 6 months after rotator cuff repair. After rotator cuff repair, a clinically significant improvement in patient-reported outcomes, range of motion, and strength was seen up to 1

  11. Solar thermal electricity production. A building block for the energy turnaround?; Solarthermische Stromerzeugung. Ein Baustein fuer die Energiewende?

    Energy Technology Data Exchange (ETDEWEB)

    Pitz-Paal, Robert [Deutsches Zentrum fuer Luft- und Raumfahrt (DLR) e.V., Koeln (Germany). Inst. fuer Solarforschung

    2012-12-15

    Whereas in Germany enthusiasm for solar thermal power plants has subsided following the inglorious insolvency of Solar Millennium AG, internationally the market is livening up again. This has to do with the fact that many countries have now understood that security of supply cannot be founded on photovoltaics and wind alone in the long term. Solar thermal power could thus yet become an important building block in Germany's energy supply system as it continues to pursue the energy turnaround.

  12. Is unilateral laparoscopic TEP inguinal hernia repair a job half done? The case for bilateral repair.

    Science.gov (United States)

    Pawanindra Lal; Philips, Prejesh; Chander, Jagdish; Ramteke, Vinod K

    2010-07-01

    Bilateral laparoscopic totally extraperitoneal (TEP) repair of unilateral hernia is conspicuous in published literature by its absence. There are no studies or data on the feasibility, advantages or disadvantages of bilateral repair in all cases or in any subset of patients with unilateral primary inguinal hernia. The objective of this study is to investigate the feasibility of bilateral laparoscopic exploration for all unilateral cases followed by laparoscopic TEP in all cases and to compare complications, recurrence rates, postoperative pain, patient satisfaction, and return to work retrospectively with a similar number of age-matched retrospective controls. One hundred fifty TEP operations were performed in 75 patients (group A) prospectively and were compared with 75 unilateral TEP operations (group B) in age-matched controls done previously by the same surgeon. All cases were performed under general anesthesia, and TEP repair was performed using three midline ports. All uncomplicated patients were discharged at 24 h, in keeping with departmental policy. Of 75 patients (group A), 25 (33.3%) were clinically diagnosed with bilateral hernia and the rest (50, 66.66%) with unilateral hernia. The distribution of the 25 bilateral cases was 11 bilateral direct and 14 bilateral indirect inguinal hernias. The distribution of the 75 age-matched controls (group B) was all unilateral hernia, of which 47 were right-sided and 28 were left-sided. There were 23 direct hernias and 52 indirect hernias among the control group. The mean operative time for all 150 cases was 76.66 +/- 15.92 min. The operative time in the control group (unilateral hernias) was 66.16 +/- 12.44 min, whereas the operative time in the test group (bilateral repair) was 87.2 +/- 11.32 min. The operative time in the bilateral group was significantly higher, by 21.04 min or 31.88% (p = 0.000). The operative time in the true unilateral group was 82.45 +/- 9.38 min, whereas the operative time in the former

  13. Impact of radiotherapy on PBMCs DNA repair capacity - Use of a multiplexed functional repair assay

    International Nuclear Information System (INIS)

    Sauvaigo, S.; Sarrazy, F.; Breton, J.; Caillat, S.; Chapuis, V.

    2012-01-01

    Radiation therapy is an essential part of cancer treatment as about 50% of patients will receive radiations at least once. Significant broad variation in radiosensitivity has been demonstrated in patients. About 5-10% of patients develop acute toxicity after radiotherapy. Therefore there is a need for the identification of markers able to predict the occurrence of adverse effects and thus adapt the radiotherapy regimen for radiosensitive patients. As a first step toward this goal, and considering the DNA repair defects associated with hypersensitivity radiation syndromes, we investigated the DNA repair phenotype of patients receiving radiotherapy. More precisely, we used a functional repair assay on support to follow the evolution of the glycosylases/AP endonuclease activities of PBMCs extracts of a series of patients during the time course of radiotherapy. For each patient, we collected one PBMCs sample before the first radiotherapy application (S1) and three samples after (S2 to S4) (one day and one week after application 1, and one at the end of the radiotherapy protocol). These four samples have been analysed for 11 donors. Clustering analyses of the results demonstrated a great heterogeneity of responses among the patients. Interestingly, this heterogeneity decreased between S1 and S4 where only 2 classes of patients remained if we except one patient that exhibited an atypical DNA repair phenotype. Furthermore, we showed that repair of several oxidized bases significantly increased between S1 and S3 or S4 (8oxoG, thymine glycol, A paired with 8oxoG), suggesting an adaptation of patients repair systems to the oxidative stress generated by the ionising radiations. Our preliminary results provided evidence that the DNA repair phenotype was impacted by the radiotherapy regimen. Further characterization of patients with known repair defects are needed to determine if atypical repair phenotypes could be associated with radiotherapy complications. Finally

  14. Optimal maintenance policies in incomplete repair models

    International Nuclear Information System (INIS)

    Kahle, Waltraud

    2007-01-01

    We consider an incomplete repair model, that is, the impact of repair is not minimal as in the homogeneous Poisson process and not 'as good as new' as in renewal processes but lies between these boundary cases. The repairs are assumed to impact the failure intensity following a virtual age process of the general form proposed by Kijima. In previous works field data from an industrial setting were used to fit several models. In most cases the estimated rate of occurrence of failures was that of an underlying exponential distribution of the time between failures. In this paper, it is shown that there exist maintenance schedules under which the failure behavior of the failure-repair process becomes a homogeneous Poisson process

  15. Repairable-conditionally repairable damage model based on dual Poisson processes.

    Science.gov (United States)

    Lind, B K; Persson, L M; Edgren, M R; Hedlöf, I; Brahme, A

    2003-09-01

    The advent of intensity-modulated radiation therapy makes it increasingly important to model the response accurately when large volumes of normal tissues are irradiated by controlled graded dose distributions aimed at maximizing tumor cure and minimizing normal tissue toxicity. The cell survival model proposed here is very useful and flexible for accurate description of the response of healthy tissues as well as tumors in classical and truly radiobiologically optimized radiation therapy. The repairable-conditionally repairable (RCR) model distinguishes between two different types of damage, namely the potentially repairable, which may also be lethal, i.e. if unrepaired or misrepaired, and the conditionally repairable, which may be repaired or may lead to apoptosis if it has not been repaired correctly. When potentially repairable damage is being repaired, for example by nonhomologous end joining, conditionally repairable damage may require in addition a high-fidelity correction by homologous repair. The induction of both types of damage is assumed to be described by Poisson statistics. The resultant cell survival expression has the unique ability to fit most experimental data well at low doses (the initial hypersensitive range), intermediate doses (on the shoulder of the survival curve), and high doses (on the quasi-exponential region of the survival curve). The complete Poisson expression can be approximated well by a simple bi-exponential cell survival expression, S(D) = e(-aD) + bDe(-cD), where the first term describes the survival of undamaged cells and the last term represents survival after complete repair of sublethal damage. The bi-exponential expression makes it easy to derive D(0), D(q), n and alpha, beta values to facilitate comparison with classical cell survival models.

  16. Tissue repair capacity and repair kinetics deduced from multifractionated or continuous irradiation regimens with incomplete repair

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.; Peters, L.J.

    1984-01-01

    A model is proposed for cell survival after multiple doses, when the interfraction interval is insufficient for complete Elkind repair. In the limit of ever-increasing number of ever-smaller fractional doses, the model transforms into the accumulation model of survival after continuous irradiation. When adapted to describe tissue responses to isoeffective multifractionated regimens, wherein repair is incomplete, a generalization of the usually linear plot of reciprocal total dose versus dose per fraction is obtained, in which downward curvature is evident. There is an advantage in studying tissue responses to multifractionated regimens with incomplete repair in the interfraction intervals, or continuous exposures at various dose rates since, in addition to determination of repair capacity, there is an estimate of repair kinetics. Results of analyses of previously published data are presented as illustration. Estimated from the response of three acutely responding normal tissues in the mouse (jejunum, colon and bone marrow), repair halftimes ranged from 0.3-0.9 h and values of β/delta were approximately 0.1 Gy -1 . From the response of mouse lung (LD50 for pneumonitis) to multifractionated regimens with incomplete repair, the repair halftime was estimated at 1.5 h and β/delta was 0.27 Gy -1 . In the rat spinal cord β/delta was 0.7 Gy -1 and Tsub(1/2) was 1.5 h. (U.K.)

  17. Non-parametric estimation of the availability in a general repairable system

    International Nuclear Information System (INIS)

    Gamiz, M.L.; Roman, Y.

    2008-01-01

    This work deals with repairable systems with unknown failure and repair time distributions. We focus on the estimation of the instantaneous availability, that is, the probability that the system is functioning at a given time, which we consider as the most significant measure for evaluating the effectiveness of a repairable system. The estimation of the availability function is not, in general, an easy task, i.e., analytical techniques are difficult to apply. We propose a smooth estimation of the availability based on kernel estimator of the cumulative distribution functions (CDF) of the failure and repair times, for which the bandwidth parameters are obtained by bootstrap procedures. The consistency properties of the availability estimator are established by using techniques based on the Laplace transform

  18. Non-parametric estimation of the availability in a general repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Gamiz, M.L. [Departamento de Estadistica e I.O., Facultad de Ciencias, Universidad de Granada, Granada 18071 (Spain)], E-mail: mgamiz@ugr.es; Roman, Y. [Departamento de Estadistica e I.O., Facultad de Ciencias, Universidad de Granada, Granada 18071 (Spain)

    2008-08-15

    This work deals with repairable systems with unknown failure and repair time distributions. We focus on the estimation of the instantaneous availability, that is, the probability that the system is functioning at a given time, which we consider as the most significant measure for evaluating the effectiveness of a repairable system. The estimation of the availability function is not, in general, an easy task, i.e., analytical techniques are difficult to apply. We propose a smooth estimation of the availability based on kernel estimator of the cumulative distribution functions (CDF) of the failure and repair times, for which the bandwidth parameters are obtained by bootstrap procedures. The consistency properties of the availability estimator are established by using techniques based on the Laplace transform.

  19. Mitral valve repair: an echocardiographic review: Part 2.

    Science.gov (United States)

    Maslow, Andrew

    2015-04-01

    Echocardiographic imaging of the mitral valve before and immediately after repair is crucial to the immediate and long-term outcome. Prior to mitral valve repair, echocardiographic imaging helps determine the feasibility and method of repair. After the repair, echocardiographic imaging displays the new baseline anatomy, assesses function, and determines whether or not further management is necessary. Three-dimensional imaging has improved the assessment of the mitral valve and facilitates communication with the surgeon by providing the surgeon with an image that he/she might see upon opening up the atrium. Further advancements in imaging will continue to improve the understanding of the function and dysfunction of the mitral valve both before and after repair. This information will improve treatment options, timing of invasive therapies, and advancements of repair techniques to yield better short- and long-term patient outcomes. The purpose of this review was to connect the echocardiographic evaluation with the surgical procedure. Bridging the pre- and post-CPB imaging with the surgical procedure allows a greater understanding of mitral valve repair.

  20. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material

    OpenAIRE

    Baums, M. H.; Buchhorn, G. H.; Spahn, G.; Poppendieck, B.; Schultz, W.; Klinger, H.-M.

    2008-01-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-...

  1. Magnetization transfer analysis of cartilage repair tissue: a preliminary study

    International Nuclear Information System (INIS)

    Palmieri, F.; Keyzer, F. de; Maes, F.; Breuseghem, I. van

    2006-01-01

    To evaluate the magnetization transfer ratio (MTR) after two different cartilage repair procedures, and to compare these data with the MTR of normal cartilage. Twenty-seven patients with a proven cartilage defect were recruited: 13 were treated with autologous chondrocyte implantation (ACI) and 14 were treated with the microfracture technique (MFR). All patients underwent MRI examinations with MT-sequences before the surgical treatment, after 12 months (26 patients) and after 24 months (11 patients). Eleven patients received a complete follow-up study at all three time points (five of the ACI group and six of the MFR group). All images were transferred to a workstation to calculate MTR images. For every MT image set, different ROIs were delineated by two radiologists. Means were calculated per ROI type in the different time frames and in both groups of cartilage repair. The data were analyzed with unpaired t- and ANOVA tests, and by calculating Pearson's correlation coefficient. No significant differences were found in the MTR of fatty bone marrow, muscle and normal cartilage in the different time frames. There was a significant but small difference between the MTR of normal cartilage and the cartilage repair area after 12 months for both procedures. After 24 months, the MTR of ACI repaired cartilage (0.31±0.07) was not significantly different from normal cartilage MTR (0.34±0.05). The MTR of MFR repaired cartilage (0.28±0.02), still showed a significant difference from normal cartilage. The differences between damaged and repaired cartilage MTR are too small to enable MT-imaging to be a useful tool for postoperative follow-up of cartilage repair procedures. There is, however, an evolution towards normal MTR-values in the cartilage repair tissue (especially after ACI repair). (orig.)

  2. Failure Modes in Concrete Repair Systems due to Ongoing Corrosion

    Directory of Open Access Journals (Sweden)

    Mladena Luković

    2017-01-01

    Full Text Available Corrosion of steel reinforcement is the main cause of deterioration in reinforced concrete structures. It can result in cracking and spalling of the concrete cover. After the damaged cover is repaired, reinforcement corrosion might continue and even accelerate. While the development of the corrosion cell is difficult to control, the damage can be possibly delayed and controlled by use of a suitable repair material. The lattice fracture model is used in this paper to investigate the performance of strain hardening cementitious composite (SHCC in concrete repair systems exposed to ongoing corrosion. Numerical results were verified by experimental tests when SHCC, nonreinforced material (repair mortar, and commercial repair mortar are used as repair materials. In experiments, reinforcement bars (surrounded by a repair material were exposed to accelerated corrosion tests. The influence of the substrate surface preparation, the type of repair material, the interface, and the substrate strength on the resulting damage and failure mode of repair systems are discussed. In general, SHCC repair enables distributed cracking with small crack widths, up to several times smaller compared to repair mortar. Furthermore, more warning signs prior to the final failure are present in the SHCC repair system.

  3. Inspection and repair of nuclear components

    International Nuclear Information System (INIS)

    Lahner, K.; Poetz, F.

    1993-01-01

    Despite careful design, manufacturing and operation, some of the important safety-relevant components show deterioration with time. Because of activation and contamination of these components, their inspection and repair has to be performed with manipulators. Some sophisticated manipulators are described, built by ABB Reaktor and used for inspection, maintenance and repair of PWR steam generators, fuel alignment pins, core baffle former bolts and reactor pressure vessel head penetrations. (Z.S.) 7 figs

  4. An automated repair method of water pipe infrastructure using carbon fiber bundles

    Science.gov (United States)

    Wisotzkey, Sean; Carr, Heath; Fyfe, Ed

    2011-04-01

    The United States water pipe infrastructure is made up of over 2 million miles of pipe. Due to age and deterioration, a large portion of this pipe is in need of repair to prevent catastrophic failures. Current repair methods generally involve intrusive techniques that can be time consuming and costly, but also can cause major societal impacts. A new automated repair method incorporating innovative carbon fiber technology is in development. This automated method would eliminate the need for trenching and would vastly cut time and labor costs, providing a much more economical pipe repair solution.

  5. On some steady-state characteristics of systems with gradual repair

    International Nuclear Information System (INIS)

    Finkelstein, Maxim; Ludick, Zani

    2014-01-01

    We consider a repairable system with continuous output that alternates between states of operation and repair. The output of the system in the operating state is represented by a continuous, decreasing function of time. We assume that during the repair state, the system can produce output that is modelled by an increasing stochastic process. The repair action gradually restores the output of the system to its initial level and it returns to the operating state. We obtain and analyse expressions for the generalized availability and related characteristics of systems with gradual repair and consider several meaningful examples

  6. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    OpenAIRE

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intra...

  7. Inhibition of DNA repair by trifluoperazine

    Energy Technology Data Exchange (ETDEWEB)

    Charp, P.A.; Regan, J.D.

    1985-01-01

    The authors examined the possible role of calmodulin in the excision repair of ultraviolet light-induced pyrimidine dimers in damaged DNA by means of specialized assay systems. These assays included bromodeoxyuridine photolysis, dimer chromatography and cytosine arabinoside incorporation in conjunction with hydroxyurea. The calmodulin antagonist, trifluoperazine, and the calcium-chelating agent, EGTA, were employed to ascertain what affect calmodulin played in the repair process. Normal human fibroblast cells are used in all studies described in this report. After exposure to 10 J/m2 of 254 nm light, the authors observed a decrease of about 30% in the number of single-strand breaks produced in the presence of 25 M trifluoperazine (1.9 vs. 3.3) in controls although the numbers of bases re-inserted in the repaired regions were similar (64 vs. 72). Measurement of thymine-containing dimers remaining throughout a 24 h time period indicated a 30% difference decrease in the number of cytosine arabinoside arrested repair sites in the presence of either EGTA or trifluoperazine. The results are discussed with relation to the possibility of calmodulin altering the initial incision by repair endonuclease. 27 references, 3 figures.

  8. Reliability analysis of Markov history-dependent repairable systems with neglected failures

    International Nuclear Information System (INIS)

    Du, Shijia; Zeng, Zhiguo; Cui, Lirong; Kang, Rui

    2017-01-01

    Markov history-dependent repairable systems refer to the Markov repairable systems in which some states are changeable and dependent on recent evolutional history of the system. In practice, many Markov history-dependent repairable systems are subjected to neglected failures, i.e., some failures do not affect system performances if they can be repaired promptly. In this paper, we develop a model based on the theory of aggregated stochastic processes to describe the history-dependent behavior and the effect of neglected failures on the Markov history-dependent repairable systems. Based on the developed model, instantaneous and steady-state availabilities are derived to characterize the reliability of the system. Four reliability-related time distributions, i.e., distribution for the k th working period, distribution for the k th failure period, distribution for the real working time in an effective working period, distribution for the neglected failure time in an effective working period, are also derived to provide a more comprehensive description of the system's reliability. Thanks to the power of the theory of aggregated stochastic processes, closed-form expressions are obtained for all the reliability indexes and time distributions. Finally, the developed indexes and analysis methods are demonstrated by a numerical example. - Highlights: • Markovian history-dependent repairable systems with neglected failures is modeled. • Aggregated stochastic processes are used to derive reliability indexes and time distributions. • Closed-form expressions are derived for the considered indexes and distributions.

  9. Repair/maintenance design for tokamak experimental fusion reactor

    International Nuclear Information System (INIS)

    1978-10-01

    Repair and maintenance design for JXFR has been studied. The reactor is in eight modules so that a damaged module alone can be separated from the other modules and transferred from the reactor room to a repair shop. Design work covers overhaul procedure, dismounting equipments (overhead cranes, auto welder/cutter and remote handling equipments), transport system of a module (module mounting carriages and rotating carriage), repair equipment for blanket, earthquake-proof analysis of the reactor, reactor room structure, repair shop layout, management of radioactive wastes, time and the number of persons required for overhaul etc. Though the repair and maintenance system is almost complete, there still remain problems for further study in joints of blanket cooling piping, auto welder/cutter and earthquake-proof strength in reactor disassemblage. More detailed studies and R and D are necessary for engineering perfection. (author)

  10. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  11. Rapid road repair vehicle

    Science.gov (United States)

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  12. Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.

    Science.gov (United States)

    Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak

    2014-09-01

    To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  13. We need an EEG 2.0. A law for the success of the energy policy turnaround

    International Nuclear Information System (INIS)

    Altmaier, Peter

    2014-01-01

    The contribution is discussing the development of renewable energies as a consequence of the energy policy turnaround in Germany. In the long term the cost of renewable will be lower than that of conventional energy sources. The challenges and chances of new technologies based on renewable energy and energy saving are identified, the new technologies could induce a new industrial revolution. The author clarifies the need for an advanced renewable energy law (EEG 2.0), including the necessity of a national consensus for an adequate extension of the national grid. The contribution includes recommendations with respect to the electricity prices and the requirement of a political framework.

  14. International Cartilage Repair Society (ICRS) Recommended Guidelines for Histological Endpoints for Cartilage Repair Studies in Animal Models and Clinical Trials

    Science.gov (United States)

    Hoemann, Caroline; Kandel, Rita; Roberts, Sally; Saris, Daniel B.F.; Creemers, Laura; Mainil-Varlet, Pierre; Méthot, Stephane; Hollander, Anthony P.; Buschmann, Michael D.

    2011-01-01

    Cartilage repair strategies aim to resurface a lesion with osteochondral tissue resembling native cartilage, but a variety of repair tissues are usually observed. Histology is an important structural outcome that could serve as an interim measure of efficacy in randomized controlled clinical studies. The purpose of this article is to propose guidelines for standardized histoprocessing and unbiased evaluation of animal tissues and human biopsies. Methods were compiled from a literature review, and illustrative data were added. In animal models, treatments are usually administered to acute defects created in healthy tissues, and the entire joint can be analyzed at multiple postoperative time points. In human clinical therapy, treatments are applied to developed lesions, and biopsies are obtained, usually from a subset of patients, at a specific time point. In striving to standardize evaluation of structural endpoints in cartilage repair studies, 5 variables should be controlled: 1) location of biopsy/sample section, 2) timing of biopsy/sample recovery, 3) histoprocessing, 4) staining, and 5) blinded evaluation with a proper control group. Histological scores, quantitative histomorphometry of repair tissue thickness, percentage of tissue staining for collagens and glycosaminoglycan, polarized light microscopy for collagen fibril organization, and subchondral bone integration/structure are all relevant outcome measures that can be collected and used to assess the efficacy of novel therapeutics. Standardized histology methods could improve statistical analyses, help interpret and validate noninvasive imaging outcomes, and permit cross-comparison between studies. Currently, there are no suitable substitutes for histology in evaluating repair tissue quality and cartilaginous character. PMID:26069577

  15. A novel sol-gel-derived calcium silicate cement with short setting time for application in endodontic repair of perforations.

    Science.gov (United States)

    Lee, Bor-Shiunn; Lin, Hong-Ping; Chan, Jerry Chun-Chung; Wang, Wei-Chuan; Hung, Ping-Hsuan; Tsai, Yu-Hsin; Lee, Yuan-Ling

    2018-01-01

    Mineral trioxide aggregate (MTA) is the most frequently used repair material in endodontics, but the long setting time and reduced mechanical strength in acidic environments are major shortcomings. In this study, a novel sol-gel-derived calcium silicate cement (sCSC) was developed using an initial Ca/Si molar ratio of 3, with the most effective mixing orders of reactants and optimal HNO 3 catalyst volumes. A Fourier transform infrared spectrometer, scanning electron microscope with energy-dispersive X-ray spectroscopy, and X-ray powder diffractometer were used for material characterization. The setting time, compressive strength, and microhardness of sCSC after hydration in neutral and pH 5 environments were compared with that of MTA. Results showed that sCSC demonstrated porous microstructures with a setting time of ~30 min, and the major components of sCSC were tricalcium silicate, dicalcium silicate, and calcium oxide. The optimal formula of sCSC was sn200, which exhibited significantly higher compressive strength and microhardness than MTA, irrespective of neutral or pH 5 environments. In addition, both sn200 and MTA demonstrated good biocompatibility because cell viability was similar to that of the control. These findings suggest that sn200 merits further clinical study for potential application in endodontic repair of perforations.

  16. Initial experience of laparoscopic incisional hernia repair.

    Science.gov (United States)

    Razman, J; Shaharin, S; Lukman, M R; Sukumar, N; Jasmi, A Y

    2006-06-01

    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.

  17. Epigenetic changes of DNA repair genes in cancer

    OpenAIRE

    Lahtz, Christoph; Pfeifer, Gerd P.

    2011-01-01

    ‘Every Hour Hurts, The Last One Kills'. That is an old saying about getting old. Every day, thousands of DNA damaging events take place in each cell of our body, but efficient DNA repair systems have evolved to prevent that. However, our DNA repair system and that of most other organisms are not as perfect as that of Deinococcus radiodurans, for example, which is able to repair massive amounts of DNA damage at one time. In many instances, accumulation of DNA damage has been linked to cancer, ...

  18. [Biomarkers of radiation-induced DNA repair processes].

    Science.gov (United States)

    Vallard, Alexis; Rancoule, Chloé; Guy, Jean-Baptiste; Espenel, Sophie; Sauvaigo, Sylvie; Rodriguez-Lafrasse, Claire; Magné, Nicolas

    2017-11-01

    The identification of DNA repair biomarkers is of paramount importance. Indeed, it is the first step in the process of modulating radiosensitivity and radioresistance. Unlike tools of detection and measurement of DNA damage, DNA repair biomarkers highlight the variations of DNA damage responses, depending on the dose and the dose rate. The aim of the present review is to describe the main biomarkers of radiation-induced DNA repair. We will focus on double strand breaks (DSB), because of their major role in radiation-induced cell death. The most important DNA repair biomarkers are DNA damage signaling proteins, with ATM, DNA-PKcs, 53BP1 and γ-H2AX. They can be analyzed either using immunostaining, or using lived cell imaging. However, to date, these techniques are still time and money consuming. The development of "omics" technologies should lead the way to new (and usable in daily routine) DNA repair biomarkers. Copyright © 2017 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  19. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    Science.gov (United States)

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  20. Arthroscopic undersurface rotator cuff repair versus conventional arthroscopic double-row rotator cuff repair - Comparable results at 2-year follow-up.

    Science.gov (United States)

    Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng

    2018-01-01

    The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.

  1. Implementation of a new 'community' laboratory CD4 service in a rural health district in South Africa extends laboratory services and substantially improves local reporting turnaround time.

    Science.gov (United States)

    Coetzee, L M; Cassim, N; Glencross, D K

    2015-12-16

    The CD4 integrated service delivery model (ITSDM) provides for reasonable access to pathology services across South Africa (SA) by offering three new service tiers that extend services into remote, under-serviced areas. ITSDM identified Pixley ka Seme as such an under-serviced district. To address the poor service delivery in this area, a new ITSDM community (tier 3) laboratory was established in De Aar, SA. Laboratory performance and turnaround time (TAT) were monitored post implementation to assess the impact on local service delivery. Using the National Health Laboratory Service Corporate Data Warehouse, CD4 data were extracted for the period April 2012-July 2013 (n=11,964). Total mean TAT (in hours) was calculated and pre-analytical and analytical components assessed. Ongoing testing volumes, as well as external quality assessment performance across ten trials, were used to indicate post-implementation success. Data were analysed using Stata 12. Prior to the implementation of CD4 testing at De Aar, the total mean TAT was 20.5 hours. This fell to 8.2 hours post implementation, predominantly as a result of a lower pre-analytical mean TAT reducing from a mean of 18.9 to 1.8 hours. The analytical testing TAT remained unchanged after implementation and monthly test volumes increased by up to 20%. External quality assessment indicated adequate performance. Although subjective, questionnaires sent to facilities reported improved service delivery. Establishing CD4 testing in a remote community laboratory substantially reduces overall TAT. Additional community CD4 laboratories should be established in under-serviced areas, especially where laboratory infrastructure is already in place.

  2. Investigation on shortening fabrication process of instrumented irradiation capsule of JMTR

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Inoue, Shuichi; Yamaura, Takayuki; Tsuchiya, Kunihiko; Nagao, Yoshiharu

    2013-06-01

    Refurbishment of The Japan Materials Testing Reactor (JMTR) was completed in FY2010. For damage caused by the 2011 off the Pacific coast of Tohoku Earthquake, the repair of facilities was completed in October 2012. Currently, the JMTR is in preparation for restart. Irradiation tests for LWRs safety research, science and technologies and production of RI for medical diagnosis medicine, etc. are expected after the JMTR restart. On the other hand, aiming at the attractive irradiation testing reactor, the usability improvement has been discussed. As a part of the usability improvement, shortening of turnaround time to get irradiation results from an application for irradiation use was discussed focusing on the fabrication process of irradiation capsules, where the fabrication process was analyzed and reviewed by referring a trial fabrication of the mockup capsule. As a result, it was found that the turnaround time can be shortened 2 months from fabrication period of 6 months with communize of irradiation capsule parts, application of ready-made instrumentation including the sheath heater, reconsideration of inspection process, etc. (author)

  3. DNA repair

    International Nuclear Information System (INIS)

    Van Zeeland, A.A.

    1984-01-01

    In this chapter a series of DNA repair pathways are discussed which are available to the cell to cope with the problem of DNA damaged by chemical or physical agents. In the case of microorganisms our knowledge about the precise mechanism of each DNA repair pathway and the regulation of it has been improved considerably when mutants deficient in these repair mechanisms became available. In the case of mammalian cells in culture, until recently there were very little repair deficient mutants available, because in almost all mammalian cells in culture at least the diploid number of chromosomes is present. Therefore the frequency of repair deficient mutants in such populations is very low. Nevertheless because replica plating techniques are improving some mutants from Chinese hamsters ovary cells and L5178Y mouse lymphoma cells are now available. In the case of human cells, cultures obtained from patients with certain genetic diseases are available. A number of cells appear to be sensitive to some chemical or physical mutagens. These include cells from patients suffering from xeroderma pigmentosum, Ataxia telangiectasia, Fanconi's anemia, Cockayne's syndrome. However, only in the case of xeroderma pigmentosum cells, has the sensitivity to ultraviolet light been clearly correlated with a deficiency in excision repair of pyrimidine dimers. Furthermore the work with strains obtained from biopsies from man is difficult because these cells generally have low cloning efficiencies and also have a limited lifespan in vitro. It is therefore very important that more repair deficient mutants will become available from established cell lines from human or animal origin

  4. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    Science.gov (United States)

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Radiation- and drug-induced DNA repair in mammalian oocytes and embryos

    International Nuclear Information System (INIS)

    Pedersen, R.A.; Brandriff, B.

