WorldWideScience

Sample records for renal clearance measurements

  1. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  2. Preparation of iodine-125-labeled iothalamate for renal clearance measurements

    International Nuclear Information System (INIS)

    Rao, S.A.; Herold, T.J.; Dewanjee, M.K.

    1983-01-01

    Iothalamate, a derivative of benzoic acid, is used as a contrast medium for renal function studies, particularly for measurement of glomerular filtration rate. Its chemical composition and clearance properties are similar to those of diatrizoate. The structural differences between these groups of iodinated benzoic acid derivatives are dependent on the groups attached at the 3- and 5-positions of 2,4,6-tri-iodobenzoic acid. The renal clearance of sodium iothalamate in humans closely approximates that of inulin, and it is used as a replacement for inulin in determining glomerular filtration rate. /sup 125/I-labeled iothalamate sodium can be prepared by the exchange-labeling method at pH 4.0. Iothalamate must first be isolated from the contrast medium preparation and purified before radioiodination. After radioiodination, the product is purified by means of precipitation and is then converted to the sodium salt

  3. Comparison of clearance and arteriovenous extraction techniques for measurements of renal hemodynamic functions

    International Nuclear Information System (INIS)

    Katzberg, R.W.; Pabico, R.C.; Morris, T.W.; Hayakawa, K.; McKenna, B.A.; Ventura, J.A.; Fischer, H.W.

    1986-01-01

    No previous studies have directly compared timed urine collections (UV/P) vs. arteriovenous (A-V) extraction methods for determination of renal function in whole kidney preparations. We examined different markers and techniques for assessing renal plasma flow (RPF), filtration fraction (FF), and glomerular filtration rate (GFR) in both steady-state and rapidly changing conditions following 2 ml/kg bolus intravenous injections of either Renografin 76% (meglumine/sodium diatrizoate-76%) or hypertonic mannitol 25%. During steady-state conditions, excellent correlations were obtained when comparing markers and techniques. Thus, timed urinary clearances of inulin vs. 99m-technetium DTPA (Tc) had a correlation coefficient (R) of .96 (P less than .01; n = 16), and the A-V extraction technique of inulin vs. Tc as determinants of GFR showed a correlation of R = .98 (P less than .01; n = 15). The timed urinary clearance of inulin vs. the A-V extraction of inulin for glomerular filtration gave a correlation of R = .93 (P less than .01; n = 15). The clearance of para-aminohippurate (PAH) divided by the extraction of PAH vs. flow determinations using the electromagnetic flowmeter gave a correlation of R = .92 (P less than .01; n = 16). The anticipated decrease in GFR following contrast medium and hypertonic mannitol was observed using the A-V extraction technique, whereas an artifactual, exaggerated increase in GFR was observed using the timed urine collection technique. Similarly, we noted an exaggerated increase in RPF using CPAH/EPAH as the methodology. We conclude that rapid changes in renal hemodynamics may be measured accurately using the A-V extraction technique but not with clearance techniques requiring timed urine collections

  4. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  5. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Science.gov (United States)

    Luis-Lima, Sergio; García-Contreras, Consolación; Carrara, Fabiola; Negrín-Mena, Natalia; Jiménez-Sosa, Alejandro; Jiménez-Hernández, Hugo; Porrini, Esteban

    2018-01-01

    There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1) − (0.00063968xCL12). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials. PMID:29329247

  6. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Directory of Open Access Journals (Sweden)

    Sergio Luis-Lima

    2018-01-01

    Full Text Available There is no simple method to measure glomerular filtration rate (GFR in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g was injected into the marginal auricular vein and blood samples (3 mL were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples and one-compartment (CL1: the last six samples. In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1 − (0.00063968xCL12. The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials.

  7. Comparison of measurement of 99mTc-MAG3 plasma clearance by single plasma sample and renal uptake ratio

    International Nuclear Information System (INIS)

    Ushijima, Yo; Sugihara, Hiroki; Okuyama, Chio; Okitsu, Sigeyuki; Nii, Takeshi; Nishida, Takuji; Okamoto, Kunio; Maeda, Tomoho

    1997-01-01

    Measurement of 99m Tc-MAG 3 plasma clearance based on one-compartment model (MPC method) is a non-invasive method using the renal uptake ratio. We evaluated the clinical usefulness of this method, compared with effective renal plasma flow (ERPF) using 123 I-OIH and two single-plasma sample methods using 99m Tc-MAG 3 (Russell method and Bubeck method). The ratio of 99m Tc-MAG 3 clearance to ERPF was 1.00±0.26. MPC method correlated well with Russell and Bubeck methods (r=0.904, r=0.897). We conclude that MPC method is a suitable replacement for single-plasma sample method in routine clinical use. (author)

  8. Servo-control of water and sodium homeostasis during renal clearance measurements in conscious rats

    DEFF Research Database (Denmark)

    Thomsen, Klaus; Shirley, David G

    2007-01-01

    Servo-controlled fluid and sodium replacement during clearance studies is used in order to prevent loss of body fluid and sodium following diuretic/natriuretic procedures. However, even under control conditions, the use of this technique is sometimes associated with increases in proximal tubular...... fluid output (assessed by lithium clearance) and excretion rates. The present study examined the reason for these increases. The first series of experiments showed that one cause is volume overloading. This can occur if the servo system is activated from the start, i.e., during the establishment...... not seen when blood samples are replaced with the animal's own red blood cells resuspended in isotonic saline. When these pitfalls are avoided, servo-controlled sodium and fluid replacement is a reliable technique that makes it possible to study the effects of natriuretic and/or diuretic stimuli without...

  9. Renal I-131-hippurate clearance overestimates true renal blood flow in the instrumented conscious dog

    NARCIS (Netherlands)

    Visscher, CA; DeZeeuw, D; Navis, G; VanZanten, AK; DeJong, PE; Huisman, RM

    We evaluated renal I-131-hippurate clearance (ERPF(hip)) as a measure of renal blood flow (RBF) in chronically instrumented conscious dogs. When adjusted for renal hippurate extraction (E(hip), 0.77 +/- 0.01) and hematocrit (Hct, 39.7 +/- 1%), calculated RBF(hip) (656 +/- 37 ml/min) markedly

  10. Servo-control of water and sodium homeostasis during renal clearance measurements in conscious rats.

    Science.gov (United States)

    Thomsen, Klaus; Shirley, David G

    2007-01-01

    Servo-controlled fluid and sodium replacement during clearance studies is used in order to prevent loss of body fluid and sodium following diuretic/natriuretic procedures. However, even under control conditions, the use of this technique is sometimes associated with increases in proximal tubular fluid output (assessed by lithium clearance) and excretion rates. The present study examined the reason for these increases. The first series of experiments showed that one cause is volume overloading. This can occur if the servo system is activated from the start, i.e., during the establishment of a suitably high urine flow rate by constant infusion of hypotonic glucose solution. The second series of experiments showed that replacement of blood samples with donor blood can also lead to increases in fractional lithium excretion and accompanying increases in water and sodium excretion, a problem not seen when blood samples are replaced with the animal's own red blood cells resuspended in isotonic saline. When these pitfalls are avoided, servo-controlled sodium and fluid replacement is a reliable technique that makes it possible to study the effects of natriuretic and/or diuretic stimuli without interference from unwanted changes in extracellular volume. 2007 S. Karger AG, Basel

  11. Renal clearance of /sup 99m/Tc-methylene-diphosphonate in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.

    1987-12-01

    The renal clearance of /sup 99m/Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of /sup 51/Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the /sup 99m/Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion.

  12. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  13. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  14. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  15. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  16. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  17. Investigations of renal clearance in nuclear medicine

    International Nuclear Information System (INIS)

    Oberhausen, E.

    1981-01-01

    Comparative investigations of PAH- and inulin-clearance and results of investigations with J-131-hippurate and Cr-51-EDTA, which were performed by a partly screened whole body counter including measurements of activity retention of blood samples, are showing good correlation. If the radio-isotope nephrography is worked out together with the decreased retention curve, separate results of the function of both kidneys can be given. Modifications which were tried to analyze a small part of the retention curve instead of the whole body are inaccurate, if they are below 300 ml/min. (orig.) [de

  18. Comparison between total and renal plasma clearance of [51Cr]EDTA

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    The total plasma (E 1 ) and renal plasma (E 2 ) clearances of [ 51 Cr]EDTA were measured simultaneously in 40 patients with a wide range of renal function. The regression equation was E 1 = 0.997E 2 + 4.1; the slope of the regression line was not significantly different from 1.00, and the intercept differed significantly from zero. The results suggest that [ 51 Cr]EDTA has a significant extrarenal clearance of approximately 4 ml/min, independent of renal function. The data are used to correct the total [ 51 Cr]EDTA plasma clearance, measured by a simplified method, to yield a rapid, accurate and precise measurement of glomerular filtration rate for routine clinical use. (Auth.)

  19. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  20. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  1. Glomerular filtration rate measured by {sup 51}Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit, E-mail: annaalice100@yahoo.com.b [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2010-07-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using {sup 51}Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ({sup 51}Cr-EDTA) and {sup 99m}Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6+-21.8 ml/kg/1.73 m{sup 2} in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1+-28.7 ml/kg/1.73m{sup 2} in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6+-14.8 ml/kg/1.73m{sup 2}, p=0.001) and an insignificant change in the group without RAS (to 62.2+-23.6 ml/kg/1.73m{sup 2}, p=0.68). Scintigraphy with technetium-99m dimercapto

  2. Glomerular filtration rate measured by 51Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    International Nuclear Information System (INIS)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit

    2010-01-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ( 51 Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using 51 Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ( 51 Cr-EDTA) and 99m Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6±21.8 ml/kg/1.73 m 2 in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1±28.7 ml/kg/1.73m 2 in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6±14.8 ml/kg/1.73m 2 , p=0.001) and an insignificant change in the group without RAS (to 62.2±23.6 ml/kg/1.73m 2 , p=0.68). Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA) did not show

  3. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  4. Effect of glycation of albumin on its renal clearance in normal and diabetic rats

    International Nuclear Information System (INIS)

    Layton, G.J.; Jerums, G.

    1988-01-01

    Two independent techniques have been used to study the renal clearances of nonenzymatically glycated albumin and nonglycated albumin in normal and streptozotocin-induced diabetic rats, 16 to 24 weeks after the onset of diabetes. In the first technique, serum and urinary endogenous glycated and nonglycated albumin were separated using m-aminophenylboronate affinity chromatography and subsequently quantified by radioimmunoassay. Endogenous glycated albumin was cleared approximately twofold faster than nonglycated albumin in normal and diabetic rats. However, no difference was observed in the glycated albumin/nonglycated albumin clearance ratios (Cga/Calb) in normal and diabetic rats, respectively (2.18 +/- 0.39 vs 1.83 +/- 0.22, P greater than 0.05). The second technique measured the renal clearance of injected 125I-labelled glycated albumin and 125I-labelled albumin. The endogenous results were supported by the finding that 125I-labelled glycated albumin was cleared more rapidly than 125I-labelled albumin in normal (P less than 0.01) and diabetic (P less than 0.05) rats. The Cga/Calb ratio calculated for the radiolabelled albumins was 1.4 and 2.0 in normal and diabetic rats, respectively. This evidence suggests that nonenzymatic glycation of albumin increases its renal clearance to a similar degree in normal and diabetic rats

  5. Reliability of two different methods, whole body measurement and shoulder probe measurement, as judged from determinations of the renal clearance of orthoiodine hippuric acid. Methodenvergleich von Ganzkoerper- und Schultersonden-Messtechnik bei der nuklearmedizinischen Nierenclearance-Bestimmung mit Ortho-Jod-Hippursaeure

    Energy Technology Data Exchange (ETDEWEB)

    Roth, A

    1983-05-06

    This retrospective study was based on 1300 patients subjected to a series of radiopharmaceutical renal function studies, during which parallel determinations of the renal clearance rate were carried out using whole body measurements and shoulder probe measurements. It was the aim of this analysis to assess the reliability of shoulder probe measurements as compared to that of whole body measurements as well as their suitability for the diagnosis of postural perfusion disorders associated with nephroptosis and to define the generally acceptable normal ranges of the clearance of ortho-iodine hippuric acid on the basis of age and sex groups. As long as the values measured remained within normal limits, no major differences were discernable between the two methods. In reduced renal function, however, the shoulder probe measurements were biassed in a consistent way and tended to an overestimation of the renal performance that was proportionate to the degree of insufficiency. The intra-assay variations observed for the two methods did not differ from each other at a statistically significant level. The systematic error seen in connection with the shoulder probe measurements can in fact be easily eliminated. This method also offers the advantage of greater simplicity and can be carried out with the patient being in an upright position. Its suitability for the detection of postural perfusion disorders still remains to be proven in further studies. The results of the study are of clinical relevance inasfar as it was possible to determine lower limits of OJH clearance for the individual age and sex groups.

  6. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    OpenAIRE

    Pickering, John W; Frampton, Christopher M; Walker, Robert J; Shaw, Geoffrey M; Endre, Zolt?n H

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 h...

  7. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure.

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D; Macdougall, Iain C; Ponikowski, Piotr; Lainscak, Mitja

    2015-12-01

    To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P=0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P=0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number: NCT01829880.

  8. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D.; Macdougall, Iain C.; Ponikowski, Piotr; Lainscak, Mitja

    2015-01-01

    Aim To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Methods Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Results Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P = 0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P = 0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Conclusions Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number NCT01829880 PMID:26718759

  9. Comparison of conventional renal clearance values with differently evaluated results of radioisotope nephrography

    International Nuclear Information System (INIS)

    Grebe, S.F.; Weise, M.; Berghaeuser, H.; Faengewisch, G.L.; Temme, H.

    1981-01-01

    81 patients with renal anormalities or renal disorders of different genesis and severity with and without restricted renal functions were investigated by means of the classical PAH- and inulin-clearance. Furthermore a radioisotope nephrography was carried out after application of I 131-Hippuran followed by Cr 51-EDTA. In addition the activity reduction was measured above the shoulder, as well as the activity in serum samples and urine samples gained 30 min after application. A comparison of the clearance values found with those of conventional clearance resulted in poor correlation for I 131-Hippuran (r = 0.54) and no correlation for Cr 51-EDTA. Of the many parameters of the radioisotope nephrogram curves only the following are able to give sufficient quantitative functional results: The parameters connected with the rise of the curve between the 48sup(rh) and 120sup(rh) s and those connected with the slope of the secant. This is also true for the value of activity measured in the urine. (orig.) [de

  10. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  11. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  12. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  13. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  14. Augmented Renal Clearance in Critical Illness: An Important Consideration in Drug Dosing

    Directory of Open Access Journals (Sweden)

    Sherif Hanafy Mahmoud

    2017-09-01

    Full Text Available Augmented renal clearance (ARC is a manifestation of enhanced renal function seen in critically ill patients. The use of regular unadjusted doses of renally eliminated drugs in patients with ARC might lead to therapy failure. The purpose of this scoping review was to provide and up-to-date summary of the available evidence pertaining to the phenomenon of ARC. A literature search of databases of available evidence in humans, with no language restriction, was conducted. Databases searched were MEDLINE (1946 to April 2017, EMBASE (1974 to April 2017 and the Cochrane Library (1999 to April 2017. A total of 57 records were included in the present review: 39 observational studies (25 prospective, 14 retrospective, 6 case reports/series and 12 conference abstracts. ARC has been reported to range from 14–80%. ARC is currently defined as an increased creatinine clearance of greater than 130 mL/min/1.73 m2 best measured by 8–24 h urine collection. Patients exhibiting ARC tend to be younger (<50 years old, of male gender, had a recent history of trauma, and had lower critical illness severity scores. Numerous studies have reported antimicrobials treatment failures when using standard dosing regimens in patients with ARC. In conclusion, ARC is an important phenomenon that might have significant impact on outcome in critically ill patients. Identifying patients at risk, using higher doses of renally eliminated drugs or use of non-renally eliminated alternatives might need to be considered in ICU patients with ARC. More research is needed to solidify dosing recommendations of various drugs in patients with ARC.

  15. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  16. THE COMPARATIVE ANALYSIS OF RENAL FUNCTION IN LIVER DISEASES USING COCKCROFT-GAULT FORMULAE AND CREATININE CLEARANCE

    Directory of Open Access Journals (Sweden)

    Karem Ravi Teja

    2018-01-01

    Full Text Available BACKGROUND Kidney dysfunction in liver disease can be due to different aetiologies and can have diverse manifestations. Most of the abnormalities of kidney function in cirrhosis are of functional origin namely, sodium retention, impaired free water excretion and renal vasoconstriction with decrease in renal perfusion and glomerular filtration rate. Renal dysfunction in chronic liver disease usually follows a progressive course- the final phase being Hepatorenal Syndrome (HRS. MATERIALS AND METHODS This study included patients with chronic liver disease being treated as inpatients in the Department of General Medicine, Konaseema Institute of Medical Sciences, Amalapuram. Evidence for chronic liver disease being defined by a compatible clinical profile (signs of liver cell failure or reduced liver span along with biochemical (altered liver function tests, reversal of albuminglobulin ratio or sonographic evidence (altered echotexture of liver or tissue diagnosis (positive liver biopsy for cirrhosis. RESULTS Eighteen percent, i.e. 5 out of the 28 patients with creatinine clearance more than 60 mL/minute by Cockcroft-Gault formula were found to have creatinine clearance values less than 40 mL/minute when done by timed urine collection P value calculated was found to be less than 0.0001, which is statistically significant. CONCLUSION In chronic liver disease, serum creatinine alone is not a reliable marker to assess renal dysfunction. Calculating creatinine clearance by using Cockcroft-Gault formula overestimates renal function in cirrhotics. Creatinine clearance measured by timed urine collections should be done routinely to assess renal reserve in advanced liver disease. Alcoholism appears to have adverse effect on renal function when compared with other aetiologies of cirrhosis.

  17. Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

    International Nuclear Information System (INIS)

    Hackstein, N.; Puille, M.F.; Bak, Benjamin H.; Scharwat, Oliver; Rau, W.S.

    2001-01-01

    Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r=0.78 with Cl (CT) [ml/min]=22.2+1.03 * Cl (serum), n=24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r=0.89 with rkf(CT)[%]=18.6+0.58 * rkf(scintigraphy), n=29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy

  18. Use of specific radioimmunoassays to determine the renal clearance rates of estrone and 17. beta. -estradiol during the menstrual cycle. [Tritium tracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wright, K.; Collins, D.C.; Preedy, J.R.K.

    1978-11-01

    Specific RIAs requiring ether extraction only were established for estrone and 17..beta..-estradiol both in plasma and in urine from the nonpregnant female. These assays were used to measure the renal clearance rates of estrone and of 17..beta..-estradiol in eight ambulatory women in the follicular and in the luteal phases of the menstrual cycle. The mean (+-SE) for the renal clearance rate of estrone was 0.71 +- 0.058 ml/min in the follicular phase and 1.26 +- 0.35 ml/min in the luteal phase. The mean (+-SE) renal clearance rate of 17..beta..-estradiol was 0.44 +- 0.055 ml/min in the follicular phase and 0.29 +- 0.043 ml/min in the luteal phase. There was no significant difference in the renal clearance rates of either estrone or of 17..beta..-estradiol between the follicular and luteal phases of the cycle. The renal clearances of estrone and 17..beta..-estradiol were highly correlated (r = 0.84; P < 0.01). The renal clearance rate of estrone was significantly greater than that of 17..beta..-estradiol in both phases of the cycle (P < 0.01).

  19. Lithium clearance and renal tubular sodium handling during acute and long-term nifedipine treatment in essential hypertension

    DEFF Research Database (Denmark)

    Bruun, N E; Ibsen, H; Skøtt, P

    1988-01-01

    1. In two separate studies the lithium clearance method was used to evaluate the influence of acute and long-term nifedipine treatment on renal tubular sodium reabsorption. 2. In the acute study, after a 4 week placebo period two doses of 20 mg of nifedipine decreased supine blood pressure from 155...... were also unchanged, as were potassium clearance, urine flow and body weight. 3. In the long-term study, lithium clearance, glomerular filtration rate, sodium clearance, potassium clearance, urine flow and body fluid volumes were measured after a 4 weeks placebo period and after 6 and 12 weeks....../101 (20.6/13.5) +/- 11/4 (1.5/0.5) to 139/88 (18.5/11.7) +/- 16/9 (2.1/1.2) mmHg (kPa) (means +/- SD; P less than 0.01). Lithium clearance, glomerular filtration rate and sodium clearance did not change. Therefore the calculated values of absolute proximal and absolute distal sodium reabsorption rates...

  20. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  1. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, N V; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium......-induced changes in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  2. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium...... in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies, increase baseline......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  3. Towards a system-based pharmacology approach to predict developmental changes in renal drug clearance in children

    NARCIS (Netherlands)

    De Cock, Roosmarijn Frieda Wilfried

    2014-01-01

    Renal clearance is responsible for the elimination of a large number of water-soluble drugs and metabolites and is therefore of large importance when characterizing the pharmacokinetics of drugs. Renal clearance includes glomerular filtration, tubular secretion and reabsorption and each of these

  4. Frequency and factors effecting non clearance of lower pole renal stones

    International Nuclear Information System (INIS)

    Ullah, A.; Zubair, M.; Khan, N.; Malik, A.

    2015-01-01

    Renal stone disease is a major health hazard in Pakistan and extra-corporeal shockwave lithotripsy is one of comprehensive method used to treat these stones. The aim of this study is to determine the frequency of factors affecting the non-clearance of stone fragments of lower pole renal stone after extra corporeal shockwave lithotripsy. The study was done with the objective to determine the frequency the spatial anatomical factors which can influence the non-clearance of lower pole stone fragments after ESWL. Methods: One and nineteen (119) patients with lower pole renal stone less than 10 mm were subjected to maximum 3 sessions of extracorporeal shock wave lithotripsy. KUB radiographs, ultrasonography and intravenous urography were used as investigative tools for lower pole renal calyceal anatomy. X ray KUB and ultrasound were done after a week for clearance. Data was analysed with the help of SPSS version 10.0 and presented in the forms of tables and graphs. Results: There were 77 (64.71%) males and 42 (35.29%) females. Infundibulo-pelvic angle (IPA)>40 degree was present in 93 (78.15%), Infundibular length (IL) <22 mm in 107 (89.92%) and Infundibular width (IW) >4 mm was present in 100 (84.03%) patients. The frequency of stone non clearance was noted in 31 (26.05%). Infundibulo-pelvic angle (IPA)>40 degree (p=0.000), Infundibular length (IL)<22 mm (p=0.001) and Infundibular width (IW)>4 mm (p=0.046) were significant variables affecting stone clearance. Conclusion: The frequency of non-clearance of lower calyx of kidney stone is 26.05%. The clearance of fragments of the lower calyx kidney stones is affected by three spatial anatomical factors, i.e., Infundibulopelvic angle, Infundibular width and infundibular length. (author)

  5. Influence of Pelvicaliceal Anatomy on Stone Clearance After Flexible Ureteroscopy and Holmium Laser Lithotripsy for Large Renal Stones.

    Science.gov (United States)

    Inoue, Takaaki; Murota, Takashi; Okada, Shinsuke; Hamamoto, Shuzo; Muguruma, Kouei; Kinoshita, Hidefumi; Matsuda, Tadashi

    2015-09-01

    This study was performed to evaluate the impact of pelvicaliceal anatomy on stone clearance in patients with remnant fragments in the lower pole after flexible ureteroscopy and holmium laser lithotripsy (fURSL) for renal stones >15 mm. This retrospective study included 67 patients with radiopaque residual fragments (>2 mm) in the lower pole after fURSL for large renal stones (>15 mm). The preoperative infundibular length (IL), infundibular width (IW), infundibulopelvic angle (IPA), and caliceal pelvic height (CPH) were measured using intravenous urography. Multivariate analysis was performed to determine whether any of these measurements affected stone clearance. Of the 67 patients, 55 (82.1%) were stone free (SF) 3 months after fURSL. The anatomic factors significantly favorable for an SF status were a short IL, broad IW, wide IPA, and low CPH. On multivariate analysis, the IPA had a significant influence on an SF status after fURSL (p=0.010). An IPA renal stones according to our multivariate analysis. Additional studies are required to further evaluate the characteristics of the pelvicaliceal anatomy influencing stone clearance.

  6. High Phenobarbital Clearance During Continuous Renal Replacement Therapy

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-01-01

    Abstract Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring. A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure. Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus. The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed. Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring. PMID:25101986

  7. Effects of hyperventilation and hypocapnic/normocapnic hypoxemia on renal function and lithium clearance in humans

    DEFF Research Database (Denmark)

    Christensen, H; Klausen, T; Fogh-Andersen, N

    1998-01-01

    Using the renal clearance of lithium as an index of proximal tubular outflow, this study tested the hypothesis that acute hypocapnic hypoxemia decreases proximal tubular reabsorption to the same extent as hypocapnic normoxemia (hyperventilation) and that this response is blunted during normocapnic...

  8. [The equivalent renal urea clearance. Its relationship with mortality in chronic hemodialysed patients].

    Science.gov (United States)

    Barreneche, M; Carreras, R; Leanza, H J; Najún Zarazaga, C J

    1999-01-01

    The Equivalent Renal Urea Clearance (EKR) integrates the residual renal function (KR) and the dialysis dose (Kt/V). The present study was performed with these objectives: to calculate EKR in our hemodialysis (HD) patients during a three year follow up, to define its relationship with mortality and to compare its importance as a risk factor among others and to calculate actuarial survival. We analyzed 267 chronic HD patients. We measured Kt/V single pool, TACu, albumin, creatinine, hemoglobin and HD time and we calculated KR, EKR, KRc and EKRc (the last two corrected for V* 401--to compare clearances of different size patients). The EKRc median was 14.20 ml/min and it was taken as cut off point. The mortality OR was 2.17. The multivariated analysis showed, as independent mortality predictors, the albumin (the most significant), the EKRc and the HD time. The actuarial survival of EKRc, Kt/V and albumin showed marked similarity of their curves. The significant differences between the predictor curves began on the 2nd year of HD, for albumin they began in levels lesser than 3.5 g/dl and higher than 3.4 g/dl. Therefore, we consider that the best advantage of EKRc, compared to other parameters derived from the urea kinetics model, was the possibility to valuate the weekly HD adequation (once, twice or three times a week) and this, depending on the KR and the Kt/V of each HD treatment. Besides, the EKRc could also be used as adequacy criterion in CAPD considering daily Kt/V so that we could employ EKRc as adequacy parameter for both replacement therapies.

  9. Significance of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy in nonobstructive isolated renal pelvic stones.

    Science.gov (United States)

    Sozen, Sinan; Kupeli, Bora; Acar, Cenk; Gurocak, Serhat; Karaoglan, Ustunol; Bozkirli, Ibrahim

    2008-05-01

    To investigate the probable effect of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy (SWL) in patients with nonobstructive renal pelvic stones. The clinical records of patients with isolated renal pelvic stones who underwent SWL between 1996 and 2005 were reviewed. After excluding patients with obstruction leading to dilatation, major anatomic abnormalities, noncalcium stones, metabolic abnormalities, history of recurrent stone disease, multiple stones, and previous renal surgery, 153 patients were enrolled in the study. Lower pole infundibulopelvic angle (IPA) and infundibular length and width were measured from intravenous urography. Patients were classified into three groups according to stone burden (group 1, renal pelvis, and both in 50 (32.6%), 29 (18.9%), and 8 (5.2%) patients, respectively. There was no statistically significant difference in pelvicaliceal anatomic features except narrower IPA (P=0.02) in group 1 patients with residual stones. The falling of stone fragments to the lower calix in spite of the ureter whether clinically significant or not after SWL of pelvic stones initially seems to be related to stone burden rather than lower caliceal anatomy. However, existence of a more narrow IPA in group 1 patients with residual fragments led us to believe that lower-pole IPA can play a role in stone clearance, especially for smaller stones, probably because of smaller residual fragment size or the more mobile nature of the primary stone.

  10. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  11. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  12. Endogenous versus exogenous lithium clearance for evaluation of dopamine-induced changes in renal tubular function

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Fogh-Andersen, N; Strandgaard, S

    1996-01-01

    1. The present randomized, double-blind cross-over study compared endogenous and exogenous lithium clearance (CLi) for estimation of the effect of dopamine on tubular sodium reabsorption. Twelve normal, salt-repleted male subjects were investigated on three different occasions with either placebo...... or 450 mg or 600 mg of lithium given in random order at 22.00 hours. After an overnight fast, renal clearance studies were performed during a 1 h baseline period and subsequently during the second hour of an infusion of 3 micrograms min-1 kg-1 of dopamine. 2. Baseline values of endogenous CLi.......3-31.0)% (P lithium increased the baseline sodium clearance (CNa), but glomerular filtration rate and urine flow rate remained unchanged. 3. Dopamine increased CNa to similar values on the three study days. CLi increased to 40.9 (35.5-46.5) ml/min (endogenous lithium, P

  13. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F

    1996-01-01

    Renal blood flow (RBF) was measured in 9 patients with chronic impaired kidney function using MR velocity mapping and compared to PAH clearance and 99mTc-DTPA scintigraphy. An image plane suitable for flow measurement perpendicular to the renal arteries was chosen from 2-dimensional MR angiography....... MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated...... by 99mTc-DTPA scintigraphy. A reduction of RBF was found, and there was a significant correlation between PAH clearance multiplied by 1/(1-hematocrit) and RBF determined by MR velocity mapping. Furthermore, a significant correlation between the distribution of renal function and the percent distribution...

  14. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  15. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  16. Longitudinal Associations among Renal Urea Clearance-Corrected Normalized Protein Catabolic Rate, Serum Albumin, and Mortality in Patients on Hemodialysis.

    Science.gov (United States)

    Eriguchi, Rieko; Obi, Yoshitsugu; Streja, Elani; Tortorici, Amanda R; Rhee, Connie M; Soohoo, Melissa; Kim, Taehee; Kovesdy, Csaba P; Kalantar-Zadeh, Kamyar

    2017-07-07

    There are inconsistent reports on the association of dietary protein intake with serum albumin and outcomes among patients on hemodialysis. Using a new normalized protein catabolic rate (nPCR) variable accounting for residual renal urea clearance, we hypothesized that higher baseline nPCR and rise in nPCR would be associated with higher serum albumin and better survival among incident hemodialysis patients. Among 36,757 incident hemodialysis patients in a large United States dialysis organization, we examined baseline and change in renal urea clearance-corrected nPCR as a protein intake surrogate and modeled their associations with serum albumin and mortality over 5 years (1/2007-12/2011). Median nPCRs with and without accounting for renal urea clearance at baseline were 0.94 and 0.78 g/kg per day, respectively (median within-patient difference, 0.14 [interquartile range, 0.07-0.23] g/kg per day). During a median follow-up period of 1.4 years, 8481 deaths were observed. Baseline renal urea clearance-corrected nPCR was associated with higher serum albumin and lower mortality in the fully adjusted model ( P trend urea clearance-corrected nPCR during the first 6 months was also associated with attaining high serum albumin (≥3.8 g/dl) and lower mortality ( P trend urea clearance, higher levels of renal urea clearance-corrected nPCR consistently showed lower mortality risk. Among incident hemodialysis patients, higher dietary protein intake represented by nPCR and its changes over time appear to be associated with increased serum albumin levels and greater survival. nPCR may be underestimated when not accounting for renal urea clearance. Compared with the conventional nPCR, renal urea clearance-corrected nPCR may be a better marker of mortality. Copyright © 2017 by the American Society of Nephrology.

  17. A computer program for unilateral renal clearance calculation by a modified Oberhausen method

    International Nuclear Information System (INIS)

    Brueggemann, G.

    1980-01-01

    A FORTAN program is presented which, on the basis of data obtained with NUKLEOPAN M, calculates the glomerular filtration rate with sup(99m)Tc-DTPA, the unilateral effective renal plasma flow with 131 I-hippuran, and the parameters for describing the isotope rephrogram (ING) with 131 I-hippuran. The results are calculated fully automatically upon entry of the data, and the results are processed and printed out. The theoretical fundamentals of ING and whole-body clearance calculation are presented as well as the methods available for unilateral clearance calculation, and the FORTAN program is described in detail. The standard values of the method are documented, as well as a comparative gamma camera study of 48 patients in order to determine the accuracy of unilateral imaging with the NUKLEOPAN M instrument, a comparison of unilateral clearances by the Oberhausen and Taplin methods, and a comparison between 7/17' plasma clearance and whole-body clearance. Problems and findings of the method are discussed. (orig./MG) [de

  18. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  19. 99mTc-DMSA renal uptake in urological diseases measured from renal tomographic images using single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Oishi, Yukihiko; Tashiro, Kazuya; Kishimoto, Koichi; Wada, Tetsuro; Torii, Shinichiro; Yoshigoe, Fukuo; Machida, Toyohei; Yamada, Hideo; Toyama, Hinako.

    1987-01-01

    To determine renal function, 99m Tc-DMSA renal uptake was measured from renal tomographic images obtained by single photon emission computed tomography (SPECT). A total of 77 tests was conducted on 73 patients with various diseases in the kidneys and urinary tract to determine renal uptake. The correlation coefficient(r) between total renal volume and total renal uptake was 0.3509 and that between renal volume and uptake of 143 kidneys was 0.5433. In 62 patients whose creatinine clearance could be measured, the correlation coefficient between creatinine clearance and total renal volume was 0.2352, and that between creatinine clearance and total renal uptake was 0.8854, that is, creatinine clearance correlated well with renal uptake. Renal volume and uptake determined in 10 normal male and 10 normal female adults were 220 ml and 26.8 % for the right kidney and 239 ml and 27.6 % for the left kidney for the males and 206 ml and 26.4 % (right) and 237 ml and 27.9 % (left) for the females. This method, which requires no blood or urine collection, is very useful as an individual kidney function test to evaluate individual kidney function and to understand kidney function before and after operation in patients with renal and urinary diseases. (author)

  20. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  1. RENAL CLEARANCE AND URINARY EXCRETION OF KANAMYCIN IN DOMESTIC RUMINANT SPECIES

    Directory of Open Access Journals (Sweden)

    I. JAVED, Z. U. RAHMAN, F. H. KHAN, F. MUHAMMAD, Z. IQBAL AND B. ASLAM

    2006-01-01

    Full Text Available Species dependent geonetical differences in renal clearance and urinary excretion of kanamycin were investigated in adult female buffaloes, cows, sheep and goats. The drug was administered as a single intravenous dose (5 mg/kg b.wt. Blood and urine samples were collected at various time intervals after drug administration. The plasma and urine concentrations of the drug were determined using the microbiological assay. The mean (± SE values for endogenous creatinine clearance (an index of glomerular filtration rate were 0.77 ± 0.05, 0.49 ± 0.07, 0.81 ± 0.07 and 0.98 ± 0.13 ml/min.kg in buffaloes, cows, sheep and goats, respectively. Experiments regarding kidney handling of kanamycin in these ruminant species revealed respective values of renal clearance as 0.08 ± 0.01, 0.07 ± 0.01, 0.19 ± 0.02 and 0.23 ± 0.04 ml/min.kg. Besides glomerular filtration, kanamycin was reabsorbed from the renal tubules of all ruminant species and actively secreted into the renal tubules of buffaloes and goats. The cumulative percentages of intravenous dose of kanamycin excreted through urine during 12 hours in buffaloes, cows, sheep and goats were 4.31 ± 0.37, 2.53 ± 0.30, 11.0 ± 1.04 and 15.8 ± 2.22, respectively. This species variation in the percentage of urinary excretion in these domestic ruminants coincides with their respective glomerular filtration rates, being the highest in goats, lowest in cows and intermediate in sheep and buffaloes.

  2. Effects and outcome of Tamsulosin more than just stone clearance after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Qadri, S. S. U.; Khalid, S. E.; Mahmud, S. M.

    2014-01-01

    Objective: To determine the effect of Tamsulosin, as adjunctive medical therapy after Extracorporeal Shock Wave Lithotripsy for renal stones on rate of stone clearance, clearance time, pain intensity during stone clearance, steinstrasse formation and auxiliary surgical intervention required. Method: A prospective randomized controlled study was carried out in 120 patients who underwent ESWL for renal stones of 0.5-2.0 cm. They were randomized into study and control group in which Tamsulosin 0.4mg/day was given in former as an adjunctive medical therapy. All patients underwent ESWL every 2 weeks until complete stone clearance for 8 weeks. The parameters assessed were stone clearance, clearance time, pain intensity and effect on steinstrasse. Results: Of the 120 patients 60 were in each group. The stone clearance rate was greater in study than in control group, 58(96.7%) vs. 48(80%) respectively, (p<0.004). The mean stone clearance time was observed earlier in study group as compared to control group with significant statistical difference in stone size between 0.6-1.5 cm. The mean intensity of pain patients experienced according to Visual analogue scale (VAS) was significantly less in study group (p<0.002). The rate of steinstrasse formation was observed to be higher in control than in study group 15(25%) vs 6(10%) respectively(p<0.003), while its spontaneous clearance was higher in study group than in control group 83.3% vs 33.3% (p<0.03). Conclusion: Tamsulosin significantly increases stone clearance after shock wave lithotripsy for renal stones. It also appeared to facilitate earlier stone clearance, reduces severity of pain, reduces the incidence of steinstrasse formation and tends to facilitate its spontaneous clearance. (author)

  3. Impact on creatinine renal clearance by the interplay of multiple renal transporters: a case study with INCB039110.

    Science.gov (United States)

    Zhang, Yan; Warren, Mark S; Zhang, Xuexiang; Diamond, Sharon; Williams, Bill; Punwani, Naresh; Huang, Jane; Huang, Yong; Yeleswaram, Swamy

    2015-04-01

    Serum creatinine is commonly used as a marker of renal function, but increases in serum creatinine might not represent changes in glomerular filtration rate (GFR). INCB039110 (2-(3-(4-(7H-pyrrolo[2,3-day]pyrimidin-4-yl)-1H-pyrazol-1-yl)-1-(1-(3-fluoro-2-(trifluoromethyl)isonicotinoyl)piperidin-4-yl)azetidin-3-yl)acetonitrile) is an inhibitor of the Janus kinases (JAKs) with selectivity for JAK1. In a phase 1 study, a modest and reversible increase in serum creatinine was observed after treatment with INCB039110. However, a dedicated renal function study with INCB039110, assessed by iohexol plasma clearance, conducted in healthy volunteers indicated no change in GFR. In vitro studies were therefore conducted to investigate the interaction of INCB039110 with five transporters that are likely involved in the renal clearance of creatinine. Cell systems expressing individual or multiple transporters were used, including a novel quintuple-transporter model OAT2/OCT2/OCT3/MATE1/MATE2-K. INCB039110 potently inhibited OCT2-mediated uptake of creatinine as well as MATE1-/MATE2-K-mediated efflux of creatinine. Given the interactions of INCB039110 with multiple transporters affecting creatinine uptake and efflux, an integrated system expressing all five transporters was sought; in that system, INCB039110 caused a dose-dependent decrease in transcellular transport of creatinine with weaker net inhibition compared with the effects on individual transporters. In summary, a molecular mechanism for the increase in serum creatinine by INCB039110 has been established. These studies also underline the limitations of using serum creatinine as a marker of renal function. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  4. Passing through the renal clearance barrier: toward ultrasmall sizes with stable ligands for potential clinical applications

    Directory of Open Access Journals (Sweden)

    Zhang XD

    2014-04-01

    Full Text Available Xiao-Dong Zhang,1 Jiang Yang,2 Sha-Sha Song,1 Wei Long,1 Jie Chen,1 Xiu Shen,1 Hao Wang,1 Yuan-Ming Sun,1 Pei-Xun Liu,1 Saijun Fan11Tianjin Key Laboratory of Molecular Nuclear Medicine, Institute of Radiation Medicine, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, People's Republic of China; 2Department of Biological Systems Engineering, University of Wisconsin-Madison, Madison, WI, USAAbstract: The use of nanoparticles holds promise for medical applications, such as X-ray imaging, photothermal therapy and radiotherapy. However, the in vivo toxicity of inorganic nanoparticles raises some concern regarding undesirable side effects which prevent their further medical application. Ultrasmall sub-5.5 nm particles can pass through the barrier for renal clearance, minimizing their toxicity. In this letter we address some recent interesting work regarding in vivo toxicity and renal clearance, and discuss the possible strategy of utilizing ultrasmall nanomaterials. We propose that small hydrodynamic sized nanoclusters can achieve both nontoxic and therapeutic clinical features.Keywords: in vivo clearance, gold nanoparticles, small size

  5. Perspectives on hypertension outcomes after single-stage clearance of a complete staghorn renal calculus

    Directory of Open Access Journals (Sweden)

    Ranjit Chaudhary

    2017-01-01

    Full Text Available A 55-year-old male presented, in June 2013, with left flank pain. Investigations revealed a complete staghorn stone. He had undergone two sittings of extracorporeal shock wave lithotripsy (ESWL in 2008 for left renal stone. One year subsequent to this, he was diagnosed with hypertension and diabetes. The management of complete staghorn stones in a single sitting is a difficult proposition. Percutaneous nephrolithotomy (PCNL is the gold standard to manage such stones. The patient was subjected to PCNL, and complete clearance was achieved in one sitting. On one-year follow-up, there was a significant reduction in blood pressure (BP and better glycemic control. Although there are several reports where hypertension has been reported after multiple sittings of ESWL, whether ESWL contributed to the genesis of hypertension and diabetes in this patient or it was simply incidental, cannot be stated with certainty. There was a significant reduction in the BP after complete stone removal, but there is uncertainty over the effect of total clearance of renal stones on hypertension, and we need to await the results of more controlled trials studying this phenomenon. A better glycemic control was perhaps achieved secondary to the eradication of recurrent urinary tract infections due to complete stone clearance.

  6. Augmented renal clearance is not a risk factor for mortality in Enterobacteriaceae bloodstream infections treated with appropriate empiric antimicrobials.

    Science.gov (United States)

    Burnham, Jason P; Micek, Scott T; Kollef, Marin H

    2017-01-01

    The main objective of the study was to assess whether augmented renal clearance was a risk factor for mortality in a cohort of patients with Enterobacteriaceae sepsis, severe sepsis, or septic shock that all received appropriate antimicrobial therapy within 12 hours. Using a retrospective cohort from Barnes-Jewish Hospital, a 1,250-bed teaching hospital, we collected data on individuals with Enterobacteriaceae sepsis, severe sepsis, and septic shock who received appropriate initial antimicrobial therapy between June 2009 and December 2013. Clinical outcomes were compared according to renal clearance, as assessed by Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formulas, sepsis classification, demographics, severity of illness, and comorbidities. We identified 510 patients with Enterobacteriaceae bacteremia and sepsis, severe sepsis, or septic shock. Sixty-seven patients (13.1%) were nonsurvivors. Augmented renal clearance was uncommon (5.1% of patients by MDRD and 3.0% by CKD-EPI) and was not associated with increased mortality. Our results are limited by the absence of prospective determination of augmented renal clearance. However, in this small cohort, augmented renal clearance as assessed by MDRD and CKD-EPI does not seem to be a risk factor for mortality in patients with Enterobacteriaceae sepsis. Future studies should assess this finding prospectively.

  7. Avaliação renal de hipertensos pela clearance de creatinina num centro de saúde de Teresina-PI, Brasil Evaluación renal de hipertensos en el aclaramiento de creatinina en un centro sanitario de Teresina- PI, Brasil Evaluation of renal hypertensive by creatinine clearance in a health center in Teresina-pi, Brazil

    Directory of Open Access Journals (Sweden)

    Dinah Sá Rezende Neta

    2012-03-01

    hypertension by means of creatinine clearance, starting with measurement of serum creatinine. The study had a quantitative approach, developed at Porto Alegre Health Center. Data collection was carried out in nursing consultations using serum creatinine measurements. After the calculation of creatinine clearance utilizing the Cockcroft-Gault equation, patients were classified in one of the six phases of chronic renal disorder. The results revealed that 74% of the sample had renal damage, which shows how important is the periodic assessment of renal function of patients with hypertension so that they can be monitored with regard to the progression of their chronic renal disorder.

  8. PAH clearance after renal ischemia and reperfusion is a function of impaired expression of basolateral Oat1 and Oat3

    OpenAIRE

    Bischoff, Ariane; Bucher, Michael; Gekle, Michael; Sauvant, Christoph

    2014-01-01

    Abstract Determination of renal plasma flow (RPF) by para‐aminohippurate (PAH) clearance leads to gross underestimation of this respective parameter due to impaired renal extraction of PAH after renal ischemia and reperfusion injury. However, no mechanistic explanation for this phenomenon is available. Based on our own previous studies we hypothesized that this may be due to impairment of expression of the basolateral rate limiting organic anion transporters Oat1 and Oat3. Thus, we investigat...

  9. Effect of metabolic acidosis on renal tubular sodium handling in rats as determined by lithium clearance

    Directory of Open Access Journals (Sweden)

    Menegon L.F.

    1998-01-01

    Full Text Available Systemic metabolic acidosis is known to cause a decrease in salt and water reabsorption by the kidney. We have used renal lithium clearance to investigate the effect of chronic, NH4Cl-induced metabolic acidosis on the renal handling of Na+ in male Wistar-Hannover rats (200-250 g. Chronic acidosis (pH 7.16 ± 0.13 caused a sustained increase in renal fractional Na+ excretion (267.9 ± 36.4%, accompanied by an increase in fractional proximal (113.3 ± 3.6% and post-proximal (179.7 ± 20.2% Na+ and urinary K+ (163.4 ± 5.6% excretion when compared to control and pair-fed rats. These differences occurred in spite of an unchanged creatinine clearance and Na+ filtered load. A lower final body weight was observed in the acidotic (232 ± 4.6 g and pair-fed (225 ± 3.6 g rats compared to the controls (258 ± 3.7 g. In contrast, there was a significant increase in the kidney weights of acidotic rats (1.73 ± 0.05 g compared to the other experimental groups (control, 1.46 ± 0.05 g; pair-fed, 1.4 ± 0.05 g. We suggest that altered renal Na+ and K+ handling in acidotic rats may result from a reciprocal relationship between the level of metabolism in renal tubules and ion transport.

  10. Megalin and cubilin are endocytic receptors involved in renal clearance of hemoglobin

    DEFF Research Database (Denmark)

    Gburek, Jakub; Verroust, Pierre J; Willnow, Thomas E

    2002-01-01

    -Sepharose affinity chromatography of solubilized renal brush-border membranes. Apparent dissociation constants of 1.7 microM for megalin and 4.1 microM for cubilin were determined by surface plasmon resonance analysis. The binding was calcium dependent in both cases. Uptake of fluorescence-labeled hemoglobin by BN......The kidney is the main site of hemoglobin clearance and degradation in conditions of severe hemolysis. Herein it is reported that megalin and cubilin, two epithelial endocytic receptors, mediate the uptake of hemoglobin in renal proximal tubules. Both receptors were purified by use of hemoglobin...... not affect the uptake. By use of immunohistochemistry, it was demonstrated that uptake of hemoglobin in proximal tubules of rat, mouse, and dog kidneys occurs under physiologic conditions. Studies on normal and megalin knockout mouse kidney sections showed that megalin is responsible for physiologic...

  11. TGF-beta1 immunohistochemistry and promoter methylation in chronic renal failure rats treated with Uremic Clearance Granules.

    Directory of Open Access Journals (Sweden)

    Cheng-Bin Chen

    2010-08-01

    Full Text Available The aim of the study was the explain the mechanism related to therapeutic effects of Uremic Clearance Granules (Niaoduqing Keli in Chinese on adenine-induced Chronic Renal Failure in rats. Thirty 8-week-old male Wistar rats were selected and randomly divided in to 3 groups: Normal Control Group (NCGconsisted of 10 rats, Chronic Renal Failure Pathological Control Group (PCG 10 rats, and Uremic Clearance Granules Treatment Group (UCG 10 rats. Each rat in PCG and UCG was fed with adenine-enriched diets, containing 10 g adenine per kg food for 6 weeks. After fed with adenine, each rat in UCG was administered orally with 2 ml solution of Uremic Clearance Granules for 6 weeks. The concentration of Uremic Clearance Granules solution was 0.42 g/ml which was 10 times of human. On days 42 and 84, the serum levels of creatinine, Blood Urea Nitrogen and homocysteine were determined. The methylation of TGFbeta1 promoter was tested by methylation-specific PCR. TGF-beta1 mRNA and protein expression in rat renal cortex were analyzed by real-time RT-PCR and Immunohistochemistry. (1 Experimented on model of Chronic Renal Failure in rats, the preparation was proved to be able to reduce serum creatinine, Blood Urea Nitrogen, and homocysteine (p<0.05, improve renal function. (2 The expression of TGF-beta1 in mRNA and protein level were down-regulated. (3 TGF-beta1 promoter was demethylated at some loci in PCG, and was recovered in UCG. After treatment with Uremic Clearance Granules, the Chronic Renal Failure Wistar rat's kidney function was recovered. The recovery may be result of the remethylation of TGF-beta1 promoter and then lead to TGF-beta1 be transcripted and translated normally. The experimental study explain the molecular mechanism by which Uremic Clearance Granules treat Chronic Renal Failure.

  12. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  13. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  14. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  15. Diagnostic value of renal clearance techniques using iodo-hippuran /sup 131/I and /sup 99m/-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Hoer, G [Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

    1976-01-01

    Methods and clinical indications of divided renal clearance determination using /sup 131/I-hippuran are presented and their value as a diagnostic tool in urology is shown by two case reports. For quantitative assessment of renal function we prefer the whole body clearance (with partial shielding of kidneys and bladder) which obviates the necessity of the theoretical assumption of compartmental distribution of radiopharmaceuticals. Using simplified clearance techniques only based on analysis of plasma disappearance curves (slope clearance one- and two-compartment model), clinically useful results are also obtainable, especially in follow up studies. The evaluation of tubular and glomerular kidney function by simultaneous application of /sup 131/I-hippuran and sup(99m)Tc-DTPA is suitable for estimation of filtration fraction in patients with urological and nephrological diseases. Even with regard to therapy and follow up studies of urinary tract tuberculosis, remarkable dignostic informations may be achieved.

  16. Measurement of renal function with /sup 111/In-DTPA in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Saha, G B [Arkansas Univ., Little Rock (USA). Medical Center; Farrer, P A

    1977-07-01

    The renal clearances of /sup 111/In-DTPA were measured and compared with those of /sup 125/I-iothalamate in dogs using three methods: (a) constant infusion method, (b) single injection UV/P method, and (c) single injection slope method. The renal clearances of /sup 111/In-DTPA were on the average 9% higher than those of /sup 125/I-iothalamate. Its urinary excretion was approximately 50% at 1 hr and about 80% at 4 hr, and biliary excretion was negligible. Sequential scintiphotography of the renal system in dogs revealed the flow of the tracer through the kidneys, and excretion into the ureter and bladder.

