WorldWideScience

Sample records for repair heating ventilation

  1. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  2. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain......This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...

  3. Ventilation and Heat Recovering System

    Directory of Open Access Journals (Sweden)

    Olga Bancea

    2007-01-01

    Full Text Available Some aspects concerning the heat reducing for ventilation, achieved by using heat recovering components and a combined heating--ventilating system, assuring both comfort and human health are presented. The floor imbedded systems together with air outlets elements could fulfill all the aesthetically desires, as well as comfort and they are ideal for family houses.

  4. Heating, ventilation and cooling

    CSIR Research Space (South Africa)

    Osburn, L

    2009-02-01

    Full Text Available content and is evaporated by the air stream with less moisture. Enthalpy wheels are more effective at transferring energy between the air streams as both sensible and latent heat is transferred. Ground-Coupled Heat Exchanger Ground-coupled heat... with high diurnal temperature variations. Evaporative Coolers Evaporative coolers work on the concept that the evaporation of water has a cooling effect on its immediate environment due to the latent heat that it absorbs in order to evaporate...

  5. Ventilation effectiveness : health benefits of heat recovery ventilators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-08-15

    Studies have shown that the installation of a heat recovery ventilator (HRV) in homes in northern Canada could improve indoor air quality and the respiratory health of inhabitants. Low ventilation rates are common in many homes in the North because the climate is severe, homes are smaller and lack basements, and occupancies are higher, leading to unhealthy indoor air quality. Northern communities also have a high rate of respiratory infections. HRVs recover much of the energy used to ventilate, which is desirable in cold regions with high heating costs. For the study, the test sample was divided into two types of houses, notably houses with active HRVs and those with control HRVs that were installed and operated but that did not function. The study results showed that HRVs provided increased ventilation. Complaints by residents about HRV noise, discomfort, or low humidity were common but equally spread between those with active and placebo HRVs. The study showed that the system design needs to be improved to better suit the needs of Inuit families. The nature of northern housing presents installation and maintenance challenges. It is hard to retrofit HRV ducting inside small, existing houses, and building supplies arrive infrequently, so detailed planning and careful take-offs of all supplies and materials must be done well in advance of construction. In addition, contractors are hard to locate and have variable expertise, and there is little technical follow-up. Robust technical support by local contractors and housing authorities is therefore important. 2 refs.

  6. VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

    Directory of Open Access Journals (Sweden)

    Vyacheslav Pisarev

    2016-11-01

    Full Text Available Ventilation systems consume more and more energy because of the often complex treatment of the air supplied to closed spaces. Looking for sources of energy allow for significant savings costs, which often translate into renewable energy sources. One of the more popular solutions is to use energy from the ground by various methods. Known and relatively common solutions are based on ground heat exchanger and ground collector cooperating with a heat pump. The paper presents the possibility of cooperation ventilation system with ground air heat exchanger and heat pump both in summer and winter period. A number solutions of this type of system, supported by calculation examples and moist air transformation in the Moliere chart have been presented. Support ventilation system with renewable energy sources allows significant savings in operating as shown in the article.

  7. Heating, ventilation and air conditioning system modelling

    Energy Technology Data Exchange (ETDEWEB)

    Whalley, R.; Abdul-Ameer, A. [British University in Dubai (United Arab Emirates)

    2011-03-15

    Heating, ventilation and air conditioning modelling methods, for large scale, spatially dispersed systems are considered. Existing techniques are discussed and proposals for the application of novel analysis approaches are outlined. The use of distributed-lumped parameter procedures enabling the incorporation of the relatively concentrated and significantly dispersed, system element characteristics, is advocated. A dynamic model for a heating, ventilation and air conditioning system comprising inlet and exhaust fans, with air recirculation, heating/cooling and filtration units is presented. Pressure, airflow and temperature predictions within the system are computed following input, disturbance changes and purging operations. The generalised modelling advancements adopted and the applicability of the model for heating, ventilation and air conditioning system simulation, re-configuration and diagnostics is emphasised. The employment of the model for automatic, multivariable controller design purposes is commented upon. (author)

  8. Mechanical ventilation with heat recovery in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Svendsen, Svend

    2005-01-01

    Building ventilation is necessary to achieve a healthy and comfortable indoor environment, but as energy prices continue to rise it is necessary to reduce the energy consumption. Using mechanical ventilation with heat recovery reduces the ventilation heat loss significantly, but in cold climates...... freezes to ice. The analysis of measurements from existing ventilation systems with heat recovery used in single-family houses in Denmark and a test of a standard heat recovery unit in the laboratory have clearly shown that this problem occurs when the outdoor temperature gets below approximately –5º......C. Due to the ice problem mechanical ventilation systems with heat recovery are often installed with an extra preheating system reducing the energy saving potential significantly. New designs of high efficient heat recovery units capable of continuously defrosting the ice without using extra energy...

  9. Hybrid Ventilation with Innovative Heat Recovery—A System Analysis

    Directory of Open Access Journals (Sweden)

    Bengt Hellström

    2013-02-01

    Full Text Available One of the most important factors when low energy houses are built is to have good heat recovery on the ventilation system. However, standard ventilation units use a considerable amount of electricity. This article discusses the consequences on a system level of using hybrid ventilation with heat recovery. The simulation program TRNSYS was used in order to investigate a ventilation system with heat recovery. The system also includes a ground source storage and waste water heat recovery system. The result of the analysis shows that the annual energy gain from ground source storage is limited. However, this is partly a consequence of the fact that the well functioning hybrid ventilation system leaves little room for improvements. The analysis shows that the hybrid ventilation system has potential to be an attractive solution for low energy buildings with a very low need for electrical energy.

  10. Energy Efficiency for Heating, Ventilating, Air-Conditioning Instructors.

    Science.gov (United States)

    Scharmann, Larry, Ed.; Lay, Gary, Ed.

    Intended primarily but not solely for use at the postsecondary level, this curriculum guide contains five units on energy efficiency that were designed to be incorporated into an existing program in heating, ventilating, and air-conditioning. The following topics are examined: how energy conservation pays, heating, ventilation, air-conditioning,…

  11. Energy Efficiency for Heating, Ventilating, Air-Conditioning Instructors.

    Science.gov (United States)

    Scharmann, Larry, Ed.; Lay, Gary, Ed.

    Intended primarily but not solely for use at the postsecondary level, this curriculum guide contains five units on energy efficiency that were designed to be incorporated into an existing program in heating, ventilating, and air-conditioning. The following topics are examined: how energy conservation pays, heating, ventilation, air-conditioning,…

  12. Mechanical ventilation with heat recovery in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Svendsen, Svend

    2005-01-01

    like the Northern Europe or in arctic climate like in Greenland or Alaska these ventilation systems will typically face problems with ice formation in the heat exchanger. When the warm humid room air comes in contact with the cold surfaces inside the exchanger (cooled by the outside air), the moisture......Building ventilation is necessary to achieve a healthy and comfortable indoor environment, but as energy prices continue to rise it is necessary to reduce the energy consumption. Using mechanical ventilation with heat recovery reduces the ventilation heat loss significantly, but in cold climates...... freezes to ice. The analysis of measurements from existing ventilation systems with heat recovery used in single-family houses in Denmark and a test of a standard heat recovery unit in the laboratory have clearly shown that this problem occurs when the outdoor temperature gets below approximately –5º...

  13. Integrated Bulding Heating, Cooling and Ventilation Control

    Science.gov (United States)

    Dong, Bing

    Current research studies show that building heating, cooling and ventilation energy consumption account for nearly 40% of the total building energy use in the U.S. The potential for saving energy through building control systems varies from 5% to 20% based on recent market surveys. In addition, building control affects environmental performances such as thermal, visual, air quality, etc., and occupancy such as working productivity and comfort. Building control has been proven to be important both in design and operation stages. Building control design and operation need consistent and reliable static and dynamic information from multiple resources. Static information includes building geometry, construction and HVAC equipment. Dynamic information includes zone environmental performance, occupancy and outside weather information during operation. At the same time, model-based predicted control can help to optimize energy use while maintaining indoor set-point temperature when occupied. Unfortunately, several issues in the current approach of building control design and operation impede achieving this goal. These issues include: a) dynamic information data such as real-time on-site weather (e.g., temperature, wind speed and solar radiation) and occupancy (number of occupants and occupancy duration in the space) are not readily available; b) a comprehensive building energy model is not fully integrated into advanced control for accuracy and robustness; c) real-time implementation of indoor air temperature control are rare. This dissertation aims to investigate and solve these issues based on an integrated building control approach. This dissertation introduces and illustrates a method for integrated building heating, cooling and ventilation control to reduce energy consumption and maintain indoor temperature set-point, based on the prediction of occupant behavior patterns and weather conditions. Advanced machine learning methods including Adaptive Gaussian Process

  14. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    The present study investigated different combinations of floor/ceiling heating with mixing/displacement ventilation and their impacts on the indoor air distribution and ventilation effectiveness. Measurements were performed in a room during heating season in December. The results show that indoor...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  15. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...

  16. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  17. A RESEARCH ON VENTILATION EFFICIENCY OF PIPED VENTILATION SYSTEMS IN GEOTHERMALLY HEATED GREENHOUSES

    Directory of Open Access Journals (Sweden)

    İbrahim Örüng

    2016-07-01

    Full Text Available Greenhouse play significant roles in human nutrition. Vegetable and fruit consumption at certain amounts is the basic pre-condition for a well nutrition. It is possible to produce sufficient quantities of fruits and vegetables in places with available climate conditions. However, fruits and vegetables should be grown in special buildings to have a year-long production in places without available climate conditions. These places include under-cover production facilities, greenhouses, low and high tunnel facilities. Environmental conditions are adjusted are adjusted in greenhouses as to provide proper conditions for plant growth and development. Ventilation is used to remove excess heat, moisture and carbon dioxide from the greenhouses. Either natural or mechanical ventilation is used in greenhouses. Mechanical ventilation systems have various advantages over natural systems. However, mostly natural ventilation systems are preferred because of their low installation and operational costs. Both systems operates based on negative pressure. Air exchange rates are usually low in winters and it is quite hard to evenly distribute cold fresh air within the greenhouse. Air inlets are usually placed over side walls and outlets are commonly placed along the ridge. In this study an alternative natural ventilation system was proposed for more efficient ventilation of the greenhouses. In this system, fresh air gets into the greenhouse through ventilation pipes installed beneath the greenhouse floor. The incoming fresh air also heated with geothermal hot water lines, thus direct contact of cold fresh air is prevented. The design and efficiency of piped ventilation systems were provided in this paper.

  18. State Skill Standards: Heating, Ventilation, Air Conditioning, and Refrigeration

    Science.gov (United States)

    Ball, Larry; Soukup, Dennis

    2006-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide career and technical education skill standards. The standards in this document are for Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) programs and are designed to clearly state what the student should know and be able to do upon completion of…

  19. Floor Heating with Displacement Ventilation: An Experimental and Numerical Analysis

    DEFF Research Database (Denmark)

    Causone, Francesco; Olesen, Bjarne W.; Corgnati, S.P.

    2010-01-01

    The effect of floor heating combined with displacement ventilation (DV) on thermal indoor environments and indoor air quality (IAQ) was studied by means of CFD. The numerical model was validated with experimental data. A typical office room was simulated, and one of the occupants was considered...... to simulate different kinds of contaminant sources, under the same boundary conditions. It was found that DV does not guarantee a better IAQ than full mixing when contaminant sources are not linked to heat sources, even when floor heating is used. Contaminants produced by powerful heat sources require high...

  20. Nosehouse: heat-conserving ventilators based on nasal counterflow exchangers.

    Science.gov (United States)

    Vogel, Steven

    2009-12-01

    Small birds and mammals commonly minimize respiratory heat loss with reciprocating counterflow exchangers in their nasal passageways. These animals extract heat from the air in an exhalation to warm those passageways and then use that heat to warm the subsequent inhalation. Although the near-constant volume of buildings precludes direct application of the device, a pair of such exchangers located remotely from each other circumvents that problem. A very simple and crudely constructed small-scale physical model of the device worked well enough as a heat conserver to suggest utility as a ventilator for buildings.

  1. Natural Ventilation with Heat Recovery: A Biomimetic Concept

    Directory of Open Access Journals (Sweden)

    Zulfikar A. Adamu

    2015-05-01

    Full Text Available In temperate countries, heat recovery is often desirable through mechanical ventilation with heat recovery (MVHR. Drawbacks of MVHR include use of electric power and complex ducting, while alternative passive heat recovery systems in the form of roof or chimney-based solutions are limited to low rise buildings. This paper describes a biomimetic concept for natural ventilation with heat recovery (NVHR. The NVHR system mimics the process of water/mineral extraction from urine in the Loop of Henle (part of human kidney. Simulations on a facade-integrated Chamber successfully imitated the geometry and behaviour of the Loop of Henle (LoH. Using a space measuring 12 m2 in area and assuming two heat densities of 18.75 W/m2 (single occupancy or 30 W/m2 (double occupancy, the maximum indoor temperatures achievable are up to 19.3 °C and 22.3 °C respectively. These come with mean relative ventilation rates of 0.92 air changes per hour (ACH or 10.7 L·s−1 and 0.92 ACH (11.55 L·s−1, respectively, for the month of January. With active heating and single occupant, the LoH Chamber consumes between 65.7% and 72.1% of the annual heating energy required by a similar naturally ventilated space without heat recovery. The LoH Chamber could operate as stand-alone indoor cabinet, benefitting refurbishment of buildings and evading constraints of complicated ducting, external aesthetic or building age.

  2. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  3. Heat Recovery Ventilation for Housing: Air-to-Air Heat Exchangers.

    Science.gov (United States)

    Corbett, Robert J.; Miller, Barbara

    The air-to-air heat exchanger (a fan powered ventilation device that recovers heat from stale outgoing air) is explained in this six-part publication. Topic areas addressed are: (1) the nature of air-to-air heat exchangers and how they work; (2) choosing and sizing the system; (3) installation, control, and maintenance of the system; (4) heat…

  4. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    Approved for public release: distribution unlimited TDS-NAVFAC-EXWC-PW-1603 Sep 2016 HVAC ; Heating, Ventilation, Air Conditioning - Aerosol...energy consumption, depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is...Although several studies have been done on the effectiveness of sealing leaky HVAC ductwork with aerosol duct sealant, few studies have been done on

  5. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    OpenAIRE

    H. Mirinejad; Sadati, S.H.; M Ghasemian; H. Torab

    2008-01-01

    Problem statement: Heating, Ventilating and Air Conditioning (HVAC) systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort fiel...

  6. 29 CFR 1915.51 - Ventilation and protection in welding, cutting and heating.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Ventilation and protection in welding, cutting and heating... Welding, Cutting and Heating § 1915.51 Ventilation and protection in welding, cutting and heating. (a) The... dust or dirt from clothing, or for cleaning the work area. (c) Welding, cutting and heating in...

  7. Mechanical ventilation with heat recovery in arctic climate

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    Mechanical ventilations systems with highly effective heat recovery units in arctic climate have problems with condensing water from the extracted humid indoor air. If the condensing water freezes to ice in the heat recovery unit, the airflow rate will quickly diminish due to the increasing...... pressure drop. Preheating the inlet air (outdoor air) to a temperature just above 0ºC is typically used to solve the problem. To minimize the energy cost, a more efficient solution to the problem is therefore desirable. In this project a new design of a heat recovery unit has been developed to the low......-energy house in Sisimiut, which is capable of continuously defrosting itself. The disadvantage of the unit is that it is quite big compared with other units. In this paper the new heat recovery unit is described and laboratory measurements are presented showing that the unit is capable of continuously...

  8. Heating, Ventilation and Air-Conditioning Systems, Part of Indoor Air Quality Design Tools for Schools

    Science.gov (United States)

    The main purposes of a Heating, Ventilation, and Air-Conditioning system are to help maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort. HVAC systems are among the largest energy consumers in schools.

  9. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou;

    2014-01-01

    The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied....../s for both ventilation systems. In addition, local ventilation effectiveness ranged from 0.91 to 0.94 for mixing ventilation and from 1.03 to 1.17 for displacement ventilation. Distributions of vertical air temperature and velocity and horizontal contaminant concentration were more uniform for mixing...... ventilation compared to those for displacement ventilation. Due to the heat emission from equipments and occupants, heating system was not needed in the low energy office building in a mild winter. In such a situation, indoor thermal environment was still acceptable in terms of the general thermal comfort...

  10. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei;

    2016-01-01

    system were determined according to the principle of heat transfer. A model to predict indoor temperatures in the room was proposed, and it was determined that the predicted indoor temperatures agreed well with the measured data. Qualitative analyses of the effects of heated surface temperature and air...... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20.......8% for calculating the transmission heat loss and ventilation heat loss, respectively, and between 16.0% and 17.4% for calculating the heating capacity of the hybrid system. Due to large relative calculation errors, it is necessary to consider the effect of heated surface and cool supply air on indoor temperatures...

  11. 29 CFR 1926.353 - Ventilation and protection in welding, cutting, and heating.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Ventilation and protection in welding, cutting, and heating... Welding and Cutting § 1926.353 Ventilation and protection in welding, cutting, and heating. (a) Mechanical... the work area. (b) Welding, cutting, and heating in confined spaces. (1) Except as provided...

  12. Identifying and removing pollutants from heat recovery ventilators

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada); Waters, T. [Sustainable Housing and Education Consultants Ltd., Wolfville, NS (Canada)

    2006-02-15

    Dedicated ventilation systems in buildings are designed to improve indoor air quality which can be degraded by mold, an abundance of cleaners, solvents and other chemical pollutants. These systems provide balanced supply and exhaust ventilation to the entire house via an air exchanger or heat recovery ventilator (HRV) and ductwork. A study in which 6 conventional houses and 4 R-2000 certified houses were tested for air and surface mold counts using an RCS air sampler and swab collection systems. The houses were built between 1987 and 1997 in Nova Scotia. Air samples were taken at 4 common sites in each house, before and after cleaning. Surface swats were taken at 7 common sites, including HRV core and supply ductwork at HRV. The objective was to determine if the dedicated ventilation systems harbour unhealthy levels of dust and mold. Another objective was to determine the effectiveness of existing duct cleaning methods such as truck-mounted systems and portable high-power vacuums. The study revealed that mold counts were high in the ductwork and cores, with consistently higher count found in the fresh air supply ducts to the HRV. Both rigid and flexible ducts were examined. Intake ducts in particular were found to be dirty and difficult to clean, especially where duct runs were long and inaccessible. The airborne mold sampling results were inconclusive as to whether any of the houses presented levels that could cause health problems. It was concluded that current duct cleaning systems are not effective for smaller diameter ductwork. Ways to improve installation and maintenance of HRV units were presented. 1 fig.

  13. Technical and economical analysis of heat recovery in building ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Padova Univ. (Italy). Istituto di Ingegneria Gestionale; Gasparella, A. [Padova Univ. (Italy). Dottorato di Ricerca in Energetica

    1998-01-01

    Heat recovery in ventilation systems can be obtained from both the sensible fraction and the latent fraction. The possible sensible and total heat recovery depends on the climate and on the operating period. Total heat recovery is limited in winter by the humidity of the supply air; this lowers the exchange capacity in the heating period. Three different climates are considered (Milan, Rome, Palermo), evaluating the recovery for unitary air ventilation flow rate and the economic savings, also taking into account the reduction in the heating or cooling capacity. Heat recovery in a ventilating system must always be evaluated, since the investment is often profitable. (author)

  14. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    OpenAIRE

    Wu, Xiaozhou; Fang,Lei; Olesen, Bjarne W.; Zhao, Jianing

    2014-01-01

    The present study investigated different combinations of floor/ceiling heating with mixing/displacement ventilation and their impacts on the indoor air distribution and ventilation effectiveness. Measurements were performed in a room during heating season in December. The results show that indoor vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface ...

  15. Mechanical ventilation injury and repair in extremely and very preterm lungs.

    Directory of Open Access Journals (Sweden)

    Nadine Brew

    Full Text Available BACKGROUND: Extremely preterm infants often receive mechanical ventilation (MV, which can contribute to bronchopulmonary dysplasia (BPD. However, the effects of MV alone on the extremely preterm lung and the lung's capacity for repair are poorly understood. AIM: To characterise lung injury induced by MV alone, and mechanisms of injury and repair, in extremely preterm lungs and to compare them with very preterm lungs. METHODS: Extremely preterm lambs (0.75 of term were transiently exposed by hysterotomy and underwent 2 h of injurious MV. Lungs were collected 24 h and at 15 d after MV. Immunohistochemistry and morphometry were used to characterise injury and repair processes. qRT-PCR was performed on extremely and very preterm (0.85 of term lungs 24 h after MV to assess molecular injury and repair responses. RESULTS: 24 h after MV at 0.75 of term, lung parenchyma and bronchioles were severely injured; tissue space and myofibroblast density were increased, collagen and elastin fibres were deformed and secondary crest density was reduced. Bronchioles contained debris and their epithelium was injured and thickened. 24 h after MV at 0.75 and 0.85 of term, mRNA expression of potential mediators of lung repair were significantly increased. By 15 days after MV, most lung injury had resolved without treatment. CONCLUSIONS: Extremely immature lungs, particularly bronchioles, are severely injured by 2 h of MV. In the absence of continued ventilation these injured lungs are capable of repair. At 24 h after MV, genes associated with injurious MV are unaltered, while potential repair genes are activated in both extremely and very preterm lungs.

  16. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...... supplying warm air space heating or by a combination of radiant floor heating and mixing ventilation system. Next two test setups simulated an office room with two occupants during summer, ventilated and cooled by a single displacement ventilation system or by a radiant floor cooling combined...... and about one third preferred more air movement. No significant difference in thermal perception between the two displacement ventilation systems was found....

  17. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou

    2014-01-01

    ventilation compared to those for displacement ventilation. Due to the heat emission from equipments and occupants, heating system was not needed in the low energy office building in a mild winter. In such a situation, indoor thermal environment was still acceptable in terms of the general thermal comfort......The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied...

  18. 21 CFR 211.46 - Ventilation, air filtration, air heating and cooling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Ventilation, air filtration, air heating and... Buildings and Facilities § 211.46 Ventilation, air filtration, air heating and cooling. (a) Adequate... holding of a drug product. (c) Air filtration systems, including prefilters and particulate matter...

  19. 8th International Symposium on Heating, Ventilation and Air Conditioning

    CERN Document Server

    Zhu, Yingxin; Li, Yuguo; Vol.1 Indoor and Outdoor Environment; Vol.2 HVAC&R Component and Energy System; Vol.3 Building Simulation and Information Management

    2014-01-01

    Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning is based on the 8th International Symposium of the same name (ISHVAC2013), which took place in Xi’an on October 19-21, 2013. The conference series was initiated at Tsinghua University in 1991 and has since become the premier international HVAC conference initiated in China, playing a significant part in the development of HVAC and indoor environmental research and industry around the world. This international conference provided an exclusive opportunity for policy-makers, designers, researchers, engineers and managers to share their experience. Considering the recent attention on building energy consumption and indoor environments, ISHVAC2013 provided a global platform for discussing recent research on and developments in different aspects of HVAC systems and components, with a focus on building energy consumption, energy efficiency and indoor environments. These categories span a broad range of topics, and the proce...

  20. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou

    2014-01-01

    The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied...... zone was 21.0°C for mixing ventilation and 20.8°C for displacement ventilation when supply air temperature was 19°C and air change rate was 4.2 h-. Vertical air temperature difference between the head level and the foot level were all less than 3°C and local air velocity were all less than 0.2m....../s for both ventilation systems. In addition, local ventilation effectiveness ranged from 0.91 to 0.94 for mixing ventilation and from 1.03 to 1.17 for displacement ventilation. Distributions of vertical air temperature and velocity and horizontal contaminant concentration were more uniform for mixing...

  1. Experimental analysis of energy performance of a ventilated window for heat recovery under controlled conditions

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend

    2011-01-01

    A ventilated window in cold climates can be considered as a passive heat recovery system. This study carried out tests to determine the thermal transmittance of ventilated windows by using the Guarded Hot Box. By testing under defined boundary conditions, the investigation described the heat......, it was found that a significant part of preheating occurred through the window frames, which positively influenced the heat recovery of the window but increased the heat loss. Results also showed that increasing air flow decreased the recovery efficiency until the point when the additional thermal...... transmittance introduced by the ventilation was higher than the effect of heat recovery. Accordingly, the use of the ventilated windows might be most suitable for window unit with low ventilation rates. The results correlated with theoretical calculations in standards and software. However, the concept...

  2. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices....... Contaminant removal effectiveness and air change efficiency were used to evaluate ventilation effectiveness. No significant risk of thermal discomfort due to vertical air temperature differences or draught was found. When the room was heated by warm air, buoyancy forces were important for ventilation...

  3. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal;

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...... with a floor system for heating or cooling. Can, for example, a floor heating system warm up the supply air too fast and destroy the displacement effect? Will floor cooling, combined with displacement ventilation, result in too high a vertical temperature difference and too low a temperature at feet level......? The required amount of ventilation depends on the ventilation effectiveness. In standards, the recommended values for ventilation effectiveness depend on the position of the supply and exhaust device and on the difference between supply and room air temperature. Among others, for warm air heating...

  4. Ventilation System Type and the Resulting Classroom Temperature and Air Quality During Heating Season

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    The present study investigated how different ventilation system types influence classroom temperature and air quality. Five classrooms were selected in the same school. They were ventilated by manually operable windows, manually operable windows with exhaust fan, automatically operable windows...... windows. Classrooms with automatically operable windows and exhaust fan and with mechanical ventilation systems achieved the best thermal environment and air quality during heating season among all classrooms examined....... with and without exhaust fan and by mechanical ventilation system. Temperature, relative humidity, carbon dioxide (CO2) concentration and opening of windows were continuously monitored for one month during heating season in 2012. Classroom with manually operable windows had the highest carbon dioxide concentration...

  5. Influence of ventilated shrouds on the convective heat transfer to a circular cylinder

    Science.gov (United States)

    Daryabeigi, Kamran; Ash, Robert L.; Dillon-Townes, Lawrence A.

    1987-01-01

    Convective heat transfer to shrouded cylinders in transverse flow has been studied over the Reynolds number range 2000-20,000. The influence of shroud ventilation, relative shroud diameters, and orientation of the ventilation holes was studied. In some cases, average inner-cylinder Nusselt numbers were found to exceed the comparable bare-cylinder values by as much as 50 percent. Cylinder heat convection was influenced more by the degree of ventilation and shroud diameter than by hole orientation. An equivalent inner bare cylinder diameter, based on degree of shroud ventilation and shroud diameter, was developed which can be useful in shroud design studies.

  6. Humidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?

    Science.gov (United States)

    Cerpa, F; Cáceres, D; Romero-Dapueto, C; Giugliano-Jaramillo, C; Pérez, R; Budini, H; Hidalgo, V; Gutiérrez, T; Molina, J; Keymer, J

    2015-01-01

    The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optimal mainly due to the high flow that is being created by the leakage compensation, among other aspects. Any moisture and heating deficit is compensated by the large airways of the tracheobronchial tree, these are poorly suited for this task, which alters mucociliary function, quality of secretions, and homeostasis gas exchange system. To avoid the occurrence of these events, external devices that provide humidification, heating and filtration have been developed, with different degrees of evidence that support their use.

  7. Control of Single-room Ventilation with Regenerative Heat Recovery for Indoor Climate and Energy Performance

    OpenAIRE

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    The Danish government will seek energy-efficiency improvements to meet their targeted aims. Single-room ventilation with heat recovery allows simple installation through the façade and may be broadly deployed in apartments. Danish building regulations require greater than 80% heat recovery in new constructions and will soon require 85%. The development of single-room ventilation units may aim for these requirements as a result. The exhaust temperatures in highly efficient heat exchangers may ...

  8. Measurement of convective heat transfer to solid cylinders inside ventilated shrouds

    Science.gov (United States)

    Daryabeigi, K.; Germain, E. F.; Ash, R. L.

    1984-01-01

    The influence of ventilated cylindrical shrouds on the convective heat transfer to circular cylinders has been studied experimentally. Geometries studied were similar to those used in commercially available platinum resistance thermometers. Experiments showed that thermal response (convection) was enhanced when the shroud ventilation factor was approximately 20 percent (80 percent solid), and that maximum enhancement occurred when the ventilation holes were located symmetrically on either side of the stagnation lines.

  9. Selection of Heat Recovery Ventilators in Different Climate Zones of China

    Institute of Scientific and Technical Information of China (English)

    ZHONG Ke; ZHAO Jing-de; LIU Jia-ping

    2007-01-01

    Considering four different climate zones in China, an investigation on the choice of heat recovery ventilator for the buildings with little moisture emissions is carried out. The annual composition of energy consumption of air intake for per unitary air ventilation flow rate is evaluated by employing the testing data of climatic parameters in eight selected cities. The analysis shows that the total heat recovery is suitable in a controlled ventilation system with air humidity controlled during heating period of all the climates. For the building without air humidity controlled in winter, the sensible heat recovery ventilators can be used in severe cold and cold regions, and total heat recovery systems are more suitable for energy saving in hot summer and cold winter and hot summer and warm winter regions.

  10. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    H. Mirinejad

    2008-01-01

    Full Text Available Problem statement: Heating, Ventilating and Air Conditioning (HVAC systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort field is introduced, followed by a review and comparison of the main existing control techniques used in HVAC systems to date. Results: The present overview shows that intelligent controllers which are based on the human sensation of thermal comfort have a better performance in providing thermal comfort as well as energy saving than the traditional controllers and those based on a model of the HVAC system. Conclusion: Such an overview provides an insight into current control methods in HVAC systems and can help scholars and HVAC learners to have the comprehensive information about a variety of control techniques in the field of HVAC and therefore to better design a proper controller for their work

  11. A comparison of winter pre-heating requirements for natural displacement and natural mixing ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Woods, Andrew W. [BP Institute, University of Cambridge, Cambridge, CB3 OEZ (United Kingdom); Fitzgerald, Shaun; Livermore, Stephen [E-Stack Ltd., St Johns Innovation Centre, Cambridge (United Kingdom)

    2009-12-15

    In winter, natural ventilation can be achieved either through mixing ventilation or upward displacement ventilation (P.F. Linden, The fluid mechanics of natural ventilation, Annual Review of Fluid Mechanics 31 (1999) pp. 201-238). We show there is a significant energy saving possible by using mixing ventilation, in the case that the internal heat gains are significant, and illustrate these savings using an idealized model, which predicts that with internal heat gains of order 0.1 kW per person, mixing ventilation uses of a fraction of order 0.2-0.4 of the heat load of displacement ventilation assuming a well-insulated building. We then describe a strategy for such mixing natural ventilation in an atrium style building in which the rooms surrounding the atrium are able to vent directly to the exterior and also through the atrium to the exterior. The results are motivated by the desire to reduce the energy burden in large public buildings such as hospitals, schools or office buildings centred on atria. We illustrate a strategy for the natural mixing ventilation in order that the rooms surrounding the atrium receive both pre-heated but also sufficiently fresh air, while the central atrium zone remains warm. We test the principles with some laboratory experiments in which a model air chamber is ventilated using both mixing and displacement ventilation, and compare the energy loads in each case. We conclude with a discussion of the potential applications of the approach within the context of open plan atria type office buildings. (author)

  12. INVESTIGATION OF HEAT UTILIZATION EFFICIENCY IN SUCTION AND EXHAUST VENTILATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. N. Kuzovlev

    2014-01-01

    Full Text Available The paper considers a possibility  to use a  thermal pump and heat-exchange device  in  the ventilation system  for heat utilization of exhaust air. An  influence of air characteristics on  energy  efficiency  of heat-utilizing installations has been shown in the paper. Specific feature of the thermal pump application is the fact hat a source of secondary heat has higher temperature than a consumer. The paper contains results of thermal pump and heat exchange device parameters, hat characterize their efficiency while being applied in a ventilation system.

  13. Use of Disinfectants and Sanitizers in Heating, Ventilation, Air Conditioning, and Refrigeration Systems

    Science.gov (United States)

    This letter is to brings attention several concerns that the Agency has regarding the use of sanitizer and/or disinfectant products, and other types of antimicrobial products, to treat the surfaces of heating, ventilation

  14. Flow Conditions in a Mechanically Ventilated Room with a Convective Heat Source

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    1988-01-01

    The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices.......The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices....

  15. Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Artmann, Nikolai; Jensen, Rasmus Lund

    2009-01-01

    Passive cooling by night-time ventilation is seen as a promising approach for energy efficient cooling of buildings. However, uncertainties in prediction of cooling potential and consequenses for thermal comfort restrain architects and engineers from applying this technique. Heat transfer...... at internal room surfaces determines the performance of night-time ventilation. In order to improve predictability, heat transfer mechanism in case of either mixing or displacement ventilation has been investigated in a full scale test room with an exposed ceiling as the dominating thermal mass. The influence...

  16. Experimental Investigation of Convective Heat Transfer during Night Cooling with Different Ventilation Systems and Surface Emissivities

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    Night-time ventilation is a promising approach to reduce the energy needed for cooling buildings without reducing thermal comfort. Nevertheless actual building simulation tools have showed their limits in predicting accurately the efficiency of night-time ventilation, mainly due to inappropriate...... air and the room, and floor emissivities. This extensive experimental study enabled a detailed analysis of the convective and radiative flow at the different surfaces of the room. The experimentally derived convective heat transfer coefficients (CHTC) have been compared to existing correlations...... ventilation, the convective heat transfer was well predicted by existing correlations. Nevertheless the change of floor emissivity influenced the CHTC at the surface of interest....

  17. Simulation of Velocity and Temperature Distributions of Displacement Ventilation System with Single or Double Heat Sources

    Institute of Scientific and Technical Information of China (English)

    Wenfei Wu; Xuan Wu; Yanhui Feng; Xinxin Zhang

    2007-01-01

    In order to obtain a better understanding of flow characteristics of displacement ventilation, the three-dimensional numerical models are developed using the CFD technology. The numerical simulation results are verified by experiments, based on this, the velocity and temperature distribution of three-dimensional displacement ventilation system with single and double heat sources are studied. Velocity and temperature fields under two different cases of heat source are analyzed and compared. The numerical results show that there are three layers in vertical temperature fields of displacement ventilation system with single or double heat sources, and the vertical temperature distribution of single heat source is different from that of double heat sources. When indoor load is large, the comfort requirement of people indoor can't be satisfied with displacement ventilation system only, thus an additional refrigeration system is necessary. Furthermore, under the condition of two heat sources, the displacement ventilation parameters can't be computed simply according to single heat source inlet parameters, therefore the interaction between heat sources should be considered.

  18. Summarized Data of Test Space Heating, Ventilation and Air Conditioning Inspections from the Building Assessment Survey and Evaluation Study

    Science.gov (United States)

    Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues

  19. Analytical and experimental analysis of a low-pressure heat exchanger suitable for passive ventilation

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2011-01-01

    AbstractA core element in sustainable ventilation systems is the heat recovery system. Conventional heat recovery systems have a high pressure drop that acts as blockage to naturally driven airflow. The heat recovery system we propose here consists of two separated air-to-liquid heat exchangers...... interconnected by a liquid loop powered by a pump ideal as a component in a heat recovery system for passive ventilation systems. This paper describes the analytical framework and the experimental development of one exchanger in the liquid-loop. The exchanger was constructed from the 8mm plastic tubing....... Within the analytical framework, the total heat recovery of two liquid-coupled exchangers was calculated to be in the range 64.5–75.4%, depending on the parasitic heat loss in the experimental setup. The total pressure drop of the heat recovery system is 0.74Pa. Moreover, preliminary improvement...

  20. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li;

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  1. Energy efficient heating and ventilation of large halls

    CERN Document Server

    Hojer, Ondrej; Kabele, Karel; Kotrbaty, Miroslav; Sommer, Klaus; Petras, Dusan

    2011-01-01

    This guidebook is focused on modern methods for design, control and operation of energy efficient heating systems in large spaces and industrial halls. The book deals with thermal comfort, light and dark gas radiant heaters, panel radiant heating, floor heating and industrial air heating systems. Various heating systems are illustrated with case studies. Design principles, methods and modeling tools are presented for various systems.

  2. New counter flow heat exchanger designed for ventilation systems in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Nielsen, Toke Rammer

    2007-01-01

    In cold climates, mechanical ventilation systems with highly efficient heat recovery will experience problems with condensing water from the extracted humid indoor air. If the condensed water changes to ice in the heat exchanger, the airflow rate will quickly fall due to the increasing pressure...

  3. Low-energy buildings. Room heating, service water heating, ventilation; Niedrigenergiehaus. Heizung, Warmwasser und Lueftung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Emissions and primary energy consumption of technical facilities in low-energy buildings are discussed in the ASUE brochure 'Energy consumption and carbon dioxide emissions: Heating systems in low-energy buildings'. This brochure discusses the specific characteristics of heat supply in a low-energy building. It also describes controlled ventilation, the effects of the users' behavour patterns, possibilities of integrating renewables, and examples from heating systems in low-energy single family dwellings to district heating with cogeneration systems. [German] Eine Uebersicht ueber die Emissionen und Primaerenergieverbraeuche verschiedener Systeme im Niedrigenergiehaus gibt die ASUE-Broschuere 'Energieverbrauch und CO{sub 2}-Emissionen: Heizsysteme im Niedrigenergiehaus'. Die vorliegende Broschuere geht auf die geaenderten Anforderungen an die Waermeversorgung in einem Niedrigenergiehaus ein. Die Broschuere stellt ferner die kontrollierte Wohnungslueftung, den Einfluss des Nutzerverhaltens, die Moeglichkeiten zur Einbindung erneuerbarer Energien sowie Beispiele von der Heizung im Niedrigenergie-Einfamilienhaus bis zur Nahwaermeloesung mit Blockheizkraftwerk vor. (orig.)

  4. CLEAN-AIR heat pump. Reduced energy consumption for ventilation in buildings by integrating air cleaning and heat pump. Final Report; CLEAN-AIR heat pump - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Fang, L.; Olesen, Bjarne W.; Molinaro, G.; Simmonsen, P.; Skocajic, S. [Danmarks Tekniske Univ. Institut for Byggeri og Anlaeg, Lyngby (Denmark); Hummelshoej, R.M.; Carlassara, L. [COWI A/S, Lyngby, (Denmark); Groenbaek, H.; Hansen, Ole R. [Exhausto A/S, Langeskov (Denmark)

    2011-07-01

    This report summarizes task 1 of the Clean Air Heat Pump project - modelling and simulation on energy savings when using the clean air heat pump for ventilation, air cleaning and energy recovery. The total energy consumption of the proposed ventilation systems using clean air heat pump technology was calculated by a theoretical model and compared with the reference ventilation systems (conventional ventilation systems). The energy compared between the two systems includes energy used for heating, cooling and fan. The simulation and energy saving calculation was made for the application of the clean air heat pump in three typical climate conditions, i.e. mild-cold, mild-hot and hot and wet climates. Real climate data recorded from three cities in 2002 was used for the calculation. The three cities were Copenhagen (Denmark), Milan (Italy) and Colombo (Sir Lanka) which represent the above three typical climate zones. For the Danish climate (the mild cold climate), the calculations show that the ventilation system using clean air heat pump technology can save up to 42% of energy cost in winter compared to the conventional ventilation system. The energy saving in summer can be as high as 66% for the ventilation system with humidity control and 9% for the ventilation system without the requirement of humidity control. Since the Danish summer climate is very mild, over 80% of the yearly energy consumption for ventilation is used during winter season. It is, therefore, estimated that more than 35% annual energy saving for ventilation is expected in Denmark using the clean air heat pump ventilation technology. For the mild hot climate, e.g. the Italian climate, the calculations show that up to 63% of the energy saving can be achieved in summer season. For the winter mode, 17% reduction of the energy cost can be expected for the domestic use. For industrial use, the energy cost of the clean air heat pump may not be favourable due to the industrial price of gas in Italy is

  5. Ventilation Heat Recovery from Wood-Burning Domestic Flues. A Theoretical Analysis Based on a Triple Concentric Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Lionel Druette

    2013-01-01

    Full Text Available This paper presents a new air-heating system concept for energy-efficient dwellings. It is a system designed to heat a low-energy building by coupling a heat-recovery ventilation system with a three-fluid heat exchanger located on the chimney of a wood-pellet stove. The proposed work focuses on the heat transfer that occurs between flue gases, the ventilation air and the combustion air within a triple concentric tube heat exchanger with no insulation at its outer surface. The main objective is to predict outlet temperature for the specific geometry of the heat exchanger studied here. Thus, the governing differential equations are derived for a counter-co-current flow arrangement of the three fluids. Then analytical solutions for the steady-state temperature distribution are obtained as well as the amount of heat transferred to the outside. An expression for the effectiveness of the heat exchanger is also proposed. Based on these results, calculations are performed on a case study to predict the fluid temperature distribution along the heat exchanger. Finally, a parametric study is carried out on this case study to assess the influence of the relevant parameters on the effectiveness of the heat exchanger. In addition, computation of heat losses to the outside justifies whether insulation is needed.

  6. Influence of the ventilation system on thermal comfort of the chilled panel system in heating mode

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Zhe; Ding, Yan; Wang, Shuo; Yin, Xinglei; Wang, Menglei [Tianjin University, Tianjin 300072 (China)

    2010-12-15

    In heating mode, fresh air is still essential for a chilled panel system in order to ensure the indoor air quality. In this paper, a chilled ceiling panel system was designed and built in a typical office room. The thermal environment and thermal comfort in the room were fully measured and evaluated by using the Fanger's PMV-PPD model and the standard of ISO 7730 respectively, when room was heated in two modes, one of which is the chilled panel heating mode and the other of which is the combined heating mode of chilled panel and supply air. The research results indicate that in the combined mode, ceiling ventilation improves the general thermal comfort and reduces the risk of local discomfort. Under the condition of same general thermal comfort, the heating supply upper limit of chilled panel can be increased by 12.3% because of air mixing effect caused by introduction of air ventilation. (author)

  7. Control of Single-room Ventilation with Regenerative Heat Recovery for Indoor Climate and Energy Performance

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    exchanger. Available literature suggests that uncoated rotary heat exchangers transfer this condensate to the supply air, so the drying capacity of the ventilation system may be severely limited. This could raise indoor relative humidities to unsafe levels, which could promote the growth of dust......-mites and mould. Controls may increase drying capacity by increasing ventilation airflow, but this may not be sufficient to limit moisture-related risks. This research investigated the added demand-control measure of reducing variable heat recovery to increase drying capacity when using an uncoated rotary heat...... in these rooms, and the overall average reduction in heat recovery was less than 3%. The combined measures only succeeded in living rooms and bedrooms, and the results confirmed that rotary heat exchangers should not be used in kitchens or bathrooms, where moisture risks may be unavoidable....

  8. A nodal model to predict vertical temperature distribution in a room with floor heating and displacement ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2013-01-01

    In this paper, the development of a nodal model that predicts vertical temperature distribution in a typical office room with floor heating and displacement ventilation (FHDV) is described. The vertical air flow distribution is first determined according to the principle of displacement ventilation.......5. The proposed vertical temperature distribution can be used in the design and analysis of hybrid systems with floor heating and displacement ventilation....

  9. Performance Comparison and Analysis of Heating and Ventilation of Two Kinds of Roof Solar Collectors

    Institute of Scientific and Technical Information of China (English)

    翟晓强; 王如竹; 代彦军

    2004-01-01

    Two roof solar collectors (RSCs), conventional single pass RSC and new double pass RSC, were compared. The new roof solar collector, which is formed by integrating a double pass solar air collector with the roof of the building, can be operated more efficiently for space heating in winter, and for natural ventilation in other seasons. To evaluate the performances of the two RSCs for both space heating and natural ventilation, a single traditional Chinese style house, on which the two RSCs will be mounted, was developed. The efficiency of solar energy conversion for the new RSC is higher than that of the single pass one by 10% on average, and the ventilation rate contributed by natural ventilation for the new RSC can be improved to a great extent for most cases, indicating that the new RSC is superior to the single pass one from the viewpoint of both space heating and natural ventilation. The new RSC is more potential for improving indoor thermal environment and energy saving of buildings.

  10. Dynamic model of counter flow air to air heat exchanger for comfort ventilation with condensation and frost formation

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Rose, Jørgen; Kragh, Jesper

    2009-01-01

    In cold climates heat recovery in the ventilation system is essential to reduce heating energy demand. Condensation and freezing occur often in efficient heat exchangers used in cold climates. To develop efficient heat exchangers and defrosting strategies for cold climates, heat and mass transfer...

  11. Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2013-01-01

    mixing ventilation systems was found. The next two tests simulated an office room during summer, ventilated and cooled either by a displacement ventilation system alone or by a displacement ventilation system combined with radiant floor cooling. Displacement ventilation combined with floor cooling had...... lower floor temperature, warmer supply air, and less homogeneous vertical temperature profile, but it did not result in thermal discomfort on feet/lower legs or discomfort due to a vertical air temperature difference higher than for a displacement ventilation system alone, where the floor temperature......Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation systems and radiant heating/cooling systems. In the first two tests, the simulated residential room was equipped either by a mixing ventilation system supplying warm air for space...

  12. Solutions for Energy Efficient and Sustainable Heating of Ventilation Air: A Review

    Directory of Open Access Journals (Sweden)

    A. Žandeckis

    2015-10-01

    Full Text Available A high energy efficiency and sustainability standards defined by modern society and legislation requires solutions in the form of complex integrated systems. The scope of this work is to provide a review on technologies and methods for the heating of ventilation air as a key aspect for high energy and environmental performance of buildings located in a cold climate. The results of this work are more relevant in the buildings where space heating consumes a significant part of the energy balance of a building, and air exchange is arranged in an organized manner. A proper design and control strategy, heat recovery, the use of renewable energy sources, and waste heat are the main aspects which must be considered for efficient and sustainable ventilation. This work focuses on these aspects. Air conditioning is not in the scope of this study.

  13. Experimental Investigation of Heat Transfer during Night-Time Ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Jensen, Rasmus Lund; Manz, H.

    2010-01-01

    is the heat transfer at the internal room surfaces. Increased convection is expected due to high air flow rates and the possibility of a cold air jet flowing along the ceiling, but the magnitude of these effects is hard to predict. In order to improve the predictability, heat transfer during night...

  14. Performance of Counter Flow Heat Recovery Ventilation Systems in Dwellings Considering the Influence of Uncertainties

    NARCIS (Netherlands)

    Yang, Z.; Cauberg, J.J.M.; Tenpierik, M.J.

    2012-01-01

    Both critical and optimistic claims have been made regarding the performance of heat recovery ventilation systems (HRVS) in dwellings. Such arguments are raised partly because two key aspects are not fully clarified, i.e. the performance criteria and the influence of uncertainties. In the current pa

  15. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  16. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  17. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  18. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  19. Transient natural ventilation of a room with a distributed heat source

    Science.gov (United States)

    Fitzgerald, Shaun D.; Woods, Andrew W.

    We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.

  20. Development of a plastic rotary heat exchanger for room-based ventilation in existing apartments

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2015-01-01

    for single-room ventilation based on thermal design theory. Performance is predicted from correlations of dimensionless groups for regenerative heat exchangers, and this guides the selection of a polycarbonate honeycomb with small circular channels. Experiments quantify flows and determine temperature...

  1. Control and prevention of ice formation and accretion on heat exchangers for ventilation systems

    DEFF Research Database (Denmark)

    Rahimi, Maral; Afshari, Alireza

    2015-01-01

    In cold climates, the application of mechanical ventilation systems with heat recovery like are airto-air exchangers is used for reducing energy consumption for heating buildings by transferring heat exhausted air to supply air. However, increase efficiency of heat exchanger results in lower...... exhaust air temperatures and Ice formation on heat exchanger fins, which can cause problem and is not favourable. Therefore, prevention and control of ice formation on heat exchangers is necessary. The existing methods are divided into two different methods: active and passive ice control methods....... The active methods are e.g. bypass, recirculation, preheating. The passive methods relate to the surface characteristics of the heat exchanger fins as they have effect on ice formation in initial phase. All these methods have varying levels of success, cost, and effectiveness, which are depending on the heat...

  2. MODELLING AND SIMULATION OF A SINGLE-ZONE HEATING AND VENTILATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Mesut ŞENGİRGİN

    2005-03-01

    Full Text Available In this study, modelling and simulation results of a single-zone heating and ventilation system of a large office room are introduced. Heating system is controlled by an on-off controller. By considering the sinusoidal outdoor air tempareture variation and various outdoor/return air ratios as input parameters, dynamic behaviour of room air tempereture are investigated. For this purpose, MATLAB/Simulink code is used.