    1979-01-01

    A review of studies showing ultraviolet- or drug-induced unscheduled DNA synthesis in mammalian oocytes and embryos suggests that the female gamete has an excision repair capacity from the earliest stages of oocyte growth. The oocyte's demonstrable excision repair capacity decreases at the time of meiotic maturation for unknown reasons, but the fully mature oocyte maintans a repair capacity, in contrast to the mature sperm, and contributes this to the zygote. Early embryo cells maintain relatively constant levels of excision repair until late fetal stages, when they lose their capacity for excision repair. These apparent changes in excision repair capacity do not have a simple relationship to known differences in radiation sensitivity of germ cells and embryos

  6. Involvement of sensory neurons in bone defect repair in rats

    International Nuclear Information System (INIS)

    Henmi, Akiko; Nakamura, Megumi; Echigo, Seishi; Sasano, Yasuyuki

    2011-01-01

    We investigated bone repair in sensory-denervated rats, compared with controls, to elucidate the involvement of sensory neurons. Nine-week-old male Wistar rats received subcutaneous injections of capsaicin to denervate sensory neurons. Rats treated with the same amount of vehicle served as controls. A standardized bone defect was created on the parietal bone. We measured the amount of repaired bone with quantitative radiographic analysis and the mRNA expressions of osteocalcin and cathepsin K with real-time polymerase chain reaction (PCR). Quantitative radiographic analysis showed that the standard deviations and coefficients of variation for the amount of repaired bone were much higher in the capsaicin-treated group than in the control group at any time point, which means that larger individual differences in the amount of repaired bone were found in capsaicin-treated rats than controls. Furthermore, radiographs showed radiolucency in pre-existing bone surrounding the standardized defect only in the capsaicin-treated group, and histological observation demonstrated some multinuclear cells corresponding to the radiolucent area. Real-time PCR indicated that there was no significant difference in the mRNA expression levels of osteocalcin and cathepsin K between the control group and the capsaicin-treated group. These results suggest that capsaicin-induced sensory denervation affects the bone defect repair. (author)

  7. The Effect of Cleft Lip and Palate, and the Timing of Lip Repair on Mother-Infant Interactions and Infant Development

    Science.gov (United States)

    Murray, Lynne; Hentges, Francoise; Hill, Jonathan; Karpf, Janne; Mistry, Beejal; Kreutz, Marianne; Woodall, Peter; Moss, Tony; Goodacre, Tim

    2008-01-01

    Background: Children with cleft lip and palate are at risk for psychological problems. Difficulties in mother-child interactions may be relevant, and could be affected by the timing of lip repair. Method: We assessed cognitive development, behaviour problems, and attachment in 94 infants with cleft lip (with and without cleft palate) and 96…

  8. 7 CFR 58.214 - General construction, repair and installation.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false General construction, repair and installation. 58.214... Service 1 Equipment and Utensils § 58.214 General construction, repair and installation. All equipment and utensils necessary to the manufacture of dry milk products, including pasteurizer, timing-pump or device...

  9. Repair in normal tissues and the possible relevance to radiotherapy

    International Nuclear Information System (INIS)

    Field, S.B.; Hornsey, S.

    1977-01-01

    Between each fraction in radiotherapy, there is repair and recovery of both normal and neoplastic tissues. Several different types of repair have been identified. Some relate specifically to the effect of changing the number of fractions and others to the overall treatment time. Each will be discussed and particular attention will be paid to slow repair phenomena which have recently been the subject of much interest. (orig.) [de

  10. Repair of abasic sites in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Dianov, Grigory L.; Sleeth, Kate M.; Dianova, Irina I.; Allinson, Sarah L

    2003-10-29

    Repair of both normal and reduced AP sites is activated by AP endonuclease, which recognizes and cleaves a phosphodiester bond 5' to the AP site. For a short period of time an incised AP site is occupied by poly(ADP-ribose) polymerase and then DNA polymerase {beta} adds one nucleotide into the repair gap and simultaneously removes the 5'-sugar phosphate. Finally, the DNA ligase III/XRCC1 complex accomplishes repair by sealing disrupted DNA ends. However, long-patch BER pathway, which is involved in the removal of reduced abasic sites, requires further DNA synthesis resulting in strand displacement and the generation of a damage-containing flap that is later removed by the flap endonuclease. Strand-displacement DNA synthesis is accomplished by DNA polymerase {delta}/{epsilon} and DNA ligase I restores DNA integrity. DNA synthesis by DNA polymerase {delta}/{epsilon} is dependent on proliferating cell nuclear antigen, which also stimulates the DNA ligase I and flap endonuclease. These repair events are supported by multiple protein-protein interactions.

  11. Optimal preventive maintenance and repair policies for multi-state systems

    International Nuclear Information System (INIS)

    Sheu, Shey-Huei; Chang, Chin-Chih; Chen, Yen-Luan; George Zhang, Zhe

    2015-01-01

    This paper studies the optimal preventive maintenance (PM) policies for multi-state systems. The scheduled PMs can be either imperfect or perfect type. The improved effective age is utilized to model the effect of an imperfect PM. The system is considered as in a failure state (unacceptable state) once its performance level falls below a given customer demand level. If the system fails before a scheduled PM, it is repaired and becomes operational again. We consider three types of major, minimal, and imperfect repair actions, respectively. The deterioration of the system is assumed to follow a non-homogeneous continuous time Markov process (NHCTMP) with finite state space. A recursive approach is proposed to efficiently compute the time-dependent distribution of the multi-state system. For each repair type, we find the optimal PM schedule that minimizes the average cost rate. The main implication of our results is that in determining the optimal scheduled PM, choosing the right repair type will significantly improve the efficiency of the system maintenance. Thus PM and repair decisions must be made jointly to achieve the best performance

  12. Paediatric laparoscopic hernia repair: Ex vivo skills in the reduced training era

    Directory of Open Access Journals (Sweden)

    Chris Parsons

    2013-01-01

    Full Text Available Introduction: Changes to surgical working hours have resulted in shorter training times and fewer learning opportunities. Tools that develop surgical skills ex-vivo are of particular interest in this era. Laparoscopic skills are regarded as essential by many for modern paediatric surgery practice. Several generic skills models have been reported and validated. However, there is limited evidence regarding the role of procedure specific models. Here, a laparoscopic paediatric hernia repair model is trialled with surgical trainees and their competence compared with consultant colleagues. Patients and Methods: An ex-vivo paediatric inguinal hernia repair model was devised. Surgical trainees from 5 specialist centres were recruited and performed multiple standardised repairs. Results: 23 trainees performed 192 repairs. Experts performed 10 repairs for comparison. Trainees were timed performing the repair and their accuracy measured. With repeated attempts trainee′s timings and accuracy improved until by the 10 th repair they were no different from benchmark consultant scores. Conclusion: A simple, procedure specific ex-vivo training model has been evaluated for laparoscopic hernia training in paediatric surgery. The results suggest improvements in competence with repetition. Trainee and benchmark consultant scores are no different by the 10 th trainee attempt. We conclude that this model may have a valuable role in the training and assessment of future paediatric surgeons.

  13. Personal exposure to benzene and 1,3-butadiene during petroleum refinery turnarounds and work in the oil harbour.

    Science.gov (United States)

    Akerstrom, M; Almerud, P; Andersson, E M; Strandberg, B; Sallsten, G

    2016-11-01

    Petroleum refinery workers' exposure to the carcinogens benzene and 1,3-butadiene has decreased during normal operations. However, certain occupational groups or events at the refineries still involve a risk of higher exposures. The aim of this study was to examine the personal exposure to benzene and 1,3-butadiene at refinery turnarounds and during work in the oil harbour. Personal exposure measurements of benzene and 1,3-butadiene were taken during work shifts, with a priori assumed higher benzene exposure, using PerkinElmer diffusive samplers filled with Carbopack X. Mean exposure levels were calculated, and repeated exposure measurements, when available, were assessed using mixed effect models. Group and individual compliance with the Swedish occupational exposure limit (OEL) was tested for the different exposure groups. Mean benzene exposure levels for refinery workers during the three measured turnarounds were 150, 610 and 960 µg/m 3 , and mean exposures for oil harbour workers and sewage tanker drivers were 310 and 360 µg/m 3 , respectively. Higher exposures were associated with handling benzene-rich products. Most occupational groups did not comply with the Swedish OEL for benzene nor did the individuals within the groups. The exposure to 1,3-butadiene was very low, between Work within the petroleum refinery industry, with potential exposure to open product streams containing higher fractions of benzene, pose a risk of personal benzene exposures exceeding the OEL. Refinery workers performing these work tasks frequently, such as contractors, sewage tanker drivers and oil harbour workers, need to be identified and protected.

  14. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  15. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Repair kinetics in tissues

    International Nuclear Information System (INIS)

    Thames, H.D.

    1989-01-01

    Monoexponential repair kinetics is based on the assumption of a single, dose-independent rate of repair of sublethal injury in the target cells for tissue injury after exposure to ionizing radiation. Descriptions of the available data based on this assumption have proved fairly successful for both acutely responding (skin, lip mucosa, gut) and late-responding (lung, spinal cord) normal tissues. There are indications of biphasic exponential repair in both categories, however. Unfortunately, the data usually lack sufficient resolution to permit unambiguous determination of the repair rates. There are also indications that repair kinetics may depend on the size of the dose. The data are conflicting on this account, however, with suggestions of both faster and slower repair after larger doses. Indeed, experiments that have been explicitly designed to test this hypothesis show either no effect (gut, spinal cord), faster repair after higher doses (lung, kidney), or slower repair after higher doses (skin). Monoexponential repair appears to be a fairly accurate description that provides an approximation to a more complicated picture, the elucidation of whose details will, however, require very careful and extensive experimental study. (author). 30 refs.; 1 fig

  17. Reducing turnaround time for laboratory test results does not improve retention of stable HIV-infected adults on POV program: experience from Uganda.

    Science.gov (United States)

    Maselle, Edna; Muhanguzi, Asaph; Muhumuza, Simon; Nansubuga, Jeniffer; Nawavvu, Cecilia; Namusobya, Jeniffer; Kamya, Moses R; Semitala, Fred C

    2014-01-01

    HIV/ AIDS clinics in resource limited settings (RLS) face increasing numbers of patients and workforce shortage [1, 2]. To address these challenges, efficient models of care like pharmacy only visits (POV) and nurse only visits (NOV) are recommended [3]. The Makerere University Joint AIDS Program (MJAP), a PEPFAR funded program providing care to over 42,000 HIV infected adults has implemented the POV model since 2009. In this model, stable patients on antiretroviral therapy (ART) with adherence to ART >95% and Karnofsky score >90% are reviewed by a doctor every four months but visit pharmacy for ART re-fills every two months. A study conducted in August 2011 showed low retention on the POV program with symptomatic diseases, pending CD4 count, complete blood count results, and poor adherence to ART as the major reasons for the non-retention in the POV program. To improve retention on POV, the TAT (Turnaround Time) for laboratory results (the main reason for non-retention in the previous study) was reduced from one month to one week. In August 2012, the study was repeated to assess the effect of reducing TAT on improving retention one year after patients were placed on POV. A cohort analysis of data from patients in August 2011 and in August 2012 on POV was done. We compared retention of POV before and after reducing the TAT for laboratory results. Retention on POV was 12.0% (95% CI 9.50-14.7) among 619 patients in 2011, (70% Females), mean age was 33 years, Standard Deviation (SD) 8.5 compared to 11.1% (95% CI 9.15-13.4) among 888 patients (70% Females), mean age 38.3 years, SD 8.9 in 2012 (p=0.59). The main reasons for non-retention on the POV program in 2012 were poor adherence to ART (23%) and missed clinic appointments (14%). Reducing TAT for laboratory test results did not improve retention of stable HIV-infected adults on POV in our clinic. Strategies for improving adherence to ART and keeping clinic appointments need to be employed to balance workload and

  18. Repair and replacement of reactor internals for plant life extension

    International Nuclear Information System (INIS)

    Graae, T.

    1998-01-01

    Recent experience from early Swedish BWRs corroborate that all components in a nuclear power plant can be repaired or replaced with new ones. Oskarshamn 1 has gone through a thorough refurbishment project. A number of internals were repaired or replaced including the core shroud support which was welded to the bottom of the reactor pressure vessel. The project verifies that it is fully possible to carry out complicated inspection and repair work inside a nuclear pressure vessel which has been in operation for more than 20 years. Along with increased capacity factor, operating nuclear power plants get the financial conditions needed for extensive repair and modernization projects. Large power output leads to short pay-back times for the investments. The FENIX project at Oskarshamn 1 is such a project. There are utilities whose policy is to keep their plants in as-new condition for an unlimited length of time. (orig.)

  19. A comparison of the DNA and chromosome repair kinetics after #betta# irradiation

    International Nuclear Information System (INIS)

    Hittelman, W.N.; Pollard, M.

    1982-01-01

    The kinetics of repair at the chromosome and DNA levels were compared after #betta# irradiation of Chinese hamster ovary cells (CHO). Induction and repair of DNA damage were measured by the alkaline and neutral elution techniques, while chromosome damage and repair were determined by the technique of premature chromosome condensation. During and after #betta# irradiation, significant DNA repair occurred within 2 min. This fast repair could be inhibited by EDTA and pyrophosphate and probably reflected polynucleotide ligase activity. A slower component of DNA repair was detected between 15 and 60 min after irradiation, by which time most of the DNA had been repaired. In contrast, chromosome repair was not detectable until 45 min after irradiation, and nearly half of the chromatid breaks were repaired by 60 min. Cycloheximide, an inhibitor of protein synthesis, prevented chromosome break repair, yet had no effect on the immediate formation of chromatid exchanges or DNA repair. These results suggest the following: (1) the rapidly repairing DNA lesions are not important in the repair of chromosomes; (2) chromosome damage involves only a minority of the DNA lesions measured by alkaline and neutral DNA elution; and (3) chromosome repair may involve more than simply the repair of damaged DNA that can be detected by the alkaline and neutral elution assays

  20. Fast-turnaround alkyl nitrate measurements during the PROPHET 1998 summer intensive

    Science.gov (United States)

    Ostling, Kristi; Kelly, Brendan; Bird, Stephen; Bertman, Steven; Pippin, Margaret; Thornberry, Troy; Carroll, Mary Anne

    2001-10-01

    An automated gas chromatographic system for making fast-turnaround measurements of alkyl nitrates was developed and tested. Every 30 min, samples were automatically acquired on a 1/16-inch OD Tenax trap made from fused silica-lined stainless steel tubing and injected by thermal desorption into the gas chromatograph. The system exhibited good chromatographic resolution, minimal breakthrough, and on-trap stability for C3-C5 nitrates. The detection limit of the instrument was Biological Station in northern Michigan during the summer of 1998 from July 15 to August 22. Ambient results show a significant dynamic range with absolute levels affected by air mass history and pollution sources. The sum of measured C3-C5 alkyl nitrates obtained during this intensive ranged from 3.45 to 65.8 pptv, with a mean of 18.6 pptv and contributed 1% on average to total NOy, with a range of 0.5% to 3%. Differences in the contribution to NOy are found when the data are filtered according to air mass origin. A positive relationship between n-propyl nitrate and peroxypropionyl nitrate was observed over the course of the intensive.

  1. QUANTITATION OF INTRACELLULAR NAD(P)H IN LIVING CELLS CAN MONITOR AN IMBALANCE OF DNA SINGLE STRAND BREAK REPAIR IN REAL TIME

    Science.gov (United States)

    Quantitation of intracellular NAD(P)H in living cells can monitor an imbalance of DNA single strand break repair in real time.ABSTRACTDNA single strand breaks (SSBs) are one of the most frequent DNA lesions in genomic DNA generated either by oxidative stress or du...

  2. Phenomenology of an inducible mutagenic DNA repair pathway in Escherichia coli: SOS repair hypothesis

    International Nuclear Information System (INIS)

    Radman, M.

    1974-01-01

    A hypothesis is proposed according to which E. coli possesses an inducible DNA repair system. This hypothetical repair, which we call SOS repair, is manifested only following damage to DNA, and requires de novo protein synthesis. SOS repair in E. coli requires some known genetic elements: recA + , lex + and probably zab + . Mutagenesis by ultraviolet light is observed only under conditions of functional SOS repair: we therefore suspect that this is a mutation-prone repair. A number of phenomena and experiments is reviewed which at this point can best be interpreted in terms of an inducible mutagenic DNA repair system. Two recently discovered phenomena support the proposed hypothesis: existence of a mutant (tif) which, after a shift to elevated temperature, mimicks the effect of uv irradiation in regard to repair of phage lambda and uv mutagenesis, apparent activation of SOS repair by introduction into the recipient cell of damaged plasmid or Hfr DNA. Several specific predictions based on SOS repair hypothesis are presented in order to stimulate further experimental tests. (U.S.)

  3. An optimal replacement policy for a repairable system based on its repairman having vacations

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Li [School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092 (China); Xu Jian, E-mail: xujian@tongji.edu.c [School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092 (China)

    2011-07-15

    This paper studies a cold standby repairable system with two different components and one repairman who can take multiple vacations. If there is a component which fails and the repairman is on vacation, the failed component will wait for repair until the repairman is available. In the system, assume that component 1 has priority in use. After repair, component 1 follows a geometric process repair, while component 2 can be repaired as good as new after failures. Under these assumptions, a replacement policy N based on the failed times of component 1 is studied. The system will be replaced if the failure times of component 1 reach N. The explicit expression of the expected cost rate is given, so that the optimal replacement time N{sup *} is determined. Finally, a numerical example is given to illustrate the theoretical results of the model.

  4. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair

    Science.gov (United States)

    Park, Han Ki

    2013-01-01

    Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF. PMID:23807889

  5. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair.

    Science.gov (United States)

    Yoo, Byung Won; Park, Han Ki

    2013-06-01

    Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

  6. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair

    Directory of Open Access Journals (Sweden)

    Byung Won Yoo

    2013-06-01

    Full Text Available Repair of tetralogy of Fallot (TOF has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS and free pulmonary regurgitation (PR at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

  7. X-ray repair cross complementing protein 1 in base excision repair

    DEFF Research Database (Denmark)

    Hanssen-Bauer, Audun; Solvang-Garten, Karin; Akbari, Mansour

    2012-01-01

    X-ray Repair Cross Complementing protein 1 (XRCC1) acts as a scaffolding protein in the converging base excision repair (BER) and single strand break repair (SSBR) pathways. XRCC1 also interacts with itself and rapidly accumulates at sites of DNA damage. XRCC1 can thus mediate the assembly of large...

  8. Additive Manufacturing in Offsite Repair of Consumer Electronics

    Science.gov (United States)

    Chekurov, Sergei; Salmi, Mika

    Spare parts for products that are at the end of their life cycles, but still under warranty, are logistically difficult because they are commonly not stored in the central warehouse. These uncommon spare parts occupy valuable space in smaller inventories and take a long time to be transported to the point of need, thus delaying the repair process. This paper proposes that storing the spare parts on a server and producing them with additive manufacturing (AM) on demand can shorten the repair cycle by simplifying the logistics. Introducing AM in the repair supply chain lowers the number of products that need to be reimbursed to the customer due to lengthy repairs, improves the repair statistics of the repair shops, and reduces the number of items that are held in stock. For this paper, the functionality of the concept was verified by reverse engineering a memory cover of a portable computer and laser sintering it from polyamide 12. The additively manufactured component fit well and the computer operated normally after the replacement. The current spare part supply chain model and models with AM machinery located at the repair shop, the centralized spare part provider, and the original equipment manufacturer were provided. The durations of the repair process in the models were compared by simulating two scenarios with the Monte Carlo method. As the biggest improvement, the model with the AM machine in the repair shop reduced the duration of the repair process from 14 days to three days. The result points to the conclusion that placing the machine as close to the need as possible is the best option, if there is enough demand. The spare parts currently compatible with AM are plastic components without strict surface roughness requirements, but more spare parts will become compatible with the development of AM.

  9. Repair systems with exchangeable items and the longest queue mechanism

    NARCIS (Netherlands)

    Ravid, R.; Boxma, O.J.; Perry, D.

    2013-01-01

    We consider a repair facility consisting of one repairman and two arrival streams of failed items, from bases 1 and 2. The arrival processes are independent Poisson processes, and the repair times are independent and identically exponentially distributed. The item types are exchangeable, and a

  10. Repair systems with exchangeable items and the longest queue mechanism

    NARCIS (Netherlands)

    Ravid, R.; Boxma, O.J.; Perry, D.

    2011-01-01

    We consider a repair facility consisting of one repairman and two arrival streams of failed items, from bases 1 and 2. The arrival processes are independent Poisson processes, and the repair times are independent and identically exponentially distributed. The item types are exchangeable, and a

  11. A bivariate optimal replacement policy for a multistate repairable system

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Yam, Richard C.M.; Zuo, Ming J.

    2007-01-01

    In this paper, a deteriorating simple repairable system with k+1 states, including k failure states and one working state, is studied. It is assumed that the system after repair is not 'as good as new' and the deterioration of the system is stochastic. We consider a bivariate replacement policy, denoted by (T,N), in which the system is replaced when its working age has reached T or the number of failures it has experienced has reached N, whichever occurs first. The objective is to determine the optimal replacement policy (T,N)* such that the long-run expected profit per unit time is maximized. The explicit expression of the long-run expected profit per unit time is derived and the corresponding optimal replacement policy can be determined analytically or numerically. We prove that the optimal policy (T,N)* is better than the optimal policy N* for a multistate simple repairable system. We also show that a general monotone process model for a multistate simple repairable system is equivalent to a geometric process model for a two-state simple repairable system in the sense that they have the same structure for the long-run expected profit (or cost) per unit time and the same optimal policy. Finally, a numerical example is given to illustrate the theoretical results

  12. Bayesian Framework based Damage Segmentation (BFDS) with Time-Reversal Tomography (TRT) for Damage Characterization in Complex Aircraft Structures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To meet the NASA's need for innovative technologies that decrease turn-around time for inspections and assessments for safe operations of aircraft and spacecraft,...

  13. Smoking increases the risk of early meniscus repair failure.

    Science.gov (United States)

    Blackwell, Ryan; Schmitt, Laura C; Flanigan, David C; Magnussen, Robert A

    2016-05-01

    The goal of this study is to determine whether patients who smoke cigarettes at the time of surgery are at significantly increased risk of early meniscus repair failure relative to non-smokers. Retrospective chart review identified 64 current smokers within a series of 444 consecutive patients who underwent meniscus repair during a 7 years period. Fifty-two of these 64 smokers were available for follow-up and were matched by age, sex, and ACL status with non-smokers from the same cohort. Records of these 104 patients with a total of 120 meniscus repairs were reviewed to identify meniscus repair failure (defined as repeat surgery on the index meniscus) during the median 13-month (range: 3-79 months) follow-up period. The smoking and non-smoking groups were similar in age, sex, ACL status, BMI, meniscus repair technique, and meniscus involved. Meniscus repair failure occurred in 19 of the 112 menisci in 104 patients, for an overall failure risk of 17 %. Of the 19 failures, 14 occurred in 79 repaired medial menisci (18 % failure risk) and 5 occurred in 33 repaired lateral menisci (15 % failure risk). Meniscus repair failure occurred in significantly more smokers (15 failures in 56 menisci in 52 patients -27 % failure risk) than non-smokers (4 failures in 56 menisci in 52 patients -7 % failure risk) (p = 0.0076). Smoking is associated with significantly increased risk of early meniscus repair failure as defined by the incidence of repeat surgery on the index meniscus. III.

  14. Learning curve analysis of mitral valve repair using telemanipulative technology.

    Science.gov (United States)

    Charland, Patrick J; Robbins, Tom; Rodriguez, Evilio; Nifong, Wiley L; Chitwood, Randolph W

    2011-08-01

    To determine if the time required to perform mitral valve repairs using telemanipulation technology decreases with experience and how that decrease is influenced by patient and procedure variables. A single-center retrospective review was conducted using perioperative and outcomes data collected contemporaneously on 458 mitral valve repair surgeries using telemanipulative technology. A regression model was constructed to assess learning with this technology and predict total robot time using multiple predictive variables. Statistical analysis was used to determine if models were significantly useful, to rule out correlation between predictor variables, and to identify terms that did not contribute to the prediction of total robot time. We found a statistically significant learning curve (P learning percentage∗ derived from total robot times† for the first 458 recorded cases of mitral valve repair using telemanipulative technology is 95% (R(2) = .40). More than one third of the variability in total robot time can be explained through our model using the following variables: type of repair (chordal procedures, ablations, and leaflet resections), band size, use of clips alone in band implantation, and the presence of a fellow at bedside (P Learning in mitral valve repair surgery using telemanipulative technology occurs at the East Carolina Heart Institute according to a logarithmic curve, with a learning percentage of 95%. From our regression output, we can make an approximate prediction of total robot time using an additive model. These metrics can be used by programs for benchmarking to manage the implementation of this new technology, as well as for capacity planning, scheduling, and capital budget analysis. Copyright © 2011 The American Association for Thoracic Surgery. All rights reserved.

  15. 40 CFR 798.5500 - Differential growth inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA...

    Science.gov (United States)

    2010-07-01

    ... repair proficient and repair deficient bacteria: âBacterial DNA damage or repair tests.â 798.5500 Section... inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA damage or repair tests.” (a... killing or growth inhibition of repair deficient bacteria in a set of repair proficient and deficient...

  16. Semi-Automated Diagnosis, Repair, and Rework of Spacecraft Electronics

    Science.gov (United States)

    Struk, Peter M.; Oeftering, Richard C.; Easton, John W.; Anderson, Eric E.

    2008-01-01

    capacity and skill demands from exceeding crew time and training limits, the CLEAR project is examining options provided by non-real time tele-operations, robotics, and a new generation of diagnostic equipment. This paper outlines a strategy to create an effective repair environment where, with the support of ground based engineers, crewmembers can diagnose, repair and test flight electronics in-situ. This paper also discusses the implications of successful tele-robotic repairs when expanded to rework and reconfiguration of used flight assets for building Constellation infrastructure elements.

  17. A successful double-layer facial nerve repair: A case presentation

    Directory of Open Access Journals (Sweden)

    Mehmet Dadaci

    2015-04-01

    Full Text Available The best method to repair the facial nerve is to perform the primary repair soon after the injury, without any tension in the nerve ends. We present a case of patient who had a full-thickness facial nerve cut at two different levels. The patient underwent primary repair, recovered almost completely in the fourth postoperative month, and had full movement in mimic muscles. Despite lower success rates in double-level cuts, performing appropriate primary repair at an appropriate time can reverse functional losses at early stages, and lead to recovery without any complications. [Hand Microsurg 2015; 4(1.000: 24-27

  18. Repair of damaged DNA in vivo: Final technical report

    International Nuclear Information System (INIS)

    Hanawalt, P.C.

    1987-09-01

    This contract was initiated in 1962 with the US Atomic Energy Commission to carry out basic research on the effects of radiation on the process of DNA replication in bacteria. Within the first contract year we discovered repair replication at the same time that Setlow and Carrier discovered pyrimidine dimer excision. These discoveries led to the elucidation of the process of excision-repair, one of the most important mechanisms by which living systems, including humans, respond to structural damage in their genetic material. We improved methodology for distinguishing repair replication from semiconservative replication and instructed others in these techniques. Painter then was the first to demonstrate repair replication in ultraviolet irradiated human cells. He, in turn, instructed James Cleaver who discovered that skin fibroblasts from patients with xeroderma pigmentosum were defective in excision-repair. People with this genetic defect are extremely sensitive to sunlight and they develop carcinomas and melanomas of the skin with high frequency. The existence of this hereditary disease attests to the importance of DNA repair in man. We certainly could not survive in the normal ultraviolet flux from the sun if our DNA were not continuously monitored for damage and repaired. Other hereditary diseases such as ataxia telangiectasia, Cockayne's syndrome, Blooms syndrome and Fanconi's anemia also involve deficiencies in DNA damage processing. The field of DNA repair has developed rapidly as we have learned that most environmental chemical carcinogens as well as radiation produce repairable damage in DNA. 251 refs

  19. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  20. Nuclear-piping-repair planning today needs skill, organization

    International Nuclear Information System (INIS)

    O'Keefe, W.

    1986-01-01

    Nuclear power plant piping continues to experience failures and imminent threat of failure, despite a high level of care in design, analysis, fabrication, or installation. Continual inspection and surveillance and letter-by-letter following of procedures are not completely effective remedies, either. Both short-time-frame accidents and slowly progressing insidious complaints have caused loss of capacity, availability, and even confidence that the unit will work at close-to-expected performance. The fixes for nuclear-piping complaints cover a wide span, from mere carrying out of well-known repair procedures on either small scale or large, all the way to highly engineered solutions to a problem, with months of study and analysis followed by weighing of alternative methods. With some of the problems, little special planning is necessary. The repair is understood, and the time it needs is well within the envelope of a scheduled outage. Radiation exposure of personnel will not exceed expected moderate limits. And if the repair is a repeat performance of a recent similar one, little can go wrong. The planning for many other repairs, however, is so essential that even a minor failing in it will bring a debacle, with over-run, losses in revenue, and senseless expenditure of man-rems. Look at two types of planning for nuclear piping repair, as revealed at a recent American Welding Society conference on maintenance welding in nuclear power plants

  1. DNA repair in human cells

    International Nuclear Information System (INIS)

    Regan, J.D.; Carrier, W.L.; Kusano, I.; Furuno-Fukushi, I.; Dunn, W.C. Jr.; Francis, A.A.; Lee, W.H.