  17. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  18. Rapid blood clearance and lack of long-term renal toxicity of 177Lu-DOTATATE enables shortening of renoprotective amino acid infusion

    International Nuclear Information System (INIS)

    Kashyap, Raghava; Eu, Peter; Jackson, Price; Hofman, Michael S.; Hicks, Rodney J.; Beauregard, Jean-Mathieu; Zannino, Diana

    2013-01-01

    The aim of the study was to investigate the feasibility of shortening the recommended 4-h renoprotective amino acid infusion in patients receiving peptide receptor chemoradionuclide therapy (PRCRT) using radiosensitizing 5-fluorouracil. We evaluated the clearance of radiopeptide from the blood, long-term nephrotoxicity in patients undergoing PRCRT with the conventional 4-h amino acid infusion and renal uptake in patients receiving an abbreviated infusion. The whole-blood clearance of 177 Lu-DOTA-octreotate (LuTate) was measured in 13 patients receiving PRCRT. A retrospective analysis of short-term and long-term changes in glomerular filtration rate (GFR) in 96 consecutive patients receiving a 4-h infusion was performed. Renal LuTate retention estimated using quantitative SPECT/CT in 22 cycles delivered with a 2.5-h amino acid infusion was compared with that in 72 cycles with the 4-h infusion. LuTate demonstrated biexponential blood clearance with an initial clearance half-time of 21 min. Approximately 88 % of blood activity was cleared within 2 h. With the 4-h protocol, there was no significant change in GFR (1.2 ml/min mean increase from baseline; 95 % CI -6.9 to 4.4 ml/min) and no grade 3 or 4 nephrotoxicity at the end of induction PRCRT. The long-term decline in GFR after a median follow up of 22 months was 2.2 ml/min per year. There was no significant difference in the renal LuTate retention measured in patients receiving a 2.5-h amino acid infusion compared to those who had a 4-h infusion. The greatest renal exposure to circulating radiopeptide occurs in the first 1 - 2 h after injection. This, combined with the safety of LuTate PRCRT, allows consideration of an abbreviated amino acid infusion, increasing patient convenience and reducing human resource allocation. (orig.)

  19. Rapid blood clearance and lack of long-term renal toxicity of {sup 177}Lu-DOTATATE enables shortening of renoprotective amino acid infusion

    Energy Technology Data Exchange (ETDEWEB)

    Kashyap, Raghava; Eu, Peter [Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Jackson, Price [Peter MacCallum Cancer Centre, Department of Physical Sciences, Melbourne (Australia); Hofman, Michael S.; Hicks, Rodney J. [Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); The University of Melbourne, Departments of Medicine and Radiology, Melbourne (Australia); Beauregard, Jean-Mathieu [Universite Laval, Department of Radiology, Quebec City (Canada); Zannino, Diana [Peter MacCallum Cancer Centre, Department of Biostatistics and Clinical Trials, Melbourne (Australia)

    2013-12-15

    The aim of the study was to investigate the feasibility of shortening the recommended 4-h renoprotective amino acid infusion in patients receiving peptide receptor chemoradionuclide therapy (PRCRT) using radiosensitizing 5-fluorouracil. We evaluated the clearance of radiopeptide from the blood, long-term nephrotoxicity in patients undergoing PRCRT with the conventional 4-h amino acid infusion and renal uptake in patients receiving an abbreviated infusion. The whole-blood clearance of {sup 177}Lu-DOTA-octreotate (LuTate) was measured in 13 patients receiving PRCRT. A retrospective analysis of short-term and long-term changes in glomerular filtration rate (GFR) in 96 consecutive patients receiving a 4-h infusion was performed. Renal LuTate retention estimated using quantitative SPECT/CT in 22 cycles delivered with a 2.5-h amino acid infusion was compared with that in 72 cycles with the 4-h infusion. LuTate demonstrated biexponential blood clearance with an initial clearance half-time of 21 min. Approximately 88 % of blood activity was cleared within 2 h. With the 4-h protocol, there was no significant change in GFR (1.2 ml/min mean increase from baseline; 95 % CI -6.9 to 4.4 ml/min) and no grade 3 or 4 nephrotoxicity at the end of induction PRCRT. The long-term decline in GFR after a median follow up of 22 months was 2.2 ml/min per year. There was no significant difference in the renal LuTate retention measured in patients receiving a 2.5-h amino acid infusion compared to those who had a 4-h infusion. The greatest renal exposure to circulating radiopeptide occurs in the first 1 - 2 h after injection. This, combined with the safety of LuTate PRCRT, allows consideration of an abbreviated amino acid infusion, increasing patient convenience and reducing human resource allocation. (orig.)

  20. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  1. PAH clearance after renal ischemia and reperfusion is a function of impaired expression of basolateral Oat1 and Oat3.

    Science.gov (United States)

    Bischoff, Ariane; Bucher, Michael; Gekle, Michael; Sauvant, Christoph

    2014-02-01

    Determination of renal plasma flow (RPF) by para-aminohippurate (PAH) clearance leads to gross underestimation of this respective parameter due to impaired renal extraction of PAH after renal ischemia and reperfusion injury. However, no mechanistic explanation for this phenomenon is available. Based on our own previous studies we hypothesized that this may be due to impairment of expression of the basolateral rate limiting organic anion transporters Oat1 and Oat3. Thus, we investigated this phenomenon in a rat model of renal ischemia and reperfusion by determining PAH clearance, PAH extraction, PAH net secretion, and the expression of rOat1 and rOat3. PAH extraction was seriously impaired after ischemia and reperfusion which led to a threefold underestimation of RPF when PAH extraction ratio was not considered. PAH extraction directly correlated with the expression of basolateral Oat1 and Oat3. Tubular PAH secretion directly correlated with PAH extraction. Consequently, our data offer an explanation for impaired renal PAH extraction by reduced expression of the rate limiting basolateral organic anion transporters Oat1 and Oat3. Moreover, we show that determination of PAH net secretion is suitable to correct PAH clearance for impaired extraction after ischemia and reperfusion in order to get valid results for RPF.

  2. Improved interpretation of renal-vein-renin-ratio by simultaneous determination of renal 131I-hippuric-acid-clearance-ratio in patients with renovascular hypertension

    International Nuclear Information System (INIS)

    Helber, A.; Boenner, G.; Hummerich, W.; Wambach, G.; Meurer, K.A.; Dvorak, K.; Lent, V.; Zehle, A.; Kaufmann, W.; Koeln Univ.; Staedtisches Krankenhaus Koeln-Merheim; Staedtisches Krankenhaus Koeln-Merheim; Koeln Univ.

    1979-01-01

    In patients with unilateral vascular kidney disease and hypertension, ratio of renal-vein-renin was compared with 131 I-Hippuric-acid clearance and change in blood pressure during Saralasininfusion. The ratio of renal-vein-renin was positively correlated with the ratio in renal plasma flow between the kidneys in all patients studied. The ratio of renins therefore is a result of two factors: The difference in renin secretion and the difference in blood flow in the two kidneys. In patients with angiotensin independent hypertension renin-ratios up to 2.0 were found without relevance to elevated blood pressure. When the difference in renal blood flow between both kidneys was small, even a slight difference in renal vein renin indicated hypertension related to increased renin secretion. (orig./AJ) [de

  3. Comparison of glomerular filtration rates by dynamic renal scintigraphy and dual-plasma sample clearance method in diabetic nephropathy

    International Nuclear Information System (INIS)

    Xie Peng; Huang Jianmin; Pan Liping; Liu Xiaomei; Wei Lingge; Gao Jianqing

    2010-01-01

    Objective: To evaluate the accuracy of renal scintigraphy for the estimation of glomerular filtration rates (dGFR) in patients with diabetic nephropathy as compared to the conventional dual-plasma sample clearance method (pscGFR). Methods: Forty-six patients with diabetic nephropathy underwent both dynamic renal scintigraphy and dual-plasma sample measurement after 99 Tc m -DTPA injection. Paired student t-test and correlation analysis were performed to compare dGFR and pscGFR (normalized to body surface area, 1.73 m -2 ). Results: The mean dGFR was higher than mean pscGFR ((51.08±26.78)ml·min -1 vs (44.06±29.43)ml·min -1 , t=4.209, P=0.000). The dGFR correlated with pscGFR (r=0.923, P=0.000) linearly (regression equation: pscGFR=1.015 x dGFR -7.773, F=254.656, P=0.000). Conclusions: dGFR correlated well with pscGFR. Although it could not absolutely replace the latter in patients with diabetic nephropathy, dGFR could reasonably evaluate the filtration function for these patients. (authors)

  4. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  5. Usefulness of parametric renal clearance images in the assessment of basic risk factors for renalnal clearance images in the assessment of basic risk factors for renal scarring in children with recurrent urinary tract infections.

    Science.gov (United States)

    Pietrzak-Stelasiak, Ewa; Bieńkiewicz, Małgorzata; Woźnicki, Wojciech; Bubińska, Krystyna; Kowalewska-Pietrzak, Magdalena; Płachcińska, Anna; Kuśmierek, Jacek

    2017-01-01

    Clinically confirmed incidents of acute pyelonephritis (APN) following recurrent infections of urinary tract (UTI) form basic risk factors for renal scarring in children. Vesico-uretheral reflux (VUR) of higher grade is additional risk factor for this scarring. Opinions on diagnostic value of summed sequential images of renal uptake phase (SUM) of dynamic renal scintigraphy in detection of renal scars are diverse. However, several publications point to higher diagnostic efficacy of clearance parametric images (PAR) generated from this study. To establish a clinical value of parametric renal clearance images in detection of renal scarring. A prospective study was performed in a group of 91 children at the age of 4 to 18 years with recurrent UTI. Clinically documented incidents of APN were noted in 32 children: in 8 cases - one and in the remaining 24 - 2 to 5 (mean 3) incidents. In the remaining 59 patients only infections of the lower part of urinary tract were diagnosed. Static renal 99mTc-DMSA SPECT study and after 2-4 days dynamic renal studies (99mTc-EC) were performed in every patient not earlier than 6 months after the last documented incident of UTI. PAR images generated from a dynamic study by in-house developed software and SUM images were compared with a gold standard SPECT study. Percentages of children with detected renal scar(s) with SPECT and PAR methods amounted to 55% and 54%, respectively and were statistically significantly higher (p children with history of APN detected with SPECT and PAR methods were significantly more frequent than with infections of only lower part of urinary tract (72% vs. 46%; p = 0.017 and 69% vs. 46%; p = 0.036, respectively). A SUM method did not reveal statistically significant differences between frequencies of detection of scars in groups specified above - 38% vs. 27% (p = 0.31). Both SPECT and PAR methods showed also that frequencies of occurrence of renal scars in children with higher grades of VUR were higher than

  6. Renal radioisotope clearance in an unselected group of diabetics - a tool for the early recognition of diabetic nephropathy

    International Nuclear Information System (INIS)

    Doschek, D.; Wulf, R.; Krause, F.J.; Kreiskrankenhaus Albstadt

    1980-01-01

    Our study in unselected patients with diabetes was undertaken to determine the relation between glomerular filtration rate (GFR) and renal plasma flow (RPF) according to the patient's age. The diagnostic work-up was done with patients in unselected disease states because a classification of all systemic manifestations of the diabetes was not possible. The lack of selection may therefore reduce the value of our statistical results. From age 55 onwards, there was a reduction in GFR and, to a lesser extent, in PRF esceeding that which was age-dependent. It is, therefore, recommended to check the clearance in all patients with diabetes older than 55 years. The clearance with radioisotopically labeled substances, being a very sensitive method for the evaluation of restricted renal function, may permit an early recognition of diabetic nephropathy. (orig.) [de

  7. A comparison of analytic procedures for measurement of fractional dextran clearances

    NARCIS (Netherlands)

    Hemmelder, MH; de Jong, PE; de Zeeuw, D

    Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein

  8. Treatment of Moderate Sized Renal Pelvis Calculi: Stone Clearance Time Comparison of Extracorporeal Shock Wave Lithotripsy and Retrograde Intrarenal Surgery.

    Science.gov (United States)

    Ercil, Hakan; Alma, Ergun; Bas, Okan; Sener, Nevzat Can; Vuruskan, Ediz; Kuyucu, Faruk; Unal, Umut; Gören, Mehmet Resit; Evliyaoglu, Yalcin

    2016-03-05

    To compare the stone clearance times in patients undergoing extracorporeal shock wave lithotripsy (SWL) or retrograde intrarenal surgery (RIRS) for single radiopaque renal pelvis stones 10-20 mm in size. The results of this study may guide urologists and patients and aid in selecting the optimal preoperative treatment. Between January 2013 and February 2015, we conducted a retrospective study and collected data from 333 patients treated with SWL (n = 172) or RIRS (n = 161). We included successfully treated patients with a single radiopaque renal pelvis stone 10-20 mm in size to calculate stone clearance times. The average stone size for the SWL group was 14.62 ± 2.58 mm and 14.91 ± 2.92 mm for the RIRS group. The mean Hounsfield unit (HU) of the patients was 585.40 ± 158.39 HU in the SWL group and 567.74 ± 186.85 HU in the RIRS group. Following full fragmentation, the mean stone clearance time was 26.55 ± 9.71 days in the SWL group and 11.59 ± 7.01 days in the RIRS group (P < .001). One of the most overlooked parameters in urinary stone treatments is stone clearance. We believe this study will shed light for those who aim to conduct larger randomized prospective studies. .

  9. Clearance measurements as a tool for waste minimization during decommissioning

    International Nuclear Information System (INIS)

    Konneus, Patrick; Andersson, Veronica; Lindberg, Maria

    2012-01-01

    Clearance, exemption or free release of material from regulatory control are three ways of expressing the same thing, minimizing the amount of waste that needs disposal as radioactive waste and therefor preserving a repository as a national asset. Studsvik Nuclear has utilized the former full body measurement cell as a shielded compartment used for gamma spectroscopy measurements of materials that may be subject to clearance. The cell was moved from its original position by heavy lifting and transport, as it was transported in one piece weighing 53 tonnes. The facility has basically 4 parts, the cell in which the item is place, the rotating table that rotates the item to get the best possible measurement, the ISOCS that measure the gamma rays and the operator room from which the facility runs. The detector is a BEGe with a relative efficiency of 50 % and is provided by Canberra. Apex is used as software for acquisition, calibration and data storage. The cell can take Bergloefs boxes up to a volume of 1.2m 3 and a weight of 3 tonnes can be rotated on the table. Other standard geometries are drums of 100 or 200 liters. The shielding improves the background radiation to a level where a measurement time of only 1200 s for a standard object (100 L/200 L drum, Bergloefs box) is needed. This means a high daily capacity of measurements. During 2011 measurements have been done on several different materials and together with sampling for alpha emitting nuclides the material has been released from regulatory control and either recycled or disposed of in a standard landfill or a land fill for hazardous waste. The materials released are copper from cable shredding that was measured, samples and recycled about 14 tonnes, titanium tubes about 35 tonnes also recycled and fiberglass/epoxy that has been released for waste treatment in a non-radioactive treatment facility. Measurements have also been done of waste with complex geometries. (authors)

  10. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  11. Changes in glomerular filtration rate, lithium clearance and plasma protein clearances in the early phase after unilateral nephrectomy in living healthy renal transplant donors

    DEFF Research Database (Denmark)

    Strandgaard, S; Kamper, A; Skaarup, P

    1988-01-01

    1. Glomerular and tubular function was studied before and 2 months after unilateral nephrectomy in 14 healthy kidney donors by measurement of the clearances of 51Cr-labelled ethylenediaminetetra-acetate, lithium, beta 2-microglobulin, albumin and immunoglobulin G. 2. The glomerular filtration rat...

  12. Measurement of effective renal plasma flow in congestive heart failure

    International Nuclear Information System (INIS)

    Tauxe, W.N.; Dubovsky, E.V.; Mantle, J.A.; Dustan, H.P.; Logic, J.R.

    1981-01-01

    In the management of patients with congestive heart failure (CHF), it is often desirable to have precise knowledge of overall renal function, including the effective renal plasma flow (ERPF). It has long been recognized that ERPF is diminished in CHF. Since glomerular filtration rate is often decreased to a much lesser extent, other noninvasive procedures such as the measurement of creatinine clearances may not be entirely suitable. ERPF determination by the single plasma sampling (SPS) method affords a rapid, simple, noninvasive, and economical technique that is quite accurate and reproducible. A SPS method has been well-tested in patients following renal transplantation plus a wide variety of nephrological disorders. We have been concerned whether the SPS method would be valid in volume expanded patients. In 28 determinations of ERPF in patients with CHF, and in five patients who did not have CHF, we have found the SPS estimation of ERPF to yield results that are not clinically significantly different from those obtained by the detailed compartmental analysis method. The volumes of 131 I-orthoiodohippurate (OIH) distribution were found to be somewhat higher in CHF than in controls, but fractional rate constants were proportionately lower so that intercompartmental flow rates and OIH concentrations were not different from controls. Therefore, the SPS estimation of ERPF is valid in patients with CHF and may be useful in monitoring the renal effects of various hemodynamic and pharmacological interventions. (orig.)

  13. Demonstration of Adaptive Functional Differences Seen in Kidneys Accompanying a Nonfunctioning/Hypofunctioning Partner, using Camera Based Tc 99m MAG3 Clearance Measurement Technique

    Directory of Open Access Journals (Sweden)

    Burcu Esen Akkaş

    2012-08-01

    Full Text Available Objective: The aim of this study was to demonstrate the functional compensation that occurs in kidneys which accompany a partner with total or partial loss of renal functioning mass, using camera-based Tc 99m MAG3 clearance technique. Material and Methods: Eighty five patients (43M, 42F, age: 44.8±12.6, range: 18-77 years with normal serum creatinine levels and normal (renal function<30%, (n=24, group 3: bilateral normal kidneys (n=38. The measured camera based Tc 99m MAG3 clearances of normal kidneys in each group were compared. Results: Total Tc 99m MAG3 clearances (mL/min/1.73m 2 were significantly lower in group 1 and group 2 compared to group 3 (281.5±46, 260.5±61.7 and 316.1±84, respectively. Highest isolated Tc 99m MAG3 clearances among normal functioning kidneys were observed in group 1 (281.5±45.6 followed by group 2 (204.4±55 and group 3 (157.5±44. Moderate negative correlation was detected between the Tc99m MAG3 clearances of normal kidneys and contralateral renal function (r=-0.5, p<0.001. Conclusion: Normal kidneys can compensate for the loss of contralateral kidney function via increasing their clearances, which seems to be dependent on the residual function of their partner. Camera based Tc 99m MAG3 clearance measurement is an objective method to demonstrate compensatory differences in renal function seen between kidneys with contralateral normofunctioning, hypofunctioning and nonfunctioning partner. (MIRT 2012;21:56-62

  14. A gene-gene interaction between polymorphisms in the OCT2 and MATE1 genes influences the renal clearance of metformin

    DEFF Research Database (Denmark)

    Hougaard Christensen, Mette Marie; Pedersen, Rasmus Steen; Stage, Tore Bjerregaard

    2013-01-01

    The aim of this study was to determine the association between the renal clearance (CL(renal)) of metformin in healthy Caucasian volunteers and the single-nucleotide polymorphism (SNP) c.808G>T (rs316019) in OCT2 as well as the relevance of the gene-gene interactions between this SNP and (a) the ...

  15. Techniques for blade tip clearance measurements with capacitive probes

    Science.gov (United States)

    Steiner, Alexander

    2000-07-01

    This article presents a proven but advantageous concept for blade tip clearance evaluation in turbomachinery. The system is based on heavy duty probes and a high frequency (HF) and amplifying electronic unit followed by a signal processing unit. Measurements are taken under high temperature and other severe conditions such as ionization. Every single blade can be observed. The signals are digitally filtered and linearized in real time. The electronic set-up is highly integrated. Miniaturized versions of the electronic units exist. The small and robust units can be used in turbo engines in flight. With several probes at different angles in one radial plane further information is available. Shaft eccentricity or blade oscillations can be calculated.

  16. Radioisotopic measurement of glomerular filtration rate in severe chronic renal failure

    International Nuclear Information System (INIS)

    LaFrance, N.D.; Drew, H.H.; Walser, M.

    1988-01-01

    In order to determine the best method for routine measurement of glomerular filtration rate (GFR) in severe renal failure, we compared simultaneously the urinary clearances of [/sup 99m/Tc] diethylenetriaminepentaacetic acid (DTPA) (UD), [ 125 I]iothalamate (UI), 24-hr creatinine clearance (UC) and plasma clearance of [/sup 99m/Tc]DTPA (PD), based on three plasma samples. In 60 studies in 22 patients with serum creatinine values of 2 to 8 mg/dl, UD and UI were almost identical: UD = 0.358 +/- 0.976 UI +/- 0.87 ml/min, r = 0.990. However, PD overestimated UD by a large and variable extent: PD = 11.3 +/- 0.843 UD +/- 5.5 ml/min, r = 0.694, and was inconsistent in sequential measurements in individual patients. UC also overestimated urinary isotope clearance: UC = 4.2 + 0.95 UI +/- 3.9 ml/min, r = 0.865. Sequential measurements of GFR in five patients with severe but stable renal failure (mean GFR 5.9 ml/min) showed an average standard deviation of only 0.83 ml/min. Thus both UD and UI appear to be reliable and precise measures of GFR in severe renal failure

  17. Estimating glomerular filtration rate: Cockcroft-Gault and Modification of Diet in Renal Disease formulas compared to renal inulin clearance.

    NARCIS (Netherlands)

    Botev, R.; Mallie, J.P.; Couchoud, C.; Schuck, O.; Fauvel, J.P.; Wetzels, J.F.M.; Lee, N.; Santo, N.G. De; Cirillo, M.

    2009-01-01

    BACKGROUND AND OBJECTIVES: Evaluation of renal function by estimation of the glomerular filtration rate (GFR) is very important for the diagnosis and treatment of patients with chronic kidney disease (CKD). The Cockcroft-Gault (CG) and Modification of Diet in Renal Disease (MDRD) formulas are the

  18. Relationship between renal cortex and parenchyma thickness and renal function: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian; Jiang Xuexiang

    2006-01-01

    Objective: To study the relationship between renal morphology and renal function, and to assess the value of CT as a criterion to grade renal function. Methods: Enhancement CT were performed in 89 patients with no local renal disease whose split renal glomerular filtration rates (GFR) were measured by renal dynamic imaging with 99 Tc m -DTPA. The 178 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between three groups respect to the mean thickness of renal cortex and parenchyma were assessed by ANOVA. Using Pearson's correlation test, the correlation between the renal cortex, parenchyma thicknesses and renal GFR were examined. The value of CT in predicting renal function was assessed by using ROC analysis. Results: The renal cortex thicknesses of normal renal function, mild and severe renal impairment groups were (5.9±1.1), (4.6± 1.1), and (3.3±1.0) mm respectively, and the renal parenchyma thicknesses were (26.3±4.2), (21.3±4.6), (16.2±4.6) mm. There were significant differences of renal cortex, parenchyma thicknesses between 3 groups (cortex F=54.78, P<0.01; parenehyma F=43.90, P<0.01). The thicknesses of renal cortex (r=0.752, P<0.01), parenchyma (r=0.738, P<0.01) had positive linear correlation with renal function. ROC analysis of the renal cortex thicknesses measured by CT in predicting mild and severe renal impairment showed that the Az was 0.860 and 0.905 respectively, whereas that of parenchyma was 0.868 and 0.884. Conclusion: The thicknesses of renal cortex, parenchyma measured by CT can reflect renal function. CT was a supplementary method to assess renal function. (authors)

  19. Validation of a simple isotopic technique for the measurement of global and separated renal function

    International Nuclear Information System (INIS)

    Chachati, A.; Meyers, A.; Rigo, P.; Godon, J.P.

    1986-01-01

    Schlegel and Gates described an isotopic method for the measurement of global and separated glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) based on the determination by scintillation camera of the fraction of the injected dose (99mTc-DTPA-[ 131 I]hippuran) present in the kidneys 1-3 min after its administration. This method requires counting of the injected dose and attenuation correction, but no blood or urine sampling. We validated this technique by the simultaneous infusion of inulin and para-amino hippuric acid (PAH) in patients with various levels of renal function (anuric to normal). To better define individual renal function we studied 9 kidneys in patients either nephrectomized or with a nephrostomy enabling separated function measurement. A good correlation between inulin, PAH clearance, and isotopic GFR-ERPF measurement for both global and separate renal function was observed

  20. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  1. Correlation between Creatinine Clearance and Transtubular Potassium Concentration Gradient in old people and chronic renal disease patients

    International Nuclear Information System (INIS)

    Musso, C.; Imperiali, N.; Algranati, L.; Miguel, R.D.; Liakopoulos, V.; Stefanidis, I.

    2007-01-01

    Senescence and chronic kidney disease (CKD) reduce progressively glomerular filtration rate (GFR) which usually results in an increase in potassium renal secretion. To evaluate whether the transtubular potassium concentration gradient (TTKG) is more accurate parameter for evaluating the renal secretion of this cation than using fractional excretion of potassium as its urinary secretion marker, we studied 55 subjects, 43 of them were healthy elderly volunteers and 12 were CKD patients. Exclusion criteria were: abnormal plasma potassium level or presence of any disease or drug that could induce alteration of balance of this electrolyte levels. All the subjects were on a diet with potassium content around 50 mmol/day. The curves, which demonstrate the relationship between creatinine clearance and TTKG and the grade of correlation between these two parameters were analyzed in both groups. We found that the transtubular potassium concentration gradient had a significant negative correlation with the creatinine clearance level in the healthy elderly group, while there was no correlation in the CKD group. (author)

  2. Measurement of Effective Renal Plasma Flow: Evaluation of Clinical Uses in Combination with Renography

    Energy Technology Data Exchange (ETDEWEB)

    Mahadev, V. [Department of Radiotherapy and Nuclear Medicine, General Hospital, Kuala Lumpur (Malaysia)

    1971-02-15

    A comparison of techniques for measuring the renal clearance of Hippuran using a single injection of {sup 131}I sodium orthoiodohippurate in 30 normal subjects and 49 patients showed that a simplified technique using limited samples of blood gave comparable results to more complicated blood and external monitoring techniques without significant loss of accuracy. The clearance value in normal subjects was 645 ml/1.73 m{sup 2} ({+-} 108 ml) and is comparable with results obtained elsewhere. Together with a renogram examination this measurement enables more information to be obtained and helps to distinguish vascular and parenchymal disorders from purely obstructive lesions. It may be useful in the problem of renal tuberculosis and in distinguishing benign kidney lesions from malignant. (author)

  3. Clearance measurements on activated parts of accelerators by combined methods; Verfahrenskombinierte Freigabemessung aktivierter Beschleunigerteile

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, S.; Friedemann, S. [VKTA, Dresden (Germany); Enghardt, W. [Technische Univ. Dresden (Germany). OncoRay

    2016-07-01

    The process of clearance of radioactive materials according to paragraph 29 StrlSchV contents the comparison of activity to mass and surface of the material. To avoid a borderless assessment of activity of activation it is often necessary to use combined measurement methods: For clearance of collimators of a medical proton accelerator (energy range up to 200 MeV) it needs to know the nuclide composition. The energetical and geometrical calibration was fixed by experiments. The clearance based on measurements of activity distribution, gammaspectroscopy verification of nuclide composition and gamma-counting detectors. Parts of medical electron-accelerators achieved its clearance by combination of abovementioned methods and in-situ-gammaspectroscopy. Activated und contaminated lead stones achieved its clearance by measurements of fluence, laboratory evaluation of samples, in-situ-gammaspectroscopy and wipe tests.

  4. A study for promoting measures of social acceptance on clearance system

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Torii, Hiroyuki; Fujii, Yasuhiko

    2007-01-01

    Clearance is one of the useful concepts to manage large amounts of slightly contaminated solid radioactive materials generated from the decommissioning of nuclear facilities. Cleared materials are expected to be disposed of as conventional wastes or recycled to produce consumer goods. In Japan, the legal frame-work for clearance was established in 2005 by amending the Law to regulate nuclear materials, reactors and so on. However, it is not so clear whether the general public understands clearance well. In this paper, major concerns about clearance from the general public are analyzed based on the public comments for reports on clearance prepared by the Nuclear Safety Commission and the Nuclear Institute Safety Agency. The major anxieties for clearance expressed by the general public are the safety of clearance, unknown factors of radiation effects, possibilities of excess radiation exposure due to inadequate measurements of radioactivities and fairness in decision making. In order to deal with those anxieties, some countermeasures including the confidence in nuclear operators and regulatory authorities and controllability of clearance by the general public are discussed to promote the social acceptance of clearance by the general public. (author)

  5. Study to improve the precision of calculation of split renal clearance by gamma camera method using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Tomomitsu, Tatsushi; Yanagimoto, Shinichi

    1999-01-01

    Both fundamental and clinical studies were performed to improve the precision with which split renal clearance is calculated from the relation between renal clearance and the total renal uptake rate by using 99m Tc-MAG 3 , which is mainly excreted into the proximal renal tubules. In the fundamental study, the most suitable kidney phantom threshold values for the extracted renal outline were investigated with regard to size, radioactivity, depth of the kidney phantom, and radioactivity in the background. In the clinical study, suitable timing to obtain additional images for making the ROI and the standard point for calculation of renal uptake rate were investigated. The results indicated that, although suitable threshold values were distributed from 25% to 45%, differences in size, solution activity, and the position of the phantom or BG activity did not have significant effects. Comparing 1-3 min with 2-5 min as the time for additional images for ROI, we found that renal areas using the former time showed higher values, and the correlation coefficient of the regression formula improved significantly. Comparison of the timing for the start of data acquisition with the end of the arterial phase as a standard point of calculating renal uptake rate showed improvement in the latter. (author)

  6. High phenobarbital clearance during continuous renal replacement therapy: a case report and pharmacokinetic analysis.

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-08-01

    Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring.A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure.Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus.The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed.Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring.

  7. Glomerular filtration rate equations overestimate creatinine clearance in older individuals enrolled in the Baltimore Longitudinal Study on Aging: impact on renal drug dosing.

    Science.gov (United States)

    Dowling, Thomas C; Wang, En-Shih; Ferrucci, Luigi; Sorkin, John D

    2013-09-01

    To evaluate the performance of kidney function estimation equations and to determine the frequency of drug dose discordance in an older population. Cross-sectional analysis of data from community-dwelling volunteers randomly selected from the Baltimore Longitudinal Study of Aging from January 1, 2005, to December 31, 2010. A total of 269 men and women with a mean ± SD age of 81 ± 6 years, mean serum creatinine concentration (Scr ) of 1.1 ± 0.4 mg/dl, and mean 24-hour measured creatinine clearance (mClcr ) of 53 ± 13 ml/minute. Kidney function was estimated by using the following equations: Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). The performance of each equation was assessed by measuring bias and precision relative to mClcr . Dose calculation errors (discordance) were determined for 10 drugs requiring renal dosage adjustments to avoid toxicity when compared with the dosages approved by the Food and Drug Administration. The CG equation was the least biased estimate of mClcr . The MDRD and CKD-EPI equations were significantly positively biased compared with CG (mean ± SD 34 ± 20% and 22 ± 15%, respectively, prenal impairment. Thus equations estimating glomerular filtration rate should not be substituted in place of the CG equation in older adults for the purpose of renal dosage adjustments. In addition, the common practice of rounding or replacing low Scr values with an arbitrary value of 1.0 mg/dl for use in the CG equation should be avoided. Additional studies that evaluate alternative eGFR equations in the older populations that incorporate pharmacokinetic and pharmacodynamic outcomes measures are needed. © 2013 Pharmacotherapy Publications, Inc.

  8. Clearance of glucoregulatory peptide hormones during haemodialysis and haemodiafiltration in non-diabetic end-stage renal disease patients

    DEFF Research Database (Denmark)

    Jørgensen, Morten B; Idorn, Thomas; Knop, Filip K

    2015-01-01

    BACKGROUND: Patients with end-stage renal disease (ESRD) have increased fasting concentrations and disturbed postprandial responses of several glucoregulatory hormones. We aimed to evaluate the impact of high-flux haemodialysis (HD) and high-volume haemodiafiltration (HDF) on fasting and postpran......BACKGROUND: Patients with end-stage renal disease (ESRD) have increased fasting concentrations and disturbed postprandial responses of several glucoregulatory hormones. We aimed to evaluate the impact of high-flux haemodialysis (HD) and high-volume haemodiafiltration (HDF) on fasting...... and postprandial plasma levels of glucoregulatory pancreatic and gut peptide hormones in ESRD patients. METHODS: Ten non-diabetic HD-treated ESRD patients were included to undergo a 3-h standardized liquid mixed meal test 1 h into an HD and an HDF, respectively. On a third, optional, examination day, the meal test...... during HDF and four completed the optional meal test without dialysis. All plasma hormone concentrations declined significantly during the first fasting hour of dialysis with no differences between HD and HDF. Significant clearance of the investigated hormones was observed for both dialysis modalities...

  9. Development of a Novel System to Measure a Clearance of a Passenger Platform

    Science.gov (United States)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  10. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  11. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  12. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  13. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    Science.gov (United States)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    Science.gov (United States)

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  15. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    Science.gov (United States)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  16. Increased Renal Clearance of Rocuronium Compensates for Chronic Loss of Bile Excretion, via upregulation of Oatp2.

    Science.gov (United States)

    Wang, Long; Zhou, Mai-Tao; Chen, Cai-Yang; Yin, Wen; Wen, Da-Xiang; Cheung, Chi-Wai; Yang, Li-Qun; Yu, Wei-Feng

    2017-01-13

    Requirement for rocuronium upon surgery changes only minimally in patients with end-stage liver diseases. Our study consisted of both human and rat studies to explore the reason. The reduction rate of rocuronium infusion required to maintain neuromuscular blockade during the anhepatic phase (relative to paleohepatic phase) was examined in 16 children with congenital biliary atresia receiving orthotopic liver transplantation. Pharmacodynamics and pharmacokinetics of rocuronium were studied based on BDL rats. The role of increased Oatp2 and decrease Oatp1 expressions in renal compensation were explored. The reduction of rocuronium requirements significantly decreased in obstructively jaundiced children (24 ± 9 vs. 39 ± 11%). TOF50 in BDL rats was increased by functional removal of the kidneys but not the liver, and the percentage of rocuronium excretion through urine increased (20.3 ± 6.9 vs. 8.6 ± 1.8%), while that decreased through bile in 28d-BDL compared with control group. However, this enhanced renal secretion for rocuronium was eliminated by Oatp2 knock-down, rather than Oatp1 overexpression (28-d BDL vs. Oatp1-ShRNA or Oatp2-ShRNA, 20.3 ± 6.9 vs. 17.0 ± 6.6 or 9.3 ± 3.2%). Upon chronic/sub-chronic loss of bile excretion, rocuronium clearance via the kidneys is enhanced, by Oatp2 up-regulation.

  17. Uptake and washout of I-123-MIBG in neuronal and non-neuronal sites in rat hearts. Relationship to renal clearance

    International Nuclear Information System (INIS)

    Arbab, A.S.; Koizumi, Kiyoshi; Araki, Tsutomu

    1996-01-01

    We investigated the uptake and washout of I-123-metaiodobenzylguanidine (MIBG) in neuronal (both intra-and extravesicular) and non-neuronal sites in the heart and its relationship to renal clearance. Acute renal failure was induced in rats by ligating the renal vessels, and the findings were compared with those of sham-operated rats. Each group consisted of control, reserpine-treated and 6-hydroxydopamine (6-OHDA)-treated subgroups. Rats were sacrificed at 10 minutes and 4 hours after injection of MIBG. MIBG activity was calculated in specimens of heart, spleen, lung and blood. At 10 minutes, no significant difference in MIBG uptake in the heart was observed among the subgroups or between sham-operated and renal failure rats despite a significantly higher blood MIBG activity in the latter. At 4 hours, however, the hearts of both reserpine-treated and 6-OHDA-treated rats showed significantly lower MIBG uptake than control rats. Furthermore, the hearts of renal failure rats showed higher MIBG uptake in the control and reserpine-treated rats than in the corresponding subgroups in sham-operated rats. Intra and extravesicular neuronal uptake of MIBG in the heart were estimated using control, reserpine-treated and 6-OHDA-treated rats. Vesicular uptake values were similar in both the sham-operated group (0.51% ID/g) and the renal failure group (0.44% ID/g). But extravesicular neuronal uptake values were quite different in the renal failure group (0.86% ID/g) and the sham-operated group (0.19% ID/g). In conclusion, uptake to and washout from extravesicular neuronal sites may depend on the concentration of MIBG in the blood or the state of renal clearance, but vesicular uptake may be independent of these factors. (author)

  18. Development of Gold Nanoparticle towards Radioenhancement Therapy, Renal Clearance, siRNA Delivery and Light-Controlled Gene Silencing

    Science.gov (United States)

    Wang, Jianxin

    Gold nanoparticles (GNPs) have been widely studied and used in research for diagnostic, prophylactic or therapeutic purposes. However, they still face many technical challenges before they can be used to effectively address unmet biomedical needs. The theme of this dissertation is focused on addressing challenges of GNPs in clinical translation, and to improve their potential for application in radioenhancement therapy and siRNA delivery. We demonstrate the facile self-assembly of micellar gold nanocapsules using zwitterionic surfactants, with hydrodynamic diameters below 10 nm, which holds promise for good renal clearance to promote the excretion of GNPs in human body. We also prepared PEI- and PEG-coated GNPs and demonstrated their uptake into HeLa cells with exposure to soft X-rays (120 kVp), based on the consideration that the proximity of GNPs to nuclear DNA may be beneficial for enhancing low-energy ionizing radiotherapy. GNP-mediated siRNA delivery may be challenged by nonspecific siRNA desorption during circulation, which can cause off-target effects and immunogenicity. The use of gold nanorods (GNRs) for siRNA delivery also faces challenges like reduced dispersion stability during siRNA functionalization. We developed an effective way to load siRNA onto GNRs at high density, using oleylsulfobetaine (OSB) as an intermediate surfactant and dithiocarbamates (DTCs) as desorption-resistant anchors for siRNA. The GNR?siRNA complexes provided excellent control for laser-triggered gene silencing.

  19. Pleural liquid clearance rate measured in awake sheep by the volume of dilution method

    International Nuclear Information System (INIS)

    Broaddus, V.C.; Wiener-Kronish, J.P.; Berthiaume, Y.; Staub, N.C.

    1986-01-01

    The authors reported 24h clearance of mock pleural effusions measured terminally in sheep. To measure effusion volume at different times in the same sheep, they injected 111 In-transferrin and measured its dilution. In 5 sheep with effusions of known sizes, the method was accurate to +/-10%. In 5 awake sheep, the authors injected 10 ml/kg of a 1% protein solution via a non-penetrating rib capsule. At 6h, the authors measured the volume by the dilution method and at 24h by direct recovery. The clearance rate in each animal was constant at 2.9-6.0%/h (average 4.8 +/- 1.3%/h). This new method gives a reliable two point clearance rate and requires fewer animals

  20. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K. [Heidelberg Univ., Mannheim (Germany). Dept. of Medicine V

    2017-05-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  1. Quantitative arterial spin labelling perfusion measurements in rat models of renal transplantation and acute kidney injury at 3 T

    International Nuclear Information System (INIS)

    Zimmer, Fabian; Schad, Lothar R.; Zoellner, Frank G.; Klotz, Sarah; Hoeger, Simone; Yard, Benito A.; Kraemer, Bernhard K.

    2017-01-01

    To employ ASL for the measurement of renal cortical perfusion in particular renal disorders typically associated with graft loss and to investigate its potential to detect and differentiate the related functional deterioration i.e., in a setting of acute kidney injury (AKI) as well as in renal grafts showing acute and chronic transplant rejection. 14 Lewis rats with unilateral ischaemic AKI and 43 Lewis rats with renal grafts showing acute or chronic rejections were used. All ASL measurements in this study were performed on a 3 T MR scanner using a FAIR True-FISP approach to assess renal blood flow (RBF). Perfusion maps were calculated and the cortical blood flow was determined using a region-of-interest based analysis. RBF of healthy and AKI kidneys as well as of both rejection models, were compared. In a subsample of 20 rats, creatinine clearance was measured and correlated with cortical perfusion. RBF differs significantly between healthy and AKI kidneys (P < 0.001) with a mean difference of 213 ± 80 ml/100 g/min. Renal grafts with chronic rejections show a significantly higher (P < 0.001) mean cortical perfusion (346 ± 112 ml/100 g/min) than grafts with acute rejection (240 ± 66 ml/100 g/min). Both transplantation models have a significantly (P < 0.001) lower perfusion than healthy kidneys. Renal creatinine clearance is significantly correlated (R = 0.85, P < 0.001) with cortical blood flow. Perfusion measurements with ASL have the potential to become a valuable diagnostic tool, regarding the detection of renal impairment and the differentiation of disorders that lead to a loss of renal function and that are typically associated with graft loss.

  2. Creatinine measurements often yielded false estimates of progression in chronic renal failure

    International Nuclear Information System (INIS)

    Walser, M.; Drew, H.H.; LaFrance, N.D.

    1988-01-01

    In 9 of 22 observation periods (lasting an average of 15 months) in 17 patients with moderate to severe chronic renal failure (GFR 4 to 23 ml/min), rates of progression as estimated from the linear regression on time of 24-hour creatinine clearance (b1) differed significantly from rates of progression as estimated from the regression on time of urinary clearance of 99mTc-DTPA (b2), during all or part of the period of observation. b1 exceeded b2 in four cases and was less than b2 in the other five. Thus there were gradual changes in the fractional tubular secretion of creatinine in individual patients, in both directions. Owing to these changes, measurements of creatinine clearance gave erroneous impressions of the rate or existence of progression during all or a portion of the period of observation in nearly half of these patients. In the 22 studies as a group, using the entire periods of observation, b1 indicated significantly more rapid progression (by 0.18 +/- 0.06 ml/min/month, P less than 0.01) than did b2, and had a significantly greater variance. Measurements of progression based on the rate of change of reciprocal plasma creatinine (multiplied by an average rate of urinary creatinine excretion in each study) were equally misleading, even though less variable. We conclude that sequential creatinine measurements are often misleading as measures of progression and should, when feasible, be replaced by urinary clearance of isotopes in following patients with chronic renal failure

  3. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  4. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  5. Clearance measurement for waste concerning contained radioactivity; Frei(gabe)messung von Abfall hinsichtlich enthaltener Radioaktivitaet

    Energy Technology Data Exchange (ETDEWEB)

    Sokcic-Kostic, Marina; Schultheis, Roland [NUKEM Technologies Engineering Services GmbH, Alzenau (Germany)

    2016-12-15

    Clearance measurements are always a compromise between requirements of the measurement technology and economic boundary conditions. Depending on the quantity and the type of waste, different solutions are obtained. For large volumes of more or less homogeneous waste, the conveyor belt method is the biggest favorite, which has already proved its suitability in practice. This is important, because numerous nuclear power stations are being decommissioned in Germany in the coming years and large quantities of waste will be arising. For some applications, e.g. Tritium or C-14, satisfying solutions either do not exist or are currently in the development stages. There is still great potential for the development of clearance methods.

  6. Bone blood flow measured by 41Ar clearance formed by 44Ca(n,α)41Ar

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.

    1983-01-01

    A technique to measure regional inert gas washout in bone, in vivo, by measuring 41 Ar clearance formed by fast-neutron activation of 44 Ca has been developed. Following fast-neutron irradiation of whole rats, the perfusion-limited clearance of 41 Ar was measured for both dead and living rats. The clearance rate for the live rats indicate that the bone perfusion is in the range of 3 to 20 ml/100 Argon distribution volume

  7. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    Shames, D.M.; Korobkin, M.

    1976-01-01

    To determine whether externally monitored early renal uptake of 131 I-hippurate is proportional to renal blood flow, the renal uptake of 131 -hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131 I-hippurate, about 1 μCi of either 85 Sr- or 95 Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131 I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131 I-hippurate

  8. Prediction of the overall renal tubular secretion and hepatic clearance of anionic drugs and a renal drug-drug interaction involving organic anion transporter 3 in humans by in vitro uptake experiments.

    Science.gov (United States)

    Watanabe, Takao; Kusuhara, Hiroyuki; Watanabe, Tomoko; Debori, Yasuyuki; Maeda, Kazuya; Kondo, Tsunenori; Nakayama, Hideki; Horita, Shigeru; Ogilvie, Brian W; Parkinson, Andrew; Hu, Zhuohan; Sugiyama, Yuichi

    2011-06-01

    The present study investigated prediction of the overall renal tubular secretion and hepatic clearances of anionic drugs based on in vitro transport studies. The saturable uptake of eight drugs, most of which were OAT3 substrates (rosuvastatin, pravastatin, pitavastatin, valsartan, olmesartan, trichlormethiazide, p-aminohippurate, and benzylpenicillin) by freshly prepared human kidney slices underestimated the overall intrinsic clearance of the tubular secretion; therefore, a scaling factor of 10 was required for in vitro-in vivo extrapolation. We examined the effect of gemfibrozil and its metabolites, gemfibrozil glucuronide and the carboxylic metabolite, gemfibrozil M3, on pravastatin uptake by human kidney slices. The inhibition study using human kidney slices suggests that OAT3 plays a predominant role in the renal uptake of pravastatin. Comparison of unbound concentrations and K(i) values (1.5, 9.1, and 4.0 μM, for gemfibrozil, gemfibrozil glucuronide, and gemfibrozil M3, respectively) suggests that the mechanism of the interaction is due mainly to inhibition by gemfibrozil and gemfibrozil glucuronide. Furthermore, extrapolation of saturable uptake by cryopreserved human hepatocytes predicts clearance comparable with the observed hepatic clearance although fluvastatin and rosuvastatin required a scaling factor of 11 and 6.9, respectively. This study suggests that in vitro uptake assays using human kidney slices and hepatocytes provide a good prediction of the overall tubular secretion and hepatic clearances of anionic drugs and renal drug-drug interactions. It is also recommended that in vitro-in vivo extrapolation be performed in animals to obtain more reliable prediction.

  9. Alpha radioactivity measurement technology with ionized air type measurement. Applicability evaluation to verification of the clearance level

    International Nuclear Information System (INIS)

    Mita, Yutaka; Matsumura, Toshihiro; Yokoyama, Kaoru; Sugitsue, Noritake

    2008-10-01

    The purpose of this test is to evaluate the applicability of the clearance level measuring system by Ionized Air Type Measurement after decontaminated by sulfuric acid sample. In Ningyo-toge Environmental Engineering Center. The equipment and radioactive waste which were contaminated with uranium are generated so much in future dismantling stage. In our plan, some of equipments and radioactive waste are contaminated to a clearance level, and cut down on decommission and disposal expense. This plan needs the alpha-rays measurement technology of the very low level. We think that ionized Air transfer measurement technology is promising as of clearance verification technology. The ionized Air transfer measurement technology applied to the Ionized Air Type Measurement can measure plan radioactivity of a very low level. Moreover, as compared with a direct survey, there is the merit which can be measured in a short time. However ionized Air transfer measurement technology is new technology. Therefore, there is almost no measurement track record. Furthermore, the date about the influence of a background, a detection limit, measurement performance, and reliability is insufficient. So, this measurement test estimated applicability as clearance level verification of an Ionized Air Type Measurement. (author)

  10. Noninvasive measurement of an index of renal blood flow

    International Nuclear Information System (INIS)

    Powers, T.A.; Rees, R.S.; Bowen, R.D.

    1983-01-01

    A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compartmental analysis principles. There is good correlation between renal blood flow estimated by this technique and that determined by microsphere injection

  11. Accuracy and precision of the CKD-EPI and MDRD predictive equations compared with glomerular filtration rate measured by inulin clearance in a Saudi population.

    Science.gov (United States)

    Al-Wakeel, Jamal Saleh

    2016-01-01

    Predictive equations for estimating glomerular filtration rate (GFR) in different clinical conditions should be validated by comparing with the measurement of GFR using inulin clearance, a highly accurate measure of GFR. Our aim was to validate the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) equations by comparing it to the GFR measured using inulin clearance in chronic kidney disease (CKD) patients. Cross-sectional study performed in adult Saudi patients with CKD. King Saud University Affiliated Hospital, Riyadh, Saudi Arabia in 2014. We compared GFR measured by inulin clearance with the estimated GFR calculated using CKD-EPI and MDRD predictive formulas. Correlation, bias, precision and accuracy between the estimated GFR and inulin clearance. Comparisons were made in 31 participants (23 CKD and 8 transplanted), including 19 males (mean age 42.2 [15] years and weight 68.7 [18] kg). GFR using inulin was 51.54 (33.8) mL/min/1.73 m2 in comparison to inulin clearance, the GFR by the predictive equations was: CKD-EPI creatinine 52.6 (34.4) mL/ min/1.73 m2 (P=.490), CKD-EPI cystatin C 41.39 (30.30) mL/min/1.73 m2 (P=.002), CKD creatinine-cystatin C 45.03 (30.9) mL/min/1.73 m2 (P=.004) and MDRD GFR 48.35 (31.5) mL/min/1.73 m2 (P=.028) (statistical comparisons vs inulin). Bland-Altman plots demonstrated that GFR estimated by the CKD-EPI creatinine was the most accurate compared with inulin clearance, having a mean difference (estimated bias) and limits of agreement of -1.1 (15.6,-17.7). By comparison the mean differences for predictive equations were: CKD-EPI cystatin C 10.2 (43.7,-23.4), CKD creatinine-cystatin C 6.5 (29.3,-16.3) and MDRD 3.2 (18.3,-11.9). except for CKD-EPI creatinine, all of the equations underestimated GFR in comparison with inulin clearance. When compared with inulin clearance, the CKD-EPI creatinine equation is the most accurate, precise and least biased equation for estimation of GFR

  12. Activity measurement algorithm in solid radioactive waste clearance procedure

    International Nuclear Information System (INIS)

    Hinca, R.; Skala, L.

