WorldWideScience

Sample records for renal magnetic resonance

  1. Renal relevant radiology: renal functional magnetic resonance imaging.

    Science.gov (United States)

    Ebrahimi, Behzad; Textor, Stephen C; Lerman, Lilach O

    2014-02-01

    Because of its noninvasive nature and provision of quantitative measures of a wide variety of physiologic parameters, functional magnetic resonance imaging (MRI) shows great potential for research and clinical applications. Over the past decade, application of functional MRI extended beyond detection of cerebral activity, and techniques for abdominal functional MRI evolved. Assessment of renal perfusion, glomerular filtration, interstitial diffusion, and parenchymal oxygenation turned this modality into an essential research and potentially diagnostic tool. Variations in many renal physiologic markers can be detected using functional MRI before morphologic changes become evident in anatomic magnetic resonance images. Moreover, the framework of functional MRI opened a window of opportunity to develop novel pathophysiologic markers. This article reviews applications of some well validated functional MRI techniques, including perfusion, diffusion-weighted imaging, and blood oxygen level-dependent MRI, as well as some emerging new techniques such as magnetic resonance elastography, which might evolve into clinically useful tools.

  2. Partial volume effects in dynamic contrast magnetic resonance renal studies

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, D. Rodriguez, E-mail: drodriguez@biotronics3d.co [CVSSP, Faculty of Engineering and Physical Sciences, University of Surrey (United Kingdom); Wells, K., E-mail: k.wells@surrey.ac.u [CVSSP, Faculty of Engineering and Physical Sciences, University of Surrey (United Kingdom); Diaz Montesdeoca, O., E-mail: o.diaz.montesdeoca@gmail.co [EUITT, Universidad de Las Palmas de Gran Canaria (Spain); Moran Santana, A. [EUITT, Universidad de Las Palmas de Gran Canaria (Spain); Mendichovszky, I.A., E-mail: iosifm@hotmail.co [Radiology and Physics Unit, UCL Institute of Child Health, London WC1N 1EH (United Kingdom); Gordon, I., E-mail: i.gordon@ich.ucl.ac.u [Radiology and Physics Unit, UCL Institute of Child Health, London WC1N 1EH (United Kingdom)

    2010-08-15

    This is the first study of partial volume effect in quantifying renal function on dynamic contrast enhanced magnetic resonance imaging. Dynamic image data were acquired for a cohort of 10 healthy volunteers. Following respiratory motion correction, each voxel location was assigned a mixing vector representing the 'overspilling' contributions of each tissue due to the convolution action of the imaging system's point spread function. This was used to recover the true intensities associated with each constituent tissue. Thus, non-renal contributions from liver, spleen and other surrounding tissues could be eliminated from the observed time-intensity curves derived from a typical renal cortical region of interest. This analysis produced a change in the early slope of the renal curve, which subsequently resulted in an enhanced glomerular filtration rate estimate. This effect was consistently observed in a Rutland-Patlak analysis of the time-intensity data: the volunteer cohort produced a partial volume effect corrected mean enhancement of 36% in relative glomerular filtration rate with a mean improvement of 7% in r{sup 2} fitting of the Rutland-Patlak model compared to the same analysis undertaken without partial volume effect correction. This analysis strongly supports the notion that dynamic contrast enhanced magnetic resonance imaging of kidneys is substantially affected by the partial volume effect, and that this is a significant obfuscating factor in subsequent glomerular filtration rate estimation.

  3. Magnetic Resonance Imaging as a Biomarker for Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Yan Wu

    2015-01-01

    Full Text Available As the most common neoplasm arising from the kidney, renal cell carcinoma (RCC continues to have a significant impact on global health. Conventional cross-sectional imaging has always served an important role in the staging of RCC. However, with recent advances in imaging techniques and postprocessing analysis, magnetic resonance imaging (MRI now has the capability to function as a diagnostic, therapeutic, and prognostic biomarker for RCC. For this narrative literature review, a PubMed search was conducted to collect the most relevant and impactful studies from our perspectives as urologic oncologists, radiologists, and computational imaging specialists. We seek to cover advanced MR imaging and image analysis techniques that may improve the management of patients with small renal mass or metastatic renal cell carcinoma.

  4. Hyperpolarized Renal Magnetic Resonance Imaging: Potential and Pitfalls

    Directory of Open Access Journals (Sweden)

    Christoffer eLaustsen

    2016-03-01

    Full Text Available The introduction of dissolution dynamic nuclear polarization (d-DNP technology has enabled a new paradigm for renal imaging investigations. It allows standard magnetic resonance imaging complementary renal metabolic and functional fingerprints within seconds without the use of ionizing radiation. Increasing evidence supports its utility in preclinical research in which the real-time interrogation of metabolic turnover can aid the physiological and pathophysiological metabolic and functional effects in ex vivo and in vivo models. The method has already been translated to humans, although the clinical value of this technology is unknown. In this paper, I review the potential benefits and pitfalls associated with dissolution dynamic nuclear polarization in preclinical research and its translation to renal patients.

  5. Is there a role for magnetic resonance imaging in renal trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Ku, Ja-Hyeon [Military Manpower Administration, Taejeon (Korea, Republic of); Jeon, Youn-Soo; Kim, Min-Eui; Lee, Nam-Kyu; Park, Young-Ho

    2001-06-01

    Computed tomography (CT) has been the most informative imaging method in renal trauma. Despite the good sensitivity of magnetic resonance imaging (MRI) to the presence of hematoma, edema and ischemia, MRI has not been widely studied in patients with renal trauma. The present study was initiated to evaluate the role of MRI in patients with renal trauma. Between June 1998 and September 1999, CT and MRI were prospectively performed on 12 patients who suffered from renal trauma and the results reviewed. The presence and size of perirenal hematoma could be detected by both CT and MRI. Magnetic resonance imaging could differentiate intrarenal hematoma from perirenal hematoma more accurately, and provided additional information about the hematoma as T1- and T2-weighted MRI were able to determine recent bleeding in the hematoma by regional differences in signal intensity. Magnetic resonance imaging clearly revealed renal fracture with non-viable fragment and detected focal renal laceration that was not detected on CT due to perirenal hematoma associated with renal infarction. However, although MRI had many advantages over CT, it had also major drawbacks, which were that it required longer imaging time and increased the cost. Magnetic resonance imaging may be useful in renal trauma. However, it is suggested that MRI should be limited to carefully selected patients, such as those with severe renal injury or equivocal findings on CT. (author)

  6. Diagnostic value of renal cortex-to-medulla contrast on magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Terrier, F.; Hricak, H.; Justich, E.; Dooms, G.C.; Grodd, W.

    1986-05-01

    The diagnostic value of magnetic resonance contrast between the renal cortex and renal medulla as an indicator of renal disease was retrospectively studied in 38 patients (ten patients with a variety of diseases affecting the renal parenchyma, nine with renal obstruction, four with diffusely infiltrating renal-cell carcinoma, one with renal hematoma, nine with normally functioning renal allograft, and five with renal allograft failure). Twelve normal volunteers served as controls. On spin-echo (SE) images (TR 0.5 sec, TE 28 msec), the cortex-to-medulla contrast was present in the kidneys of all the normal volunteers (19% contrast +-2% S.D.) and in all the normally functioning allografts (17% contrast +-2% S.D.). Decrease or absence of cortex-to-medulla contrast (SE image with TR 0.5 sec and TE 28 msec) was found to be a sensitive but nonspecific sign of renal disease. It occurred in renal diseases of various causes and was produced by different pathophysiologic mechanisms such as edema, scarring, and tissue replacement by neoplasm or hematoma. Of the calculated T1 and T2 relaxation times and spin density of the cortex and the medulla, the T1 changes most consistently reflected renal disease.

  7. Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment

    Institute of Scientific and Technical Information of China (English)

    Maythem Saeed; Roland Krug; Loi Do; Steven W Hetts; Mark W Wilson

    2016-01-01

    AIM: To use magnetic resonance-guided high intensity focused ultrasound(MRg-HIFU), magnetic resonance imaging(MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. METHODS: Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication(n = 24) using a 3T-MRg-HIFU(1.1 MHz frequency and 3000J-4400 J energies). T2-weighted fast spin echo(T2-W), perfusion saturation recovery gradient echo and contrast enhanced(CE) T1-weighted(T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student’s t-test was used and a P-value < 0.05 was considered statistically significant.RESULTS: Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or nonCE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images invivo(0.12-0.36 cm3 for single sonication 3000 J, 0.50-0.84 cm3, for double 3000 J, 0.75-0.78 cm3 for single 4400 J and 0.12-2.65 cm3 for double 4400J) and at postmortem(0.23-0.52 cm3, 0.25-0.82 cm3, 0.45-0.68 cm3 and 0.29-1.80 cm3, respectively) were comparable. The ablated volumes on 3000 J and 4400 J double sonication were significantly larger than single(P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively.CONCLUSION: Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.

  8. Temporal bone anomalies in the branchio-oto-renal syndrome: detailed computed tomographic and magnetic resonance imaging findings.

    NARCIS (Netherlands)

    Ceruti, S.; Stinckens, C.I.C.; Cremers, C.W.R.J.; Casselman, J.W.

    2002-01-01

    OBJECTIVE: To inventory computed tomographic and magnetic resonance imaging findings in the branchio-oto-renal (BOR) syndrome. STUDY DESIGN: A prospective computed tomographic and magnetic resonance imaging study on a family with the BOR syndrome. SETTING: Department of medical imaging and magnetic

  9. Temporal bone anomalies in the branchio-oto-renal syndrome: detailed computed tomographic and magnetic resonance imaging findings.

    NARCIS (Netherlands)

    Ceruti, S.; Stinckens, C.I.C.; Cremers, C.W.R.J.; Casselman, J.W.

    2002-01-01

    OBJECTIVE: To inventory computed tomographic and magnetic resonance imaging findings in the branchio-oto-renal (BOR) syndrome. STUDY DESIGN: A prospective computed tomographic and magnetic resonance imaging study on a family with the BOR syndrome. SETTING: Department of medical imaging and magnetic

  10. Renal damage after extracorporeal shock-wave lithotripsy detected by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Torii, Shinichiro; Machida, Toyohei; Ooishi, Yukihiko; Tashiro, Kazuya; Mochizuki, Atsushi; Yoshigoe, Fukuo

    1988-08-01

    The acute effects of extracorporeal Shock-wave lithotripsy (ESWL) on morphology of the renal parenchyma were evaluated by Magnetic Resonance Imaging (MRI) in 15 kidneys, before and immediately after (within 24 hours) ESWL in 11 cases. The renal parenchymal damages were observed by MRI as the changes of signal itensity of renal cortex and medulla, perirenal fluid, loss of corticomedullar differentiation, and other renal traumas. Loss of corticomedullar differentiation was seen in 9/11 cases and peripheral fluid of the kidney was seen in 4/11 cases. Irregular and edematous changes of renal capsula were seen in 5/11 cases. Obvious abnormal findings indicated renal trauma were not observed in this study. Several MRI findings may transient and reversible changes and the morpholigic changes detected by MRI may attributed to renal parenchymal obstruction and edema and decreasing of renal capillary flow, such as in renal contusion. It is concluded that MRI is very sensitive and the best technique to detect the effects and clinical trouble of ESWL.

  11. Magnetic Resonance Imaging (MRI) Analysis of Ischemia/Reperfusion in Experimental Acute Renal Injury.

    Science.gov (United States)

    Pohlmann, Andreas; Arakelyan, Karen; Seeliger, Erdmann; Niendorf, Thoralf

    2016-01-01

    Imbalance between renal oxygen delivery and demand in the first hours after reperfusion is suggested to be decisive in the pathophysiological chain of events leading to ischemia-induced acute kidney injury. Here we describe blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) for continuous monitoring of the deoxyhemoglobin-sensitive MR parameter T 2* in the renal cortex, outer medulla, and inner medulla of rats throughout renal ischemia/reperfusion (I/R). Changes during I/R are benchmarked against the effects of variations in the fraction of inspired oxygen (hypoxia, hyperoxia). This method may be useful for investigating renal blood oxygenation of rats in vivo under various experimental (patho)physiological conditions.

  12. Magnetic resonance angiography in potential live renal donors: a joint radiological and surgical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Subramaniam, M.; Mizzi, A.; Roditi, G. E-mail: Giles.Roditi@northglasgow.scot.nhs.ukgilesroditi@mac.com

    2004-04-01

    AIM: To assess the impact of a joint surgical and radiological audit on the accuracy of contrast-enhanced magnetic resonance angiography (MRA) reports in the evaluation of potential renal donors. MATERIALS AND METHODS: We analysed the records of live renal donors who underwent gadolinium-enhanced MRA as part of the pre-operative evaluation to assess renal vasculature between August 1999 and July 2002 when feedback from surgical findings to radiology had been available. In cases of discrepancy between MRA reports and surgical findings, studies were retrieved from the magnetic resonance imaging (MRI) workstation and subjected to detailed joint clinical and radiological review. Scan quality was assessed and sources of discrepancy were identified. RESULTS: There were 45 donors, 23 men and 22 women with a mean age of 41 years. Reported MRA findings were fully confirmed at surgery in 38 of 45 cases. These images were not analysed further. In seven donors the findings at surgery were discrepant with the radiological reports: there were four cases of 'missed' early branches and three cases of 'missed' accessory arteries. In the first year of the audit there were four discrepant cases out of 18 (22%), all of which were radiological reporting errors. The number of discrepant cases in the second year was two out of 19 cases (11%). Neither of these was a radiological reporting error. There was one 'missed' early renal artery branch in the third year of audit, which was identified on MRA review. CONCLUSION: The study highlights the importance of detecting and clearly reporting not only accessory renal arteries, but also early renal arterial branches in the pre-operative evaluation of renal donors. The accuracy of pre-operative MRA in potential renal donors is high, but radiological reporting of MRA examinations is improved through careful clinical feedback, audit and interdisciplinary co-operation.

  13. The role of magnetic resonance imaging (MRI) in refining the diagnosis of suspected fetal renal anomalies

    Institute of Scientific and Technical Information of China (English)

    Ibrahim A Abdelazim; Maha M Belal

    2012-01-01

    Objective:To detect the role of magnetic resonance imaging in refining the diagnosis of suspected fetal renal anomalies detected during screening sonography.Methods: 54 pregnant women, with suspected fetal renal anomalies detected during routine ultrasound screening, were rescanned by MRI to refine the diagnosis of the suspected renal anomalies. The pregnancy outcome was examined externally and by postnatal ultrasonography.Results:54 cases of suspected renal anomalies detected during screening sonography of 8 400 pregnant women (0.6%), were rescanned by MRI in this study. The MRI diagnosed, 29 (53.7%) cases of parenchymal renal disease, 20 (37.0%) cases of hydronephrosis, 3 (5.6%) cases of single renal cyst and 2 (3.7%) cases of megacystis + hydroureter. The amniotic fluid volume was normal in 33 (61.0%) cases, while it was decreased in 21 (39.0%) cases. Two cases of chromosomal aberration (3.7%) were detected in the studied cases. During antenatal follow up of the prenatal diagnosed cases with renal anomalies 2 cases of bilateral RA (Potter's syndrome died in utero = IUFD) and out of 52 live births 1 case of NND occurred due to bilateral MCKD with trisomy 18. In this study, when the prenatal findings were compared with the postnatal findings, the MRI was 89.5% accurate, while the prenatal ultrasound was 85% accurate in diagnosing fetal renal anomalies.Conclusion:The MRI can be used as a complementary adjunctive modality with excellent tissue contrast especially in equivocal cases or inconclusive sonographic findings.

  14. /sup 31/P nuclear magnetic resonance study of renal allograft rejection in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, J.I.; Haug, C.E.; Shanley, P.F.; Weil, R. III; Chan, L.

    1988-01-01

    Phosphorus (/sup 31/P) nuclear magnetic resonance (NMR) spectroscopy was used to serially evaluate heterotopic renal allograft rejection in the rat. Renal allografts transplanted to the groin of recipient animals were studied using a 1.89 Tesla horizontal bore magnet. The relative intracellular concentrations of phosphorus metabolites such as adenosine triphosphate and inorganic phosphate as well as intracellular pH were determined by /sup 31/P NMR on days 4, 7, 10, and 14 following transplantation across a major histocompatibility mismatch. Recipient rats chosen to be rejectors received no immunosuppression while animals chosen to be nonrejectors received cyclosporine during the first 7 days following transplantation. By day 7, all rejector rats could be distinguished from nonrejector rats by their higher relative concentration of inorganic phosphate and their lower relative concentration of adenosine triphosphate. These NMR findings correlated with histologic findings of renal infarction probably related to vascular rejection in the allografts. /sup 31/P NMR spectroscopy may have application as a noninvasive tool in the differential diagnosis of posttransplantation renal insufficiency.

  15. Extracorporeal lithotripsy renal: magnetic resonance and ultrasonography study. Rion postlitofragmentacion: estudio mediante resonancia magnetica y ecografia

    Energy Technology Data Exchange (ETDEWEB)

    Vilar, J.; Torrijo, C.; Marti-Bonmati, L.; Caballero, E.; Palop, M.C.; Sanjuan, C.

    1993-10-01

    Our aim is to identify, by means of ultrasound and magnetic resonance (MR), the renal disorders and complications produced by extracorporeal lithotripsy (ECL). Thirty candidates for ECL to treat kidney calculi were selected randomly. All the studies were carried out in duplicate, prior to and after ECL. In MR (o.5 T), coronal and axial images were obtained at different potentiations. A qualitative assessment was done with ultrasound and MR on the basis of changes in the renal morphology (size, corticomedullary definition) and the alterations in the extrarenal space (subcapsular as well as perirenal). The quantitative MR evaluation consisted of the measurement of the signal intensity in regions of interest (ROI's) located in cortex and renal medulla in T1 sequences and a great ROI including the entire renal parenchyma in T2 sequences. ECL with piezoelectric equipment shows a low incidence of short-term complications. Qualitative image disturbances appeared in 12 cases (40%), consisting of a loss of the corticomedullary definition in 4 (13.3%), extrarenal collections in 4 cases (13.3%) and alterations in the perirenal area in another 4 cases (13.3%). Quantitative changes, defined as modifications in the signal intensity in MR T2 sequences, were present in 8 cases (26.6%). None of these alterations had short-term clinical impact, and all are directly related to the intensity of the shock waves applied. Author (9 refs.)

  16. Efficacy of magnetic resonance urography in detecting renal scars in children with vesicoureteral reflux.

    Science.gov (United States)

    Koçyiğit, Ali; Yüksel, Selçuk; Bayram, Recep; Yılmaz, İsmail; Karabulut, Nevzat

    2014-07-01

    The detection of renal scars is of paramount importance for optimal clinical management of patients with urinary tract infection (UTI) and vesicoureteral reflux (VUR). The aim of our study was to compare the efficacy of unenhanced magnetic resonance urography (MRU) and Tc-99(m) dimercaptosuccinic acid (Tc-DMSA) scintigraphy to dectect renal scars. Unenhanced MRU and Tc-DMSA scintigraphy were performed in 49 children (10 boys, 39 girls; mean age 7.4 ± 4.2 years, range 1-15 years) with documented VUR. MR imaging scans were obtained within 7 days after voiding cystourethrogram (VCUG) and Tc-DMSA scintigraphy. The diagnostic performance of MRU in renal scar detection was calculated relative to that of the Tc-DMSA scan. The renal scar detection rate of Tc-DMSA scintigraphy and unenhanced MRU in kidneys with VUR was 32.4 and 25.9%, respectively. The sensitivity and specificity of MRU in the detection of renal scars was 80 and 82.6% in kidneys with VUR, respectively. There was no statistically significant difference in lesion detection between MRU and Tc-DMSA scintigraphy (P > 0.05). MRU and Tc-DMSA scintigraphy showed good agreement (κ = 0.60). Unenhanced MRU is a robust technique for the morphologic assessment of the urinary system and detection of renal scars. The lack of radiation and contrast material makes this technique a much safer alternative to scintigraphy in children with VUR, particularly in those who require follow-up scanning and, consequently, considerable radiation exposure.

  17. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole;

    2016-01-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention...... with the microscopic examinations revealing of fibrotic scar tissue formation in the peripheral zone of the cryolesion. On T2 magnetic resonance imaging sequences, a thin hypointense rim surrounded the cryolesion, separating it from the adjacent renal parenchyma. Microscopic examinations revealed hemorrhage and later...... of coagulative necrosis 1 week after laparoscopic-assisted cryoablation, which was partially replaced by fibrotic scar tissue 4 weeks following laparoscopic-assisted cryoablation. Both computed tomography perfusion and magnetic resonance imaging found the renal collecting system to be involved at all 3 stages...

  18. Dynamic magnetic resonance imaging in the assessment of chronic medical nephropathies with impaired renal function

    Energy Technology Data Exchange (ETDEWEB)

    Dalla-Palma, L.; Pozzi-Mucelli, R.S.; Cova, M.; Meduri, S. [Dept. of Radiology, University of Trieste (Italy); Panzetta, G.; Galli, G. [Hemodialysis Service, Ospedale Maggiore, Trieste (Italy)

    2000-02-01

    We examined the value of dynamic magnetic resonance imaging (MRI) in chronic renal disease with renal insufficiency. In 33 consecutive patients (21 vascular nephropathy, 12 glomerular nephropathy) MRI was performed using a 1.5-T unit and a body coil, with SE T1-weighted (TR/TE = 600/19 ms) and dynamic TFFE T1-weighted sequences (TR/TE = 12/5 ms, flip angle = 25 ) after manual bolus injection (via a cubital vein) of 0.1 mmol/kg Gd-DTPA-BMA. Morphological evaluation was performed in unblinded fashion by three radiologists, evaluating renal size, cortical thickness, and corticomedullary differentiation. Functional analysis was performed by one reviewer. Time-signal intensity curves, peak intensity value (P), time to peak intensity (T), and the P/T ratio were obtained at the cortex, medulla, and pyelocaliceal system of each kidney. The relationship of these parameters to serum creatinine and with creatinine clearance was investigated. A good correlation between morphological features of the kidneys and serum creatinine values was found. Morphological findings could not distinguish between vascular and glomerular nephropathies. A statistically significant correlation (P <0.01) between cortical P, cortical P/T, medullary P, and serum creatinine and creatinine clearance was found. A significant correlation (P <0.01) was also found between cortical T, medullary P/T, T of the excretory system, and creatinine clearance. The cortical T value was significantly higher (P <0.01) in vascular nephropathy than in glomerular nephropathy. Thus in patients with chronic renal failure dynamic MRI shows both morphological and functional changes. Morphological changes are correlated with the degree of renal insufficiency and not with the type of nephropathy; the functional changes seem to differ in vascular from glomerular nephropathies. (orig.)

  19. Role of magnetic resonance urography in diagnosis of duplex renal system: Our initial experience at a tertiary care institute

    Directory of Open Access Journals (Sweden)

    Milind P Joshi

    2009-01-01

    Full Text Available Aim: To determine diagnostic value of magnetic resonance urography in cases of duplex renal system. Method: Twenty cases between five month to nine years with suspected or known duplex renal system were evaluated by ultrasound (USG, micturating cystourethrography (MCU, intravenous urography (IVU and magnetic resonance urography (MRU. The findings of these diagnostic imaging studies were then compared with each other and against the results of final diagnosis established at surgery. Results: Duplex renal system could be identified in two of these cases on USG, was diagnosed in four in IVU and could be diagnosed in all cases with MRU. Conclusion: MRU is superior and far accurate than IVU, MCU and USG in diagnosing duplex renal system.

  20. Role of magnetic resonance urography in diagnosis of duplex renal system: Our initial experience at a tertiary care institute

    Science.gov (United States)

    Joshi, Milind P.; Shah, Heemanshi S.; Parelkar, Sandesh V.; Agrawal, Amit A.; Sanghvi, Beejal

    2009-01-01

    Aim: To determine diagnostic value of magnetic resonance urography in cases of duplex renal system. Method: Twenty cases between five month to nine years with suspected or known duplex renal system were evaluated by ultrasound (USG), micturating cystourethrography (MCU), intravenous urography (IVU) and magnetic resonance urography (MRU). The findings of these diagnostic imaging studies were then compared with each other and against the results of final diagnosis established at surgery. Results: Duplex renal system could be identified in two of these cases on USG, was diagnosed in four in IVU and could be diagnosed in all cases with MRU. Conclusion: MRU is superior and far accurate than IVU, MCU and USG in diagnosing duplex renal system. PMID:19468429

  1. Unenhanced respiratory-navigated NATIVE(®) TrueFISP magnetic resonance angiography in the evaluation of renal arteries: Comparison with contrast-enhanced magnetic resonance angiography.

    Science.gov (United States)

    Değirmenci, B; Kara, M; Kıdır, V; İnal, S; Sezer, T; Umul, A; Orhan, H; Çelik, A O; Demirtaş, H; Yilmaz, Ö

    2017-02-01

    To compare unenhanced three-dimensional (3D) NATIVE(®) true fast imaging with steady-state precession (TrueFISP) magnetic resonance (MR) angiography with the more conventional MR angiography technique obtained after intravenous administration of a gadolinium chelate in the evaluation of renal arteries and their branches in patients with suspected renal artery stenosis. A total of 39 patients (25 men, 14 women) with a mean age of 51.4±17.5years (SD) (range: 10-82years) were included in the study. All patients with suspected renal artery stenosis underwent unenhanced 3D NATIVE(®) TrueFISP MR angiography and contrast-enhanced MR angiography. The two MR angiography methods were compared by two independent readers for image quality using a four-point scale, diagnostic performance and grading of renal artery stenosis on a total of 78 renal arteries. For both readers image quality of unenhanced 3D NATIVE(®) TrueFISP MR angiography (3.12 to 3.63) was greater than that of contrast-enhanced MR angiography (1.94 to 2.71) for renal artery ostium-trunk and the left renal artery segmental branches. The sensitivity of 3D NATIVE(®) TrueFISP MR angiography for the diagnosis of renal artery stenosis was 100% for both readers for the right renal artery and 66% and 80% for the left renal artery for reader 1 and reader 2, respectively. Agreement between 3D NATIVE(®) TrueFISP MR angiography and CE-MR angiography was 95% (74/78) for reader 1 and 92% (72/78) for reader 2. Unenhanced NATIVE(®) TrueFISP magnetic resonance angiography can play an additional role in the evaluation of renal arteries in patients with hypertension, especially in subjects at risk of nephrogenic systemic fibrosis. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  2. Non-contrast magnetic resonance angiography in renal transplantation and renal donation

    DEFF Research Database (Denmark)

    Blankholm, Anne Dorte

    2015-01-01

    examination of living kidney donors. We compared CTA to an extensive MRI protocol without the use of contrast agents, including NCMRA, and to observations from living donor nephrectomy, which served as the reference standard. We concluded that an optimised MRI protocol without contrast agents could...... be substituted for CTA for preoperative vessel assessment in living kidney donors.......Renal transplantation is the treatment of choice in cases of severe renal disease. The majority of candidates for kidney transplantation have arteriosclerosis to some extent; thus, preoperative imaging of the vessels is needed. Different imaging modalities are available and are used...

  3. Efficacy of Magnetic Resonance urography in detecting crossing renal vessels in children with ureteropelvic junction obstruction.

    Science.gov (United States)

    Pavicevic, Polina K; Saranovic, Djordjije Z; Mandic, Marija J; Vukadinovic, Vojkan M; Djordjevic, Miroslav Lj; Radojicic, Zoran I; Petronic, Ivana; Cirovic, Dragana; Nikolic, Dejan

    2015-01-01

    An aberrant or accessory crossing renal vessel (CV) leading to the lower pole of the kidney is the most common extrinsic cause of uretero pelvic obstruction(UPJ) obstruction in a child and young adolescent.There is still controversy regarding there functional significance in obstruction Preoperative identification of such vessels may influence surgical management. First aim is to determine the value of magnetic resonance (MR) urography in detecting crossing vessels in children with UPJ obstruction,comparing the data with postoperative findings and the second one is to evaluate morphologic and functional parameters in these hydronephrotic kidneys. Between June 2009 and December 2012 we retrospectively reviewed MR urography records of one hundred and nine children with unilateral hydronephrosis at the University Children's Hospital. 68 (62.4%) were male and 41 (37.6%) were female,median age was 6.5 ± 5.7. Of the total number of patients, 30 (27%) underwent pyeloplasty, while 79 (72.5%) did not. The age at surgery ranged from 0.3 to 18 years (median 6.6 years). The indication for surgery was based on standard criteria (obstructed renal transit time with or without altered renal function of vDRF MRU, there was no crossing vessel in 21 kidneys, confirmed at surgery in 18. A crossing vessel was detected with MRU in 9 kidneys and confirmed at surgery in 6. Thus, the sensitivity of MRU was 66.7%, the specificity was 85.7%, the positive predictive value was 66.7%, the negative predictive value was 85.7% and the accuracy was 80%. There was no statistically significant difference in the detection of crossing vessels between MR urography and surgery (p = 0.004 and p MRU and surgery showed good agreement (κ = 0.524). Based on our results we suggest that MR urography is a reliable and safe diagnostic tool to determine crossing vessels in selected children with UPJ obstruction. Thus, MRU can substitute for other imaging modalities and provide detailed information about the

  4. Determinations of renal cortical and medullary oxygenation using BOLD Magnetic Resonance Imaging and selective diuretics

    Science.gov (United States)

    Warner, Lizette; Glockner, James F.; Woollard, John; Textor, Stephen C.; Romero, Juan C.; Lerman, Lilach O.

    2010-01-01

    Objective This study was undertaken to test the hypothesis that blood O2 level dependent magnetic resonance imaging (BOLD MRI) can detect changes in cortical proximal tubule (PT) and medullary thick ascending limb of Henle (TAL) oxygenation consequent to successive administration of furosemide and acetazolamide (Az). Assessment of PT and TAL function could be useful to monitor renal disease states in vivo. Therefore, the adjunct use of diuretics that inhibit Na+ reabsorption selectively in PT and TAL, Az and furosemide, respectively, may help discern tubular function by using BOLD MRI to detect changes in tissue oxygenation. Material and Methods BOLD MRI signal R2* (inversely related to oxygenation) and tissue oxygenation with intrarenal O2 probes were measured in pigs that received either furosemide (0.5mg/kg) or Az (15mg/kg) alone, Az sequentially after furosemide (n=6 each, 15-minute intervals), or only saline vehicle (n=3). Results R2* decreased in the cortex of Az-treated and medulla of furosemide-treated kidneys, corresponding to an increase in their tissue O2 assessed with probes. However, BOLD MRI also showed decreased cortical R2* following furosemide that was additive to the Az-induced decrease. Az administration, both alone and after furosemide, also decreased renal blood flow (−26±3.5 and −29.2±3%, respectively, p<0.01). Conclusion These results suggest that an increase in medullary and cortical tissue O2 elicited by selective diuretics is detectable by BOLD MRI, but may be complicated by hemodynamic effects of the drugs. Therefore, the BOLD MRI signal may reflect functional changes additional to oxygenation, and needs to be interpreted cautiously. PMID:20856128

  5. Fetal and Postnatal Magnetic Resonance Imaging of Unilateral Cystic Renal Dysplasia in a Neonate with Tuberous Sclerosis

    Directory of Open Access Journals (Sweden)

    Vineet Tyagi

    2016-10-01

    Full Text Available Tuberous sclerosis (TS is an autosomal dominant condition associated with mutations in the TSC1 and/or TSC2 genes. Clinical manifestations are multisystemic, and they often include lesions in the brain, skin, heart, kidneys, and bones. TSC2 gene mutations can be seen concomitantly with autosomal dominant polycystic kidney disease gene mutations. We present a case of a fetus with prenatal diagnosis of TS that had unique asymmetrical distribution of renal cystic disease. We describe the extensive work up with both fetal and neonatal magnetic resonance imaging with correlating images of the unilateral polycystic renal disease in addition to typical TS brain findings.

  6. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole

    2017-01-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention......, each animal was randomized to a postoperative follow-up period of 1, 2, or 4 weeks, after which computed tomography perfusion and magnetic resonance imaging scans were performed. Immediately after imaging, open bilateral nephrectomy was performed allowing for histopathological examination...... of the cryolesions. On computed tomography perfusion and magnetic resonance imaging examinations, rim enhancement was observed in the transition zone of the cryolesion 1week after laparoscopic-assisted cryoablation. This rim enhancement was found to subside after 2 and 4 weeks of follow-up, which was consistent...

  7. Value of Apparent Diffusion Coefficient(ADC) of Diffusion eighted Magnetic Resonance Imaging in Common Renal Disease Diagnosis

    Institute of Scientific and Technical Information of China (English)

    Yuelang Zhang; Xingwang Sun; Guangnan Quan; Yongqian Qiang; Chenxia Li

    2008-01-01

    Objective:To find the value of the apparent diffusion coefficient (ADC) of diffusion weighted magnetic resonance imaging of common renal diseases. Methods: There were 30 healthy subjects and 81 patients with renal lesions (56 cases of renal carcinoma, 18 lesions of 12 cases of renal angiomyolipoma, and 21 lesions of 13 cases of renal cysts). Conventional magnetic resonance imaging and diffusion weighted magnetic resonance imaging were carded out. We measured the average ADC value of the renal lesions and normal kidneys. ADC maps from different b values were generated by a statistical package. Results: The ADC values of normal kidneys with three different motion-probing gradients(b=500, 800, 1000 sec/mm2) were 2.78±0.14×10-3mm2s-1,2.45±0.13×10-3mm2s-1, 2.13±0.14×10-3mm2s-1, respectively. The ADC values of renal cell carcinoma with three different motion-probing gradients(b=500, 800, 1008 sec/mm2) were 1.63±0.14×10-3mm2s-1, 1.31±0.18×10-3mm2s-1, 1.07±0.15-310-3mm2s-1, respectively. Among the renal cell carcinoma, the ADC value of clear cell type were 1.67±0.09×10-3mm2s-1, 1.36±0.13×10-3mm2s-1, 1.15±0.14×10-3mm2s-1,respectively; the ADC values of granular cell type were 1.59±0.19×10-3mm2s-1, 1.25±0.22×10-3mm2s-1, 0.97±0.12×10-3mm2s-1, respectively. The ADC values of renal angiomyolipoma with three different motion-probing gradients(b=500, 800, 1008 sec/mm2) were 0.88±0.08×10-3mm2s-1, 0.63±0.07×10-3mm2s-1, 0.43±0.04×10-3mm2s-1, respectively. The ADC values of renal cystic lesions with three different motion-probing gradients(b=500, 800, 1000 sec/mm2) were 3.73±0.18×10-3mm2s-1, 3.44±0.13×10-3mm2s-1, 3.09±0.21×10-3mm2s-1, respectively. Statistically significant differences exists between the ADC values of normal kidney, renal carcinomas, renal angiomyolipomas and renal cysts when the b value is the same. Among the different cell types of renal carcinomas, the ADC value of granular cell carcinoma is lower than that of clear cell

  8. Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology.

    Science.gov (United States)

    Niendorf, Thoralf; Pohlmann, Andreas; Reimann, Henning M; Waiczies, Helmar; Peper, Eva; Huelnhagen, Till; Seeliger, Erdmann; Schreiber, Adrian; Kettritz, Ralph; Strobel, Klaus; Ku, Min-Chi; Waiczies, Sonia

    2015-01-01

    Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g., by supporting MR microscopy) and making data acquisition more efficient (e.g., by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine, and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular, and renal disease will be discussed.

  9. Advancing Cardiovascular, Neurovascular and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology

    Directory of Open Access Journals (Sweden)

    Thoralf eNiendorf

    2015-11-01

    Full Text Available Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF coils in small animal MR as a means of boosting image quality (e.g. by supporting MR microscopy and making data acquisition more efficient (e.g. by reducing measuring time; both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (biomedical imaging, molecular medicine and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (pathophysiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular and renal disease will be discussed.

  10. Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology

    Science.gov (United States)

    Niendorf, Thoralf; Pohlmann, Andreas; Reimann, Henning M.; Waiczies, Helmar; Peper, Eva; Huelnhagen, Till; Seeliger, Erdmann; Schreiber, Adrian; Kettritz, Ralph; Strobel, Klaus; Ku, Min-Chi; Waiczies, Sonia

    2015-01-01

    Research in pathologies of the brain, heart and kidney have gained immensely from the plethora of studies that have helped shape new methods in magnetic resonance (MR) for characterizing preclinical disease models. Methodical probing into preclinical animal models by MR is invaluable since it allows a careful interpretation and extrapolation of data derived from these models to human disease. In this review we will focus on the applications of cryogenic radiofrequency (RF) coils in small animal MR as a means of boosting image quality (e.g., by supporting MR microscopy) and making data acquisition more efficient (e.g., by reducing measuring time); both being important constituents for thorough investigational studies on animal models of disease. This review attempts to make the (bio)medical imaging, molecular medicine, and pharmaceutical communities aware of this productive ferment and its outstanding significance for anatomical and functional MR in small rodents. The goal is to inspire a more intense interdisciplinary collaboration across the fields to further advance and progress non-invasive MR methods that ultimately support thorough (patho)physiological characterization of animal disease models. In this review, current and potential future applications for the RF coil technology in cardiovascular, neurovascular, and renal disease will be discussed. PMID:26617515

  11. Multiparametric magnetic resonance imaging for the differentiation of low and high grade clear cell renal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Tricaud, E.; Lasserre, A.S.; Petitpierre, F.; Le Bras, Y.; Bouzgarrou, M.; Grenier, N. [Pellegrin Hospital, Department of Radiology, Bordeaux (France); Bernhard, J.C. [Pellegrin Hospital, Department of Urology, Bordeaux (France); Yacoub, M. [Pellegrin Hospital, Department of Pathology, Bordeaux (France); Ravaud, A. [Saint-Andre Hospital, Department of Oncology, Bordeaux (France)

    2015-01-15

    To retrospectively evaluate the ability of magnetic resonance (MR) imaging to differentiate low from high Fuhrman grade renal cell carcinoma (RCC). MR images from 80 consecutive pathologically proven RCC (57 clear cell, 16 papillary and 7 chromophobe) were evaluated. Double-echo chemical shift, dynamic contrast-enhanced T1- and T2-weighted images and apparent diffusion coefficient (ADC) maps were reviewed independently. Signal intensity index (SII), tumour-to-spleen SI ratio (TSR), ADC ratio, wash-in (WiI) and wash-out indices (WoI) between different phases were calculated and compared to pathological grade and size. The Fuhrman scoring system was used. Low grade (score ≤2) and high grade (score ≥3) tumours were compared using univariate and multivariate analyses. No associations between grade and imaging factors were found for papillary and chromophobe RCCs. For clear cell RCCs, there was a significant association between the grade and parenchymal WiI (WiI2) (P = 0.02) or ADCr (P = 0.03). A significant association between tumour grade and size (P = 0.01), WiI2 (P = 0.02) and ADCr (P = 0.05) remained in multivariate analysis. Multiparametric MRI can be used to accurately differentiate low Fuhrman grade clear cell RCC from high grade. High Fuhrman grade (≥3) RCCs were larger, had lower parenchymal wash-in indices and lower ADC ratios than low grade. (orig.)

  12. Quantitative assessment of renal function with magnetic resonance imaging; Quantitative Erfassung der renalen Funktion mit der Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, S.O.; Bock, M.; Aumann, S.; Essig, M.; Floemer, F.; Knopp, M.V.; Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Abt. Radiologische Diagnostik und Therapie; Just, A. [Heidelberg Univ. (Germany). 1. Physiologisches Inst.

    2000-10-01

    Aim. To show the potential of various methods in magnetic resonance imaging for the evaluation of renal function. Material and Methods. A combined assessment of renal morphology, renal hemodynamics and function is proposed. Various techniques are explained, including multiphasic 3D gadolinium MR angiography, MR phase-contrast flow measurements, quantitative perfusion measurements with intravascular contrast agents, and MR renography and MR urography. The use of these techniques is demonstrated for renovascular diseases. Results. The combined use of these techniques allows renal artery stenosis to be accurately detected and evaluation of renal blood flow, perfusion, glomerular filtration rate, and renal excretion. Based on true quantitative parameters, the hemodynamic and functional significance of the stenosis can be assessed. Renovascular diseases can be differentiated from renoparenchymal disease. Conclusion. For the assessment of renal function, functional magnetic resonance imaging techniques are an important alternative to nuclear medicine. The predictive value regarding the effect of revascularization is currently under investigation. (orig.) [German] Fragestellung. Verschiedene Methoden der Magnetresonanztomographie zur quantitativen Erfassung der Nierenfunktion sollen aufgezeigt werden. Methodik. Es werden MR-Techniken zur kombinierten Beurteilung der renalen Morphologie, Haemodynamik und Funktion der Niere vorgestellt. Zur Anwendung kommen hierbei die multiphasische 3-D-Gadolinium-MR-Angiographie, die MR-Phasenkontrastflussmessung, die quantitative Perfusionsmessung mit intravasalen Kontrastmitteln sowie die MR-Renographie/MR-Urographie. Die Methoden werden exemplarisch am Beispiel renovaskulaerer Erkrankungen demonstriert. Ergebnisse. Mit den vorgestellten Methoden lassen sich Nierenarterienstenosen akkurat detektieren sowie Aenderungen des renalen Blutflusses, der Nierenperfusion, der Filtrationsleistung sowie der renalen Ausscheidung erfassen. Auf der

  13. Detailing the relation between renal T2* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements.

    Science.gov (United States)

    Pohlmann, Andreas; Arakelyan, Karen; Hentschel, Jan; Cantow, Kathleen; Flemming, Bert; Ladwig, Mechthild; Waiczies, Sonia; Seeliger, Erdmann; Niendorf, Thoralf

    2014-08-01

    This study was designed to detail the relation between renal T2* and renal tissue pO2 using an integrated approach that combines parametric magnetic resonance imaging (MRI) and quantitative physiological measurements (MR-PHYSIOL). Experiments were performed in 21 male Wistar rats. In vivo modulation of renal hemodynamics and oxygenation was achieved by brief periods of aortic occlusion, hypoxia, and hyperoxia. Renal perfusion pressure (RPP), renal blood flow (RBF), local cortical and medullary tissue pO2, and blood flux were simultaneously recorded together with T2*, T2 mapping, and magnetic resonance-based kidney size measurements (MR-PHYSIOL). Magnetic resonance imaging was carried out on a 9.4-T small-animal magnetic resonance system. Relative changes in the invasive quantitative parameters were correlated with relative changes in the parameters derived from MRI using Spearman analysis and Pearson analysis. Changes in T2* qualitatively reflected tissue pO2 changes induced by the interventions. T2* versus pO2 Spearman rank correlations were significant for all interventions, yet quantitative translation of T2*/pO2 correlations obtained for one intervention to another intervention proved not appropriate. The closest T2*/pO2 correlation was found for hypoxia and recovery. The interlayer comparison revealed closest T2*/pO2 correlations for the outer medulla and showed that extrapolation of results obtained for one renal layer to other renal layers must be made with due caution. For T2* to RBF relation, significant Spearman correlations were deduced for all renal layers and for all interventions. T2*/RBF correlations for the cortex and outer medulla were even superior to those between T2* and tissue pO2. The closest T2*/RBF correlation occurred during hypoxia and recovery. Close correlations were observed between T2* and kidney size during hypoxia and recovery and for occlusion and recovery. In both cases, kidney size correlated well with renal vascular conductance

  14. Noncontrast-Enhanced Magnetic Resonance Versus Computed Tomography Angiography in Preoperative Evaluation of Potential Living Renal Donors

    DEFF Research Database (Denmark)

    Blankholm, Anne Dorte; Pedersen, Bodil G; Østrat, Ernst Ø

    2015-01-01

    RATIONALE AND OBJECTIVES: Living renal donors undergo an extensive examination program. These examinations should be as safe, gentle, and patient friendly as possible. To compare computed tomography angiography (CTA) and an extensive magnetic resonance imaging (MRI) protocol without contrast agents...... to observations from nephrectomy in living renal donors and to evaluate whether noncontrast-enhanced MRI can replace CTA for vessel assessment in living renal donors. MATERIAL AND METHODS: CTA and MRI results were compared to observations from nephrectomy, which served as the reference standard. Fifty......-one potential kidney donors underwent imaging, and 31 donated a kidney. Comparisons in sensitivity, specificity, and accuracy were made with respect to the number of arteries, early branching, and the number of veins. Agreement was assessed using Cohen's kappa. The exact McNemar's test was used to test...