    1982-01-01

    Our primary objective is to elucidate the molecular events in human cells when cellular macromolecules such as DNA are damaged by radiation or chemical agents. We study and characterize (i) the sequence of DNA repair events, (ii) the various modalities of repair, (iii) the genetic inhibition of repair due to mutation, (iv) the physiological inhibition of repair due to mutation, (v) the physiological inhibition of repair due to biochemical inhibitors, and (vi) the genetic basis of repair. Our ultimate goals are to (i) isolate and analyze the repair component of the mutagenic and/or carcinogenic event in human cells, and (ii) elucidate the magnitude and significance of this repair component as it impinges on the practical problems of human irradiation or exposure to actual or potential chemical mutagens and carcinogens. The significance of these studies lies in (i) the ubiquitousness of repair (most organisms, including man, have several complex repair systems), (ii) the belief that mutagenic and carcinogenic events may arise only from residual (nonrepaired) lesions or that error-prone repair systems may be the major induction mechanisms of the mutagenic or carcinogenic event, and (iii) the clear association of repair defects and highly carcinogenic disease states in man [xeroderma pigmentosum (XP)

  2. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

    LENUS (Irish Health Repository)

    Joyce, C W

    2014-01-01

    We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force was required to create a 2 mm gap in the four-strand repair method compared with the knotless barbed technique. There was a significant reduction in the cross-sectional area in the barbed suture group after repair compared with the Adelaide group. This would create better gliding within the pulley system in vivo and could decrease gapping and tendon rupture.

  3. Development of management system for plant repairing work

    International Nuclear Information System (INIS)

    Terauchi, Makoto

    1999-01-01

    In the fast breeder reactor, ''Monju'', in order to conduct nuclear plant repairing works securely and effectively, development of a computer system to assist management business on plant repairing work was begun on 1993. The system has been applied to about 5,000 times of operational management through past four times of plant inspection and to daily inspections and maintenance, and is daily used at working places of ''Monju'' such as issue/management of about 110,000 times of operational prohibition tag in isolated management. And, by automation of issue/management on working sheets and operational prohibition tag and others conducted hitherto by hand, the management business has been largely rationalized. (G.K.)

  4. The applicability of the Centeno, Chaudhary and Lopez repair time standard methodology in a rail maintenance environment

    Directory of Open Access Journals (Sweden)

    Rommelspacher, Karl Otto

    2015-11-01

    Full Text Available The establishment of labour standards within a production environment has become common practice, and is receiving growing recognition in the maintenance environment. However, the application of labour standards in a transit maintenance organisation has received limited attention. Centeno, Chaudhary and Lopez have developed a repair time standard methodology that has been applied in the transit bus maintenance facilities of three agencies in central Florida in the USA. An investigation into the applicability of this methodology in a rail maintenance environment in South Africa forms the basis for this study.

  5. Predictable repair of provisional restorations.

    Science.gov (United States)

    Hammond, Barry D; Cooper, Jeril R; Lazarchik, David A

    2009-01-01

    The importance of provisional restorations is often downplayed, as they are thought of by some as only "temporaries." As a result, a less-than-ideal provisional is sometimes fabricated, in part because of the additional chair time required to make provisional modifications when using traditional techniques. Additionally, in many dental practices, these provisional restorations are often fabricated by auxillary personnel who may not be as well trained in the fabrication process. Because provisionals play an important role in achieving the desired final functional and esthetic result, a high-quality provisional restoration is essential to fabricating a successful definitive restoration. This article describes a method for efficiently and predictably repairing both methacrylate and bis-acryl provisional restorations using flowable composite resin. By use of this relatively simple technique, provisional restorations can now be modified or repaired in a timely and productive manner to yield an exceptional result. Successful execution of esthetic and restorative dentistry requires attention to detail in every aspect of the case. Fabrication of high-quality provisional restorations can, at times, be challenging and time consuming. The techniques for optimizing resin provisional restorations as described in this paper are pragmatic and will enhance the delivery of dental treatment.

  6. Science and animal models of marrow stimulation for cartilage repair.

    Science.gov (United States)

    Fortier, Lisa A; Cole, Brian J; McIlwraith, C Wayne

    2012-03-01

    Microfracture of subchondral bone to enhance cartilage repair is a popular surgical technique used in human and animal patients. Clinical results with resolution or improvement in pain are promising and last on average for 2 to 3 years. Animal studies aimed at understanding microfracture indicate that the repair tissue continues to remodel toward chondrogenesis for at least a year, but longer term results are not available to gain insight into the mechanism of microfracture function or failure over time. Subchondral bone sclerosis and central lesional osteophyte formation following subchondral bone microfracture have been observed in animal models of microfracture, but studies do not provide any insight into the etiology of these pathologies. The continued maturation of microfracture repair tissue over time supports further investigation of microfracture or microfracture-augmented cartilage repair procedures with caution for the investigator and clinician to be observant for conditions that lead to subchondral bone sclerosis or central osteophyte formation, and what affect these boney reactions have on clinical outcome.

  7. Is laparoscopic inguinal hernia repair more effective than open repair

    International Nuclear Information System (INIS)

    Aly, O.; Green, A.; Joy, M.; Wong, C.H.; Malik, M

    2011-01-01

    To systematically review randomized controlled trials, (RCT) evidence comparing Lichtenstein to total extraperitoneal (TEP) hernia repair in terms of clinical and cost effectiveness. Study Design: Case series. Place and Duration of Study: The study was conducted at University of Abderdeen, U.K. Methodology: A comprehensive online literature search was undertaken using databases such as MEDLINE, PubMed, EMBASE and Springerlink. Studies were then short listed according to the selection criteria (RCT with over 100 subject and English language publications from 1995 onwards) and appraised using the SIGN Methodology Checklist. A meta analysis of the data was also performed using RevMan software. Results: Analysis of reported data shows that TEP has less postoperative pain and return to work than Lichtenstein method. Operation time is shown to be longer in the TEP but this difference is shortened with increasing surgeon experience. The meta-analysis of the data on complications shows that there are no significant differences between the two types of procedures. TEP causes more short-term recurrences which are attributed to the learning curve effect. Long term recurrence rates on the other hand show no significant differences. At present TEP is slightly more expensive than Lichtenstein repair. Conclusion: Both TEP and Lichtenstein repair are clinically effective procedures. The choice between them should be made on a case-by-case basis; which depends on the patient's preference and characteristics such as age, work and health status. (author)

  8. Implementing optical fibres for the structural health monitoring of composite patch repaired structures

    DEFF Research Database (Denmark)

    Karatzas, Vasileios; Kotsidis, Elias A.; Tsouvalis, Nicholas G.

    2017-01-01

    Structural health monitoring is increasingly being implemented to improve the level of safety of structures and to reduce inspection and repair costs by allowing for correct planning of these actions, if needed. Composite patch repairing presents an appealing alternative to traditional repair...... methods as it enables the reduction of closedown time and the mitigation of complications associated with traditional repair methods. As reinforcement with the use of composite patches is predominantly performed at defected structures, the urge to monitor the performance of the repair becomes even greater...

  9. The incidence of symptomatic malrotation post gastroschisis repair.

    LENUS (Irish Health Repository)

    Abdelhafeez, A

    2011-12-01

    Gastroschisis is known to be associated with abnormal bowel rotation. Currently, the broadly accepted practice is not to perform Ladd\\'s procedure routinely at the time of closure of gastroschisis defects. However the incidence of symptomatic malrotation and volvulus post gastroschisis repair is unknown; this incidence is important in view of the current practice of bedside gastroschisis closure. This study examined the incidence of symptomatic malrotation and volvulus following gastroschisis repair.

  10. Critical period and risk factors for retear following arthroscopic repair of the rotator cuff

    NARCIS (Netherlands)

    Barth, J.; Andrieu, K.; Fotiadis, E.; Hannink, G.J.; Barthelemy, R.; Saffarini, M.

    2017-01-01

    PURPOSE: The incidence of retear following rotator cuff repair remains a major concern, and the cause and timing of retear remain unclear. The aim of this study was to prospectively investigate the timing of retears following rotator cuff repair at multiple time intervals. The hypothesis was that

  11. Evidence for three types of x-ray damage repair in yeast and sensitivity of totally repair deficient strains to sunlight

    International Nuclear Information System (INIS)

    Game, J.C.; Schild, D.; Mortimer, R.K.

    1987-01-01

    Mutants of yeast that confer sensitivity to x-rays are known to fall into two epistasis groups, called here the RAD51 and RAD18 groups, which are each thought to control a different type of x-ray repair. They examine here the role of genes in a third repair pathways in x-ray repair. RAD1 and RAD3 are known to be important in the repair of pyrimidine dimers after uv-irradiation. They find that these genes can also play an important role in x-ray repair, but that this role is only exposed when both the other pathways of x-ray repair are blocked. Double mutants blocked in the RAD51 and RAD18 pathways are significantly less x-ray sensitive than triple mutants blocked in these pathways but also mutant in either the RAD1 or RAD3 genes. In a related experiment, they tested the importance of DNA repair in nature by determining the sensitivity to natural unfiltered sunlight of a strain lacking all known DNA repair pathways. They constructed a quadruple mutant strain containing RAD1-1, RAD18-2, RAD51-1 and PHR1-1. The latter mutation blocks the cell's ability to photoreactivate uv damage. They found that this strain was so sensitive to sunlight that less than three seconds' exposure would cause an average of one lethal hit per cell, and survival was less than 2% after ten seconds' exposure. Wild type yeast at sea level showed no killing after thirty minutes. the quadruple mutant is approximately one thousand times more sensitive to sunlight than the related wild type

  12. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  13. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.

    Science.gov (United States)

    Maddox, Grady E; Ludwig, Jonathan; Craig, Eric R; Woods, David; Joiner, Aaron; Chaudhari, Nilesh; Killingsworth, Cheryl; Siegal, Gene P; Eberhardt, Alan; Ponce, Brent

    2015-05-01

    To compare and analyze biomechanical properties and histological characteristics of flexor tendons either repaired by a 4-strand modified Kessler technique or using barbed suture with a knotless repair technique in an in vivo model. A total of 25 chickens underwent surgical transection of the flexor digitorum profundus tendon followed by either a 4-strand Kessler repair or a knotless repair with barbed suture. Chickens were randomly assigned to 1 of 3 groups with various postoperative times to death. Harvested tendons were subjected to biomechanical testing or histologic analysis. Harvested tendons revealed failures in 25% of knotless repairs (8 of 32) and 8% of 4-strand Kessler repairs (2 of 24). Biomechanical testing revealed no significant difference in tensile strength between 4-strand Kessler and barbed repairs; however, this lack of difference may be attributed to lower statistical power. We noted a trend toward a gradual decrease in strength over time for barbed repairs, whereas we noticed the opposite for the 4-strand Kessler repairs. Mode of failure during testing differed between repair types. The barbed repairs tended toward suture breakage as opposed to 4-strand Kessler repairs, which demonstrated suture pullout. Histological analysis identified no difference in the degree of inflammation or fibrosis; however, there was a vigorous foreign body reaction around the 4-strand Kessler repair and no such response around the barbed repairs. In this model, knotless barbed repairs trended toward higher in vivo failure rates and biomechanical inferiority under physiologic conditions, with each repair technique differing in mode of failure and respective histologic reaction. We are unable to recommend the use of knotless barbed repair over the 4-strand modified Kessler technique. For the repair techniques tested, surgeons should prefer standard Kessler repairs over the described knotless technique with barbed suture. Copyright © 2015 American Society for Surgery

  14. VARIANT FOR CONSTRUCTION, REPAIR OR RECONSTRUCTION OF BUILDING

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2016-01-01

    Full Text Available In the XXI century moral depreciation concept comprises not only deterioration of outside appearance of construction elements in the course of time but accelerated fashion changes in respect of interior design and rapid increase in technical level for residence buildings. For this reason if average rate of building dilapidation in the buildings of series 1–335, 1–335А and 1–464А constructed in Minsk within the period of 1957–1975 and being operated till 2005–2006 has constituted 25–29 % and their moral depreciation has been equal to more than 40 % then rate of the moral depreciation has significantly increased in the XXI century. Such situation requires execution of special investigations. High operating rates of refinancing have led to the necessity for record keeping of initial expenses and repairability levels because selection of building construction, repair or reconstruction variant depends on these parameters. Repairability classification of main elements of residence buildings and premises has been proposed for regulation of such selection procedure. In this case it is recommended to take into account technological effectiveness of repair and technical service, verifiability, accessibility, easy dismountability, substitutability and interchangeability of construction elements and technical devices. The paper presents nomograms that permit to make easier practical calculations on determination of cost-efficient time period for operation of the element prior to its substitution at various refinancing rates and also for comparison of relative initial expenses according to time service. 

  15. Space-Efficient Re-Pair Compression

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Prezza, Nicola

    2017-01-01

    Re-Pair [5] is an effective grammar-based compression scheme achieving strong compression rates in practice. Let n, σ, and d be the text length, alphabet size, and dictionary size of the final grammar, respectively. In their original paper, the authors show how to compute the Re-Pair grammar...... in expected linear time and 5n + 4σ2 + 4d + √n words of working space on top of the text. In this work, we propose two algorithms improving on the space of their original solution. Our model assumes a memory word of [log2 n] bits and a re-writable input text composed by n such words. Our first algorithm runs...

  16. Regulation of DNA repair processes in mammalian cell

    International Nuclear Information System (INIS)

    Bil'din, V.N.; Sergina, T.B.; Zhestyanikov, V.D.

    1992-01-01

    A study was made of the repair of ionizing radiation-induced DNA single-strand breaks (SSB) in proliferating and quiescent mouse Swiss 3T6 cells and in those stimulated from the quiet status by epidermal growth factor in combination with insulin, in the presence of specific inhibitors of DNA polymerase α and β (aphidicolin) and DNA polymerase β (2', 3'-dideoxythjymidine-5'-triphosphate). The repair of DNA SSB induced by X-ray-irradiation (10 Gy) or by γ-ray irradiation (150 Gy) is more sensitive to aphidicolin and mitogen-simulated cells three times stronger than in proliferating cells. The influence of 2', 3'-dideoxythymidine-5'-triphosphate on the rate of DNA SSB repair in cells of all the three types does not differ. Thus, the decrease in DNA repair efficiency in quiescent cells is connected with a decrease in the activity of aphidicolin-sensitive DNA polymerase, apparently DNA polymerase α

  17. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  18. Primary repair of colon injuries: clinical study of nonselective approach.

    Science.gov (United States)

    Lazovic, Ranko G; Barisic, Goran I; Krivokapic, Zoran V

    2010-12-02

    This study was designed to determine the role of primary repair and to investigate the possibility of expanding indications for primary repair of colon injuries using nonselective approach. Two groups of patients were analyzed. Retrospective (RS) group included 30 patients managed by primary repair or two stage surgical procedure according to criteria published by Stone (S/F) and Flint (Fl). In this group 18 patients were managed by primary repair. Prospective (PR) group included 33 patients with primary repair as a first choice procedure. In this group, primary repair was performed in 30 cases. Groups were comparable regarding age, sex, and indexes of trauma severity. Time between injury and surgery was shorter in PR group, (1.3 vs. 3.1 hours). Stab wounds were more frequent in PR group (9:2), and iatrogenic lesions in RS group (6:2). Associated injuries were similar, as well as segmental distribution of colon injuries. S/F criteria and Flint grading were similar.In RS group 15 primary repairs were successful, while in two cases relaparotomy and colostomy was performed due to anastomotic leakage. One patient died. In PR group, 25 primary repairs were successful, with 2 immediate and 3 postoperative (7-10 days) deaths, with no evidence of anastomotic leakage. Results of this study justify more liberal use of primary repair in early management of colon injuries. Current Controlled Trials ISRCTN94682396.

  19. DNA-radiosensitivity and repair in mammolian cells

    International Nuclear Information System (INIS)

    Proskuryakov, S.Ya.; Ivannik, B.P.; Ryabchenko, N.I.

    1979-01-01

    Determination was made of the formation and repair of single-stranded DNA breaks (SB) in cells of rat thymus and liver and Ehrlich's ascites tumor (EAT) with the use of the method of low-gradient viscosimetry of alkaline cell lysates. The radiochemical yield of single-stranded breaks (Gsub(SB)) induced by irradiation of animals is 41.2 eV/break for hepatocytes, 96.8 eV/break, for thymocytes, and 129.7 eV/break, for EAT cells. The half-recovery time of single-stranded DNA breaks for cells of thymus and EAT exposed in vivo is 16.0 and 5.1 s -1 , correspondingly. In hepatocytes exposed in vivo and in vitro no repairs occurs for 3 h. Under conditions of inhibition of SB repair, when suspensions of thymocytes and hepatocytes were exposed in vitro at 4 deg C, Gsub(SB) is 35.5 and 38.7 eV/break, respectively. The analysis of the data obtained prompts the conclusion that under in vivo conditions, there is a correlation between DNA radiosensitivity and the rate of repair processes

  20. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    International Nuclear Information System (INIS)

    Gnannt, Ralph; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa; Stephens, Derek; Connolly, Bairbre

    2017-01-01

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  1. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    Energy Technology Data Exchange (ETDEWEB)

    Gnannt, Ralph, E-mail: ralph.gnannt@usz.ch; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada); Stephens, Derek [University of Toronto, Child Health Evaluative Sciences (Canada); Connolly, Bairbre [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada)

    2017-06-15

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  2. Functional Outcomes and Return to Sports After Acute Repair, Chronic Repair, and Allograft Reconstruction for Proximal Hamstring Ruptures.

    Science.gov (United States)

    Rust, David A; Giveans, M Russell; Stone, Rebecca M; Samuelson, Kathryn M; Larson, Christopher M

    2014-06-01

    There are limited data regarding outcomes and return to sports after surgery for acute versus chronic proximal hamstring ruptures. Surgery for chronic proximal hamstring ruptures leads to improved outcomes and return to sports but at a lower level than with acute repair. Proximal hamstring reconstruction with an Achilles allograft for chronic ruptures is successful when direct repair is not possible. Cohort study; Level of evidence, 3. Between 2002 and 2012, a total of 72 patients with a traumatic proximal hamstring rupture (51 acute, 21 chronic) underwent either direct tendon repair with suture anchors (n = 58) or Achilles allograft tendon reconstruction (n = 14). Results from the Single Assessment Numeric Evaluation (SANE) for activities of daily living (ADL) and sports-related activities, Short Form-12 (SF-12), visual analog scale (VAS), and a patient satisfaction questionnaire were obtained. The mean time to surgery in the chronic group was 441.4 days versus 17.8 days in the acute group. At a mean follow-up of 45 months, patients with chronic tears had inferior sports activity scores (70.2% vs 80.3%, respectively; P = .026) and a trend for decreased ADL scores (86.5% vs 93.3%, respectively; P = .085) compared with those with acute tears. Patients with chronic tears, however, reported significant improvements postoperatively for both sports activity scores (30.3% to 70.2%; P sports activity scores equal to those of chronic repair (P = .507 and P = .904, respectively). There were no significant differences between groups in SF-12, VAS, or patient satisfaction outcomes (mean, 85.2% satisfaction overall). Acute repair was superior to chronic surgery with regard to return to sports. Acute and chronic proximal hamstring repair and allograft reconstruction had favorable results for ADL. For low-demand patients or those with medical comorbidities, delayed repair or reconstruction might be considered with an expected 87% return to normal ADL. For patients who desire to

  3. Energy policy turnaround in distress. Why should the energy policy put on success certificates; Energiewende in Not. Warum die Energiepolitik auf Erfolgsnachweise setzen sollte

    Energy Technology Data Exchange (ETDEWEB)

    Hengstenberg, Johannes D. [Gemeinnuetzige Beratungsgesellschaft co2online mbH, Berlin (Germany); Wolff, Dieter [Ostfalia-Hochschule Wolfenbuettel (Germany). Inst. fuer Energieoptimierte Systeme - EOS

    2013-05-15

    In spite of all the promotional programs, regulations and laws, in spite of all activities of producers and suppliers with multi-million dollar advertising revenues, marketing revenues and training usually only half of the possible based on the predicted prognoses for the energy policy turnaround is achieved in practice. The authors of the contribution under consideration analyze the reasons for this and demonstrate methods of solution.

  4. Influence of repair length on residual stress in the repair weld of a clad plate

    International Nuclear Information System (INIS)

    Jiang Wenchun; Xu, X.P.; Gong, J.M.; Tu, S.T.

    2012-01-01

    Highlights: ► Residual stress in the repair weld of a stainless steel clad plate is investigated. ► The effect of repair length on residual stress has been studied. ► Large tensile residual stress is generated in the repair weld and heat affected zone. ► With the increase of repair length, transverse stress is decreased. ► Repair length has little effect on longitudinal stress. - Abstract: A 3-D sequential coupling finite element simulation is performed to investigate the temperature field and residual stress in the repair weld of a stainless steel clad plate. The effect of repair length on residual stress has been studied, aiming to provide a reference for repairing the cracked clad plate. The results show that large tensile residual stresses are generated in the repair weld and heat affected zone (HAZ), and then decrease gradually away from the weld and HAZ. The residual stresses through thickness in the clad layer are relative uniform, while they are non-uniform in the base metal. A discontinuous stress distribution is generated across the interface between weld metal and base metal. The repair length has a great effect on transverse stress. With the increase of repair length, the transverse stress is decreased. When the repair length is increased to 14 cm, the peak of transverse stress has been decreased below yield strength, and the transverse stress in the weld and HAZ has also been greatly decreased. But the repair length has little effect on longitudinal stress.

  5. Repair of walls of coke ovens with a volume of 41. 6 m/sup 3/

    Energy Technology Data Exchange (ETDEWEB)

    Pyatnitsa, V.A.; Bulyga, N.I.

    1988-11-01

    Discusses repair of coke oven walls and the heating system of a battery with coke ovens 7.0 m high in the Avdeevka plant. The following problems are evaluated: types of wall deformation and wear, distribution of wear zones, zones with maximum wear, coke oven repair without cooling and with cooling, repair of cracks in oven walls, effects of wall temperature (in schemes without cooling) on repair, behavior of walls in zones of temperature differences, sequence of repair operations, repair of heating channels, specific problems of wall repair at the machine side and at the pusher side of a coke oven battery, methods for reducing repair time, materials used for coke oven repair.

  6. One-Stage Cleft Lip and Palate Repair in an Older Population.

    Science.gov (United States)

    Guneren, Ethem; Canter, Halil Ibrahim; Yildiz, Kemalettin; Kayan, Resit Burak; Ozpur, Mustafa Aykut; Baygol, Emre Gonenc; Sagir, Haci Omer; Kuzu, Ismail Melih; Akman, Onur; Arslan, Serap

    2015-07-01

    In underdeveloped countries one-stage definitive repair of cleft lip and palate is considered for late-presenting patients. A total of 25 patients with unoperated cleft lip and palate more than 2 years of age were enrolled in this study for one-stage simultaneous repair of cleft lip and palate. According to Veau-Wardill-Kilner push-back technique, 2 flap palatoplasties were performed for palatal repairs; all of the lips were repaired with the Millard II rotation-advancement technique. The authors experienced no perioperative or postoperative life-threatening complications. With respect to the registered operation periods, longer times were required to perform these double operations, but this elongation is shorter than the sum of the periods if the 2 operations had been performed separately. Although the authors were unable to evaluate the late postoperative results because the authors could not follow-up the patients after they were discharged the day after surgery, the early results related to the success of the operation without any surgical complication were prone to meet the parents' and patients' expectations. The authors presented their experiences with many volunteer cleft lip and palate trips to third world countries; however the structure of this article is not a new hypothesis and data based to support a scientific study, but observations are objective to get a conclusion. To perform one-stage definitive repair of the cleft lip and palate in late-presented patients was the reality that they had only 1 chance to undergo these operations. According to the terms and conditions of this challenging operation, one-stage simultaneous repair of cleft lip and palate is a more demanding and time-consuming procedure than is isolated cleft lip repair or cleft palate repair. Although technically challenging, single-stage repair of the whole deformity in late-presenting patients is a feasible, reliable, successful, and safe procedure in authors' experience.

  7. Characteristics of Occupational Exposure to Benzene during Turnaround in the Petrochemical Industries.

    Science.gov (United States)

    Chung, Eun-Kyo; Shin, Jung-Ah; Lee, Byung-Kyu; Kwon, Jiwoon; Lee, Naroo; Chung, Kwang-Jae; Lee, Jong-Han; Lee, In-Seop; Kang, Seong-Kyu; Jang, Jae-Kil

    2010-09-01

    The level of benzene exposure in the petrochemical industry during regular operation has been well established, but not in turnaround (TA), where high exposure may occur. In this study, the characteristics of occupational exposure to benzene during TA in the petrochemical companies were investigated in order to determine the best management strategies and improve the working environment. This was accomplished by evaluating the exposure level for the workers working in environments where benzene was being produced or used as an ingredient during the unit process. From 2003 to 2008, a total of 705 workers in three petrochemical companies in Korea were studied. Long- and short-term (< 1 hr) samples were taken during TAs. TA was classified into three stages: shut-down, maintenance and start-up. All works were classified into 12 occupation categories. The long-term geometric mean (GM) benzene exposure level was 0.025 (5.82) ppm (0.005-42.120 ppm) and the short-term exposure concentration during TA was 0.020 (17.42) ppm (0.005-61.855 ppm). The proportions of TA samples exceeding the time-weighted average, occupational exposure level (TWA-OEL in Korea, 1 ppm) and the short-term exposure limit (STEL-OEL, 5 ppm) were 4.1% (20 samples of 488) and 6.0% (13 samples of 217), respectively. The results for the benzene exposure levels and the rates of exceeding the OEL were both statistically significant (p < 0.05). Among the 12 job categories of petrochemical workers, mechanical engineers, plumbers, welders, fieldman and scaffolding workers exhibited long-term samples that exceeded the OEL of benzene, and the rate of exceeding the OEL was statistically significant for the first two occupations (p < 0.05). These findings suggest that the periodic work environment must be assessed during non-routine works such as TA.

  8. Development of underwater YAG laser repair welding robots for tanks

    International Nuclear Information System (INIS)

    Miwa, Yasuhiro; Satoh, Syuichi; Ito, Kosuke; Kochi, Tsutomu; Kojima, Toshio; Ohwaki, Katsura; Morita, Ichiro

    1999-01-01

    A remote-controlled repair welding robot which uses YAG laser welding technology in underwater environment was developed. This is an underwater robot technology combined with a laser welding technology. This report will describe the structure and performance of this robot, and the welding test results. The repair welding robot consists of two parts. The one is driving equipment, and the other is welding unit. It can swim in the tank, move around the tank wall, and stay on the welding area. After that it starts YAG laser repair welding. The target of this technology is inner surface repair of some tanks made of austenitic stainless steel, for example RW (Radioactive Waste) tanks. A degradation by General Corrosion and so on might be occurred at inner surface of these tanks in BWR type nuclear power plants. If the damaged area is wide, repair welding works are done. Some workers go into the tank and set up scaffolding after full drainage. In many cases it spends too much time for draining water and repair welding preparation. If the repair welding works can be done in underwater environment, the outage period will be reduced. This is a great advantage. (author)

  9. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...... base lesions is base excision repair, and such repair is crucial for neurons given their high rates of oxygen metabolism. Mismatch repair corrects base mispairs generated during replication and evidence indicates that oxidative DNA damage can cause this pathway to expand trinucleotide repeats, thereby...

  10. Improvement of adhesion performance of mortar-repair interface with inducing crack path into repair

    Directory of Open Access Journals (Sweden)

    A. Satoh

    2015-10-01

    Full Text Available The most important performance for repair materials is adhesion to the substrate. The authors experimentally find out that high modulus fine aggregates in repair material enhance strength of it as well as the strength of the interface repaired with it, compared to the ordinary repair without fine aggregates. This paper elaborates the mechanisms for that with fractographic observation and FEM analysis based on the results of experiment. Also the authors discuss the ways for enhancing the strength and ductility of the repaired mortar

  11. Indentation Damage and Crack Repair in Human Enamel*

    Science.gov (United States)

    Rivera, C.; Arola, D.; Ossa, A.

    2013-01-01

    Tooth enamel is the hardest and most highly mineralized tissue in the human body. While there have been a number of studies aimed at understanding the hardness and crack growth resistance behavior of this tissue, no study has evaluated if cracks in this tissue undergo repair. In this investigation the crack repair characteristics of young human enamel were evaluated as a function of patient gender and as a function of the distance from the Dentin Enamel Junction (DEJ). Cracks were introduced via microindentation along the prism direction and evaluated as a function of time after the indentation. Microscopic observations indicated that the repair of cracks began immediately after crack initiation and reaches saturation after approximately 48 hours. During this process he crack length decreased up to 10% of the initial length, and the largest degree of reduction occurred in the deep enamel, nearest the DEJ. In addition, it was found that the degree of repair was significantly greater in the enamel of female patients. PMID:23541701

  12. Radiobiological significance of DNA repair

    International Nuclear Information System (INIS)

    Kuzin, A.M.

    1978-01-01

    A short outline is given on the history of the problem relating to the repair of radiation injuries, specifically its molecular mechanisms. The most urgent problems which currently confront the researchers are noted. This is a further study on the role of DNA repair in post-radiation recovery, search for ways to activate and suppress DNA repair, investigations into the activity balance of various repair enzymes as well as the problem of errors in the structure of repairing DNA. An important role is attached to the investigations of DNA repair in solving a number of practical problems

  13. The energy policy turnaround and the respective models. The prognostic ability of energy scenarios; Die Energiewende und ihre Modelle. Was uns Energieszenarien sagen koennen - und was nicht

    Energy Technology Data Exchange (ETDEWEB)

    Dieckhoff, Christian; Leuschner, Anna (eds.)

    2016-07-01

    The booklet on energy scenarios in the frame of the energy policy turnaround includes the following contributions: How many scenarios do we need? The justification of relevant possibilities using idealized models; the underestimation of the climatic change; the burden of the possible achievable; wrong conclusions in the argumentation with scenarios; epistemic meta-analysis.

  14. Arthroscopic repair of large U-shaped rotator cuff tears without margin convergence versus repair of crescent- or L-shaped tears.