  3. Floor heating and cooling combined with displacement ventilation: Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Causone, Francesco; Corgnati, Stefano P. [TEBE Research Group, Department of Energetics, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Baldin, Fabio [Department of Applied Physics, University of Padova, via Venezia 1, 35131 Padova (Italy); Olesen, Bjarne W. [ICIEE, Department of Civil Engineering, Technical University of Denmark, Nils Koppels Alle Building 402, 2800 Kgs. Lyngby (Denmark)

    2010-12-15

    Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase. Few studies on these topics were found in the literature. An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin. The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences. (author)

  4. Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Olesen, Bjarne W.

    Present work addresses the heating, cooling and ventilation concerns of the Technical University of Denmark’s house, Fold, for Solar Decathlon Europe 2012. Various innovative approaches are investigated, namely, utilization of ground, photo-voltaic/thermal (PV/T) panels and phase change materials...... by the embedded pipes which are coupled with the ground. Ventilation is mainly used to control the humidity and to remove sensory and chemical pollution. PV/T panels enable the house to be a “plus” energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively...

  5. A Literature Review on Heating of Ventilation Air with Large Diameter Earth Tubes in Cold Climates

    Directory of Open Access Journals (Sweden)

    Lili Tan

    2013-07-01

    Full Text Available Earth-air heat exchange (EAHE systems offer the possibility of reducing use of nonrenewable energy for heating ventilation air in cold climates. The number of installations of large diameter (greater than 900 mm EAHE systems reported for cold climates is small. Even less has been reported on their heating performance, but the available information suggests that further rigorous assessment is warranted to determine whether the reported better than expected temperature rise is supported and, if so, the reasons for this. Another concern is the possibility of long-term heat depletion in the surrounding soil, which would affect performance. Only a couple of short-term experimental studies of ground temperature effects of heating with EAHE were found for cool climates. Four articles that addressed ground temperature effects with horizontal ground source heat pump exchangers had conflicting findings regarding heat depletion in the soil.

  6. Analysis and Choice of Optimal Heating Ventilation Air Conditioning System for a Teaching Unit

    Directory of Open Access Journals (Sweden)

    Marina Verdeş

    2007-01-01

    Full Text Available Under the conditions of present society in which providing an optimum interior comfort is confronted with the necessity of the energy consumption reduction, solving this problem depends on the factors which contribute to the achievements of this comfort. Modern buildings -- implicitly teaching unit -- may be equipped with installations which have low energy consumption, respective a heating, cooling and ventilating integrated system with heat pumps system which can assure all the required comfort conditions. This paper underlines the necessity to use the heat pump in heating system for a teaching unit, energetic and economic guides and the possibility to increase them when using cooling and heating mixed. The solution of heat pumps for heating of the teaching unit and the energetic and economic advantages of the system is made in study.

  7. The conference of Russian Association of Engineers for Heating, Ventilation, Air-Conditioning, Heat Supply and Building Thermal Physics (ABOK

    Directory of Open Access Journals (Sweden)

    V.M. Yakubson

    2014-04-01

    Full Text Available On April, 11th, in Lenexpo the XVI conference of Russian Association of Engineers for Heating, Ventilation, Air-Conditioning, Heat Supply and Building Thermal Physics (ABOK “Effective HVAC and Heat Supply Systems” took place. There were a lot of presentations of new equipment for building systems and networks. All these reports were dedicated to the ways to make buildings more comfortable for people, to increase the energy efficiency, to reduce expenses and to improve the production efficiency. But besides the specific equipment, there were some reports dedicated to more general problems in design, installation and maintenance of building systems and networks

  8. Mechanical ventilation with heat recovery in arctic climate

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    pressure drop. Preheating the inlet air (outdoor air) to a temperature just above 0ºC is typically used to solve the problem. To minimize the energy cost, a more efficient solution to the problem is therefore desirable. In this project a new design of a heat recovery unit has been developed to the low......-energy house in Sisimiut, which is capable of continuously defrosting itself. The disadvantage of the unit is that it is quite big compared with other units. In this paper the new heat recovery unit is described and laboratory measurements are presented showing that the unit is capable of continuously...

  9. Advanced simulations of energy demand and indoor climate of passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University......In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunctional ventilation concept...... of Denmark. Through building integration in high performance offices the system is optimized to incorporate multiple functions like heating, cooling and ventilation, thus saving the expenses of separate cooling and heating systems. The simulation results are derived using the state-of-the-art building...

  10. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-09-01

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  11. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    DEFF Research Database (Denmark)

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele;

    2014-01-01

    Experience has shown that appropriate design of very low energy dwellings can be a large challenge and that the final design may result in insufficient heating in winter and overheating in summer. The 126 certified Passive House apartments (Ravnsborghusene) in Køge, Denmark are a low energy build...... with south oriented windows, static shadings by the balcony overhangs and low ventilation rates, resulted in excessive hours of overheating....

  12. Indoor Air Quality and Ventilation Strategies in the Use of Combustion Space Heating Appliances in Housing

    OpenAIRE

    Setiani, Onny

    1994-01-01

    Indoor air quality (IAQ) in the use of combustion appliances is important for adequate evaluation of air pollution health risks. Since people spend most of their time inside buildings, especially the elderly and children, their exposure to indoor air contaminants can increase health problems in the community. Combustion materials emitted from combustion space heating appliances in housing during the winter may become a serious problem to health, since sources of ventilation are usually left c...

  13. Gain control for solar wall heating with transparent insulation (TI) - requirements for cost effective application of natural ventilation in multifunctional and ventilated facades (MFVF)

    Energy Technology Data Exchange (ETDEWEB)

    Haller, A.; Althaus, H.J. [Ernst Schweizer AG, Hedingen (Switzerland); Platzer, W.J. [Fraunhofer Inst. for Solar Energy Systems, ISE, Freiburg (Germany); Goerdt, W. [PSE Projektgesellschaft Solare Energiesysteme mbH, Freiburg (Germany)

    2000-07-01

    This paper describes the potential of natural ventilation for solar wall heating systems with TI in order to avoid overheating in summer. Based on a commercial facade system two prototypes have been built with different absorber characteristics. The measurements on a outdoor test site showed that it is possible to reach an equivalent energy transmission value (g-value) as low as 15% in ventilated mode. In heating mode with sealed ventilation cavity the g-value reaches 48%. With a lime stone mass wall this yields to a system efficiency of 36% and an U-value below 1 W/m{sup 2}K. The variation of the absorber characteristics showed that is possible to reach higher solar gains in winter at the cost of higher g-values in summer. The optimum depends on the application and its tolerance to summer heat gains. The experiments did also confirm the demanding requirements for the ventilation valve construction in closed state: 140 deg. C maximum operating temperature, U-value of 1 W/m{sup 2}K, air tightness comparable to a low energy window. In ventilation state, a open area of 600 dm{sup 2} per meter width with low pressure drop is required. Unfortunately no systems or products are commercially available to fulfil these requirements. Thus, three concepts were further investigated for this application. Test showed that there will be more development and investment required for a commercial facade product. (au)

  14. Heat and hazardous contaminant transports in ventilated high-rise industrial halls

    Institute of Scientific and Technical Information of China (English)

    王沨枫; 刘志强; Christoph van Treeck; 王汉青; 唐文武; 寇广孝

    2015-01-01

    Performances and efficiencies of displacement ventilation (DV) and partial ventilation (PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8´1010, 1.0´1012 and 2.1´1012) and two values of source contaminant flux (5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2´104, 5´104, 1.5´105 and 4.5´105 for DV and 5´105, 1´106, 2´106 and 4´106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV atRe=1´106with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice whenRa=5.8´1010. However, DVs atRe=5´104andRe=1.5´105 with center-located sources and floor-mounted air suppliers are the best choices forRa=1.0´1012 andRa=2.1´1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls.

  15. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    Science.gov (United States)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  16. Wind- and stack-assisted mechanical ventilation with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    presented the outline of a heat recovery concept suitable for stack and wind-assisted mechanical ventilation systems with total system pressure losses of 74Pa. The heat recovery concept is based on two air-to-water exchangers connected by a liquid loop powered by a pump. The core element of the concept......, a prototype of a heat exchanger, was developed based on design criteria about pressure drop, eciency and production concerns. The exchanger is based on banks of plastic tubing cris-crossing the air flow, thus creating approximate counter flow between air and water. Round PE plastic tubing is used. The tubing...... fittings. Multiple design proposals were modeled and investigated to determine the optimal solution with respect to pressure drop, heat transfer, and production feasibility. Software models were developed to simulate the temperature distribution within the tube bank. The final design involves two parallel...

  17. Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su; Per FAHLEN; Torbj(o)rn LINDHOLM

    2007-01-01

    Ground-coupled heat pumps(GCHP) arecommonly used in residential heating system. To mitigatethe boreholes temperature dropping with operating time, anew exhaust-air recharging system is developed. The newrecharging system can be used in three operational modes.In this paper, a ground-coupled heat recovery ventilation(HRV) model is discussed. A thermal model is set up tofind the optimal brine flow rate and heat transfer allocationratio between exhaust and supply coils for maximum heatrecovery efficiency. Contrary to the conventional liquid-loopHRV systems, the brine temperature entering the exhaustcoil never goes blow zero(0℃), and hence defrosting isneedless in the ground-coupled HRV system. This can makethe ground-coupled HRV system over 20% more efficientthan a conventional HRV system at low outdoortemperatures.

  18. Air distribution in a multi-occupant room with mixing or displacement ventilation with or without floor or ceiling heating

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2015-01-01

    This study performed a comparative analysis of the air distribution in a multi-occupant room with mixing or displacement ventilation and the effect of adding floor or ceiling heating to each of them. The vertical distribution of indoor air temperature and velocity in the occupied zone......; the mean local turbulence intensity varied from 12.0% to 14.1% with mixing ventilation with or without floor or ceiling heating, and the corresponding values were 1.5°C to 2.5°C and 7.3% to 9.8% with displacement ventilation with or without floor or ceiling heating. Mean air distribution effectiveness...... varied from 0.93 to 1.0 for mixing ventilation and from 1.06 to 1.14 for displacement ventilation with or without floor or ceiling heating. The results are relevant to the design and control of mixing and displacement ventilation with or without floor or ceiling heating in a multi-occupant room....

  19. Ventilation loss and pressurization in the NASA launch/entry suit: Potential for heat stress

    Science.gov (United States)

    Kaufman, Jonathan W.; Dejneka, Katherine Y.; Askew, Gregory K.

    1989-01-01

    The potential of the NASA Launch/Entry Suit (LES) for producing heat stress in a simulated Space Shuttle cabin environment was studied. The testing was designed to identify potential heat stress hazards if the LES were pressurized or if ventilation were lost. Conditions were designed to simulate an extreme pre-launch situation with chamber temperatures maintained at dry bulb temperature = 27.2 +/- 0.1 C, globe temperature = 27.3 +/- 0.1 C, and wet bulb temperature = 21.1 +/- 0.3 C. Two females and two males, 23 to 34 years of age, were employed in this study, with two subjects having exposures in all 3 conditions. Test durations in the ventilated (V) and unventilated (UV) conditions were designed for 480 minutes, which all subjects achieved. Pressurized runs (Pr) were designed for 45 minutes, which all subjects also achieved. While some significant differences related to experimental conditions were noted in rectal and mean skin temperatures, evaporation rates, sweat rates, and heart rate, these differences were not thought to be physiologically significant. The results indicate that the LES garment, in either the Pr or UV state, poses no danger of inducing unacceptable heat stress under the conditions expected within the Space Shuttle cabin during launch or reentry.

  20. Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test

    Directory of Open Access Journals (Sweden)

    Ludovico Danza

    2016-01-01

    Full Text Available The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a centrifugal extractor for the air circulation. The latter is equipped with a dynamic window with ventilated and blinded double-glazing provided with a heat exchanger. The connection of the dynamic window and heat recovery unit provides different actions: heat recovery; heat transfer reduction; pre-heating before the exchanger. Different operating configurations allowed the trends of the dynamic system to be assessed in different seasons in terms of energy saving, thermal comfort behavior and energy efficiency. The results showed an overall lower consumption of the innovative system, both in winter and summer, with 20% and 15% energy saving, respectively. In general, the dynamic system provided the best comfort conditions, even if it involves a worse behavior than expected, in the summer season.

  1. Cost-Effectiveness Analysis of Heat and Moisture Exchangers in Mechanically Ventilated Critically Ill Patients

    Science.gov (United States)

    Menegueti, Mayra Goncalves; Auxiliadora-Martins, Maria; Nunes, Altacilio Aparecido

    2016-01-01

    Background Moisturizing, heating and filtering gases inspired via the mechanical ventilation (MV) circuits help to reduce the adverse effects of MV. However, there is still no consensus regarding whether these measures improve patient prognosis, shorten MV duration, decrease airway secretion and lower the incidence of ventilator associated pneumonia (VAP) and other complications. Objectives The aim of this study was to study the incremental cost-effectiveness ratio associated with the use of heat and moisture exchangers (HME) filter to prevent VAP compared with the heated humidifiers (HH) presently adopted by intensive care unit (ICU) services within the Brazilian Healthcare Unified System. Patients and Methods This study was a cost-effectiveness analysis (CEA) comparing HME and HH in preventing VAP (outcome) in mechanically ventilated adult patients admitted to an ICU of a public university hospital. Results The analysis considered a period of 12 months; MV duration of 11 and 12 days for patients in HH and HME groups, respectively and a daily cost of R$ 16.46 and R$ 13.42 for HH and HME, respectively. HME was more attractive; costs ranged from R$ 21,000.00 to R$ 22,000.00 and effectiveness was close to 0.71, compared with a cost of R$ 30,000.00 and effectiveness between 0.69 and 0.70 for HH. HME and HH differed significantly for incremental effectiveness. Even after an effectiveness gain of 1.5% in favor of HH, and despite the wide variation in the VAP rate, the HME effectiveness remained stable. The mean HME cost-effectiveness was lower than the mean HH cost-effectiveness, being the HME value close to R$ 44,000.00. Conclusions Our findings revealed that HH and HME differ very little regarding effectiveness, which makes interpretation of the results in the context of clinical practice difficult. Nonetheless, there is no doubt that HME is advantageous. This technology incurs lower direct cost. PMID:27843770

  2. Talaromyces rubrifaciens, a new species discovered from heating, ventilation and air conditioning systems in China.

    Science.gov (United States)

    Luo, Yi; Lu, Xiaohong; Bi, Wu; Liu, Fan; Gao, Weiwei

    2016-01-01

    A new Talaromyces species, T. rubrifaciens, was isolated from supply air outlets of heating, ventilation and air conditioning (HVAC) systems in three kinds of public building in Beijing and Nanjing, China. Morphologically it exhibits many characters of section Trachyspermi but is distinguished from other species of this section by restricted growth and broad and strictly biverticillate conidiophores. Phylogenetic analyses based on the internal transcribed spacer rDNA (ITS), β-tubulin (BenA), calmodulin (CaM) and RNA polymerase second largest subunit (RPB2) genes reveal that T. rubrifaciens is a distinct species in section Trachyspermi. © 2016 by The Mycological Society of America.

  3. Advanced simulations of energy demand and indoor climate of passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...

  4. Repeated exposure to heat stress results in a diaphragm phenotype that resists ventilator-induced diaphragm dysfunction.

    Science.gov (United States)

    Yoshihara, Toshinori; Ichinoseki-Sekine, Noriko; Kakigi, Ryo; Tsuzuki, Takamasa; Sugiura, Takao; Powers, Scott K; Naito, Hisashi

    2015-11-01

    Controlled mechanical ventilation (CMV) is a life-saving intervention for patients in respiratory failure. Unfortunately, prolonged mechanical ventilation (MV) results in diaphragmatic atrophy and contractile dysfunction, both of which are predicted to contribute to problems in weaning patients from the ventilator. Therefore, developing a strategy to protect the diaphragm against ventilator-induced weakness is important. We tested the hypothesis that repeated bouts of heat stress result in diaphragm resistance against CMV-induced atrophy and contractile dysfunction. Male Wistar rats were randomly divided into six experimental groups: 1) control; 2) single bout of whole body heat stress; 3) repeated bouts of whole body heat stress; 4) 12 h CMV; 5) single bout of whole body heat stress 24 h before CMV; and 6) repeated bouts of whole body heat stress 1, 3, and 5 days before 12 h of CMV. Our results revealed that repeated bouts of heat stress resulted in increased levels of heat shock protein 72 in the diaphragm and protection against both CMV-induced diaphragmatic atrophy and contractile dysfunction at submaximal stimulation frequencies. The specific mechanisms responsible for this protection remain unclear: this heat stress-induced protection against CMV-induced diaphragmatic atrophy and weakness may be partially due to reduced diaphragmatic oxidative stress, diminished activation of signal transducer/transcriptional activator-3, lower caspase-3 activation, and decreased autophagy in the diaphragm.

  5. Effect of heat and moisture exchangers on the prevention of ventilator-associated pneumonia in critically ill patients.

    Science.gov (United States)

    Auxiliadora-Martins, M; Menegueti, M G; Nicolini, E A; Alkmim-Teixeira, G C; Bellissimo-Rodrigues, F; Martins-Filho, O A; Basile-Filho, A

    2012-12-01

    Ventilator-associated pneumonia (VAP) remains one of the major causes of infection in the intensive care unit (ICU) and is associated with the length of hospital stay, duration of mechanical ventilation, and use of broad-spectrum antibiotics. We compared the frequency of VAP 10 months prior to (pre-intervention group) and 13 months after (post-intervention group) initiation of the use of a heat and moisture exchanger (HME) filter. This is a study with prospective before-and-after design performed in the ICU in a tertiary university hospital. Three hundred and fourteen patients were admitted to the ICU under mechanical ventilation, 168 of whom were included in group HH (heated humidifier) and 146 in group HME. The frequency of VAP per 1000 ventilator-days was similar for both the HH and HME groups (18.7 vs 17.4, respectively; P = 0.97). Duration of mechanical ventilation (11 vs 12 days, respectively; P = 0.48) and length of ICU stay (11 vs 12 days, respectively; P = 0.39) did not differ between the HH and HME groups. The chance of developing VAP was higher in patients with a longer ICU stay and longer duration of mechanical ventilation. This finding was similar when adjusted for the use of HME. The use of HME in intensive care did not reduce the incidence of VAP, the duration of mechanical ventilation, or the length of stay in the ICU in the study population.

  6. Modelling the heat dynamics of building integrated and ventilated photovoltaic modules

    DEFF Research Database (Denmark)

    Friling, N.; Jimenez, M.J.; Bloem, H.

    2009-01-01

    -up. To identify best set-up, grey-box models consisting of stochastic differential equations are applied. The models are first order stochastic state space models. Maximum likelihood estimation and the extended Kalman filter are applied in the parameter estimation phase. To validate the estimated models, plots......This paper deals with mathematical modelling of the heat transfer of building integrated photovoltaic (BIPV) modules. The efficiency of the photovoltaic (PV) module and its temperature are negatively correlated. It is therefore of interest to lower the temperature of the PV module by increasing...... the heat transfer from the PV module. The experiment and data originate from a test reference module the EC-JRC Ispra. The set-up provides the opportunity of changing physical parameters, the ventilation speed and the type of air flow, and this makes it possible to determine the preferable set...

  7. Experimental study of air distribution and ventilation effectiveness in a room heated by warm air and/or floor heating

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.; Krajčík, Michal

    2010-01-01

    The levels of required ventilation depend on the criteria for indoor air quality in existing standards and guidelines. On top of that, the resulting ventilation in air changes per hour is depending on the ventilation effectiveness. In the standard CR 1752 the recommended values for ventilation...

  8. Demonstration of the Performance of an Air-Type Photovoltaic Thermal (PVT System Coupled with a Heat-Recovery Ventilator

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2016-09-01

    Full Text Available A heat-recovery ventilator (HRV effectively conducts ventilation by recovering waste heat from indoors to outdoors during heating periods. However, dew condensation associated with the HRV system may arise due to the difference between the indoor temperature and the very low outdoor temperature in winter, and this can decrease the heat exchange efficiency. These problems can be solved by the pre-heating of the incoming air, but additional energy is required when pursuing such a strategy. On the other hand, an air-type photovoltaic thermal (PVT system produces electricity and thermal energy simultaneously using air as the heat transfer medium. Moreover, the heated air from the air-type PVT system can be connected to the HRV to pre-heat the supply air instead of taking in the cold outdoor air. Thus, the ventilation efficiency can be improved and the problems arising during the heating period can be resolved. Consequentially, the heating energy required in a building can be reduced, with additional electricity acquired as well. In this paper, the performance of an air-type PVT system coupled with an HRV is assessed. To do this, air-type PVT collectors operating at 1 kWp were installed in an experimental house and coupled to an HRV system. Thermal performance and heating energy required during the winter season were analyzed experimentally. Furthermore, the electrical performances of the air-type PVT system with and without ventilation at the back side of the PV during the summer season were analyzed.

  9. Computational fluid dynamics simulation of an earth-air heat exchanger for ventilation system

    Science.gov (United States)

    Raczkowski, Andrzej; Suchorab, Zbigniew; Czechowska-Kosacka, Aneta

    2017-07-01

    Directive 2010/31/EU (EPBD Recast) obligates European Union members to improve energetic performance of the buildings. One of the crucial standards of energy-saving buildings are the passive houses, which are characterized by annual maximum space heating below 15 kWh/(m2.a) and the use of the specific primary energy for all domestic applications (also heating, hot water production and electricity) below 120 kWh/(m2.a). To achieve this standard there should be applied the solutions based on ground energy acquisition. One of them is the earth-air heat exchanger (EAHC) for ventilation systems. The article presents numerical simulations conducted by solving partial differential equations for three dimensional heat transfer. For the simulations it was applied Computational Fluid Dynamics (CFD) technique. The efficiency of EAHC was considered under different values of external temperature during the winter period (from -24 to -8 °C). Obtained results prove linear correlation with calculations of EAHC according to standards of the Polish National Energy Conservation Agency (NAPE). The slope of regression between outlet temperatures calculated with CFD model and NAPE standards, equals 0.59 which means, that according the CFD model, the efficiency of the exchanger is lower.

  10. Heat transfer on a naturally cross-driven ventilated triangular cavity with openings

    Energy Technology Data Exchange (ETDEWEB)

    Berli, M E; Saita, F A [INTEC, Universidad Nacional del Litoral, Gueemes 3450, 3000, Santa Fe (Argentina); Paolo, J Di, E-mail: mberli@santafe-conicet.gov.a [GIMEF, Departamento IngenierIa Industrial, FRSF - UTN, Lavaise 610, 3000, Santa Fe (Argentina)

    2009-05-01

    This work addresses the problem of heat transfer through the roof of a family home with the purpose of improving air-conditioning energy savings during hot summer days. To this end, the air natural convection in a right-angle triangular cavity, resembling an attic, is numerically analyzed. The air cavity is assumed as naturally ventilated through two openings that induce an external air-stream flowing into and out of the cavity. The governing equations for both flow and heat transfer are simultaneously solved with appropriate boundary conditions. Finite element technique is employed to transform the original set of differential equations into a non-linear discrete one, which is finally solved by Newton iteration. Two major assumptions are made, namely: radiation heat transfer is negligible and the air flow is in laminar regime; in addition, the usual Boussinesq approximation is employed. Under these assumptions the numerical predictions show that the amount of heat transferred through the ceiling rapidly diminishes as the flow through the cavity increases. Therefore; whether or not the ceiling is insulated, the energy transfer is reduced by more than 50% and energy savings are considerably improved.

  11. Viscous heating effect on deactivation of helminth eggs in ventilated improved pit sludge.

    Science.gov (United States)

    Belcher, D; Foutch, G L; Smay, J; Archer, C; Buckley, C A

    2015-01-01

    Viscous heating by extrusion of faecal material obtained from ventilated improved pit (VIP) latrines can be used to deactivate soil-transmitted helminth (STH) eggs by increasing the temperature of faecal sludge uniformly. Viscous heating can deactivate STH eggs present in sludge to make the material safer to transport, dispose of, or use in agricultural applications or as an energy source. The mechanical energy required to generate the shear rate can originate from any source. No other heat source or additive is required. Here we determined a baseline for the deactivation of STH eggs using viscous heating. To characterize equipment performance, three parameters were investigated: (1) minimum temperature required for deactivation; (2) local maximum temperatures for various flow rates and moisture contents (MCs); and (3) thermal efficiency. Excess water is undesirable since low viscosities require extended residence time and increased energy input. The minimum temperature to achieve greater than 90% helminth egg deactivation is 70 °C. For the laboratory-scale equipment tested, the maximum allowable mass flow rate for VIP sludge with 77% MC was found to be 3.6 g/s.

  12. HVAC (heating, ventilation, air conditioning) literature in Japan: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Hane, G.J.

    1988-02-01

    Japanese businessmen in the heating, ventilation, air conditioning, and refrigeration (HVACandR) industry consider the monitoring of technical and market developments in the United States to be a normal part of their business. In contrast, efforts by US businessmen to monitor Japanese HVAC and R developments are poorly developed. To begin to redress this imbalance, this report establishes the groundwork for a more effective system for use in monitoring Japanese HVAC and R literature. Discussions of a review of the principal HVAC and R publications in Japan and descriptions of the type of information contained in each of those publications are included in this report. Since the Japanese HVAC and R literature is abundant, this report also provides practical suggestions on how a researcher or research manager can limit the monitoring effort to the publications and type of information that would most likely be of greatest value.

  13. Mesoscopic Study of a Square Cavity Ventilated and heated by the bottom

    Science.gov (United States)

    Bouayed, Z. E.; Houat, S.

    2017-03-01

    In this paper, we present a numerical study of the laminar mixed convection in a ventilated cavity square; one of the walls is subjected to a constant temperature, while the other walls are considered adiabatic. The thermal lattice Boltzmann method with the double population model was used. A computer code was developed with the D2Q9 model for the velocity field and D2Q5 for the temperature field to determine the whole structure of the flow. The results are presented in the form of thermal fields for the Richardson number Ri = 10. Those show that each time the Richardson number increases, the number of Nusselt increases too what justifies an increase in the heat transfer.

  14. Thermal analysis of both ventilated and full disc brake rotors with frictional heat generation

    Directory of Open Access Journals (Sweden)

    Belhocine A.

    2014-06-01

    Full Text Available In automotive engineering, the safety aspect has been considered as a number one priority in development of a new vehicle. Each single system has been studied and developed in order to meet safety requirements. Instead of having air bags, good suspension systems, good handling and safe cornering, one of the most critical systems in a vehicle is the brake system. The objective of this work is to investigate and analyze the temperature distribution of rotor disc during braking operation using ANSYS Multiphysics. The work uses the finite element analysis techniques to predict the temperature distribution on the full and ventilated brake discs and to identify the critical temperature of the rotor. The analysis also gives us the heat flux distribution for the two discs.

  15. A New Method to Design Cam Used in Automobile Heating, Ventilating and Cooling System

    Science.gov (United States)

    Singh, B.; Singh, D.; Saini, J. S.

    2012-10-01

    With the automotive air-conditioning industry aiming at better levels of quality, cost effectiveness and short time to market, the need for simulation is at an all time high. In the present study, the airflow control mechanism of an automotive heating, ventilating and cooling module for opening various doors/dampers were kinematically analyzed. A new method for cam design was developed which is faster and simpler than the existing oscillating link method. The existing design was modified for the same output using the new cam design method. It is shown that the torque required in the modified design is lesser than that in the existing design, thus lowering the effort required to rotate the cam from the control panel.

  16. Homologous recombination preferentially repairs heat-induced DNA double-strand breaks in mammalian cells.

    Science.gov (United States)

    Takahashi, Akihisa; Mori, Eiichiro; Nakagawa, Yosuke; Kajihara, Atsuhisa; Kirita, Tadaaki; Pittman, Douglas L; Hasegawa, Masatoshi; Ohnishi, Takeo

    2016-11-13

    Heat shock induces DNA double-strand breaks (DSBs), but the precise mechanism of repairing heat-induced damage is unclear. Here, we investigated the DNA repair pathways involved in cell death induced by heat shock. B02, a specific inhibitor of human RAD51 (homologous recombination; HR), and NU7026, a specific inhibitor of DNA-PK (non-homologous end-joining; NHEJ), were used for survival assays of human cancer cell lines with different p53-gene status. Mouse embryonic fibroblasts (MEFs) lacking Lig4 (NHEJ) and/or Rad54 (HR) were used for survival assays and a phosphorylated histone H2AX at Ser139 (γH2AX) assay. MEFs lacking Rad51d (HR) were used for survival assays. SPD8 cells were used to measure HR frequency after heat shock. Human cancer cells were more sensitive to heat shock in the presence of B02 despite their p53-gene status, and the effect of B02 on heat sensitivity was specific to the G2 phase. Rad54-deficient MEFs were sensitive to heat shock and showed prolonged γH2AX signals following heat shock. Rad51d-deficient MEFs were also sensitive to heat shock. Moreover, heat shock-stimulated cells had increased HR. The HR pathway plays an important role in the survival of mammalian cells against death induced by heat shock via the repair of heat-induced DNA DSBs.

  17. Nasal high-frequency oscillatory ventilation impairs heated humidification: A neonatal bench study.

    Science.gov (United States)

    Ullrich, Tim L; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik S

    2017-09-07

    Nasal high-frequency oscillatory ventilation (nHFOV) is a novel mode of non-invasive ventilation used in neonates. However, upper airway obstructions due to viscous secretions have been described as specific adverse effects. We hypothesized that high-frequency oscillations reduce air humidity in the oropharynx, resulting in upper airway desiccation. Therefore, we aimed to investigate the effects of nHFOV ventilatory settings on oropharyngeal gas conditions. NHFOV or nasal continuous positive airway pressure (nCPAP) was applied, along with heated humidification, to a previously established neonatal bench model that simulates oropharyngeal gas conditions during spontaneous breathing through an open mouth. A digital thermo-hygro sensor measured oropharyngeal temperature (T) and humidity at various nHFOV frequencies (7, 10, 13 Hz), amplitudes (10, 20, 30 cmH2 O), and inspiratory-to-expiratory (I:E) ratios (25:75, 33:66, 50:50), and also during nCPAP. Relative humidity was always >99%, but nHFOV resulted in lower mean T and absolute humidity (AH) in comparison to nCPAP (P frequency and increasing nHFOV amplitude caused a decline in T and AH (P frequency of 7 Hz and an amplitude of 30 cmH2 O (T 32.4 ± 0.3°C, AH 34.7 ± 0.5 g · m(-3) ). Increasing the I:E ratio also reduced T and AH (P = 0.03). Intensified nHFOV settings with low frequencies, high amplitudes, and high I:E ratios may place infants at an increased risk of upper airway desiccation. Future studies should investigate strategies to optimize heated humidification during nHFOV. © 2017 Wiley Periodicals, Inc.

  18. Ventilation Loss in the NASA Space Shuttle Crew Protective Garments: Potential for Heat Stress

    Science.gov (United States)

    Askew, Gregory K.; Kaufman, Jonathan W.

    1991-01-01

    The potential of the National Aeronautics and Space Administration (NASA) S1035 Launch/Entry suit (LES) for producing heat stress in a simulated Space Shuttle cabin environment has been studied. The testing was designed to determine if the NASA S1035 poses a greater threat of inducing heat stress than the NASA S1032. Conditions were designed to simulate an extreme prelaunch situation, with chamber temperatures maintained at dry bulb temperature 27.2 +/- 0.1 C, globe temperature - 27.3 +/- 0.1 C, and wet bulb temperature 21.1 +/- 0.3 C. Four males, aged 28-48, were employed in this study, with three subjects having exposures in all four conditions and the fourth subject exposed to 3 conditions. Test durations in the ventilated (V) and unventilated (UV) conditions were designed for 480 minutes, which all subjects achieved. No significant differences related to experimental conditions were noted in rectal temperatures, heart rates or sweat rates. The results indicate that the S1032 and S1035 garments, in either the V or UV state, poses no danger of inducing unacceptable heat stress under the conditions expected within the Shuttle cabin during launch or re-entry.

  19. Experimental study of the heat transfers and passive cooling potential of a ventilated plenum designed for uniform air distribution

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Lessing, Julian

    2016-01-01

    suspended ceiling to uniformly distribute the supply air to the occupied zone. This, in effect, increases the thermal mass of the room because the upper slab of the room no longer is isolated from the occupied zone. In this study, the cooling potential of a diffuse ceiling ventilation system...... is investigated by experiments focused toward characterizing the convective heat transfer of the plenum. The heat transfers are quantified from four different air flow rates, the temperature of the air supplied to the plenum and the mean surface temperature, i.e. the total heat transfer coefficient of the plenum...... with unventilated plenum. In conclusion this study disclosed the mean heat transfer of the plenum with an inlet jet of approx. 1.2-0.4 m/s and temperature differences of 0.5-4.5 °C and showed that ventilation supply through the plenum can be used to augment the night cooling potential....

  20. Ventilated facade systems classification. Influence of ”Thermal bridges” on their heat-resistant characteristics (rus

    Directory of Open Access Journals (Sweden)

    Protasevich A.M.

    2011-12-01

    Full Text Available There are currently a large number of ventilated facade system (VFS designs for thermal insulation of exterior walls. At the same time structures are greatly varied by the way of interlayer ventilation, type of insulation protection from the filtration air flow, thermal protection level with the equal thickness of heat insulation material, etc.In this article the VFS thermal insulation structures were analyzed. The main problems of designing such systems are protection of thermal insulation layer from cold filtration air flow and reducing heat transfer resistance by reason of heat-conducting inclusions (e.g. metal fixings. The possible technical decisions for both questions are found.On the basis of field and laboratory researches a classification system is proposed. External walls heat transfer resistance calculations of a real object with a vented insulation system were carried out.

  1. Simulation of coal low-temperature oxidation heating process in gob with “U+L” ventilation

    Directory of Open Access Journals (Sweden)

    Zhou Pei Ling

    2016-01-01

    Full Text Available In a gob with U + L ventilation, a tail roadway exists, which has important effects on the oxidation heating process and gas concentration in gob areas. Research on the heating process and gas concentration in the “U+L” ventilation can provide the basis for the prevention of spontaneous combustion, thus, the regularities of the oxidation heating process and gas concentration in gob areas were researched by simulation. Results showed that compared with U ventilation, U + L ventilation caused the high temperature zone and high temperature points in the gob areas to increase in depth and width and to be influenced by the distance between the crossheading of the tail roadway and workface. The heating rate of the high-temperature point in the gob with tail roadway was 1.5 times of that in gob without tail roadway, but was unaffected by the location of the tail roadway. Tail roadway had diversion effects on the airflow, especially near return side and the maximum reduction of gas concentration can be 0.36%.

  2. Ontology for Life-Cycle Modeling of Heating, Ventilating, and Air Conditioning (HVAC) Systems: Experimental Applications Using Revit

    Science.gov (United States)

    2012-03-01

    Center, Construction Engineering Research Laboratory (ERDC-CERL) has developed a core life- cycle building information model ( BIM ) based on three...was to promote consistency and quality of content created for Building Information Models ( BIMs ) across various disciplines. The HVAC MVD was...MVD. 15. SUBJECT TERMS building information modeling ( BIM ), ontology, Army facilities, heating, ventilating, and air-conditioning (HVAC) systems

  3. Vocal Ergonomics in the Workplace: Heating, Ventilation, and Air-Conditioning Method Influences on Vocal Comfort and Function

    Science.gov (United States)

    Sandage, Mary J.; Rahn, Keith A.; Smith, Audrey G.

    2017-01-01

    Purpose: The purpose of this study was to examine the influence of the heating, ventilation, and air-conditioning method on voice function following a voicing task using ecologically valid offices, one with radiant HVAC and one with forced air. Method: A total of 12 consented participants (6 women, 6 men) narrated a video in each of 4…

  4. Ventilation Model

    Energy Technology Data Exchange (ETDEWEB)

    V. Chipman

    2002-10-05

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their post-closure analyses. The Ventilation Model report was initially developed to analyze the effects of preclosure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts, and to provide heat removal data to support EBS design. Revision 00 of the Ventilation Model included documentation of the modeling results from the ANSYS-based heat transfer model. The purposes of Revision 01 of the Ventilation Model are: (1) To validate the conceptual model for preclosure ventilation of emplacement drifts and verify its numerical application in accordance with new procedural requirements as outlined in AP-SIII-10Q, Models (Section 7.0). (2) To satisfy technical issues posed in KTI agreement RDTME 3.14 (Reamer and Williams 2001a). Specifically to demonstrate, with respect to the ANSYS ventilation model, the adequacy of the discretization (Section 6.2.3.1), and the downstream applicability of the model results (i.e. wall heat fractions) to

  5. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

  6. Numerical Studies on Heat Release Rate in Room Fire on Liquid Fuel under Different Ventilation Factors

    Directory of Open Access Journals (Sweden)

    N. Cai

    2012-01-01

    Full Text Available Heat release rate (HRR of the design fire is the most important parameter in assessing building fire hazards. However, HRR in room fire was only studied by computational fluid dynamics (CFD in most of the projects determining fire safety provisions by performance-based design. In contrast to ten years ago, officers in the Far East are now having better knowledge of CFD. Two common questions are raised on CFD-predicted results on describing free boundaries; and on computing grid size. In this work, predicting HRR by the CFD model was justified with experimental room pool fire data reported earlier. The software fire dynamics simulator (FDS version 5 was selected as the CFD simulation tool. Prescribed input heating rate based on the experimental results was used with the liquid fuel model in FDS. Five different free boundary conditions were investigated to predict HRR. Grid sensitivity study was carried out using one stretched mesh and multiple uniform meshes with different grid sizes. As it is difficult to have the entire set of CFD predicted results agreed with experiments, macroscopic flow parameters on the mass flow rate through door opening predicted by CFD were also justified by another four conditions with different ventilation factors.

  7. Dose maintenance for Partial Liquid Ventilation: passive heat-and-moisture exchangers.

    Science.gov (United States)

    Nugent, L J; Mazzoni, M C; Flaim, S F; Hoffman, J K; Sekins, K M

    1999-01-01

    Partial Liquid Ventilation (PLV), a promising method for the treatment of acute lung failure, has been evaluated in many animal studies. It has recently progressed to the point of controlled clinical trials in which patients of all ages on conventional mechanical ventilation (CMV) have their lungs substantially filled with a perfluorochemical (PFC) liquid, perflubron (PFB). During PLV, it is desirable to both maintain humidification and minimize the evaporation of PFB in order to maintain a desired dose in the lung and to reduce dose consumption and redosing effort. Heat-and-moisture exchangers (HMEs) have been used for years as a passive means of minimizing water vapor loss from the respiratory tract during CMV support of intensive care and surgical patients. In the current study, research was undertaken to leverage the operating principles of existing HMEs such that specialized "fluorophilic" HMEs (FHMEs), devices optimized for both water and PFB conservation, could be realized. A patient simulator (involving both water vapor and PFB vapor sources) was constructed and used in the in-vitro evaluation of various FHME concepts. Dose-retention efficiencies were determined with the aid of an infrared instrument and a digital thermohygrometer. Although no larger than commercial HMEs in terms of dead space (gas-occupying volume), efficient FHMEs resulted, offering less flow resistance (delta P) than their commercial counterparts. Additionally, the presence of PFB vapor did not appear to compromise the water-exchange efficiency of certain HME configurations. One promising FHME design was also tested in swine undergoing 12-hour PLV treatments. A mean conservation efficiency of 63% at an average tidal volume of 550 mL was shown, although somewhat lower efficiencies may result in adult patients because efficiency was found to trend downward with increasing tidal volume. The use of an FHME is expected to sustain dose levels in patients for longer periods with less frequent

  8. Development of energy economic ventilation system with heat recovery in dwellings; Udvikling af energioekonomisk ventilationsloesning med varmegenvinding til boliger

    Energy Technology Data Exchange (ETDEWEB)

    Drivsholm, C.; Olsen, Hans; Groenborg Larsen, C.; Jensen, John Steen; Rammer Nielsen, T.; Kragh, J.; Svendsen, Svend

    2005-07-01

    This report describes and documents the development of a counter flow heat exchanger with efficiency of approximately 90% and a highly efficient axial fan both developed for small mechanical ventilation systems for use in single family houses. The report also treats problems concerning condensation and ice formation in efficient counter flow heat exchangers. The influence of condensate and ice is investigated by measurements on an efficient heat exchanger and different strategies for de-icing are tested. A computer program is developed to calculate how condensation and frost influence the heat exchange under stationary conditions. In the project a counter flow heat exchanger of aluminium is developed with a calculated efficiency of approximately 90%. The heat exchanger is hereby legal for ventilation of more than one fire section. CAD drawings of the exchanger are coded to a CNC milling machine and two cylinders (a positive and a negative mould) are produced. The joints of the heat exchanger are glued and placed in a protecting aluminium frame. (BA)

  9. Analysis of a heat recovery ventilation system in an nZEB building

    Energy Technology Data Exchange (ETDEWEB)

    Tissot, Anne; Michal, Herve [CETIAT, Centre Technique des Industries Aerauliques et Thermiques, Villeurbanne (France)

    2012-07-01

    CETIAT analysed on a monthly basis the measurement results for the parameters related to the ventilation system operation such as indoor air quality, thermal comfort, energy consumption, energy saving contribution and the influence of user behaviour. This analysis was performed in combination with several on site measurement campaigns of air flow rates and system air tightness in order to characterise in depth the real operation of the ventilation system. In general a very good level of indoor air quality and thermal comfort was maintained throughout the year. The study concludes with proposing concepts to realise further energy savings like demand controlled ventilation and ground loop ventilation. (orig.)

  10. Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.

    Science.gov (United States)

    Stephens, B; Siegel, J A

    2013-12-01

    This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M.A.; D.A. Springer

    2008-06-18

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the

  12. Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Clark, J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

  13. Optimization and Performance Study of Select Heating Ventilation and Air Conditioning Technologies for Commercial Buildings

    Science.gov (United States)

    Kamal, Rajeev

    Buildings contribute a significant part to the electricity demand profile and peak demand for the electrical utilities. The addition of renewable energy generation adds additional variability and uncertainty to the power system. Demand side management in the buildings can help improve the demand profile for the utilities by shifting some of the demand from peak to off-peak times. Heating, ventilation and air-conditioning contribute around 45% to the overall demand of a building. This research studies two strategies for reducing the peak as well as shifting some demand from peak to off-peak periods in commercial buildings: 1. Use of gas heat pumps in place of electric heat pumps, and 2. Shifting demand for air conditioning from peak to off-peak by thermal energy storage in chilled water and ice. The first part of this study evaluates the field performance of gas engine-driven heat pumps (GEHP) tested in a commercial building in Florida. Four GEHP units of 8 Tons of Refrigeration (TR) capacity each providing air-conditioning to seven thermal zones in a commercial building, were instrumented for measuring their performance. The operation of these GEHPs was recorded for ten months, analyzed and compared with prior results reported in the literature. The instantaneous COPunit of these systems varied from 0.1 to 1.4 during typical summer week operation. The COP was low because the gas engines for the heat pumps were being used for loads that were much lower than design capacity which resulted in much lower efficiencies than expected. The performance of equivalent electric heat pump was simulated from a building energy model developed to mimic the measured building loads. An economic comparison of GEHPs and conventional electrical heat pumps was done based on the measured and simulated results. The average performance of the GEHP units was estimated to lie between those of EER-9.2 and EER-11.8 systems. The performance of GEHP systems suffers due to lower efficiency at

  14. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...

  15. Silver zeolite antimicrobial activity in aluminium heating, ventilation and air conditioning system ducts.

    Science.gov (United States)

    Rizzetto, R; Mansi, A; Panatto, D; Rizzitelli, E; Tinteri, C; Sasso, T; Gasparini, R; Crovari, P

    2008-03-01

    Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty. The growing use of air-conditioning systems in many public and private buildings aggravates this health risk, especially when these systems are not correctly installed or regularly serviced. The aim of our study was to verify the capacity of Ag+ ions to stop the growth of bacteria and moulds inside the ducts of Heating, Ventilation and Air Conditioning system ducts (HVAC) systems when these ducts were lined with active Ag+ ions zeolite-coated panels. A Y-shaped HVAC model with two branches was used; one branch was made of traditional galvanized iron, as was the whole system, while the other was lined with active Ag+ zeolite-coated polyurethane panels. During the test, samples of dust present inside both ducts were collected and seeded in liquid and solid media to detect bacteria and moulds. The presence of bacteria was also sought in the air emerging from the outlets of both ducts. Tests made on samples of particulate collected from the two different ducts revealed a lower total bacterial load in the samples collected from the Ag+ zeolite-coated duct than in the samples from the traditional Zn galvanized duct. In addition, the values of bacterial load found in the air emerging from the Ag+ ions zeolite-lined duct were 5 times lower than those found in the air from the traditional galvanized iron duct. The utilization of Ag+ zeolite-coated panels in air-conditioning systems could improve the quality of the emerging air in comparison with traditional installations in galvanized iron. This innovation could prove particularly advantageous in the event of accidents during the installation of air-conditioning systems or of contaminated aerosols coming from outside.

  16. Are specialized endotracheal tubes and heat-and-moisture exchangers cost-effective in preventing ventilator associated pneumonia?

    Science.gov (United States)

    Gentile, Michael A; Siobal, Mark S

    2010-02-01

    Ventilator-associated pneumonia (VAP) is a common and serious complication of mechanical ventilation via an artificial airway. As with all nosocomial infections, VAP increases costs, morbidity, and mortality in the intensive care unit (ICU). VAP prevention is a multifaceted priority of the intensive care team, and can include the use of specialized artificial airways and heat-and-moisture exchangers (HME). Substantial evidence supports the use of endotracheal tubes (ETTs) that allow subglottic suctioning; silver-coated and antiseptic-impregnated ETTs; ETTs with thin-walled polyurethane cuffs; and HMEs, but these devices also can have adverse effects. Controversy still exists regarding the evidence, cost-effectiveness, and disadvantages and risks of these devices.

  17. Effect of heat shock on poly(ADP-ribose) synthetase and DNA repair in Drosophila cells

    Energy Technology Data Exchange (ETDEWEB)

    Nolan, N.L.; Kidwell, W.R.

    1982-04-01

    Poly(ADP-ribose) synthetase, a chromatin-bound enzyme which attaches polyanionic chains of ADP-ribose to nuclear proteins, was found to be temperature sensitive in intact Drosophila melanogaster cells. The synthetase was completely inactivated by heat-shocking the cells at 37/sup 0/C for 5 min, a condition which had no appreciable effect on the subsequent growth of Drosophila cells at their physiological temperature. The heat-shock effect on synthetase was reversible; enzyme activity began to reappear about 2 hr post heat shock. During the 2-hr interval when poly(ADP-ribose) synthetase was absent, the cells were competent in repair of ..gamma..-ray-induced DNA strand breaks as shown by DNA sedimentation studies on alkaline sucrose gradients. It is thus concluded that poly(ADP-ribose) synthesis is unnecessary for repair of DNA strand breaks introduced by irradiation. The same conclusion was reached from the fact that two inhibitors of poly(ADP-ribose) synthetase 3-aminobenzamide and 5-methylnicotinamide, failed to block repair of ..gamma..-ray-induced DNA chain breaks even though both inhibitors reduced the amount of poly(ADP-ribose) synthesized in cells by 50-75%. Although it was found that the repair of DNA strand breaks is independent of poly(ADP-ribose) synthesis, irradiation does activate the synthetase in control cells, as shown by radioimmunoassay of poly(ADP-ribose) levels.

  18. Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

    Science.gov (United States)

    Paul, Heather L.; Sompayrac, Robert; Conger, Bruce; Chamberlain, Mateo

    2009-01-01

    As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

  19. Evaluation of the Low Heat Input Process for Weld Repair of Nickel-Base Superalloys

    Science.gov (United States)

    Durocher, J.; Richards, N. L.

    2011-10-01

    The repair of turbine blades and vanes commonly involves gas tungsten arc welding or an equivalent process, but unfortunately these components are often susceptible to heat-affected zone (HAZ) cracking during the weld repair process. This is a major problem especially in cast alloys due to their coarse-grain size and where the (Al + Ti) contents is in excess of 3-4%; vacuum brazing is also used but mainly on low stress non-rotating components such as vanes. Micro-welding has the potential to deposit small amounts of filler at low heat input levels with minimum HAZ and thus is an attractive process for depositing a quality weld. As with conventional fusion processes, the filler alloy is deposited by the generation of a low power arc between a consumable electrode and the substrate. The low heat input of this process offers unique advantages over more common welding processes such as gas tungsten arc, plasma arc, laser, and electron beam welding. In this study, the low heat input characteristic of micro-welding has been used to simulate weld repair using Inconel (IN) (Inconel and IN are trademarks of INCO Alloys International) 625, Rene (Rene is a trademark of General Electric Company) 41, Nimonic (Nimonic is a trademark of INCO Alloys International) 105 and Inconel 738LC filler alloys, to a cast Inconel 738LC substrate. The effect of micro-welding process parameters on the deposition rate, coating quality, and substrate has been investigated.