  15. Utility and limitations of 3-Tesla diffusion-weighted magnetic resonance imaging for differentiation of renal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Sevcenco, S., E-mail: sabina.sevcenco@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Heinz-Peer, G., E-mail: gertraud.heinz-peer@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Ponhold, L., E-mail: lothar.ponhold@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Javor, D., E-mail: domagoj.javor@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Kuehhas, F.E., E-mail: frenklin.kuehhas@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Klingler, H.C., E-mail: christoph.klingler@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Remzi, M., E-mail: mesut.remzi@gmx.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Weibl, P., E-mail: peter.weibl@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Shariat, S.F., E-mail: sfshariat@gmail.com [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Baltzer, P.A., E-mail: pascal.baltzer@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria)

    2014-06-15

    Objective: To investigate utility and limitations of 3-Tesla diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiation of benign versus malignant renal lesions and renal cell carcinoma (RCC) subtypes. Materials and methods: Sixty patients with 71 renal lesions underwent 3 Tesla DW-MRI of the kidney before diagnostic tissue confirmation. The images were retrospectively evaluated blinded to histology. Single-shot echo-planar imaging was used as the DW imaging technique. Apparent diffusion coefficient (ADC) values were measured and compared with histopathological characteristics. Results: There were 54 malignant and 17 benign lesions, 46 lesions being small renal masses ≤4 cm. Papillary RCC lesions had lower ADC values (p = 0.029) than other RCC subtypes (clear cell or chromophobe). Diagnostic accuracy of DW-MRI for differentiation of papillary from non-papillary RCC was 70.3% resulting in a sensitivity and specificity of 64.3% (95% CI, 35.1–87.2) and 77.1 (95% CI, 59.9–89.6%). Accuracy increased to 83.7% in small renal masses (≤4 cm diameter) and sensitivity and specificity were 75.0% and 88.5%, respectively. The ADC values did not differ significantly between benign and malignant renal lesions (p = 0.45). Conclusions: DW-MRI seems to distinguish between papillary and other subtypes of RCCs especially in small renal masses but could not differentiate between benign and malignant renal lesions. Therefore, the use of DW-MRI for preoperative differentiation of renal lesions is limited.

  16. Assessment of Renal Hemodynamics and Oxygenation by Simultaneous Magnetic Resonance Imaging (MRI) and Quantitative Invasive Physiological Measurements.

    Science.gov (United States)

    Cantow, Kathleen; Arakelyan, Karen; Seeliger, Erdmann; Niendorf, Thoralf; Pohlmann, Andreas

    2016-01-01

    In vivo assessment of renal perfusion and oxygenation under (patho)physiological conditions by means of noninvasive diagnostic imaging is conceptually appealing. Blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI) and quantitative parametric mapping of the magnetic resonance (MR) relaxation times T 2* and T 2 are thought to provide surrogates of renal tissue oxygenation. The validity and efficacy of this technique for quantitative characterization of local tissue oxygenation and its changes under different functional conditions have not been systematically examined yet and remain to be established. For this purpose, the development of an integrative multimodality approaches is essential. Here we describe an integrated hybrid approach (MR-PHYSIOL) that combines established quantitative physiological measurements with T 2* (T 2) mapping and MR-based kidney size measurements. Standardized reversible (patho)physiologically relevant interventions, such as brief periods of aortic occlusion, hypoxia, and hyperoxia, are used for detailing the relation between the MR-PHYSIOL parameters, in particular between renal T 2* and tissue oxygenation.

  17. Noncontrast-Enhanced Magnetic Resonance Versus Computed Tomography Angiography in Preoperative Evaluation of Potential Living Renal Donors.

    Science.gov (United States)

    Blankholm, Anne Dorte; Pedersen, Bodil G; Østrat, Ernst Ø; Andersen, Gratien; Stausbøl-Grøn, Brian; Laustsen, Susse; Ringgaard, Steffen

    2015-11-01

    Living renal donors undergo an extensive examination program. These examinations should be as safe, gentle, and patient friendly as possible. To compare computed tomography angiography (CTA) and an extensive magnetic resonance imaging (MRI) protocol without contrast agents to observations from nephrectomy in living renal donors and to evaluate whether noncontrast-enhanced MRI can replace CTA for vessel assessment in living renal donors. CTA and MRI results were compared to observations from nephrectomy, which served as the reference standard. Fifty-one potential kidney donors underwent imaging, and 31 donated a kidney. Comparisons in sensitivity, specificity, and accuracy were made with respect to the number of arteries, early branching, and the number of veins. Agreement was assessed using Cohen's kappa. The exact McNemar's test was used to test for statistically significant differences. In the assessment of more than one renal artery, the sensitivity and specificity of MRI and CTA were high and in perfect agreement compared to observations from surgery. The results for both MRI and CTA were as follows: (sensitivity 100%/specificity100%/accuracy 100%/Kappa = 1/P = 1). When comparing the ability to test for early branching we found, MRI: (sensitivity 33%/specificity 100%/accuracy 87%/Kappa = 0.45/P = 1) and CTA: (sensitivity 50%/specificity 100%/accuracy 90%/Kappa = 0.62/P = 1). When used to depict supernumerary veins, we found MRI: (sensitivity60%/specifivity100%/accuracy 93%/Kappa = 0.72/P = 1), whereas CTA showed: (sensitivity 40%/specificity 96%/accuracy 87% Kappa = 0.43/P = 1). In conclusion, an optimized MRI protocol that includes noncontrast-enhanced magnetic resonance angiography can be substituted for CTA for preoperative assessment of the renal vessels before living donor nephrectomy. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  18. Single ectopic ureteral orifice with bilateral duplicated renal collecting systems in an adult girl: Diagnosis by magnetic resonance urography.

    Science.gov (United States)

    Tang, Min; Wang, Quanrongzi; Liu, Bianjiang; Li, Jie; Lu, Qiang; Song, Ninghong; Wang, Zengjun; Zhang, Wei

    2015-01-01

    Renal duplication accompanied by ureteral ectopia is an uncommon urinary congenital abnormality. We report the case of a 21-year-old girl who suffered from lifelong continuous urinary leakage. She was finally diagnosed with bilateral duplicated collecting systems complicated with right ectopic ureteral orifice - an extremely rare case. The patient underwent ureteric re-implantation for the ectopic side, and her urinary incontinence ceased soon thereafter. In this case, traditional imaging failed to show the exact insertion of an ectopic ureter. However, magnetic resonance urography combined with retrograde intubation radiography successfully depicted the point of ureteric insertion, which may make the diagnostic process accurate and efficient.

  19. Renal dysplasia with single system ectopic ureter: Diagnosis using magnetic resonance urography and management with laparoscopic nephroureterectomy in pediatric age

    Science.gov (United States)

    Joshi, Milind; Parelkar, Sandesh; Shah, Heemanshi

    2009-01-01

    Single system ureteral ectopia and associated congenital dysplastic kidney is surgically curable etiology of incontinence with other wise normal pattern of voiding in female child. We share our experience of eight cases in last one year and its management with laparoscopic nephroureterectomy at a tertiary care hospital in India which is one of the largest series in such a short duration of this rare anomaly. Materials and Methods: Patients presented with clinical features of continence with otherwise normal pattern of voiding were clinically examined and investigated by ultrasound (USG), nuclear renal scan, magnetic resonance urography (MRU). Laparoscopic nephroureterectomy was done in all the eight cases and renal dysplasia was confirmed on histological examination. Results: All the patients were females in the age group of five months to five years. USG detected the renal dysplasia in three out of eight cases; however, it could not detect the course of the ectopic ureter in any of the cases. MRU picked up the dysplastic moieties and their location as well as functional status and also depicted the course of the ectopic ureter opening into the vaginal wall in all the eight cases. Laparoscopic nephroureterectomy was done in all the cases and patients were cured off their symptoms. Conclusion: Single system ectopic ureter associated with congenital renal dysplasia is exceedingly rare. MRU is definitely the better investigation for the diagnosis of this condition as compared to the conventional radiological investigations. Laparoscopic nephroureterectomy is a very good procedure for the management of these cases. PMID:19955670

  20. Combined magnetic resonance urography and targeted helical CT in patients with renal colic: a new approach to reduce delivered dose.

    Science.gov (United States)

    Blandino, Alfredo; Minutoli, Fabio; Scribano, Emanuele; Vinci, Sergio; Magno, Carlo; Pergolizzi, Stefano; Settineri, Nicola; Pandolfo, Ignazio; Gaeta, Michele

    2004-08-01

    To determine whether magnetic resonance urography (MRU), obtained before helical computed tomography (CT) in patients with acute renal colic, can help delimit the obstructed area to be subsequently examined by a targeted CT scan, thus reducing the dose of radiation. Patients (51) with symptoms of acute renal colic underwent MRU and a total urinary tract helical CT. CT images from the 5 cm below the level of ureteral obstruction as demonstrated by MRU were selected out. Combined interpretation of MRU and selected CT images constituted protocol A. Protocol B consisted of the entire unenhanced helical CT of the urinary tract. The two protocols were compared regarding the following points: 1) sensitivity in diagnosing the presence of obstructing urinary stones, and 2) the delivered radiation dose. Protocol A and protocol B had, respectively, 98% and 100% sensitivity in demonstrating ureteral stone as a cause of renal colic. Estimated average dose calculated from phantom study was 0.52 mSv for protocol A and 2.83 mSv for protocol B. Therefore, the effective radiation dose was 5.4 times lower in protocol A compared to protocol B. Combined MRU and short helical CT has a high sensitivity in detecting ureteral calculi with a reduced radiation dose. Copyright 2004 Wiley-Liss, Inc.

  1. Suture Granuloma Mimicking Renal Cell Carcinoma: Magnetic Resonance Imaging (MRI and Pathologic Correlation

    Directory of Open Access Journals (Sweden)

    İbrahim İlker Öz

    2014-11-01

    Full Text Available Solid renal masses are generally distinguished with contrast enhancement and intratumoral fatty foci by radiological examinations. The present of enhancement is most important criteria for diagnosis of malignant lesions. Generally, a contrast enhanced solid mass in kidney is accepted as a neoplasm. Foreign body granuloma is an extraordinary cause of enhanced solid renal mass. This case of a renal suture granuloma demonstrated peripheral enhanced exophytic renal mass mimic renal cell carcinoma, and underwent surgery. At the solid renal mass with different radiological features, biopsy is an option to determining the necessity of surgery as well as the surgical approach.

  2. Renal transplant failure due to urologic complications: Comparison of static fluid with contrast-enhanced magnetic resonance urography

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D. [University Hospital Duesseldorf, Institute of Diagnostic Radiology, Moorenstr. 5, D-40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de; Koester, A.; Andersen, K.; Kurz, K.D.; Moedder, U.; Cohnen, M. [University Hospital Duesseldorf, Institute of Diagnostic Radiology, Moorenstr. 5, D-40225 Duesseldorf (Germany)

    2009-02-15

    Purpose: Postrenal reasons of renal transplant failure can be assessed by magnetic resonance urography. This study was designed to retrospectively compare the diagnostic accuracy of static fluid (T2-)MRU compared to contrast enhanced (CE-)MRU in patients with renal transplant failure. Material and methods: Thirty-five consecutive patients (14 female, 21 men; mean age 48.6 years) with renal transplant failure and sonographically detected hydronephrosis were examined both with T2-MRU as well as CE-MRU resulting in 39 MRU examinations. MRU was performed both using T2-weighted HASTE-sequence (T2-MRU) as well as Gadolinium-enhanced 3D-FLASH-sequence (CE-MRU) on a 1.5-T clinical MRI scanner (Magnetom Vision, Siemens Medical Solutions). Subjective image quality of resulting maximum intensity projection was assessed in consensus by two readers blinded to the final diagnosis, using a five point scale. MRU findings were correlated to sonography, operative results or clinical follow up. Results: CE-MRU yielded a sensitivity of 85.7% (T2-MRU 76.2%), and a specificity of 83.3% (T2-MRU: 73.7%), however statistical significance was not reached. The subjective image quality was significantly better in CE-MRU. Conclusions: Only concerning subjective image quality CE-MRU proved superior to T2-MRU. Yet, there was no significant difference in diagnostic accuracy between T2- and CE-MRU. Thinking of incipient nephrogenic systemic fibrosis, T2-MRU can be used as reliable alternative in patients with decreased renal transplant function due to urological complications.

  3. Renal transplant failure due to urologic complications: Comparison of static fluid with contrast-enhanced magnetic resonance urography.

    Science.gov (United States)

    Blondin, D; Koester, A; Andersen, K; Kurz, K D; Moedder, U; Cohnen, M

    2009-02-01

    Postrenal reasons of renal transplant failure can be assessed by magnetic resonance urography. This study was designed to retrospectively compare the diagnostic accuracy of static fluid (T2-)MRU compared to contrast enhanced (CE-)MRU in patients with renal transplant failure. Thirty-five consecutive patients (14 female, 21 men; mean age 48.6 years) with renal transplant failure and sonographically detected hydronephrosis were examined both with T2-MRU as well as CE-MRU resulting in 39 MRU examinations. MRU was performed both using T2-weighted HASTE-sequence (T2-MRU) as well as Gadolinium-enhanced 3D-FLASH-sequence (CE-MRU) on a 1.5-T clinical MRI scanner (Magnetom Vision, Siemens Medical Solutions). Subjective image quality of resulting maximum intensity projection was assessed in consensus by two readers blinded to the final diagnosis, using a five point scale. MRU findings were correlated to sonography, operative results or clinical follow up. CE-MRU yielded a sensitivity of 85.7% (T2-MRU 76.2%), and a specificity of 83.3% (T2-MRU: 73.7%), however statistical significance was not reached. The subjective image quality was significantly better in CE-MRU. Only concerning subjective image quality CE-MRU proved superior to T2-MRU. Yet, there was no significant difference in diagnostic accuracy between T2- and CE-MRU. Thinking of incipient nephrogenic systemic fibrosis, T2-MRU can be used as reliable alternative in patients with decreased renal transplant function due to urological complications.

  4. Effects of recombinant human erythropoietin on the haemopoietic bone marrow monitored by magnetic resonance spectroscopy in patients with end-stage renal disease

    DEFF Research Database (Denmark)

    Jensen, K E; Stenver, D; Jensen, M;

    1990-01-01

    Volume selective magnetic resonance (MR) proton spectroscopy was used to investigate changes in the haemopoietic bone marrow in patients with end-stage renal disease undergoing treatment with recombinant human erythropoietin (rHuEPO). Significant changes could be detected in the spectra 14 days...

  5. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... and Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options ... usually given through an IV in the arm. MRI Research Programs at FDA Magnetic Resonance Imaging (MRI) ...

  6. Agreement between static magnetic resonance urography and diuretic renal scintigraphy in patients with ureteropelvic junction obstruction after pyeloplasty.

    Science.gov (United States)

    Mazdak, Hamid; Karam, Mehdi; Ghassami, Fatemeh; Malekpour, Alireza

    2015-01-01

    Ureteropelvic junction obstruction (UPJO) is the most common cause of hydronephrosis within childhood that usually treat by surgery. According to anatomical variations in different individuals, scheduling similar procedures for all patients is not suitable, and thus the best decision for an appropriate surgical technique should be considered separately for each patient. Regardless of the type of applied technique, creating a funnel-shape UPJ with a suitable size is a successful treatment. In this context, the assessment of a successful surgical treatment in a short-term follow-up means repairing revealed anatomical defects. The present study aimed to compare the diagnostic value of static magnetic resonance urography (MRU) and diuretic-based renalscintigraphy (DRS) in patients with UPJO after pyeloplasty. A total of 30 consecutive patients with UPJO, who underwent unilateral pyeloplasty between 2012 and 2013 were assessed. All subjects underwent DRS and also MRU about 1-month after the former procedure. The Kendall's tau correlation showed a very strong correlation between results of MRU and diuretic renal scintigraphy (r = 0.932, P MRU to assess UPJO. MRU static fluid has a high accuracy for assessment of renal system anatomy. Due to the lack of dangerous consequences of contrast materials, MRU can be the best option instead of DRS.

  7. Imaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry

    DEFF Research Database (Denmark)

    Reed, Galen D; von Morze, Cornelius; Verkman, Alan S

    2016-01-01

    originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent pools of the [(13)C,(15)N2]urea to be distinguished via multi-exponential analysis. The T2 response to induced diuresis and antidiuresis was performed with two imaging agents: hyperpolarized [(13)C,(15...

  8. 3D FIESTA pulse sequence for assessing renal artery stenosis: is it a reliable application in unenhanced magnetic resonance angiography?

    Science.gov (United States)

    Gaudiano, Caterina; Busato, Fiorenza; Ferramosca, Emiliana; Cecchelli, Carlo; Corcioni, Beniamino; De Sanctis, Lucia Barbara; Santoro, Antonio; Golfieri, Rita

    2014-12-01

    To assess the capability of the three-dimensional (3D) Fast Imaging Employing Steady-State Acquisition (FIESTA) sequence in evaluating renal artery stenosis (RAS). We retrospectively analysed 79 patients referred for suspected RAS, examined by 3D FIESTA and contrast-enhanced magnetic resonance angiography (CE-MRA), using a 1.5T whole-body scanner. Image quality was assessed as well as the presence and grade of RAS. Patients with RAS ≥ 50% were evaluated for possible digital subtraction angiography (DSA). Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of 3D FIESTA were calculated with ROC analysis using CE-MRA and DSA as the standard of reference. A total of 186 renal arteries were assessed; 36 had RAS ≥ 50 % demonstrated by CE-MRA. Ten patients underwent DSA, for a total evaluation of 22 arteries. Sensitivity, specificity, NPV, PPV, and accuracy of 3D FIESTA were 91.7%, 100%, 98%, 100%, and 98%, respectively, as compared to CE-MRA, and 88.2%, 100%, 71.4%, 100%, and 91%, respectively, as compared to DSA. The area under the ROC curve (AUC) of 3D FIESTA as compared to CE-MRA and DSA was 0.958 and 0.941, respectively. Our study demonstrated the capability of the 3D FIESTA sequence in evaluating RAS, with high-quality images and good diagnostic accuracy. The 3D FIESTA sequence provides a robust evaluation of RAS. The 3D FIESTA sequence allows non-invasive evaluation of the renal arteries. The 3D FIESTA sequence could be a useful tool in evaluating RAS.

  9. Magnetic resonance angiography in the evaluation of renal arteries: imaging findings; Angiografia por ressonancia magnetica na avaliacao das arterias renais: achados de imagem

    Energy Technology Data Exchange (ETDEWEB)

    Nacif, Marcelo Souto [Faculdade de Medicina de Teresopolis, RJ (Brazil). Curso de Radiologia]. E-mail: msnacif@yahoo.com.br; Santos, Alair Augusto Sarmet Moreira Damas dos [Instituto de Pos-graduacao Medica Carlos Chagas (VOT-Imagem), Rio de Janeiro, RJ (Brazil). Curso de Especializacao em Radiologia; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: msnacif@yahoo.com.br

    2006-07-15

    Objective: to describe indications, main findings and diagnosis of magnetic resonance angiographies of renal arteries. Materials and methods: a retrospective study including 56 imaging studies covering a total of 111 renal arteries, performed during the period between December 6, 2001 and March 11, 2004. The angiographies were performed in a 1.5 T scanner, in compliance with the Department protocol. Results: as regards sex, it was found that 55.4% (n = 31) patients were male and 44.6% (n = 25) were female. The youngest patient was 12 years old and the oldest 88 years old. From a total of 25 different clinical indications, systemic arterial hypertension was the principal one with 26.7% (n = 15), followed by abdominal and/or lumbar pain with 12.5% (n 7), abdominal aortic aneurysm with 10.7% (n = 6), renal artery stenosis with 8.9% (n = 5), and others. Among these 56 studies, 43 (76.7%) had different types of findings and 13 (23.2%) were normal. The majority of findings were related to vascular diameter and amongst them, parietal irregularities, aneurysms and stenosis were the most frequent. Parietal irregularity was the most frequent alteration in the right renal artery with 17.87% (n = 10) and stenosis, in the left renal artery, with 25.45% (n = 14). Conclusion: magnetic resonance angiography has shown to be an excellent non-invasive method for evaluation of renal arteries, because of its sensitivity and multiplanar capacity for demonstrating vascular structures. (author)

  10. Functional magnetic resonance imaging for evaluation of radiation-induced renal damage; Funktionelle MRT der Niere zur Erfassung strahleninduzierter Nierenschaedigungen

    Energy Technology Data Exchange (ETDEWEB)

    Haneder, S.; Schoenberg, S.O.; Michaely, H.J. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Boda-Heggemann, J. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Klinik fuer Strahlentherapie und Radioonkologie, Mannheim (Germany)

    2012-03-15

    The diagnosis of radiation-induced (especially chronic) renal alterations/damage is difficult and currently relies primarily on clinical evaluation. The importance of renal diagnostic evaluation will increase continuously due to the increasing number of long-term survivors after radiotherapy. This article evaluates the potentia diagnostic contribution of magnetic resonance (MR) imaging with a focus on functional MRI. The following functional MRI approaches are briefly presented and evaluated: blood oxygenation level-dependent imaging (BOLD), diffusion-weighted imaging (DWI) or diffusion tensor imaging (DTI), MR perfusion measurements and {sup 23}Na imaging. In summary, only DWI and contrast-enhanced MR perfusion currently seem to be suitable approaches for a broader, clinical implementation. However, up to now valid data from larger patient studies are lacking for both techniques in regard to radiation-induced renal alterations. The BOLD and {sup 23}Na imaging procedures have a huge potential but are currently neither sufficiently evaluated with regard to radiation-induced renal alterations nor technically simple and reliable for implementation into the clinical routine. (orig.) [German] Die Diagnostik strahleninduzierter, insbesondere chronischer Schaedigungen der Niere ist nach wie vor schwierig und beruht primaer auf der klinischen Beurteilung. Durch die zunehmende Anzahl von Langzeitueberlebenden nach einer Strahlentherapie wird die Bedeutung dieser Diagnostik jedoch weiter zunehmen. In diesem Beitrag wird der Frage nachgegangen, in wieweit hierzu die MRT-Bildgebung und hier besonders die funktionellen Bildgebungsmodalitaeten ihren Beitrag leisten koennen. Die folgenden Verfahren werden kurz vorgestellt und bewertet: die Blood-oxygenation-level-dependent-Bildgebung (BOLD), die diffusionsgewichtete Bildgebung (''diffusion-weighted imaging'', DWI) bzw. das ''diffusion tensor imaging'' (DTI), die MR-Perfusionsmessungen, und

  11. Differences in Renal Tumor Size Measurements for Computed Tomography Versus Magnetic Resonance Imaging: Implications for Patients on Active Surveillance.

    Science.gov (United States)

    Khan, Irtaza; Beksac, Alp Tuna; Paulucci, David J; Abaza, Ronney; Eun, Daniel D; Bhandari, Akshay; Badani, Ketan K

    2017-08-11

    To evaluate and compare the accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) in predicting the final pathologic tumor size of partial nephrectomy specimens. We analyzed a multi-institutional database of 807 patients who underwent robotic partial nephrectomy for a cT1a renal mass from 2006 to 2016. Patients who had a solitary tumor with complete data on the baseline imaging modality and the tumor size (baseline and pathologic) (n = 349) were included for analysis. Baseline tumor size evaluated by both imaging modalities, in addition to the difference between the measurements and final pathologic tumor size (cm) measurements, was compared between patients who received a baseline CT (n = 276, 79.1%) and those who received an MRI (n = 73, 20.9%). There were no statistically significant differences between any baseline characteristics and receipt of a CT versus MRI. In multivariable analysis adjusting for confounders, there was no significant difference in the baseline tumor size between patients receiving an MRI and those receiving a CT (2.3 versus 2.6 cm; β = -0.13; 95% confidence interval [CI] = -0.33 to 0.07; P = .208). Tumor size on imaging was smaller from final pathology by 0.43 cm on average (P = .002). Measurement error for the measured baseline versus actual pathologic tumor size did not significantly differ for patients receiving an MRI versus those receiving a CT (0.38 versus 0.44 cm; β = -0.06; 95% CI = -0.16 to 0.04; P = .232). Baseline renal tumor size measurements were not significantly different for CT scan and MRI. Choice of imaging modality can be based on doctor and patient preference, including cost and exposure to radiation.

  12. Renal medullary carcinoma: sonographic, computed tomography, magnetic resonance and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Ali E-mail: drkhan@primedia.co.uk; Thomas, Nigel; Costello, Brandon; Jobling, Louis; Kretser, Dan de; Broadfield, Emma; O' Shea, Sarah

    2000-07-01

    Renal medullary carcinoma is a recently described, highly aggressive tumour, occurring predominantly in young patients of African descent with sickle cell trait (SCT). All have been metastatic at surgery. Surgery, radiotherapy and chemotherapy do not appear to alter the course of the disease. The survival time is very short. Presentation is usually with haematuria, abdominal pain and weight loss. Forty-nine patients have been reported from the USA, of these 47 were African/Americans. The reports have mostly appeared in pathology journals. On review of the imaging findings reported in the radiological journals, it becomes apparent that it is possible for a radiologist to suggest a specific diagnosis in the appropriate demographic and clinical setting. Here the first British patient of Afro-Caribbean decent in whom a pre-operative diagnosis was suggested on the imaging findings of a centrally located renal pelvic tumour, encasing the pelvis on a background of SCT in a 28-year-old is described. It is expected that a high index of suspicion in the appropriate clinical setting may lead to earlier diagnosis, treatment and survival of patients. The patient is alive and reasonably well 9 months after surgery. The full range of imaging findings in renal medullary carcinoma are described.

  13. Imaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry

    Science.gov (United States)

    Reed, Galen D.; von Morze, Cornelius; Verkman, Alan S.; Koelsch, Bertram L.; Chaumeil, Myriam M.; Lustig, Michael; Ronen, Sabrina M.; Bok, Robert A.; Sands, Jeff M.; Larson, Peder E. Z.; Wang, Zhen J.; Larsen, Jan Henrik Ardenkjær; Kurhanewicz, John; Vigneron, Daniel B.

    2016-01-01

    In vivo spin spin relaxation time (T2) heterogeneity of hyperpolarized [13C,15N2]urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized 13C signal with a macromolecular relaxation agent revealed that a long-T2 component of the [13C,15N2]urea signal originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent pools of the [13C,15N2]urea to be distinguished via multi-exponential analysis. The T2 response to induced diuresis and antidiuresis was performed with two imaging agents: hyperpolarized [13C,15N2]urea and a control agent hyperpolarized bis-1,1-(hydroxymethyl)-1-13C-cyclopropane-2H8. Large T2 increases in the inner-medullar and papilla were observed with the former agent and not the latter during antidiuresis. Therefore, [13C,15N2]urea relaxometry is sensitive to two steps of the renal urea handling process: glomerular filtration and the inner-medullary urea transporter (UT)-A1 and UT-A3 mediated urea concentrating process. Simple motion correction and subspace denoising algorithms are presented to aid in the multi exponential data analysis. Furthermore, a T2-edited, ultra long echo time sequence was developed for sub-2 mm3 resolution 3D encoding of urea by exploiting relaxation differences in the vascular and filtrate pools. PMID:27570835

  14. Research cardiac magnetic resonance imaging in end stage renal disease - incidence, significance and implications of unexpected incidental findings

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Elaine; Weir-McCall, Jonathan R.; Houston, J.G.; Struthers, Allan D. [Ninewells Hospital, Division of Cardiovascular and Diabetes Medicine, Dundee (United Kingdom); Patel, Rajan K.; Jardine, Alan G.; Mark, Patrick B. [Institute of Cardiovascular and Medical Sciences, Glasgow (United Kingdom); Roditi, Giles [NHS Greater Glasgow and Clyde, Department of Radiology, Glasgow Royal Infirmary, Glasgow (United Kingdom)

    2017-01-15

    Left ventricular mass (LVM) at cardiac magnetic resonance imaging (CMR) is a frequent end point in clinical trials in nephrology. Trial participants with end stage renal disease (ESRD) may have a greater frequency of incidental findings (IF). We retrospectively investigated prevalence of IF in previous research CMR and reviewed their subsequent impact on participants. Between 2002 and 2006, 161 ESRD patients underwent CMR in a transplant assessment study. Images were used to assess LV mass and function. In the current study a radiologist reviewed the scans for IF. Review of patient records determined the subsequent clinical significance of IF. There were 150 IF in 95 study participants. Eighty-four (56 %) were new diagnoses. One hundred and two were non-cardiac. Fifteen were suspicious of malignancy. There was a clinically significant IF for 14.9 % of the participants. In six cases earlier identification of an IF may have improved quality of life or survival. Without radiology support clinically important IF may be missed on CMR. Patients undergoing CMR in trials should be counselled about the frequency and implications of IF. Patients with ESRD have a higher prevalence of IF than reported in other populations. Nephrology studies require mechanisms for radiologist reporting and strategies for dealing with IF. (orig.)

  15. Detection of obstructive uropathy and assessment of differential renal function using two functional magnetic resonance urography tools. A comparison with diuretic renal scintigraphy in infants and children.

    Science.gov (United States)

    Genseke, Philipp; Rogasch, Julian M M; Steffen, Ingo G; Neumann, Grit; Apostolova, Ivayla; Ruf, Juri; Rißmann, Anke; Wiemann, Dagobert; Liehr, Uwe-Bernd; Schostak, Martin; Amthauer, Holger; Furth, Christian

    2017-02-14

    After detection of obstructive uropathy (OU), the indication for or against surgery is primarily based on the differential renal function (DRF). This is to compare functional magnetic resonance urography (fMRU) with dynamic renal scintigraphy (DRS) to assess OU and DRF in infants and children. Retrospective analysis in 30 patients (female: 16; male: 14; median age: 5.5 years [0.2-16.5]), divided into subgroup A (age: 0-2 years; n = 16) and B (> 2-17 years; n = 14). fMRU was assessed by measuring renal transit time (RTT) and volumetric DRF with CHOP fMRU tool (CT) and ImageJ MRU plug-in (IJ). OU detection by fMRU was compared with DRS (standard of reference) using areas under the curves (AUC) in ROC analyses. Concordant DRF was assumed if absolute deviation between fMRU and DRS was ≤ 5 %. DRS confirmed fixed OU in 4/31 kidneys (12.9 %) in subgroup A. AUC of CT was 0.94 compared with 0.93 by IJ. Subgroup B showed fixed OU in 1/21 kidneys (4.8 %) with AUCs of 0.98 each. RTT measured neither by CT nor by IJ in confirmed fixed OU was < 1200 s - resulting in negative predictive values of 1.0 each. In subgroup A, DRF was concordant in 81.3 % of the kidneys for CT and DRS compared with 75.0 % for IJ and DRS. In subgroup B, CT and DRS were concordant in 91.7 %, and IJ and DRS in 45.8 % of the kidneys. fMRU accurately excluded fixed OU in infants and children, independent from the software used for quantification. However, assessment of DRF with fMRU deviated from DRS especially in infants who may profit most from early intervention. Thus, fMRU cannot fully replace DRS as primary functional examination. If, for clinical reasons, fMRU is performed in first place and it cannot exclude fixed OU, it should be followed by DRS for validation and DRF quantification.

  16. Imaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry

    CERN Document Server

    Reed, Galen D; Verkman, Alan S; Koelsch, Bertram L; Chaumeil, Myriam M; Lustig, Michael; Ronen, Sabrina M; Sands, Jeff M; Larson, Peder E Z; Wang, Zhen J; Larsen, Jan Henrik Ardenkjær; Vigneron, Daniel B

    2015-01-01

    \\textit{In vivo} spin spin relaxation time ($T_2$) heterogeneity of hyperpolarized \\textsuperscript{13}C urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized \\textsuperscript{13}C signal with a macromolecular relaxation agent revealed that a long-$T_2$ component of the \\textsuperscript{13}C urea signal originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent pools of the \\textsuperscript{13}C urea to be distinguished via multi-exponential analysis. The $T_2$ response to induced diuresis and antidiuresis was performed with two imaging agents: hyperpolarized \\textsuperscript{13}C urea and a control agent hyperpolarized bis-1,1-(hydroxymethyl)-1-\\textsuperscript{13}C-cyclopropane-$^2\\textrm{H}_8$. Large $T_2$ increases in the inner-medullar and papilla were observed with the former agent and not the latter during antidiuresis suggesting that $T_2$ relaxometry may be used to monitor the inner-medullary urea transporter (UT)-...

  17. Pediatric magnetic resonance urography.

    Science.gov (United States)

    Jones, Richard A; Grattan-Smith, J Damien; Little, Stephen

    2011-03-01

    Magnetic resonance urography (MRU) is a powerful clinical tool that fuses anatomic information with functional data in a single test without the use of ionizing radiation. This article provides an overview of the technical aspects, as well as common clinical applications with an emphasis on the evaluation of hydronephrosis. A fluid challenge is an essential part of our MRU protocol and enables the definition of compensated or decompensated kidneys within the spectrum of hydronephrosis. This classification may have prognostic implications when surgery is being considered. In addition, underlying uropathy can be identified on the anatomical scans and renal scarring can be seen on both the anatomical and dynamic scans. MRU can identify and categorize dysmorphic kidneys in vivo and may provide insight into congenital abnormalities seen in conjunction with vesicoureteric reflux. MRU is still in its infancy and as the technique develops and becomes widely available, it seems likely that it will supplant renal scintigraphy in the evaluation of renal tract disorders in children. Copyright © 2011 Wiley-Liss, Inc.

  18. Dynamic Contrast-Enhanced Magnetic Resonance Imaging of Vascular Changes Induced by Sunitinib in Papillary Renal Cell Carcinoma Xenograft Tumors

    Directory of Open Access Journals (Sweden)

    Gilda G. Hillman

    2009-09-01

    Full Text Available To investigate further the antiangiogenic potential of sunitinib for renal cell carcinoma (RCC treatment, its effects on tumor vasculature were monitored by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI using an orthotopic KCI-18 model of human RCC xenografts in nude mice. Tumor-bearing mice were treated with various doses of sunitinib, and vascular changes were assessed by DCE-MRI and histologic studies. Sunitinib induced dose-dependent vascular changes, which were observed both in kidney tumors and in normal kidneys by DCE-MRI. A dosage of 10 mg/kg per day caused mild changes in Gd uptake and clearance kinetics in kidney tumors. A dosage of 40 mg/kg per day induced increased vascular tumor permeability with Gd retention, probably resulting from the destruction of tumor vasculature, and also caused vascular alterations of normal vessels. However, sunitinib at 20 mg/kg per day caused increased tumor perfusion and decreased vascular permeability associated with thinning and regularization of tumor vessels while mildly affecting normal vessels as confirmed by histologic diagnosis. Alterations in tumor vasculature resulted in a significant inhibition of KCI-18 RCC tumor growth at sunitinib dosages of 20 and 40 mg/kg per day. Sunitinib also exerted a direct cytotoxic effect in KCI-18 cells in vitro. KCI-18 cells and tumors expressed vascular endothelial growth factor receptor 2 and platelet-derived growth factor receptor β molecular targets of sunitinib that were modulated by the drug treatment. These data suggest that a sunitinib dosage of 20 mg/kg per day, which inhibits RCC tumor growth and regularizes tumor vessels with milder effects on normal vessels, could be used to improve blood flow for combination with chemotherapy. These studies emphasize the clinical potential of DCE-MRI in selecting the dose and schedule of antiangiogenic compounds.

  19. Role of high resolution contrast-enhanced magnetic resonance angiography (HR CeMRA) in management of arterial complications of the renal transplant

    Energy Technology Data Exchange (ETDEWEB)

    Ismaeel, M. Maged [Suez Canal University (Egypt); Abdel-Hamid, Azza, E-mail: azza4951@hotmail.com [Suez Canal University (Egypt)

    2011-08-15

    Introduction: Transplant renal artery (RA) stenosis (TRAS) is the most frequent posttransplantation vascular complication. Contrast enhanced magnetic resonance (CeMRA) angiography has been established as the preferred imaging technique for the evaluation of TRAS because it does not require the use of iodinated contrast material and does not expose the patient to ionizing radiation. Digital subtraction angiography (DSA) is the gold standard in the evaluation of arterial tree of the renal allograft. Aim of the work: This study was carried out to assess the accuracy of CeMRA in the detection of arterial complications after renal transplantation. Patients and methods: Thirty renal transplant patients with suspected arterial complications in which both CeMRA and DSA were performed were included in the study. The HR CeMRA shows 93.7% sensitivity, 80% specificity, 88.2% positive predictive value, 88.9% negative predictive value and 88.5% accuracy. Conclusion: HR CeMRA is an accurate reliable tool in the assessment of arterial complications after renal transplantation. It may replace DSA as a diagnostic modality with reservation of interventional techniques for endovascular treatment of suitable cases.

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses ... of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical ...

  1. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children and Radiation ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children and Radiation Safety ...

  4. Comparison of magnetic resonance urography to dimercaptosuccinic acid scan for the identification of renal parenchyma defects in children with vesicoureteral reflux.

    Science.gov (United States)

    Cerwinka, W H; Grattan-Smith, J D; Jones, R A; Haber, M; Little, S B; Blews, D E; Williams, J P; Kirsch, A J

    2014-04-01

    The objective of this study was to compare the accuracy of dimercaptosuccinic acid (DMSA) renal scan to magnetic resonance urography (MRU) in the identification of renal parenchyma defects (RPD). Twenty-five children with history of acute pyelonephritis and vesicoureteral reflux underwent DMSA scan and MRU to determine the presence of RPD. DMSA scans and MRUs were each evaluated by two radiologists and agreement achieved by consensus. Discordant DMSA-MRU findings were re-evaluated in a side-by-side comparison and an ultimate consensus reached. The ultimate consensus diagnosis was 18 kidneys with RPDs in 15 patients, of which five were classified as mild RPDs, six as moderate RPDs, and seven as severe RPDs. Although DMSA scan and MRU were similar in their ability to diagnose RPDs, MRU was considered to represent the true diagnosis in 11 of the 12 discordant cases in consensus review by four pediatric radiologists. MRU showed a much higher inter-observer agreement with a weighted kappa of 0.96 for both kidneys compared to 0.71 for the right kidney and 0.86 for the left kidney by DMSA scan. Our results suggest that MRU is superior to DMSA scan in the identification of renal parenchyma defects. Copyright © 2013 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  5. High altitude may alter oxygen availability and renal metabolism in diabetics as measured by hyperpolarized [1-1C]pyruvate magnetic resonance imaging

    DEFF Research Database (Denmark)

    Laustsen, Christoffer; Lycke, Sara; Palm, Fredrik;

    2014-01-01

    The kidneys account for about 10% of the whole body oxygen consumption, whereas only 0.5% of the total body mass. It is known that intrarenal hypoxia is present in several diseases associated with development of kidney disease, including diabetes, and when renal blood flow is unaffected. The impo...... of nephropathy in patients with diabetes at high altitudes may originate from the increased sensitivity toward inspired oxygen. This increased lactate production shifts the metabolic routs toward hypoxic pathways.......The kidneys account for about 10% of the whole body oxygen consumption, whereas only 0.5% of the total body mass. It is known that intrarenal hypoxia is present in several diseases associated with development of kidney disease, including diabetes, and when renal blood flow is unaffected....... The importance of deranged oxygen metabolism is further supported by deterioration of kidney function in patients with diabetes living at high altitude. Thus, we argue that reduced oxygen availability alters renal energy metabolism. Here, we introduce a novel magnetic resonance imaging (MRI) approach to monitor...

  6. New Magnetic Resonance Imaging Index for Renal Fibrosis Assessment: A Comparison between Diffusion-Weighted Imaging and T1 Mapping with Histological Validation

    Science.gov (United States)

    Friedli, I.; Crowe, L. A.; Berchtold, L.; Moll, S.; Hadaya, K.; de Perrot, T.; Vesin, C.; Martin, P.-Y.; de Seigneux, S.; Vallée, J.-P.

    2016-01-01

    A need exists to noninvasively assess renal interstitial fibrosis, a common process to all kidney diseases and predictive of renal prognosis. In this translational study, Magnetic Resonance Imaging (MRI) T1 mapping and a new segmented Diffusion-Weighted Imaging (DWI) technique, for Apparent Diffusion Coefficient (ADC), were first compared to renal fibrosis in two well-controlled animal models to assess detection limits. Validation against biopsy was then performed in 33 kidney allograft recipients (KARs). Predictive MRI indices, ΔT1 and ΔADC (defined as the cortico-medullary differences), were compared to histology. In rats, both T1 and ADC correlated well with fibrosis and inflammation showing a difference between normal and diseased kidneys. In KARs, MRI indices were not sensitive to interstitial inflammation. By contrast, ΔADC outperformed ΔT1 with a stronger negative correlation to fibrosis (R2 = 0.64 against R2 = 0.29 p < 0.001). ΔADC tends to negative values in KARs harboring cortical fibrosis of more than 40%. Using a discriminant analysis method, the ΔADC, as a marker to detect such level of fibrosis or higher, led to a specificity and sensitivity of 100% and 71%, respectively. This new index has potential for noninvasive assessment of fibrosis in the clinical setting. PMID:27439482

  7. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  8. Dynamic gadolinium-enhanced magnetic resonance urography for assessing drainage in dilated pelvicalyceal systems with moderate renal function: preliminary results and comparison with diuresis renography.

    Science.gov (United States)

    Chu, W C W; Lam, W W M; Chan, K W; Yeung, C K; Lee, K H; Sihoe, J D Y

    2004-04-01

    To evaluate the use of dynamic gadolinium diethylenetriaminepenta-acetic acid (DTPA)-enhanced magnetic resonance urography (Gd-MRU) for assessing kidneys with markedly dilated pelvicalyceal systems and impaired function. Eight children (mean age 30 months, sd 25) were assessed, diagnosed as having gross unilateral hydronephrosis with a mean (sd) anteroposterior renal pelvic diameter of 36 (7) mm and reduced (30-40%) renal function. Dynamic Gd-MRU was performed after the patients were pre-loaded with intravenous fluid and diuretics, and comprised a dynamic T1-weighted sequence after Gd-DTPA (0.1 mmol/kg body weight) was administered, with a time-intensity curve of each kidney produced. Drainage was diagnosed by a clearly declining time-intensity curve and direct visualization of contrast medium within the ureter in several frames. High-grade or complete obstruction was diagnosed when drainage of contrast medium could not be detected. Gd-MRU results were compared with diuresis radionuclide (mercapto-acetyltriglycine, MAG3) renography within the same week. Unobstructive units detected by Gd-MRU were treated conservatively with a close follow-up by ultrasonography and radionuclide studies. Diuresis MAG3 renography showed drainage in three dilated units and poor washout in five; in contrast, Gd-MRU showed drainage in seven dilated systems (three showed poor washout by MAG3), and obstruction in the remaining case. The unobstructed units detected by MRU under conservative treatment thus showed no further deterioration of renal function or progressive hydronephrosis in the subsequent follow-up (mean 18 months, range 15-23). These preliminary results suggest that dynamic Gd-MRU is a useful noninvasive imaging method in distinguishing obstructive from unobstructive dilated systems, particularly in patients with hydronephrosis and reduced renal function.

  9. High prevalence of nephrogenic systemic fibrosis in chronic renal failure patients exposed to gadodiamide, a gadolinium-containing magnetic resonance contrast agent

    DEFF Research Database (Denmark)

    Rydahl, Casper; Thomsen, Henrik S; Marckmann, Peter

    2008-01-01

    OBJECTIVE: Nephrogenic systemic fibrosis (NSF) is a serious disease affecting renal failure patients. It may be caused by some gadolinium (Gd)-containing contrast agents, including gadodiamide. The study aimed at estimating the prevalence of NSF after gadodiamide exposure for patients with chronic...... kidney disease (CKD). MATERIALS AND METHODS: Retrospective cohort study of 190 consecutive nephrological patients in different categories of kidney function referred for gadodiamide-enhanced magnetic resonance imaging in the period January 1, 2004 to March 21, 2006. RESULTS: Eighteen patients (18/190; 10......%, 95% CI: 6%-15%) were diagnosed with NSF within a mean follow-up period of 29 months (range 16-43 months). All 18 cases had stage 5 CKD (ie, estimated glomerular filtration rate less than 15 mL/min/1.73 m2 or in dialysis therapy) at the time of their gadodiamide exposure. The prevalence of NSF among...