    Science.gov (United States)

    Park, Jin-Young; Jung, Seok Won; Jeon, Seung-Hyub; Cho, Hyoung-Weon; Choi, Jin-Ho; Oh, Kyung-Soo

    2014-01-01

    For large-sized tears of the rotator cuff, data according to the tear shape have not yet been reported for repair methodology, configuration, and subsequent integrity. The retear rate after the repair of large mobile tears, such as crescent- or L-shaped tears, is believed to be lower compared with retear rates after the repair of large U-shaped tears that are accompanied by anterior or posterior leaves of the rotator cuff. Cohort study; Level of evidence, 3. Data were collected and analyzed from 95 consecutive patients with a large-sized rotator cuff tear who underwent arthroscopic suture-bridge repair. Patients were divided into 2 groups: those having crescent- or L-shaped tears (mobile tear group, 53 patients) and those having U-shaped tears (U-shaped tear group, 42 patients). The integrity of the repaired constructs was determined by ultrasonography at 4.5, 12, and 24 months. Moreover, clinical evaluations were performed by using the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and muscle strength at intervals of 3, 6, 12, and 24 months postoperatively. On ultrasonography at 4.5, 12, and 24 months, a retear was detected in 6, 2, and 1 patients in the mobile tear group and in 5, 2, and 1 patients in the U-shaped tear group, respectively. Significant differences in retear rates were not detected between the groups overall or at each time point. Moreover, clinical scores were similar between groups, except for the presence of a temporarily higher Constant score at 12 months in the mobile tear group. With regard to shoulder strength, between-group comparisons indicated no statistically significant difference, either in abduction or external rotation, except for the presence of temporarily higher external rotation strength at 3 months in the mobile tear group. Arthroscopic repair of large-sized rotator cuff tears yielded substantial improvements in shoulder function, regardless of tear retraction, during midterm follow-up. Moreover, the

  15. Reliability analysis of a repairable k-out-of-n system with some components being suspended when the system is down

    International Nuclear Information System (INIS)

    Li Xiaohu; Zuo, Ming J.; Yam, Richard C.M.

    2006-01-01

    A k-out-of-n system with independent exponential components is investigated. It is assumed that some working components are suspended as soon as the system is down, repair starts immediately when a component fails and repair times are independent and exponentially distributed. Formulas for various reliability indices of the system including mean time between failures, mean working time in a failure-repair cycle, and mean down time in a failure-repair cycle are derived

  16. Control options for communal energy turnaround by energy coordination centres. Investigation based on the Erzgebirge energy region; Steuerungsmoeglichkeiten der kommunalen Energiewende durch Energieleitstellen. Untersuchung anhand der Energieregion-Erzgebirge

    Energy Technology Data Exchange (ETDEWEB)

    Zuk, David

    2012-11-01

    The book investigates the role of energy coordination centres for communal energy turnaround. The investigations were carried out in the Erzgebirge energy region, which comprises 13 member communities. It was found that the influence of an energy coordination centre on a community is parallel to the community's awareness of the necessity of local energy turnaround measures. Energy control centres can sharpen this awareness of communities by outlining individual advantages of engagement with these issues and by making concrete suggestions for projects. Here, it becomes clear that communities will be more interested especially in bigger investment projects of an (external)financially strong investor. Most of the communities under investigation were in the range of 1,000 to 7,000 inhabitants; it must be assumed that in this case the opinions of the highest-ranked person of communal authority. This consideration should influence the scope of action of energy coordination centres. The example of a 'pioneering community' in the energy region showed that the consulting services of the energy coordination centre not only led to lower energy consumption (and, in consequence, lower energy expenses) on a medium-term basis but also helped to coordinate the activities of initiatives, e.g. initiatives promoting citizens-owned solar power stations. As the book shows, energy coordination centres take care of communities in general but are also actively supporting initiatives within the community and have a coordinating function when it comes to intercommunity projects. While energy coordination centres are not a 'heal-all' for implementation of the energy turnaround at community level or regional level, they must be viewed as a powerful instrument to achieve it. (orig.)

  17. Spectrocolorimetric evaluation of repaired articular cartilage after a microfracture

    Directory of Open Access Journals (Sweden)

    Dohi Yoshihiro

    2008-09-01

    Full Text Available Abstract Background In clinical practice, surgeons differentiate color changes in repaired cartilage compared with surrounding intact cartilage, but cannot quantify these color changes. Objective assessments are required. A spectrocolorimeter was used to evaluate whether intact and repaired cartilage can be quantified. Findings We investigated the use of a spectrocolorimeter and the application of two color models (L* a* b* colorimetric system and spectral reflectance distribution to describe and quantify articular cartilage. In this study, we measured the colors of intact and repaired cartilage after a microfracture. Histologically, the repaired cartilage was a mixture of fibrocartilage and hyaline cartilage. In the L* a* b* colorimetric system, the L* and a* values recovered to close to the values of intact cartilage, whereas the b* value decreased over time after the operation. Regarding the spectral reflectance distribution at 12 weeks after the operation, the repaired cartilage had a higher spectral reflectance ratio than intact cartilage between wavelengths of 400 to 470 nm. Conclusion This study reports the first results regarding the relationship between spectrocolorimetric evaluation and the histological findings of repair cartilage after a microfracture. Our findings demonstrate the ability of spectrocolorimetric measurement to judge the repair cartilage after treatment on the basis of objective data such as the L*, a* and b* values and the SRP as a coincidence index of the spectral reflectance curve.

  18. Factors impacting arthroscopic rotator cuff repair operational throughput time at an ambulatory care center

    Directory of Open Access Journals (Sweden)

    Emily J. Curry

    2018-03-01

    Full Text Available Identifying patient factors influencing operational throughput time is becoming more imperative due to an increasing focus on value and cost savings in healthcare. The primary objective of this study was to determine patient factors influencing throughput time for primary rotator cuff repairs. Demographic information, medical history and operative reports of 318 patients from one ambulatory care center were retrospectively reviewed. Operating room set up, incision to closure and recovery room time were collected from anesthesia records. Univariate analysis was performed for both continuous and categorical variables. A stepwise, multivariable regression analysis was performed to determine factors associated with operating room time (incision to closure and recovery room time. Of the 318 patients, the mean age was 54.4±10.0 and 197 (61% were male. Male patients had a significantly longer OR time than females (115.5 vs. 100.8 minutes; P<0.001. Furthermore, patients set up in the beach chair position had a significantly longer OR time than patients positioned lateral decubitus (115.8 vs. 89.6 mins, P<0.0001. Number of tendons involved, and inclusion of distal clavicle excision, biceps tenodesis and labral debridement also added significant OR time. Type and number of support staff present also significantly affected OR time. Recovery room time was significantly longer patients who had surgery in the beach chair position (+9.61 minutes and for those who had a cardiac-related medical comorbidity (+11.7 minutes. Our study found that patients positioned in a beach chair spent significantly more time in the operating and recovery rooms. While ease of set up has been a stated advantage ofbeach chair position, we found the perceived ease of set up does not result in more efficient OR throughput.

  19. Characteristics of repair following very low doses

    International Nuclear Information System (INIS)

    Braby, L.A.; Metting, N.F.; Nelson, J.M.

    1987-01-01

    The effects of ionizing radiation on living systems being with the physical processes of energy deposition and develop through many stages of chemical reaction and biological response. The modeling effort attempts to organize the available data and theories of all of these stages into self-consistent models that can be compared and tested. In some cases, important differences among models result in only small differences in cell survival within the ranges of dose and dose rate that are normally investigated. To overcome this limitation, new ways of irradiating cells at extremes of dose rate, or ways of evaluating the effects of very small doses, are developed. Mathematical modeling and cellular studies complement each other. It has recently been found that some mechanisms are not adequate to account for the interaction of dose and repair time as they affect the reproductive survival of plateau-phase Chinese hamster ovary (CHO) cells. Repair of radiation-induced cellular damage plays a central role in the survival of cells exposed to doses of 1 Gy or more. This repair is responsible for the dose rate, split-dose and delayed plating effect and can be evaluated. Because split-dose and dose-rate experiments involve repair during irradiation and delayed plating experiments involve repair after irradiation is completed, it was originally thought that different repair processes were involved. It is now clear that this is not necessarily the case. Appropriately designed models can account for observed effects at conventional doses (1 Gy or more) whether they assume all damage is lethal unless repaired or some damage is innocuous unless it interacts with additional damage. The fact that the survival following a plating delay is always less than the survival following immediate plating at low doses indicates that the damage produced is probably not potentially lethal

  20. Influence of LET on repair of DNA damages in Deinococcus radiodurans

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Y; Tanaka, A; Kikuchi, M; Shimizu, T; Watanabe, H [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Cao, J P; Taucher-Scholz, G

    1997-03-01

    Inactivation caused by heavy ions was studied in dry cells of radioresistant bacterium Deinococcus radiodurans. All survival curves were characterized by a large shoulder of the curves. No final slopes of the exponential part of survival curves for heavy ion irradiation were steeper than that for 2.0 MeV electron irradiation. The plots of RBE versus LET showed no obvious peaks, suggesting that this bacterium can repair not only DNA double strand breaks (DSBs) but also clustered damage in DNA which may be induced by heavy ions. The genomic DNA of D. radiodurans was cleaved into large fragments with restriction enzyme Not I after post-irradiation incubation and the fragments were separated using pulsed-field gel electrophoresis (PFGE). DSBs induction and rejoining process were analyzed by detection of the reappearance of ladder pattern of DNA fragments. The required repair time after heavy ions irradiation was longer than the repair time for electrons at the same dose of irradiation, however, the rate of repair enzyme induction was almost similar to each other between electrons and heavy ions, suggesting that the same repair system is likely to be used after both low and high LET irradiations. (author)

  1. Role of DNA damage repair capacity in radiation induced adaptive response

    International Nuclear Information System (INIS)

    Yuan Dexiao; Pan Yan; Zhao Meijia; Chen Honghong; Shao Cunlin

    2009-01-01

    This work was to explore γ-ray induced radioadaptive response (RAR) in Chinese hamster ovary(CHO) cell lines of different DNA damage repair capacities. CHO-9 cells and the two repair-deficient strains, EM-C11(DNA single strand break repair deficient) and XR-C1(DNA double strand break repair deficient), were irradiated with a priming dose of 0.08 Gy or 0.016 Gy. After 4 or 7 hours, they were irradiated again with a challenging dose of 1 Gy. The micronucleus induction and plating efficiency of the cells were assayed. Under 0.08 Gy priming dose and 4-h interval, just the CHO-9 cells showed RAR, while with the 7-h interval the CHO-9 and EM-C11 showed RAR, but XR-C1 did not. When the cells were pretreated with a lower priming dose of 0.016 Gy in a 4-h time interval, all the three cell lines showed RAR to subsequent 1 Gy irradiation. It can be concluded that RAR is not only related to the priming dose and time interval, but also has close dependence on the ability of DNA damage repair. (authors)

  2. Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

    Science.gov (United States)

    Pauly, Stephan; Gerhardt, Christian; Chen, Jianhai; Scheibel, Markus

    2010-12-01

    Several techniques for arthroscopic repair of rotator cuff defects have been introduced over the past years. Besides established techniques such as single-row repairs, new techniques such as double-row reconstructions have gained increasing interest. The present article therefore provides an overview of the currently available literature on both repair techniques with respect to several anatomical, biomechanical, clinical and structural endpoints. Systematic literature review of biomechanical, clinical and radiographic studies investigating or comparing single- and double-row techniques. These results were evaluated and compared to provide an overview on benefits and drawbacks of the respective repair type. Reconstructions of the tendon-to-bone unit for full-thickness tears in either single- or double-row technique differ with respect to several endpoints. Double-row repair techniques provide more anatomical reconstructions of the footprint and superior initial biomechanical characteristics when compared to single-row repair. With regard to clinical results, no significant differences were found while radiological data suggest a better structural tendon integrity following double-row fixation. Presently published clinical studies cannot emphasize a clearly superior technique at this time. Available biomechanical studies are in favour of double-row repair. Radiographic studies suggest a beneficial effect of double-row reconstruction on structural integrity of the reattached tendon or reduced recurrent defect rates, respectively.

  3. Posterior Tracheopexy for Severe Tracheomalacia Associated with Esophageal Atresia (EA: Primary Treatment at the Time of Initial EA Repair versus Secondary Treatment

    Directory of Open Access Journals (Sweden)

    Hester F. Shieh

    2018-01-01

    Full Text Available PurposeWe review outcomes of posterior tracheopexy for tracheomalacia in esophageal atresia (EA patients, comparing primary treatment at the time of initial EA repair versus secondary treatment.MethodsAll EA patients who underwent posterior tracheopexy from October 2012 to September 2016 were retrospectively reviewed. Clinical symptoms, tracheomalacia scores, and persistent airway intrusion were collected. Indication for posterior tracheopexy was the presence of clinical symptoms, in combination with severe tracheomalacia as identified on bronchoscopic evaluation, typically defined as coaptation in one or more regions of the trachea. Secondary cases were usually those with chronic respiratory symptoms who underwent bronchoscopic evaluation, whereas primary cases were those found to have severe tracheomalacia on routine preoperative dynamic tracheobronchoscopy at the time of initial EA repair.ResultsA total of 118 patients underwent posterior tracheopexy: 18 (15% primary versus 100 (85% secondary cases. Median (interquartile range age was 2 months (1–4 months for primary (22% type C and 18 months (8–40 months for secondary (87% type C cases (p < 0.001. There were statistically significant improvements in most clinical symptoms postoperatively for primary and secondary cases, with no significant differences in any postoperative symptoms between the two groups (p > 0.1. Total tracheomalacia scores improved significantly in primary (p = 0.013 and secondary (p < 0.001 cases. Multivariable Cox regression analysis indicated no differences in persistent airway intrusion requiring reoperation between primary and secondary tracheopexy adjusting for imbalances in age and EA type (p = 0.67.ConclusionPosterior tracheopexy is effective in treating severe tracheomalacia with significant improvements in clinical symptoms and degree of airway collapse on bronchoscopy. With no significant differences in outcomes between primary and

  4. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.

    Science.gov (United States)

    Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M

    2015-10-01

    Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered

  5. Primary repair of colon injuries: clinical study of nonselective approach

    Directory of Open Access Journals (Sweden)

    Krivokapic Zoran V

    2010-12-01

    Full Text Available Abstract Background This study was designed to determine the role of primary repair and to investigate the possibility of expanding indications for primary repair of colon injuries using nonselective approach. Methods Two groups of patients were analyzed. Retrospective (RS group included 30 patients managed by primary repair or two stage surgical procedure according to criteria published by Stone (S/F and Flint (Fl. In this group 18 patients were managed by primary repair. Prospective (PR group included 33 patients with primary repair as a first choice procedure. In this group, primary repair was performed in 30 cases. Results Groups were comparable regarding age, sex, and indexes of trauma severity. Time between injury and surgery was shorter in PR group, (1.3 vs. 3.1 hours. Stab wounds were more frequent in PR group (9:2, and iatrogenic lesions in RS group (6:2. Associated injuries were similar, as well as segmental distribution of colon injuries. S/F criteria and Flint grading were similar. In RS group 15 primary repairs were successful, while in two cases relaparotomy and colostomy was performed due to anastomotic leakage. One patient died. In PR group, 25 primary repairs were successful, with 2 immediate and 3 postoperative (7-10 days deaths, with no evidence of anastomotic leakage. Conclusions Results of this study justify more liberal use of primary repair in early management of colon injuries. Trial registration Current Controlled Trials ISRCTN94682396

  6. Retinal detachment repair

    Science.gov (United States)

    ... medicines Problems breathing You may not recover full vision. ... detachments can be repaired. Failure to repair the retina always results in loss of vision to some degree. After surgery, the quality of ...

  7. Role of DNA lesions and repair in the transformation of human cells

    International Nuclear Information System (INIS)

    Maher, V.M.; McCormick, J.J.

    1987-01-01

    Results of studies on the transformation of diploid human fibroblasts in culture into tumor-forming cells by exposure to chemical carcinogens or radiation indicate that such transformation is multi-stepped process that at least one step, acquisition of anchorage independence, occurs as a mutagenic event. Studies comparing normal-repairing human cells with DNA repair-deficient cells, such as those derived from cancer-prone xeroderma pigmentosum patients, indicate that excision repair in human fibroblasts is essentially an error-free process that the ability to excise potentially cytotoxic, mutagenic, or transforming lesions induced DNA by carcinogens determines their ultimate biological consequences. Cells deficient in excision repair are abnormally sensitive to these agents. Studies with cells treated at various times in the cell cycle show that there is a certain limited amount of time available for DNA repair between the initial exposure and the onset of the cellular event responsible for mutation induction and transformation to anchorage independence. The data suggest that DNA replication on a template containing unexcised lesions (photoproducts, adducts) is the critical event

  8. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian; Li, Zhixu; Gu, Binbin; Xie, Qing; Zhu, Jia; Zhang, Xiangliang; Li, Guoliang

    2016-01-01

    turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes

  9. A novel method for monitoring functional lesion-specific recruitment of repair proteins in live cells

    Energy Technology Data Exchange (ETDEWEB)

    Woodrick, Jordan; Gupta, Suhani; Khatkar, Pooja; Dave, Kalpana; Levashova, Darya; Choudhury, Sujata; Elias, Hadi; Saha, Tapas; Mueller, Susette; Roy, Rabindra, E-mail: rr228@georgetown.edu

    2015-05-15

    Highlights: • A method of monitoring lesion-specific recruitment of proteins in vivo is described. • Recruitment of repair enzymes to abasic sites is monitored by co-localization. • Repair protein recruitment is consistent with known protein–protein relationships. • Cells demonstrated complete repair of abasic sites by 90 min. - Abstract: DNA–protein relationships have been studied by numerous methods, but a particular gap in methodology lies in the study of DNA adduct-specific interactions with proteins in vivo, which particularly affects the field of DNA repair. Using the repair of a well-characterized and ubiquitous adduct, the abasic (AP) site, as a model, we have developed a comprehensive method of monitoring DNA lesion-specific recruitment of proteins in vivo over time. We utilized a surrogate system in which a Cy3-labeled plasmid containing a single AP-site was transfected into cells, and the interaction of the labeled DNA with BER enzymes, including APE1, Polβ, LIG1, and FEN1, was monitored by immunofluorescent staining of the enzymes by Alexafluor-488-conjugated secondary antibody. The recruitment of enzymes was characterized by quantification of Cy3-Alexafluor-488 co-localization. To validate the microscopy-based method, repair of the transfected AP-site DNA was also quantified at various time points post-transfection using a real time PCR-based method. Notably, the recruitment time kinetics for each enzyme were consistent with AP-site repair time kinetics. This microscopy-based methodology is reliable in detecting the recruitment of proteins to specific DNA substrates and can be extended to study other in vivo DNA–protein relationships in any DNA sequence and in the context of any DNA structure in transfectable proliferating or quiescent cells. The method may be applied to a variety of disciplines of nucleic acid transaction pathways, including repair, replication, transcription, and recombination.

  10. A novel method for monitoring functional lesion-specific recruitment of repair proteins in live cells

    International Nuclear Information System (INIS)

    Woodrick, Jordan; Gupta, Suhani; Khatkar, Pooja; Dave, Kalpana; Levashova, Darya; Choudhury, Sujata; Elias, Hadi; Saha, Tapas; Mueller, Susette; Roy, Rabindra

    2015-01-01

    Highlights: • A method of monitoring lesion-specific recruitment of proteins in vivo is described. • Recruitment of repair enzymes to abasic sites is monitored by co-localization. • Repair protein recruitment is consistent with known protein–protein relationships. • Cells demonstrated complete repair of abasic sites by 90 min. - Abstract: DNA–protein relationships have been studied by numerous methods, but a particular gap in methodology lies in the study of DNA adduct-specific interactions with proteins in vivo, which particularly affects the field of DNA repair. Using the repair of a well-characterized and ubiquitous adduct, the abasic (AP) site, as a model, we have developed a comprehensive method of monitoring DNA lesion-specific recruitment of proteins in vivo over time. We utilized a surrogate system in which a Cy3-labeled plasmid containing a single AP-site was transfected into cells, and the interaction of the labeled DNA with BER enzymes, including APE1, Polβ, LIG1, and FEN1, was monitored by immunofluorescent staining of the enzymes by Alexafluor-488-conjugated secondary antibody. The recruitment of enzymes was characterized by quantification of Cy3-Alexafluor-488 co-localization. To validate the microscopy-based method, repair of the transfected AP-site DNA was also quantified at various time points post-transfection using a real time PCR-based method. Notably, the recruitment time kinetics for each enzyme were consistent with AP-site repair time kinetics. This microscopy-based methodology is reliable in detecting the recruitment of proteins to specific DNA substrates and can be extended to study other in vivo DNA–protein relationships in any DNA sequence and in the context of any DNA structure in transfectable proliferating or quiescent cells. The method may be applied to a variety of disciplines of nucleic acid transaction pathways, including repair, replication, transcription, and recombination

  11. Inguinal hernia repair among men in relation to occupational mechanical exposures and lifestyle factors

    DEFF Research Database (Denmark)

    Vad, Marie Vestergaard; Frost, Poul; Rosenberg, Jacob

    2017-01-01

    showed lower HRs for both repair types. Leisure-time physical activity and smoking status were not related to any of the outcomes. CONCLUSIONS: Assuming a causal relationship, the results suggest that around 30% of all first-time lateral inguinal hernia repairs in the highest exposure category would...

  12. Complex networks under dynamic repair model

    Science.gov (United States)

    Chaoqi, Fu; Ying, Wang; Kun, Zhao; Yangjun, Gao

    2018-01-01

    Invulnerability is not the only factor of importance when considering complex networks' security. It is also critical to have an effective and reasonable repair strategy. Existing research on network repair is confined to the static model. The dynamic model makes better use of the redundant capacity of repaired nodes and repairs the damaged network more efficiently than the static model; however, the dynamic repair model is complex and polytropic. In this paper, we construct a dynamic repair model and systematically describe the energy-transfer relationships between nodes in the repair process of the failure network. Nodes are divided into three types, corresponding to three structures. We find that the strong coupling structure is responsible for secondary failure of the repaired nodes and propose an algorithm that can select the most suitable targets (nodes or links) to repair the failure network with minimal cost. Two types of repair strategies are identified, with different effects under the two energy-transfer rules. The research results enable a more flexible approach to network repair.

  13. Analysis of failed rotator cuff repair – Retrospective survey of revisions after open rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Rupert Schupfner

    2017-07-01

    Full Text Available Background Rotator cuff defects are frequently occurring shoulder pathologies associated with pain and movement impairment. Aims The aim of the study was to analyse the pathologies that lead to operative revisions after primary open rotator cuff repair. Methods In 216 patients who underwent primary rotator cuff repair and later required operative revision between 1996 to 2005, pathologies found intraoperatively during the primary operation and during revision surgery were collected, analysed and compared. Results The average age at the time of revision surgery was 54.3 years. The right shoulder (61.6 per cent was more often affected than the left, males (63.4 per cent more often than females. At primary operation – apart from rotator cuff repair – there were the following surgical procedures performed: 190 acromioplasty, 86 Acromiclavicular joint resections, 68 tenodesis, 40 adhesiolysis and 1 tenotomy. If an ACJ-resection had been performed in the primary operation, ACJ-problems were rare in revision surgery (p<0.01. Primary gleno-humeral adhesions were associated with a significant rise in re-tearing rate (p=0.049. Primary absence of adhesions went along with a significant lower rate of adhesions found at revision (p=0.018. Primary performed acromioplasty had no influence on re-tearing rate (p=0.408 or on the rate of subacromial impingement at revision surgery (p=0.709. Conclusion To avoid operative revision after rotator cuff repair relevant copathologies of the shoulder have to be identified before or during operation and treated accordingly. Therefore, even during open rotator cuff repair, the surgeon should initially start with arthroscopy of the shoulder joint and subacromial space to recognise co-pathologies.

  14. Advanced inspection and repair techniques for primary side components

    International Nuclear Information System (INIS)

    Elm, Ralph

    1998-01-01

    The availability of nuclear power plant mainly depends on the components of the Nuclear Steam Supply System (NSSS) such as reactor pressure vessel, core internals and steam generators. The last decade has been characterized by intensive inspection and repair work on PWR steam generators. In the future, it can be expected, that the inspection of the reactor pressure vessel and the inspection and repair of its internals, in both PWR and BWR will be one of the challenges for the nuclear community. Due to this challenge, new, advanced inspection and repair techniques for the vital primary side components have been developed and applied, taking into account such issues as: use of reliable and fast inspection methods, repair of affected components instead of costly replacement, reduction of outage time compared to conventional methods, minimized radiation exposure, acceptable costs. This paper reflects on advanced inspection and repair techniques such as: Baffle Former Bolt inspection and replacement, Barrel Former Bolt inspection and replacement, Mechanized UT and visual inspection of reactor pressure vessels, Steam Generator repair by advanced sleeving technology. The techniques described have been successfully applied in nuclear power plants and improved the operation performance of the components and the NPP. (author). 6 figs

  15. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material.

    Science.gov (United States)

    Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M

    2008-11-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P row specimens was significantly higher than in others (P 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.

  16. DNA repair: Dynamic defenders against cancer and aging

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, Jill O.; Cooper, Priscilla K.

    2006-04-01

    You probably weren't thinking about your body's cellular DNA repair systems the last time you sat on the beach in the bright sunshine. Fortunately, however, while you were subjecting your DNA to the harmful effects of ultraviolet light, your cells were busy repairing the damage. The idea that our genetic material could be damaged by the sun was not appreciated in the early days of molecular biology. When Watson and Crick discovered the structure of DNA in 1953 [1], it was assumed that DNA is fundamentally stable since it carries the blueprint of life. However, over 50 years of research have revealed that our DNA is under constant assault by sunlight, oxygen, radiation, various chemicals, and even our own cellular processes. Cleverly, evolution has provided our cells with a diverse set of tools to repair the damage that Mother Nature causes. DNA repair processes restore the normal nucleotide sequence and DNA structure of the genome after damage [2]. These responses are highly varied and exquisitely regulated. DNA repair mechanisms are traditionally characterized by the type of damage repaired. A large variety of chemical modifications can alter normal DNA bases and either lead to mutations or block transcription if not repaired, and three distinct pathways exist to remove base damage. Base excision repair (BER) corrects DNA base alterations that do not distort the overall structure of the DNA helix such as bases damaged by oxidation resulting from normal cellular metabolism. While BER removes single damaged bases, nucleotide excision repair (NER) removes short segments of nucleotides (called oligonucleotides) containing damaged bases. NER responds to any alteration that distorts the DNA helix and is the mechanism responsible for repairing bulky base damage caused by carcinogenic chemicals such as benzo [a]pyrene (found in cigarette smoke and automobile exhaust) as well as covalent linkages between adjacent pyrimidine bases resulting from the ultraviolet

  17. Speed of recovery after arthroscopic rotator cuff repair.

    Science.gov (United States)

    Kurowicki, Jennifer; Berglund, Derek D; Momoh, Enesi; Disla, Shanell; Horn, Brandon; Giveans, M Russell; Levy, Jonathan C

    2017-07-01

    The purpose of this study was to delineate the time taken to achieve maximum improvement (plateau of recovery) and the degree of recovery observed at various time points (speed of recovery) for pain and function after arthroscopic rotator cuff repair. An institutional shoulder surgery registry query identified 627 patients who underwent arthroscopic rotator cuff repair between 2006 and 2015. Measured range of motion, patient satisfaction, and patient-reported outcome measures were analyzed for preoperative, 3-month, 6-month, 1-year, and 2-year intervals. Subgroup analysis was performed on the basis of tear size by retraction grade and number of anchors used. As an entire group, the plateau of maximum recovery for pain, function, and motion occurred at 1 year. Satisfaction with surgery was >96% at all time points. At 3 months, 74% of improvement in pain and 45% to 58% of functional improvement were realized. However, only 22% of elevation improvement was achieved (P rotation. Smaller tears had higher motion and functional scores across all time points. Tear size did not influence pain levels. The plateau of maximum recovery after rotator cuff repair occurred at 1 year with high satisfaction rates at all time points. At 3 months, approximately 75% of pain relief and 50% of functional recovery can be expected. Larger tears have a slower speed of recovery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. 49 CFR 1242.42 - Administration, repair and maintenance, machinery repair, equipment damaged, dismantling retired...

    Science.gov (United States)

    2010-10-01

    ... repair, equipment damaged, dismantling retired property, fringe benefits, other casualties and insurance, lease rentals, joint facility rents, other rents, depreciation, joint facility, repairs billed to others... maintenance, machinery repair, equipment damaged, dismantling retired property, fringe benefits, other...

  19. Laparoscopic Pediatric Inguinal Hernia Repair: Overview of "True Herniotomy" Technique and Review of Current Evidence.

    Science.gov (United States)

    Feehan, Brendan P; Fromm, David S

    2017-05-01

    Inguinal hernia repair is one of the most commonly performed operations in the pediatric population. While the majority of pediatric surgeons routinely use laparoscopy in their practices, a relatively small number prefer a laparoscopic inguinal hernia repair over the traditional open repair. This article provides an overview of the three port laparoscopic technique for inguinal hernia repair, as well as a review of the current evidence with respect to visualization and identification of hernias, recurrence rates, operative times, complication rates, postoperative pain, and cosmesis. The laparoscopic repair presents a viable alternative to open repair and offers a number of benefits over the traditional approach. These include superior visualization of the relevant anatomy, ability to assess and repair a contralateral hernia, lower rates of metachronous hernia, shorter operative times in bilateral hernia, and the potential for lower complication rates and improved cosmesis. This is accomplished without increasing recurrence rates or postoperative pain. Further research comparing the different approaches, including standardization of techniques and large randomized controlled trials, will be needed to definitively determine which is superior. Copyright© South Dakota State Medical Association.

  20. The influence of radio- and chemotherapy on DNA repair of peripheral lymphocytes of tumor patients

    International Nuclear Information System (INIS)

    Klein, W.; Alth, G.; Klein, H.; Koren, H.