  20. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  1. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  2. Simulation of the processes of heat- and the mass transfer in the rooms of public building with the natural ventilation

    Directory of Open Access Journals (Sweden)

    Prorokova Maria

    2017-01-01

    Full Text Available In the article the mathematical model of the processes of heat exchange and mass exchange in the room of building with the natural ventilation is shown. The verification of mathematical model is performed via the comparison of the results of calculation in ANSYS Fluent with the data of experiment. Experiment was conducted in the room of educational institution. In the experiment were measured the temperature of air, air speed and moisture content in air. A low relative error in the calculation with the use of a mathematical model makes its use for predicting the parameters of microclimate after the introduction of the energy-saving measures possible

  3. Research on Heat-Mechanical Coupling of Ventilated Disc Brakes under the Condition of Emergency Braking

    Science.gov (United States)

    Tan, Xuelong; Zhang, Jian; Tang, Wenxian; Zhang, Yang

    Taking the ventilated disc brake in some company as research object, and using UG to build 3D models of brake disc and pad, and making use of ABAQUS/Standard to set up two parts' finite element model, via the decelerated motion of actual simulation brake disc, which gets ventilated disc brake in the case of emergency breaking in time and space distribution of conditions of temperature and stress field, summarizes the distribution of temperature field and stress field, proves complex coupling between temperature, stress, and supplies the direct basis for brake's fatigue life analysis.

  4. Augmenting natural ventilation using solar heat and free cool energy for residential buildings

    Directory of Open Access Journals (Sweden)

    N. B. Geetha

    2014-03-01

    Full Text Available In many urban buildings ventilation is not sufficient that will increase the temperature and also create unhealthy atmosphere inside the room. In such buildings artificially induced ventilation through freely available energy promote comfort conditions by reducing the temperature by 2 to 3°C and also creating good circulation of fresh air inside the room. In the present work the concept of improving the ventilation by excess hot energy available during summer days from the solar flat plate collector and by storing cool energy available during the early morning hour in the Phase Change Material (PCM based storage system is attempted. An experimental setup is made to study the effect of improvement in natural ventilation and the results are reported. A visible reduction in temperature is observed through circulation of air from the bottom side of the room to the roof of the house using the stored hot and cool energy. A CFD analysis is also carried out using ANSYS-CFX software to simulate and evaluate the mass flow of air at the inlet and at the selected RTD location by matching the transient temperature profile of the simulated result with the experimental results at the selected RTD location.

  5. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M. [Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, University of Vigo, Campus Lagoas-Marcosende No. 9, 36310 Vigo (Spain)

    2011-01-15

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper. (author)

  6. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  7. The effect of a rotary heat exchanger in room-based ventilation on indoor humidity in existing apartments in temperate climates

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    The investigation constructed and simulated moisture balance equations for single-room ventilation with a non-hygroscopic rotary heat exchanger. Based on literature, the study assumed that all condensed moisture in the exhaust subsequently evaporated into the supply. Simulations evaluated...... the sensitivity to influential parameters, such as infiltration rate, heat recovery, and indoor temperature. With a typical moisture production schedule, the rotary heat exchanger recovered excessive moisture from kitchens and bathrooms,which provided a mold risk. The rotary heat exchanger was only suitable...... for single-room ventilation of dry rooms, such as living rooms and bedrooms. The sensitivity analysis concluded that varying heat recovery or indoor temperature could limit indoor relative humidity in dry rooms when a moderate risk was present. The rotary heat exchanger also elevated the minimum relative...

  8. VENTILATION MODEL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    V. Chipman

    2002-10-31

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their postclosure analyses.

  9. Mitochondrial-targeted DNA repair enzyme 8-oxoguanine DNA glycosylase 1 protects against ventilator-induced lung injury in intact mice.

    Science.gov (United States)

    Hashizume, Masahiro; Mouner, Marc; Chouteau, Joshua M; Gorodnya, Olena M; Ruchko, Mykhaylo V; Potter, Barry J; Wilson, Glenn L; Gillespie, Mark N; Parker, James C

    2013-02-15

    This study tested the hypothesis that oxidative mitochondrial-targeted DNA (mtDNA) damage triggered ventilator-induced lung injury (VILI). Control mice and mice infused with a fusion protein targeting the DNA repair enzyme, 8-oxoguanine-DNA glycosylase 1 (OGG1) to mitochondria were mechanically ventilated with a range of peak inflation pressures (PIP) for specified durations. In minimal VILI (1 h at 40 cmH(2)O PIP), lung total extravascular albumin space increased 2.8-fold even though neither lung wet/dry (W/D) weight ratios nor bronchoalveolar lavage (BAL) macrophage inflammatory protein (MIP)-2 or IL-6 failed to differ from nonventilated or low PIP controls. This increase in albumin space was attenuated by OGG1. Moderately severe VILI (2 h at 40 cmH(2)O PIP) produced a 25-fold increase in total extravascular albumin space, a 60% increase in W/D weight ratio and marked increases in BAL MIP-2 and IL-6, accompanied by oxidative mitochondrial DNA damage, as well as decreases in the total tissue glutathione (GSH) and GSH/GSSH ratio compared with nonventilated lungs. All of these injury indices were attenuated in OGG1-treated mice. At the highest level of VILI (2 h at 50 cmH(2)O PIP), OGG1 failed to protect against massive lung edema and BAL cytokines or against depletion of the tissue GSH pool. Interestingly, whereas untreated mice died before completing the 2-h protocol, OGG1-treated mice lived for the duration of observation. Thus mitochondrially targeted OGG1 prevented VILI over a range of ventilation times and pressures and enhanced survival in the most severely injured group. These findings support the concept that oxidative mtDNA damage caused by high PIP triggers induction of acute lung inflammation and injury.

  10. Heat flux to the helium cryogenic system elements in the case of incidental vacuum vessel ventilation with atmospheric air

    CERN Document Server

    CERN. Geneva

    2016-01-01

    The selection process for size in safety equipment for cold vessels or process pipes in cryogenic systems should take into consideration the incidental ventilation of the vacuum vessel with atmospheric air. In this case, a significant heat input toward the cold elements of the system can be expected. A number of experimental investigations have been done for the elements at liquid helium temperature which have been covered with 10 layers of MLI. The typical values of the heat flux were measured in a range of 3.7 to 5.0 kW/m2 of the element surface. The helium temperature parts are typically surrounded by thermal shields that are kept in a temperature range of 50-80K. On the external side, the thermal shields are covered with 30-40 layers of MLI while on the internal side, the shields are bare. The theoretical calculations of heat flux to the thermal shield, with respect to the possibility of air condensation and freezing on the bare side of the thermal shield, show that the heat flux to the thermal shield can...

  11. 谈建筑暖通空调的设计要点%On design for architectural heat-ventilation air-conditioners

    Institute of Scientific and Technical Information of China (English)

    王康成

    2015-01-01

    The paper indicates the concept for the heat-ventilation air-conditioner system,describes its basic key points of design from the design planning,loading calculation of air-conditioners,and ventilation system design,and puts forward the matters needing attention in the design,so as to ensure the design quality of the heat-ventilation air-conditioner system.%简述了暖通空调系统的含义,从设计规划、空调负荷计算、通风系统设计等方面,论述了建筑暖通空调的基本设计要点,提出了在设计中应该注意的问题,以保证暖通空调系统的设计质量。

  12. Phosgene Poisoning Caused by the Use of Chemical Paint Removers Containing Methylene Chloride in Ill-Ventilated Rooms Heated by Kerosene Stoves

    Science.gov (United States)

    Gerritsen, W. B.; Buschmann, C. H.

    1960-01-01

    Two cases resembling poisoning by phosgene following the use of a paint remover containing methylene chloride in ill-ventilated rooms heated by an oil stove are described. Experiments carried out under similar conditions demonstrated the production of phosgene in toxic concentrations. The potential hazards from non-inflammable solvents are discussed. PMID:13827592

  13. THE SCHOOL PLANT GUIDE FOR PLANNING SCHOOL PLANTS OF PENNSYLVANIA. ARCHITECTURAL DESIGN REQUIREMENTS AND GENERAL, ELECTRIC, HEATING AND VENTILATING, AND PLUMBING STANDARDS.

    Science.gov (United States)

    Pennsylvania State Dept. of Public Instruction, Harrisburg.

    A GUIDE COVERING ARCHITECTURAL DESIGN REQUIREMENTS, ELECTRIC, HEATING AND VENTILATING, AND PLUMBING STANDARDS AS APPROVED BY THE STATE BOARD OF EDUCATION IN 1966. THE FOLLOWING MINIMUM STANDARD FOR NEW BUILDING, ALTERATIONS, AND ADDITIONS ARE OUTLINED--(1) SPATIAL ENVIRONMENTAL FACTORS, SUCH AS CEILING HEIGHTS, INTERIOR SANITARY FACILITIES, ROOMS…

  14. Sustainable Heating, Cooling and Ventilation of a Plus-Energy House via Photovoltaic/Thermal Panels

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Sevela, Pavel

    2014-01-01

    Present work addresses the HVAC and energy concerns of the Technical University of Denmark's house, Fold, for the competition Solar Decathlon Europe 2012. Various innovative solutions are investigated; photovoltaic/thermal (PV/T) panels, utilization of ground as a heat source/sink and phase change...... two separate systems. PV/T panels enable the house to perform as a plus-energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively. The ground heat exchanger acts as the heat sink/source of the house. Free cooling enables the same cooling effect...

  15. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    OpenAIRE

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele; Toftum, Jørn

    2014-01-01

    Experience has shown that appropriate design of very low energy dwellings can be a large challenge and that the final design may result in insufficient heating in winter and overheating in summer. The 126 certified Passive House apartments (Ravnsborghusene) in Køge, Denmark are a low energy building project finished medio 2012. The design challenge was met with a concept of air heating that is individually controlled in every room. It also applies external solar shading. This study used indoo...

  16. The use of a double heat pipe heat exchanger system for reducing energy consumption of treating ventilation air in an operating theatre. A full year energy consumption model simulation

    Energy Technology Data Exchange (ETDEWEB)

    Yau, Y.H. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2008-07-01

    In two earlier papers [Y.H. Yau, Application of a heat pipe heat exchanger to dehumidification enhancement in tropical HVAC systems - a baseline performance characteristics study, International Journal of Thermal Sciences 46 (2) (2007) 164-171; ], two series of experiments were conducted under controlled conditions to establish the baseline performance characteristics of the heat pipe heat exchanger (HPHX). In the present paper, a complete empirical transient systems simulation program model is assembled to estimate the air states as well as the entire typical meteorological year energy consumption of an operating theatre located in Kuala Lumpur, Malaysia. The current heating, ventilating and air conditioning (HVAC) systems for the operating theatre are found to be inherently energy-inefficient and can be further improved with a double heat pipe heat exchanger system. The impact on actual energy consumption of a custom-built Trane Air Handler Unit 0704 2-2MB is simulated with two 8-row heat pipe heat exchanger installed in the heating, ventilating and air conditioning system compared to the existing without HPHX HVAC system. Based on this investigation, the application of a double heat pipe heat exchanger system (Plant E) in the conventional Air Handler Unit operating in a tropical climate is strongly recommended as an efficient mean for humidity control and energy savings to maintain acceptable room conditions per American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) requirements [ASHRAE, ASHRAE Handbook HVAC Applications SI Edition, ASHRAE, Atlanta, GA, USA, 1995]. (author)

  17. Heat transfers in a double-skin roof ventilated by natural convection in summer time

    CERN Document Server

    Biwole, Pascal; Pompeo, C

    2013-01-01

    The double-skin roofs investigated in this paper are formed by adding a metallic screen on an existing sheet metal roof. The system enhances passive cooling of dwellings and can help diminishing power costs for air conditioning in summer or in tropical and arid countries. In this work, radiation, convection and conduction heat transfers are investigated. Depending on its surface properties, the screen reflects a large amount of oncoming solar radiation. Natural convection in the channel underneath drives off the residual heat. The bi-dimensional numerical simulation of the heat transfers through the double skin reveals the most important parameters for the system's efficiency. They are, by order of importance, the sheet metal surface emissivity, the screen internal and external surface emissivity, the insulation thickness and the inclination angle for a channel width over 6 cm. The influence of those parameters on Rayleigh and Nusselt numbers is also investigated. Temperature and air velocity profiles on seve...

  18. The heating ventilation design of coal pit coal tunnel back of a heat plant%某热源厂受煤坑返煤地道供热通风设计

    Institute of Scientific and Technical Information of China (English)

    冯瑞峰

    2016-01-01

    结合某热源厂受煤坑返煤地道供热通风设计实例,阐述了一些地道供热通风设备的设计选型方法,并论述了返煤地道供热通风设计中的注意事项,解决了返煤地道供热通风设计中防火阀、防爆暖风机等设备设计选型中遇到的一些常见问题。%Combining with the design example of heating ventilation design of coal pit coal tunnel back of a heat plant,this paper elaborated the design and type selection method of some authentic heating and ventilation equipment,and discussed the matters needing attention in coal tunnel back heating and ventilation design,solved some common problems encountered in fire fighting valve,explosion-proof heater and other equipment type selection in coal tunnel back heating and ventilation design.

  19. Laboratory study of subjective perceptions to low temperature heating systems with exhaust ventilation in Nordic countries

    DEFF Research Database (Denmark)

    Jin, Quan; Simone, Angela; Olesen, Bjarne W.

    2017-01-01

    Given the global trends of rising energy demand and the increasing utilization of low-grade renewable energy, low-temperature heating systems can play key roles in improving building energy efficiency while providing a comfortable indoor environment. To meet the need to retrofit existing buildings...

  20. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    DEFF Research Database (Denmark)

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele

    2014-01-01

    building project finished medio 2012. The design challenge was met with a concept of air heating that is individually controlled in every room. It also applies external solar shading. This study used indoor climate measurements and dynamic simulations in one of these apartment buildings to evaluate thermal...

  1. Demand Controlled Economizer Cycles: A Direct Digital Control Scheme for Heating, Ventilating, and Air Conditioning Systems,

    Science.gov (United States)

    1984-05-01

    includes a heating coil and thermostatic control to maintain the air in this path at an elevated temperature, typically around 80 degrees Farenheit (80 F...1238 Aug 1 1236 1237 52 1074 1126 50 1033 1083 Sep 8 8 5W 862 7T 600 678 75 603 7r Oct 51 400 451 119 204 323 115 207 322 ov 64 123 287 187 71 258

  2. Ventilator Circuits, Humidification and Ventilator-Associated Pneumonia

    Directory of Open Access Journals (Sweden)

    Dean Hess

    1996-01-01

    Full Text Available Technical issues in the care of mechanically ventilated patients include those related to the ventilator circuit, humidification and ventilator-associated pneumonia. Principal issues related to ventilator circuits include leaks and compression volume. Circuit compression volume affects delivered tidal volume as well as measurements of auto-positive end-expiratory pressure and mixed expired PCO2. Resistance through the ventilator circuit contributes to patient-ventilator dyssynchrony during assisted modes of mechanical ventilation. Adequate humidification of inspired gas is necessary to prevent heat and moisture loss. Common methods of humidification of inspired gas during mechanical ventilation include use of active heated humidifiers and passive artificial noses. Artificial noses are less effective than active humidifiers and are best suited to short term use. With active humidifiers, the circuit can be heated to avoid condensate formation. However, care must be exercised when heated circuits are used to avoid delivery of a low relative humidity and subsequent drying of secretions in the artificial airway. Although pneumonia is a complication of mechanical ventilation, these pneumonias are usually the result of aspiration of pharyngeal secretions and are seldom related to the ventilator circuit. Ventilator circuits do not need to be changed more frequently than weekly for infection control purposes, and the incidence of ventilator-associated pneumonia may be greater with more frequent circuit changes.

  3. Effects of differential wall heating in street canyons on dispersion and ventilation characteristics of a passive scalar

    Science.gov (United States)

    Cai, Xiaoming

    2012-05-01

    This paper presents the first large-eddy simulation (LES) study of transfer and dispersion of a scalar released from a rough urban facet, either the street surface, the upstream-wall, or the downstream-wall, under the thermo-dynamical conditions of either the upstream-wall or the downstream-wall, plus the roof, heated by solar radiation. The boundary condition of a constant value is adopted for the scalars on the rough urban facets and a wall function is proposed for the scalars. The LES results demonstrate that dispersion inside the street canyon possesses distinctive characteristics for two conditions: the assisting condition in which the thermal-driven flow has the same direction as that of the wind-driven vortex and the opposing condition in which the thermal-driven flow has the opposite direction as that of the wind-driven vortex. For the street-released scalar under the opposing condition, the concentration fluctuations relative to the mean concentration can reach 50% and in general they are much larger than those for the assisting cases which are in the range of 25-30%. The exchange velocity of a scalar between the street canyon air and the urban boundary layer (UBL), wCB(c), is one order of magnitude larger than the exchange velocity between a facet and the urban boundary layer, UBL, w0B(c), indicating quantitatively that the resistance to the transfer of a facet-released scalar is dominated by the near-facet processes. As the temperature difference between the wall and the UBL, ΔT, increases, the total resistance to street canyon ventilation becomes more dominated by the near-facet resistance. The assisting conditions are favourable to ventilating the scalars from both walls, whereas the opposing conditions are only favourable to the ventilation of the downstream-wall released scalar. In the range of ΔT tested in this study, the exchange velocity, wCB(c), linearly increases with ΔT and can be well parameterised. For the assisting cases, the advective

  4. Semi-volatile organic compounds in heating, ventilation, and air-conditioning filter dust in retail stores.

    Science.gov (United States)

    Xu, Y; Liang, Y; Urquidi, J R; Siegel, J A

    2015-02-01

    Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi-volatile organic compounds (SVOCs). Filters in heating, ventilation, and air-conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co-occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di-n-butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas-phase is achieved. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Prototype of a computer method for designing and analyzing heating, ventilating and air conditioning proportional, electronic control systems

    Science.gov (United States)

    Barlow, Steven J.

    1986-09-01

    The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.

  6. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  7. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  8. Comparison of methods to evaluate the fungal biomass in heating, ventilation, and air-conditioning (HVAC) dust.

    Science.gov (United States)

    Biyeyeme Bi Mve, Marie-Jeanne; Cloutier, Yves; Lacombe, Nancy; Lavoie, Jacques; Debia, Maximilien; Marchand, Geneviève

    2016-12-01

    Heating, ventilation, and air-conditioning (HVAC) systems contain dust that can be contaminated with fungal spores (molds), which may have harmful effects on the respiratory health of the occupants of a building. HVAC cleaning is often based on visual inspection of the quantity of dust, without taking the mold content into account. The purpose of this study is to propose a method to estimate fungal contamination of dust in HVAC systems. Comparisons of different analytical methods were carried out on dust deposited in a controlled-atmosphere exposure chamber. Sixty samples were analyzed using four methods: culture, direct microscopic spore count (DMSC), β-N-acetylhexosaminidase (NAHA) dosing and qPCR. For each method, the limit of detection, replicability, and repeatability were assessed. The Pearson correlation coefficients between the methods were also evaluated. Depending on the analytical method, mean spore concentrations per 100 cm(2) of dust ranged from 10,000 to 682,000. Limits of detection varied from 120 to 217,000 spores/100 cm(2). Replicability and repeatability were between 1 and 15%. Pearson correlation coefficients varied from -0.217 to 0.83. The 18S qPCR showed the best sensitivity and precision, as well as the best correlation with the culture method. PCR targets only molds, and a total count of fungal DNA is obtained. Among the methods, mold DNA amplification by qPCR is the method suggested for estimating the fungal content found in dust of HVAC systems.

  9. 谈暖通空调节能问题%On energy-saving issues in heat-supply and ventilation air-conditioners

    Institute of Scientific and Technical Information of China (English)

    张志宇

    2016-01-01

    The paper introduces the meanings in the energy-saving design of heat-supply and ventilation air-conditioners,illustrates the design methods from the heat-supply,ventilation and air-conditioners,and sums up the precautions in the energy-saving design,so as to improve the u-tility ratio of the resources and enhance the extension of the energy-saving technique.%介绍了暖通空调节能设计的意义,从供暖、通风、空调三方面,阐述了暖通空调节能设计的方法,总结了节能设计中的注意事项,有利于提高能源的利用率,促进节能技术的推广应用。

  10. Research on Heat Recovery Technology for Reducing the Energy Consumption of Dedicated Ventilation Systems: An Application to the Operating Model of a Laboratory

    Directory of Open Access Journals (Sweden)

    Lian Zhang

    2016-01-01

    Full Text Available In this research, the application of heat pipes in the air handler dedicated to decoupling dehumidification from cooling to reduce energy consumption was simulated and investigated by simulations and experimental studies. The cooling load profiles and heat pipes with effectiveness of 0.45 and 0.6, respectively, were evaluated in achieving the desired space conditions and calculated hour by hour. The results demonstrated that for all examined cases, a heat pipe heat exchanger (HPHX can be used to save over 80% of the energy during the hours of operation of air conditioning. The overall energy reduction rate was from 3.2% to 4.5% under air conditioning system conditions. It was found that the energy saving potential of a laboratory was higher than for other kinds of buildings. Therefore, the dedicated ventilation system combined with heat recovery technology can be efficiently applied to buildings, especially for laboratories in subtropical areas.

  11. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  12. Analysis of energy management for heating, ventilating and air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Mohamed Elhelw

    2016-06-01

    Full Text Available In the office buildings, large energy is consumed due to poor thermal performance and low efficiencies of HVAC systems. A cooling load calculation is a basis for the design of building cooling systems. The current design methods are usually based on deterministic cooling loads, which are obtained by using design parameters. However, these parameters contain uncertainties, and they will be different from that used in the design calculation when the cooling system is put in use. The actual cooling load profile will deviate from that predicted in design. A modified bin method was used in this paper to optimize the energy efficiency ratio (EER. A design optimization method is proposed by considering uncertainties related to the cooling load calculation. Impacts caused by the uncertainties of seven factors are considered, including the outdoor weather conditions and internal heat sources. The cooling load distribution is analyzed. Comparison between the modified bin method and CLTD/SCL/CLF method is also conducted. With the distributions of their energy consumption, decision makers can select the optimal configuration based on quantified confidence. According to the economic benefits and energy efficiency ratio, using modified bin method will increase the overall energy efficiency ratio by 45.57%.

  13. Heating, ventilating, and air conditioning deactivation thermal analysis of PUREX Plant

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.W.; Gregonis, R.A. [Westinghouse Hanford Company, Richland, WA (United States)

    1997-08-01

    Thermal analysis was performed for the proposed Plutonium Uranium Extraction Plant exhaust system after deactivation. The purpose of the analysis was to determine if enough condensation will occur to plug or damage the filtration components. A heat transfer and fluid flow analysis was performed to evaluate the thermal characteristics of the underground duct system, the deep-bed glass fiber filter No. 2, and the high-efficiency particulate air filters in the fourth filter building. The analysis is based on extreme variations of air temperature, relative humidity, and dew point temperature using 15 years of Hanford Site weather data as a basis. The results will be used to evaluate the need for the electric heaters proposed for the canyon exhaust to prevent condensation. Results of the analysis indicate that a condition may exist in the underground ductwork where the duct temperature can lead or lag changes in the ambient air temperature. This condition may contribute to condensation on the inside surfaces of the underground exhaust duct. A worst case conservative analysis was performed assuming that all of the water is removed from the moist air over the inside surface of the concrete duct area in the fully developed turbulent boundary layer while the moist air in the free stream will not condense. The total moisture accumulated in 24 hours is negligible. Water puddling would not be expected. The results of the analyses agree with plant operating experiences. The filters were designed to resist high humidity and direct wetting, filter plugging caused by slight condensation in the upstream duct is not a concern. 19 refs., 2 figs.

  14. Preoperational test report, vent building ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  15. Preoperational test, vent building ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T., Westinghouse Hanford

    1996-08-20

    Preoperational Test Procedure for Vent Building Ventilation System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The Vent Building ventilation system provides ventilation, heating, cooling, and zone confinement control for the W-030 Project Vent Building. The tests verify correct System operation and correct indications displayed by the central Monitor and Control system.

  16. DEMAND CONTROLLED VENTILATION AND CLASSROOM VENTILATION

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Mendell, Mark J.; Davies, Molly; Eliseeva, Ekaterina; Faulkner, David; Hong, Tienzen; Sullivan, Douglas P.

    2014-01-06

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling. Major findings included: ? The single-location carbon dioxide sensors widely used for demand controlled ventilation frequently have large errors and will fail to effectively control ventilation rates (VRs).? Multi-location carbon dioxide measurement systems with more expensive sensors connected to multi-location sampling systems may measure carbon dioxide more accurately.? Currently-available optical people counting systems work well much of the time but have large counting errors in some situations. ? In meeting rooms, measurements of carbon dioxide at return-air grilles appear to be a better choice than wall-mounted sensors.? In California, demand controlled ventilation in general office spaces is projected to save significant energy and be cost effective only if typical VRs without demand controlled ventilation are very high relative to VRs in codes. Based on the research, several recommendations were developed for demand controlled ventilation specifications in the California Title 24 Building Energy Efficiency Standards.The research on classroom ventilation collected data over two years on California elementary school classrooms to investigate associations between VRs and student illness absence (IA). Major findings included: ? Median classroom VRs in all studied climate zones were below the California guideline, and 40percent lower in portable than permanent buildings.? Overall, one additional L/s per person of VR was associated with 1.6percent less IA. ? Increasing average VRs in California K-12 classrooms from the current average to the required level is estimated to decrease IA by 3.4percent, increasing State attendance-based funding to school districts by $33M, with $6.2 M in increased energy costs. Further VR increases would provide additional benefits

  17. Repair of radiation-induced heat-labile sites is independent of DNA-PKcs, XRCC1 or PARP

    Energy Technology Data Exchange (ETDEWEB)

    Stenerl& #246; w, Bo; Karlsson, Karin H.; Radulescu, Irina; Rydberg, Bjorn; Stenerlow, Bo

    2008-04-29

    Ionizing radiation induces a variety of different DNA lesions: in addition to the most critical DNA damage, the DSB, numerous base alterations, SSBs and other modifications of the DNA double-helix are formed. When several non-DSB lesions are clustered within a short distance along DNA, or close to a DSB, they may interfere with the repair of DSBs and affect the measurement of DSB induction and repair. We have previously shown that a substantial fraction of DSBs measured by pulsed-field gel electrophoresis (PFGE) are in fact due to heat-labile sites (HLS) within clustered lesions, thus reflecting an artifact of preparation of genomic DNA at elevated temperature. To further characterize the influence of HLS on DSB induction and repair, four human cell lines (GM5758, GM7166, M059K, U-1810) with apparently normal DSB rejoining were tested for bi-phasic rejoining after gamma irradiation. When heat-released DSBs were excluded from the measurements the fraction of fast rejoining decreased to less than 50% of the total. However, neither the half-times of the fast (t{sub 1/2} = 7-8 min) or slow (t{sub 1/2} = 2.5 h) DSB rejoining were changed significantly. At t=0 the heat-released DSBs accounted for almost 40% of the DSBs, corresponding to 10 extra DSB/cell/Gy in the initial DSB yield. These heat-released DSBs were repaired within 60-90 min in all tested cells, including M059K cells treated with wortmannin or DNA-PKcs defect M059J cells. Furthermore, cells lacking XRCC1 or Poly(ADP-ribose) polymerase-1 (PARP-1) rejoined both total DSBs and heat-released DSBs similar to normal cells. In summary, the presence of heat-labile sites have a substantial impact on DSB induction yields and DSB rejoining rates measured by pulsed-field gel electrophoresis, and HLS repair is independent of DNA-PKcs, XRCC1 and PARP.

  18. Validation of the criteria for initiating the cleaning of heating, ventilation, and air-conditioning (HVAC) ductwork under real conditions.

    Science.gov (United States)

    Lavoie, Jacques; Marchand, Geneviève; Cloutier, Yves; Lavoué, Jérôme

    2011-08-01

    Dust accumulation in the components of heating, ventilation, and air-conditioning (HVAC) systems is a potential source of contaminants. To date, very little information is available on recognized methods for assessing dust buildup in these systems. The few existing methods are either objective in nature, involving numerical values, or subjective in nature, based on experts' judgments. An earlier project aimed at assessing different methods of sampling dust in ducts was carried out in the laboratories of the Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST). This laboratory study showed that all the sampling methods were practicable, provided that a specific surface-dust cleaning initiation criterion was used for each method. However, these conclusions were reached on the basis of ideal conditions in a laboratory using a reference dust. The objective of this present study was to validate these laboratory results in the field. To this end, the laboratory sampling templates were replicated in real ducts and the three sampling methods (the IRSST method, the method of the U.S. organization National Air Duct Cleaner Association [NADCA] and that of the French organization Association pour la Prévention et l'Étude de la Contamination [ASPEC]) were used simultaneously in a statistically representative number of systems. The air return and supply ducts were also compared. Cleaning initiation criteria under real conditions were found to be 6.0 mg/100 cm(2) using the IRSST method, 2.0 mg/100 cm(2) using the NADCA method, and 23 mg/100 cm(2) using the ASPEC method. In the laboratory study, the criteria using the same methods were 6.0 for the IRSST method, 2.0 for the NADCA method, and 3.0 for the ASPEC method. The laboratory criteria for the IRSST and NADCA methods were therefore validated in the field. The ASPEC criterion was the only one to change. The ASPEC method therefore allows for the most accurate evaluation of dust accumulation in HVAC

  19. 某图书馆暖通空调系统设计分析%On heat-supply and ventilation air-conditioner system of some library

    Institute of Scientific and Technical Information of China (English)

    王秀山

    2016-01-01

    According to the design ideas for the library,from heat-supply and ventilation air-conditioner system,cold and heat source system,in-terior layout,professional cooperation and other aspects,the paper analyzes a series of problems in the heat-supply and ventilation air-conditioner of some library,and illustrates respective treatment measures,so as to create the comfortable reading environment with suitable temperature and humidity.%根据图书馆的设计理念,从暖通空调系统、冷热源系统、室内系统布置、专业配合等方面,分析了某图书馆暖通空调设计中存在的一系列问题,并阐述了相应的处理措施,旨在创造出温湿度适宜、环境清新的阅读环境.

  20. Building technical services - Compact equipment for heating, hot water preparation, ventilation and cooling - Appendix; Haustechnik - Kompaktgeraete (Heizen, Warmwasser, Lueften, Kuehlen - alles aus einem). Erkenntnisse aus der Praxis - Anhang

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Streit, S. [Haessig Sustech GmbH, Uster (Switzerland); Helfenfinger, D.; Keller, P. [Hochschule fuer Technik und Architektur Luzern (HSLU), Luzern (Switzerland)

    2009-06-15

    This comprehensive appendix to the final report for the Swiss Federal Office of Energy (SFOE) on compact equipment for heating, hot water preparation, ventilation and cooling presents detailed data on energy costs of the various apartments studied, as well as graphical representations of room temperatures and comfort, domestic hot water consumption, outdoor ambient temperatures and their influence on indoor temperatures for both summer and winter periods. System efficiency calculations and the methodologies used are described. Plans of the apartments that were examined complete this appendix.

  1. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  2. The 70 kDa heat shock protein assists during the repair of chilling injury in the insect, Pyrrhocoris apterus.

    Directory of Open Access Journals (Sweden)

    Vladimír Kostál

    Full Text Available BACKGROUND: The Pyrrhocoris apterus (Insecta: Heteroptera adults attain high levels of cold tolerance during their overwintering diapause. Non-diapause reproducing adults, however, lack the capacity to express a whole array of cold-tolerance adaptations and show relatively low survival when exposed to sub-zero temperatures. We assessed the competence of non-diapause males of P. apterus for responding to heat- and cold-stresses by up-regulation of 70 kDa heat shock proteins (Hsps and the role of Hsps during repair of heat- and cold-induced injury. PRINCIPAL FINDINGS: The fragments of P. apterus homologues of Hsp70 inducible (PaHsp70 and cognate forms (PaHsc70 were cloned and sequenced. The abundance of mRNA transcripts for the inducible form (qPCR and corresponding protein (Western blotting were significantly up-regulated in response to high and low temperature stimuli. In the cognate form, mRNA was slightly up-regulated in response to both stressors but very low or no up-regulation of protein was apparent after heat- or cold-stress, respectively. Injection of 695 bp-long Pahsp70 dsRNA (RNAi caused drastic suppression of the heat- and cold-stress-induced Pahsp70 mRNA response and the up-regulation of corresponding protein was practically eliminated. Our RNAi predictably prevented recovery from heat shock and, in addition, negatively influenced repair of chilling injuries caused by cold stress. Cold tolerance increased when the insects were first exposed to a mild heat shock, in order to trigger the up-regulation of PaHsp70, and subsequently exposed to cold stress. CONCLUSION: Our results suggest that accumulation of PaHsp70 belongs to a complex cold tolerance adaptation in the insect Pyrrhocoris apterus.

  3. Energy conservation does not cost anything. Tips for a correct handling of heating systems, ventilation, water, electricity; Energiesparen kostet nichts. Tipps fuer den richtigen Umgang mit Heizung, Lueftung, Wasser, Strom

    Energy Technology Data Exchange (ETDEWEB)

    Stockinger, Volker

    2012-07-01

    The author of the book under consideration provides valuable tips dealing with heating systems, ventilation, electricity and water. Easily understandable examples of straightforward measures with an immediate effect are explained. For example, proper ventilation and a proper utilization of water looks after the wallets and saves valuable resources. This guide was developed at the Competence Center ''Energy Efficient Buildings'' of the University of Applied Sciences in Munich (Federal Republic in Germany).

  4. The effect of catalase on recovery of heat-injured DNA-repair mutants of Escherichia coli.

    Science.gov (United States)

    Mackey, B M; Seymour, D A

    1987-06-01

    The apparent sensitivity of Escherichia coli K12 to mild heat was increased by recA (def), recB and polA, but not by uvrA, uvrB or recF mutations. However, addition of catalase to the rich plating medium used to assess viability restored counts of heat-injured recA, recB and polA strains to wild-type levels. E. coli p3478 polA was sensitized by heat to a concentration of hydrogen peroxide similar to that measured in autoclaved recovery medium. The apparent heat sensitivity of DNA-repair mutants is thus due to heat-induced sensitivity to the low levels of peroxide present in rich recovery media. It is proposed that DNA damage in heated cells could occur indirectly by an oxidative mechanism. The increased peroxide sensitivity of heat-injured cells was not due to a decrease in total catalase activity but may be related specifically to inactivation of the inducible catalase/peroxidase (HPI).

  5. DEVELOPMENT OF CONSTRUCTION OF A CATALYTIC REACTOR FOR METHANE OXIDISING IN VENTILATION AIR IN COAL MINES AND THE RESEARCH ON INTEGRATED “HEAT PIPE” RECUPERATOR

    Directory of Open Access Journals (Sweden)

    Lech Hys

    2013-04-01

    Full Text Available The article presents the analysis whose result is the selection of appropriate design and construction of a monolithic CMR reactor intended for oxidising methane from ventilation air in coal mines. The description of “heat-pipe” recuperator cooperating with the reactor was also presented. The research was mainly aimed at verifying the compliance with the work of autothermity premise obtained by the return of part of heat from catalytic reaction. The result of research was to define the range volumetric fume expense ensuring autothermity and the definition of maximum recuperator efficiency. The range of volumetric expense was 18–25 m3/h and maximum value of efficiency coefficient was η = 0.50 for the volumetric expense of 18 m3/h.

  6. Equivalence in Ventilation and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  7. Ventilation in low energy housing retrofits

    NARCIS (Netherlands)

    Mlecnik, E.

    2008-01-01

    According to the definition, passive houses in Europe meet a target energy demand for heating of less than 15 kWh per square meter and per year. This low level for the heating demand is based on heating by a small post-heater in the hygienic ventilation system at 52 °C maximum, while the ventilation

  8. Ventilation in low energy housing retrofits

    NARCIS (Netherlands)

    Mlecnik, E.

    2008-01-01

    According to the definition, passive houses in Europe meet a target energy demand for heating of less than 15 kWh per square meter and per year. This low level for the heating demand is based on heating by a small post-heater in the hygienic ventilation system at 52 °C maximum, while the ventilation

  9. 新型平板热管换热器热回收效率特性实验研究%Research on New Type of Plate Heat Pipe Heat Exchanger in Room Ventilation

    Institute of Scientific and Technical Information of China (English)

    于雯静; 刁彦华; 赵耀华; 张冀

    2011-01-01

    A plate heat pipe heat exchanger for room ventilation was designed. The advantages of the heat pipe heat exchanger are small and high compactness. In this paper, the effect of the working fluid (Rl13, R141b and their mixture) was investigated experimentally for the performance of the heat pipe heat exchanger. The overall experiments were carried out under the simulated summer condition, the vacuum of the heat pipe heat exchanger was set at 1 x 10-3 Pa, and the filling ratio (the ratio of the working fluid volume in the heat pipe heat exchanger to the volume of the heat pipe heat exchanger) was 1/3. The experimental results show that the heat pipe heat exchanger could gain a high efficiency of heat recovery. The effectiveness of heat pipe heat exchanger with R141b as working fluid is superior to other working fluid over the whole air volume range, and the maximum effectiveness could be reached 58.2%.%本文针对普通住宅房间设计了一台新型平板式热管换热器,该换热器结构紧凑、体积小巧。为研究该换热器的使用条件,本文开展了不同工质(R113、R141b以及这两种工质的混合物)对该热管换热器换热效率影响的实验研究。整个实验在夏季工况下进行,热管真空度为1×10^-3Pa,充液量(灌入热管换热器内的工质体积与热管换热器体积之比)为1/3。实验结果表明:该热管换热器热回收效率较高。在整个风量范围内,R141b作为工质的热管换热器换热效果最好,最高效率达到了58.2%。

  10. Ventilation effectiveness

    CERN Document Server

    Mathisen, Hans Martin; Nielsen, Peter V; Moser, Alfred

    2004-01-01

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy-to-understand descriptions of the indices used to mesure the performance of a ventilation system and which indices to use in different cases.

  11. Heating, Ventilating, and Air-Conditioning: Recent Advances in Diagnostics and Controls to Improve Air-Handling System Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig; Wray, Craig P.; Sherman, Max H.; Walker, I.S.; Dickerhoff, D.J.; Federspiel, C.C.

    2008-02-01

    The performance of air-handling systems in buildings needs to be improved. Many of the deficiencies result from myths and lore and a lack of understanding about the non-linear physical principles embedded in the associated technologies. By incorporating these principles, a few important efforts related to diagnostics and controls have already begun to solve some of the problems. This paper illustrates three novel solutions: one rapidly assesses duct leakage, the second configures ad hoc duct-static-pressure reset strategies, and the third identifies useful intermittent ventilation strategies. By highlighting these efforts, this paper seeks to stimulate new research and technology developments that could further improve air-handling systems.

  12. Ventilation and Heat Transfer Analysis of Three-Phase Asynchronous Wind Generators%三相异步风力发电机通风散热分析

    Institute of Scientific and Technical Information of China (English)

    曹飞; 郑国丽; 周黎民; 黄鹏程

    2014-01-01

    分析了三相异步风力发电机进行了通风散热。对电机整机的三维温度场进行了数值模拟和结果分析,并将计算结果与试验值进行比对。介绍了机座散热筋的设计原则和离心风扇的计算要点。根据电机的通风系统和冷却方式,分析了可能导致电机温升高的影响因素。结果表明:涉及的理论和分析方法对电机冷却性能的改进具有一定的参考价值。%Ventilation and heat transfer analysis of three-phase asynchronous wind generators was done from three aspects. First of all, numerical simulation and result analysis of three-dimensional temperature field of the generator was done and the results were compared with experimental values. Secondly, the design principle of cooling ribs and the key points of calculation for the centrifugal fan were introduced. Finally, the factors which can cause high temperature rise of generator were analyzed based on the ventilation system and cooling scheme of generator. The theory and analytic methods involved here have some reference value for cooling performance improvements of generator.

  13. Demand Controlled Ventilation and Classroom Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  14. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  15. Pretest Predictions for Ventilation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Y. Sun; H. Yang; H.N. Kalia

    2007-01-17

    The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, concrete pipe walls, and insulation that will be developed during the ventilation tests involving various test conditions. The results will be used as input to the following three areas: (1) Decisions regarding testing set-up and performance. (2) Assessing how best to scale the test phenomena measured. (3) Validating numerical approach for modeling continuous ventilation. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the ventilation tests, and develop and describe numerical methods that can be used to calculate the effects of continuous ventilation. Sensitivity studies to assess the impact of variation of linear power densities (linear heat loads) and ventilation air flow rates are included. The calculation is limited to thermal effect only.

  16. Heat exchangers for the ventilation of residential and working rooms. Waermeaustauscher fuer die Belueftung von Wohn- und Arbeitsraeumen

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, H. (Technische Univ. Muenchen, Garching (Germany). Fakultaet fuer Physik)

    1991-08-01

    Calculation, structure and dimensioning of a parallel plate heat exchanger are described, which operates in the counter-current method. A simple formula is indicated for the efficiency. The heat exchanger stands out for a high efficiency and a low pump capacity; it can be produced in self-construction. A theoretical efficiency of {eta}{sub the}=93% has been calculated and an experimental efficiency of {eta}{sub exp}=95% has been measured, where the efficiency is defined as the ratio of regained heat and heat contained exhaust air. With an air flow rate of 100 m{sup 3}/h an electric pump capacity of 18 W is necessary. (orig.).

  17. Evolution of microbial aerosol behaviour in heating, ventilating and air-conditioning systems--quantification of Staphylococcus epidermidis and Penicillium oxalicum viability.

    Science.gov (United States)

    Forthomme, A; Andrès, Y; Joubert, A; Simon, X; Duquenne, P; Bemer, D; Le Coq, L

    2013-01-01

    The aim of this study was to develop an experimental set-up and a methodology to uniformly contaminate several filter samples with high concentrations of cultivable bacteria and fungi. An experimental set-up allows contaminating simultaneously up to four filters for range of velocities representative of heating, ventilating and air-conditioning systems. The test aerosol was composed of a microbial consortium of one bacterium (Staphylococcus epidermidis) and one fungus (Penicillium oxalicum) and aerosol generation was performed in wet conditions. Firstly, the experimental set-up was validated in regards to homogeneity of the air flows. The bioaerosol was also characterized in terms of number and particle size distribution using two particle counters: optical particle counter Grimm 1.109 (optical diameters) and TSI APS 3321 (aerodynamic diameters). Moreover, stabilities of the number of particles generated were measured. Finally, concentrations of cultivable microorganisms were measured with BioSamplers (SKC) downstream of the four filters.

  18. DISAIN SISTEM KENDALI MESIN AIR LEAK TEST MENGGUNAKAN SISTEM KENDALI PLC OMRON CJ2M DI HVAC (HEATING, VENTILATING, AND AIR CONDITIONING LINE 6

    Directory of Open Access Journals (Sweden)

    Syahril Ardi

    2015-03-01

    Full Text Available Pada proses produksi pembuatan komponen HVAC (Heating, Ventilating, and Air Conditioning dari perusahaan manufaktur di Indonesia, memerlukan proses pengecekan kebocoran pada bagian HVAC. Proses pengecekan ini dilakukan untuk memastikan tidak ada komponen HVAC yang bocor sebelum dikirim ke pihak pelanggan. Penelitian ini dilakukan untuk membuat system dan alat air leak test. Mesin air leak test ini menggunakan prinsip kerja differential pressure air leak test, yaitu metode yang membandingkan antara tekanan udara yang diberikan ke produk dan master produk. Pada penelitian ini, kami membuat disain mesin air leak test menggunakan sistem kendali berupa air leak tester, PLC, dan HMI. Berdasarkan kondisi dengan kapasitas produksi yang meningkat karena bertambahnya permintaan dari customer, dapat ditanggulangi dengan adanya share loading produksi dari HVAC line 4 ke line baru, yaitu HVAC line 6. Hasil yang didapat dari pengujian deteksi kebocoran produk,didapat nilai parameter kebocoran produk sebesar 2.23 ml/min.

  19. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs.

  20. Lecture Notes on Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    The main task of the ventilation system or the air-conditioning system is to supply· and remove air and airborne materials and to supply or remove heat from a room. The necessary level of fresh air will be supplied to· a room by a ventilation system, and heat from equipment or solar radiation can...... be removed by an air-conditioning system. An industrial ventilation system may both take care of the occupants' comfort and the industrial processes in the area....

  1. Low-energy mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Claus Wessel; Hviid, Christian Anker

    2014-01-01

    and with as little energy consumption as 41.1 kWh/m2/year including heating and all building services with no use of renewable energy such as PVcells or solar heating. One of the key means of reaching the objectives was to implement mechanical ventilation with low pressure loss and therefore low energy consumption....... The project consists of two buildings, building one is 6 stories high, and building two is 4 stories high. The buildings have a gross area of 50,500 m2 including underground parking. The ventilation and indoor climate concept was to use mechanical ventilation together with mechanical cooling and fanassisted...

  2. Ventilation Effectiveness

    DEFF Research Database (Denmark)

    Mundt, M.; Mathisen, H. M.; Moser, M.;

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy...

  3. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  4. 2D Conduction Simulation of a PCM Storage Coupled with a Heat Pump in a Ventilation System

    Directory of Open Access Journals (Sweden)

    Joseph Virgone

    2016-06-01

    Full Text Available Efforts to simulate heat transfer in a PCM (Phase Change Material storage device are generally led by considerations of Biot number and material thickness, of 2D versus 1D representation, and of possible hysteresis effects arising from the characterisation of the PCM using differential scanning calorimetry (DSC. In this paper we present a numerical treatment of heat conduction in a paraffin-based storage brick, based on experimental data for a full scale, heat storage component studied under laboratory conditions. The PCM was modelled adopting equivalent thermophysical properties during the phase change. An equivalent heat capacity and thermal conductivity were provided for an appropriate description of energy release and storage in the process of solidification and melting. The geometry of the metal container induces 2D effects that are generally neglected in numerical modelling. The thickness of the plates (about 2 cm is sufficiently large to require the modelling of conduction in the PCM, but can also induce convection that has been neglected in this study. Experimental results are presented and compared for both a 1D and 2D model of the PCM device. It was concluded that a 2D representation is essential for configurations; like the case study and geometry we had; with a large difference in thermal conductivity between PCM and metal casing. Two curves of equivalent heat capacity (measured via DSC were introduced for heating and cooling phases. Comparisons to experimental results indicated significant errors in the models during melting and solidification of the PCM, which could be reduced by instead adopting the mean of the two heat capacity curves. The rate of temperature change during the experiments and for the DSC characterisation was analysed and found to explain well the observations. In particular, as novelty, two peaks of equivalent heat capacity have been observed with DSC when the rate is very low instead of only one peak using

  5. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    OpenAIRE

    Sanda Budea

    2014-01-01

    Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outle...

  6. Condensin HEAT subunits required for DNA repair, kinetochore/centromere function and ploidy maintenance in fission yeast.

    Directory of Open Access Journals (Sweden)

    Xingya Xu

    Full Text Available Condensin, a central player in eukaryotic chromosomal dynamics, contains five evolutionarily-conserved subunits. Two SMC (structural maintenance of chromosomes subunits contain ATPase, hinge, and coiled-coil domains. One non-SMC subunit is similar to bacterial kleisin, and two other non-SMC subunits contain HEAT (similar to armadillo repeats. Here we report isolation and characterization of 21 fission yeast (Schizosaccharomyces pombe mutants for three non-SMC subunits, created using error-prone mutagenesis that resulted in single-amino acid substitutions. Beside condensation, segregation, and DNA repair defects, similar to those observed in previously isolated SMC and cnd2 mutants, novel phenotypes were observed for mutants of HEAT-repeats containing Cnd1 and Cnd3 subunits. cnd3-L269P is hypersensitive to the microtubule poison, thiabendazole, revealing defects in kinetochore/centromere and spindle assembly checkpoints. Three cnd1 and three cnd3 mutants increased cell size and doubled DNA content, thereby eliminating the haploid state. Five of these mutations reside in helix B of HEAT repeats. Two non-SMC condensin subunits, Cnd1 and Cnd3, are thus implicated in ploidy maintenance.

  7. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state...