  10. Exploring the elusive link between subclinical fibrosis and clinical events in end-stage renal disease: does cardiac magnetic resonance imaging hold the key?

    Science.gov (United States)

    Shroff, Gautam R; Raggi, Paolo

    2016-10-01

    Extensive myocardial fibrosis is known to occur in patients undergoing dialysis due to a variety of mechanisms not necessarily restricted to coronary artery disease. Fibrosis may predispose to reentry arrhythmias and long-term myocardial dysfunction, and sudden death and congestive heart failure are the most frequent causes of death in patients undergoing renal replacement therapy. Despite the high accuracy of magnetic resonance for imaging of myocardial fibrosis, its use has been restricted by the risk of inducing nephrogenic systemic sclerosis with the injection of gadolinium. The development of new sequences that allow the detection and quantifying of the severity of extracellular myocardial fibrosis offers a chance to study the pathogenesis of this condition and identify potential interventions to retard or reverse it. Whether these will lead to an improved outcome needs to be prospectively tested.

  11. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging ( ... if possible, or removed prior to the MRI scan. Because they can interfere with the magnetic field ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio ...

  15. Fabrication of mAb G250-SPIO molecular magnetic resonance imaging nanoprobe for the specific detection of renal cell carcinoma in vitro.

    Directory of Open Access Journals (Sweden)

    Cailuan Lu

    Full Text Available Molecular magnetic resonance imaging (mMRI has been paid more and more attention for early diagnosis of cancer. A sensitive and specific mMRI probe plays the most important role in this technique. In this study, superparamagnetic iron oxide (SPIO nanoparticles and mAb G250 were conjugated as mMRI probe for the detection of clear cell renal cell carcinoma (ccRCC using 3.0-Tesla MRI in vitro. mAb G250 could specifically recognize carbonic anhydrase IX (CAIX antigen overexpressed in ccRCC and the SPIO nanoparticles as MRI contrast agent presented excellent MRI response and good biocompatibility. The successful assembly of this nanoprobe was confirmed by UV-vis spectrum, FT-IR spectroscopy and DLS analysis. In vitro MRI study on ccRCC cells and control cells indicated that our fabricated mAb G250-SPIO nanoprobe could be used in the specific labeling of clear cell renal carcinoma cells successfully.

  16. Half Fourier single-shot turbo spin-echo magnetic resonance urography for the evaluation of suspected renal colic in pregnancy.

    Science.gov (United States)

    Mullins, Jeffrey K; Semins, Michelle J; Hyams, Elias S; Bohlman, Mark E; Matlaga, Brian R

    2012-06-01

    To report our experience with magnetic resonance urography (MRU) in pregnant women suspected of having obstructing upper tract calculi. The diagnosis of an upper tract calculus in the pregnant woman can be challenging. Recent evidence suggests that MRU can be used to effectively evaluate renal colic. From 2008-2011, 9 pregnant women were referred for evaluation of suspected renal colic caused by an obstructing upper tract stone. All patients underwent MRU with a half Fourier single-shot turbo spin-echo (HASTE) protocol. Medical records and imaging studies were reviewed for demographic and clinical data as well as outcome measures. The mean age of the subjects was 25 years (range 20-34); average gestational age of the fetus was 23 weeks (range 9-36). In all cases, a renal ultrasound was the initial imaging study obtained, with nondiagnostic findings. HASTE MRU detected 4 ureteral stones and 4 cases of physiological hydronephrosis of pregnancy. In one case, interpretation of the MRU was limited as a result of patient motion. Of the patients with obstructing stones, 1 required endourologic management during her pregnancy and 3 were followed conservatively. No adverse events related to MRU occurred. HASTE MRU is an informative imaging study for pregnant women with suspected upper tract stone disease. Information gathered from this study augments that gained from alternative modalities, and aids in medical decision-making. The lack of ionizing radiation exposure, coupled with the capture of detailed anatomic imaging, makes HASTE MRU a particularly useful study in this setting. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. A multi-center, comparative, phase 3 study to determine the efficacy of gadofosveset-enhanced magnetic resonance angiography for evaluation of renal artery disease

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, Robert [St. Boniface General Hospital, Winnipeg, Manitoba (Canada); Vymazal, Josef [Hospital Na Homolce, Prague (Czech Republic); Martinez-Lopez, Manuel [Hospital Medica Sur, Mexico City (Mexico); Neuwirth, Jiri [Faculty Hospital Motol, Prague (Czech Republic); Salgado, Perla [American British Cowdray Medical Center, Mexico City (Mexico); Beregi, Jean-Paul [Hopital Cardiologique, Lille (France); Peduto, Anthony [Westmead Hospital, Westmead New South Wales (Australia); Pena-Almaguer, Erasmo de la [Christus-Muguerza Medical Center, Monterrey, Nuevo Leon (Mexico); Slater, Greg J. [Greenslopes Private Hospital, Greenslopes, Queensland (Australia); Shamsi, Kohkan [Berlex Laboratories, Montville, NJ (United States); Parsons, Edward C. [EPIX Pharmaceuticals, Inc., Lexington, MA (United States)], E-mail: eparsons@epixpharma.com

    2008-02-15

    Purpose: To determine prospectively the safety and efficacy of the blood-pool contrast agent gadofosveset trisodium in renal artery magnetic resonance angiography (MRA). Materials and methods: Gadofosveset (0.03 mmol/kg) was administered to adult patients with known or suspected renal arterial disease in a multi-center phase 3 single dose study. The drug binds reversibly to albumin, prolonging the blood residence time, and allowing collection of images in the first-pass and steady-state phases. The combination of these images was compared to non-contrast MRA, using catheter X-ray angiography (XRA) as the standard of reference (SOR). All MRA images were collected at 1.5 T in one imaging session for direct comparison, and XRA within 30 days. Sensitivity, specificity, and accuracy for diagnosing significant disease (stenosis {>=}50%) were calculated for MRA using three independent blinded readers. Patient safety was monitored for 72-96 h. Results: A total of 145 patients at 18 centers were enrolled and received gadofosveset; the 127 with complete efficacy data entered the primary efficacy analysis. Gadofosveset-enhanced MRA led to significant improvement (p < 0.01) in sensitivity (+25%, +26%, +42%), specificity (+23%, +25%, +29%), and accuracy (+23%, +28%, +29%) over non-enhanced MRA for the three readers. The rate of uninterpretable examinations decreased from 30% to less than 2%. There were no serious adverse events, and the most common adverse events were nausea, pruritis, and headache (8% each). No significant trends in clinical chemistry parameters, nor significant changes in serum creatinine, were found following administration of gadofosveset. Conclusion: In patients with known or suspected renal arterial disease, multi-phase gadofosveset-enhanced MRA significantly improves sensitivity, specificity, and accuracy versus non-enhanced MRA. Gadofosveset was safe and well tolerated in this patient population.

  18. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  19. [Feasibility of non-contrast enhanced magnetic resonance angiography for diagnosis of renal artery stenosis in elderly patients].

    Science.gov (United States)

    Xu, Xian; An, Ningyu; Chen, Suihui; Li, Xue; Jiang, Bo; Han, Shaojun; Liu, Xinqiu

    2014-01-01

    To evaluate the diagnostic efficacy of IFIR-FIESTA technique in detecting renal artery stenosis in elderly patients. Twenty-seven aged patients underwent both IFIR-FIESTA and 3D CE-MRA examinations. The imaging quality and renal artery stenosis grades were evaluated. Kappa test was used to assess the consistency between the two methods. With CE-MRA as the reference, the diagnostic sensitivity, specificity, accuracy, PPV and NPV for IFIR-FIESTA were calculated in detecting renal artery stenosis. The images by the two methods were 100% qualified for diagnosis, although the image quality of CE-MRA was significantly better. IFIR-FIESTA and CE-MRA showed excellent consistency in detecting renal artery stenosis. With CE-MRA as the reference, the diagnostic sensitivity, specificity, accuracy, PPV and NPV for IFIR-FIESTA were 97.1%, 100%, 98.1%, 100%, and 95% in detecting renal artery stenosis, respectively. IFIR-FIESTA is feasible as a routine examination for detecting renal artery stenosis in elderly patients.

  20. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  1. Single spin magnetic resonance

    Science.gov (United States)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  2. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to remain perfectly still and follow breath-holding instructions while the images are being recorded. If you ... Images related to Magnetic Resonance Imaging (MRI) - Head Videos related to Magnetic Resonance Imaging (MRI) - Head Sponsored ...

  6. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  7. Signs of hypervascularization at magnetic resonance imaging in bone metastases from renal cell carcinoma; Sinais de hipervascularizacao em imagens de ressonancia magnetica em metastases osseas de carcinoma de celulas renais

    Energy Technology Data Exchange (ETDEWEB)

    Feltrin, Leonir Terezinha; Cecin, Alexandre Oliveira; Mamere, Augusto Elias; Coelho, Rafael Darahem de Souza; Lucchesi, Fabiano Rubiao; Pinheiro, Marco Antonio Lopes [Hospital de Cancer de Barretos - Fundacao Pio XII, Barretos, SP (Brazil)], e-mail: leofeltrin@hotmail.com; Ferreira, Jose Renato [Hospital de Cancer de Barretos - Fundacao Pio XII, Barretos, SP (Brazil). Dept. de Radiologia; Trad, Clovis Simao [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina

    2009-05-15

    Objective: To evaluate the frequency of hypervascularization by visualizing vascular structures inside or around bone metastases from renal cell carcinoma. Materials and methods: Magnetic resonance imaging studies of 13 untreated patients with diagnosis of renal cell carcinoma and 15 metastatic bone lesions were retrospectively evaluated. Results: Signs of hypervascularization were found in 12 of the 15 bone lesions (80%), 6 of them localized in the lumbar spine, 3 in the hip, 3 in the thoracic spine, 1 in the ulna and 1 in the tibia. Conclusion: The high frequency of hypervascularization of bone metastases from renal cell carcinoma found in the present study may suggest that the renal etiology is a useful parameter in the evaluation of a usual clinical presentation of a single bone lesion with unknown primary neoplasm. (author)

  8. Renal dysplasia with single system ectopic ureter: Diagnosis using magnetic resonance urography and management with laparoscopic nephroureterectomy in pediatric age

    Directory of Open Access Journals (Sweden)

    Milind Joshi

    2009-01-01

    Conclusion : Single system ectopic ureter associated with congenital renal dysplasia is exceedingly rare. MRU is definitely the better investigation for the diagnosis of this condition as compared to the conventional radiological investigations. Laparoscopic nephroureterectomy is a very good procedure for the management of these cases.

  9. Use of magnetic resonance urography.

    Science.gov (United States)

    Klein, L T; Frager, D; Subramanium, A; Lowe, F C

    1998-10-01

    Magnetic resonance urography (MRU) is a new technique that uses heavily weighted T2 coronal images with fat suppression pulse. Urine appears white on MRU, resembling an intravenous urogram (IVU). Contrast agents are not necessary. This study describes the use of MRU in the diagnosis and treatment of patients with hematuria. One hundred six patients with microscopic or gross hematuria and 6 normal volunteers underwent MRU between 1992 and 1995. A modified, heavily weighted T2 technique with intravenous administration of furosemide and ureteral compression was used. Thirty-two patients had other imaging techniques as well for comparison. MRU provided high-resolution images in almost all cases; 73 (69%) had a normal MRU. Significant findings in the 33 patients with abnormalities included renal cysts in 17 (51%), renal cell carcinoma in 6 (18%), transitional cell carcinoma in 5 (15%), ureteropelvic junction obstruction in 3 (9%), and stones causing obstruction in 6 (18%). Five patients with renal failure also had good visualization of the entire urinary tract. MRU was comparable to other imaging modalities except in identifying nonobstructing calculi. MRU provides an alternative to conventional imaging of the urinary tract, especially in those patients who have contraindications to ionizing radiation and contrast agents. Improvements in resolution, technique, and cost have to be addressed before it can be used regularly in urologic practice.

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive medical ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  15. Contrast-enhanced magnetic resonance angiography for the detection of crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D.; Hiorns, Melanie P.; Olsen, Oystein E. [Hospital for Children NHS Trust, Department of Radiology, London (United Kingdom); Abhyankar, Aruna; Mushtaq, Imran [Hospital for Children NHS Trust, Department of Urology, London (United Kingdom)

    2007-04-15

    Crossing renal vessels (CRV) are associated with ureteropelvic junction (UPJ) obstruction, particularly when presentation is beyond the neonatal period. Their presence may influence surgical management. To evaluate the accuracy of contrast-enhanced magnetic resonance angiography (CE-MRA) in the identification of CRV in children requiring surgical treatment of symptomatic UPJ obstruction, against a gold standard of laparoscopic or open surgical findings. We reviewed CE-MRA studies (3-D T2-weighted turbo spin-echo and multiphase 3-D spoiled gradient echo following intravenous gadolinium administration) of 14 children, age range 6-15 years, performed prior to surgery for suspected CRV-related UPJ obstruction. Consensus reviews of the CE-MRA studies were compared with surgical findings. CE-MRA demonstrated CRV at the level of the obstruction in nine and no crossing vessels in five children. These were all verified intraoperatively ({chi}{sup 2} = 14.0; P < 0.001). In eight of the nine patients with CRV there was no evidence of intrinsic obstruction at surgery. In the remaining patient there was fibrosis of the upper ureter. CE-MRA is an accurate means of identifying CRV in children older than 6 years with symptomatic UPJ obstruction. (orig.)

  16. Parallel Magnetic Resonance Imaging

    CERN Document Server

    Uecker, Martin

    2015-01-01

    The main disadvantage of Magnetic Resonance Imaging (MRI) are its long scan times and, in consequence, its sensitivity to motion. Exploiting the complementary information from multiple receive coils, parallel imaging is able to recover images from under-sampled k-space data and to accelerate the measurement. Because parallel magnetic resonance imaging can be used to accelerate basically any imaging sequence it has many important applications. Parallel imaging brought a fundamental shift in image reconstruction: Image reconstruction changed from a simple direct Fourier transform to the solution of an ill-conditioned inverse problem. This work gives an overview of image reconstruction from the perspective of inverse problems. After introducing basic concepts such as regularization, discretization, and iterative reconstruction, advanced topics are discussed including algorithms for auto-calibration, the connection to approximation theory, and the combination with compressed sensing.

  17. In vivo quantification of VCAM-1 expression in renal ischemia reperfusion injury using non-invasive magnetic resonance molecular imaging.

    Directory of Open Access Journals (Sweden)

    Asim M Akhtar

    Full Text Available RATIONALE AND OBJECTIVE: Vascular cell adhesion molecule-1 (VCAM-1 is upregulated in ischemia reperfusion injury (IRI, persisting after restoration of blood flow. We hypothesized that microparticles of iron oxide targeting VCAM-1 (VCAM-MPIO would depict "ischemic memory" and enable in vivo assessment of VCAM-1 expression. METHODOLOGY AND FINDINGS: Mice subject to unilateral, transient (30 minutes renal ischemia and subsequent reperfusion received intravenous VCAM-MPIO (4.5 mg iron/kg body weight. Contrast agent bound rapidly (<30 minutes in IRI-kidneys and appeared as intensely low signal areas by MRI in vivo. Automated segmentation and quantification yielded MPIO contrast volumes of 5991±354×10(6 µm(3 in IRI vs. 87±7×10(6 µm(3 in kidneys with no surgical intervention (P<0.001; 90±8×10(6 µm(3 in IRI kidneys exposed to control (IgG-MPIO and 625±80×10(6 µm(3, in IRI kidneys pre-treated with a blocking dose of VCAM-1 antibody (P<0.001. In keeping with quantitative MRI data, VCAM-1 mRNA expression in IRI was 65-fold higher than in kidneys without surgical intervention (3.06±0.63 vs. 0.05±0.02, P<0.001. Indeed VCAM-1 mRNA expression and VCAM-MPIO contrast volume were highly correlated (R(2=0.901, P<0.01, indicating that quantification of contrast volume reflected renal VCAM-1 transcription. Serial imaging showed VCAM-MPIO accumulation at target within 30 minutes, persisting for ≥90 minutes, while unbound VCAM-MPIO was cleared rapidly from blood, with sequestration by mac-3 positive Kupffer cells in the liver and monocyte/macrophages in the spleen. CONCLUSIONS: (1 VCAM-MPIO detected VCAM-1 expression and defined its 3-dimensional distribution, revealing "ischemic memory" in renal IRI; (2 automated volumetric quantification of VCAM-MPIO accurately reflected tissue levels of VCAM-1 mRNA; and (3 VCAM-MPIO bound rapidly to target with active sequestration of unbound MPIO in the liver and spleen.

  18. Nuclear Magnetic Resonance Gyroscope

    Science.gov (United States)

    Larsen, Michael; Griffith, Robert; Bulatowicz, Michael

    2014-03-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation (NGC) has concluded the fourth and final phase of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. Traditional MEMS gyros utilize springs as an inherent part of the sensing mechanism, leading to bias and scale factor sensitivity to acceleration and vibration. As a result, they have not met performance expectations in real world environments and to date have been limited to tactical grade applications. The Nuclear Magnetic Resonance Gyroscope (NMRG) utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as an inertial reference for determining rotation. The nuclear spin precession rate sensitivity to acceleration and vibration is negligible for most applications. Therefore, the application of new micro and batch fabrication methods to NMRG technology holds great promise for navigation grade performance in a low cost and compact gyro. This presentation will describe the operational principles, design basics, and demonstrated performance of the NMRG including an overview of the NGC designs developed and demonstrated in the DARPA gyro development program.

  19. Urothelial carcinoma in a pyelocaliceal diverticulum discovered by magnetic resonance urography[

    Energy Technology Data Exchange (ETDEWEB)

    Akatsuka, Jun; Suzuki, Yasutomo; Hamasaki, Tsutomu; Kimura, Go; Kondo, Yukihiro, E-mail: s00-001@nms.ac.jp [Departments of Urology, Nippon Medical School, Bunkyo-ku, Tokyo (Japan)

    2014-03-15

    Neither computed tomography (CT) nor intravenous pyelography (IVP) alone can diagnose tumors of renal pelvic diverticula, but magnetic resonance urography (MRU) can obtain accurate preoperative information. (author)

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance ... if possible, or removed prior to the MRI scan. Because they can interfere with the magnetic field ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  2. Imaging oxygen metabolism with hyperpolarized magnetic resonance: a novel approach for the examination of cardiac and renal function.

    Science.gov (United States)

    Schroeder, Marie; Laustsen, Christoffer

    2017-02-28

    Every tissue in the body critically depends on meeting its energetic demands with sufficient oxygen supply. Oxygen supply/demand imbalances underlie the diseases that inflict the greatest socio-economic burden globally. The purpose of this review is to examine how hyperpolarized contrast media, used in combination with MR data acquisition methods, may advance our ability to assess oxygen metabolism non-invasively and thus improve management of clinical disease. We first introduce the concept of hyperpolarization and how hyperpolarized contrast media have been practically implemented to achieve translational and clinical research. We will then analyse how incorporating hyperpolarized contrast media could enable realization of unmet technical needs in clinical practice. We will focus on imaging cardiac and renal oxygen metabolism, as both organs have unique physiological demands to satisfy their requirements for tissue oxygenation, their dysfunction plays a fundamental role in society's most prevalent diseases, and each organ presents unique imaging challenges. It is our aim that this review attracts a multi-disciplinary audience and sparks collaborations that utilize an exciting, emergent technology to advance our ability to treat patients adversely affected by an oxygen supply/demand mismatch. © 2017 The Author(s).

  3. MRI (Magnetic Resonance Imager)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshinori [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1995-05-01

    MRI is a widely used diagnostic imaging modality because it has excellent diagnostic capabilities, is safe to use and generates images not affected by bone artifacts. Images are obtained by utilizing the phenomenon of Nuclear Magnetic Resonance (NMR) by which protons located in a static magnetic field absorb radio frequency (RF) pulses with a specific frequency and release a part of the energy as a NMR signal. Potentially MRI has the ability to provide functional and metabolic information (such as flow, temperature, diffusion, neuron activity) in addition to morphological information. This paper describes the imaging principles and provides a general outline of some applications: flow imaging, metabolite imaging and temperature imaging. (J.P.N.).

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ... Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  5. Dynamic contrast-enhanced magnetic resonance imaging in the early evaluation of anti-angiogenic therapy in metastatic renal cell carcinoma.

    Science.gov (United States)

    Panebianco, Valeria; Iacovelli, Roberto; Barchetti, Flavio; Altavilla, Amelia; Forte, Valerio; Sciarra, Alessandro; Cortesi, Enrico; Catalano, Carlo

    2013-12-01

    To evaluate the efficacy of dynamic contrast-enhanced magnetic resonance (DCE-MR) in the response to anti-angiogenic-targeted agents in patients with metastatic renal cell cancer (mRCC). Twenty-eight consecutive patients with sub-diaphragmatic metastases from mRCC were included in the protocol after signed informed consent. Baseline characteristics were collected and patients were first evaluated with a baseline computed tomography (CT) and DCE-MR, subsequently with a new DCE-MRI after 28 days of therapy and followed-up with CT until progression. Treatments were administered at standard doses. The changes of peak enhancement (ΔPE) and of the sum of longest tumor diameters (ΔLTD) were related to progression-free survival (PFS) and overall survival (OS). The median PFS was 11.4 months [95% Confidence Interval (CI): 7.9-14.7 months) and the parametric two-tailed Pearson's test showed a positive correlation between the median ΔPE and the median PFS (rp=0.809; p=0.015); no significant correlation was found between the median ΔLTD and the median PFS (rp=-0.446; p=0.27). The median OS was 23.3 months (95% CI: 13.6-33.0 months) and no significant correlation was found with the median ΔPE (rp=0.218; p=0.60) or with the median ΔLTD (rp=0.012; p=0.98). The ΔPE but not the ΔLTD was found to be significantly related to PFS; these preliminary results suggest extending the number of patients and investigating the possible relationship with other tumor characteristics and MRI parameters.

  6. Cardiovascular Magnetic Resonance Imaging

    Science.gov (United States)

    Pelc, Norbert

    2000-03-01

    Cardiovascular diseases are a major source of morbidity and mortality in the United States. Early detection of disease can often be used to improved outcomes, either through direct interventions (e.g. surgical corrections) or by causing the patient to modify his or her behavior (e.g. smoking cessation or dietary changes). Ideally, the detection process should be noninvasive (i.e. it should not be associated with significant risk). Magnetic Resonance Imaging (MRI) refers to the formation of images by localizing NMR signals, typically from protons in the body. As in other applications of NMR, a homogeneous static magnetic field ( ~0.5 to 4 T) is used to create ``longitudinal" magnetization. A magnetic field rotating at the Larmor frequency (proportional to the static field) excites spins, converting longitudinal magnetization to ``transverse" magnetization and generating a signal. Localization is performed using pulsed gradients in the static field. MRI can produce images of 2-D slices, 3-D volumes, time-resolved images of pseudo-periodic phenomena such as heart function, and even real-time imaging. It is also possible to acquire spatially localized NMR spectra. MRI has a number of advantages, but perhaps the most fundamental is the richness of the contrast mechanisms. Tissues can be differentiated by differences in proton density, NMR properties, and even flow or motion. We also have the ability to introduce substances that alter NMR signals. These contrast agents can be used to enhance vascular structures and measure perfusion. Cardiovascular MRI allows the reliable diagnosis of important conditions. It is possible to image the blood vessel tree, quantitate flow and perfusion, and image cardiac contraction. Fundamentally, the power of MRI as a diagnostic tool stems from the richness of the contrast mechanisms and the flexibility in control of imaging parameters.

  7. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles ... Videos related to Magnetic Resonance Imaging (MRI) - Head Sponsored ...

  9. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  10. Partially orthogonal resonators for magnetic resonance imaging

    Science.gov (United States)

    Chacon-Caldera, Jorge; Malzacher, Matthias; Schad, Lothar R.

    2017-02-01

    Resonators for signal reception in magnetic resonance are traditionally planar to restrict coil material and avoid coil losses. Here, we present a novel concept to model resonators partially in a plane with maximum sensitivity to the magnetic resonance signal and partially in an orthogonal plane with reduced signal sensitivity. Thus, properties of individual elements in coil arrays can be modified to optimize physical planar space and increase the sensitivity of the overall array. A particular case of the concept is implemented to decrease H-field destructive interferences in planar concentric in-phase arrays. An increase in signal to noise ratio of approximately 20% was achieved with two resonators placed over approximately the same planar area compared to common approaches at a target depth of 10 cm at 3 Tesla. Improved parallel imaging performance of this configuration is also demonstrated. The concept can be further used to increase coil density.

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  12. Magnetic resonance urography.

    Science.gov (United States)

    Leyendecker, John R; Gianini, John W

    2009-07-01

    Excellent contrast resolution and lack of ionizing radiation make magnetic resonance urography (MRU) a promising technique for noninvasively evaluating the entire urinary tract. While MRU currently lags behind CT urography (CTU) in spatial resolution and efficiency, new hardware and sequence developments have contributed to a resurgence of interest in MRU techniques. By combining unenhanced sequences with multiphase contrast-enhanced and excretory phase imaging, a comprehensive assessment of the kidneys, ureters, bladder, and surrounding structures is possible with image quality rivaling that obtained with other techniques. At the same time, formidable challenges remain to be overcome and further clinical validation is necessary before MRU can replace other forms of urography. In this article, we demonstrate the current potential of MRU to demonstrate a spectrum of urologic pathology involving the kidneys, ureters, and bladder while discussing the limitations and current status of this evolving technique.

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  14. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  15. Magnetic resonance imaging of the bone marrow following treatment with recombinant human erythropoietin in patients with end-stage renal disease

    DEFF Research Database (Denmark)

    Jensen, K E; Stenver, D; Jensen, M

    1990-01-01

    We used magnetic resonance imaging (MRI) to study vertebral bone marrow in hemodialysis patients during treatment with recombinant human erythropoietin (rHuEPO). We found changes in T1 relaxation times and image contrast within 14 days after starting treatment, before any response was seen in the...

  16. Monitoring the Progression of Renal Fibrosis by T2-weighted Signal Intensity and Diffusion Weighted Magnetic Resonance Imaging in Cisplatin induced Rat Models

    Institute of Scientific and Technical Information of China (English)

    Huan-Huan Wu; Hui-Ru Jia; Yi Zhang; Le Liu; Dong-Bo Xu; Hao-Ran Sun

    2015-01-01

    Background:Diffusion weighted imaging (DWI),with the applying of intravoxel incoherent motion model,has showed promising results in obtaining additional information about microperfusion and tubular flow associated with morphologic changes in chronic kidney diseases.The study aims to evaluate the potential of T2-weighted signal intensity (SI) and DWI with mono-and bi-exponential models to reflect the serial changes on cisplatin (CP) induced rat renal fibrosis models.Methods:Magnetic resonance exams were performed prior to and 2nd day,4th day,6th day,8th day,2nd week,3rd week and 4th week after CP injection at a 3.0T with an animal coil.Besides T2-weighted images (T2WI),DWI of 13 b values from 0 to 1500 s/mm2 was acquired.Apparent diffusion coefficient (ADC),fluid fraction f,pure diffusivity D and pseudodiffusivity D* values were calculated.The regions of interest were placed on cortex (CO),outer stripe of the outer medulla (OM) and inner stripe of the outer medulla (OM),parameters were measured and compared among different time points.Five rats were scarified at each time point for pathological examination.Results:OM revealed remarkable hyperintense and broadened before it became an obscure thread,while CO demonstrated moderate hyperintense and IM didn't show significant change on T2WI.On all three stripes,ADC values decreased firstly then kept increasing since the 4th day;f values decreased on all stripes; D values had a tendency to increase with fluctuations but the changes didn't achieve statistical significance; D* values increased at the 2nd day then tended to be steady thereafter.Pathological findings revealed tubules epitheliums swelling followed by inflammation cells infiltration,interstitial fibrosis was observed since the 2nd week.Conclusions:All of T2-weighted SI,ADC,and biexponential models parameters vary during fibrotic process; biexponential model is superior to monoexponential model in separating changes of microperfusion together with tubular flow

  17. Aortic dissection: magnetic resonance imaging.

    Science.gov (United States)

    Amparo, E G; Higgins, C B; Hricak, H; Sollitto, R

    1985-05-01

    Fifteen patients with suspected or known aortic dissection were imaged with magnetic resonance (MR). Thirteen of these patients were eventually shown to have dissection. In most instances the diagnosis was established by aortography and/or computed tomography (CT) prior to the MR study. Surgical proof (6/13) and/or aortographic proof (10/13) were available in 11/13 patients with aortic dissection. MR demonstrated the intimal flap and determined whether the dissection was type A or type B. In addition, MR: differentiated between the true and false lumens; determined the origins of the celiac, superior mesenteric, and renal arteries from the true or false lumen in the cases where the dissection extended into the abdominal aorta (8/12); allowed post-surgical surveillance of the dissection; and identified aortoannular ectasia in the three patients who had Marfan syndrome. In addition to the 13 cases with dissection, there were two cases in whom the diagnosis of dissection was excluded by MR. Our early experience suggests that MR can serve as the initial imaging test in clinically suspected cases of aortic dissection and that the information provided by MR is sufficient to manage many cases. Additionally, MR obviates the use of iodinated contrast media.

  18. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  19. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  20. Magnetic Resonance Imaging

    Science.gov (United States)

    ... metallic objects from being attracted by the powerful magnet of the MR system, you will typically receive ... teeth with magnetic keepers Other implants that involve magnets Medication patch (i.e., transdermal patch) that contains ...

  1. Magnetic resonance energy and topological resonance energy.

    Science.gov (United States)

    Aihara, Jun-Ichi

    2016-04-28

    Ring-current diamagnetism of a polycyclic π-system is closely associated with thermodynamic stability due to the individual circuits. Magnetic resonance energy (MRE), derived from the ring-current diamagnetic susceptibility, was explored in conjunction with graph-theoretically defined topological resonance energy (TRE). For many aromatic molecules, MRE is highly correlative with TRE with a correlation coefficient of 0.996. For all π-systems studied, MRE has the same sign as TRE. The only trouble with MRE may be that some antiaromatic and non-alternant species exhibit unusually large MRE-to-TRE ratios. This kind of difficulty can in principle be overcome by prior geometry-optimisation or by changing spin multiplicity. Apart from the semi-empirical resonance-theory resonance energy, MRE is considered as the first aromatic stabilisation energy (ASE) defined without referring to any hypothetical polyene reference.

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) ... ray, CT and ultrasound. top of page How is the procedure performed? MRI examinations may be performed ...

  4. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does ... the area being scanned include: Metallic spinal rod Plates, pins, screws, or metal mesh used to repair ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bore which can be more comfortable for larger size patients or patients with claustrophobia. Other MRI machines ... Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests and ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bore which can be more comfortable for larger size patients or patients with claustrophobia. Other MRI machines ... for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and ...

  7. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  14. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  15. Advances in magnetic resonance 4

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 4 deals with the relaxation, irradiation, and other dynamical effects that is specific to systems having resolved structure in their magnetic resonance spectra. This book discusses the anisotropic rotation of molecules in liquids by NMR quadrupolar relaxation; rotational diffusion constants; alternating linewidth effect; and theoretical formulations of the problem. The line shapes in high-resolution NMR; matrix representations of the equations of motion; matrix representations of the equations of motion; and intramolecular hydrogen bonds are also delibera

  16. Intraoperative magnetic resonance imaging.

    Science.gov (United States)

    Hall, Walter A; Truwit, Charles L

    2011-01-01

    Neurosurgeons have become reliant on image-guidance to perform safe and successful surgery both time-efficiently and cost-effectively. Neuronavigation typically involves either rigid (frame-based) or skull-mounted (frameless) stereotactic guidance derived from computed tomography (CT) or magnetic resonance imaging (MRI) that is obtained days or immediately before the planned surgical procedure. These systems do not accommodate for brain shift that is unavoidable once the cranium is opened and cerebrospinal fluid is lost. Intraoperative MRI (ioMRI) systems ranging in strength from 0.12 to 3 Tesla (T) have been developed in part because they afford neurosurgeons the opportunity to accommodate for brain shift during surgery. Other distinct advantages of ioMRI include the excellent soft tissue discrimination, the ability to view the surgical site in three dimensions, and the ability to "see" tumor beyond the surface visualization of the surgeon's eye, either with or without a surgical microscope. The enhanced ability to view the tumor being biopsied or resected allows the surgeon to choose a safe surgical corridor that avoids critical structures, maximizes the extent of the tumor resection, and confirms that an intraoperative hemorrhage has not resulted from surgery. Although all ioMRI systems allow for basic T1- and T2-weighted imaging, only high-field (>1.5 T) MRI systems are capable of MR spectroscopy (MRS), MR angiography (MRA), MR venography (MRV), diffusion-weighted imaging (DWI), and brain activation studies. By identifying vascular structures with MRA and MRV, it may be possible to prevent their inadvertent injury during surgery. Biopsying those areas of elevated phosphocholine on MRS may improve the diagnostic yield for brain biopsy. Mapping out eloquent brain function may influence the surgical path to a tumor being resected or biopsied. The optimal field strength for an ioMRI-guided surgical system and the best configuration for that system are as yet

  17. Magnetic resonance imaging; Imagerie par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Fontanel, F. [Centre Hospitalier, 40 - Mont-de -Marsan (France); Clerc, T. [Centre Hospitalier Universitaire, 76 - Rouen (France); Theolier, S. [Hospice Civils de Lyon, 69 - Lyon (France); Verdenet, J. [Centre Hospitalier Universitaire, 25 - Besancon (France)

    1997-04-01

    The last improvements in nuclear magnetic resonance imaging are detailed here, society by society with an expose of their different devices. In the future the different technological evolutions will be on a faster acquisition, allowing to reduce the examination time, on the development of a more acute cardiac imaging, of a functional neuro-imaging and an interactive imaging for intervention. With the contrast products, staying a longer time in the vascular area, the angiography will find its place. Finally, the studies on magnetic fields should allow to increase the volume to examine. (N.C.).

  18. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  19. Advances in magnetic resonance 5

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 5 deals with the interpretation of ESR spectra and provides descriptions of experimental apparatus. This book discusses the halogen hyperfine interactions; organic radicals in single crystals; pulsed-Fourier-transform nuclear magnetic resonance spectrometer; and inhomogenizer and decoupler. The spectrometers for multiple-pulse NMR; weak collision theory of relaxation in the rotating frame; and spin Hamiltonian for the electron spin resonance of irradiated organic single crystals are also deliberated. This text likewise covers the NMR in helium three and m

  20. Magnetic resonance imaging of the ductus arteriosus - case report

    Energy Technology Data Exchange (ETDEWEB)

    Yousry, T.; Bacherler, B.; Tiling, R.; Fink, U.; Werdan, K.

    1989-03-01

    In a female patient suffering from renal insufficiency in whom angiography could not be performed, it was possible to confirm the diagnosis of a ductus arteriosus (ductus of Botalli) by magnetic resonance imaging. The present case report shows that it is possible to visualise this congenital heart disease by MRI. This can be of importance especially if angiography cannot be performed (as in this case) because of renal insufficiency or because of contrast medium allergy.

  1. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  2. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  3. magnetic resonance imaging,etc.

    Institute of Scientific and Technical Information of China (English)

    张福基

    1998-01-01

    magnetic resonance imaging n.[1984] a noninvasive diagnostic technique that produces computerized images of internal body tissues and is based on nuclear magnetic resonance of atoms within he body induced by the application of radio waves磁共振成像(指一种非侵害 性诊断技术,能生成内部身体组织的计算机化影像,其依据是应用无线电波 感生体内原子并使之产磁共振)

  4. Advances in magnetic resonance 8

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 8 describes the magnetic resonance in spin polarization and saturation transfer. This book discusses the theory of chemically induced dynamic spin polarization; basic results for the radical-pair mechanism; and optical spin polarization in molecular crystals. The theory of optical electronic polarization (OEP); NMR in flowing systems; and applications of NMR in a flowing liquid are also elaborated. This text likewise covers the saturation transfer spectroscopy; studies of spin labels in the intermediate and fast motion regions; and spin-density matrix and

  5. The Feasibility of Magnetic Resonance Imaging for Quantification of Liver, Pancreas, Spleen, Vertebral Bone Marrow, and Renal Cortex R2* and Proton Density Fat Fraction in Transfusion-Related Iron Overload.

    Science.gov (United States)

    İdilman, İlkay S; Gümrük, Fatma; Haliloğlu, Mithat; Karçaaltıncaba, Muşturay

    2016-03-05

    We aimed to evaluate the feasibility of quantification of liver, pancreas, spleen, vertebral bone marrow, and renal cortex R2* and magnetic resonance imaging-proton density fat fraction (MRI-PDFF) and to evaluate the correlations among them in patients with transfusion-related iron overload. A total of 9 patients (5 boys, 4 girls) who were referred to our clinic with suspicion of hepatic iron overload were included in this study. All patients underwent T1-independent volumetric multi-echo gradient-echo imaging with T2* correction and spectral fat modeling. MRI examinations were performed on a 1.5 T MRI system. All patients had hepatic iron overload. Severe hepatic iron overload was recorded in 5/9 patients (56%), and when we evaluated the PDFF maps of these patients, we observed an extensive patchy artifact in the liver in 4 of 5 patients (R2* greater than 671 Hz). When we performed MRI-PDFF measurements despite these artifacts, we observed artifactual high MRI-PDFF values. There was a close correlation between average pancreas R2* and average pancreas MRI-PDFF (p=0.003, r=0.860). There was a significant correlation between liver R2* and average pancreas R2* (p=0.021, r=0.747), liver R2* and renal cortex R2* (p=0.020, r=0.750), and average pancreas R2* and renal cortex R2* (p=0.003, r=0.858). There was a significant negative correlation between vertebral bone marrow R2* and age (p=0.018, r=-0.759). High iron content of the liver, especially with a T2* value shorter than the first echo time can spoil the efficacy of PDFF calculation. Fat deposition in the pancreas is accompanied by pancreatic iron overload. There is a significant correlation between hepatic siderosis and pancreatic siderosis. Renal cortical and pancreatic siderosis are correlated, too.

  6. Diagnostic accuracy of contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation.

    Science.gov (United States)

    Kim, Jae Heon; Sun, Hwa Yeon; Hwang, Jiyoung; Hong, Seong Sook; Cho, Yong Jin; Doo, Seung Whan; Yang, Won Jae; Song, Yun Seob

    2016-10-12

    The aim of this study was to investigate the diagnostic accuracy of contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of small renal masses in real practice. Contrast-enhanced CT and MRI were performed between February 2008 and February 2013 on 68 patients who had suspected small (≤4 cm) renal cell carcinoma (RCC) based on ultrasonographic measurements. CT and MRI radiographs were reviewed, and the findings of small renal masses were re-categorized into five dichotomized scales by the same two radiologists who had interpreted the original images. Receiver operating characteristics curve analysis was performed, and sensitivity and specificity were determined. Among the 68 patients, 60 (88.2 %) had RCC and eight had benign disease. The diagnostic accuracy rates of contrast-enhanced CT and MRI were 79.41 and 88.23 %, respectively. Diagnostic accuracy was greater when using contrast-enhanced MRI because too many masses (67.6 %) were characterized as "4 (probably solid cancer) or 5 (definitely solid cancer)." The sensitivity of contrast-enhanced CT and MRI for predicting RCC were 79.7 and 88.1 %, respectively. The specificities of contrast-enhanced CT and MRI for predicting RCC were 44.4 and 33.3 %, respectively. Fourteen diagnoses (20.5 %) were missed or inconsistent compared with the final pathological diagnoses. One appropriate nephroureterectomy and five unnecessary percutaneous biopsies were performed for RCC. Seven unnecessary partial nephrectomies were performed for benign disease. Although contrast-enhanced CT and MRI showed high sensitivity for detecting small renal masses, specificity remained low.

  7. Magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bushong, S.C.

    1988-01-01

    This book introduces the fundamentals and principles of MRI, its capabilities and various techniques of application. Appropriate background for MRI is provided, including basic nuclear magnetic phenomena, modifications required for imaging, the current state of clinical knowledge and a survey of the future potential for in vivo MRI.

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... this is the case, you will be given instructions for your child about not eating or drinking several hours prior ... MRI) Safety Contrast Materials Children and Radiation Safety Videos related to Children’s (Pediatric) Magnetic Resonance Imaging Sponsored by Please note ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... mail: Area code: Phone no: Thank you! ... Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... are the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is ... ray, CT and ultrasound. top of page How is the procedure performed? MRI examinations may be performed ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... E-mail: Area code: Phone no: Thank you! Images × Image Gallery Radiologist prepping patient for magnetic resonance imaging ( ... address): From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... E-mail: Area code: Phone no: Thank you! Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View full ... address): From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your ...

  13. Magnetic Resonance Image Wavelet Enhancer

    Science.gov (United States)

    2007-11-02

    1Departamento de Ingenieria Electrica, UAM Iztapalapa, Mexico−DF, 09340, Mexico email:arog@xanum.uam.mx. Magnetic Resonance Centre, School of Physics...Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Departamento de Ingenieria Electrica, UAM Iztapalapa, Mexico-DF

  14. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance ... allergic reaction than iodinated contrast material. Tell your doctor about any health problems, recent surgeries or allergies ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ...

  1. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  2. Magnetic resonance urography in pediatric urology.

    Science.gov (United States)

    Cerwinka, Wolfgang H; Kirsch, Andrew J

    2010-07-01

    Magnetic resonance urography (MRU) has evolved into an effective imaging tool for the evaluation of the urinary tract in children. The goal of this article is to describe current techniques and applications of MRU and to review recent advances. MRU is most commonly applied to the evaluation of hydronephrosis and provides valuable insight into a wide range of obstructive uropathies. MRU was shown to be superior to renal scintigraphy for the diagnosis of pyelonephritis and renal scarring. The use of MRU for the assessment of urolithiasis, vesicoureteral reflux, renal trauma, and fetal urinary tract abnormalities is limited and technical refinements are required. Judicious use of gadolinium-based contrast agents in patients at risk for nephrogenic systemic fibrosis was recently shown to avoid new occurrences. Potential future applications include virtual endoscopy and MRU-guided procedures. MRU has the potential to revolutionize imaging of the urinary tract in children. It integrates exquisite anatomical information with a variety of functional data and avoids ionizing radiation. MRU is increasingly employed as a problem solver when conventional imaging studies remain inconclusive and its growing application will likely improve availability and cost in the future.

  3. 慢性肾衰病人椎体骨质变化的MRS研究进展%Progress of magnetic resonance spectroscopy in chronic renal failure patients with vertebral bone change

    Institute of Scientific and Technical Information of China (English)

    高才良; 董国礼; 曾南林

    2013-01-01

    慢性肾功能衰竭病人的骨质改变目前已成为影响其生存质量的突出问题.如何更好地评估其骨质变化情况,进而早期进行有效干预及治疗已成为重要的研究内容.MR波谱成像(MRS)作为MR功能成像的一种已成功应用于中枢神经系统、乳腺及前列腺等的检测,而在评价骨质变化中的价值亦在研究中.现就MRS评估慢性肾功能衰竭病人椎体骨质变化情况予以综述.%Bone changes caused by kidney diseases affect the quality of life in the patients with chronic renal failure.How to improve evaluation of the bone change,and consequently start early intervention and treatment is an important topic.Magnetic resonance spectroscopy (MRS) has been successfully used in the evaluations of central nervous system,breast and prostate,etc.Evaluation of bone changes with MRS is under studied.This article reviewed the MRS in evaluation of vertebral body bone changes in patients with chronic renal failure.

  4. Urothelial carcinoma in a pyelocaliceal diverticulum discovered by magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Jun Akatsuka

    2014-04-01

    Full Text Available Neither computed tomography (CT nor intravenous pyelography (IVP alone can diagnose tumors of renal pelvic diverticula, but magnetic resonance urography (MRU can obtain accurate preoperative information.