    2014-01-01

    Most of European metrology experts prefer in radiation wastes characterization process to use scaling factor method in combination with high definition gamma spectrometry rather than radionuclide vector method in combination with gross gamma activity measurement. The second method is actually used in Slovakian nuclear facilities. The international (IAEA) and Slovak national authorities (UVZ) recognize both approach but there is a fact, that high definition gamma spectrometry radionuclides more properly. (authors)

  13. Kidney function measured by clearance. Methods and indications. An update; Zur Messung der Nierenfunktion durch Clearancebestimmungen. Methoden und Indikationen. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Durand, E. [Universitaetskrankenhaus Bicetre, Paris (France); Mueller-Suur, R. [Karolinska Inst., Danderyds Krankenhaus und Aleris Fysiologlab, Stockholm (Sweden)

    2010-09-15

    Renal function impairment can be monitored by many tests. Measurement of plasma-creatinine level is the most used method, 24 h plasma-creatininclearance with urine collection is used by others and also other alternative but indirect methods exist. However, the use of radionuclide-clearances is by far the easiest performed method with the highest accuracy and precision and gives very low irradiation dose. In the following we will discuss the different radiopharmaceuticals in use, their plus and minus, the different clearance methods in use, their limitations and give some clinically important indications to perform clearance investigations according to consensus reports. Summarizing the use of plasma clearance of 51-Cr-EDTA after a single injection with one blood sample can be generally recommended, however with some modifications in special clinical situations, which are pointed out. Please note, that this paper is, for a significant part, an update of a previous paper published 2003 in ''Der Nuklearmediziner'' (orig.)

  14. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan

    International Nuclear Information System (INIS)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-01-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) “Regulations on Clearance Level for Radioactive Waste Management”. The testing results should conform to the deviation and traceability requirements. - Highlights: • The participating laboratories must completely conform to the ISO/IEC 17025 • The proficiency testing items were basically in two categories, box and barrel types • Analyzed the MDA and that should be less than 20% of the release level given in the AEC. • The are three limitations: MDA< AMDA, -0.25< Bi<+0.5, and En≤1.0 and uncertainty<20%

  15. Comparison of glomerular filtration rates derived from dynamic renal imaging and dual sample clearance in kidney transplantation

    International Nuclear Information System (INIS)

    Zhu Yangjun; Li Linfa; Zhang Jun; Du Xiaoying

    2007-01-01

    Objective: Glomerular filtration rate (GFR) is one of the valuable indictors of allograft status after kidney transplantation. The feasibility of an easy measurement of GFR by dynamic renal imaging (dGFR) was assessed in comparison to a classical dual plasma sample method (tGFR) in the current study for evaluating the function of grafting kidney. Methods: In 73 patients of kidney transplantation, both dynamic renal imaging and dual sample GFR measurement were undertaken after 99 Tc m -DTPA injection. The correlation between dGFR and tGFR, both being standardized according to surface area, was analyzed and the linear regression equation was obtained. Results: The mean dGFR was slightly lower than that of tGFR (t=-2.010, P<0.05). The dGFR correlated significantly with tGFR (r=0.759, P< 0.01). The linear regression equation was tGFR=0.6455 x dGFR + 25.514. Conclusion: The dGFR correlated well with tGFR and they were accurate in evaluating the filtration function of transplanted kidney. (authors)

  16. A dosing algorithm for metformin based on the relationships between exposure and renal clearance of metformin in patients with varying degrees of kidney function.

    Science.gov (United States)

    Duong, Janna K; Kroonen, M Y A M; Kumar, S S; Heerspink, H L; Kirkpatrick, C M; Graham, G G; Williams, K M; Day, R O

    2017-08-01

    The aims of this study were to investigate the relationship between metformin exposure, renal clearance (CL R ), and apparent non-renal clearance of metformin (CL NR /F) in patients with varying degrees of kidney function and to develop dosing recommendations. Plasma and urine samples were collected from three studies consisting of patients with varying degrees of kidney function (creatinine clearance, CL CR ; range, 14-112 mL/min). A population pharmacokinetic model was built (NONMEM) in which the oral availability (F) was fixed to 0.55 with an estimated inter-individual variability (IIV). Simulations were performed to estimate AUC 0-τ , CL R , and CL NR /F. The data (66 patients, 327 observations) were best described by a two-compartment model, and CL CR was a covariate for CL R . Mean CL R was 17 L/h (CV 22%) and mean CL NR /F was 1.6 L/h (69%).The median recovery of metformin in urine was 49% (range 19-75%) over a dosage interval. When CL R increased due to improved renal function, AUC 0-τ decreased proportionally, while CL NR /F did not change with kidney function. Target doses (mg/day) of metformin can be reached using CL CR /3 × 100 to obtain median AUC 0-12 of 18-26 mg/L/h for metformin IR and AUC 0-24 of 38-51 mg/L/h for metformin XR, with C max  kidney function to maintain consistent drug exposure. However, there is still marked IIV and therapeutic drug monitoring of metformin plasma concentrations is recommended.

  17. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  18. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    International Nuclear Information System (INIS)

    Luedemann, Lutz; Nafz, B.; Persson, P.; Elsner, F.; Grosse-Siestrup, C.; Meissler, M.; Gutberlet, M.; Univ. Leipzig/ Leipzig Heart Center; Lengsfeld, P.; Voth, M.

    2011-01-01

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  19. Application of measuring 99mTc-MAG3 plasma clearance based on one-compartment model (MPC method) to pediatric patients

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Higashida, Kousuke; Arbab, A.S.; Toyama, Keiji; Arai, Takao; Yoshitomi, Tatsuya.

    1997-01-01

    Measurement of 99m Tc-MAG3 plasma clearance based on 1-compartment model (MPC method) were applied to 12 pediatric patients and evaluated for the factors which might affect the calculated results. Depth correction is a critical factor for the measurement of renal uptake. Three different equations for estimating renal depth were compared with the real depth measured by ultrasonography. The equation proposed by K. Itoh was suitable though the equations by T. Ito and Raynaud were insufficient. Estimation of distribution volume, which is regarded as circulating plasma volume (CPV), is also critical for the calculation of MAG3 clearance by MPC method. Precisely, hematocrit measured by venous sampling and circulating blood volume (CBV) calculated as 7.5% of body weight are used for estimation of CPV. However, assumed CPV as 5% of body weight was acceptable if the hematocrit was not severely deviated from the normal value. Simplified MPC method utilizing two factors mentioned above gave a positive correlation with Russell's one point sampling method. In conclusion, MPC method is applicable for pediatric patients. (author)

  20. The detailed measurement of foot clearance by young adults during stair descent.

    Science.gov (United States)

    Telonio, A; Blanchet, S; Maganaris, C N; Baltzopoulos, V; McFadyen, B J

    2013-04-26

    Foot clearance is an important variable for understanding safe stair negotiation, but few studies have provided detailed measures of it. This paper presents a new method to calculate minimal shoe clearance during stair descent and compares it to previous literature. Seventeen healthy young subjects descended a five step staircase with step treads of 300 mm and step heights of 188 mm. Kinematic data were collected with an Optotrak system (model 3020) and three non-colinear infrared markers on the feet. Ninety points were digitized on the foot sole prior to data collection using a 6 marker probe and related to the triad of markers on the foot. The foot sole was reconstructed using the Matlab (version 7.0) "meshgrid" function and minimal distance to each step edge was calculated for the heel, toe and foot sole. Results showed significant differences in minimum clearance between sole, heel and toe, with the shoe sole being the closest and the toe the furthest. While the hind foot sole was closest for 69% of the time, the actual minimum clearance point on the sole did vary across subjects and staircase steps. This new method, and the findings on healthy young subjects, can be applied to future studies of other populations and staircase dimensions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  2. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  3. What method to use for the renal clearance with {sup 51}Cr-E.D.T.A.: retrospective study among 1157 adults and 286 children; Quelle methode de mesure utiliser pour la clairance renale au 51Cr-EDTA: etude retrospective chez 1157 adultes et 286 enfants

    Energy Technology Data Exchange (ETDEWEB)

    Lacoeuille, F.; Machefert, N.; Vervueren, L.; Berthelot, C.; Rakotonirina, H.; Le Jeune, J.J.; Couturier, O. [CHU d' Angers, Service de medecine nucleaire, 49 (France); Drablier, G.; Cahouet-Vannier, A. [CHU d' Angers, Service de pharmacie, 49 (France); Denizot, B. [CH Annemasse, service de medecine nucleaire, 74 (France)

    2010-07-01

    Purpose: in the objective to make our practices evolve and to limit the numbers of sampling for patients, we searched to determine if the methods used (4,2 or 1 sampling) to measure the renal clearance to {sup 51}Cr-EDTA give results comparable on the population of patients concerned by this examination. Conclusions: This study allowed to enlighten interchangeability between the four points and two points method for the population studied. It allows to consider a change in our practice for the profit of a two points methods. (N.C.)

  4. An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig

    Directory of Open Access Journals (Sweden)

    María Asunción Illarramendi

    2013-06-01

    Full Text Available When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.

  5. A computerized system for handling renal size measurements from urograms

    International Nuclear Information System (INIS)

    Claesson, I.; Jacobsson, B.F.; Riha, M.

    1987-01-01

    The size of a kidney, as measured on an urogram, is a sensitive indicator of renal damage in a child with urinary tract infection, and renal surface area correlates well with glomerular filtration rate. Sequential measurements can be invaluable in evaluating the efficacy of a regimen of treatment. A system utilizing a personal microcomputer has been developed to facilitate the measuring procedure and the handling and analysis of data. (orig.)

  6. Direct measurement of first-pass ileal clearance of a bile acid in humans

    International Nuclear Information System (INIS)

    Galatola, G.; Jazrawi, R.P.; Bridges, C.; Joseph, A.E.; Northfield, T.C.

    1991-01-01

    The purpose of this study was to develop and validate a method of directly measuring ileal bile acid absorption efficiency during a single enterohepatic cycle (first-pass ileal clearance). This has become feasible for the first time because of the availability of the synthetic gamma-labeled bile acid 75Selena-homocholic acid-taurine (75SeHCAT). Together with the corresponding natural bile acid cholic acid-taurine (labeled with 14C), SeHCAT was infused distal to an occluding balloon situated beyond the ampulla of Vater in six healthy subjects. Completion of a single enterohepatic cycle was assessed by obtaining a plateau for 75SeHCAT activity proximal to the occluding balloon, which prevented further cycles. Unabsorbed 75SeHCAT was collected after total gut washout, which was administered distal to the occluding balloon. 75SeHCAT activity in the rectal effluent measured by gamma counter was compared with that of absorbed 75SeHCAT level measured by gamma camera and was used to calculate first-pass ileal clearance. This was very efficient (mean value, 96%) and showed very little variation in the six subjects studied (range, 95%-97%). A parallel time-activity course in hepatic bile for 14C and 75Se during a single enterohepatic cycle, together with a ratio of unity for 14C/75Se in samples obtained at different time intervals, suggests that 75SeHCAT is handled by the ileum like the natural bile acid cholic acid-taurine. Extrapolation of 75SeHCAT first-pass ileal clearance to that of the natural bile acid therefore seems justifiable. In a subsidiary experiment, ileal absorption efficiency per day for 75SeHCAT was also measured by scanning the gallbladder area on 5 successive days after the measurement of first-pass ileal clearance. In contrast with absorption efficiency per cycle, absorption efficiency per day varied widely (49%-86%)

  7. Novel lanthanide-labeled metal oxide nanoparticles improve the measurement of in vivo clearance and translocation

    Directory of Open Access Journals (Sweden)

    Abid Aamir D

    2013-01-01

    Full Text Available Abstract The deposition, clearance and translocation of europium-doped gadolinium oxide nanoparticles in a mouse lung were investigated experimentally. Nanoparticles were synthesized by spray flame pyrolysis. The particle size, crystallinity and surface properties were characterized. Following instillation, the concentrations of particles in organs were determined with inductively coupled plasma mass spectrometry. The protein corona coating the nanoparticles was found to be similar to the coating on more environmentally relevant nanoparticles such as iron oxide. Measurements of the solubility of the nanoparticles in surrogates of biological fluids indicated very little propensity for dissolution, and the elemental ratio of particle constituents did not change, adding further support to the contention that intact nanoparticles were measured. The particles were intratracheally instilled into the mouse lung. After 24 hours, the target organs were harvested, acid digested and the nanoparticle mass in each organ was measured by inductively coupled plasma mass spectrometry (ICP-MS. The nanoparticles were detected in all the studied organs at low ppb levels; 59% of the particles remained in the lung. A significant amount of particles was also detected in the feces, suggesting fast clearance mechanisms. The nanoparticle system used in this work is highly suitable for quantitatively determining deposition, transport and clearance of nanoparticles from the lung, providing a quantified measure of delivered dose.

  8. Velocity and pressure measurements in guide vane clearance gap of a low specific speed Francis turbine

    Science.gov (United States)

    Thapa, B. S.; Dahlhaug, O. G.; Thapa, B.

    2016-11-01

    In Francis turbine, a small clearance gap between the guide vanes and the cover plates is usually required to pivot guide vanes as a part of governing system. Deflection of cover plates and erosion of mating surfaces causes this gap to increase from its design value. The clearance gap induces the secondary flow in the distributor system. This effects the main flow at the runner inlet, which causes losses in efficiency and instability. A guide vane cascade of a low specific speed Francis turbine has been developed for experimental investigations. The test setup is able to produce similar velocity distributions at the runner inlet as that of a reference prototype turbine. The setup is designed for particle image velocimetry (PIV) measurements from the position of stay vane outlet to the position of runner inlet. In this study, velocity and pressure measurements are conducted with 2 mm clearance gap on one side of guide vane. Leakage flow is observed and measured together with pressure measurements. It is concluded that the leakage flow behaves as a jet and mixes with the main flow in cross-wise direction and forms a vortex filament. This causes non-uniform inlet flow conditions at runner blades.

  9. Regional cerebral blood flow measurements using noninvasive 133Xe clearance method in children

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Maeda, Koji; Kagawa, Yukihide; Morozumi, Kunihiko; Hashimoto, Manami; Tsubokawa, Takashi.

    1985-01-01

    The noninvasive 133-Xe clearance method of estimating rCBF has been widely used in adult clinical studies. It is safe, noninvasive and reproducible, and has provided valuable insight into adult cerebrovascular pathophysiology. However, in children, this technique has not been used to measure rCBF for some fundamental problems. This study was performed to clarify these fundamental problems for applications of noninvasive 133-Xe clearance technique to children. The results showed that three fundamental problems concerning; (1) volume of dead spaces in airway circuits of the system, (2) increasing of look-through phenomenon and (3) correction methods for recirculated 133-Xe and airway artifacts to estimate rCBF are important for applications to children. These problems should be improved to measure as correct rCBF in children as in adults. (author)

  10. Association of clearance of middle- and large-molecular-weight substance with arterial stiffness and left ventricular mass in children receiving renal replacement therapy.

    Science.gov (United States)

    Özdemir, Kadriye; Yilmaz, Ebru; Dincel, Nida; Bozabali, Sibel; Apaydin, Sukriye; Gun, Zubeyr H; Sozeri, Betul; Mir, Sevgi

    2017-12-01

    The prominent cause of mortality in children receiving dialysis treatment is cardiovascular diseases. Risk factors related to chronic renal disease, are effective in the development of cardiovascular diseases. The aim of study was to investigate cardiovascular system (CVS) involvement for functional and structural alterations in children receiving dialysis, and display any association between cardiovascular morbidity and uremic toxins. 20 dialysis patients and 20 healthy controls were included to the study. Clearance of small, middle and large molecular-weight uremic toxins was evaluated in blood samples collected 30 minutes before (D0) and 2 hour after dialysis (D2), and change value was calculated as D0-D2/D0. Cardiovascular involvement was determined by comparing arterial stiffness, carotid intima-media thickness (CIMT) and Left Ventricular Mass Index (LVMI) with the control group. Four patients receiving hemodialysis and two patients in continuous ambulatory peritoneal dialysis (CAPD) group who have significant differences in all functional and structural parameters were detected. Four dialysis patients with detected cardiovascular disease have distinctively lower beta-2 microglobulin and homocysteine clearances compared to the patients with no CVS involvement. The clearance of middle and large molecular-weight substances should be closely monitored in children receiving dialysis.

  11. Iohexol plasma clearance measurement in older adults with chronic kidney disease-sampling time matters.

    Science.gov (United States)

    Ebert, Natalie; Loesment, Amina; Martus, Peter; Jakob, Olga; Gaedeke, Jens; Kuhlmann, Martin; Bartel, Jan; Schuchardt, Mirjam; Tölle, Markus; Huang, Tao; van der Giet, Markus; Schaeffner, Elke

    2015-08-01

    Accurate and precise measurement of GFR is important for patients with chronic kidney disease (CKD). Sampling time of exogenous filtration markers may have great impact on measured GFR (mGFR) results, but there is still uncertainty about optimal timing of plasma clearance measurement in patients with advanced CKD, for whom 24-h measurement is recommended. This satellite project of the Berlin Initiative Study evaluates whether 24-h iohexol plasma clearance reveals a clinically relevant difference compared with 5-h measurement in older adults. In 104 participants with a mean age of 79 years and diagnosed CKD, we performed standard GFR measurement over 5 h (mGFR300) using iohexol plasma concentrations at 120, 180, 240 and 300 min after injection. With an additional sample at 1440 min, we assessed 24-h GFR measurement (mGFR1440). Study design was cross-sectional. Calculation of mGFR was conducted with a one compartment model using the Brochner-Mortensen equation to calculate the fast component. mGFR values were compared with estimated GFR values (MDRD, CKD-EPI, BIS1, Revised Lund-Malmö and Cockcroft-Gault). In all 104 subjects, mGFR1440 was lower than mGFR300 (23 ± 8 versus 29 ± 9 mL/min/1.73 m(2), mean ± SD; P clearance up to 5 h leads to a clinically relevant overestimation of GFR compared with 24-h measurement. In clinical care, this effect should be bore in mind especially for patients with considerably reduced GFR levels. A new correction formula has been developed to predict mGFR1440 from mGFR300. For accurate GFR estimates in elderly CKD patients, we recommend the Revised Lund Malmö equation. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  12. Rapid decline in 51Cr-EDTA measured renal function during the first weeks following lung transplantation

    DEFF Research Database (Denmark)

    Hornum, M.; Iversen, M.; Steffensen, I.

    2009-01-01

    We previously described a 54% decline in renal function at 6 months after lung transplantation (LTx). We hypothesized that this decline is a very early event following LTx. Thirty-one consecutive patients (16 females/15 males), mean age 49 (+/-13) years, with emphysema, cystic fibrosis/bronchiect......We previously described a 54% decline in renal function at 6 months after lung transplantation (LTx). We hypothesized that this decline is a very early event following LTx. Thirty-one consecutive patients (16 females/15 males), mean age 49 (+/-13) years, with emphysema, cystic fibrosis....../bronchiectasis or idiopathic pulmonary fibrosis were included in an analysis of renal function before and after LTx. The glomerular filtration rate (GFR) was measured using the (51)Cr-ethylenediaminetetra acetic acid plasma clearance single injection technique (mGFR) at baseline before transplantation and at 1, 2, 3 and 12...

  13. Cine-CT measurement of cortical renal blood flow

    International Nuclear Information System (INIS)

    Jaschke, W.R.; Gould, R.G.; Cogan, M.G.; Sievers, R.; Lipton, M.J.

    1987-01-01

    A modified indicator-dilution technique using radiographic contrast material and a cine-CT scanner was used to measure blood flow in the renal cortex of dogs. To validate this technique, CT measurements were correlated with simultaneous measurements of flow determined by radioactive microspheres. Measurements were taken during euvolemic conditions and after hemorrhage. Thirty-nine measurements were compared, covering a flow range from 1 to 7 ml min-1 g-1, and a good correlation was found between the cine-CT and microsphere results (r = 0.93; p less than 0.001). Additionally, cine-CT measurements were made of the mean transit time (MTT) of contrast material through the renal cortex, and the reciprocal of these MTT values was also well correlated to microsphere determined flow (r = 0.94; p less than 0.001). Thus, cine-CT appears to be a promising new technique for measuring renal blood flow

  14. Measurement of contact angle in a clearance-fit pin-loaded hole

    Science.gov (United States)

    Prabhakaran, R.; Naik, R. A.

    1986-01-01

    A technique which measures load-contact variation in a clearance-fit, pin-loaded hole is presented in detail. A steel instrumented pin, which activates a make-or-break electrical circuit in the pin-hole contact region, was inserted into one aluminum and one polycarbonate specimen. The resulting load-contact variations are indicated schematically. The ability to accurately determine the arc of contact at any load was crucial to this measurement. It is noted that this simple experimental technique is applicable to both conducting and nonconducting materials.

  15. Reduced clearance of rocuronium and sugammadex in patients with severe to end-stage renal failure: a pharmacokinetic study.

    NARCIS (Netherlands)

    Staals, L.M.; Snoeck, M.M.J.; Driessen, J.J.; Hamersvelt, H.W. van; Flockton, E.A.; Heuvel, M.W. van den; Hunter, J.M.

    2010-01-01

    BACKGROUND: Sugammadex is a selective relaxant binding agent designed to encapsulate the neuromuscular blocking agent, rocuronium. The sugammadex-rocuronium complex is eliminated by the kidneys. This trial investigated the pharmacokinetics (PKs) of sugammadex and rocuronium in patients with renal

  16. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance

    DEFF Research Database (Denmark)

    Jødal, Lars; Brøchner-Mortensen, Jens

    2009-01-01

    were within ±8 % for adults and ±13 % for children (95 % limits of agreement). Conclusions. The true relationship between Cl and Cl1 of 51Cr-EDTA is given, resulting in a common correction equation applicable for children and adults. The new equation has better mathematical behaviour than quadratic......, a (minutes), not used for determination of Cl1, were measured. Results. The true relationship between Cl and Cl1 is given by Cl = Cl1/(1+f·Cl1), where f = a/PV. For men, women and children alike, the equation f = 0.0032·BSA-1.3 was applicable (BSA = body surface area in m²). Estimation errors on clearance...... equations on very high values of clearance and takes into account dependence on body size....

  17. Measurement of Regional and Global Pulmonary Clearance of 99mTc-DTPA (Demethylamitriptylene-Acetate): An Index of Alveolar Epithelial Permeability

    International Nuclear Information System (INIS)

    Vaskova, Olivija

    1996-01-01

    The main purpose of this study has been introduction of a new method for alveoli-capillary permeability evaluation. Many reports pointed out to the altered transit of soluble particles through this barrier. From pathophysiological aspect the main interest is the elucidation of permeability's alteration in different pulmonary pathology. We decided to use for lung epithelial permeability measurements 99m Tc-DTPA inhaled aerosols and sequential assessment of its lung clearance. The aerosols were obtained using oxygen flow nebulizers with aerosols' generators Ultra Vent (Malinkrodt) and Venticis II (CIS bio international) that enabled as to get submicron particles. Oxygen flow between 9 and 11 liters per minute was used. Optimum images were obtained with 1480 MBq of inhaled aerosols at least 2 to 3 minutes. DTPA that was used for aerosols labeling had been produced in our Department and the results were compared with DTPA provided by CIS bio international. High correlation between both agents was proven. During the whole study ex tamper prepared radiopharmaceuticals were used and quality control was done using paper chromatography method. Acquisition was done in sitting position with gamma camera interfaced to a ADAC and Scintiview. The measurements lasted for 20 minutes. Data were stored on 64x64 matrices. Regions of interest over both lungs were drown and each one was divided in three segments: apical, medial, and basal. Using computer program curves of 99m Tc-DTPA lung clearance were derived. From the obtained time activity curves half-time of the global and the regional lung clearance was assessed. In the control group comprised of 32 healthy volunteers (non-smokers) we had got values, used after works as reference range. Our normal values for global clearance are: 68±5,5 min. for left whole lung, 68,1±6,5 min for right whole lung, and 49±7,7 min for apical, 66,9±8 min for middle, and 75,9±6,4 min basal regional lung clearance, and they are in keeping with the

  18. Improving accuracy of ET measurement of LISS nozzle to calandria tube clearance

    International Nuclear Information System (INIS)

    Craig, S.T.; Krause, T.W.; Schankula, J.J.

    2006-01-01

    The AECL Fuel Channel Inspection System (AFCIS) has been used in an in-reactor field trial to successfully measure the clearance between Liquid Injection Shutdown System (LISS) nozzles and calandria tubes. Each measurement over the full length of a channel added only 15 minutes to the on-channel inspection time. No changes were required to the inspection heads. The only equipment changes made were the addition of a Remote Field Eddy Current (RFEC) module to the eddy current instrument, and minor wiring changes, at the instrument, to achieve a RFEC configuration. With the experience gained from the field trial, factors potentially limiting accuracy were identified. These, and other factors, were investigated and are discussed herein. The RFEC probe is delivered inside the pressure tube. Magnetic fields from the RFEC probe extend through the conducting walls of the pressure tube and calandria tube to interact with the LISS nozzle. Data acquired during the field trial showed the LISS nozzle signal is distinct and the signal-to-noise ratio is very favourable. Nevertheless, comparison of the RFEC measurements to a visual examination, made during the same outage, had the RFEC method underestimating the clearance by 2.5 mm on average. By way of laboratory tests, the following factors were investigated as potential sources of error: resistivity and geometry of LISS nozzle reference/calibration pieces, pressure-tube wall thickness, diameter and resistivity variations, pressure-tube to calandria-tube gap, and radial offsets of the probe within the pressure-tube. The sensitivity to these various noise sources was established. A model, based on fundamental electromagnetic principles, was developed and was used to normalize the effects of LISS nozzle conductivity and geometry. This enabled compensation for various sources of error, and made it possible to produce a correction factor for the field trial data, reducing the average difference from the visual inspection of LISS

  19. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  20. Measurement of renal blood flow by phase-contrast magnetic resonance imaging during septic acute kidney injury: a pilot investigation.

    Science.gov (United States)

    Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo

    2012-06-01

    In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in

  1. In situ method for measurements of community clearance rate on shallow water bivalve populations

    DEFF Research Database (Denmark)

    Hansen, Benni W.; Dolmer, Per; Vismann, Bent

    2011-01-01

    An open-top chamber was designed for measuring ambient community clearance rate on undisturbed bivalve populations in the field. The chamber was pressed 5-10 cm down in the sediment on the mussel bed. It holds approximately 30-40 cm water column equal to a volume of 43-77 L. It was provided...... with an air lift connected to a SCUBA diver pressure tank generating a continuous and gentle water circulation. This ensures a complete mixture of suspended particles, and thereby, a maximum filtration by the bivalves. An in situ fluorometer was mounted to record plant pigment reduction due to mussel...

  2. Dynamic clearance measure to evaluate locomotor and perceptuo-motor strategies used for obstacle circumvention in a virtual environment.

    Science.gov (United States)

    Darekar, Anuja; Lamontagne, Anouk; Fung, Joyce

    2015-04-01

    Circumvention around an obstacle entails a dynamic interaction with the obstacle to maintain a safe clearance. We used a novel mathematical interpolation method based on the modified Shepard's method of Inverse Distance Weighting to compute dynamic clearance that reflected this interaction as well as minimal clearance. This proof-of-principle study included seven young healthy, four post-stroke and four healthy age-matched individuals. A virtual environment designed to assess obstacle circumvention was used to administer a locomotor (walking) and a perceptuo-motor (navigation with a joystick) task. In both tasks, participants were asked to navigate towards a target while avoiding collision with a moving obstacle that approached from either head-on, or 30° left or right. Among young individuals, dynamic clearance did not differ significantly between obstacle approach directions in both tasks. Post-stroke individuals maintained larger and smaller dynamic clearance during the locomotor and the perceptuo-motor task respectively as compared to age-matched controls. Dynamic clearance was larger than minimal distance from the obstacle irrespective of the group, task and obstacle approach direction. Also, in contrast to minimal distance, dynamic clearance can respond differently to different avoidance behaviors. Such a measure can be beneficial in contrasting obstacle avoidance behaviors in different populations with mobility problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Turbine-blade tip clearance and tip timing measurements using an optical fiber bundle sensor

    Science.gov (United States)

    Garcia, Iker; Beloki, Josu; Zubia, Joseba; Durana, Gaizka; Aldabaldetreku, Gotzon

    2013-04-01

    Traditional limitations of capacitive, inductive or discharging probe sensor for tip timing and tip clearance measurements are overcome by reflective intensity modulated optical fiber sensors. This paper presents the signals and results corresponding to a one stage turbine rig which rotor has 146 blades, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on turbine casing. It is composed of a central illuminating fiber that guides the light from a laser to the turbine blade, and two concentric rings of receiving fibers that collect the reflected light. Two photodetectors turn this reflected light signal from the receiving rings into voltage. The electrical signals are acquired and saved by a high-sample-rate oscilloscope. In tip clearance calculations the ratio of the signals provided by each ring of receiving fibers is evaluated and translated into distance. In the case of tip timing measurements, only one of the signals is considered to get the arrival time of the blade. The differences between the real and theoretical arrival times of the blades are used to obtain the deflections amplitude. The system provides the travelling wave spectrum, which presents the average vibration amplitude of the blades at a certain nodal diameter. The reliability of the results in the turbine rig testing facilities suggests the possibility of performing these measurements in real turbines under real working conditions.

  4. Renal function and plasma dabigatran level measured at trough by diluted thrombin time assay

    Directory of Open Access Journals (Sweden)

    Marta E. Martinuzzo

    2017-02-01

    Full Text Available Dabigatran etexilate (direct thrombin inhibitor is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc, correlate cc with classic coagulation assays, prothrombin time (PT and activated partial thromboplastin time (APTT, and evaluate them according to the creatinine clearance (CLCr. Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation receiving dabigatran at 150 (n = 19 or 110 (n = 21 mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL. PT and APTT (IL were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL. DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients' cc: median 83 (4-945 ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min showed significantly higher median cc: 308 (49-945, compared to the average 72 (12-190 and highest tertile, 60 (4-118 ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies

  5. Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

    Science.gov (United States)

    Barranger, John P.

    1993-01-01

    Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

  6. [Renal length measured by ultrasound in adult mexican population].

    Science.gov (United States)

    Oyuela-Carrasco, J; Rodríguez-Castellanos, F; Kimura, E; Delgado-Hernández, R; Herrera-Félix, J P

    2009-01-01

    Renal length estimation by ultrasound is an important parameter in clinical evaluation of kidney disease and healthy donors. Changes in renal volume may be a sign of kidney disease. Correct interpretation of renal length requires the knowledge of normal limits, these have not been described for Latin American population. To describe normal renal length (RL) by ultrasonography in a group of Mexican adults. Ultrasound measure of RL in 153 healthy Mexican adults stratified by age. Describe the association of RL to several anthropometric variables. A total of 77 males and 76 females were scanner. The average age for the group was 44.12 +/- 15.44 years. The mean weight, body mass index (BMI) and height were 68.87 +/- 11.69 Kg, 26.77 +/- 3.82 kg/m2 and 160 +/- 8.62 cm respectively. Dividing the population by gender, showed a height of 166 +/- 6.15 cm for males and 154.7 +/- 5.97 cm for females (p =0.000). Left renal length (LRL) in the whole group was 105.8 +/- 7.56 mm and right renal length (RRL) was 104.3 +/- 6.45 mm (p = 0.000.) The LRL for males was 107.16 +/- 6.97 mm and for females was 104.6 +/- 7.96 mm. The average RRL for males was 105.74 +/- 5.74 mm and for females 102.99 +/- 6.85 mm (p = 0.008.) We noted that RL decreased with age and the rate of decline accelerates alter 60 years of age. Both lengths correlated significantly and positively with weight, BMI and height. The RL was significantly larger in males than in females in both kidneys (p = 0.036) in this Mexican population. Renal length declines after 60 years of age and specially after 70 years.

  7. Quantitative metacarpal bone measurements before and after renal transplantation

    International Nuclear Information System (INIS)

    Andresen, J.; Nielsen, H.E.; Kommunehospitalet, Aarhus

    1986-01-01

    The outer (D) and inner diameter (d) of the second metacarpal bone, the combined cortical thickness (D-d), cortical area (D 2 -d 2 ) and bone mass ((D 2 d 2 /D 2 ) were measured in 74 renal transplant (RT) recipients at the time of renal transplantation and in a prospective analysis of 60 recipients after transplantation. The RT patient group was made up of recipients who after renal transplanation developed osteonecrosis or spontaneous fractures (RT-ON/SF) and an age- and sex-matched renal control group of subjects who did not develop these complications (RT-C). At the time of renal transplantation, in renal transplant recipient men and women, significantly reduced values in D, D-d and D 2 -d 2 was noticed. These findings could be explained by a higher ratio of bone resoprtion than formation at the periosteal surface. Following renal transplantation, significant increases in d were seen with significant decreases in D-d, D 2 -d 2 and (D 2 -d 2 )/D 2 , probably due to endosteal bone resorption, whereas D was unchanged compared with normal control persons. In the total group and in RT-ON/SF women, D decreased significantly and in ON/SF, increased significantly with significant decrease in bone mass compared with normal women whereas no significant changes in the parameters were seen in RT-C women. These findings indicate that bone loss after transplantation continues at the periosteal surface in women. The bone loss was most markedly demonstrated in women, who subsequently develop osteonecrosis or spontaneous fractures, probably due to combined periosteal and endosteal resorption of calcified bony tissue. (orig.)

  8. Renal haemodynamics, sodium and water reabsorption during continuous intravenous infusion of recombinant interleukin-2

    DEFF Research Database (Denmark)

    Geertsen, P F; von der Maase, H; Olsen, Niels Vidiendal

    1998-01-01

    1. Renal haemodynamics, lithium and sodium clearance were measured in 14 patients treated with recombinant interleukin-2 for metastatic renal cell carcinoma. 2. Patients were studied before and after 72 h of continuous intravenous infusion of recombinant interleukin-2 (18x10(6) i.u..24 h-1.m-2) a...... effect. Changes in renal prostaglandin synthesis may contribute to the decrease in renal blood flow. The lithium clearance data suggest that an increased proximal tubular reabsorption rate may contribute to the decreased sodium clearance during recombinant interleukin-2 treatment....

  9. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  10. Relationship between the thickness of the renal cortex and age: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian

    2004-01-01

    Objective: To study the relationship between the renal cortical thickness and age, and to establish the range of the normal renal cortex thickness by using CT measurement in different age groups so as to obtain a best age-related and practicable method for clinical measurement. Methods: (1) the accuracy of measuring renal cortical thickness by CT was evaluated: 18 kidney resected due to renal neoplasm were studied and the cortical thickness of the normal part of these specimens was assessed. The difference between the renal cortical thickness of specimens and preoperative measurements of renal cortex of the same patient by contrast enhanced CT was analyzed statistically. (2) 120 patients without history of renal disease or long term usage of potentially renal toxic drugs or history of hypertension were examined by CT with indication (s) other than renal disease. All the patients were divided into 20-40, 41-60, and 61-80 year-old groups. The renal cortical and parenchymal thickness and renal size were measured in three CT sections. The difference of the measurements among the three groups and their relationship to age was analyzed statistically. Results: There was no significant difference between the renal cortical thickness measured by enhanced spiral CT and measured in renal specimens (t=0.80, P=0.43). The renal cortical thickness in three groups was 0.73 cm, 0.65 cm, and 0.53 cm, respectively, and the differences among the three groups were significant (F=93.430, P 0.05). Conclusion: The measurement of the renal cortical thickness with enhanced spiral CT was reliable and was a sensitive method in investigating the morphologic changes of the kidney. The renal cortical thickness of normal kidney diminishes with age, but the change of the ratio of thickness of renal cortex to renal parenchyma with age was not significant

  11. Renal cortical volume measured using automatic contouring software for computed tomography and its relationship with BMI, age and renal function

    International Nuclear Information System (INIS)

    Muto, Natalia Sayuri; Kamishima, Tamotsu; Harris, Ardene A.; Kato, Fumi; Onodera, Yuya; Terae, Satoshi; Shirato, Hiroki

    2011-01-01

    Purpose: To evaluate the relationship between renal cortical volume, measured by an automatic contouring software, with body mass index (BMI), age and renal function. Materials and methods: The study was performed in accordance to the institutional guidelines at our hospital. Sixty-four patients (34 men, 30 women), aged 19 to 79 years had their CT scans for diagnosis or follow-up of hepatocellular carcinoma retrospectively examined by a computer workstation using a software that automatically contours the renal cortex and the renal parenchyma. Body mass index and estimated glomerular filtration rate (eGFR) were calculated based on data collected. Statistical analysis was done using the Student t-test, multiple regression analysis, and intraclass correlation coefficient (ICC). Results: The ICC for total renal and renal cortical volumes were 0.98 and 0.99, respectively. Renal volume measurements yielded a mean cortical volume of 105.8 cm 3 ± 28.4 SD, mean total volume of 153 cm 3 ± 39 SD and mean medullary volume of 47.8 cm 3 ± 19.5 SD. The correlation between body weight/height/BMI and both total renal and cortical volumes presented r = 0.6, 0.6 and 0.4, respectively, p < 0.05, while the correlation between renal cortex and age was r = -0.3, p < 0.05. eGFR showed correlation with renal cortical volume r = 0.6, p < 0.05. Conclusion: This study demonstrated that renal cortical volume had a moderate positive relationship with BMI, moderate negative relationship with age, and a strong positive relationship with the renal function, and provided a new method to routinely produce volumetric assessment of the kidney.

  12. Renal blood flow and metabolism after cold ischaemia: peroperative measurements in patients with calculi

    DEFF Research Database (Denmark)

    Petersen, H K; Henriksen, Jens Henrik Sahl

    1984-01-01

    Peroperative measurements of renal blood flow (RBF), renal O2-uptake, and renal venous lactate/pyruvate (L/P) ratio were performed before and after a period of 30-71 min of hypothermic (10-15 degrees C) renal ischaemia in nine patients, undergoing surgery for renal calculi. Before ischaemia, RBF.......01) immediately after re-established perfusion and 36% (P less than 0.02) 30 min later. In one additional patient, who had a short warm ischaemia (8 min), the flow pattern was the same. As arterial pressure remained constant, the reduced RBF signifies an increased renal vascular resistance. Renal O2-uptake...... and renal venous L/P ratio were almost constant, indicating no significant anaerobic processes being involved in the flow response. None of the patients showed any signs of reactive hyperaemia. It is concluded that hypothermic renal ischaemia may be followed by an increased renal vascular resistance even...

  13. The mythology of renal function measurement

    International Nuclear Information System (INIS)

    Britton, K.E.

    2003-01-01

    The kidney is a conservative organ. In principle it retains what the body needs, and what is not needed is excreted. It has a number of basic properties. It has the ability to take solutes up from the blood whether by filtration or secretion, which is best called its Uptake function. In the special circumstance where the kidneys are the only exit for the solute from the body, then the rate of loss from the blood is equal to the rate of uptake by the kidney. It has the ability to move solutes among its nephrons, which is its Transit function. The solutes may be absorbed in whole or part and be retained or returned to the blood, its Reabsorption function. In the special case where the solute is non- reabsorbable, then, if there is an increase in salt and water reabsorption as in functionally significant renovascular disease or obstructive nephropathy, the transit function is altered and the transit time through the parenchyme is prolonged. In renovascular disorder the transit time is prolonged through both cortical and juxta-medullary nephrons and collecting ducts. In obstructive nephropathy the transit time is prolonged through the cortical nephrons, but usually is shortened through the juxta-medullary nephrons and collecting ducts due to loss of medullary concentrating ability. After transit through the kidney, the solutes move through the pelvis and ureter, its Excretory function. No more can come out of the kidney then went in previously. If less comes out than what went in, then an increased resistance to outflow is predicted. The balance between excretory function and uptake function is measurable by the Output (Outflow) Efficiency. The kidney also has receptors for hormones, which may modify its reabsorptive functions, for example increased Vasopressin binding decreases the permeability of the collecting duct to water. The kidney also has the ability through enzymes to modify solutes, such as the activation of Vitamin D

  14. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  15. Tip-Clearance Measurement in the First Stage of the Compressor of an Aircraft Engine

    Directory of Open Access Journals (Sweden)

    Iker García

    2016-11-01

    Full Text Available In this article, we report the design of a reflective intensity-modulated optical fiber sensor for blade tip-clearance measurement, and the experimental results for the first stage of a compressor of an aircraft engine operating in real conditions. The tests were performed in a ground test cell, where the engine completed four cycles from idling state to takeoff and back to idling state. During these tests, the rotational speed of the compressor ranged between 7000 and 15,600 rpm. The main component of the sensor is a tetrafurcated bundle of optical fibers, with which the resulting precision of the experimental measurements was 12 µm for a measurement range from 2 to 4 mm. To get this precision the effect of temperature on the optoelectronic components of the sensor was compensated by calibrating the sensor in a climate chamber. A custom-designed MATLAB program was employed to simulate the behavior of the sensor prior to its manufacture.

  16. Measurement of hepatic blood flow in the unanesthetized rabbit using 198Au and 125I rose bengal clearance technique

    International Nuclear Information System (INIS)

    Balabaud, C.; Roche, M.-C.; Dangoumau, Jacques

    1975-01-01

    Hepatic blood flow was measured in the unanesthetized rabbit using the clearance technique of 198 Au and 125 I RB. The values are: 71.82+-16.24ml.min -1 .kg -1 for 198 Au, and 60.21+-9.94ml.min -1 .kg -1 for 125 I RB (P 198 Au [fr

  17. Optical Tip Clearance Measurements as a Tool for Rotating Disk Characterization

    Directory of Open Access Journals (Sweden)

    Iker García

    2017-01-01

    Full Text Available An experimental investigation on the vibrational behavior of a rotating disk by means of three optical fiber sensors is presented. The disk, which is a scale model of the real disk of an aircraft engine, was assembled in a wind tunnel in order to simulate real operation conditions. The pressure difference between the upstream and downstream sides of the disk causes an airflow that might force the disk to vibrate. To characterize this vibration, a set of parameters was determined by measuring the tip clearance of the disk: the amplitude, the frequency and the number of nodal diameters in the disk. All this information allowed the design of an upgraded prototype of the disk, whose performance was also characterized by the same method. An optical system was employed for the measurements, in combination with a strain gauge mounted on the disk surface, which served to confirm the results obtained. The data of the strain gauge coincided closely with those provided by the optical fiber sensors, thus demonstrating the suitability of this innovative technique to evaluate the vibrational behavior of rotating disks.

  18. Treatment, decontamination and clearance measurement of ERAM installations in preparation of its decommissioning

    International Nuclear Information System (INIS)

    Gassmann, S.; Schulze, H.

    2001-01-01

    In the final repository for radioactive waste Morsleben (ERAM) disposal of loose solid waste and conditioning of liquid waste were performed beside the method of simply piling of usual in trade packages. At such a handling of unsealed radioactive material there is a possibility of contamination. Accordingly the operational and radiation protection regime is focused to the contamination occurrence and control. In preparation of the planned decommissioning of the ERAM all potential contamination were recorded, considered due to their cause and verified due to their extent, distribution and nuclide composition. Therefor corresponding measurement programmes have been performed. The dominant nuclide is Cs-137 as expected. Co-60 and the pure beta emitter Sr-90 are present too in a not negligible dimension. To eliminate the aboveground contamination is an objective while operation as well as while decommissioning work. Therefore corresponding clearance measurements have to be performed. Underground traces of radioactivity as surface contamination outside the final disposal cavities have no meaning for long term safety. This activity share is included already in the repository inventory. Underground contaminated material should remain there. Radioactive liquid residues must be fixed. (orig.)

  19. Determination of hepatic fractional clearance of radioactive gold colloids for a measure of effective hepatic blood flow

    International Nuclear Information System (INIS)

    Fujii, Masahiro

    1979-01-01

    For a measure of effective blood flow, a hepatic fractional clearance of 198 Au-colloids was determined, which was obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic uptake was determined with a gamma camera. The counts over the liver was corrected for body weight and height. The method was considered sufficiently simple for routine use. 198 Au-colloids were obtained from Dainabot Lab. and CIS. The former gave 64% higher values of disappearance rate than the latter, without any change in the organ distribution. A quality control tests were applied over a six-year period to the disappearance rates. Reproducibility within 95 to confidence limits was found for both groups. In 28 normal control subjects, hepatic fractional clearance of the colloids from Dainabot Lab. was 18.5 +- 3.4%/min. In patients with progressed hepatic disease, both hepatic fractional clearance and final hepatic uptake were decreased, showing that the determination of hepatic uptake is necessary in measuring effective hepatic blood flow by the colloidal clearance method. The influence of splenic uptake is discussed in relation to hepatic blood flow measurement. (author)

  20. Monoexponential analysis of plasma disappearance of 99mTc-DTPA and 131I-iodohippurate: A reliable method for measuring changes of renal function

    International Nuclear Information System (INIS)

    Clifton, G.G.; Anderson, C.; McMahon, G.; Vargas, R.; Wallin, J.D.

    1989-01-01

    Glomerular filtration rate and effective renal plasma flow were measured in 170 subjects using monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after single injection. In the current study population, glomerular filtration rate and effective renal plasma flow decreased with increasing age, were less in females than in males, and were less in hypertensives than in normotensives. Differences in glomerular filtration rate according to age and sex in the current study were similar to those reported using traditional creatinine clearance methodology. Monoexponential treatment of plasma isotope disappearance gave reproducible values for both glomerular filtration rate and effective renal plasma flow when measured either during the day or on a daily basis. Intraindividual coefficient of variation was less than 10% for both 99m Tc-DTPA and 131 I-iodohippurate clearances derived from monoexponential analysis. These results demonstrate that monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after a single injection is a useful method for evaluating changes in renal hemodynamics either during chronic drug therapy or acutely after single dose administration

  1. Reproducibility of estimation of blood flow in the human masseter muscle from measurements of 133Xe clearance

    International Nuclear Information System (INIS)

    Monteiro, A.A.; Kopp, S.

    1989-01-01

    The reproducibility of estimations of the masseter intramuscular blood flow (IMBF) was assessed bilaterally within and between clinical sessions. The 133 Xe clearance in nine normal individuals was measured before, during, and immediately after endurance of isometric contraction at an attempted level of 50% of maximum voluntary clenching contraction. An overall low reproducibility of the estimations was found. This result was probably caused by uncertainties about the excact site of intramuscular 133 Xe deposition, errors in assessment of the plots of clearance, and variabilities in the relative contraction levels sustained, especially in the overall muscle effort. In agreement with previous reports concerning other skeletal muscles, the 133 Xe clearance method provided inconsistent estimates of absolute values of IMBF also in this clinical setting. Although there was a high intra-individual variation in the relative level of isometric contraction sustained, the endurance test induced distinct changes in IMBF, among which the estimate of post-endurance hyperemia was the most consistent for each individual. Therefore, measurements of 133 Xe clearance seem to be useful to detect intra-induvidual changes in masseter IMBF resulting from isometric work. 21 refs

  2. Carbamazepine and carbamazepine-10,11-epoxide clearance measurements during continuous venovenous hemofiltration in a massive overdose.

    Science.gov (United States)

    Smollin, Craig Geoffrey; Petrie, Matthew S; Kearney, Thomas

    2016-06-01

    Carbamazepine (CBZ) overdose can result in significant neurologic and cardiovascular toxicity, and is compounded by the presence of an active metabolite, carbamazepine-10,11-epoxide (CBZE). Existing publications describing continuous venovenous hemofiltration (CVVH) in CBZ overdose are limited in their ability to calculate accurate clearances. We report a case of CBZ overdose treated with CVVH with detailed measurement of CBZ, CBZE and their respective clearances calculated utilizing serial effluent measurements. This was coupled with serum level determinations comparing two analytical methodologies, time-of-flight mass spectroscopy and an immunoassay. A 41-year-old woman presented unresponsive after an overdose of CBZ. Initial CBZ serum levels were markedly elevated (57.8 μg/mL) and continued to rise. Due to continued hemodynamic instability, extracorporeal removal was initiated using CVVH. During the first 30 h of CVVH, interval serum samples and all ultrafiltrate bags were collected and analyzed. Serum and effluent levels of CBZ and CBZE were measured using an Agilent 6230 time-of-flight high-resolution mass spectrometer (TOF-MS). CBZ levels were also obtained utilizing the Microgenics CEDIA Carbamazepine Immunoassay (Thermo Fisher, Waltham, MA) for serum and effluent samples. Immunoassay analysis was performed using Siemens ADVIA 1800 instrument. The clearances achieved for CBZE (mean = 25.2, range 17.7-42.6 mL/min) exceeded that for CBZ (mean = 18.1, range 12.7-28.7 mL/min). CVVH removed a total of 1293 and 1261 mg of CBZ and CBZE, respectively. Serum levels of CBZ measured by immunoassay when compared with TOF-MS indicated cross reactivity of CBZE with the immunoassay. CVVH removed CBZE with higher clearances than CBZ. However, CVVH clearance rates for both CBZ and CBZE were lower than published clearances of CBZ and CBZE by intermittent hemodialysis. Our methodology allowed for a precise pharmacokinetic assessment of clearance based on

  3. Measurement of renal index on X-CT

    International Nuclear Information System (INIS)

    Iguchi, Takashi

    1991-01-01

    Morphological measurements of the kidney were made using X-CT images. Anteroposterior (AP) width of the kidney as well as the renal sinus on both right and left sides and the transverse width of the first lumbar vertebral body were measured from CT images. Changes according to age in AP width of the kidney and the transverse width of the lumbar vertebral body were investigated. As to the ratio of the AP width of the kidney (both right and left) to the transverse width of the lumbar vertebral body, and the ratio of the AP width of the kidney to the AP width of the renal sinus, the changes due to aging and the differences between male and female were studied. The average AP width of the right kidney was 47 mm, while that of the left kidney was 49 mm. The left kidney was slightly larger than the right kidney with statistical significance. In subjects up to 19 years of age, both the AP width of the kidney and the transverse width of the lumbar vertebral body showed correlation with age, while after the age of 20, there was no age-related correlation. The average ratio of the AP width of the kidney to the transverse width of the lumbar vertebral body was 1.13 for the right kidney and 1.19 for the left kidney. The difference between those two items was statistically significant and the changes due to aging were slight. During the age between 4 and 64 years, they were constant and no significant change was noticed. No difference between male and female was found. From the age of 65 years, a decreasing tendency was noticed. The ratios of AP width of the kidney to the AP width of renal sinus for both kidneys in males and females were found to be inversely correlated with age. They were similar to the changes due to aging in renal functions of the cortex system. On CT images, the ratio of AP width could be the index of both the size of the kidney and the thickness of the renal parenchyma respectively. (author)

  4. Clinical significance of measurement of changes of plasma leptin and serum NPY levels after hemodialysis in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Xia Zhengping

    2010-01-01

    Objective: To explore the clinical significance of changes of plasma leptin and serum NPY levels after hemodialysis in patients with chronic renal failure. Methods: Plasma leptin and serum NPY levels were measured with RIA both before and after hemodialysis in 31 patients with chronic renal failure as well as in 35 controls. Results: Before hemodialysis,plasma leptin and serum NPY levels were significantly higher in the patients than those in controls (P<0.01). After hemodialysis for 1 week the levels, though dropped markedly, still remained significantly higher than those in controls (P<0.05). Conclusion: The levels of leptin and NPY were significantly increased in patients with chronic renal failare. Hemodialysis could increase, the clearance rate of leptin and NPY and partially correct the levels with important clinical value. (authors)

  5. Renal Blood Flow, Glomerular Filtration Rate, and Renal Oxygenation in Early Clinical Septic Shock.

    Science.gov (United States)

    Skytte Larsson, Jenny; Krumbholz, Vitus; Enskog, Anders; Bragadottir, Gudrun; Redfors, Bengt; Ricksten, Sven-Erik

    2018-06-01

    Data on renal hemodynamics, function, and oxygenation in early clinical septic shock are lacking. We therefore measured renal blood flow, glomerular filtration rate, renal oxygen consumption, and oxygenation in patients with early septic shock. Prospective comparative study. General and cardiothoracic ICUs. Patients with norepinephrine-dependent early septic shock (n = 8) were studied within 24 hours after arrival in the ICU and compared with postcardiac surgery patients without acute kidney injury (comparator group, n = 58). None. Data on systemic hemodynamics and renal variables were obtained during two 30-minute periods. Renal blood flow was measured by the infusion clearance of para-aminohippuric acid, corrected for renal extraction of para-aminohippuric acid. Renal filtration fraction was measured by renal extraction of chromium-51 labeled EDTA. Renal oxygenation was estimated from renal oxygen extraction. Renal oxygen delivery (-24%; p = 0.037) and the renal blood flow-to-cardiac index ratio (-21%; p = 0.018) were lower, renal vascular resistance was higher (26%; p = 0.027), whereas renal blood flow tended to be lower (-19%; p = 0.068) in the septic group. Glomerular filtration rate (-32%; p = 0.006) and renal sodium reabsorption (-29%; p = 0.014) were both lower in the septic group. Neither renal filtration fraction nor renal oxygen consumption differed significantly between groups. Renal oxygen extraction was significantly higher in the septic group (28%; p = 0.022). In the septic group, markers of tubular injury were elevated. In early clinical septic shock, renal function was lower, which was accompanied by renal vasoconstriction, a lower renal oxygen delivery, impaired renal oxygenation, and tubular sodium reabsorption at a high oxygen cost compared with controls.