  8. Experimental Investigation of the Heat Transfer in a Room using Night-Time Coling by Mixing Ventilation

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Nørgaard, Jesper; Daniels, Ole

    2011-01-01

    different air change rates and three different temperature differences between the inlet air and the room temperature resulting in nine different cases where conducted. For all cases the convective and radiation energy exchange was calculated for all the room surfaces. The ceiling was subdivided into 22...... areas and the convective heat transfer coefficient ranged between 5 and 30 W/m2. The ratio of convective to total heat flow from the ceiling depends on the air change rate, ranging from approximately 40% at the low air change rates to approximately 70% at the high air change rate. Even though radiation...

  9. Energy performance of a ventilation system for a block of apartments with a ground source heat pump as generation system

    Science.gov (United States)

    Lucchi, M.; Lorenzini, M.; Valdiserri, P.

    2017-01-01

    This work presents a numerical simulation of the annual performance of two different systems: a traditional one composed by a gas boiler-chiller pair and one consisting of a ground source heat pump (GSHP) both coupled to two thermal storage tanks. The systems serve a bloc of flats located in northern Italy and are assessed over a typical weather year, covering both the heating and cooling seasons. The air handling unit (AHU) coupled with the GSHP exhibits excellent characteristics in terms of temperature control, and has high performance parameters (EER and COP), which make conduction costs about 30% lower than those estimated for the traditional plant.

  10. Ventilation Model and Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    V. Chipman

    2003-07-18

    This model and analysis report develops, validates, and implements a conceptual model for heat transfer in and around a ventilated emplacement drift. This conceptual model includes thermal radiation between the waste package and the drift wall, convection from the waste package and drift wall surfaces into the flowing air, and conduction in the surrounding host rock. These heat transfer processes are coupled and vary both temporally and spatially, so numerical and analytical methods are used to implement the mathematical equations which describe the conceptual model. These numerical and analytical methods predict the transient response of the system, at the drift scale, in terms of spatially varying temperatures and ventilation efficiencies. The ventilation efficiency describes the effectiveness of the ventilation process in removing radionuclide decay heat from the drift environment. An alternative conceptual model is also developed which evaluates the influence of water and water vapor mass transport on the ventilation efficiency. These effects are described using analytical methods which bound the contribution of latent heat to the system, quantify the effects of varying degrees of host rock saturation (and hence host rock thermal conductivity) on the ventilation efficiency, and evaluate the effects of vapor and enhanced vapor diffusion on the host rock thermal conductivity.

  11. 通风管管径对冷库地坪通风防冻系统传热性能影响的研究%Effect of ventilation tube diameter on heat transfer of cold storage floor antifreezing ventilation system

    Institute of Scientific and Technical Information of China (English)

    贾景福; 郝满晋; 赵建华

    2009-01-01

    为研究通风管管径对冷库地坪通风防冻系统传热性能的影响程度,建立三维稳态传热数学模型.对传热模型进行合理的简化,根据系统的传热过程确定传热模型的定解条件,利用PHOENICS软件对通风系统在不同通风管管径下的传热模型进行数值模拟分析.结果表明:通风管管径对冷库地坪通风防冻系统的传热性能有较大影响,指出通风管间距为1.5 m时的适当管径.%In order to investigate the effect of ventilation tube inside diameter on heat transfer of cold storage floor antifreezing ventilation system, a steady three-dimensional mathematical model of heat transfer was established. The heat-transfer model was reasonably simplified. The calculational conditions of the heat-transfer model were defined according to the heat-transfer process. The temperature fields of this system were simulated and calculated by PHOENICS under different tube inside diameter. The results showed that the effect of ventilation tube inside diameter was greater on thermal performance of cold storage floor antifreezing ventilation system. The proper tube inside diameter was pointed out for the cold storage floor with 1.5m tube spacing.

  12. Calcium contributes to photoprotection and repair of photosystem II in peanut leaves during heat and high irradiance

    Institute of Scientific and Technical Information of China (English)

    Sha Yang; Fang Wang; Feng Guo; Jing-Jing Meng; Xin-Guo Li; Shu-Bo Wan

    2015-01-01

    In this study, we investigated the effects of exogenous calcium nitrate on photoinhibition and thylakoid protein level in peanut plants under heat (40 °C) and high irradiance (HI) (1,200 mmol/m2 per s) stress. Compared with control seedlings (cultivated in 0 mmol/L Ca(NO3)2 medium), the maximal photochemical efficiency of photosystem II (PSII) in Ca2þ‐treated plants showed a slight decrease after 5 h stress, accompanied by lower degree of PSII closure (1‐qP), higher non‐photochemical quenching, and lower level of membrane damage. Ca2þ inhibitors were used to analyze the varieties of antioxidant enzymes activity and PSII proteins. These results indicated that Ca2þ could protect the subunits of PSII reaction centers from photoinhibition by reducing the generation of reactive oxygen species. In the presence of both ethyleneglycol‐bis(2‐aminoethylether)‐tetraacetic acid and ascorbic acid (AsA), the net degradation of the damaged D1 protein was faster than that only treated with AsA. Our previous study showed that either the transcriptional or the translational level of calmodulin was obviously higher in Ca2þ‐treated plants. These results suggested that, under heat and HI stress, the Ca2þ signal transduction pathway can al eviate the photoinhibition through regulating the protein repair process besides an enhanced capacity for scavenging reactive oxygen species.

  13. Experimental study of indoor thermal environment and ventilation effectiveness in a room with low temperature radiant floor heating system and ventilation systems%低温辐射地板供暖与供新风室内热环境及通风效率实验研究

    Institute of Scientific and Technical Information of China (English)

    吴小舟; 赵加宁; 王沣浩

    2015-01-01

    Experimentally studies indoor thermal environment parameter distribution and ventilation effectiveness in a room with low temperature radiant floor heating system combined with mixing ventilation system or displacement ventilation system.The results show that when radiant floor surface temperature ranges from 25 ℃ to 29 ℃,supply air temperature ranges from 15 ℃ to 19 ℃ and outdoor air change rate is 4.2 h-1 ,the distribution of indoor thermal environmental parameter is relatively uniform,the indoor vertical air temperature difference is less than 1 ℃ and ventilation effectiveness is approximately 1.0 when the low temperature radiant floor heating system is integrated with mixing ventilation system.The distribution of indoor thermal environmental parameter is relatively non-uniform,the indoor vertical air temperature difference is large and up to 4 ℃ and ventilation effectiveness is approximately 1.1 when low temperature radiant floor heating system is integrated with displacement ventilation system.%实验研究了低温辐射地板供暖系统分别与混合通风系统和置换通风系统复合时,办公房间室内热环境参数分布及新风系统的通风效率。结果表明:当辐射地板表面温度为25~29℃、送风温度为15~19℃及新风换气次数为4.2 h-1时,低温辐射地板供暖与混合通风复合室内热环境参数分布相对比较均匀,室内空气垂直温差较小,不超过1℃,新风系统的通风效率大约为1.0;与置换通风复合室内热环境参数分布相对比较不均匀,室内空气垂直温差较大,最大能达到4℃,新风系统的通风效率为1.1左右。

  14. Changes in Ocean Heat, Carbon Content, and Ventilation: A Review of the First Decade of GO-SHIP Global Repeat Hydrography.

    Science.gov (United States)

    Talley, L D; Feely, R A; Sloyan, B M; Wanninkhof, R; Baringer, M O; Bullister, J L; Carlson, C A; Doney, S C; Fine, R A; Firing, E; Gruber, N; Hansell, D A; Ishii, M; Johnson, G C; Katsumata, K; Key, R M; Kramp, M; Langdon, C; Macdonald, A M; Mathis, J T; McDonagh, E L; Mecking, S; Millero, F J; Mordy, C W; Nakano, T; Sabine, C L; Smethie, W M; Swift, J H; Tanhua, T; Thurnherr, A M; Warner, M J; Zhang, J-Z

    2016-01-01

    Global ship-based programs, with highly accurate, full water column physical and biogeochemical observations repeated decadally since the 1970s, provide a crucial resource for documenting ocean change. The ocean, a central component of Earth's climate system, is taking up most of Earth's excess anthropogenic heat, with about 19% of this excess in the abyssal ocean beneath 2,000 m, dominated by Southern Ocean warming. The ocean also has taken up about 27% of anthropogenic carbon, resulting in acidification of the upper ocean. Increased stratification has resulted in a decline in oxygen and increase in nutrients in the Northern Hemisphere thermocline and an expansion of tropical oxygen minimum zones. Southern Hemisphere thermocline oxygen increased in the 2000s owing to stronger wind forcing and ventilation. The most recent decade of global hydrography has mapped dissolved organic carbon, a large, bioactive reservoir, for the first time and quantified its contribution to export production (∼20%) and deep-ocean oxygen utilization. Ship-based measurements also show that vertical diffusivity increases from a minimum in the thermocline to a maximum within the bottom 1,500 m, shifting our physical paradigm of the ocean's overturning circulation.

  15. To Investigate the Influence of Building Envelope and Natural Ventilation on Thermal Heat Balance in Office Buildings in Warm and Humid Climate

    Science.gov (United States)

    Kini, Pradeep G.; Garg, Naresh Kumar; Kamath, Kiran

    2017-07-01

    India’s commercial building sector is witnessing robust growth. India continues to be a key growth market among global corporates and this is reflective in the steady growth in demand for prime office space. A recent trend that has been noted is the increase in demand for office spaces not just in major cities but also in smaller tier II and Tier III cities. Growth in the commercial building sector projects a rising trend of energy intensive mechanical systems in office buildings in India. The air conditioning market in India is growing at 25% annually. This is due to the ever increasing demand to maintain thermal comfort in tropical regions. Air conditioning is one of the most energy intensive technologies which are used in buildings. As a result India is witnessing significant spike in energy demand and further widening the demand supply gap. Challenge in India is to identify passive measures in building envelope design in office buildings to reduce the cooling loads and conserve energy. This paper investigates the overall heat gain through building envelope components and natural ventilation in warm and humid climate region through experimental and simulation methods towards improved thermal environmental performance.

  16. Changes in Ocean Heat, Carbon Content, and Ventilation: A Review of the First Decade of GO-SHIP Global Repeat Hydrography

    Science.gov (United States)

    Talley, L. D.; Feely, R. A.; Sloyan, B. M.; Wanninkhof, R.; Baringer, M. O.; Bullister, J. L.; Carlson, C. A.; Doney, S. C.; Fine, R. A.; Firing, E.; Gruber, N.; Hansell, D. A.; Ishii, M.; Johnson, G. C.; Katsumata, K.; Key, R. M.; Kramp, M.; Langdon, C.; Macdonald, A. M.; Mathis, J. T.; McDonagh, E. L.; Mecking, S.; Millero, F. J.; Mordy, C. W.; Nakano, T.; Sabine, C. L.; Smethie, W. M.; Swift, J. H.; Tanhua, T.; Thurnherr, A. M.; Warner, M. J.; Zhang, J.-Z.

    2016-01-01

    Global ship-based programs, with highly accurate, full water column physical and biogeochemical observations repeated decadally since the 1970s, provide a crucial resource for documenting ocean change. The ocean, a central component of Earth's climate system, is taking up most of Earth's excess anthropogenic heat, with about 19% of this excess in the abyssal ocean beneath 2,000 m, dominated by Southern Ocean warming. The ocean also has taken up about 27% of anthropogenic carbon, resulting in acidification of the upper ocean. Increased stratification has resulted in a decline in oxygen and increase in nutrients in the Northern Hemisphere thermocline and an expansion of tropical oxygen minimum zones. Southern Hemisphere thermocline oxygen increased in the 2000s owing to stronger wind forcing and ventilation. The most recent decade of global hydrography has mapped dissolved organic carbon, a large, bioactive reservoir, for the first time and quantified its contribution to export production (˜20%) and deep-ocean oxygen utilization. Ship-based measurements also show that vertical diffusivity increases from a minimum in the thermocline to a maximum within the bottom 1,500 m, shifting our physical paradigm of the ocean's overturning circulation.

  17. Identification of CdnL, a Putative Transcriptional Regulator Involved in Repair and Outgrowth of Heat-Damaged Bacillus cereus Spores.

    Directory of Open Access Journals (Sweden)

    Alicja K Warda

    Full Text Available Spores are widely present in the environment and are common contaminants in the food chain, creating a challenge for food industry. Nowadays, heat treatments conventionally applied in food processing may become milder to comply with consumer desire for products with higher sensory and nutritional values. Consequently subpopulations of spores may emerge that are sublethally damaged rather than inactivated. Such spores may germinate, repair damage, and eventually grow out leading to uncontrolled spoilage and safety issues. To gain insight into both the behaviour of damaged Bacillus cereus spores, and the process of damage repair, we assessed the germination and outgrowth performance using OD595 measurements and microscopy combined with genome-wide transcription analysis of untreated and heat-treated spores. The first two methods showed delayed germination and outgrowth of heat-damaged B. cereus ATCC14579 spores. A subset of genes uniquely expressed in heat-treated spores was identified with putative roles in the outgrowth of damaged spores, including cdnL (BC4714 encoding the putative transcriptional regulator CdnL. Next, a B. cereus ATCC14579 cdnL (BC4714 deletion mutant was constructed and assessment of outgrowth from heat-treated spores under food relevant conditions showed increased damage compared to wild type spores. The approach used in this study allows for identification of candidate genes involved in spore damage repair. Further identification of cellular parameters and characterisation of the molecular processes contributing to spore damage repair may provide leads for better control of spore outgrowth in foods.

  18. On application of intelligent access control system in energy-saving of heating ventilation air-conditioner system%谈智能门禁系统在暖通空调系统节能中的应用

    Institute of Scientific and Technical Information of China (English)

    苏伟; 焦春玲; 罗炜

    2012-01-01

    The paper introduces the basic components and functions of the intelligent access control system,illustrates the application of the intelligent access control system in the various energy-saving of heating ventilation air-conditioner systems,including the workhouse heating system,the ventilation system,and the air-conditioner system,so as to direct the practice and to enhance the development of the energy-saving technique of the heating ventilation air-conditioner.%针对智能门禁系统的基本组成及功能进行了具体介绍,分别阐述了智能门禁系统在厂房采暖系统、通风系统、空调系统等不同的暖通空调系统节能中的应用,以期指导实践,促进暖通空调领域节能技术的发展。

  19. Thermal analysis and testing for DIII-D ohmic heating coil repair

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.; Anderson, P.M.; Gootgeld, A.M.

    1997-11-01

    The DIII-D ohmic heating (OH) coil solenoid consists of two parallel windings of 48 turns each cooled by water. Each winding is made up of four parallel conductors. Desired thermal capacity of the coil is 20 MJ at a repetition rate of 10 min. One of the conductors started leaking water in July 1995. Since then, the coil has been operated at a reduced thermal load using one winding. An experiment followed by an analysis was undertaken to determine if the OH-coil could be operated at full capacity without cooling the leaking segment by relying on conduction heat transfer to the neighboring cooled conductors. The analysis took into consideration the transient energy equations, including the effect of conduction between neighboring conductors. The axial conduction was modeled in the conductor, but was ignored in the coolant. An experiment was performed on the undamaged coil winding to determine the thermal conductance between neighboring conductors. The experiment consisted of passing hot water through adjacent cooling channels of two conductors and cold water through the cooling channels of the remaining two conductors of the same winding. The flow rate, inlet and outlet temperatures from each circuit were measured during the transient. From the experimental data and analysis an average thermal conductance between the conductors was determined to be about 0.1 W/cm{sup 2}-C. Using the experimentally determined value of the thermal conductance, an analysis was performed on a coil winding consisting of one uncooled conductor and three cooled conductors. Results show that it is possible to operate the full OH-coil without cooling the damaged conductor to the desired thermal load of 20 MJ per pulse.

  20. Personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  1. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...

  2. Mixing Ventilation

    DEFF Research Database (Denmark)

    Kandzia, Claudia; Kosonen, Risto; Melikov, Arsen Krikor;

    In this guidebook most of the known and used in practice methods for achieving mixing air distribution are discussed. Mixing ventilation has been applied to many different spaces providing fresh air and thermal comfort to the occupants. Today, a design engineer can choose from large selection of ...

  3. ECOLO-HOUSE in the snowy town. Study of the ventilating function what the heat collecting system of the air duct utilizing attic has; Yukiguni ECOLO-HOUSE. Kison kaoku no yaneura wo riyoshita duct shunetsu system

    Energy Technology Data Exchange (ETDEWEB)

    Umemiya, H.; Hirosawa, K. [Yamagata University, Yamagata (Japan)

    1996-10-27

    Described in this paper is an air duct heat collecting system, forming a link in the chain of natural energy utilization, in an attic of a house actually in presence. When a sirocco fan (blowing air from an indoor induction duct into the room) at the base of the highblocked floor is turned, air is sucked through an air intake under the eaves into a heat collecting duct (constructed utilizing the tilt roof and rafter). Heat from the roof warmed by sunshine is absorbed by air in the heat collecting duct and is fed to the highblocked floor structure through a heat collecting room and the induction duct. This system functions quite effectively as a ventilating device. Dew condensation on the walls and floor and musty smell have been eliminated. This system is good enough as a heater even on chilly days in early spring when there is sunshine. In the time zone with the sun shining, the system collects 4{times}10{sup 4}kJ per day, exhibiting a heat collecting efficiency of 4%. The heat collecting duct was analyzed for thermal environment, and the heat flux of the collected heat was determined as Qk(W/m{sup 2}=0.1{times}I-1.3{Theta}d-{Theta}a). In this equation, I is the quantity of insolation (W/m{sup 2}), {Theta}d is the temperature in the heat collecting duct, and {Theta}a is the free air temperature. 2 refs., 8 figs.

  4. Differentiation of different mixed Listeria strains and also acid-injured, heat-injured, and repaired cells of Listeria monocytogenes using fourier transform infrared spectroscopy.

    Science.gov (United States)

    Nyarko, Esmond; Donnelly, Catherine

    2015-03-01

    Fourier transform infrared (FT-IR) spectroscopy was used to differentiate mixed strains of Listeria monocytogenes and mixed strains of L. monocytogenes and Listeria innocua. FT-IR spectroscopy was also applied to investigate the hypothesis that heat-injured and acid-injured cells would return to their original physiological integrity following repair. Thin smears of cells on infrared slides were prepared from cultures for mixed strains of L. monocytogenes, mixed strains of L. monocytogenes and L. innocua, and each individual strain. Heat-injured and acid-injured cells were prepared by exposing harvested cells of L. monocytogenes strain R2-764 to a temperature of 56 ± 0.2°C for 10 min or lactic acid at pH 3 for 60 min, respectively. Cellular repair involved incubating aliquots of acid-injured and heat-injured cells separately in Trypticase soy broth supplemented with 0.6% yeast extract for 22 to 24 h; bacterial thin smears on infrared slides were prepared for each treatment. Spectral collection was done using 250 scans at a resolution of 4 cm(-1) in the mid-infrared wavelength region. Application of multivariate discriminant analysis to the wavelength region from 1,800 to 900 cm(-1) separated the individual L. monocytogenes strains. Mixed strains of L. monocytogenes and L. monocytogenes cocultured with L. innocua were successfully differentiated from the individual strains when the discriminant analysis was applied. Different mixed strains of L. monocytogenes were also successfully separated when the discriminant analysis was applied. A data set for injury and repair analysis resulted in the separation of acid-injured, heat-injured, and intact cells; repaired cells clustered closer to intact cells when the discriminant analysis (1,800 to 600 cm(-1)) was applied. FT-IR spectroscopy can be used for the rapid source tracking of L. monocytogenes strains because it can differentiate between different mixed strains and individual strains of the pathogen.

  5. Repairing of Waste Heat Recovery Device in Ammonia Synthesis Unit%合成废热回收器的修复

    Institute of Scientific and Technical Information of China (English)

    张凤魁

    2013-01-01

    对废热回收器拆卸、检测、存在的问题及修复处理过程作一简要的总结,谨供同行参考。%Make a brief summary for disassembling and inspecting of the waste heat recovery device , testing , problems and repairing process , to provide reference for fellow colleagues .

  6. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-25

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  7. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-10-12

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  8. Comparative study on the ventilation mode of the residential building in Beijing area in winter

    Science.gov (United States)

    Wang, G. J.; Li, Q. P.; Guo, Y.; Hu, Y. H.

    2016-08-01

    With the development of residential energy conservation technology, the air tightness requirement of the window is higher and higher. So in winter the cold penetration wind cannot satisfy the requirement of indoor personnel to fresh air. The common ventilation mode includes natural ventilation, natural inlet and mechanical exhaust, wall type ventilator with heat exchange, ventilation unit with heat exchange. Looking for energy saving, comfortable way of ventilation, the application effect of the way of ventilation is evaluated in air distribution and comfort performance and the initial investment by FLUENT software. The conclusion is that the mode of ventilation unit with heat exchange has higher superiority compared with the others.

  9. Microstructural analysis as the indicator for suitability of weld repairing of the heat resistant Cr - Ni steel

    Directory of Open Access Journals (Sweden)

    Odanović, Z.

    2010-08-01

    Full Text Available Metallurgical evaluation was performed on a fractured column tube of the reformer furnace in an ammonia plant. The tubes were manufactured from centrifugally cast heat resistant steel HK 40. Optical and scanning electron microscope (SEM were used for microstructural and fracture analysis. For composition determination of the microconstituents energy dispersive X ray spectroscopy (EDS was used. To evaluate mechanical properties, hardness and microhardness measurements were performed. Investigations based on the microstructural features with the idea to indicate suitability of weld repair of the column were performed in this study. It was observed that the crack initiation, caused by oxidation/corrosion and thermal stresses induced by temperature gradient, appeared in the inner side of the tube wall and propagation occurred along grain boundaries. The results clearly showed the presence of an irregular microstructure which contributed to crack propagation through the tube wall. An occurrence of precipitated needle-shaped carbides/carbonitrides and brittle σ phase was also identified in the microstructure. Results of the microstructural and fracture analysis clearly indicate that reformer furnace columns made of heat resistant steel HK 40 were unsuitable for weld repair.

    La evaluación metalúrgica se realizó en un tubo de columna con fracturas, que es parte del horno reformador en una planta de amoníaco. Estos tubos son fundidos centrífugamente y fabricados en acero resistente al calor, de tipo HK- 40. Para el análisis microestructural de la fractura se ha utilizado microscopía óptica y electrónica de barrido (SEM. La composición de los micro-constituyentes se determinó por espectrometría de rayos X de energía dispersiva (EDS. Las propiedades mecánicas se evaluaron mediante mediciones de microdureza Vickers. Las investigaciones en este estudio se han llevado a cabo con el fin de demostrar la idoneidad de reparación por

  10. On analysis of application of green energy-saving technique of heat-supply and ventilation design%暖通设计中绿色节能技术的应用分析

    Institute of Scientific and Technical Information of China (English)

    张建峰

    2016-01-01

    According to the principle for the heat-supply and ventilation design,the paper analyzes the application of the green energy-saving de-sign from the solar energy,geothermal resources,and natural ventilation,and sums up the precautions of the energy-saving technique in the ap-plication,so as to enhance the utility of the resources.%根据暖通设计需遵循的原则,从太阳能、地热资源、自然通风等方面,分析了绿色节能技术在暖通设计中的应用,并总结了节能技术在运用中的注意事项,有利于提高能源的利用率。

  11. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated

  12. Proceedings of the 7th international mine ventilation congress

    Energy Technology Data Exchange (ETDEWEB)

    Wasilewski, S. (ed.)

    2001-07-01

    The proceedings contains 139 papers covering the topics: ventilation analysis; heat assessment; methane emission and drainage; human factors; health and contaminations; fans and systems; dust generation and control; ventilation network and simulation systems and virtual reality; mine explosions; ventilation studies; mine fire determination planning; mine fires prevention studies; diesels; and case studies. Selected papers have been abstracted for IEA Coal Research coal abstract database.

  13. Naturlig ventilation med varmegenvinding

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2006-01-01

    Naturlig ventilation i kontorbyggerier har været et alternativ til me-kanisk ventilation i små 10 år. Naturlig ventilation har den klare fordel, at der ikke forbruges elenergi ved ventilering af bygningen, fordi ventilatorer ikke er påkrævet. Imidlertid lider naturlig ventila-tion under de ulemper...

  14. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Peter N Cox

    1996-01-01

    Full Text Available There has been a recent explosion of interest in the use of liquid ventilation. Over time humans have lost the physiological attributes necessary for respiration in water. However, perfluorocarbons have high solubilities for oxygen and carbon dioxide, as well as a low surface tension. These characteristics allow them to be used as a medium to assist gas exchange and recruit atelectatic-dependent lung zones in respiratory distress syndrome. Current trials may prove perfluorocarbon to be a useful adjunct in lung protective strategies in respiratory distress syndrome.

  15. Low resource ventilation unit; Ressourcebesparende ventilationsenhed

    Energy Technology Data Exchange (ETDEWEB)

    Drivsholm, C.

    2012-03-15

    In the project a resource-saving ventilation device was developed which is based on the use of a regenerator and a reversible air flow. The regenerator is placed in the building envelope, and the concept works in the way that the heat in the air during ventilation is stored in the regenerator and brought back into the building by a reversible air change. The heated air is blown from inside the building out through the regenerator. In this way the regenerator accumulates the heat in the air. Over a period of 30-120 seconds, the regenerator capacity is utilized. When the regenerator cannot be further heated, the air flow is reversed and there is now blown cold air through the regenerator. Thereby the heat from the regenerator is released to the cold fresh air. Thus, the fresh air brings heat back into the building, whereby the air is replaced with a limited heat loss. Ventilation with a regenerator is described as micro-ventilation. The developed micro-ventilation unit was tested by the Danish Technological Institute. The test results shows that the unit performs according to expectations: 1) The heat recovery is 85%; 2) The flow through the unit is 80m3 per hour in a 5 section unit; 3) The noise level is 30 db(A) in a representative room; 4) The energy consumption is <300 J/m3. The unit is introduced into the market, and the first plants have been sold. (LN)

  16. Visible cost - invisible profit. The heating, ventilation and sanitary sector and the realization of energy conservation. Among politics, knowledge and practice; Synlig kostnad - skjult gevinst. VVS-bransjen og realisering av ENOEK. Mellom politikk, kunnskap og praksis

    Energy Technology Data Exchange (ETDEWEB)

    Hubak, Marit

    1998-07-01

    In social research, technology has customarily been considered problem-generating. What is needed to turn new technology into a positive instrument in environmental work? To answer this question one must understand the interaction between politics, knowledge and practice that is important for dealing with the environmental challenges. It is a main objective of this book to contribute to this understanding by analysing how the building industry deals with the energy and environmental challenges that are commonly known as energy conservation. Specifically, the book deals with the heating, ventilation and sanitary sector since this is where most of the companies working with energy conservation are found. The discussion applies to Norway0.

  17. Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores

    Directory of Open Access Journals (Sweden)

    A.S. Mendes

    2013-04-01

    Full Text Available This research had the objective of evaluating the influence of the natural ventilation on the surface temperature distribution of heated crates. The research used six crates from a farrowing room in a commercial swine production farm located in the state of São Paulo, Brazil. Three crates were heated using a heat mat while the other three had the environment heated by incandescent light bulbs (200W fixed on the lateral wall. The surface temperature of the crate's floor (1.55x0.55m was registered in 36 points, distributed in 18 quadrants (0.26x0.18m using an infrared thermometer in three different conditions of the room's natural ventilation: opened, semi-opened, and closed lateral curtain. The isotherms and the temperature distribution of the floor heat were processed using the SURFER® (1995, and the statistical analysis was done using the MINITAB® (Statistical..., 2002. It was found that the room's natural ventilation had a significant influence on crate floor surface temperature distribution. The crate with a heat mat system provided higher temperatures and led to a more homogeneous surface temperature distribution.O objetivo deste trabalho foi avaliar a influência da ventilação natural sobre a distribuição da temperatura na superfície de pisos aquecidos em escamoteadores. Foram avaliados seis escamoteadores da maternidade de uma granja de suínos localizada no estado de São Paulo. Dentre os escamoteadores avaliados, três deles usavam piso aquecido para o acondicionamento dos leitões, e os outros usavam lâmpadas incandescentes (200W, fixadas na parede lateral do interior do escamoteador. A temperatura da superfície do piso (1,55x0,55m foi registrada medindo-se 36 pontos distribuídos em 18 quadrantes (0,26x0,18m, por meio de um termômetro infravermelho, em três diferentes condições de ventilação natural: com cortina lateral aberta, semiaberta e totalmente fechada. As isotermas e a distribuição da temperatura sobre o piso

  18. YMP Engineered Barrier Systems Scaled Ventilation Testing

    Energy Technology Data Exchange (ETDEWEB)

    S.D. Dunn; B. Lowry; B. Walsh; J.D. Mar; C. Howard; R. Johnston; T. Williams

    2002-11-22

    Yucca Mountain, approximately 100 miles northwest of Las Vegas, Nevada, has been selected as the site for the nation's first geologic repository for high level nuclear waste. The Yucca Mountain Project (YMP) is currently developing the design for the underground facilities. Ventilation is a key component of the design as a way to maintain the desired thermal conditions in the emplacement drifts prior to closure. As a means of determining the effects of continuous ventilation on heat removal from the emplacement drifts two series of scaled ventilation tests have been performed. Both test series were performed in the DOE/North Las Vegas Atlas facility. The tests provided scaled (nominally 25% of the full scale emplacement drift design) thermal and flow process data that will be used to validate YMP heat and mass transport codes. The Phase I Ventilation Test series evaluated the ability of ambient ventilation air to remove energy under varying flow and input power conditions. The Phase II Ventilation Test series evaluated the ability of pre-conditioned ventilation air to remove energy under varying flow, input temperature and moisture content, and simulated waste package input power conditions. Twenty-two distinct ventilation tests were run.

  19. Reduction of electric power consumption in ventilation systems. Summary report 1999; Reduktion af elforbrug i ventilationsanlaeg. Sammenfatningsrapport 1999

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, N.B.

    1999-07-01

    The project aims at obtaining essential electricity savings in ventilation systems and heat recovery plants. Inside this area the project has dealt with: Research on the basic condition and parameters, which determine the electric power consumption in ventilation- and heat recovery plants, including better efficiency for ventilators and minimal pressure loss for heat recovery; Presentation of development of efficient ventilation systems with/without heat recovery with the purpose to initiate new product development in this area. The project includes reduction of electric power consumption in ventilation systems through improvement of ventilators and heat recovery systems. (EHS)

  20. Building technical services - Compact equipment for heating, hot water preparation, ventilation and cooling - Final report; Haustechnik - Kompaktgeraete (Heizen, Warmwasser, Lueften, Kuehlen - alles aus einem). Erkenntnisse aus der Praxis - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Streit, S. [Haessig Sustech GmbH, Uster (Switzerland); Helfenfinger, D.; Keller, P. [Hochschule fuer Technik und Architektur Luzern (HSLU), Luzern (Switzerland)

    2009-06-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents and discusses the knowledge gained in practice concerning compact equipment that can be used for heating, hot water preparation, ventilation and cooling. Such units combine heat-pumps and the further equipment necessary. Data on various factors were collected over a period of one year in three apartment blocks that meet Swiss Minergie-P very low energy consumption standards. Apart from the above mentioned factors, the study also considered humidity and carbon dioxide levels in the apartments and inhabitant behaviour. The authors note that the energy consumption of several apartments fell below the Minergie-P limiting, annual value of 30 kWh/m2. An increase in electricity consumption dependent on room temperatures is noted and commented on. The economic feasibility of Minergie-P and so-called passive housing is commented on.

  1. In vivo effects of UV radiation on multiple endpoints and expression profiles of DNA repair and heat shock protein (Hsp) genes in the cycloid copepod Paracyclopina nana.

    Science.gov (United States)

    Won, Eun-Ji; Han, Jeonghoon; Lee, Yeonjung; Kumar, K Suresh; Shin, Kyung-Hoon; Lee, Su-Jae; Park, Heum Gi; Lee, Jae-Seong

    2015-08-01

    To evaluate the effects of ultraviolet (UV) radiation on energy acquisition and consumption, the copepod Paracyclopina nana was irradiated with several doses (0-3kJ/m(2)) of UV. After UV radiation, we measured the re-brooding success, growth pattern of newly hatched nauplii, ingestion rate, and assimilation of diet. In addition, we checked the modulated patterns of DNA repair and heat shock protein (hsp) chaperoning genes of P. nana. UV-B radiation induced a significant reduction (7-87%) of the re-brooding rate of ovigerous females, indicating that UV-induced egg sac damage is closely correlated with a reduction in the hatching rate of UV-irradiated ovigerous female offspring. Using chlorophyll a and stable carbon isotope incubation experiments, we found a dose-dependent decrease (Pnana has an underlying ability to shift its balanced-energy status from growth and reproduction to DNA repair and adaptation. Also, expression of P. nana base excision repair (BER)-associated genes and hsp chaperoning genes was significantly increased in response to UV radiation in P. nana. These findings indicate that even 1kJ/m(2) of UV radiation induces a reduction in reproduction and growth patterns, alters the physiological balance and inhibits the ability to cope with UV-induced damage in P. nana.

  2. Contaminants in ventilated filling boxes

    Science.gov (United States)

    Bolster, D. T.; Linden, P. F.

    While energy efficiency is important, the adoption of energy-efficient ventilation systems still requires the provision of acceptable indoor air quality. Many low-energy systems, such as displacement or natural ventilation, rely on temperature stratification within the interior environment, always extracting the warmest air from the top of the room. Understanding buoyancy-driven convection in a confined ventilated space is key to understanding the flow that develops with many of these modern low-energy ventilation schemes. In this work we study the transport of an initially uniformly distributed passive contaminant in a displacement-ventilated space. Representing a heat source as an ideal sourced of buoyancy, analytical and numerical models are developed that allow us to compare the average efficiency of contaminant removal between traditional mixing and modern low-energy systems. A set of small-scale analogue laboratory experiments was also conducted to further validate our analytical and numerical solutions.We find that on average traditional and low-energy ventilation methods are similar with regard to pollutant flushing efficiency. This is because the concentration being extracted from the system at any given time is approximately the same for both systems. However, very different vertical concentration gradients exist. For the low-energy system, a peak in contaminant concentration occurs at the temperature interface that is established within the space. This interface is typically designed to sit at some intermediate height in the space. Since this peak does not coincide with the extraction point, displacement ventilation does not offer the same benefits for pollutant flushing as it does for buoyancy removal.

  3. 24 CFR 3280.103 - Light and ventilation.

    Science.gov (United States)

    2010-04-01

    ... installed ventilation capacity of the system be less than 50 cfm nor more than 90 cfm. The following.... (3) The ventilation system or a portion of the system is permitted to be integral with the home's heating or cooling system. The system must be capable of operating independently of the heating or cooling...

  4. Effect of solar radiation on natural ventilation performance in heated buildings%日照作用对热源建筑自然通风影响的研究

    Institute of Scientific and Technical Information of China (English)

    陈颖; 乐文璞; 莫松平; 郭文仙

    2015-01-01

    Referring to the main room of a transformer station ,a numerical model of a bilateral opening heat building was established . The sunlight intensity was vaired by changing the atmospheric transmittance (Sunshine Fraction) and the Fluent solver was utilized .The effects of solar radiation on the vent temperature ,the net heat flow between the indoor and outdoor space ,ventilation rate ,and velocity and temperature distribution were investigated .The results show that solar radiation has a significant impact on the magnitude and direction of the net heat flow between the indoor and outdoor environment .When the atmospheric transmittance is 0 .15 ,the net heat equilibrium comes to zero . Larger sunshine intensity results in increased ventilation rate and more uniform air velocity distribution .T he vertical air temperature distribution varies because of different main impact factors under sunshine conditions .%参照变电站主变压器室,建立了双侧开口热源建筑数值模型,通过改变大气透过率(sunshine fraction)的大小改变日照强度,利用FL U EN T进行求解,考察日照作用对热源建筑自然通风流动的影响。计算结果表明:日照作用影响热源建筑室内外热量传递的大小和方向,当大气透过率为0.15时,室内外两侧传递热量达到平衡。较大的日照强度导致通风量增大,室内气流速度分布更均匀,日照作用下不同高度的气流温度受到的主要影响因素不同。

  5. VENTILATION NEEDS DURING CONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    C.R. Gorrell

    1998-07-23

    The purpose of this analysis is to determine ventilation needs during construction and development of the subsurface repository and develop systems to satisfy those needs. For this analysis, construction is defined as pre-emplacement excavation and development is excavation that takes place simultaneously with emplacement. The three options presented in the ''Overall Development and Emplacement Ventilation Systems'' analysis (Reference 5.5) for development ventilation will be applied to construction ventilation in this analysis as well as adding new and updated ventilation factors to each option for both construction and development. The objective of this analysis is to develop a preferred ventilation system to support License Application Design. The scope of this analysis includes: (1) Description of ventilation conditions; (2) Ventilation factors (fire hazards, dust control, construction logistics, and monitoring and control systems); (3) Local ventilation alternatives; (4) Global ventilation options; and (5) Evaluation of options.

  6. Repairing ceramic insulating tiles

    Science.gov (United States)

    Dunn, B. R.; Laymance, E. L.

    1980-01-01

    Fused-silica tiles containing large voids or gauges are repaired without adhesives by plug insertion method. Tiles are useful in conduits for high-temperature gases, in furnaces, and in other applications involving heat insulation.

  7. In vivo effects of UV radiation on multiple endpoints and expression profiles of DNA repair and heat shock protein (Hsp) genes in the cycloid copepod Paracyclopina nana

    Energy Technology Data Exchange (ETDEWEB)

    Won, Eun-Ji; Han, Jeonghoon [Department of Biological Science, College of Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Lee, Yeonjung; Kumar, K. Suresh; Shin, Kyung-Hoon [Department of Marine Sciences and Convergent Technology, College of Science and Technology, Hanyang University, Ansan 426-791 (Korea, Republic of); Lee, Su-Jae [Department of Life Sciences, College of Natural Sciences, Hanyang University, Seoul 133-791 (Korea, Republic of); Park, Heum Gi, E-mail: hgpark@gwnu.ac.kr [Department of Marine Resource Development, College of Life Sciences, Gangneung-Wonju National University, Gangneung 210-702 (Korea, Republic of); Lee, Jae-Seong, E-mail: jslee2@skku.edu [Department of Biological Science, College of Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2015-08-15

    Highlights: • UV-B radiation induced a significant reduction of the re-brooding rate of ovigerous females. • A dose-dependent decrease in food ingestion and the rate of assimilation to the body upon UV radiation. • Expression of base excision repair-associated and hsp chaperoning genes was significantly increased upon UV radiation in P. nana. - Abstract: To evaluate the effects of ultraviolet (UV) radiation on energy acquisition and consumption, the copepod Paracyclopina nana was irradiated with several doses (0–3 kJ/m{sup 2}) of UV. After UV radiation, we measured the re-brooding success, growth pattern of newly hatched nauplii, ingestion rate, and assimilation of diet. In addition, we checked the modulated patterns of DNA repair and heat shock protein (hsp) chaperoning genes of P. nana. UV-B radiation induced a significant reduction (7–87%) of the re-brooding rate of ovigerous females, indicating that UV-induced egg sac damage is closely correlated with a reduction in the hatching rate of UV-irradiated ovigerous female offspring. Using chlorophyll a and stable carbon isotope incubation experiments, we found a dose-dependent decrease (P < 0.05) in food ingestion and the rate of assimilation to the body in response to UV radiation, implying that P. nana has an underlying ability to shift its balanced-energy status from growth and reproduction to DNA repair and adaptation. Also, expression of P. nana base excision repair (BER)-associated genes and hsp chaperoning genes was significantly increased in response to UV radiation in P. nana. These findings indicate that even 1 kJ/m{sup 2} of UV radiation induces a reduction in reproduction and growth patterns, alters the physiological balance and inhibits the ability to cope with UV-induced damage in P. nana.

  8. Probabilistic Analysis Methods for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Frier, Christian; Heiselberg, Per

    This paper discusses a general approach for the application of probabilistic analysis methods in the design of ventilation systems. The aims and scope of probabilistic versus deterministic methods are addressed with special emphasis on hybrid ventilation systems. A preliminary application of stoc...... of stochastic differential equations is presented comprising a general heat balance for an arbitrary number of loads and zones in a building to determine the thermal behaviour under random conditions....

  9. Humidification of inspired gases during mechanical ventilation.

    Science.gov (United States)

    Gross, J L; Park, G R

    2012-04-01

    Humidification of inspired gas is mandatory for all mechanically ventilated patients to prevent secretion retention, tracheal tube blockage and adverse changes occurring to the respiratory tract epithelium. However, the debate over "ideal" humidification continues. Several devices are available that include active and passive heat and moisture exchangers and hot water humidifiers Each have their advantages and disadvantages in mechanically ventilated patients. This review explores each device in turn and defines their role in clinical practice.

  10. Simplified modelling of displacement ventilation

    OpenAIRE

    Mateus, Nuno André Marques, 1987-

    2016-01-01

    Tese de doutoramento, Energia e Ambiente (Energia e Desenvolvimento Sustentável), Universidade de Lisboa, Faculdade de Ciências, 2016 With the aim of creating adequate indoor conditions, modern buildings use energy for space heating, ventilation and air conditioning (HVAC). The environmental impact of this energy use creates an urgent need to develop strategies to reduce HVAC related energy consumption. This thesis contributes to this goal by testing and developing simplified models for hi...

  11. Design of Local Ventilation by Full-Scale and Scale Modelling Techniques

    OpenAIRE

    Nielsen, Peter V.

    1997-01-01

    This paper will show the experiments with local ventilation of a filling machine from the paint industry, local ventilation of a film developing machine, experiments with a vortex exhaust opening and local heating of a checkout assistant's working place.

  12. Effectiveness of heating, ventilation and air conditioning system with HEPA filter unit on indoor air quality and asthmatic children's health

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ying; Raja, Suresh; Ferro, Andrea R.; Jaques, Peter A.; Hopke, Philip K. [Clarkson University, 8 Clarkson Avenue, Center for Air Resources Engineering and Science, Potsdam, NY 13699 (United States); Gressani, Cheryl; Wetzel, Larry E. [Air Innovations, Inc, 7000 Performance Drive, North Syracuse, NY 13212 (United States)

    2010-02-15

    Poor indoor air quality has been linked to the exacerbation of asthma symptoms in children. Because people spend most of their time indoors, improving indoor air quality may provide some relief to asthma sufferers. A study was conducted to assess whether operating an air cleaning/ventilating unit (HEPAiRx {sup registered}) in a child's bedroom can improve his/her respiratory health. Thirty children diagnosed with asthma were randomly split into two groups. For the first six weeks, group A had the air cleaning/ventilating unit (HEPAiRx {sup registered}) running in the bedrooms of the participants and group B did not; for the second six weeks, both groups had the cleaners running in the bedrooms; and, for the final six weeks, group A turned the cleaners off and group B kept theirs running. Indoor air quality parameters, including temperature, relative humidity, particulate matter (PM 0.5-10 {mu}m), carbon monoxide, carbon dioxide and total volatile organic compound (TVOC) concentrations, were monitored in each bedroom using an AirAdvice indoor air quality multi-meter. As a measure of pulmonary inflammation, exhaled breath condensate (EBC) was collected every sixth day and analyzed for nitrate and pH. Peak expiratory flow (PEF) was also measured. PM and TVOC concentrations decreased with operation of the HEPAiRx an average of 72% and 59%, respectively. The EBC nitrate concentrations decreased significantly and the EBC pH and PEF values increased significantly with operation of the unit (p < 0.001 when comparing on/off sample means). These results indicate that air cleaning in combination with ventilation can effectively reduce symptoms for asthma sufferers. (author)

  13. The Study of Heat Treatment Effects on Chromium Carbide Precipitation of 35Cr-45Ni-Nb Alloy for Repairing Furnace Tubes

    Directory of Open Access Journals (Sweden)

    Nakarin Srisuwan

    2016-01-01

    Full Text Available This paper presents a specific kind of failure in ethylene pyrolysis furnace tubes. It considers the case in which the tubes made of 35Cr-45Ni-Nb high temperature alloy failed to carburization, causing creep damage. The investigation found that used tubes became difficult to weld repair due to internal carburized layers of the tube. The microstructure and geochemical component of crystallized carbide at grain boundary of tube specimens were characterized by X-ray diffractometer (XRD, scanning electron microscopy (SEM with back-scattered electrons mode (BSE, and energy dispersive X-ray spectroscopy (EDS. Micro-hardness tests was performed to determine the hardness of the matrix and the compounds of new and used tube material. The testing result indicated that used tubes exhibited a higher hardness and higher degree of carburization compared to those of new tubes. The microstructure of used tubes also revealed coarse chromium carbide precipitation and a continuous carbide lattice at austenite grain boundaries. However, thermal heat treatment applied for developing tube weld repair could result in dissolving or breaking up chromium carbide with a decrease in hardness value. This procedure is recommended to improve the weldability of the 35Cr-45Ni-Nb used tubes alloy.

  14. Fundamentals of Refrigeration; Air Conditioning and Heating Mechanics 1--Appliance Repair 2: 9013.01 and 9025.05.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    Providing the student with an understanding of the basic refrigeration fundamentals, the course introduces the various types of tools and equipment used in this trade. The course consists of 90 clock hours and is organized into six instructional blocks. The student will gain an understanding of trade terminology, heat and temperature, transfer of…

  15. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion.

    Science.gov (United States)

    Kirton, O C; DeHaven, B; Morgan, J; Morejon, O; Civetta, J

    1997-10-01

    To compare the performance of an in-line heat moisture exchanging filter (HMEF) (Pall BB-100; Pall Corporation; East Hills, NY) to a conventional heated wire humidifier (H-wH) (Marquest Medical Products Inc., Englewood, Colo) in the mechanical ventilator circuit on the incidence of ventilator-associated pneumonia (VAP) and the rate of endotracheal tube occlusion. This report describes a prospective, randomized trial of 280 consecutive trauma patients in a 20-bed trauma ICU (TICU). All intubated patients not ventilated elsewhere in the medical center prior to their TICU admission were randomized to either an in-line HMEF or a H-wH in the breathing circuit. Ventilator circuits were changed routinely every 7 days, and closed system suction catheters were changed every 3 days. HMEFs were changed every 24 h, or more frequently if necessary. A specific endotracheal tube suction and lavage protocol was not employed. Patients were dropped from the HMEF group if the filter was changed more than three times a day or the patient was placed on a regimen of ultra high-frequency ventilation. The Centers for Disease Control and Prevention (CDC) criteria for diagnosis of pneumonia were used; early-onset, community-acquired pneumonia was defined if CDC criteria were met in 3 days. Laboratory and chest radiograph interpretation were blinded. The patient ages ranged from 15 to 95 years in the HMEF group and 16 to 87 years in the H-wH group (p=not significant), with a mean age of 46 years and 48 years, respectively. The male to female ratio ranged between 78 to 82%/22 to 18%, respectively, and 55% of all admissions were related to blunt trauma, 40% secondary to penetrating trauma, and 5% to major burns. There was no difference in Injury Severity Score (ISS) between the two groups. Moreover, there was no significant difference in mean ISS among those who did not develop pneumonia and those patients who developed either early-onset, community-acquired or late-onset, hospital

  16. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    with conventional ventilation systems (mixing or displacement ventilation), diffuse ceiling ventilation can significantly reduce or even eliminate draught risk in the occupied zone. Moreover, this ventilation system presents a promising opportunity for energy saving, because of the low pressure loss, extended free......Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as an air diffuser to supply fresh air into the room. Due to the large opening area, air is delivered to the room with very low velocity and no fixed direction, therefore the name ‘diffuse’. Compared......-cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...

  17. Validation of Boundary Conditions for CFD Simulations on Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus; Jensen, Rasmus Lund; Pedersen, D.N.

    2001-01-01

    The application of Computational Fluid Dynamics (CFD) for ventilation research and design of ventilation systems has increased during the recent years. This paper provides an investigation of direct description of boundary conditions for a complex inlet diffuser and a heated surface. A series of ...

  18. Optimization of repair cycles of VOMD-24 blowers

    Energy Technology Data Exchange (ETDEWEB)

    Kosarev, N.P.; Kuznetsov, S.V. (Sverdlovskii Gornyi Institut (USSR))

    1990-04-01

    Evaluates service life, reliability and repair of VOMD-24 blowers used for ventilation in underground coal mines in the USSR. Depending on operational conditions and ventilation systems, the overhaul life ranges from 7.2 to 14.7 months or 17.7 and 22.5 months (if general overhauls are considered). The mean-time-to repair ranges from 23.3 to 24.0 months, mean-time-to general overhaul from 32.6 to 38.0 months. The average labor consumption of blower repair and of general overhauls is analyzed along with labor consumption of service operations and repair. The recommended and actual standard repair cost, labor consumption and repair intervals are comparatively evaluated. Mathematical models for optimization of repair intervals are evaluated. Use of mathematical modeling for reducing repair cost, increasing blower reliability and reducing losses caused by blower failures is analyzed. 4 refs.