  5. Resonant magnetic fields from inflation

    CERN Document Server

    Byrnes, Christian T; Jain, Rajeev Kumar; Urban, Federico R

    2012-01-01

    We propose a novel scenario to generate primordial magnetic fields during inflation induced by an oscillating coupling of the electromagnetic field to the inflaton. This resonant mechanism has two key advantages over previous proposals. First of all, it generates a narrow band of magnetic fields at any required wavelength, thereby allaying the usual problem of a strongly blue spectrum and its associated backreaction. Secondly, it avoids the need for a strong coupling as the coupling is oscillating rather than growing or decaying exponentially. Despite these major advantages, we find that the backreaction is still far too large during inflation if the generated magnetic fields are required to have a strength of ${\\cal O}(10^{-15}\\, \\Gauss)$ today on observationally interesting scales. We provide a more general no-go argument, proving that this problem will apply to any model in which the magnetic fields are generated on subhorizon scales and freeze after horizon crossing.

  6. Magnetic resonance tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.

    1985-12-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness.

  7. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to char...... a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging....

  8. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  9. Progresses of functional magnetic resonance imaging in renal ifbrosis%肾纤维化功能性MRI的研究进展

    Institute of Scientific and Technical Information of China (English)

    李琼; 李震

    2015-01-01

    肾纤维化可导致肾功能衰竭,是终末期慢性肾病常见的结局,也是肾移植失败的最常见原因。因此,肾纤维化的程度与患者预后密切相关。临床上检测肾纤维化造成肾功能不全的方法有很多,但是目前缺乏一种活体无创性动态监测肾纤维化的可靠手段。fMRI在检测肾功能、评估肾纤维化程度方面近来越来越受到重视。作者回顾和分析了过去几年肾脏的几种fMRI在肾纤维化这一领域的发展。%Renal fibrosis can lead to renal failure, it is a common outcome of end-stage chronic kidney disease, and the most common cause of kidney transplant failure. Therefore, the degree of renal ifbrosis is closely related to the prognosis and patients. Although some methods can inspect renal ifbrosis and renal insufifciency well, none of them can non-invasively detect renal ifbrosis in vivo perfectly. Recently, more and more researches about renal fibrosis and renal insufficiency diagnosis by functional MRI were reported. This paper reviews and analyzes some functional MRI progresses about renal ifbrosis in the past few years.

  10. Preoperative planning of renal transplantation: a comparison of non-contrast-enhanced ultrasonography, computed tomography, and magnetic resonance angiography with observations from surgery.

    Science.gov (United States)

    Blankholm, Anne Dorte; Pedersen, Bodil G; Stausbøl-Grøn, Brian; Andersen, Gratien; Hørlyck, Arne; Østrat, Ernst Ø; Laustsen, Sussie; Ringgaard, Steffen

    2015-12-01

    Many candidates for kidney transplantation need to undergo vessel examination before the transplantation procedure. To identify the optimal preoperative modality for the examination of vessel status without the use of contrast agents in kidney transplant candidates. Fifty-three consecutive patients were examined and 31 patients were transplanted. Ultrasonography (US), non-contrast-enhanced computed tomography (NCCT), and non-contrast-enhanced magnetic resonance angiography (NCMRA) were compared using inspection during kidney transplantation (TX) as a reference standard. The sensitivity and specificity to severe arteriosclerotic changes and the accuracy were calculated. Kappa statistics were used to assess the agreement between TX and the different examination modalities, and McNemar's test was used to test for significant differences. US had higher sensitivity (1.0) and better agreement with observations from surgery (k = 0.89) than both NCCT (sensitivity = 0.60; k = 0.72) and NCMRA (sensitivity = 0.20; k = 0.30). No significant difference was found between TX and US (P = 0.3173) or TX and NCCT (P = 0.1573), but there was a significant difference between TX and NCMRA (P = 0.0455). US was inconclusive in 20% of cases, and the internal iliac artery could not be visualized in 69% of cases. Either US or NCCT can be used as the preferred preoperative imaging modality to examine vessel status before kidney transplantation, but a combination of the two is preferable. NCMRA should not be used as the sole imaging modality for preoperative imaging before kidney transplantation because of its low sensitivity in detecting severe arteriosclerotic disease without the presence of stenosis. © The Foundation Acta Radiologica 2014.

  11. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  12. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  13. Magnetic resonance imaging of hemochromatosis arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); Buff, B. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); McCarthy, C. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); MacMathuana, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Gilligan, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Ennis, J.T. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland)

    1994-10-01

    This study was undertaken to compare plain film radiography and magnetic resonance imaging in the assessment of hemochromatosis arthropathy of the knees of ten patients with a biopsy-proven diagnosis. Both modalities enabled visualisation of bony degenerative changes; magnetic resonance imaging enabled additional visualization of deformity of both cartilage and menisci. Magnetic resonance imaging failed reliably to confirm the presence of intra-articular iron in the patients studied. No correlation was observed between synovial fluid magnetic resonance signal values, corresponding serum ferritin levels, or the severity of the observed degenerative changes. (orig.)

  14. Diagnostic accuracy of segmental enhancement inversion for the diagnosis of renal oncocytoma using biphasic computed tomography (CT) and multiphase contrast-enhanced magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schieda, Nicola; McInnes, Matthew D.F. [The University of Ottawa, The Ottawa Hospital, Department of Medical Imaging, Ottawa, Ontario (Canada); Al-Subhi, Maali; Flood, Trevor A.; El-Khodary, Mohammed [The University of Ottawa, The Ottawa Hospital, Department of Anatomical Pathology, Ottawa, ON (Canada)

    2014-11-15

    Segmental enhancement inversion (SEI) is a controversial imaging finding reportedly specific for the diagnosis of renal oncocytoma. The purpose of this study was to re-evaluate SEI using biphasic CT and multiphase MRI. With research ethics board approval, a retrospective analysis of patients with resection or biopsy of oncocytoma or chromophobe renal cell carcinoma (Ch-RCC) between 2008-2012 was performed. Twenty-four patients with oncocytoma and 13 patients with Ch-RCC underwent CT, while 13 patients with oncocytoma and 10 patients with Ch-RCC underwent MRI. Two blinded radiologists reviewed the CT and MRI studies independently in separate sessions to assess for SEI. A third radiologist established consensus. Interobserver variability was calculated and diagnostic accuracy was compared using ROC and the Fisher exact test. There was no difference in detection of SEI between oncocytoma and Ch-RCC at CT [both readers (p = 0.65, 0.5) and consensus review (p = 0.29)] or MRI [both readers (p = 0.64, 0.74) and consensus review (p = 0.53)]. The interobserver variability at CT (K = 0.28-0.33) and MRI (K = 0.25-0.44) was fair. The sensitivity and specificity for diagnosis of oncocytoma were 21 % and 92 % at CT and 15 % and 90 % at MRI. SEI is not useful for the diagnosis of renal oncocytoma with CT or MRI. (orig.)

  15. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Spithoven, E.M.; Meijer, E.; Boertien, W.E.; Gaillard, C.A.J.M.; Jong, P.E. de; Gansevoort, R.T. [University of Groningen, Department of Nephrology, Community and Occupational Medicine, University Medical Center Groningen, PO Box 30.001, RB Groningen (Netherlands); Borns, C.; Kappert, P.; Greuter, M.J.W.; Jagt, E. van der [University of Groningen, Department of Radiology, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands); Vart, P. [University of Groningen, Department of Health Sciences, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands)

    2016-03-15

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBF{sub MRI}) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. First, we validated RBF{sub MRI} measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBF{sub MRI}. After validation, we measured RBF{sub MRI} in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBF{sub MRI} and RBF measured by continuous hippuran infusion. The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBF{sub MRI} measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBF{sub MRI} compared to RBF{sub Hip,} whereas in subjects with lower eGFRs, this was significantly less for RBF{sub MRI}. Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. (orig.)

  16. Magnetic Resonance Imaging of Electrolysis.

    Science.gov (United States)

    Meir, Arie; Hjouj, Mohammad; Rubinsky, Liel; Rubinsky, Boris

    2015-01-01

    This study explores the hypothesis that Magnetic Resonance Imaging (MRI) can image the process of electrolysis by detecting pH fronts. The study has relevance to real time control of cell ablation with electrolysis. To investigate the hypothesis we compare the following MR imaging sequences: T1 weighted, T2 weighted and Proton Density (PD), with optical images acquired using pH-sensitive dyes embedded in a physiological saline agar solution phantom treated with electrolysis and discrete measurements with a pH microprobe. We further demonstrate the biological relevance of our work using a bacterial E. Coli model, grown on the phantom. The results demonstrate the ability of MRI to image electrolysis produced pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E. Coli model grown on the phantom. The results are promising and invite further experimental research. PMID:25659942

  17. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  18. Chemical Principles Revisited. Proton Magnetic Resonance Spectroscopy.

    Science.gov (United States)

    McQuarrie, Donald A.

    1988-01-01

    Discusses how to interpret nuclear magnetic resonance (NMR) spectra and how to use them to determine molecular structures. This discussion is limited to spectra that are a result of observation of only the protons in a molecule. This type is called proton magnetic resonance (PMR) spectra. (CW)

  19. Enhancement of Magnetic Resonance Imaging with Metasurfaces

    NARCIS (Netherlands)

    Slobozhanyuk, Alexey P; Poddubny, Alexander N; Raaijmakers, AJE; van den Berg, CAT; Kozachenko, Alexander V; Dubrovina, Irina A; Melchakova, Irina V; Kivshar, Yuri S; Belov, Pavel A

    2016-01-01

    It is revealed that the unique properties of ultrathin metasurface resonators can improve magnetic resonance imaging dramatically. A metasurface formed when an array of metallic wires is placed inside a scanner under the studied object and a substantial enhancement of the radio-frequency magnetic

  20. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  1. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  2. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  3. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled.

  4. Comparison of the iron oxide-based blood-pool contrast medium VSOP-C184 with gadopentetate dimeglumine for first-pass magnetic resonance angiography of the aorta and renal arteries in pigs.

    Science.gov (United States)

    Schnorr, Jörg; Wagner, Susanne; Abramjuk, Claudia; Wojner, Ines; Schink, Tania; Kroencke, Thomas J; Schellenberger, Eyk; Hamm, Bernd; Pilgrimm, Herbert; Taupitz, Matthias

    2004-09-01

    VSOP-C184 at a dose of 0.045 mmol Fe/kg has been shown to be an efficient blood pool contrast medium for equilibrium magnetic resonance angiography (MRA) that can be administered as a bolus. The present study was performed to determine whether VSOP-C184 is also suitable for first-pass MRA. Fifteen MRA examinations at 1.5 T were performed in minipigs using a fast 3D fast low-angle shot (FLASH) sequence (repetition time = 4.5 ms, echo time = 1.7 ms, excitation angle = 25 degrees, matrix 256, body phased-array coil). The citrate-stabilized iron oxide preparation VSOP-C184 was investigated (total particle diameter: 7.0 +/- 0.15 nm; core size: 4 nm) and compared with gadopentetate dimeglumine (Gd-DTPA). The following doses were tested: VSOP-C184: 0.015, 0.025, and 0.035 mmol Fe/kg; Gd-DTPA: 0.1 and 0.2 mmol Gd/kg; n = 3 examinations/dose. Data were analyzed quantitatively (signal enhancement (ENH) and vessel edge definition (VED)) and qualitatively. First-pass MRA using the 3 doses of VSOP-C184 yielded the following ENH: aorta: 9.4 +/- 2.6; 12.31 +/- 1.2; 16.53 +/- 1.7; renal arteries: 7.6 +/- 2.2; 9.9 +/- 1.0; 13.2 +/- 0.5. The values for the 2 doses of Gd-DTPA were aorta: 12.9 +/- 1.0; 16.8 +/- 2.2; renal arteries: 11.2 +/- 1.23; 11.3 +/- 1.7. VED for the 3 doses of VSOP-C184 was aorta: 106.3 +/- 31.0; 135.3 +/- 58.8; 141.3 +/- 71.0; renal arteries: 102.2 +/- 24.3; 146.8 +/- 63.0; 126.9 +/- 37.6 and for the 2 doses of Gd-DTPA, aorta: 157.2 +/- 47.8; 164.2 +/- 36.8; renal arteries: 165.9 +/- 30.4; 170.3 +/- 38.2 respectively. The differences between VSOP-C184 and Gd-DTPA are clinically not relevant and statistically not significant (p > or = .05). Qualitative evaluation of image quality, contrast, and delineation of vessels showed the results obtained with VSOP-C184 at doses of 0.025 and 0.035 mmol Fe/kg to be similar to those of Gd-DTPA at 0.1 and 0.2 mmol Gd/kg. VSOP-C184 is suitable for first-pass MRA at doses of 0.025 and 0.035 mmol Fe/kg and thus, in addition to

  5. Evaluation of treatment response and resistance in metastatic renal cell cancer (mRCC) using integrated (18)F-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography/magnetic resonance imaging (PET/MRI); The REMAP study.

    Science.gov (United States)

    Kelly-Morland, Christian; Rudman, Sarah; Nathan, Paul; Mallett, Susan; Montana, Giovanni; Cook, Gary; Goh, Vicky

    2017-06-02

    Tyrosine kinase inhibitors are the first line standard of care for treatment of metastatic renal cell carcinoma (RCC). Accurate response assessment in the setting of antiangiogenic therapies remains suboptimal as standard size-related response criteria do not necessarily accurately reflect clinical benefit, as they may be less pronounced or occur later in therapy than devascularisation. The challenge for imaging is providing timely assessment of disease status allowing therapies to be tailored to ensure ongoing clinical benefit. We propose that combined assessment of morphological, physiological and metabolic imaging parameters using 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ((18)F-FDG PET/MRI) will better reflect disease behaviour, improving assessment of response/non-response/relapse. The REMAP study is a single-centre prospective observational study. Eligible patients with metastatic renal cell carcinoma, planned for systemic therapy, with at least 2 lesions will undergo an integrated (18)F-FDG PET and MRI whole body imaging with diffusion weighted and contrast-enhanced multiphasic as well as standard anatomical MRI sequences at baseline, 12 weeks and 24 weeks of systemic therapy allowing (18)F-FDG standardised uptake value (SUV), apparent diffusion co-efficient (ADC) and normalised signal intensity (SI) parameters to be obtained. Standard of care contrast-enhanced computed tomography CT scans will be performed at equivalent time-points. CT response categorisation will be performed using RECIST 1.1 and alternative (modified)Choi and MASS criteria. The reference standard for disease status will be by consensus panel taking into account clinical, biochemical and conventional imaging parameters. Intra- and inter-tumoural heterogeneity in vascular, diffusion and metabolic response/non-response will be assessed by image texture analysis. Imaging will also inform the development of computational methods for automated disease

  6. Changes of the cerebral metabolite patterns in patients undergoing hemodialysis due to chronic renal failure: evaluation with proton magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Hye Won; Yu, Hyeon; Yu, Soo Jeong; Kim, Gi Hyeon [Chung-Ang University Medical Center, College of Medicine, Seoul (Korea, Republic of)

    2007-08-15

    We wanted to evaluate the cerebral metabolites in patients with chronic renal failure (CRF) and who were undergoing hemodialysis by performing proton MR spectroscopy and were wanted to evaluate the correlation between the changes in the cerebral metabolite ratios and the duration after starting the initial hemodialysis. Proton MR spectroscopy was performed in 15 patients with CRF and who were undergoing hemodialysis and in ten healthy volunteers. The changes in N-acetylaspartate (NAA), choline-containing compounds (Cho), myo-inositol (Myo), glutamine/glutamate complex (Glx), and creatine (Cr) were analyzed. MR spectroscopy was performed before and after hemodialysis. For the patients with CRF before hemodialysis, the Cho/Cr ratio in the gray matter ({rho} < 0.001) and the Myo/Cr ratio in both the gray and white matter ({rho} < 0.01) were significantly elevated compared with those in the control subjects. For the patients with CRF after hemodialysis, their Cho/Cr ratios were significantly reduced in both the gray and white matter compared with that before hemodialysis ({rho} < 0.05). There was a significant positive correlation between the Cho/Cr ratio and serum Cr in the gray matter of CRF patients after hemodialysis (r = 0.54, {rho} < 0.05). The cerebral metabolite ratios were not significantly correlated with the duration after starting the initial hemodialysis. The cerebral metabolite patterns are significantly different between the patients with CRF and who are undergoing hemodialysis and the normal controls. The cerebral metabolite ratios are not significantly correlated with the duration after starting the initial hemodialysis.

  7. Nuclear magnetic resonance. Tomography of tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    Ethier, R.; Melanson, D.; Peters, T.M. (Montreal Neurological Inst., Quebec (Canada))

    1983-10-01

    Ten years following computerized tomography, a new technique called nuclear magnetic resonance revolutionizes the field of diagnostic imaging. A major advantage of nuclear magnetic resonance is that the danger of radiation is non-existent as compared to computerized tomography. When parts of the human body are subject to radio-frequencies while in a fixed magnetic field, its most detailed structures are revealed. The quality of images, the applications, as well as the indications are forever increasing. Images obtained at the level of the brain and spinal cord through nuclear magnetic resonance supercede those obtained through computerized tomography. Hence, it is most likely that myelography, along with pneumoencephalography will be eliminated as a diagnostic means. It is without a doubt that nuclear magnetic resonance is tomorrow's computerized tomography.

  8. Magnetic resonance images of hematospermia

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Norio; Miki, Kenta; Kato, Nobuki; Furuta, Nozomu; Ohishi, Yukihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Kondo, Naoya; Tashiro, Kazuya

    1998-12-01

    We performed MRI (magnetic resonance imaging) in the pelvic region of 70 cases with hematospermia and conducted a study on the abnormal MRI findings to which hematospermia could be attributed. We conducted a study on the morphological anomaly and change in the signal intensity in the prostate gland and of the seminal vesicle as well as on the presence or absence of dilation in the plexus venous surrounding the deferent duct or the prostate gland out of the abnormal MRI findings. As for the seminal vesicle, the patients whose seminal vesicle was seen in higher intensity than the prostate gland in T1 weighted images were diagnosed as having hemorrhagic focus and the patients whose seminal vesicle was seen in low intensity both in T1 and T2 weighted images were diagnosed as having fibrosis caused by chronic inflammation. Abnormal MRI findings were seen in 40 out of the 70 cases (57%). Anomaly in the prostate gland was indicated in 6 (9%) cases. Abnormality in the seminal vesicle was indicated in 30 cases (43%) including hemorrhage of seminal vesicle in 25 cases, chronic inflammation in five cases and cyst of seminal vesicle in one case. In conducting an examination of the patients with hematospermia, MRI is the nonivasive and reproducible method and it is possible to identify the hemorrhagic region. Therefore, MRI is thought to be useful to identify the causal organs of hematospermia. (author)

  9. Magnetic resonance in Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, G.; Scialfa, G.; Biondi, A.; Landoni, L.; Caputo, D.; Cazzullo, C.L.

    1986-07-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres.

  10. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  11. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  12. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... I-131 Therapy Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... pictures of the major blood vessels throughout your body. It may be performed with or without contrast ...

  13. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  14. single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    2011-03-03

    Mar 3, 2011 ... magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- ..... this study, it is important to note that there were distinct differences in the .... Applications of MRS in the. 13. evaluation ...

  15. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  16. Magnetic-resonance velocity mapping of the central circulation

    DEFF Research Database (Denmark)

    Søndergaard, Lise

    1994-01-01

    In magnetic-resonance (MR) velocity mapping there exists a linear relationship between the velocity and signal in each element of a tomographic image. The technique can be used for quantitative measurements of linear velocities (m s-1) and flow rates (1 min-1). By using cinematographic images...... the flow profile during the cardiac cycle can be determined. This allows quantification of forward flow, regurgitant volume and regurgitant fraction in cases of heart-valve insufficiency. In valvular stenosis the transvalvular pressure gradient and valve area can be determined. Magnetic-resonance velocity...... mapping may also provide information about diastolic function of left ventricular function. Together with other MR imaging techniques, velocity mapping gives an accurate assessment of the severity of aortic dissection. Recent studies indicate that MR velocity mapping provides quantification of renal blood...

  17. Caroli's disease: magnetic resonance imaging features

    Energy Technology Data Exchange (ETDEWEB)

    Guy, France; Cognet, Francois; Dranssart, Marie; Cercueil, Jean-Pierre; Conciatori, Laurent; Krause, Denis [Department of Radiology and Imaging, Dijon Le Bocage University Hospital, 2 Blvd. Marechal de Lattre de Tassigny, BP 1542, 21034 Dijon Cedex (France)

    2002-11-01

    Our objective was to describe the main aspects of MR imaging in Caroli's disease. Magnetic resonance cholangiography with a dynamic contrast-enhanced study was performed in nine patients with Caroli's disease. Bile duct abnormalities, lithiasis, dot signs, hepatic enhancement, renal abnormalities, and evidence of portal hypertension were evaluated. Three MR imaging patterns of Caroli's disease were found. In all but two patients, MR imaging findings were sufficient to confirm the diagnosis. Moreover, MR imaging provided information about the severity, location, and extent of liver involvement. This information was useful in planning the best therapeutic strategy. Magnetic resonance cholangiography with a dynamic contrast-enhanced study is a good screening tool for Caroli's disease. Direct cholangiography should be reserved for confirming doubtful cases. (orig.)

  18. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  19. Enhancement of artificial magnetism via resonant bianisotropy

    CERN Document Server

    Markovich, Dmitry; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2015-01-01

    All-dielectric "magnetic light" nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here a new approach for increasing magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer nanoantenna. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of magnetic polarizability, tailoring the later in the dynamical range of 100 % and enhancement up to 36 % relative to performances of standalone spherical particles....

  20. Torque-mixing Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Losby, Joseph; Fani Sani, Fatemeh; Grandmont, Dylan; Diao, Zhu; Belov, Miro; Burgess, Jacob; Compton, Shawn; Hiebert, Wayne; Vick, Doug; Mohammad, Kaveh; Salimi, Elham; Bridges, Gregory; Thomson, Douglas; Freeman, Mark

    A universal, mechanical torque method for magnetic resonance spectroscopy is presented. In analogy to resonance detection by induction, a signal proportional to the transverse component of a precessing dipole moment can be measured as a pure mechanical torque in broadband, frequency-swept spectroscopy. Comprehensive electron spin resonance of a single-crystal, mesoscopic yttrium iron garnet disk at room temperature are presented to demonstrate the method. The rich detail allows analysis of even complex 3D spin textures.

  1. Magnetic Resonance Imaging (MRI) - Spine

    Science.gov (United States)

    ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  9. Functional assessment of transplanted kidneys with magnetic resonance imaging.

    Science.gov (United States)

    Wang, Yu-Ting; Li, Ying-Chun; Yin, Long-Lin; Pu, Hong; Chen, Jia-Yuan

    2015-10-28

    Kidney transplantation has emerged as the treatment of choice for many patients with end-stage renal disease, which is a significant cause of morbidity and mortality. Given the shortage of clinically available donor kidneys and the significant incidence of allograft dysfunction, a noninvasive and accurate assessment of the allograft renal function is critical for postoperative management. Prompt diagnosis of graft dysfunction facilitates clinical intervention of kidneys with salvageable function. New advances in magnetic resonance imaging (MRI) technology have enabled the calculation of various renal parameters that were previously not feasible to measure noninvasively. Diffusion-weighted imaging provides information on renal diffusion and perfusion simultaneously, with quantification by the apparent diffusion coefficient, the decrease of which reflects renal function impairment. Diffusion-tensor imaging accounts for the directionality of molecular motion and measures fractional anisotropy of the kidneys. Blood oxygen level-dependent MR evaluates intrarenal oxygen bioavailability, generating the parameter of R2* (reflecting the concentration of deoxyhemoglobin). A decrease in R2* could happen during acute rejection. MR nephro-urography/renography demonstrates structural data depicting urinary tract obstructions and functional data regarding the glomerular filtration and blood flow. MR angiography details the transplant vasculature and is particularly suitable for detecting vascular complications, with good correlation with digital subtraction angiography. Other functional MRI technologies, such as arterial spin labeling and MR spectroscopy, are showing additional promise. This review highlights MRI as a comprehensive modality to diagnose a variety of etiologies of graft dysfunction, including prerenal (e.g., renal vasculature), renal (intrinsic causes) and postrenal (e.g., obstruction of the collecting system) etiologies.

  10. Functional assessment of transplanted kidneys with magnetic resonance imaging

    Institute of Scientific and Technical Information of China (English)

    Yu-Ting; Wang; Ying-Chun; Li; Long-Lin; Yin; Hong; Pu; Jia-Yuan; Chen

    2015-01-01

    Kidney transplantation has emerged as the treatment of choice for many patients with end-stage renal disease, which is a significant cause of morbidity and mortality. Given the shortage of clinically available donor kidneys and the significant incidence of allograft dysfunction, a noninvasive and accurate assessment of the allograft renal function is critical for postoperative management. Prompt diagnosis of graft dysfunction facilitates clinical intervention of kidneys with salvageable function. New advances in magnetic resonance imaging(MRI) technology have enabled the calculation of various renal parameters that were previously not feasible to measure noninvasively. Diffusion-weighted imaging provides information on renal diffusion and perfusion simultaneously, with quantification by the apparent diffusion coefficient, the decrease of which reflects renal function impairment. Diffusion-tensor imaging accounts for the directionality of molecular motion and measures fractional anisotropy of the kidneys. Blood oxygen level-dependent MR evaluates intrarenal oxygen bioavailability, generating the parameter of R2*(reflecting the concentration of deoxyhemoglobin). A decrease in R2* could happen during acute rejection. MR nephro-urography/renography demonstrates structural data depicting urinary tract obstructions and functional data regarding the glomerular filtration and blood flow. MR angiography details the transplant vasculature and is particularly suitable for detecting vascular complications, with good correlation with digital subtraction angiography. Other functional MRI technologies, such as arterial spin labeling and MR spectroscopy, are showing additional promise. This review highlights MRI as a comprehensive modality to diagnose a variety of etiologies of graft dysfunction, including prerenal(e.g., renal vasculature), renal(intrinsic causes) and postrenal(e.g., obstruction of the collecting system) etiologies.

  11. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  12. Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations

    Directory of Open Access Journals (Sweden)

    van Rossum Albert C

    2009-03-01

    Full Text Available Abstract These reporting guidelines are recommended by the Society for Cardiovascular Magnetic Resonance (SCMR to provide a framework for healthcare delivery systems to disseminate cardiac and vascular imaging findings related to the performance of cardiovascular magnetic resonance (CMR examinations.

  13. Magnetic resonance imaging of iliotibial band syndrome.

    Science.gov (United States)

    Ekman, E F; Pope, T; Martin, D F; Curl, W W

    1994-01-01

    Seven cases of iliotibial band syndrome and the pathoanatomic findings of each, as demonstrated by magnetic resonance imaging, are presented. These findings were compared with magnetic resonance imaging scans of 10 age- and sex-matched control knees without evidence of lateral knee pain. Magnetic resonance imaging signal consistent with fluid was seen deep to the iliotibial band in the region of the lateral femoral epicondyle in five of the seven cases. Additionally, when compared with the control group, patients with iliotibial band syndrome demonstrated a significantly thicker iliotibial band over the lateral femoral epicondyle (P iliotibial band in the disease group was 5.49 +/- 2.12 mm, as opposed to 2.52 +/- 1.56 mm in the control group. Cadaveric dissections were performed on 10 normal knees to further elucidate the exact nature of the area under the iliotibial band. A potential space, i.e., a bursa, was found between the iliotibial band and the knee capsule. This series suggests that magnetic resonance imaging demonstrates objective evidence of iliotibial band syndrome and can be helpful when a definitive diagnosis is essential. Furthermore, correlated with anatomic dissection, magnetic resonance imaging identifies this as a problem within a bursa beneath the iliotibial band and not a problem within the knee joint.

  14. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  15. Magnetic resonance of magnetic fluid and magnetoliposome preparations

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Paulo C. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil)]. E-mail: pcmor@unb.br; Santos, Judes G. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Skeff Neto, K. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Pelegrini, Fernando [Universidade Federal de Goias, Instituto de Fisica, 74001-970 Goiania-GO (Brazil); Cuyper, Marcel de [Katholieke Universiteit Leuven, Campus Kortrijk, Interdisciplinary Research Centre, B-8500 Kortrijk (Belgium)

    2005-05-15

    In this study, magnetic resonance was used to investigate lauric acid-coated magnetite-based magnetic fluid particles and particles which are surrounded by a double layer of phospholipid molecules (magnetoliposomes). The data reveal the presence of monomers and dimers in both samples. Whereas evidence for a thermally induced disruption of dimers is found in the magnetic fluid, apparently, the bilayer phospholipid envelop prevents the dissociation in the magnetoliposome samples.

  16. Tutte polynomial in functional magnetic resonance imaging

    Science.gov (United States)

    García-Castillón, Marlly V.

    2015-09-01

    Methods of graph theory are applied to the processing of functional magnetic resonance images. Specifically the Tutte polynomial is used to analyze such kind of images. Functional Magnetic Resonance Imaging provide us connectivity networks in the brain which are represented by graphs and the Tutte polynomial will be applied. The problem of computing the Tutte polynomial for a given graph is #P-hard even for planar graphs. For a practical application the maple packages "GraphTheory" and "SpecialGraphs" will be used. We will consider certain diagram which is depicting functional connectivity, specifically between frontal and posterior areas, in autism during an inferential text comprehension task. The Tutte polynomial for the resulting neural networks will be computed and some numerical invariants for such network will be obtained. Our results show that the Tutte polynomial is a powerful tool to analyze and characterize the networks obtained from functional magnetic resonance imaging.

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... with claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... with claustrophobia. Newer open MRI units provide very high quality images for many types of exams; however, ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... food, or the environment, or if you have asthma. The contrast material most commonly used for an ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic field is produced by passing an electric current through wire coils in most MRI units. Other ... that are detected by the coils. The electric current does not come in contact with the patient. ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field is produced by passing an electric current through wire coils in most MRI units. Other ... that are detected by the coils. The electric current does not come in contact with the patient. ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or potentially pose a risk, depending on their nature and the strength of the MRI magnet. Many ... of the body being studied. If a contrast material will be used in the MRI exam, a ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or potentially pose a risk, depending on their nature and the strength of the MRI magnet. Many ... is positioned around the head. If a contrast material will be used in the MRI exam, a ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... evaluate infections assess blood flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is ... routine and have him/her take food and medications as usual. Some MRI examinations may require your ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  8. Magnetic resonance signal moment determination using the Earth's magnetic field

    Science.gov (United States)

    Fridjonsson, E. O.; Creber, S. A.; Vrouwenvelder, J. S.; Johns, M. L.

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  9. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  10. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  11. Magnetic Microparticle Aggregation For Viscosity Determination By Magnetic Resonance

    Science.gov (United States)

    Hong, Rui; Cima, Michael J.; Weissleder, Ralph; Josephson, Lee

    2009-01-01

    Micron-sized magnetic particles were induced to aggregate when placed in homogeneous magnetic fields, like those of magnetic resonance (MR) imagers and relaxometers, and then spontaneously returned to their dispersed state when removed from the field. Associated with the aggregation and dispersion of the magnetic particles were time dependent increases and decreases in the spin-spin relaxation time (T2) of the water. Magnetic nanoparticles, with far smaller magnetic moments per particle, did not undergo magnetically induced aggregation, and exhibited time independent values of T2. The rate of T2 change associated with magnetic micro-particle aggregation was used to determine the viscosity of liquid samples, providing a method that can be of particular advantage for determining the viscosity of small volumes of potentially biohazardous samples of blood or blood plasma. PMID:18306403

  12. 糖尿病肾病的磁共振扩散成像及灌注成像研究%Study on magnetic resonance diffusion weighted imaging and magnetic resonance perfusion imaging of the dia-gnoses of diabetic renal injury

    Institute of Scientific and Technical Information of China (English)

    秦卫和; 陈学文; 陈艳姣; 付飞先; 黎晶; 卜雨华

    2014-01-01

    Objective To investigate the renal function of diabetic nephropathy patients by using magnetic resonance(MR) diffusion weighted imaging(DWI) and MR perfusion imaging(PWI), and to evaluate the role of DWI and PWI in diagnosis of early renal dysfunction in patients with diabetic nephropathy. Methods Fifty diabetic nephropathy and 20 check-up subjects (healthy control group) were checked using DWI. Seventeen diabetic nephropathy patients and 15 check-up subjects were checked using PWI. Single-shot echo planar image DWI,dynamic enhanced MRI scanning and routine MR sequence scan were used to measure bilateral kidneys in these patients or healthy subjects. Results The ADC values of the phaseⅠof the diabetic nephropathy group and phase Ⅱ of the diabetic nephropathy group had no significant difference comparing with healthy control group , the ADC values of phaseⅢ-Ⅴ of the diabetic nephropathy groups were significantly lower than those in healthy control group and the phaseⅠ-Ⅱ of thediabetic nephropathy groups. Mean peak intensity value and the P/T time to peak ratio at the cortex and medulla of phaseⅠ-Ⅱ of the diabetic nephropathy groups were no significant difference comparing with healthy control group (all P>0.05), but phase Ⅲ-Ⅴof the diabetic nephropathy groups were significantly lower than those in healthy control group and the phaseⅠ-Ⅱ of the diabetic nephropathy groups. Conclusion DWI and PWI may be more useful in identifying early renal dysfunction in patients with diabetic nephropathy.%目的探讨磁共振扩散加权成像(DWI)及灌注成像(PWI)在观察糖尿病肾病的诊断价值。方法行磁共振DWI检查的50例糖尿病肾病患者,行磁共振肾脏PWI检查的17例糖尿病肾病患者资料,行磁共振DWI检查的健康对照者20名,行磁共振PWI的健康对照者15名,所有检查者均行磁共振常规平扫,然后行磁共振DWI检查及PWI检查。结果Ⅰ~Ⅱ期的糖尿病肾病患者的肾

  13. Near-zero-field nuclear magnetic resonance

    OpenAIRE

    Ledbetter, Micah; Theis, Thomas; Blanchard, John; Ring, Hattie; Ganssle, Paul; Appelt, Stephan; Bluemich, Bernhard; Pines, Alex; Budker, Dmitry

    2011-01-01

    We investigate nuclear magnetic resonance (NMR) in near-zero-field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J-coupling). This is in stark contrast to the high field case, where heteronuclear J-couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectr...

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Therapy November 8 is the International Day of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  15. Functional Magnetic Resonance Imaging in Consumer Research

    DEFF Research Database (Denmark)

    Reimann, Martin; Schilke, Oliver; Weber, Bernd

    2011-01-01

    Although the field of psychology is undergoing an immense shift toward the use of functional magnetic resonance imaging (fMRI), the application of this methodology to consumer research is relatively new. To assist consumer researchers in understanding fMRI, this paper elaborates on the findings...

  16. Modelling Strategies for Functional Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Madsen, Kristoffer Hougaard

    2009-01-01

    This thesis collects research done on several models for the analysis of functional magnetic resonance neuroimaging (fMRI) data. Several extensions for unsupervised factor analysis type decompositions including explicit delay modelling as well as handling of spatial and temporal smoothness...

  17. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  18. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD proje...

  19. Pituitary magnetic resonance imaging in Cushing's disease.

    Science.gov (United States)

    Vitale, Giovanni; Tortora, Fabio; Baldelli, Roberto; Cocchiara, Francesco; Paragliola, Rosa Maria; Sbardella, Emilia; Simeoli, Chiara; Caranci, Ferdinando; Pivonello, Rosario; Colao, Annamaria

    2017-03-01

    Adrenocorticotropin-secreting pituitary tumor represents about 10 % of pituitary adenomas and at the time of diagnosis most of them are microadenomas. Transsphenoidal surgery is the first-line treatment of Cushing's disease and accurate localization of the tumor within the gland is essential for selectively removing the lesion and preserving normal pituitary function. Magnetic resonance imaging is the best imaging modality for the detection of pituitary tumors, but adrenocorticotropin-secreting pituitary microadenomas are not correctly identified in 30-50 % of cases, because of their size, location, and enhancing characteristics. Several recent studies were performed with the purpose of better localizing the adrenocorticotropin-secreting microadenomas through the use in magnetic resonance imaging of specific sequences, reduced contrast medium dose and high-field technology. Therefore, an improved imaging technique for pituitary disease is mandatory in the suspect of Cushing's disease. The aims of this paper are to present an overview of pituitary magnetic resonance imaging in the diagnosis of Cushing's disease and to provide a magnetic resonance imaging protocol to be followed in case of suspicion adrenocorticotropin-secreting pituitary adenoma.

  20. Magnetic resonance imaging in acute tendon ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H.; Lupetin, A.R.; Dash, N.; Riemer, B.L.

    1986-11-01

    The diagnosis of acute tendon ruptures of the extensor mechanism of the knee or the Achilles tendon of the ankle may usually be made by clinical means. Massive soft tissue swelling accompanying these injuries often obscures the findings, however. Magnetic resonance imaging (MRI) can rapidly demonstrate these tendon ruptures. Examples of the use of MRI for quadriceps tendon, and Achilles tendon rupture are presented.

  1. Cardiovascular magnetic resonance: physics and terminology.

    Science.gov (United States)

    Rodgers, Christopher T; Robson, Matthew D

    2011-01-01

    Cardiovascular magnetic resonance (CMR) is the branch of magnetic resonance imaging (MRI) whose acquisition methods are adapted to surmount the particular challenges caused by motion of the heart and blood in vivo. Magnetic resonance imaging is supremely flexible; it can produce images showing the spatial distribution of diverse tissue characteristics, for example, proton density, T(1), T(2), T(2)(⁎), fat concentration, flow rate, and diffusion parameters. The image contrast may usefully be modified by intravenous infusion of contrast agents. Magnetic resonance imaging permits 2-dimensional or 3-dimensional acquisitions with arbitrary slice orientation. Unfortunately, MRI's flexibility is matched by a remarkable complexity not only in its fundamental principles but also in the optimization of applications in the clinic. This article attempts to demystify the basic principles of CMR and provides a primer on the terminology used in CMR. Complete confidence in the principles of CMR is not essential to use the technology. Nevertheless, knowledge of the principal terminology of MRI is a valuable first step when seeking to understand and apply modern methods in a clinical or research setting. Thus, the article closes with a glossary of terminology and references to high-quality educational resources. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  3. Was magnetic resonance imaging scan contraindicated?

    Science.gov (United States)

    Rafiq, Muhammad Khizar

    2010-01-01

    An intravenous drug abuser with a retained needle posed a management problem at a neurosurgical unit, having declined magnetic resonance imaging (MRI) on safety grounds. However, later, having been assessed by the senior radiologist, she went though the MRI scan safely.

  4. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    Science.gov (United States)

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  5. Biliary ascariasis on magnetic resonance cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Mohammad A Hashmi

    2009-01-01

    Full Text Available A 17-year-old girl presented with features of biliary obstruction. Magnetic resonance cholangi-pancreatography revealed typical linear signals in common bile duct, which appears like Ascaris lumbricoides. The diagnosis was confirmed by endoscopic removal of the worm.

  6. Sports health magnetic resonance imaging challenge.

    Science.gov (United States)

    Howell, Gary A; Stadnick, Michael E; Awh, Mark H

    2010-11-01

    Injuries to the Lisfranc ligament complex are often suspected, particularly in the setting of midfoot pain without radiographic abnormality. Knowledge of the anatomy and magnetic resonance imaging findings of injuries to this region is helpful for the diagnosing and treating physicians.

  7. Magnetic Resonance Imaging in Biomedical Engineering

    Science.gov (United States)

    Kaśpar, Jan; Hána, Karel; Smrčka, Pavel; Brada, Jiří; Beneš, Jiří; Šunka, Pavel

    2007-11-01

    The basic principles of magnetic resonance imaging covering physical principles and basic imaging techniques will be presented as a strong tool in biomedical engineering. Several applications of MRI in biomedical research practiced at the MRI laboratory of the FBMI CTU including other laboratory instruments and activities are introduced.

  8. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    2001-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing rad

  9. Magnetic Resonance Angiography: Principles and Applications.

    Science.gov (United States)

    Dyke, Lara M

    2013-12-01

    Magnetic Resonance Angiography: Principles and Applications. Carr J. C., Carroll T. J., Springer-Verlag, Heidelberg/New York, 2012. 412 pp. Price $179.00. ISBN 978-1-4419-1685-3 (hardcover). © 2013 American Association of Physicists in Medicine.

  10. Magnetic resonance imaging (MRI) in syringomyelia

    NARCIS (Netherlands)

    H.L.J. Tanghe (Hervé)

    1995-01-01

    textabstractBased on an own material of 19 patients with syringomyelia and on the related literature a survey is given on the diagnosis, differential diagnosis, postoperative evaluation and the dynamics of CSF and cyst fluids, using magnetic resonance imaging (MRI). The following conclusions can be

  11. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  12. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD proje...

  13. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  14. NON-CONTRAST MAGNETIC RESONANCE UROGRAPHY

    Directory of Open Access Journals (Sweden)

    Arpita C

    2016-07-01

    Full Text Available BACKGROUND AND PURPOSE Magnetic Resonance (MR urography with its optimal contrast resolution and lack of ionizing radiation provides a comprehensive examination of the entire urinary tract noninvasively. MR urography is clinically useful in the evaluation of suspected urinary tract obstruction, haematuria, congenital anomalies, and surgically altered anatomy. It is particularly useful in cases of where there is contraindication of ionizing radiation and in paediatric and pregnant patients. The common MR urographic techniques are: Static-fluid MR urography and excretory MR urography. Static-fluid MR urography uses of heavily T2-weighted sequences to image the urinary tract as a static collection of fluid, can be repeated sequentially (Cine MR urography to better demonstrate the ureters in their entirety and to confirm the presence of fixed stenoses. Excretory MR urography is performed during the excretory phase of enhancement after the intravenous administration of gadolinium-based contrast material; thus, the patient must have sufficient renal function to allow the excretion. Static-fluid and excretory MR urography can be combined with conventional MR imaging for comprehensive evaluation of the urinary tract. The limitations are limited availability, high cost, relatively long examination time, low spatial resolution compared to IVU (Intravenous Urogram and CT Urography; sensitivity to motion (breathing and ureteral peristalsis inherent contraindications like patients with pacemakers, claustrophobia, and relative insensitivity for calcification and ureteric calculi. In this article, an attempt has been made to demonstrate the potential of static-fluid MRU to demonstrate a spectrum of urologic pathology involving the kidneys, ureters, and bladder while discussing the limitations. METHODS Thirty patients with urinary tract abnormalities were evaluated with MR urography performed between May 2014 to April 2016 using routine MR sequences and

  15. Interaction of magnetic resonators studied by the magnetic field enhancement

    Science.gov (United States)

    Hou, Yumin

    2013-12-01

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters-shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  16. Interaction of magnetic resonators studied by the magnetic field enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yumin, E-mail: ymhou@pku.edu.cn [State Key Laboratory for Mesoscopic Physics, School of Physics, Peking University, Beijing 100871 (China)

    2013-12-15

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  17. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  18. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  19. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  20. The working principle of magnetic resonance therapy

    CERN Document Server

    Brizhik, Larissa; Fermi, Enrico

    2015-01-01

    In this paper we describe briefly the basic aspects of magnetic resonance therapy, registered as TMR therapy. Clinical studies have shown that application of this therapy significantly accelerates wound healing and, in particular, healing of the diabetic foot disease. To understand the working principle of this therapy, we analyze relevant to it biological effects produced by magnetic fields. Based on these data, we show that there is a hierarchy of the possible physical mechanisms, which can produce such effects. The mutual interplay between the mechanisms can lead to a synergetic outcome delayed in time, which can affect the physiological state of the organism. In particular, we show that soliton mediated charge transport during the redox processes in living organisms is sensitive to magnetic fields, so that such fields can facilitate redox processes in particular, and can stimulate the healing effect of the organism in general. This and other non-thermal resonant mechanisms of the biological effects of mag...