    1979-07-01

    The influence of radiotherapy and chemotherapy, respectively, on DNA excision repair was investigated in lymphocytes of the peripheral blood of 10 and 5 patients with malignancies. No effects on DNA repair were found using only betatrone of 60 Co-irradiation under normal conditions. Combination of both irradiation schedules over a longer period of therapy provoked an inhibition of DNA repair. Chemotherapy inhibits DNA repair immediately after starting therapy, but after relatively short time, the extent of DNA repair increases above normal level. (author)

  1. Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign targets meaningful risk reduction in the Collision Repair source category to reduce air toxic emissions in their communities. The Campaign also helps shops to work towards early compliance with the Auto Body Rule.

  2. Editor's Choice - Prolonged ICU Length of Stay after AAA Repair: Analysis of Time Trends and Long-term Outcome.

    Science.gov (United States)

    Gavali, H; Mani, K; Tegler, G; Kawati, R; Covaciu, L; Wanhainen, A

    2017-08-01

    The aim of the study was to investigate the frequency and outcome of prolonged intensive care unit (ICU) length of stay (LOS) after abdominal aortic aneurysm (AAA) repair in the endovascular era. All patients operated on for AAA between 1999 and 2013 at Uppsala University hospital were identified. Data were retrieved from the Swedish Vascular registry, the Swedish Intensive Care registry, the National Population registry, and case records. Prolonged ICU LOS was defined as ≥ 48 h during the primary hospital stay. Patients surviving ≥ 48 h after AAA surgery were included in the analysis. A total of 725 patients were identified, of whom 707 (97.5%) survived ≥ 48 h; 563 (79.6%) underwent intact AAA repair and 144 (20.4%) ruptured AAA repair. A total of 548 patients (77.5%) required AAA repairs in 1999 to 7.3% in 2013 (p < .001) whereas the use of endovascular aortic repair (EVAR) increased from 6.9% in 1999 to 78.0% in 2013 (p < .001). The 30 day survival rate was 98.2% for those with < 48 h ICU stay versus 93.0% for 2-6 days versus 81.8% for ≥ 7 days (p < .001); the corresponding 90 day survival was 97.1% versus 86.1% versus 63.6% (p < .001) respectively. For patients surviving 90 days after repair, there was no difference in long-term survival between the groups. During the period of progressively increasing use of EVAR, a simultaneous significant reduction in frequency of prolonged ICU LOS occurred. Although prolonged ICU LOS was associated with a high short-term mortality, long-term outcome among those surviving the initial 90 days was less affected. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Repair mechanisms and exposure standards

    International Nuclear Information System (INIS)

    Mills, W.A.

    1978-01-01

    The following topics are discussed; public policy for setting radiation standards; use of linear, nonthreshold theory in setting radiation standards; dose-rate dependence; occupational exposure to radiation; radon inhalation from radium in the soil in the vicinity of the phosphate industry; relation of repair mechanisms for cell survival to cancer induction; application of information on genetic repair to humans and to cancer induction; importance of repair processes in radiation protection standards; corrective factors for repair processes; relation of repair processes to age, sex, and other factors; and population distribution in radiosensitivity

  4. Laparoscopic repair of postoperative perineal hernia.

    LENUS (Irish Health Repository)

    Ryan, Stephen

    2010-01-01

    Perineal hernias are infrequent complications following abdominoperineal operations. Various approaches have been described for repair of perineal hernias including open transabdominal, transperineal or combined abdominoperineal repairs. The use of laparoscopic transabdominal repair of perineal hernias is not well-described. We present a case report demonstrating the benefits of laparoscopic repair of perineal hernia following previous laparoscopic abdominoperineal resection (APR) using a nonabsorbable mesh to repair the defect. We have demonstrated that the use of laparoscopy with repair of the pelvic floor defect using a non absorbable synthetic mesh offers an excellent alternative with many potential advantages over open transabdominal and transperineal repairs.

  5. Laser-activated protein solder for peripheral nerve repair

    Science.gov (United States)

    Trickett, Rodney I.; Lauto, Antonio; Dawes, Judith M.; Owen, Earl R.

    1995-05-01

    A 100 micrometers core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the albumin based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 +/- 5 min. (n equals 20) compared to 23 +/- 9 min. (n equals 10) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 +/- 5 g, while microsutured nerves had a tensile strength of 40 +/- 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study is under way comparing laser solder repaired tibial nerves to conventional microsuture repair. At the time of submission 15 laser soldered nerves and 7 sutured nerves were characterized at 3 months and showed successful regeneration with compound muscle action potentials of 27 +/- 8 mV and 29 +/- 8 mW respectively. A faster, less damaging and long lasting laser based anastomotic technique is presented.

  6. Results of lateral ankle ligament repair surgery in one hundred and nineteen patients: do surgical method and arthroscopy timing matter?

    Science.gov (United States)

    Araoye, Ibukunoluwa; De Cesar Netto, Cesar; Cone, Brent; Hudson, Parke; Sahranavard, Bahman; Shah, Ashish

    2017-11-01

    Ankle sprains are the most common athletic injury. One of five chronic lateral ankle instability patients will require surgery, making operative outcomes crucial. The purpose of this study is to determine if operative method influences failure and complication rates in chronic lateral ankle ligament repair surgery. We retrospectively reviewed 119 cases (118 patients) of lateral ankle ligament surgery between 2006 and 2016. Patient charts and operative reports were examined for demographics, use and timing of ankle arthroscopy, ligament fixation method, type of surgical incision, presence of calcaneofibular ligament repair, and operative technique. Impact of operative methods on failure (one-year minimum follow-up) and complication outcomes was explored using Chi-square test of independence (or Fisher's exact test). Statistical significance was set at p less than .05. Mean age at surgery was 40 (range, 18-73) years. Mean follow-up was 51 (range, 12-260) weeks. Failure rate was 8.4% (10/89 cases) while complication rate was 17.6% (21/119). Failure rate did not differ significantly between any data subgroups (p > .05). Single stage arthroscopy was associated with a significantly lower complication rate (11%, 4/37) than double-stage arthroscopy (47%, 9/19) (p anchor ligament fixation (9%, 6/67) compared to direct suture ligament fixation (29%, 15/52) (p anchors and concurrent ankle arthroscopy may be favourable options to achieve fewer complications in chronic lateral ankle instability repair surgery.

  7. Systems with randomly failing repairable components

    DEFF Research Database (Denmark)

    Der Kiureghian, Armen; Ditlevsen, Ove Dalager; Song, Junho

    2005-01-01

    Closed-form expressions are derived for the steady-state availability, mean rate of failure, mean duration of downtime and reliability of a general system with randomly and independently failing repairable components. Component failures are assumed to be homogeneous Poisson events in time and rep...

  8. Short- and long-term results following standing fracture repair in 34 horses.

    Science.gov (United States)

    Payne, R J; Compston, P C

    2012-11-01

    Standing fracture repair in the horse is a recently described surgical procedure and currently there are few follow-up data. This case series contains 2 novel aspects in the standing horse: repair of incomplete sagittal fractures of the proximal phalanx and medial condylar repair from a lateral aspect. To describe outcome in a case series of horses that had lower limb fractures repaired under standing sedation at Rossdales Equine Hospital. Case records for all horses that had a fracture surgically repaired, by one surgeon at Rossdales Equine Hospital, under standing sedation and local anaesthesia up until June 2011, were retrieved. Hospital records, owner/trainer telephone questionnaire and the Racing Post website were used to evaluate follow-up. Thirty-four horses satisfied the inclusion criteria. Fracture sites included the proximal phalanx (incomplete sagittal fracture, n = 14); the third metacarpal bone (lateral condyle, n = 12, and medial condyle, n = 7); and the third metatarsal bone (lateral condyle, n = 1). One horse required euthanasia due to caecal rupture 10 days post operatively. Twenty horses (66.7% of those with available follow-up) have returned to racing. Where available, mean time from operation to return to racing was 226 days (range 143-433 days). Standing fracture repair produced similar results to fracture repair under general anaesthesia in terms of both the number of horses that returned to racing and the time between surgery and race. Repair of lower limb fracture in the horse under standing sedation is a procedure that has the potential for tangible benefits, including avoidance of the inherent risks of general anaesthesia. The preliminary findings in this series of horses are encouraging and informative when discussing options available prior to fracture repair. © 2012 EVJ Ltd.

  9. Transfer of Chinese hamster DNA repair gene(s) into repair-deficient human cells (Xeroderma pigmentosum)

    International Nuclear Information System (INIS)

    Karentz, D.; Cleaver, J.E.

    1985-01-01

    Transfer of repair genes by DNA transfection into repair-deficient Xeroderma pigmentosum (XP) cells has thus far been unsuccessful, presenting an obstacle to cloning XP genes. The authors chose an indirect route to transfer repair genes in chromosome fragments. DNA repair-competent (UV resistant) hybrid cell lines were established by PEG-mediated fusions of DNA repair-deficient (UV sensitive) human fibroblasts (XP12RO) with wild type Chinese hamster (CHO) cells (AA8). CHO cells were exposed to 5 Krad X-rays prior to fusions, predisposing hybrid cells to lose CHO chromosome fragments preferentially. Repair-competent hybrids were selected by periodic exposures to UV light. Secondary and tertiary hybrid cell lines were developed by fusion of X-irradiated hybrids to XP12RO. The hybrid cell lines exhibit resistance to UV that is comparable to that of CHO cells and they are proficient at repair replication after UV exposure. Whole cell DNA-DNA hybridizations indicate that the hybrids have greater homology to CHO DNA than is evident between XP12RO and CHO. These observations indicate that CHO DNA sequences which can function in repair of UV-damaged DNA in human cells have been transferred into the genome of the repair-deficient XP12RO cells

  10. Relying on Visiting Foreign Doctors for Fistula Repair: The Profile of Women Attending Fistula Repair Surgery in Somalia.

    Science.gov (United States)

    Gele, Abdi A; Salad, Abdulwahab M; Jimale, Liban H; Kour, Prabhjot; Austveg, Berit; Kumar, Bernadette

    2017-01-01

    Obstetric fistula is treatable by surgery, although access is usually limited, particularly in the context of conflict. This study examines the profile of women attending fistula repair surgery in three hospitals in Somalia. A cross-sectional study was conducted in Somalia from August to September 2016. Structured questionnaires were administered to 81 women who registered for fistula repair surgery in the Garowe, Daynile, and Kismayo General Hospitals in Somalia. Findings revealed that 70.4% of the study participants reported obstetric labor as the cause of their fistula, and 29.6% reported iatrogenic causes. Regarding the waiting time for the repair surgery, 45% waited for the surgery for over one year, while the rest received the surgery within a year. The study suggests that training for fistula surgery has to be provided for healthcare professionals in Somalia, fistula centers should be established, and access to these facilities has to be guaranteed for all patients who need these services.

  11. Tricuspid Valve Repair for the Poor Right Ventricle: Tricuspid Valve Repair in Patients with Mild-to-Moderate Tricuspid Regurgitation Undergoing Mitral Valve Repair Improves In-Hospital Outcome.

    Science.gov (United States)

    Zientara, Alicja; Genoni, Michele; Graves, Kirk; Odavic, Dragan; Löblein, Helen; Häussler, Achim; Dzemali, Omer

    2017-12-01

    Background  Tricuspid regurgitation (TR) in patients undergoing surgery for mitral valve (MV) increases morbidity and mortality, especially in case of a poor right ventricle. Does repair of mild-to-moderate insufficiency of the tricuspid valve (TV) in patients undergoing MV surgery lead to a benefit in early postoperative outcome? Methods  A total of 22 patients with mild-to-moderate TR underwent MV repair and concomitant TV repair with Tri-Ad (Medtronic ATS Medical Inc., Minneapolis, Minnesota, United States) and Edwards Cosgrove (Edwards Lifesciences Irvine, California, United States) rings. The severity of TR was assessed echocardiographically by using color-Doppler flow images. The tricuspid annular plane systolic excursion (TAPSE) was under 1.7 cm. Additional procedures included coronary artery bypass ( n  = 9) and maze procedure ( n  = 15). The following parameters were compared: postoperative and peak dose of noradrenaline (NA), pre/postoperative systolic pulmonary pressure (sPAP), extubation time, operation time, cross-clamp time, cardiopulmonary bypass (CPB) time, pre/postoperative ejection fraction (EF), intensive care unit (ICU)-stay, hospital stay, cell saver blood transfusion, intra/postoperative blood transfusion, and postoperative TR. Results  The mean age was 67 ± 14.8 years, 45% were male. Mean EF was 47 ± 16.2%, postoperative 52 ± 12.4%. sPAP was 46 ± 20.1 mm Hg preoperatively, sPAP was 40.6 ± 9.4 mm Hg postoperatively, NA postoperatively was 12 ± 10 μg/min, NA peak was 18 ± 11 μg/min, operation time was 275 ± 92 minutes, CPB was 145 ± 49 minutes, ICU stay was 2.4 ± 2.4 days, hospital stay was 10.8 ± 3.5 days, cell saver blood transfusion was 736 ± 346 mL, intraoperative transfusions were 2.5 ± 1.6. Two patients needed postoperative transfusions. A total of 19 patients were extubated at the 1st postoperative day, 2 patients at the 2nd day, and 1 at the 4th

  12. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    Full Text Available ABSTRACT Objective: The purpose of this video is to present the laparoscopic repair of a VUF in a 42-year-old woman, with gross hematuria, in the immediate postoperative phase following a cesarean delivery. The obstetric team implemented conservative management, including Foley catheter insertion, for 2 weeks. She subsequently developed intermittent hematuria and cystitis. The urology team was consulted 15 days after cesarean delivery. Cystoscopy indicated an ulcerated lesion in the bladder dome of approximately 1.0cm in size. Hysterosalpingography and a pelvic computed tomography scan indicated a fistula. Materials and Methods: Laparoscopic repair was performed 30 days after the cesarean delivery. The patient was placed in the lithotomy position while also in an extreme Trendelenburg position. Pneumoperitoneum was established using a Veress needle in the midline infra-umbilical region, and a primary 11-mm port was inserted. Another 11-mm port was inserted exactly between the left superior iliac spine and the umbilicus. Two other 5-mm ports were established under laparoscopic guidance in the iliac fossa on both sides. The omental adhesions in the pelvis were carefully released and the peritoneum between the bladder and uterus was incised via cautery. Limited cystotomy was performed, and the specific sites of the fistula and the ureteral meatus were identified; thereafter, the posterior bladder wall was adequately mobilized away from the uterus. The uterine rent was then closed using single 3/0Vicryl sutures and two-layer watertight closure of the urinary bladder was achieved by using 3/0Vicryl sutures. An omental flap was mobilized and inserted between the uterus and the urinary bladder, and was fixed using two 3/0Vicryl sutures, followed by tube drain insertion. Results: The operative time was 140 min, whereas the blood loss was 100ml. The patient was discharged 3 days after surgery, and the catheter was removed 12 days after surgery

  13. Optimization of Aeroengine Shop Visit Decisions Based on Remaining Useful Life and Stochastic Repair Time

    Directory of Open Access Journals (Sweden)

    Jing Cai

    2016-01-01

    Full Text Available Considering the wide application of condition-based maintenance in aeroengine maintenance practice, it becomes possible for aeroengines to carry out their preventive maintenance in just-in-time (JIT manner by reasonably planning their shop visits (SVs. In this study, an approach is proposed to make aeroengine SV decisions following the concept of JIT. Firstly, a state space model (SSM for aeroengine based on exhaust gas temperature margin is developed to predict the remaining useful life (RUL of aeroengine. Secondly, the effect of SV decisions on risk and service level (SL is analyzed, and an optimization of the aeroengine SV decisions based on RUL and stochastic repair time is performed to carry out JIT manner with the requirement of safety and SL. Finally, a case study considering two CFM-56 aeroengines is presented to demonstrate the proposed approach. The results show that predictive accuracy of RUL with SSM is higher than with linear regression, and the process of SV decisions is simple and feasible for airlines to improve the inventory management level of their aeroengines.

  14. Indentation damage and crack repair in human enamel.

    Science.gov (United States)

    Rivera, C; Arola, D; Ossa, A

    2013-05-01

    Tooth enamel is the hardest and most highly mineralized tissue in the human body. While there have been a number of studies aimed at understanding the hardness and crack growth resistance behavior of this tissue, no study has evaluated if cracks in this tissue undergo repair. In this investigation the crack repair characteristics of young human enamel were evaluated as a function of patient gender and as a function of the distance from the Dentin Enamel Junction (DEJ). Cracks were introduced via microindentation along the prism direction and evaluated as a function of time after the indentation. Microscopic observations indicated that the repair of cracks began immediately after crack initiation and reaches saturation after approximately 48 h. During this process he crack length decreased up to 10% of the initial length, and the largest degree of reduction occurred in the deep enamel, nearest the DEJ. In addition, it was found that the degree of repair was significantly greater in the enamel of female patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Reliable pipeline repair system for very large pipe size

    Energy Technology Data Exchange (ETDEWEB)

    Charalambides, John N.; Sousa, Alexandre Barreto de [Oceaneering International, Inc., Houston, TX (United States)

    2004-07-01

    The oil and gas industry worldwide has been mainly depending on the long-term reliability of rigid pipelines to ensure the transportation of hydrocarbons, crude oil, gas, fuel, etc. Many other methods are also utilized onshore and offshore (e.g. flexible lines, FPSO's, etc.), but when it comes to the underwater transportation of very high volumes of oil and gas, the industry commonly uses large size rigid pipelines (i.e. steel pipes). Oil and gas operators learned to depend on the long-lasting integrity of these very large pipelines and many times they forget or disregard that even steel pipelines degrade over time and more often that that, they are also susceptible to various forms of damage (minor or major, environmental or external, etc.). Over the recent years the industry had recognized the need of implementing an 'emergency repair plan' to account for such unforeseen events and the oil and gas operators have become 'smarter' by being 'pro-active' in order to ensure 'flow assurance'. When we consider very large diameter steel pipelines such as 42' and 48' nominal pipe size (NPS), the industry worldwide does not provide 'ready-made', 'off-the-shelf' repair hardware that can be easily shipped to the offshore location and effect a major repair within acceptable time frames and avoid substantial profit losses due to 'down-time' in production. The typical time required to establish a solid repair system for large pipe diameters could be as long as six or more months (depending on the availability of raw materials). This paper will present in detail the Emergency Pipeline Repair Systems (EPRS) that Oceaneering successfully designed, manufactured, tested and provided to two major oil and gas operators, located in two different continents (Gulf of Mexico, U.S.A. and Arabian Gulf, U.A.E.), for two different very large pipe sizes (42'' and 48'' Nominal Pipe Sizes

  16. Vaginal native tissue repair versus transvaginal mesh repair for apical prolapse: how utilizing different methods of analysis affects the estimated trade-off between reoperation for mesh exposure/erosion and reoperation for recurrent prolapse.

    Science.gov (United States)

    Dieter, Alexis A; Willis-Gray, Marcella G; Weidner, Alison C; Visco, Anthony G; Myers, Evan R

    2015-05-01

    Informed decision-making about optimal surgical repair of apical prolapse with vaginal native tissue (NT) versus transvaginal mesh (TVM) requires understanding the balance between the potential "harm" of mesh-related complications and the potential "benefit" of reducing prolapse recurrence. Synthesis of data from observational studies is required and the current literature shows that the average follow-up for NT repair is significantly longer than for TVM repair. We examined this harm/benefit balance. We hypothesized that using different methods of analysis to incorporate follow-up time would affect the balance of outcomes. We used a Markov state transition model to estimate the cumulative 24-month probabilities of reoperation for mesh exposure/erosion or for recurrent prolapse after either NT or TVM repair. We used four different analytic approaches to estimate probability distributions ranging from simple pooled proportions to a random effects meta-analysis using study-specific events per patient-time. As variability in follow-up time was accounted for better, the balance of outcomes became more uncertain. For TVM repair, the incremental ratio of number of operations for mesh exposure/erosion per single reoperation for recurrent prolapse prevented increased progressively from 1.4 to over 100 with more rigorous analysis methods. The most rigorous analysis showed a 70% probability that TVM would result in more operations for recurrent prolapse repair than NT. Based on the best available evidence, there is considerable uncertainty about the harm/benefit trade-off between NT and TVM for apical prolapse repair. Future studies should incorporate time-to-event analyses, with greater standardization of reporting, in order to better inform decision-making.

  17. Potential of Carbon Nanotube Reinforced Cement Composites as Concrete Repair Material

    Directory of Open Access Journals (Sweden)

    Tanvir Manzur

    2016-01-01

    Full Text Available Carbon nanotubes (CNTs are a virtually ideal reinforcing agent due to extremely high aspect ratios and ultra high strengths. It is evident from contemporary research that utilization of CNT in producing new cement-based composite materials has a great potential. Consequently, possible practical application of CNT reinforced cementitious composites has immense prospect in the field of applied nanotechnology within construction industry. Several repair, retrofit, and strengthening techniques are currently available to enhance the integrity and durability of concrete structures with cracks and spalling, but applicability and/or reliability is/are often limited. Therefore, there is always a need for innovative high performing concrete repair materials with good mechanical, rheological, and durability properties. Considering the mechanical properties of carbon nanotubes (CNTs and the test results of CNT reinforced cement composites, it is apparent that such composites could be used conveniently as concrete repair material. With this end in view, the applicability of multiwalled carbon nanotube (MWNT reinforced cement composites as concrete repair material has been evaluated in this study in terms of setting time, bleeding, and bonding strength (slant shear tests. It has been found that MWNT reinforced cement mortar has good prospective as concrete repair material since such composites exhibited desirable behavior in setting time, bleeding, and slant shear.

  18. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  19. Safety of repair for severe duodenal injuries.

    Science.gov (United States)

    Velmahos, George C; Constantinou, Constantinos; Kasotakis, George

    2008-01-01

    There is ongoing debate about the management of severe duodenal injuries (SDIs), and earlier studies have recommended pyloric exclusion. The objective of this study was to compare primary repair with pyloric exclusion to examine if primary repair can be safely used in SDIs. The medical records of 193 consecutive patients who were admitted between August 1992 and January 2004 with duodenal injuries were reviewed. After excluding early deaths (n = 50), low-grade duodenal injuries (n = 81), and pancreatoduodenectomies for catastrophic trauma (n = 12), a total of 50 patients with SDIs (grade III, IV, or V) were analyzed. Primary repair (PR--simple duodenorrhaphy or resection and primary anastomosis) was performed in 34 (68%) and pyloric exclusion (PE) in 16 (32%). Characteristics and outcomes of these two groups were compared. PE and PR patients were similar for age, injury severity score, abdominal abbreviated injury score, physiologic status on admission, time to operation, and most abdominal organs injured. PE patients had more pancreatic injuries (63% vs. 24%, p duodenum (79% vs. 42%, p = 0.02), and a nonsignificant trend toward more grade IV and V injuries (37% vs. 18%, p = 0.11). There was no difference in morbidity (including complications specific to the duodenal repair), mortality, and intensive care unit and hospital length of stay between the two groups. Pyloric exclusion is not necessary for all patients with SDIs, as previously suggested. Selected SDI patients can be safely managed by simple primary repair.

  20. Robust gap repair in the contractile ring ensures timely completion of cytokinesis.

    OpenAIRE

    Silva, AM; Osório, DS; Pereira, AJ; Maiato, H; Pinto, IM; Rubinstein, B; Gassmann, R; Telley, IA; Carvalho, AX

    2016-01-01

    Cytokinesis in animal cells requires the constriction of an actomyosin contractile ring, whose architecture and mechanism remain poorly understood. We use laser microsurgery to explore the biophysical properties of constricting rings in Caenorhabditis elegans embryos. Laser cutting causes rings to snap open. However, instead of disintegrating, ring topology recovers and constriction proceeds. In response to severing, a finite gap forms and is repaired by recruitment of new material in an acti...

  1. Tensile strength of structural concrete repaired with hi-bond polymer modified mortar

    International Nuclear Information System (INIS)

    Khaskheli, G.B.

    2009-01-01

    Repair of cracks in concrete is often required to save the concrete structures. Appearance of crack in concrete is bound with the tensile strength of concrete. Recently a cement factory in Sindh has launched a HBPMM (Hi-Bond Polymer Modified Mortar) that can be used as a concrete repairing material instead of normal OPC (Ordinary Portland Cement). It is needed to investigate its performance compared to that of OPC. In total 144 concrete cylinders (150x300mm) having strength of 3000 and 5000 psi were manufactured. These cylinders were then splitted by using a UTM (Universal Testing Machine) and their actual tensile strength was obtained. The concrete cylinders were then repaired with different applications of HBPMM and arc. The repaired samples were again splitted at different curing ages (3, 7 and 28 days) and their tensile strength after repair was obtained. The results show that the concrete cylinders repaired with HBPMM could give better tensile strength than that repaired with arc, the tensile strength of concrete cylinders after repair could increase with increase in the application of repairing material i.e. HBPMM or OPC and with curing time, and HBPMM could remain more effective in case of rich mix concrete than that of normal mix concrete. (author)

  2. Aging and DNA repair capability. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Tice, R R

    1977-01-01

    A review of the literature on DNA repair processes in relation to aging is presented under the following headings: DNA repair processes; age-related occurrence of unrepaired DNA lesions; DNA repair capability as a function of age; tissue-specific DNA repair capability; acceleration of the aging process by exposure to DNA damaging agents; human genetic syndromes; and longevity and DNA repair processes. (HLW)

  3. Repair of UV-irradiated plasmid DNA in excision repair deficient mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ikai, K.; Tano, K.; Ohnishi, T.; Nozu, K.

    1985-01-01

    The repair of UV-irradiated DNA of plasmid YEp13 was studied in the incision defective strains by measurement of cell transformation frequency. In Saccharomyces cerevisiae, rad1,2,3 and 4 mutants could repair UV-damaged plasmid DNA. In Escherichia coli, uvrA mutant was unable to repair UV-damaged plasmid DNA; however, pretreatment of the plasmid with Micrococcus luteus endonuclease increased repair. It was concluded that all the mutations of yeast were probably limited only to the nuclear DNA. (author)

  4. DNA repair in Mycobacterium tuberculosis revisited.

    Science.gov (United States)

    Dos Vultos, Tiago; Mestre, Olga; Tonjum, Tone; Gicquel, Brigitte

    2009-05-01

    Our understanding of Mycobacterium tuberculosis DNA repair mechanisms is still poor compared with that of other bacterial organisms. However, the publication of the first complete M. tuberculosis genome sequence 10 years ago boosted the study of DNA repair systems in this organism. A first step in the elucidation of M. tuberculosis DNA repair mechanisms was taken by Mizrahi and Andersen, who identified homologs of genes involved in the reversal or repair of DNA damage in Escherichia coli and related organisms. Genes required for nucleotide excision repair, base excision repair, recombination, and SOS repair and mutagenesis were identified. Notably, no homologs of genes involved in mismatch repair were identified. Novel characteristics of the M. tuberculosis DNA repair machinery have been found over the last decade, such as nonhomologous end joining, the presence of Mpg, ERCC3 and Hlr - proteins previously presumed to be produced exclusively in mammalian cells - and the recently discovered bifunctional dCTP deaminase:dUTPase. The study of these systems is important to develop therapeutic agents that can counteract M. tuberculosis evolutionary changes and to prevent adaptive events resulting in antibiotic resistance. This review summarizes our current understanding of the M. tuberculosis DNA repair system.

  5. Poolside inspection, repair and reconstitution of LWR fuel elements

    International Nuclear Information System (INIS)

    1993-03-01

    The purpose of the meeting was to review the state of the art in the area of poolside inspection, repair and reconstitution of light water fuel elements. In the present publication it appears that techniques of inspection, repair and reconstitution of fuel elements have been developed by fuel suppliers and are now routinely and successfully applied in many countries. For the first time, the subject of control rod poolside examination was dealt with, poolside inspection and repair of a MOX assembly were reported and the inspection and repair of WWER assemblies were examined. Compared to the results of the previous meeting, present developments in the area aim now at reaching better economics, better reliability, reduction of personal doses and waste volume. Thirty-six participants representing twelve countries attended the meeting. Fifteen papers were presented in two sessions. An abstract was prepared for each of these papers. Refs, figs, tabs, diagrams, pictures and photos

  6. In search of supply concepts for the mass market in the face of the energy turnaround; Auf der Suche nach massenmarktfaehigen Belieferungskonzepten fuer die Energiewende

    Energy Technology Data Exchange (ETDEWEB)

    Fest, Claus [RWE Effizienz GmbH, Dortmund (Germany); Ploch, Dieter [eprimo GmbH, Neu-Isenburg (Germany)

    2013-01-15

    There are increasing demands both in Germany and at the European level that electricity price models for household and industrial customers should be brought in line with the times by allowing greater flexibility and allocating costs to causes. In Germany they have issued from the discussion over the consequences of the energy turnaround for the mass customer business and the associated search for viable supply concepts. A number of proposals have been made to this end, largely revolving around the question of how prices for supplying end customers can be made to more closely approximate conditions as they prevail in the wholesale market while allowing price advantages to become effective. However, in many instances the public debate has so far neglected an essential factor: In order for a product to become firmly established on the market it must confer benefits to all involved, that is to both customers and suppliers.

  7. Management of 220 adolescents and adults with complications of hypospadias repair during childhood

    Directory of Open Access Journals (Sweden)

    Adam S. Howe

    2017-01-01

    Conclusion: Complications of childhood hypospadias repair may present later in life as some urethroplasties deteriorate with time. We now recommend to parents of children with repaired proximal hypospadias to come for follow-up as their child transitions to adolescence.

  8. Repair-modification of radiodamaged genes

    International Nuclear Information System (INIS)

    Volpe, P.; Institute of Experimental Medicine, Rome; Eremenko, T.