  19. Ventilation Systems Operating Experience Review for Fusion Applications

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader

    1999-12-01

    This report is a collection and review of system operation and failure experiences for air ventilation systems in nuclear facilities. These experiences are applicable for magnetic and inertial fusion facilities since air ventilation systems are support systems that can be considered generic to nuclear facilities. The report contains descriptions of ventilation system components, operating experiences with these systems, component failure rates, and component repair times. Since ventilation systems have a role in mitigating accident releases in nuclear facilities, these data are useful in safety analysis and risk assessment of public safety. An effort has also been given to identifying any safety issues with personnel operating or maintaining ventilation systems. Finally, the recommended failure data were compared to an independent data set to determine the accuracy of individual values. This comparison is useful for the International Energy Agency task on fusion component failure rate data collection.

  20. Complications of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Drašković Biljana

    2011-01-01

    Full Text Available Mechanical ventilation of the lungs, as an important therapeutic measure, cannot be avoided in critically ill patients. However, when machines take over some of vital functions there is always a risk of complications and accidents. Complications associated with mechanical ventilation can be divided into: 1 airway-associated complications; 2 complications in the response of patients to mechanical ventilation; and 3 complications related to the patient’s response to the device for mechanical ventilation. Complications of artificial airway may be related to intubation and extubation or the endotracheal tube. Complications of mechanical ventilation, which arise because of the patient’s response to mechanical ventilation, may primarily cause significant side effects to the lungs. During the last two decades it was concluded that mechanical ventilation can worsen or cause acute lung injury. Mechanical ventilation may increase the alveolar/capillary permeability by overdistension of the lungs (volutrauma, it can exacerbate lung damage due to the recruitment/derecruitment of collapsed alveoli (atelectrauma and may cause subtle damages due to the activation of inflammatory processes (biotrauma. Complications caused by mechanical ventilation, beside those involving the lungs, can also have significant effects on other organs and organic systems, and can be a significant factor contributing to the increase of morbidity and mortality in critically ill of mechanically ventilated patients. Complications are fortunately rare and do not occur in every patient, but due to their seriousness and severity they require extensive knowledge, experience and responsibility by health-care workers.

  1. 加温湿化氧疗在重型颅脑损伤患者中的应用研究%The application of heated humidification oxygen therapy during weaning from ventilation in patients with severe traumatic brain injury

    Institute of Scientific and Technical Information of China (English)

    徐蕴芳; 魏迎兵; 周丽梅

    2012-01-01

    目的 探讨重型颅脑损伤患者脱机后使用持续加温湿化氧疗的效果.方法 将80例重型颅脑损伤随机分为观察组和对照组,各40例,观察组采用新型氧疗机进行加温湿化给氧,对照组采用传统人工鼻湿化给氧.结果 观察组患者呼吸频率、痰液黏稠度、二氧化碳分压及肺部感染率均显著低于对照组(P<0.01).结论 持续加温湿化氧疗对重型颅脑损伤患者的湿化效果满意,能有效降低肺部感染率.%Objective To evaluate the effectiveness of continues heated humidification oxygen therapy during weaning from ventilation in after ventilator withdrawal. Methods 50 cases of severe traumatic brain injury patients were divided into experimental and control groups,each 25 cases. The experimental group was given airway humidification and oxygen therapy with production of oxygen therapy machine ( Fisher & Paykel Healthcare Corporation,New Zealand). Control group used traditional artificial nasal airway humidification of oxygen. Results The airway environmental indicators like respiratory rate, sputum viscosity, partial pressure of carbon dioxide were significantly lower than which in the control group,with a significant differences (P<0.01 ). The occurrence of pulmonary infection in the experimental group was lower than which in the control group ( P < 0. 01). Conclusion The oxygen therapy machine is better than traditional artificial nose of humidification and maintain toward airway environment in severe traumatic brain injury patients, and can reduce pulmonary infection rate in a certain degree.

  2. Natural ventilation for controlling the indoor microclimate

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, M.; Dell' Osso, G.R.; Iannone, F. [Politecnico di Bari (Italy). Dipt. di Architettura e Urbanistica

    2004-07-01

    The results of CFD numerical simulations show that the stairwell can have a fundamental role in the natural ventilation of low-rise multifamily buildings (three to five levels) in winter. The natural ventilation system here presented is characterized by low installation costs, quite easy operation and inexpensive management. In this case-study, the main design rules to obtain an effective natural ventilation system are: location and size of inlet and outlet (to move upward the neutral pressure level above the upper extraction grille device) and the aerodynamic characteristics of the openings (to equalize the flow rates). CFD simulations showed effective behaviour of the above mentioned ventilation system. The well known stack effect simplified model cannot be used in the case studied because the stairwell was characterized by complex geometry and boundary conditions. So, CFD codes are an invaluable tool in the design and verification of the behaviour of the stairwell performing as a chimney. The behaviour of the system studied is influenced by a great number of parameters depending on the external micro-climate (such as air temperature and solar radiation), the stairwell (such as the morphology and the geometry of the stairwell, the location and the aerodynamic characteristics of the openings, the thermal properties of the envelope), the dwellings (heating temperature, pressure losses along the internal flow path), the users (the control of the natural ventilation system and the heating scheduling/operation). The results shown only concern a certain number of the typical boundary conditions. However, these results can be useful for the design of other similar natural ventilation systems. Future research projects will concern the evaluation of different boundary conditions. The further aim is the definition of the most relevant parameters for the designing of similar systems. Further CFD simulations will be run to test different boundary conditions and different

  3. Energy and IAQ Implications of Residential Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    This study evaluates the energy, humidity and indoor air quality (IAQ) implications of residential ventilation cooling in all U.S. IECC climate zones. A computer modeling approach was adopted, using an advanced residential building simulation tool with airflow, energy and humidity models. An economizer (large supply fan) was simulated to provide ventilation cooling while outdoor air temperatures were lower than indoor air temperatures (typically at night). The simulations were performed for a full year using one-minute time steps to allow for scheduling of ventilation systems and to account for interactions between ventilation and heating/cooling systems.

  4. IMPACT OF HEATING AND AIR CONDITIONING SYSTEM OPERATION AND LEAKAGE ON VENTILATION AND INTERCOMPARTMENT TRANSPORT: STUDIES IN UNOCCUPIED AND OCCUPIED TENNESSEE VALLEY HOMES

    Science.gov (United States)

    Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay In 39 occupied houses. An average Increase in air infiltration rate of 0...

  5. New generation ventilators.

    Science.gov (United States)

    Bersten, A D; Skowronski, G A; Oh, T E

    1986-08-01

    Desirable features of new generation intensive care ventilators include the ability to ventilate a wide range of patient sizes, an uncomplicated control panel, an appropriate but not excessive variety of ventilatory patterns, adequate patient monitoring and alarm functions, and simplicity of cleaning and routine maintenance. Examples of currently available ventilators include the Servo 900-C, CPU-1, Engstrom Erica, Bear 5, Drager EV-A and Hamilton Veolar. The incorporation of microcomputer control into some of these ventilators has resulted in improved flexibility and a limited number of automatic responses to detected patient changes. However, the function of components provided to allow spontaneous ventilation, such as demand valves, requires considerable improvement. Current trends in ventilator design include further refinement of computer control and the provision of graphic displays showing the results of continuous sophisticated analysis of respiratory function. The extent to which these developments will prove clinically useful will require careful evaluation.

  6. ASHRAE Standard 62: tobacco industry's influence over national ventilation standards

    OpenAIRE

    Bialous, S.; Glantz, S

    2002-01-01

    Objective: To describe the role of the tobacco industry in the development of ventilation standards for indoor air quality by influencing the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE).

  7. Design Principles for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system -Hybrid Ventilation....... The hybrid ventilation concepts, design challenges and - principles are discussed and illustrated by four building examples....

  8. Enhanced natural ventilation method for atrium space

    NARCIS (Netherlands)

    An, H.

    2011-01-01

    This paper is written for the TIDO-course AR0532 Smart & Bioclimatic Design Theory. Energy saving is a relevant issue nowadays. Heating, ventilation and air conditioning (HVAC) occupies the largest portion both in residential and non-residential field. This consumption goes with the demand for ther

  9. Effect of continuous positive airway pressure during one lung ventilation on pulmonary function in patients undergoing video-assisted thoracoscopic repair of atrial septal defect%单肺通气期间连续气道正压通气对胸腔镜房间隔缺损修补术患者肺功能的影响

    Institute of Scientific and Technical Information of China (English)

    王磊; 陈宇; 钱燕宁; 丁正年; 孙杰

    2010-01-01

    目的 探讨单肺通气期间连续气道正压通气(CPAP)对胸腔镜房间隔缺损修补术患者肺功能的影响.方法 拟行房间隔缺损修补术的患者20例,年龄16~30岁,体重41~64 kg,性别不限,ASA分级Ⅱ级,随机分为2组(n=10):对照组和CPAP组.两组单肺通气时VT 8 ml/kg,呼吸频率12~16次/min,吸呼比1:2,维持PET CO2 35~40 mm Hg.CPAP组单肺通气期间,非通气侧肺采用CPAP,压力为6 cm H2O.术中监测氧合指数、肺顺应性和气道压,记录拔管时间、单肺通气期间心血管事件和低氧血症的发生情况.结果 与对照组比较,CPAP组氧合指数和肺顺应性升高,拔管时间缩短,低氧血症发生率低(P<0.01),两组患者气道压力在正常范围且未发生心血管事件.结论 单肺通气期间行CPAP(6 cm H2O)可改善胸腔镜房间隔缺损修补术患者的肺功能.%Objective To investigate the effect of continuous positive airway pressure(CPAP)during one lung ventilation on pulmonary function in patients undergoing video-assisted thoracoscopic repair of atrial septal defect.Methods Twenty ASA Ⅱ patients of both sexes,aged 16-30 yr,weighing 41-64 kg,scheduled for video-assisted thoracoscopic repair of atrial septal defect,were randomly divided into 2 groups(n = 10 each): control group and CPAP group.One lung ventilation(VT 8 ml/kg,RR 12-16 bpm,I:E 1:2,PETCO2 35-40 mm Hg)was perform in both groups.CPAP(6 cm H2O)was perform during one lung ventilation in group CPAP.The oxygenation index,pulmonary compliance and airway pressure were recorded during operation.The cardiovascular events,hyoxemia and extubation time were recorded.Results The oxygenation index and pulmonary compliance were significantly higher,extubation time was shorter,and the incidence of hyoxemia was lower in CPAP group than in control group(P < 0.01).The airway pressure was in the normal range in both groups.No cardiovascular events was found in both groups.Conclusion CPAP(6cm H2O)during one lung

  10. Mechanical ventilation in children.

    Science.gov (United States)

    Kendirli, Tanil; Kavaz, Asli; Yalaki, Zahide; Oztürk Hişmi, Burcu; Derelli, Emel; Ince, Erdal

    2006-01-01

    Mechanical ventilation can be lifesaving, but > 50% of complications in conditions that require intensive care are related to ventilatory support, particularly if it is prolonged. We retrospectively evaluated the medical records of patients who had mechanical ventilation in the Pediatric Intensive Care Unit (PICU) during a follow-up period between January 2002-May 2005. Medical records of 407 patients were reviewed. Ninety-one patients (22.3%) were treated with mechanical ventilation. Ages of all patients were between 1-180 (median: 8) months. The mechanical ventilation time was 18.8 +/- 14.1 days. Indication of mechanical ventilation could be divided into four groups as respiratory failure (64.8%), cardiovascular failure (19.7%), central nervous system disease (9.8%) and safety airway (5.4%). Tracheostomy was performed in four patients. The complication ratio of mechanically ventilated children was 42.8%, and diversity of complications was as follows: 26.3% atelectasia, 17.5% ventilator-associated pneumonia, 13.1% pneumothorax, 5.4% bleeding, 4.3% tracheal edema, and 2.1% chronic lung disease. The mortality rate of mechanically ventilated patients was 58.3%, but the overall mortality rate in the PICU was 12.2%. In conclusion, there are few published epidemiological data on the follow-up results and mortality in infants and children who are mechanically ventilated.

  11. Natural Ventilation in Atria

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Hendriksen, Ole Juhl

    This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions.......This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions....

  12. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  13. Energetic valuation of a combination system for heating/cooling and ventilation. Final report; Energetische Bewertung eines kombinierten Systems zur Heizung/Kuehlung und Lueftung. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Doege, K.; Franzke, U.; Frenzel, W.P.; Krause, R.; Seifert, C.

    1998-12-15

    The aim of the research project was to gather comprehensive, detailed information on floors penetrated by air flow under the aspect of heating and cooling. Building on an analysis of the factors liable to influence floors, different ways of information acquisition were realized. They comprised both fluidic experimental setups, which are used simultaneously to measure dust deposition, and fluidic-and-thermal experimental setups, permitting to investigate the performance and dynamics of floors more effectively. Within the framework of the experiments relating to flow processes, flow distribution (speed distribution) is investigated in the first part as a basis for the subsequent analysis of heat transport. In the second part, the pressure losses of the main elements intake module, hollow floor and outlet module are measured individually and for the overall system. Particular heed is paid to back-coupling occurring between the individual elements. Following the fluidic measurements, an investigation of thermal behaviour for the event of heating and cooling is planned. This includes establishing average operating parameters for summer and winter, which can be used to assess actual heat flows. The most important of these characteristic quantities are the heat transmission coefficients on the air side and room side. In parallel, measuring probes were built in an executed systems - an office building at Jueterbog and the Berufsfoerderwerk Glauchau - with a view to obtaining reference values from practical operation or back-couplings for laboratory operation. (orig.) [Deutsch] Die Zielsetzung des Forschungsvorhabens war, umfangreiche Detailinformationen ueber den luftdurchstroemten Fussboden unter dem Aspekt des Heizens und Kuehlens zu erlangen. Aufbauend auf einer Analyse der moeglichen Einflussfaktoren des Fussbodens wurde verschiedene Arten der Informationsgewinnung realisiert. Dazu gehoerten sowohl stroemungstechnische Versuchsaufbauten, die zugleich fuer die

  14. Recommended Ventilation Strategies for Energy-Efficient Production Homes

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, J.; Brown, R.; Koomey, J.; Warner, J.; Greenberg, S.

    1998-12-01

    This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR{reg_sign} Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis Department at Lawrence Berkeley National Lab compared residential ventilation strategies in four climates according to three criteria: total annualized costs (the sum of annualized capital cost and annual operating cost), predominant indoor pressure induced by the ventilation system, and distribution of ventilation air within the home. The mechanical ventilation systems modeled deliver 0.35 air changes per hour continuously, regardless of actual infiltration or occupant window-opening behavior. Based on the assumptions and analysis described in this report, we recommend independently ducted multi-port supply ventilation in all climates except cold because this strategy provides the safety and health benefits of positive indoor pressure as well as the ability to dehumidify and filter ventilation air. In cold climates, we recommend that multi-port supply ventilation be balanced by a single-port exhaust ventilation fan, and that builders offer balanced heat-recovery ventilation to buyers as an optional upgrade. For builders who continue to install forced-air integrated supply ventilation, we recommend ensuring ducts are airtight or in conditioned space, installing a control that automatically operates the forced-air fan 15-20 minutes during each hour that the fan does not operate for heating or cooling, and offering ICM forced-air fans to home buyers as an upgrade.

  15. Sensor-based demand controlled ventilation

    Energy Technology Data Exchange (ETDEWEB)

    De Almeida, A.T. [Universidade de Coimbra (Portugal). Dep. Eng. Electrotecnica; Fisk, W.J. [Lawrence Berkeley National Lab., CA (United States)

    1997-07-01

    In most buildings, occupancy and indoor pollutant emission rates vary with time. With sensor-based demand-controlled ventilation (SBDCV), the rate of ventilation (i.e., rate of outside air supply) also varies with time to compensate for the changes in pollutant generation. In other words, SBDCV involves the application of sensing, feedback and control to modulate ventilation. Compared to ventilation without feedback, SBDCV offers two potential advantages: (1) better control of indoor pollutant concentrations; and (2) lower energy use and peak energy demand. SBDCV has the potential to improve indoor air quality by increasing the rate of ventilation when indoor pollutant generation rates are high and occupants are present. SBDCV can also save energy by decreasing the rate of ventilation when indoor pollutant generation rates are low or occupants are absent. After providing background information on indoor air quality and ventilation, this report provides a relatively comprehensive discussion of SBDCV. Topics covered in the report include basic principles of SBDCV, sensor technologies, technologies for controlling air flow rates, case studies of SBDCV, application of SBDCV to laboratory buildings, and research needs. SBDCV appears to be an increasingly attractive technology option. Based on the review of literature and theoretical considerations, the application of SBDCV has the potential to be cost-effective in applications with the following characteristics: (a) a single or small number of dominant pollutants, so that ventilation sufficient to control the concentration of the dominant pollutants provides effective control of all other pollutants; (b) large buildings or rooms with unpredictable temporally variable occupancy or pollutant emission; and (c) climates with high heating or cooling loads or locations with expensive energy.

  16. Review of Residential Ventilation Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Armin Rudd

    2005-08-30

    This paper reviews current and potential ventilation technologies for residential buildings, including a variety of mechanical systems, natural ventilation, and passive ventilation. with particular emphasis on North American climates and construction.

  17. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    V/Q scan; Ventilation/perfusion scan; Lung ventilation/perfusion scan ... A pulmonary ventilation/perfusion scan is actually two tests. They may be done separately or together. During the perfusion scan, a health care provider injects ...

  18. A secondary source configuration for control of a ventilation fan noise in ducts

    OpenAIRE

    Čudina, Mirko; Prezelj, Jurij

    2015-01-01

    The main noise source in heating, ventilation, and air conditioning systems is usually a ventilating fan. Noise, generated by the ventilating fan is transmitted through the duct into the living and working environment. A typical fan noise spectrum consists of a broadband noise, which is superimposed with pure tones. Different methods are available to reduce a transmission of such noise from the ventilating fan into the living and working environment. In this article it is demonstrated how a f...

  19. On analysis of operating efficiency of autonomous ventilation systems

    Directory of Open Access Journals (Sweden)

    Kostuganov Arman

    2017-01-01

    Full Text Available The paper deals with the causes and consequences of malfunctioning of natural and mechanical ventilation systems in civil buildings of Russia. Furthermore it gives their classification and analysis based on the literature review. On the basis of the analysis technical solutions for improving the efficiency of ventilation systems in civil buildings are summarized and the field of their application is specified. Among the offered technical solutions the use of autonomous ventilation systems with heat recovery is highlighted as one of the most promising and understudied. Besides it has a wide range of applications. The paper reviews and analyzes the main Russian and foreign designs of ventilation systems with heat recovery that are mostly used in practice. Three types of such systems: UVRK-50, Prana-150, ТеFо are chosen for consideration. The sequence of field tests of selected autonomous ventilation systems have been carried out in order to determine the actual air exchange and efficiency of heat recovery. The paper presents the processed results of the research on the basis of which advantages and disadvantages of the tested ventilation systems are identified and recommendations for engineering and manufacturing of new design models of autonomous ventilation systems with heat recovery are formulated.

  20. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation (BSC), Somerville, MA (United States); Lstiburek, J. [Building Science Corporation (BSC), Somerville, MA (United States); Bergey, D. [Building Science Corporation (BSC), Somerville, MA (United States)

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  1. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    both thermal comfort and energy efficient aspects. The present study aims to characterize the air distribution and thermal comfort in the rooms with diffuse ceiling ventilation. Both the stand-alone ventilation system and its integration with a radiant ceiling system are investigated. This study also...

  2. Mecânica respiratória de pacientes neurocríticos sob ventilação mecânica submetidos à umidificação aquosa aquecida e a um modelo de filtro trocador de calor Respiratory mechanics of neurological patients undergoing mechanical ventilation under water heated humidifier and a heat exchanger filter model

    Directory of Open Access Journals (Sweden)

    Tiago Branco Siqueira

    2010-09-01

    Full Text Available OBJETIVOS: Em pacientes sob ventilação mecânica, dispositivos de umidificação são utilizados para aquecer e umidificar o gás inspirado. O aquecimento e umidificação do gás inspirado podem prevenir complicações associadas ao ressecamento da mucosa respiratória, como a formação de tampão mucoso e oclusão do tubo endotraqueal. Com esse objetivo, dois dispositivos têm sido comumente utilizados: os umidificadores aquosos aquecidos e os filtros trocadores de calor e umidade. O objetivo deste estudo foi comparar o efeito da utilização do umidificador aquoso aquecido e de um modelo de filtro trocador de calor e umidade sobre a mecânica respiratória de pacientes neurocríticos sob ventilação mecânica. MÉTODOS: Trata-se de um ensaio clínico, cruzado e randomizado, onde 31 pacientes neurocríticos sob ventilação mecânica foram submetidos de forma aleatória às duas formas de umidificação. Foram avaliados o volume corrente expirado, pico de fluxo inspiratório, pico de fluxo expiratório, complacência estática, complacência dinâmica e resistência do sistema respiratório. Para análise estatística dos resultados obtidos foram utilizados os testes de Kolmogorov-Smirnov e t-Student para amostras pareadas, considerando-se a significância estatística quando observado um valor de p OBJECTIVES: In mechanically ventilated patients, humidifier devices are used to heat and moisturize the inspired gas. Heating and humidifying inspired gas may prevent complications associated with the respiratory mucosa dryness such as mucus plugging and endotracheal tube occlusion. Two devices have been commonly used to this, either heated humidifier or the heat moisture exchange filter. This study aimed to compare the effects of the heated humidifier and a model of heat moisture exchange filter on respiratory mechanics in mechanically ventilated neurological patients. METHODS: This was a randomized crossover trial, involving 31 neurological

  3. Research on Green Building Material Course for Heating Ventilation and Air-conditioning Major%面向暖通空调专业的绿色建筑材料课程教学研究

    Institute of Scientific and Technical Information of China (English)

    王军

    2016-01-01

    绿色建筑材料作为暖通空调专业的一门新课程,实施本课程的教学对拓展该专业学生的知识面,提高其综合素质和培养创新能力具有重要作用。全面阐述了绿色建筑材料课程的内容体系、知识要点、课程特点和所需要的新型教学模式,以此为开展绿色建筑材料课程的教学工作提供一定的参考和指导。%Green building material is one new course of heating ventilation and air-conditioning major. Teaching this course may play important role for expanding students’ scope of knowledge, improving their comprehensive quality and cultivating their innovation ability. The content framework, content main points of green building material course and needed new type teaching patterns were elaborating in this present study, which may provide some reference and guidance for carrying out teaching green building material course.

  4. Ventilation rates and health

    DEFF Research Database (Denmark)

    Sundell, Jan; Levin, H; Nazaroff, W W

    2011-01-01

    The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates...... and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes...... studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants...

  5. CFD and Ventilation Research

    DEFF Research Database (Denmark)

    Li, Y.; Nielsen, Peter V.

    2011-01-01

    There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part of scienti......There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part...... of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize...... analysis in ventilation research, rather it has become an increasingly important partner....

  6. Improving comfort and health with personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants¿ health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfil the above requirements. This paper reviews...

  7. Ventilation and Heat Dissipation of Construction Integration PV Modules%建筑一体化太阳能光伏组件的通风散热分析

    Institute of Scientific and Technical Information of China (English)

    邬振武

    2012-01-01

    More and more attention has been paid to the development and utilization of green solar energy,especially the utilization of integrative solar architecture technology.These types of PV modules are conventionally installed fixedly,but due to various conditional limitations in installation and design,fixed PV modules leads to the problem in ventilation and heat dissipation,especially the underside of PV modules.In combination with the PV module layout of Shanghai Hongqiao Railway Station,the computational fluid dynamics(CFD) software was used to simulate the heat dissipation of various module layouts,and some optimization suggestions are proposed,with a view to providing some reference for solving this problem.%作为绿色能源,太阳能的开发利用日益受到人们的重视,而与建筑一体化的太阳能开发利用型式,更是得到了大力发展。该型式的光伏组件大多数采用固定式的安装方式,由于在安装和设计时受到种种条件限制,固定式光伏组件通风散热问题不易解决,尤其是下侧板面,问题更为严峻。结合上海虹桥高铁火车站屋面光伏组件的布置,利用CFD(计算流体力学)模拟软件对不同组件布置型式进行散热模拟,并给出优化建议,以期为解决组件的散热问题提供参考。

  8. Comparison of physical performances of the ventilation systems in low-energy residential houses

    Energy Technology Data Exchange (ETDEWEB)

    Maier, T. [Buero V. Maier, Hoechstadt, Erlangen (Germany); Krzaczek, M.; Tejchman, J. [Gdansk University of Technology, Faculty of Civil and Environmental Engineering, 80-952 Gdansk-Wrzeszcz, Narutowicza 11/12 (Poland)

    2009-03-15

    The paper presents experimental results of the effect of ventilation systems in modern residential low-energy houses on thermal and humid conditions, heat consumption and perception of thermal comfort and air quality by their residents. Practical projects of modern residential houses with various ventilation systems which realize thermal, humid and psycho-physical comfort were worked out. To analyze the influence of ventilation systems on human comfort, results of questionnaires and comprehensive experimental measurements were taken into account. For measurements, 22 identical residential houses in Germany were chosen where 4 various ventilation systems were installed: gravitational (natural) ventilation, air heating system, mechanical ventilation with in- and out-leading air elements and a function of heat recovery and mechanical ventilation with single ventilators. The following parameters were measured in test units: relative air humidity, concentration of CO{sub 2} in the air, air temperature, consumption of electricity, gas and heat, working time of the window opening, working time of the mechanical ventilation and number of residents. Advantages and disadvantages of ventilation systems were outlined. Experimental results were evaluated. Relationships between ventilation systems and thermal comfort were discussed by taking into account opinions of house residents. (author)

  9. Tendon repair

    Science.gov (United States)

    Repair of tendon ... Tendon repair can be performed using: Local anesthesia (the immediate area of the surgery is pain-free) ... a cut on the skin over the injured tendon. The damaged or torn ends of the tendon ...

  10. Experimental Assessment of Mechanical Night Ventilation on Inner Wall Surfaces

    DEFF Research Database (Denmark)

    Wenhui, Ji; Heiselberg, Per Kvols; Wang, Houhua;

    2016-01-01

    The cooling potential of night ventilation largely depends on the heat exchange at the internal room surfaces. During night time, increased heat transfer on a vertical wall is expected due to cool supply air that flows along the internal wall surface from the top of the wall. This paper presents ...... an experimental study of the cooling of wall surfaces in a test room by mechanical night-time ventilation. Significant improvement of indoor thermal environment is presented resulting from the enhanced internal convection heat transfer.......The cooling potential of night ventilation largely depends on the heat exchange at the internal room surfaces. During night time, increased heat transfer on a vertical wall is expected due to cool supply air that flows along the internal wall surface from the top of the wall. This paper presents...

  11. On application of heating ventilation air-conditioner energy-saving issue and ground source heat pump%谈暖通空调节能问题与地源热泵的实际应用

    Institute of Scientific and Technical Information of China (English)

    黄长晖

    2012-01-01

    针对暖通空调:市能问题进行了研究,结合实际案例介绍了地源热泵在工程项目中的应用,通过与以城市供热为热源的室内散热器取暖方案进行对比分析,得出地源热泵系统能够有效解决空调系统节能问题,值得推广。%The paper researches the energy-saving issue of heating air-conditioner, introduces the application of the ground source heat pump in the engineering program by combining with the factual cases, undertakes the comparative analysis of the heating scheme for the indoor radiator which regards the urban heating supply as the source, and concludes the ground source heat pump system can solve the energy-saving issue of the air-conditioner system, so it can be further applied.

  12. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... height is examined by means of full-scale measurements. A breathing thermal manikin is used to simulate a person. It is found that the flow in the boundary layer around a person is able to a great extent to entrain and transport air from below the breathing zone. In the case of non-passive, heated...... in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation...

  13. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  14. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark R.

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 {micro}m were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on

  15. Energy Use Consequences of Ventilating a Net-Zero Energy House.

    Science.gov (United States)

    Ng, Lisa C; Payne, W Vance

    2016-03-05

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved

  16. Why We Ventilate

    Energy Technology Data Exchange (ETDEWEB)

    Logue, Jennifer M.; Sherman, Max H.; Price, Phil N.; Singer, Brett C.

    2011-09-01

    It is widely accepted that ventilation is critical for providing good indoor air quality (IAQ) in homes. However, the definition of"good" IAQ, and the most effective, energy efficient methods for delivering it are still matters of research and debate. This paper presents the results of work done at the Lawrence Berkeley National Lab to identify the air pollutants that drive the need for ventilation as part of a larger effort to develop a health-based ventilation standard. First, we present results of a hazard analysis that identified the pollutants that most commonly reach concentrations in homes that exceed health-based standards or guidelines for chronic or acute exposures. Second, we present results of an impact assessment that identified the air pollutants that cause the most harm to the U.S. population from chronic inhalation in residences. Lastly, we describe the implications of our findings for developing effective ventilation standards.

  17. Home Ventilator Guide

    Science.gov (United States)

    ... fit the ventilator under the seat in front. Second, its protected electronic panel prevents the settings from being changed inadvertently. Third, the Trilogy has six hours of battery life – three hours of internal battery and three hours ...

  18. Ventilation in medium-sized and large boiler houses; Ventilation i medelstora och stoerre pannhus

    Energy Technology Data Exchange (ETDEWEB)

    Grotherus, Dan [AaF Installation AB, Oerebro (Sweden); Larsson, Tord [Oerebro Univ. (Sweden). Dept. of Technology

    2005-04-01

    The purpose of this report is to exemplify and clarify the need for ventilation in medium-sized and large boiler houses. We will furthermore present some recommendations, guidelines and advice for the design and construction of a boiler house ventilation system to the plant owners and suppliers of equipment. Boiler house ventilation can be performed in different ways using mechanical or natural ventilation. The solution to be chosen depends on the following factors: Working environment requirements and a necessity to control temperature and pressure in the boiler house; The design of the boiler plant and house; The need for combustion air; The investment expenditure as well as operation and maintenance costs. Mechanical ventilation should be chosen if the aim is a controllable 'climate'. The mechanical ventilation can be either centrally situated or distributed with many aggregates in the boiler house. Centrally situated ventilation equipment will give a higher accessibility and lower maintenance costs than a distributed ventilation system. If the boiler house is designed with natural ventilation the air and flue gas fans will be the only ones installed. In this case temperature and pressure inside the boiler house will be difficult to control. The design factor for the ventilation plant in a boiler house is in most cases the demand to cool the air inside the boiler house to approximately 45 deg C. This is the highest temperature allowed by the Occupational Safety and Health Act in a work environment where the boiler operator is working alone. The air flow which is required for the combustion is normally less than the air flow needed to cool the air in the boiler house. The supply air which is cooling the air inside the boiler house should be supplied on several different levels to attain an efficient cooling. If the combustion air is taken from the heated indoor air the boiler house will work as a heat reclaimer. The difference between outdoor and indoor

  19. Conventional mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Tobias Joseph

    2010-01-01

    Full Text Available The provision of mechanical ventilation for the support of infants and children with respiratory failure or insufficiency is one of the most common techniques that are performed in the Pediatric Intensive Care Unit (PICU. Despite its widespread application in the PICUs of the 21st century, before the 1930s, respiratory failure was uniformly fatal due to the lack of equipment and techniques for airway management and ventilatory support. The operating rooms of the 1950s and 1960s provided the arena for the development of the manual skills and the refinement of the equipment needed for airway management, which subsequently led to the more widespread use of endotracheal intubation thereby ushering in the era of positive pressure ventilation. Although there seems to be an ever increasing complexity in the techniques of mechanical ventilation, its successful use in the PICU should be guided by the basic principles of gas exchange and the physiology of respiratory function. With an understanding of these key concepts and the use of basic concepts of mechanical ventilation, this technique can be successfully applied in both the PICU and the operating room. This article reviews the basic physiology of gas exchange, principles of pulmonary physiology, and the concepts of mechanical ventilation to provide an overview of the knowledge required for the provision of conventional mechanical ventilation in various clinical arenas.

  20. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... removal effectiveness (CRE) and local air change index was measured in order to characterize ventilation effectiveness in the occupied zone. Acceptable thermal comfort was found in most experiments; however, air temperature differences higher than 3 °C occurred when floor cooling was combined...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  1. Bladder exstrophy repair

    Science.gov (United States)

    Bladder birth defect repair; Everted bladder repair; Exposed bladder repair; Repair of bladder exstrophy ... Bladder exstrophy repair involves two surgeries. The first surgery is to repair the bladder and the second one is to attach ...

  2. Solar assisted ventilation tower, Frederiksberg[Denmark]; Ventilationsanlaeggenes betydning for ejendommens varmeforbrug. Delrapport 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-04-01

    The project has demonstrated a building integrated ventilation system with the ducts system installed outside the facade. The air ducts are installed in a solar tower parallel to the staircases in the courtyard. The towers utilise the solar energy for preheating the ventilation air. An air handling unit with counterflow heat exchanger is installed in the roof space. The system is designed for old building block, which are going to be renovated with mechanical ventilation. The system saves room space for the installations of the ventilation ducts. The monitoring of the system performance shows energy saving of 40% caused by new windows, individual heat meters and ventilation with heat recovery and solar tower. The system efficiency of the solar tower is high compared with other traditional solar wall constructions. The ventilation system is designed with a very low electricity consumption of the fans. The monitored electricity consumption is 22 W per dwellings. (au)

  3. Cooling of the Building Structure by Night-time Ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai

    , architects and engineers are still hesitant to apply passive cooling techniques. The basic concept of night-time ventilation involves cooling the building structure overnight in order to provide a heat sink during the occupancy period. As this requires a sufficiently high temperature difference between...... a building energy simulation program (HELIOS), and the effect of different parameters such as building construction, heat gains, air change rates, heat transfer coefficients and climatic conditions on the number of overheating degree hours (operative room temperature >26 °C) was evaluated. Besides climatic...... air flow rates and the possibility of a cold air jet flowing along the ceiling, but the magnitude of these effects is hard to predict. Heat transfer during night-time ventilation in case of mixing and displacement ventilation has been investigated in a full scale test room. The performance of night...

  4. Experimental Assessment of Mechanical Night Ventilation on Inner Wall Surfaces

    DEFF Research Database (Denmark)

    Wenhui, Ji; Heiselberg, Per Kvols; Wang, Houhua

    2016-01-01

    The cooling potential of night ventilation largely depends on the heat exchange at the internal room surfaces. During night time, increased heat transfer on a vertical wall is expected due to cool supply air that flows along the internal wall surface from the top of the wall. This paper presents ...

  5. Ultraviolet B retards growth, induces oxidative stress, and modulates DNA repair-related gene and heat shock protein gene expression in the monogonont rotifer, Brachionus sp

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ryeo-Ok [Department of Chemistry, and Research Institute for Natural Sciences, College of Natural Sciences, Hanyang University, Seoul 133-791 (Korea, Republic of); Rhee, Jae-Sung [Department of Molecular and Environmental Bioscience, Graduate School, Hanyang University, Seoul 133-791 (Korea, Republic of); Won, Eun-Ji [Department of Environmental Marine Sciences, College of Science and Technology, Hanyang University, Ansan 426-791 (Korea, Republic of); Lee, Kyun-Woo [Department of Chemistry, and Research Institute for Natural Sciences, College of Natural Sciences, Hanyang University, Seoul 133-791 (Korea, Republic of); Kang, Chang-Mo [Laboratory of Cytogenetics and Tissue Regeneration, Korea Institute of Radiological and Medical Science, Seoul 139-709 (Korea, Republic of); Lee, Young-Mi [Department of Green Life Science, College of Convergence, Sangmyung University, Seoul 110-743 (Korea, Republic of); Lee, Jae-Seong, E-mail: jslee2@hanyang.ac.kr [Department of Chemistry, and Research Institute for Natural Sciences, College of Natural Sciences, Hanyang University, Seoul 133-791 (Korea, Republic of); Department of Molecular and Environmental Bioscience, Graduate School, Hanyang University, Seoul 133-791 (Korea, Republic of)

    2011-02-15

    Ultraviolet B (UV-B) radiation causes direct cellular damage by breakage of DNA strands and oxidative stress induction in aquatic organisms. To understand the effect of UV-B radiation on the rotifer, Brachionus sp., several parameters including 24-h survival rate, population growth rate, and ROS level were measured after exposure to a wide range of UV-B doses. To check the expression of other important inducible genes such as replication protein A (RPA), DNA-dependent protein kinase (DNA-PK), Ku70, Ku80, and heat shock proteins (hsps) after UV-B radiation, we observed dose- and time-dependency at 2 kJ/m{sup 2}. We also examined 13 hsp genes for their roles in the UV-B damaged rotifer. Results showed that UV-B remarkably inhibited the population growth of Brachionus sp. The level of intracellular reactive oxygen species (ROS) was high at 2 kJ/m{sup 2}, suggesting that 2 kJ/m{sup 2} would already be toxic. This result was supported by other enzymatic activities, such as GSH levels, glutathione peroxidase, glutathione S-transferase, and glutathione reductase. For dose dependency, low doses of UV-B radiation (2, 4, and 6 kJ/m{sup 2}) significantly up-regulated the examined genes (e.g. RPA, DNA-PK, Ku70, and Ku80). For the time course study, RPA genes showed immediate up-regulation but returned to basal or lower expression levels compared to the control 3 h after UV-B exposure. The DNA-PK and Ku70/80 genes significantly increased, indicating that they may be involved in repairing processes against a low dose of UV-B exposure (2 kJ/m{sup 2}). At the basal level, the hsp90{alpha}1 gene showed the highest expression, and followed by hsp10, hsp30, hsp60, and hsc70, and hsp90{beta} in adults (w/o egg). In eggs, the hsp10 gene was expressed the highest, and followed by hsp30, hsp27, hsp90{alpha}1, and hsp60 genes. In real-time RT-PCR array on rotifer hsp genes, low doses of UV-B radiation (2 and 4 kJ/m{sup 2}) showed up-regulation of several hsp genes but most of the hsp

  6. Performance potential of mechanical ventilation systems with minimized pressure loss

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2013-01-01

    ventilation systems with minimal pressure loss and minimal energy use. This can provide comfort ventilation and avoid overheating through increased ventilation and night cooling. Based on this concept, a test system was designed for a fictive office building and its performance was documented using building...... simulations that quantify fan power consumption, heating demand and indoor environmental conditions. The system was designed with minimal pressure loss in the duct system and heat exchanger. Also, it uses state-of-the-art components such as electrostatic precipitators, diffuse ceiling inlets and demand......-control ventilation with static pressure set-point reset. All the equipment has been designed to minimize pressure losses and thereby the fan power needed to operate the system. The total pressure loss is 30-75 Pa depending on the operating conditions. The annual average specific fan power is 330 J/m3 of airflow rate...

  7. Experimental Study of Tunnel Fire with Natural Ventilation

    Institute of Scientific and Technical Information of China (English)

    YUAN Zhong-yuan; LEI Bo; CHEN Peng-Yun

    2009-01-01

    The 1/15 reduced-scale experiments using Froude scaling were designed to study the effect on the smoke control efficiency for subway tunnel fires with natural ventilation mode.The propane gas fires with heat release rate 11.48 kW was used,which corresponds to the heat release rate 10 MW in the full-scale tunnel.The temperature distributions under the ceiling were measured by K-type thermocouples to investigate smoke move-ment,and the velocity of smoke in shafts was measured by hot-wire anemometer to obtain the smoke extract amount of ventilation shafts.The results show that the smoke temperature under the ceiling varies with the lon-gitudinal different distance from fire Source.The results also show that the smoke temperature distributions and the smoke control efficiency in tunnel vary with the space between ventilation shafts and vary with the area and the height of ventilation shaft.

  8. Passive Cooling of buildings by night-time ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, Heinrich; Heiselberg, Per

    Due to an overall trend towards an increasing cooling energy demand in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising concept. However, because of uncertainties in thermal comfort predictions, architects and engineers...... are still hesitant to apply passive cooling techniques. As night-time ventilation is highly dependent on climatic conditions, a method for quantifying the climatic cooling potential was developed and the impact of climate warming was investigated. Although a clear decrease was found, significant potential...... will remain, especially if night-time ventilation is applied in combination with other cooling methods. Building energy simulations showed that the performance of night-time ventilation is also affected by the heat transfer at internal room surfaces, as the cooling effect is very limited for heat transfer...

  9. Calculations of energy consumption in ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Kreslins, Andris; Ramata, Anna [Riga Technical University (Latvia)], e-mail: kreslins@rbf.rtu.lv, email: Anna.Ramata@rtu.lv

    2011-07-01

    Energy cost is an important economic factor in the food industry production process. With the rising price of energy, a reduction in energy consumption would greatly impact production and the end product. The aim of this study was to develop a methodology for optimizing energy consumption. A comparison between a traditional ventilation system and a mechanical system was carried out; the necessary enthalpy for heating the air supply and thermal energy consumption were calculated and compared for both systems during the heating season, from October to April, using climatological data for Latvia. Results showed that energy savings of 46% to 87% can be achieved by applying the methodology in the design of industrial buildings; in addition, a well-designed ventilation system increases the workers' productivity. This study presented a methodology which can optimize energy consumption in the food industry sector.

  10. Bicycle helmet ventilation and comfort angle dependence.

    Science.gov (United States)

    Brühwiler, Paul A; Ducas, Charline; Huber, Roman; Bishop, Phillip A

    2004-09-01

    Five modern bicycle helmets were studied to elucidate some of the variations in ventilation performance, using both a heated manikin headform and human subjects (n = 7). Wind speed and head angle were varied to test their influence on the measured steady-state heat exchange (cooling power) in the skull section of the headform. The cooling power transmitted by the helmets varied from about 60% to over 90% of that of the nude headform, illustrating the range of present manufacturer designs. Angling the head forward by 30 degrees was found to provide better cooling power to the skull (up to 25%) for three of the helmets and almost equal cooling power in the remaining two cases. Comparisons of skull ventilation at these angles with human subjects strongly supported the headform results.

  11. Blown away: good ventilation is a bathroom must have

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, V.

    2010-10-15

    Ventilation is an often overlooked component of bathroom design despite its importance. Modern airtight homes have lost their natural ventilation, heightening the need to pay attention to proper mechanical ventilation. A good vent allows steam to exit the house without damaging the bathroom. Increased bathroom sizes require several smaller fans rather than one large one. Poor ventilation can cause not only unpleasant odours but also mould and mildew on surfaces and damage to the actual structure of the home. Ventilation increases the life of fixtures, grout, and tile. Many existing systems in Canada are inadequate. Although mechanical systems may be noisy, they are the best method to move enough air. The Home Ventilation Institute has developed a set of codes using simulated bathrooms, moisture and tracer gas to compare and test fans. A system should provide 8 air changes an hour, or one cubic foot per minute per foot of floor area. For efficiency, the system should be a controlled process and not occupancy-driven. A popular extra feature on ventilation systems is the ability to heat the bathroom while the fan is ventilating. 1 fig.

  12. Experimental Investigation of Ventilation Efficiency in a Dentistry Surgical Room

    Directory of Open Access Journals (Sweden)

    Oladokun Majeed Olaide

    2016-01-01

    Full Text Available As a response to the need to provide an acceptable thermal comfort and air quality in indoor environments, various ventilation performance indicators were developed over the years. These metrics are mainly geared towards air distribution, heat and pollutant removals. Evidence exists of influencing factors on these indicators as centered on ventilation design and operations. Unlike other indoor environments, health care environment requires better performance of ventilation system to prevent an incidence of nosocomial and other hospital acquired illnesses. This study investigates, using in-situ experiments, the ventilation efficiency in a dentistry surgical room. Thermal and hygric parameters were monitored on the air terminal devices and occupied zone over a period of one week covering both occupied and unoccupied hours. The resulting time-series parameters were used to evaluate the room’s ventilation effectiveness. Also, the obtained parameters were benchmarked against ASHRAE 170 (2013 and MS1525 (2014 requirements for ventilation in health care environment and building energy efficiency respectively. The results show that the mean daily operative conditions failed to satisfy the provisions of both standards. Regarding effectiveness, the findings reveal that the surgical room ventilation is ineffective with ventilation efficiency values ranging between 0 and 0.5 indicating air distribution short-circuiting. These results suggest further investigations, through numerical simulation, on the effect of this short-circuiting on thermal comfort, infection risk assessments and possible design improvements, an endeavour that forms our next line of research inquiries.

  13. Application of Ventilation Air Methane Oxidization and Waste Heat Utilization Technology in Shanxi Lu’an Gaohe Coal Mine%乏风氧化及余热利用技术在山西潞安高河煤矿的应用

    Institute of Scientific and Technical Information of China (English)

    贾剑

    2014-01-01

    A large amount of coal mine ventilation air methane was directly exhausted into the atmosPhere,which not only intensified the greenhouse effect,but also caused the energy consumPtion,and if an aPProPriate technology was aPPlied to make full use of the mine ventilation air methane,huge benefits in energy saving and environmental Protection would be Produced. This PaPer described the mine ventilation air methane oxidation and the waste heat utilization technology in the home and abroad, emPhatically described the design and aPPlication of the Power generation Project with the mine ventilation methane oxidation in Lu’an Gaohe Mine in Shanxi Province,including the collecting and mixing system of the mine ventilation air methane,the safe delivery system of low-concentration gas,the oxidation system of the mine ventilation air methane,the utilization system of the waste heat and so on,and analyzed the significance of the successful construction of this Project.%大量煤矿乏风瓦斯的直接排空,在加剧温室效应的同时亦造成能源的浪费,而通过采用合适的技术对乏风瓦斯加以利用,将产生巨大的节能环保效益。介绍了国内外煤矿乏风瓦斯氧化及余热利用技术,重点介绍了山西潞安高河煤矿的乏风瓦斯氧化发电项目的设计及应用情况,包括乏风收集及掺混系统、低浓度瓦斯输送安全保障系统、乏风氧化系统、余热利用系统等,并分析了该项目建设成功的意义。

  14. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    -cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...... is not well structured with this system. These become the motivations in developing the design guide. This design guide aims to establish a systematic understanding of diffuse ceiling ventilation and provide assistance in designing of such a system. The guide is targeted at design engineers, architects...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...

  15. CFD and Ventilation Research

    DEFF Research Database (Denmark)

    Li, Y.; Nielsen, Peter V.

    2011-01-01

    There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part...... of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize...... the growing need for CFD verification and validation, suggest on-going needs for analytical and experimental methods to support the numerical solutions, and discuss the growing capacity of CFD in opening up new research areas. We suggest that CFD has not become a replacement for experiment and theoretical...

  16. Personal Control Over Heating, Cooling and Ventilation

    DEFF Research Database (Denmark)

    Boerstra, Atze; Simone, Angela

    2013-01-01

    This article presents a summary of a Workshop at 11th Clima Wolrd Conference 2013 in Prague. The workshop was organised by REHVA in cooperation with ISIAQ (International Society of Indoor Air Quality and Climate), and chaired by Atze Boerstra and Angela Simone.......This article presents a summary of a Workshop at 11th Clima Wolrd Conference 2013 in Prague. The workshop was organised by REHVA in cooperation with ISIAQ (International Society of Indoor Air Quality and Climate), and chaired by Atze Boerstra and Angela Simone....

  17. New semi-detached home - Combined heating system using a wood-fired storage oven and a balanced ventilation system; Neubau Doppeleinfamilienhaus, Am Birkenweg 8, 6280 Hochdorf - Kombination von Holzspeicherofen und Lueftung in einem Gebaeude im Minergiestandard, Erfolgskontrolle 1999-2000 - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Langenick, I.

    2000-12-15

    This report for the Swiss Federal Office of Energy (SFOE) discusses the results of a performance review for the period 1999 - 2000. A new semi-detached home in Hochdorf, Switzerland, built to 'Minergie' low energy consumption standards, was the subject of the review. The authors state that the combination of a wood-fired storage oven heating system combined with the balanced ventilation system is basically a new concept. The operation of the heating system was monitored during a full heating period, whereby not only the energy-relevant parameters were noted, but also the comfort of the residents. The planning and functioning of the system is discussed. Improvements to the installation are proposed and unsolved problems are mentioned. The extensive measurements carried out by University of Applied Sciences and Architecture in Lucerne, Switzerland, are presented. The report is completed with a comprehensive appendix.