  1. Magnetic resonance imaging in inflammatory rheumatoid diseases.

    Science.gov (United States)

    Sudoł-Szopińska, Iwona; Mróz, Joanna; Ostrowska, Monika; Kwiatkowska, Brygida

    2016-01-01

    Magnetic resonance (MR) is used more and more frequently to diagnose changes in the musculoskeletal system in the course of rheumatic diseases, at their initial assessment, for treatment monitoring and for identification of complications. The article presents the history of magnetic resonance imaging, the basic principles underlying its operation as well as types of magnets, coils and MRI protocols used in the diagnostic process of rheumatic diseases. It enumerates advantages and disadvantages of individual MRI scanners. The principles of MRI coil operation are explained, and the sequences used for MR image analysis are described, particularly in terms of their application in rheumatology, including T1-, T2-, PD-weighted, STIR/TIRM and contrast-enhanced T1-weighted images. Furthermore, views on the need to use contrast agents to optimise diagnosis, particularly in synovitis-like changes, are presented. Finally, methods for the assessment of MR images are listed, including the semi-quantitative method by RAMRIS and quantitative dynamic examination.

  2. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  3. Minimizing Risk of Nephrogenic systemic fibrosis in Cardiovascular Magnetic Resonance

    Directory of Open Access Journals (Sweden)

    Reiter Theresa

    2012-05-01

    Full Text Available Abstract Nephrogenic Systemic Fibrosis is a rare condition appearing only in patients with severe renal impairment or failure and presents with dermal lesions and involvement of internal organs. Although many cases are mild, an estimated 5 % have a progressive debilitating course. To date, there is no known effective treatment thus stressing the necessity of ample prevention measures. An association with the use of Gadolinium based contrast agents (GBCA makes Nephrogenic Systemic Fibrosis a potential side effect of contrast enhanced magnetic resonance imaging and offers the opportunity for prevention by limiting use of gadolinium based contrast agents in renal failure patients. In itself toxic, Gadolinium is embedded into chelates that allow its safe use as a contrast agent. One NSF theory is that Gadolinium chelates distribute into the extracellular fluid compartment and set Gadolinium ions free, depending on multiple factors among which the duration of chelates exposure is directly related to the renal function. Major medical societies both in Europe and in North America have developed guidelines for the usage of GBCA. Since the establishment of these guidelines and the increased general awareness of this condition, the occurrence of NSF has been nearly eliminated. Giving an overview over the current knowledge of NSF pathobiochemistry, pathogenesis and treatment options this review focuses on the guidelines of the European Medicines Agency, the European Society of Urogenital Radiology, the FDA and the American College of Radiology from 2008 up to 2011 and the transfer of this knowledge into every day practice.

  4. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  5. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    2013-01-01

    Advances in Magnetic and Optical Resonance contains three articles which review quite fundamentally different aspects of coherent spectroscopy. An enormous variety of effects can be observed when optical and spin resonances are coupled, usually by a combination of radio frequency and laser irradiation. The first article reviews these effects and pays particular attention to developing a theoretical framework which is as similar as possible for the optical and spin cases. Subsequent articles examine deuterium relaxation in molecular solids, and the spatiotemporal growth of multiple spin coheren

  6. Magnetic resonance imaging and its applicability in veterinary cardiology

    OpenAIRE

    Ferreira, José Manuel de Seiça

    2016-01-01

    Magnetic Resonance Imaging (MRI) is a technique whereby images are created by the manipulation of hydrogen atoms in magnetic fields; it is based on the principle of nuclear magnetic resonance (MR), which is non-invasive and non-ionising (Constantine, Shan, Flamm, & Sivananthan, 2004). Cardiac Magnetic Resonance Imaging (CMRI) uses the same principle: application of magnetic-field gradients that are adjusted to highlight desired tissue characteristics, producing a variety of sequences that all...

  7. Resonantly detecting axion-mediated forces with nuclear magnetic resonance.

    Science.gov (United States)

    Arvanitaki, Asimina; Geraci, Andrew A

    2014-10-17

    We describe a method based on precision magnetometry that can extend the search for axion-mediated spin-dependent forces by several orders of magnitude. By combining techniques used in nuclear magnetic resonance and short-distance tests of gravity, our approach can substantially improve upon current experimental limits set by astrophysics, and probe deep into the theoretically interesting regime for the Peccei-Quinn (PQ) axion. Our method is sensitive to PQ axion decay constants between 10(9) and 10(12) GeV or axion masses between 10(-6) and 10(-3) eV, independent of the cosmic axion abundance.

  8. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  9. High speed functional magnetic resonance imaging

    CERN Document Server

    Gibson, A M

    2002-01-01

    The work in this thesis has been undertaken by the except where indicated by reference, within the Magnetic Resonance Centre at the University of Nottingham during the period from October 1998 to October 2001. This thesis documents the implementation and application of a novel high-speed imaging technique, the multi-slice, echo shifted, echo planar imaging technique. This was implemented on the Nottingham 3 T imaging system, for functional magnetic resonance imaging. The technique uses echo shifting over the slices in a multi-slice echo planar imaging acquisition scheme, making the echo time longer than the repetition time per slice. This allows for rapid volumar sampling of the blood oxygen level dependent effect in the human brain. The new high-speed technique was used to investigate the variability of measuring the timing differences between haemodynamic responses, at the same cortical location, to simple cued motor tasks. The technique was also used in an investigation into motor cortex functional connect...

  10. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  11. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.;

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper review...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8......Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  12. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  13. Introduction to Magnetic Resonance Imaging Techniques

    OpenAIRE

    2009-01-01

    It is quite possible to acquire images with an MR scanner without understanding the principles behind it, but choosing the best parameters and methods, and interpreting images and artifacts, requires understanding. This text serves as an introduction to magnetic resonance imaging techniques. It is aimed at beginners in possession of only a minimal level of technical expertise, yet it introduces aspects of MR that are typically considered technically challenging. The notes were written in conn...

  14. Magnetic resonance in diagnosis of ureterocele

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Humberto do; Hachul, Mauricio; Macedo Junior, Antonio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Div. de Urologia]. E-mail: humbertojr1@aol.com

    2003-05-15

    Ultrasonography is the main non-invasive technique for screening of ureterocele, but presents some difficulties for its diagnosis. Other supplementary diagnostic methods have the disadvantage of being invasive or using ionizing radiation. Magnetic resonance (MR) has a high sensitivity for diagnosing urinary tract malformations in adults and children. We report one case of ureterocele in a 1-year old child with the purpose of presenting its diagnosis through MR. (author)

  15. "PALPATION BY IMAGING": MAGNETIC RESONANCE ELASTOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Lei Xu; Pei-yi Gao

    2006-01-01

    Elasticity is an important physical property of human tissues.There is a tremendous difference in elasticity between normal and pathological tissues.Noninvasive evaluation of the elasticity of human tissues would be valuable for clinical practice.Magnetic resonance elastography(MRE)is a recently developed noninvasive imaging technique that can directly visualize and quantitatively measure tissue elasticity.This article reviewed the MRE technique and its current status.

  16. Perfusion magnetic resonance imaging of the liver

    Institute of Scientific and Technical Information of China (English)

    Choon; Hua; Thng; Tong; San; Koh; David; J; Collins; Dow; Mu; Koh

    2010-01-01

    Perfusion magnetic resonance imaging (MRI) studies quantify the microcirculatory status of liver parenchyma and liver lesions, and can be used for the detection of liver metastases, assessing the effectiveness of antiangiogenic therapy, evaluating tumor viability after anticancer therapy or ablation, and diagnosis of liver cirrhosis and its severity. In this review, we discuss the basic concepts of perfusion MRI using tracer kinetic modeling, the common kinetic models applied for analyses, the MR scanning t...

  17. Magnetic resonance acoustic radiation force imaging.

    Science.gov (United States)

    McDannold, Nathan; Maier, Stephan E

    2008-08-01

    Acoustic radiation force impulse imaging is an elastography method developed for ultrasound imaging that maps displacements produced by focused ultrasound pulses systematically applied to different locations. The resulting images are "stiffness weighted" and yield information about local mechanical tissue properties. Here, the feasibility of magnetic resonance acoustic radiation force imaging (MR-ARFI) was tested. Quasistatic MR elastography was used to measure focal displacements using a one-dimensional MRI pulse sequence. A 1.63 or 1.5 MHz transducer supplied ultrasound pulses which were triggered by the magnetic resonance imaging hardware to occur before a displacement-encoding gradient. Displacements in and around the focus were mapped in a tissue-mimicking phantom and in an ex vivo bovine kidney. They were readily observed and increased linearly with acoustic power in the phantom (R2=0.99). At higher acoustic power levels, the displacement substantially increased and was associated with irreversible changes in the phantom. At these levels, transverse displacement components could also be detected. Displacements in the kidney were also observed and increased after thermal ablation. While the measurements need validation, the authors have demonstrated the feasibility of detecting small displacements induced by low-power ultrasound pulses using an efficient magnetic resonance imaging pulse sequence that is compatible with tracking of a dynamically steered ultrasound focal spot, and that the displacement increases with acoustic power. MR-ARFI has potential for elastography or to guide ultrasound therapies that use low-power pulsed ultrasound exposures, such as drug delivery.

  18. Electro-Mechanical Resonant Magnetic Field Sensor

    CERN Document Server

    Temnykh, A B; Temnykh, Alexander B.; Lovelace, Richard V. E.

    2002-01-01

    We describe a new type of magnetic field sensor which is termed an Electro-Mechanical Resonant Sensor (EMRS). The key part of this sensor is a small conductive elastic element with low damping rate and therefore a high Q fundamental mode of frequency $f_1$. An AC current is driven through the elastic element which, in the presence of a magnetic field, causes an AC force on the element. When the frequency of the AC current matches the resonant frequency of the element, maximum vibration of the element occurs and this can be measured precisely by optical means. We have built and tested a model sensor of this type using for the elastic element a length of copper wire of diameter 0.030 mm formed into a loop shape. The wire motion was measured using a light emitting diode photo-transistor assembly. This sensor demonstrated a sensitivity better than 0.001G for an applied magnetic field of $ \\sim 1$G and a good selectivity for the magnetic field direction. The sensitivity can be easily improved by a factor of $\\sim ...

  19. Recent advances in magnetic resonance imaging for stroke diagnosis

    Directory of Open Access Journals (Sweden)

    Radhika Rastogi

    2015-01-01

    Full Text Available In stroke, diagnosis and identification of the infarct core and the penumbra is integral to therapeutic determination. With advances in magnetic resonance imaging (MRI technology, stroke visualization has been radically altered. MRI allows for better visualization of factors such as cerebral microbleeds (CMBs, lesion and penumbra size and location, and thrombus identification; these factors help determine which treatments, ranging from tissue plasminogen activator (tPA, anti-platelet therapy, or even surgery, are appropriate. Current stroke diagnosis standards use several MRI modalities in conjunction, with T2- or T2FNx01- weighted MRI to rule out intracerebral hemorrhage (ICH, magnetic resonance angiography (MRA for thrombus identification, and the diffusion-weighted imaging (DWI and perfusion-weighted imaging (PWI mismatch for penumbral identification and therapeutic determination. However, to better clarify the neurological environment, susceptibility-weighted imaging (SWI for assessing oxygen saturation and the presence of CMBs as well as additional modalities, such as amide proton transfer (APT imaging for pH mapping, have emerged to offer more insight into anatomical and biological conditions during stroke. Further research has unveiled potential for alternative contrasts to gadolinium for PWI as well, as the contrast has contraindications for patients with renal disease. Superparamagnetic iron oxide nanoparticles (SPIONs as an exogenous contrast and arterial spin labeling (ASL as an endogenous contrast offer innovative alternatives. Thus, emerging MRI modalities are enhancing the diagnostic capabilities of MRI in stroke and provide more guidance for patient outcome by offering increased accessibility, accuracy, and information.

  20. Compact low field magnetic resonance imaging magnet: Design and optimization

    Science.gov (United States)

    Sciandrone, M.; Placidi, G.; Testa, L.; Sotgiu, A.

    2000-03-01

    Magnetic resonance imaging (MRI) is performed with a very large instrument that allows the patient to be inserted into a region of uniform magnetic field. The field is generated either by an electromagnet (resistive or superconductive) or by a permanent magnet. Electromagnets are designed as air cored solenoids of cylindrical symmetry, with an inner bore of 80-100 cm in diameter. In clinical analysis of peripheral regions of the body (legs, arms, foot, knee, etc.) it would be better to adopt much less expensive magnets leaving the most expensive instruments to applications that require the insertion of the patient in the magnet (head, thorax, abdomen, etc.). These "dedicated" apparati could be smaller and based on resistive magnets that are manufactured and operated at very low cost, particularly if they utilize an iron yoke to reduce power requirements. In order to obtain good field uniformity without the use of a set of shimming coils, we propose both particular construction of a dedicated magnet, using four independently controlled pairs of coils, and an optimization-based strategy for computing, a posteriori, the optimal current values. The optimization phase could be viewed as a low-cost shimming procedure for obtaining the desired magnetic field configuration. Some experimental measurements, confirming the effectiveness of the proposed approach (construction and optimization), have also been reported. In particular, it has been shown that the adoption of the proposed optimization based strategy has allowed the achievement of good uniformity of the magnetic field in about one fourth of the magnet length and about one half of its bore. On the basis of the good experimental results, the dedicated magnet can be used for MRI of peripheral regions of the body and for animal experimentation at very low cost.

  1. Portal biliopathy, magnetic resonance imaging and magnetic resonance cholangiopancreatography findings: a case series

    Science.gov (United States)

    Baskan, Ozdil; Erol, Cengiz; Sahingoz, Yusuf

    2016-01-01

    Portal biliopathy (PB) is a rare disorder, characterized by biliary ductal and gallbladder wall abnormalities seen in patients with portal hypertension. It most commonly occurs due to idiopathic extrahepatic portal vein obstruction (EHPVO). The abnormalities consist mainly of bile duct compression, stenoses, fibrotic strictures and dilation of both extrahepatic and intrahepatic bile ducts, as well as gallbladder varices. PB may mimic cholangiocarcinoma, sclerosing cholangitis, or choledocholithiasis. Misdiagnosis can be avoided using appropriate imaging modalities to prevent complications. We present the magnetic resonance imaging (MRI) and magnetic resonance cholangiography (MRCP) features of three patients with PB. PMID:25216728

  2. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  3. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  4. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ... HUMAN SERVICES Food and Drug Administration Magnetic Resonance Imaging Safety; Public Workshop AGENCY... the safe use of magnetic resonance imaging (MRI) and approaches to mitigate risks. The overall goal is...: The Food and Drug Administration (FDA) is announcing a public workshop entitled: ``Magnetic...

  5. Molecular structure and motion in zero field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed.

  6. Achilles Impingement Tendinopathy on Magnetic Resonance Imaging.

    Science.gov (United States)

    Bullock, Mark J; Mourelatos, Jan; Mar, Alice

    2017-02-28

    Haglund's syndrome is impingement of the retrocalcaneal bursa and Achilles tendon caused by a prominence of the posterosuperior calcaneus. Radiographic measurements are not sensitive or specific for diagnosing Haglund's deformity. Localization of a bone deformity and tendinopathy in the same sagittal section of a magnetic resonance imaging scan can assist with the diagnosis in equivocal cases. The aim of the present cross-sectional study was to determine the prevalence of Haglund's syndrome in patients presenting with Achilles tendinopathy and note any associated findings to determine the criteria for a diagnosis of Haglund's syndrome. We reviewed 40 magnetic resonance imaging scans with Achilles tendinopathy and 19 magnetic resonance imaging scans with Achilles high-grade tears and/or ruptures. Achilles tendinopathy was often in close proximity to the superior aspect of the calcaneal tuberosity, consistent with impingement (67.5%). Patients with Achilles impingement tendinopathy were more often female (p < .04) and were significantly heavier than patients presenting with noninsertional Achilles tendinopathy (p = .014) or Achilles tendon rupture (p = .010). Impingement tendinopathy occurred medially (8 of 20) and centrally (10 of 20) more often than laterally (2 of 20) and was associated with a posterior prominence or hyperconvexity with a loss of calcaneal recess more often than a superior projection (22 of 27 versus 8 of 27; p < .001). Haglund's deformity should be reserved for defining a posterior prominence or hyperconvexity with loss of calcaneal recess because this corresponds with impingement. Achilles impingement tendinopathy might be more appropriate terminology for Haglund's syndrome, because the bone deformity is often subtle. Of the 27 images with Achilles impingement tendinopathy, 10 (37.0%) extended to a location prone to Achilles tendon rupture. Given these findings, insertional and noninsertional Achilles tendinopathy are not mutually

  7. Magnetic resonance in hearing loss and vertigo

    Directory of Open Access Journals (Sweden)

    Manuel Ángel MARTÍN-PÉREZ

    2017-03-01

    Full Text Available Introduction and objective: Hearing loss and vertiginous syndrome represent an important part of the otorhinolaryngology clinic. The role of the radiologist plays in their workup become fundamental. Studies using magnetic resonance imaging (MRI are essential to guide or give the diagnosis in these cases. Method: After performing a retrospective analysis of 456 MRI studies of patients with these symptoms, we conducted a review of the main pathologies recorded that can cause these symptoms. Results: We classify into vascular disorders and other variants, tumor pathology, malformations and inflammatory pathology; We also describe the most relevant findings on MRI and illustrated with examples of our center.

  8. Magnetic Resonance Imaging of Thyroid and Parathyroid

    Directory of Open Access Journals (Sweden)

    Miguel Gonzalo-Domínguez

    2016-11-01

    Full Text Available Introduction: The assessment of the thyroid and parathyroid pathology is usually achieved with ultrasounds. There are several systems of classification that are internationally accepted in neoplastic disease, such as TIRADS system, and there are well-defined patterns for ultrasound imaging in inflammatory disease. Material and methods: However, there are specific needs that require magnetic resonance imaging. We review the main indications of MRI in the evaluation of thyroid and parathyroid in 64 patients and determine which protocols are more appropriate and which sequences are better for a proper characterization. Results: Then we review the semiology obtained by this technique, making correlation with disease processes affecting these cervical structures.

  9. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  10. Cardiovascular magnetic resonance in systemic hypertension

    Directory of Open Access Journals (Sweden)

    Maceira Alicia M

    2012-06-01

    Full Text Available Abstract Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension.

  11. Cardiovascular magnetic resonance in systemic hypertension

    Science.gov (United States)

    2012-01-01

    Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR) provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension. PMID:22559053

  12. Magnetic resonance images of chronic patellar tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Bodne, D.; Quinn, S.F.; Murray, W.T.; Cochran, C.; Bolton, T.; Rudd, S.; Lewis, K.; Daines, P.; Bishop, J.

    1988-01-01

    Chronic patellar tendinitis can be a frustrating diagnostic and therapeutic problem. This report evaluates seven tendons in five patients with chronic patellar tendinitis. The etiologies included 'jumper's knee' and Osgood-Schlatter disease. In all cases magnetic resonance images (MRI) showed thickening of the tendon. Some of the tendons had focal areas of thickening which helped establish the etiology. All cases had intratendinous areas of increased signal which, in four cases, proved to be chronic tendon tears. MRI is useful in evaluating chronic patellar tendinitis because it establishes the diagnosis, detects associated chronic tears, and may help determine appropriate rehabilitation. (orig.)

  13. Developments in boron magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, M.

    1995-11-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain.

  14. Magnetic resonance imaging of musculoaponeurotic fibromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Hawnaur, J.M.; Jenkins, J.P.R.; Isherwood, I. (Manchester Univ. (UK). Dept. of Diagnostic Radiology)

    1990-10-01

    Musculoaponeurotic fibromatosis can be mistaken for soft-tissue sarcoma both clinically and on X-ray computed tomography. Magnetic resonance imaging (MRI) in three patients with this condition enabled the correct diagnosis to be made prospectively in two. The appearance on MRI of a heterogeneous mass with well-defined, predominantly peripheral areas of very low signal intensity due to dense fibrous tissue and areas of medium to high signal intensity corresponding to a more cellular stroma should raise the suspicion of musculoaponeurotic fibromatosis. Cellular areas within the tumour showed moderate enhancement after gadolinium diethylene triamine pentaacetic acid administration. (orig.).

  15. Magnetic resonance imaging of rat fetuses

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Yo; Kawanishi, Hiroaki (Imamichi Institute for Animal Reproduction, Ibaraki (Japan)); Hasegawa, Kenichi; Otsu, Shinichi

    1993-06-01

    The internal structures of rat fetuses on day 18.0 of pregnancy were studied by magnetic resonance imaging in 1-mm sagittal slices. Each organ was represented as white to gray images different in tone according to the [sup 1]H proton content and the relaxation time. In solid organs, portions with high cell density were seen as white areas and those with low cell density as gray areas. In the tubular organs, the margins were imaged as white and the lumina as gray. (author).

  16. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  17. Sciatic neuropathy: findings on magnetic resonance neurography

    Science.gov (United States)

    Agnollitto, Paulo Moraes; Chu, Marcio Wen King; Simão, Marcelo Novelino; Nogueira-Barbosa, Marcello Henrique

    2017-01-01

    Injuries of the sciatic nerve are common causes of pain and limitation in the lower limbs. Due to its particular anatomy and its long course, the sciatic nerve is often involved in diseases of the pelvis or leg. In recent years, magnetic resonance neurography has become established as an important tool for the study of peripheral nerves and can be widely applied to the study of the sciatic nerve. Therefore, detailed knowledge of its anatomy and of the most prevalent diseases affecting it is essential to maximizing the accuracy of diagnostic imaging. PMID:28670031

  18. Magnetic resonance imaging of acoustic neuroma

    Energy Technology Data Exchange (ETDEWEB)

    Kashihara, Kengo; Murata, Hideaki; Ito, Haruhide; Onishi, Hiroaki; Kadoya, Masumi; Suzuki, Masayuki.

    1989-03-01

    Thirteen patients with acoustic neuroma were studied on a 1.5T superconductive magnetic resonance (MR) imager. Acoustic neuromas appeared as lower signal intensity than the surrounding brain stem on T1 weighted image (W.I.), and as higher signal intensity on T2 W.I.. Axial and coronal sections of T1 W.I. were very useful in observing the tumor in the auditory canal and in investigating the anatomical relations of the tumor and the surrounding structures. MR imaging is very excellent examination to make early diagnosis of the acoustic neuroma and preoperative anatomical evaluation.

  19. Sensorineural Hearing Loss after Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Abolfazl Mollasadeghi

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI devices produce noise, which may affect patient’s or operators’ hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus. In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient’s hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.

  20. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti......-angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...

  1. Hair product artifact in magnetic resonance imaging.

    Science.gov (United States)

    Chenji, Sneha; Wilman, Alan H; Mah, Dennell; Seres, Peter; Genge, Angela; Kalra, Sanjay

    2017-01-01

    The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic compounds. In lieu of this observation, we suggest that MRI centers include the use of metal- or mineral-based facial cosmetics or hair products in their screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Magnetic resonance imaging in rheumatology. An overview.

    Science.gov (United States)

    Nissenbaum, M A; Adamis, M K

    1994-05-01

    Magnetic resonance (MR) imaging has revolutionized the assessment of pathology involving the musculoskeletal system. The soft tissue contrast, superb resolution, multiplanar acquisition potential, and the ability to monitor physiologic processes combine the best features of other imaging modalities. The sensitivity and specificity of MR imaging for a wide range of disease processes matches or supersedes conventional radiology, nuclear medicine, and clinical examination. This article provides a brief overview of the use of MR imaging for some of the more common clinical situations confronting the rheumatologist.

  3. Cardiac magnetic resonance in clinical cardiology

    Institute of Scientific and Technical Information of China (English)

    Andreas; Kumar; Rodrigo; Bagur

    2015-01-01

    Over the last decades, cardiac magnetic resonance(CMR) has transformed from a research tool to a widely used diagnostic method in clinical cardiology. This method can now make useful, unique contributions to the work-up of patients with ischemic and non-ischemic heart disease. Advantages of CMR, compared to other imaging methods, include very high resolution imaging with a spatial resolution up to 0.5 mm × 0.5 mm in plane, a large array of different imaging sequences to provide in vivo tissue characterization, and radiationfree imaging. The present manuscript highlights the relevance of CMR in the current clinical practice and new perspectives in cardiology.

  4. Magnetic resonance imaging of the cervical region

    Energy Technology Data Exchange (ETDEWEB)

    Tjoerstad, K.; Kaass, B.; Svihus, R.

    1987-11-01

    Magnetic resonance imaging (MRI) of the cervical region was carried out on 139 patients in a ten-month period. 64 patients came from Rogaland Central Hospital and 75 from the rest of Norway. A retrospective questionnaire was filled in by the referring physicians. MRI seems to be of great value in the diagnosis of cervical vertebrogenic myelopathy, multiple sclerosis, syringomyelia, and intraspinal tumors. Besides its diagnostic superiority, at least in patients with cervical myelopathy, MRI has definite economic advantages compared to CT and myelography.

  5. [Magnetic resonance imaging of the temporomandibular joint].

    Science.gov (United States)

    Ros Mendoza, L H; Cañete Celestino, E; Velilla Marco, O

    2008-01-01

    The temporomandibular joint (TMJ) is a small joint with complex anatomy and function. Diverse pathologies with very different symptoms can affect the TMJ. While various imaging techniques such as plain-film radiography and computed tomography can be useful, magnetic resonance imaging's superior contrast resolution reveals additional structures like the articular disk, making this technique essential for accurate diagnosis and treatment planning. We analyze the MRI signs of the different pathologies that can affect the TMJ from the structural and functional points of view.

  6. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  7. Magnetic Field Gradient Calibration as an Experiment to Illustrate Magnetic Resonance Imaging

    Science.gov (United States)

    Seedhouse, Steven J.; Hoffmann, Markus M.

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopy experiment for the undergraduate physical chemistry laboratory is described that encompasses both qualitative and quantitative pedagogical goals. Qualitatively, the experiment illustrates how images are obtained in magnetic resonance imaging (MRI). Quantitatively, students experience the…

  8. Functional magnetic resonance imaging of the kidneys; Funktionelle Magnetresonanztomographie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, R.S.; Wittsack, H.J. [Universitaetsklinik Duesseldorf, Institut fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany); Notohamiprodjo, M. [Universitaetsklinik Tuebingen, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany)

    2015-12-15

    Interest in functional renal magnetic resonance imaging (MRI) has significantly increased in recent years. This review article provides an overview of the most important functional imaging techniques and their potential clinical applications for assessment of native and transplanted kidneys, with special emphasis on the clarification of renal tumors. (orig.) [German] Die funktionelle MRT der Nieren hat in den letzten Jahren zunehmend an Bedeutung gewonnen. In diesem Uebersichtsartikel werden die wichtigsten funktionellen Untersuchungstechniken vorgestellt und deren potenzielle klinische Bedeutung zur Evaluation von Nieren und Transplantatnieren hervorgehoben, wobei ein besonderes Augenmerk auf die Abklaerung von Nierentumoren gelegt wird. (orig.)

  9. Near-zero-field nuclear magnetic resonance

    CERN Document Server

    Ledbetter, Micah; Blanchard, John; Ring, Hattie; Ganssle, Paul; Appelt, Stephan; Bluemich, Bernhard; Pines, Alex; Budker, Dmitry

    2011-01-01

    We investigate nuclear magnetic resonance (NMR) in near-zero-field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J-coupling). This is in stark contrast to the high field case, where heteronuclear J-couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectra. Experimental results are in good agreement with first-order perturbation theory and with full numerical simulation when perturbation theory breaks down. We present simple rules for understanding the splitting patterns in near-zero-field NMR, which can be applied to molecules with non-trivial spectra.

  10. Near-zero-field nuclear magnetic resonance.

    Science.gov (United States)

    Ledbetter, M P; Theis, T; Blanchard, J W; Ring, H; Ganssle, P; Appelt, S; Blümich, B; Pines, A; Budker, D

    2011-09-02

    We investigate nuclear magnetic resonance (NMR) in near zero field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J coupling). This is in stark contrast to the high-field case, where heteronuclear J couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectra. Experimental results are in good agreement with first-order perturbation theory and with full numerical simulation when perturbation theory breaks down. We present simple rules for understanding the splitting patterns in near-zero-field NMR, which can be applied to molecules with nontrivial spectra.

  11. Clinical applications of cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C. [Hospital of Saint Raphael, Cardiac Diagnostic Unit, New Haven, CT (United States)], E-mail: bogmarcu@pol.net

    2006-10-15

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  12. Nanoscale nuclear magnetic resonance with chemical resolution

    Science.gov (United States)

    Aslam, Nabeel; Pfender, Matthias; Neumann, Philipp; Reuter, Rolf; Zappe, Andrea; Fávaro de Oliveira, Felipe; Denisenko, Andrej; Sumiya, Hitoshi; Onoda, Shinobu; Isoya, Junichi; Wrachtrup, Jörg

    2017-07-01

    Nuclear magnetic resonance (NMR) spectroscopy is a key analytical technique in chemistry, biology, and medicine. However, conventional NMR spectroscopy requires an at least nanoliter-sized sample volume to achieve sufficient signal. We combined the use of a quantum memory and high magnetic fields with a dedicated quantum sensor based on nitrogen vacancy centers in diamond to achieve chemical shift resolution in 1H and 19F NMR spectroscopy of 20-zeptoliter sample volumes. We demonstrate the application of NMR pulse sequences to achieve homonuclear decoupling and spin diffusion measurements. The best measured NMR linewidth of a liquid sample was ~1 part per million, mainly limited by molecular diffusion. To mitigate the influence of diffusion, we performed high-resolution solid-state NMR by applying homonuclear decoupling and achieved a 20-fold narrowing of the NMR linewidth.

  13. Enhancement of magnetic resonance imaging with metasurfaces

    CERN Document Server

    Slobozhanyuk, A P; Raaijmakers, A J E; Berg, C A T van den; Kozachenko, A V; Dubrovina, I A; Melchakova, I V; Kivshar, Yu S; Belov, P A

    2015-01-01

    Magnetic resonance imaging (MRI) is the cornerstone technique for diagnostic medicine, biology, and neuroscience. This imaging method is highly innovative, noninvasive and its impact continues to grow. It can be used for measuring changes in the brain after enhanced neural activity, detecting early cancerous cells in tissue, as well as for imaging nanoscale biological structures, and controlling fluid dynamics, and it can be beneficial for cardiovascular imaging. The MRI performance is characterized by a signal-to-noise ratio, however the spatial resolution and image contrast depend strongly on the scanner design. Here, we reveal how to exploit effectively the unique properties of metasurfaces for the substantial improvement of MRI efficiency. We employ a metasurface created by an array of wires placed inside the MRI scanner under an object, and demonstrate a giant enhancement of the magnetic field by means of subwavelength near-field manipulation with the metasurface, thus strongly increasing the scanner sen...

  14. Plasmon coupling of magnetic resonances in an asymmetric gold semishell

    Science.gov (United States)

    Ye, Jian; Kong, Yan; Liu, Cheng

    2016-05-01

    The generation of magnetic dipole resonances in metallic nanostructures is of great importance for constructing near-zero or even negative refractive index metamaterials. Commonly, planar two-dimensional (2D) split-ring resonators or relevant structures are basic elements of metamaterials. In this work, we introduce a three-dimensional (3D) asymmetric Au semishell composed of two nanocups with a face-to-face geometry and demonstrate two distinct magnetic resonances spontaneously in the visible-near infrared optical wavelength regime. These two magnetic resonances are from constructive and destructive hybridization of magnetic dipoles of individual nanocups in the asymmetric semishell. In contrast, complete cancellation of magnetic dipoles in the symmetric semishell leads to only a pronounced electric mode with near-zero magnetic dipole moment. These 3D asymmetric resonators provide new ways for engineering hybrid resonant modes and ultra-high near-field enhancement for the design of 3D metamaterials.

  15. A Gadolinium-containing Magnetic Resonance Image Contrast Agent Promotes Fibrocyte Differentiation

    OpenAIRE

    Vakil, Varsha; Sung, Joanna J.; Piecychna, Marta; Crawford, Jeffrey R.; Kuo, Philip; Abu-Alfa, Ali K.; Cowper, Shawn E.; Bucala, Richard; Gomer, Richard H.

    2009-01-01

    Gadolinium-containing magnetic resonance imaging contrast agents such as Omniscan are associated with Nephrogenic Systemic Fibrosis (NSF). To determine if Omniscan can affect the differentiation of monocytes into fibroblast-like cells called fibrocytes that are found in the fibrotic lesions of NSF, peripheral blood mononuclear cells (PBMCs) from NSF patients, hemodialysis patients without NSF, and healthy, renally sufficient controls were exposed to Omniscan in a standardized in vitro fibrocy...

  16. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  17. Magnetic Resonance Imaging Methods in Soil Science

    Science.gov (United States)

    Pohlmeier, A.; van Dusschoten, D.; Blümler, P.

    2009-04-01

    Magnetic Resonance Imaging (MRI) is a powerful technique to study water content, dynamics and transport in natural porous media. However, MRI systems and protocols have been developed mainly for medical purposes, i.e. for media with comparably high water contents and long relaxation times. In contrast, natural porous media like soils and rocks are characterized by much lower water contents, typically 0 benefit. Three strategies can be applied for the monitoring of water contents and dynamics in natural porous media: i) Dedicated high-field scanners (with vertical bore) allowing stronger gradients and faster switching so that shorter echo times can be realized. ii) Special measurement sequences using ultrashort rf- and gradient-pulses like single point imaging derivates (SPI, SPRITE)(1) and multi-echo methods, which monitor series of echoes and allow for extrapolation to zero time(2). Hence, the loss of signal during the first echo period may be compensated to determine the initial magnetization (= water content) as well as relaxation time maps simultaneously. iii) Finally low field( strategies will be given. References 1) Pohlmeier et al. Vadose Zone J. 7, 1010-1017 (2008) 2) Edzes et al., Magn. Res. Imag. 16, 185-196 (1998) 3) Raich H, and Blümler P, Concepts in Magn. Reson. B 23B, 16-25 (2004) 4) Pohlmeier et al. Magn. Res. Imag. doi:10.1016/j.mri.2008.06.007 (2008)

  18. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  19. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    Energy Technology Data Exchange (ETDEWEB)

    Braggion-Santos, Maria Fernanda, E-mail: ferbraggion@yahoo.com.br [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Koenigkam-Santos, Marcel [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Teixeira, Sara Reis [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Volpe, Gustavo Jardim [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Divisão de Cardiologia - Universidade Johns Hopkins, Baltimore (United States); Trad, Henrique Simão [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Schmidt, André [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-09-15

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility.

  20. Clinical application of functional magnetic resonance imaging

    CERN Document Server

    Alwatban, A Z W

    2002-01-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a ...

  1. Magnetic resonance imaging of granular materials

    Science.gov (United States)

    Stannarius, Ralf

    2017-05-01

    Magnetic Resonance Imaging (MRI) has become one of the most important tools to screen humans in medicine; virtually every modern hospital is equipped with a Nuclear Magnetic Resonance (NMR) tomograph. The potential of NMR in 3D imaging tasks is by far greater, but there is only "a handful" of MRI studies of particulate matter. The method is expensive, time-consuming, and requires a deep understanding of pulse sequences, signal acquisition, and processing. We give a short introduction into the physical principles of this imaging technique, describe its advantages and limitations for the screening of granular matter, and present a number of examples of different application purposes, from the exploration of granular packing, via the detection of flow and particle diffusion, to real dynamic measurements. Probably, X-ray computed tomography is preferable in most applications, but fast imaging of single slices with modern MRI techniques is unmatched, and the additional opportunity to retrieve spatially resolved flow and diffusion profiles without particle tracking is a unique feature.

  2. Magnetic resonance methods in fetal neurology.

    Science.gov (United States)

    Mailath-Pokorny, M; Kasprian, G; Mitter, C; Schöpf, V; Nemec, U; Prayer, D

    2012-10-01

    Fetal magnetic resonance imaging (MRI) has become an established clinical adjunct for the in-vivo evaluation of human brain development. Normal fetal brain maturation can be studied with MRI from the 18th week of gestation to term and relies primarily on T2-weighted sequences. Recently diffusion-weighted sequences have gained importance in the structural assessment of the fetal brain. Diffusion-weighted imaging provides quantitative information about water motion and tissue microstructure and has applications for both developmental and destructive brain processes. Advanced magnetic resonance techniques, such as spectroscopy, might be used to demonstrate metabolites that are involved in brain maturation, though their development is still in the early stages. Using fetal MRI in addition to prenatal ultrasound, morphological, metabolic, and functional assessment of the fetus can be achieved. The latter is not only based on observation of fetal movements as an indirect sign of activity of the fetal brain but also on direct visualization of fetal brain activity, adding a new component to fetal neurology. This article provides an overview of the MRI methods used for fetal neurologic evaluation, focusing on normal and abnormal early brain development. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. General review of magnetic resonance elastography.

    Science.gov (United States)

    Low, Gavin; Kruse, Scott A; Lomas, David J

    2016-01-28

    Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing "virtual palpation", MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration.

  4. Sinais de hipervascularização em imagens de ressonância magnética em metástases ósseas de carcinoma de células renais Signs of hypervascularization at magnetic resonance imaging in bone metastases from renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Leonir Terezinha Feltrin

    2009-06-01

    Full Text Available OBJETIVO: Avaliar a frequência de hipervascularização pela visualização de vasos no interior ou ao redor de metástases ósseas de carcinoma de células renais. MATERIAIS E MÉTODOS: Foram avaliados, retrospectivamente, exames de ressonância magnética de 13 pacientes com diagnóstico de carcinoma de células renais, com 15 lesões ósseas metastáticas, que não haviam sido submetidos a nenhum tratamento. RESULTADOS: Foram encontrados sinais de hipervascularização em 12 das 15 lesões (80%, sendo 6 na coluna lombar, 3 na bacia, 1 na coluna torácica, 1 na ulna e 1 na tíbia. CONCLUSÃO: A alta frequência de hipervascularização em metástases ósseas de carcinoma de células renais encontrada neste trabalho pode sugerir a etiologia renal, tornando-se muito útil na apresentação clínica usual de lesão óssea única com neoplasia primária desconhecida.OBJECTIVE: To evaluate the frequency of hypervascularization by visualizing vascular structures inside or around bone metastases from renal cell carcinoma. MATERIALS AND METHODS: Magnetic resonance imaging studies of 13 untreated patients with diagnosis of renal cell carcinoma and 15 metastatic bone lesions were retrospectively evaluated. RESULTS: Signs of hypervascularization were found in 12 of the 15 bone lesions (80%, 6 of them localized in the lumbar spine, 3 in the hip, 3 in the thoracic spine, 1 in the ulna and 1 in the tibia. CONCLUSION: The high frequency of hypervascularization of bone metastases from renal cell carcinoma found in the present study may suggest that the renal etiology is a useful parameter in the evaluation of a usual clinical presentation of a single bone lesion with unknown primary neoplasm.

  5. Biological effects of exposure to magnetic resonance imaging: an overview

    OpenAIRE

    Formica Domenico; Silvestri Sergio

    2004-01-01

    Abstract The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to a...

  6. Magnetic resonance elastography in the detection of hepatorenal syndrome in patients with cirrhosis and ascites

    Energy Technology Data Exchange (ETDEWEB)

    Low, Gavin [Cambridge University Hospitals NHS Foundation Trust Hospital, Department of Radiology, Addenbrooke' s Hospital, England (United Kingdom); University of Alberta, Edmonton, Alberta (Canada); University of Cambridge School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom); Owen, Nicola E.; Alexander, Graeme J.M. [Cambridge University Hospitals NHS Foundation Trust Hospital, Division of Gastroenterology and Hepatology, Addenbrooke' s Hospital, England (United Kingdom); Joubert, Ilse; Patterson, Andrew J.; Graves, Martin J. [Cambridge University Hospitals NHS Foundation Trust Hospital, Department of Radiology, Addenbrooke' s Hospital, England (United Kingdom); Lomas, David J. [Cambridge University Hospitals NHS Foundation Trust Hospital, Department of Radiology, Addenbrooke' s Hospital, England (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom)

    2015-10-15

    Hepatorenal syndrome (HRS) is the most lethal cause of renal impairment in cirrhosis. Magnetic resonance elastography (MRE) is a diagnostic test that characterises tissues based on their biomechanical properties. The aim of this study was to assess the feasibility of MRE for detecting HRS in cirrhotic patients. A prospective diagnostic investigation was performed. Renal MRE was performed on 21 hospitalised patients with cirrhosis and ascites. Six patients had HRS, one patient had non-HRS renal impairment, and 14 patients had normal renal function. The MRE-measured renal stiffness was compared against the clinical diagnosis as determined by clinical review alongside laboratory and radiologic results. The MRE-measured renal stiffness was significantly lower in patients with HRS (median stiffness of 3.30 kPa at 90 Hz and 2.62 kPa at 60 Hz) compared with patients with normal renal function (median stiffness of 5.08 kPa at 90 Hz and 3.41 kPa at 60 Hz) (P ≤ 0.014). For the detection of HRS, MRE had an area under the receiver operating characteristic curve of 0.94 at 90 Hz and 0.89 at 60 Hz. MRE had excellent inter-rater agreement, as assessed by Bland-Altman and intraclass correlation coefficient (> 0.9). MRE shows potential in the detection of HRS. (orig.)

  7. Bilateral Renal Mass-Renal Disorder: Tuberculosis

    Directory of Open Access Journals (Sweden)

    Ozlem Tiryaki

    2013-01-01

    Full Text Available A 30-year-old woman has presented complaining of weakness and fatigue to her primary care physician. The renal sonography is a routine step in the evaluation of new onset renal failure. When the renal masses have been discovered by sonography in this setting, the functional imaging may be critical. We reported a case about bilateral renal masses in a young female patient with tuberculosis and renal insufficiency. Magnetic resonance (MR has revealed the bilateral renal masses in patient, and this patient has been referred to our hospital for further management. The patient’s past medical and surgical history was unremarkable.

  8. Ferromagnetic resonance of particulate magnetic recording tapes

    Science.gov (United States)

    Netzelmann, U.

    1990-08-01

    The room-temperature ferromagnetic resonance (FMR) spectra of γ-Fe2O3, CrO2, and barium ferrite particulate magnetic recording tapes have been measured at microwave frequencies of 9.35 and 35 GHz for various orientations of the static and high-frequency magnetic fields with respect to the tape. For CrO2 tapes, the influence of the width of the angular distribution of the particle orientations on the FMR spectra has been studied from the nearly isotropic case up to the highly oriented case. Hysteretic behavior for a CrO2 tape as well as the effect of tape calendering for a γ-Fe2O3 tape has been observed by FMR. Experimental results are found to be in reasonable agreement with results of theoretical calculations based on a model of an ellipsoidal single-domain particle with both shape and magnetocrystalline anisotropy. Magnetostatic interaction inside the magnetic film has been introduced by expressing the total magnetostatic energy as a combination of a part dependent on particle shape and a part dependent on the shape of the tape. As a result of a comparison of experimental data with calculated data from the model, the magnetocrystalline easy axis of the CrO2 particles is found to be parallel with the particle axis.

  9. Spatial localization in nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Keevil, Stephen F [Department of Medical Physics, Guy' s and St Thomas' NHS Foundation Trust, Guy' s Hospital, London, SE1 9RT (United Kingdom); Division of Imaging Sciences, King' s College London, Guy' s Campus, London, SE1 9RT (United Kingdom)

    2006-08-21

    The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications. (topical review)

  10. Multidataset Refinement Resonant Diffraction, and Magnetic Structures.

    Science.gov (United States)

    Attfield, J Paul

    2004-01-01

    The scope of Rietveld and other powder diffraction refinements continues to expand, driven by improvements in instrumentation, methodology and software. This will be illustrated by examples from our research in recent years. Multidataset refinement is now commonplace; the datasets may be from different detectors, e.g., in a time-of-flight experiment, or from separate experiments, such as at several x-ray energies giving resonant information. The complementary use of x rays and neutrons is exemplified by a recent combined refinement of the monoclinic superstructure of magnetite, Fe3O4, below the 122 K Verwey transition, which reveals evidence for Fe(2+)/Fe(3+) charge ordering. Powder neutron diffraction data continue to be used for the solution and Rietveld refinement of magnetic structures. Time-of-flight instruments on cold neutron sources can produce data that have a high intensity and good resolution at high d-spacings. Such profiles have been used to study incommensurate magnetic structures such as FeAsO4 and β-CrPO4. A multiphase, multidataset refinement of the phase-separated perovskite (Pr0.35Y0.07Th0.04Ca0.04Sr0.5)MnO3 has been used to fit three components with different crystal and magnetic structures at low temperatures.