    1995-01-01

    It is proposed that through repair-modification, the modified base 5mC may have facilitated the divergent evolution of coding (hypomethylated exon) and uncoding (hypermethylated promoter and intron) sequences in eukaryotic genes. The radioinduced repair patches appearing in regions lacking 5mC are fully reconstructed by excision-repair, whereas those appearing in regions containing 5mC are incompletely reconstructed by this conventional mechanism. Such a second class of repair patches may, however, become fully reconstructed, in the S phase, by repair-modification. In fact, while DNA polymerase β - which is a key enzyme of excision-repair - is active through the whole interphase. DNA methylase - which is responsible for post-synthetic DNA modification - is essentially active in S. Uncoupling of these two enzyme systems, outside S, might explain why in unsynchronised cells repair patches of non-replicating strands are hypomethylated when compared with specific methylation of replicating strands. In other words, excision-repair would always be able to re-establish the primary ATGC language of both damaged unmethylated and methylated regions, while repair-modification would be able to re-establish the modified ATGC(5mC) language of the damaged methylated regions, only in S, but not in G 1 or G 2 . In these two phases, when DNA methylation is inversely correlated with pre-mRNA transcription (as in the case of many tissue-specific genes), such demethylation might induce a silent transcriptional unit to become active. (Author)

  9. Long-term outcome after early repair of iatrogenic bile duct injury

    DEFF Research Database (Denmark)

    Stilling, Nicolaj M; Fristrup, Claus; Wettergren, André

    2015-01-01

    BACKGROUND: The aim of this retrospective study was to evaluate the peri-operative and long-term outcome after early repair with a hepaticojejunostomy (HJ). METHODS: Between 1995 and 2010, a nationwide, retrospective multi-centre study was conducted. All iatrogenic bile duct injury (BDI) sustained...... during a cholecystectomy and repaired with HJ in the five Hepato-Pancreatico-Biliary centres in Denmark were included. RESULTS: In total, 139 patients had an HJ repair. The median time from the BDI to reconstruction was 5 days. A concomitant vascular injury was identified in 26 cases (19%). Post...... with BDI repaired by early HJ we found a considerable risk of long-term complications (e.g. 30% stricture rate) and mortality in both the short- and the long-term perspective....

  10. Differential recruitment of DNA Ligase I and III to DNA repair sites

    Science.gov (United States)

    Mortusewicz, Oliver; Rothbauer, Ulrich; Cardoso, M. Cristina; Leonhardt, Heinrich

    2006-01-01

    DNA ligation is an essential step in DNA replication, repair and recombination. Mammalian cells contain three DNA Ligases that are not interchangeable although they use the same catalytic reaction mechanism. To compare the recruitment of the three eukaryotic DNA Ligases to repair sites in vivo we introduced DNA lesions in human cells by laser microirradiation. Time lapse microscopy of fluorescently tagged proteins showed that DNA Ligase III accumulated at microirradiated sites before DNA Ligase I, whereas we could detect only a faint accumulation of DNA Ligase IV. Recruitment of DNA Ligase I and III to repair sites was cell cycle independent. Mutational analysis and binding studies revealed that DNA Ligase I was recruited to DNA repair sites by interaction with PCNA while DNA Ligase III was recruited via its BRCT domain mediated interaction with XRCC1. Selective recruitment of specialized DNA Ligases may have evolved to accommodate the particular requirements of different repair pathways and may thus enhance efficiency of DNA repair. PMID:16855289

  11. Repair promoted by plasmid pKM101 is different from SOS repair

    International Nuclear Information System (INIS)

    Goze, A.; Devoret, R.

    1979-01-01

    In E. coli K12 bacteria carrying plasmid pKM101, prophage lambda was induced at UV doses higher than in plasmid-less parental bacteria. UV-induced reactivation per se was less effective. Bacteria with pKM101 showed no alteration in their division cycle. Plasmid PKM101 coded for a constitutive error-prone repair different from the inducible error-prone repair called SOS repair. Plasmid pKM101 protected E. coli bacteria from UV damage but slightly sensitized them to X-ray lesions. Protection against UV damage was effective in mutant bacteria deficient in DNA excision-repair provided that the recA, lexA and uvrE genes were functional. Survival of phages lambda and S13 after UV irradiation was enhanced in bacteria carrying plasmid pKM101; phage lambda mutagenesis was also increased. Plasmid pKM101 repaired potentially lethal DNA lesions, although Wild-type DNA sequences may not necessarily be restored; hence the mutations observed are the traces of the original DNA lesions. (Auth.)

  12. Cold standby repairable system with working vacations and vacation interruption

    Institute of Scientific and Technical Information of China (English)

    Baoliang Liu; Lirong Cui; Yanqing Wen

    2015-01-01

    This paper studies a cold standby repairable system with working vacations and vacation interruption. The repairman’s multiple vacations policy, the working vacations policy and the vacation interruption are considered simultaneously. The lifetime of components fol ows a phase-type (PH) distribution. The repair time in the regular repair period and the working vacation period fol ow other two PH distributions at different rates. For this sys-tem, the vector-valued Markov process governing the system is constructed. We obtain several important performance measures for the system in transient and stationary regimes applying matrix-analytic methods. Final y, a numerical example is given to il ustrate the results obtained.

  13. AVACOM-ETAP, Availability and Element Transient and Asymptotic Repair Process

    International Nuclear Information System (INIS)

    Reina, G.

    1987-01-01

    1 - Description of program or function: In reliability theory, the term 'availability' generally indicates the probability of the proper functioning of a system or of a component at a general time t when various possible replacement or repair policies are considered. AVACOM-ETARP calculates the transient and asymptotic availability of a component subject to a repair process with generic failure and repair laws. Five of the most commonly used distributions have been included as options: exponential, normal; lognormal; gamma; Weibull. 2 - Method of solution: The used mathematical model considers the failure-restoration process as a 2-state non-homogeneous Markov process containing the homogeneous Markov one as a particular case

  14. Cleft lip and palate repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002979.htm Cleft lip and palate repair To use the sharing features on this ... Cheiloplasty; Cleft rhinoplasty; Palatoplasty; Tip rhinoplasty Patient Instructions Cleft lip and palate repair - discharge Images Cleft lip repair - series References ...

  15. Some important advances in DNA repair study on the mammalian cells

    International Nuclear Information System (INIS)

    Xia Shouxuan.

    1991-01-01

    In the recent years the study of DNA damage and repair in the mammalian cells has gone deeply at gene level and got the following advances: (1) For a long time DNA has been considered to be an uniform unit in case of damage and repair. Now this concept should be replaced by the non-random distribution of damage and heterogenous repair in the genome. These would allow us to study cellular mutagenesis, carcinogenesis, aging and dying processes in great detail, and would be beneficial to the elucidation of mechanisms of radiation sickness and chemical toxicology. (2) The advent of new techniques in molecular biology has made it possible to isolate and clone the human DNA repair genes. Up to now more than ten human DNA repair genes have been cloned and these works would have an important impact on the theoretical and practical study in this field. Because DNA repair system is very complicate, voluminous work should be done in the future. (3) The technique of gene transfer has been efficiently used in the study of DNA repair in mammalian cells and has made great contribution in the cellular engineering. It could modify the genetic behavior of the gene-accepting cells, and enhance the DNA repair ability to physical and chemical damages. Human gene therapy for DNA deficient diseases is now on the day

  16. Deficient repair of chemical adducts in alpha DNA of monkey cells

    International Nuclear Information System (INIS)

    Zolan, M.E.; Cortopassi, G.A.; Smith, C.A.; Hanawalt, P.C.

    1982-01-01

    Researchers have examined excision repair of DNA damage in the highly repeated alpha DNA sequence of cultured African green monkey cells. Irradiation of cells with 254 nm ultraviolet light resulted in the same frequency of pyrimidine dimers in alpha DNA and the bulk of the DNA. The rate and extent of pyrimidine dimer removal, as judged by measurement of repair synthesis, was also similar for alpha DNA and bulk DNA. In cells treated with furocoumarins and long-wave-length ultraviolet light, however, repair synthesis in alpha DNA was only 30% of that in bulk DNA, although it followed the same time course. Researchers found that this reduced repair was not caused by different initial amounts of furocoumarin damage or by different sizes of repair patches, as researchers found these to be similar in the two DNA species. Direct quantification demonstrated that fewer furocoumarin adducts were removed from alpha DNA than from bulk DNA. In cells treated with another chemical DNA-damaging agent, N-acetoxy-2-acetylaminofluorene, repair synthesis in alpha DNA was 60% of that in bulk DNA. These results show that the repair of different kinds of DNA damage can be affected to different extents by some property of this tandemly repeated heterochromatic DNA. To our knowledge, this is the first demonstration in primate cells of differential repair of cellular DNA sequences

  17. A general approach to total repair cost limit replacement policies

    Directory of Open Access Journals (Sweden)

    F. Beichelt

    2014-01-01

    Full Text Available A common replacement policy for technical systems consists in replacing a system by a new one after its economic lifetime, i.e. at that moment when its long-run maintenance cost rate is minimal. However, the strict application of the economic lifetime does not take into account the individual deviations of maintenance cost rates of single systems from the average cost development. Hence, Beichet proposed the total repair cost limit replacement policy: the system is replaced by a new one as soon as its total repair cost reaches or exceeds a given level. He modelled the repair cost development by functions of the Wiener process with drift. Here the same policy is considered under the assumption that the one-dimensional probability distribution of the process describing the repair cost development is given. In the examples analysed, applying the total repair cost limit replacement policy instead of the economic life-time leads to cost savings of between 4% and 30%. Finally, it is illustrated how to include the reliability aspect into the policy.

  18. 'Regular' and 'emergency' repair

    International Nuclear Information System (INIS)

    Luchnik, N.V.

    1975-01-01

    Experiments on the combined action of radiation and a DNA inhibitor using Crepis roots and on split-dose irradiation of human lymphocytes lead to the conclusion that there are two types of repair. The 'regular' repair takes place twice in each mitotic cycle and ensures the maintenance of genetic stability. The 'emergency' repair is induced at all stages of the mitotic cycle by high levels of injury. (author)

  19. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair.

    Science.gov (United States)

    Burkhart, Stephen S; Adams, Christopher R; Burkhart, Sarah S; Schoolfield, John D

    2009-03-01

    The purpose of this study was to compare the biomechanical fixation parameters of a standard double-row rotator cuff repair with those of a knotless footprint reconstruction using the double-row SwiveLock-FiberChain technique (Arthrex, Naples, FL). Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 48 +/- 10.3 years). A shoulder from each matched pair was randomly selected to receive a standard 4-anchor double-row repair of the supraspinatus tendon, and the contralateral shoulder received a 4-anchor double-row SwiveLock-FiberChain repair. The tendon was cycled from 10 N to 100 N at 1 Hz for 500 cycles, followed by a single-cycle pull to failure at 33 mm/s. Yield load, ultimate load, cyclic displacement, and mode of failure were recorded. Yield load and ultimate load were higher for the SwiveLock-FiberChain repair compared with the standard double-row repair for 6 of the 7 treatment pairs; however, 1 cadaver had a contrary outcome, so the overall mean differences in yield load and ultimate load were not significantly different from 0 by Student t test (P > .15). Furthermore, smaller differences between yield load and ultimate load for the SwiveLock-FiberChain repair in 5 of the 7 treatment pairs showed a self-reinforcing mechanism. Double-row footprint reconstruction with the knotless SwiveLock-FiberChain system in this study had yield loads, ultimate loads, and cyclic displacements that were statistically equivalent to those of standard double-row rotation cuff reconstructions. The SwiveLock-FiberChain system's combination of strength, self-reinforcement, and decreased operating time may offer advantages to the surgeon, particularly when dealing with older patients in whom poor tissue quality and total operative time are important considerations.

  20. Worldwide CO2 emissions 2014. Shimmer of hope to turnaround reinforce - but no all-clear signal

    International Nuclear Information System (INIS)

    Ziesing, Hans-Joachim

    2015-01-01

    In 2014, global CO 2 emissions increase according to initial calculations by 0.5%. Apart from the two crisis years 2008/2009 was the weakest increase since the beginning of the century. As a result, CO 2 emissions reached about 32.6 billion tonnes a new climax. A turnaround this is not yet, but the CO 2 emissions in many countries, particularly in industrialized countries declined. Thus, the CO 2 emissions have declined in the Annex I countries overall by 1.8%. For this particular contributed the development in the EU, in almost without exception, all Member States have experienced an emission reduction. Of the major countries, this also applies to the Ukraine, Japan, Russia and Australia. In contrast, there was an increase in the US, although this turned out very moderate with an increase of just under 1%. If the global CO 2 emissions have increased despite the decline in the group of Annex I countries again, this is primarily a result of the increase in developing countries. Here, CO 2 emissions were by around the year 2014 415 million tons or 2.4% higher than 2013. Since 2008, China occupied top position ahead of the US in 2014 was not expanded because for many years here was the increase for the first time below 1%. By contrast, CO 2 emissions increased significantly in India by approx. 8% and in Brazil as in the Middle East by about 4%. [de

  1. When is cartilage repair successful?

    International Nuclear Information System (INIS)

    Raudner, M.; Roehrich, S.; Zalaudek, M.; Trattnig, S.; Schreiner, M.M.

    2017-01-01

    Focal cartilage lesions are a cause of long-term disability and morbidity. After cartilage repair, it is crucial to evaluate long-term progression or failure in a reproducible, standardized manner. This article provides an overview of the different cartilage repair procedures and important characteristics to look for in cartilage repair imaging. Specifics and pitfalls are pointed out alongside general aspects. After successful cartilage repair, a complete, but not hypertrophic filling of the defect is the primary criterion of treatment success. The repair tissue should also be completely integrated to the surrounding native cartilage. After some months, the transplants signal should be isointense compared to native cartilage. Complications like osteophytes, subchondral defects, cysts, adhesion and chronic bone marrow edema or joint effusion are common and have to be observed via follow-up. Radiological evaluation and interpretation of postoperative changes should always take the repair method into account. (orig.) [de

  2. Inducible repair and the two forms of tumour hypoxia - time for a paradigm shift

    International Nuclear Information System (INIS)

    Denekamp, J.; Dasu, A.

    1999-01-01

    Clinical experience shows that there is a therapeutic window between 60 and 70 Gy where many tumours are eradicated, but the function of the adjacent normal tissues is preserved. This implies much more cell kill in the tumour than is acceptable in the normal tissue. An SF 2 of 0.5 or lower is needed to account for the eradication of all tumour cells, while an SF 2 of 0.8 or higher is needed to explain why these doses are tolerated by normal tissues. No such systematic difference is known between the intrinsic sensitivity of well-oxygenated normal and tumour cells. The presence of radioresistant hypoxic cells in tumours makes it even more difficult to understand the clinical success. However, there is experimental evidence that starved cells lose their repair competence as a result of the depletion of cellular energy charge. MRS studies have shown that low ATP levels are a characteristic feature of solid tumours in rodents and man. In this paper we incorporate the concept of repair incompetence in starving, chronically hypoxic cells. The increased sensitivity of such cells has been derived from an analysis of mammalian cell lines showing inducible repair. It is proportional to the SF 2 and highest in resistant cells. The distinction between acutely hypoxic radioresistant cells and chronically hypoxic radiosensitive cells provides the key to the realistic modelling of successful radiotherapy. It also opens new conceptual approaches to radiotherapy. We conclude that it is essential to distinguish between these two kinds of hypoxic cells in predictive assays and models. (orig.)

  3. Two Ports Laparoscopic Inguinal Hernia Repair in Children

    Directory of Open Access Journals (Sweden)

    Medhat M. Ibrahim

    2015-01-01

    Full Text Available Introduction. Several laparoscopic treatment techniques were designed for improving the outcome over the last decade. The various techniques differ in their approach to the inguinal internal ring, suturing and knotting techniques, number of ports used in the procedures, and mode of dissection of the hernia sac. Patients and Surgical Technique. 90 children were subjected to surgery and they undergone two-port laparoscopic repair of inguinal hernia in children. Technique feasibility in relation to other modalities of repair was the aim of this work. 90 children including 75 males and 15 females underwent surgery. Hernia in 55 cases was right-sided and in 15 left-sided. Two patients had recurrent hernia following open hernia repair. 70 (77.7% cases were suffering unilateral hernia and 20 (22.2% patients had bilateral hernia. Out of the 20 cases 5 cases were diagnosed by laparoscope (25%. The patients’ median age was 18 months. The mean operative time for unilateral repairs was 15 to 20 minutes and bilateral was 21 to 30 minutes. There was no conversion. The complications were as follows: one case was recurrent right inguinal hernia and the second was stitch sinus. Discussion. The results confirm the safety and efficacy of two ports laparoscopic hernia repair in congenital inguinal hernia in relation to other modalities of treatment.

  4. Betonreparationers holdbarhed (Durability of Concrete Repairs)

    DEFF Research Database (Denmark)

    Brimnes, Eydbjørn; Dali, Bogi í; Larsen, Erik Stoklund

    1999-01-01

    Concrete repairs on 11 pillars on bridges built in the sixties and repaired 8 to 9 years ago have been examined. Especially the chloride penetration in the repair concrete have been measured. Chloride penetration in the repair concrete is much lower than in the original concrete....

  5. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  6. Evidence-based outcomes following inferior alveolar and lingual nerve injury and repair: a systematic review.

    Science.gov (United States)

    Kushnerev, E; Yates, J M

    2015-10-01

    The inferior alveolar nerve (IAN) and lingual (LN) are susceptible to iatrogenic surgical damage. Systematically review recent clinical evidence regarding IAN/LN repair methods and to develop updated guidelines for managing injury. Recent publications on IAN/LN microsurgical repair from Medline, Embase and Cochrane Library databases were screened by title/abstract. Main texts were appraised for exclusion criteria: no treatment performed or results provided, poor/lacking procedural description, cohort nerve recovery occurred after direct apposition and suturing if nerve ending gaps were nerve grafting (sural/greater auricular nerve). Timing of microneurosurgical repair after injury remains debated. Most authors recommend surgery when neurosensory deficit shows no improvement 90 days post-diagnosis. Nerve transection diagnosed intra-operatively should be repaired in situ; minor nerve injury repair can be delayed. No consensus exists regarding optimal methods and timing for IAN/LN repair. We suggest a schematic guideline for treating IAN/LN injury, based on the most current evidence. We acknowledge that additional RCTs are required to provide definitive confirmation of optimal treatment approaches. © 2015 John Wiley & Sons Ltd.

  7. Improving Emergency Department radiology transportation time: a successful implementation of lean methodology.

    Science.gov (United States)

    Hitti, Eveline A; El-Eid, Ghada R; Tamim, Hani; Saleh, Rana; Saliba, Miriam; Naffaa, Lena

    2017-09-05

    Emergency Department overcrowding has become a global problem and a growing safety and quality concern. Radiology and laboratory turnaround time, ED boarding and increased ED visits are some of the factors that contribute to ED overcrowding. Lean methods have been used in the ED to address multiple flow challenges from improving door-to-doctor time to reducing length of stay. The objective of this study is to determine the effectiveness of using Lean management methods on improving Emergency Department transportation times for plain radiography. We performed a before and after study at an academic urban Emergency Department with 49,000 annual visits after implementing a Lean driven intervention. The primary outcome was mean radiology transportation turnaround time (TAT). Secondary outcomes included overall study turnaround time from order processing to preliminary report time as well as ED length of stay. All ED patients undergoing plain radiography 6 months pre-intervention were compared to all ED patients undergoing plain radiography 6 months post-intervention after a 1 month washout period. Post intervention there was a statistically significant decrease in the mean transportation TAT (mean ± SD: 9.87 min ± 15.05 versus 22.89 min ± 22.05, respectively, p-value <0.0001). In addition, it was found that 71.6% of patients in the post-intervention had transportation TAT ≤ 10 min, as compared to 32.3% in the pre-intervention period, p-value <0.0001, with narrower interquartile ranges in the post-intervention period. Similarly, the "study processing to preliminary report time" and the length of stay were lower in the post-intervention as compared to the pre-intervention, (52.50 min ± 35.43 versus 54.04 min ± 34.72, p-value = 0.02 and 3.65 h ± 5.17 versus 4.57 h ± 10.43, p < 0.0001, respectively), in spite of an increase in the time it took to elease a preliminary report in the post-intervention period. Using Lean change management

  8. Residual stress by repair welds

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Toyoda, Masao

    2003-01-01

    Residual stress by repair welds is computed using the thermal elastic-plastic analysis with phase-transformation effect. Coupling phenomena of temperature, microstructure, and stress-strain fields are simulated in the finite-element analysis. Weld bond of a plate butt-welded joint is gouged and then deposited by weld metal in repair process. Heat source is synchronously moved with the deposition of the finite-element as the weld deposition. Microstructure is considered by using CCT diagram and the transformation behavior in the repair weld is also simulated. The effects of initial stress, heat input, and weld length on residual stress distribution are studied from the organic results of numerical analysis. Initial residual stress before repair weld has no influence on the residual stress after repair treatment near weld metal, because the initial stress near weld metal releases due to high temperature of repair weld and then stress by repair weld regenerates. Heat input has an effect for residual stress distribution, for not its magnitude but distribution zone. Weld length should be considered reducing the magnitude of residual stress in the edge of weld bead; short bead induces high tensile residual stress. (author)

  9. Chromosome End Repair and Genome Stability in Plasmodium falciparum.

    Science.gov (United States)

    Calhoun, Susannah F; Reed, Jake; Alexander, Noah; Mason, Christopher E; Deitsch, Kirk W; Kirkman, Laura A

    2017-08-08

    The human malaria parasite Plasmodium falciparum replicates within circulating red blood cells, where it is subjected to conditions that frequently cause DNA damage. The repair of DNA double-stranded breaks (DSBs) is thought to rely almost exclusively on homologous recombination (HR), due to a lack of efficient nonhomologous end joining. However, given that the parasite is haploid during this stage of its life cycle, the mechanisms involved in maintaining genome stability are poorly understood. Of particular interest are the subtelomeric regions of the chromosomes, which contain the majority of the multicopy variant antigen-encoding genes responsible for virulence and disease severity. Here, we show that parasites utilize a competitive balance between de novo telomere addition, also called "telomere healing," and HR to stabilize chromosome ends. Products of both repair pathways were observed in response to DSBs that occurred spontaneously during routine in vitro culture or resulted from experimentally induced DSBs, demonstrating that both pathways are active in repairing DSBs within subtelomeric regions and that the pathway utilized was determined by the DNA sequences immediately surrounding the break. In combination, these two repair pathways enable parasites to efficiently maintain chromosome stability while also contributing to the generation of genetic diversity. IMPORTANCE Malaria is a major global health threat, causing approximately 430,000 deaths annually. This mosquito-transmitted disease is caused by Plasmodium parasites, with infection with the species Plasmodium falciparum being the most lethal. Mechanisms underlying DNA repair and maintenance of genome integrity in P. falciparum are not well understood and represent a gap in our understanding of how parasites survive the hostile environment of their vertebrate and insect hosts. Our work examines DNA repair in real time by using single-molecule real-time (SMRT) sequencing focused on the subtelomeric

  10. Mechanical characterization of composite repairs for fiberglass wind turbine blades

    Science.gov (United States)

    Chawla, Tanveer Singh

    While in service, wind turbine blades experience various modes of loading. An example is impact loading in the form of hail or bird strikes, which might lead to localized damage or formation of cracks a few plies deep on the blade surface. One of the methods to conduct repairs on wind turbine blades that are damaged while in service is hand lay-up of the repair part after grinding out the damaged portion and some of its surrounding area. The resin used for such repairs usually differs from the parent plate resin in composition and properties such as gel time, viscosity, etc. As a result the properties of the repaired parts are not the same as that of the undamaged blades. Subsequent repetitive loading can be detrimental to weak repairs to such an extent so as to cause delamination at the parent-repair bondline causing the repairs to eventually fall off the blade. Thus the strength and toughness of the repair are of critical importance. Initial part of this work consists of an effort to increase repair strength by identifying an optimum hand layup repair resin for fiberglass wind turbine blades currently being manufactured by a global company. As delamination of the repair from the parent blade is a major concern and unidirectional glass fibers along with a polymer resin are used to manufacture blades under consideration, testing method detailed in ASTM D 5528 (Test Method for Mode I Interlaminar Fracture Toughness of Unidirectional Fiber-Reinforced Polymer Matrix Composites) was followed to determine propagation fracture toughness values of the prospective vinyl ester repair resin candidates. These values were compared to those for a base polyester repair resin used by the company. Experimental procedure and results obtained from the above mentioned testing using double cantilever beam (DCB) specimens are detailed. Three new repair resins were shortlisted through mode I testing. It was also found that variation in the depth of the ground top ply of the parent part

  11. Total Extraperitoneal Hernia Repair: Residency Teaching Program and Outcome Evaluation.

    Science.gov (United States)

    Garofalo, Fabio; Mota-Moya, Pau; Munday, Andrew; Romy, Sébastien

    2017-01-01

    Total extraperitoneal (TEP) hernia repair has been shown to offer less pain, shorter postoperative hospital stay and earlier return to work when compared to open surgery. Our institution routinely performs TEP procedures for patients with primary or recurrent inguinal hernias. The aim of this study was to show that supervised senior residents can safely perform TEP repairs in a teaching setting. All consecutive patients treated for inguinal hernias by laparoscopic approach from October 2008 to June 2012 were retrospectively analyzed from a prospective database. A total of 219 TEP repairs were performed on 171 patients: 123 unilateral and 48 bilateral. The mean patient age was 51.6 years with a standard deviation (SD) of ± 15.9. Supervised senior residents performed 171 (78 %) and staff surgeons 48 (22 %) TEP repairs, respectively. Thirty-day morbidity included cases of inguinal paresthesias (0.4 %, n = 1), umbilical hematomas (0.9 %, n = 2), superficial wound infections (0.9 %, n = 2), scrotal hematomas (2.7 %, n = 6), postoperative urinary retentions (2.7 %, n = 6), chronic pain syndromes (5 %, n = 11) and postoperative seromas (6.7 %, n = 14). Overall, complication rates were 18.7 % for staff surgeons and 19.3 % for residents (p = 0.83). For staff surgeons and residents, mean operative times for unilateral hernia repairs were 65 min (SD ± 18.9) and 77.6 min (SD ± 29.8) (p = 0.043), respectively, while mean operative times for bilateral repairs were 115 min (SD ± 40.1) and 103.6 (SD ± 25.9) (p = 0.05). TEP repair is a safe procedure when performed by supervised senior surgical trainees. Teaching of TEP should be routinely included in general surgery residency programs.

  12. A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

    Science.gov (United States)

    Ramappa, Arun J; Chen, Alvin; Hertz, Benjamin; Wexler, Michael; Grimaldi Bournissaint, Leandro; DeAngelis, Joseph P; Nazarian, Ara

    2014-01-01

    Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. Controlled laboratory study. Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.

  13. The journey of DNA repair.

    Science.gov (United States)

    Saini, Natalie

    2015-12-01

    21 years ago, the DNA Repair Enzyme was declared "Molecule of the Year". Today, we are celebrating another "year of repair", with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  14. Remote repair robots for dissolvers in nuclear fuel reprocessing plants

    International Nuclear Information System (INIS)

    Sugiyama, Sen; Hirose, Yasuo; Kawamura, Hironobu; Minato, Akira; Ozaki, Norihiko.

    1984-01-01

    In nuclear facilities, for the purpose of the reduction of radiation exposure of workers, the shortening of working time and the improvement of capacity ratio of the facilities, the technical development of various devices for remote maintenance and inspection has been advanced so far. This time, an occasion came to inspect and repair the pinhole defects occurred in spent fuel dissolving tanks in the reprocessing plant of Tokai Establishment, Power Reactor and Nuclear Fuel Development Corp. However, since the radiation environmental condition and the restricting condition due to the object of repair were extremely severe, it was impossible to cope with them using conventional robot techniques. Consequently, a repair robot withstanding high level radiation has been developed anew, which can work by totally remote operation in the space of about 270 mm inside diameter and about 6 m length. The repair robot comprises a periscope reflecting mirror system, a combined underwater and atmospheric use television, a grinder, a welder, a liquid penetrant tester and an ultrasonic flaw detector. The key points of the development were the parts withstanding high level radiation and the selection of materials, to make the mechanism small size and the realization of totally remote operation. (Kako, I.)

  15. Thymus repair compared with hemopoiesis repair in spleen after protracted irradiation

    International Nuclear Information System (INIS)

    Mackova, N.

    1987-01-01

    Matured female mice of ICR strain were irradiated from a 60 Co source with a daily dose rate of 5 Gy till total accumulated dose of 10 Gy for 2 days. Animals were examined in various intervals within 42 days after irradiation. The results revealed that protracted irradiation will induce a massive injury to hemopoiesis. The first repair processes occurred in thymus and were characterized by two phases. The first repair wave peaked about the day 10 and the second about the day 30 after irradiation. The repair processes observed in the red pulp of the spleen reached their highest intensity approximately between the days 14-16 after irradiation. (author)

  16. Detection of Repair of the Zone of Calcified Cartilage with Osteoarthritis through Mesenchymal Stem Cells by Ultrashort Echo Time Magnetic Resonance Imaging.

    Science.gov (United States)

    Zhou, Quan; Li, Shao-Lin; Ma, Ya-Jun; de Tal, Vicki; Li, Wei; Zhao, Ying-Hua

    2018-05-05

    Currently, magnetic resonance imaging (MRI) is the most commonly used imaging modality for observing the growth and development of mesenchymal stem cells (MSCs) after in vivo transplantation to treat osteoarthritis (OA). However, it is a challenge to accurately monitor the treatment effects of MSCs in the zone of calcified cartilage (ZCC) with OA. This is especially true in the physiological and biochemical views that are not accurately detected by MRI contrast agents. In contrast, ultrashort time echo (UTE) MRI has been shown to be sensitive to the presence of the ZCC, creating the potential for more effectively observing the repair of the ZCC in OA by MSCs. A special focus is given to the outlook of the use of UTE MRI to detect repair of the ZCC with OA through MSCs. The limitations of the current techniques for clinical applications and future directions are also discussed. Using the combined keywords: "osteoarthritis", "mesenchymal stem cells", "calcified cartilage", and "magnetic resonance imaging", the PubMed/MEDLINE literature search was conducted up to June 1, 2017. A total of 132 published articles were initially identified citations. Of the 132 articles, 48 articles were selected after further detailed review. This study referred to all the important English literature in full. In contrast, UTE MRI has been shown to be sensitive to the presence of the ZCC, creating the potential for more effectively observing the repair of the ZCC in OA by MSCs. The current studies showed that the ZCC could be described in terms of its histomorphology and biochemistry by UTE MRI. We prospected that UTE MRI has been shown the potential for more effectively observing the repair of the ZCC in OA by MSCs in vivo.