  18. Cellular Stress Failure in Ventilator-injured Lungs

    Science.gov (United States)

    Vlahakis, Nicholas E.; Hubmayr, Rolf D.

    2005-01-01

    The clinical and experimental literature has unequivocally established that mechanical ventilation with large tidal volumes is injurious to the lung. However, uncertainty about the micromechanics of injured lungs and the numerous degrees of freedom in ventilator settings leave many unanswered questions about the biophysical determinants of lung injury. In this review we focus on experimental evidence for lung cells as injury targets and the relevance of these studies for human ventilator-associated lung injury. In vitro, the stress-induced mechanical interactions between matrix and adherent cells are important for cellular remodeling as a means for preventing compromise of cell structure and ultimately cell injury or death. In vivo, these same principles apply. Large tidal volume mechanical ventilation results in physical breaks in alveolar epithelial and endothelial plasma membrane integrity and subsequent triggering of proinflammatory signaling cascades resulting in the cytokine milieu and pathologic and physiologic findings of ventilator-associated lung injury. Importantly, though, alveolar cells possess cellular repair and remodeling mechanisms that in addition to protecting the stressed cell provide potential molecular targets for the prevention and treatment of ventilator-associated lung injury in the future. PMID:15695492

  19. Ventilation efficiencies and thermal comfort results of a desk-edge-mounted task ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Faulkner, D.; Fisk, W.J.; Sullivan, D.P.; Lee, S.M.

    2003-09-01

    In chamber experiments, we investigated the ventilation effectiveness and thermal comfort of a task ventilation system with an air supply nozzle located underneath the front edge of a desk and directing air toward a heated mannequin or a human volunteer seated at the desk. The task ventilation system provided outside air, while another ventilation system provided additional space cooling but no outside air. Test variables included the vertical angle of air supply (-15{sup o} to 45{sup o} from horizontal), and the supply flow rate of (3.5 to 6.5 L s{sup -1}). Using the tracer gas step-up and step-down procedures, the measured air change effectiveness (i.e., exhaust air age divided by age of air in the breathing zone) in experiments with the mannequin ranged from 1.4 to 2.7 (median, 1.8), whereas with human subjects the air change effectiveness ranged from 1.3 to 2.3 (median, 1.6). The majority of the air change effectiveness values with the human subjects were less than values with the mannequin at comparable tests. Similarly, the tests run with supply air temperature equal to the room air temperature had lower air change effectiveness values than comparable tests with the supply air temperature lower ({approx}5 C) than the room air temperature. The air change effectiveness values are higher than typically reported for commercially available task ventilation or displacement ventilation systems. Based on surveys completed by the subjects, operation of the task ventilation system did not cause thermal discomfort.

  20. Demand controlled ventilation; Behovsstyrt ventilasjon

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Henning Holm

    2006-07-01

    The terms CAV and VAV have been known terms for many years in the ventilation business. The terms are also included in building regulations, but the time is now right to focus on demand controlled ventilation (DCV). The new building regulations and the accompanying energy framework underline the need for a more nuanced thinking when it comes to controlling ventilation systems. Descriptions and further details of the ventilation systems are provided (ml)

  1. Creep properties and simulation of weld repaired low alloy heat resistant CrMo and Mo steels at 540 deg C. Sub project 1 - Ex-serviced parent metal and virgin weld metals

    Energy Technology Data Exchange (ETDEWEB)

    Rui Wu; Storesund, Jan; Borggreen, Kjeld; Weilin Zang

    2006-10-15

    Many existing power generating and process plants, where low alloy heat resistant CrMo(V) steels are extensively used for critical components, have exceeded their design lifetime of usually 100,000 hours. Assessment of residual lifetime and extension of economic life by weld repair have become increasingly important and attractive. This project aims at i) performing weld repair and determining the degree of mismatching, ii) evaluating the creep properties of weld repairs, iii) analysing creep behaviour of weld repair and providing necessary data for further reliable simulations of weld repair creep behaviour in long term service, and iv), simulating and assessing lifetime and creep damage evolution of weld repair. Weld repair using 10 CrMo 9 10, 13 CrMo 4 4 and 15 Mo 3 consumables has been carried out in a service-exposed 10 CrMo 9 10 pipe. Creep specimens have been extracted from the service-exposed 10 CrMo 9 10 parent metal (PM), from the virgin 10 CrMo 9 10 weld metal (WM), from the virgin 13 CrMo 4 4 WM as well as from the virgin 15 Mo 3 WM. Iso-thermal uniaxial creep tests have been performed at 540 deg C in air. Pre- and post-metallography are carried out on the selected samples. FEM simulations using obtained creep data are executed. Pre-test metallography shows normal and acceptable weld repairs at given welding conditions. Creep tests demonstrate that the virgin 10 CrMo 9 10, 13 CrMo 4 4 and 15 Mo 3 WMs have apparently longer creep lifetime than the service-exposed CrMo 9 10 PM at higher stresses than 110 MPa. Among the weld metals, the longest creep lifetime is found in 10 CrMo 9 10. Higher creep strength and lower creep strain rate in the weld metals indicate an overmatch weld. At 95 MPa, however, lifetime of 13 CrMo 4 4 WM is surprisingly short (factors which may shorten lifetime are discussed and one more test will start to verify creep strength at low stress) and tests are still running for other two weld metals. More results regarding low stress

  2. Hybrid Ventilation Air Flow Process

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols

    The scope of this annex is therefore to obtain better knowledge of the use of hybrid ventilation technologies. The annex focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on implementation...

  3. Ventilator and viral induced inflammation

    NARCIS (Netherlands)

    Hennus, M.P.

    2013-01-01

    This thesis expands current knowledge on ventilator induced lung injury and provides insights on the immunological effects of mechanical ventilation during viral respiratory infections. The experimental studies in the first part of this thesis improve our understanding of how mechanical ventilation

  4. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  5. Elforbrug til mekanisk ventilation

    DEFF Research Database (Denmark)

    Olufsen, P.

    I Energi 2000 er ventilationsområdet udpeget som et af de områder, hvor der bør tages initiativ til at fremme elbesparelser. I rapporten beskrives og analyseres målinger af elforbruget til ventilation i 12 bygninger, der alle anvendes til administration eller lignende formål. På grundlag af...

  6. Human response to ductless personalized ventilation coupled with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Veselý, Michal; Melikov, Arsen K.

    2012-01-01

    A human subject experiment was carried out to investigate the extent to which ductless personalized ventilation (DPV) in conjunction with displacement ventilation can improve perceived air quality (PAQ) and thermal comfort at elevated room air temperature in comparison with displacement ventilation...... alone. The experimental conditions comprised displacement ventilation alone (room air temperature of 23 °C, 26 °C, 29 °C) and DPV with displacement ventilation (26 °C, 29 °C), both operating at supply air temperatures 3, 5 or 6K lower than room air temperature, as well as mixing ventilation (23 °C, 3 K......). During one hour exposure participants answered questionnaires regarding PAQ and thermal comfort. PAQ was significantly better with DPV than without DPV at the same background conditions. Thermal comfort improved when DPV was used. Combining DPV with displacement ventilation showed the potential...

  7. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P.V.; Hyldgaard, C.E.; Melikov, Arsen Krikor;

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized as a displace......This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... as a displacement flow with a downward direction in areas of the room where no thermal load is present. The system was extended by a personalized ventilation system to study the improved Protection of people in a room. The investigation involved full-scale experiments with two breathing thermal manikins. One...... in the room with increased protection of the occupants. It is shown that personalized ventilation improves the protection of occupants by increasing the personal exposure index....

  8. Determination of the heating temperature of potholes surface on road pavement in the process of repairs using hot asphalt concrete mixes

    Directory of Open Access Journals (Sweden)

    Giyasov Botir Iminzhonovich

    2014-12-01

    Full Text Available In the process of roads construction the necessary transport and operational characteristics should be achieved, which depend on the quality of the applied, material and technologies. Under the loads of transport means and the influence of weather conditions on the road pavement deformations and destructions occur, which lead to worsening of transport and operational characteristics, decrease of operational life of the road and they are often the reason of road accidents. According to the data of the Strategic Research Center of "Rosgosstrah" more than 20 % of road accidents in Russia occur due to bad quality of road pavement. One of the main directions in traffic security control and prolongation of operational life for road pavement of non-rigid type is road works, as a result of which defects of pavement are eliminated and in case of timely repairs of high quality the operational life of the road increases for several years. The most widely used material for non-rigid pavement repairs is hot road concrete mixes and in case of adherence to specifications they provide high quality of works. The authors investigate the problems of hot asphalt concrete mixes for repairs of road surfaces of non-rigid type. The results of the study hot asphalt concrete mix’s temperature regimes are offered in case of repair works considering the temperature delivered to the work site and the ambient temperature depending on the type of mix and class of bitumen.

  9. Hypospadias repair

    Science.gov (United States)

    ... the problem. If the repair is not done, problems may occur later on such as: Difficulty controlling and directing urine stream A curve in the penis during erection Decreased fertility Embarrassment about appearance of penis Surgery ...

  10. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  11. Experimental Assessment of Moisture Transfer in the Vertical Ventilated Channel

    Directory of Open Access Journals (Sweden)

    Musorina Tatyana

    2016-01-01

    Full Text Available This article considers the moisture transfer phenomenon in the vertical ventilated channel. Also the article considers innovative structures for the vertical ventilated channel.The negative factors connected with moisture accumulation and excessive moistening of a heat insulation are given. Optimum design parameters for definition of the most intensive moisture transfer are discovered: systems with and without grooved lines. Influence that existence of technological gaps (grooved lines has on the speed of air flows in a gap is investigated. Dependence of speed on width of the ventilated gap for a design with the opened and closed grooved lines is established empirically. The dehumidification properties of the vertical ventilated channel are described, as well as dependence of mass evaporation rate on time is established. Processes of drying-out in various conditions are compared.

  12. Displacement and air distribution ventilation systems; Verdringingsventilatie- en luchtverdeelsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Van Holten, P. [Solid Air, Amsterdam (Netherlands)

    2009-06-15

    Since an evaporative cooling system uses 100% clean outdoor air; it is ideal for positive displacement ventilation. By using the overpressure inside the building or room, windows and doors can be opened without affecting the controlled room temperature. The combination of positive displacement ventilation/balance ventilation with heat recovery is a very attractive solution. In this article you will find a brief explanation of the operation, application and basic principles of positive displacement ventilation. [Dutch] Verdampingskoeling leent zich in het bijzonder voor verdringingsventilatie dankzij het gebruik van 100% buitenlucht. Gebruikmakend van overdruk kunnen daarbij ramen en deuren worden geopend zonder dat de temperatuur hierdoor sterk wordt beinvloed. De combinatie verdringingsventilatie/balansventilatie met WTW, zoals in De Vijfhoek, is daarbij een voor de hand liggende optie. In dit artikel worden de basisprincipes van verdringingsventilatie, alsmede de werking en toepassing hiervan, toegelicht.

  13. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  14. Creep properties and simulation of weld repaired low alloy heat resistant CrMo and Mo steels at 540 deg C. Sub-project 2 - Ex-serviced 2.25Cr1M0 weld metal and cross weld repairs

    Energy Technology Data Exchange (ETDEWEB)

    Rui Wu; Storesund, Jan; Borggreen, Kjeld; Feilitzen, Carl von

    2007-12-15

    Weld repair has been carried out in an ex-serviced 10 CrMo 9 10 pipe by using 10 CrMo 9 10, 13 CrMo 4 4 and 15 Mo 3 consumables. Application of current welding procedure and consumables results in an over matched weld repair. This is verified by both creep tests and the creep simulations at even lower stresses than tested. Creep specimens have been extracted from ex-serviced 10 CrMo 9 10 parent metal (PM) and weld metal (WM), from virgin 10 CrMo 9 10 WM, from virgin 13 CrMo 4 4 WM, and from virgin 15 Mo 3 WM. In addition, cross weld specimens including weld metal, heat affected zone (HAZ) and parent metal have been taken from the ex-serviced 10 CrMo 9 10 weld joint, and from three weld repairs. In total, there are nine test series. The sequence of creep lifetime at 540 deg C at given stresses is; virgin 10 CrMo 9 10 weld metal > virgin 15 Mo 3 weld metal approx virgin 13 CrMo 4 4 weld metal approx ex-serviced 10 CrMo 9 10 weld metal >> ex-serviced 10 CrMo 9 10 parent metal > ex-serviced 10 CrMo 9 10 cross weld approx 10 CrMo 9 10 cross weld repair approx 13 CrMo 4 4 cross weld repair approx and 15 Mo 3 cross weld repair. All the series show good creep ductility. The ex-serviced 10 CrMo 9 10 parent metal shows a creep lifetime about one order of magnitude shorter than that for both the virgin parent metal and the ex-serviced 10 CrMo 9 10 weld metal, independent of stresses. Differences in creep lifetime among the ex-serviced 10 CrMo 9 10 cross weld and other cross weld repairs are negligible, simply because rupture always occurred in the ex-serviced 10 CrMo 9 10 parent metal, approximately 10 mm from HAZ, for all the cross welds. Necking is frequently observed in the ex-serviced 10 CrMo 9 10 parent metal at the opposite side of the fracture. Creep damage to a large and a small extend is found adjacent to the fracture and at the necking area, respectively. Other parts of the weld joint like weld metal and HAZ are damage-free, independent of stress, weld metal and

  15. Impact of personalized ventilation combined with chilled ceiling on eye irritation symptoms

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Marcol, Bartosz; Kaczmarczyk, Jan

    2014-01-01

    Personalized ventilation (PV) improves inhaled air quality, because it provides fresh air to each workstation and directly to occupant’s breathing zone. The PV alone can be used for room ventilation when applied in conjunction with ceiling radiant cooling system, which removes sensible heat loads...

  16. High Frequency Oscillatory Ventilation

    Directory of Open Access Journals (Sweden)

    AC Bryan

    1996-01-01

    Full Text Available High frequency oscillatory (HFO ventilation using low tidal volume and peak airway pressures is extremely efficient at eliminating carbon dioxide and raising pH in the newborn infant with acute respiratory failure. Improvement in oxygenation requires a strategy of sustained or repetitive inflations to 25 to 30 cm H2O in order to place the lung on the deflation limb of the pressure-volume curve. This strategy has also been shown to decrease the amount of secondary lung injury in animal models. Experience of the use of HFO ventilation as a rescue therapy as well as several published controlled trials have shown improved outcomes and a decrease in the use of extracorporeal membrane oxygenation when it has been used in newborns.

  17. Adult patient with pulmonary agenesis: focusing on one-lung ventilation during general anesthesia.

    Science.gov (United States)

    Yu, Yuetian; Zhu, Cheng; Qian, Xiaozhe; Gao, Yuan; Zhang, Zhongheng

    2016-01-01

    Congenital pulmonary agenesis is a rare condition with high mortality. Mechanical ventilation in these patients is challenging and there has no such case been reported in the literature. We reported a 61-year-old female with lung agenesis who presented to our hospital with pneumonia and pelvic mass. In the past, she had undergone repairing of atrial septal defect and mitral valve forming surgery at 6-year-old. Thereafter she had remained asymptomatic until this time of hospital admission. The patient underwent operation for the pelvic mass with one-lung ventilation (OLV) under general anesthesia. We highlighted the use of protective ventilation (PV) strategy during OLV.

  18. Femoral hernia repair

    Science.gov (United States)

    Femorocele repair; Herniorrhaphy; Hernioplasty - femoral ... During surgery to repair the hernia, the bulging tissue is pushed back in. The weakened area is sewn closed or strengthened. This repair ...

  19. Undescended testicle repair

    Science.gov (United States)

    Orchidopexy; Inguinal orchidopexy; Orchiopexy; Repair of undescended testicle; Cryptorchidism repair ... first year of life without treatment. Undescended testicle repair surgery is recommended for patients whose testicles do ...

  20. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  1. Development of a computer code to predict a ventilation requirement for an underground radioactive waste storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.J.; Dalpiaz, E.L. [ICF Kaiser Hanford Co., Richland, WA (United States)

    1997-08-01

    Computer code, WTVFE (Waste Tank Ventilation Flow Evaluation), has been developed to evaluate the ventilation requirement for an underground storage tank for radioactive waste. Heat generated by the radioactive waste and mixing pumps in the tank is removed mainly through the ventilation system. The heat removal process by the ventilation system includes the evaporation of water from the waste and the heat transfer by natural convection from the waste surface. Also, a portion of the heat will be removed through the soil and the air circulating through the gap between the primary and secondary tanks. The heat loss caused by evaporation is modeled based on recent evaporation test results by the Westinghouse Hanford Company using a simulated small scale waste tank. Other heat transfer phenomena are evaluated based on well established conduction and convection heat transfer relationships. 10 refs., 3 tabs.

  2. Performance of radiant cooling ceiling combined with personalized ventilation in an office room: identification of thermal conditions

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    The paper compares thermal environment conditions created by four HVAC systems: mixing ventilation, chilled ceiling combined with mixing ventilation, chilled ceiling with mixing ventilation and personalized ventilation, and chilled ceiling combined with personalized ventilation only. Measurements...... were performed in a test room arranged as an office with 2 workstations and 2 seating occupants resembled by thermal manikins. Heat gain of 66-72 W/m2 was simulated in the room (occupants, computers, lighting, solar gain). The air temperature in the chamber was maintained at 26°C and 28°C. Personalized...

  3. Pulmonary mechanics during mechanical ventilation.

    Science.gov (United States)

    Henderson, William R; Sheel, A William

    2012-03-15

    The use of mechanical ventilation has become widespread in the management of hypoxic respiratory failure. Investigations of pulmonary mechanics in this clinical scenario have demonstrated that there are significant differences in compliance, resistance and gas flow when compared with normal subjects. This paper will review the mechanisms by which pulmonary mechanics are assessed in mechanically ventilated patients and will review how the data can be used for investigative research purposes as well as to inform rational ventilator management.

  4. Mechanical ventilation in neurosurgical patients

    Directory of Open Access Journals (Sweden)

    Keshav Goyal

    2013-01-01

    Full Text Available Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical patient requiring artificial support of the respiration.

  5. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  6. Design Principles for Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation....... The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples....

  7. Application of the Terrestrial Heat Recycling Technology in Highway Repair%高速公路维修就地热再生技术应用探讨

    Institute of Scientific and Technical Information of China (English)

    张俊豪

    2014-01-01

    把就地热再生技术应用在施工现场中,可以保证工程质量,控制施工成本。本文主要介绍了就地热再生技术的原理和优势、沥青路热再生技术在施工中的应用、热再生配比、高速公路施工的重难点。%The application of terrestrial heat recycling techn- ology in construction site can ensure the engineering quality and control construction cost. This paper mainly introduced the principles and the advantages of the terrestrial heat recycling technology and the terrestrial heat recycling technology in asp- halt road construction, the ratio of regenerated heat and di- fficulties and stresses in highway construction.

  8. Displacement ventilation in lecture halls

    OpenAIRE

    Egorov, Artem

    2013-01-01

    This thesis considers several important goals. The main purpose is to see how displacement ventilation sys-tem works in the lecture hall of M-building and compare obtained results with D2 and Indoor Climate Classi-fication. The second one is to analyze the function of the ventilation system. The last one is to realize when displacement ventilation is preferable to mixing ventilation. Analysis of the system was carried out with instruments from MUAS HVAC laboratory. In lecture hall were me...

  9. Intestinal obstruction repair

    Science.gov (United States)

    Repair of volvulus; Intestinal volvulus - repair; Bowel obstruction - repair ... Intestinal obstruction repair is done while you are under general anesthesia . This means you are asleep and DO NOT feel pain. ...

  10. Aortic aneurysm repair - endovascular

    Science.gov (United States)

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... Endovascular aortic repair is done because your aneurysm is very large, growing quickly, or is leaking or bleeding. You may have ...

  11. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  12. Performance of low pressure mechanical ventilation concept with diffuse ceiling inlet for renovation of school classrooms

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    In a great portion of Danish primary schools the mechanical ventilation systems is outdated or simply rely on opening of windows to ventilate the classrooms. This leads to high energy consumption for fans and/or ventilation heat losses and poor indoor environment, as the ventilation systems cannot...... provide a sufficient ventilation rate. A recent study with 750 Danish classrooms show that 56 % had CO2-concentrations over a 1000 ppm, which is the recommended limit by the Danish working environment authority and this adversely affects the performance and well being of the pupils. This paper describes...... a mechanical ventilation concept to lower energy consumption and improve the indoor environment, developed for refurbishment of school classrooms. The performance of the concept is investigated through computer simulations and measurements of energy consumption and indoor environment. The measurements are made...

  13. Influence of Ventilation Ratio on Desiccant Air Conditioning System's Efficiency Performance

    Science.gov (United States)

    Tran, Thien Nha; Akisawa, Atsushi; Kashiwagi, Takao; Hamamoto, Yoshinori

    Ventilation air is a concern for engineers since ventilated air controls indoor air contamination; additional ventilation, however, increases the energy consumption of buildings. The study investigates the energy efficiency performance of the desiccant dehumidification air conditioning system in the context of ventilation for a hot-humid climate such as summer in Japan. The investigation focuses on the variable ratio of ventilation air as required by the application of air conditioning system. The COP of the desiccant air conditioning system is determined. The evaluation is subsequently performed by comparing the desiccant based system with the conventional absorption cooling system and the vapor compression cooling system. Based on 12 desiccant rotor simulations, it is found that the desiccant regeneration temperature required varies between 47°C to 85°C as ventilation ratio increases from 0. 0 to 100%, and up to 52. 5°C as the ventilation ratio achieves 14%. The heat required for regenerating desiccant accounts for 55% and higher of the system's total heat consumption; the system is expected to be energy efficient by using wasted heat from the absorption chiller for desiccant regeneration; and its energy efficiency expands as the ratio of ventilation air rises above 15% compared with the conventional absorption cooling system. The energy efficiency also benefits as the ratio rises beyond 70% against the conventional vapor compression cooling system.

  14. Passive cooling of buildings by night-time ventilation - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Artmann, N.; Manz, H. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heiselberg, P. [Aalborg University, Aalborg (Denmark)

    2008-07-01

    Due to an overall trend towards an increasing cooling energy demand in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising concept. However, because of uncertainties in thermal comfort predictions, architects and engineers are still hesitant to apply passive cooling techniques. As night-time ventilation is highly dependent on climatic conditions, a method for quantifying the climatic cooling potential was developed and the impact of climate warming was investigated. Although a clear temperature decrease was found, significant potential will remain, especially if night-time ventilation is applied in combination with other cooling methods. Building energy simulations showed that the performance of night-time ventilation is also affected by the heat transfer at internal room surfaces, as the cooling effect is very limited due to heat transfer coefficients below about 4 W/m{sup 2}K. Heat transfer during night-time ventilation in case of mixing and displacement ventilation was investigated in a full scale test room at Aalborg University. In the experiments the temperature efficiency of the ventilation was determined. Based on the previous results a method for estimating the potential for cooling by night-time ventilation at an early stage of design was developed. (author)

  15. Passive cooling of buildings by night-time ventilation - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Artmann, N.; Manz, H. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heiselberg, P. [Aalborg University, Aalborg (Denmark)

    2008-07-01

    Due to an overall trend towards an increasing cooling energy demand in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising concept. However, because of uncertainties in thermal comfort predictions, architects and engineers are still hesitant to apply passive cooling techniques. As night-time ventilation is highly dependent on climatic conditions, a method for quantifying the climatic cooling potential was developed and the impact of climate warming was investigated. Although a clear temperature decrease was found, significant potential will remain, especially if night-time ventilation is applied in combination with other cooling methods. Building energy simulations showed that the performance of night-time ventilation is also affected by the heat transfer at internal room surfaces, as the cooling effect is very limited due to heat transfer coefficients below about 4 W/m{sup 2}K. Heat transfer during night-time ventilation in case of mixing and displacement ventilation was investigated in a full scale test room at Aalborg University. In the experiments the temperature efficiency of the ventilation was determined. Based on the previous results a method for estimating the potential for cooling by night-time ventilation at an early stage of design was developed. (author)

  16. Monitoring during Mechnical Ventilation

    Directory of Open Access Journals (Sweden)

    Dean Hess

    1996-01-01

    Full Text Available Monitoring is a continuous, or nearly continuous, evaluation of the physiological function of a patient in real time to guide management decisions, including when to make therapeutic interventions and assessment of those interventions. Pulse oximeters pass two wavelengths of light through a pulsating vascular bed and determine oxygen saturation. The accuracy of pulse oximetry is about ±4%. Capnography measures carbon dioxide at the airway and displays a waveform called the capnogram. End-tidal PCO2 represents alveolar PCO2 and is determined by the ventilation-perfusion quotient. Use of end-tidal PCO2 as an indication of arterial PCO2 is often deceiving and incorrect in critically ill patients. Because there is normally very little carbon dioxide in the stomach, a useful application of capnography is the detection of esophageal intubation. Intra-arterial blood gas systems are available, but the clinical impact and cost effectiveness of these is unclear. Mixed venous oxygenation (PvO2 or SvO2 is a global indicator of tissue oxygenation and is affected by arterial oxygen content, oxygen consumption and cardiac output. Indirect calorimetry is the calculation of energy expenditure and respiratory quotient by the measurement of oxygen consumption and carbon dioxide production. A variety of mechanics can be determined in mechanically ventilated patients including resistance, compliance, auto-peak end-expiratory pressure (PEEP and work of breathing. The static pressure-volume curve can be used to identify lower and upper infection points, which can be used to determine the appropriate PEEP setting and to avoid alveolar overdistension. Although some forms of monitoring have become a standard of care during mechanical ventilation (eg, pulse oximetry, there is little evidence that use of any monitor affects patient outcome.

  17. Probable causes of damage of heat-exchange tubes of low-pressure-exchanges of PND-3 type and repair methods

    Science.gov (United States)

    Trifonov, N. N.; Esin, S. B.; Nikolaenkova, E. K.; Sukhorukov, Yu. G.; Svyatkin, F. A.; Sintsova, T. G.; Modestov, V. S.

    2017-08-01

    The structures of low-pressure heaters (LPH), which are installed at nuclear power plants with the K-1000-60/1500 type turbine plants are considered. It was revealed that only the PND-3 type low-pressure heaters have the damages of the heat exchange tubes. For a short operation life, the number of the damaged heat-exchange tubes of PND-3 is approximately 50 pcs for Kalinin NPP and 100-150 pcs for Balakovo NPP. The low-pressure heaters were manufactured at AO Ural Plant of Chemical Machine-Building "Uralkhimmash," OAO Taganrog Boiler-Making Works "Krasny Kotelshchik," and Vitkovice Machinery Group, but the damage nature of the heat-exchange tubes is identical for all PND-3. The damages occur in the place of passage of the heat exchange tubes through the first, the second, and the third partitions over the lower tube plate (the first path of the turbine condensate). Hydraulic shocks can be one of the possible causes of the damage of the heat-exchange tubes of PND-3. The analysis of the average thermal and dynamic loads of the tube systems of PND-1-PND-4 revealed that PND-3 by the thermal power are loaded 1.4-1.6 times and by the dynamic effects are loaded 1.8-2.0 times more than the remaining LPHs. Another possible cause of damage can be the cascaded drain of the separate into PND-4 and then through the drainage heat exchange into PND-3. An additional factor can be the structure of the condensate drainage unit. The advanced system of the heating steam flow and pumping scheme of the separate drain using the existing drainage pumps of PND-3 for K-1000-60/1500 turbine plants for Balakovo and Kalinin NPPs were proposed. The considered decisions make it possible to reduce the flow rate of the heating steam condensate from PND-3 into PND-4 and the speed of the heating steam in the tube space of PND-3 and eliminate the occurrence of hydraulic shocks and damages of the heat exchanger tubes.

  18. Turbine repair process, repaired coating, and repaired turbine component

    Energy Technology Data Exchange (ETDEWEB)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  19. Solar chimney: A sustainable approach for ventilation and building space conditioning

    Directory of Open Access Journals (Sweden)

    Lal, S.,

    2013-03-01

    Full Text Available The residential and commercial buildings demand increase with rapidly growing population. It leads to the vertical growth of the buildings and needs proper ventilation and day-lighting. The natural air ventilation system is not significantly works in conventional structure, so fans and air conditioners are mandatory to meet the proper ventilation and space conditioning. Globally building sector consumed largest energy and utmost consumed in heating, ventilation and space conditioning. This load can be reduced by application of solar chimney and integrated approaches in buildings for heating, ventilation and space conditioning. It is a sustainable approach for these applications in buildings. The authors are reviewed the concept, various method of evaluation, modelings and performance of solar chimney variables, applications and integrated approaches.

  20. Study of Night Ventilation Efficiency in Urban Environment: Technical and Legal Aspects

    Science.gov (United States)

    Maragogiannis, Konstantinos; Kolokotsa, Dionysia; Maria, Efpraxia-Aithra

    2011-01-01

    Night Ventilation is a critical technique of passive cooling, as it combines a significant decrease of cooling demand and improvement of thermal comfort and indoor air quality. The aim of the present paper is to study the technical and legal aspects of night ventilation in urban climatic conditions. The technical part examines the efficiency of night ventilation techniques for urban residential buildings. Moreover, the influence of urban heat island on the night ventilation effectiveness is studied. Urban heat provokes the degradation of urban air quality and causes changes in the urban area microclimate which reduce the night ventilation effectiveness as a passive cooling technique. Moreover, this paper studies the legal framework of energy efficiency in buildings and pinpoints the institutional deficiencies of the existing regulation regarding energy efficiency and passive cooling techniques

  1. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  2. Displacement ventilation and passive cooling strategies

    Energy Technology Data Exchange (ETDEWEB)

    Carew, P.; Bekker, B. [PJCarew Consulting, Cape Town (South Africa)

    2009-07-01

    Displacement ventilation (DV) is widely used a passive cooling strategy because it requires less air supply for cooling compared to conventional mixing ventilation (MV). DV introduces air at low level and low velocity, and at high supply air temperature, usually around 18 degrees C. The slightly cooler air runs along the floor of a room until it reaches a heat load. The heat load induces a plume of warmer air that rises due to lower density. This induces stratification in room temperature with the occupied area of the room. The air near the ceiling is continually exhausted to prevent a build up of warm air into the occupied zone. This paper demonstrated the impacts of using DV in comparison to MV on the peak capacity, size and humidity levels associated with various passive cooling strategies, informed by the ASHRAE DV guidelines. A generic office building in Johannesburg, South Africa, was used as a model. The paper illustrated the extent to which DV can be used as a passive cooling strategy in spaces that were previously considered as having too high a heat load when calculated using MV system guidelines. A comparison of DV and MV also highlighted the risk of over-design when conventional MV guidelines are used to design cooling sources for DV applications. The DV was shown to significantly lower the amount of supply air needed to serve a room's heat load when compared to MV at the same temperatures. This reduction in air supply impacts the feasibility of using passive cooling strategies in evaporative cooling, 2-stage evaporative cooling, thermal storage and air to ground heat exchangers. However, passive cooling strategies are unlikely to be widely implemented until design guidelines are created by organizations such as ASHRAE. 8 refs., 2 tabs., 15 figs.

  3. Ultrastructural Study of Alveolar Epithelial Type II Cells by High-Frequency Oscillatory Ventilation

    Directory of Open Access Journals (Sweden)

    Xiaofei Qin

    2013-01-01

    Full Text Available Alveolar epithelial type II cells (AECIIs containing lamellar bodies (LBs are alveolar epithelial stem cells that have important functions in the repair of lung structure and function after lung injury. The ultrastructural changes in AECIIs after high-frequency oscillatory ventilation (HFOV with a high lung volume strategy or conventional ventilation were evaluated in a newborn piglet model with acute lung injury (ALI. After ALI with saline lavage, newborn piglets were randomly assigned into five study groups (three piglets in each group, namely, control (no mechanical ventilation, conventional ventilation for 24 h, conventional ventilation for 48 h, HFOV for 24 h, and HFOV for 48 h. The lower tissues of the right lung were obtained to observe the AECII ultrastructure. AECIIs with reduced numbers of microvilli, decreased LBs electron density, and vacuole-like LBs deformity were commonly observed in all five groups. Compared with conventional ventilation groups, the decrease in numbers of microvilli and LBs electron density, as well as LBs with vacuole-like appearance and polymorphic deformity, was less severe in HFOV with high lung volume strategy groups. AECIIs were injured during mechanical ventilation. HFOV with a high lung volume strategy resulted in less AECII damage than conventional ventilation.

  4. Application of Breathing Architectural Members to the Natural Ventilation of a Passive Solar House

    Directory of Open Access Journals (Sweden)

    Kyung-Soon Park

    2016-03-01

    Full Text Available The efficient operation of a passive solar house requires an efficient ventilation system to prevent the loss of energy and provide the required ventilation rates. This paper proposes the use of “breathing architectural members” (BAMs as passive natural ventilation devices to achieve much improved ventilation and insulation performance compared to mechanical ventilation. Considering the importance of evaluating the ventilation and insulation performances of the members, we also propose numerical models for predicting the heat and air movements afforded by the members. The numerical model was validated by comparison with experimental results. The effectiveness of the BAMs was also verified by installation in houses located in an area with warm climate. For this purpose, chamber experiments were performed using samples of the BAMs, as well as numerical simulations to assess natural ventilation and heat load. The main findings of the study are as follows: (1 the one-dimensional chamber experiments confirmed the validity of the numerical models for predicting the heat and air movements afforded by the BAMs. Comparison of the experimental and calculated values for the temperature of air that flowed into the room from outside revealed a difference of less than 5%; (2 observations of the case studies in which BAMs were installed in the ceilings and exterior walls of Tokyo model houses revealed good annual ventilation and energy-saving effects. When BAMs with an opening area per unit area of A = 0.002 m2/m2 were applied to three surfaces, the required ventilation rate was 0.5 ACH (air changes per hour, and this was achieved consistently. Compared to a house with general insulation and conventional mechanical ventilation, heating load was reduced by 15.3%–40.2% depending on the BAM installation points and the differing areas of the house models.

  5. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings

    Directory of Open Access Journals (Sweden)

    Piers MacNaughton

    2015-11-01

    Full Text Available Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person, 30% enhanced ventilation, and 40 cfm/person and four different heating, ventilation and air conditioning (HVAC system strategies (Variable Air Volume (VAV with reheat and a Fan Coil Unit (FCU, both with and without an energy recovery ventilator. We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities. The same change in ventilation

  6. Free Convection Personalized Ventilation (FCPV)

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Normally we supply fresh air to a room with a diffuser, and this air is distributed in the room according to different principles as: mixing ventilation, displacement ventilation etc. That means we have to supply a very large amount of air to the whole room, although a person in the room totally...

  7. Thermal plumes in ventilated rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    1990-01-01

    The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects. Free...... to be the only possible approach to obtain the volume flow in: thermal plumes in ventilated rooms....

  8. Inhalation therapy in mechanical ventilation

    Science.gov (United States)

    Maccari, Juçara Gasparetto; Teixeira, Cassiano; Gazzana, Marcelo Basso; Savi, Augusto; Dexheimer-Neto, Felippe Leopoldo; Knorst, Marli Maria

    2015-01-01

    Patients with obstructive lung disease often require ventilatory support via invasive or noninvasive mechanical ventilation, depending on the severity of the exacerbation. The use of inhaled bronchodilators can significantly reduce airway resistance, contributing to the improvement of respiratory mechanics and patient-ventilator synchrony. Although various studies have been published on this topic, little is known about the effectiveness of the bronchodilators routinely prescribed for patients on mechanical ventilation or about the deposition of those drugs throughout the lungs. The inhaled bronchodilators most commonly used in ICUs are beta adrenergic agonists and anticholinergics. Various factors might influence the effect of bronchodilators, including ventilation mode, position of the spacer in the circuit, tube size, formulation, drug dose, severity of the disease, and patient-ventilator synchrony. Knowledge of the pharmacological properties of bronchodilators and the appropriate techniques for their administration is fundamental to optimizing the treatment of these patients. PMID:26578139

  9. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D. N.; Nielsen, Peter Vilhelm

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... to ensure that the ventilation system meets the demands it is important to know which parameters that influence the performance of the system. In this work the mixing ventilation principle was investigated. When the mixing ventilation principle is used for the design of a ventilation system it is assumed...

  10. 太阳能猪舍地道通风方式对舍内热环境的影响%Impact of tunnel ventilation on thermal environment in solar heated swine housing

    Institute of Scientific and Technical Information of China (English)

    袁月明; 孙丽丽; 潘世强; 李喜武; 刘海枝; 王春野

    2014-01-01

    In order to control the ground temperature and relative humidity inside pigpens, the solar piggery with tunnel ventilation was adopted in this study. Pigs usually lay down for more than 70% of the time. The environmental control, especially the temperature control at where they lie down (e.g. floor, bed) is crucial in improving the pigs’ performance. This study took the piggery as the research object, using additional solar radiation for the pig beds between the sun and piggery in Changchun. Information on major structures of both the experimental piggery and the control is listed below. The dimensions are 61 m in length, 8.1 m in width, and 3.42 m in height, and the orientation is facing south. The difference between the experimental piggery and the control is that the experimental piggery is mainly divided into two parts, the extra sunspace and itself, which is separated by a common wall. The common wall is a solid wall with a ventilation window and it is covered with an insulating layer during cold seasons. The extra sunspace is arch-shaped, constructed with lightweight steel, and also is covered with an insulating layer during cold seasons. In the experimental piggery, there are 28 units under the pig beds. Each unit 3 500 mm long and 1 970 mm wide and also has its own independent air intake, outlet, and closed airflow tunnel. The positive pressure ventilation axial airflow fan is installed at the air intake in the experimental piggery. The negative pressure ventilation draught fan is fixed at the air outlet. The floor in the control piggery is composed of a cement mortar slope layer, soil compaction, and cement mortar layer. Both experimental barn and control barn housed 275 growing-finishing pigs with mean initial live weight of 28.7±2.2 kg. The pigs were in the growing and fattening stage. With respect to the manner of the tunnel ventilation in the solar piggery, the positive and negative pressure ventilations as well as the fan working at different

  11. Apartment building with controlled ventilation. East Germany: High-efficiency blowers provide fresh air for the heat recovery system of a new apartment building; Miethaus mit kontrollierter Wohnungslueftung. Beim Neubau einer ostdeutschen Wohnanlage erfolgt die Frischluftzufuhr der Waermerueckgewinnungsanlage ueber Hochleistungsluefter

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-11-01

    The Energy Conservation Ordinance contains specifications for energy conservation in the construction of new buildings and the modernisation of old ones. Ventilation is a crucial point. A wholesome room climate and fresh air are important factors in keeping the inhabitants healthy and well. [German] Bei Erstellung von Neubauten und der Sanierung von Altbauten sollten schon heute die Inhalte der aktuell gueltigen Energiesparverordnung beachtet werden. Sie soll bei der Einsparung von Energie sorgen. Doch besonders in Gebaeuden mit guter Waermedaemmung, insbesondere bei Niedrigenergiehaeusern, muss richtig be- und entlueftet werden. Ein wohliges Klima und gute Luft in Wohnraeumen sind wichtig fuer die Gesundheit der Bewohner. (orig.)

  12. Identification of CdnL, a putative transcriptional regulator involved in repair and outgrowth of heat-damaged bacillus cereus spores

    NARCIS (Netherlands)

    Warda, Alicja K.; Tempelaars, Marcel H.; Boekhorst, Jos; Abee, Tjakko; Groot, Masja Nierop N.

    2016-01-01

    Spores are widely present in the environment and are common contaminants in the food chain, creating a challenge for food industry. Nowadays, heat treatments conventionally applied in food processing may become milder to comply with consumer desire for products with higher sensory and nutritional

  13. RedVent. Turned off ventilation at night in schools - risks and opportunities; RedVent. Avstaengd ventilation paa natten i skolor - risker och moejligheter

    Energy Technology Data Exchange (ETDEWEB)

    Haegerhed Engman, Linda; Fyhr, Kristina; Langer, Sarka; Ruud, Svein; Ylmen, Peter

    2011-07-01

    Reduced ventilation rates or shutdown ventilation during nights is often being used in school buildings in order to save energy and can decrease the energy cost for heating and ventilation with at least 30 %. Swedish Building Regulations (BBR) allows reduced ventilation flow in non-residential buildings when no one is using the building but it must not give rise to adverse health effects or damage the building or its installations. Potential risks are mould- and moisture damages and indoor air quality problems. Another question is whether the shut down itself might lead to indoor air quality problems due to chemical reactions between outdoor air and indoor emissions built-up during the night. The study was divided into three steps; an interview with property managers and care-taker, calculations of energy saving potentials and a field study. Measurements were per-formed in one classroom for two weeks in April 2010. Different set-ups for ventilation flow during night time and air tightness of the building envelope were studied; ventilation shut down, intermittent ventilation (15 min every second hour) and continuous full speed ventilation during night. In the studied classroom, shutdown ventilation during nights did not significantly affect the indoor air quality in the classroom during the school day even though there were effects seen during the night. We found a somewhat higher moisture accumulation those nights when the ventilation was shut down and some fractions of particles during intermittent ventilation compared to continues full ventilation during night time. This specific school and classroom were well ventilated and there was no moisture supply from new building material or other types of moisture producing activities. Schools with lower day-time ventilation rates, moisture in building construction, IAQ- or dampness problems as well as buildings close to heavy traffic should analyse the conditions for the specific building before reducing ventilation to

  14. FUNDAMENTALS OF THE THEORY OF VENTILLATION PROCESSES IN THE STEAM TURBINES TPP

    Directory of Open Access Journals (Sweden)

    V. M. Neuimin

    2015-01-01

    Full Text Available  The article proposes the theoretical framework of ventilation processes emerging and going on in the stages of TPP steam turbines during the operating regimes with small-quantity volumetric flow rates in the low-pressure cylinder. The basic theory includes new physicomathematical models for estimating the ventilating capacity losses and ventilation heatings-up of the steam and the air-gas channel of the turbine; search and investigation of the factors causing the increased momental loads on the blade wheels of the finale stages which are likely to lead to destruction of the rotating blades. The paper renders the practical results of utilizing the theoretical framework of ventilation processes.The author obtains a new mathematical relation for high-accuracy assessment of the ventilating capacity losses accounting for all the diversification of parameters defining the level of these losses (it is established that the Coriolis force contributes twice as much to the ventilating capacity losses as the centrifugal force. Seven ordinary formulae obtained on its basis provide a separate stage ventilation-losses immediate evaluation (with rotation blades of the finale stage not unwinding from the turning, with rotation blades of the finale and intermediate stages unwinding from the turning, in the turbine altogether-vapor-evacuated including by readings of the regular instruments located at the connecters of the exhaust part of the lowpressure cylinder.As the cornerstone of the new ventilation heating-up evaluation system the author lays two experimentally established facts: the ventilating capacity losses are practically constant at working steam negligible volumetric flow rates; symmetrical ventilating flows in the blade channel mingle entirely to the moment of their split up at the periphery. This renders possible estimating the complete enthalpy increment of the steam being discharged from a stage in relation to the enthalpy of the steam being

  15. Ventilation and respiratory mechanics.

    Science.gov (United States)

    Sheel, Andrew William; Romer, Lee M

    2012-04-01

    During dynamic exercise, the healthy pulmonary system faces several major challenges, including decreases in mixed venous oxygen content and increases in mixed venous carbon dioxide. As such, the ventilatory demand is increased, while the rising cardiac output means that blood will have considerably less time in the pulmonary capillaries to accomplish gas exchange. Blood gas homeostasis must be accomplished by precise regulation of alveolar ventilation via medullary neural networks and sensory reflex mechanisms. It is equally important that cardiovascular and pulmonary system responses to exercise be precisely matched to the increase in metabolic requirements, and that the substantial gas transport needs of both respiratory and locomotor muscles be considered. Our article addresses each of these topics with emphasis on the healthy, young adult exercising in normoxia. We review recent evidence concerning how exercise hyperpnea influences sympathetic vasoconstrictor outflow and the effect this might have on the ability to perform muscular work. We also review sex-based differences in lung mechanics.

  16. Estimation of Lung Ventilation

    Science.gov (United States)

    Ding, Kai; Cao, Kunlin; Du, Kaifang; Amelon, Ryan; Christensen, Gary E.; Raghavan, Madhavan; Reinhardt, Joseph M.

    Since the primary function of the lung is gas exchange, ventilation can be interpreted as an index of lung function in addition to perfusion. Injury and disease processes can alter lung function on a global and/or a local level. MDCT can be used to acquire multiple static breath-hold CT images of the lung taken at different lung volumes, or with proper respiratory control, 4DCT images of the lung reconstructed at different respiratory phases. Image registration can be applied to this data to estimate a deformation field that transforms the lung from one volume configuration to the other. This deformation field can be analyzed to estimate local lung tissue expansion, calculate voxel-by-voxel intensity change, and make biomechanical measurements. The physiologic significance of the registration-based measures of respiratory function can be established by comparing to more conventional measurements, such as nuclear medicine or contrast wash-in/wash-out studies with CT or MR. An important emerging application of these methods is the detection of pulmonary function change in subjects undergoing radiation therapy (RT) for lung cancer. During RT, treatment is commonly limited to sub-therapeutic doses due to unintended toxicity to normal lung tissue. Measurement of pulmonary function may be useful as a planning tool during RT planning, may be useful for tracking the progression of toxicity to nearby normal tissue during RT, and can be used to evaluate the effectiveness of a treatment post-therapy. This chapter reviews the basic measures to estimate regional ventilation from image registration of CT images, the comparison of them to the existing golden standard and the application in radiation therapy.

  17. Metabolism, temperature, and ventilation.

    Science.gov (United States)

    Mortola, Jacopo P; Maskrey, Michael

    2011-10-01

    In mammals and birds, all oxygen used (VO2) must pass through the lungs; hence, some degree of coupling between VO2 and pulmonary ventilation (VE) is highly predictable. Nevertheless, VE is also involved with CO2 elimination, a task that is often in conflict with the convection of O2. In hot or cold conditions, the relationship between VE and VO2 includes the participation of the respiratory apparatus to the control of body temperature and water balance. Some compromise among these tasks is achieved through changes in breathing pattern, uncoupling changes in alveolar ventilation from VE. This article examines primarily the relationship between VE and VO2 under thermal stimuli. In the process, it considers how the relationship is influenced by hypoxia, hypercapnia or changes in metabolic level. The shuffling of tasks in emergency situations illustrates that the constraints on VE-VO2 for the protection of blood gases have ample room for flexibility. However, when other priorities do not interfere with the primary goal of gas exchange, VE follows metabolic rate quite closely. The fact that arterial CO2 remains stable when metabolism is changed by the most diverse circumstances (moderate exercise, cold, cold and exercise combined, variations in body size, caloric intake, age, time of the day, hormones, drugs, etc.) makes it unlikely that VE and metabolism are controlled in parallel by the condition responsible for the metabolic change. Rather, some observations support the view that the gaseous component of metabolic rate, probably CO2, may provide the link between the metabolic level and VE.