  11. Purely electric and magnetic dipole resonances in metamaterial dielectric resonators through perturbation theory inspired geometries

    CERN Document Server

    Campione, Salvatore; Warne, Larry K; Sinclair, Michael B

    2014-01-01

    In this paper we describe a methodology for tailoring the design of metamaterial dielectric resonators, which represent a promising path toward low-loss metamaterials at optical frequencies. We first describe a procedure to decompose the far field scattered by subwavelength resonators in terms of multipolar field components, providing explicit expressions for the multipolar far fields. We apply this formulation to confirm that an isolated high-permittivity cube resonator possesses frequency separated electric and magnetic dipole resonances, as well as a magnetic quadrupole resonance in close proximity to the electric dipole resonance. We then introduce multiple dielectric gaps to the resonator geometry in a manner suggested by perturbation theory, and demonstrate the ability to overlap the electric and magnetic dipole resonances, thereby enabling directional scattering by satisfying the first Kerker condition. We further demonstrate the ability to push the quadrupole resonance away from the degenerate dipole ...

  12. Renal arterial spin labeling magnetic resonance imaging in normal adults:a study with a 3.0 T scanner%3.0T磁共振动脉自旋标记技术在正常成人肾脏检查中的应用

    Institute of Scientific and Technical Information of China (English)

    张帆; 张雪林; 杨立; 沈洁; 高伟

    2013-01-01

    目的分析单次激发快速自旋回波-流动敏感反转恢复序列(SSFSE-FAIR)与平面回波-流动敏感反转恢复序列(EPI-FAIR)所测量的健康肾脏的相对血流量值(rBFV),评价两种动脉自旋标记(ASL)序列在正常肾脏检查中的应用价值。方法前瞻性分析40例符合纳入标准的受试者的rBFV。采用3.0T磁共振扫描仪扫描。按3种方式采集图像:EPI-FAIR屏气法、SSFSE-FAIR屏气法及SSFSE-FAIR自由呼吸法。结果SSFSE-FAIR自由呼吸法可定量区分肾脏皮髓质。皮质rBFV:111.48±9.23;髓质rBFV:94.98±3.38;SSFSE-FAIR屏气法及EPI-FAIR不能定量区分肾脏皮髓质。EPI-FAIR皮髓平均rBFV为178.50±17.17,95%置信区间:167.59~189.41。结论 SSFSE-FAIR屏气法及EPI-FAIR空间分辨率低,无法区分肾脏皮髓质,可粗略评价肾脏灌注情况。SSFSE-FAIR图像空间分辨率较高,可区分肾脏皮髓质结构,可初步评判肾脏皮髓质的灌注状态。%Objective To analyze the renal relative blood flow value (rBFV) and image quality in normal adults using single-shot fast spin echo, flow sensitive invention recovery (SSFSE-FAIR) magnetic resonance (MR) sequence and echo planar imaging, and flow sensitive invention recovery (EPI-FAIR) MR sequence, and assess its value for clinical application in routine renal examination. Methods Forty volunteers (25 male and 15 female adults, aged 30 to 62 years) with normal renal function were included in this prospective study. All the subjects underwent 3.0 Tesla MR scanning using 3 MR scan modes, namely breath-holding EPI-FAIR, breath-holding SSFSE-FAIR and free breathing SSFSE-FAIR. Results SSFSE-FAIR without breath-holding was capable of differentiating the renal cortex and medulla with the corresponding rBFVs of 111.48 ± 9.23 and 94.98 ± 3.38, respectively. Breath-holding SSFSE-FAIR and EPI-FAIR failed to distinguish the borders of the renal cortex and medulla. The EPI-FAIR rBFV of mixed

  13. Metabolic imaging of human kidney triglyceride content: reproducibility of proton magnetic resonance spectroscopy.

    Directory of Open Access Journals (Sweden)

    Sebastiaan Hammer

    Full Text Available OBJECTIVE: To assess the feasibility of renal proton magnetic resonance spectroscopy for quantification of triglyceride content and to compare spectral quality and reproducibility without and with respiratory motion compensation in vivo. MATERIALS AND METHODS: The Institutional Review Board of our institution approved the study protocol, and written informed consent was obtained. After technical optimization, a total of 20 healthy volunteers underwent renal proton magnetic resonance spectroscopy of the renal cortex both without and with respiratory motion compensation and volume tracking. After the first session the subjects were repositioned and the protocol was repeated to assess reproducibility. Spectral quality (linewidth of the water signal and triglyceride content were quantified. Bland-Altman analyses and a test by Pitman were performed. RESULTS: Linewidth changed from 11.5±0.4 Hz to 10.7±0.4 Hz (all data pooled, p<0.05, without and with respiratory motion compensation respectively. Mean % triglyceride content in the first and second session without respiratory motion compensation were respectively 0.58±0.12% and 0.51±0.14% (P = NS. Mean % triglyceride content in the first and second session with respiratory motion compensation were respectively 0.44±0.10% and 0.43±0.10% (P = NS between sessions and P = NS compared to measurements with respiratory motion compensation. Bland-Altman analyses showed narrower limits of agreement and a significant difference in the correlated variances (correlation of -0.59, P<0.05. CONCLUSION: Metabolic imaging of the human kidney using renal proton magnetic resonance spectroscopy is a feasible tool to assess cortical triglyceride content in humans in vivo and the use of respiratory motion compensation significantly improves spectral quality and reproducibility. Therefore, respiratory motion compensation seems a necessity for metabolic imaging of renal triglyceride content in vivo.

  14. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    Science.gov (United States)

    Shames, A. I.; Osipov, V. Yu; Boudou, J. P.; Panich, A. M.; von Bardeleben, H. J.; Treussart, F.; Vul', A. Ya

    2015-04-01

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ~5  ×  1018 spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp3 C-C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (~5  ×  1017 spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV-). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV- defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size dried supernatant of ultracentrifuged aqueous dispersion of FNDs, the NV- content is found to be reduced by one order of magnitude whereas the singlet defects content increases up to ~2  ×  1019 spins/g. In addition, another triplet-type defect, which is characterized by the g = 4.00 ‘forbidden’ line, appears. On reduction of the particle size below the 20 nm limit, the ‘allowed’ EPR lines become practically unobservable, whereas the ‘forbidden’ lines remain as a reliable fingerprint of the presence of NV- centers in small ND systems. The same size reduction causes the disappearance of the characteristic hyperfine satellites in the

  15. Surface Coil for Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Beatriz Taimy Ricardo Ferro

    2015-01-01

    Full Text Available Currently Magnetic Resonance Imaging (MRI, has become a vital tool for the clinical diagnosis of various diseases, especially in the Nervisos Central System and the Musculos keletal System. Coils(RF are an essential component in the generation of these images, are responsible for exciting thespins of nuclei in a sample and/or detect the resultant signal coming from them. The use of surface RF coils has increased considerably, because they have a high signal to noise ratio, a parameter that defines the quality of the image. In the present work, there was realized the theoretical design and practical implementation of a circular surface RF coil. The experimental prototype was optimized to be used in the tomograph Giroimag03  built in Medical Biophysics Center

  16. Magnetic resonance imaging in patients with panhypopituitarism

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Frezza, F. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Magnaldi, S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Proto, G. [Servizio di Endocrinologia, Ospedale Civile di Udine (Italy)

    1992-02-01

    Primary panhypopituitarism consists of functional deficiency of the anterior pituitary lobe, which appears during infancy or adolescence. The magnetic resonance findings in 10 patients with a history of primary hypopituitarism are presented. The findings include: reduced pituitary size in all cases; partially (8 cases) or totally (2 cases) empty sella; thin (4 cases), partially visible (3 cases) or absent (2 cases) pituitary stalk; absence of the posterior lobe in 9 cases; bright spot corresponding to an ectopic posterior lobe in 8 cases. These findings are similar to those already reported in pituitary dwarfism and may help understanding of the pathogenesis of the disease, which seems to be related to a pituitary stalk lesion. (orig.)

  17. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  18. Chest magnetic resonance imaging: a protocol suggestion*

    Science.gov (United States)

    Hochhegger, Bruno; de Souza, Vinícius Valério Silveira; Marchiori, Edson; Irion, Klaus Loureiro; Souza Jr., Arthur Soares; Elias Junior, Jorge; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Escuissato, Dante Luiz; Mançano, Alexandre Dias; Araujo Neto, César Augusto; Guimarães, Marcos Duarte; Nin, Carlos Schuler; Santos, Marcel Koenigkam; Silva, Jorge Luiz Pereira e

    2015-01-01

    In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation. PMID:26811555

  19. Cardiac magnetic resonance imaging: patient safety considerations.

    Science.gov (United States)

    Giroletti, Elio; Corbucci, Giorgio

    Magnetic Resonance Imaging (MRI) is widely used in medicine. In cardiology, it is used to assess congenital or acquired diseases of the heat: and large vessels. Unless proper precautions are taken, it is generally advisable to avoid using this technique in patients with implanted electronic stimulators, such as pacemakers and defibrillators, on account of the potential risk of inducing electrical currents on the endocardial catheters, since these currents might stimulate the heart at a high frequency, thereby triggering dangerous arrhythmias. In addition to providing some basic information on pacemakers, defibrillators and MRI, and on the possible physical phenomena that may produce harmful effects, the present review examines the indications given in the literature, with particular reference to coronary stents, artificial heart valves and implantable cardiac stimulators.

  20. [Gastric magnetic resonance study (methods, semiotics)].

    Science.gov (United States)

    Stashuk, G A

    2003-01-01

    The paper shows the potentialities of gastric study by magnetic resonance imaging (MRI). The methodic aspects of gastric study have been worked out. The MRI-semiotics of the unchanged and tumor-affected wall of the stomach and techniques in examining patients with gastric cancer of various sites are described. Using the developed procedure, MRI was performed in 199 patients, including 154 patients with gastric pathology and 45 control individuals who had no altered gastric wall. Great emphasis is placed on the role of MRI in the diagnosis of endophytic (diffuse) gastric cancer that is of priority value in its morphological structure. MRI was found to play a role in the diagnosis of the spread of a tumorous process both along the walls of the stomach and to its adjacent anatomic structures.

  1. Magnetic resonance imaging of the small bowel

    Energy Technology Data Exchange (ETDEWEB)

    Deeab, Dhafer A., E-mail: dhafer_ahmed@yahoo.co [Department of Radiology, St Mary' s Campus, Imperial College NHS Trust, London (United Kingdom); Dick, Elizabeth; Sergot, Antoni A.; Sundblon, Lauren; Gedroyc, Wady [Department of Radiology, St Mary' s Campus, Imperial College NHS Trust, London (United Kingdom)

    2011-02-15

    Magnetic Resonance Imaging of the Small Bowel (MR Enterography, or MRE) is becoming increasingly popular as the first imaging modality for the diagnosis and follow-up of small bowel diseases. The inherent advantages of MRI, including excellent soft tissue contrast, multiplanar capability and lack of ionising radiation are well known. In addition, the use of luminal contrast agents in MRE has the added advantage of demonstrating the lumen and the wall directly, something not possible to achieve with conventional small bowel barium follow-through imaging. This review will highlight recent technical advances to this low cost, simple technique which is easily achievable in all hospitals. It will also review normal and abnormal radiological findings and highlight the value of this technique to both the clinician and patient alike in the investigation of small bowel disease.

  2. Magnetic resonance imaging of the adrenal

    Energy Technology Data Exchange (ETDEWEB)

    Reinig, J.W.; Doppmann, J.L.

    1986-04-01

    Magnetic resonance imaging (MRI) of the adrenals was performed on 50 subjects: 5 normal volunteers, 6 Cushing patients with bilateral adrenal hyperplasia, 14 patients with adrenal adenomas, 3 with adrenal carcinomas, 15 with pheochromocytomas and 7 with metastatic disease to the adrenal. The normal and hyperplastic adrenal glands were imaged in all cases. Using the signal intensity of the adrenals on a T2 weighted image, various forms of adrenal pathology could be differentiated. A ratio of signal intensity of the adrenal mass to the liver was utilized and allowed the differentitaion of adrenal adenomas from adrenal carcinomas, pheochromocytomas and metastases. Using the same ratio, metastases could be distinguished from pheochromocytomas as well. MRI appears to be particularly valuable in distinguishing clinically silent adrenal metastases from nonfunctioning adrenal adenomas.

  3. Functional magnetic resonance imaging studies of language.

    Science.gov (United States)

    Small, Steven L; Burton, Martha W

    2002-11-01

    Functional neuroimaging of language builds on almost 150 years of study in neurology, psychology, linguistics, anatomy, and physiology. In recent years, there has been an explosion of research using functional imaging technology, especially positron emission tomography (PET) and functional magnetic resonance imaging (fMRI), to understand the relationship between brain mechanisms and language processing. These methods combine high-resolution anatomic images with measures of language-specific brain activity to reveal neural correlates of language processing. This article reviews some of what has been learned about the neuroanatomy of language from these imaging techniques. We first discuss the normal case, organizing the presentation according to the levels of language, encompassing words (lexicon), sound structure (phonemes), and sentences (syntax and semantics). Next, we delve into some unusual language processing circumstances, including second languages and sign languages. Finally, we discuss abnormal language processing, including developmental and acquired dyslexia and aphasia.

  4. Fetal Cerebral Magnetic Resonance Imaging Beyond Morphology.

    Science.gov (United States)

    Jakab, András; Pogledic, Ivana; Schwartz, Ernst; Gruber, Gerlinde; Mitter, Christian; Brugger, Peter C; Langs, Georg; Schöpf, Veronika; Kasprian, Gregor; Prayer, Daniela

    2015-12-01

    The recent technological advancement of fast magnetic resonance imaging (MRI) sequences allowed the inclusion of diffusion tensor imaging, functional MRI, and proton MR spectroscopy in prenatal imaging protocols. These methods provide information beyond morphology and hold the key to improving several fields of human neuroscience and clinical diagnostics. Our review introduces the fundamental works that enabled these imaging techniques, and also highlights the most recent contributions to this emerging field of prenatal diagnostics, such as the structural and functional connectomic approach. We introduce the advanced image processing approaches that are extensively used to tackle fetal or maternal movement-related image artifacts, and which are necessary for the optimal interpretation of such imaging data. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Magnetic resonance imaging of facial muscles

    Energy Technology Data Exchange (ETDEWEB)

    Farrugia, M.E. [Department of Clinical Neurology, University of Oxford, Radcliffe Infirmary, Oxford (United Kingdom)], E-mail: m.e.farrugia@doctors.org.uk; Bydder, G.M. [Department of Radiology, University of California, San Diego, CA 92103-8226 (United States); Francis, J.M.; Robson, M.D. [OCMR, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford (United Kingdom)

    2007-11-15

    Facial and tongue muscles are commonly involved in patients with neuromuscular disorders. However, these muscles are not as easily accessible for biopsy and pathological examination as limb muscles. We have previously investigated myasthenia gravis patients with MuSK antibodies for facial and tongue muscle atrophy using different magnetic resonance imaging sequences, including ultrashort echo time techniques and image analysis tools that allowed us to obtain quantitative assessments of facial muscles. This imaging study had shown that facial muscle measurement is possible and that useful information can be obtained using a quantitative approach. In this paper we aim to review in detail the methods that we applied to our study, to enable clinicians to study these muscles within the domain of neuromuscular disease, oncological or head and neck specialties. Quantitative assessment of the facial musculature may be of value in improving the understanding of pathological processes occurring within facial muscles in certain neuromuscular disorders.

  6. Breast conserving therapy and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Tsuneaki; Masuda, Yu; Hachiya, Junichi; Nitatori, Toshiaki; Fukushima, Hisayoshi; Uchigasaki, Shinya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1996-12-01

    Recently, breast conserving therapy has been widely accepted in our country. The extensive intraductal component (EIC) is a serious problem in breast conserving therapy, because it is well-known that EIC frequently causes locoregional recurrence in preserved breast parenchyma. Magnetic resonance imaging (MRI) is a useful method for detecting breast masses due to its excellent contrast resolution. We studied the application of MRI to detection of intraductal spread in twenty-two patients. All cases were revealed invasive cancer with intraductal spread by histopathological examination. MRI findings of intraductal spread can be divided into two major groups. One is daugter nodules or strand-like enhancement and the other is bridging enhancement. We also reffered to the preliminary study of MR-guiding transcutaneous aspiration biopsy of mammographically and clinically occult breast masses. (author)

  7. Quantum information processing through nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Bulnes, J.D.; Sarthour, R.S.; Oliveira, I.S. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Bonk, F.A.; Azevedo, E.R. de; Bonagamba, T.J. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica; Freitas, J.C.C. [Espirito Santo Univ., Vitoria, ES (Brazil). Dept. de Fisica

    2005-09-15

    We discuss the applications of Nuclear Magnetic Resonance (NMR) to quantum information processing, focusing on the use of quadrupole nuclei for quantum computing. Various examples of experimental implementation of logic gates are given and compared to calculated NMR spectra and their respective density matrices. The technique of Quantum State Tomography for quadrupole nuclei is briefly described, and examples of measured density matrices in a two-qubit I = 3/2 spin system are shown. Experimental results of density matrices representing pseudo-Bell states are given, and an analysis of the entropy of theses states is made. Considering an NMR experiment as a depolarization quantum channel we calculate the entanglement fidelity and discuss the criteria for entanglement in liquid state NMR quantum information. A brief discussion on the perspectives for NMR quantum computing is presented at the end. (author)

  8. Magnetic resonance urography by virtual reality modelling.

    Science.gov (United States)

    Beigi, Navid; Sangild, Thomas; Terkildsen, Søren Vorre; Deding, Dorthe; Stødkilde-Jørgensen, Hans; Pedersen, Michael

    2003-01-01

    The purpose of this study was to create a 3D visualization of the urinary tract by a novel virtual reality approach, and to evaluate the usefulness of this method for papillary classification as compared with 2D urogram obtained by maximum intensity projection (MIP). In one healthy pig, magnetic resonance urography was performed using a T1-weighted 3D gradient echo pulse sequence. Post-processing was performed by means of an MIP algorithm and by using 3D virtual reality modelling, followed by manual classification of papillae as being either simple or compound. The 2D MIP urogram demonstrated 6 simple and 6 compound papillae, whereas the 3D urogram demonstrated 5 simple and 7 compound papillae. In both urograms, some papillae were unsuccessfully classified. The possibility of using virtual reality devices allowed 3D rotation and offered additional diagnostic information. However, further studies should reveal its feasibility in diseased kidneys.

  9. Stafne bone cavity--magnetic resonance imaging.

    Science.gov (United States)

    Segev, Yoram; Puterman, Max; Bodner, Lipa

    2006-07-01

    A case of Stafne bone cavity (SBC) affecting the body of the mandible of a 51-year-old female is reported. The imaging modalities included panoramic radiograph, computed tomography (CT) and magnetic resonance (MR) imaging. Panoramic radiograph and CT were able to determine the outline of the cavity and its three dimensional shape, but failed to precisely diagnose the soft tissue content of the cavity. MR imaging demonstrated that the bony cavity is filled with soft tissue that is continuous and identical in signal with that of the submandibular salivary gland. Based on the MR imaging a diagnosis of SBC was made and no further studies or surgical treatment were initiated. MR imaging should be considered the diagnostic technique in cases where SBC is suspected. Recognition of the lesion should preclude any further treatment or surgical exploration.

  10. Magnetic resonance imaging of optic nerve

    Directory of Open Access Journals (Sweden)

    Foram Gala

    2015-01-01

    Full Text Available Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI, plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies.

  11. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  12. Magnetic resonance imaging of brain death

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.H.; Nathanson, J.A.; Fox, A.J.; Pelz, D.M.; Lownie, S.P.

    1995-06-01

    In order to demonstrate the magnetic resonance imaging (MRI) appearance of the brain in patients with clinical brain death, high-field MRI was performed on 5 patients using conventional T1-weighted and T2-weighted imaging. The study showed MRI exhibited similar features for all of the patients, features which were not found in MRI of comatose patients who were not clinically brain dead. It was stated that up to now the most important limitation in MRI of patients with suspected brain death has been the extreme difficulty of moving them out of the intensive care setting. If this problem can be overcome, and it appears possible with with the advent of MRI-compatible ventilators and noninvasive monitoring, MRI could become an excellent alternative for confirming clinical diagnosis of brain death for such patients. 15 refs., 3 figs.

  13. Magnetic resonance imaging of the heart.

    Science.gov (United States)

    Tscholakoff, D; Higgins, C B

    1985-01-01

    Magnetic resonance imaging (MRI) is a completely noninvasive technique for the evaluation of the cardiovascular system. With a multi-section technique and the spin echo pulse sequence the entire heart can be examined within six to ten minutes. All our cardiac MR studies were performed with electrocardiographic (ECG) gating, to obtain adequate resolution of the cardiac structures. With this technique, patients and animals with a variety of cardiac abnormalities were studied. The examined pathologic conditions included acute and chronic myocardial infarctions and their complications, hypertrophic and congestive cardiomyopathies, congenital heart diseases and pericardial diseases. MRI offers an enormous potential for cardiovascular diagnosis, even beyond the demonstration of pathoanatomy, because of the capability for direct tissue characterization and blood flow measurements.

  14. Quantum information processing and nuclear magnetic resonance

    CERN Document Server

    Cummins, H K

    2001-01-01

    as spectrometer pulse sequence programs. Quantum computers are information processing devices which operate by and exploit the laws of quantum mechanics, potentially allowing them to solve problems which are intractable using classical computers. This dissertation considers the practical issues involved in one of the more successful implementations to date, nuclear magnetic resonance (NMR). Techniques for dealing with systematic errors are presented, and a quantum protocol is implemented. Chapter 1 is a brief introduction to quantum computation. The physical basis of its efficiency and issues involved in its implementation are discussed. NMR quantum information processing is reviewed in more detail in Chapter 2. Chapter 3 considers some of the errors that may be introduced in the process of implementing an algorithm, and high-level ways of reducing the impact of these errors by using composite rotations. Novel general expressions for stabilising composite rotations are presented in Chapter 4 and a new class o...

  15. Magnetic resonance imaging of traumatic cervical injury

    Energy Technology Data Exchange (ETDEWEB)

    Juhng, S. K.; Lee, K. S.; Sohn, K. J.; Choi, S. S.; Won, J. J. [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    To evaluate magnetic resonance imaging (MRI) findings of cevical injuries. MRI studies of 34 patients with cervical spinal injuries were analyzed retrospectively. All MRI scans were obtained with an 1.0T superconductive MRI scanner (Siemens Magnetom 42SPE) and their findings were analyzed regarding the spinal cord, bony spine, ligaments, and intervertebral disks. A variety of abnormal findings were detected: 25 cord abnormalities including cord compression (15 cases), cord edema (4 cases), syringomyelia (4 cases), myelomalacia (1 case), and hemorrhagic contusion (1 case), 18 ligamentous injuries, 22 disk herniations (9 post-traumatic, 13 chronic degenerative), 11 spine fractures, and 4 subluxations. MRI is useful in evaluating the spinal cord itself, in depicting ligamentous injuries, in establishing the presence of disc herniation, and in assessing the alignment of cervical spine.

  16. Nuclear magnetic resonance imaging of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Modic, M.T.; Weinstein, M.A.; Pavlicek, W.; Starnes, D.L.; Duchesneau, P.M.; Boumphrey, F.; Hardy, R.J. Jr.

    1984-01-01

    Forty subjects were examined to determine the accuracy and clinical usefulness of nuclear magnetic resonance (NMR) examination of the spine. The NMR images were compared with plain radiographs, high-resolution computed tomograms, and myelograms. The study included 15 patients with normal spinal cord anatomy and 25 patients whose pathological conditions included canal stenosis, herniated discs, metastatic tumors, primary cord tumor, trauma, Chiari malformations, syringomyelia, and developmental disorders. Saturation recovery images were best in differentiating between soft tissue and cerebrospinal fluid. NMR was excellent for the evaluation of the foramen magnum region and is presently the modality of choice for the diagnosis of syringomyelia and Chiari malformation. NMR was accurate in diagnosing spinal cord trauma and spinal canal block.

  17. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo [Sao Paulo Univ. (USP), SP (Brazil). Instituto do Coracao. Setor de Tomografia Computarizada e Ressonancia Magnetica Cardiovascular]. E-mail: rochitte@incor.usp.br; Kim, Raymond J. [Duke Cardiovascular Magnetic Resonance Center, Durham, NC (United States); Tassi, Eduardo Marinho [Diagnosticos da America S.A., Rio de Janeiro, RJ (Brazil). Sector of Cardiovascular Magnetic Resonance and Computed Tomography

    2007-03-15

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  18. Prostate magnetic resonance imaging: challenges of implementation.

    Science.gov (United States)

    Loch, Ronald; Fowler, Kathryn; Schmidt, Ryan; Ippolito, Joseph; Siegel, Cary; Narra, Vamsi

    2015-01-01

    Prostate cancer is among the most common causes of cancer and cancer deaths in men. Screening methods and optimal treatments have become controversial in recent years. Prostate magnetic resonance imaging (MRI) is gaining popularity as a tool to assist diagnosis, risk assessment, and staging. However, implementation into clinical practice can be difficult, with many challenges associated with image acquisition, postprocessing, interpretation, reporting, and radiologic-pathologic correlation. Although state-of-the-art technology is available at select sites for targeting tissue biopsy and interpreting multiparametric prostate MRI, many institutions struggle with adapting this new technology into an efficient multidisciplinary model of patient care. This article reviews several of the challenges that radiologists should be aware of when integrating prostate MRI into their clinical practice.

  19. Magnetic resonance imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Sandrasegaran, K. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Saifuddin, A. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Coral, A. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Butt, W.P. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom))

    1994-05-01

    Five cases of septic sacroiliitis diagnosed by magnetic resonance imaging (MRI) are presented. Imaging was performed between 2 and 14 days after onset of symptoms and consisted of varying combinations of coronal short tau inversion recovery (STIR), axial T2-weighted spin echo (SE), and coronal and axial pre- and postcontrast T1-weighted SE scans. Abnormalities included demonstration of sacroiliac joint effusions, bone oedema and adjacent inflammation as high signal on STIR and T2-weighted SE scans, and identification of abscesses in two cases as rim-enhancing lesions anterior to the joint on gadolinium-enhanced T1-weighted SE scans. The role of MRI and other forms of imaging in septic sacroiliitis is discussed. (orig.)

  20. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    -angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...... and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...... in a transgenic mouse model. The last manuscript presents a new method for in vivo cell labeling. This method could find use in studying the metastatic spread of cancer cells throughout the body....

  1. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  2. Optimal sequence for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Kanzaki, Hiroshi; Akata, Soichi; Ozuki, Taizo; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2001-09-01

    Magnetic resonance cholangiopancreatography (MRCP) has attracted attention as a useful examination for abnormalities of the pancreaticobiliary system, because it is a simple procedure. Since there are few detailed reports on optimal sequences for MRCP, we attempted to clarify the topic. The magnetic resonance imaging (MRI) equipment we used was a 1.0 Tesla super-conductive type. A fast spin echo (16 echo train) was used, and the echo space was set at 17 msec. TE was changed from 17 msec to 272 msec in 17 msec increments. TR was changed from 1,000 msec to 9,000 msec by 1,000 msec increments. Bile juice which had been collected from the PTCD tube of a patient with common bile duct cancer, was put in a test tube of 10 mm internal diameter. Saline was used as a substitute for pancreatic juice, because collection of pancreatic juice was difficult. Fat was used for contrast. Each signal intensity inside the test tube was measured and evaluated. We attempted to evaluate the signal of gastric juice by adding blueberry juice, making use of its manganese ion (Mn{sup ++}). With longer TR, the signal intensities of bile and pancreas juice increased. As TE became longer, the signal intensities of bile and pancreas juice decreased slightly, while that of fat decreased much more. In MRCP, it is necessary to set up a long TE to increase the relative signal intensity difference of fat in bile and pancreas juice. The signal intensity of gastric juice was made to disappear by the addition of blueberry juice diluted to a ratio of 1:3. (author)

  3. Observation of spin diffusion in zero-field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Suter, D.; Jarvie, T.P.; Sun, B.; Pines, A.

    1987-07-06

    We report the measurement of spin diffusion at zero field, observed by two-dimensional deuterium magnetic resonance of a polycrystalline sample. This demonstrates for the first time an appealing feature of pulsed zero-field magnetic resonance, namely the potential for structure determination in solids without the need for single crystals or oriented samples.

  4. Resonances and dipole moments in dielectric, magnetic, and magnetodielectric cylinders

    DEFF Research Database (Denmark)

    Dirksen, A.; Arslanagic, Samel; Breinbjerg, Olav

    2011-01-01

    An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis...... of metamaterials, is given with an emphasis on their strength, bandwidth, and isolation....

  5. Monitoring Locally Induced Hyperthermia with Magnetic Resonance Imaging

    NARCIS (Netherlands)

    M.W. Vogel (M.)

    2005-01-01

    markdownabstract__Abstract__ Magnetic resonance thermometry is a relatively new and unique technology for non-invasive monitoring of (local) therapeutic temperature changes that is not yet in common use. Temperature measurements using magnetic resonance heat thermometry can be performed in several

  6. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J.N.; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  7. Nuclear magnetic resonance in environmental engineering: principles and applications.

    NARCIS (Netherlands)

    Lens, P.N.L.; Hemminga, M.A.

    1998-01-01

    This paper gives an introduction to nuclear magnetic resonance spectroscopy (NMR) and magnetic resonance imaging (MRI) in relation to applications in the field of environmental science and engineering. The underlying principles of high resolution solution and solid state NMR, relaxation time measure

  8. Plasma-induced magnetic responses during nonlinear dynamics of magnetic islands due to resonant magnetic perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Seiya, E-mail: n-seiya@kobe-kosen.ac.jp [Kobe City College of Technology, Kobe, Hyogo 651-2194 (Japan)

    2014-12-15

    Resonant magnetic perturbations (RMPs) produce magnetic islands in toroidal plasmas. Self-healing (annihilation) of RMP-induced magnetic islands has been observed in helical systems, where a possible mechanism of the self-healing is shielding of RMP penetration by plasma flows, which is well known in tokamaks. Thus, fundamental physics of RMP shielding is commonly investigated in both tokamaks and helical systems. In order to check this mechanism, detailed informations of magnetic island phases are necessary. In experiments, measurement of radial magnetic responses is relatively easy. In this study, based on a theoretical model of rotating magnetic islands, behavior of radial magnetic fields during the self-healing is investigated. It is confirmed that flips of radial magnetic fields are typically observed during the self-healing. Such behavior of radial magnetic responses is also observed in LHD experiments.

  9. Compact electrically detected magnetic resonance setup

    Directory of Open Access Journals (Sweden)

    Michael Eckardt

    2015-04-01

    Full Text Available Electrically detected magnetic resonance (EDMR is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

  10. Oedema in the Lumbar Subcutaneous Fat, on Routine Magnetic Resonance Imaging, of Patients with No History of Cardiac, Renal or Hepatic Disease, Is Significantly Associated with Obesity and Age

    Directory of Open Access Journals (Sweden)

    WM West

    2015-05-01

    Full Text Available Objectives: To investigate the association between oedema in the subcutaneous fat of the lumbar region during routine magnetic resonance imaging (MRI and patients’ age, gender and body mass index (BMI. Methods: One hundred and forty-nine consecutive examinations of 95 females and 54 males, 18 years and older, scanned at 1.5T between October 1, 2010, and December 31, 2010, were reviewed. Presence and extent of oedema were determined. Oedema was sized on the anatomical segments. Data were analysed using tests for means, odd’s ratio (OR, Chi-squared test, McNemar’s test, linear and backward stepwise multiple regression and analysis of variance (ANOVA. Results: Patients with oedema had significantly higher BMI (30.3 kg/m2 vs 24.9 kg/m2, p < 0.001, and were older (49.9 years vs 43.9 years, p = 0.01 than those without oedema. The OR for oedema in obese vs non-obese patients was 8.6. The Chi-squared and McNemar tests were significant, p = 0 and p < 0.001, respectively. Body mass index and age predicted oedema on backward stepwise regression and, on ANOVA, at 23.6% and 4.7%, respectively. Males were marginally less likely to have oedema (p = 0.056 and had marginally less oedema (p = 0.056 than females. Conclusion: Body mass index and age, but not gender, predict oedema. Body mass index predicts oedema five times as much as age.

  11. Magnetic resonance spectroscopy as a diagnostic modality for carcinoma thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nikhil [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)], E-mail: nikhil_ms26@yahoo.co.in; Kakar, Arun K. [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Chowdhury, Veena [Department of Radiodiagnosis, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Gulati, Praveen [MR Centre, A-23 Green Park, New Delhi (India); Shankar, L. Ravi [Department of Radioiodine Uptake and Imaging, Institute of Nucler Medicine and Allied Sciences (INMAS), Timarpur, New Delhi (India); Vindal, Anubhav [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)

    2007-12-15

    Aim: The aim of this study was to observe the findings of magnetic resonance spectroscopy of solitary thyroid nodules and its correlation with histopathology. Materials and methods: In this study, magnetic resonance spectroscopy was carried out on 26 patients having solitary thyroid nodules. Magnetic resonance spectroscopy (MRS) was performed on a 1.5 T super conductive system with gradient strength of 33 mTs. Fine needle aspiration cytology was done after MRS. All 26 patients underwent surgery either because of cytopathologically proven malignancy or because of cosmetic reasons. Findings of magnetic resonance spectroscopy were compared with histopathology of thyroid specimens. Results and conclusion: It was seen that presence or absence of choline peak correlates very well with presence or absence of malignant foci with in the nodule (sensitivity = 100%; specificity = 88.88%). These results indicate that magnetic resonance spectroscopy may prove to be an useful diagnostic modality for carcinoma thyroid.

  12. Torque-mixing magnetic resonance spectroscopy (Conference Presentation)

    Science.gov (United States)

    Losby, Joseph; Fani Sani, Fatemeh; Grandmont, Dylan T.; Diao, Zhu; Belov, Miro; Burgess, Jacob A.; Compton, Shawn R.; Hiebert, Wayne K.; Vick, Doug; Mohammad, Kaveh; Salimi, Elham; Bridges, Gregory E.; Thomson, Douglas J.; Freeman, Mark R.

    2016-10-01

    An optomechanical platform for magnetic resonance spectroscopy will be presented. The method relies on frequency mixing of orthogonal RF fields to yield a torque amplitude (arising from the transverse component of a precessing dipole moment, in analogy to magnetic resonance detection by electromagnetic induction) on a miniaturized resonant mechanical torsion sensor. In contrast to induction, the method is fully broadband and allows for simultaneous observation of the equilibrium net magnetic moment alongside the associated magnetization dynamics. To illustrate the method, comprehensive electron spin resonance spectra of a mesoscopic, single-crystal YIG disk at room temperature will be presented, along with situations where torque spectroscopy can offer complimentary information to existing magnetic resonance detection techniques. The authors are very grateful for support from NSERC, CRC, AITF, and NINT. Reference: Science 350, 798 (2015).

  13. Italian registry of cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Francone, Marco [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Dipartimento di Scienze Cliniche Applicate e Biotecnologie, Università di L’Aquila (Italy); Cademartiri, Filippo [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pontone, Gianluca [IRCCS Centro Cardiologico Monzino (Italy); Lovato, Luigi [Policlinico S. Orsola Bologna (Italy); Matta, Gildo [Azienda ospedaliera G Brotzu Cagliari (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, Milan (Italy); Maffei, Erica [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pradella, Silvia [Azienda Ospedaliera Universitaria Careggi (Italy); Carbone, Iacopo [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Marano, Riccardo [Policlinico Gemelli, Università Cattolica Roma (Italy); Bacigalupo, Lorenzo [Ospedale Galliera, Genova (Italy); Chiodi, Elisabetta [Ospedale S. Anna Ferrara (Italy); Donato, Rocco [Azienda Ospedaliera Universitaria G. Martino, Me (Italy); Sbarbati, Stefano [Ospedale Madre Giuseppina Vannini, Roma (Italy); De Cobelli, Francesco [IRCCS S. Raffaele, Università Vita Salute, Milano (Italy); Di Renzi, Paolo [Fate Bene Fratelli Isola tiberina, Roma (Italy); Ligabue, Guido; Mancini, Andrea [Azienda Ospedaliera-Universitaria Policlinico di Modena (Italy); Palmieri, Francesco [Diparimento di Diagnostica per immagini e radiologia interventistica, Ospedale S. Maria delle Grazie, Pozzuoli, Napoli (Italy); and others

    2014-01-15

    Objectives: Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods: Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1–92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results: Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions: CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile.

  14. Experiments in Nuclear Magnetic Resonance Microscopy

    Science.gov (United States)

    Lee, Yong; Lu, Wei; Choi, J.-H.; Chia, H. J.; Mirsaidov, U. M.; Guchhait, S.; Cambou, A. D.; Cardenas, R.; Park, K.; Markert, J. T.

    2006-03-01

    We report our group's effort in the construction of an 8-T, ^3 He cryostat based nuclear magnetic resonance force microscope (NMRFM). The probe has two independent 3-D of piezoelectric x-y-z positioners for precise positioning of a fiber optic interferometer and a sample/gradient-producing magnet with respect to a micro-cantilever. The piezoelectric positioners have a very uniform controllable step size with virtually no backlash. A novel RF tuning circuit board design is implemented which allows us to simply swap out one RF component board with another for experiments involving different nuclear species. We successfully fabricated and are characterizing 50μm x50μm x0.2μm double torsional oscillators. We have also been characterizing ultrasoft cantilevers whose spring constant is on the order of 10-4 N/m. We also report NMRFM data for ammonium dihydrogen phosphate(ADP) at room temperature using our 1.2-T system. Observed features include the correct shift of the NMR peak with carrier frequency, increases in signal amplitude with both RF field strength and frequency modulation amplitude, and signal oscillation (spin nutation) as a function of tipping RF pulse length. Experiments in progress on NH4MgF3 (at 1.2 T) and MgB2 (at 8.1 T) will also be briefly reviewed. Robert A. Welch Foundation grant No.F-1191 and the National Science Foundation grant No. DMR-0210383.

  15. Parametric resonance induced chaos in magnetic damped driven pendulum

    Energy Technology Data Exchange (ETDEWEB)

    Khomeriki, Giorgi, E-mail: giokhomeriki123@gmail.com

    2016-07-15

    A damped driven pendulum with a magnetic driving force, appearing from a solenoid, where ac current flows is considered. The solenoid acts on the magnet, which is located at a free end of the pendulum. In this system the existence and interrelation of chaos and parametric resonance is theoretically examined. Derived analytical results are supported by numerical simulations and conducted experiments. - Highlights: • A damped magnetic pendulum is considered driven by off resonant magnetic field. • Our system is chaotic only when the conditions for parametric resonance are fulfilled. • Conducted experiments give a good agreement with theory and numerical simulations. • Calculated Lyapunov exponents are compared with parametric instability growth rates.

  16. Electric and magnetic dipole couplings in split ring resonator metamaterials

    Institute of Scientific and Technical Information of China (English)

    Fan Jing; Sun Guang-Yong; and Zhu Wei-Ren

    2011-01-01

    In this paper,the electric and the magnetic dipole couplings between the outer and the inner rings of a single split ring resonator (SRR) are investigated.We numerically demonstrate that the magnetic resonance frequency can be substantially modified by changing the couplings of the electric and magnetic dipoles,and give a theoretical expression of the magnetic resonance frequency.The results in this work are expected to be conducive to a deeper understanding of the SRR and other similar metamaterials,and provide new guidance for complex metamaterials design with a tailored electromagnetic response.

  17. Clinical application of functional magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Alwatban, Adnan Z.W

    2002-07-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the author except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a transtympanic electrode implanted onto the surface of the cochlea. This approach would however, result in electromotive forces (EMFs) being induced by the time varying magnetic field, which would lead to current flow and heating, as well as deflection of the metallic electrode within the static magnetic field, and image distortion due to the magnetic susceptibility difference. A gold-plated tungsten electrode with a zero magnetic susceptibility was developed to avoid image distortion. Used with carbon leads and a carbon reference pad, it enabled safe, distortion-free fMRI studies of deaf subjects. The study revealed activation of the primary auditory cortex. This fMRI procedure can be used to demonstrate whether the auditory pathway is fully intact, and may provide a useful method for pre-operative assessment of candidates for cochlear implantation. Glucose is the energy source on which the function of the human brain is entirely dependent. Failure to

  18. Magnetic resonance imaging in neurologic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Hyun; Han, Man Chung; Wan, Chu Wan; Myung, Ho Jin; Choi, Kil Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Ahn, Chang Beom; Oh, Chang Hyun; Cho, Zang Hee [Koear Advanced Institute of Science, Seoul (Korea, Republic of)

    1985-02-15

    Magnetic resonance (MR) imaging with 0.15 Tesla resistive magnet developed by Korea Advanced Institute of Science were performed in 27 patients with various neurologic diseases and compared with x-ray computed tomography (CT). The purpose of the paper is to evaluate the image quality, the diagnostic value and limitation, and the optimal pulse sequence of MR imagings with a resistive magnet. The MR images were obtained by using a variety of pulse sequence with spin echo technique including saturation recovery. T2-weighted spin echo, and/or inversion recovery with various pulse repetition (TR) and echo delay (TE) times. The MR imaging demonstrated the capability of detecting the lesions shown on CT in al cases and also detected an additional finding in one case (multiple sclerosis) which was not seen on CT. The MR imaging appeared to be more useful than CT in the evaluation of syringomyelia of spinal cord and white matter disease, while it failed to demonstrated small calcific lesion or inflammatory nodule (less than 1 cm) shown on CT and has shown somewhat poor contrast resolution in the case of meingloma. The spatial resolution of saturation recovery images was similar or superior to CT, whereas the contrast resolution of saturation recovery was inferior to CT. While the saturation recovery images have shown false negative findings in 5 patients (19%), the inversion recovery and T2-weighted spin echo have shown consistently positive findings. The inversive recovery and T2-weighted spin echo images demonstrated better contrast discrimination between normal and pathologic conditions than the saturation recovery images, but somewhat poorer spatial resolution. Authors suggest that the MR images of both the saturation recovery with 300/30 and T2-weighted spin echo with 1000/90 be used as a routine procedure and additional inversion recovery of 1300/300/30 sequence as a option if white matter disease is suspected.

  19. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...... and wherein said first conductive wire and said one or more capacitors are located outside of said internal volume, wherein the internal volume of the hollow waveguide defines an imaging volume or sample volume....

  20. Controlling interactions between highly magnetic atoms with Feshbach resonances.

    Science.gov (United States)

    Kotochigova, Svetlana

    2014-09-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic (7)S3 chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on dysprosium and erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P-states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  1. Controlling interactions between highly-magnetic atoms with Feshbach resonances

    CERN Document Server

    Kotochigova, Svetlana

    2014-01-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic $^7$S$_3$ chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on Dysprosium and Erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  2. Evaluation of magnetic resonance angiography in detection of gastric varices

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Suga, Toshihiro [Sapporo Kosei General Hospital (Japan)

    1999-06-01

    We evaluated the detection of gastric varices, inflowing blood vessels to gastric varices, and outflowing blood vessels from gastric varices via magnetic resonance (MR) angiography in 31 patients with gastric varices. Twenty-four patients had F{sub 2} type varices and 7 had F{sub 3} type, classified according to the Japanese Research Society for Portal Hypertension. Seventeen patients had cardiofornical varices, and 14 had fundal varices. All patients were examined with an MR system operating at 1.5 T. MR angiography was performed using the two-dimensional time-of-flight method. With MR angiography, the imaging of gastric varices was clearly delineated in 28 of the 31 patients (90.3%). From the images of MR angiography, flow direction itself cannot be determined. The outflowing blood vessels of gastric varices were reported to be the gastro-renal shunt and the subphrenic vein, and angiographic findings have shown the inflowing blood vessels to be the left gastric vein (LGV), the short gastric vein (SGV), and the posterior gastric vein (PGV). In 25 of the 31 patients (80.7%), the outflowing blood vessels from gastric varices were detected (gastro-renal shunt in 24; subphrenic vein in 1). MR angiography provided clear images of the inflowing blood vessels to gastric varices in 18 of the 31 patients (58.1%). These inflowing vessels were categorized as SGV in 7 patients, LGV in 5, LGV and SGV in 4, and LGV and PGV in 2. We suggest that MR angiography be used as a routine method for detecting and diagnosing collateral veins in patients with gastric varices. (author)

  3. Control of Transport-barrier relaxations by Resonant Magnetic Perturbations

    CERN Document Server

    Leconte, M; Garbet, X; Benkadda, S

    2009-01-01

    Transport-barrier relaxation oscillations in the presence of resonant magnetic perturbations are investigated using three-dimensional global fluid turbulence simulations from first principles at the edge of a tokamak. It is shown that resonant magnetic perturbations have a stabilizing effect on these relaxation oscillations and that this effect is due mainly to a modification of the pressure profile linked to the presence of both residual residual magnetic island chains and a stochastic layer.