  17. Simple repair approach for mitral regurgitation in Barlow disease.

    Science.gov (United States)

    Ben Zekry, Sagit; Spiegelstein, Dan; Sternik, Leonid; Lev, Innon; Kogan, Alexander; Kuperstein, Rafael; Raanani, Ehud

    2015-11-01

    Mitral valve repair for myxomatous Barlow disease is a challenging procedure requiring complex surgery with less than optimal results. The use of ring-only repair has been previously reported but never analyzed or followed-up. We investigated this simple valve repair approach for patients with Barlow disease and multisegment involvement causing mainly central jet. Of 572 patients who underwent mitral valve repair for mitral regurgitation at our medical center, 24 with Barlow disease (aged 47 ± 14 years; 46% male) underwent ring-only repair. Patients were characterized by severely enlarged mitral valve annulus, multisegment prolapse involving both leaflets, and demonstrated mainly a central wide regurgitant jet. Surgical technique included only the implantation of a large mitral annuloplasty ring. Early and late outcome results were compared with those of the remaining patients who underwent conventional mitral valve repair for degenerative disease (controls). All ring-only patients presented with moderate-severe/severe mitral regurgitation (vena contracta, 0.6 ± 0.1 cm; regurgitation volume, 52 ± 17 mL), with mainly a central jet and almost preserved ejection fraction (59% ± 6%). Cardiopulmonary bypass and crossclamp times were significantly shorter compared with controls (P Barlow disease patients with multisegment involvement and mainly central regurgitant jet is both simple and reproducible with excellent late outcomes. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Prognostic factors in sensory recovery after digital nerve repair.

    Science.gov (United States)

    Bulut, Tuğrul; Akgün, Ulaş; Çıtlak, Atilla; Aslan, Cihan; Şener, Ufuk; Şener, Muhittin

    2016-01-01

    The prognostic factors that affect sensory nerve recovery after digital nerve repair are variable because of nonhomogeneous data, subjective tests, and different assessment/scoring methods. The aim of this study was to evaluate the success of sensory nerve recovery after digital nerve repair and to investigate the prognostic factors in sensorial healing. Ninety-six digital nerve repairs of 63 patients were retrospectively evaluated. All nerves were repaired with end-to-end neurorraphy. The static two-point discrimination (s2PD) and Semmes Weinstein monofilament (SWM) tests were performed to evaluate sensory recovery. The association between prognostic factors such as gender, age, involved digit, time from injury to repair, length of follow-up, smoking, concomitant injuries, type of injury, and sensory recovery results were assessed. The s2PD test demonstrated excellent results in 26 nerves (27%), good results in 61 nerves (64%), and poor results in 9 nerves (9%). The results of the SWM test according to Imai classification showed that 31 nerves (32%) were normal, light touch was diminished in 38 nerves (40%), protective sensation was diminished in 17 nerves (18%), loss of protective sensation occurred in 5 nerves (5%), and 5 nerves (5%) were anesthetic. There was a negative relationship between age, smoking, concomitant injuries, and sensory recovery. Our results demonstrate that concomitant tendon, bone and vascular injuries, older age, and smoking were associated with worse sensory nerve recovery results. However, all digital nerve injuries should be repaired, regardless of these prognostic factors.

  19. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15 calendar...

  20. Introduction of a New Suture Method in Repair of Peripheral Nerves Injured with a Sharp Mechanism

    Directory of Open Access Journals (Sweden)

    Alireza Saied

    2015-09-01

    Full Text Available Background: The standard method for repair of an injured peripheal nerve is epineural repair with separate sutures. Herein we describe a method in which the nerve is sutured with continous sutures. In fact this method has not been utilized for nerve repair previously and our purpose was to compare it to the standard method. If it proved to be successful it would replace the standard method in certain circumstances. Methods: The proposal of the clinical trial was given a reference number form the ethics comitee. 25 dogs in which the scaitic nerve was cut by a sharp blade under genaeral anesthesia were divided randomly into three groups: control (5 dogs, repair of sciatic nerve with simple sutures (10 and repair with continous sutures (10. In the control group the nerve was not repaired at all. After 6 weeks the dogs were killed and the nerve was studied by light and electronic microscopes. The amount of consumed suture material, time of repair, myelin thickness and axon diiameter were examined. Ultrastructural studies were performed to assess degeneration and regeneration findings. Results: Time of repair and the amount of consumed suture material were significantly lower in the continous group (P

  1. Evaluation of Repair Tension in Arthroscopic Rotator Cuff Repair: Does It Really Matter to the Integrity of the Rotator Cuff?

    Science.gov (United States)

    Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon

    2016-11-01

    Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016

  2. Transaortic Alfieri Edge-to-Edge Repair for Functional Mitral Regurgitation.

    Science.gov (United States)

    Imasaka, Ken-Ichi; Tayama, Eiki; Morita, Shigeki; Toriya, Ryohei; Tomita, Yukihiro

    2018-03-01

    There is controversy about handling functional mitral regurgitation in patients undergoing aortic valve or proximal aortic operations. We describe a transaortic Alfieri edge-to-edge repair for functional mitral regurgitation that reduces operative excessive invasion and prolonged cardiopulmonary bypass time. Between May 2013 and December 2016, 10 patients underwent transaortic Alfieri edge-to-edge mitral repair. There were no operative deaths. The severity of mitral regurgitation immediately after the operation by transesophageal echocardiography was none or trivial in all patients. A transaortic Alfieri edge-to-edge repair for functional mitral regurgitation is a simple and safe approach. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected no later than 15 calendar days after it is detected, except as...

  4. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it is...

  5. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    Science.gov (United States)

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  6. Beyond repair foci: DNA double-strand break repair in euchromatic and heterochromatic compartments analyzed by transmission electron microscopy.

    Directory of Open Access Journals (Sweden)

    Yvonne Lorat

    Full Text Available DNA double-strand breaks (DSBs generated by ionizing radiation pose a serious threat to the preservation of genetic and epigenetic information. The known importance of local chromatin configuration in DSB repair raises the question of whether breaks in different chromatin environments are recognized and repaired by the same repair machinery and with similar efficiency. An essential step in DSB processing by non-homologous end joining is the high-affinity binding of Ku70-Ku80 and DNA-PKcs to double-stranded DNA ends that holds the ends in physical proximity for subsequent repair.Using transmission electron microscopy to localize gold-labeled pKu70 and pDNA-PKcs within nuclear ultrastructure, we monitored the formation and repair of actual DSBs within euchromatin (electron-lucent and heterochromatin (electron-dense in cortical neurons of irradiated mouse brain.While DNA lesions in euchromatin (characterized by two pKu70-gold beads, reflecting the Ku70-Ku80 heterodimer are promptly sensed and rejoined, DNA packaging in heterochromatin appears to retard DSB processing, due to the time needed to unravel higher-order chromatin structures. Complex pKu70-clusters formed in heterochromatin (consisting of 4 or ≥ 6 gold beads may represent multiple breaks in close proximity caused by ionizing radiation of highly-compacted DNA. All pKu70-clusters disappeared within 72 hours post-irradiation, indicating efficient DSB rejoining. However, persistent 53BP1 clusters in heterochromatin (comprising ≥ 10 gold beads, occasionally co-localizing with γH2AX, but not pKu70 or pDNA-PKcs, may reflect incomplete or incorrect restoration of chromatin structure rather than persistently unrepaired DNA damage.Higher-order organization of chromatin determines the accessibility of DNA lesions to repair complexes, defining how readily DSBs are detected and processed. DNA lesions in heterochromatin appear to be more complex, with multiple breaks in spatial vicinity inducing

  7. Use of mobile phones and text messaging to decrease the turnaround time for early infant HIV diagnosis and notification in rural Zambia: an observational study.

    Science.gov (United States)

    Sutcliffe, Catherine G; Thuma, Philip E; van Dijk, Janneke H; Sinywimaanzi, Kathy; Mweetwa, Sydney; Hamahuwa, Mutinta; Moss, William J

    2017-03-08

    Early infant diagnosis of HIV infection is challenging in rural sub-Saharan Africa as blood samples are sent to central laboratories for HIV DNA testing, leading to delays in diagnosis and treatment initiation. Simple technologies to rapidly deliver results to clinics and notify mothers of test results would decrease many of these delays. The feasibility of using mobile phones to contact mothers was evaluated. In addition, the first two years of implementation of a national short message service (SMS) reporting system to deliver test results from the laboratory to the clinic were evaluated. The study was conducted in Macha, Zambia from 2013 to 2015 among mothers of HIV-exposed infants. Mothers were interviewed about mobile phone use and willingness to be contacted directly or through their rural health center. Mothers were contacted according to their preferred method of communication when test results were available. Mothers of positive infants were asked to return to the clinic as soon as possible. Dates of sample collection, delivery of test results to the clinic and notification of mothers were documented in addition to test results. Four hundred nineteen mothers and infants were enrolled. Only 30% of mothers had ever used a mobile phone. 96% of mobile phone owners were reached by study staff and 98% of mothers without mobile phones were contacted through their rural health center. Turnaround times for mothers of positive infants were approximately 2 weeks shorter than for mothers of negative infants. Delivery of test results by the national SMS system improved from 2013 to 2014, with increases in the availability of texted results (38 vs. 91%) and arrival of the texted result prior to the hardcopy report (27 vs. 83%). Texted results arriving at the clinic before the hardcopy were received a median of 19 days earlier. Four discrepancies between texted and hardcopy results were identified out of 340 tests. Mobile phone and text messaging technology has the

  8. Clinical value of Tei index in pediatric patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Song, Bing; Qi, Quan; Liu, Ruisheng; Xing, Wang; Tang, Hanbo; Li, Yuanmin

    2015-01-01

    Tetralogy of Fallot is a congenital heart disease characterized by underdevelopment of the right ventricular infundibulum. Present study aimed to explore the clinic value of Tei index in assessing right ventricular function of pediatric patients with repaired Tetralogy of Fallot. A total of 45 pediatric patients with repaired Tetralogy of Fallot were recruited and classified into: group A (Tei index 0.7; n=13, aging 4-14 years). The right ventricular Tei index value was related to the clinical characteristics of Tetralogy of Fallot repair patients. Right ventricular Tei index was positively correlated with ventilation time, drainage volumes, and negatively with drug assistance and Intensive Care Unit (ICU) stay, although time for drug assistance and ICU stay were not statically different between group B and group C. There was no significant difference in left ventricular ejection fraction. Tei index is a sensitive indicator of right ventricular dysfunction, and has important clinical value to better our understanding of right ventricular function after tetralogy of Fallot repair.

  9. Kinetic theory approach to modeling of cellular repair mechanisms under genome stress.

    Directory of Open Access Journals (Sweden)

    Jinpeng Qi

    Full Text Available Under acute perturbations from outer environment, a normal cell can trigger cellular self-defense mechanism in response to genome stress. To investigate the kinetics of cellular self-repair process at single cell level further, a model of DNA damage generating and repair is proposed under acute Ion Radiation (IR by using mathematical framework of kinetic theory of active particles (KTAP. Firstly, we focus on illustrating the profile of Cellular Repair System (CRS instituted by two sub-populations, each of which is made up of the active particles with different discrete states. Then, we implement the mathematical framework of cellular self-repair mechanism, and illustrate the dynamic processes of Double Strand Breaks (DSBs and Repair Protein (RP generating, DSB-protein complexes (DSBCs synthesizing, and toxins accumulating. Finally, we roughly analyze the capability of cellular self-repair mechanism, cellular activity of transferring DNA damage, and genome stability, especially the different fates of a certain cell before and after the time thresholds of IR perturbations that a cell can tolerate maximally under different IR perturbation circumstances.

  10. Kinetic theory approach to modeling of cellular repair mechanisms under genome stress.

    Science.gov (United States)

    Qi, Jinpeng; Ding, Yongsheng; Zhu, Ying; Wu, Yizhi

    2011-01-01

    Under acute perturbations from outer environment, a normal cell can trigger cellular self-defense mechanism in response to genome stress. To investigate the kinetics of cellular self-repair process at single cell level further, a model of DNA damage generating and repair is proposed under acute Ion Radiation (IR) by using mathematical framework of kinetic theory of active particles (KTAP). Firstly, we focus on illustrating the profile of Cellular Repair System (CRS) instituted by two sub-populations, each of which is made up of the active particles with different discrete states. Then, we implement the mathematical framework of cellular self-repair mechanism, and illustrate the dynamic processes of Double Strand Breaks (DSBs) and Repair Protein (RP) generating, DSB-protein complexes (DSBCs) synthesizing, and toxins accumulating. Finally, we roughly analyze the capability of cellular self-repair mechanism, cellular activity of transferring DNA damage, and genome stability, especially the different fates of a certain cell before and after the time thresholds of IR perturbations that a cell can tolerate maximally under different IR perturbation circumstances.

  11. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    Science.gov (United States)

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  12. Increased rate of repair of ultraviolet-induced DNA strand breaks in mitogen stimulated lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, S.M.; Lavin, M.F.; Jennings, P.A. (Queensland Univ., St. Lucia (Australia). Dept. of Biochemistry; Queensland Univ., St. Lucia (Australia). Dept. of Veterinary Pathology; Queensland Univ. St. Lucia (Australia). Dept. of Public Health)

    1982-05-01

    Previous results have shown that phytohaemagglutinin-stimulated bovine lymphocytes exhibit a peak of ultraviolet-induced DNA repair synthesis 3 to 4 days after addition of mitogen. The level of repair synthesis was approximately tenfold higher than that in unstimulated lymphocytes. These studies have been extended to examine the rate of repair of strand breaks in U.V.-irradiated bovine lymphocytes. The extent of breakage of DNA was shown to be the same in mitogen-stimulated and unstimulated lymphocytes from two breeds of cattle, when determined by sedimentation of nucleoids on sucrose gradients. However, in mitogen-stimulated cells the time taken to repair DNA strand breaks was 6 hours compared with 12 hours in stationary phase lymphocytes after a U.V. dose of 5 J/m/sup 2/. These results suggest that the increased rate of repair of strand breaks is due to the induction of enzymes involved at the post-incision stage of DNA repair. Thus the increased level of repair synthesis observed in earlier work correlates with an increased rate of repair of DNA strand breaks in phytohaemagglutinin-stimulated bovine lymphocytes.

  13. Increased rate of repair of ultraviolet-induced DNA strand breaks in mitogen stimulated lymphocytes

    International Nuclear Information System (INIS)

    Hamlet, S.M.; Lavin, M.F.; Jennings, P.A.; Queensland Univ., St. Lucia; Queensland Univ. St. Lucia

    1982-01-01

    Previous results have shown that phytohaemagglutinin-stimulated bovine lymphocytes exhibit a peak of ultraviolet-induced DNA repair synthesis 3 to 4 days after addition of mitogen. The level of repair synthesis was approximately tenfold higher than that in unstimulated lymphocytes. These studies have been extended to examine the rate of repair of strand breaks in U.V.-irradiated bovine lymphocytes. The extent of breakage of DNA was shown to be the same in mitogen-stimulated and unstimulated lymphocytes from two breeds of cattle, when determined by sedimentation of nucleoids on sucrose gradients. However, in mitogen-stimulated cells the time taken to repair DNA strand breaks was 6 hours compared with 12 hours in stationary phase lymphocytes after a U.V. dose of 5 J/m 2 . These results suggest that the increased rate of repair of strand breaks is due to the induction of enzymes involved at the post-incision stage of DNA repair. Thus the increased level of repair synthesis observed in earlier work correlates with an increased rate of repair of DNA strand breaks in phytohaemagglutinin-stimulated bovine lymphocytes. (author)

  14. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Ultee, Klaas H J; Hurks, Rob; Buck, Dominique B.; Dasilva, George S.; Soden, Peter A.; Van Herwaarden, Joost A.; Verhagen, Hence J M; Schermerhorn, Marc L.

    2015-01-01

    Background Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion of AAA

  15. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    K.H.J. Ultee (Klaas); R. Hurks (Rob); D.B. Buck (Dominique B.); G.S. Dasilva (George S.); P.A. Soden (Peter A.); J.A. van Herwaarden (Joost); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2015-01-01

    textabstractBackground Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion

  16. Treatment and Controversies in Paraesophageal Hernia Repair

    Directory of Open Access Journals (Sweden)

    P. Marco eFisichella

    2015-04-01

    Full Text Available Background: Historically all paraesophageal hernias were repaired surgically, today intervention is reserved for symptomatic paraesophageal hernias. In this review, we describe the indications for repair and explore the controversies in paraesophageal hernia repair, which include a comparison of open to laparoscopic paraesophageal hernia repair, the necessity of complete sac excision, the routine performance of fundoplication, and the use of mesh for hernia repair.Methods: We searched Pubmed for papers published between 1980 and 2015 using the following keywords: hiatal hernias, paraesophageal hernias, regurgitation, dysphagia, gastroesophageal reflux disease, aspiration, GERD, endoscopy, manometry, pH monitoring, proton pump inhibitors, anemia, iron deficiency anemia, Nissen fundoplication, sac excision, mesh, mesh repair. Results: Indications for paraesophageal hernia repair have changed, and currently symptomatic paraesophageal hernias are recommended for repair. In addition, it is important not to overlook iron-deficiency anemia and pulmonary complaints, which tend to improve with repair. Current practice favors a laparoscopic approach, complete sac excision, primary crural repair with or without use of mesh, and a routine fundoplication.

  17. Double-Strand DNA Break Repair in Mycobacteria.

    Science.gov (United States)

    Glickman, Michael S

    2014-10-01

    Discontinuity of both strands of the chromosome is a lethal event in all living organisms because it compromises chromosome replication. As such, a diversity of DNA repair systems has evolved to repair double-strand DNA breaks (DSBs). In part, this diversity of DSB repair systems has evolved to repair breaks that arise in diverse physiologic circumstances or sequence contexts, including cellular states of nonreplication or breaks that arise between repeats. Mycobacteria elaborate a set of three genetically distinct DNA repair pathways: homologous recombination, nonhomologous end joining, and single-strand annealing. As such, mycobacterial DSB repair diverges substantially from the standard model of prokaryotic DSB repair and represents an attractive new model system. In addition, the presence in mycobacteria of a DSB repair system that can repair DSBs in nonreplicating cells (nonhomologous end joining) or when DSBs arise between repeats (single-strand annealing) has clear potential relevance to Mycobacterium tuberculosis pathogenesis, although the exact role of these systems in M. tuberculosis pathogenesis is still being elucidated. In this article we will review the genetics of mycobacterial DSB repair systems, focusing on recent insights.

  18. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  19. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  20. Analysis of Repairable Geo/G/1 Queues with Negative Customers

    Directory of Open Access Journals (Sweden)

    Doo Ho Lee

    2014-01-01

    Full Text Available We consider discrete-time Geo/G/1 queues with negative customers and a repairable server. The server is subject to failure due to a negative customer arrival. As soon as a negative customer arrives at a system, the server fails and one positive (ordinary customer is forced to leave. At a failure instant, the server is turned off and the repair process immediately begins. We construct the mathematical model and present the probability generating functions of the system size distribution and the FCFS sojourn time distribution. Finally, some numerical examples are given to show the influence of negative customer arrival on the performance measures of the system.

  1. Residual life assessment of the SSME/ATD HPOTP turnaround duct (TAD)

    Science.gov (United States)

    Gross, R. Steven

    1996-01-01

    This paper is concerned with the prediction of the low cycle thermal fatigue behavior of a component in a developmental (ATD) high pressure liquid oxygen turbopump (HPOTP) for the Space Shuttle Main Engine (SSME). This component is called the Turnaround Duct (TAD). The TAD is a complex single piece casting of MAR-M-247 material. Its function is to turn the hot turbine exhaust gas (1200 F hydrogen rich gas steam) such that it can exhaust radially out of the turbopump. In very simple terms, the TAD consists of two rings connected axially by 22 hollow airfoil shaped struts with the turning vanes placed at the top, middle, and bottom of each strut. The TAD is attached to the other components of the pump via bolts passing through 14 of the 22 struts. Of the remaining 8 struts, four are equally spaced (90 deg interval) and containing a cooling tube through which liquid hydrogen passes on its way to cool the shaft bearing assemblies. The remaining 4 struts are empty. One of the pump units in the certification test series was destructively examined after 22 test firings. Substantial axial cracking was found in two of the struts which contain cooling tubes. None of the other 20 struts showed any sign of internal cracking. This unusual low cycle thermal fatigue behavior within the two cooling tube struts is the focus of this study.

  2. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  3. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  4. Load response and gap formation in a single-row cruciate suture rotator cuff repair.

    Science.gov (United States)

    Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C

    2017-06-01

    Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.

  5. Repair of potentially lethal damage in unfed plateau phase cultures of Ehrlich ascited tumour cells

    International Nuclear Information System (INIS)

    Illiakis, G.

    1980-01-01

    Plateau phase EAT-cells have been irradiated at different times in the plateau phase and their ability to repair PLD has been measured. A large capacity to repair PLD has been observed if the cultures were kept in the plateau phase for some hours after irradiation before diluting and plating to measure the survival. In combination with theoretical considerations it is concluded that almost all the PLD produced under these conditions can be repaired. The reaction rate of this repair was independent of the dose and the age of the culture. The results also indicate that PLD repair is independent of the intercellular contact of EAT-cells. (author)

  6. Inguinal hernia repair with tension-free hernioplasty under local anesthesia

    International Nuclear Information System (INIS)

    Gao, Jia-Sen; Wang, Zhen-Jun; Zhao, Bo; Ma Song Zhang; Pang, Guo-Yi; Na, Dong-Ming; Zhang Yu-Dong

    2009-01-01

    To evaluate the use of local anesthesia in tension-free hernioplasty in a local hospital. The study took place at Beijing Chaoyang Hospital Affiliated to Capital Medical University, Beijing, China during the period from January 2007 to May 2008. All 110 patients who had undergone inguinal hernia repair with mesh under local anesthesia were included in the study. To increase the homogeneity of the sample, we excluded umbilical hernia repairs, parastomal hernia repairs, non-elective procedures, procedures not involving mesh, and repairs performed concurrently with another surgical procedure. We performed a retrospective review of all 110 patients' data. The average operating time was 45 minutes (30-70 minutes), and the average hospital stay was 3-4 days. There was no postoperative mortality in this study. No surgical site infection occurred. Two patients (18%) that suffered from a moderate scrotal hematoma had recovered after extract injection therapy was applied. The duration of incisional pain was 2-3 days, and no patient required post-operative analgesia. During the follow-up, no recurrence occurred. The use of local anesthesia in inguinal hernia repair with tension-free hernioplasty is a safe and effective alternative for inpatient treatment. (aothor)

  7. Kinetics and capacity of repair of sublethal damage in mouse lip mucosa during fractionated irradiations

    International Nuclear Information System (INIS)

    Ang, K.K.; Xu, F.X.; Landuyt, W.; van der Schueren, E.

    1985-01-01

    The kinetics and capacity of repair of sublethal damage in mouse lip mucosa have been investigated. To assess the rate of repair 2 and 5 irradiations have been given with intervals ranging from 1 to 24 hours. It was found that the sublethal damage induced by a dose of approximately 10 Gy was fully recovered in approximately 4 hr. After a dose of 5-6 Gy, cellular repair was completed within 3 hr. The half time of repair (T1/2) was estimated to be approximately 72 min for 10 Gy and approximately 54 min for 5-6 Gy. Although these results suggest that the rate of repair is dependent on the fraction size, the possible influence of the amount of repair of sublethal radiation damage with the various fraction sizes used can not be ruled out. To evaluate the capacity of repair, a single dose, 2, 4 and 10 fractions have been given in a maximal overall time of 3 days in order to minimize the influence of repopulation. The slope of the isoeffective curve was 0.32 and the alpha/beta ratio was 8.5 Gy. This indicates that the capacity of cellular repair of lip mucosa is similar to those of other rapidly proliferating tissues but smaller than those of late responding tissues. The results of the present and other studies demonstrate that there are considerable differences in the repair characteristics between acutely and late responding tissues. These features have to be dealt with when fractionation schedules are markedly altered

  8. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  9. Both base excision repair and nucleotide excision repair in humans are influenced by nutritional factors.

    Science.gov (United States)

    Brevik, Asgeir; Karlsen, Anette; Azqueta, Amaya; Tirado, Anna Estaban; Blomhoff, Rune; Collins, Andrew

    2011-01-01

    Lack of reliable assays for DNA repair has largely prevented measurements of DNA repair from being included in human biomonitoring studies. Using newly developed modifications of the comet assay we tested whether a fruit- and antioxidant-rich plant-based intervention could affect base excision repair (BER) and nucleotide excision repair (NER) in a group of 102 male volunteers. BER and NER repair capacities were measured in lymphocytes before and after a dietary intervention lasting 8 weeks. The study had one control group, one group consuming three kiwifruits per day and one group consuming a variety of antioxidant-rich fruits and plant products in addition to their normal diet. DNA strand breaks were reduced following consumption of both kiwifruits (13%, p = 0.05) and antioxidant-rich plant products (20%, p = 0.02). Increased BER (55%, p = 0.01) and reduced NER (-39%, p plant products. Reduced NER was also observed in the kiwifruit group (-38%, p = 0.05), but BER was not affected in this group. Here we have demonstrated that DNA repair is affected by diet and that modified versions of the comet assay can be used to assess activity of different DNA repair pathways in human biomonitoring studies. Copyright © 2010 John Wiley & Sons, Ltd.

  10. Dynamic In Vivo Profiling of DNA Damage and Repair after Radiotherapy Using Canine Patients as a Model

    Directory of Open Access Journals (Sweden)

    Nadine Schulz

    2017-06-01

    Full Text Available Time resolved data of DNA damage and repair after radiotherapy elucidates the relation between damage, repair, and cell survival. While well characterized in vitro, little is known about the time-course of DNA damage response in tumors sampled from individual patients. Kinetics of DNA damage after radiotherapy was assessed in eight dogs using repeated in vivo samples of tumor and co-irradiated normal tissue analyzed with comet assay and phosphorylated H2AX (γH2AX immunohistochemistry. In vivo results were then compared (in silico with a dynamic mathematical model for DNA damage formation and repair. Maximum %DNA in tail was observed at 15–60 min after irradiation, with a rapid decrease. Time-courses of γH2AX-foci paralleled these findings with a small time delay and were not influenced by covariates. The evolutionary parameter search based on %DNA in tail revealed a good fit of the DNA repair model to in vivo data for pooled sarcoma time-courses, but fits for individual sarcoma time-courses suffer from the heterogeneous nature of the in vivo data. It was possible to follow dynamics of comet tail intensity and γH2AX-foci during a course of radiation using a minimally invasive approach. DNA repair can be quantitatively investigated as time-courses of individual patients by integrating this resulting data into a dynamic mathematical model.

  11. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  12. Energy economy in the midst of the energy turnaround. Can the existing business models survive?; Energiewirtschaft in der Energiewende. Koennen bestehende Geschaeftsmodelle ueberleben?

    Energy Technology Data Exchange (ETDEWEB)

    Adam, Rolf [EMEAR, Cisco Systems, Hallbergmoos (Germany). Energy and Smart Grid; Einhellig, Ludwig [Deloitte, Muenchen (Germany); Herzig, Andreas [Deloitte, Stuttgart (Germany)

    2012-09-15

    The energy turnaround is a veritable export hit, at least in linguistic terms. The target scenario - a greener energy supply - is widely accepted. However, only a step further even this minimal consensus begins to crumble. One gets the impression that it is not so much about bringing the target scenario to life but rather about changing as little as possible of the existing system. So what will it take to turn the transformation of Germany's energy supply system into a success? Five propositions are presented as guidelines.

  13. My journey to DNA repair.

    Science.gov (United States)

    Lindahl, Tomas

    2013-02-01

    I completed my medical studies at the Karolinska Institute in Stockholm but have always been devoted to basic research. My longstanding interest is to understand fundamental DNA repair mechanisms in the fields of cancer therapy, inherited human genetic disorders and ancient DNA. I initially measured DNA decay, including rates of base loss and cytosine deamination. I have discovered several important DNA repair proteins and determined their mechanisms of action. The discovery of uracil-DNA glycosylase defined a new category of repair enzymes with each specialized for different types of DNA damage. The base excision repair pathway was first reconstituted with human proteins in my group. Cell-free analysis for mammalian nucleotide excision repair of DNA was also developed in my laboratory. I found multiple distinct DNA ligases in mammalian cells, and led the first genetic and biochemical work on DNA ligases I, III and IV. I discovered the mammalian exonucleases DNase III (TREX1) and IV (FEN1). Interestingly, expression of TREX1 was altered in some human autoimmune diseases. I also showed that the mutagenic DNA adduct O(6)-methylguanine (O(6)mG) is repaired without removing the guanine from DNA, identifying a surprising mechanism by which the methyl group is transferred to a residue in the repair protein itself. A further novel process of DNA repair discovered by my research group is the action of AlkB as an iron-dependent enzyme carrying out oxidative demethylation. Copyright © 2013. Production and hosting by Elsevier Ltd.