  18. Expression and significance of heat shock protein 70 and nuclear factor-κB in ventilator-induced lung injury in rats%大鼠呼吸机相关肺损伤热休克蛋白70和核因子-κB的表达及其意义

    Institute of Scientific and Technical Information of China (English)

    付笑飞; 刘东雷; 王建军

    2010-01-01

    目的 探讨呼吸机所致肺损伤(VILI)炎症反应中热休克蛋白70(HSP70)和核因子-κB(NF-κB)表达的意义.方法 健康SD大鼠30只,实施麻醉和气管切开术后分别接受不同潮气量(VT)的通气(通气时间均为4 h).随机分为以下3组:对照组(A组);常规通气组(B组,VT=10ml/kg);损伤通气组(C组,VT=40ml/kg).4 h后放血处死动物,测定肺湿/干比重、髓过氧化物酶(MPO)活性及肺泡灌洗液(BALF)中总蛋白含量,光镜下行白细胞(WBC)计数;Western blot检测肺组织HSP70及NF-κB的表达.结果 在大潮气量机械通气4 h后,BALF中总蛋白含量、肺湿干比、WBC计数和MPO水平(3.89±0.31、5.83±0.42、6.10±0.80、7.31±1.21)均明显更高(P<0.05);肺组织中HSP70、NF-κB表达水平(1.36±0.13、0.41±0.07)均显著增加,且两者呈负相关.结论 HSP70可通过抑制NF-κB的活性,保护肺组织避免VILI.%Objective To investigate the expression and significance of heat shock protein 70 (HSP70) and nuclear factor-κB (NF-κB) in a rat model of ventilator-induced lung injury (VILI). Methods Thirty healthy SD rats were randomly divided into three groups (each 10 rats): control group (group A, no ventilation), conventional ventilation group (group B, VT = 10 ml/kg), lung injury group (group C, VT =40 ml/kg). After anesthesia and tracheotomy were performed, rats received ventilation with different volumes for 4 h. The rats were killed by exsanguinations. The lung wet/dry weight, myeloperoxidase (MPO) activity and total protein level and counts of white blood cells (WBC) in broncho-alveolar lavage fluid (BALF) were tested. The expression of HSP70 and NF-κB was detected by using Western blotting.Results After injurious ventilation for 4 h, the level of lung wet/dry weight, MPO activity and total protein level and counts of WBC were 5.83 ± 0.42, 7.31 ± 1.21, 3.89 ± 0.31, 6. 10 ± 0. 80, respectively.The average values of HSP70 and NF-κB proteins were 1.36 ±0.13, and 0. 41 ±0

  19. Home ventilation systems in Austria. Practical experience and demand of research; Wohnraumlueftungsanlagen in Oesterreich. Praxiserfahrungen und Forschungsbedarf

    Energy Technology Data Exchange (ETDEWEB)

    Leitzinger, W. [GFD Erneuerbare Energie, Wien (Austria); Greml, A. [FHS-Kufstein (Austria); Bluemel, E. [AEE INTEC, Gleisdorf (Austria); Kapferer, R. [Energie Tirol, Innsbruck (Austria)

    2005-02-01

    Home ventilation including heat recovery is presently not yet a standard equipment of residential buildings. According to this there is still a big doubt in terms of the system quality. This affects negative to the dispersion of ventilation systems. The fundamental intention of this project was the objective demonstration of positive solutions, faults and defects to improve the quality of home ventilation systems in the future. (orig.)

  20. Optimized Design of Outlets Layout in Thermal Pressure Naturally Ventilated Rooms

    Directory of Open Access Journals (Sweden)

    Xuemin Sui

    2013-05-01

    Full Text Available Using thermal pressure ventilation principles to achieve passive ventilation in buildings is an important way to promote green and low consumption building strategy. The reasonable vents layout design can fully tap the potential of thermal pressure ventilation. Aimed to civil buildings with internal heating source, using Computational Fluid Dynamics (CFD technology, the effects of outlets layout on thermal natural ventilation in rooms were studied. Three types of typical air outlets distribution patterns were considered and the airflow distribution of thermal natural ventilation in rooms was simulated. The ventilation rates and the average workspace temperatures of different simulated conditions were given. The velocity and temperature fields of different simulated conditions were analyzed and the indoor thermal stratification characteristics were discussed. In addition, the effective heat coefficients of different simulated conditions were analyzed and compared. The results show that the strategy of dispersed outlets on ceiling can achieve the optimal natural ventilation effect. The results can provide theoretical references for the design of natural ventilation system in civil buildings.

  1. Investigation of Indoor Climate in a Naturally Ventilated Office Building

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Kalyanova, Olena; Jensen, Rasmus Lund;

    2008-01-01

    A measuring program in a naturally ventilated office building in Copenhagen was carried out to document the indoor climate and ventilation system performance during a year. It included a questionnaire regarding the perceived indoor environmental quality and physical measurements of thermal comfort...... to a combination of poor control of solar shading and a very high local heat load that was above the Danish recommendations for naturally ventilated office buildings. Both measured and perceived indoor air quality in the building was in general very high. The measured air flow rates was relatively high due...... to the need for cooling in the office building, while the level of infiltration was quite low indicating an airtight construction....

  2. Humidification during mechanical ventilation in the adult patient.

    Science.gov (United States)

    Al Ashry, Haitham S; Modrykamien, Ariel M

    2014-01-01

    Humidification of inhaled gases has been standard of care in mechanical ventilation for a long period of time. More than a century ago, a variety of reports described important airway damage by applying dry gases during artificial ventilation. Consequently, respiratory care providers have been utilizing external humidifiers to compensate for the lack of natural humidification mechanisms when the upper airway is bypassed. Particularly, active and passive humidification devices have rapidly evolved. Sophisticated systems composed of reservoirs, wires, heating devices, and other elements have become part of our usual armamentarium in the intensive care unit. Therefore, basic knowledge of the mechanisms of action of each of these devices, as well as their advantages and disadvantages, becomes a necessity for the respiratory care and intensive care practitioner. In this paper, we review current methods of airway humidification during invasive mechanical ventilation of adult patients. We describe a variety of devices and describe the eventual applications according to specific clinical conditions.

  3. Humidification during Mechanical Ventilation in the Adult Patient

    Directory of Open Access Journals (Sweden)

    Haitham S. Al Ashry

    2014-01-01

    Full Text Available Humidification of inhaled gases has been standard of care in mechanical ventilation for a long period of time. More than a century ago, a variety of reports described important airway damage by applying dry gases during artificial ventilation. Consequently, respiratory care providers have been utilizing external humidifiers to compensate for the lack of natural humidification mechanisms when the upper airway is bypassed. Particularly, active and passive humidification devices have rapidly evolved. Sophisticated systems composed of reservoirs, wires, heating devices, and other elements have become part of our usual armamentarium in the intensive care unit. Therefore, basic knowledge of the mechanisms of action of each of these devices, as well as their advantages and disadvantages, becomes a necessity for the respiratory care and intensive care practitioner. In this paper, we review current methods of airway humidification during invasive mechanical ventilation of adult patients. We describe a variety of devices and describe the eventual applications according to specific clinical conditions.

  4. Evaluation Tool of Climate Potential for Ventilative Cooling

    DEFF Research Database (Denmark)

    Belleri, Annamaria; Psomas, Theofanis Ch.; Heiselberg, Per Kvols

    2015-01-01

    designers with useful information about the level of ventilation rates needed to offset given rates of internal heat gain. The paper also presents several analysis performed on a reference room in a case study (Aarhus town hall office in Denmark) in order to validate the analysis method development......The new initiatives and regulations towards nearly zero energy buildings forces designers to exploit the cooling potential of the climate to reduce the overheating occurrence and to improve thermal comfort indoors. Climate analysis is particularly useful at early design stages to support decision....... Within IEA Annex 62 project, national experts are working on the development of a climate evaluation tool, which aims at assessing the potential of ventilative cooling by taking into account also building envelope thermal properties, internal gains and ventilation needs. The analysis is based on a single...

  5. Repairing Hidden Cracks in Coolant Tubes

    Science.gov (United States)

    Mills, R. C., Sr.; Duesberg, J.

    1984-01-01

    Repair technique closes leaks in tubes or conduits where access limited to wall opposite crack. Technique applicable to any tubular assembly where tubes bundled together or bonded to supporting shell, such as in heat exchangers. Procedure provides structural support to area failed and uninterrupted flow without significantly altering heat-transfer profile.

  6. Mechanical ventilation of the premature neonate.

    Science.gov (United States)

    Brown, Melissa K; DiBlasi, Robert M

    2011-09-01

    Although the trend in the neonatal intensive care unit is to use noninvasive ventilation whenever possible, invasive ventilation is still often necessary for supporting pre-term neonates with lung disease. Many different ventilation modes and ventilation strategies are available to assist with the optimization of mechanical ventilation and prevention of ventilator-induced lung injury. Patient-triggered ventilation is favored over machine-triggered forms of invasive ventilation for improving gas exchange and patient-ventilator interaction. However, no studies have shown that patient-triggered ventilation improves mortality or morbidity in premature neonates. A promising new form of patient-triggered ventilation, neurally adjusted ventilatory assist (NAVA), was recently FDA approved for invasive and noninvasive ventilation. Clinical trials are underway to evaluate outcomes in neonates who receive NAVA. New evidence suggests that volume-targeted ventilation modes (ie, volume control or pressure control with adaptive targeting) may provide better lung protection than traditional pressure control modes. Several volume-targeted modes that provide accurate tidal volume delivery in the face of a large endotracheal tube leak were recently introduced to the clinical setting. There is ongoing debate about whether neonates should be managed invasively with high-frequency ventilation or conventional ventilation at birth. The majority of clinical trials performed to date have compared high-frequency ventilation to pressure control modes. Future trials with premature neonates should compare high-frequency ventilation to conventional ventilation with volume-targeted modes. Over the last decade many new promising approaches to lung-protective ventilation have evolved. The key to protecting the neonatal lung during mechanical ventilation is optimizing lung volume and limiting excessive lung expansion, by applying appropriate PEEP and using shorter inspiratory time, smaller tidal

  7. Climate control of natural ventilated pig houses

    NARCIS (Netherlands)

    Bontsema, J.; Straten, van G.; Salomons, L.; Klooster, van 't C.E.

    1996-01-01

    Ventilation in pig houses is important for maintaining a good climate for the welfare of animals and humans and for an optimal production. Mechanical ventilation has a good performance, since the ventilation rate can easily be controlled, but it is energy demanding, whereas natural ventilation is ch

  8. 30 CFR 57.8520 - Ventilation plan.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Ventilation plan. 57.8520 Section 57.8520... Underground Only § 57.8520 Ventilation plan. A plan of the mine ventilation system shall be set out by the... ventilation plan or revisions thereto shall be submitted to the District Manager for review and comments...

  9. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D.N.; Nielsen, Peter V.

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order to e...

  10. Ventilation rates in recently constructed U.S. school classrooms.

    Science.gov (United States)

    Batterman, S; Su, F-C; Wald, A; Watkins, F; Godwin, C; Thun, G

    2017-09-01

    Low ventilation rates (VRs) in schools have been associated with absenteeism, poorer academic performance, and teacher dissatisfaction. We measured VRs in 37 recently constructed or renovated and mechanically ventilated U.S. schools, including LEED and EnergyStar-certified buildings, using CO2 and the steady-state, build-up, decay, and transient mass balance methods. The transient mass balance method better matched conditions (specifically, changes in occupancy) and minimized biases seen in the other methods. During the school day, air change rates (ACRs) averaged 2.0±1.3 hour(-1) , and only 22% of classrooms met recommended minimum ventilation rates. HVAC systems were shut off at the school day close, and ACRs dropped to 0.21±0.19 hour(-1) . VRs did not differ by building type, although cost-cutting and comfort measures resulted in low VRs and potentially impaired IAQ. VRs were lower in schools that used unit ventilators or radiant heating, in smaller schools and in larger classrooms. The steady-state, build-up, and decay methods had significant limitations and biases, showing the need to confirm that these methods are appropriate. Findings highlight the need to increase VRs and to ensure that energy saving and comfort measures do not compromise ventilation and IAQ. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air......This study presents a novel method for advanced ventilation of hospital wards leading to improved air quality at reduced ventilation rate. The idea is to evacuate the bio-effluents generated from patients’ body by local exhaustion before being spread in the room. This concept was realized by using...... conditioned via mixing total volume ventilation system supplying air through a ceiling mounted diffuser. All experiments were performed at room air temperature of 23ºC. A thermal manikin was used to simulate a polluting patient on the bed equipped with the ventilated mattress. Two heated dummies were used...

  12. 46 CFR 111.103-1 - Power ventilation systems except machinery space ventilation systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power ventilation systems except machinery space ventilation systems. 111.103-1 Section 111.103-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Power ventilation systems except machinery space ventilation systems. Each power ventilation system...

  13. 热休克蛋白抑制剂格尔德霉素衍生物在机械通气肺损伤中的作用研究%Study of the role of heat shock protein 90 inhibitor 17-dimethylaminoethylamino-17-demethoxygeldanamycin in mechanical ventilation-induced lung injury

    Institute of Scientific and Technical Information of China (English)

    董文文; 江来

    2014-01-01

    Objective To investigate the effects and mechanisms of the heat shock protein (HSP) 90 inhibitor 17-dimethylaminoethylamino-17-demethoxygeldanamycin (17-DMAG) on mechanical ventilation-induced lung injury.Methods Twenty-eight Male ICR mice(7-9 weeks old) were randomly divided into four groups by random number table method(n=7):control group (CON group),mechanical ventilation group(VEN group),17-DMAG group and 17-DMAG + Mechanical ventilation group(17-DMAG+VEN group).The protein concentration and cell counts of bronchoalveolar lavage fluid were detected after four hours of ventilation.The wet-to-dry weight ratio (W/D) and pathological changes of lung tissue were examined.Interleukin (IL)-1 β,tumor necrosis factor-α (TNF-α) and high mobility group box 1 (HMGB1) levels in lung tissue homogenates were measured by enzymelinked immunosorbent assay (ELISA).Results Protein concentration and cell count from bronchoalveolar lavage fluid in VEN group were (0.29±0.05) g/L and (2.84±0.55)/ml,significantly higher(P<0.01) than those in both CON groups and 17-DMAG+VEN group (P<0.01).Lung tissue W/D in VEN group was (5.14±0.19) much higher than that in both control group (4.65±0.15) and 17-DMAG +VEN group (4.79±0.14) (P<0.01).Pre-treatment with 17-DMAG could significantly reduce the ventilation-induced lung tissue damage.Four hours of mechanical ventilation could induce IL-1β,TNF-α and HMGB1 protein expression in lung tissue.Pretreatment with 17-DMAG could significantly reduce the mechanical ventilation-induced HMGB1 expression:there was statistical difference between 17-DMAG+VEN group (15.4±3.0) mg/g and VEN group (18.9±2.5) mg/g in HMGB1 (P<0.05).Conclusions Our results indicate that 17-DMAG can reduce pulmonary edema and exert protective effects in mechanical ventilation-induced lung injury by inhibiting the protein expression of HMGB1.%目的 探讨热休克蛋白(heat shock protein,HSP) 90抑制剂格尔德霉素衍生物(17-dimethylaminoethylamino-17

  14. Eye muscle repair - discharge

    Science.gov (United States)

    ... Lazy eye repair - discharge; Strabismus repair - discharge; Extraocular muscle surgery - discharge ... You or your child had eye muscle repair surgery to correct eye muscle ... term for crossed eyes is strabismus. Children most often ...

  15. Ventral hernia repair

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007661.htm Ventral hernia repair To use the sharing features on this page, please enable JavaScript. Ventral hernia repair is surgery to repair a ventral hernia. ...

  16. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  17. Mechanical ventilation in rural ICUs.

    Science.gov (United States)

    Fieselmann; Bock; Hendryx; Wakefield; Helms; Bentler

    1999-01-01

    BACKGROUND: In recent years, rural hospitals have expanded their scope of specialized services, which has led to the development and staffing of rural intensive care units (ICUs). There is little information about the breadth, quality or outcomes of these services. This is particularly true for specialized ICU services such as mechanical ventilation, where little, if any, information exists specifically for rural hospitals. The long-term objectives of this project were to evaluate the quality of medical care provided to mechanically ventilated patients in rural ICUs and to improve patient care through an educational intervention. This paper reports baseline data on patient and hospital characteristics for both rural and rural referral hospitals. RESULTS: Twenty Iowa hospitals were evaluated. Data collected on 224 patients demonstrated a mean age of 70 years and a mean ICU admission Acute Physiology and Chronic Health Evaluation (APACHE) II score of 22, with an associated 36% mortality. Mean length of ICU stay was 10 days, with 7.7 ventilated days. Significant differences were found in both institutional and patient variables between rural referral hospitals and rural hospitals with more limited resources. A subgroup of patients with diagnoses associated with complex ventilation had higher mortality rates than patients without these conditions. Patients who developed nosocomial events had longer mean ventilator and ICU days than patients without nosocomial events. This study also found ICU practices that frequently fell outside the guidelines recommended by a task force describing minimum standards of care for critically ill patients with acute respiratory failure on mechanical ventilation. CONCLUSIONS: Despite distinct differences in the available resources between rural referral and rural hospitals, overall mortality rates of ventilated patients are similar. Considering the higher mortality rates observed in patients with complicated medical conditions requiring

  18. Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Tomasi, Roberta

    and by thermal manikin equivalent temperatures. Contaminant removal effectiveness and air change efficiency were used to characterize the ventilation effectiveness. The vertical air temperature differences that occurred when floor cooling was combined with cold conditioned air supply were well within the limits...... for comfortable thermal environment recommended by the standards. The cooler supply air mixed well and the effect of the position of air terminal devices was small. When warm unconditioned outside air was supplied by mixing ventilation in combination with the radiant floor cooling, low floor temperature......Mixing air ventilation system is one of the main ventilation concepts applied in residential buildings. The effect of combining the mixing ventilation system with the radiant floor heating has been well established, whereas the validation of using the floor for cooling in summer is still...

  19. Ventilation equations for improved exothermic process control.

    Science.gov (United States)

    McKernan, John L; Ellenbecker, Michael J

    2007-04-01

    Exothermic or heated processes create potentially unsafe work environments for an estimated 5-10 million American workers each year. Excessive heat and process contaminants have the potential to cause acute health effects such as heat stroke, and chronic effects such as manganism in welders. Although millions of workers are exposed to exothermic processes, insufficient attention has been given to continuously improving engineering technologies for these processes to provide effective and efficient control. Currently there is no specific occupational standard established by OSHA regarding exposure to heat from exothermic processes, therefore it is important to investigate techniques that can mitigate known and potential adverse occupational health effects. The current understanding of engineering controls for exothermic processes is primarily based on a book chapter written by W. C. L. Hemeon in 1955. Improvements in heat transfer and meteorological theory necessary to design improved process controls have occurred since this time. The research presented involved a review of the physical properties, heat transfer and meteorological theories governing buoyant air flow created by exothermic processes. These properties and theories were used to identify parameters and develop equations required for the determination of buoyant volumetric flow to assist in improving ventilation controls. Goals of this research were to develop and describe a new (i.e. proposed) flow equation, and compare it to currently accepted ones by Hemeon and the American Conference of Governmental Industrial Hygienists (ACGIH). Numerical assessments were conducted to compare solutions from the proposed equations for plume area, mean velocity and flow to those from the ACGIH and Hemeon. Parameters were varied for the dependent variables and solutions from the proposed, ACGIH, and Hemeon equations for plume area, mean velocity and flow were analyzed using a randomized complete block statistical

  20. Determinants of ventilation behavior in naturally ventilated dwellings: Identification and quantification of relationships

    NARCIS (Netherlands)

    Levie, D.; Kluizenaar, Y. de; Hoes-van Oeffelen, E.C.M.; Hofstetter, H.; Janssen, S.A.; Spiekman, M.E.; Koene, F.G.H.

    2014-01-01

    Background: Ventilation in dwellings is essential for well-being and health. However, insight in determinants of ventilation behavior is still limited. Aim: Identifying determinants of ventilation behavior and quantifying relationships. Secondly, identifying households characteristics associated wit

  1. Enhancement of natural ventilation in rectangular enclosure with two openings by thin fin

    Institute of Scientific and Technical Information of China (English)

    YANG Yi; DENG Qi-hong

    2005-01-01

    A numerical method was used to study the natural ventilation in a rectangular enclosure with two symmetrical openings. In order to improve the natural ventilation efficiency, a fin was introduced into the enclosure.Steady-state heat transfer by laminar natural ventilation in a partially divided rectangular enclosure was investigated by numerically solving equations of mass, momentum and energy. Streamlines and isotherms were produced and heat transfer rate were calculated. A parametric study was carried out using the following parameters: Rayleigh number (1 × 103 - 1 × 106) , dimensionless length (0 - 0.7) and position values (-0. 7 - 0. 7). It is found that the Nusselt number is an increasing function of Rayleigh number. By comparing with no-fin case, it is concluded that fin can effectively enhance the natural ventilation in the enclosure.

  2. Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Destaillats, H.; Apte, M.G.; Destaillats,, Hugo; Fisk, Michael G. Apte and William J.

    2008-10-01

    Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

  3. Summer Thermal Performance of Ventilated Roofs with Tiled Coverings

    Science.gov (United States)

    Bortoloni, M.; Bottarelli, M.; Piva, S.

    2017-01-01

    The thermal performance of a ventilated pitched roof with tiled coverings is analysed and compared with unventilated roofs. The analysis is carried out by means of a finite element numerical code, by solving both the fluid and thermal problems in steady-state. A whole one-floor building with a pitched roof is schematized as a 2D computational domain including the air-permeability of tiled covering. Realistic data sets for wind, temperature and solar radiation are used to simulate summer conditions at different times of the day. The results demonstrate that the batten space in pitched roofs is an effective solution for reducing the solar heat gain in summer and thus for achieving better indoor comfort conditions. The efficiency of the ventilation is strictly linked to the external wind conditions and to buoyancy forces occurring due to the heating of the tiles.

  4. Influence of Persons' Movements on Ventilation Effectiveness

    DEFF Research Database (Denmark)

    Brohus, Henrik; Hyldig, Mikkel; Kamper, Simon

    2008-01-01

    of different kinds of movement compared with the case of no movements. It is found that mixing ventilation is considerably more robust compared with displacement ventilation. At the same time it is found that displacement ventilation on average is more effective than mixing ventilation when movements prevail......Most often the ventilation effectiveness of a ventilated room is determined without considering the influence of persons´ movements. Even though the main reason for supplying the ventilation may be to create a healthy and productive environment for the occupants, their own influence...... on the ventilation is usually disregarded. This paper presents results from a systematic investigation of the movements´ influence on the ventilation effectiveness using human subjects combined with tracer gas measurements. Several typical "movements" are defined and carefully repeated to determine the influence...

  5. Assessment of the potential of roof turbine ventilators for bathroom ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Ishiow Kuo [National United Univ., Dept. of Architecture, Miao-li City (Taiwan); Chiming Lai [Leader Univ., Dept. of Construction Technology, Tainan City (Taiwan)

    2005-06-15

    This study set out to investigate the potential of installing a new common roof turbine ventilator on to an existing bathroom ventilation system which serves 14 bathrooms in the first dormitory block of Leader University in Taiwan, and evaluate the overall ventilation performance of this new combination. Field measurements of airflow in the ventilation ducts and low-speed wind tunnel experiments for this turbine ventilator were carried out. The results showed that the combination of the roof turbine ventilator and bathroom ventilation were successful in achieving sufficient air change rate in bathrooms, and this ventilation design alternative is now proposed as a method of improving the indoor air environment in bathrooms. (Author)

  6. Conjugate heat and mass transfer in heat mass exchanger ducts

    CERN Document Server

    Zhang, Li-Zhi

    2013-01-01

    Conjugate Heat and Mass Transfer in Heat Mass Exchanger Ducts bridges the gap between fundamentals and recent discoveries, making it a valuable tool for anyone looking to expand their knowledge of heat exchangers. The first book on the market to cover conjugate heat and mass transfer in heat exchangers, author Li-Zhi Zhang goes beyond the basics to cover recent advancements in equipment for energy use and environmental control (such as heat and moisture recovery ventilators, hollow fiber membrane modules for humidification/dehumidification, membrane modules for air purification, desi

  7. TECHNICAL BASIS FOR VENTILATION REQUIREMENTS IN TANK FARMS OPERATING SPECIFICATIONS DOCUMENTS

    Energy Technology Data Exchange (ETDEWEB)

    BERGLIN, E J

    2003-06-23

    This report provides the technical basis for high efficiency particulate air filter (HEPA) for Hanford tank farm ventilation systems (sometimes known as heating, ventilation and air conditioning [HVAC]) to support limits defined in Process Engineering Operating Specification Documents (OSDs). This technical basis included a review of older technical basis and provides clarifications, as necessary, to technical basis limit revisions or justification. This document provides an updated technical basis for tank farm ventilation systems related to Operation Specification Documents (OSDs) for double-shell tanks (DSTs), single-shell tanks (SSTs), double-contained receiver tanks (DCRTs), catch tanks, and various other miscellaneous facilities.

  8. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance......Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...

  9. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  10. The air quality in ventilation installations. Practical guidelines; Qualite de l'air dans les installations aerauliques. Guide pratique

    Energy Technology Data Exchange (ETDEWEB)

    Angeli, L. [France Air, 91 - Chilly Mazarin (France); Bianchina, M. [Unelvent, 93 - Le Bourget (France); Blazy, M. [Anjos, 01 - Torcieu (France); Boulanger, X. [Aldes, 21 - Chenove (France); Chiesa, M. [Atlantic (France); Duclos, M. [Groupe Titanair, 69 - Lyon (France); Hubert, D.; Kridorian, O. [Groupe Astato, Blanc Mesnil (France); Josserand, O. [Carrier (Belgium); Lancieux, C. [Camfil, 60 - Saint Martin Longueau (France); Lemaire, J.C. [Agence de l' Environnement et de la Maitrise de l' Energie, ADEME, 75 - Paris (France); Petit, Ph. [Compagnie Industrielle d' Applications Thermiques ( CIAT ), 75 - Paris (France); Ribot, B. [Electricite de France (EDF), 75 - Paris (France); Tokarek, S. [Gaz de France (GDF), 75 - Paris (France); Bernard, A.M.; Tissot, A. [Centre Technique des Industries Aerauliques et Thermiques (CETIAT), 69 - Villeurbanne (France)

    2004-07-01

    The present guide aims to provide design departments, maintenance companies and builders with practical guidelines and recommendations for the installation of ventilation and air-conditioning systems. The objective is to ensure good Indoor Air Quality (IAQ) and to safeguard the health and well-being of the occupants. The guide deals with aspects of design, dimensioning, installation and servicing, all of which play a major role in guaranteeing IAQ and duct-work hygiene. These steps are reviewed for the principal ventilation systems met in both residential and commercial premises. The first part presents the system and draws the attention of the user to specific points which require particular care in term of IAQ. The second part details recommended practice component by component, in respect of design, installation and servicing. Application of these simple guidelines during the various project stages is essential, in order to ensure a good IAQ in ventilation systems. Content: introduction; good ventilation; systems: exhaust ventilation, balanced ventilation, air handling unit, terminal ventilation units, impact of systems on indoor air quality, components: air inlet, air filter, heat recovery unit, heating or cooling coil, humidifier, mechanical fan unit, cowl and hybrid ventilation fan, mixing box, ventilation duct-work, air outlet and air terminal device; references.

  11. Chilled ceiling and displacement ventilation system: Laboratory study with high cooling load

    OpenAIRE

    Schiavon, S.; Bauman, FS; Tully, B; Rimmer, J

    2015-01-01

    © 2015 ASHRAE.Radiant chilled ceilings with displacement ventilation represent a promising system that combines the energy efficiency of both subsystems with the opportunity for improved ventilation performance. Laboratory experiments were conducted for an interior zone office with a very high cooling load (91.0 W/m2) and with two different heat source heights to investigate their influence on thermal stratification and air change effectiveness. The results showed that displacement ventilatio...

  12. Centrifugal Blower for Personal Air Ventilation System (PAVS) - Phase 1

    Science.gov (United States)

    2015-02-01

    functionality. 15. SUBJECT TERMS COOLING SBIR REPORTS AXIAL FLOW FANS OFF THE SHELF EQUIPMENT BLOWERS LIGHTWEIGHT CENTRIFUGAL FORCE...HEAT STRESS (PHYSIOLOGY) AIR FLOW VENTILATION PORTABLE EQUIPMENT PERSONAL COOLING SYSTEMS EFFICIENCY EVAPORATION INTEGRATED SYSTEMS PROTOTYPES...gH Vn ad s ad s 4 1 4 3     is angular speed (2rpm) V is volumetric flow rate Had is the fan pumping head (in meters) g is the

  13. Contaminant Distribution Around Persons in Rooms Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.

    An optimal design of the ventilation system needs a proper prediction of the velocity, temperature and contaminant distribution in the room. Traditionally this is done either by the use of simplified models or by a somewhat more comprehensive CFD-simulation. Common to both methods is usually the ...... the lack of consideration for the persons present in the room. This paper deals with some of the effects of persons present in a displacement ventilated room, especially the effect on the contaminant distribution.......An optimal design of the ventilation system needs a proper prediction of the velocity, temperature and contaminant distribution in the room. Traditionally this is done either by the use of simplified models or by a somewhat more comprehensive CFD-simulation. Common to both methods is usually...

  14. Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Logue, Jennifer; Singer, Brett

    2010-06-01

    The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

  15. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  16. The ventilation and climate modelling of rapid development tunnel drivages

    Energy Technology Data Exchange (ETDEWEB)

    Lowndes, I.S.; Crossley, A.J.; Yang, Z.Y. [University of Nottingham, Nottingham (United Kingdom). School of Chemical Environmental & Mining Engineering

    2004-03-01

    The extraction of minerals and coal at greater depth, employing higher-powered machinery to increase production levels, has imposed an increased burden on ventilation systems to maintain an acceptable working environment. There may be an economic or practical limit to the climatic improvement that may be obtained by the sole use of ventilation air. Where this limit is identified, there may be the need to consider the selective application of air-cooling systems. This paper details the construction of a computer based climatic prediction tool developed at the University of Nottingham. The current model predicts the psychrometric and thermodynamic conditions within long rapid development single entry tunnel drivages. The model takes into account the mass and heat transfer between the strata, water, machinery and the ventilation air. The results produced by the model have been correlated against ventilation, climatic and operational data, obtained from a number of rapid tunnel developments within UK deep coalmines. The paper details the results of a series of correlation and validation studies conducted against the ventilation and climate survey data measured within 105s district Tail Gate tunnel development at Maltby Colliery, UK. The paper concludes by presenting the results of a case study that illustrate the application of the validated model to the design and operation of an integrated mine ventilation and cooling system. The case study illustrates the effect that an increased depth and hence increased virgin strata temperature has on the climate experienced within rapid tunnel developments. Further investigations were performed to identify the optimum cooling strategy that should be adopted to maintain a satisfactory climate at the head of the drivage.

  17. Enhanced deep ocean ventilation and oxygenation with global warming

    Science.gov (United States)

    Froelicher, T. L.; Jaccard, S.; Dunne, J. P.; Paynter, D.; Gruber, N.

    2014-12-01

    Twenty-first century coupled climate model simulations, observations from the recent past, and theoretical arguments suggest a consistent trend towards warmer ocean temperatures and fresher polar surface oceans in response to increased radiative forcing resulting in increased upper ocean stratification and reduced ventilation and oxygenation of the deep ocean. Paleo-proxy records of the warming at the end of the last ice age, however, suggests a different outcome, namely a better ventilated and oxygenated deep ocean with global warming. Here we use a four thousand year global warming simulation from a comprehensive Earth System Model (GFDL ESM2M) to show that this conundrum is a consequence of different rates of warming and that the deep ocean is actually better ventilated and oxygenated in a future warmer equilibrated climate consistent with paleo-proxy records. The enhanced deep ocean ventilation in the Southern Ocean occurs in spite of increased positive surface buoyancy fluxes and a constancy of the Southern Hemisphere westerly winds - circumstances that would otherwise be expected to lead to a reduction in deep ocean ventilation. This ventilation recovery occurs through a global scale interaction of the Atlantic Meridional Overturning Circulation undergoing a multi-centennial recovery after an initial century of transient decrease and transports salinity-rich waters inform the subtropical surface ocean to the Southern Ocean interior on multi-century timescales. The subsequent upwelling of salinity-rich waters in the Southern Ocean strips away the freshwater cap that maintains vertical stability and increases open ocean convection and the formation of Antarctic Bottom Waters. As a result, the global ocean oxygen content and the nutrient supply from the deep ocean to the surface are higher in a warmer ocean. The implications for past and future changes in ocean heat and carbon storage will be discussed.

  18. Air Distribution in a Furnished Room Ventilated by Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, June Richter; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations of the furnit......Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations...

  19. Termite mounds harness diurnal temperature oscillations for ventilation.

    Science.gov (United States)

    King, Hunter; Ocko, Samuel; Mahadevan, L

    2015-09-15

    Many species of millimetric fungus-harvesting termites collectively build uninhabited, massive mound structures enclosing a network of broad tunnels that protrude from the ground meters above their subterranean nests. It is widely accepted that the purpose of these mounds is to give the colony a controlled microclimate in which to raise fungus and brood by managing heat, humidity, and respiratory gas exchange. Although different hypotheses such as steady and fluctuating external wind and internal metabolic heating have been proposed for ventilating the mound, the absence of direct in situ measurement of internal air flows has precluded a definitive mechanism for this critical physiological function. By measuring diurnal variations in flow through the surface conduits of the mounds of the species Odontotermes obesus, we show that a simple combination of geometry, heterogeneous thermal mass, and porosity allows the mounds to use diurnal ambient temperature oscillations for ventilation. In particular, the thin outer flutelike conduits heat up rapidly during the day relative to the deeper chimneys, pushing air up the flutes and down the chimney in a closed convection cell, with the converse situation at night. These cyclic flows in the mound flush out CO2 from the nest and ventilate the colony, in an unusual example of deriving useful work from thermal oscillations.

  20. Preliminary study of ammonia emissions from naturally ventilated fattening pig houses in the south-east China

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K.; Ye, Z.; Li, H. [Zhejiang Univ., Hangzhou City (China). School of Biosystems Engineering and Food Science

    2010-07-01

    This paper reported on an experimental simulation in which ammonia emissions from naturally ventilated pig houses were monitored and the ventilation airflow rate was estimated. Two identical pig houses and the same number of pigs were used in the study. Natural ventilation was used in the experimental pig house while the reference pig house had mechanical ventilation. Both houses had the same air temperature and relative humidity. The ventilation airflow rate of the experimental pig house was estimated by calculating the ventilation airflow rate in the reference pig house. The ventilation airflow rate of the experimental pig house was also estimated based on heat pressure theory. The room air temperature and relative humidity were found to be related to inlet air temperature and relative humidity for both ventilation systems. After 19 days, the average air temperature in the room with mechanical ventilation was about 4.1 degrees C higher than inlet air temperature, but the relative humidity was lower by 7.1 per cent. In the room with natural ventilation, the average air temperature after 19 days was about 3.9 degrees C higher than inlet air temperature, but the relative humidity was lower by 4.3 per cent.

  1. Fire protection countermeasures for containment ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-08-25

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified.

  2. Modelling The Energy Performance Of Night-Time Ventilation Using The Quasi-Steady state Calculation Method

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    the convective heat transfer by ventilation using the factor Cve (method proposed in the standard), and the other one introduces an adjustment factor Cy on the relative heat gains. 288 simulations of a typical Danish office building have been performed using different boundary conditions: level of thermal mass......Many European countries assess the heating and cooling needs of buildings using the quasi-steady state calculation method described in EN ISO 13790. The energy need is calculated by establishing the monthly balance of heat losses and heat gains, and the dynamic effects are taken into consideration......, level of insulation, orientation, internal heat loads, duration and air change rate of night-time ventilation. For both methods, the derived correction factors are highly dependent on the thermal mass of the building. An influence of the period of activation of night-time ventilation has also been...

  3. Induction Heating Systems

    Science.gov (United States)

    1991-01-01

    Induction heating technology, a magnetic non-deforming process, was developed by Langley researchers to join plastic and composite components in space. Under NASA license, Inductron Corporation uses the process to produce induction heating systems and equipment for numerous applications. The Torobonder, a portable system, comes with a number of interchangeable heads for aircraft repair. Other developments are the E Heating Head, the Toroid Joining Gun, and the Torobrazer. These products perform bonding applications more quickly, safely and efficiently than previous methods.

  4. [Nasopharyngeal myiasis during mechanical ventilation].

    Science.gov (United States)

    Yoshitomi, A; Sato, A; Suda, T; Chida, K

    1997-12-01

    We report a case of myiasis caused by Phaenicia sericata during mechanical ventilation. An 86-year-old woman with bronchiectasis was admitted to our hospital with severe respiratory failure. Treatment with mechanical ventilation and sedatives was initiated. On the 10th day of hospitalization, about 20 white larvae were found in the patient's oral or nasal cavities. The larvae were removed and identified as Phaenicia sericata. No mucosal injury was found in the patient's oral or nasal cavity by endoscopic examination. The patient died of multiple organ failure caused by sepsis that had no association with myiasis. From the clinical course and the fly's life cycle, it is considered that the fly laid eggs in the patient's oral or nasal cavity while she was sedated during mechanical ventilation. Myiasis can occur even in a hospital.

  5. DNA repair. [UV radiation

    Energy Technology Data Exchange (ETDEWEB)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals. (HLW)

  6. HEAT AND AIR MODES OF AGRICULTURAL STRUCTURES

    Directory of Open Access Journals (Sweden)

    Kharchenko P. M.

    2016-06-01

    Full Text Available In this article, there are descriptions of ventilation systems of municipal and industrial buildings. We consider the scheme of natural ventilation and ventilation with mechanical drive. In agriculture production, processes accompanied by the releasing into the air of premises various harmful substances: gases and vapors, excess of heat and moisture. The source of the fumes and gases are various technological processes. People, animals and birds in the premises, release carbon dioxide and other gases. Sources of heat gain are the people, animals and birds, solar radiation, production equipment and so on. For optimization of parameters of the air environment, satisfying the hygienic requirements, need to install ventilation. The ventilation system – it is a set of devices for handling, transportation, supply and removal of air. The advantage of this article is the systematization of ventilation systems of production premises. We have identified the main flows of indoor air and placement of exhaust shafts. Greatest interest are the systems operating year-round or during the heat period and exhaust systems equipped with control devices in the form of a throttle valves or gate valves and a device for cleaning the air. We give sufficient attention to the thermal regime of premises, heat losses and heat gain through protecting designs. We indicated that a significant effect on the thermal state of premises might be provided by humidity level of fences, as well as potential of heat and moisture transfer

  7. Ventilation, indoor air quality, and health in homes undergoing weatherization.

    Science.gov (United States)

    Francisco, P W; Jacobs, D E; Targos, L; Dixon, S L; Breysse, J; Rose, W; Cali, S

    2017-03-01

    Ventilation standards, health, and indoor air quality have not been adequately examined for residential weatherization. This randomized trial showed how ASHRAE 62-1989 (n=39 houses) and ASHRAE 62.2-2010 (n=42 houses) influenced ventilation rates, moisture balance, indoor air quality, and self-reported physical and mental health outcomes. Average total airflow was nearly twice as high for ASHRAE 62.2-2010 (79 vs. 39 cfm). Volatile organic compounds, formaldehyde and carbon dioxide were all significantly reduced for the newer standard and first-floor radon was marginally lower, but for the older standard, only formaldehyde significantly decreased. Humidity in the ASHRAE 62.2-2010 group was only about half that of the ASHRAE 62-1989 group using the moisture balance metric. Radon was higher in the basement but lower on the first floor for ASHRAE 62.2-2010. Children in each group had fewer headaches, eczema, and skin allergies after weatherization and adults had improvements in psychological distress. Indoor air quality and health improve when weatherization is accompanied by an ASHRAE residential ventilation standard, and the 2010 ASHRAE standard has greater improvements in certain outcomes compared to the 1989 standard. Weatherization, home repair, and energy conservation projects should use the newer ASHRAE standard to improve indoor air quality and health. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

    Directory of Open Access Journals (Sweden)

    Eduardo Mireles-Cabodevila

    2012-01-01

    Full Text Available Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes. Two examples are adaptive support ventilation (ASV and mid-frequency ventilation (MFV. We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care clinicians provided reference ventilator settings for a 70 kg paralyzed patient in five clinical/physiological scenarios. The survey-derived values for minute ventilation and minute alveolar ventilation were used as goals for ASV and MFV, respectively. A lung simulator programmed with each scenario’s respiratory system characteristics was ventilated using the clinician, ASV, and MFV settings. Results. Tidal volumes ranged from 6.1 to 8.3 mL/kg for the clinician, 6.7 to 11.9 mL/kg for ASV, and 3.5 to 9.9 mL/kg for MFV. Inspiratory pressures were lower for ASV and MFV. Clinician-selected tidal volumes were similar to the ASV settings for all scenarios except for asthma, in which the tidal volumes were larger for ASV and MFV. MFV delivered the same alveolar minute ventilation with higher end expiratory and lower end inspiratory volumes. Conclusions. There are differences and similarities among initial ventilator settings selected by humans and computers for various clinical scenarios. The ventilation outcomes are the result of the lung physiological characteristics and their interaction with the targeting scheme.

  9. The School Advanced Ventilation Engineering Software (SAVES)

    Science.gov (United States)

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  10. The practice of mine ventilation engineering

    Institute of Scientific and Technical Information of China (English)

    Wallace Keith; Prosser Brian; Stinnette J. Daniel

    2015-01-01

    The practice of ventilation is continually evolving with new technological advances developed in the mining industry. In recent years the advances in diesel engine technologies, ventilation modeling software, and ventilation management capacities have redefined the historical methods used to evaluate systems. The advances re-evaluate previous methods used to calculate the airflow requirements for the dilution of diesel exhaust fumes. Modeling software has become an integral part of planning and devel-oping ventilation systems in partnership with graphical mine design software packages to generate realistic representations of the mine. Significant advances in ventilation control strategies through remote sensors and monitoring capabilities have been developed to results in cost savings. Though there has been much advancement in mine ventilation technology, the practices and basic ventilation princi-pals enacted through the ventilation engineer cannot be placated with technological advances only.

  11. Intraoperative mechanical ventilation for the pediatric patient.

    Science.gov (United States)

    Kneyber, Martin C J

    2015-09-01

    Invasive mechanical ventilation is required when children undergo general anesthesia for any procedure. It is remarkable that one of the most practiced interventions such as pediatric mechanical ventilation is hardly supported by any scientific evidence but rather based on personal experience and data from adults, especially as ventilation itself is increasingly recognized as a harmful intervention that causes ventilator-induced lung injury. The use of low tidal volume and higher levels of positive end-expiratory pressure became an integral part of lung-protective ventilation following the outcomes of clinical trials in critically ill adults. This approach has been readily adopted in pediatric ventilation. However, a clear association between tidal volume and mortality has not been ascertained in pediatrics. In fact, experimental studies have suggested that young children might be less susceptible to ventilator-induced lung injury. As such, no recommendations on optimal lung-protective ventilation strategy in children with or without lung injury can be made.

  12. A new integrated design tool for naturally ventilated buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, P.G. [Centre for Experimental and Numerical Thermoflow (CENT), Dept. of Mechanical and Aeronautical Engineering, Univ. of Pretoria (South Africa); Mathews, E.H. [Centre for Experimental and Numerical Thermoflow (CENT), Dept. of Mechanical and Aeronautical Engineering, Univ. of Pretoria (South Africa)

    1996-03-01

    In many cases natural ventilation may be sufficient to ensure acceptable comfort levels in occupied buildings. In these cases, installation of energy-intensive active environmental control systems will not be necessary. This will result in considerable energy and cost savings and also indirectly in a reduced burden on the environment, since the use of energy is always associated with the production of waste materials. This paper decribes the development of a new model to predict natural ventilation flow rates in buildings. The model is based on the concept of a flow network where openings are represented by non-linear flow resistances. It takes into account the effect of both wind-induced pressures and pressures due to thermal forces. The model draws on a healthy balance between purely theoretical equations and empirical data. The new flow model was linked to an existing thermal model to produce a new integrated design tool for naturally ventilated buildings. It takes into account the important interaction between the flow model and the thermal model and can therefore be used to predict the natural ventilation flow rates as well as the resulting indoor air temperatures. The applicability of the new tool is illustrated through a case study. From this it is clear that the tool can be used successfully to optimize passive building design. The optimized design illustrated here not only resulted in minimum initial cost, but also in improved passive thermal comfort in summertime and a reduction in winter heating energy consumption. (orig.)

  13. ASHRAE Standard 62: tobacco industry's influence over national ventilation standards.

    Science.gov (United States)

    Bialous, S Aguinaga; Glantz, S A

    2002-12-01

    To describe the role of the tobacco industry in the development of ventilation standards for indoor air quality by influencing the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE). Review of tobacco industry documents available on the internet between January 2001 and March 2002. Search terms included "ASHRAE", "ventilation", "minutes", "memo", and the names of key players and organisations as identified in the initial searches. Analysis of ASHRAE and other relevant documents publicly available and the personal files of a Standard 62 committee member; interviews of a selected number of ASHRAE players; observation of an ASHRAE meeting. The tobacco industry has been involved in the development of ventilation standards for over 20 years. It has successfully influenced the standard and continues to attempt to change the standard from a smoke-free framework into an "accommodation" framework. The industry acts directly and through consultants and allies. The major health groups have been largely absent and the health interests have been poorly represented in standard development. While concentrated in the USA, ASHRAE standards are adopted worldwide. The tobacco industry determined that allowing smoking in ventilation standards for indoor air quality was a high priority and dedicated significant human and financial resources to ensure that its interests were represented. The health groups, until recently, have largely ignored the policy implications for tobacco control of standard development. This situation is changing, but unless health groups maintain high visibility within ASHRAE, the tobacco industry may succeed in creating a standard that ignores the dangers of secondhand smoke.

  14. Iatrogenic pneumothorax related to mechanical ventilation

    OpenAIRE

    2014-01-01

    Pneumothorax is a potentially lethal complication associated with mechanical ventilation. Most of the patients with pneumothorax from mechanical ventilation have underlying lung diseases; pneumothorax is rare in intubated patients with normal lungs. Tension pneumothorax is more common in ventilated patients with prompt recognition and treatment of pneumothorax being important to minimize morbidity and mortality. Underlying lung diseases are associated with ventilator-related pneumothorax with...

  15. Evaluation of Security of Mine Ventilation Systems

    Institute of Scientific and Technical Information of China (English)

    何书建; 彭担任; 翟成

    2002-01-01

    A mine ventilation system has a deterministic function for the safety of coal production and for the control of mine accidents. So, it has an importa nt meaning to evaluate the security of a mine ventilation system. This paper studied the evaluation index system of the security of a mine ventilation system, and the security of a mine ventilation system was described quantitatively in the saf ety degree. Finally, an example of the security evaluation was given .

  16. Functionality of Ventilated Facades: Protection of Insulation

    OpenAIRE

    Petrichenko Mikhail; Musorina Tatiana; Statsenko Elena; Ostrovaia Anastasia; Tarasov Vladimir

    2016-01-01

    This article discusses about methods of construction of the ventilated facades. The ventilated facade is not only the element of facing, it is the supporting structure. Their main objective - creation of air ventilating space between a facade and an external wall of the building. Moving of air in this gap protects a heater from destruction, interfering with a moisture congestion. In addition, the ventilated facade protect the building from aggressive influence of external environment, have a ...

  17. Design of Ventilation and Smoke Control in Underground Garage%地下车库通风与防排烟系统设计的探讨

    Institute of Scientific and Technical Information of China (English)

    陈英杰; 朱勇军; 郭荣春; 于炜龙

    2014-01-01

    对比GB50016-2006《建筑设计防火规范》、GB 50045-95《高层民用建筑设计防火规范》、《全国民用建筑工程设计技术措施-暖通空调。动力》(2009版)和《汽车库、修车库、停车场设计防火规范》中关于地下车库的通风排烟系统设计方面的内容,探讨了车库的送风量、平时排风量与消防排烟量计算方法和排烟排风合用的设计要点,阐述了地下汽车库的排烟系统与通风系统兼用的实用性[1-4]。%the content of the ventilation and smoke exhaust for underground garage in Code of Design on Building Fire Protection and Prevention (GB50016-2006), Code for Fire Protection Design of Tall Build-ings (GB 50045-95), National Technical Measures for Design of Civil Construction(Heating, Ventilation and Air Conditioning), and Code for Fire Protection Design of Garage, Motor Repair Shop and Parking Area (GB50067-97) are compared, discussing about the design points of combination of smoke and exhaust sys-tem and calculation method of air output, exhaust air and exhaust smoke volume of exhaust systems and ventilation systems in underground garage. It is possible and economic to use one system only instead of two different systems.

  18. Solar chimney design: Investigating natural ventilation and cooling in offices with the aid of computer simulation

    Science.gov (United States)

    Angelis, Nikolaos

    Solar chimney design is investigated as a means of improving natural ventilation and passive cooling in office buildings. Existing scientific research and built precedents are generally limited literature review findings on various features of solar chimneys were categorised and used to develop a building simulation strategy. Using UK climatic data, simulations were performed on several computer models in order to investigate solar chimney performance during a single day period and an entire cooling season. Passive cooling with a solar chimney is possible but actual reduction in temperatures in most cases examined could be negligible. Cooling potential is increased on still, warm days, while the prospects for night cooling are further improved. A solar chimney may help reduce considerably the occurrence of resultant temperatures at or above the 25 C and 28 C thresholds. Solar chimney width, height, apertures and integral use of thermal mass are the most significant parameters for cooling. Simulation results showed that a solar chimney can increase significantly natural ventilation rates. Total ventilation rates may be increased by at least 22%. During still days a solar chimney can enhance ventilation rates by 36% or more. Stack ventilation through a solar chimney is typically 20% of cross ventilation during night time this may increase to at least 40-45% and on still days it may reach 100% of typical cross ventilation rates. Solar chimney induced stack ventilation and cross ventilation are interrelated. Resultant air flow patterns may have an important effect on convective heat transfers and thermal comfort. Climate and microclimate conditions should be an integral part of solar chimney design. Key aspects and recommendations regarding solar chimneys, passive cooling and natural ventilation are provided for design guidance and feedback in further research.