  4. Quantifying mixing using magnetic resonance imaging.

    Science.gov (United States)

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-25

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  5. Magnetic Field Gradient Waveform Monitoring for Magnetic Resonance

    Science.gov (United States)

    Han, Hui

    Linear magnetic field gradients have played a central role in Magnetic Resonance Imaging (MRI) since Fourier Transform MRI was proposed three decades ago. Their primary function is to encode spatial information into MR signals. Magnetic field gradients are also used to sensitize the image contrast to coherent and/or incoherent motion, to selectively enhance an MR signal, and to minimize image artifacts. Modern MR imaging techniques increasingly rely on the implementation of complex gradient waveforms for the manipulation of spin dynamics. However, gradient system infidelities caused by eddy currents, gradient amplifier imperfections and group delays, often result in image artifacts and other errors (e.g., phase and intensity errors). This remains a critical problem for a wide range of MRI techniques on modern commercial systems, but is of particular concern for advanced MRI pulse sequences. Measuring the real magnetic field gradients, i.e., characterizing eddy currents, is critical to addressing and remedying this problem. Gradient measurement and eddy current calibration are therefore a general topic of importance to the science of MRI. The Magnetic Field Gradient Monitor (MFGM) idea was proposed and developed specifically to meet these challenges. The MFGM method is the heart of this thesis. MFGM methods permit a variety of magnetic field gradient problems to be investigated and systematically remedied. Eddy current effects associated with MR compatible metallic pressure vessels were analyzed, simulated, measured and corrected. The appropriate correction of eddy currents may enable most MR/MRI applications with metallic pressure vessels. Quantitative imaging (1D/2D) with model pressure vessels was successfully achieved by combining image reconstruction with MFGM determined gradient waveform behaviour. Other categories of MR applications with metallic vessels, including diffusion measurement and spin echo SPI T2 mapping, cannot be realized solely by MFGM guided

  6. Non-resonant magnetic braking on JET and TEXTOR

    DEFF Research Database (Denmark)

    Sun, Y.; Liang, Y.; Shaing, K.C.

    2012-01-01

    The non-resonant magnetic braking effect induced by a non-axisymmetric magnetic perturbation is investigated on JET and TEXTOR. The collisionality dependence of the torque induced by the n = 1, where n is the toroidal mode number, magnetic perturbation generated by the error field correction coil...

  7. Magnetic resonance urography for diagnosis of pediatric ureteral stricture.

    Science.gov (United States)

    Arlen, Angela M; Kirsch, Andrew J; Cuda, Scott P; Little, Stephen B; Jones, Richard A; Grattan-Smith, J Damien; Cerwinka, Wolfgang H

    2014-10-01

    Ureteral stricture is a rare cause of hydronephrosis in children and is often misdiagnosed on ultrasound (US) and diuretic renal scintigraphy (DRS), requiring intraoperative diagnosis. We evaluated ureteral strictures diagnosed by magnetic resonance urography (MRU) at our institution. Children with ureteral stricture who underwent MRU were identified. Patient demographics, prior imaging, MRU findings, and management were assessed. The efficacy of MRU in diagnosis of stricture was compared with US and DRS. Patients with ureteropelvic or ureterovesical junction obstruction were excluded. Twenty-eight ureteral strictures diagnosed by MRU between 2003 and 2013 were identified; 22% of strictures were diagnosed by DRS ± US. The mean age at MRU diagnosis was 2.4 years (range 4 weeks-15 years). Hydronephrosis was the most common presentation, accounting for 20 (71%) cases. Other etiologies included pain (3), incontinence (2), and urinary tract infection, cystic kidney, and absent kidney, present in one case each. A mean of 2.7 imaging studies was obtained prior to MRU diagnosis. Twenty-one (75%) ureteral strictures required surgical intervention, with the approach dependent upon location. MRU provides excellent anatomic and functional detail of the collecting system, leading to accurate diagnosis and management of ureteral stricture in children. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  8. Unexpected Findings in Magnetic Resonance Enterography and Their Clinical Significance

    Directory of Open Access Journals (Sweden)

    Srivathsan Ravindran

    2016-01-01

    Full Text Available Aims. To identify the prevalence of colonic and extraenteric incidental findings in magnetic resonance enterography (MRE and their clinical significance. Methods. We retrospectively analysed 470 MRE studies carried out between March 2012 and 2014. Incidental findings were defined as those not expected from or made apparent on the referral. MRE reports were reviewed for colonic and extraenteric findings, subcategorised into “clinically significant” and “insignificant.” Follow-up was identified from the electronic patient record. Results. The majority of MRE requests were made for inflammatory bowel disease (97%. In total, 114 incidental findings were noted in 94 (20% scans performed. There were 29 “colonic” findings (25% with 55% having a diagnosis of colitis. Out of 85 extraenteric findings, ovarian cysts (25%, renal cysts (10%, and abdominal lymphadenopathy (9% were the commonest. Cumulatively, 59 cases were clinically significant (52%; of these, 30 findings were not previously diagnosed, amounting to 26% of all incidental findings. This led to intervention in seven patients. Conclusions. Incidental findings are common in MRE and there is a substantial proportion that is clinically significant and requires further investigation. There need to be stratification of risk and employment of local guidelines in order to achieve this.

  9. Tuning Coler Magnetic Current Apparatus with Magneto-Acoustic Resonance

    Science.gov (United States)

    Ludwig, Thorsten

    An attempt was made to tune the Coler magnetic current apparatus with the magneto acoustic resonance of the magnetic rods. Measurements with a replica of the famous Coler "Magnetstromapparat" were conducted. In order to tune the acoustic, magnetic and electric resonance circuits of the Coler device the magneto-acoustic resonance was measured with a frequency scan through a function generator and a lock-in amplifier. The frequency generator was powering a driving coil, while the lock-in was connected to a pickup coil. Both coils were placed on a magnetic rod. Resonances were observed up to the 17th harmonic. The quality Q of the observed resonances was 270. To study the magneto-acoustic resonance in the time domain a pair of Permendur rods were employed. The magneto-acoustic resonances of the Permendur rods were observed with an oscilloscope. Spectra of the magneto acoustic resonance were measured for the Permendur rods and for a Coler replica magnet in the frequency range from 25 kHz to 380 kHz. The next step was to bring the resonances of the Permendur rods close together so that they overlap. The 10thharmonic was chosen because it was close to the 180 kHz that Hans Coler related to ferromagnetism. Further more magneto-acoustic coupling between the Permendur rods was studied. Finally the question was explored if Hans Coler converted vacuum fluctuations via magnetic and acoustic resonance into electricity. There is a strong connection between magnetism and quantum field zero point energy (ZPE). An outlook is given on next steps in the experiments to unveil the working mechanism of the Coler magnetic current apparatus.

  10. Purcell factor of Mie resonators featuring electric and magnetic modes

    CERN Document Server

    Zambrana-Puyalto, Xavier

    2015-01-01

    We present a modal approach to compute the Purcell factor in Mie resonators exhibiting both electric and magnetic resonances. The analytic expressions of the normal modes are used to calculate the effective volumes. We show that important features of the effective volume can be predicted thanks to the translation-addition coefficients of a displaced dipole. Using our formalism, it is easy to see that, in general, the Purcell factor of Mie resonators is not dominated by a single mode, but rather by a large superposition. Finally we consider a silicon resonator homogeneously doped with electric dipolar emitters, and we show that the average electric Purcell factor dominates over the magnetic one.

  11. Real-time magnetic resonance imaging investigation of resonance tuning in soprano singing

    OpenAIRE

    Bresch, Erik; Narayanan, Shrikanth

    2010-01-01

    This article investigates using real-time magnetic resonance imaging the vocal tract shaping of 5 soprano singers during the production of two-octave scales of sung vowels. A systematic shift of the first vocal tract resonance frequency with respect to the fundamental is shown to exist for high vowels across all subjects. No consistent systematic effect on the vocal tract resonance could be shown across all of the subjects for other vowels or for the second vocal tract resonance.

  12. Magnetic resonance perfusion imaging without contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz [University Hospital of Tuebingen, Section on Experimental Radiology, Tuebingen (Germany); Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D. [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-08-15

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  13. Magnetic Resonance Imaging in Pediatric Elbow Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Pudas, T.; Hurme, T.; Mattila, K.; Svedstroem, E. [Univ. of Turku, (Finland). Depts. of Radiology and Pediatric Surgery

    2005-10-01

    Purpose: Magnetic resonance imaging (MRI) evaluation of pediatric elbow trauma with or without a visible fracture on radiography. Material and Methods: MRI was performed in the acute phase in 25 children with an elbow injury. Nine patients with an elbow effusion only on radiographs and 16 with a fracture or luxation seen on radiographs underwent subsequent MRI. No sedation was used. Results: MRI revealed eight occult fractures (89%) in seven out of nine patients who had only an effusion on radiographs. Based on MRI findings, septic arthritis was suspected in one patient. Two patients out of five with a supracondylar fracture on the radiograph had a cartilage lesion in the humerus. MRI depicted a 3-mm gap on the articular surface in two patients with a lateral condyle fracture, a more accurate fracture location in two patients than the radiographs, and an additional occult fracture in two patients. MRI showed a fracture not seen on radiographs in two of three patients with prior luxation. Conclusion: MRI is a sensitive and accurate method in the diagnosis of pediatric elbow injuries, especially when only an effusion is present on radiographs. Occult fractures are more common in pediatric patients with elbow injury than reported earlier.

  14. Magnetic resonance imaging in complex partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Furune, Sunao; Negoro, Tamiko; Maehara, Mitsuo; Nomura, Kazushi; Miura, Kiyokuni; Takahashi, Izumi; Watanabe, Kazuyoshi (Nagoya Univ. (Japan). Faculty of Medicine)

    1989-09-01

    Magnetic resonance imaging (MRI) and computed tomography (CT) were performed on 45 patients with intractable complex partial seizures. MRI was performed with a superconducting whole-body scanner operating at 0.5 tesla (T) and 1.5 T. In patients with temporal lobe epilepsy, 8 of 24 patients had abnormal CT, but 16 or 24 patients showed abnormal MRI. 1.5 T MRI detected more abnormality than 0.5 T MRI when CT was normal. In patients with frontal lobe epilepsy, 5 of 7 patients had normal CT and MRI. In 2 other patients, MRI demonstrated an arachnoid cyst and increased signal intensity area on the T2-weighted images which were not detected by CT. In patients with occipital lobe epilepsy, 5 of 6 patients show abnormal CT and MRI. In patients with tuberous sclerosis, MRI revealed some increased signal intensity areas on the T2-weighted images in the occipital and temporal lobe, which were not detected by CT. Most surface EEG foci corresponded with the side of MRI abnormality. These data indicate that MRI is more informative than CT in complex partial seizures. MRI is the imaging technique of choice in the diagnosis of complex partial seizures. (author).

  15. Focal liver lesions: Practical magnetic resonance imagingapproach

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    With the widespread of cross-sectional imaging, a growthof incidentally detected focal liver lesions (FLL) hasbeen observed. A reliable detection and characterizationof FLL is critical for optimal patient management.Maximizing accuracy of imaging in the context ofFLL is paramount in avoiding unnecessary biopsies,which may result in post-procedural complications. Atremendous development of new imaging techniqueshas taken place during these last years. Nowadays,Magnetic resonance imaging (MRI) plays a key rolein management of liver lesions, using a radiation-freetechnique and a safe contrast agent profile. MRI playsa key role in the non-invasive correct characterizationof FLL. MRI is capable of providing comprehensiveand highly accurate diagnostic information, withthe additional advantage of lack of harmful ionizingradiation. These properties make MRI the mainstay forthe noninvasive evaluation of focal liver lesions. In thispaper we review the state-of-the-art MRI liver protocol,briefly discussing different sequence types, the uniquecharacteristics of imaging non-cooperative patients anddiscuss the role of hepatocyte-specific contrast agents.A review of the imaging features of the most commonbenign and malignant FLL is presented, supplementedby a schematic representation of a simplistic practicalapproach on MRI.

  16. Endorectal magnetic resonance imaging in persistent hemospermia

    Directory of Open Access Journals (Sweden)

    Adilson Prando

    2008-03-01

    Full Text Available OBJECTIVE: To present the spectrum of abnormalities found at endorectal magnetic resonance imaging (E-MRI, in patients with persistent hemospermia. MATERIALS AND METHODS: A review of E-MRI findings observed in 86 patients with persistent hemospermia was performed and results compared with those reported in the literature. Follow-up was possible in 37 of 86 (43% patients with hemospermia. RESULTS: E-MRI showed abnormal findings in 52 of 86 (60% patients with hemospermia. These findings were: a hemorrhagic seminal vesicle and ejaculatory duct, isolated (n = 11 or 21% or associated with complicated midline prostatic cyst (n = 10 or 19.0%; b hemorrhagic chronic seminal vesiculitis, isolated (n = 14 or 27% or associated with calculi within dilated ejaculatory ducts (n = 2 or 4 %; c hemorrhagic seminal vesicle associated with calculi within dilated ejaculatory duct (n = 4 or 7.7% or within seminal vesicle (n = 4 or 7.7%; d non-complicated midline prostatic cyst (n = 6 or 11.5%; and e prostate cancer (n = 1 or 2%. Successful treatment was more frequent in patients with chronic inflammatory and/or obstructive abnormalities. CONCLUSION: E-MRI should be considered the modality of choice, for the evaluation of patients with persistent hemospermia.

  17. Endorectal magnetic resonance imaging in persistent hemospermia

    Energy Technology Data Exchange (ETDEWEB)

    Prando, Adilson [Vera Cruz Hospital, Campinas, SP (Brazil). Dept. of Radiology and Diagnostic Imaging

    2008-03-15

    Objective: To present the spectrum of abnormalities found at endorectal magnetic resonance imaging (E-MRI), in patients with persistent hemospermia. Materials and methods: A review of E-MRI findings observed in 86 patients with persistent hemospermia was performed and results compared with those reported in the literature. Follow-up was possible in 37 of 86 (43%) patients with hemospermia. Results: E-MRI showed abnormal findings in 52 of 86 (60%) patients with hemospermia. These findings were: a) hemorrhagic seminal vesicle and ejaculatory duct, isolated (n = 11 or 21%) or associated with complicated midline prostatic cyst (n = 10 or 19.0%); b) hemorrhagic chronic seminal vesiculitis, isolated (n = 14 or 27%) or associated with calculi within dilated ejaculatory ducts (n = 2 or 4 %); c) hemorrhagic seminal vesicle associated with calculi within dilated ejaculatory duct (n = 4 or 7.7%) or within seminal vesicle (n = 4 or 7.7%); d) non-complicated midline prostatic cyst (n = 6 or 11.5%); and e) prostate cancer (n = 1 or 2%). Successful treatment was more frequent in patients with chronic inflammatory and/or obstructive abnormalities. Conclusion: E-MRI should be considered the modality of choice, for the evaluation of patients with persistent hemospermia. (author)

  18. Magnetic resonance imaging of the normal placenta.

    Science.gov (United States)

    Blaicher, Wibke; Brugger, Peter C; Mittermayer, Christoph; Schwindt, Jens; Deutinger, Josef; Bernaschek, Gerhard; Prayer, Daniela

    2006-02-01

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  19. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  20. Pancreatitis: computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P.J.A.; Sheridan, M.B. [Dept. of Clinical Radiology, St. James' s University Hospital, Leeds (United Kingdom)

    2000-03-01

    The value of CT in management of severe acute pancreatitis is well established. Some, but not all, experimental studies suggest a detrimental effect of intravenous iodinated contrast agents in acute pancreatitis, but although initial clinical data tends to support this, the positive advantages of enhanced CT outweigh the possible risks. Magnetic resonance imaging has been shown to be as effective as CT in demonstrating the presence and extent of pancreatic necrosis and fluid collections, and probably superior in indicating the suitability of such collections for percutaneous drainage. Image-guided intervention remains a key approach in the management of severely ill patients, and the indications, techniques and results of radiological intervention are reviewed herein. Both CT and MRI can be used to diagnose advanced chronic pancreatitis, with the recent addition of MRCP as a viable alternative to diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Both MRCP and CT/MR imaging of the pancreatic parenchyma still have limitations in the recognition of the earliest changes of chronic pancreatitis - for which ERCP and tests of pancreatic function remain more sensitive - but the clinical significance of these minor changes remains contentious. (orig.)

  1. Potts disease: Diagnosis with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pursey, Jacqueline [MRI Department, Gartnavel General Hospitial, 1053 Great Western road, Glasgow G12 0YN (United Kingdom)], E-mail: Jacqueline.pursey@ggc.scot.nhs.uk; Stewart, Sharon [School of Health and Social Care, Caledonian University, Glasgow (United Kingdom)

    2010-02-15

    The eponymously named Potts disease is a relatively rare form of Tuberculosis (TB) which affects the spine. TB of the spine is one of the earliest diseases known to man and in the 20th century was thought to be a disease which had been defeated by the advent of antitubercular drugs. Over the last two decades there have been several reports which indicate a revival of TB in both the developing and developed world. Factors which may be contributing to this are the spread of the HIV virus, increased immigration and the emergence of drug resistant strains of the TB bacteria. Potts disease has an insidious onset and often the radiographic findings are far advanced when a diagnosis is finally reached. MRI is able to detect changes to the vertebrae in Potts disease earlier than radiographs. This case report outlines the clinical presentation of a young male with Potts disease who was HIV negative, and the important role that MRI plays in diagnosis and therefore in appropriate and timely intervention. The typical magnetic resonance (MR) imaging features and the radiographic hallmarks of the disease will also be discussed.

  2. Magnetic resonance imaging of cystic periventricular leukomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Kadoi, Nobuaki; Nomura, Junko; Nowatari, Masahiko; Ohta, Takeo; Kamohara, Takashi; Yashiro, Kimio (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1990-08-01

    A study was performed to assess the values of magnetic resonance (MR) imaging in evaluation and the follow up of patients with cystic periventricular leukomalacia. Ten patients selected for MR imaging were diagnosed as having periventricular cystic lesions based on US scans. The range of gestational ages was 27 to 32 weeks, and the range of birth weights was 927 to 2,046 g. Twenty MR examinations were carried out using a 0.5 T superconducting system (Resona; Yokogawa). On the first MR examinations, taken by 6 months of age, low signal intensity lesions within the periventricular white matter, moderate ventriculomegaly with irregularity of the ventricular wall and delayed myelination were observed. These were the MR findings observed in the subacute stage of PVL. On the second or the third MR examinations, taken after 12 months of age, increased signal intensity in periventricular white matter on T{sub 2} weighted images decreased volume of periventricular white matter and centrum semiovale and the ventriculomagaly with irregularity of ventricular wall were observed. However, progressions of myelination were proved to be not delayed in comparison with age matched controls. These were thought to be the MR findings of late stage of PVL. As the US findings of PVL have good correlation with pathologic changes revealed at autopsy, MR imaging can depict myelination and detect PVL lesion beyond the neonatal period. These observations demonstrate the value of the MR imaging for the follow up of the patients with PVL beyond the time of fontanel closure. (author).

  3. Statistical normalization techniques for magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Russell T. Shinohara

    2014-01-01

    Full Text Available While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.

  4. Magnetic resonance imaging in retropharyngeal tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Ekbon, K.; Annell, K.; Traeff, J.; Torhall, J. (Soeder Hospital, Stockholm (Sweden))

    1994-08-01

    Seven consecutive patients with acute retropharyngeal tendinitis underwent plain X-ray and magnetic resonance imaging (MRI) of the cervical spine. All seven had marked soft tissue swelling anterior to C1 and C2 on plain X-ray, and soft tissue calcification at this level was present in five of them. On MRI, there was markedly increased signal intensity on T[sub 2]-weighted images in the acute phase and intermediate signal intensity on T[sub 1]-weighted images, anterior to the level of CI and C2, often extending as far down as C6. These changes correlated well with the soft tissue swelling seen on conventional X-ray of the cervical spine. The maximum mid-sagittal thickness of the soft issues was significantly greater in the tendinitis patients than in 12 control subjects free of symptoms from the pharynx or the cervical spine. Treatment with non-steroidal anti-inflammatory drugs rapidly alleviated symptoms, and at follow-up MRI showed regression or complete restitution of the changes. In conclusion, MRI can visualize the edematous changes in the longus colli muscle and adds useful diagnostic information in suspected cases of acute retropharyngeal tendinitis. 9 refs., 4 figs., 3 tabs.

  5. Compression-sensitive magnetic resonance elastography

    Science.gov (United States)

    Hirsch, Sebastian; Beyer, Frauke; Guo, Jing; Papazoglou, Sebastian; Tzschaetzsch, Heiko; Braun, Juergen; Sack, Ingolf

    2013-08-01

    Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus.

  6. Magnetic resonance angiography in suspected cerebral vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido [Department of Radiology, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Maes, Frederik [Department of Medical Imaging Computing, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Velghe, Beatrijs [Department of Radiology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600, Genk (Belgium)

    2004-06-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  7. Meralgia paresthetica: 3-Tesla magnetic resonance neurography.

    Science.gov (United States)

    Chhabra, Avneesh; Del Grande, Filippo; Soldatos, Theodoros; Chalian, Majid; Belzberg, Allan J; Williams, Eric H; Jalali, Farahani S; Thawait, Gaurav K; Eng, John; Carrino, John A

    2013-06-01

    To assess the diagnostic accuracy and observer performance of 3-Tesla magnetic resonance neurography (MRN) in the evaluation of meralgia paresthetica (MP). Two independent readers were blinded to the clinical diagnosis and evaluated the MRN studies of the pelvis of 11 patients with MP and 28 control participants. In each study, the lateral femoral cutaneous nerves were assessed for signal alteration and/or neuroma formation, indicating lateral femoral cutaneous neuropathy, at various levels along their course. Intra- and inter-observer reliability was evaluated. Both readers exhibited substantial intraobserver agreement in detecting signal alterations and neuroma formation of the lateral femoral cutaneous nerve (LFCN). The readers demonstrated moderate interobserver agreement in detecting signal alteration of the LFCN and poor interobserver agreement in diagnosing neuroma formation. Sensitivity, specificity, positive predictive value, and negative predictive value of LFCN neuropathy diagnosis were ≥ 71 % and ≥ 94 % for both readers respectively. The diagnostic test accuracy was ≥ 90 % for both readers. 3-Tesla MRN provides reliable and accurate diagnostic evaluation of meralgia paresthetica.

  8. Neural network segmentation of magnetic resonance images

    Science.gov (United States)

    Frederick, Blaise

    1990-07-01

    Neural networks are well adapted to the task of grouping input patterns into subsets which share some similarity. Moreover once trained they can generalize their classification rules to classify new data sets. Sets of pixel intensities from magnetic resonance (MR) images provide a natural input to a neural network by varying imaging parameters MR images can reflect various independent physical parameters of tissues in their pixel intensities. A neural net can then be trained to classify physically similar tissue types based on sets of pixel intensities resulting from different imaging studies on the same subject. A neural network classifier for image segmentation was implemented on a Sun 4/60 and was tested on the task of classifying tissues of canine head MR images. Four images of a transaxial slice with different imaging sequences were taken as input to the network (three spin-echo images and an inversion recovery image). The training set consisted of 691 representative samples of gray matter white matter cerebrospinal fluid bone and muscle preclassified by a neuroscientist. The network was trained using a fast backpropagation algorithm to derive the decision criteria to classify any location in the image by its pixel intensities and the image was subsequently segmented by the classifier. The classifier''s performance was evaluated as a function of network size number of network layers and length of training. A single layer neural network performed quite well at

  9. Antepartum pelvimetry by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Koshiba, Hisato; Kikuchi, Noriko; Ogino, Yoshio [Kyoto Second Red Cross Hospital (Japan)] (and others)

    2001-09-01

    Evaluation of the pelvis by pelvimetry plays an important role in selecting patients for possible vaginal delivery. However, x-ray pelvimetry involves the disadvantage of fetal exposure to ionizing radiation. The clear advantage of magnetic resonance imaging (MRI) pelvimetry is that this procedure is free from ionizing radiation. Measurements with MRI are as reliable as those with x-ray pelvimetry and the contrast of MRI is even better. MRI shows soft-tissue structures as well as bone. The use of this scanning technique is contraindicated for patients with pacemakers. But, pacemakers are rarely encountered in young pregnant women. In our department, 203 patients underwent antepartum pelvimetry with MRI during the last 5 years. T1-weighted mediosagittal images were used for measurement of the obstetric conjugate (OC) and to determine whether a straight sacrum can be recognized. Data were compared between patients who had undergone cesarean section due to cephalopelvic disproportion (CPD) and patients who experienced vaginal delivery. OC and OC-biparietal diameter were significantly different between the two groups. MRI can be further used for the diagnosis of CPD and to select patients for whom planned vaginal delivery is appropriate. (author)

  10. Cardiovascular magnetic resonance in pericardial diseases

    Directory of Open Access Journals (Sweden)

    Francone Marco

    2009-05-01

    Full Text Available Abstract The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases.

  11. Constraining groundwater modeling with magnetic resonance soundings.

    Science.gov (United States)

    Boucher, Marie; Favreau, Guillaume; Nazoumou, Yahaya; Cappelaere, Bernard; Massuel, Sylvain; Legchenko, Anatoly

    2012-01-01

    Magnetic resonance sounding (MRS) is a noninvasive geophysical method that allows estimating the free water content and transmissivity of aquifers. In this article, the ability of MRS to improve the reliability of a numerical groundwater model is assessed. Thirty-five sites were investigated by MRS over a ∼5000 km(2) domain of the sedimentary Continental Terminal aquifer in SW Niger. Time domain electromagnetic soundings were jointly carried out to estimate the aquifer thickness. A groundwater model was previously built for this section of the aquifer and forced by the outputs from a distributed surface hydrology model, to simulate the observed long-term (1992 to 2003) rise in the water table. Uncertainty analysis had shown that independent estimates of the free water content and transmissivity values of the aquifer would facilitate cross-evaluation of the surface-water and groundwater models. MRS results indicate ranges for permeability (K = 1 × 10(-5) to 3 × 10(-4) m/s) and for free water content (w = 5% to 23% m(3) /m(3) ) narrowed by two orders of magnitude (K) and by ∼50% (w), respectively, compared to the ranges of permeability and specific yield values previously considered. These shorter parameter ranges result in a reduction in the model's equifinality (whereby multiple combinations of model's parameters are able to represent the same observed piezometric levels), allowing a better constrained estimate to be derived for net aquifer recharge (∼22 mm/year).

  12. Magnetic resonance imaging of pelvic endometriosis.

    Science.gov (United States)

    Méndez Fernández, R; Barrera Ortega, J

    Endometriosis is common in women of reproductive age; it can cause pelvic pain and infertility. It is important to diagnose endometriosis and to thoroughly evaluate its extension, especially when surgical treatment is being considered. Magnetic resonance imaging (MRI) with careful examination technique and interpretation enables more accurate and complete diagnosis and staging than ultrasonography, especially in cases of deep pelvic endometriosis. Furthermore, MRI can identify implants in sites that can be difficult to access in endoscopic or laparoscopic explorations. In this article, we describe the appropriate MRI protocol for the study of pelvic endometriosis and the MRI signs of pelvic organ involvement. It is necessary to know the subtle findings and to look for them so we can ensure that they are not overlooked. We describe clinical grading systems for endometriosis and review the diagnostic efficacy of MRI in comparison with other imaging techniques and surgery. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Magnetic resonance imaging (MRI) in parasinus mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Kakisu, Yonetsugu; Watanabe, Yoshihiro (Chiba Univ. (Japan). School of Medicine)

    1989-07-01

    We evaluated the clinical value of magnetic resonance imaging (MRI) in 9 cases of parasinus mucocele. The series included frontal mucocele 1 case, frontal and anterior ethmoidal mucocele 3 cases, anterior mucocele 2 cases, posterior ethmoidal mucocele 2 cases, and maxillary mucocele 1 case. MRI was performed with proton density P (300), inversion recovery IR (1000, 350), and spin echo SE (1000, 60/90) with 0.1 tesla resistive conducting system, or with T/sub 1/-weighted SE (440, 40), IR (1500, 500) and T/sub 2/-weighted SE (1500, 500) with 0.5 tesla superconducting system. We obtained images of variable intensities when employing P, IR and T/sub 1/-weighted SE imaging. It was possible to differentiate mucocele from normal orbital tissue by comparison with T/sub 2/-weighted imaging. All the 9 cases manifested a high intensity of T/sub 2/-weighted images. The findings were suggestive of a possibility to verify the content to parasinus cysts by MRI findings. (author).

  14. Magnetic resonance tomography of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas [University Hospital, University of Berne, Department of Interventional, Pediatric and Diagnostic Radiology Inselspital, Berne (Switzerland); Endel, Gottfried [Main Association of Austrian Social Insurance Institutions, Vienna (Austria)

    2015-10-15

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  15. NUCLEAR MAGNETIC RESONANCE STUDIES OF URANOCENES

    Energy Technology Data Exchange (ETDEWEB)

    Luke, Wayne D.; Streitwieser, Jr., Andrew

    1979-12-01

    In the past several years a substantial amount of work has been devoted toward evaluation of the contact and pseudocontact contributions to the observed isotropic shifts in H nuclear magnetic resonance (NMR) spectra of uranium(IV) organometallic compounds. One reason for interest in this area arises from using the presence of contact shifts as a prcbe for covalent character in the uranium carbon bonds in these compounds. Several extensive {sup 1}H NNR studies on Cp{sub 3} U-X compounds and less extensive studies on uranocenes have been reported. Interpretation of these results suggests that contact shifts-contribute significantly to the observed isotropic shifts. Their presence has been taken as indicative of covalent character of metal carbon bonds in these systems, but agreement is not complete. In this paper we shall review critically the work reported on uranocenes in the light of recent results and report recent work on attempted separation of the observed isotropic shifts in alkyluranocenes into contact and pseudocontact components.

  16. Magnetic resonance imaging of cerebellopontine angle lesions

    Directory of Open Access Journals (Sweden)

    Pratiksha Yadav

    2015-01-01

    Full Text Available Background: Cerebellopontine angle (CPA tumors are usually benign, and they are divided into extra-axial, intra-axial, extradural, and petrous axis tumors. CPA pathologies can be asymptomatic or it may present with vertigo, tinnitus, or unilateral hearing loss depending upon the site of tumor origin and displacement of the neurovascular structure. Aim and Objectives: To evaluate the role of magnetic resonance imaging (MRI aided with contrast-enhanced MRI as an imaging modality for diagnosis of CPA lesions. Materials and Methods: Analysis of 36 patients of CPA lesions over a period of 2 years was done. MRI was performed on Siemens 1.5 Tesla MAGNETOM Avanto Machine. Conclusion: There are spectrums of pathologies, which can present with these symptoms, which includes tumors, vascular malformations, and vascular loop compressing vestibulocochlear nerve or mastoid pathology so it is important to investigate the patient by MRI. Contrast-enhanced MRI is the most sensitive investigation in the evaluation of the CPA lesions, its characteristic, and its extent.

  17. Magnetic resonance imaging in glenohumeral instability

    Science.gov (United States)

    Jana, Manisha; Gamanagatti, Shivanand

    2011-01-01

    The glenohumeral joint is the most commonly dislocated joint of the body and anterior instability is the most common type of shoulder instability. Magnetic resonance (MR) imaging, and more recently, MR arthrography, have become the essential investigation modalities of glenohumeral instability, especially for pre-procedure evaluation before arthroscopic surgery. Injuries associated with glenohumeral instability are variable, and can involve the bones, the labor-ligamentous components, or the rotator cuff. Anterior instability is associated with injuries of the anterior labrum and the anterior band of the inferior glenohumeral ligament, in the form of Bankart lesion and its variants; whereas posterior instability is associated with reverse Bankart and reverse Hill-Sachs lesion. Multidirectional instability often has no labral pathology on imaging but shows specific osseous changes such as increased chondrolabral retroversion. This article reviews the relevant anatomy in brief, the MR imaging technique and the arthrographic technique, and describes the MR findings in each type of instability as well as common imaging pitfalls. PMID:22007285

  18. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    Energy Technology Data Exchange (ETDEWEB)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee [Chungnam National University College of Medicine, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2013-03-15

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  19. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  20. Segmentation of neuroanatomy in magnetic resonance images

    Science.gov (United States)

    Simmons, Andrew; Arridge, Simon R.; Barker, G. J.; Tofts, Paul S.

    1992-06-01

    Segmentation in neurological magnetic resonance imaging (MRI) is necessary for feature extraction, volume measurement and for the three-dimensional display of neuroanatomy. Automated and semi-automated methods offer considerable advantages over manual methods because of their lack of subjectivity, their data reduction capabilities, and the time savings they give. We have used dual echo multi-slice spin-echo data sets which take advantage of the intrinsically multispectral nature of MRI. As a pre-processing step, a rf non-uniformity correction is applied and if the data is noisy the images are smoothed using a non-isotropic blurring method. Edge-based processing is used to identify the skin (the major outer contour) and the eyes. Edge-focusing has been used to significantly simplify edge images and thus allow simple postprocessing to pick out the brain contour in each slice of the data set. Edge- focusing is a technique which locates significant edges using a high degree of smoothing at a coarse level and tracks these edges to a fine level where the edges can be determined with high positional accuracy. Both 2-D and 3-D edge-detection methods have been compared. Once isolated, the brain is further processed to identify CSF, and, depending upon the MR pulse sequence used, the brain itself may be sub-divided into gray matter and white matter using semi-automatic contrast enhancement and clustering methods.

  1. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  2. Magnetic resonance imaging at ultrahigh fields.

    Science.gov (United States)

    Ugurbil, Kamil

    2014-05-01

    Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques.

  3. Science Drivers and Technical Challenges for Advanced Magnetic Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Karl T.; Pruski, Marek; Washton, Nancy M.; Lipton, Andrew S.

    2013-03-07

    This report recaps the "Science Drivers and Technical Challenges for Advanced Magnetic Resonance" workshop, held in late 2011. This exploratory workshop's goal was to discuss and address challenges for the next generation of magnetic resonance experimentation. During the workshop, participants from throughout the world outlined the science drivers and instrumentation demands for high-field dynamic nuclear polarization (DNP) and associated magnetic resonance techniques, discussed barriers to their advancement, and deliberated the path forward for significant and impactful advances in the field.

  4. Correlation of Magnetic Resonance Imaging Tumor Volume with Histopathology

    Science.gov (United States)

    Turkbey, Baris; Mani, Haresh; Aras, Omer; Rastinehad, Ardeshir R.; Shah, Vijay; Bernardo, Marcelino; Pohida, Thomas; Daar, Dagane; Benjamin, Compton; McKinney, Yolanda L.; Linehan, W. Marston; Wood, Bradford J.; Merino, Maria J.; Choyke, Peter L.; Pinto, Peter A.

    2017-01-01

    Purpose The biology of prostate cancer may be influenced by the index lesion. The definition of index lesion volume is important for appropriate decision making, especially for image guided focal treatment. We determined the accuracy of magnetic resonance imaging for determining index tumor volume compared with volumes derived from histopathology. Materials and Methods We evaluated 135 patients (mean age 59.3 years) with a mean prostate specific antigen of 6.74 ng/dl who underwent multiparametric 3T endorectal coil magnetic resonance imaging of the prostate and subsequent radical prostatectomy. Index tumor volume was determined prospectively and independently by magnetic resonance imaging and histopathology. The ellipsoid formula was applied to determine histopathology tumor volume, whereas manual tumor segmentation was used to determine magnetic resonance tumor volume. Histopathology tumor volume was correlated with age and prostate specific antigen whereas magnetic resonance tumor volume involved Pearson correlation and linear regression methods. In addition, the predictive power of magnetic resonance tumor volume, prostate specific antigen and age for estimating histopathology tumor volume (greater than 0.5 cm3) was assessed by ROC analysis. The same analysis was also conducted for the 1.15 shrinkage factor corrected histopathology data set. Results There was a positive correlation between histopathology tumor volume and magnetic resonance tumor volume (Pearson coefficient 0.633, p <0.0001), but a weak correlation between prostate specific antigen and histopathology tumor volume (Pearson coefficient 0.237, p=0.003). On linear regression analysis histopathology tumor volume and magnetic resonance tumor volume were correlated (r2=0.401, p <0.00001). On ROC analysis AUC values for magnetic resonance tumor volume, prostate specific antigen and age in estimating tumors larger than 0.5 cm3 at histopathology were 0.949 (p <0.0000001), 0.685 (p=0.001) and 0.627 (p=0

  5. Anaesthesia for magnetic resonance imaging/computed tomography.

    Science.gov (United States)

    Funk, W; Taeger, K

    2000-08-01

    The need for general anaesthesia for magnetic resonance imaging/computed tomography investigations can be reduced by the implementation of structured sedation programmes supervised by anaesthetists. Despite its side-effects, chloral hydrate is still the drug most widely used. Rectal thiopental or intravenous propofol are suggested anaesthetic agents for pre-school children and uncooperative or claustrophobic individuals. Spiral computed tomography scans and ultrafast magnetic resonance imaging shorten immobilization times further. However, functional magnetic resonance imaging and intervention techniques in neuroradiology depend on a motionless patient. A useful strategy for testing anaesthesia equipment has been outlined.

  6. Advances in cardiac magnetic resonance imaging of congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Driessen, Mieke M.P. [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); The Interuniversity Cardiology Institute of the Netherlands (ICIN) - Netherlands Heart Institute, PO Box 19258, Utrecht (Netherlands); Breur, Johannes M.P.J. [Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands); Budde, Ricardo P.J.; Oorschot, Joep W.M. van; Leiner, Tim [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); Kimmenade, Roland R.J. van; Sieswerda, Gertjan Tj [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Meijboom, Folkert J. [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands)

    2015-01-01

    Due to advances in cardiac surgery, survival of patients with congenital heart disease has increased considerably during the past decades. Many of these patients require repeated cardiovascular magnetic resonance imaging to assess cardiac anatomy and function. In the past decade, technological advances have enabled faster and more robust cardiovascular magnetic resonance with improved image quality and spatial as well as temporal resolution. This review aims to provide an overview of advances in cardiovascular magnetic resonance hardware and acquisition techniques relevant to both pediatric and adult patients with congenital heart disease and discusses the techniques used to assess function, anatomy, flow and tissue characterization. (orig.)

  7. Resonant Raman Scattering from Silicon Nanoparticles Enhanced by Magnetic Response

    CERN Document Server

    Dmitriev, Pavel A; Milichko, Valentin A; Makarov, Sergey V; Mukhin, Ivan S; Samusev, Anton K; Krasnok, Alexander E; Belov, Pavel A; Kivshar, Yuri S

    2016-01-01

    Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions.

  8. Beam induced electron cloud resonances in dipole magnetic fields

    Science.gov (United States)

    Calvey, J. R.; Hartung, W.; Makita, J.; Venturini, M.

    2016-07-01

    The buildup of low energy electrons in an accelerator, known as electron cloud, can be severely detrimental to machine performance. Under certain beam conditions, the beam can become resonant with the cloud dynamics, accelerating the buildup of electrons. This paper will examine two such effects: multipacting resonances, in which the cloud development time is resonant with the bunch spacing, and cyclotron resonances, in which the cyclotron period of electrons in a magnetic field is a multiple of bunch spacing. Both resonances have been studied directly in dipole fields using retarding field analyzers installed in the Cornell Electron Storage Ring. These measurements are supported by both analytical models and computer simulations.

  9. Nuclear magnetic resonance data of C9H11ITe

    Science.gov (United States)

    Mikhova, B. M.

    This document is part of Part 6 `Organic Metalloid Compounds' of Subvolume D 'Chemical Shifts and Coupling Constants for Carbon-13' of Landolt-Börnstein III/35 'Nuclear Magnetic Resonance Data', Group III 'Condensed Matter'.

  10. Nuclear magnetic resonance data of C10H13ITe

    Science.gov (United States)

    Mikhova, B. M.

    This document is part of Part 6 `Organic Metalloid Compounds' of Subvolume D 'Chemical Shifts and Coupling Constants for Carbon-13' of Landolt-Börnstein III/35 'Nuclear Magnetic Resonance Data', Group III 'Condensed Matter'.

  11. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    DEFF Research Database (Denmark)

    de la Motte, Louise; Pedersen, Mads Møller; Thomsen, Carsten

    2013-01-01

    Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics...

  12. Magnetic resonance tomography for trauma of the cervical spine

    Energy Technology Data Exchange (ETDEWEB)

    Meydam, K.; Sehlen, S.; Schlenkhoff, D.; Kiricuta, J.C.; Beyer, H.K.

    1986-12-01

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed.

  13. Magnetic Resonance Fiber Tracking in a Neonate with Hemimegalencephaly

    OpenAIRE

    Re, Thomas J.; Scarciolla, Laura; Takahashi, Emi; Specchio, Nicola; Bernardi, Bruno De; Longo, Daniela

    2015-01-01

    A magnetic resonance diffusion fiber tracking study in neonate diagnosed with left hemisphere hemimegalencephaly is presented. Despite diffuse morphologic deformities identified in conventional imaging, all major pathways were identifiable bilaterally with minor aberrations in vicinity of morphologic lesions.

  14. Normal perinatal and paediatric postmortem magnetic resonance imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Child Health, London (United Kingdom); Barber, Joy L. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); Taylor, Andrew M. [Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London (United Kingdom); Sebire, Neil J. [UCL Institute of Child Health, London (United Kingdom); Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom)

    2015-04-01

    As postmortem imaging becomes more widely used following perinatal and paediatric deaths, the correct interpretation of images becomes imperative, particularly given the increased use of postmortem magnetic resonance imaging. Many pathological processes may have similar appearances in life and following death. A thorough knowledge of normal postmortem changes is therefore required within postmortem magnetic resonance imaging to ensure that these are not mistakenly interpreted as significant pathology. Similarly, some changes that are interpreted as pathological if they occur during life may be artefacts on postmortem magnetic resonance imaging that are of limited significance. This review serves to illustrate briefly those postmortem magnetic resonance imaging changes as part of the normal changes after death in fetuses and children, and highlight imaging findings that may confuse or mislead an observer to identifying pathology where none is present. (orig.)

  15. Nonlinear magnetization dynamics of antiferromagnetic spin resonance induced by intense terahertz magnetic field

    CERN Document Server

    Mukai, Y; Yamamoto, T; Kageyama, H; Tanaka, K

    2016-01-01

    We report on the nonlinear magnetization dynamics of a HoFeO3 crystal induced by a strong terahertz magnetic field resonantly enhanced with a split ring resonator and measured with magneto-optical Kerr effect microscopy. The terahertz magnetic field induces a large change (~40%) in the spontaneous magnetization. The frequency of the antiferromagnetic resonance decreases in proportion to the square of the magnetization change. A modified Landau-Lifshitz-Gilbert equation with a phenomenological nonlinear damping term quantitatively reproduced the nonlinear dynamics.

  16. Technical aspects of magnetic resonance imaging in parathyroid gland lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hemmingsson, A.; Ericsson, A.; Ljunghall, S.; Juhlin, C.; Jung, B.; Rastad, J.; Thuomas, K.A.; Akerstroem, G.

    Two patients with primary hyperparathyroidism were examined before parathyroid surgery with magnetic resonance imaging at 0.35 telsa in order to analyse optimal methods of visualization. Two large parathyroid glands in the neck had long transverse relaxation times which rendered them clearly visible in T2-weighted images as structures of a signal intensity higher than that of the surrounding. Large parathyroid lesions may thus be easily detected by magnetic resonance imaging provided proper examination parameters are employed.