  6. Dynamics of formation and resolution of vasogenic brain oedema. 1. Measurement of oedema clearance into ventricular CSF

    Energy Technology Data Exchange (ETDEWEB)

    Tsuyumu, M; Reulen, H J; Prioleau, G [Mainz Univ. (Germany, F.R.). Neurochirurgische Klinik

    1981-01-01

    Previous studies showed that resolution of brain oedema may occur by clearance into the CSF. The present study was performed to measure quantitatively the amount of oedema clearance in cold-induced oedema in cats. In order to determine the minute amounts of oedema fluid entering the CSF the oedema fluid was labelled with a high concentration of an extracellular marker (S/sup 35/-sodiumthiosulphate). Ventriculo-cisternal perfusion was used to collect the marker in the cisternal outflow. By using the assumption that oedema fluid has the same marker concentration as the plasma, the distribution profile of extracellular space as well as the clearance rate of oedema into CSF could be computed. Oedema and thiosulphate space were most pronounced in the white matter underlying the cortical cold injury. The values then declined progressively with the distance from the lesion towards the ventricle. Oedema fluid clearance into the ventricular CSF at 24 hours following the cold injury amounted to 0.8-1.2 ..mu..l/min or 1.15 ml/day. These data support the assumption that this may be one of the main mechanisms of the resolution of vasogenic brain oedema.

  7. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by 133Xe clearance technique

    International Nuclear Information System (INIS)

    Basa, S.; Ercan, M.T.; Aras, T.; Araz, K.

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of 133 Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), 133 Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2±12.9 and 58.3±3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4±3.2 and 21.7±15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2±16.9 ml/100 g/min) and above (63.9±9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing. (author)

  8. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  9. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  10. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  11. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  12. A comparison of two nuclear-medical techniques for effective renal plasma flow determination in rabbits: Radiation controlled infusion-pump and whole-body measurement according to Oberhausen

    International Nuclear Information System (INIS)

    Mayer-Wehrstein, R.

    1981-01-01

    Two nuclear techniques were investigated for determination of the effective renal plasma flow with J-131-Hippuran in rabbits: whole-body measurement according to Oberhausen and clearance determination with a radiation controlled feed back infusion pump. In the first method the clearance determination follows after a single injection of the testing substance in the decreasing phase of the blood level, in the second method a constant blood level of the testing substance is maintained. A technique was developed for the determination of the blood-tissue ratio by considering the values determined by the constant blood level. This way the exact clearance values were computet for the decreasing plasma level. Nineteen clearance determinations were performed in rabbits altogether. (orig.) [de

  13. Effect of kefir and low-dose aspirin on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet.

    Science.gov (United States)

    Kanbak, Güngör; Uzuner, Kubilay; Kuşat Ol, Kevser; Oğlakçı, Ayşegül; Kartkaya, Kazım; Şentürk, Hakan

    2014-01-01

    Abstract We aim to study the effect of low-dose aspirin and kefir on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet. Forty adult male Sprague-Dawley rats were divided into five groups: control, high-salt (HS) (8.0% NaCl), HS+aspirin (10 mg/kg), HS+kefir (10.0%w/v), HS+aspirin +kefir. We measured sistolic blood pressure (SBP), mean arterial pressure (MAP), diastolic pressure, pulse pressure in the rats. Cathepsin B, L, DNA fragmentation and caspase-3 activities were determined from rat kidney tissues and rats clearance of creatinine calculated. Although HS diet increased significantly SBP, MAP, diastolic pressure, pulse pressure parameters compared the control values. They were not as high as accepted hypertension levels. When compared to HS groups, kefir groups significantly decrease Cathepsin B and DNA fragmentation levels. Caspase levels were elevated slightly in other groups according to control group. While, we also found that creatinine clearance was higher in HS+kefir and HS+low-dose aspirin than HS group. Thus, using low-dose aspirin had been approximately decreased of renal function damage. Kefir decreased renal function damage playing as Angiotensin-converting enzyme inhibitor. But, low-dose aspirin together with kefir worsened rat renal function damage. Cathepsin B might play role both apoptosis and prorenin-processing enzyme. But not caspase pathway may be involved in the present HS diet induced apoptosis. In conclusion, kefir and low-dose aspirin used independently protect renal function and renal damage induced by HS diet in rats.

  14. Late renal function after upper abdominal irradiation

    International Nuclear Information System (INIS)

    Morris, Monica M.; Willett, Christopher G.

    1997-01-01

    Purpose: This study assesses the late renal function and complications following upper abdominal irradiation. Methods and Materials: Eighty-six adult patients were identified who were treated with curative intent to the upper abdomen, received greater than 50% unilateral kidney irradiation to doses of at least 26 Gy, and survived for 1 year or more. Following treatment, the clinical course, blood pressure, addition of anti-hypertensive medications, serum creatinine and creatinine clearance were determined. Creatinine clearance was calculated by the formula: creatinine clearance equals [(140 - age) x (weight in kilograms)] / (72 x serum creatinine), which has a close correlation to creatinine clearances measured by 24 hour urine measurement. The percent change in creatinine clearance from pre-treatment values was analyzed. Mean follow-up was 6.7 years. Seventeen patients were followed for 11 or more years. Results: Of the 16 patients with pre-radiotherapy hypertension, eight required an increase in the number of medications for control and eight required no change in medication. Twenty-one patients developed hypertension in follow-up, 15 of whom required no medication. One patient developed malignant hypertension on the basis of renal artery stenosis. Acute or chronic renal failure was not observed in any patient. The serum creatinine for all 86 patients prior to irradiation was below 2 mg/100 ml; in follow-up it rose to between 2-3 mg/100 ml in five patients. On univariate analysis, older patient age, female sex, pre-existing hypertension and initially abnormal renal function (creatinine clearance <90mg/ml) were significantly correlated with later poor creatinine clearance (<50 mg/ml). Conclusions: After significant unilateral kidney irradiation, patients demonstrated a laboratory trend to increased creatinine and decreased creatinine clearance. With long-term follow-up, these physiologic changes did not appear to translate into a clinically relevant alteration in

  15. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, L; Henriksen, Jens Henrik Sahl

    1989-01-01

    , whereas the difference was very sensitive to even small changes in forearm blood flow within the physiological range. For measurement of renal plasma clearance it is recommended to use one long period: from the time of injection until 300 min p.i. or longer. If the clearance period is too short, the use...... introduced in the measurement of renal plasma clearance and total plasma clearance by using venous blood samples instead of arterial. In 13 patients with GFR ranging from 29 to 150 ml min-1, Ca was higher than Cv immediately after the injection. After mean 38 min (range 12-82 min) the two curves crossed...... of venous samples will overestimate the true renal clearance. Plasma clearance determined by venous and arterial blood samples does not differ significantly as long as the concentration is followed from the time of injection and a long period is applied. When simplified plasma clearance techniques are used...

  16. Correlation of glomerular filtration rate measurement using Tc-99m DTPA with cystatin-C levels and creatinine clearance for staging of chronic kidney disease

    International Nuclear Information System (INIS)

    Elliyanti, A.; Iskandar, Azmi S.

    2007-01-01

    Full text: The presence of Chronic Kidney Disease (CKD) was established based on kidney damage presence and the level of kidney function through Glomerular filtration rate (GFR). It was also recognized that renal scintigraphy (renogram) using TC-99m DTPA (diethylenetriamine pentacetic acid) has advantages in the measurement of GFR. Recently, serum Cystatin-C is proposed as the new marker of GFR. The aim of this study is to find out the correlation of GFR, derived from renogram, with Cystatin- C levels and Creatinine Clearance (CC) in CKD. Material and Methods: A total of 30 subjects (age mean is 60.8 years, 21 males and 9 females) were enrolled in this study with diagnosis stage 2 of CKD. CKD staging was determined by Cockroft-Gault (CG) equation, taking into account the serum creatinine. Renogram was performed using a single head camera with IV administration of 5 mCi DTPA. Cystatin-C and creatinine clearance (24-hours urine samples) were include in this study. Results: The mean GFR of renogram, Cystatin-C, CC and CG are 64.96 ml/min/1.73m2 (SD 28.047), 53.37 ml/min/1.73m2 (SD 21.29), 58.09 ml/min/1.73m2 (SD 35.45), 46.00 ml/min/1.73m2 (SD 12.06) respectively. There is better correlation between renogram and Cystatin-C (r=0.585, p0.0007) compared renogram and CC (r=0.388, p=0.03) or renogram and CG (r=-0.029, p=0.87). Conclusion: Cystatin-C shows better indicator of GFR than CC and CG. Serum creatinine concentration alone should not be used to assess the level of kidney function in the staging of CKD. (author)

  17. Radionuclide evaluation of renal transplants

    International Nuclear Information System (INIS)

    Yang Hong; Zhao Deshan

    2000-01-01

    Radionuclide renal imaging and plasma clearance methods can quickly quantitate renal blood flow and function in renal transplants. They can diagnose acute tubular necrosis and rejection, renal scar, surgical complications such as urine leaks, obstruction and renal artery stenosis after renal transplants. At the same time they can assess the therapy effect of renal transplant complications and can also predict renal transplant survival from early post-operative function studies

  18. Measurement of apolipoprotein E and amyloid β clearance rates in the mouse brain using bolus stable isotope labeling

    Science.gov (United States)

    2012-01-01

    Background Abnormal proteostasis due to alterations in protein turnover has been postulated to play a central role in several neurodegenerative diseases. Therefore, the development of techniques to quantify protein turnover in the brain is critical for understanding the pathogenic mechanisms of these diseases. We have developed a bolus stable isotope-labeling kinetics (SILK) technique coupled with multiple reaction monitoring mass spectrometry to measure the clearance of proteins in the mouse brain. Results Cohorts of mice were pulse labeled with 13 C6-leucine and the brains were isolated after pre-determined time points. The extent of label incorporation was measured over time using mass spectrometry to measure the ratio of labeled to unlabeled apolipoprotein E (apoE) and amyloid β (Aβ). The fractional clearance rate (FCR) was then calculated by analyzing the time course of disappearance for the labeled protein species. To validate the technique, apoE clearance was measured in mice that overexpress the low-density lipoprotein receptor (LDLR). The FCR in these mice was 2.7-fold faster than wild-type mice. To demonstrate the potential of this technique for understanding the pathogenesis of neurodegenerative disease, we applied our SILK technique to determine the effect of ATP binding cassette A1 (ABCA1) on both apoE and Aβ clearance. ABCA1 had previously been shown to regulate both the amount of apoE in the brain, along with the extent of Aβ deposition, and represents a potential molecular target for lowering brain amyloid levels in Alzheimer's disease patients. The FCR of apoE was increased by 1.9- and 1.5-fold in mice that either lacked or overexpressed ABCA1, respectively. However, ABCA1 had no effect on the FCR of Aβ, suggesting that ABCA1 does not regulate Aβ metabolism in the brain. Conclusions Our SILK strategy represents a straightforward, cost-effective, and efficient method to measure the clearance of proteins in the mouse brain. We expect that

  19. Development of a liquid chromatography tandem mass spectrometry method for iothalamate measurement to assess renal function for potential kidney donation.

    Science.gov (United States)

    Rhea, Jeanne M; Ritchie, James C; Molinaro, Ross J

    2013-05-01

    Chronic kidney disease often goes undetected due to the insensitivity of current methods to accurately assess glomerular filtration rate (GFR) in early stages of renal dysfunction. The clearance of exogenously introduced iothalamate, a commonly used radiopaque agent, is an alternative to inulin clearance for the assessment of renal function and its use in calculating GFR can serve as a screening tool for kidney transplant donors. A method was developed to measure iothalamate in plasma and urine samples by HPLC combined with electrospray positive ionization tandem mass spectrometry (MS/MS). Iothalamate is isolated from plasma by methanol extraction and urine using a quick-spin filtration approach, then monitored by multiple reaction monitoring using the hydrogen adduct mass transitions. Iohexol was used as an internal standard. Iothalamate was measured within an analytical run time of 5 min, with a lower limit of quantification of 18.75 ng/ml. The intraassay and interassay variations of the plasma and urine iothalamate assays were both calculated using the patient's urine flow rate and plasma and urine iothalamate values. Linear correlations tested by LC-MS/MS and an accepted capillary electrophoresis (CE) assay showed similar results (GFR, r=0.92, Sy/x=10.3). We developed and validated an LC-MS/MS method for quantitating iothalamate in plasma and urine to calculate GFR used for screening potential kidney donors in our hospital system. A less sensitive mass spectrometry system does not sacrifice analytical or clinical sensitivity for measuring GFR. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Effect of nitrendipine on renal function and on hormonal parameters after intravascular iopromide

    DEFF Research Database (Denmark)

    Madsen, J K; Jensen, J W; Sandermann, J

    1998-01-01

    PURPOSE: To evaluate the effect of the low-molecular nonionic radiographic contrast agent iopromide (Ultravist) on renal function, vasoactive peptides (angiotensin II, aldosterone, arginine vasopressin, and atrial natriuretic factor (ANF)), and blood pressure, and to evaluate the influence....... Renal tubular function was estimated from the clearance of lithium. Hormones were measured by radioimmunoassays. RESULTS: Arteriography with iopromide did not change renal function. No differences between the nitrendipine and placebo groups were found in renal hemodynamics, tubular sodium handling...

  1. The measurement of 99mTc-DTPA pulmonary clearance in normals, asymptomatic smokers and diabetic patients

    International Nuclear Information System (INIS)

    Kim, In Ju; Kim, Seong Jang; Kim, Yong Ki; Kim, Yun Seong; Lee, Min Ki; Park, Soon Kew

    1998-01-01

    We measured pulmonary epithelial permeability by 99m Tc-DTPA radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate 99m Tc-DTPA radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. We performed 99m Tc-DTPA radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). 99m Tc-DTPA clearance half-time (T 1/2 ) was calculated, then compared with the result of chest radiography and pulmonary function test. Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiophaty were significantly older (p 1/2 of normal subjects and asymptomatic smokers were significantly different (65.2±23.7 min vs 39.6±9.8 min, p 1/2 was 90.5±46.5 min and significantly delayed when compared with those of normals and asymptomatic smokers (p 1/2 of diabetic patients without microangiopathy, 70.0±12.7 min, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the T 1/2 and spirometric parameters including DLco, FVC, FEV 1 , FEV 1 /FVC (%) and FEF 25-75% in all subjects, and between the T 1/2 and duration of diabetes in diabetic patients. Eventhough the influence of age can't be excluded, delayed 99m Tc-DTPA clearance half-time (T 1/2 ) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy

  2. Renal function measured by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Boijsen, M.; Jacobsson, L.; Tylen, U.; Sahlgrenska Sjukhuset, Goeteborg

    1987-01-01

    In twenty-six patients injected with metrizoate during urography, plasma was analyzed for iodine concentration using X-ray fluorescence analysis, and total plasma clearance of contrast medium was calculated. Total plasma clearance of 51 Cr-EDTA was also determined, but not simultaneously, in order to find out if the urographic procedure would influence the kidneys to such an extent that the contrast medium clearance value would differ much from the 51 Cr-EDTA clearance value. The errors in the method were assessed and the total error of the contrast medium clearance determination was calculated. When comparing 51 Cr-EDTA and metrizoate clearance a correlation of 0.94 and a mean ratio of 1.046 (SD 0.138) was found. The assessable errors cannot fully explain the standard deviation, which might indicate a transient change in kidney function related to elements of the urographic procedure such as laxation with possible dehydration and/or the contrast medium dose. (orig.)

  3. Mercaptoacetyltriglycine diuretic renography and output efficiency measurement in renal transplant patients

    International Nuclear Information System (INIS)

    Spicer, S.T.; Chi, Ka-Kit; Larcos, G.; Farlow, D.C.; Choong, K.K.L.; Gruenewald, S.M.; Nankivell, B.J.; Chapman, J.R.

    1999-01-01

    Suspected urinary tract obstruction following renal transplantation presents a diagnostic dilemma. The purposes of this study were: (1) to establish a normal range of measurement of output efficiency (OE) in the renal transplant population, and (2) to assess prospectively the usefulness of OE in the setting of allograft obstruction. Twenty-two renal transplant patients with stable renal function and no evidence of hydronephrosis on serial ultrasound examination had a diuretic mercaptoacetyltriglycine scan with calculation of OE. Three renal transplant patients with confirmed graft obstruction were also studied. Standard qualitative and quantitative parameters as well as OE were calculated. The mean OE for the 22 normal renal transplant patients was 86.3%±3.7% (range: 77%-91%). OE values in the three obstructed patients were 59%, 68% and 75% respectively. It is concluded that OE should normally exceed 77% in renal graft recipients. OE is a promising means of diagnosing functional obstruction in these patients. (orig.)

  4. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  5. Renal effects of amino acids and dopamine in renal transplant recipients treated with or without cyclosporin A

    DEFF Research Database (Denmark)

    Hansen, J M; Olsen, Niels Vidiendal; Leyssac, P P

    1996-01-01

    1. The nephrotoxic effects of cyclosporin A may diminish the ability of the transplanted kidney to increase the glomerular filtration rate and effective renal plasma flow during infusion of dopamine or amino acids. 2. The present study included 16 renal transplant recipients transplanted for more...... and of dopamine in renal transplant recipients with a good graft function.......-creatinine, 89 +/- 6 mumol/l). The renal response to infusion of dopamine and of amino acids was investigated on two separate days. All clearance measurements were carried out at nadir cyclosporin A blood levels. 3. Effective renal plasma flow increased significantly in the non-cyclosporin A group...

  6. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    Science.gov (United States)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  7. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  8. Determination of representative renal depth for accurate attenuation corred in measurement of glomerular filtration rate in transplanted kidney

    International Nuclear Information System (INIS)

    Oh, Soon Nam; Kim, Sung Hoon; Rha, Sung Eun; Chung, Yong An; Yoo, Ie Ryung; Sohn, Hyung Sun; Lee, Sung Young; Chung, Soo Kyo

    2002-01-01

    To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured DFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depth under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are 4.09±0.65 cm in men, and 4.24±0.78 cm in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply

  9. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  10. MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

    Science.gov (United States)

    Wentland, Andrew L; Artz, Nathan S; Fain, Sean B; Grist, Thomas M; Djamali, Arjang; Sadowski, Elizabeth A

    2012-01-01

    Magnetic resonance imaging (MRI) may be a useful adjunct to current methods of evaluating renal function. MRI is a noninvasive imaging modality that has the ability to evaluate the kidneys regionally, which is lacking in current clinical methods. Other investigators have evaluated renal function with MRI-based measurements, such as with techniques to measure cortical and medullary perfusion, oxygen bioavailability and total renal blood flow (TRBF). However, use of all three techniques simultaneously, and therefore the relationships between these MRI-derived functional parameters, have not been reported previously. To evaluate the ability of these MRI techniques to track changes in renal function, we scanned 11 swine during a state of hyperperfusion with acetylcholine and a saline bolus and subsequently scanned during a state of hypoperfusion with the prolonged use of isoflurane anesthesia. For each time point, measurements of perfusion, oxygen bioavailability and TRBF were acquired. Measurements of perfusion and oxygen bioavailability were compared with measurements of TRBF for all swine across all time points. Cortical perfusion, cortical oxygen bioavailability, medullary oxygen bioavailability and TRBF significantly increased with the acetylcholine challenge. Cortical perfusion, medullary perfusion, cortical oxygen bioavailability and TRBF significantly decreased during isoflurane anesthesia. Cortical perfusion (Spearman's correlation coefficient = 0.68; P renal function. Maintenance of the medullary oxygen bioavailability in low blood flow states may reflect the autoregulation particular to this region of the kidney. The ability to non-invasively measure all three parameters of kidney function in a single MRI examination and to evaluate the relationships between these functional parameters is potentially useful for evaluating the state of the human kidneys in situ in future studies.

  11. The renal quantitative scintillation camera study for determination of renal function

    International Nuclear Information System (INIS)

    Thompson, I.M. Jr.; Boineau, F.G.; Evans, B.B.; Schlegel, J.U.

    1983-01-01

    The renal quantitative scintillation camera study assesses glomerular filtration rate and effective renal plasma flow based upon renal uptake of 99mtechnetium-iron ascorbate and 131iodine-hippuran, respectively. The method was compared to inulin, para-aminohippuric acid and creatinine clearance studies in 7 normal subjects and 9 patients with various degrees of reduced renal function. The reproducibility of the technique was determined in 15 randomly selected pediatric patients. The values of glomerular filtration rate and effective renal plasma flow were not significantly different from those of inulin and para-aminohippuric acid studies. The reproducibility of the technique was comparable to that of inulin and para-aminohippuric acid studies. Patient acceptance of the technique is excellent and the cost is minimal. Renal morphology and excretory dynamics also are demonstrated. The technique is advocated as a clinical measure of renal function

  12. Calf blood flow at rest evaluated by thermal measurement with tissue temperature and heat flow and 133Xe clearance

    International Nuclear Information System (INIS)

    Tamura, Toshiyo; Togawa, Tatsuo; Fukuoka, Masakazu; Kawakami, Kenji.

    1982-01-01

    The regional blood flow in the calf was determined simultaneously by thermal measurement and by 133 Xe clearance technique. Calf blood flow (Ft) by thermal measurement was accounted for by the equation of the form Ft=(CdT*d+Ho-Mb)/rho sub(b)c su b(D) (Ta-Td), where Cd is thermal capacitance of the calf compartment, T*d is the change of calf tissue temperature, Ta is arterila blood temperature, Td is calf tissue temperature, Ho is the heat dissipation from the compartment to the environment, Mb is estimated metabolism of the calf tissue and rho sub(b)c sub(b) is the product of density and specific heat of blood. The healthy men were chosen for the experiments. Total calf blood flow was 2.53+-1.31ml/(min-100ml calf), and muscle blood flow was 2.63+-1.69ml/(min- 100ml muscle) and skin blood flow 7.19+-3.83ml/(min-100ml skin) measured by 133 Xe clearance. On the basis of the results, an estimate has been made of the proportions of the calf volume which can be ascribed to skin and muscle respectively. Estimated muscle and skin blood flow were correlated with total calf blood flow(r=0.98). (author)

  13. Tear clearance measurement in patients with dry eye syndrome using quantitative lacrimal scintigraphy

    International Nuclear Information System (INIS)

    Gencoglu, E.A.; Dursun, D.; Akova, Y.A.; Cengiz, F.; Yalcin, H.; Koyuncu, A.

    2005-01-01

    The aim of this study was to evaluate the tear clearance in patients with dry eye syndrome using quantitative lacrimal scintigraphy. We investigated 21 patients (42 eyes; 18 women, 3 men; mean age, 63.19±13.33 years) with dry eye syndrome. Additionally, for the sake of comparison, 12 normal subjects of the same age group (24 eyes; 10 women, 2 men; mean age, 68.25±2.63 years) were included. Lacrimal scintigraphy, Schirmer-1 test, break-up time (BUT), and rose bengal ocular surface vital staining were performed in these cases. According to the results of lacrimal scintigraphy, the mean value of T1/2 was 4.16±1.22 minutes and the mean value of radioisotope (RI) was 14.15%±2.30% in normal subjects. However, in patients with dry eye syndrome, these values were 20.59±1.97 minutes and 55.64%±6.90%, respectively. Consistent with the results of ophthalmologic tests, the mean Schirmer-1 value was 12.46±2.10 mm, the mean value of BUT was 14.36±3.40 seconds, and the mean staining value of the rose bengal was 1.98±0.80 in normal subjects, whereas these values were 1.36±0.49 mm, 5.46±1.33 seconds, 6.62±0.86, respectively, in patients with dry eye syndrome. When we compared the results of lacrimal scintigraphy and the results of ophthalmologic tests, an inverse correlation was noted between both the T1/2 and RI values and both the Schirmer-1 and BUT values in all subjects (p<0.001). However, there was a greater positive correlation between the rose bengal ocular surface staining value and both the T1/2 and RI values in all cases (p<0.001). In the current study, it was concluded that although the lacrimal drainage system was normal, tear clearance was significantly delayed in dry eye patients. With this study, we have shown that quantitative lacrimal scintigraphy, which is an objective, practical, and noninvasive method, appears to be useful for the assessment of the tear clearance in patients with dry eye syndrome. (author)

  14. Impact of radical nephrectomy on renal functional outcome in patients with no other co-morbidity as determined by 24-h urinary creatinine clearance

    Directory of Open Access Journals (Sweden)

    H.H. Qureshi

    2015-12-01

    Conclusion: The results from this study show that RN is associated with a decrease in CrCl in one third of the study population. Therefore it is recommended that patients undergoing RN should be strictly monitored for occult renal failure and managed promptly to prevent serious morbidity of frank renal failure.

  15. Glomerular filtration rate is associated with free triiodothyronine in euthyroid subjects : Comparison between various equations to estimate renal function and creatinine clearance

    NARCIS (Netherlands)

    Anderson, Josephine L C; Gruppen, Eke G; van Tienhoven-Wind, Lynnda; Eisenga, Michele F; de Vries, Hanne; Gansevoort, Ron T; Bakker, Stephan J L; Dullaart, Robin P F

    BACKGROUND: Effects of variations in thyroid function within the euthyroid range on renal function are unclear. Cystatin C-based equations to estimate glomerular filtration rate (GFR) are currently advocated for mortality and renal risk prediction. However, the applicability of cystatin C-based

  16. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  17. Close Range Photogrammetry in Space - Measuring the On-Orbit Clearance between Hardware on the International Space Station

    Science.gov (United States)

    Liddle, Donn

    2017-01-01

    real clearance between the ammonia lines and expected position of the thruster bell using existing on-orbit imagery. Imagery of the area of interest, taken several years earlier from the Space Shuttle during a fly-around of the ISS, was found and used to set a stereo pair. Space Vision System Targets and Handrail bolts measured in the ISS analytical coordinate system (ISSACS) prior to launch, were used to obtain an absolute orientation so all photogrammetric measurement's would be in the ISSACS coordinate system. Coordinates for the design location of the edges of the thruster bell, when the cargo vehicle was fully berthed to the ISS, were displayed in 3-D relative to the as-installed ammonia lines. This immediately revealed a positive clearance, which was later quantified to be a minimum of 10" +/0.5". The analysis was completed over a single weekend by a single analyst. Using updated imagery, acquired from the station's robotic arm, a complete as-installed model of the coolant lines was generated from stereo photography and replaced the design model in the master ISS CAD database.

  18. Exaggerated natriuresis and lithium clearance in spontaneously hypertensive rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Kanters, J K; Leyssac, P P

    1988-01-01

    Since hypertension is associated with changes in the handling of various cations (including sodium and lithium) across the cell membrane, the present study investigated the validity of the lithium clearance method in hypertension by comparing two measures of proximal reabsorption. Thus, fractional...... lithium excretion and transit time (TT)-occlusion time (OT; e-TT/T) were determined successively in the same spontaneously hypertensive rat (SHR, Okamoto strain). The rats were examined both before and after an acute saline load. The results show that the lithium clearance method can be used...... for the determination of proximal reabsorption in SHR. Utilizing the lithium clearance method, the changes in renal sodium handling underlying the exaggerated natriuresis were investigated in unanaesthetized catheterized rats. It was found that the exaggerated natriuresis was associated with an increased output from...

  19. Statistical shape modeling based renal volume measurement using tracked ultrasound

    Science.gov (United States)

    Pai Raikar, Vipul; Kwartowitz, David M.

    2017-03-01

    Autosomal dominant polycystic kidney disease (ADPKD) is the fourth most common cause of kidney transplant worldwide accounting for 7-10% of all cases. Although ADPKD usually progresses over many decades, accurate risk prediction is an important task.1 Identifying patients with progressive disease is vital to providing new treatments being developed and enable them to enter clinical trials for new therapy. Among other factors, total kidney volume (TKV) is a major biomarker predicting the progression of ADPKD. Consortium for Radiologic Imaging Studies in Polycystic Kidney Disease (CRISP)2 have shown that TKV is an early, and accurate measure of cystic burden and likely growth rate. It is strongly associated with loss of renal function.3 While ultrasound (US) has proven as an excellent tool for diagnosing the disease; monitoring short-term changes using ultrasound has been shown to not be accurate. This is attributed to high operator variability and reproducibility as compared to tomographic modalities such as CT and MR (Gold standard). Ultrasound has emerged as one of the standout modality for intra-procedural imaging and with methods for spatial localization has afforded us the ability to track 2D ultrasound in physical space which it is being used. In addition to this, the vast amount of recorded tomographic data can be used to generate statistical shape models that allow us to extract clinical value from archived image sets. In this work, we aim at improving the prognostic value of US in managing ADPKD by assessing the accuracy of using statistical shape model augmented US data, to predict TKV, with the end goal of monitoring short-term changes.

  20. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  1. The effects of cimetidine on creatinine excretion, glomerular filtration rate and tubular function in renal transplant recipients

    DEFF Research Database (Denmark)

    Olsen, N V; Ladefoged, S D; Feldt-Rasmussen, B

    1989-01-01

    The renal clearance of endogenous creatinine (CCr), sodium (CNa) and lithium (CLi) was determined before and after a single intravenous bolus of cimetidine in nine renal transplant recipients. The glomerular filtration rate (GFR) was measured with 125I-iothalamate clearance (CTh). The initial CCr...... tubular flow. This suggests that on-going cimetidine treatment must be taken into account when graft function is evaluated by the CCr alone....

  2. Validation of the flow-through chamber (FTC and steady-state (SS methods for clearance rate measurements in bivalves

    Directory of Open Access Journals (Sweden)

    Poul S. Larsen

    2011-09-01

    To obtain precise and reliable laboratory clearance rate (filtration rate measurements with the ‘flow-through chamber method’ (FTC the design must ensure that only inflow water reaches the bivalve's inhalant aperture and that exit flow is fully mixed. As earlier recommended these prerequisites can be checked by a plot of clearance rate (CR versus increasing through-flow (Fl to reach a plateau, which is the true CR, but we also recommend to plot percent particles cleared versus reciprocal through-flow where the plateau becomes the straight line CR/Fl, and we emphasize that the percent of particles cleared is in itself neither a criterion for valid CR measurement, nor an indicator of appropriate ‘chamber geometry’ as hitherto adapted in many studies. For the ‘steady-state method’ (SS, the design must ensure that inflow water becomes fully mixed with the bivalve's excurrent flow to establish a uniform chamber concentration prevailing at its incurrent flow and at the chamber outlet. These prerequisites can be checked by a plot of CR versus increasing Fl, which should give the true CR at all through-flows. Theoretically, the experimental uncertainty of CR for a given accuracy of concentration measurements depends on the percent reduction in particle concentration (100×P from inlet to outlet of the ideal ‘chamber geomety’. For FTC, it decreases with increasing values of P while for SS it first decreases but then increases again, suggesting the use of an intermediate value of P. In practice, the optimal value of P may depend on the given ‘chamber geometry’. The fundamental differences between the FTC and the SS methods and practical guidelines for their use are pointed out, and new data on CR for the blue mussel, Mytilus edulis, illustrate a design and use of the SS method which may be employed in e.g. long-term growth experiments at constant algal concentrations.

  3. Measurement of renal function by calculation of fractional uptake of technetium-99m dimercaptosuccinic acid

    International Nuclear Information System (INIS)

    Beatovic, S.Lj.; Jaksic, E. D.; Hari, R. S.

    2004-01-01

    The purpose of this study was to set up normal values of the fractional uptake (FU) of technetium-99m dimercaptosuccinic acid in adults and in the pediatric population, as well as to evaluate the validity of this parameter at different levels of renal function. A total of 86 subjects was divided into seven groups. In group A there were 23 potential kidney donors and in group B, 18 children in remission after a first urinary tract infection. Another three groups consisted of patients with diabetes i.e. group C, seven patients with normal values of albuminuria, group D, 16 patients with microalbuminuria and group E, five patients with macroalbuminuria. In group F, there were ten patients with a well-functioning transplanted kidney and in group G, seven patients with suspected acute rejection. The procedure began with the quantification of the doses of 99m Tc-DMSA to be injected and the measurement of the empty syringe lying on the gamma camera collimator. Thereafter, four planar views of the kidneys were acquired three hours after the injection. The counts from the posterior and anterior views were subtracted for background and corrected for radioactive decay time and patient thickness. The FU was calculated by the geometric mean of counts per second from the posterior and anterior view. It was expressed as a fraction of the injected dose. The mean values of FU in healthy adults were 0.227 ± 0.077 for one kidney and 0.454 ± 0.146 for both kidneys. The mean values of FU for the left and right kidney were 0.225± 0.071 and 0.229 ± 0.079, respectively. In children, the mean values were 0.220 ± 0.092 for one kidney and 0.432 ± 0.094 for both kidneys. The highest values of FU of 0.322 ± 0.078 (0.644 ± 0.138 for both kidneys) were measured in group C. In group D, FU was 0.185 ± 0.065 (0.361 ± 0.125 for both kidneys) and in group E 0.082 ± 0.040 (0.163 ± 0.080 total). In patients with a transplanted kidney, fractional uptake was 0.162 ± 0.039 in group F and 0

  4. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  5. Glomerular filtration values obtained with 99mTc-DTPA v/s measurements of creatinine Clearance and calculation of the filtered glomerular using the Schwartz formula in a pediatric population

    International Nuclear Information System (INIS)

    Opazo, Claudio; Gutierrez, Elisa; Zamorano, Julio; Troncoso, TM

    2005-01-01

    We compare glomerular filtration rate by DTPA Renogram (DTPA-GFR) with creatinine clearance (CC) and Glomerular filtration rate from Schwartz formula (Schwartz-GFR). The need for using (DTPA-GFR) method raised from the practical difficulties in getting an accurate (CC) in pediatric population. From Sep-2001 to May-2005, 48 patients aged 1month to 18 years, underwent (DTPA-GFR) and (Schwartz-GFR). 18 had also (CC). Comparison were made among these measurements also accounting for age groups. We found a better correlation between (DTPA-GFR) and (CC) Pearson = 0,895. (Schwartz)/(CC) comparison showed a slightly lower correlation Pearson = 0,857. The worst correlation was found comparing (DTPA-GFR)/(Schwartz-GFR) in children < 3 yr Pearson = 0,560. As we found a better correlation between (DTPA-GFR)/(CC) than (DTPA-GFR)/(Schwartz-GFR), DTPA-GFR could be considered reliable method in evaluating renal function in children having difficulties to get a Creatinine Clearance (au)

  6. The investigation of in-vivo measurement of individual renal blood perfusion, effective renal plasma flow and quantitation of renogram and 15 min bladder collection percentage

    International Nuclear Information System (INIS)

    Huang Kangchu

    1991-01-01

    25 normals and 43 renal diseases were examined by the RBF-I multifunctioning renography. The result showed that the determination of ERPF has no difference between blood sampling and noin-blood sampling method, and actually the lattrer can replace the former one. Above method can be also used for the measurement of the individual renal blood perfusion, the quantitation of renogram and the 15 min bladder coolection percentage at the same time. Thereby it provides more complete diagnostic information for the renal vascular diseases, renal pancren chymations and other urologic diseases

  7. Results and validity of renal blood flow measurements using Xenon 133

    International Nuclear Information System (INIS)

    Serres, P.; Danet, B.; Guiraud, R.; Durand, D.; Ader, J.L.

    1975-01-01

    The renal blood flow was measured by external recording of the xenon 133 excretion curve. The study involved 45 patients with permanent high blood pressure and 7 transplant patients. The validity of the method was checked on 10 dogs. From the results it seems that the cortical blood flow, its fraction and the mean flow rate are the most representative of the renal haemodynamics parameters, from which may be established the repercussions of blood pressure on kidney vascularisation. Experiments are in progress on animals to check the compartment idea by comparing injections into the renal artery and into various kidney tissues in situ [fr

  8. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  9. A camera based calculation of 99m Tc-MAG-3 clearance using conjugate views method

    International Nuclear Information System (INIS)

    Hojabr, M.; Rajabi, H.; Eftekhari, M.

    2004-01-01

    Background: measurement of absolute or different renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods is approximations of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in the use of this technique. In this study the conjugate-view method along with some background correction technique have been used for the measurement of renal activity in 99m Tc- MAG 3 renography. Transmission data were used for attenuation correction and the source volume was considered for accurate background subtraction. Materials and methods: the study was performed in 35 adult patients referred to our department for conventional renography and ERPF calculation. Depending on patients weight approximately 10-15 mCi 99 Tc-MAG 3 was injected in the form of a sharp bolus and 60 frames of 1 second followed by 174 frames of 10 seconds were acquired for each patient. Imaging was performed on a dual-head gamma camera(SOLUS; SunSpark10, ADAC Laboratories, Milpitas, CA) anterior and posterior views were acquired simultaneously. A LEHR collimator was used to correct the scatter for the emission and transmission images. Buijs factor was applied on background counts before background correction (Rutland-Patlak equation). gamma camera clearance was calculated using renal uptake in 1-2, 1.5-2.5, 2-3 min. The same procedure was repeated for both renograms obtained from posterior projection and conjugated views. The plasma clearance was also directly calculated by three blood samples obtained at 40, 80, 120 min after injection. Results: 99 Tc-MAG 3 clearance using direct sampling method were used as reference values and compared to the results obtained from the renograms. The maximum correlation was found between conjugate view clearance at 2-3 min (R=0.99, R 2 =0.98, SE=15). Conventional

  10. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  11. The rebirth of interest in renal tubular function.

    Science.gov (United States)

    Lowenstein, Jerome; Grantham, Jared J

    2016-06-01

    The measurement of glomerular filtration rate by the clearance of inulin or creatinine has evolved over the past 50 years into an estimated value based solely on plasma creatinine concentration. We have examined some of the misconceptions and misunderstandings of the classification of renal disease and its course, which have followed this evolution. Furthermore, renal plasma flow and tubular function, which in the past were estimated by the clearance of the exogenous aryl amine, para-aminohippurate, are no longer measured. Over the past decade, studies in experimental animals with reduced nephron mass and in patients with reduced renal function have identified small gut-derived, protein-bound uremic retention solutes ("uremic toxins") that are poorly filtered but are secreted into the lumen by organic anion transporters (OATs) in the proximal renal tubule. These are not effectively removed by conventional hemodialysis or peritoneal dialysis. Residual renal function, urine produced in patients with advanced renal failure or undergoing dialysis treatment, may represent, at least in part, secretion of fluid and uremic toxins, such as indoxyl sulfate, mediated by proximal tubule OATs and might serve as a useful survival function. In light of this new evidence of the physiological role of proximal tubule OATs, we suggest that measurement of renal tubular function and renal plasma flow may be of considerable value in understanding and managing chronic kidney disease. Data obtained in normal subjects indicate that renal plasma flow and renal tubular function might be measured by the clearance of the endogenous aryl amine, hippurate. Copyright © 2016 the American Physiological Society.

  12. Early changes in blood flow of the mouse skin after irradiation as measured by the 133Xe clearance method

    International Nuclear Information System (INIS)

    Tsujii, Hirohiko; Irie, Goro

    1983-01-01

    The early effects of radiation on the local blood flow in the skin of mice were evaluated by measuring the local clearance rate of 133 Xe after its subcutaneous injection; this was done at four to five weeks after irradiation during the animals' normal resting conditions. The fractionation schedules employed were single fractions, two fractions in 15 days and four fractions in 15 days. The dose effect curves with these schedules showed a two-component pattern. There was a uniform reduction in flood flow after 10 to 30 Gy, and a steady increase in flood flow after doses more than 40 Gy. The blood flow after higher-fractionated doses was always lower than less-fractionated doses. It was considered that radiation doses causing higher severity of acute skin reactions might have predominated a degree of acute vasodilatation over fibrotic changes, thus resulting in increased blood flow. A steady increase in early blood flow was observed with increasing severity of acute skin reactions, but the early blood flow was not a good indicator for predicting late skin reactions, except for a severe leg deformity which was accompanied with a significant increase in early blood flow. (author)

  13. Endometrial blood flow measured by xenon 133 clearance in women with normal menstrual cycles and dysfunctional uterine bleeding

    International Nuclear Information System (INIS)

    Fraser, I.S.; McCarron, G.; Hutton, B.; Macey, D.

    1987-01-01

    Endometrial blood flow was measured through the menstrual cycle in nonpregnant women (28 studies of 17 women with normal menstrual cycles and 32 studies of 20 women with dysfunctional uterine bleeding) with use of a clearance technique in which 100 to 400 microCi of the gamma-emitting isotope, xenon 133 in saline solution was instilled into the uterine cavity. The mean (+/- SEM) endometrial blood flow in normal cycles was 27.7 +/- 2.6 ml/100 gm/min, with a significant elevation in the middle to late follicular phase, followed by a substantial fall and a secondary slow luteal phase rise that was maintained until the onset of menstruation. There was a significant correlation between plasma estradiol levels and endometrial blood flow in the follicular but not the luteal phase. Blood flow patterns in women with ovulatory dysfunctional bleeding were similar to normal, except for a significantly lower middle follicular rate. Women with anovulatory dysfunctional bleeding exhibited exceedingly variable flow rates

  14. Endometrial blood flow measured by xenon 133 clearance in women with normal menstrual cycles and dysfunctional uterine bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, I.S.; McCarron, G.; Hutton, B.; Macey, D.

    1987-01-01

    Endometrial blood flow was measured through the menstrual cycle in nonpregnant women (28 studies of 17 women with normal menstrual cycles and 32 studies of 20 women with dysfunctional uterine bleeding) with use of a clearance technique in which 100 to 400 microCi of the gamma-emitting isotope, xenon 133 in saline solution was instilled into the uterine cavity. The mean (+/- SEM) endometrial blood flow in normal cycles was 27.7 +/- 2.6 ml/100 gm/min, with a significant elevation in the middle to late follicular phase, followed by a substantial fall and a secondary slow luteal phase rise that was maintained until the onset of menstruation. There was a significant correlation between plasma estradiol levels and endometrial blood flow in the follicular but not the luteal phase. Blood flow patterns in women with ovulatory dysfunctional bleeding were similar to normal, except for a significantly lower middle follicular rate. Women with anovulatory dysfunctional bleeding exhibited exceedingly variable flow rates.

  15. Effects of external pressure loading on human skin blood flow measured by 133Xe clearance

    International Nuclear Information System (INIS)

    Holloway, G.A. Jr.; Daly, C.H.; Kennedy, D.; Chimoskey, J.

    1976-01-01

    Forearm skin blood flow was measured during external pressure loading in normal human subjects using 133 Xe washout from intracutaneous injection sites. Pressures ranging between 5 and 150 mmHg were applied through a 3-cm-diameter disc placed over the site of flow determination. The pressure was maintained constant by a servo-controlled loading mechanism. Flow decreased with pressures from 5 to 10 and 30 to 150 mmHg, but remained constant with pressures from 10 to 30 mmHg. Reactive hyperemia occurred following removal of pressures of 90 mmHg or greater, but did not occur following removal of lower pressures. The pressure-flow curve for parasacral skin of paraplegic subjects closely paralleled the pressure-flow curve of normal skin at pressures tested: 5 to 15 mmHg. These data are interpreted to demonstrate autoregulation of skin blood flow. Autoregulation in parasacral skin of paraplegic subjects suggests a peripheral mechanism. The occurrence of hyperemia at pressures which exceed the ability of skin to autoregulate suggests that both autoregulation and post occlusion hyperemia may have the same mechanism

  16. Dynamic {sup 18}F-fluoride small animal PET to noninvasively assess renal function in rats

    Energy Technology Data Exchange (ETDEWEB)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael [Klinik und Poliklinik fuer Nuklearmedizin, Muenster (Germany); Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert [Universitaetsklinikum Muenster, Medizinische Klinik und Poliklinik D, Experimentelle Nephrologie, Muenster (Germany)

    2008-12-15

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a {sup 18}F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq {sup 18}F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal {sup 18}F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide {sup 99m}Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ({sup 18}F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. {sup 18}F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  17. Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in rats

    International Nuclear Information System (INIS)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael; Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert

    2008-01-01

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a 18 F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq 18 F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal 18 F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide 99m Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ( 18 F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. 18 F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  18. Utility of radioisotopic filtration markers in chronic renal insufficiency: Simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc-DTPA, and inulin. The Modification of Diet in Renal Disease Study

    International Nuclear Information System (INIS)

    Perrone, R.D.; Steinman, T.I.; Beck, G.J.; Skibinski, C.I.; Royal, H.D.; Lawlor, M.; Hunsicker, L.G.

    1990-01-01

    Assessment of glomerular filtration rate (GFR) with inulin is cumbersome and time-consuming. Radioisotopic filtration markers have been studied as filtration markers because they can be used without continuous intravenous (IV) infusion and because analysis is relatively simple. Although the clearances of 99mTc-DTPA, 169Yb-DTPA, and 125I-iothalamate have each been compared with inulin, rarely has the comparability of radioisotopic filtration markers been directly evaluated in the same subject. To this purpose, we determined the renal clearance of inulin administered by continuous infusion and the above radioisotopic filtration markers administered as bolus injections, simultaneously in four subjects with normal renal function and 16 subjects with renal insufficiency. Subjects were studied twice in order to assess within-study and between-study variability. Unlabeled iothalamate was infused during the second half of each study to assess its effect on clearances. We found that renal clearance of 125I-iothalamate and 169Yb-DTPA significantly exceeded clearance of inulin in patients with renal insufficiency, but only by several mL.min-1.1.73m-2. Overestimation of inulin clearance by radioisotopic filtration markers was found in all normal subjects. No differences between markers were found in the coefficient of variation of clearances either between periods on a given study day (within-day variability) or between the two study days (between-day variability). The true test variability between days did not correlate with within-test variability. We conclude that the renal clearance of 99mTc-DTPA, 169Yb-DTPA, or 125I-iothalamate administered as a single IV or subcutaneous injection can be used to accurately measure GFR in subjects with renal insufficiency; use of the single injection technique may overestimate GFR in normal subjects

  19. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by /sup 133/Xe clearance technique

    Energy Technology Data Exchange (ETDEWEB)

    Basa, S; Ercan, M T; Aras, T; Araz, K

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of /sup 133/Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), /sup 133/Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2+-12.9 and 58.3+-3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4+-3.2 and 21.7+-15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2+-16.9 ml/100 g/min) and above (63.9+-9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing.

  20. Serum cystatin C concentration measured routinely is a prognostic marker for renal disease in dogs.

    Science.gov (United States)

    Iwasa, Naoki; Takashima, Satoshi; Iwasa, Tatsuo; Iwasa, Kazuko; Suzuki, Tomomi; Kobatake, Yui; Kitagawa, Hitoshi; Nishii, Naohito

    2018-06-14

    This study examined the predictive value of serum cystatin C (Cys-C) concentration, measured during routine periodic health examinations, in the renal prognosis of dogs. A cohort of 140 dogs weighing C concentrations were measured during periodic health examinations from December 2013 to March 2016 were prospectively studied, with renal disease-related death the predicted end point. Of the 140 dogs, nine died from renal diseases during the follow-up period (539 ± 249 days). Serum Cys-C concentrations were higher in the dogs that subsequently died of renal disease than in the censored group (0.8 ± 0.25 vs. 0.3 ± 0.1 mg/dl, respectively; P C concentrations (>0.55 mg/dl) had a shorter (P C concentrations (≤0.55 mg/dl). In conclusion, high serum Cys-C concentrations in periodic health examinations in dogs <15 kg predicted poorer prognosis for renal function. Copyright © 2018. Published by Elsevier Ltd.