  19. Repairing the wooden frame of chambers in coking furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Nador, Y.; Iruti, M.; Komiya, S.; Matsuno, T.; Ogavakhara, F.

    1983-02-12

    A method and device are proposed for hot repair of the door frames of coking chanbers. The repair is conducted prior to discharge of the coke from the chamber without its cooling or a reduction in temperature. After the doors are removed, a screening plate fettled with a heat insulation material on the chamber side is introduced into the frame, it is attached to the door frame and the required repair is conducted.

  20. Ventilation in Commercial and Residential Buildings

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    A number of areas have to be considered in connection with indoor air quality and ventilation. The selection of ventilation principle and components in the ventilation system will have influence on the indoor air quality and this subject will be discussed on the following pages. The main object o...

  1. Why this crisis in residential ventilation

    NARCIS (Netherlands)

    Hasselaar, E.

    2008-01-01

    Ventilation is the cornerstone of good indoor air quality. Ventilation requirements have major attention in building regulations, but ventilation in practice is often poor, resulting in increased concentration of pollutants and hence exposure to health risk. Inspection of 500 houses with interviews

  2. Decisional responsibility for mechanical ventilation and weaning

    DEFF Research Database (Denmark)

    Rose, Louise; Blackwood, Bronagh; Egerod, Ingrid

    2011-01-01

    Optimal management of mechanical ventilation and weaning requires dynamic and collaborative decision making to minimize complications and avoid delays in the transition to extubation. In the absence of collaboration, ventilation decision making may be fragmented, inconsistent, and delayed. Our ob...... objective was to describe the professional group with responsibility for key ventilation and weaning decisions and to examine organizational characteristics associated with nurse involvement....

  3. Displacement Ventilation in Hospital Environments

    DEFF Research Database (Denmark)

    Li, Yuguo; Nielsen, Peter V.; Sandberg, Mats

    2011-01-01

    Hospital differ from conventional buildings in terms of ventilation needs. Exhaled infectious droplets or droplet nuclei of an infected patient need to be removed in general wards, waiting areas and isolation rooms to minimize transmission to health-care workers, other patients and visitors...

  4. Displacement Ventilation in Hospital Environments

    DEFF Research Database (Denmark)

    Li, Yuguo; Nielsen, Peter V.; Sandberg, Mats

    2011-01-01

    Hospital differ from conventional buildings in terms of ventilation needs. Exhaled infectious droplets or droplet nuclei of an infected patient need to be removed in general wards, waiting areas and isolation rooms to minimize transmission to health-care workers, other patients and visitors...

  5. International Ventilation Cooling Application Database

    DEFF Research Database (Denmark)

    Holzer, Peter; Psomas, Theofanis Ch.; OSullivan, Paul

    2016-01-01

    The currently running International Energy Agency, Energy and Conservation in Buildings, Annex 62 Ventilative Cooling (VC) project, is coordinating research towards extended use of VC. Within this Annex 62 the joint research activity of International VC Application Database has been carried out, ...

  6. Thermal Plumes in Ventilated Rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects....

  7. Computational Fluid Dynamics in Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Allard, Francis; Awbi, Hazim B.;

    2008-01-01

    Computational Fluid Dynamics in Ventilation Design is a new title in the is a new title in the REHVA guidebook series. The guidebook is written for people who need to use and discuss results based on CFD predictions, and it gives insight into the subject for those who are not used to work with CFD...

  8. Cardiogenic oscillation induced ventilator autotriggering

    Directory of Open Access Journals (Sweden)

    Narender Kaloria

    2015-01-01

    Full Text Available Cardiogenic oscillation during mechanical ventilation can auto-trigger the ventilator resembling patient initiated breadth. This gives a false sense of intact respiratory drive and determination brain death, even if other tests are positive, is not appropriate in such a situation. It will prolong the ICU stay and confound the brain-death determination. In this case report, we describe a 35 year old man who was brought to the hospital after many hours of critical delay following multiple gun shot injuries. The patient suffered a cardiac arrest while on the way from another hospital. After an emergency laparotomy, patient was shifted to Intensive Care Unit (ICU with Glasgow Coma Scale (GCS score of E1VTM1 and was mechanically ventilated. Despite absence of brainstem reflexes, the ventilator continued to be triggered on continuous positive airway pressure (CPAP mode and the patient maintained normal oxygen saturation and acceptable levels of carbon dioxide. An apnoea test confirmed absent respiratory drive. Ventilatory waveform graph analysis, revealed cardiogenic oscillation as the cause for autotrigerring.

  9. Experimental Investigation of the Influence of Obstacle in the Room on Passive Night-Time Cooling using Displacement Ventilation

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Khalegi, Farzad; Domarks, Giedrius

    2011-01-01

    Night-time ventilation is a promising approach for reducing the energy needed for cooling buildings without reducing thermal comfort. The objective of this paper is to determine how an internal obstacle, such as a table, will influence the heat transfer in the room and the efficiency of night......-time ventilation which uses displacement ventilation. Experimental work was conducted on the basis of the work in a similar previous study, performed by (Artmann 2010), and this is an extension of that work. Experimental results obtained for a case with a table were compared with the results obtained by Artmann et...... al. for a room with displacement ventilation, but without table. The results obtained in the experiment with the table indicated that the mean heat flux was slightly lower but very similar compared to the case without the table. The heat flux at the ceiling was measured to be the same for both setups...

  10. Analyze of Ventilator Associated Pneumonia

    Directory of Open Access Journals (Sweden)

    Aysel Sunnetcioglu

    2014-03-01

    Full Text Available Aim: Ventilator-associated pneumonia (VAP is the infection that is an important cause of morbidity and mortality developed in patients whom the invasive mechanical ventilation (MV were performed in intensive care units (ICU. In this study, the factors of VAP developing in patients whom the mechanical ventilation of ICU performed, antibiotic susceptibility to these factors and determining the risk factors were aimed. Material and Method: Between January 2009 and March 2013, 79 cases, followed with the mechanical ventilation for at least for 48 hours and developed VAP, were retrospectively reviewed at Anesthesiology and Intensive Care Unit of Reanimation at Faculty of Medicine at Yuzuncu Yil University, performing endotracheal intubation. The cases were evaluated in terms of microorganisms, antibiotic susceptibility and risk factors. Results: The rate of our VAP speed was calculated to be 19.68 on the day of 1000 ventilator. While a single microorganism could be isolated in 81.1% of the 74 VAP cases whose the active pathogen could be isolated, two or more than two microorganisms were isolated in 18.9% of them.While 83 of the strains (90.2% were gram-negative bacteria, 7 of them (7.6% were gram-positive bacteria. Acinetobacter spp. (40.2% was most commonly isolated as a gram-negative factor, but methicillin-resistant S. aureus (4.3% was isolated as a gram-positive factor. It was determined that the isolated factors in VAP cases were significantly resistant to the broad-spectrum antibiotics. Discussion: As a result, in patients with high-risk factors for the development of VAP, early and appropriate empirical antibiotic treatment should be started according to the results of the sensitivity of the unit and for the multi-drug-resistant microorganisms with common and high mortality.

  11. Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    by manually operable windows, or by automatically operable windows with and without an exhaust fan in operation, or by a balanced mechanical ventilation system. Indoor air temperature, relative humidity, carbon dioxide (CO2) concentration and window opening were continuously monitored for one month in non...... operable windows had the highest air temperatures and CO2 concentrations during both non-heating and heating season; the estimated average air-change rate was lowest in this classroom. The classroom with mechanical ventilation had the highest estimated average air-change rate. Windows were frequently...

  12. Evaluation of a Natural Ventilation Configuration at a Public Building

    Science.gov (United States)

    Papakonstantinou, K.; Belias, C.; Vlachakis, N.; Statharas, I.

    2007-12-01

    Wind is regarded as the popular passive cooling resource against hot climate in summer. It can transfer heat from human bodies, when the air temperature is lower than the skin temperature. This concept works indoors as well as outdoors. The present paper refers to the numerical simulation of air velocity and temperature concerning single—sided naturally ventilated buildings and more specifically the special case in which air from the external environment is brought inside the building through openings that have the same direction. The paper draws attention to the physical procedures governing air movement during the single—sided natural ventilation. The study presents a mathematical model, implemented in a general computer code, that can provide detailed information on velocity and temperature, prevailing in three-dimensional single—sided ventilated buildings with openings of any geometrical complexity, for given external meteorological conditions. The mathematical model involves the partial differential equations governing flow and heat transfer, in large enclosures. Turbulent flow is simulated and buoyancy effects are taken into account.

  13. Short-term airing by natural ventilation

    DEFF Research Database (Denmark)

    Perino, Marco; Heiselberg, Per

    2009-01-01

    traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates...... that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ....

  14. Minute ventilation at different compression to ventilation ratios, different ventilation rates, and continuous chest compressions with asynchronous ventilation in a newborn manikin

    Directory of Open Access Journals (Sweden)

    Solevåg Anne L

    2012-10-01

    Full Text Available Abstract Background In newborn resuscitation the recommended rate of chest compressions should be 90 per minute and 30 ventilations should be delivered each minute, aiming at achieving a total of 120 events per minute. However, this recommendation is based on physiological plausibility and consensus rather than scientific evidence. With focus on minute ventilation (Mv, we aimed to compare today’s standard to alternative chest compression to ventilation (C:V ratios and different ventilation rates, as well as to continuous chest compressions with asynchronous ventilation. Methods Two investigators performed cardiopulmonary resuscitation on a newborn manikin with a T-piece resuscitator and manual chest compressions. The C:V ratios 3:1, 9:3 and 15:2, as well as continuous chest compressions with asynchronous ventilation (120 compressions and 40 ventilations per minute were performed in a randomised fashion in series of 10 × 2 minutes. In addition, ventilation only was performed at three different rates (40, 60 and 120 ventilations per minute, respectively. A respiratory function monitor measured inspiration time, tidal volume and ventilation rate. Mv was calculated for the different interventions and the Mann–Whitney test was used for comparisons between groups. Results Median Mv per kg in ml (interquartile range was significantly lower at the C:V ratios of 9:3 (140 (134–144 and 15:2 (77 (74–83 as compared to 3:1 (191(183–199. With ventilation only, there was a correlation between ventilation rate and Mv despite a negative correlation between ventilation rate and tidal volumes. Continuous chest compressions with asynchronous ventilation gave higher Mv as compared to coordinated compressions and ventilations at a C:V ratio of 3:1. Conclusions In this study, higher C:V ratios than 3:1 compromised ventilation dynamics in a newborn manikin. However, higher ventilation rates, as well as continuous chest compressions with asynchronous

  15. Extracorporeal membrane oxygenation for repair of tracheal injury during transhiatal esophagectomy

    Directory of Open Access Journals (Sweden)

    Lilibeth Fermin

    2017-01-01

    Full Text Available Extracorporeal Membrane Oxygenation (ECMO for repair of tracheal injury during transhiatal esophagectomy Tracheal injury is a rare but potentially fatal complication of esophagectomies requiring prompt recognition and treatment. We describe a case of tracheal injury recognized in the operative period of an open transhiatal esophagectomy for squamous cell carcinoma of the mid to distal esophagus. When injury was discovered, attempts to improve oxygenation and ventilation by conventional methods were unsuccessful. Therefore, peripheral ECMO was used to support oxygenation during the tracheal defect repair. The use of ECMO for the repair of a tracheal injury during esophagectomy is very uncommon but, in our case, provided adequate oxygenation and ventilation while the surgeon repaired the injury and the patient was able to be promptly weaned from ECMO support and extubated not long after.

  16. Natural Ventilation of Indoor Air Temperature: A Case Study of the Traditional Malay House in Penang

    Directory of Open Access Journals (Sweden)

    Ahmad S. Hassan

    2010-01-01

    Full Text Available Problem statement: It was the aim of the study to analyze the level of performance of natural air ventilation with a case study of the traditional Malay house in Penang, Malaysia. This study provided information on the architectural design in relation to natural air ventilation. It promoted passive design in contrast to most housing design which has poor natural air ventilation because the design was orientated to energy consumption that slightly more than one third of the electric energy was used for heating, ventilating and air conditioning systems. Approach: This analysis used quantitative method which measured temperature, humidity and wind speed of the traditional house. The result indicated the level of performance of cross air ventilation and stack effect. Results: The analysis showed that the traditional house has a design integrated with natural air ventilation system. The indoor house temperature and relative humidity had slightly lower than its outdoor area. However, the indoor area had lower wind speed level than the outdoor area. Conclusion: The study showed that maximum openings on the building walls created high air intakes outside the house to give poor performance of stack effect. The design had more emphasis to cross air ventilation.

  17. Energy Impact of Residential Ventilation Norms in the UnitedStates

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2007-02-01

    The first and only national norm for residential ventilation in the United States is Standard 62.2-2004 published by the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE). This standard does not by itself have the force of regulation, but is being considered for adoption by various jurisdictions within the U.S. as well as by various voluntary programs. The adoption of 62.2 would require mechanical ventilation systems to be installed in virtually all new homes, but allows for a wide variety of design solutions. These solutions, however, may have a different energy costs and non-energy benefits. This report uses a detailed simulation model to evaluate the energy impacts of currently popular and proposed mechanical ventilation approaches that are 62.2 compliant for a variety of climates. These results separate the energy needed to ventilate from the energy needed to condition the ventilation air, from the energy needed to distribute and/or temper the ventilation air. The results show that exhaust systems are generally the most energy efficient method of meeting the proposed requirements. Balanced and supply systems have more ventilation resulting in greater energy and their associated distribution energy use can be significant.

  18. Simplified models for heat transfer in rooms

    Science.gov (United States)

    Graca, Guilherme C. C. Carrilho Da

    Buildings protect their occupants from the outside environment. As a semi-enclosed environment, buildings tend to contain the internally generated heat and air pollutants, as well as the solar and conductive heat gains that can occur in the facade. In the warmer months of the year this generally leads to overheating, creating a need for a cooling system. Ventilation air replaces contaminated air in the building and is often used as the dominant medium for heat transfer between indoor and outdoor environments. The goal of the research presented in this thesis is to develop a better understanding of the important parameters in the performance of ventilation systems and to develop simplified convective heat transfer models. The general approach used in this study seeks to capture the dominant physical processes for these problems with first order accuracy, and develop simple models that show the correct system behavior trends. Dimensional analysis, in conjunction with simple momentum and energy conservation, scaled model experiments and numerical simulations, is used to improve airflow and heat transfer rate predictions in both single and multi room ventilation systems. This study includes the three commonly used room ventilation modes: mixing, displacement and cross-ventilation. A new modeling approach to convective heat transfer between the building and the outside is presented: the concept of equivalent room heat transfer coefficient. The new model quantifies the reduction in heat transfer between ventilation air and internal room surfaces caused by limited thermal capacity and temperature variation of the air for the three modes studied. Particular emphasis is placed on cross-ventilation, and on the development of a simple model to characterize the airflow patterns that occur in this case. The implementation of the models in a building thermal simulation software tool is presented as well as comparisons between model predictions, experimental results and complex

  19. Adult patient with pulmonary agenesis: focusing on one-lung ventilation during general anesthesia

    OpenAIRE

    Yu, Yuetian; ZHU, CHENG; QIAN, XIAOZHE; Gao, Yuan; Zhang, Zhongheng

    2016-01-01

    Congenital pulmonary agenesis is a rare condition with high mortality. Mechanical ventilation in these patients is challenging and there has no such case been reported in the literature. We reported a 61-year-old female with lung agenesis who presented to our hospital with pneumonia and pelvic mass. In the past, she had undergone repairing of atrial septal defect and mitral valve forming surgery at 6-year-old. Thereafter she had remained asymptomatic until this time of hospital admission. The...

  20. Performance of ductless personalized ventilation in conjunction with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Melikov, Arsen Krikor; Vesely, Michal

    2014-01-01

    movement decreased with DPV compared to corresponding conditions with displacement ventilation alone and reached the same level as mixing or displacement ventilation at 23 °C. Subjects were able to control the volume and speed of the personalized air flow in order to avoid eye irritation. However......, increased eye dryness sensation was reported by 30% of subjects. The personalized air flow selected by nearly 80% of the subjects at 26 °C was between 10 and 20 l/s corresponding to the target air velocity of 1.2–1.7 m/s. At 29 °C almost 90% of subjects chose a personalized air flow between 15 and 20 l/s (1...

  1. Night ventilation control strategies in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhaojun; Yi, Lingli; Gao, Fusheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090 (China)

    2009-10-15

    In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

  2. Fire protection countermeasures for containment ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified.

  3. Pectus excavatum repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002949.htm Pectus excavatum repair To use the sharing features on this page, please enable JavaScript. Pectus excavatum repair is surgery to correct pectus excavatum . This ...

  4. Ventilation system design for educational facilities

    Energy Technology Data Exchange (ETDEWEB)

    Elsafty, A.F.; Abo Elazm, M.M. [Arab Academy for Science, Alexandria (Egypt). Technology and Maritime Transport; Safwan, M. [Arab Academy for Science, Cairo (Egypt). Technology and Maritime Transport

    2010-07-01

    In order to maintain acceptable indoor air quality levels in classrooms, high ventilation rates are needed to dilute the concentration of indoor contaminants, resulting in higher energy consumption for the operation of mechanical ventilation systems. Three factors are usually considered when determining the adequate ventilation rate for classrooms in educational facilities. These include the maximum population served in the classroom; carbon dioxide (CO{sub 2}) production rate by occupants; and outdoor air conditions. CO{sub 2} concentrations usually indicate the rate of ventilation required. This paper presented a newly developed computer software program for determining the ventilation rates needed to enhance indoor air quality and to maintain CO{sub 2} concentration within the recommended levels by ANSI/ASHRAE standards for best student performance. This paper also presented design curves for determining the ventilation rates and air changes per hour required for the ventilated educational zone. 15 refs., 2 tabs., 5 figs.

  5. Measuring Air Temperature in Glazed Ventilated Facades in the Presence of Direct Solar Radiation

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Zanghirella, Fabio; Heiselberg, Per

    2007-01-01

    A distinctive element of buildings with a double glazed façade is naturally or mechanically driven flow in a ventilated cavity. Accurate air temperature measurements in the cavity are crucial to evaluate the dynamic performance of the façade, to predict and control its behavior as a significant...... part of the complete ventilation system. Assessment of necessary cooling/heating loads and of the whole building energy performance will then depend on the accuracy of measured air temperature. The presence of direct solar radiation is an essential element for the façade operation, but it can heavily...... irradiance, in order to achieve an accurate and reliable way to measure the air temperature reducing the error caused by radiation. Experiments include bare thermocouple, naturally and mechanically ventilated shielded thermocouples, mechanically ventilated thermocouple with double shielding, silver coated...

  6. Effectiveness and Discussion of Ventilation Design with Automatic Revolving Window

    Directory of Open Access Journals (Sweden)

    Chang Jing Yi

    2016-01-01

    Full Text Available This paper aims to improve and discuss the effectiveness of automatic revolving window ventilation on human comfort, where the temperature sensor mounted indoors gives the signal to start the stepping motor of the revolving window. There is a controller for automatic regulation according to the difference between the preset temperature and indoor temperature, where the air flow of ventilating fan imports outside air to take excess heat away from the room, in order to reduce the indoor temperature. The revolving window opening angle is simulated and analyzed, and the impact of different air rates on the indoor temperature is analyzed. This system can regulate the indoor temperature to effectively reach the optimal human comfort temperature, and can reduce the frequency of using air conditioning, in order to attain the goals of energy saving, carbon reduction, and environmental protection.

  7. Summary of human responses to ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli A.; Fisk, William J.

    2004-06-01

    The effects of ventilation on indoor air quality and health is a complex issue. It is known that ventilation is necessary to remove indoor generated pollutants from indoor air or dilute their concentration to acceptable levels. But, as the limit values of all pollutants are not known, the exact determination of required ventilation rates based on pollutant concentrations and associated risks is seldom possible. The selection of ventilation rates has to be based also on epidemiological research (e.g. Seppanen et al., 1999), laboratory and field experiments (e.g. CEN 1996, Wargocki et al., 2002a) and experience (e.g. ECA 2003). Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated as summarized by Seppdnen (2003). Ventilation may bring indoors harmful substances that deteriorate the indoor environment. Ventilation also affects air and moisture flow through the building envelope and may lead to moisture problems that deteriorate the structures of the building. Ventilation changes the pressure differences over the structures of building and may cause or prevent the infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. Ventilation can be implemented with various methods which may also affect health (e.g. Seppdnen and Fisk, 2002, Wargocki et al., 2002a). In non residential buildings and hot climates, ventilation is often integrated with air-conditioning which makes the operation of ventilation system more complex. As ventilation is used for many purposes its health effects are also various and complex. This paper summarizes the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus of the paper is on office-type working environment and residential buildings. In the industrial premises the problems of air quality are usually

  8. When "Other" Initiate Repair.

    Science.gov (United States)

    Schegloff, Emanuel A.

    2000-01-01

    Elaborates on the locus of other-initiated repair, and reports on a number of environments in which others initiate repair turns later than the one directly following the trouble-source turn. Describes several ways that other initiation of repair, which occurs in next-turn position, may be delayed within that position. (Author/VWL)

  9. A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study.

    Science.gov (United States)

    Rosbach, Jeannette T M; Vonk, Machiel; Duijm, Frans; van Ginkel, Jan T; Gehring, Ulrike; Brunekreef, Bert

    2013-12-17

    Classroom ventilation rates often do not meet building standards, although it is considered to be important to improve indoor air quality. Poor indoor air quality is thought to influence both children's health and performance. Poor ventilation in The Netherlands most often occurs in the heating season. To improve classroom ventilation a tailor made mechanical ventilation device was developed to improve outdoor air supply. This paper studies the effect of this intervention. The FRESH study (Forced-ventilation Related Environmental School Health) was designed to investigate the effect of a CO2 controlled mechanical ventilation intervention on classroom CO2 levels using a longitudinal cross-over design. Target CO2 concentrations were 800 and 1200 parts per million (ppm), respectively. The study included 18 classrooms from 17 schools from the north-eastern part of The Netherlands, 12 experimental classrooms and 6 control classrooms. Data on indoor levels of CO2, temperature and relative humidity were collected during three consecutive weeks per school during the heating seasons of 2010-2012. Associations between the intervention and weekly average indoor CO2 levels, classroom temperature and relative humidity were assessed by means of mixed models with random school-effects. At baseline, mean CO2 concentration for all schools was 1335 ppm (range: 763-2000 ppm). The intervention was able to significantly decrease CO2 levels in the intervention classrooms (F (2,10) = 17.59, p < 0.001), with a mean decrease of 491 ppm. With the target set at 800 ppm, mean CO2 was 841 ppm (range: 743-925 ppm); with the target set at 1200 ppm, mean CO2 was 975 ppm (range: 887-1077 ppm). Although the device was not capable of precisely achieving the two predefined levels of CO2, our study showed that classroom CO2 levels can be reduced by intervening on classroom ventilation using a CO2 controlled mechanical ventilation system.

  10. Occupant Interactions and Effectiveness of Natural Ventilation Strategies in Contemporary New Housing in Scotland, UK

    Directory of Open Access Journals (Sweden)

    Tim Sharpe

    2015-07-01

    Full Text Available The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in “healthy” Indoor Air Quality (IAQ in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for “adequate” ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of “trickle ventilators open plus doors open” gave an average of 1021 ppm. “Trickle ventilators open” gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported

  11. Influence of a Cooled Ceiling on Indoor Air Quality in a Displacement Ventilated Room Examined by Means of Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Brohus, Henrik

    The influence of a cooled ceiling on the air quality in a displacement ventilated room is examined by means of CFD. The objective of the study is to examine how the flow field in a displacement ventilated room is influenced when a cooled ceiling removes a major part of the total heat I9ad...

  12. Advanced maintenance, inspection & repair technology for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hinton, B.M.

    1994-12-31

    Maintenance, inspection, and repair technology for nuclear power plants is outlined. The following topics are discussed: technology for reactor systems, reactor refueling bridge, fuel inspection system, fuel shuffling software, fuel reconstitution, CEA/RCCA/CRA inspection, vessel inspection capabilities, CRDM inspection and repair, reactor internals inspection and repair, stud tensioning system, stud/nut cleaning system, EDM machining technology, MI Cable systems, core exit T/C nozzle assemblies, technology for steam generators, genesis manipulator systems, ECT, UT penetrant inspections, steam generator repair and cleaning systems, technology for balance of plant, heat exchangers, piping and weld inspections, and turbogenerators.

  13. Design of passive cooling by night ventilation: evaluation of a parametric model and building simulation with measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pfafferott, J.; Herkel, S.; Jaeschke, M. [Fraunhofer-Institute for Solar Energy Systems, Freiburg (Germany)

    2003-12-01

    At the new institute building of Fraunhofer ISE, both mechanical and free night ventilation is used for passive cooling of the offices. The results from a long-term monitoring show, that room temperatures are comfortable even at high ambient air temperatures. In two offices, experiments were carried out in order to determine the efficiency of night ventilation dependent on air change rate, solar and internal heat gains. The aim is to identify characteristic building parameters and to determine the night ventilation effect with these parameters. The experiments (one room with and one without night ventilation) are evaluated by using both a parametric model and the ESP-r building simulation programme. Both models are merged in order to develop a method for data evaluation in office buildings with night ventilation and to provide a simple model for integration in a building management system. (Author)

  14. The Histoty of Ventilation and Air Conditioning is CERN Up to Date with the latest Technological Developments?

    CERN Document Server

    Kühnl-Kinel, J

    2000-01-01

    The invention of ventilation cannot be ascribed to a certain date. It started with simple aeration when man brought fire into his abode and continued through different stages including air cooling using ice to finally arrive at the time when ventilation and air conditioning has become an essential part of our life and plays an important role in human evolution. This paper presents the history of ventilation and air conditioning, explains the key constraints over the centuries, and shows its influence on everyday life. Some examples of previous air-conditioning plants are described and different approaches to the way of calculation of ventilation systems discussed. It gives an overview of the Heating, Ventilation and Air Conditioning (HVAC) installations at CERN and points out their particularities. It also compares them with the latest technological developments in the field as well as showing the new trends that are being applied at CERN.

  15. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  16. Comparison of Active and Passive Humidifiers on Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    H. Dilek Mersin Özcanoğlu

    2010-12-01

    Full Text Available Objective: To research the effectiveness on humidifying, respiratory mechanics, bacterial colonization and infection rates of continuous usage for 96 hours of active and passive humidifiers which are used for heating and moisturizing the inspired gases in patients under mechanical ventilation. Materials and Methods: Adult patients who are expected to support at least 4 days under mechanical ventilation, excluding patients with primary lung disease and sepsis, are included in the research. Patients are separated in two groups as a passive humidifier group (heat moisture exchange filter (n=16 and an active humidifier group (n=14. In passive humidifier group, humidifier is used continuously for 96 hours without change. In active humidifier group moisturizing is obtained by using sterile distilled water in heated humidifier. Patients whose demographic characteristics were recorded and first 24 hour APACHE II scores were calculated, were taking chest X-Ray’s daily. Respiratory mechanics measurements were recorded twice a day which were watched in Servo300A ventilators respiratory mechanics monitor, in patients under volume controlled ventilation. The amount of moisture and liquidity of the secretion in endotracheal tube were recorded and scored visually. The endotracheal aspiration samples at the beginning and at the end of 96th hour and respiratory circuits ventilator side sample taken at 96th hour were studied microbiologically. Cultures and colonial counts were studied at Cerrahpasa Medical Faculty Microbiology Laboratory. Results: There were no significant difference in two groups by demographic data, APACHE II scores and illness diagnoses. In passive humidifier group, respiratory mechanics showed no significant difference between the beginning and the 4th day (p>0.05. In active humidifier group when MAP, PEEPtot, EEF, Rins, Rexp values showed no significant difference between the beginning and the 4th day but PIP values showed significant

  17. Percutaneous mitral valve repair.

    Science.gov (United States)

    Gillinov, A Marc; Liddicoat, John R

    2006-01-01

    Surgical mitral valve repair is the procedure of choice to treat mitral regurgitation of all etiologies. Whereas annuloplasty is the cornerstone of mitral valve repair, a variety of other surgical techniques are utilized to correct dysfunction of the leaflets and subvalvular apparatus; in most cases, surgical repair entails application of multiple repair techniques in each patient. Preclinical studies and early human experience have demonstrated that some of these surgical repair techniques can be performed using percutaneous approaches. Specifically, there has been great progress in the development of novel technology to facilitate percutaneous annuloplasty and percutaneous edge-to-edge repair. The objectives of this report were to (1) discuss the surgical foundations for these percutaneous approaches; (2) review device design and experimental and clinical results of percutaneous valve repair; and (3) address future directions, including the key challenges of patient selection and clinical trial design.

  18. A First Approach to Natural Thermoventilation of Residential Buildings through Ventilation Chimneys Supplied by Solar Ponds

    Directory of Open Access Journals (Sweden)

    Ferdinando Salata

    2015-07-01

    Full Text Available The exploitation of natural ventilation is a good solution to improve buildings from an energetic point of view and to fulfill the requirements demanded by the thermohygrometric comfort and the air quality in enclosed spaces. Some past researches demonstrated how some devices, useful to this purpose, follow the principles of solar chimneys and are able to move air masses while exploiting the Archimedes thrust. The natural ventilation must be supplied by a flow moving upward, generated by a heat source performing at temperatures slightly higher than the one present in the environment. To have a minimum energetic effect, the heat can be extracted from solar ponds; solar ponds are able to collect and store solar energy in the geographical regions characterized by sufficient values of solar radiation. Thus it is possible, in summer, to provoke a nocturnal natural ventilation useful for the air change in indoor spaces (in those climatic areas where, during the night, there is a temperature gradient.

  19. Parametrical analysis on the diffuse ceiling ventilation by experimental and numerical studies

    DEFF Research Database (Denmark)

    Zhang, Chen; Kristensen, Martin Heine; Jensen, Jakob Sølund;

    2016-01-01

    This paper aims to investigate the performance of diffuse ceiling ventilation in a classroom. An experimental study is carried out in a test chamber to examine the impact of diffuse ceiling opening area on the system cooling capacity and thermal comfort. The results indicate that diffuse ceiling...... ventilation provides a satisfied thermal comfort level in the occupied zone even under a high ventilation rate and a high heat load condition. A design chart method is adopted to compare different diffuse ceiling configurations, and the results indicate that the system with a 18% diffuse ceiling opening area....... The numerical results reveal that even distribution of heat sources gives a lower draught risk environment than centralized distribution. In addition, there is a significant increase on the draught risk with increase of room height....

  20. Urban ventilation corridors mapping using surface morphology data based GIS analysis

    Science.gov (United States)

    Wicht, Marzena; Wicht, Andreas; Osińska-Skotak, Katarzyna

    2017-04-01

    This paper describes deriving the most appropriate method for mapping urban ventilation corridors, which, if properly designed, reduce heat stress, air pollution and increase air quality, as well as increase the horizontal wind speed. Urban areas are - in terms of surface texture - recognized as one of the roughest surfaces, which results in wind obstruction and decreased ventilation of densely built up areas. As urban heat islands, private household and traffic emissions or large scale industries occur frequently in many cities, both in temperate and tropical regions. A proper ventilation system has been suggested as an appropriate mitigation mean [1] . Two concepts of morphometric analyses of the urban environment are used on the example of Warsaw, representing a dense, urban environment, located in the temperate zone. The utilized methods include firstly a roughness mapping calculation [2] , which analyses zero plane displacement height (zd) and roughness length (z0) and their distribution for the eight (inter-)cardinal wind directions and secondly a grid-based frontal area index mapping approach [3] , which uses least cost path analysis. Utilizing the advantages and minimizing the disadvantages of those two concepts, we propose a hybrid approach. All concepts are based on a 3D building database obtained from satellite imagery, aided by a cadastral building database. Derived areas (ventilation corridors), that facilitate the ventilation system, should be considered by the local authorities as worth preserving, if not expanding, in order to improve the air quality in the city. The results also include designation of the problematic areas, which greatly obscure the ventilation and might be investigated as to reshape or rebuilt to introduce the air flow in particularly dense areas like city centers. Keywords: roughness mapping; GIS; ventilation corridors; frontal area index Rizwan, A. M., Dennis, L. Y., & Chunho, L. I. U. (2008). A review on the generation

  1. CFD Analysis of Automotive Ventilated Disc Brake Rotor

    Directory of Open Access Journals (Sweden)

    Amol V. More

    2014-04-01

    Full Text Available Disc brakes work on the principle of friction by converting kinetic energy into heat energy. The key objective of a disc brake rotor is to accumulate this heat energy and dissipate it immediately. The effect of rotational speed on the aero-thermal performance is assessed. The rotor speed is observed to have substantial effect on the rotor performance. The heat dissipation and thermal performance of ventilated brake discs intensely be influenced by the aerodynamic characteristics of the air flow through the rotor passages. In order to investigate the aero-thermal performance of the ventilated disc brake at several altered driving speeds of the vehicle, the simulations were carried out at 3 different rotational speeds of 44rad/s 88 rad/s and 120 rad/s. The semi-automatic geometric model is created using the package Solid Works and the mesh for the model is done using ICEM CFD and the Post processing of the results is done using FLUENT-14.5.The results are discussed and presented in detail.

  2. Implementation of ventilation in existing schools

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    Present paper analyses the best-practice solutions for classrooms’ ventilation that fit the objective of quick and inexpensive implementation. The paper decomposes the relations between ventilation and building into manageable elements and analyzes them. The analyses are performed qualitatively......; they evaluate both scientific and practical implementation The analyses lead to a list of criteria associated with the implementation of ventilation in existing schools. Generic retrofitting scenarios which prioritize energy savings, indoor climate and building/facade integration are assembled and illustrated...

  3. Luftkvalitet i nyere skoler uden mekanisk ventilation

    DEFF Research Database (Denmark)

    Aggerholm, Søren

    I skoler uden mekanisk ventilation må der udluftes konsekvent for at forbedre luftkvaliteten. Rapporten viser resultatet af målinger af kuldioxidkoncentrationen i fire skoler uden mekanisk ventilation og én skole med mekanisk udsugning. Kuldioxidkoncentrationen er brugt som indikator...... for luftkvaliteten. Rapporten beskriver desuden de energimæssige konsekvenser ved at etablere mekanisk ventilation. Resultaterne har især interesse for skoleforvaltninger og rådgivende teknikere....

  4. Single-lung ventilation in pediatric anesthesia.

    Science.gov (United States)

    Choudhry, Dinesh K

    2005-12-01

    Single-lung ventilation is requested for an increasing spectrum of surgical procedures in infants and children. A clear understanding of the physiology of single-lung ventilation, the techniques of lung separation, and the technical skill necessary to apply these techniques are essential for an anesthesiologist practicing thoracic anesthesia. This article focuses on various devices available for single-lung ventilation in the pediatric age group, the relevant respiratory physiology, and the strategies that optimize oxygenation during one-lung anesthesia.

  5. Development and Operation of Decentralized Ventilation for Indoor Climate and Energy Performance

    DEFF Research Database (Denmark)

    Smith, Kevin Michael

    fan power, and the potential for local heat recovery. This research developed, assessed, and investigated two single-room ventilation units. One development yielded a novel short plastic rotary heat exchanger and another yielded a novel spiral plastic recuperative heat exchanger. Thermal theory guided...... on anticipated improvements. Simulations of a renovated apartment in Denmark compared the demand-controlled single-room unit to a whole-dwelling unit. Convention and regulations determined the constant flow rates for the whole-dwelling system, whereas a controller determined flow rates in the single-room units...... based on sensed values of CO2, relative humidity, and temperature. Both types of ventilation provided suitable indoor climate. In a comparison, the single-room unit improved or maintained air quality and thermal comfort while consuming less annual energy for fans and space heating. This provided...

  6. Naturlig ventilation kombineret med varmegenvinding og natkøling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker

    2007-01-01

    Naturlig ventilation i kontorbyggerier har været et alternativ til mekanisk ventilation i små 10 år. Ventilation med naturlige drivkræfter har den klare fordel, at der ikke forbruges elenergi ved ventilering af bygningen, fordi ventilatorer ikke er påkrævet. Imidlertid lider naturlig ventilation...

  7. Sustained inflation at birth did not alter lung injury from mechanical ventilation in surfactant-treated fetal lambs.

    Directory of Open Access Journals (Sweden)

    Noah H Hillman

    Full Text Available BACKGROUND: Sustained inflations (SI are used with the initiation of ventilation at birth to rapidly recruit functional residual capacity and may decrease lung injury and the need for mechanical ventilation in preterm infants. However, a 20 second SI in surfactant-deficient preterm lambs caused an acute phase injury response without decreasing lung injury from subsequent mechanical ventilation. HYPOTHESIS: A 20 second SI at birth will decrease lung injury from mechanical ventilation in surfactant-treated preterm fetal lambs. METHODS: The head and chest of fetal sheep at 126±1 day GA were exteriorized, with tracheostomy and removal of fetal lung fluid prior to treatment with surfactant (300 mg in 15 ml saline. Fetal lambs were randomized to one of four 15 minute interventions: 1 PEEP 8 cmH2O; 2 20 sec SI at 40 cmH2O, then PEEP 8 cmH2O; 3 mechanical ventilation with 7 ml/kg tidal volume; or 4 20 sec SI then mechanical ventilation at 7 ml/kg. Fetal lambs remained on placental support for the intervention and for 30 min after the intervention. RESULTS: SI recruited a mean volume of 6.8±0.8 mL/kg. SI did not alter respiratory physiology during mechanical ventilation. Heat shock protein (HSP 70, HSP60, and total protein in lung fluid similarly increased in both ventilation groups. Modest pro-inflammatory cytokine and acute phase responses, with or without SI, were similar with ventilation. SI alone did not increase markers of injury. CONCLUSION: In surfactant treated fetal lambs, a 20 sec SI did not alter ventilation physiology or markers of lung injury from mechanical ventilation.

  8. Ground-temperature controlling effects of duct-ventilated railway embankment in permafrost regions

    Institute of Scientific and Technical Information of China (English)

    NIU; Fujun; CHENG; Guodong

    2004-01-01

    Based on observed data from field-testing embankment of the Qinghai-Tibet Railway, ground-temperature controlling effect of duct-ventilated embankment is studied in this paper.The results show that ventilation ducts can effectively cool the soils surrounding the ducts of the embankment, and the heat budget of the ambient soils in a year shows as heat release. Temperature status of the permafrost below the embankment with ducts buried in the relatively high position is similar to that of the common embankment. The permafrost processes warming all along in the two freezing-thawing cycles when the embankment was constructed. However, the temperature of the frozen soils below the embankment, in which the ducts buried in the relatively low position, rises a little in the initial stage. After that, it cools down gradually. At the same time,ventilation ducts can effectively reduce the thermal disturbance caused by the filled soils. The frozen soils below the common embankment and that with high-posited ducts absorb heat all along in the initial two cycles. While the soils below the embankment with low-posited ducts begin to release heat in the second cycle. This phenomenon proves that the ventilation embankment with low-posited ducts shows efficient temperature-controlling effect. Such embankment can actively cool the subgrade soils and therefore keeps the roadbed thermally stable.

  9. Ventilation behaviour and indoor air problems in different types of newly built dwellings

    NARCIS (Netherlands)

    Dongen, J.E.F. van; Phaff, J.C.

    1989-01-01

    In four types of newly built single family dwellings and in apartments of a block of flats in the Netherlands, the behaviour and motivations of the occupants are studied with respect to their response to heating and ventilation, as well as their judgment on indoor air and climate variables such as t

  10. Climatic potential for passive cooling of buildings by night-time ventilation in Europe

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, H.; Heiselberg, Per

    2006-01-01

    Due to an overall trend towards less heating and more cooling demands in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising technique, particularly for commercial buildings in the moderate or cold climates of Central...

  11. Ventilation behaviour and indoor air problems in different types of newly built dwellings

    NARCIS (Netherlands)

    Dongen, J.E.F. van; Phaff, J.C.

    1989-01-01

    In four types of newly built single family dwellings and in apartments of a block of flats in the Netherlands, the behaviour and motivations of the occupants are studied with respect to their response to heating and ventilation, as well as their judgment on indoor air and climate variables such as

  12. Experimental Study of Wind-Opposed Buoyancy-Driven Natural Ventilation

    DEFF Research Database (Denmark)

    Andersen, A.; Bjerre, M.; Chen, Z. D.

    Natural ventilation driven by natural forces, i.e. wind and thermal buoyancy, is an environmentally friendly system for buildings and has been increasingly used around the world in recent years to mitigate the impact on the global environment due to the significant energy consumption by heating...

  13. A Simplified Tool for Predicting the Thermal Behavior and the Energy Saving Potential of Ventilated Windows

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Larsen, Olena Kalyanova

    2016-01-01

    windows in the early design stage. The simplified tool is developed to treat different ventilation modes: pre-heating, self-cooling and by–pass, and an operational strategy is established to determine the most energy efficient mode in each time step. Cavity air temperature and energy demand are calculated...

  14. Lung-protective ventilation in neonatology.

    Science.gov (United States)

    van Kaam, Anton

    2011-01-01

    Ventilator-induced lung injury (VILI) is considered an important risk factor in the development of bronchopulmonary dysplasia (BPD) and is primarily caused by overdistension (volutrauma) and repetitive opening and collapse (atelectrauma) of terminal lung units. Lung-protective ventilation should therefore aim to reduce tidal volumes, and recruit and stabilize atelectatic lung units (open lung ventilation strategy). This review will summarize the available evidence on lung-protective ventilation in neonatology, discussing both high-frequency ventilation (HFV) and positive pressure ventilation (PPV). It shows that HFV does not appear to have a clear benefit over PPV, although most studies failed to apply a true open lung ventilation strategy during HFV. The evidence on the optimal tidal volume, positive end-expiratory pressure and the role for lung recruitment during lung-protective PPV is extremely limited. Volume-targeted ventilation seems to be a promising mode in terms of lung protection, but more studies are needed. Due to the lack of convincing evidence, lung-protective ventilation and modes seem to be implemented in daily clinical practice at a slow pace.

  15. Numerical simulation of ventilation in blinding heading

    Institute of Scientific and Technical Information of China (English)

    CHANG De-qiang; LIU Jing-xian; CHEN Bao-zhi

    2008-01-01

    The way of ventilation in all its forms and characteristics in the blinding heading was studied. On the basis of computational fluid dynamics (CFD) the turbulence model of restrained ventilation in blinding heading was set up, and the calculation boundary condi-tions were analyzed. According to the practice application the three-dimensional flow field of ventilation in blinding heading was simulated by the computational fluid dynamics soft-ware. The characteristics of the ventilation flow field such as the temperature field zone and the flow filed zone and the rule of the flow velocity were obtained. The ventilation in blinding heading under certain circumstances was calculated and simulated for optimiza-tion. The optimal ventilation form and related parameters under given condition were ob-tained. The rule of the ventilation in blinding heading was theoretical analyzed, which pro-vided reference for the research on the process of mass transfer, the rule of hazardous substances transportation and ventilation efficiency, provided a new method for the study of reasonable and effective ventilation in blinding heading.

  16. Numerical simulation of ventilation in blinding heading

    Institute of Scientific and Technical Information of China (English)

    CHANG De-qiang; LIU Jing-xian; CHEN Bao-zhi

    2008-01-01

    The way of ventilation in all its forms and characteristics in the blinding heading was studied.On the basis of computational fluid dynamics (CFD) the turbulence model of restrained ventilation in blinding heading was set up,and the calculation boundary conditions were analyzed.According to the practice application the three-dimensional flow field of ventilation in blinding heading was simulated by the computational fluid dynamics software.The characteristics of the ventilation flow field such as the temperature field zone and the flow filed zone and the rule of the flow velocity were obtained.The ventilation in blinding heading under certain circumstances was calculated and simulated for optimization.The optimal ventilation form and related parameters under given condition were obtained.The rule of the ventilation in blinding heading was theoretical analyzed,which provided reference for the research on the process of mass transfer,the rule of hazardous substances transportation and ventilation efficiency,provided a new method for the study of reasonable and effective ventilation in blinding heading.

  17. Performance of Ductless Personalized Ventilation in Conjunction with Displacement Ventilation: Impact of Workstations Layout and Partitions

    DEFF Research Database (Denmark)

    Halvonova, Barbara; Melikov, Arsen Krikor

    2010-01-01

    The performance of a new personalized ventilation system, referred to as ductless personalized ventilation (DPV), was studied in full-scale room experiments in conjunction with displacement ventilation (DV). The idea behind DPV is to utilize clean and cool air supplied via DV. In the experiment...

  18. Repair of overheating linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Barkley, Walter; Baldwin, William; Bennett, Gloria; Bitteker, Leo; Borden, Michael; Casados, Jeff; Fitzgerald, Daniel; Gorman, Fred; Johnson, Kenneth; Kurennoy, Sergey; Martinez, Alberto; O’Hara, James; Perez, Edward; Roller, Brandon; Rybarcyk, Lawrence; Stark, Peter; Stockton, Jerry

    2004-01-01

    Los Alamos Neutron Science Center (LANSCE) is a proton accelerator that produces high energy particle beams for experiments. These beams include neutrons and protons for diverse uses including radiography, isotope production, small feature study, lattice vibrations and material science. The Drift Tube Linear Accelerator (DTL) is the first portion of a half mile long linear section of accelerator that raises the beam energy from 750 keV to 100 MeV. In its 31st year of operation (2003), the DTL experienced serious issues. The first problem was the inability to maintain resonant frequency at full power. The second problem was increased occurrences of over-temperature failure of cooling hoses. These shortcomings led to an investigation during the 2003 yearly preventative maintenance shutdown that showed evidence of excessive heating: discolored interior tank walls and coper oxide deposition in the cooling circuits. Since overheating was suspected to be caused by compromised heat transfer, improving that was the focus of the repair effort. Investigations revealed copper oxide flow inhibition and iron oxide scale build up. Acid cleaning was implemented with careful attention to protection of the base metal, selection of components to clean and minimization of exposure times. The effort has been very successful in bringing the accelerator through a complete eight month run cycle allowing an incredible array of scientific experiments to be completed this year (2003-2004). This paper will describe the systems, investigation analysis, repair, return to production and conclusion.

  19. Optimality in DNA repair.

    Science.gov (United States)

    Richard, Morgiane; Fryett, Matthew; Miller, Samantha; Booth, Ian; Grebogi, Celso; Moura, Alessandro

    2012-01-07

    DNA within cells is subject to damage from various sources. Organisms have evolved a number of mechanisms to repair DNA damage. The activity of repair enzymes carries its own risk, however, because the repair of two nearby lesions may lead to the breakup of DNA and result in cell death. We propose a mathematical theory of the damage and repair process in the important scenario where lesions are caused in bursts. We use this model to show that there is an optimum level of repair enzymes within cells which optimises the cell's response to damage. This optimal level is explained as the best trade-off between fast repair and a low probability of causing double-stranded breaks. We derive our results analytically and test them using stochastic simulations, and compare our predictions with current biological knowledge.

  20. Solar chimney for natural ventilation: A review

    Science.gov (United States)

    Dhrubo, Abir Ahsan; Alam, Chowdhury Sadid; Rahman, Md. Mustafizur; Islam, A. K. M. Sadrul

    2017-06-01

    In the 21st century the talk of the time has been proper use of renewable energy sources due to the continuous depletion of non-renewable energy sources and global warming as a result of combustion of fossil fuels. The energy situation in the 3rd world countries is even worse. The continuous industrial development in the 1st world countries is hugely responsible for global temperature increase and greenhouse gas (GHG) emissions which badly affect the countries like Bangladesh. As of April 2016, the electricity generation capacity of Bangladesh was 12,399 MW to which only 60% of the total population have access to. The shortage of electricity during the summer season makes life very difficult. Cooling of buildings requires a large quantity of energy in the summer. An alternative cooling system can reduce the dependency on electricity. This paper specially deals with a passive cooling system that reduces pressure on the electricity supply and focuses on renewable energy sources. Here a different process engineering has been discussed which incorporates Earth-to-Air Heat Exchangers with solar collector enhanced solar chimney system. In this study natural ventilation of buildings, using solar chimney system is reviewed extensively. Experimentally it has already been observed that sufficient temperature drop takes place 2-3 m within the undisturbed ground, which can work as a heat sink for ambient air if passed through and can lead to attaining comfort zone at a confined location. During peak hours of summer this kind of system may work as a very efficient cooling system and reduces extra load on electricity supply.