  14. The Weekend Effect in AAA Repair.

    Science.gov (United States)

    O'Donnell, Thomas F X; Li, Chun; Swerdlow, Nicholas J; Liang, Patric; Pothof, Alexander B; Patel, Virendra I; Giles, Kristina A; Malas, Mahmoud B; Schermerhorn, Marc L

    2018-04-18

    Conflicting reports exist regarding whether patients undergoing surgery on the weekend or later in the week experience worse outcomes. We identified patients undergoing abdominal aortic aneurysm (AAA) repair in the Vascular Quality Initiative between 2009 and 2017 [n = 38,498; 30,537 endovascular aneurysm repair (EVAR) and 7961 open repair]. We utilized mixed effects logistic regression to compare adjusted rates of perioperative mortality based on the day of repair. Tuesday was the most common day for elective repair (22%), Friday for symptomatic repairs (20%), and ruptured aneurysms were evenly distributed. Patients with ruptured aneurysms experienced similar adjusted mortality whether they underwent repair during the week or on weekends. Transfers of ruptured AAA were more common over the weekend. However, patients transferred on the weekend experienced higher adjusted mortality than those transferred during the week (28% vs 21%, P = 0.02), despite the fact that during the week, transferred patients actually experienced lower adjusted mortality than patients treated at the index hospital (21% vs 31%, P AAA repair. However, patients with ruptured AAA transferred on the weekend experienced higher mortality than those transferred during the week, suggesting a need for improvement in weekend transfer processes.

  15. Component-Level Electronic-Assembly Repair (CLEAR) Operational Concept

    Science.gov (United States)

    Oeftering, Richard C.; Bradish, Martin A.; Juergens, Jeffrey R.; Lewis, Michael J.; Vrnak, Daniel R.

    2011-01-01

    This Component-Level Electronic-Assembly Repair (CLEAR) Operational Concept document was developed as a first step in developing the Component-Level Electronic-Assembly Repair (CLEAR) System Architecture (NASA/TM-2011-216956). The CLEAR operational concept defines how the system will be used by the Constellation Program and what needs it meets. The document creates scenarios for major elements of the CLEAR architecture. These scenarios are generic enough to apply to near-Earth, Moon, and Mars missions. The CLEAR operational concept involves basic assumptions about the overall program architecture and interactions with the CLEAR system architecture. The assumptions include spacecraft and operational constraints for near-Earth orbit, Moon, and Mars missions. This document addresses an incremental development strategy where capabilities evolve over time, but it is structured to prevent obsolescence. The approach minimizes flight hardware by exploiting Internet-like telecommunications that enables CLEAR capabilities to remain on Earth and to be uplinked as needed. To minimize crew time and operational cost, CLEAR exploits offline development and validation to support online teleoperations. Operational concept scenarios are developed for diagnostics, repair, and functional test operations. Many of the supporting functions defined in these operational scenarios are further defined as technologies in NASA/TM-2011-216956.

  16. Laparoscopic versus open repair for perforated peptic ulcer: A meta analysis of randomized controlled trials.

    Science.gov (United States)

    Tan, Shanjun; Wu, Guohao; Zhuang, Qiulin; Xi, Qiulei; Meng, Qingyang; Jiang, Yi; Han, Yusong; Yu, Chao; Yu, Zhen; Li, Ning

    2016-09-01

    The role of laparoscopic surgery in the repair for peptic ulcer disease is unclear. The present study aimed to compare the safety and efficacy of laparoscopic versus open repair for peptic ulcer disease. Randomized controlled trials (RCTs) comparing laparoscopic versus open repair for peptic ulcer disease were identified from MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and references of identified articles and relevant reviews. Primary outcomes were postoperative complications, mortality, and reoperation. Secondary outcomes were operative time, postoperative pain, postoperative hospital stay, nasogastric tube duration, and time to resume diet. Statistical analysis was carried out by Review Manage software. Five RCTs investigating a total of 549 patients, of whom, 279 received laparoscopic repair and 270 received open repair, were included in the final analysis. There were no significant differences between these two procedures in some primary outcomes including overal postoperative complication rate, mortality, and reoperation rate. Subcategory analysis of postoperative complications showed that laparoscopic repair had also similar rates of repair site leakage, intra-abdominal abscess, postoperative ileus, pneumonia, and urinary tract infection as open surgery, except of the lower surgical site infection rate (P peptic ulcer. The obvious advantages of laparoscopic surgery are the lower surgical site infection rate, shorter nasogastric tube duration and less postoperative pain. However, more higher quality studies should be undertaken to further assess the safety and efficacy of laparoscopic repair for peptic ulcer disease. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  17. Cellular and molecular repair of X-ray-induced damage: dependence on oxygen tension and nutritional status

    International Nuclear Information System (INIS)

    Spiro, I.J.; Kennedy, K.A.; Stickler, R.; Ling, C.C.

    1985-01-01

    Cellular and molecular repair was studied at 23 0 C using split-dose recovery and alkaline elution techniques, respectively, as a function of cellular oxygen and nutrient conditions. Hypoxic cells in full medium showed a partial reduction in the level of sublethal damage (SLD) repair relative to aerated cells; the respective repair kinetics were similar with a common repair half-time of 30 min. Similarly, hypoxic cells showed a slight reduction in strand break rejoining capacity compared to aerated cells. Under nutrient deprivation, anoxic cells displayed no SLD repair or strand break repair, while aerated cells exhibited the same level of SLD and strand break repair as for well-fed cells. In addition, nutrient deprived cells at low O 2 levels displayed normal SLD and strand break repair capability. These results indicate that both nutrient and O 2 deprivation are necessary for complete inhibition of cellular and molecular repair, and low levels of O 2 can effectively reverse this inhibition

  18. DNA repair genes

    International Nuclear Information System (INIS)

    Morimyo, Mitsuoki

    1995-01-01

    Fission yeast S. pombe is assumed to be a good model for cloning of human DNA repair genes, because human gene is normally expressed in S. pombe and has a very similar protein sequence to yeast protein. We have tried to elucidate the DNA repair mechanisms of S. pombe as a model system for those of mammals. (J.P.N.)

  19. Cardiovascular autonomic dysfunction and carotid stiffness in adults with repaired tetralogy of Fallot.

    Science.gov (United States)

    Novaković, Marko; Prokšelj, Katja; Starc, Vito; Jug, Borut

    2017-06-01

    Adults after surgical repair of tetralogy of Fallot (ToF) may have impaired vascular and cardiac autonomic function. Thus, we wanted to assess interrelations between heart rate variability (HRV) and heart rate recovery (HRR), as parameters of cardiac autonomic function, and arterial stiffness, as a parameter of vascular function, in adults with repaired ToF as compared to healthy controls. In a case-control study of adults with repaired ToF and healthy age-matched controls we measured: 5-min HRV variability (with time and frequency domain data collected), carotid artery stiffness (through pulse-wave analysis using echo-tracking ultrasound) and post-exercise HRR (cycle ergometer exercise testing). Twenty-five patients with repaired ToF (mean age 38 ± 10 years) and 10 healthy controls (mean age 39 ± 8 years) were included. Selected HRR and HRV (time-domain) parameters, but not arterial stiffness were significantly reduced in adults after ToF repair. Moreover, a strong association between late/slow HRR (after 2, 3 and 4 min) and carotid artery stiffness was detected in ToF patients (r = -0.404, p = 0.045; r = -0.545, p = 0.005 and r = -0.545, p = 0.005, respectively), with statistical significance retained even after adjusting for age, gender, resting heart rate and β-blockers use (r = -0.393, p = 0.024 for HRR after 3 min). Autonomic cardiac function is impaired in patients with repaired ToF, and independently associated with vascular function in adults after ToF repair, but not in age-matched healthy controls. These results might help in introducing new predictors of cardiovascular morbidity in a growing population of adults after surgical repair of ToF.

  20. Arthroscopic rotator cuff repair in elite rugby players.

    Science.gov (United States)

    Tambe, Amol; Badge, Ravi; Funk, Lennard

    2009-01-01

    Rugby is an increasingly popular collision sport. A wide spectrum of injuries can be sustained during training and match play. Rotator cuff injury is uncommon in contact sports and there is little published literature on the treatment of rotator cuff tears in rugby players. We therefore reviewed the results and functional outcomes of arthroscopic rotator cuff repair in elite rugby players. Eleven professional rugby players underwent arthroscopic rotator cuff repair at our hospital over a 2-year period. We collected data on these patients from the operative records. The patients were recalled for outcome scoring and ultrasound scans. There were seven rugby league players and four rugby union players, including six internationals. Their mean age was 25.7 years. All had had a traumatic episode during match play and could not return to the game after the injury. The mean time to surgery was 5 weeks. The mean width of the cuff tear was 1.8 cm. All were full- thickness cuff tears. Associated injuries included two Bankart lesions, one bony Bankart lesion, one posterior labral tear, and two 360 degrees labral tears. The biceps was involved in three cases. Two were debrided and a tenodesis was performed in one. Repair was with suture anchors. Following surgery, all patients underwent a supervised accelerated rehabilitation programme. The final follow-up was at 18 months (range: 6-31 months) post surgery. The Constant scores improved from 44 preoperatively to 99 at the last follow-up. The mean score at 3 months was 95. The Oxford shoulder score improved from 34 to 12, with the mean third month score being 18. The mean time taken to return to full match play at the preinjury level was 4.8 months. There were no complications in any of the patients and postoperative scans in nine patients confirmed that the repairs had healed. We conclude that full-thickness rotator cuff tears in the contact athlete can be addressed successfully by arthroscopic repair, with a rapid return to

  1. Prototype fast reactor steam generator unit pressure vessel repairs

    International Nuclear Information System (INIS)

    Daniels, B.D.; Green, D.; Henderson, J.D.C.

    1993-01-01

    The prototype fast reactor at Dounreay has experienced a number of unscheduled shutdowns due to leaking reheater and superheater shell welds. There was a need to determine the cracking mechanism and to design a general repair technique simultaneously. Detailed investigations revealed that the crack locations correlated with the positions of rectification welds made at the time of vessel manufacture. A creep crack growth mechanism was identified; this requires through wall residual stress for through cracks to develop. A repair technique has been devised and successfully applied to the sites of a number of leaks. (author)

  2. Prediction of Combine Economic Life Based on Repair and Maintenance Costs Model

    Directory of Open Access Journals (Sweden)

    A Rohani

    2014-09-01

    Full Text Available Farm machinery managers often need to make complex economic decisions on machinery replacement. Repair and maintenance costs can have significant impacts on this economic decision. The farm manager must be able to predict farm machinery repair and maintenance costs. This study aimed to identify a regression model that can adequately represent the repair and maintenance costs in terms of machine age in cumulative hours of use. The regression model has the ability to predict the repair and maintenance costs for longer time periods. Therefore, it can be used for the estimation of the economic life. The study was conducted using field data collected from 11 John-Deer 955 combine harvesters used in several western provinces of Iran. It was found that power model has a better performance for the prediction of combine repair and maintenance costs. The results showed that the optimum replacement age of John-Deer 955 combine was 54300 cumulative hours.

  3. Repair of sublethal damage in mammalian cells irradiated at ultrahigh dose rates

    International Nuclear Information System (INIS)

    Gerweck, L.E.; Epp, E.R.; Michaels, H.B.; Ling, C.C.; Peterson, E.C.

    1979-01-01

    The lethal response of asynchronous Chinese hamster ovary (CHO) cells exposed to single and split doses of radiation at conventional or ultrahigh dose rates has been examined to determine whether repair of sublethal damage occurs in cells irradiated at ultrahigh dose rates. The high-intensity irradiations were performed with electrons delivered in single 3-nsec pulses from a 600-kV field emission source under medium-removed, thin-layer conditions. Conventional dose-rate experiments were done under identical thin-layer conditions with 50-kVp x rays, or under full-medium conditions with 280-kVp x rays. Oxygenated cells were irradiated and maintained at 22 to 24 0 C between exposures. Survival did not increase as the time between two doses of pulsed electrons increased from 0 to 4 min, indicating no evidence of fast repair. However, increased survival was observed when 30 to 90 min was allowed to elapse between the split doses. The half-time for maximum repair was approx. = 30 min irrespective of the exposure conditions and radiation modality used. Observed repair ratios increased from approx. = 2 to 4 as the single-dose surviving fraction decreased from 10 -2 to 5 x 10 -4 . Over this survival range the repair ratios, measured at the same value of surviving fraction, were independent of dose rate. The observed repair ratios imply that the shoulder regions of the nonfractionated x-ray and pulsed-electron survival curves were not completely restored between the split doses. However, the fraction of the shoulder restored between split doses of radiation was dose-rate-independent. It is concluded that sublethal damage can be repaired in oxygenated CHO cells irradiated at dose rates of the order of 10 11 rad/sec

  4. Mesh Plug Repair of Inguinal Hernia; Single Surgeon Experience

    Directory of Open Access Journals (Sweden)

    Ahmet Serdar Karaca

    2013-10-01

    Full Text Available Aim: Mesh repair of inguinal hernia repairs are shown to be an effective and reliable method. In this study, a single surgeon%u2019s experience with plug-mesh method performs inguinal hernia repair have been reported. Material and Method: 587 patients with plug-mesh repair of inguinal hernia, preoperative age, body / mass index, comorbid disease were recorded in terms of form. All of the patients during the preoperative and postoperative hernia classification of information, duration of operation, antibiotics, perioperative complications, and later, the early and late postoperative complications, infection, recurrence rates and return to normal daily activity, verbal pain scales in terms of time and postoperative pain were evaluated. Added to this form of long-term pain ones. The presence of wound infection was assessed by the presence of purulent discharge from the incision. Visual analog scale pain status of the patients was measured. Results: 587 patients underwent repair of primary inguinal hernia mesh plug. One of the patients, 439 (74% of them have adapted follow-ups. Patients%u2019 ages ranged from 18-86. Was calculated as the mean of 47±18:07. Follow-up period of the patients was found to be a minimum of 3 months, maximum 55 months. Found an average of 28.2±13.4 months. Mean duration of surgery was 35.07±4.00 min (min:22mn-max:52mn, respectively. When complication rates of patients with recurrence in 2 patients (0.5%, hematoma development (1.4% in 6 patients, the development of infection in 11 patients (2.5% and long-term groin pain in 4 patients (0.9% appeared. Discussion: In our experience, the plug-mesh repair of primary inguinal hernia repair safe, effective low recurrence and complication rates can be used.

  5. Male infertility after mesh hernia repair: A prospective study.

    Science.gov (United States)

    Hallén, Magnus; Sandblom, Gabriel; Nordin, Pär; Gunnarsson, Ulf; Kvist, Ulrik; Westerdahl, Johan

    2011-02-01

    Several animal studies have raised concern about the risk for obstructive azoospermia owing to vasal fibrosis caused by the use of alloplastic mesh prosthesis in inguinal hernia repair. The aim of this study was to determine the prevalence of male infertility after bilateral mesh repair. In a prospective study, a questionnaire inquiring about involuntary childlessness, investigation for infertility and number of children was sent by mail to a group of 376 men aged 18-55 years, who had undergone bilateral mesh repair, identified in the Swedish Hernia Register (SHR). Questionnaires were also sent to 2 control groups, 1 consisting of 186 men from the SHR who had undergone bilateral repair without mesh, and 1 consisting of 383 men identified in the general population. The control group from the SHR was matched 2:1 for age and years elapsed since operation. The control group from the general population was matched 1:1 for age and marital status. The overall response rate was 525 of 945 (56%). Method of approach (anterior or posterior), type of mesh, and testicular status at the time of the repair had no significant impact on the answers to the questions. Nor did subgroup analysis of the men ≤40 years old reveal any significant differences. The results of this prospective study in men do not support the hypothesis that bilateral inguinal hernia repair with alloplastic mesh prosthesis causes male infertility at a significantly greater rate than those operated without mesh. Copyright © 2011 Mosby, Inc. All rights reserved.

  6. Transected sciatic nerve repair by diode laser protein soldering.

    Science.gov (United States)

    Fekrazad, Reza; Mortezai, Omid; Pedram, MirSepehr; Kalhori, Katayoun Am; Joharchi, Khojasteh; Mansoori, Korosh; Ebrahimi, Roja; Mashhadiabbas, Fatemeh

    2017-08-01

    Despite advances in microsurgical techniques, repair of peripheral nerve injuries (PNI) is still a major challenge in regenerative medicine. The standard treatment for PNI includes suturing and anasthomosis of the transected nerve. The objective of this study was to compare neurorraphy (nerve repair) using standard suturingto diode laser protein soldering on the functional recovery of transected sciatic nerves. Thirty adult male Fischer-344 Wistar rats were randomly assigned to 3 groups: 1. The control group, no repair, 2. the standard of care suture group, and 3. The laser/protein solder group. For all three groups, the sciatic nerve was transected and the repair was done immediately. For the suture repair group, 10.0 prolene suture was used and for the laser/protein solder group a diode laser (500mW output power) in combination with bovine serum albumen and indocyanine green dye was used. Behavioral assessment by sciatic functional index was done on all rats biweekly. At 12weeks post-surgery, EMG recordings were done on all the rats and the rats were euthanized for histological evaluation of the sciatic nerves. The one-way ANOVA test was used for statistical analysis. The average time required to perform the surgery was significantly shorter for the laser-assisted nerve repair group compared to the suture group. The EMG evaluation revealed no difference between the two groups. Based on the sciatic function index the laser group was significantly better than the suture group after 12weeks (pneurorraphy using standard suturing methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Repair of steam turbines by welding

    International Nuclear Information System (INIS)

    Bohnstedt, H.J.; Loebert, P.

    1987-01-01

    In some cases, turbine parts can be repaired by welding, even rotating parts such as the shaft or the blades. Practical examples of successful repair work are explained, as for instance: welding of the last web of the turbine wheel of two MD-rotors, repair of erosion damage on turbine blades, of solid-matter erosion on a medium-pressure blading, or welding repair of a high-pressure turbine casing. (DG) [de

  8. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  9. Bone Injury and Repair Trigger Central and Peripheral NPY Neuronal Pathways.

    Directory of Open Access Journals (Sweden)

    Cecília J Alves

    Full Text Available Bone repair is a specialized type of wound repair controlled by complex multi-factorial events. The nervous system is recognized as one of the key regulators of bone mass, thereby suggesting a role for neuronal pathways in bone homeostasis. However, in the context of bone injury and repair, little is known on the interplay between the nervous system and bone. Here, we addressed the neuropeptide Y (NPY neuronal arm during the initial stages of bone repair encompassing the inflammatory response and ossification phases in femoral-defect mouse model. Spatial and temporal analysis of transcriptional and protein levels of NPY and its receptors, Y1R and Y2R, reported to be involved in bone homeostasis, was performed in bone, dorsal root ganglia (DRG and hypothalamus after femoral injury. The results showed that NPY system activity is increased in a time- and space-dependent manner during bone repair. Y1R expression was trigged in both bone and DRG throughout the inflammatory phase, while a Y2R response was restricted to the hypothalamus and at a later stage, during the ossification step. Our results provide new insights into the involvement of NPY neuronal pathways in bone repair.

  10. Improving left ventricular outflow tract obstruction repair in common atrioventricular canal defects.

    Science.gov (United States)

    Myers, Patrick O; del Nido, Pedro J; Marx, Gerald R; Emani, Sitaram; Mayer, John E; Pigula, Frank A; Baird, Christopher W

    2012-08-01

    Left ventricular outflow tract obstruction (LVOTO) is the second most frequent reason for reoperation after atrioventricular canal (AVC) defect repair. Limited data are available on the mechanisms of LVOTO, their treatment, and outcomes. Between 1998 and 2010, 56 consecutive children with AVC underwent 68 LVOTO procedures. The AVC was partial in 4, transitional in 9, and complete in 43. The LVOTO procedure was required in 21 patients at the primary AVC repair, and the initial LVOTO procedure in 35 patients was a late reoperation after AVC repair. During a mean follow-up of 50±41 months, 5 patients (24%) with LVOTO repair at AVC repair required a reoperation for LVOTO, and 7 patients (20%) whose initial LVOTO repair was a reoperation required a second reoperation for LVOTO repair. Overall freedom from LVOTO reoperation was 98.5% at 1 year, 92.5% at 3 years, 81% at 5 years, 72.2% at 7 years, and 52.5% at 10 and 12 years. The freedom from reoperation was neither significantly different between partial, transitional, and complete AVC (p=0.78) nor between timing of the LVOT procedure (p=0.49). Modified single-patch AVC repair was associated with a higher LVOTO reoperation rate (p=0.04). Neither the mechanisms leading to LVOTO nor the surgical techniques used were independent predictors of reoperation. LVOTO in AVC is a complex and multifactorial disease. Aggressive surgical repair has improved late outcomes; however, risk factors for reoperation and the ideal approach for repair remain to be defined. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. A comparative study of onlay and retrorectus mesh placement in incisional hernia repair

    Directory of Open Access Journals (Sweden)

    Kundan Kharde

    2013-01-01

    Full Text Available Introduction: Incisional hernia after abdominal surgery is a well-known complication and the incidence of incisional hernias continues to be 2-11% after laparotomy. The repair of incisional hernia has always been a challenge to the surgeon. Various operative techniques for the repair of incisional hernia are in practice; however, the management is not standardized. The retro-rectus mesh placement or the sub-lay technique, popularized by Rives and Stoppa in Europe, has been reported to be quite effective, with low recurrence rates (0-23% and minimal complications. Aims and Objective: The purpose of this study was to compare the traditional on-lay mesh and retro-rectus mesh placement in incisional hernia repairs in terms of time taken for surgery, early complications (wound infections, Mesh extrusion, and Delayed complications (Recurrence. Materials and Methods: This is a prospective study which was conducted in the surgical department of our hospital. A total of 50 cases were included in this study. Of these cases, 25 cases were operated by the on-lay mesh method and 25 by retro-rectus mesh placement. Only the patients with midline hernias up to 10 cm in diameter were included in the study. Result: The operative time for retro-rectus mesh placement was insignificantly higher than that of on-lay mesh repair, whereas, complications like superficial Surgical site infection SSI were identical in both the study groups, but deep SSI leading to infection of mesh was higher in on-lay mesh repair. The recurrence rate was found to be 4% in on-lay mesh repair and 0% in retro-rectus mesh repair. Conclusion: The follow-up period in this study was 6months; hence, late recurrences were not taken into account. However, the low rate of local complications and the low recurrence rate indicate that retro-rectus mesh repair has an advantage over traditional on-lay repair.

  12. Repair of Clustered Damage and DNA Polymerase Iota.

    Science.gov (United States)

    Belousova, E A; Lavrik, O I

    2015-08-01

    Multiple DNA lesions occurring within one or two turns of the DNA helix known as clustered damage are a source of double-stranded DNA breaks, which represent a serious threat to the cells. Repair of clustered lesions is accomplished in several steps. If a clustered lesion contains oxidized bases, an individual DNA lesion is repaired by the base excision repair (BER) mechanism involving a specialized DNA polymerase after excising DNA damage. Here, we investigated DNA synthesis catalyzed by DNA polymerase iota using damaged DNA templates. Two types of DNA substrates were used as model DNAs: partial DNA duplexes containing breaks of different length, and DNA duplexes containing 5-formyluracil (5-foU) and uracil as a precursor of apurinic/apyrimidinic sites (AP) in opposite DNA strands. For the first time, we showed that DNA polymerase iota is able to catalyze DNA synthesis using partial DNA duplexes having breaks of different length as substrates. In addition, we found that DNA polymerase iota could catalyze DNA synthesis during repair of clustered damage via the BER system by using both undamaged and 5-foU-containing templates. We found that hPCNA (human proliferating cell nuclear antigen) increased efficacy of DNA synthesis catalyzed by DNA polymerase iota.

  13. Human DNA repair and recombination genes

    International Nuclear Information System (INIS)

    Thompson, L.H.; Weber, C.A.; Jones, N.J.

    1988-09-01

    Several genes involved in mammalian DNA repair pathways were identified by complementation analysis and chromosomal mapping based on hybrid cells. Eight complementation groups of rodent mutants defective in the repair of uv radiation damage are now identified. At least seven of these genes are probably essential for repair and at least six of them control the incision step. The many genes required for repair of DNA cross-linking damage show overlap with those involved in the repair of uv damage, but some of these genes appear to be unique for cross-link repair. Two genes residing on human chromosome 19 were cloned from genomic transformants using a cosmid vector, and near full-length cDNA clones of each gene were isolated and sequenced. Gene ERCC2 efficiently corrects the defect in CHO UV5, a nucleotide excision repair mutant. Gene XRCC1 normalizes repair of strand breaks and the excessive sister chromatid exchange in CHO mutant EM9. ERCC2 shows a remarkable /approximately/52% overall homology at both the amino acid and nucleotide levels with the yeast RAD3 gene. Evidence based on mutation induction frequencies suggests that ERCC2, like RAD3, might also be an essential gene for viability. 100 refs., 4 tabs

  14. UV-sensitivity and repair of UV-damage in Salmonella of wild type

    International Nuclear Information System (INIS)

    Kondratiev, Y.S.; Brukhansky, G.V.; Andreeva, I.V.; Skavronskaya, A.G.

    1977-01-01

    The UV-sensitivity of wild type Salmonella strains has been compared to that of wild type E.coli and its UV-sensitive mutants. Many wild type Salmonella strains are 4-5 times more sensitive than wild type E.coli and their inactivation curve is similar to that for E.coli with a mutation in the polA gene. Alkaline sucrose gradient centrifugation has shown a deficiency of these strains in normal excision repair of UV-damaged DNA. This deficiency is not a Salmonella genus feature because one strain as resistant as wild type E.coli was found. This resistant strain showed normal excision repair in alkaline sucrose gradient centrifugation experiments. The possible influence of plasmids and mutations in repair genes on the ability of Salmonella to repair UV-damaged DNA is discussed. (orig.) [de

  15. UV-sensitivity and repair of UV-damage in Salmonella of wild type

    Energy Technology Data Exchange (ETDEWEB)

    Kondratiev, Y S; Brukhansky, G V; Andreeva, I V; Skavronskaya, A G [Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Ehpidemiologii i Mikrobiologii

    1977-12-01

    The UV-sensitivity of wild type Salmonella strains has been compared to that of wild type E.coli and its UV-sensitive mutants. Many wild type Salmonella strains are 4-5 times more sensitive than wild type E.coli and their inactivation curve is similar to that for E.coli with a mutation in the polA gene. Alkaline sucrose gradient centrifugation has shown a deficiency of these strains in normal excision repair of UV-damaged DNA. This deficiency is not a Salmonella genus feature because one strain as resistant as wild type E.coli was found. This resistant strain showed normal excision repair in alkaline sucrose gradient centrifugation experiments. The possible influence of plasmids and mutations in repair genes on the ability of Salmonella to repair UV-damaged DNA is discussed.

  16. A study of everyday repair: informing interaction design

    OpenAIRE

    Maestri, Leah Adriana

    2012-01-01

    Repair is typically seen in design as the restoration of broken objects to their original state. Repair by non-experts, or everyday repair, can often lead to novel forms of repair resulting in the creative repurposing of objects that are often unforeseen by designers. Using a grounded theory approach, this study describes key aspects of repair including: the techniques non-experts employ for repairing their objects; the motivations that prompt acts of repair; and the outcomes that result fr...

  17. Impact of the New Abbott mPLUS feature on clinical laboratory efficiencies of abbott RealTime assays for detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae.

    Science.gov (United States)

    Lucic, Danijela; Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-12-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents.

  18. Molecular biological mechanisms I. DNA repair

    International Nuclear Information System (INIS)

    Friedl, A.A.

    2000-01-01

    Cells of all living systems possess a variety of mechanisms that allow to repair spontaneous and exogeneously induced DNA damage. DNA repair deficiencies may invoke enhanced sensitivity towards DNA-damaging agents such as ionizing radiation. They may also enhance the risk of cancer development, both spontaneously or after induction. This article reviews several DNA repair mechanisms, especially those dealing with DNA double-strand breaks, and describes hereditary diseases associated with DNA repair defects. (orig.) [de

  19. The repair and protection of reinforced concrete with migrating corrosion inhibitors

    International Nuclear Information System (INIS)

    Stefanescu, D.

    2016-01-01

    The concrete is a very durable construction material and his use is based on the principle that concrete is an ideal environment for steel if properly proportioned and placed. In general, reinforced concrete has proved to be successful in terms of both structural performance and durability. However, there are instances of premature failure of reinforced concrete components due to corrosion of the reinforcement. Experience has shown that there are certain portions of exposed concrete structures more vulnerable than others. Methodology for concrete repair it addresses to suggestions of the types of repair methods and materials and a detailed description of the uses, limitations, materials, and procedures for Repair of Concrete. At same the time the methodology presents recommendation on materials, methods of mixing, application, curing and precautions to be exercised during placement. This work presents guidelines for managing reinforced concrete components and specifies the repair strategy with inhibitors incorporating. (authors)

  20. Dynamic maps of UV damage formation and repair for the human genome.

    Science.gov (United States)

    Hu, Jinchuan; Adebali, Ogun; Adar, Sheera; Sancar, Aziz

    2017-06-27

    Formation and repair of UV-induced DNA damage in human cells are affected by cellular context. To study factors influencing damage formation and repair genome-wide, we developed a highly sensitive single-nucleotide resolution damage mapping method [high-sensitivity damage sequencing (HS-Damage-seq)]. Damage maps of both cyclobutane pyrimidine dimers (CPDs) and pyrimidine-pyrimidone (6-4) photoproducts [(6-4)PPs] from UV-irradiated cellular and naked DNA revealed that the effect of transcription factor binding on bulky adducts formation varies, depending on the specific transcription factor, damage type, and strand. We also generated time-resolved UV damage maps of both CPDs and (6-4)PPs by HS-Damage-seq and compared them to the complementary repair maps of the human genome obtained by excision repair sequencing to gain insight into factors that affect UV-induced DNA damage and repair and ultimately UV carcinogenesis. The combination of the two methods revealed that, whereas UV-induced damage is virtually uniform throughout the genome, repair is affected by chromatin states, transcription, and transcription factor binding, in a manner that depends on the type of DNA damage.