  1. The description of a method for accurately estimating creatinine clearance in acute kidney injury.

    Science.gov (United States)

    Mellas, John

    2016-05-01

    Acute kidney injury (AKI) is a common and serious condition encountered in hospitalized patients. The severity of kidney injury is defined by the RIFLE, AKIN, and KDIGO criteria which attempt to establish the degree of renal impairment. The KDIGO guidelines state that the creatinine clearance should be measured whenever possible in AKI and that the serum creatinine concentration and creatinine clearance remain the best clinical indicators of renal function. Neither the RIFLE, AKIN, nor KDIGO criteria estimate actual creatinine clearance. Furthermore there are no accepted methods for accurately estimating creatinine clearance (K) in AKI. The present study describes a unique method for estimating K in AKI using urine creatinine excretion over an established time interval (E), an estimate of creatinine production over the same time interval (P), and the estimated static glomerular filtration rate (sGFR), at time zero, utilizing the CKD-EPI formula. Using these variables estimated creatinine clearance (Ke)=E/P * sGFR. The method was tested for validity using simulated patients where actual creatinine clearance (Ka) was compared to Ke in several patients, both male and female, and of various ages, body weights, and degrees of renal impairment. These measurements were made at several serum creatinine concentrations in an attempt to determine the accuracy of this method in the non-steady state. In addition E/P and Ke was calculated in hospitalized patients, with AKI, and seen in nephrology consultation by the author. In these patients the accuracy of the method was determined by looking at the following metrics; E/P>1, E/P1 and 0.907 (0.841, 0.973) for 0.95 ml/min accurately predicted the ability to terminate renal replacement therapy in AKI. Include the need to measure urine volume accurately. Furthermore the precision of the method requires accurate estimates of sGFR, while a reasonable measure of P is crucial to estimating Ke. The present study provides the

  2. Assessment of vandetanib as an inhibitor of various human renal transporters: inhibition of multidrug and toxin extrusion as a possible mechanism leading to decreased cisplatin and creatinine clearance.

    Science.gov (United States)

    Shen, Hong; Yang, Zheng; Zhao, Weiping; Zhang, Yueping; Rodrigues, A David

    2013-12-01

    Vandetanib was evaluated as an inhibitor of human organic anion transporter 1 (OAT1), OAT3, organic cation transporter 2 (OCT2), and multidrug and toxin extrusion (MATE1 and MATE2K) transfected (individually) into human embryonic kidney 293 cells (HEK293). Although no inhibition of OAT1 and OAT3 was observed, inhibition of OCT2-mediated uptake of 1-methyl-4-phenylpyridinium (MPP(+)) and metformin was evident (IC(50) of 73.4 ± 14.8 and 8.8 ± 1.9 µM, respectively). However, vandetanib was an even more potent inhibitor of MATE1- and MATE2K-mediated uptake of MPP(+) (IC(50) of 1.23 ± 0.05 and 1.26 ± 0.06 µM, respectively) and metformin (IC(50) of 0.16 ± 0.05 and 0.30 ± 0.09 µM, respectively). Subsequent cytotoxicity studies demonstrated that transport inhibition by vandetanib (2.5 µM) significantly decreased the sensitivity [right shift in concentration of cisplatin giving rise to 50% cell death; IC(50(CN))] of MATE1-HEK and MATE2K-HEK cells to cisplatin [IC(50(CN)) of 1.12 ± 0.13 versus 2.39 ± 0.44 µM; 0.85 ± 0.09 versus 1.99 ± 0.16 µM; P cisplatin nephrotoxicity (reduced cisplatin clearance), in some subjects receiving vandetanib therapy.

  3. Comparative study of conventional PAH and inulin clearance and slope clearance of 131I-o-hippuric acid and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Berghaeuser, H.

    1981-01-01

    ''Classic'' PAH and inulin clearance were determined in 81 patients with renal anomalies or renal diseases of different genesis and severity. In addition, radioisotope nephrography was carried out after administration of I-131-o-hippuric acid, followed by administration of Cr-51-EDTA. The activity decrease was recorded by a sensor located over the patient's right shoulder; the activities of a serum sample and of the urine excreted after 21 or 31 min were measured, and the findings were compared with those of the classic method. The clearance data calculated on the basis of the soulder measurements were hardly compatible with those of the conventional method in the case of 131 I-o-hippuric acid (r=0.54) and totally incompatible in the case of 51 Cr-EDTA. This means that the method described by Oberhausen is the only accurate method available for a quantitative assessment of the renal function on the basis of measurements of the activity decrease in the body. The activity of urine excreted after 31 min ( 131 I-hippuric acid:r=0.992, 51 Cr-EDTA:r=0.79) is a sufficiently accurate parameter although it is inaccurate at PAH clearance, values > 130 ml/min and inulin clearance values > 30 ml/min. Of the many parameters of radioisotope nephrogram curves, in the case of 131 I-o-hippuric acid only the parameters related to the ascent between 48 and 120 sec or to the secant ascent yield sufficient quantitative information for certain functional regions (r=0.9 resp. r=0.93). In the case of 51 Cr-EDTA, semiquantitative information on the renal function can be obtained by constructing secants on the nephrogram curves (r=0.7 resp. r=0.72). Here as in the case of 131 I-hippuric acid, the contribution of each kidney can be determined individually from the functional analysis of both kidneys. (orig.) [de

  4. Ethylene and ammonia traces measurements from the patients' breath with renal failure via LPAS method

    Science.gov (United States)

    Popa, C.; Dutu, D. C. A.; Cernat, R.; Matei, C.; Bratu, A. M.; Banita, S.; Dumitras, D. C.

    2011-11-01

    The application of laser photoacoustic spectroscopy (LPAS) for fast and precise measurements of breath biomarkers has opened up new promises for monitoring and diagnostics in recent years, especially because breath test is a non-invasive method, safe, rapid and acceptable to patients. Our study involved assessment of breath ethylene and breath ammonia levels in patients with renal failure receiving haemodialysis (HD) treatment. Breath samples from healthy subjects and from patients with renal failure were collected using chemically inert aluminized bags and were subsequently analyzed using the LPAS technique. We have found out that the composition of exhaled breath in patients with renal failure contains not only ethylene, but also ammonia and gives valuable information for determining efficacy and endpoint of HD. Analysis of ethylene and ammonia traces from the human breath may provide insight into severity of oxidative stress and metabolic disturbances and may ensure optimal therapy and prevention of pathology at patients on continuous HD.

  5. Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.

    Science.gov (United States)

    Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak

    2012-06-01

    Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the

  6. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  7. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  8. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  9. Accurate determination of renal function in patients with intestinal urinary diversions

    International Nuclear Information System (INIS)

    McDougal, W.S.; Koch, M.O.

    1986-01-01

    The regular determination of renal function is a critical part of the management of patients who have had the urinary tract reconstructed with intestinal segments. These intestinal segments reabsorb urinary solutes and, thereby, complicate the determination of renal function by conventional methods. Urinary clearances of urea, creatinine and inulin were performed in patients with intestinal segments in the urinary tract and controls under varying diuretic conditions. Patients with intestinal diversions also underwent radioisotopic determination of renal function. The urinary clearances of urea, creatinine and inulin are highly dependent on the rate of urine flow in patients with intestinal segments in the urinary tract. Diuresis maximizes the urinary clearances of these solutes by minimizing intestinal reabsorption. Creatinine clearance prediction from the serum creatinine underestimates true glomerular filtration rate. Radioisotopic determination of renal function correlates poorly with true glomerular filtration rate. Only creatinine clearance measured under diuretic conditions correlates well with true renal function. Urine concentrating ability cannot be assessed accurately in patients with intestinal segments in the urinary tract, since osmolality rapidly equilibrates across the segments

  10. Effect of renal venous pressure elevation on tubular sodium and water reabsorption in the dog kidney

    DEFF Research Database (Denmark)

    Abildgaard, U; Amtorp, O; Holstein-Rathlou, N H

    1988-01-01

    of [51Cr]EDTA was used as a measure of the rate of glomerular filtration (GFR). GFR, urinary excretion rates of sodium and water, and lithium clearance were used for assessing the absolute and fractional reabsorption rates of sodium and water in the proximal as well as in more distal segments......This study was performed in order to quantify the effects of renal venous pressure (RVP) elevation on absolute and fractional reabsorption rates of sodium and water in proximal and distal segments of the nephron in dog kidneys. Renal blood flow (RBF) was measured electromagnetically. Clearance...

  11. Renal functional recovery of the hydronephrotic kidney predicted before relief of the obstruction

    International Nuclear Information System (INIS)

    McDougal, W.S.; Flanigan, R.C.

    1981-01-01

    Employing technetium labeled dimercaptosuccinic acid, we predicted the inulin and p-aminohippuric acid (PAH) clearances after recovery of an obstructed kidney before relief of the obstruction. Sixteen rabbits had one renal unit obstructed for varying period of time. The animals were scanned immediately before relief of the obstruction. After 4 to 6 months recovery, inulin and PAH clearances were measured in all animals. The scans were mathematically analyzed, and accurately predicted the inulin and PAH clearances obtained after complete recovery (P less than 0.001 and P less than 0.001, respectively). Six rabbits were scanned at the time of the clearance measurements. By a different mathematical analysis, inulin and PAH clearance measured concurrently correlated with the scan

  12. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  13. Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

    International Nuclear Information System (INIS)

    Pai Panandiker, Atmaram S.; Sharma, Shelly; Naik, Mihir H.; Wu, Shengjie; Hua, Chiaho; Beltran, Chris; Krasin, Matthew J.; Merchant, Thomas E.

    2012-01-01

    Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2–18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5–9 mm in the ML direction, 4–11 mm in the AP direction, and 12–25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5–16 mm in the ML direction, 6–17 mm in the AP direction, and 21–52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

  14. Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pai Panandiker, Atmaram S., E-mail: atmaram.pai-panandiker@stjude.org [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, TN (United States); Sharma, Shelly; Naik, Mihir H. [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, TN (United States); Wu, Shengjie [Department of Biostatistics, St. Jude Children' s Research Hospital, Memphis, TN (United States); Hua, Chiaho; Beltran, Chris; Krasin, Matthew J.; Merchant, Thomas E. [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2012-04-01

    Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

  15. Using BOLD imaging to measure renal oxygenation dynamics in rats injected with diuretics

    International Nuclear Information System (INIS)

    Kusakabe, Yoshinori; Matsushita, Taro; Honda, Saori; Okada, Sakie; Murase, Kenya

    2010-01-01

    We used blood oxygenation level-dependent magnetic resonance imaging (BOLD MRI) to measure renal oxygenation dynamics in rats injected with diuretics and evaluated diuretic effect on renal oxygenation. We performed BOLD MRI studies in 32 rats using a 1.5-tesla MR imaging system for animal experiments. We intravenously injected rats with saline (n=7), furosemide (n=7), acetazolamide (n=6), or mannitol (n=6). For controls, 6 rats were not injected with drugs. We estimated the apparent transverse relaxation rate (R 2 *) from the apparent transverse relaxation time (T 2 *)-weighted images and measured the time course of R 2 * at 4-min intervals over approximately 30 min. Compared with preadministration values, the R 2 * value did not change significantly in either the cortex or medulla in the control and mannitol groups but decreased significantly in the saline group; the R 2 * value significantly decreased in the medulla but did not change significantly in the cortex in the furosemide group; and the R 2 * value significantly increased in the medulla and significantly decreased in the cortex in the acetazolamide group. Our study results suggest that BOLD MRI is useful for evaluating the dynamics of renal oxygenation in response to various diuretics in the renal cortex and in the medulla. (author)

  16. Monitoring renal function in children with Fabry disease: comparisons of measured and creatinine-based estimated glomerular filtration rate

    NARCIS (Netherlands)

    Tøndel, Camilla; Ramaswami, Uma; Aakre, Kristin Moberg; Wijburg, Frits; Bouwman, Machtelt; Svarstad, Einar

    2010-01-01

    Studies on renal function in children with Fabry disease have mainly been done using estimated creatinine-based glomerular filtration rate (GFR). The aim of this study was to compare estimated creatinine-based GFR (eGFR) with measured GFR (mGFR) in children with Fabry disease and normal renal

  17. Studies on the evaluation of renal function in urological renal disorders with 99mTc-DMSA renal uptake, 1

    International Nuclear Information System (INIS)

    Takeda, Masayuki

    1987-01-01

    The change of normal value of 99m Tc-dimercaptosuccinic acid (DMSA) renal uptake with age was investigated, and the correlation between total renal uptake of 99m Tc-DMSA and 24-hour endogenous creatinine clearance was studied in each age group separately. (1) 99m Tc-DMSA renal uptake was measured in 107 normal controls without renal or urinary tract diseases between 0 and 67 years old and normal values were analyzed in each age group. The normal value was highest in the age group of 0 ∼ 9 years old and was gradually decreased with age. Over 20 years old, the normal value hardly changed. (2) The lower limit of normal values of 99m Tc-DMSA renal uptake in each kidney was 19.62, 13.89, 13.18, 11.58, 12.00, 10.24 % in the age groups of 0 ∼ 9, 10 ∼ 19, 20 ∼ 29, 30 ∼ 39, 40 ∼ 49, 50 ∼ 59 years old, respectively. (3) Correlations between total renal uptake and 24-hour endogenous creatinine clearance were investigated in each age group in 248 patients between 0 and 79 years old. Positive linear correlations were found in the age groups of 0 ∼ 9, 10 ∼ 19, 20 ∼ 29, 30 ∼ 39, 40 ∼ 49, 50 ∼ 59, 60 ∼ 69, 70 ∼ 79 years old, and especially above 50 years old closer correlations were found. It is concluded that although 99m Tc-DMSA renal uptake is a useful method for renal function test through life, the change with age must be considered in the evaluation of its value. (author)

  18. Tip-leakage cavitation in the clearance of a 2D hydrofoil with fillets: high-speed visualization and PIV/PTV measurements

    Science.gov (United States)

    Zapryagaev, Ivan I.; Timoshevskiy, Mikhail V.; Pervunin, Konstantin S.

    2017-09-01

    Tip-clearance cavitation is one of the most aggressive forms of cavitation as it can cause surface erosion of hydraulic machinery elements and, as a result, their fatigue damage and disturb designed operating conditions. At present, the literature lacks for detailed experimental data on the inception and development of this type of cavitation at various flow conditions. In the paper, a tip-leakage cavitation occurring in the clearance between an end face of a 2D hydrofoil (a scaled-down model of guide vanes (GV) of a Francis turbine) and a transparent wall of the test section was studied. The experiments were carried out for different cavitating regimes on the cavitation number and two attack angles of 3° and 9°, with the gap size (tip clearance width) varied in the range from 0.4 to 0.8 mm. In order to determine the cavitation inception conditions and investigate the dynamics of the tip-leakage cavitation, a high-speed visualization was applied. A modified PIV/PTV technique with a diverging laser beam instead of a laser light sheet was used to measure the mean velocity distributions within the gap. It was shown that the cavitation pattern on the suction side of the GV model impacts the dynamics of the leakage flow in the gap but does not affect the sheet cavity formed close to the foil leading edge in the clearance as well as its size and dynamics. When the gap size is increased, the tip-leakage cavitation initiates at higher cavitation numbers or, in other words, conditions for the cavitation occurrence become more favorable.

  19. How to measure renal artery stenosis - a retrospective comparison of morphological measurement approaches in relation to hemodynamic significance

    International Nuclear Information System (INIS)

    Andersson, Malin; Jägervall, Karl; Eriksson, Per; Persson, Anders; Granerus, Göran; Wang, Chunliang; Smedby, Örjan

    2015-01-01

    Although it is well known that renal artery stenosis may cause renovascular hypertension, it is unclear how the degree of stenosis should best be measured in morphological images. The aim of this study was to determine which morphological measures from Computed Tomography Angiography (CTA) and Magnetic Resonance Angiography (MRA) are best in predicting whether a renal artery stenosis is hemodynamically significant or not. Forty-seven patients with hypertension and a clinical suspicion of renovascular hypertension were examined with CTA, MRA, captopril-enhanced renography (CER) and captopril test (Ctest). CTA and MRA images of the renal arteries were analyzed by two readers using interactive vessel segmentation software. The measures included minimum diameter, minimum area, diameter reduction and area reduction. In addition, two radiologists visually judged the diameter reduction without automated segmentation. The results were then compared using limits of agreement and intra-class correlation, and correlated with the results from CER combined with Ctest (which were used as standard of reference) using receiver operating characteristics (ROC) analysis. A total of 68 kidneys had all three investigations (CTA, MRA and CER + Ctest), where 11 kidneys (16.2 %) got a positive result on the CER + Ctest. The greatest area under ROC curve (AUROC) was found for the area reduction on MRA, with a value of 0.91 (95 % confidence interval 0.82–0.99), excluding accessory renal arteries. As comparison, the AUROC for the radiologists’ visual assessments on CTA and MRA were 0.90 (0.82–0.98) and 0.91 (0.83–0.99) respectively. None of the differences were statistically significant. No significant differences were found between the morphological measures in their ability to predict hemodynamically significant stenosis, but a tendency of MRA having higher AUROC than CTA. There was no significant difference between measurements made by the radiologists and measurements made with

  20. Evaluation of {sup 123}I-orthoiodohippurate single kidney clearance rate by renal sequential scintigraphy in a large cohort of likely normal subjects aged between 0 and 18 years

    Energy Technology Data Exchange (ETDEWEB)

    Imperiale, Alessio; Olianti, Catia; Comis, Giannetto; Cava, Giuseppe la [University of Florence, Nuclear Medicine Unit, Department of Clinical Pathophysiology, Florence (Italy)

    2006-12-15

    Age-related values of{sup 123}I-orthoiodohippurate (OIH) single kidney clearance rate (Cl) were estimated in a large cohort of likely normal children aged between 0 and 18 years. Among 4,111 children examined in the past 10 years, 917 were selected with the following inclusion criteria: (a) mild ultrasonographic hydronephrosis with right differential renal function (DRF) <53% and >47% (498 pts), (b) known or suspected urinary tract infection with normal ultrasound, serum creatinine and DMSA and DRF <53% and >47% (419 pts).{sup 123}I-OIH-Cl was assessed using a validated gamma camera method. Children were divided into 21 age classes: from 0 to 2 years, eight 3-month classes; from 2 to 14 years, twelve 1-year classes; from 14 to 18 years, one 4-year class. Cl, plotted against age, was fitted using an increasing function (y = a - be - cx). Mean{sup 123}I-OIH-Cl of 1,834 kidneys was 306{+-}22 ml/min/1.73 m{sup 2} BSA. Mean{sup 123}I-OIH-Cl of the right and left kidneys was 307{+-}23 and 305{+-}22 ml/min/1.73 m{sup 2} BSA, respectively (p<0.002). The best-fitting{sup 123}I-OIH-Cl growing function was: Cl=311-230e-0.69 x Age (months).{sup 123}I-OIH-Cl improved progressively starting from birth, reaching 96% and 98% of the mature value at 1 and 1.5 years, respectively.{sup 123}I-OIH-Cl at birth (age=0) was 81 ml/min/1.73 m{sup 2} BSA. After 18.6 days of life, the renal function had doubled its starting value, and it reached a plateau of 311 ml/min/1.73 m{sup 2} BSA at 2 years. This work represents a systematic evaluation of ERPF by a gamma camera method in a large cohort of selected likely normal paediatric subjects. (orig.)

  1. Human serum albumin homeostasis: a new look at the roles of synthesis, catabolism, renal and gastrointestinal excretion, and the clinical value of serum albumin measurements

    Directory of Open Access Journals (Sweden)

    Levitt DG

    2016-07-01

    Full Text Available David G Levitt,1,* Michael D Levitt2,* 1Department of Integrative Biology and Physiology, University of Minnesota, 2Research Service, Veterans Affairs Medical Center, Minneapolis, MN, USA *These authors contributed equally to this work Abstract: Serum albumin concentration (CP is a remarkably strong prognostic indicator of morbidity and mortality in both sick and seemingly healthy subjects. Surprisingly, the specifics of the pathophysiology underlying the relationship between CP and ill-health are poorly understood. This review provides a summary that is not previously available in the literature, concerning how synthesis, catabolism, and renal and gastrointestinal clearance of albumin interact to bring about albumin homeostasis, with a focus on the clinical factors that influence this homeostasis. In normal humans, the albumin turnover time of about 25 days reflects a liver albumin synthesis rate of about 10.5 g/day balanced by renal (≈6%, gastrointestinal (≈10%, and catabolic (≈84% clearances. The acute development of hypoalbuminemia with sepsis or trauma results from increased albumin capillary permeability leading to redistribution of albumin from the vascular to interstitial space. The best understood mechanism of chronic hypoalbuminemia is the decreased albumin synthesis observed in liver disease. Decreased albumin production also accounts for hypoalbuminemia observed with a low-protein and normal caloric diet. However, a calorie- and protein-deficient diet does not reduce albumin synthesis and is not associated with hypoalbuminemia, and CP is not a useful marker of malnutrition. In most disease states other than liver disease, albumin synthesis is normal or increased, and hypoalbuminemia reflects an enhanced rate of albumin turnover resulting either from an increased rate of catabolism (a poorly understood phenomenon or enhanced loss of albumin into the urine (nephrosis or intestine (protein-losing enteropathy. The latter may occur

  2. Radiopharmaceuticals for renal studies

    International Nuclear Information System (INIS)

    Verdera, Silvia

    1994-01-01

    Between the diagnostic techniques using radiopharmaceuticals in nuclear medicine it find renal studies.A brief description about renal glomerular filtration(GFR) and reliability renal plasma flux (ERPF),renal blood flux measurement agents (RBF),renal scintillation agents and radiation dose estimates by organ physiology was given in this study.tabs

  3. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  4. Non-postural serial changes in renal function during the third trimester of normal human pregnancy.

    Science.gov (United States)

    Ezimokhai, M; Davison, J M; Philips, P R; Dunlop, W

    1981-05-01

    Seventeen healthy women were investigated near the beginning and again near the end of the third trimester of their normal pregnancies. Infusion studies were performed in the left lateral position. There was a highly significant decrease in effective renal plasma flow but not in glomerular filtration rate, measured as inulin clearance. Plasma creatinine concentration increased significantly, but the renal handling of creatinine was unchanged; simultaneous 24-hour creatinine clearance showed a tendency to decrease. Serum urate concentration also increased significantly, apparently due to an increase in net tubular reabsorption of urate.

  5. Role of serum creatinine for screening renal diseases

    International Nuclear Information System (INIS)

    Younas, M.; Khan, F.A.; Sattar, A.; Kazmi, A.

    2011-01-01

    Chronic kidney disease (CKD) is a public Heath problem with increasing prevalence in Pakistan. Early identification of mild renal disease can delay its progression. Glomerular filtration rate (GFR) is the best overall index of renal function, but it is difficult to measure, so mostly clinicians rely on. serum creatinine (SCr) concentration which its own limitations. On the other hand 24 hours (h) urinary creatinine clearance (CICl) is a more sensitive marker of renal dysfunction. Presently SCr is being used in our clinical practice to screen the renal diseases which can miss mild renal dysfunctions, so this study was designed to calculate frequency of individuals having reduced GFR as determined by CrCI having normal SCr levels. (author)

  6. Measurement of regional pulmonary function with carbon-11-labeled CO/sub 2/ and CO. Studies of radioactive gas clearance curve

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, K; Rikitake, T; Hasegawa, S [Tsukuba Univ., Sakura, Ibaraki Japan; Matsumoto, T; Tateno, Y

    1979-06-01

    Carbon dioxide and carbon monoxide labelled with carbon-11 have been produced in the remotecontrolled system for a large scale production of short lived radioactive substance with cyclotron in National Institute of Radiological Sciences. The single breath measurement with /sup 11/CO/sub 2/ and /sup 11/CO, using inhalation system and a coincidence positron camera combined with an on-line computer system (TOSBAC 3400 Model 31) has been employed to evaluate regional pulmonary blood flow and diffusing capacity in three normal volunteers and seven patients with chronic obstructive pulmonary disease (COPD), old lung tuberculosis and benign tumor. Regional clearance rate constant (lambda) and distribution index (lambda i/lambda t) were calculated from monoexponential removal curves measured by external counting over the chest in supine position. This process was performed in a short period of breath-holding (10 - 20 sec.) after a single breath of these radioactive gases mixed with room air. These parameters were calculated for each lung fields divided into four zones (bilateral upper and lower lung region). In our method, the activity of the inspired mixture were 5 - 35 mCi/L and each value in lung fields, divided into four zones, can be measured with time interval for one second. While the clearance rate of /sup 11/CO/sub 2/ seemed to be mainly limited by pulmonary blood flow, it was considered that the rate of /sup 11/CO were limited by not only the diffusing capacity but also the perfusion in each lung fields. In normal subjects, the distribution of regional clearance rate was showed approximately even for /sup 11/CO/sub 2/ and /sup 11/CO. It was caused of the measurement in supine position. In contrast, the distribution of these parameter was showed uneven in patients with lung disease, particularly with COPD.

  7. Evaluation of plasma clearance by synthesis of continuous infusion: principles and use

    International Nuclear Information System (INIS)

    Chonacky, N.J.; Thomas, F.D.

    1986-01-01

    There is a technique of engineering analysis which can be described as impulse synthesis which uses the observational data of a system's response to a single sharp blow in order to predict its response to a steady force. This same technique has been applied to the calculation of in situ drug levels and for calculating plasma clearance values. The purpose of this paper is to elucidate the principles of this calculation technique and to critically assess its application to plasma clearance studies. We begin by tracing the history of the measurement of renal clearance of plasma. We then proceed to exposit the relevant principles of the synthesis technique. Finally, we report the results of our application of this technique to the analysis of simulated data in a manner intended to be of use to clinicians who might wish to consider employing the technique

  8. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  9. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  10. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods

    International Nuclear Information System (INIS)

    Balachandran, S.; Toguri, A.G.; Petrusick, T.W.; Abbott, L.C.

    1981-01-01

    Good correlation of glomerular filtration rate (GFR) measured isotopically from plasma disappearance of Tc-99m-DTPA (Sn) was shown with inulin clearance, creatinine clearance, and graded radionuclide imaging. The isotopic GFR is a simple, urineless technique not requiring continuous infusion that enables one to perform simultaneous renal imaging with one radiotracer

  11. The effects of cimetidine on creatinine excretion, glomerular filtration rate and tubular function in renal transplant recipients

    DEFF Research Database (Denmark)

    Olsen, N V; Ladefoged, S D; Feldt-Rasmussen, B

    1989-01-01

    The renal clearance of endogenous creatinine (CCr), sodium (CNa) and lithium (CLi) was determined before and after a single intravenous bolus of cimetidine in nine renal transplant recipients. The glomerular filtration rate (GFR) was measured with 125I-iothalamate clearance (CTh). The initial CCr...... of 65 ml/min (median) was reduced to a nadir of 46 ml/min (p less than 0.01) during the first 2 h after infusion of cimetidine. GFR remained unchanged, and thus the fractional clearance of creatinine (CCr/CTh) was reduced from 1.43 (median) to 1.03 (p less than 0.01). CNa and the fractional excretion...... of sodium decreased throughout the study (p less than 0.05); CLi was unchanged. In conclusion cimetidine, when measured during 1-h clearance periods, interferes with tubular creatinine secretion in the denervated kidney of transplant recipients without affecting the glomerular filtration rate or proximal...

  12. Detailing the relation between renal T2* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements.

    Science.gov (United States)

    Pohlmann, Andreas; Arakelyan, Karen; Hentschel, Jan; Cantow, Kathleen; Flemming, Bert; Ladwig, Mechthild; Waiczies, Sonia; Seeliger, Erdmann; Niendorf, Thoralf

    2014-08-01

    This study was designed to detail the relation between renal T2* and renal tissue pO2 using an integrated approach that combines parametric magnetic resonance imaging (MRI) and quantitative physiological measurements (MR-PHYSIOL). Experiments were performed in 21 male Wistar rats. In vivo modulation of renal hemodynamics and oxygenation was achieved by brief periods of aortic occlusion, hypoxia, and hyperoxia. Renal perfusion pressure (RPP), renal blood flow (RBF), local cortical and medullary tissue pO2, and blood flux were simultaneously recorded together with T2*, T2 mapping, and magnetic resonance-based kidney size measurements (MR-PHYSIOL). Magnetic resonance imaging was carried out on a 9.4-T small-animal magnetic resonance system. Relative changes in the invasive quantitative parameters were correlated with relative changes in the parameters derived from MRI using Spearman analysis and Pearson analysis. Changes in T2* qualitatively reflected tissue pO2 changes induced by the interventions. T2* versus pO2 Spearman rank correlations were significant for all interventions, yet quantitative translation of T2*/pO2 correlations obtained for one intervention to another intervention proved not appropriate. The closest T2*/pO2 correlation was found for hypoxia and recovery. The interlayer comparison revealed closest T2*/pO2 correlations for the outer medulla and showed that extrapolation of results obtained for one renal layer to other renal layers must be made with due caution. For T2* to RBF relation, significant Spearman correlations were deduced for all renal layers and for all interventions. T2*/RBF correlations for the cortex and outer medulla were even superior to those between T2* and tissue pO2. The closest T2*/RBF correlation occurred during hypoxia and recovery. Close correlations were observed between T2* and kidney size during hypoxia and recovery and for occlusion and recovery. In both cases, kidney size correlated well with renal vascular conductance

  13. Effect of footwear on minimum foot clearance, heel slippage and spatiotemporal measures of gait in older women.

    Science.gov (United States)

    Davis, Annette M; Galna, Brook; Murphy, Anna T; Williams, Cylie M; Haines, Terry P

    2016-02-01

    Footwear has been implicated as a factor in falls, which is a major issue affecting the health of older adults. This study investigated the effect of footwear with dorsal fixation, slippers and bare feet on minimum foot clearance, heel slippage and spatiotemporal variables of gait in community dwelling older women. Thirty women participated (mean age (SD) 69.1 (5.1) years) in a gait assessment using the GaitRITE and Vicon 612 motion analysis system. Conditions included footwear with dorsal fixation, slippers or bare feet. Footwear with dorsal fixation resulted in improved minimum foot clearance compared to the slippers and bare feet conditions and less heel slippage than slippers and an increase in double support. These features lend weight to the argument that older women should be supported to make footwear choices with optimal fitting features including dorsal fixation. Recommendations of particular styles and features of footwear may assist during falls prevention education to reduce the incidence of foot trips and falls. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Infrared Thermometer: an accurate tool for temperature measurement during renal surgery

    Directory of Open Access Journals (Sweden)

    Giovanni Scala Marchini

    2013-07-01

    Full Text Available Purpose To evaluate infrared thermometer (IRT accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush and 10 without renal cooling (Group 2 - Warm Ischemia. Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT: immediate after clamping (T0, after 2 (T2, 5 (T5 and 10 minutes (T10. Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C. For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C. There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C. For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C. No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio

  15. Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

    International Nuclear Information System (INIS)

    Permpongkosol, Sompol; Link, Richard E.; Kavoussi, Louis R.; Solomon, Stephen B.

    2008-01-01

    During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0 o and sub-0 o C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0 o C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage

  16. Measurement of serum FT3 and FT4 in patients with chronic renal failure and its clinical significance

    International Nuclear Information System (INIS)

    Tan Qingling; Zhang Hui

    2003-01-01

    Objective: To investigate the changes of thyroid hormones in patients with chronic renal failure (CRF) and it's clinical significance. Methods: FT 3 , FT 4 and TSH levels were measured with radioimmunoassay for 42 CRF patients (42 CRF patients were subdivided into uremia and azotemia) and 18 cases of renal disease patients with a normal renal function. Results: Levels of FT 3 , FT 4 and TSH in uremia group and azotemia group were significantly lower than that of normal renal function group (P 3 , FT 4 and TSH in uremia group were remarkably lower than azotemia group (P 3 , FT 4 in patients with CRF can reflect the severity of renal function damage, and can also be an important prognosis index

  17. The kidneys play a central role in the clearance of rhGH in rats

    DEFF Research Database (Denmark)

    Vestergaard, Bill; Thygesen, Peter; Kreilgaard, Mads

    2016-01-01

    at treatment of patients with growth hormone disorders. The purpose of this study was to investigate the relative importance of the kidneys in the clearance of rhGH. The study employed a newly validated nephrectomy rat model and a population based pharmacokinetic approach to assess renal clearance of rh...... that renal clearance plays a pivotal role in the elimination of rhGH in rats....

  18. Renal volume assessed by magnetic resonance imaging volumetry correlates with renal function in living kidney donors pre- and postdonation: a retrospective cohort study.

    Science.gov (United States)

    Lange, Daniel; Helck, Andreas; Rominger, Axel; Crispin, Alexander; Meiser, Bruno; Werner, Jens; Fischereder, Michael; Stangl, Manfred; Habicht, Antje

    2018-07-01

    Renal function of potential living kidney donors is routinely assessed with scintigraphy. Kidney anatomy is evaluated by imaging techniques such as magnetic resonance imaging (MRI). We evaluated if a MRI-based renal volumetry is a good predictor of kidney function pre- and postdonation. We retrospectively analyzed the renal volume (RV) in a MRI of 100 living kidney donors. RV was correlated with the tubular excretion rate (TER) of MAG3-scintigraphy, a measured creatinine clearance (CrCl), and the estimated glomerular filtration rate (eGFR) by Cockcroft-Gault (CG), CKD-EPI, and modification of diet in renal disease (MDRD) formula pre- and postdonation during a follow-up of 3 years. RV correlated significantly with the TER (total: r = 0.6735, P volumetry might be an alternative technique for the evaluation of split renal function and prediction of renal function postdonation in living kidney donors. © 2018 Steunstichting ESOT.

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  5. Clinical value of measurement of pulmonary radioaerosol mucociliary clearance in the work up of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Nielsen, Kim Gjerum; Mortensen, Jann

    2015-01-01

    BACKGROUND: We aimed to evaluate and define the general clinical applicability and impact of pulmonary radioaerosol mucociliary clearance (PRMC) on the work up of patients suspected of having primary ciliary dyskinesia (PCD). In addition, we wanted to evaluate the accuracy of the reference values...... primarily to results from nasal ciliary function testing, to electron microscopic (EM) examination of the ultrastructure of the cilia, and to the final clinical diagnosis. RESULTS: Of the 239 patients, 27 ended up with a final clinical diagnosis of definitive PCD. No patients with a PRMC test...... of the entire lung. Its greatest strength is its ability to reject a suspected PCD diagnosis with great certainty. In our material, this accounted for 2/3 of referred patients. In addition, the test has a high rate of conclusive results. According to our analyses, reference equations on children would benefit...

  6. Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133Xe-clearance

    International Nuclear Information System (INIS)

    Hellem, S.; Jacobsson, L.S.; Nilsson, G.E.; Lewis, D.H.

    1983-01-01

    Blood flow in cancelleous bone with varying vascular density was investigated simultaneously with Laser Doppler Flowmeter (LDF) and 113 Xe-clearance. The cancellous bone subapical to 2 contralateral incisors in the mandibles of 17 young pigs was used as an experimental model. Light from a 2 mW He-Ne-laser was guided through an optical fibre to a flowmeter probe. Stainless steel probe-holders firmly inserted in the pulpal canals of the two incisors served as the probe entrance to cancellous bone for blood flow recording. Due to the Doppler effect, the light scattered by circulating blood cells undergoes a frequency shift. The back-scattered light picked up by optical fibres in the probe, was guided to a photosensitive device, where it was demodulated. After signal processing, a signal referred to as the Blood Flow Value (BFV) was recorded on a pen recorder. Rhythmical variations (vasomotion) in BFV with frequencies from 2-11 cycles/min were observed in 6% of recordings made initially after probeholder implantation, and in 34% of the recordings made 5 weeks later. On this occasion, a marked increase in BFV was recorded. Histological examination showed increased vascularity in the bone tissue. The reproducibility error of LDF was 7.4% and temporal changes in BFV, apart from vasomotion, were 8.3%, provided no injections or manipulations of the probe were made. Spatial variations in BFV were found to be related to the vascular density. 2 successive recordings by LDF from the same bone area were highly correlated (r=0.98). The corresponding figure for 2 logarithmic decay rates of locally injected 133 Xe was 0.76. No correlation between BFV and 133 Xe-clearance could be demonstrated. (author)

  7. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  8. Bone aluminum measurements in patients with end-stage renal disease

    International Nuclear Information System (INIS)

    Ellis, K.J.; Kelleher, S.P.

    1986-01-01

    Long-term use of aluminum-based phosphate binders and trace aluminum contamination of dialysate solution have led to increased body burden of this metal in patients with end-stage renal disease. Aluminum accumulates in bone and has been associated with the development of a renal osteodystrophy, called aluminum-induced osteomalacia. At present, bone biopsy is the method of diagnosis of this condition. When examined by quantitative histomorphometry, the aluminum accumulation was reported to correlate with the severity of the osteomalacia. This project was therefore undertaken to investigate the possibility of developing a non-invasive technique using neutron activation analysis for the direct in vivo assessment of bone aluminum levels. A bilateral exposure of the patient's hand is performed at the patient port of the Brookhaven Medical Research Reactor. The induced activity is then counted for 5 min using four 4'' x 4'' x 16'' NaI(T1) detectors arranged in a quasi-4! geometry. In addition to Al, Ca is also detected and serves as each individual's internal standard for the volume of bone mass irradiated. The Al/Ca ratio provides an index of the amount of elevated aluminum per unit bone mass. When this ratio is multiplied by the total body calcium value, an estimate of total skeletal aluminum is obtained. These measurements will be presented for a pilot study of ten asymptomatic renal patients

  9. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  10. Local measurement and numerical modeling of mass/heat transfer from a turbine blade in a linear cascade with tip clearance

    Science.gov (United States)

    Jin, Peitong

    2000-11-01

    Local mass/heat transfer measurements from the turbine blade near-tip and the tip surfaces are performed using the naphthalene sublimation technique. The experiments are conducted in a linear cascade consisting of five high-pressure blades with a central test-blade configuration. The incoming flow conditions are close to those of the gas turbine engine environment (boundary layer displacement thickness is about 0.01 of chord) with an exit Reynolds number of 6.2 x 105. The effects of tip clearance level (0.86%--6.90% of chord), mainstream Reynolds number and turbulence intensity (0.2 and 12.0%) are investigated. Two methods of flow visualization---oil and lampblack, laser light sheet smoke wire---as well as static pressure measurement on the blade surface are used to study the tip leakage flow and vortex in the cascade. In addition, numerical modeling of the flow and heat transfer processes in the linear cascade with different tip clearances is conducted using commercial software incorporating advanced turbulence models. The present study confirms many important results on the tip leakage flow and vortex from the literature, contributes to the current understanding in the effects of tip leakage flow and vortex on local heat transfer from the blade near-tip and the tip surfaces, and provides detailed local and average heat/mass transfer data applicable to turbine blade tip cooling design.

  11. Plasma clearance of sup(99m)Tc-N/2,4-dimethyl-acetanilido/iminodiacetate complex as a measure of parenchymal liver damage

    International Nuclear Information System (INIS)

    Studniarek, M.; Durski, K.; Liniecki, J.; Akademia Medyczna, Lodz

    1983-01-01

    Fifty-two patients were studied with various diseases affecting liver parenchyma. Any disorders of bile transport were excluded on the basis of dynamic liver scintigraphy using intravenously injected N/2,4-dimethyl acetanilid/iminodiacetate sup(99m)Tc complex (HEPIDA). The activity concentration of sup(99m)Tc-HEPIDA in plasma was measured from 5 through 60 min post injection. Clearance of the substance (Clsub(B)) was calculated from blood plasma disappearance curves and compared with results of 13 laboratory tests used conventionally for assessment of damage of the liver and its functional capacity; age and body weight was also included in the analysis. Statistical relations were studied using linear regression analysis of two variables, multiple regression analysis as well as multidimensional analysis of variance. It was demonstrated that sup(99m)Tc-HEPIDA clearance is a simple, accurate and repeatable measure of liver parenchyma damage. In males, values of Clsub(B) above 245 ml min - 1 /1.73 m 2 exclude hepatic damage with high probability; values below 195 ml min - 1 /1.73 m 2 indicate evident impairment of liver parenchyma function. (orig.) [de

  12. Snow clearance

    CERN Multimedia

    Mauro Nonis

    2005-01-01

    In reply to the numerous questions received, we should like to inform you of the actions and measures taken in an effort to maintain the movements of vehicles and pedestrians since the heavy snow fall on Sunday 23 January. Our contractor's employees began clearing the snow during the morning of Sunday 23 January on the main CERN sites (Meyrin, Prévessin), but an accident prevented them from continuing. The vehicle in question was repaired by Monday morning when two other vehicles joined it to resume snow clearing; priority was given to access points to the main sites and the LHC sites, as well as to the main roads inside the sites. The salt sprinklers were also brought into action that same day; the very low temperature during the night from Monday to Tuesday prevented the snow from melting and compacted the ice; the continuing cold during the day on Tuesday (-6°C at 10:00 on the Meyrin site) meant that all efforts to remove the ice were doomed to failure. In order to ensure more efficie...

  13. Lack of effect of non-steroid antiinflammatory drugs on lithium clearance and on delivery of tubular fluid to the loop of Henle in rats.

    Science.gov (United States)

    Lassen, E; Thomsen, K; Sørensen, S S; Pedersen, E B

    1986-11-01

    This paper examines a possible interaction between non-steroid antiinflammatory drugs (NSAI drugs) and renal lithium clearance in conscious, unoperated rats with diabetes insipidus (Brattleboro strain) and ordinary Wistar rats. The drugs were given with the food for 5 days before clearance determinations in the following daily doses per kg body weight: acetylsalicyclic acid 115 mg/kg, phenylbutazone 20 mg/kg, indomethacin 5 mg/kg, and penicillamine 65 mg/kg. None of the drugs affected the lithium clearance. Also urine flow, sodium clearance, potassium clearance, and prostaglandin E2 excretion remained unaffected by the treatments. The results suggest that a continued lowering of lithium clearance cannot be produced, at least not by administration of the drugs with the food. Since lithium clearance is a quantitative measure of the delivery of tubular fluid from the proximal tubules to the loop of Henle, the results also suggest that chronic administration of NSAI drugs does not influence delivery from the proximal tubules in rats. The lowering of lithium clearance observed by others after administration of the drugs by injection or by gastric tube may have been transient, lasting only for a short period after each administration.

  14. Dosing of cytotoxic chemotherapy: impact of renal function estimates on dose.

    Science.gov (United States)

    Dooley, M J; Poole, S G; Rischin, D

    2013-11-01

    Oncology clinicians are now routinely provided with an estimated glomerular filtration rate on pathology reports whenever serum creatinine is requested. The utility of using this for the dose determination of renally excreted drugs compared with other existing methods is needed to inform practice. Renal function was determined by [Tc(99m)]DTPA clearance in adult patients presenting for chemotherapy. Renal function was calculated using the 4-variable Modification of Diet in Renal Disease (4v-MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Cockcroft and Gault (CG), Wright and Martin formulae. Doses for renal excreted cytotoxic drugs, including carboplatin, were calculated. The concordance of the renal function estimates according to the CKD classification with measured Tc(99m)DPTA clearance in 455 adults (median age 64.0 years: range 17-87 years) for the 4v-MDRD, CKD-EPI, CG, Martin and Wright formulae was 47.7%, 56.3%, 46.2%, 56.5% and 60.2%, respectively. Concordance for chemotherapy dose for these formulae was 89.0%, 89.5%, 85.1%, 89.9% and 89.9%, respectively. Concordance for carboplatin dose specifically was 66.4%, 71.4%, 64.0%, 73.8% and 73.2%. All bedside formulae provide similar levels of concordance in dosage selection for the renal excreted chemotherapy drugs when compared with the use of a direct measure of renal function.

  15. Compartment model for the measurement of the effective renal plasma flow by radionuclidenephrography

    International Nuclear Information System (INIS)

    Ryabov, S.I.; Degtyareva, O.A.

    1988-01-01

    By reason of model ideas on hippuran kinetics radionuclide nephrograms were split up into a renal component and a component of the tissue background. New indices for the evaluation of renal function symmetry were proposed comprising the proportional determination of the effective renal plasma flow as well as of the symmetrical blood flow. For early diagnosis of latent renal dysfunction a new index is proposed characterizing the excretory renal transport as to local renal blood supply. Empirical indices of 120 patients suffering from chronic glomerulonephritis and pyelonephritis, resp., are stated

  16. Prediction of differential creatinine clearance in chronically obstructed kidneys by non-contrast helical computerized tomography

    International Nuclear Information System (INIS)

    Ng, Cheuk Fan; Chan, L.W.; Cheng, C.W.; Yu, S.C.H.; Wong, W.S.; Wong, K.T.

    2004-01-01

    Purpose: We investigate the use of non-contrast helical computerized tomography (NCHCT) in the measurement of differential renal parenchymal volume as a surrogate for differential creatinine clearance (Cr Cl) for unilateral chronically obstructed kidney. Materials And Methods: Patients with unilateral chronically obstructed kidneys with normal contralateral kidneys were enrolled. Ultrasonography (USG) of the kidneys was first done with the cortical thickness of the site with the most renal substance in the upper pole, mid-kidney, and lower pole of both kidneys were measured, and the mean cortical thickness of each kidney was calculated. NCHCT was subsequently performed for each patient. The CT images were individually reviewed with the area of renal parenchyma measured for each kidney. Then the volume of the slices was summated to give the renal parenchymal volume of both the obstructed and normal kidneys. Finally, a percutaneous nephrostomy (PCN) was inserted to the obstructed kidney, and Cr Cl of both the obstructed kidney (PCN urine) and the normal side (voided urine) were measured two 2 after the relief of obstruction. Results: From March 1999 to February 2001, thirty patients were enrolled into the study. Ninety percent of them had ureteral calculi. The differential Cr Cl of the obstructed kidney (%CrCl) was defined as the percentage of Cr Cl of the obstructed kidney as of the total Cr Cl, measured 2 weeks after relief of obstruction. The differential renal parenchymal volume of the obstructed kidney (%CTvol) was the percentage of renal parenchymal volume as of the total parenchymal volume. The differential USG cortical thickness of the obstructed kidney (%USGcort) was the percentage of mean cortical thickness as of the total mean cortical thickness. The Pearson's correlation coefficient (r) between %CTvol and %CrCl and that between %USGcort and %CrCl were 0.756 and 0.543 respectively. The regression line was %CrCl = (1.00) x %CTvol - 14.27. The %CTvol

  17. Prediction of differential creatinine clearance in chronically obstructed kidneys by non-contrast helical computerized tomography

    Directory of Open Access Journals (Sweden)

    Ng C.F.

    2004-01-01

    Full Text Available PURPOSE: We investigate the use of non-contrast helical computerized tomography (NCHCT in the measurement of differential renal parenchymal volume as a surrogate for differential creatinine clearance (CrCl for unilateral chronically obstructed kidney. MATERIALS AND METHODS: Patients with unilateral chronically obstructed kidneys with normal contralateral kidneys were enrolled. Ultrasonography (USG of the kidneys was first done with the cortical thickness of the site with the most renal substance in the upper pole, mid-kidney, and lower pole of both kidneys were measured, and the mean cortical thickness of each kidney was calculated. NCHCT was subsequently performed for each patient. The CT images were individually reviewed with the area of renal parenchyma measured for each kidney. Then the volume of the slices was summated to give the renal parenchymal volume of both the obstructed and normal kidneys. Finally, a percutaneous nephrostomy (PCN was inserted to the obstructed kidney, and CrCl of both the obstructed kidney (PCN urine and the normal side (voided urine were measured two 2 after the relief of obstruction. RESULTS: From March 1999 to February 2001, thirty patients were enrolled into the study. Ninety percent of them had ureteral calculi. The differential CrCl of the obstructed kidney (%CrCl was defined as the percentage of CrCl of the obstructed kidney as of the total CrCl, measured 2 weeks after relief of obstruction. The differential renal parenchymal volume of the obstructed kidney (%CTvol was the percentage of renal parenchymal volume as of the total parenchymal volume. The differential USG cortical thickness of the obstructed kidney (%USGcort was the percentage of mean cortical thickness as of the total mean cortical thickness. The Pearson's correlation coefficient (r between %CTvol and %CrCl and that between %USGcort and %CrCl were 0.756 and 0.543 respectively. The regression line was %CrCl = (1.00 x %CTvol - 14.27. The %CTvol

  18. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  19. The clinical significance of glomerular filtration rate measured by 99Tcm-diethylentriamine pentaacetic acid renal dynamic imaging in renal cercinoma patients before surgery

    International Nuclear Information System (INIS)

    Shao Xiaonan; Wang Yuetao; Wang Xiaosong; Chen Hailong

    2011-01-01

    Objective: To investigate the clinical significance of glomerular filtration rate (GFR) measured by 99 Tc m -diethylenetriamine pentaacetic acid ( 99 Tc m -DTPA) renal dynamic imaging in renal cell carcinoma (RCC) patients before surgery. Methods: There were 99 cases of RCC patients, 89 patients undergoing radical nephrectomy (RN) and 10 patients undergoing nephron-sparing surgery(NSS). 99 Tc m -DTPA renal dynamic imaging was performed for determining GFR before surgery. Make a comparison of GFR between RCC group and control group (normal kidney donors), RN group and NSS group. Make a comparison between GFR and serum creatinine in determining preoperative renal dysfunction of RCC patients. All of the data were analyzed by t-test and χ 2 -text. Results: Compared with control group, total GFR of RCC patients was lower, but there was no significant difference [(76.4±20.4)ml/min vs. (80.6±17.4)ml/min, t=0.650, P>0.05)]. Nineteen cases (19.2%) of RCC patients had preoperative renal dysfunction (total GFR 133μmol/L). There was no significant difference in GFR of neoplastic kidneys between RN group and NSS group [(34.1±11.7)ml/min vs.(37.9±11.9)ml/min, t=0.975, P>0.05]. GFR of contralateral kidneys was lower in NSS group than RN group [(32.7±10.3)ml/min vs. (39.6±10.1)ml/min, t=0.044, P 2 =6.808, P<0.01). Conclusion: GFR can provide the accurate information of both kidneys and single kidney before surgery, and this result possessed an important significance in choice of treatments. (authors)

  20. Pulsatility index of renal artery in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Baik, Soon Koo; Kim, Kwan Hyun; Jeong, Yon Soo; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok

    2000-01-01

    As one of non-invasive methods evaluating disorders of renal perfusion using Doppler ultrasonography, PI represents the characteristics of the Doppler waveform more accurately than RI, and even when renal perfusion is severely impaired, objective estimation is possible because of using the mean velocity in its calculation. The purpose of this study is to find out the clinical usefulness of PI for evaluating disorder of renal function in patients with liver cirrhosis. The subjects were 167 patients including 89 of Child A and B groups, 39 of Child C group, and 39 of control group. We compared PI, RI, creatinine, serum renin activity and aldosterone level between each groups, and investigated the relationships of PI with creatinine clearance, serum renin activity, and aldosterone level. Meal PI was 1.00 ± 0.15 in control group, 1.17 ± 0.22 in Child A and B groups, and 1.30 ± 0.28 in Child C group, which showed significant difference between each groups (p<0.05). Also RI, creatinine clearance, serum renin activity and aldosterone level revealed significant difference between each groups (p<0.05). PI showed significant negative relationships with creatinine clearance (p=0.009), serum renin activity (p=0.06), and aldosterone level (p=0.001). Measurement of PI by Doppler ultrasonography is a useful non-invasive method for evaluation renal dysfunction in patients with liver cirrhosis.