  17. Nuclear magnetic resonance in environmental engineering: principles and applications.

    Science.gov (United States)

    Lens, P N; Hemminga, M A

    1998-01-01

    This paper gives an introduction to nuclear magnetic resonance spectroscopy (NMR) and magnetic resonance imaging (MRI) in relation to applications in the field of environmental science and engineering. The underlying principles of high resolution solution and solid state NMR, relaxation time measurements and imaging are presented. Then, the use of NMR is illustrated and reviewed in studies of biodegradation and biotransformation of soluble and solid organic matter, removal of nutrients and xenobiotics, fate of heavy metal ions, and transport processes in bioreactor systems.

  18. Implementation of Quantum Logic Gates by Nuclear Magnetic Resonance Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    DU Jiang-Feng; WU Ji-Hui; SHI Ming-Jun; HAN Liang; ZHOU Xian-Yi; YE Bang-Jiao; WENG Hui-Ming; HAN Rong-Dian

    2000-01-01

    Using nuclear magnetic resonance techniques with a solution of cytosine molecules, we show an implementation of certain quantum logic gates (including NOT gate, square-root of NOT gate and controlled-NOT gate), which have central importance in quantum computing. In addition, experimental results show that nuclear magnetic resonance spectroscopy can efficiently measure the result of quantum computing without attendant wave-function collapse.

  19. Lymphoma of uterine cervix: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kanaan, Daniel; Constantino, Carolina Pesce Lamas; Souza, Rodrigo Canellas de, E-mail: daniel.kanaan@hotmail.com [Department of Radiology, Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Parente, Daniella Braz [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2012-05-15

    Lymphoma of the cervix is a rare disease. About 1.0% to 1.5% of extranodal lymphomas originates in the female genital tract. The clinical presentation of this condition is nonspecific and magnetic resonance imaging is important for diagnostic elucidation. The present report describes the case of a 80-year-old patient with lumbar pain, whose magnetic resonance imaging showed a large uterine mass. The final diagnosis was lymphoma. (author)

  20. Magnetic resonance imaging of spinal dysraphism

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Minoru; Isu, Toyohiko; Iwasaki, Yoshinobu; Abe, Hiroshi; Abe, Satoru; Miyasaka, Kazuo; Nomura, Mikio; Saito, Hisatoshi.

    1988-04-01

    Nineteen patients with lumbosacral spina bifida were studied by magnetic resonance imaging (MRI) and were divided into two groups: those with lumbosacral lipoma and those with meningomyelocele. All of the patients with meningomyelocele underwent surgery soon after birth for closure of the skin defect. Whenever possible, examination was not confined to the lumbosacral area but also included the brain and other portions of the spinal cord. Certain similarities and differences in pathology were ascertained in the two groups. The tethered cords were the same in both groups. However, Chiari malformations were observed only in patients with meningomyelocele, and hydrocephalus occurred only in patients with Chiari malformations. Syringomyelia and scoliosis were detected in both groups, but scoliosis was more prevalent in the meningomyelocele group. There appeared to be a correlation between scoliosis and syringomyelia; in five of the seven cases of syringomyelia, the locations of the scoliosis and syringomyelia were the same. With MRI, these complex pathologies, including tethered cord, syringomyelia, scoliosis, Chiari malformations, and hydrocephalus, were easily visualized. The superiority of MRI over conventional X-ray technology has been well established. First, a direct image of the spinal cord is obtained. Second, there is no necessity for injection of contrast material into the intrathecal space. Third, any scanning field is possible. There are also some disadvantages with MRI. First, the spatial resolution is inferior to that of high-resolution computed tomography. Second, MRI cannot provide information concerning bone cortex. Therefore, bone involvement cannot be accurately diagnosed. However, in the assessment of spinal dysraphism, MRI is an excellent diagnostic tool and should be the preferred method of diagnosing spinal dysraphism.

  1. Patient perception of magnetic resonance arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, M.I.; Anzilotti, K.F. Jr.; Katz, L.D.; Lange, R.C. [Dept. of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT (United States)

    2000-05-01

    Objective. Magnetic resonance (MR) arthrography has been demonstrated to be more accurate than MR imaging alone in the identification of a variety of musculoskeletal pathology. While the complication rate of intra-articular gadolinium: saline injection has been shown to be relatively low, MR arthrography is more invasive, painful, and costly, and less convenient, than MR imaging alone. The purpose of this study was to evaluate patients' perception of the fear and discomfort, and to assess their overall acceptance of the intra-articular gadolinium injection.Design and patients. Between October 1997 and January 1998, 113 outpatients who were referred to Yale-New Haven Hospital for MR arthrography of the ankle, elbow, hip, knee, shoulder, or wrist were asked to complete a questionnaire rating their fear of factors most commonly associated with the procedure including ''pain'', ''needles'', ''complications'', and ''discovery of results that would lead to surgery''. In addition, after having undergone the intra-articular gadolinium:saline injection, patients were asked to rate their perception of pain.Results. While many patients expressed fear of ''pain'' and ''needles'', after having undergone the injection their overall pain rating score was low. Only 6% actually found gadolinium arthrography more painful than expected.Conclusion. Despite the fact that patients expressed apprehension about certain aspects of MR arthrography, subjects who underwent the intra-articular gadolinium injection considered the discomfort less than expected. Clinicians should not hesitate to order MR arthrography because the accuracy of the procedure is high enough that patients accept the discomfort. (orig.)

  2. Can magnetic resonance spectroscopy differentiate endometrial cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Cai, Shifeng; Han, Xue; Liu, Qingwei; Xin, Yinghui [Shandong University, Department of Radiology, Shandong Provincial Hospital, Jinan (China); Li, Changzhong; Yang, Chunrun [Shandong University, Department of Obstetrics and Gynecology, Shandong Provincial Hospital, Jinan (China); Sun, Xichao; Zong, Yuanyuan [Shandong University, Department of Pathology, Shandong Provincial Hospital, Jinan (China); Fu, Caixia [Siemens Shenzhen Magnetic Resonance Ltd., Siemens MRI Center, Shenzhen (China)

    2014-10-15

    To investigate whether the choline-containing compounds (Cho) obtained from three-dimensional {sup 1}H magnetic resonance (MR) spectroscopy can differentiate endometrial cancer (ECa) from benign lesions in endometria or in submucosa (BLs-ESm) and is associated with the aggressiveness of ECa. Fifty-seven patients (ECa, 38; BLs-ESm, 19) underwent preoperative multi-voxel MR spectroscopy at 3.0 T. The ratio of the sum of the Cho peak integral to the sum of the unsuppressed water peak integral (Cho/water) and the coefficient of variation (CV) used to describe the variability of Cho/water in one lesion were calculated. Mean Cho/water (±standard deviation [SD]) was (3.02 ± 1.43) x 10{sup -3} for ECa and (1.68 ± 0.33) x 10{sup -3} for BLs-ESm (p < 0.001). Mean Cho/water was (4.42 ± 1.53) x 10{sup -3} for type II ECa and (2.65 ± 1.17) x 10{sup -3} for type I ECa (p = 0.001). There were no significant differences among different stages of ECa (p = 0.107) or different grades of ECa (p = 0.142). The Cho/water was positively correlated with tumour stage (r = 0.386, p = 0.017) and size (r = 0.333, p = 0.041). The CV was also positively correlated with tumour stage (r = 0.537, p = 0.001) and size (r = 0.34, p = 0.037). The Cho/water can differentiate ECa from BLs-ESm and differentiate type II from type I ECa, but cannot differentiate different stages of ECa or different grades of ECa. Cho/water increased with the increase of tumour stage and size. (orig.)

  3. Magnetic resonance imaging of spinal cord syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Einsiedel, H. von; Stepan, R.

    1985-05-01

    Thirty-four patients with intramedullary space-occupying lesions or cord compression syndromes were examined with a resistive and two different superconductive magnetic resonance (MR) imaging units. Studies were done primarily by the spin-echo (SE) technique and in the majority of patients different pulse sequences were used. Images with short echo-time (TE) and short recovery-time (TR) were best for demonstration of spinal cord anatomy, for depicting cystic portions in intramedullary tumours and for showing syringomyelia. Solid intramedullary tumours showed normal cord signal intensity. Images with prolonged TE and TR predominantly enhanced CSF signal intensity and, to a more considerable extent, solid intramedullary tumours. Thus, the diameter of the subarachnoid space and the presence of a solid intramedullary tumour, not concomittant with a significant enlargement of the spinal cord, could only be recognized on these prolonged SE images. Major advantages of MR in comparison to CT are that the spinal cord can be imaged in the sagittal plane and that beam hardening artifacts do not occur; in comparison to myelography the cord can be imaged directly by MR. Partial volume is a major limitation of MR, not only in the preferably applied sagittal plane. The choice of slice thickness adequate to the diameter of the lesion and straight positioning of the patient for sagittal single slice midline images are fundamental for reliable MR investigations. Another limitation to MR is that cortical bone gives no signal. The actual diameter of the spinal canal therefore cannot be correctly appreciated and consequently it was difficult or impossible to assess spinal stenosis.

  4. Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Sefrova, Jana, E-mail: sefrova@post.cz [Department of Oncology and Radiotherapy, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Odrazka, Karel [Department of Clinical and Radiation Oncology, Multiscan and Pardubice Regional Hospital, Pardubice (Czech Republic); First and Third Faculty of Medicine, Charles University in Prague, Prague (Czech Republic); Paluska, Petr [Department of Oncology and Radiotherapy, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Belobradek, Zdenek [Department of Radiology, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Brodak, Milos [Department of Urology, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Dolezel, Martin [Department of Clinical and Radiation Oncology, Multiscan and Pardubice Regional Hospital, Pardubice (Czech Republic); First and Third Faculty of Medicine, Charles University in Prague, Prague (Czech Republic); Prosvic, Petr [Department of Urology, Regional Hospital Nachod, Nachod (Czech Republic); Macingova, Zuzana; Vosmik, Milan [Department of Oncology and Radiotherapy, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Hoffmann, Petr [Department of Radiology, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Louda, Miroslav [Department of Urology, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic); Nejedla, Anna [Department of Oncology and Radiotherapy, University Hospital Hradec Kralove, Hradec Kralove (Czech Republic)

    2012-02-01

    Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

  5. Magnetic Resonance Fingerprinting with short relaxation intervals.

    Science.gov (United States)

    Amthor, Thomas; Doneva, Mariya; Koken, Peter; Sommer, Karsten; Meineke, Jakob; Börnert, Peter

    2017-09-01

    The aim of this study was to investigate a technique for improving the performance of Magnetic Resonance Fingerprinting (MRF) in repetitive sampling schemes, in particular for 3D MRF acquisition, by shortening relaxation intervals between MRF pulse train repetitions. A calculation method for MRF dictionaries adapted to short relaxation intervals and non-relaxed initial spin states is presented, based on the concept of stationary fingerprints. The method is applicable to many different k-space sampling schemes in 2D and 3D. For accuracy analysis, T1 and T2 values of a phantom are determined by single-slice Cartesian MRF for different relaxation intervals and are compared with quantitative reference measurements. The relevance of slice profile effects is also investigated in this case. To further illustrate the capabilities of the method, an application to in-vivo spiral 3D MRF measurements is demonstrated. The proposed computation method enables accurate parameter estimation even for the shortest relaxation intervals, as investigated for different sampling patterns in 2D and 3D. In 2D Cartesian measurements, we achieved a scan acceleration of more than a factor of two, while maintaining acceptable accuracy: The largest T1 values of a sample set deviated from their reference values by 0.3% (longest relaxation interval) and 2.4% (shortest relaxation interval). The largest T2 values showed systematic deviations of up to 10% for all relaxation intervals, which is discussed. The influence of slice profile effects for multislice acquisition is shown to become increasingly relevant for short relaxation intervals. In 3D spiral measurements, a scan time reduction of 36% was achieved, maintaining the quality of in-vivo T1 and T2 maps. Reducing the relaxation interval between MRF sequence repetitions using stationary fingerprint dictionaries is a feasible method to improve the scan efficiency of MRF sequences. The method enables fast implementations of 3D spatially resolved

  6. Measurement of single-kidney glomerular filtration function from magnetic resonance perfusion renography

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Meiying; Cheng, Yingsheng [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Shanghai 200233 (China); Zhao, Binghui, E-mail: binghuizhao@163.com [Department of Radiology, Shanghai Tenth People' s Hospital, Tongji University, Shanghai 200072 (China)

    2015-08-15

    Highlights: • MRPR monitors the transit of contrast material through nephron. • MRPR could reveal renal physiological characteristics in quality and quantity. • This review outlines the basics and future challenges of DCE MRPR. - Abstract: Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, they’re all not a good standard to evaluate the early damage of renal function. In recent years, the improvement of MRI hardware and software makes it possible to reveal physiological characteristics such as renal blood flow or GFR by dynamic contrast enhancement magnetic resonance perfusion renography (DEC MRPR). MRPR is a method used to monitor the transit of contrast material, typically a gadolinium chelate, through the renal cortex, the medulla, and the collecting system. This review outlines the basics of DCE MRPR included acquisition of dynamic MR perfusion imaging, calculation of the contrast concentration from signal intensity and compartment models, and some challenges of MRPR method faced in prospective clinical application.

  7. Research progress of magnetic resonance imaging contrast agents

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Magnetic resonance imaging (MRI) is a clinical diagnostic modality, which has become popular in hospitals around the world. Approximately 30% of MRI exams include the use of contrast agents. The research progress of the paramagnetic resonance imaging contrast agents was described briefly. Three important approaches in the soluble paramagnetic resonance imaging contrast agents design including nonionic, tissue-specific and macromolecular contrast agents were investigated. In addition, the problems in the research and development in future were discussed.

  8. Toroidal and magnetic Fano resonances in planar THz metamaterials

    Science.gov (United States)

    Han, Song; Gupta, Manoj; Cong, Longqing; Srivastava, Yogesh Kumar; Singh, Ranjan

    2017-09-01

    The toroidal dipole moment, a localized electromagnetic excitation of torus magnetic fields, has been observed experimentally in metamaterials. However, the metamaterial based toroidal moment was restricted at higher frequencies by the complex three-dimensional structure. Recently, it has been shown that toroidal moment could also be excited in a planar metamaterial structure. Here, we use asymmetric Fano resonators to illustrate theoretically and experimentally the underlying physics of the toroidal coupling in an array of planar metamaterials. It is observed that the anti-parallel magnetic moment configuration shows toroidal excitation with higher quality (Q) factor Fano resonance, while the parallel magnetic moment shows relatively lower Q factor resonance. Moreover, the electric and toroidal dipole interferes destructively to give rise to an anapole excitation. The magnetic dipole-dipole interaction is employed to understand the differences between the toroidal and magnetic Fano resonances. We further study the impact of intra unit-cell coupling between the Fano resonator pairs in the mirrored and non-mirrored arrangements. The numerical and theoretical approach for modelling the near-field effects and experimental demonstration of toroidal and magnetic Fano resonances in planar systems are particularly promising for tailoring the loss in metamaterials across a broad range of the electromagnetic spectrum.

  9. Prostate Cancer: The Role of Multiparametric Magnetic Resonance Imaging.

    Science.gov (United States)

    Dias, João Lopes; Pina, João Magalhães; João, Raquel; Fialho, Joana; Carmo, Sandra; Leal, Cecília; Bilhim, Tiago; Marques, Rui Mateus; Pinheiro, Luís Campos

    2015-01-01

    Multiparametric magnetic resonance imaging has been increasingly used for detection, localization and staging of prostate cancer over the last years. It combines high-resolution T2 weighted-imaging and at least two functional techniques, which include dynamic contrast-enhanced magnetic resonance imaging, diffusion-weighted imaging, and magnetic resonance imaging spectroscopy. Although the combined use of a pelvic phased-array and an endorectal coil is considered the state-of-the-art for magnetic resonance imaging evaluation of prostate cancer, endorectal coil is only absolute mandatory for magnetic resonance imaging spectroscopy at 1.5 T. Sensitivity and specificity levels in cancer detection and localization have been improving with functional technique implementation, compared to T2 weighted-imaging alone. It has been particularly useful to evaluate patients with abnormal PSA and negative biopsy. Moreover, the information added by the functional techniques may correlate to cancer aggressiveness and therefore be useful to select patients for focal radiotherapy, prostate sparing surgery, focal ablative therapy and active surveillance. However, more studies are needed to compare the functional techniques and understand the advantages and disadvantages of each one. This article reviews the basic principles of prostatic mp-magnetic resonance imaging, emphasizing its role on detection, staging and active surveillance of prostate cancer.

  10. Virtual special issue: Magnetic resonance at low fields

    Science.gov (United States)

    Blümich, Bernhard

    2017-01-01

    It appears to be a common understanding that low magnetic fields need to be avoided in magnetic resonance, as sensitivity and the frequency dispersion of the chemical shift increase with increasing field strength. But there many reasons to explore magnetic resonance at low fields. The instrumentation tends to be far less expensive than high-field equipment, magnets are smaller and lighter, internal gradients in heterogeneous media are smaller, conductive media and even metals become transparent at low frequencies to electromagnetic fields, and new physics and phenomena await to be discovered. On account of an increasing attention of the scientific community to magnetic resonance at low field, we have decided to launch JMR's Virtual Special Issue Series with this compilation about Low-Field Magnetic Resonance. This topic, for which we have chosen to focus on articles reporting measurements at fields lower than 2 T, is of widespread interest to our readership. We are therefore happy to offer to this constituency a selected outlook based on papers published during the last five years (volumes 214-270) in the pages of The Journal of Magnetic Resonance. A brief survey of the topics covered in this Virtual Special Issue follows.

  11. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... can interfere with the magnetic field of the MRI unit. The magnetic field is not harmful in ... malfunction or cause problems during the examination. Most MRI exams are relatively painless. However, some patients may ...

  12. Magnetic Resonance, Functional (fMRI) -- Brain

    Science.gov (United States)

    ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  13. Magnetic Resonance (MR)-Guided Breast Biopsy

    Science.gov (United States)

    ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table that slides into the center of the magnet. Some MRI units, called short-bore systems , are ...

  14. All-fiber magnetic-field sensor based on microfiber knot resonator and magnetic fluid.

    Science.gov (United States)

    Li, Xianli; Ding, Hui

    2012-12-15

    All-fiber magnetic-field sensor based on a device consisting of a microfiber knot resonator and magnetic fluid is proposed for the first time in this Letter. Sensor principles and package technology are introduced in detail. Experimental results show that the resonance wavelength of the proposed sensor regularly varies with changes to the applied magnetic field. When the magnetic field is increased to 600 Oe, the wavelength shift reaches nearly 100 pm. Moreover, the sensor responding to the 50 Hz alternating magnetic field is also experimentally investigated, and a minimal detectable magnetic-field strength of 10 Oe is successfully achieved.

  15. Pulse Design in Solid-State Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Palani, Ravi Shankar

    2017-01-01

    The work presented in this dissertation is centred on the theory of experimental methods in solid-state Nuclear Magnetic Resonance (NMR) spectroscopy, which deals with interaction of electromagnetic radiation with nuclei in a magnetic field and possessing a fundamental quantum mechanical property...

  16. A Quantum Mechanical Review of Magnetic Resonance Imaging

    CERN Document Server

    Odaibo, Stephen G

    2012-01-01

    In this paper, we review the quantum mechanics of magnetic resonance imaging (MRI). We traverse its hierarchy of scales from the spin and orbital angular momentum of subatomic particles to the ensemble magnetization of tissue. And we review a number of modalities used in the assessment of acute ischemic stroke and traumatic brain injury.

  17. Evaluation of left ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Thomsen, C; Mehlsen, J

    1986-01-01

    Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared...

  18. Terahertz Magnetic Mirror Realized with Dielectric Resonator Antennas.

    Science.gov (United States)

    Headland, Daniel; Nirantar, Shruti; Withayachumnankul, Withawat; Gutruf, Philipp; Abbott, Derek; Bhaskaran, Madhu; Fumeaux, Christophe; Sriram, Sharath

    2015-11-25

    Single-crystal silicon is bonded to a metal-coated substrate and etched in order to form an array of microcylinder passive terahertz dielectric resonator antennas (DRAs). The DRAs exhibit a magnetic response, and hence the array behaves as an efficient artificial magnetic conductor (AMC), with potential for terahertz antenna and sensing applications.

  19. The Nobel Prize in Medicine for Magnetic Resonance Imaging

    Science.gov (United States)

    Fry, Charles G.

    2004-01-01

    Nobel Prize in Medicine awarded in December 2003 to chemist Paul C. Lauterbur and physicist Peter Mansfield for the development of magnetic resonance imaging (MRI), a long overdue recognition of the huge impact MRI has had in medical diagnostics and research is mentioned. MRI was derived, and remains an extension of nuclear magnetic resonance…

  20. A Faraday effect position sensor for interventional magnetic resonance imaging.

    Science.gov (United States)

    Bock, M; Umathum, R; Sikora, J; Brenner, S; Aguor, E N; Semmler, W

    2006-02-21

    An optical sensor is presented which determines the position and one degree of orientation within a magnetic resonance tomograph. The sensor utilizes the Faraday effect to measure the local magnetic field, which is modulated by switching additional linear magnetic fields, the gradients. Existing methods for instrument localization during an interventional MR procedure often use electrically conducting structures at the instruments that can heat up excessively during MRI and are thus a significant danger for the patient. The proposed optical Faraday effect position sensor consists of non-magnetic and electrically non-conducting components only so that heating is avoided and the sensor could be applied safely even within the human body. With a non-magnetic prototype set-up, experiments were performed to demonstrate the possibility of measuring both the localization and the orientation in a magnetic resonance tomograph. In a 30 mT m(-1) gradient field, a localization uncertainty of 1.5 cm could be achieved.

  1. Filling defect artefacts in magnetic resonance urography

    Energy Technology Data Exchange (ETDEWEB)

    Girish, G.; Chooi, W.K.; Morcos, S.K. [Department of Diagnostic Imaging, Northern General Hospital, Sheffield Teaching Hospitals NHS Trust, S5 7AU, Sheffield (United Kingdom)

    2004-01-01

    The aim of this study was to determine the prevalence of filling defect artefacts (FDA) in magnetic resonance urography (MRU). Retrospectively, we assessed MRU examinations of 45 patients with neurogenic bladder dysfunction (21 men, 24 women; mean age 35 years, age range 18-71 years). The MRU was performed 30 min after intramuscular injection of 20 mg frusemide using heavily T2-weighted fast-spin-echo techniques [axial, thick coronal slab, coronal maximum intensity projection (MIP) images] with fat saturation. The images were reviewed by two observers to determine the presence of filling defects and dilatation of pelvicalyceal system and ureters. The filling defects were classified into central, eccentric and complete. Clinical course and plain films were reviewed to determine significance of the detected filling defects. True filling defects were observed in 5 patients (11%) and all due to stones seen on the plain radiograph of the abdomen. Filling defects artefacts (FDAs) were seen in 23 patients (51%; 17 pelvicalyceal system, 17 upper third of ureters, 7 mid ureters and 1 distal ureter). No stones were seen on the plain radiograph of these patients and they had a favourable clinical course for over 24 months. The true filling defects were large in size, eccentric in position and seen in more than one sequence of the MRU examination (axial, n=5; slab, n=5; and MIP, n=4). Four (80%) of the patients with true defects and 21 (91%) of those with FDAs had dilatation of the pelvicalyceal system and ureters. The FDAs were small in size, centrally placed (74%) and always seen in axial images, rarely in slab images (2 cases) and not seen in MIP images. Artefactual filling defects can be seen in MRU examinations. The cause of the FDAs is not fully explained and could be secondary to turbulent and fast flow of the urine. Some of the FDAs seen in the calyces could be due to the tips of the papillae. Awareness of such defects obviates misinterpretation and prevents

  2. Myocardial Viability on Cardiac Magnetic Resonance.

    Science.gov (United States)

    Souto, Ana Luiza Mansur; Souto, Rafael Mansur; Teixeira, Isabella Cristina Resende; Nacif, Marcelo Souto

    2017-05-01

    The study of myocardial viability is of great importance in the orientation and management of patients requiring myocardial revascularization or angioplasty. The technique of delayed enhancement (DE) is accurate and has transformed the study of viability into an easy test, not only for the detection of fibrosis but also as a binary test detecting what is viable or not. On DE, fibrosis equal to or greater than 50% of the segmental area is considered as non-viable, whereas that below 50% is considered viable. During the same evaluation, cardiac magnetic resonance (CMR) may also use other techniques for functional and perfusion studies to obtain a global evaluation of ischemic heart disease. This study aims to highlight the current concepts and broadly emphasize the use of CMR as a method that over the last 20 years has become a reference in the detection of infarction and assessment of myocardial viability. Resumo O estudo de viabilidade miocárdica é de grande importância para a orientação e manejo de pacientes que necessitam de cirurgia de revascularização miocárdica ou angioplastia. A técnica de realce tardio (RT) é precisa e transformou o estudo de viabilidade em um teste fácil, não só para a detecção de fibrose, mas também como um modelo binário para a detecção do que é ou não é viável. Uma fibrose identificada pelo RT é considerada como não viável quando igual ou maior do que 50% da área segmentar e como viável quando menor que 50%. A ressonância magnética cardíaca (RMC) também pode lançar mão de outras técnicas para estudo funcional e de perfusão para uma avaliação global da doença isquêmica do coração no mesmo exame. Este estudo tem como objetivo destacar os conceitos atuais e enfatizar amplamente o uso da RMC como um método que nos últimos 20 anos se tornou referência na detecção de infarto e avaliação de viabilidade miocárdica.

  3. Spatially coherent surface resonance states derived from magnetic resonances

    CERN Document Server

    Wei, Zeyong; Cao, Yang; Wu, Chao; Ren, Jinzhi; Hang, Zhihong; Chen, Hong; Zhang, Daozhong; Chan, C T

    2010-01-01

    A thin metamaterial slab comprising a dielectric spacer sandwiched between a metallic grating and a ground plane is shown to possess spatially coherent surface resonance states that span a large frequency range and can be tuned by structural and material parameters. They give rise to nearly perfect angle-selective absorption and thus exhibit directional thermal emissivity. Direct numerical simulations show that the metamaterial slab supports spatially coherent thermal emission in a wide frequency range that is robust against structural disorder.

  4. Magnetically tunable Mie resonance-based dielectric metamaterials.

    Science.gov (United States)

    Bi, Ke; Guo, Yunsheng; Liu, Xiaoming; Zhao, Qian; Xiao, Jinghua; Lei, Ming; Zhou, Ji

    2014-11-11

    Electromagnetic materials with tunable permeability and permittivity are highly desirable for wireless communication and radar technology. However, the tunability of electromagnetic parameters is an immense challenge for conventional materials and metamaterials. Here, we demonstrate a magnetically tunable Mie resonance-based dielectric metamaterials. The magnetically tunable property is derived from the coupling of the Mie resonance of dielectric cube and ferromagnetic precession of ferrite cuboid. Both the simulated and experimental results indicate that the effective permeability and permittivity of the metamaterial can be tuned by modifying the applied magnetic field. This mechanism offers a promising means of constructing microwave devices with large tunable ranges and considerable potential for tailoring via a metamaterial route.

  5. Parahydrogen enhanced zero-field nuclear magnetic resonance

    OpenAIRE

    Theis, Thomas; Ganssle, Paul; Kervern, Gwendal; Knappe, Svenja; Kitching, John; Ledbetter, Micah; Budker, Dmitry; Pines, Alex

    2011-01-01

    Nuclear magnetic resonance (NMR), conventionally detected in multi-tesla magnetic fields, is a powerful analytical tool for the determination of molecular identity, structure, and function. With the advent of prepolarization methods and alternative detection schemes using atomic magnetometers or superconducting quantum interference devices (SQUIDs), NMR in very low- (~earth's field), and even zero-field, has recently attracted considerable attention. Despite the use of SQUIDs or atomic magnet...

  6. Spin microscope based on optically detected magnetic resonance

    Science.gov (United States)

    Berman, Gennady P.; Chernobrod, Boris M.

    2007-12-11

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  7. Characterization of magnetically actuated resonant cantilevers in viscous fluids

    Science.gov (United States)

    Vančura, Cyril; Lichtenberg, Jan; Hierlemann, Andreas; Josse, Fabien

    2005-10-01

    The vibration behavior of magnetically actuated resonant microcantilevers immersed in viscous fluids has been studied. A dependence of the resonance frequency and the quality factor (Q factor) on the fluid properties, such as density and viscosity and on the cantilever geometry is described. Various cantilever geometries are analyzed in pure water and glycerol solutions, and the results are explained in terms of the added displaced fluid mass and the fluid damping force for both the resonance frequency and the quality factor. An in-depth knowledge and understanding of such systems is necessary when analyzing resonant cantilevers as biochemical sensors in liquid environments.

  8. Quantum transport in coupled resonators enclosed synthetic magnetic flux

    Science.gov (United States)

    Jin, L.

    2016-07-01

    Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov-Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms.

  9. Magnetic resonance urography in children – when and why?

    Science.gov (United States)

    Vegar-Zubovic, Sandra; Kristic, Spomenka; Lincender, Lidija

    2011-01-01

    Background The aim of the study was to determine the potential of magnetic resonance urography (MRU) in evaluation of paediatric urinary tract pathologies. Patients and methods. Twenty-one paediatric urological patients were evaluated with T1, T2 prior and after and 3D gradient echo sequences after the contrast administration. Results were compared with findings obtained with ultrasound which was performed to all of patients, intravenous urography performed to 14 patients with the diagnosis of hydronephrosis and voiding cystouretrography performed to 6 patients where hydronephrosis was suspected to be caused by vesicoureteral reflux (VUR). Results MRU not only established the cause of hydronephrosis in all 14 cases (5 ureteropelvic junction (UPJ) stenosis, 1 functional stenosis, 3 residual hydronephrosis, 1 combination of UPJ and vesico-ureteric junction (VUJ) stenosis with hydromegaureter, 2 fetal ureters and 3 insufficient broad ureteral orifices), but gave additional information about existing pathological conditions in all of patients compared to other previously performed examination (1 caliceal lithiasis, 4 UPJ stenosis, 1 VUJ stenosis, 1 neurogenic bladder, 1 hypotonic ureter, 1 urinary infection, 1 duplication of pelvis and ureter, 1 urinary retention and 1 fetal ureter). Other MRU findings were: 3 polycystic kidney disease, 1 caliceal cyst, 2 simple renal cysts, 1 long hypotonic twisted ureters and 1 hypertrophied column of Bertini. Conclusions Because of the ability to acquire high contrast and spatial resolution images of the whole urinary tract in any orthogonal plane, MRU enables a precise detection and differentiation of pathological urological conditions. We believe that in the future, because of its advantages, MRU will replace traditional methods in the evaluation of urinary tract pathologies. PMID:22933952

  10. Magnetic resonance urography in children - when and why?

    Science.gov (United States)

    Vegar-Zubovic, Sandra; Kristic, Spomenka; Lincender, Lidija

    2011-09-01

    The aim of the study was to determine the potential of magnetic resonance urography (MRU) in evaluation of paediatric urinary tract pathologies. PATIENTS AND METHODS.: Twenty-one paediatric urological patients were evaluated with T1, T2 prior and after and 3D gradient echo sequences after the contrast administration. Results were compared with findings obtained with ultrasound which was performed to all of patients, intravenous urography performed to 14 patients with the diagnosis of hydronephrosis and voiding cystouretrography performed to 6 patients where hydronephrosis was suspected to be caused by vesicoureteral reflux (VUR). MRU not only established the cause of hydronephrosis in all 14 cases (5 ureteropelvic junction (UPJ) stenosis, 1 functional stenosis, 3 residual hydronephrosis, 1 combination of UPJ and vesico-ureteric junction (VUJ) stenosis with hydromegaureter, 2 fetal ureters and 3 insufficient broad ureteral orifices), but gave additional information about existing pathological conditions in all of patients compared to other previously performed examination (1 caliceal lithiasis, 4 UPJ stenosis, 1 VUJ stenosis, 1 neurogenic bladder, 1 hypotonic ureter, 1 urinary infection, 1 duplication of pelvis and ureter, 1 urinary retention and 1 fetal ureter). Other MRU findings were: 3 polycystic kidney disease, 1 caliceal cyst, 2 simple renal cysts, 1 long hypotonic twisted ureters and 1 hypertrophied column of Bertini. Because of the ability to acquire high contrast and spatial resolution images of the whole urinary tract in any orthogonal plane, MRU enables a precise detection and differentiation of pathological urological conditions. We believe that in the future, because of its advantages, MRU will replace traditional methods in the evaluation of urinary tract pathologies.

  11. Magnetic resonance imaging of idiopathic osteonecrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Yamazoe, Shoichi [Kyoto Prefectural Univ. of Medicine (Japan)

    1995-02-01

    Idiopathic osteonecrosis of the femoral head (IONF) can result in disability due to bone collapse and destruction. Therefore, early diagnosis of IONF and prognosis assessment are essential for treatment planning. This study investigated the early characteristic pattern of IONF on magnetic resonance imaging (MRI) and its correlation to the prognosis of the femoral head. MRI was performed repeatedly on fifty-one patients who had undergone renal transplantation. Three abnormal patterns were found in the T{sub 1}-weighted images: a band-like low-signal pattern (band pattern), an irregular low-signal pattern (mottled pattern), and a homogeneous low-signal area localized in the subchondral region (homogeneous pattern). Abnormal changes were detected in thirteen patients; twenty-three hips (25.5%). Most changes were evident within six months after transplantation. The earliest was found six weeks after transplantation. A band pattern was the initial finding in all hips showing abnormal changes. The band pattern did not spread peripherally as time passed. There was no progression from a mottled or homogeneous pattern to a band pattern either. Band-like patterns were subclassified into four types: MR-A, MR-B, MR-C and MR-D. Each of types according to the size and location of the band in relation to the weight bearing portion of the acetabulum was correlated to the prognosis of the femoral head. Three fourths of femoral heads with MR-C resulted in collapse on roentgenographs. These results show that MRI is useful for the diagnosis and evaluation of prognosis in IONF. (author).

  12. Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy Characterize a Rodent Model of Covert Stroke

    Science.gov (United States)

    Herrera, Sheryl Lyn

    Covert stroke (CS) comprises lesions in the brain often associated by risk factors such as a diet high in fat, salt, cholesterol and sugar (HFSCS). Developing a rodent model for CS incorporating these characteristics is useful for developing and testing interventions. The purpose of this thesis was to determine if magnetic resonance (MR) can detect brain abnormalities to confirm this model will have the desired anatomical effects. Ex vivo MR showed brain abnormalities for rats with the induced lesions and fed the HFSCS diet. Spectra acquired on the fixed livers had an average percent area under the fat peak relative to the water peak of (20+/-4)% for HFSCS and (2+/-2)% for control. In vivo MR images had significant differences between surgeries to induce the lesions (p=0.04). These results show that applying MR identified abnormalities in the rat model and therefore is important in the development of this CS rodent model.

  13. Quantum transport in coupled resonators enclosed synthetic magnetic flux

    Energy Technology Data Exchange (ETDEWEB)

    Jin, L., E-mail: jinliang@nankai.edu.cn

    2016-07-15

    Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov–Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms. -- Highlights: •The light transport is investigated through ring array of coupled resonators enclosed synthetic magnetic field. •Aharonov–Bohm ring interferometer of arbitrary configuration is investigated. •The half-integer magnetic flux quantum leads to destructive interference and transmission zeros for two-arm at equal length. •Complete transmission is available via tuning synthetic magnetic flux.

  14. Dysembryoplastic neuroepithelial tumors: magnetic resonance imaging and magnetic resonance spectroscopy evaluation

    Institute of Scientific and Technical Information of China (English)

    YU Ai-hong; CHEN Li; LI Yong-jie; ZHANG Guo-jun; LI Kun-cheng; WANG Yu-ping

    2009-01-01

    Background Dysembryoplastic neuroepithelial tumor (DNT) is a rare benign neoplasm of the central nervous system affecting young people. A correct preoperative diagnosis is helpful for planning surgical strategies and improving prognosis. The purpose of this study was to characterize DNTs using magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) and to analyze the value of these two techniques in the diagnosis of DNTs.Methods MR images of 13 patients with DNTs were reviewed retrospectively; and five of the patients also underwent MRS. Tumors were confirmed by surgery. The distribution, extension and signal features of the lesions were assessed,and the MRS results were analyzed.Results All tumors were supratentorial. The cortex was the main area involved, with nine tumors located in the temporal lobe, three in the frontal lobe, and one on the boundary between the temporal and occipital lobes. All cases had decreased signal intensity on T1-weighted MR images and increased signal intensity on T2-weighted images. On fluid attenuated inversion recovery weighted images, the hyperintense "ring sign" and internal septation of the lesion were seen in 9 cases. Eight tumors had well-demarcated borders. Peritumoral edema or mass effect was absent in all cases. A contrast enhancement examination was performed in 9 cases. Contrast enhancement was absent in five cases, and four cases showed significant enhancement. The MRS showed a low N-acetylaspartate peak and a lack of elevated choline-containing component (Cho) or Cho-Cr ratio (Cho/Cr) in five patients.Conclusions The MRI findings of DNTs were stereotypical. The combination of MRI and MRS techniques were helpful in making a correct presurgical diagnosis.

  15. Chronic hepatosplenic schistosomiasis mansoni: magnetic resonance imaging and magnetic resonance angiography findings

    Energy Technology Data Exchange (ETDEWEB)

    Bezerra, A.S.; D' Ippolito, G.; Caldana, R.P.; Cecin, A.O.; Ahmed, M.; Szejnfeld, J. [Dept. of Diagnostic Imaging, Federal Univ. of Sao Paulo, Sao Paulo (Brazil)

    2007-02-15

    Purpose: To evaluate the hepatosplenic manifestations and the portal venous system in patients with chronic infection by Schistosoma mansoni. Material and Methods: A cross-sectional observational study was performed in 28 patients with chronic hepatosplenic schistosomiasis submitted to magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) of the abdomen. Images were interpreted independently by two radiologists to determine the reproducibility of image interpretation and who evaluated the presence of morphological alterations in the liver and spleen, such as hepatosplenomegaly, hepatic fissure widening, periportal fibrosis, and the presence of siderotic nodules. Interobserver and intra-observer agreement were measured with the kappa and intraclass correlation tests. Evaluation of venous collateral pathways and portal and splenic veins was done in consensus by both examiners. Results: Observers identified enlargement of the left lobe (78.5-92.8%) and caudate-to-right-lobe ratio (78.5-92.8%), irregularity of hepatic contours (89.2-96.4%), fissure widening (89.2-100%), and splenic siderotic nodules (84.2%). Splenomegaly, heterogeneity of hepatic parenchyma, peripheral hepatic vessels, and periportal fibrosis were observed in 100% of patients. MRI findings presented almost perfect interobserver (kappa 0.65-1) and intra-observer (kappa = 0.73-1 for observer 1, and kappa = 0.65-1 for observer 2) agreement for the variables analyzed. MRA showed the presence of collateral pathways in the majority of patients (71.4%) along with widening of portal and splenic veins. Conclusion: Using MRI, hepatosplenic alterations in schistosomiasis are characterized by heterogeneity of hepatic parenchyma, presence of peripheral perihepatic vessels, periportal fibrosis, splenomegaly, siderotic nodules, and the presence of venous collateral pathways.

  16. Rotational characteristics in the resonance state of the HTSC-permanent magnet hybrid magnetic bearing

    Energy Technology Data Exchange (ETDEWEB)

    Morii, Y.; Sukedai, M. [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan); Ohashi, S., E-mail: ohashi@kansai-u.ac.jp [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)

    2011-11-15

    The hybrid magnetic bearing has been developed. In the hybrid system, effect of the pinning force becomes smaller. Influence of the vibration and the gradient angle in the resonance state is large. The resonance frequency becomes small in the hybrid bearing system. The hybrid magnetic bearing using permanent magnets and the high-Tc bulk superconductor (HTSC) has been developed. Repulsive force of the permanent magnet is introduced to increase the load weight of the magnetic bearing. Effect of the hybrid system has been shown. In this paper, influence of the hybrid system on the dynamic characteristics of the rotor is studied. The rotational characteristics in the mechanical resonance state are studied, and the equivalent magnetic spring coefficient is estimated from the experimental results of the load weight. The resonance frequency is measured by the rotation experiments. The rotor achieves stable levitation even in the resonance state. In the hybrid system, effect of the pinning force becomes smaller than that of the lateral force generated by the repulsive force between the two permanent magnets at the smaller air gap. Thus influence of the lateral vibration and the gradient angle in the resonance state becomes larger at a smaller air gap. The equivalent magnetic spring coefficient becomes also small, and the resonance frequency becomes small in the hybrid bearing system.

  17. Comparison of nuclear electric resonance and nuclear magnetic resonance in integer and fractional quantum Hall states

    Directory of Open Access Journals (Sweden)

    Toru Tomimatsu

    2015-08-01

    Full Text Available Electric-field-induced nuclear resonance (NER: nuclear electric resonance involving quantum Hall states (QHSs was studied at various filling factors by exploiting changes in nuclear spins polarized at quantum Hall breakdown. Distinct from the magnetic dipole interaction in nuclear magnetic resonance, the interaction of the electric-field gradient with the electric quadrupole moment plays the dominant role in the NER mechanism. The magnitude of the NER signal strongly depends on whether electronic states are localized or extended. This indicates that NER is sensitive to the screening capability of the electric field associated with QHSs.

  18. Three-dimensional magnetic recording using ferromagnetic resonance

    Science.gov (United States)

    Suto, Hirofumi; Kudo, Kiwamu; Nagasawa, Tazumi; Kanao, Taro; Mizushima, Koichi; Sato, Rie

    2016-07-01

    To meet the ever-increasing demand for data storage, future magnetic recording devices will need to be made three-dimensional by implementing multilayer recording. In this article, we present methods of detecting and manipulating the magnetization direction of a specific layer selectively in a vertically stacked multilayer magnetic system, which enable layer-selective read and write operations in three-dimensional magnetic recording devices. The principle behind the methods is ferromagnetic resonance excitation in a microwave magnetic field. By designing each magnetic recording layer to have a different ferromagnetic resonance frequency, magnetization excitation can be induced individually in each layer by tuning the frequency of an applied microwave magnetic field, and this selective magnetization excitation can be utilized for the layer-selective operations. Regarding media for three-dimensional recording, when layers of a perpendicular magnetic material are vertically stacked, dipolar interaction between multiple recording layers arises and is expected to cause problems, such as degradation of thermal stability and switching field distribution. To solve these problems, we propose the use of an antiferromagnetically coupled structure consisting of hard and soft magnetic layers. Because the stray fields from these two layers cancel each other, antiferromagnetically coupled media can reduce the dipolar interaction.

  19. resonant inverter supplied interior permanent magnet (ipm)

    African Journals Online (AJOL)

    user

    Permanent Magnet (IPM) or Surface Permanent. Magnet ... desired torque is produced to rotate the motor in the desired ... u axis, and the direct-axis of the rotor is at angle θ from the ..... Based Stator Flux Estimator” International. Journal of ...

  20. Magnetic Resonance Imaging Studies of Postpartum Depression: An Overview

    Directory of Open Access Journals (Sweden)

    Marco Fiorelli

    2015-01-01

    Full Text Available Postpartum depression is a frequent and disabling condition whose pathophysiology is still unclear. In recent years, the study of the neural correlates of mental disorders has been increasingly approached using magnetic resonance techniques. In this review we synthesize the results from studies on postpartum depression in the context of structural, functional, and spectroscopic magnetic resonance studies of major depression as a whole. Compared to the relative wealth of data available for major depression, magnetic resonance studies of postpartum depression are limited in number and design. A systematic literature search yielded only eleven studies conducted on about one hundred mothers with postpartum depression overall. Brain magnetic resonance findings in postpartum depression appear to replicate those obtained in major depression, with minor deviations that are not sufficient to delineate a distinct neurobiological profile for this condition, due to the small samples used and the lack of direct comparisons with subjects with major depression. However, it seems reasonable to expect that studies conducted in larger populations, and using a larger variety of brain magnetic resonance techniques than has been done so far, might allow for the identification of neuroimaging signatures for postpartum depression.