  1. Homer W. Smith's contribution to renal physiology.

    Science.gov (United States)

    Giebisch, Gerhard

    2004-01-01

    Homer Smith was, for three decades, from the 1930s until his death in 1962, one of the leaders in the field of renal physiology. His contributions were many: he played a major role in introducing and popularizing renal clearance methods, introduced non-invasive methods for the measurement of glomerular filtration rate, of renal blood flow and tubular transport capacity, and provided novel insights into the mechanisms of excretion of water and electrolytes. Homer Smith's contributions went far beyond his personal investigations. He was a superb writer of several inspiring textbooks of renal physiology that exerted great and lasting influence on the development of renal physiology. Smith's intellectual insights and ability for critical analysis of data allowed him to create broad concepts that defined the functional properties of glomeruli, tubules and the renal circulation. A distinguishing feature of Homer Smith's career was his close contact and collaboration, over many years, with several clinicians of his alma mater, New York University. For initiating these pathophysiological investigations, he is justly credited to have advanced, in a major way, our understanding of altered renal function in disease. Smith's lasting scientific impact is also reflected by a whole school of investigators that trained with him and who applied his methods, analyses and concepts to the study of renal function all over the world. So great was his influence and preeminence that Robert Pitts, in his excellent tribute to Homer Smith in the Memoirs of the National Academy of Science states that his death brought an end to what might be aptly called the Smithian Era of renal physiology.

  2. Hemodynamic Measurements for the Selection of Patients With Renal Artery Stenosis: A Systematic Review

    NARCIS (Netherlands)

    van Brussel, Peter M.; van de Hoef, Tim P.; de Winter, Robbert J.; Vogt, Liffert; van den Born, Bert-Jan

    2017-01-01

    Interventions targeting renal artery stenoses have been shown to lower blood pressure and preserve renal function. In recent studies, the efficacy of catheter-based percutaneous transluminal renal angioplasty with stent placement has been called into question. In the identification of functional

  3. [Anatomy character of renal artery and treatment of living-donor renal transplantation].

    Science.gov (United States)

    Zhang, Lei; Fei, Ji-guang; Chen, Li-zhong; Wang, Chang-xi; Deng, Su-xiong; Qiu, Jiang; Li, Jun; Chen, Guo-dong; Huang, Gang

    2009-12-15

    To study the anatomy characters of renal artery and the treatment of multiple arteries in living donor renal grafts. Records of 142 living donors were analyzed in our center. We analyzed the anatomic structure of renal arteries by DSA and CTA pre-transplantation. Thirty-one kidneys with multiple arteries were transplanted after reconstruction. Then clinical effects were compared between multiple-renal-arteries group (n=31) and single-renal-artery group (n=111). The incidence of multiple renal artery was 30.99%, and there was no difference between both sides (left kidney 22.54%, right kidney 22.13%). If the multiple artery occurred in left or right kidney, the incidence of the multiple artery occurred in the other side was 56.25% and 60.00%, respectively. The diameter of left main renal artery was more magnanimous (P=0.001) and the first branch was more closed to abdominal aorta (P=0.004). Operation time and warm/cool ischemia time were longer in the multiple-renal-arteries group. However, estimated blood loss, delayed graft function, acute rejection and flow rate of arcuate artery were similar in both groups, the same as serum creatinine and serum creatinine clearance rate on day 7, 1 month and 3 month post-operation. It was shown by repeated measures ANOVA that graft with multiple arteries didn't affect the tendency of renal function at early time post-operation. Comprehending the character of renal artery and accurate treatment of multiple artery anastomosis are critical for the effect of the living kidney transplantation.

  4. Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

    International Nuclear Information System (INIS)

    Mason, John A.; Burke, Kevin J.; Towner, Antony C.N.; Beaven, Graham; Spence, Robert

    2013-01-01

    This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  8. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  9. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

    Science.gov (United States)

    Romero, Cesar A; Cabral, Glauber; Knight, Robert A; Ding, Guangliang; Peterson, Edward L; Carretero, Oscar A

    2018-01-01

    Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min -1 ·100 g tissue -1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min -1 ·100 g tissue -1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min -1 ·100 g tissue -1 ; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.

  10. The Significance of Serum beta2-Microglobulin Measurement in Various Renal Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Koong, Sung Soo; Oh, Ha Yong; Han, Jin Suk; Lee, Jung Sang [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-03-15

    To evaluate change of serum beta{sub 2}-microglobulin concentration (sbeta{sub 2}-MG) and the usefulness of sbeta{sub 2}-MG and sbeta{sub 2}-MG/serum creatinine concentration (sCr) ratio in various renal diseases, sbeta{sub 2}-MG and sCr were measured in 25 normal controls and 90 patients of various renal diseases (16 cases of glomerulonephritis, 12 cases of acute renal failure, 8 cases of chronic renal failure, 24 cases of nephrotic syndrome, 15 cases of tubulointerstitial diseases and 15 cases of lupus nephritis) using Phadebas beta{sub 2}-Micro Test kits. The results were as follows; 1) In normal control, the mean value of sbeta{sub 2}-MG was 1.65+-0.41 mg/l and the mean value of sbeta{sub 2}-MG/sCr ratio was 0.14+-0.05. 2) In various renal diseases, the mean value of sbeta{sub 2}-MG was 6.74+-5.47 mg/l. The mean value of sbeta{sub 2}-MG/sCr ratio was 0.24+-0.11 and significantly elevated than that of normal contro1. (P<0.05). 3) The correlation between sbeta-2-MG and sCr in glomerular and tubulointerstitial disease was log sbeta{sub 2}-MG=0.90 log sCr-0.48 and its correlation coefficient was 0.78 (P<0.05). 4) In glomerular disease, the correlation between sbeta{sub 2}-MG and sCr was log sbeta{sub 2}-MG=0.89 log sCr-0.46 (r-0.76) and in tubulointerstitial disease, it was log sbeta{sub 2}-MG=0.95 1og sCr-0.59 (r-0.87). There was no significant difference between the two groups (p<0.05). 5) Among 32 cases of glomerular and tubulointerstitial disease patients, whose sCr was within normal range, 17 cases showed elevated sbeta{sub 2}-MG. The mean values of sbeta{sub 2}-MG/sCr ratio in these patients was 0.30+-0.14 and significantly elevated than that of normal control (p<0.05). 6) In 15 cases of lupus nephritis, 12 cases showed elevated sbeta{sub 2}-MG with normal sCr and 12 cases showed elevated sbeta{sub 2}-MG/sCr ratio. With above results, It was found that the sbeta{sub 2}-MG can be used as an index of glomerular filtration rate as in the case of sCr and thats

  11. Predictive factors of lower calyceal stone clearance after extracorporeal shockwave lithotripsy (ESWL): the impact of radiological anatomy.

    Science.gov (United States)

    Lin, Chih-Chieh; Hsu, Yen-Shen; Chen, Kuang-Kuo

    2008-10-01

    This study was carried out to determine whether or not there is a significant relationship between the radiologic anatomy of the lower calyx, as seen on preoperative intravenous urography (IVU), and the outcome of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for lower renal calyceal stones. Between June 1998 and April 2007, 112 patients with a solitary lower renal calyceal stone measuring 20 mm or less in size were enrolled in this retrospective study. Pretreatment IVU was reviewed for measuring the anatomical predictors, such as lower pole infundibular length, infundibular width (IW) and infundibulopelvic angle, while the stone location and size were determined on plain abdominal X-ray. All patients were treated with ESWL using a Siemens Lithostar Plus lithotriptor and were followed-up for the outcome of stone clearance 3 months after ESWL with plain abdominal X-ray films and ultrasonography. Three months after ESWL, only 49 (43.7%) patients were stone-free. Under multivariate analysis with logistic regression, smaller stone size (10 mm or less, p = 0.005) and greater IW (4 mm or more, p = 0.029) were significant favourable predictors for better stone clearance. In addition to the influence of stone size, lower pole anatomy, especially IW, has a significant impact on stone clearance for lower calyceal stone after ESWL.

  12. Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

    Science.gov (United States)

    Ascenti, Giorgio; Mileto, Achille; Krauss, Bernhard; Gaeta, Michele; Blandino, Alfredo; Scribano, Emanuele; Settineri, Nicola; Mazziotti, Silvio

    2013-08-01

    To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from χ (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses. • Enhancement of renal lesions is important when differentiating benign from malignant tumours. • Dual-energy CT offers measurement of iodine uptake rather than mere enhancement values. • Whole-tumour iodine quantification seems more accurate than standard CT enhancement measurements.

  13. Comparison of conventional versus three-dimensional ultrasound in fetal renal pelvis measurement and their potential prediction of neonatal uropathies

    NARCIS (Netherlands)

    Duin, L. K.; Nijhuis, J. G.; Scherjon, S. A.; Vossen, M.; Willekes, C.

    2016-01-01

    Objective: To establish a threshold value for fetal renal pelvis dilatation measured by automatic volume calculation (SonoAVC) in the third trimester of pregnancy to predict neonatal uropathies, and to compare these results with conventional antero-posterior (AP) measurement, fetal kidney 3D volume

  14. Hemodynamic Measurements for the Selection of Patients With Renal Artery Stenosis: A Systematic Review.

    Science.gov (United States)

    van Brussel, Peter M; van de Hoef, Tim P; de Winter, Robbert J; Vogt, Liffert; van den Born, Bert-Jan

    2017-05-22

    Interventions targeting renal artery stenoses have been shown to lower blood pressure and preserve renal function. In recent studies, the efficacy of catheter-based percutaneous transluminal renal angioplasty with stent placement has been called into question. In the identification of functional coronary lesions, hyperemic measurements have earned a place in daily practice for clinical decision making, allowing discrimination between solitary coronary lesions and diffuse microvascular disease. Next to differences in clinical characteristics, the selection of renal arteries suitable for intervention is currently on the basis of anatomic grading of the stenosis by angiography rather than functional assessment under hyperemia. It is conceivable that, like the coronary circulation, functional measurements may better predict therapeutic efficacy of percutaneous transluminal renal angioplasty with stent placement. In this systematic review, the authors evaluate the available clinical evidence on the optimal hyperemic agents to induce intrarenal hyperemia, their association with anatomic grading, and their predictive value for treatment effects. In addition, the potential value of combined pressure and flow measurements to discriminate macrovascular from microvascular disease is discussed. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. The renal handling of sodium and water is not affected by the standard-dose cisplatin treatment for testicular cancer

    DEFF Research Database (Denmark)

    Daugaard, G; Strandgaard, S; Holstein-Rathlou, N H

    1987-01-01

    Renal clearances of 51Cr-EDTA, lithium, sodium and potassium were measured before and after each of four consecutive treatment series with cisplatin in 15 men with testicular cancer. Since lithium is reabsorbed like sodium and water in the proximal tubules, but not reabsorbed to any measurable...... and all other parameters of glomerular filtration and renal sodium handling remained normal throughout the study (with the exception of a fall in fractional sodium excretion after the first treatment series). Plasma magnesium declined during all four treatment periods, signifying renal magnesium wasting....

  16. [Why? How? What for? We must measure the glomerular filtration].

    Science.gov (United States)

    Treviño-Becerra, Alejandro

    2010-01-01

    The measurement of the glomerular filtration shows the degree of the functional qualities and the proficiency of the renal system. Despite new technologies, at present the best accepted technique for measuring the glomerular filtration in most countries is the clearance of creatinine in 24 hour urine. The clearance of creatinine has the advantage that it is confident, easy to reproduce, without technical limitations and low cost.

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  19. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  20. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  1. Comparing renal function preservation after laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for clinical T1a renal tumor: using a 3D parenchyma measurement system.

    Science.gov (United States)

    Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin

    2017-05-01

    To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p renal parenchyma volume preservation (89.19 vs 84.27%, p renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.

  2. Neural regulation of the kidney function in rats with cisplatin induced renal failure

    Science.gov (United States)

    Goulding, Niamh E.; Johns, Edward J.

    2015-01-01

    Aim: Chronic kidney disease (CKD) is often associated with a disturbed cardiovascular homeostasis. This investigation explored the role of the renal innervation in mediating deranged baroreflex control of renal sympathetic nerve activity (RSNA) and renal excretory function in cisplatin-induced renal failure. Methods: Rats were either intact or bilaterally renally denervated 4 days prior to receiving cisplatin (5 mg/kg i.p.) and entered a chronic metabolic study for 8 days. At day 8, other groups of rats were prepared for acute measurement of RSNA or renal function with either intact or denervated kidneys. Results: Following the cisplatin challenge, creatinine clearance was 50% lower while fractional sodium excretion and renal cortical and medullary TGF-β1 concentrations were 3–4 fold higher in both intact and renally denervated rats compared to control rats. In cisplatin-treated rats, the maximal gain of the high-pressure baroreflex curve was only 20% that of control rats, but following renal denervation not different from that of renally denervated control rats. Volume expansion reduced RSNA by 50% in control and in cisplatin-treated rats but only following bilateral renal denervation. The volume expansion mediated natriuresis/diuresis was absent in the cisplatin-treated rats but was normalized following renal denervation. Conclusions: Cisplatin-induced renal injury impaired renal function and caused a sympatho-excitation with blunting of high and low pressure baroreflex regulation of RSNA, which was dependent on the renal innervation. It is suggested that in man with CKD there is a dysregulation of the neural control of the kidney mediated by its sensory innervation. PMID:26175693

  3. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  4. Comparative study between 99Tcm-MDP renal dynamic imaging and measurement of serum cystatin C in evaluation of glomerular function

    International Nuclear Information System (INIS)

    Ji Zeqiang; Miao Weibing

    2010-01-01

    Objective: To compare the difference between 99 Tcm-diethylenetriaminepentaacetic acid ( 99 Tc m -DTPA) renal dynamic imaging and measurement of serum cystatin C in evaluation of glomerular filtration rate (GFR). Methods: One hundred patients were selected at random, 38 cases with hypertension, 35 with nephrosis, 10 with arteriosclerosis obliterans, 9 with diabetes and 8 with other diseases. Evaluation of patients' GFR was made separately by 99 Tc m -DTPA renal dynamic imaging and measurement of serum cystatin C. Results: No significant difference of GFR was found between the two methods (t=1.591, P>0.05 ), and linear correlation was showed as well (r=0.809, P 99 Tc m -DTPA renal dynamic imaging could reveal the individual renal function and provide a more comprehensive evaluation of renal function while the measurement of serum cystatin C was simple and convenient, timesaving, economic, and more suit-able for screening patients' renal function clinically. (authors)

  5. Endothelial mineralocorticoid receptor ablation does not alter blood pressure, kidney function or renal vessel contractility

    DEFF Research Database (Denmark)

    Laursen, Sidsel B.; Finsen, Stine; Marcussen, Niels

    2018-01-01

    afferent arterioles. Urinary sodium excretion was determined by use of metabolic cages. EC-MR transgenics had markedly decreased MR expression in isolated aortic endothelial cells as compared to littermates (WT). Blood pressure and effective renal plasma flow at baseline and following AngII infusion...... vasculature and examined this by ablating the Nr3c2 gene in endothelial cells (EC-MR) in mice. Blood pressure, heart rate and PAH clearance were measured using indwelling catheters in conscious mice. The role of the MR in EC on contraction and relaxation was investigated in the renal artery and in perfused......Aldosterone blockade confers substantial cardiovascular and renal protection. The effects of aldosterone on mineralocorticoid receptors (MR) expressed in endothelial cells (EC) within the renal vasculature have not been delineated. We hypothesized that lack of MR in EC may be protective in renal...

  6. Well Preserved Renal Function in Children With Untreated Chronic Liver Disease.

    Science.gov (United States)

    Berg, Ulla B; Németh, Antal

    2018-04-01

    On the basis of studies with hepatorenal syndrome, it is widely regarded that renal function is impacted in chronic liver disease (CLD). Therefore, we investigated renal function in children with CLD. In a retrospective study of 277 children with CLD, renal function was investigated as glomerular filtration rate (GFR) and effective renal plasma flow (ERPF), measured as clearance of inulin and para-amino hippuric acid or clearance of iohexol. The data were analyzed with regard to different subgroups of liver disease and to the grade of damage. Hyperfiltration (>+2 SD of controls) was found in the subgroups of progressive familial intrahepatic cholestasis (44%), glycogenosis (75%), and acute fulminant liver failure (60%). Patients with biliary atresia, most other patients with metabolic disease and intrahepatic cholestasis, and those with vascular anomalies and cryptogenic cirrhosis had normal renal function. Decreased renal function was found in patients with Alagille's syndrome (64% < -2 SD). Increased GFR and ERPF was found in patients with elevated transaminases, low prothrombin level, high bile acid concentration, and high aspartate-aminotransferase-to-platelet ratio. Most children with CLD had surprisingly well preserved renal function and certain groups had even hyperfiltration. The finding that children with decompensated liver disease and ongoing liver failure had stable kidney function suggests that no prognostic markers of threatening hepatorenal syndrome were at hand. Moreover, estimation of GFR based on serum creatinine fails to reveal hyperfiltration.

  7. Pregnancy Increases the Renal Secretion of N1-methylnicotinamide, an Endogenous Probe for Renal Cation Transporters, in Patients Prescribed Metformin.

    Science.gov (United States)

    Bergagnini-Kolev, Mackenzie C; Hebert, Mary F; Easterling, Thomas R; Lin, Yvonne S

    2017-03-01

    N 1 -methylnicotinamide (1-NMN) has been investigated as an endogenous probe for the renal transporter activity of organic cation transporter 2 (OCT2) and multidrug and toxin extrusion proteins 1 and 2-K (MATE1 and MATE2-K). As pregnancy increased the renal secretion of metformin, a substrate for OCT2, MATE1, and MATE2-K, we hypothesized that the renal secretion of 1-NMN would be similarly affected. Blood and urine samples collected from women prescribed metformin for type 2 diabetes, gestational diabetes, and polycystic ovarian syndrome during early, mid, and late pregnancy ( n = 34 visits) and postpartum ( n = 14 visits) were analyzed for 1-NMN using liquid chromatography-mass spectrometry. The renal clearance and secretion clearance, using creatinine clearance to correct for glomerular filtration, were estimated for 1-NMN and correlated with metformin renal clearance. 1-NMN renal clearance was higher in both mid (504 ± 293 ml/min, P pregnancy (557 ± 305 ml/min, P pregnancy (269± 267, P pregnancy compared with postpartum (342 ± 283 versus 76 ± 92 ml/min, P Metformin renal clearance and 1-NMN renal clearance were positively correlated (r s = 0.68, P pregnancy due to increased glomerular filtration and net secretion by renal transporters. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.

  8. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland)); Sinjab, T.A.; Wlodarczyk, Z. (Dept. of Transplantology, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2009-04-15

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups.

  9. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    International Nuclear Information System (INIS)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W.; Sinjab, T.A.; Wlodarczyk, Z.

    2009-01-01

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups

  10. Analyse of influence elements in the process of dynamic renal imaging to measure glomerular filtration rate and effective renal plasma flow in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Yao Lixin; Li Zuofei; Liu Bo; Guo Leiming

    2010-01-01

    Objective: To detect the changes and clinical influence elements of radionuclide renal dynamic imaging to measure glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in patients with type 2 diabetes mellitus (T2DM). Methods: One hundred and eight patients with T 2 DM were divided into 4 groups according to the values of urinary albumin excretion rate (UAER): Group I: UAER -1 , 31 cases. Group II: UAER 20∼200μg·min -1 , 28 cases. Group III: UAER >200μg·min -1 , serum creatinine(SCr) 200μg·min -1 , SCr≥ 105μmol/L, 23 cases. 99 Tc m -diethylenetriamine pentaacetic acid and 99 Tc m -ethylenedicysteine renal dynamic imaging were performed in all patients. GFR, ERPF and renogram were derived simultaneously. The levels of blood creatinine, blood urea nitrogen, urine albumin, blood press, fasting blood insulin, glycosylated hemoglobin, fasting blood glucousewere measured in the four groups. Results: With the evolvement of diabetes nephropathy (DN), UAERs were gradually ascended and the values of GFR and ERPF was gradually descended, the former offered remarkable inverse correlation with the two latters (r 1 = -0.497, P 2 =-0.215, P 1 =1.8, t 2 =2.1, t 3 =1.9, P 4 =3.2, P<0.01). Multielement stepwise regression analyses assumed that age, systolic pressure, glycosylated hemoglobin and insulin resistance index offered inverse correlation with GFR and ERPF (coefficient of regression factor: -0.507, -0.874, -0.528, -0.587, -0.336, -0.697, -0.348, -0.371, P<0.01). Conclusion: GFR and ERPF were sensitive index reflecting the changes of DN.Hypertension and insulin resistance were independence risk factors to make the value of GFR and ERPF decreased in patients with DN. (authors)

  11. A fiber-optic technique for the measurement of contact angle in a clearance-fit pin-loaded hole

    Science.gov (United States)

    Prabhakaran, R.; Naik, R. A.

    1987-01-01

    A fiber-optic technique for measuring contact angle during pin loading of a specimen is proposed. The experimental design and procedures for loading a 49.8-mm-diameter instrumented pin into an quasi-isotropic graphite-epoxy specimen are described. The optical fiber was located just above the surface of the pin outer diameter in order to obtain accurate pin-hole contact-angle measurements at increasing load levels. The movement of the optical fiber through the no-contact, contact, and no-contact regions is discussed; the photodiode output decreased monotonically as the fiber moved from the no-contact to the contact region and then decreased monotonically as the fiber moved from the contact region to the no-contact region. Variations in the contact angle measurements are examined as function of applied load level. The measurements are compared to contact angle values obtained using a finite element analysis and an electrical technique; it is determined that the data correlate well.

  12. Piloting Psychology Annual Reviews as a Method of Measuring Psychological Distress and Quality of Life in Paediatric Renal Transplant Patients

    Directory of Open Access Journals (Sweden)

    Jade Bamford

    2016-01-01

    Full Text Available Psychosocial distress and poorer quality of life after renal transplantation are common in children and young people. This has implications for medication adherence and survival. Posttransplant psychology annual reviews were introduced in one Paediatric Renal Service in the UK as a means of measuring psychological distress and quality of life, as well as facilitating identification of patients and parents/carers who would benefit from psychological intervention. The process of completing posttransplant psychology annual reviews is discussed within this paper. The posttransplant psychology annual review appointments identified patients experiencing depression and/or anxiety and problems in quality of life. These assessments have led to appropriate referrals to, and engagement with, the renal psychology service as well as with community tier 3 child and adolescent mental health services. The posttransplant psychology annual review will continue to be completed at this UK site and discussions will be undertaken with other paediatric renal transplant services to consider whether these could be introduced at a national level to facilitate collection of longitudinal data regarding long-term psychosocial impact of paediatric renal transplantation and its effect on quality of life.

  13. High clearance phenotyping systems for season-long measurement of corn, sorghum and other row crops to complement unmanned aerial vehicle systems

    Science.gov (United States)

    Murray, Seth C.; Knox, Leighton; Hartley, Brandon; Méndez-Dorado, Mario A.; Richardson, Grant; Thomasson, J. Alex; Shi, Yeyin; Rajan, Nithya; Neely, Haly; Bagavathiannan, Muthukumar; Dong, Xuejun; Rooney, William L.

    2016-05-01

    The next generation of plant breeding progress requires accurately estimating plant growth and development parameters to be made over routine intervals within large field experiments. Hand measurements are laborious and time consuming and the most promising tools under development are sensors carried by ground vehicles or unmanned aerial vehicles, with each specific vehicle having unique limitations. Previously available ground vehicles have primarily been restricted to monitoring shorter crops or early growth in corn and sorghum, since plants taller than a meter could be damaged by a tractor or spray rig passing over them. Here we have designed two and already constructed one of these self-propelled ground vehicles with adjustable heights that can clear mature corn and sorghum without damage (over three meters of clearance), which will work for shorter row crops as well. In addition to regular RGB image capture, sensor suites are incorporated to estimate plant height, vegetation indices, canopy temperature and photosynthetically active solar radiation, all referenced using RTK GPS to individual plots. These ground vehicles will be useful to validate data collected from unmanned aerial vehicles and support hand measurements taken on plots.

  14. Measuring the quality of renal care: things to keep in mind when selecting and using quality indicators

    NARCIS (Netherlands)

    van der Veer, Sabine N.; van Biesen, Wim; Couchoud, Cécile; Tomson, Charles R. V.; Jager, Kitty J.

    2014-01-01

    This educational paper discusses a variety of indicators that can be used to measure the quality of care in renal medicine. Based on what aspect of care they reflect, indicators can be grouped into four main categories: structure, process, surrogate outcome and outcome indicators. Each category has

  15. Clearance of Sclerostin, Osteocalcin, Fibroblast Growth Factor 23, and Osteoprotegerin by Dialysis

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Mortensen, Ole H.; Axelsen, Mette

    2017-01-01

    Introduction: Fibroblast growth factor (FGF23), sclerostin, osteocalcin, and osteoprotegerin are important factors that control mineral bone metabolism. End-stage renal disease is associated with the pronounced dysregulation of mineral bone metabolism; however, the impact and clearance of mineral...

  16. Bumetanide kinetics in renal failure

    International Nuclear Information System (INIS)

    Pentikaeinen, P.J.P.; Pasternack, A.; Lampainen, E.; Neuvonen, P.J.; Penttilae, A.

    1985-01-01

    To study the effects of renal failure on bumetanide kinetics, the authors administered single intravenous doses of 1.0 mg/3.08 microCi 14 C-bumetanide to six healthy subjects and 22 patients with variable degrees of renal failure. The kinetics of 14 C-bumetanide and total 14 C were adequately described by a two-compartment open model in the control subjects and in the patients. The volume of the central compartment and the distribution t1/2 were of the same order in both groups, whereas the mean (+/- SE) volume at steady state was larger (22.1 +/- 1.6 and 16.9 +/- 1.0 L) and the elimination t1/2 was longer (1.9 +/- 0.2 and 1.4 +/- 0.1 hours) in patients with renal failure than in healthy controls. Bumetanide renal clearance was lower (10 +/- 3 and 90 +/- 13 ml/min) in patients than in subjects and correlated with creatinine clearance (r = 0.784) and log serum creatinine level (r = -0.843), whereas nonrenal clearance was significantly higher in the patients (153 +/- 14 and 99 +/- 6 ml/min). Bumetanide total plasma clearance did not significantly change. The non-protein-bound, free fraction of bumetanide was higher in patients and correlated with plasma albumin levels (r = -0.777). The kinetics of total 14 C showed similar but greater changes than those of 14C-bumetanide. Thus the most important changes in bumetanide kinetics in patients with renal failure are low renal clearance and a high free fraction, with a consequent increase in nonrenal clearance, volume of distribution, and elimination t1/2

  17. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    DEFF Research Database (Denmark)

    Kamper, A L; Thomsen, H S; Nielsen, S L

    1990-01-01

    function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51Cr-EDTA plasma clearance fell by 14% (P less than 0.01), but renal uptake of 99mTc-DMSA increased by 10% (P less than 0.01). It is concluded that DMSA in chronic renal failure is mainly taken......Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney...

  18. Metronidazole pharmacokinetics in patients with acute renal failure.

    Science.gov (United States)

    Somogyi, A A; Kong, C B; Gurr, F W; Sabto, J; Spicer, W J; McLean, A J

    1984-02-01

    The pharmacokinetics and metabolism of intravenous metronidazole were studied in six patients with acute renal failure. In two of the patients a single dose (500 mg) of metronidazole was administered, whereas in four patients the steady-state pharmacokinetics were studied after four days therapy of 500 mg twice daily. Plasma concentrations of metronidazole and its hydroxy and acetic acid metabolites were measured by a specific and sensitive HPLC method. The volume of distribution was 0.65 +/- 0.13 l/kg (mean +/- S.D.), elimination half-life was 9.9 +/- 2.5 h and total plasma clearance was 55.5 +/- 17.7 ml/min. Renal clearance was almost non-existent (1.4 +/- 1.4 ml/min), whereas non-renal clearance was 54.0 +/- 18.2 ml/min. Steady-state plasma concentrations of metronidazole were 15.3 +/- 3.8 mg/l, the hydroxy metabolite were 17.4 +/- 2.0 mg/l and the acetic acid metabolite were 1.2 +/- 0.8 mg/l. In the patients studied, a dosing regimen of 500 mg twice daily resulted in therapeutically adequate blood levels of metronidazole.

  19. Clinical nuclear medicine applications in Turkey and specific renal studies

    International Nuclear Information System (INIS)

    Erbas, B.

    2004-01-01

    Full text: Nuclear cardiology, nuclear oncology, pediatric nuclear medicine and nuclear endocrinology are the main application areas of clinical nuclear medicine in Turkey. Not only imaging studies, but also therapeutic application of radiopharmaceuticals is also performed at many institutes, such as hyperthyroidism treatment with radioiodine, thyroid cancer ablation and metastases treatment with radioiodine, radio synovectomy, metastatic pain therapy, and recently radioimmunotherapy of lymphomas. Almost all radionuclides and radiopharmaceuticals are obtained commercially from European countries, except 18-FDG which is obtained from two cyclotrons in Turkey. More than 30.000 renal procedures are performed at the University hospitals in a year. Pediatric age groups is approximately % 55 of patients. 99mTc-DTPA (%44), 99mTc-DMSA (%37), 99mTc-MAG3 (%17) and 99mTc-EC (%2) are the most commonly used radiopharmaceuticals for renal imaging. More than 6.000 vials of several pharmaceuticals are used for renal cortical scintigraphy (%35), dynamic renal imaging (%34), renal scintigraphy with diuretic (%27) and captopril scintigraphy (%4). Most common indication for renal cortical scintigraphy is detection of cortical scarring (%53). In addition, using single plasma sample method or gamma-camera method renal clearance measurements with 99mTc-MAG3 99mTc-DTPA have been used at some institutions

  20. Clinical nuclear medicine applications in Turkey and specific renal studies

    International Nuclear Information System (INIS)

    Erbas, B.

    2004-01-01

    Nuclear cardiology, nuclear oncology, pediatric nuclear medicine and nuclear endocrinology are the main application areas of clinical nuclear medicine in Turkey. Not only imaging studies, but also therapeutic application of radiopharmaceuticals is also performed at many institutes, such as hyperthyroidism treatment with radioiodine, thyroid cancer ablation and metastases treatment with radioiodine, radio synovectomy, metastatic pain therapy, and recently radioimmunotherapy of lymphomas. Almost all radionuclides and radiopharmaceuticals are obtained commercially from European countries, except 18-FDG which is obtained from two cyclotrons in Turkey. More than 30.000 renal procedures are performed at the University hospitals in a year. Pediatric age groups is approximately % 55 of patients. 99m Tc-DTPA (%44), 99m Tc-DMSA (%37), 99m Tc-MAG3 (%17) and 99m Tc-EC (%2) are the most commonly used radiopharmaceuticals for renal imaging. More than 6.000 vials of several pharmaceuticals are used for renal cortical scintigraphy (%35), dynamic renal imaging (%34), renal scintigraphy with diuretic (%27) and captopril scintigraphy (%4). Most common indication for renal cortical scintigraphy is detection of cortical scarring (%53). In addition, using single plasma sample method or gamma-camera method renal clearance measurements with 99m Tc-MAG3 99m Tc-DTPA have been used at some institutions. (author)

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  1. Practical utility of on-line clearance and blood temperature monitors as noninvasive techniques to measure hemodialysis blood access flow.

    Science.gov (United States)

    Fontseré, Néstor; Blasco, Miquel; Maduell, Francisco; Vera, Manel; Arias-Guillen, Marta; Herranz, Sandra; Blanco, Teresa; Barrufet, Marta; Burrel, Marta; Montaña, Javier; Real, Maria Isabel; Mestres, Gaspar; Riambau, Vicenç; Campistol, Josep M

    2011-01-01

    Access blood flow (Qa) measurements are recommended by the current guidelines as one of the most important components in vascular access maintenance programs. This study evaluates the efficiency of Qa measurement with on-line conductivity (OLC-Qa) and blood temperature monitoring (BTM-Qa) in comparison with the gold standard saline dilution method (SDM-Qa). 50 long-term hemodialysis patients (42 arteriovenous fistulas/8 arteriovenous grafts) were studied. Bland-Altman and Lin's coefficient (ρ(c)) were used to study accuracy and precision. Mean values were 1,021.7 ± 502.4 ml/min SDM-Qa, 832.8 ± 574.3 ml/min OLC-Qa (p = 0.007) and 1,094.9 ± 491.9 ml/min with BTM-Qa (p = NS). Biases and ρ(c) obtained were -188.8 ml/min (ρ(c) 0.58) OLC-Qa and 73.2 ml/min (ρ(c) 0.89) BTM-Qa. The limits of agreement (bias ± 1.96 SD) obtained were from -1,119 to 741.3 ml/min (OLC-Qa) and -350.6 to 497.2 ml/min (BTM-Qa). BTM-Qa and OLC-Qa are valid noninvasive and practical methods to estimate Qa, although BTM-Qa was more accurate and had better concordance than OLC-Qa compared with SDM-Qa. Copyright © 2010 S. Karger AG, Basel.

  2. A comparative study on approximate entropy measure and poincaré plot indexes of minimum foot clearance variability in the elderly during walking

    Directory of Open Access Journals (Sweden)

    Begg Rezaul K

    2008-02-01

    Full Text Available Abstract Background Trip-related falls which is a major problem in the elderly population, might be linked to declines in the balance control function due to ageing. Minimum foot clearance (MFC which provides a more sensitive measure of the motor function of the locomotor system, has been identified as a potential gait parameter associated with trip-related falls in older population. This paper proposes nonlinear indexes (approximate entropy (ApEn and Poincaré plot indexes of MFC variability and investigates the relationship of MFC with derived indexes of elderly gait patterns. The main aim is to find MFC variability indexes that well correlate with balance impairments. Methods MFC data during treadmill walking for 14 healthy elderly and 10 elderly participants with balance problems and a history of falls (falls risk were analysed using a PEAK-2D motion analysis system. ApEn and Poincaré plot indexes of all MFC data sets were calculated and compared. Results Significant relationships of mean MFC with Poincaré plot indexes (SD1, SD2 and ApEn (r = 0.70, p Conclusion Results have implication for quantifying gait dynamics in normal and pathological conditions, thus could be useful for the early diagnosis of at-risk gait. Further research should provide important information on whether falls prevention intervention can improve the gait performance of falls risk elderly by monitoring the change in MFC variability indexes.

  3. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  4. Relative Renal Blood Flow Measurements With Rb-82 and a Hybrid Gamma Camera Using a Pig Model

    Science.gov (United States)

    Pretorius, P. H.; Fung, L. C. T.; Schell, C. P.; King, M. A.

    2005-02-01

    We have successfully demonstrated with chronically implanted blood flow probes in a pig model that renal uptake of Rb-82 is indeed sensitive to acute renal blood flow changes. Two flow probes were placed around the left and right renal arteries in a surgical procedure nine weeks before the first Rb-82 measurements. Together with the flow probes, a flow restrictor was implanted around the left renal artery. Single bolus infusions of 6 mCi Rb-82 were used to study the uptake in the kidneys approximately 7 minutes apart in hybrid-image limited-angle acquisitions (stationary camera heads posterior and anterior of the pig) while changing the flow to the left kidney between acquisitions. The acquired data were reconstructed into 7.5-s frames using a maximum likelihood (ML) list-mode reconstruction algorithm exploiting timing signals inserted into the list every 0.25 s. Reconstructed data were orientated to coronal views before regions of interest (ROIs) were drawn over both kidneys with a separate background region for each. The data represented are noisy due to the reconstructed 7.5-s frames, and the total imaging time of 5 min (or 4 Rb-82 half-lives). We were able to show a steady decline in uptake of Rb-82 in the left kidney that correlates with the reduction in renal blood flow. The reduced blood flow to the left kidney affects the Rb-82 uptake to the right kidney slightly, while blood flow decreased up to 33%. Comparing the baseline renal blood flow of the left kidney obtained before and after the intervention indicates that some ischemia persists after blood flow was restored. Attenuation compensation better described the contour of the kidney but only scales the time activity curve without changing its shape.

  5. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.

    Science.gov (United States)

    Shimizu, Kazuhiro; Kosaka, Nobuyuki; Fujiwara, Yasuhiro; Matsuda, Tsuyoshi; Yamamoto, Tatsuya; Tsuchida, Tatsuro; Tsuchiyama, Katsuki; Oyama, Nobuyuki; Kimura, Hirohiko

    2017-01-10

    The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF). A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 99m Tc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF. The younger group showed significantly higher ATC-RBF (157.68 ± 38.37 mL/min/100 g) and shorter ATT (961.33 ± 260.87 ms) than the older group (117.42 ± 24.03 mL/min/100 g and 1227.94 ± 226.51 ms, respectively; P renal ASL-MRI as debated in brain imaging.

  6. Prediction of cardiovascular outcome by estimated glomerular filtration rate and estimated creatinine clearance in the high-risk hypertension population of the VALUE trial.

    Science.gov (United States)

    Ruilope, Luis M; Zanchetti, Alberto; Julius, Stevo; McInnes, Gordon T; Segura, Julian; Stolt, Pelle; Hua, Tsushung A; Weber, Michael A; Jamerson, Ken

    2007-07-01

    Reduced renal function is predictive of poor cardiovascular outcomes but the predictive value of different measures of renal function is uncertain. We compared the value of estimated creatinine clearance, using the Cockcroft-Gault formula, with that of estimated glomerular filtration rate (GFR), using the Modification of Diet in Renal Disease (MDRD) formula, as predictors of cardiovascular outcome in 15 245 high-risk hypertensive participants in the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial. For the primary end-point, the three secondary end-points and for all-cause death, outcomes were compared for individuals with baseline estimated creatinine clearance and estimated GFR or = 60 ml/min using hazard ratios and 95% confidence intervals. Coronary heart disease, left ventricular hypertrophy, age, sex and treatment effects were included as covariates in the model. For each end-point considered, the risk in individuals with poor renal function at baseline was greater than in those with better renal function. Estimated creatinine clearance (Cockcroft-Gault) was significantly predictive only of all-cause death [hazard ratio = 1.223, 95% confidence interval (CI) = 1.076-1.390; P = 0.0021] whereas estimated GFR was predictive of all outcomes except stroke. Hazard ratios (95% CIs) for estimated GFR were: primary cardiac end-point, 1.497 (1.332-1.682), P cause death, 1.231 (1.098-1.380), P = 0.0004. These results indicate that estimated glomerular filtration rate calculated with the MDRD formula is more informative than estimated creatinine clearance (Cockcroft-Gault) in the prediction of cardiovascular outcomes.

  7. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    Objective: Extracorporeal shock wave lithotripsy (ESWL) is one of the most commonly used procedures to remove renal calculi from the lower calyces. The aim of this work is to study the impact of radiological, anatomical and demographic factors on stone clearance after ESWL of lower calyceal calculi. Patients and ...

  8. Value of a simple technique for the measurement of total renal function and each kidney functions without requiring blood or urine samples

    International Nuclear Information System (INIS)

    Meyers, A.; Chachati, A.; Godon, J.P.; Rigo, P.

    1985-01-01

    The determination of renal uptake of 99m Tc DTPA and of 131 I Hippuran (as a percentage of the administred dose) at a time interval 1-3 minutes after tracer injection, is a rapid, accurate method for the measurement of total renal function and each kidney functions. Its clinical validity has been confirmed [fr

  9. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

    Science.gov (United States)

    Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky

    2014-06-01

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.

  10. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  11. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  12. The importance of accurate measurement of aortic stiffness in patients with chronic kidney disease and end-stage renal disease.

    Science.gov (United States)

    Adenwalla, Sherna F; Graham-Brown, Matthew P M; Leone, Francesca M T; Burton, James O; McCann, Gerry P

    2017-08-01

    Cardiovascular (CV) disease is the leading cause of death in chronic kidney disease (CKD) and end-stage renal disease (ESRD). A key driver in this pathology is increased aortic stiffness, which is a strong, independent predictor of CV mortality in this population. Aortic stiffening is a potentially modifiable biomarker of CV dysfunction and in risk stratification for patients with CKD and ESRD. Previous work has suggested that therapeutic modification of aortic stiffness may ameliorate CV mortality. Nevertheless, future clinical implementation relies on the ability to accurately and reliably quantify stiffness in renal disease. Pulse wave velocity (PWV) is an indirect measure of stiffness and is the accepted standard for non-invasive assessment of aortic stiffness. It has typically been measured using techniques such as applanation tonometry, which is easy to use but hindered by issues such as the inability to visualize the aorta. Advances in cardiac magnetic resonance imaging now allow direct measurement of stiffness, using aortic distensibility, in addition to PWV. These techniques allow measurement of aortic stiffness locally and are obtainable as part of a comprehensive, multiparametric CV assessment. The evidence cannot yet provide a definitive answer regarding which technique or parameter can be considered superior. This review discusses the advantages and limitations of non-invasive methods that have been used to assess aortic stiffness, the key studies that have assessed aortic stiffness in patients with renal disease and why these tools should be standardized for use in clinical trial work.

  13. Recombinant human erythropoietin in humans down-regulates proximal renal tubular reabsorption and causes a fall in glomerular filtration rate

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Aachmann-Andersen, Niels Jacob; Oturai, Peter

    2010-01-01

    HuEPO for 28 days in doses raising the hematocrit to 48.3 (4.1) %. Renal clearance studies with urine collections (N = 8) were done at baseline and at days 4, 11, 29, and 42. Glomerular filtration rate (GFR) was measured by (51)Cr-EDTA. Renal clearance of lithium (C(Li)) was used as an index of proximal...... tubular outflow and to assess segmental renal tubular handling of sodium and water. rHuEPO-induced increases in hematocrit occurred from day 10 onwards and was caused by both an increase in red cell volume and a fall in plasma volume. Well before that (from day 2 and throughout the treatment time), r...... and water (APR = GFR - C(Li), P

  14. Comparative study of unilateral renal tubule function using 131I-o-hippuran and sup(99m)Tc-dimercaptosuccinic acid with regard to renal depth and excretion relations

    International Nuclear Information System (INIS)

    Moser, E.A.

    1980-01-01

    Good agreement was found between sonographic and nuclear renal depth data. In patients with undisturbed postrenal urodynamics, the data of unilateral renal clearance obtained by DMSA and OIH are in good agreement after depth correction. With OIH, the activity measured for unilateral congestion kidneys was higher than with DMSA. However, both methods may overestimate unilateral congestion kidneys. The OIH method should be favoured in nuclear renal diagnostics. In patients with mobile kidneys, the lower function calculated for the ptotic kidney can be evaluated only after depth correction. To reduce the radiation exposure, renal depth data required for depth correction should be determined by sonographic methods. The peak/scatter method of renal depth determination cannot be employed in practice in the 131 J hippurane test; in the sup(99m)Tc-DMSA test, sufficient agreement between peak/scatter quotient and renal depth is only obtained after background correction. The result does not warrant the tedious procedure. DMSA studies of the kidneys are appropriate in the following cases: 1. Emergency studies of unilateral renal function in cases of acute anuria due to postrenal stoppage. 2. Assessment of unilateral parenchymal function in patients with mobile kidneys if the ptotic kidney cannot be imaged by sonographic processes. 3. Search for extremely displaced renal tissue. 4. Unilateral renal function studies in patients with unilateral kidney diseases if the postrenal situation and the global renal function can be assessed by other methods. (orig./MG) [de

  15. Quantitative measurement of bone mineral contents in patients with senile osteoporosis and chronic renal failure

    International Nuclear Information System (INIS)

    Fukuda, Teruo

    1985-01-01

    Computed tomography using X-ray (XCT) and single photon emission computed tomography (SPECT) using sup(99m)Tc-MDP of the skull were performed in patients with ''senile osteoporosis'' and with chronic renal failure, in order to quantitatively determine bone mineral contents. XCT: In females with postmenopausal osteoporosis (6th decade), the EMI number of frontal bone was significantly low compared with that of control group, of the same age. The EMI number in ''senile osteoporosis'' correlated with the value of serum 25 (OH) D and 1 α - 25 (OH) 2 D. The EMI number in hemodialyzed patients was significantly low compared with that in the control group. On the other hand, the EMI number in non-hemodialyzed chronic renal failure patients showed no significant difference compared with findings in the control group. The EMI number of the frontal bone in patients with partial parathyroidectomy showed a slight rise compared with findings before surgery. Bone scintigram, Bone scan SPECT: Positive scan was seen in patients with long term hemodialysis and increased values of serum Alk-Pase and PTH were often apparent. Scintigraphic improvement in patients with renal osteodystrophy treated with vitamin D 3 showed a good correlation with improvement in serum Alk-Pase values. On SPECT, frontal bone activity in patients with renal osteodystrophy was significantly high compared with that in the control group. In case of renal osteodystrophy treated with partial parathyroidectomy, the frontal bone activity was markedly decreased compared with findings before surgery. (J.P.N.)

  16. Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance.

    Science.gov (United States)

    Taylor, A; Manatunga, A; Morton, K; Reese, L; Prato, F S; Greenberg, E; Folks, R; Kemp, B J; Jones, M E; Corrigan, P E; Galt, J; Eshima, L

    1997-07-01

    To evaluate an improved camera-based method for calculating the clearance of technetium-99m mercaptoacetyltriglycine (MAG3) in a multicenter trial. Tc-99m MAG3 scintigraphy was performed in 49 patients at three sites in the United States and Canada. The percentage of the injected dose of Tc-99m MAG3 in the kidney at 1-2, 1.0-2.5, and 2-3 minutes after injection was correlated with the plasma-based Tc-99m MAG3 clearances. The data were combined with the results obtained in 20 additional patients in a previously published pilot study. Regression models correlating the plasma-based Tc-99m MAG3 clearance with the percentage uptake in the kidney for each time interval were developed; there was no statistically significant difference among sites in the regression equations. Correction for body surface area statistically significantly (P time interval. For the 1.0-2.5-minute interval, the body surface area-corrected correlation coefficient for the four combined sites was .87, and it improved to .93 when one outlier was omitted from the analysis. Similar results were obtained with the other time intervals. Independent processing by two observers showed no clinically important differences in the percentage dose in the kidney or in relative function. An improved camera-based method to calculate the clearance of Tc-99m MAG3 was validated in a multicenter trial.

  17. Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia.

    Science.gov (United States)

    Zizer, Eugen; Seufferlein, Thomas; Hänle, Mark Martin

    2017-02-01

    Introduction and aims  High-resolution esophageal manometry (HRM) has improved the diagnostic work-up of esophageal motility disorders. Simultaneous evaluation of bolus clearance delivers useful information about the function of tubular esophagus. We assessed bolus clearance in a combined HRM-impedance examination for esophagogastric junction outflow obstruction (EGJOO) in comparison to achalasia patients. The collected data were assessed in a retrospective analysis. Patients and methods  After gastroscopy excluded a mechanical esophageal or gastric obstruction, 142 consecutive patients underwent combined HRM-impedance examination. The assessment and interpretation of the manometry results were done according to the Chicago Classification of esophageal motility disorders v3.0. After classifying the motility disorder, the evaluation of bolus clearance was done according to published studies. Results  All patients with achalasia (n = 24) showed a significantly impaired bolus clearance (achalasia cases. This might be helpful as an additional tool to differentiate between achalasia and EGJOO patients. Furthermore, the role of the combined impedance-HRM investigation for early diagnosis of achalasia in "pre-achalasia" condition or in evaluation of potential progress of EGJOO to achalasia should be evaluated in a prospective study. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Is the gravity effect of radiographic anatomic features enough to justify stone clearance or fragments retention following extracorporeal shock wave lithotripsy (SWL).

    Science.gov (United States)

    Mustafa, Mahmoud

    2012-08-01

    We determined whether the gravity effect of radiographic anatomic features on the preoperative urography (IVP) are enough to predict fragments clearance after shock wave lithotripsy (SWL). A Total of 282 patients with mean age 45.8 ± 13.2 years (189 male, 93 female), who underwent SWL due to renal calculi between October 2005 and August 2009 were enrolled. The mean calculi load was 155.72 ± 127.66 mm². The patients were stratified into three groups: patients with pelvis calculi (group 1); patients with upper or middle pole calculi (group 2) and patients with lower pole calculi (group 3). Three angles on the pretreatment IVP were measured: the inner angle between the axis of the lower pole infundibular and ureteropelvic axis (angle I); the inner angle between the lower pole infundibular axis and main axis of pelvis-ureteropelvic (UP) junction point (angle II) and the inner angle between the lower pole infundibular axis and perpendicular line (angle III). Multivariate analysis was used to define the significant predictors of stone clearance. The overall success rate was 85.81%. All angles, sessions number, shock waves number and stone burden were significant predictors of success in patients in group 1. However, in group 2 only angle II and in group 3 angles I and II had significant effect on stone clearance. Radiographic anatomic features have significant role in determining the stone-free rate following satisfactory fragmentation of renal stones with SWL. The measurement of infundibulopelvic angle in different manner helps to predict the stone-free status in patients with renal calculi located not only in lower pole, but also in renal pelvis and upper or middle pole. Gravity effect is not enough to justify the significant influence of the radiographic anatomic features on the stone clearance and fragments retention after SWL.

  19. Uses and limitations of renal scintigraphy in renal transplantation monitoring

    International Nuclear Information System (INIS)

    Heaf, J.G.; Iversen, J.

    2000-01-01

    The value of thrice weekly technetium-99m mercaptoacetyltriglycine renography after renal transplantation was investigated in 213 consecutive transplants. A grading system was used: 0 = normal renogram; 1 = normal uptake, reduced excretion; 2 = normal uptake, flat excretion curve; 3 = rising curve; 4 = reduced rate of uptake, rising curve and reduced absolute uptake; 5 = minimal uptake. The initial renogram grade (RG) was primarily a marker of ischaemic damage, being poorer with cadaver donation, long cold ischaemia (>24 h), and high donor and recipient age. High primary RG predicted primary graft non-function, long time to graft function, low discharge Cr EDTA clearance and low 1- and 5-year graft survival. Discharge RG predicted late (>6 months) graft loss. RG was highly correlated (P<0.001) with creatinine and creatinine clearance, and changes in RG were correlated with changes in renal function. A change in RG of 0.5 was non-specific, while a change of 1 or more predicted clinical complications in 95% of cases. The negative predictive value was low (58%). RG change antedated clinical diagnosis in only 38% of cases, and in only 14% of acute rejections did an RG change of 1 or more antedate a rising creatinine. RG did not contribute to the differential diagnosis between acute rejection, acute tubulointerstitial nephropathy and cyclosporine toxicity. In conclusion, an initial renography after transplantation is valuable as it measures ischaemic damage and predicts duration of graft non-function and both short and long-term graft survival. A review of the literature suggests that the indication for serial scintigraphic monitoring for functioning grafts is less certain: the diagnostic specificity is insufficient for it to be the definitive investigation for common diagnostic problems and it does not give sufficient advance warning of impending problems. (orig.)

  20. Technetium-99m DTPA renal flow studies in Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nally, J.V.; Clarke, H.S.; Windham, J.P.; Grecos, G.P.; Gross, M.L.; Potvin, W.J.

    1985-01-01

    Computer-assisted dynamic renal studies were performed on a group of 14 mongrel dogs before and after the induction of unilateral renal artery stenosis. Ninety-second technetium-99m diethylenetriaminepentaacetic acid ([/sup 99m/Tc]DTPA), 15-min [/sup 99m/Tc]DTPA, and 30-min iodine-131 orthoiodohippurate ([ 131 I]hippuran) time-activity curves were analyzed and correlated with reduction of renal blood flow as measured by electromagnetic flow probe and PAH clearance techniques. For blood flow reductions greater than 33%, the [/sup 99m/Tc]DTPA studies were judged diagnostic of unilateral renal artery stenosis in all cases, whereas the [ 131 I]hippuran time-activity curves were indicative of stenosis in only six of ten studies. Thus, in this model we find the computer-assisted 90-sec [/sup 99m/Tc]DTPA renal flow study to be superior to conventional [ 131 I]hippuran renography in the diagnosis of moderate-to-serve unilateral renal artery stenosis

  1. The measurement of tracheo-bronchial mucociliary clearance with 99mTc-DTPA aerosol scintigraphy and its preliminary application in COPD patients

    International Nuclear Information System (INIS)

    Li, L.; Kuang, A.; Deng, H.; Li, X.

    2000-01-01

    Mucocoiliary clearance of respiratory channels is one of the important mechanisms guarding against retention of foreign particles within the lungs. Disorders of the mucociliary transport system play a major role among non-respiratory function in causing congenital and acquired bronchial disease. Thus, objective assay of the system is essential to recognizing and understanding abnormalities. In the present paper, a simple, noninvasive, and reliable in vivo method of monitoring mucociliary clearance function is reported. 18 healthy subjects and 32 COPD patients were studied with 99m Tc-DTPA aerosol scintigraphy. Monitoring was performed by visual inspection (cinescintigraphy, to observe the distribution of 99m Tc-DTPA particles and the movement of radiomucous 'hot bolus') and quantitative analysis (two indexes were utilized: the first is airway clearance ratio (ACR); the second is mucociliary clearance rate (MCC), i.e. speed of advances of mucous bolus, calculated reported by Zwas). Siemens 3700 SPECT, 64 X 64 byte mode, zoom 2. Sequential images (frame/60s) were obtained for 120 minutes. The deposition pattern of 99m Tc-DTPA particles in normal subjects was uniform. The deposition pattern in COPD patients demonstrated in general a centrally located distribution with major retention in the proximal airways. Four abnormal mucous transport patterns were regionally observed: stasis, regurgitation, straying and spiral or zigzag transport. Statistical analysis showed there was a significant difference of ACR between healthy subjects and COPD patients at different time points (P<0.05). The MCC in healthy subjects and COPD patients was 3.89±0.92 mm/min and 1.32±0.59 mm/min respectively. The method of assaying tracheo-bronchial mucociliary clearance reported here is simple and objective. It has not only the advantage of visual inspection and quantitative analysis, but also has a potential usefulness in studying other bronchial diseases and evaluating of therapeutic

  2. Current status and methodological aspects on the measurement of glomerular filtration rate

    International Nuclear Information System (INIS)

    Froissart, M.; Hignette, C.; Kolar, P.; Prigent, A.; Paillard, M.

    1995-01-01

    Determination of the glomerular filtration rate (GFR) contribute to our understanding of kidney physiology and pathophysiology . Moreover, determination of GFR is of clinical importance in assessing the diagnosis and the progression of renal disease. The purpose of this article is to review the technical performance and results of GFR measurements, including the classical inulin clearance technique and more recent alternative clearance techniques using radioisotope-labelled filtration markers, bolus infusion and spontaneous bladder emptying. Some simplified techniques avoiding urinary collection are also described. We conclude that estimation of GFR from renal and in some cases plasmatic clearances is accurate and more convenient than the classical inulin clearance technique. Such measurements of GFR should be included both in clinical practice and clinical research. (authors). 80 refs., 5 figs., 1 tab

  3. Assessment of glomerular filtration rate measurement with plasma sampling: a technical review.

    Science.gov (United States)

    Murray, Anthony W; Barnfield, Mark C; Waller, Michael L; Telford, Tania; Peters, A Michael

    2013-06-01

    This article reviews available radionuclide-based techniques for glomerular filtration rate (GFR) measurement, focusing on clinical indications for GFR measurement, ideal GFR radiopharmaceutical tracer properties, and the 2 most common tracers in clinical use. Methods for full, 1-compartment, and single-sample renal clearance characterization are discussed. GFR normalization and the role of GFR measurement in chemotherapy dosing are also considered.

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... NACFC Carolyn and C Richard Mattingly Leadership in Mental Health Care Award Mary M. Kontos Award NACFC Reflections ... help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. ... Instagram Email Find a Clinical Trial Help us blaze ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  8. Intensified Multifactorial Intervention in Type 2 Diabetes and Microalbuminuria Reduces End Stage Renal Disease and Mortality

    DEFF Research Database (Denmark)

    Oellgaard, Jens; Gæde, Peter; Rossing, Peter

    2016-01-01

    -label trial. Duration of the intervention was 8 years, where after all patients were recommended intensified treatment. Total follow-up of up to 21 years of 24 hour urinary albumin excretion rate and GFR (51Cr-EDTA-clearance) assessed at 6 study visits. Information on end stage renal disease (ESRD......) and mortality was obtained from national registries. Outcome measures were progression to macroalbuminuria (>300 mg/24h), decline-rates of GFR and progression to end stage renal disease (ESRD) or death. Results: Progression to macroalbuminuria was reduced in the original intensive-therapy group with a hazard...

  9. Early experience with repeated determinations of 131-I-hipuran clearance-equivalent during pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, R; Stoll, W; Arndt, J

    1981-07-01

    Serial observations of ureteric and renal function during pregnancy were carried out by using isotope clearances; renal scintigraphy was performed for the first examination and isotope nephrography subsequently. The results of both types of examination are tabulated. It is shown that these procedures provide the necessary information on renal and ureteric function, given the indications which we have listed. The information concerns both kidneys or can be confined to a single kidney.

  10. Frequency and causes of discrepancy between Kt/V and creatinine clearance.

    Science.gov (United States)

    Satko, S G; Burkart, J M; Bleyer, A J; Jordan, J R; Manning, T

    1999-01-01

    This study examines the frequency of discrepancy between Kt/V urea and creatinine clearance (Ccr) measurements in patients on peritoneal dialysis (PD) and the reasons for this discrepancy. Nonrandomized, retrospective data analysis. Single PD unit of a university teaching hospital. All adult patients receiving PD at our center from January 1995 to December 1996. Actual (a) and desired (d) body weight (BW) were used to calculate urea volume of distribution (V) and body surface area (BSA). Patients were divided into four groups based upon their total small solute clearances (Kt/V and Ccr, normalized by actual weight) and three additional groups based upon actual/desired (a/d) body weight ratio. An additional analysis was performed for the subset of anuric patients. Data collected for all patients included the following: total Kt, total Ccr, 4-hour dialysate/ plasma (D/P) creatinine, serum albumin concentration, duration of PD, actual body weight, age, and height. Twenty-three percent of the clearance measurements in our study were discrepant, defined as having values for either Kt/V or Ccr (but not both) above the accepted targets of Kt/V > or = 2.0/wk and Ccr > or = 60 L/wk/ 1.73 m2. Patients with both values above target are more likely to have higher residual renal function. Patients who are significantly less than BWd and patients on PD for a longer time are more likely to have adequate Kt/V but not Ccr. Furthermore, patients who are less than 90% or greater than 110% of BWd have markedly different values for Kt/V and Ccr when BWa versus BWd values are used. Kt/V and Ccr values are frequently discrepant; a number of factors affect these two measurements to varying degrees, including weight, degree of residual renal function, and duration of PD.

  11. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  12. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  13. Creatinine Clearance Is Not Equal to Glomerular Filtration Rate and Cockcroft-Gault Equation Is Not Equal to CKD-EPI Collaboration Equation.

    Science.gov (United States)

    Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto

    2016-12-01

    Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Extension of the Calvert formula to patients with severe renal insufficiency.

    Science.gov (United States)

    Oguri, Tomoyo; Shimokata, Tomoya; Ito, Isao; Yasuda, Yoshinari; Sassa, Naoto; Nishiyama, Masami; Hamada, Akinobu; Hasegawa, Yoshinori; Ando, Yuichi

    2015-07-01

    The Calvert formula was derived from the study among patients with glomerular filtration rates (GFRs) of 33-135 ml/min, and it remains unclear whether the formula can be used to calculate optimal and safe dosages of carboplatin in patients with severe renal insufficiency. We evaluated the utility of this formula in patients with severe renal insufficiency. For pharmacokinetic analysis, we studied nine adult Japanese patients with advanced cancer who had an estimated GFR of lower than 30 ml/min/1.73 m(2), as calculated by the Japanese equation for estimating GFR, or who were receiving hemodialysis. The dose of carboplatin was calculated with the Calvert formula, in which GFR was measured by inulin clearance or was assumed to be 0 in patients requiring hemodialysis. Hemodialysis was started 23 h after the end of carboplatin infusion. Although there was a significant correlation between the estimated and measured carboplatin clearance, the estimated clearance was consistently higher than the measured clearance [mean prediction error ± standard deviation = 41.0 ± 26.3 %] in all seven patients with renal insufficiency (GFR, median 21.4, range 7.8-31.4 ml/min) and in the two hemodialysis patients. Actual areas under the concentration-time curve (AUC) (mg/ml min) were 5.4, 5.7, 6.2, and 9.0 for the four patients with a target AUC (mg/ml min) of 5; 5.7, 6.2, and 7.1 for the three patients with a target AUC (mg/ml min) of 4; and 5.1 and 8.7 for the two hemodialysis patients with a target AUC (mg/ml min) of 5. The measured clearance of carboplatin ranged from 23.0 to 51.3 ml/min in the seven patients not receiving hemodialysis. The pre-hemodialysis carboplatin clearance in the hemodialysis patients was 20.5 and 11.1 ml/min, respectively. For adult patients with severe renal insufficiency, the Calvert formula causes carboplatin overdosing by overestimating the carboplatin clearance.

  15. Development of formulas for the estimation of renal depth and application in the measurement of glomerular filtration rate in Koreans

    International Nuclear Information System (INIS)

    Yoo, Ie Ryung; Kim, Sung Hoon; Chung, Yong An

    2000-01-01

    There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F=167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the men (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height) +0.002 (age) +2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for for MLK,12.936 (weight/height)+0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately

  16. MAG3 diuresis renography and output efficiency measurement in renal transplant patients

    International Nuclear Information System (INIS)

    Spicer, T.; Gruenewald, S.; Chi, K.K.; Larcos, G.; Farlow, D.; Choong, K.; Chapman, J.

    1997-01-01

    Full text: Urinary tract obstruction following renal transplantation often presents a diagnostic dilemma, as some patients with equivocal investigations subsequently show improvement following stenting. The purposes of this study were to (1) establish a normal range of renal output efficiency (ROE) in transplants, and (2) assess the usefulness of MAG3 diuresis renography and ROE in suspected allograft obstruction. Twenty-two renal transplant patients with stable function and no evidence of hydronephrosis on serial ultrasound had a diuretic MAG3 scan with calculation of ROE. Three patients with proven graft obstruction underwent the same scanning procedure. Methodology was as follows: (1) 60 MBq of 99m Tc-DTPA GFR was performed (single injection-dual blood sample method); (2) patients were then prehydrated with either oral or IV fluid; (3) 10 min prior to scanning, intravenous Frusemide 20-80 mg (dose depending on renal function) was injected, and then (4) 200 MBq of MAG3 for a 20 min scan. The studies were then qualitatively and quantitatively reviewed to assess uptake and excretion, and the ROE was calculated. The mean ROE for the twenty-two normal renal transplant patients was 85.7% ± 4.1% (range 78 - 90%). Technetium-99m-DTPA GFR was 55.5 mL/min/1.73m 2 (range 27 to 83). The MAG3 scans in the three obstructed patients were equivocal for obstruction but the ROE values of 59%, 68% and 75% were more than 2.5 standard deviations below our calculated normal mean. The 99m Tc-DTPA GFRs were 61,17 and 57 mL/min/1.73m 2 , respectively. Thus, in normal grafts the ROE should exceed 78 per cent. Our data suggest that ROE may be a useful addition to standard scintigraphic parameters in diagnosis of graft obstruction

  17. Accurate perioperative flow measurement of the portal vein and hepatic and renal artery: A role for preoperative MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Vermeulen, Mechteld A.R., E-mail: mar.vermeulen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Ligthart-Melis, Gerdien C., E-mail: g.ligthart-melis@vumc.nl [Department of Internal Medicine, Dietetics and Nutritional Sciences, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Buijsman, René, E-mail: renebuysman@gmail.com [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Siroen, Michiel P.C., E-mail: m.siroen6@upcmail.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Poll, Marcel C.G. van de, E-mail: mcg.vandepoll@ah.unimaas.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Boelens, Petra G., E-mail: p.boelens@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Dejong, Cornelis H.C., E-mail: chc.dejong@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Schaik, Cors van, E-mail: c.vanschaik@vumc.nl [Department of Radiology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Hofman, Mark B.M., E-mail: mbm.hofman@vumc.nl [Department of Physics and Medical Technology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Leeuwen, Paul A.M. van, E-mail: pam.vleeuwen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands)

    2012-09-15

    Background: Quantification of abdominal blood flow is essential for a variety of gastrointestinal and hepatic topics such as liver transplantation or metabolic flux measurement, but those need to be performed during surgery. It is not clear whether Duplex Doppler Ultrasound during surgery or MRI before surgery is the tool to choose. Objective: To examine whether preoperative evaluation of abdominal blood flow using MRI could prove to be a useful and reliable alternative for the perioperative sonographic approach. Methods: In this study portal and renal venous flow and hepatic arterial flow were sequentially quantified by preoperative MRI, preoperative and perioperative Duplex Doppler Ultrasound (DDUS). 55 Patients scheduled for major abdominal surgery were studied and methods and settings were compared. Additionally, average patient population values were compared. Results: Mean (±SD) plasmaflow measured by perioperative DDUS, preoperative DDUS and MRI, respectively was 433 ± 200/423 ± 162/507 ± 96 ml/min (portal vein); 96 ± 70/74 ± 41/108 ± 91 ml/min (hepatic artery); 248 ± 139/201 ± 118/219 ± 69 ml/min (renal vein). No differences between the different settings of DDUS measurement were detected. Equality of mean was observed for all measurements. Bland Altman Plots showed widespread margins. Hepatic arterial flow measurements correlated with each other, but portal and renal venous flow correlations were absent. Conclusions: Surgery and method (DDUS vs. MRI) do not affect mean flow values. Individual comparison is restricted due to wide range in measurements. Since MRI proves to be more reliable with respect to inter-observer variability, we recommend using mean MRI results in experimental setups.

  18. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  19. The efficiency of microbial protein production from tropical forages and its measurement using spot samples of urine and CrEDTA clearance from the plasma

    International Nuclear Information System (INIS)

    King, A.; Poppi, D.P.; McLennan, S.R.

    1999-01-01

    The efficiency of microbial crude protein production (MCP) expressed as g MCP/kg digestible organic matter (DOM) was much lower (P 0.75 /d). The fractional disappearance rate of CrEDTA from the plasma was similar for cattle consuming either hay (1.26-1.54%/min). The glomerular filtration rate (GFR) estimated from urinary creatinine excretion was significantly different (289 L/d vs 793 L/d, P vs R respectively). The ratio of predicted allantoin clearance determined by reference to plasma volume and FDR of CrEDTA to the actual urinary excretion was 6.7 and 9.6 for R and P respectively. This difference meant that clearance of CrEDTA could not be used as a technique in association with plasma concentration of allantoin to estimate urinary excretion of allantoin. (author)

  20. A simple estimation of the renal plasma flow

    International Nuclear Information System (INIS)

    Shinpo, Takako

    1987-01-01

    The renal plasma flow was determined conventionally by the excretive ratio to urine using a 131 I-Hippuran renogram. In this report, we proposed the renal clearance, the product of the disappearance rate coefficient and the maximum counts of the bladder, for the simple quantitative value of renal plasma flow. The disappearance rate coefficient was calculated by approximating the exponential function of the initial slope from the disappearance curve of the heart. The renal clearances was compared with the renal plasma flow calculated by the conventional method. The results gave a high correlation coefficient of r = 0.91. The renal clearances can be calculated easily and it offers useful renogram information. (author)

  1. RENAL INVOLVEMENT IN SUBJECTS WITH PERIPHERAL ATHEROSCLEROSIS

    International Nuclear Information System (INIS)

    FAWZY, A.; IBRAHIM, S.

    2008-01-01

    Ischemic nephropathy is an important cause of renal failure.Sub-clinical renal function abnormalities may exist in patients with extra renal atherosclerosis and may precede the onset of overt ischemic nephropathy. To assess the impact of extrarenal atherosclerosis on the kidney, the study evaluated renal function in 50 subjects with differing degrees of peripheral atherosclerosis without manifest clinical or laboratory signs of ischemic nephropathy and renovascular hypertension.All laboratory testing including total LDL and HDL-cholesterol, triglycerides, ultrasonography with Doppler analysis for the localization of peripheral vascular disease (carotid and lower limb arteries), and non-invasive evaluation of renal function by radionuclide studies of renal plasma flow (MAG3 clearance) and glomerular filtration (DTPA clearance) were determined as well as smoking habit was recorded. By combining sonographic data on arterial tree stenosis (ATS), the subjects were grouped according to the atherosclerotic vascular damage (ATS involvement). The results showed no change in plasma creatinine while DTPA clearance was increased from 91.58±26.53 to 93.47±24.82 ml/min/1.73 m. MAG3 clearance was progressively declined with the severity of vascular damage from 244.86 ± 60.60 to 173.59±58.74 ml/min/1.73 m.Stepwise, multiple regression analysis indicated that MAG3 clearance was best explained by ATS involvement (standardized B coefficient -0.40; P< 0.001), smoking habit (-0.34;P=0.004) and serum LDL-cholesterol (-0.24; P<0.035).It could be concluded that the renal hemodynamic profile in atherosclerotic patients might constitute functional evidence of the silent phase of ischemic renal disease. The findings suggest that renal function should be carefully assessed in patients with extrarenal atherosclerosis, particularly in those with classic cardiovascular risk factors

  2. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  3. Influence of renal dysfunction on the accuracy of procalcitonin for the diagnosis of postoperative infection after vascular surgery.

    Science.gov (United States)

    Amour, Julien; Birenbaum, Aurélie; Langeron, Olivier; Le Manach, Yannick; Bertrand, Michèle; Coriat, Pierre; Riou, Bruno; Bernard, Maguy; Hausfater, Pierre

    2008-04-01

    Procalcitonin has been advocated as a specific biomarker for bacterial infection. We performed this study to determine whether accuracy of procalcitonin for diagnosis of postoperative bacterial infection is affected by renal function after aortic surgery. Single-center prospective study. University hospital. Two hundred seventy-six patients scheduled for elective major aortic surgery. Blood samples were taken before surgery and each day over the 5-day postoperative period, and measurement of serum procalcitonin was performed. Diagnosis of infection was performed by a blinded expert panel. Renal function was assessed using an estimate of creatinine clearance with the Cockcroft formulas. Renal dysfunction was defined as a creatinine clearance <50 mL x min(-1). Infection was diagnosed in 67 patients. Seventy five patients (27%) had postoperative renal dysfunction. Procalcitonin was significantly higher in infected patients, with a peak reached at the fourth postoperative day, but it was significantly higher in patients with impaired renal function in both control and infected patients. The optimal threshold of procalcitonin markedly differed in patients with renal dysfunction compared with patients without renal dysfunction (2.57 vs. 0.80 ng x mL(-1), p < .05). The diagnostic accuracy of procalcitonin significantly increased (0.74 vs. 0.70, p < .05) when the threshold of procalcitonin was adapted to the renal function. The elevation of procalcitonin occurred 2 days before the medical team was able to diagnose infection. Procalcitonin is a valuable marker of bacterial infections after major aortic surgery, but renal function is a major determinant of procalcitonin levels and thus different thresholds should be applied according to renal function impairment.

  4. Genetic variation underlying renal uric acid excretion in Hispanic children: the Viva La Familia Study.

    Science.gov (United States)

    Chittoor, Geetha; Haack, Karin; Mehta, Nitesh R; Laston, Sandra; Cole, Shelley A; Comuzzie, Anthony G; Butte, Nancy F; Voruganti, V Saroja

    2017-01-17

    Reduced renal excretion of uric acid plays a significant role in the development of hyperuricemia and gout in adults. Hyperuricemia has been associated with chronic kidney disease and cardiovascular disease in children and adults. There are limited genome-wide association studies associating genetic polymorphisms with renal urate excretion measures. Therefore, we investigated the genetic factors that influence the excretion of uric acid and related indices in 768 Hispanic children of the Viva La Familia Study. We performed a genome-wide association analysis for 24-h urinary excretion measures such as urinary uric acid/urinary creatinine ratio, uric acid clearance, fractional excretion of uric acid, and glomerular load of uric acid in SOLAR, while accounting for non-independence among family members. All renal urate excretion measures were significantly heritable (p uric acid clearance with a single nucleotide polymorphism (SNP) in zinc finger protein 446 (ZNF446) (rs2033711 (A/G), MAF: 0.30). The minor allele (G) was associated with increased uric acid clearance. Also, we found suggestive associations of uric acid clearance with SNPs in ZNF324, ZNF584, and ZNF132 (in a 72 kb region of 19q13; p <1 × 10 -6 , MAFs: 0.28-0.31). For the first time, we showed the importance of 19q13 region in the regulation of renal urate excretion in Hispanic children. Our findings indicate differences in inherent genetic architecture and shared environmental risk factors between our cohort and other pediatric and adult populations.

  5. Nuclear medical investigations of renal transplants in dogs

    International Nuclear Information System (INIS)

    Chocholka, T.G.K.

    1981-01-01

    Within the frame of this study it was investigated if it is possible - by means of nuclear medicine - to assess transplant function after xenogenic (heterologic) renal transplantation, to early diagnose complications and to observe organ function in follow-up examinations. The examination comprised camera-function-scintiscanning (=CFS), i.e. camera-sequence-scintiscanning (=CSS) and radio-isotope-nephrography (=RING), and the clearance measurement, which were carried out in parallel, as one operation. The clearance measurement based on tissue activity decrease graphs, which were registered by means of a body probe. Hippuran iodine 131 was used as radiopharmaceutical which usually is eliminated by the kidneys. In 112 examinations 33 dogs, who had received a fox kidney transplant, were investigated, starting on the day of surgical intervention until the transplant dysfunction was confirmed. These dogs had been treated in advance with immunosuppressive agents: a control group of 8 dogs, who received renal transplants of dingos, were not treated with immunosuppressants. The CFS as simultaneous realisation of CSS and of RING and the clearance measurement by means of hippuran iodine 131 achieved the examination aims. CSS permitted a sufficient survey over the individual functional phases. RING allows the early diagnosis of complications due to transplantation. The nuclear medical findings of camera-functional-scintiscanning and of clearance measurement show correspondence and they correspond also well to those findings resulting from traditional examination techniques which were applied in parallel. This procedure distinguishes itself not only by the diagnostic liability of nuclear medical examination methods, but also by its uncomplicated application, which permits the careful treatment of the dogs. (orig./MG) [de

  6. Associations of Conventional Echocardiographic Measures with Incident Heart Failure and Mortality: The Chronic Renal Insufficiency Cohort

    Science.gov (United States)

    Deo, Rajat; Bansal, Nisha; Anderson, Amanda H.; Yang, Peter; Go, Alan S.; Keane, Martin; Townsend, Ray; Porter, Anna; Budoff, Matthew; Malik, Shaista; He, Jiang; Rahman, Mahboob; Wright, Jackson; Cappola, Thomas; Kallem, Radhakrishna; Roy, Jason; Sha, Daohang; Shlipak, Michael G.

    2017-01-01

    Background and objectives Heart failure is the most frequent cardiac complication of CKD. Left ventricular hypertrophy is common and develops early in CKD, but studies have not adequately evaluated the association of left ventricular mass index with heart failure incidence among men and women with CKD. Design, setting, participants, & measurements We evaluated echocardiograms of 2567 participants without self–reported heart failure enrolled in the Chronic Renal Insufficiency Cohort Study. Two-dimensional echocardiograms were performed at the year 1 study visit and interpreted at a central core laboratory. Left ventricular mass index was calculated using the linear method, indexed to height2.7, and analyzed using sex-specific quartiles. The primary outcomes of incident heart failure and all-cause mortality were adjudicated over a median of 6.6 (interquartile range, 5.7–7.6) years. Results Among 2567 participants, 45% were women, and 54% were nonwhite race; mean (SD) age was 59±11 years old, and mean eGFR was 44±17 ml/min per 1.73 m2. During a median follow-up period of 6.6 years, 262 participants developed heart failure, and 470 participants died. Compared with participants in the first quartile of left ventricular mass index, those in the highest quartile had higher rates of incident heart failure (hazard ratio, 3.96; 95% confidence interval, 1.96 to 8.02) and mortality (hazard ratio, 1.86; 95% confidence interval, 1.22 to 2.85), even after adjustment for B–type natriuretic peptide, troponin T, mineral metabolism markers, and other cardiovascular disease risk factors. Those in the lowest quartile of ejection fraction had higher rates of incident heart failure (hazard ratio, 3.01; 95% confidence interval, 1.94 to 4.67) but similar mortality rates (hazard ratio, 1.18; 95% confidence interval, 0.89 to 1.57) compared with those in the highest quartile. Diastolic dysfunction was not significantly associated with heart failure or death. Conclusions Among persons

  7. Improving the measurement of longitudinal change in renal function: automated detection of changes in laboratory creatinine assay

    Directory of Open Access Journals (Sweden)

    Norman Poh

    2015-04-01

    Full Text Available IntroductionRenal function is reported using the estimates of glomerular filtration rate (eGFR. However, eGFR values are recorded without reference to the particular serum creatinine (SCr assays used to derive them, and newer assays were introduced at different time points across the laboratories in the United Kingdom. These changes may cause systematic bias in eGFR reported in routinely collected data, even though laboratory-reported eGFR values have a correction factor applied.DesignAn algorithm to detect changes in SCr that in turn affect eGFR calculation method was developed. It compares the mapping of SCr values on to eGFR values across a time series of paired eGFR and SCr measurements.SettingRoutinely collected primary care data from 20,000 people with the richest renal function data from the quality improvement in chronic kidney disease trial.ResultsThe algorithm identified a change in eGFR calculation method in 114 (90% of the 127 included practices. This change was identified in 4736 (23.7% patient time series analysed. This change in calibration method was found to cause a significant step change in the reported eGFR values, producing a systematic bias. The eGFR values could not be recalibrated by applying the Modification of Diet in Renal Disease equation to the laboratory reported SCr values.ConclusionsThis algorithm can identify laboratory changes in eGFR calculation methods and changes in SCr assay. Failure to account for these changes may misconstrue renal function changes over time. Researchers using routine eGFR data should account for these effects.  

  8. Comparing the difference of measured GFR of ectopic pelvic kidney between anterior and posterior imaging processing in renal dynamic imaging

    International Nuclear Information System (INIS)

    Li Baojun; Zhao Deshan

    2014-01-01

    Objective: To compare and analyze the difference of measured glomerular filtration rate (GFR) of ectopic pelvic kidney between anterior and posterior imaging processing in renal dynamic imaging. Methods: There were 10 patients collected retrospectively, with ectopic kidneys in pelvic cavity confirmed by ultrasound, CT, renal dynamic imaging and other imaging modalities. All images of ectopic kidneys in renal dynamic imaging were processed by anterior and posterior methods respectively. The ectopic kidney was only processed in anterior imaging, ectopic kidney and contralateral normal kidney were processed in posterior imaging. Total GFR equalled the sum of GFR of normal kidney in posterior imaging and GFR of ectopic kidney in anterior imaging, was compared with total GFR of two kidneys in posterior imaging and GFR in two-sample method. All correlation analysis were completed between GFRs from three methods and all patients were followed up. Statistically paired t-test and bivariate correlation analysis test were used. Results: The mean GFR of ectopic kidney in anterior imaging equal to (27.48±12.24) ml/(min · 1.73 m 2 ). It was more than GFR [(10.71 ±4.74) ml/ (min · 1.73 m 2 )] in posterior imaging above 46% (t=5.481, P<0.01). There was no significant difference (t=-2.238, P>0.05), but better correlation (r=0.704, P<0.05) between total GFR in anterior imaging and GFR in two-sample method. There was significant difference (t=4.629, P<0.01)and worse correlation (r=0.576, P>0.05) between total GFR in posterior imaging and GFR in two-sample method. Conclusion: Comparing with GFR in posterior imaging, GFR in anterior imaging can more truly reflect function condition of ectopic pelvic kidney in renal dynamic imaging. (authors)

  9. The influence of partial renal function impairment on thyroid hormones level in acute renal failure-ARF patients

    International Nuclear Information System (INIS)

    Ilic, S.; Vlajkovic, M.; Rajic, M.; Bogicevic, M.

    2002-01-01

    The aim of this study was to assess the relationship of thyroid hormone levels with glomerular and tubular renal function in ARF. In thirty one patients with different underlying diseases, glomerular filtration (GFR) was estimated by measuring 99mTc-DTPA clearance and tubular function by 131I-OIH clearance. The thyroid status was evaluated by radioimmunoassays of T4, FT4, T3, FT3, rT3 and TSH, while the cortisol level was used to indicate the stress role. All the measurements were performed within 7 days as well after 1,3,6 and 12 months from the ARF onset. The results obtained were compared with those of 30 healthy subjects. At the ARF beginning, the impairment of renal function was manifested by the fall of 99mTc-DTPA clearance to 21∫7ml/min and 131I-OIH clearance to 172±34ml/min, while end values were 77±19ml/min and 395±70ml/min, respectively. The hormone analysis within 7 days, showed T3 decrease to 1.21±0.16nmol/l and the increase rT3 to 38±7ng/1ooml, as well as cortisol to 350±71ng/ml, but at the end of the study these hormone levels were normalized. Other hormone levels didn't differ significantly from control values. Regression analysis established significant correlation of 99mTc-DTPA clearance with T3 (r=0.693, p 100, OIH>500), partial recovery (DTPA 51-100, OIH 250-500) and without any recovery (DTPA<50,OIH<250), showed hormone disturbances proportional to the degree of renal function damage. The most severe disorders were found in the third group, where both total and free T4 and T3 were lowered, while rT3 and cortisol elevated at 7th day from ARF onset. After 12 months all these values associated with that of TSH were observed as declined.This study suggests thyroid hormone levels to be dependent on the renal function in ARF. Greater impairment of glomerular related to tubular function appears to be more responsible for thyroid dysfunction, due to uremic toxins retention as well as stress induced by the extreme function failure

  10. Renal effects of chronic exposure to organic solvents. A clinical controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Krusell, L.; Nielsen, H.K.; Baelum, J.; Lundqvist, G.; Omland, O.; Vaeth, M.; Husted, S.E.; Mogensen, C.E.; Geday, E.

    1985-01-01

    Chronic effects of organic solvents on renal function were measured by creatinine clearances and urinary excretion rates of beta 2-microglobulin and albumin. Forty-three male printing trade workers occupationally exposed to different organic solvents for 9-25 years were compared with 43 age-matched male controls. No differences were found either in creatinine clearances or average basal levels of beta 2-microglobulin and albumin excretion rates, whereas a positive relation could be demonstrated between alcohol consumption on the day before the trial and urinary excretion rate of albumin. This investigation did not reveal any adverse renal effects of moderate chronic exposure to organic solvents in a group of active trade workers.

  11. Renal effects of chronic exposure to organic solvents. A clinical controlled trial

    DEFF Research Database (Denmark)

    Krusell, Lars Romer; Nielsen, H K; Bælum, Jesper

    1985-01-01

    Chronic effects of organic solvents on renal function were measured by creatinine clearances and urinary excretion rates of beta 2-microglobulin and albumin. Forty-three male printing trade workers occupationally exposed to different organic solvents for 9-25 years were compared with 43 age......-matched male controls. No differences were found either in creatinine clearances or average basal levels of beta 2-microglobulin and albumin excretion rates, whereas a positive relation could be demonstrated between alcohol consumption on the day before the trial and urinary excretion rate of albumin....... This investigation did not reveal any adverse renal effects of moderate chronic exposure to organic solvents in a group of active trade workers....

  12. Behavioral measures to reduce non-adherence in renal transplant recipients: a prospective randomized controlled trial.

    Science.gov (United States)

    Garcia, Márcia Fátima Faraldo Martinez; Bravin, Ariane Moyses; Garcia, Paula Dalsoglio; Contti, Mariana Moraes; Nga, Hong Si; Takase, Henrique Mochida; de Andrade, Luis Gustavo Modelli

    2015-11-01

    Solid-organ transplant recipients present a high rate of non-adherence to drug treatment. Few interventional studies have included approaches aimed at increasing adherence. The objective of this study was to evaluate the impact of an educational and behavioral strategy on treatment adherence of kidney transplant recipients. In a randomized prospective study, incident renal transplant patients (n = 111) were divided into two groups: control group (received usual transplant patient education) and treatment group (usual transplant patient education plus ten additional weekly 30-min education/counseling sessions about immunosuppressive drugs and behavioral changes). Treatment adherence was assessed using ITAS adherence questionnaire after 3 months. Renal function at 3, 6, and 12 months, and the incidence of transplant rejection were evaluated. The non-adherence rates were 46.4 and 14.5 % in the control and treatment groups (p = 0.001), respectively. The relative risk for non-adherence was 2.59 times (CI 1.38-4.88) higher in the control group. Multivariate analysis demonstrated a 5.84 times (CI 1.8-18.8, p = 0.003) higher risk of non-adherence in the control group. There were no differences in renal function and rejection rates between groups. A behavioral and educational strategy addressing the patient's perceptions and knowledge about the anti-rejection drugs significantly improved the short-term adherence to immunosuppressive therapy.

  13. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  14. Aging aggravates long-term renal ischemia-reperfusion injury in a rat model.

    Science.gov (United States)

    Xu, Xianlin; Fan, Min; He, Xiaozhou; Liu, Jipu; Qin, Jiandi; Ye, Jianan

    2014-03-01

    Ischemia-reperfusion injury (IRI) has been considered as the major cause of acute kidney injury and can result in poor long-term graft function. Functional recovery after IRI is impaired in the elderly. In the present study, we aimed to compare kidney morphology, function, oxidative stress, inflammation, and development of renal fibrosis in young and aged rats after renal IRI. Rat models of warm renal IRI were established by clamping left pedicles for 45 min after right nephrectomy, then the clamp was removed, and kidneys were reperfused for up to 12 wk. Biochemical and histologic renal damage were assessed at 12 wk after reperfusion. The immunohistochemical staining of monocyte macrophage antigen-1 (ED-1) and transforming growth factor beta 1 (TGF-β1) and messenger RNA level of TGF-β1 in the kidney were analyzed. Renal IRI caused significant increases of malondialdehyde and 8-hydroxydeoxyguanosine levels and a decrease of superoxide dismutase activity in young and aged IRI rats; however, these changes were more obvious in the aged rats. IRI resulted in severe inflammation and tubulointerstitial fibrosis with decreased creatinine (Cr) clearance and increased histologic damage in aged rats compared with young rats. Moreover, we measured the ratio of Cr clearance between young and aged IRI rats. It demonstrated that aged IRI rats did have poor Cr clearance compared with the young IRI rats. ED-1 and TGF-β1 expression levels in the kidney were significantly higher in aged rats than in young rats after IRI. Aged rats are more susceptible to IRI-induced renal failure, which may associate with the increased oxidative stress, increased histologic damage, and increased inflammation and tubulointerstitial fibrosis. Targeting oxidative stress and inflammatory response should improve the kidney recovery after IRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting

    International Nuclear Information System (INIS)

    Ledermann, H.P.; Mengiardi, B.; Schmid, A.; Froehlich, J.M.

    2010-01-01

    To report the results and implications for workflow following introduction of ESUR guidelines to screen for potential renal insufficiency (RI) in private practice with on-site creatinine measurements. A total of 1,766 consecutive outpatients scheduled for contrast-enhanced CT (CECT) completed the ESUR questionnaire enquiring about kidney disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout or use of nephrotoxic drugs. Patients with positive risk factors underwent on-site creatinine measurement and calculation of estimated glomerular filtration rate (eGFR). Attending radiologists adapted subsequent imaging depending on renal function and presence of risk factors. One or more ESUR risk factors were present in 796 (45.1%) patients, including hypertension (37.7%), nephrotoxic medication (21.3%), diabetes mellitus (8.0%), proteinuria (3.9%), renal disease (4.1%), gout (3.1%) and renal surgery (2.6%). Pre-procedural creatinine measurements revealed severe RI (eGFR -1 1.73 m -2 ) in 10 (1.3%) and moderate RI (eGFR 30-59 ml min -1 1.73 m -2 ) in 106 (13.8%). Imaging work-up was adapted in 132 (16.6%) as follows: reduction of contrast material dose (n = 85), CT without contrast (n = 40), changeover to MRI (n = 3) or scintigraphy (n = 4). Screening for RI following ESUR guidelines requires creatinine measurements in nearly half of outpatients scheduled for CECT and reveals moderate to severe renal impairment in 6.6%. (orig.)

  16. Recombinant erythropoietin acutely decreases renal perfusion and decouples the renin-angiotensin-aldosterone system.

    Science.gov (United States)

    Aachmann-Andersen, Niels J; Christensen, Soren J; Lisbjerg, Kristian; Oturai, Peter; Johansson, Pär I; Holstein-Rathlou, Niels-Henrik; Olsen, Niels V

    2018-03-01

    The effect of recombinant erythropoietin (rhEPO) on renal and systemic hemodynamics was evaluated in a randomized double-blinded, cross-over study. Sixteen healthy subjects were tested with placebo, or low-dose rhEPO for 2 weeks, or high-dose rhEPO for 3 days. Subjects refrained from excessive salt intake, according to instructions from a dietitian. Renal clearance studies were done for measurements of renal plasma flow, glomerular filtration rate (GFR) and the segmentel tubular handling of sodium and water (lithium clearance). rhEPO increased arterial blood pressure, total peripheral resistance, and renal vascular resistance, and decreased renal plasma flow in the high-dose rhEPO intervention and tended to decrease GFR. In spite of the decrease in renal perfusion, rhEPO tended to decrease reabsorption of sodium and water in the proximal tubule and induced a prompt decrease in circulating levels of renin and aldosterone, independent of changes in red blood cell mass, blood volumes, and blood pressure. We also found changes in biomarkers showing evidence that rhEPO induced a prothrombotic state. Our results suggest that rhEPO causes a direct downregulation in proximal tubular reabsorption that seems to decouple the activity of the renin-angiotensin-aldosterone system from changes in renal hemodynamics. This may serve as a negative feed-back mechanism on endogenous synthesis of EPO when circulating levels of EPO are high. These results demonstrates for the first time in humans a direct effect of rhEPO on renal hemodynamics and a decoupling of the renin-angiotensin-aldosterone system. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  17. Prognosis for recovery of function in acute renal failure

    International Nuclear Information System (INIS)

    Harwood, T.H. Jr.; Hiesterman, D.R.; Robinson, R.G.; Cross, D.E.; Whittier, F.C.; Diederich, D.A.; Grantham, J.J.

    1976-01-01

    Twenty-four survivors of acute, nonobstructive, nonnephritic renal failure had a renal scan using iodohippurate sodium I 131 performed early in the acute illness. Scans were judged according to whether the renal images were prominent, faint, or absent during the first 30 minutes after intravenous injection of 100 to 250 microcuries of iodohippurate sodium I 131. All ten patients with prominent renal images attained life-sustaining renal function with an average postrecovery creatinine clearance of 80 ml/min. Of the seven patients with faint renal images, six recovered life-sustaining renal function (average creatinine clearance of 39 ml/min), and one required chronic hemodialysis. Seven patients had no renal image initially; four recovered life-sustaining renal function with an average creatinine clearance of 25 ml/min; three required chronic hemodialysis. We conclude that, for patients with acute renal failure, the appearance of the renal image obtained using this substance is an important indicator of renal viability and of the likelihood for functional recovery

  18. Role of calculated glomerular filtration rate using percutaneous nephrostomy creatinine clearance in the era of radionuclide scintigraphy

    Directory of Open Access Journals (Sweden)

    Sunil Raghunath Patil

    2017-01-01

    Conclusions: GFR based on radionuclide scintigraphy may be insufficient for evaluation of residual renal function to determine the management of obstructed kidney with borderline function. For adequate decision-making, other factors including creatinine clearance via PCN should also be considered. Gates method tends to overestimate GFR as compared to calculated creatinine clearance at low GFR levels.

  19. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention

    DEFF Research Database (Denmark)

    Henriksen, Ulrik L; Henriksen, Jens H

    2014-01-01

    In subjects without fluid retention, the total plasma clearance of a renal filtration indicator (inulin, (99m) Tc-DTPA, (51) Cr-EDTA) is close to the urinary plasma clearance. Conversely, in patients with fluid retention (oedema, pleural effusions, ascites), there is a substantial discrepancy...

  20. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  1. Anatomical and physiological basis for the allometric scaling of cisplatin clearance in dogs.

    Science.gov (United States)

    Achanta, S; Sewell, A; Ritchey, J W; Broaddus, K; Bourne, D W A; Clarke, C R; Maxwell, L K

    2016-06-01

    Cisplatin is a platinum-containing cytotoxic drug indicated for the treatment of solid tumors in veterinary and human patients. Several of the algorithms used to standardize the doses of cytotoxic drugs utilize allometry, or the nonproportional relationships between anatomical and physiological variables, but the underlying basis for these relationships is poorly understood. The objective of this proof of concept study was to determine whether allometric equations explain the relationships between body weight, kidney weight, renal physiology, and clearance of a model, renally cleared anticancer agent in dogs. Postmortem body, kidney, and heart weights were collected from 364 dogs (127 juveniles and 237 adults, including 51 dogs ≥ 8 years of age). Renal physiological and cisplatin pharmacokinetic studies were conducted in ten intact male dogs including two juvenile and eight adult dogs (4-55 kg). Glomerular filtration rate (GFR), effective renal plasma flow, effective renal blood flow, renal cisplatin clearance, and total cisplatin clearance were allometrically related to body weight with powers of 0.75, 0.59, 0.61, 0.71, and 0.70, respectively. The similar values of these diverse mass exponents suggest a common underlying basis for the allometry of kidney size, renal physiology, and renal drug handling. © 2015 John Wiley & Sons Ltd.

  2. Bromsulphalein (BSP) clearance in ageing rats

    NARCIS (Netherlands)

    Hollander, C.F.; Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.

    1968-01-01

    Liver function in ageing rats was studied, using the bromsulphalein (BSP) clearance test. The test was done on ultramicro scale. This made it possible to repeat the test several times in the same animal and to start a longitudinal study. In 3-month-old rats the BSP retentions, measured 15, 30 and 45

  3. Effects of positive end-expiratory pressure on renal function.

    Science.gov (United States)

    Järnberg, P O; de Villota, E D; Eklund, J; Granberg, P O

    1978-01-01

    The effects were studied positive end-expiratory pressure (PEEP) on renal function in eight patients with acute respiratory failure, requiring mechanical ventilation. On application of PEEP + 10 cm H2O, central venous pressure increased, systolic blood pressure decreased, urine flow and PAH-clearance were reduced, while inulin clearance remained stable. There was a marked increase in fractional sodium reabsorption and a concurrent decrease in fractional osmolal excretion. Fractional free-water clearance and the ratio UOsm/POsm did change.

  4. Predictive factors of lower calyceal stone clearance after Extracorporeal Shockwave Lithotripsy (ESWL): a focus on the infundibulopelvic anatomy.

    Science.gov (United States)

    Ghoneim, Islam A; Ziada, Ali M; Elkatib, Seif Eldin

    2005-08-01

    Controversy exists as to whether ESWL is suitable for lower pole renal stones, given the dependent position of the lower calyces. This study aims to test the effect of lower pole anatomy, namely lower polar infundibulo-pelvic angle, infundibular length and width, on clearance of fragments after ESWL. We conducted a retrospective study of 205 renal units with single lower pole stones of not more than 25 mm in their greatest diameter that were treated by ESWL alone. Exclusion criteria included multiple stones, patients requiring stenting or percutaneous drainage for various reasons. Pretreatment IVU was used to measure lower polar dimensions. Post treatment ultrasonography and KUB were used to assess clearance of fragments. The right kidney was involved in 68% and the left in 42% of cases. Average number of sessions was 1.6 with an average 3277 shockwaves per session. 134 patients (65.3%) required one session, 41 requiring 2 sessions (20%), 18 requiring 3 sessions (8.7%), 6 requiring 4 sessions (2.9%) and 8 requiring 5 sessions (3.9%). Complete clearance was attained in 141 cases, while 64 cases had residual fragments, 20 were asymptomatic and required no further management. The lower pole infundibulo-pelvic angle (LIP-A) was the most significant factor in clearance (p value 0.00001). Infundibular length (IL) was also statistically significant (p value 0.039). Lower pole anatomy has a significant impact on ESWL results. LIP-A not less than 70 degrees and an infundibular length of < 50 mm is preferable to achieve favorable outcome.

  5. Comparison of the Availability and Cost of Foods Compatible With a Renal Diet Versus an Unrestricted Diet Using the Nutrition Environment Measures Survey.

    Science.gov (United States)

    Sullivan, Catherine M; Pencak, Julie A; Freedman, Darcy A; Huml, Anne M; León, Janeen B; Nemcek, Jeanette; Theurer, Jacqueline; Sehgal, Ashwini R

    2017-05-01

    Hemodialysis patients' ability to access food that is both compatible with a renal diet and affordable is affected by the local food environment. Comparisons of the availability and cost of food items suitable for the renal diet versus a typical unrestricted diet were completed using the standard Nutrition Environment Measures Survey and a renal diet-modified Nutrition Environment Measures Survey. Cross-sectional study. Twelve grocery stores in Northeast Ohio. Availability and cost of food items in 12 categories. The mean total number of food items available differed significantly (P ≤ .001) between the unrestricted diet (38.9 ± 4.5) and renal diet (32.2 ± 4.7). The mean total cost per serving did not differ significantly (P = 0.48) between the unrestricted diet ($5.67 ± 2.50) and renal diet ($5.76 ± 2.74). The availability of renal diet food items is significantly less than that of unrestricted diet food items, but there is no difference in the cost of items that are available in grocery stores. Further work is needed to determine how to improve the food environment for patients with chronic diseases. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  6. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Hales, Patrick W.; Clark, Christopher A.; Gordon, Isky [UCL Institute of Child Health, Imaging and Biophysics Unit, London (United Kingdom); Thomas, David L. [UCL Institute of Neurology, Department of Brain Repair and Rehabilitation, London (United Kingdom); Banks, T. [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom)

    2014-06-15

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min{sup -1} [100 ml tissue]{sup -1}, and using DCE MRI was 287 ± 70 ml min{sup -1} [100 ml tissue]{sup -1}. The group coefficient of variation (CV{sub g}) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CV{sub g}s of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. (orig.)

  7. [Value of fractional flow reserve measurement in endovascular therapy for patients with Stanford B type aortic dissection complicated with renal blood flow injury].

    Science.gov (United States)

    Guo, Xi; Li, Peng; Liu, Guangrui; Huang, Xiaoyong; Yong, Qiang; Wang, Guoqin; Huang, Lianjun

    2015-10-01

    To analyze the value of fractional flow reserve (FFR) measurement on endovascular therapy for patients with renal artery stenosis. Clinical data of 12 patients with Stanford B type aortic dissection complicated with renal blood flow injury in Anzhen hospital hospitalized from May 2013 to February 2014 were retrospectively analyzed. Renal artery angiography was performed and fractional flow reserve (FFR) was measured before Thoracic endovascular aortic repair. After operation, renal artery FFR was measured again, and renal artery stenting was performed in patients with FFR ≤ 0.90 or average pressure difference between proximal and distal of renal artery > 20 mmHg (1 mmHg = 0.133 kPa) and not applied for patients with FFR > 0.90.The patients were then subsequently followed up clinically. Kidney function were measured after 1 month, and contrast-enhanced ultrasonography data were obtained at 1 and 3 months later, respectively. The FFR of 1 patient was 0.90, while the FFR of other patients were less than 0.90 before thoracic endovascular aortic repair. After the procedure,the angiography showed that the blood flow of renal artery in 8 patients were fluency, and the FFR index was over 0.90. There were 4 patients with FFR less than 0.90. After renal artery stenting, the FFR of these 4 patients were all above 0.90. Compared with pre-procedure, blood urea nitrogen ((8.84 ± 3.99) mmol/L vs. (5.18 ± 1.69) mmol/L, P = 0.011) and uric acid ((359.3 ± 77.3) µmol/L vs. (276.9 ± 108.3) µmol/L, P = 0.008) decreased significantly after 1 month, and there was no significant difference in serum creatinine (P = 0.760). Contrast-enhanced ultrasonography results showed that blood flow of renal artery were fluency after 1 month and 3 months. In patients with aortic dissection complicating renal blood flow injury, the FFR measurement is meaningful in evaluating the blood flow status of target organs and guide the endovascular revascularization.

  8. Improvement in Creatinine Clearance after Open Heart Surgery in Infants as an Early Indicator of Surgical Success.

    Science.gov (United States)

    Dagan, Amit; Dagan, Ovadia

    2016-12-01

    Early surgical correction of congenital heart malformations in neonates and small infants may be complicated by acute kidney injury (AKI), which is associated with higher morbidity and mortality rates, especially in patients who require dialysis. Glomerular filtration rate (GFR) is considered the best measurement of renal function which, in neonates and infants, is highly dependent on heart function. To determine whether measurements of creatinine clearance after open heart surgery in neonates and young infants can serve as an early indicator of surgical success or AKI. We conducted a prospective observational study in 19 neonates and small infants (body weight creatinine clearance and albumin excretion was performed before and during surgery and four times during 48 hours after surgery. Mean creatinine clearance was lowest during surgery (25.2 ± 4. ml/min/1.73 m2) and increased significantly in the first 16 hours post-surgery (45.7 ± 6.3 ml/min/1.73 m2). A similar pattern was noted for urine albumin which was highest during surgery (203 ± 31 µg/min) and lowest (93 ± 20 µg/min) 48 hours post-surgery. AKI occurred in four patients, and two patients even required dialysis. All six showed a decline in creatinine clearance and an increase in urine albumin between 8 and 16 hours post-surgery. In neonates and small infants undergoing open heart surgery, a significant improvement in creatinine clearance in the first 16 hours postoperatively is indicative of a good surgical outcome. This finding has important implications for the early evaluation and treatment of patients in the intensive care unit on the first day post-surgery.

  9. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J. [Abteilung Nephrologie, Medizinische Hochschule Hannover (Germany); Hoogestraat-Lufft, Linda; Galanski, Michael [Abteilung Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany)

    2002-04-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, {mu}mol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, {mu}g/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174{+-}65 and 104{+-}56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean{+-}SD) did not change significantly (before DSA: 171{+-}158 and 61{+-}24, after DSA: 189{+-}177 and 61{+-}25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134{+-}109 to 141{+-}113 (p<0.01), In-Cl dropped from 65{+-}26 to 62{+-}26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 {mu}mol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest

  10. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    International Nuclear Information System (INIS)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J.; Hoogestraat-Lufft, Linda; Galanski, Michael

    2002-01-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, μmol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, μg/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174±65 and 104±56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean±SD) did not change significantly (before DSA: 171±158 and 61±24, after DSA: 189±177 and 61±25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134±109 to 141±113 (p<0.01), In-Cl dropped from 65±26 to 62±26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 μmol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest that AP performed for RAS has

  11. Comparative study of three methods of estimation of creatinine clearance in critically ill patients.

    Science.gov (United States)

    Blasco, V; Antonini, F; Zieleskiewicz, L; Hammad, E; Albanèse, J; Martin, C; Leone, M

    2014-05-01

    At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU). Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis. Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05). Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  12. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    International Nuclear Information System (INIS)

    Kamper, A.L.; Thomsen, H.S.; Nielsen, S.L.; Strandgaard, S.; Herlev Hospital

    1990-01-01

    Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51 Cr-EDTA plasma clearance fell by 14% (P 99m Tc-DMSA increased by 10% (P<0.01). It is concluded that DMSA in chronic renal failure is mainly taken up by the tubular cells from the peritubular capillaries since the uptake was unaffected by the acute decrease in GFR. (orig.)

  13. Renal function after prolonged hypotensive anesthesia and surgery in dogs with reduced renal mass.

    Science.gov (United States)

    Stone, E A; Rawlings, C A; Finco, D R; Crowell, W A

    1981-10-01

    The effect of prolonged hypotensive anesthesia and surgery on renal function was studied in 8 dogs with decreased renal mass. Renal mass was reduced by unilateral nephrectomy and ligation of 4 of the 6 terminal renal artery branches of the opposite kidney. One week after reduction in renal mass, the dogs were azotemic with a serum urea nitrogen (SUN) value of 65.8 +/- 11.5 mg/dl. Glomerular filtration rate, as estimated by 14C-inulin clearance, was 0.66 +/- 0.19 ml/kg of body weight/hour. A mean arterial pressure of less than 75 mm of Hg was maintained for 4 hours in dogs given 2.3 +/- 0.7% halothane. An exploratory laparotomy lasting 1 hour was performed. The day after the hypotensive episode, 3 dogs began vomiting, became dehydrated, and had SUN values greater than 100 mg/dl. The SUN values returned to base-line values after the dogs were rehydrated. Eight days after the hypotensive episode, 14C-inulin clearance decreased 15.2 +/- 8.2% (P less than 0.005) compared with base-line clearance values. Light microscopic and electron microscopic observations of the kidneys did not demonstrate acute renal failure. Prolonged hypotensive anesthesia can cause a decrease in renal function, and may cause prerenal uremia and/or acute renal failure.

  14. Influence of renal function on the elimination of morphine and morphine glucuronides

    DEFF Research Database (Denmark)

    Wolff, Jesper; Bigler, Dennis Richard; Christensen, C B

    1988-01-01

    plasma. No significant correlation was found between total body clearance of unconjugated morphine and 51Cr-EDTA clearance. However, patients with renal insufficiency had impaired elimination of morphine glucuronides, and the apparent clearance was significantly correlated with the 51Cr-EDTA clearance (r...... = 0.94, p less than 0.001). A relatively long terminal elimination of half-life of morphine was found in all patients (mean +/- SD: 9.2 +/- 2.5 h), irrespective of glomerular function....

  15. Creatinine Clearance and Estimated Glomerular Filtration Rate – When are they Interchangeable

    OpenAIRE

    Šimetić, Lucija; Zibar, Lada; Drmić, Sandra; Begić, Ivana; Šerić, Vatroslav

    2015-01-01

    Study goal was to examine which of glomerular rate equations is most suitable for prediction of creatinine clearance. Using a retrospective review of data from 500 hospital patients we calculated glomerular filtration rate according to Cockcroft-Gault equation (C-G), Modification of Diet in Renal Disease Study equation (MDRD) and Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI). We determined if results of these equations were compatible with creatinine clearance, and does...

  16. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  17. Clinical benefits of using inulin clearance and cystatin C for determining glomerular filtration rate in HIV-1-infected individuals treated with dolutegravir.

    Science.gov (United States)

    Yukawa, Satomi; Watanabe, Dai; Uehira, Tomoko; Shirasaka, Takuma

    2018-03-01

    Dolutegravir may inhibit creatinine transporters in renal tubules and elevate serum creatinine levels. We investigated the usefulness of glomerular filtration rate (GFR) measured using inulin clearance (Cin), creatinine clearance (Ccr), and estimated GFR based on both serum creatinine (eGFRcre) and serum cystatin C (eGFRcys). HIV-1-infected Japanese patients with suppressed viremia and whose antiretroviral drug was switched to dolutegravir from other drugs were included (n = 108, Study 1). We compared eGFRcre and eGFRcys at the start and after 48 weeks of dolutegravir administration. For the patients providing consent, we measured Cin and Ccr (n = 15, Study 2). We assessed biases and accuracy and compared Cin with eGFRcre, eGFRcys, and Ccr. There were no differences in serum cystatin C and eGFRcys between baseline and at 48 weeks. Moreover, eGFRcre was significantly less accurate (within 30% of measured GFR) than both eGFRcys and Ccr (40% accuracy compared to 93% and 93%, respectively). eGFRcys was significantly less biased than eGFRcre and Ccr (p inulin clearance and eGFRcys. This is the first study performing inulin clearance for HIV-1-infected individuals and to show data for eGFRcys from a large cohort following a switch to dolutegravir from other antiretroviral agents. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Comparison of radioisotope methods for the measurement of phosphate absorption in normal subjects and in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Farrington, K.; Mohammed, M.N.; Newman, S.P.; Varghese, Z.; Moorhead, J.F.

    1981-01-01

    Intestinal phosphate absorption was measured in normal subjects, in patients with chronic renal failure, and in post-transplant patients, by a double isotope technique involving oral administration of 32 P and simultaneous intravenous injection of 33 P with subsequent deconvolution analysis. By this technique intestinal phosphate absorption has been shown to have two components: an initial rapid phase, which is completed by 3 h, and a slower more prolonged phase, which continues beyond 71/2 h. Phosphate malabsorption has been demonstrated in chronic renal failure and transplant patients, which is accounted for by impairment of the initial phase of absorption. Results obtained by deconvolution analysis have been compared with other estimates of phosphate absorption obtained from analysis of 32 P radioactivity curves alone. The fractional hourly rate of absorption and the plasma 32 P radioactivity at 60 min corrected for extracellular fluid volume provided the best approximations to the result obtained by deconvolution analysis, with respect to both the maximal rate of phosphate absorption and cumulative percentage phosphate absorption. (author)

  19. Homocystein and carotid atherosclerosis in chronic renal failure.

    Science.gov (United States)

    Lubomirova, M; Tzoncheva, A; Petrova, J; Kiperova, B

    2007-10-01

    Since total homocysteine (Hcy) is markedly elevated in patients with chronic renal failure (CRF), it has been presented as potential factor contributing to the high risk of cardiovascular disease (CVD) in CRF. The aim of the study was to examine the significance of elevated Hcy and other cardiovascular risk factors for carotid atherosclerosis in patients with CRF. Fifty six patients 16-M, 40-F, average age 58+/-14.55, creatinine clearance 39.19+/-10.11 ml/min were examined. In addition, 20 control healthy subjects were examined. The association of Hcy levels and classic risk factors for atherosclerosis with common carotid intima-media thickness (IMT) was examined. B-mode ultrasound measurement of carotid IMT was performed in 56 hypertensive pts with CRF (glomerular filtration rate>20 ml/min and 0.05). Significant predictors for IMT were age (r=0.358, p<0.04), duration of hypertension (r=0.395, p=0.023), diabetes duration (r=0.343, p<0.02), as well as duration of CRF (r=0.324, p<0.006). There was a negative correlation between IMT and glomerular filtration rate assessed by creatinine clearance (r=-0.303, p<0.003). Renal function, described by creatinine clearance was the strongest determinant for Hcy levels (r=-0.332, p<0.008). Increased IMT was estimated in pts with CRF compared to healthy controls (0.74+/-0.10 vs 0.59+/-0.10, p<0.001). We found association between Hcy and carotid IMT ( r=0.344, p<0.015). No consistent association was found between IMT and other specific for CRF cardiovascular risk factors. The study suggests that patients with mild renal failure have increased IMT of the common carotid artery and that elevated plasma Hcy level in CRF is associated with carotid intima- media thickening.

  20. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  1. Comparison of para-aminophenol cytotoxicity in rat renal epithelial cells and hepatocytes.

    Science.gov (United States)

    Li, Ying; Bentzley, Catherine M; Tarloff, Joan B

    2005-04-01

    Several chemicals, including para-aminophenol (PAP), produce kidney damage in the absence of hepatic damage. Selective nephrotoxicity may be related to the ability of the kidney to reabsorb filtered water, thereby raising the intraluminal concentration of toxicants and exposing tubular epithelial cells to higher concentrations than would be present in other tissues. The present experiments tested the hypothesis that hepatocytes and renal epithelial cells exposed to equivalent concentrations of PAP would be equally susceptible to toxicity. Hepatocytes and renal epithelial cells were prepared by collagenase digestion of tissues obtained from female Sprague-Dawley rats. Toxicity was monitored using trypan blue exclusion, oxygen consumption and ATP content. We measured the rate of PAP clearance and formation of PAP-glutathione conjugate by HPLC. We found that renal epithelial cells accumulated trypan blue and showed declines in oxygen consumption and ATP content at significantly lower concentrations of PAP and at earlier time points than hepatocytes. The half-life of PAP in hepatocyte incubations was significantly shorter (0.71+/-0.07 h) than in renal epithelial cell incubations (1.33+/-0.23 h), suggesting that renal epithelial cells were exposed to PAP for longer time periods than hepatocytes. Renal epithelial cells formed significantly less glutathione conjugates of PAP (PAP-SG) than did hepatocytes, consistent with less efficient detoxification of reactive PAP intermediates by renal epithelial cells. Finally, hepatocytes contained significant more reduced glutathione (NPSH) than did renal epithelial cells, possibly explaining the enhanced formation of PAP-SG by this cell population. In conclusion, our data indicates that renal epithelial cells are intrinsically more susceptible to PAP cytotoxicity than are hepatocytes. This enhanced cytotoxicity may be due to longer exposure to PAP and/or reduced detoxification of reactive intermediates due to lower concentrations

  2. Hypogonadism and renal failure: An update.

    Science.gov (United States)

    Thirumavalavan, Nannan; Wilken, Nathan A; Ramasamy, Ranjith

    2015-01-01

    The prevalence of both hypogonadism and renal failure is increasing. Hypogonadism in men with renal failure carries with it significant morbidity, including anemia and premature cardiovascular disease. It remains unclear whether testosterone therapy can affect the morbidity and mortality associated with renal failure. As such, in this review, we sought to evaluate the current literature addressing hypogonadism and testosterone replacement, specifically in men with renal failure. The articles chosen for this review were selected by performing a broad search using Pubmed, Embase and Scopus including the terms hypogonadism and renal failure from 1990 to the present. This review is based on both primary sources as well as review articles. Hypogonadism in renal failure has a multifactorial etiology, including co-morbid conditions such as diabetes, hypertension, old age and obesity. Renal failure can lead to decreased luteinizing hormone production and decreased prolactin clearance that could impair testosterone production. Given the increasing prevalence of hypogonadism and the potential morbidity associated with hypogonadism in men with renal failure, careful evaluation of serum testosterone would be valuable. Testosterone replacement therapy should be considered in men with symptomatic hypogonadism and renal failure, and may ameliorate some of the morbidity associated with renal failure. Patients with all stages of renal disease are at an increased risk of hypogonadism that could be associated with significant morbidity. Testosterone replacement therapy may reduce some of the morbidity of renal failure, although it carries risk.

  3. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  4. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp; Iguchi, Toshihiro, E-mail: i10476@yahoo.co.jp; Fujiwara, Hiroyasu, E-mail: hirofujiwar@gmail.com; Kawabata, Takahiro, E-mail: tkhr-kwbt@yahoo.co.jp [Okayama University Medical School, Department of Radiology (Japan); Yamauchi, Takatsugu, E-mail: me9248@hp.okayama-u.ac.jp; Yamaguchi, Takuya, E-mail: me8738@hp.okayama-u.ac.jp [Okayama University Hospital, Central Division of Radiology (Japan); Kanazawa, Susumu, E-mail: susumu@cc.okayama-u.ac.jp [Okayama University Medical School, Department of Radiology (Japan)

    2016-06-15

    IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  5. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.

    Science.gov (United States)

    Matsui, Yusuke; Hiraki, Takao; Gobara, Hideo; Iguchi, Toshihiro; Fujiwara, Hiroyasu; Kawabata, Takahiro; Yamauchi, Takatsugu; Yamaguchi, Takuya; Kanazawa, Susumu

    2016-06-01

    Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator's finger skin was measured using thermoluminescent dosimeter rings. The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator's finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  6. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  7. Euthyroid sick syndrome in patients with acute renal failure

    International Nuclear Information System (INIS)

    Ilic Slobodan; Vlajkovic Marina; Rajic Milena; Bogicevic Momcilo

    2004-01-01

    Objectives: The purpose of this study was to evaluate serum thyroid hormone profile in acute renal failure (ARF) patients according to the initial 131I-OIH clearance value as a predictor of ARF outcome. Patients and methods: Radioimmuno-assays of T4, T3, FT4, FT3, rT3 and TSH were performed in 32 ARF patients within 7 days and 6 months after ARF onset. The patients were divided into three groups according to the kidney function recovery potential measured by 131I-OIH clearance as follows: Group I: high probability for kidney recovery (131I-OIH clearance >250 ml/min), Group II: intermediate probability for kidney recovery (131I-OIH clearance 151-250 ml/min) and Group III: low probability for kidney recovery (131I-OIH clearance <150 ml/min). The results were compared with those obtained in 20 healthy patients. Results: Total thyroid hormone and TSH values are displayed in the table, Values of total T4 and TSH were slightly declined in the Group I but without reaching the statistical significance, while total T3 value was significantly decreased seven days after ARF onset. In the groups with intermediate and low probability for kidney recovery both T3 and T4 values were significantly dropped, being most prominent in the III group. After six months, the most severe fall of thyroid hormone levels without reaching the normalization was found only in the Group III while in the Group I and II normalization of total thyroid hormone levels was achieved. At the end of the observation period ARF patients with low probability for kidney recovery were found significantly lower values of TSH. Conclusion: Acute renal failure affects thyroid function leading to euthyroid sick syndrome characterized by declined serum T3 and T4 without TSH elevation. Thyroid hormone a disturbance is in accordance with the impairment of renal function being the most pronounced in patient with low probability for kidney recovery. This pattern of altered thyroid hormone levels could be a result of

  8. Stent revascularization restores cortical blood flow and reverses tissue hypoxia in atherosclerotic renal artery stenosis but fails to reverse inflammatory pathways or glomerular filtration rate.

    Science.gov (United States)

    Saad, Ahmed; Herrmann, Sandra M S; Crane, John; Glockner, James F; McKusick, Michael A; Misra, Sanjay; Eirin, Alfonso; Ebrahimi, Behzad; Lerman, Lilach O; Textor, Stephen C

    2013-08-01

    Atherosclerotic renal artery stenosis (ARAS) is known to reduce renal blood flow, glomerular filtration rate (GFR) and amplify kidney hypoxia, but the relationships between these factors and tubulointerstitial injury in the poststenotic kidney are poorly understood. The purpose of this study was to examine the effect of renal revascularization in ARAS on renal tissue hypoxia and renal injury. Inpatient studies were performed in patients with ARAS (n=17; >60% occlusion) before and 3 months after stent revascularization, or in patients with essential hypertension (n=32), during fixed Na(+) intake and angiotensin converting enzyme/angiotensin receptors blockers Rx. Single kidney cortical, medullary perfusion, and renal blood flow were measured using multidetector computed tomography, and GFR by iothalamate clearance. Tissue deoxyhemoglobin levels (R(2)*) were measured by blood oxygen level-dependent MRI at 3T, as was fractional kidney hypoxia (percentage of axial area with R(2)*>30/s). In addition, we measured renal vein levels of neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α. Pre-stent single kidney renal blood flow, perfusion, and GFR were reduced in the poststenotic kidney. Renal vein neutrophil gelatinase-associated lipocalin, tumor necrosis factor-α, monocyte chemoattractant protein-1, and fractional hypoxia were higher in untreated ARAS than in essential hypertension. After stent revascularization, fractional hypoxia fell (Pblood flow, whereas GFR and neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α remained unchanged. These data demonstrate that despite reversal of renal hypoxia and partial restoration of renal blood flow after revascularization, inflammatory cytokines and injury biomarkers remained elevated and GFR failed to recover in ARAS. Restoration of vessel patency alone failed to reverse tubulointerstitial damage and partly

  9. Outcome and renal function following salvage surgery for bilateral ...

    African Journals Online (AJOL)

    Objective: The aim of this study was to determine the surgical outcomes and renal function following salvage surgery for bilateral Wilms tumor (BWT). Summary background data The challenge for the surgeon treating BWT lies in striking a fine balance between renal preservation and oncological clearance. Methods: This is ...

  10. Renal Extraction and Acute Effects of Glucagon-like peptide-1 on Central and Renal Hemodynamics in Healthy Men

    DEFF Research Database (Denmark)

    Asmar, Ali; Simonsen, Lene; Asmar, Meena

    2015-01-01

    of either GLP-1 (1.5 pmol kg-1 min-1) or saline, cardiac output was estimated non-invasively, and intra-arterial blood pressure and heart rate were measured continuously. Renal plasma flow, glomerular filtration rate, and uptake/release of hormones and ions were measured by Fick's Principle after...... catheterization of a renal vein. The subjects remained supine during the experiments. During GLP-1 infusion, the systolic blood pressure and arterial pulse pressure both increased by 5 ± 1 mm Hg (p=0.015 and p=0.002, respectively). Heart rate increased by 5 ± 1 bpm (p=0.005) and cardiac output increased by 18...... % (p=0.016). Renal plasma flow and glomerular filtration rate as well as clearance of sodium and lithium were not affected by GLP-1. However, plasma renin activity decreased (p=0.037), whereas plasma levels of atrial natriuretic peptide (ANP) were unaffected. Renal extraction of intact GLP-1 was 43% (p...

  11. Quantitative renal cinescintigraphy with iodine-123 hippuran methodological aspects, kit for labeling of hippuran

    International Nuclear Information System (INIS)

    Mehdaoui, A.; Pecking, A.; Delorme, G.; Mathonnat, F.; Debaud, B.; Bardy, A.; Coornaert, S.; Merlin, L.; Vinot, J.M.; Desgrez, A.; Gambini, D.; Vernejoul, P. de.

    1981-08-01

    The development of an extemporaneous kit for the labeling of ortho-iodo-hippuric acid (Hippuran) with iodine 123 allows the performance of a routine quantitative renal cinescintigraphy providing in 20 minutes, and in an absolutely non-traumatic way, a very complete renal morphofunctional study including: a cortical renal scintigraphy, sequential scintigraphies of excretory tract, renal functional curves, tubular, global, and separate clearances for each kidney. This functional quantitative investigation method should take a preferential place in the routine renal balance. The methodology of the technique is explained and compared to classical methods for estimation of tubular, global and separate clearances [fr

  12. Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study.

    Science.gov (United States)

    Wah, Tze Min; Sourbron, Steven; Wilson, Daniel Jonathan; Magee, Derek; Gregory, Walter Martin; Selby, Peter John; Buckley, David L

    2018-01-08

    To investigate if the early treatment effects of radiofrequency ablation (RFA) on renal cell carcinoma (RCC) can be detected with dynamic contrast enhanced (DCE)-MRI and to correlate RCC perfusion with RFA treatment time. 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm). Perfusion of the RCCs decreased significantly ( p measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.

  13. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  14. Objective measures of renal mass anatomic complexity predict rates of major complications following partial nephrectomy.

    Science.gov (United States)

    Simhan, Jay; Smaldone, Marc C; Tsai, Kevin J; Canter, Daniel J; Li, Tianyu; Kutikov, Alexander; Viterbo, Rosalia; Chen, David Y T; Greenberg, Richard E; Uzzo, Robert G

    2011-10-01

    The association between tumor complexity and postoperative complications after partial nephrectomy (PN) has not been well characterized. We evaluated whether increasing renal tumor complexity, quantitated by nephrometry score (NS), is associated with increased complication rates following PN using the Clavien-Dindo classification system (CCS). We queried our prospectively maintained kidney cancer database for patients undergoing PN from 2007 to 2010 for whom NS was available. All patients underwent PN. Tumors were categorized into low- (NS: 4-6), moderate- (NS: 7-9), and high-complexity (NS: 10-12) lesions. Complication rates within 30 d were graded (CCS: I-5), stratified as minor (CCS: I or 2) or major (CCS: 3-5), and compared between groups. A total of 390 patients (mean age: 58.0 ± 11.9 yr; 66.9% male) undergoing PN (44.6% open, 55.4% robotic) for low- (28%), moderate- (55.6%), and high-complexity (16.4%) tumors (mean tumor size: 3.74 ± 2.4 cm; median: 3.2 cm) from 2007 to 2010 were identified. Tumor size, estimated blood loss, and ischemia time all significantly differed (prenal tumors. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  15. Assessment of split renal function with sup(99m)Tc-aprotinin

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, C.; Saponaro, R.; Villa, G.; Carena, M.; Lunghi, F.; Salvadeo, A.; Solerte, S.B.

    1986-05-01

    The aim of this work is to correlate the net kidney uptake of sup(99m)Tc-aprotinin (TcA) in 103 subjects with separate effective renal plasma flow (ERPF) and some blood chemistry parameters at 90, 180, and 360 min postinjection both in the normal and diseased kidney. Correlations found with separate ERPFs are highly significant at any time. However, although the slope of the regression line is steeper at 180 min, r tends to deteriorate slightly with time postinjection and a higher intercept of the y axis; this pattern is more pronounced if diseased kidneys are considered separately. The following are probably related to the renal handling of TcA: (1) Early scans better reflect blood flow to the kidney, while later scans are more related to the metabolism/-excretion tubular mechanisms; (2) correlations found with urea, creatinine, urea clearance, and creatinine clearance are highly significant at any time; (3) in 20 additional patients with diseased kidneys, renal uptake measurements done 360 min postinjection first with TcA and then with MSA showed better correlations with ERPF employing TcA. Our results indicate that TcA is a feasible indicator of split renal function even at 90 min postinjections when a scan is easily carried out on an outpatient basis.

  16. Assessment of split renal function with sup(99m)Tc-aprotinin

    International Nuclear Information System (INIS)

    Aprile, C.; Saponaro, R.; Villa, G.; Solerte, S.B.

    1986-01-01

    The aim of this work is to correlate the net kidney uptake of sup(99m)Tc-aprotinin (TcA) in 103 subjects with separate effective renal plasma flow (ERPF) and some blood chemistry parameters at 90, 180, and 360 min postinjection both in the normal and diseased kidney. Correlations found with separate ERPFs are highly significant at any time (P<0.001). However, although the slope of the regression line is steeper at 180 min, r tends to deteriorate slightly with time postinjection and a higher intercept of the y axis; this pattern is more pronounced if diseased kidneys are considered separately. The following are probably related to the renal handling of TcA: (1) Early scans better reflect blood flow to the kidney, while later scans are more related to the metabolism/-excretion tubular mechanisms; (2) correlations found with urea, creatinine, urea clearance, and creatinine clearance are highly significant at any time; (3) in 20 additional patients with diseased kidneys, renal uptake measurements done 360 min postinjection first with TcA and then with MSA showed better correlations with ERPF employing TcA. Our results indicate that TcA is a feasible indicator of split renal function even at 90 min postinjections when a scan is easily carried out on an outpatient basis. (orig.)

  17. Rosiglitazone Affects Nitric Oxide Synthases and Improves Renal Outcome in a Rat Model of Severe Ischemia/Reperfusion Injury

    Directory of Open Access Journals (Sweden)

    Boris Betz

    2012-01-01

    Full Text Available Background. Nitric oxide (NO-signal transduction plays an important role in renal ischemia/reperfusion (I/R injury. NO produced by endothelial NO-synthase (eNOS has protective functions whereas NO from inducible NO-synthase (iNOS induces impairment. Rosiglitazone (RGZ, a peroxisome proliferator-activated receptor (PPAR-γ agonist exerted beneficial effects after renal I/R injury, so we investigated whether this might be causally linked with NOS imbalance. Methods. RGZ (5 mg/kg was administered i.p. to SD-rats (f subjected to bilateral renal ischemia (60 min. Following 24 h of reperfusion, inulin- and PAH-clearance as well as PAH-net secretion were determined. Morphological alterations were graded by histopathological scoring. Plasma NOx-production was measured. eNOS and iNOS expression was analyzed by qPCR. Cleaved caspase 3 (CC3 was determined as an apoptosis indicator and ED1 as a marker of macrophage infiltration in renal tissue. Results. RGZ improves renal function after renal I/R injury (PAH-/inulin-clearance, PAH-net secretion and reduces histomorphological injury. Additionally, RGZ reduces NOx plasma levels, ED-1 positive cell infiltration and CC3 expression. iNOS-mRNA is reduced whereas eNOS-mRNA is increased by RGZ. Conclusion. RGZ has protective properties after severe renal I/R injury. Alterations of the NO pathway regarding eNOS and iNOS could be an explanation of the underlying mechanism of RGZ protection in renal I/R injury.

  18. Effect of metabolic regulation on renal leakiness to dextran molecules in short-term insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Parving, H H; Rutili, F; Granath, K

    1979-01-01

    Renal clearance of dextran of two ranges of molecular size and glomerular filtration rate (GFR, 51Cr-EDTA) were measured in seven short-term insulin-dependent diabetics (mean age 25 years). Measurements were carried out in the same patient during good and poor metabolic regulation (plasma glucose......, mean +/- SEM, 6.5 +/- 0.9 and 14.8 +/- 1.5 mmol/l, respectively). GFR was elevated in all patients during poor metabolic regulation (119 +/- 6 ml/min/1.73 m2, versus 99 +/- 2 ml/min/1.73 m2 during good control, p less than 0.01). The average renal clearance of dextran with molecular weights ranging...... from 25,000 to 35,000 and 35,000 to 45,000 increased during poor metabolic regulation from 14.8 +/- 0.8 to 19.8 +/- 1.8 ml/min/1.73 m2, and 5.2 +/- 0.3 to 6.8 +/- 0.6 ml/min/1.73 m2, respectively (p less than 0.05). The elevated GFR and renal dextran clearance found during poor metabolic regulation...

  19. Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting

    Energy Technology Data Exchange (ETDEWEB)

    Ledermann, H.P.; Mengiardi, B.; Schmid, A. [IMAMED Radiologie Nordwest, Basel (Switzerland); Froehlich, J.M. [Guerbet AG, Medical Affairs, Zurich (Switzerland); University of Bern, Radiology Department, Bern (Switzerland)

    2010-08-15

    To report the results and implications for workflow following introduction of ESUR guidelines to screen for potential renal insufficiency (RI) in private practice with on-site creatinine measurements. A total of 1,766 consecutive outpatients scheduled for contrast-enhanced CT (CECT) completed the ESUR questionnaire enquiring about kidney disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout or use of nephrotoxic drugs. Patients with positive risk factors underwent on-site creatinine measurement and calculation of estimated glomerular filtration rate (eGFR). Attending radiologists adapted subsequent imaging depending on renal function and presence of risk factors. One or more ESUR risk factors were present in 796 (45.1%) patients, including hypertension (37.7%), nephrotoxic medication (21.3%), diabetes mellitus (8.0%), proteinuria (3.9%), renal disease (4.1%), gout (3.1%) and renal surgery (2.6%). Pre-procedural creatinine measurements revealed severe RI (eGFR < 30 ml min{sup -1} 1.73 m{sup -2}) in 10 (1.3%) and moderate RI (eGFR 30-59 ml min{sup -1} 1.73 m{sup -2}) in 106 (13.8%). Imaging work-up was adapted in 132 (16.6%) as follows: reduction of contrast material dose (n = 85), CT without contrast (n = 40), changeover to MRI (n = 3) or scintigraphy (n = 4). Screening for RI following ESUR guidelines requires creatinine measurements in nearly half of outpatients scheduled for CECT and reveals moderate to severe renal impairment in 6.6%. (orig.)

  20. PGI2 synthesis and excretion in dog kidney: evidence for renal PG compartmentalization

    International Nuclear Information System (INIS)

    Boyd, R.M.; Nasjletti, A.; Heerdt, P.M.; Baer, P.G.

    1986-01-01

    To assess the concept of compartmentalization of renal prostaglandins (PG), we compared entry of PGE2 and the PGI2 metabolite 6-keto-PGF1 alpha into the renal vascular and tubular compartments, in sodium pentobarbital-anesthetized dogs. Renal arterial 6-keto-PGF1 alpha infusion increased both renal venous and urinary 6-keto-PGF1 alpha outflow. In contrast, renal arterial infusion of arachidonic acid (AA) or bradykinin (BK) increased renal venous 6-keto-PGF1 alpha outflow but had no effect on its urinary outflow. Both urinary and renal venous PGE2 outflows increased during AA or BK infusion. Ureteral stopped-flow studies revealed no postglomerular 6-keto-PGF1 alpha entry into tubular fluid. During renal arterial infusion of [3H]PGI2 and inulin, first-pass 3H clearance was 40% of inulin clearance; 35% of urinary 3H was 6-keto-PGF1 alpha, and two other urinary metabolites were found. During renal arterial infusion of [3H]6-keto-PGF1 alpha and inulin, first-pass 3H clearance was 150% of inulin clearance; 75% of urinary 3H was 6-keto-PGF1 alpha, and only one other metabolite was found. We conclude that in the dog PGE2 synthesized in the kidney enters directly into both the renal vascular and tubular compartments, but 6-keto-PGF1 alpha of renal origin enters directly into only the renal vascular compartment

  1. Renal Osteodystrophy

    Directory of Open Access Journals (Sweden)

    Aynur Metin Terzibaşoğlu

    2004-12-01

    Full Text Available Chronic renal insufficiency is a functional definition which is characterized by irreversible and progressive decreasing in renal functions. This impairment is in collaboration with glomeruler filtration rate and serum creatinine levels. Besides this, different grades of bone metabolism disorders develop in chronic renal insufficiency. Pathologic changes in bone tissue due to loss of renal paranchyme is interrelated with calcium, phosphorus vitamine-D and parathyroid hormone. Clinically we can see high turnover bone disease, low turnover bone disease, osteomalacia, osteosclerosis and osteoporosis in renal osteodystropy. In this article we aimed to review pathology of bone metabolism disorders due to chronic renal insufficiency, clinic aspects and treatment approaches briefly.

  2. Increased renal production of C-type natriuretic peptide (CNP) in patients with cirrhosis and functional renal failure

    DEFF Research Database (Denmark)

    Gülberg, V; Møller, S; Henriksen, Jens Henrik Sahl

    2000-01-01

    homeostasis. Therefore, the aim of the present study was to investigate the possible role of CNP in renal function disturbances in patients with cirrhosis of the liver. METHODS: Peripheral venous and urinary concentrations of CNP were determined in samples from 11 healthy controls, 20 cirrhotic patients...... with normal renal function (creatinine clearance 117 (8) ml/min), and 20 cirrhotic patients with impaired renal function (creatinine clearance 35 (4) ml/min). In a second protocol, arterial and renal venous plasma concentrations of CNP were determined in 37 patients with cirrhosis of the liver to estimate...... renal extraction ratios of CNP. A sensitive and specific radioimmunoassay was applied after solid phase extraction of samples. RESULTS: Plasma CNP was lower in cirrhotic patients with normal and impaired renal function than in controls (3.0 (0.4) and 2.7 (0.2) v. 4.2 (0.4) pg/ml, respectively; p

  3. A gamma camera method for quantitation of split renal function in children followed for vesicoureteric reflux

    International Nuclear Information System (INIS)

    Tamminen, T.E.; Riihimaeki, E.J.; Taehti, E.E.; Helsinki Univ. Central Hospital

    1978-01-01

    A method for quantitative estimation of split renal function using a computerized gamma camera system is described. 42 children and adolescents with existing or preexisting vesicouretric reflux and recurrent urinary tract infection were investigated. Total renal clearance of DTPA was calculated with a disapperarance curve derived from the largest extrarenal area in the field of view of a gamma camera with diverging collimator. Split renal function was estimated with the slopes of second phase renograms. The plasma disaapearance clearance of DTPA, calculated using one compartement model with two late blood samples, gave similar resusults with the clearance estimated from the body disappearance curves. The proportional planimetric renal parenchymal areas had good correlation with the split clearance estimated from renogram slopes. The method offers data on renal function and urinary tract dynamics which is very valuable in the follow-up of children with recurrent urinary tract infection and vesicoureteric reflux. (orig.) [de

  4. Determinação de cistatina C como marcador de função renal Cystatin C measurement as renal function marker

    Directory of Open Access Journals (Sweden)

    Letícia Aparecida Lopes Neri

    2010-12-01

    Full Text Available INTRODUÇÃO: A cistatina C sérica tem sido apontada como um marcador de filtração glomerular. OBJETIVO: Realizar a validação de um método específico e automatizado, a imunonefelometria, mensurando os níveis séricos de cistatina C por meio do nefelômetro da empresa Behring (BN II e correlacionar resultados obtidos entre pacientes transplantados. O ensaio perfaz o intervalo de referência de 0,23-7,25 mg/l. A imprecisão intra e interensaio foi de 8,73% e 5,38%, respectivamente. A recuperação analítica da cistatina C após adição de controle foi entre 86,7 % e 98% (média 92,3%. A estabilidade da cistatina C à temperatura ambiente, sob refrigeração e sob congelamento foi testada. A perda mais significativa foi encontrada nas amostras armazenadas à temperatura ambiente, em que foram perdidos até 10% da concentração inicial. Foi encontrado coeficiente de variação de 14,79% para sensibilidade analítica. Durante todo o processo foram comparados os resultados com o controle de qualidade e obtivemos bons resultados. Depois desses testes, nós comparamos as correlações em três grupos de pacientes transplantados renais sob diferentes esquemas de imunossupressão (n = 197 - azatioprina (n = 36, micofenolato mofetil (n = 131 e sirolimus (n = 30 - entre as equações de estimativa de filtração glomerular (Cockroft Gault, Nankivell e Modification of Diet in Renal Disease e cistatina C sérica ou creatinina sérica. CONCLUSÃO: O ensaio nefelométrico cistatina C pode perfeitamente ser adequado à nossa rotina laboratorial e as correlações entre creatinina sérica e as diferentes equações de estimativa de filtração glomerular são melhores do que quando comparamos as mesmas à cistatina C nos três grupos, independentemente da terapia imunossupressora utilizada.INTRODUCTION: Serum cystatin C has been identified as a glomerular filtration marker. OBJECTIVE: To validate immunonephelometry, a specific and automated method, by

  5. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  6. Reversal deterioration of renal function accompanied with primary hypothyrodism

    Directory of Open Access Journals (Sweden)

    Dragović Tamara

    2012-01-01

    Full Text Available Introduction. Hypothyroidism is often accompanied with decline of kidney function, or inability to maintain electrolyte balance. These changes are usually overlooked in everyday practice. Early recognition of this association eliminates unnecessary diagnostic procedures that postpone the adequate treatment. Case report. Two patients with elevated serum creatinine levels due to primary autoimmune hypothyroidism, with complete recovery of creatinine clearance after thyroid hormone substitution therapy are presented. The first patient was a young male whose laboratory tests suggested acute renal failure, and the delicate clinical presentation of reduced thyroid function. The second patient was an elderly woman with a history of a long-term signs and symptoms attributed to ageing, including the deterioration of renal function, with consequently delayed diagnosis of hypothyroidism. Conclusion. Serum thyrotropin and thyroxin levels measurement should be done in all cases of renal failure with undefined renal desease, even if the typical clinical presentation of hypothyroidism is absent. Thyroid hormone assays sholud also be performed in all patients with chronic kidney disease whose kidney function is rapidly worsening.

  7. Reversal deterioration of renal function accompanied with primary hypothyrodism.

    Science.gov (United States)

    Dragović, Tamara

    2012-02-01

    Hypothyroidism is often accompanied with decline of kidney function, or inability to maintain electrolyte balance. These changes are usually overlooked in everyday practice. Early recognition of this association eliminates unnecessary diagnostic procedures that postpone the adequate treatment. Two patients with elevated serum creatinine levels due to primary autoimmune hypothyroidism, with complete recovery of creatinine clearance after thyroid hormone substitution therapy are presented. The first patient was a young male whose laboratory tests suggested acute renal failure, and the delicate clinical presentation of reduced thyroid function. The second patient was an elderly woman with a history of a long-term signs and symptoms attributed to ageing, including the deterioration of renal function, with consequently delayed diagnosis of hypothyroidism. Serum thyrotropin and thyroxin levels measurement should be done in all cases of renal failure with undefined renal desease, even if the typical clinical presentation of hypothyroidism is absent. Thyroid hormone assays sholud also be performed in all patients with chronic kidney disease whose kidney function is rapidly worsening.

  8. Reproducibility of MRI renal artery blood flow and BOLD measurements in patients with chronic kidney disease and healthy controls.

    Science.gov (United States)

    Khatir, Dinah S; Pedersen, Michael; Jespersen, Bente; Buus, Niels H

    2014-11-01

    Determine the reproducibility of renal artery blood flow (RABF) and blood-oxygenation level dependent (R2 *) in patients with chronic kidney disease (CKD) and healthy controls. RABF and R2 * were measured in 11 CKD patients and 9 controls twice with 1- to 2-week interval. R2 * in the cortex and medulla were determined after breathing atmospheric air and 100% oxygen. Reproducibility was evaluated by coefficients of variation (CV), limits of agreements and intra-class coefficient calculated by variance components by maximum likelihood modeling. Single-kidney RABF (mL/min) for patients was: 170 ± 130 and 186 ± 137, and for controls: 365 ± 119 and 361 ± 107 (P Renal cortical R2 * was: 13.6 ± 0.9 and 13.5 ± 1.2 in patients (CV = 8.0%), and 13.8 ± 1.6 and 14.0 ± 1.5 in controls (CV = 5.6%), while medullary R2 *(s(-1) ) was: 26.9 ± 2.0 and 27.0 ± 4.0 (CV = 8.0%) in patients, and 26.0 ± 2.4 and 26.1 ± 2.1 (CV = 3.6%) in controls, for first and second scans, respectively. In both groups R2 * in medulla decreased after breathing 100% oxygen. The reproducibility was high for both RABF and R2 * in patients and controls, particularly in the cortex. Inhalation of 100% oxygen reduced medullary R2 *. © 2013 Wiley Periodicals, Inc.

  9. Aldosterone dysregulation with aging predicts renal vascular function and cardiovascular risk.

    Science.gov (United States)

    Brown, Jenifer M; Underwood, Patricia C; Ferri, Claudio; Hopkins, Paul N; Williams, Gordon H; Adler, Gail K; Vaidya, Anand

    2014-06-01

    Aging and abnormal aldosterone regulation are both associated with vascular disease. We hypothesized that aldosterone dysregulation influences the age-related risk of renal vascular and cardiovascular disease. We conducted an analysis of 562 subjects who underwent detailed investigations under conditions of liberal and restricted dietary sodium intake (1124 visits) in the General Clinical Research Center. Aldosterone regulation was characterized by the ratio of maximal suppression to stimulation (supine serum aldosterone on a liberal sodium diet divided by the same measure on a restricted sodium diet). We previously demonstrated that higher levels of this Sodium-modulated Aldosterone Suppression-Stimulation Index (SASSI) indicate greater aldosterone dysregulation. Renal plasma flow (RPF) was determined via p-aminohippurate clearance to assess basal renal hemodynamics and the renal vascular responses to dietary sodium manipulation and angiotensin II infusion. Cardiovascular risk was calculated using the Framingham Risk Score. In univariate linear regression, older age (β=-4.60; Page and SASSI, where the inverse relationship between SASSI and RPF was most apparent with older age (Page may interact to mediate renal vascular disease. Our findings suggest that the combination of aldosterone dysregulation and renal vascular dysfunction could additively increase the risk of future cardiovascular outcomes; therefore, aldosterone dysregulation may represent a modifiable mechanism of age-related vascular disease.

  10. Renal venogram

    Science.gov (United States)

    ... be black. Other structures will be shades of gray. Veins are not normally seen in an x- ... Venogram - kidney; Renal vein thrombosis - venogram Images Kidney anatomy Kidney - blood and urine flow Renal veins References ...

  11. A role for the organic anion transporter OAT3 in renal creatinine secretion in mice

    Science.gov (United States)

    Eraly, Satish A.; Rao, Satish Ramachandra; Gerasimova, Maria; Rose, Michael; Nagle, Megha; Anzai, Naohiko; Smith, Travis; Sharma, Kumar; Nigam, Sanjay K.; Rieg, Timo

    2012-01-01

    Tubular secretion of the organic cation, creatinine, limits its value as a marker of glomerular filtration rate (GFR) but the molecular determinants of this pathway are unclear. The organic anion transporters, OAT1 and OAT3, are expressed on the basolateral membrane of the proximal tubule and transport organic anions but also neutral compounds and cations. Here, we demonstrate specific uptake of creatinine into mouse mOat1- and mOat3-microinjected Xenopus laevis oocytes at a concentration of 10 μM (i.e., similar to physiological plasma levels), which was inhibited by both probenecid and cimetidine, prototypical competitive inhibitors of organic anion and cation transporters, respectively. Renal creatinine clearance was consistently greater than inulin clearance (as a measure of GFR) in wild-type (WT) mice but not in mice lacking OAT1 (Oat1−/−) and OAT3 (Oat3−/−). WT mice presented renal creatinine net secretion (0.23 ± 0.03 μg/min) which represented 45 ± 6% of total renal creatinine excretion. Mean values for renal creatinine net secretion and renal creatinine secretion fraction were not different from zero in Oat1−/− (−0.03 ± 0.10 μg/min; −3 ± 18%) and Oat3−/− (0.01 ± 0.06 μg/min; −6 ± 19%), with greater variability in Oat1−/−. Expression of OAT3 protein in the renal membranes of Oat1−/− mice was reduced to ∼6% of WT levels, and that of OAT1 in Oat3−/− mice to ∼60%, possibly as a consequence of the genes for Oat1 and Oat3 having adjacent chromosomal locations. Plasma creatinine concentrations of Oat3−/− were elevated in clearance studies under anesthesia but not following brief isoflurane anesthesia, indicating that the former condition enhanced the quantitative contribution of OAT3 for renal creatinine secretion. The results are consistent with a contribution of OAT3 and possibly OAT1 to renal creatinine secretion in mice. PMID:22338083

  12. Severe hypothyroidism masquerading as renal impairment

    DEFF Research Database (Denmark)

    Bistrup, C; Jensen, Dorte Møller; Kvetny, J

    1996-01-01

    creatinine clearance and proteinuria, polymyositis with secondary glomerulopathy was suspected. Meanwhile, biopsies from skin, muscle, and kidney were normal. All symptoms disappeared 3 months after thyroid replacement therapy was initiated. S-TSH should be considered when evaluating patients with renal...

  13. Associations of Conventional Echocardiographic Measures with Incident Heart Failure and Mortality: The Chronic Renal Insufficiency Cohort.

    Science.gov (United States)

    Dubin, Ruth F; Deo, Rajat; Bansal, Nisha; Anderson, Amanda H; Yang, Peter; Go, Alan S; Keane, Martin; Townsend, Ray; Porter, Anna; Budoff, Matthew; Malik, Shaista; He, Jiang; Rahman, Mahboob; Wright, Jackson; Cappola, Thomas; Kallem, Radhakrishna; Roy, Jason; Sha, Daohang; Shlipak, Michael G

    2017-01-06

    Heart failure is the most frequent cardiac complication of CKD. Left ventricular hypertrophy is common and develops early in CKD, but studies have not adequately evaluated the association of left ventricular mass index with heart failure incidence among men and women with CKD. We evaluated echocardiograms of 2567 participants without self-reported heart failure enrolled in the Chronic Renal Insufficiency Cohort Study. Two-dimensional echocardiograms were performed at the year 1 study visit and interpreted at a central core laboratory. Left ventricular mass index was calculated using the linear method, indexed to height 2.7 , and analyzed using sex-specific quartiles. The primary outcomes of incident heart failure and all-cause mortality were adjudicated over a median of 6.6 (interquartile range, 5.7-7.6) years. Among 2567 participants, 45% were women, and 54% were nonwhite race; mean (SD) age was 59±11 years old, and mean eGFR was 44±17 ml/min per 1.73 m 2 . During a median follow-up period of 6.6 years, 262 participants developed heart failure, and 470 participants died. Compared with participants in the first quartile of left ventricular mass index, those in the highest quartile had higher rates of incident heart failure (hazard ratio, 3.96; 95% confidence interval, 1.96 to 8.02) and mortality (hazard ratio, 1.86; 95% confidence interval, 1.22 to 2.85), even after adjustment for B-type natriuretic peptide, troponin T, mineral metabolism markers, and other cardiovascular disease risk factors. Those in the lowest quartile of ejection fraction had higher rates of incident heart failure (hazard ratio, 3.01; 95% confidence interval, 1.94 to 4.67) but similar mortality rates (hazard ratio, 1.18; 95% confidence interval, 0.89 to 1.57) compared with those in the highest quartile. Diastolic dysfunction was not significantly associated with heart failure or death. Among persons with CKD and without history of cardiovascular disease, left ventricular mass index is

  14. Measuring the quality of renal care: things to keep in mind when selecting and using quality indicators.

    Science.gov (United States)

    van der Veer, Sabine N; van Biesen, Wim; Couchoud, Cécile; Tomson, Charles R V; Jager, Kitty J

    2014-08-01

    This educational paper discusses a variety of indicators that can be used to measure the quality of care in renal medicine. Based on what aspect of care they reflect, indicators can be grouped into four main categories: structure, process, surrogate outcome and outcome indicators. Each category has its own advantages and disadvantages, and we give some pointers on how to balance these pros and cons while taking into account the aim of the measurement initiative. Especially within initiatives that link payment or reputation to indicator measurement, this balancing should be done with utmost care to avoid potential, unintended consequences. Furthermore, we suggest consideration of (i) a causal chain-i.e. subsequent aspects of care connected by evidence-based links-as a starting point for composing a performance indicator set and (ii) adequate case-mix adjustment, not only of (surrogate) outcomes, but also of process indicators in order to obtain fair comparisons between facilities and within facilities over time. © The Author 2013. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  15. The value of the renal resistive index in the measurement of renal perfusion before and after extracorporal shock wave lithotripsy in correlation to the scintigraphy, to the magnetic resonance perfusion imaging and to big-endothelin values

    International Nuclear Information System (INIS)

    Palwein-Prettner, L.

    1999-07-01

    Purpose: the goal of this study was to evaluate effects of extracorporeal shock wave lithotripsy (ESWL) on the renal perfusion using the resistive index (RI), perfusion scintigraphy, magnetic resonance (MR) perfusion imaging and plasma big-endothelin (big-ET-1) values. Method/materials: In 21 patients divided in 3 age-groups the RI was measured before and 1,3,6 and 24 hours after ESWL. Big-ET-1, a potent vasoconstrictor peptid was correlated with the RI values. The RI and Big-ET-1 results was compared to the results of the MR perfusion imaging and the scintigraphy, the gold-standard method. Results: The RI of the treated kidneys increased significantly from 0,64±0,05 to 0,72±0,08 after the ESWL (p<0,001) and in the untreated kidneys from 0,63±0,05 to 0,68±0,09 (p=0,003). The hightest age group shows the most significant increase. The Big-ET-values also increased only in this age group significantly from 0,78±0,24 fmol/l to 1,58±0,52 fmol/l. In the scintigraphy the decrease of the renal plasma flow (RPF) in this age group was most significant. The MR perfusion Imaging shows in all age groups significant decrease (p<0,001). Conclusion: we conclude that the ESWL causes considerable renal parenchymal damage only in the elderly patients. The following changes in renal perfusion were measured very sensitively with the RI which had a good correlation to the results of the perfusion scintigraphy and the MR perfusion imaging.